WorldWideScience

Sample records for sequential time points

  1. The relative timing between eye and hand rapid sequential pointing is affected by time pressure, but not by advance knowledge

    NARCIS (Netherlands)

    Deconinck, F.; van Polanen, V.; Savelsbergh, G.J.P.; Bennett, S.

    2011-01-01

    The present study examined the effect of timing constraints and advance knowledge on eye-hand coordination strategy in a sequential pointing task. Participants were required to point at two successively appearing targets on a screen while the inter-stimulus interval (ISI) and the trial order were

  2. Sequential function approximation on arbitrarily distributed point sets

    Science.gov (United States)

    Wu, Kailiang; Xiu, Dongbin

    2018-02-01

    We present a randomized iterative method for approximating unknown function sequentially on arbitrary point set. The method is based on a recently developed sequential approximation (SA) method, which approximates a target function using one data point at each step and avoids matrix operations. The focus of this paper is on data sets with highly irregular distribution of the points. We present a nearest neighbor replacement (NNR) algorithm, which allows one to sample the irregular data sets in a near optimal manner. We provide mathematical justification and error estimates for the NNR algorithm. Extensive numerical examples are also presented to demonstrate that the NNR algorithm can deliver satisfactory convergence for the SA method on data sets with high irregularity in their point distributions.

  3. Sequential Change-Point Detection via Online Convex Optimization

    Directory of Open Access Journals (Sweden)

    Yang Cao

    2018-02-01

    Full Text Available Sequential change-point detection when the distribution parameters are unknown is a fundamental problem in statistics and machine learning. When the post-change parameters are unknown, we consider a set of detection procedures based on sequential likelihood ratios with non-anticipating estimators constructed using online convex optimization algorithms such as online mirror descent, which provides a more versatile approach to tackling complex situations where recursive maximum likelihood estimators cannot be found. When the underlying distributions belong to a exponential family and the estimators satisfy the logarithm regret property, we show that this approach is nearly second-order asymptotically optimal. This means that the upper bound for the false alarm rate of the algorithm (measured by the average-run-length meets the lower bound asymptotically up to a log-log factor when the threshold tends to infinity. Our proof is achieved by making a connection between sequential change-point and online convex optimization and leveraging the logarithmic regret bound property of online mirror descent algorithm. Numerical and real data examples validate our theory.

  4. THE DEVELOPMENT OF SPECIAL SEQUENTIALLY-TIMED

    Directory of Open Access Journals (Sweden)

    Stanislav LICHOROBIEC

    2016-06-01

    Full Text Available This article documents the development of the noninvasive use of explosives during the destruction of ice mass in river flows. The system of special sequentially-timed charges utilizes the increase in efficiency of cutting charges by covering them with bags filled with water, while simultaneously increasing the effect of the entire system of timed charges. Timing, spatial combinations during placement, and the linking of these charges results in the loosening of ice barriers on a frozen waterway, while at the same time regulating the size of the ice fragments. The developed charges will increase the operability and safety of IRS units.

  5. Time scale of random sequential adsorption.

    Science.gov (United States)

    Erban, Radek; Chapman, S Jonathan

    2007-04-01

    A simple multiscale approach to the diffusion-driven adsorption from a solution to a solid surface is presented. The model combines two important features of the adsorption process: (i) The kinetics of the chemical reaction between adsorbing molecules and the surface and (ii) geometrical constraints on the surface made by molecules which are already adsorbed. The process (i) is modeled in a diffusion-driven context, i.e., the conditional probability of adsorbing a molecule provided that the molecule hits the surface is related to the macroscopic surface reaction rate. The geometrical constraint (ii) is modeled using random sequential adsorption (RSA), which is the sequential addition of molecules at random positions on a surface; one attempt to attach a molecule is made per one RSA simulation time step. By coupling RSA with the diffusion of molecules in the solution above the surface the RSA simulation time step is related to the real physical time. The method is illustrated on a model of chemisorption of reactive polymers to a virus surface.

  6. Evaluation of sequential images for photogrammetrically point determination

    Science.gov (United States)

    Kowalczyk, M.

    2011-12-01

    Close range photogrammetry encounters many problems with reconstruction of objects three-dimensional shape. Relative orientation parameters of taken photos makes usually key role leading to right solution of this problem. Automation of technology process is hardly performed due to recorded scene complexity and configuration of camera positions. This configuration makes the process of joining photos into one set usually impossible automatically. Application of camcorder is the solution widely proposed in literature for support in 3D models creation. Main advantages of this tool are connected with large number of recorded images and camera positions. Exterior orientation changes barely between two neighboring frames. Those features of film sequence gives possibilities for creating models with basic algorithms, working faster and more robust, than with remotely taken photos. The first part of this paper presents results of experiments determining interior orientation parameters of some sets of frames, presenting three-dimensional test field. This section describes calibration repeatability of film frames taken from camcorder. It is important due to stability of interior camera geometric parameters. Parametric model of systematical errors was applied for correcting images. Afterwards a short film of the same test field had been taken for determination of check points group. This part has been done for controlling purposes of camera application in measurement tasks. Finally there are presented some results of experiments which compare determination of recorded object points in 3D space. In common digital photogrammetry, where separate photos are used, first levels of image pyramids are taken to connect with feature based matching. This complicated process creates a lot of emergencies, which can produce false detections of image similarities. In case of digital film camera, authors of publications avoid this dangerous step, going straightly to area based matching, aiming

  7. Sequential and Biomechanical Factors Constrain Timing and Motion in Tapping

    NARCIS (Netherlands)

    Loehr, J.D.; Palmer, C.

    2009-01-01

    The authors examined how timing accuracy in tapping sequences is influenced by sequential effects of preceding finger movements and biomechanical interdependencies among fingers. Skilled pianists tapped Sequences at 3 rates; in each sequence, a finger whose motion was more or less independent of

  8. Zero Point of Historical Time

    Directory of Open Access Journals (Sweden)

    R.S. Khakimov

    2014-02-01

    Full Text Available Historical studies are based on the assumption that there is a reference-starting point of the space-time – the Zero point of coordinate system. Due to the bifurcation in the Zero Point, the course of social processes changes sharply and the probabilistic causality replaces the deterministic one. For this reason, changes occur in the structure of social relations and statehood form as well as in the course of the ethnic processes. In such a way emerges a new discourse of the national behavior. With regard to the history of the Tatars and Tatarstan, such bifurcation points occurred in the periods of the formation: 1 of the Turkic Khaganate, which began to exist from the 6th century onward and became a qualitatively new State system that reformatted old elements in the new matrix introducing a new discourse of behavior; 2 of the Volga-Kama Bulgaria, where the rivers (Kama, Volga, Vyatka became the most important trade routes determining the singularity of this State. Here the nomadic culture was connected with the settled one and Islam became the official religion in 922; 3 and of the Golden Hordе, a powerful State with a remarkable system of communication, migration of huge human resources for thousands of kilometers, and extensive trade, that caused severe “mutations” in the ethnic terms and a huge mixing of ethnic groups. Given the dwelling space of Tatar population and its evolution within Russia, it can be argued that the Zero point of Tatar history, which conveyed the cultural invariants until today, begins in the Golden Horde. Neither in the Turkic khaganate nor in the Bulgar State, but namely in the Golden Horde. Despite the radical changes, the Russian Empire failed to transform the Tatars in the Russians. Therefore, contemporary Tatars preserved the Golden Horde tradition as a cultural invariant.

  9. A continuous-time neural model for sequential action.

    Science.gov (United States)

    Kachergis, George; Wyatte, Dean; O'Reilly, Randall C; de Kleijn, Roy; Hommel, Bernhard

    2014-11-05

    Action selection, planning and execution are continuous processes that evolve over time, responding to perceptual feedback as well as evolving top-down constraints. Existing models of routine sequential action (e.g. coffee- or pancake-making) generally fall into one of two classes: hierarchical models that include hand-built task representations, or heterarchical models that must learn to represent hierarchy via temporal context, but thus far lack goal-orientedness. We present a biologically motivated model of the latter class that, because it is situated in the Leabra neural architecture, affords an opportunity to include both unsupervised and goal-directed learning mechanisms. Moreover, we embed this neurocomputational model in the theoretical framework of the theory of event coding (TEC), which posits that actions and perceptions share a common representation with bidirectional associations between the two. Thus, in this view, not only does perception select actions (along with task context), but actions are also used to generate perceptions (i.e. intended effects). We propose a neural model that implements TEC to carry out sequential action control in hierarchically structured tasks such as coffee-making. Unlike traditional feedforward discrete-time neural network models, which use static percepts to generate static outputs, our biological model accepts continuous-time inputs and likewise generates non-stationary outputs, making short-timescale dynamic predictions. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  10. Sequentially firing neurons confer flexible timing in neural pattern generators

    International Nuclear Information System (INIS)

    Urban, Alexander; Ermentrout, Bard

    2011-01-01

    Neuronal networks exhibit a variety of complex spatiotemporal patterns that include sequential activity, synchrony, and wavelike dynamics. Inhibition is the primary means through which such patterns are implemented. This behavior is dependent on both the intrinsic dynamics of the individual neurons as well as the connectivity patterns. Many neural circuits consist of networks of smaller subcircuits (motifs) that are coupled together to form the larger system. In this paper, we consider a particularly simple motif, comprising purely inhibitory interactions, which generates sequential periodic dynamics. We first describe the dynamics of the single motif both for general balanced coupling (all cells receive the same number and strength of inputs) and then for a specific class of balanced networks: circulant systems. We couple these motifs together to form larger networks. We use the theory of weak coupling to derive phase models which, themselves, have a certain structure and symmetry. We show that this structure endows the coupled system with the ability to produce arbitrary timing relationships between symmetrically coupled motifs and that the phase relationships are robust over a wide range of frequencies. The theory is applicable to many other systems in biology and physics.

  11. "Time sequential high dose of Cytarabine in acute myelocytic leukemia "

    Directory of Open Access Journals (Sweden)

    Ghavamzadeh A

    2003-05-01

    Full Text Available Given preliminary evidence of timed, sequential chemotherapy of high dose cytosine arabinoside the current study was initiated to assess the side effects and efficacy of this regimen in patients with newly acute myelocytic leukemia (AML. Nineteen adults who referred to Hematology-Oncology and Bone Marrow Transplantation (BMT research center of Tehran University of Medical Sciences were enrolled in a trial from Aug 1999 to Nov 2000. All patients had a Karnofski classification above 60%. At this time induction therapy consisted of daunorubicin or idarubicin given at a dose of 60 mg/m² and 12 mg/m² IV respectively on days 1-3, and cytarabine (Ara-C 100 mg/m² intravenously by continuous infusion on days 1-7, followed by Ara-C 1000 mg/m² given on day 8-10 every 12 hours by IV infusion. Consolidation therapy started after 35th day. Of 19 fully evaluable patients, 10 patients achieved a complete remission, whereas 36.6% patients succumbed to death due to regeneration failure. The clinical data show that the overall survival rate from diagnosis 55.5% (95% CI, 30.8-78.5 at 6 months for the entire cohort of the patients. Disease free survival is also 50% (95% CI, 26-74. Mean duration of death due to treatment was 20 days (range 17-29 after beginning the regimen. Presenting WBC counts, French-American-British (FAB classification, sex and age were not useful prognostic variables. Fever, diarrhea, nausea and vomiting and GI hemorrhage were seen in 19, 6, 4, 7 patients respectively. It seems the 3+7+3 regimen is a promising approach for the AML patients regarding to high complete remission rate, but more supportive care should be considered. Furthermore any, benefit in long-term outcome can’t be determined regardless to the choice of post remission therapy (e.g., GCSF, appropriate antibiotics and etc.

  12. Improving multiple-point-based a priori models for inverse problems by combining Sequential Simulation with the Frequency Matching Method

    DEFF Research Database (Denmark)

    Cordua, Knud Skou; Hansen, Thomas Mejer; Lange, Katrine

    In order to move beyond simplified covariance based a priori models, which are typically used for inverse problems, more complex multiple-point-based a priori models have to be considered. By means of marginal probability distributions ‘learned’ from a training image, sequential simulation has...... proven to be an efficient way of obtaining multiple realizations that honor the same multiple-point statistics as the training image. The frequency matching method provides an alternative way of formulating multiple-point-based a priori models. In this strategy the pattern frequency distributions (i.......e. marginals) of the training image and a subsurface model are matched in order to obtain a solution with the same multiple-point statistics as the training image. Sequential Gibbs sampling is a simulation strategy that provides an efficient way of applying sequential simulation based algorithms as a priori...

  13. Patient specific dynamic geometric models from sequential volumetric time series image data.

    Science.gov (United States)

    Cameron, B M; Robb, R A

    2004-01-01

    Generating patient specific dynamic models is complicated by the complexity of the motion intrinsic and extrinsic to the anatomic structures being modeled. Using a physics-based sequentially deforming algorithm, an anatomically accurate dynamic four-dimensional model can be created from a sequence of 3-D volumetric time series data sets. While such algorithms may accurately track the cyclic non-linear motion of the heart, they generally fail to accurately track extrinsic structural and non-cyclic motion. To accurately model these motions, we have modified a physics-based deformation algorithm to use a meta-surface defining the temporal and spatial maxima of the anatomic structure as the base reference surface. A mass-spring physics-based deformable model, which can expand or shrink with the local intrinsic motion, is applied to the metasurface, deforming this base reference surface to the volumetric data at each time point. As the meta-surface encompasses the temporal maxima of the structure, any extrinsic motion is inherently encoded into the base reference surface and allows the computation of the time point surfaces to be performed in parallel. The resultant 4-D model can be interactively transformed and viewed from different angles, showing the spatial and temporal motion of the anatomic structure. Using texture maps and per-vertex coloring, additional data such as physiological and/or biomechanical variables (e.g., mapping electrical activation sequences onto contracting myocardial surfaces) can be associated with the dynamic model, producing a 5-D model. For acquisition systems that may capture only limited time series data (e.g., only images at end-diastole/end-systole or inhalation/exhalation), this algorithm can provide useful interpolated surfaces between the time points. Such models help minimize the number of time points required to usefully depict the motion of anatomic structures for quantitative assessment of regional dynamics.

  14. An accurate approximate solution of optimal sequential age replacement policy for a finite-time horizon

    International Nuclear Information System (INIS)

    Jiang, R.

    2009-01-01

    It is difficult to find the optimal solution of the sequential age replacement policy for a finite-time horizon. This paper presents an accurate approximation to find an approximate optimal solution of the sequential replacement policy. The proposed approximation is computationally simple and suitable for any failure distribution. Their accuracy is illustrated by two examples. Based on the approximate solution, an approximate estimate for the total cost is derived.

  15. Sequential specification of time-aware stream processing applications

    NARCIS (Netherlands)

    Geuns, S.J.; Hausmans, J.P.H.M.; Bekooij, Marco Jan Gerrit

    Automatic parallelization of Nested Loop Programs (NLPs) is an attractive method to create embedded real-time stream processing applications for multi-core systems. However, the description and parallelization of applications with a time dependent functional behavior has not been considered in NLPs.

  16. Unsupervised land cover change detection: meaningful sequential time series analysis

    CSIR Research Space (South Africa)

    Salmon, BP

    2011-06-01

    Full Text Available An automated land cover change detection method is proposed that uses coarse spatial resolution hyper-temporal earth observation satellite time series data. The study compared three different unsupervised clustering approaches that operate on short...

  17. Effects of neostriatal 6-OHDA lesion on performance in a rat sequential reaction time task.

    Science.gov (United States)

    Domenger, D; Schwarting, R K W

    2008-10-31

    Work in humans and monkeys has provided evidence that the basal ganglia, and the neurotransmitter dopamine therein, play an important role for sequential learning and performance. Compared to primates, experimental work in rodents is rather sparse, largely due to the fact that tasks comparable to the human ones, especially serial reaction time tasks (SRTT), had been lacking until recently. We have developed a rat model of the SRTT, which allows to study neural correlates of sequential performance and motor sequence execution. Here, we report the effects of dopaminergic neostriatal lesions, performed using bilateral 6-hydroxydopamine injections, on performance of well-trained rats tested in our SRTT. Sequential behavior was measured in two ways: for one, the effects of small violations of otherwise well trained sequences were examined as a measure of attention and automation. Secondly, sequential versus random performance was compared as a measure of sequential learning. Neurochemically, the lesions led to sub-total dopamine depletions in the neostriatum, which ranged around 60% in the lateral, and around 40% in the medial neostriatum. These lesions led to a general instrumental impairment in terms of reduced speed (response latencies) and response rate, and these deficits were correlated with the degree of striatal dopamine loss. Furthermore, the violation test indicated that the lesion group conducted less automated responses. The comparison of random versus sequential responding showed that the lesion group did not retain its superior sequential performance in terms of speed, whereas they did in terms of accuracy. Also, rats with lesions did not improve further in overall performance as compared to pre-lesion values, whereas controls did. These results support previous results that neostriatal dopamine is involved in instrumental behaviour in general. Also, these lesions are not sufficient to completely abolish sequential performance, at least when acquired

  18. Impact of sequential disorder on the scaling behavior of airplane boarding time

    Science.gov (United States)

    Baek, Yongjoo; Ha, Meesoon; Jeong, Hawoong

    2013-05-01

    Airplane boarding process is an example where disorder properties of the system are relevant to the emergence of universality classes. Based on a simple model, we present a systematic analysis of finite-size effects in boarding time, and propose a comprehensive view of the role of sequential disorder in the scaling behavior of boarding time against the plane size. Using numerical simulations and mathematical arguments, we find how the scaling behavior depends on the number of seat columns and the range of sequential disorder. Our results show that new scaling exponents can arise as disorder is localized to varying extents.

  19. Radio controlled detonators and sequential real time blast applications

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, T.; Laboz, J.M. [Delta Caps International, Nice (France)

    1995-12-31

    Among the numerous technical evolutions in the blasting environment the authors are going to describe below the concept of electronic detonator sequenced by radio waves, and also its numerous applications. Three major technologies are used in the initiation environment: fused-initiated detonators; electric detonators; and non-electric detonators. The last two technologies were made available under multiple variants. Two major innovations are going to substantially change the way traditional detonators operate: pyrotechnic delays are replaced by electronic delays (greater accuracy); and triggering orders, passing through a cable, is now replaced by radio-waves transmission (possibility to do real time delay pattern). Such a new product provided all the features offered by current detonators, but also allows mastering specific cases that were difficult to control with the current technology, such as: vibration control; underground blast; and building demolition.

  20. Real-time skin feature identification in a time-sequential video stream

    Science.gov (United States)

    Kramberger, Iztok

    2005-04-01

    Skin color can be an important feature when tracking skin-colored objects. Particularly this is the case for computer-vision-based human-computer interfaces (HCI). Humans have a highly developed feeling of space and, therefore, it is reasonable to support this within intelligent HCI, where the importance of augmented reality can be foreseen. Joining human-like interaction techniques within multimodal HCI could, or will, gain a feature for modern mobile telecommunication devices. On the other hand, real-time processing plays an important role in achieving more natural and physically intuitive ways of human-machine interaction. The main scope of this work is the development of a stereoscopic computer-vision hardware-accelerated framework for real-time skin feature identification in the sense of a single-pass image segmentation process. The hardware-accelerated preprocessing stage is presented with the purpose of color and spatial filtering, where the skin color model within the hue-saturation-value (HSV) color space is given with a polyhedron of threshold values representing the basis of the filter model. An adaptive filter management unit is suggested to achieve better segmentation results. This enables the adoption of filter parameters to the current scene conditions in an adaptive way. Implementation of the suggested hardware structure is given at the level of filed programmable system level integrated circuit (FPSLIC) devices using an embedded microcontroller as their main feature. A stereoscopic clue is achieved using a time-sequential video stream, but this shows no difference for real-time processing requirements in terms of hardware complexity. The experimental results for the hardware-accelerated preprocessing stage are given by efficiency estimation of the presented hardware structure using a simple motion-detection algorithm based on a binary function.

  1. A meta-analysis of response-time tests of the sequential two-systems model of moral judgment.

    Science.gov (United States)

    Baron, Jonathan; Gürçay, Burcu

    2017-05-01

    The (generalized) sequential two-system ("default interventionist") model of utilitarian moral judgment predicts that utilitarian responses often arise from a system-two correction of system-one deontological intuitions. Response-time (RT) results that seem to support this model are usually explained by the fact that low-probability responses have longer RTs. Following earlier results, we predicted response probability from each subject's tendency to make utilitarian responses (A, "Ability") and each dilemma's tendency to elicit deontological responses (D, "Difficulty"), estimated from a Rasch model. At the point where A = D, the two responses are equally likely, so probability effects cannot account for any RT differences between them. The sequential two-system model still predicts that many of the utilitarian responses made at this point will result from system-two corrections of system-one intuitions, hence should take longer. However, when A = D, RT for the two responses was the same, contradicting the sequential model. Here we report a meta-analysis of 26 data sets, which replicated the earlier results of no RT difference overall at the point where A = D. The data sets used three different kinds of moral judgment items, and the RT equality at the point where A = D held for all three. In addition, we found that RT increased with A-D. This result holds for subjects (characterized by Ability) but not for items (characterized by Difficulty). We explain the main features of this unanticipated effect, and of the main results, with a drift-diffusion model.

  2. Enhancing sequential time perception and storytelling ability of deaf and hard of hearing children.

    Science.gov (United States)

    Ingber, Sara; Eden, Sigal

    2011-01-01

    A 3-month intervention was conducted to enhance the sequential time perception and storytelling ability of young children with hearing loss. The children were trained to arrange pictorial episodes of temporal scripts and tell the stories they created. Participants (N = 34, aged 4-7 years) were divided into 2 groups based on whether their spoken-language gap was more or less than 1 year compared to age norms. They completed A. Kaufman and N. Kaufman's (1983) picture series subtest and Guralnik's (1982) storytelling test at pretest and posttest. Measures demonstrated significant improvement in sequential time and storytelling achievement postintervention. Three of the examined demographic variables revealed correlations: Participants with genetic etiology showed greater improvement in time sequencing and storytelling than participants with unknown etiology; early onset of treatment correlated with better achievement in time sequencing; cochlear implant users showed greater storytelling improvement than hearing aid users.

  3. Optimal time points sampling in pathway modelling.

    Science.gov (United States)

    Hu, Shiyan

    2004-01-01

    Modelling cellular dynamics based on experimental data is at the heart of system biology. Considerable progress has been made to dynamic pathway modelling as well as the related parameter estimation. However, few of them gives consideration for the issue of optimal sampling time selection for parameter estimation. Time course experiments in molecular biology rarely produce large and accurate data sets and the experiments involved are usually time consuming and expensive. Therefore, to approximate parameters for models with only few available sampling data is of significant practical value. For signal transduction, the sampling intervals are usually not evenly distributed and are based on heuristics. In the paper, we investigate an approach to guide the process of selecting time points in an optimal way to minimize the variance of parameter estimates. In the method, we first formulate the problem to a nonlinear constrained optimization problem by maximum likelihood estimation. We then modify and apply a quantum-inspired evolutionary algorithm, which combines the advantages of both quantum computing and evolutionary computing, to solve the optimization problem. The new algorithm does not suffer from the morass of selecting good initial values and being stuck into local optimum as usually accompanied with the conventional numerical optimization techniques. The simulation results indicate the soundness of the new method.

  4. Three-point method for measuring the geometric error components of linear and rotary axes based on sequential multilateration

    International Nuclear Information System (INIS)

    Zhang, Zhenjiu; Hu, Hong

    2013-01-01

    The linear and rotary axes are fundamental parts of multi-axis machine tools. The geometric error components of the axes must be measured for motion error compensation to improve the accuracy of the machine tools. In this paper, a simple method named the three point method is proposed to measure the geometric error of the linear and rotary axes of the machine tools using a laser tracker. A sequential multilateration method, where uncertainty is verified through simulation, is applied to measure the 3D coordinates. Three noncollinear points fixed on the stage of each axis are selected. The coordinates of these points are simultaneously measured using a laser tracker to obtain their volumetric errors by comparing these coordinates with ideal values. Numerous equations can be established using the geometric error models of each axis. The geometric error components can be obtained by solving these equations. The validity of the proposed method is verified through a series of experiments. The results indicate that the proposed method can measure the geometric error of the axes to compensate for the errors in multi-axis machine tools.

  5. Robust real-time pattern matching using bayesian sequential hypothesis testing.

    Science.gov (United States)

    Pele, Ofir; Werman, Michael

    2008-08-01

    This paper describes a method for robust real time pattern matching. We first introduce a family of image distance measures, the "Image Hamming Distance Family". Members of this family are robust to occlusion, small geometrical transforms, light changes and non-rigid deformations. We then present a novel Bayesian framework for sequential hypothesis testing on finite populations. Based on this framework, we design an optimal rejection/acceptance sampling algorithm. This algorithm quickly determines whether two images are similar with respect to a member of the Image Hamming Distance Family. We also present a fast framework that designs a near-optimal sampling algorithm. Extensive experimental results show that the sequential sampling algorithm performance is excellent. Implemented on a Pentium 4 3 GHz processor, detection of a pattern with 2197 pixels, in 640 x 480 pixel frames, where in each frame the pattern rotated and was highly occluded, proceeds at only 0.022 seconds per frame.

  6. The timing of control signals underlying fast point-to-point arm movements.

    Science.gov (United States)

    Ghafouri, M; Feldman, A G

    2001-04-01

    on the handle, or computed with equations of motion. In some trials, an electromagnetic brake prevented movements. In such movements, the hand force and joint torques reached a steady state after a time that was much smaller than the movement duration in unobstructed movements and was approximately equal to the time to peak velocity (mean difference hypothesis that, in unobstructed movements, the IC shifts and resulting shifts in the EP end approximately at peak velocity. In other words, during the latter part of the movement, the control signals responsible for the equilibrium shift remained constant, and the movement was driven by the arm inertial, viscous and elastic forces produced by the muscle-reflex system. Fast movements may thus be completed without continuous control guidance. As a consequence, central corrections and sequential commands may be issued rapidly, without waiting for the end of kinematic responses to each command, which may be important for many motor behaviours including typing, piano playing and speech. Our study also illustrates that the timing of the control signals may be substantially different from that of the resulting motor output and that the same control pattern may produce different motor outputs depending on external conditions.

  7. Insurance-markets Equilibrium with Sequential Non-convex Straight-time and Over-time Labor Supply

    OpenAIRE

    Vasilev, Aleksandar

    2016-01-01

    This note describes the lottery- and insurance-market equilibrium in an economy with non-convex straight-time and overtime employment. In contrast to Hansen and Sargent (1988), the overtime-decision is a sequential one. This requires two separate insurance market to operate, one for straight-time work, and one for overtime. In addi- tion, given that the labor choice for regular and overtime hours is made in succession, the insurance market for overtime needs to open once the insurance market ...

  8. A sequential threshold cure model for genetic analysis of time-to-event data

    DEFF Research Database (Denmark)

    Ødegård, J; Madsen, Per; Labouriau, Rodrigo S.

    2011-01-01

    In analysis of time-to-event data, classical survival models ignore the presence of potential nonsusceptible (cured) individuals, which, if present, will invalidate the inference procedures. Existence of nonsusceptible individuals is particularly relevant under challenge testing with specific...... pathogens, which is a common procedure in aquaculture breeding schemes. A cure model is a survival model accounting for a fraction of nonsusceptible individuals in the population. This study proposes a mixed cure model for time-to-event data, measured as sequential binary records. In a simulation study...... survival data were generated through 2 underlying traits: susceptibility and endurance (risk of dying per time-unit), associated with 2 sets of underlying liabilities. Despite considerable phenotypic confounding, the proposed model was largely able to distinguish the 2 traits. Furthermore, if selection...

  9. Simulation Study of Real Time 3-D Synthetic Aperture Sequential Beamforming for Ultrasound Imaging

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Rasmussen, Morten Fischer; Stuart, Matthias Bo

    2014-01-01

    in the main system. The real-time imaging capability is achieved using a synthetic aperture beamforming technique, utilizing the transmit events to generate a set of virtual elements that in combination can generate an image. The two core capabilities in combination is named Synthetic Aperture Sequential......This paper presents a new beamforming method for real-time three-dimensional (3-D) ultrasound imaging using a 2-D matrix transducer. To obtain images with sufficient resolution and contrast, several thousand elements are needed. The proposed method reduces the required channel count from...... Beamforming (SASB). Simulations are performed to evaluate the image quality of the presented method in comparison to Parallel beamforming utilizing 16 receive beamformers. As indicators for image quality the detail resolution and Cystic resolution are determined for a set of scatterers at a depth of 90mm...

  10. Ego Depletion in Real-Time: An Examination of the Sequential-Task Paradigm.

    Science.gov (United States)

    Arber, Madeleine M; Ireland, Michael J; Feger, Roy; Marrington, Jessica; Tehan, Joshua; Tehan, Gerald

    2017-01-01

    Current research into self-control that is based on the sequential task methodology is currently at an impasse. The sequential task methodology involves completing a task that is designed to tax self-control resources which in turn has carry-over effects on a second, unrelated task. The current impasse is in large part due to the lack of empirical research that tests explicit assumptions regarding the initial task. Five studies test one key, untested assumption underpinning strength (finite resource) models of self-regulation: Performance will decline over time on a task that depletes self-regulatory resources. In the aftermath of high profile replication failures using a popular letter-crossing task and subsequent criticisms of that task, the current studies examined whether depletion effects would occur in real time using letter-crossing tasks that did not invoke habit-forming and breaking, and whether these effects were moderated by administration type (paper and pencil vs. computer administration). Sample makeup and sizes as well as response formats were also varied across the studies. The five studies yielded a clear and consistent pattern of increasing performance deficits (errors) as a function of time spent on task with generally large effects and in the fifth study the strength of negative transfer effects to a working memory task were related to individual differences in depletion. These results demonstrate that some form of depletion is occurring on letter-crossing tasks though whether an internal regulatory resource reservoir or some other factor is changing across time remains an important question for future research.

  11. Ego Depletion in Real-Time: An Examination of the Sequential-Task Paradigm

    Directory of Open Access Journals (Sweden)

    Madeleine M. Arber

    2017-09-01

    Full Text Available Current research into self-control that is based on the sequential task methodology is currently at an impasse. The sequential task methodology involves completing a task that is designed to tax self-control resources which in turn has carry-over effects on a second, unrelated task. The current impasse is in large part due to the lack of empirical research that tests explicit assumptions regarding the initial task. Five studies test one key, untested assumption underpinning strength (finite resource models of self-regulation: Performance will decline over time on a task that depletes self-regulatory resources. In the aftermath of high profile replication failures using a popular letter-crossing task and subsequent criticisms of that task, the current studies examined whether depletion effects would occur in real time using letter-crossing tasks that did not invoke habit-forming and breaking, and whether these effects were moderated by administration type (paper and pencil vs. computer administration. Sample makeup and sizes as well as response formats were also varied across the studies. The five studies yielded a clear and consistent pattern of increasing performance deficits (errors as a function of time spent on task with generally large effects and in the fifth study the strength of negative transfer effects to a working memory task were related to individual differences in depletion. These results demonstrate that some form of depletion is occurring on letter-crossing tasks though whether an internal regulatory resource reservoir or some other factor is changing across time remains an important question for future research.

  12. Time-Sequential Working Wavelength-Selective Filter for Flat Autostereoscopic Displays

    Directory of Open Access Journals (Sweden)

    René de la Barré

    2017-02-01

    Full Text Available A time-sequential working, spatially-multiplexed autostereoscopic 3D display design consisting of a fast switchable RGB-color filter array and a fast color display is presented. The newly-introduced 3D display design is usable as a multi-user display, as well as a single-user system. The wavelength-selective filter barrier emits the light from a larger aperture than common autostereoscopic barrier displays with similar barrier pitch and ascent. Measurements on a demonstrator with commercial display components, simulations and computational evaluations have been carried out to describe the proposed wavelength-selective display design in static states and to show the weak spots of display filters in commercial displays. An optical modelling of wavelength-selective barriers has been used for instance to calculate the light ray distribution properties of that arrangement. In the time-sequential implementation, it is important to avoid that quick eye or eyelid movement leads to visible color artifacts. Therefore, color filter cells, switching faster than conventional LC display cells, must distribute directed light from different primaries at the same time, to create a 3D presentation. For that, electric tunable liquid crystal Fabry–Pérot color filters are presented. They switch on-off the colors red, green and blue in the millisecond regime. Their active areas consist of a sub-micrometer-thick nematic layer sandwiched between dielectric mirrors and indium tin oxide (ITO-electrodes. These cells shall switch narrowband light of red, green or blue. A barrier filter array for a high resolution, glasses-free 3D display has to be equipped with several thousand switchable filter elements having different color apertures.

  13. The influence of spatial congruency and movement preparation time on saccade curvature in simultaneous and sequential dual-tasks.

    Science.gov (United States)

    Moehler, Tobias; Fiehler, Katja

    2015-11-01

    Saccade curvature represents a sensitive measure of oculomotor inhibition with saccades curving away from covertly attended locations. Here we investigated whether and how saccade curvature depends on movement preparation time when a perceptual task is performed during or before saccade preparation. Participants performed a dual-task including a visual discrimination task at a cued location and a saccade task to the same location (congruent) or to a different location (incongruent). Additionally, we varied saccade preparation time (time between saccade cue and Go-signal) and the occurrence of the discrimination task (during saccade preparation=simultaneous vs. before saccade preparation=sequential). We found deteriorated perceptual performance in incongruent trials during simultaneous task performance while perceptual performance was unaffected during sequential task performance. Saccade accuracy and precision were deteriorated in incongruent trials during simultaneous and, to a lesser extent, also during sequential task performance. Saccades consistently curved away from covertly attended non-saccade locations. Saccade curvature was unaffected by movement preparation time during simultaneous task performance but decreased and finally vanished with increasing movement preparation time during sequential task performance. Our results indicate that the competing saccade plan to the covertly attended non-saccade location is maintained during simultaneous task performance until the perceptual task is solved while in the sequential condition, in which the discrimination task is solved prior to the saccade task, oculomotor inhibition decays gradually with movement preparation time. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Optimal base-stock policy for the inventory system with periodic review, backorders and sequential lead times

    DEFF Research Database (Denmark)

    Johansen, Søren Glud; Thorstenson, Anders

    2008-01-01

    We extend well-known formulae for the optimal base stock of the inventory system with continuous review and constant lead time to the case with periodic review and stochastic, sequential lead times. Our extension uses the notion of the 'extended lead time'. The derived performance measures...

  15. Sequential cloud point extraction for the speciation of mercury in seafood by inductively coupled plasma optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li Yingjie [Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu Bin [Department of Chemistry, Wuhan University, Wuhan 430072 (China)], E-mail: binhu@whu.edu.cn

    2007-10-15

    A novel nonchromatographic speciation technique for the speciation of mercury by sequential cloud point extraction (CPE) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. The method based on Hg{sup 2+} was complexed with I{sup -} to form HgI{sub 4}{sup 2-}, and the HgI{sub 4}{sup 2-} reacted with the methyl green (MG) cation to form hydrophobic ion-associated complex, and the ion-associated complex was then extracted into the surfactant-rich phase of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114), which are subsequently separated from methylmercury (MeHg{sup +}) in the initial solution by centrifugation. The surfactant-rich phase containing Hg(II) was diluted with 0.5 mol L{sup -1} HNO{sub 3} for ICP-OES determination. The supernatant is also subjected to the similar CPE procedure for the preconcentration of MeHg{sup +} by the addition of a chelating agent, ammonium pyrrolidine dithiocarbamate (APDC), in order to form water-insolvable complex with MeHg{sup +}. The MeHg{sup +} in the micelles was directly analyzed after disposal as describe above. Under the optimized conditions, the extraction efficiency was 93.5% for Hg(II) and 51.5% for MeHg{sup +} with the enrichment factor of 18.7 for Hg(II) and 10.3 for MeHg{sup +}, respectively. The limits of detection (LODs) were 56.3 ng L{sup -1} for Hg(II) and 94.6 ng L{sup -1} for MeHg{sup +} (as Hg) with the relative standard deviations (RSDs) of 3.6% for Hg(II) and 4.5% for MeHg{sup +} (C = 10 {mu}g L{sup -1}, n = 7), respectively. The developed technique was applied to the speciation of mercury in real seafood samples and the recoveries for spiked samples were found to be in the range of 93.2-108.7%. For validation, a certified reference material of DORM-2 (dogfish muscle) was analyzed and the determined values are in good agreement with the certified values.

  16. Sequential cloud point extraction for the speciation of mercury in seafood by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Li Yingjie; Hu Bin

    2007-01-01

    A novel nonchromatographic speciation technique for the speciation of mercury by sequential cloud point extraction (CPE) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. The method based on Hg 2+ was complexed with I - to form HgI 4 2- , and the HgI 4 2- reacted with the methyl green (MG) cation to form hydrophobic ion-associated complex, and the ion-associated complex was then extracted into the surfactant-rich phase of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114), which are subsequently separated from methylmercury (MeHg + ) in the initial solution by centrifugation. The surfactant-rich phase containing Hg(II) was diluted with 0.5 mol L -1 HNO 3 for ICP-OES determination. The supernatant is also subjected to the similar CPE procedure for the preconcentration of MeHg + by the addition of a chelating agent, ammonium pyrrolidine dithiocarbamate (APDC), in order to form water-insolvable complex with MeHg + . The MeHg + in the micelles was directly analyzed after disposal as describe above. Under the optimized conditions, the extraction efficiency was 93.5% for Hg(II) and 51.5% for MeHg + with the enrichment factor of 18.7 for Hg(II) and 10.3 for MeHg + , respectively. The limits of detection (LODs) were 56.3 ng L -1 for Hg(II) and 94.6 ng L -1 for MeHg + (as Hg) with the relative standard deviations (RSDs) of 3.6% for Hg(II) and 4.5% for MeHg + (C = 10 μg L -1 , n = 7), respectively. The developed technique was applied to the speciation of mercury in real seafood samples and the recoveries for spiked samples were found to be in the range of 93.2-108.7%. For validation, a certified reference material of DORM-2 (dogfish muscle) was analyzed and the determined values are in good agreement with the certified values

  17. Activation time and material stiffness of sequential removable orthodontic appliances. Part 2: Dental improvements.

    Science.gov (United States)

    Clements, Karen Michelle; Bollen, Anne-Marie; Huang, Greg; King, Greg; Hujoel, Philippe; Ma, Tsun

    2003-11-01

    Fifty-one patients were enrolled in this study to explore the treatment effects of material stiffness and frequency of appliance change when using clear, sequential, removable appliances (aligners). Patients were stratified based on pretreatment peer assessment rating (PAR) scores and need for extractions. They were randomized into 4 treatment protocols: 1-week activation with soft material, 1-week activation with hard material, 2-week activation with soft material, and 2-week activation with hard material. Patients continued with their protocols until either the series of aligners was completed, or until it was determined that the aligner was not fitting well (study end point). Weighted PAR score and average incisor irregularity (AII) indexes were used to measure pretreatment and end-point study models, and average improvement was compared among the 4 groups. In addition to the evaluation of the 4 treatment groups, comparisons were made of the individual components of the PAR score to determine which occlusal components experienced the most correction with the aligners. The percentages and absolute extraction space closures were evaluated, and papillary bleeding scores before and during treatment were compared. Although no statistical difference was observed between the 4 treatment groups, a trend was noted with the 2-week frequency having a larger percentage of reduction in weighted PAR and AII scores, and greater extraction space closure. Anterior alignment was the most improved component, and buccal occlusion was the least improved. When analyzed by type of extraction, incisor extraction sites had a significantly greater percentage of closure than either maxillary or mandibular premolar extraction sites. A statistically significant decrease in mean average papillary bleeding score was found during treatment when compared with pretreatment scores, although this difference was not clinically significant.

  18. Note: Optimal base-stock policy for the inventory system with periodic review, backorders and sequential lead times

    DEFF Research Database (Denmark)

    Johansen, Søren Glud; Thorstenson, Anders

    We show that well-known textbook formulae for determining the optimal base stock of the inventory system with continuous review and constant lead time can easily be extended to the case with periodic review and stochastic, sequential lead times. The provided performance measures and conditions...

  19. A Feedback Optimal Control Algorithm with Optimal Measurement Time Points

    Directory of Open Access Journals (Sweden)

    Felix Jost

    2017-02-01

    Full Text Available Nonlinear model predictive control has been established as a powerful methodology to provide feedback for dynamic processes over the last decades. In practice it is usually combined with parameter and state estimation techniques, which allows to cope with uncertainty on many levels. To reduce the uncertainty it has also been suggested to include optimal experimental design into the sequential process of estimation and control calculation. Most of the focus so far was on dual control approaches, i.e., on using the controls to simultaneously excite the system dynamics (learning as well as minimizing a given objective (performing. We propose a new algorithm, which sequentially solves robust optimal control, optimal experimental design, state and parameter estimation problems. Thus, we decouple the control and the experimental design problems. This has the advantages that we can analyze the impact of measurement timing (sampling independently, and is practically relevant for applications with either an ethical limitation on system excitation (e.g., chemotherapy treatment or the need for fast feedback. The algorithm shows promising results with a 36% reduction of parameter uncertainties for the Lotka-Volterra fishing benchmark example.

  20. Time sequential single photon emission computed tomography studies in brain tumour using thallium-201

    International Nuclear Information System (INIS)

    Ueda, Takashi; Kaji, Yasuhiro; Wakisaka, Shinichiro; Watanabe, Katsushi; Hoshi, Hiroaki; Jinnouchi, Seishi; Futami, Shigemi

    1993-01-01

    Time sequential single photon emission computed tomography (SPECT) studies using thallium-201 were performed in 25 patients with brain tumours to evaluate the kinetics of thallium in the tumour and the biological malignancy grade preoperatively. After acquisition and reconstruction of SPECT data from 1 min post injection to 48 h (1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 15-20 min, followed by 4-6, 24 and 48 h), the thallium uptake ratio in the tumour versus the homologous contralateral area of the brain was calculated and compared with findings of X-ray CT, magnetic resonance imaging, cerebral angiography and histological investigations. Early uptake of thallium in tumours was related to tumour vascularity and the disruption of the blood-brain barrier. High and rapid uptake and slow reduction of thallium indicated a hypervascular malignant tumour; however, high and rapid uptake but rapid reduction of thallium indicated a hypervascular benign tumour, such as meningioma. Hypovascular and benign tumours tended to show low uptake and slow reduction of thallium. Long-lasting retention or uptake of thallium indicates tumour malignancy. (orig.)

  1. Dual-time-point Imaging and Delayed-time-point Fluorodeoxyglucose-PET/Computed Tomography Imaging in Various Clinical Settings

    DEFF Research Database (Denmark)

    Houshmand, Sina; Salavati, Ali; Antonsen Segtnan, Eivind

    2016-01-01

    The techniques of dual-time-point imaging (DTPI) and delayed-time-point imaging, which are mostly being used for distinction between inflammatory and malignant diseases, has increased the specificity of fluorodeoxyglucose (FDG)-PET for diagnosis and prognosis of certain diseases. A gradually incr...

  2. Time Eigenstates for Potential Functions without Extremal Points

    Directory of Open Access Journals (Sweden)

    Gabino Torres-Vega

    2013-09-01

    Full Text Available In a previous paper, we introduced a way to generate a time coordinate system for classical and quantum systems when the potential function has extremal points. In this paper, we deal with the case in which the potential function has no extremal points at all, and we illustrate the method with the harmonic and linear potentials.

  3. Noninferiority, randomized, controlled trial comparing embryo development using media developed for sequential or undisturbed culture in a time-lapse setup.

    Science.gov (United States)

    Hardarson, Thorir; Bungum, Mona; Conaghan, Joe; Meintjes, Marius; Chantilis, Samuel J; Molnar, Laszlo; Gunnarsson, Kristina; Wikland, Matts

    2015-12-01

    To study whether a culture medium that allows undisturbed culture supports human embryo development to the blastocyst stage equivalently to a well-established sequential media. Randomized, double-blinded sibling trial. Independent in vitro fertilization (IVF) clinics. One hundred twenty-eight patients, with 1,356 zygotes randomized into two study arms. Embryos randomly allocated into two study arms to compare embryo development on a time-lapse system using a single-step medium or sequential media. Percentage of good-quality blastocysts on day 5. Percentage of day 5 good-quality blastocysts was 21.1% (standard deviation [SD] ± 21.6%) and 22.2% (SD ± 22.1%) in the single-step time-lapse medium (G-TL) and the sequential media (G-1/G-2) groups, respectively. The mean difference (-1.2; 95% CI, -6.0; 3.6) between the two media systems for the primary end point was less than the noninferiority margin of -8%. There was a statistically significantly lower number of good-quality embryos on day 3 in the G-TL group [50.7% (SD ± 30.6%) vs. 60.8% (SD ± 30.7%)]. Four out of the 11 measured morphokinetic parameters were statistically significantly different for the two media used. The mean levels of ammonium concentration in the media at the end of the culture period was statistically significantly lower in the G-TL group as compared with the G-2 group. We have shown that a single-step culture medium supports blastocyst development equivalently to established sequential media. The ammonium concentrations were lower in the single-step media, and the measured morphokinetic parameters were modified somewhat. NCT01939626. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Homeless Point-In-Time (2007-2016)

    Data.gov (United States)

    City and County of Durham, North Carolina — These raw data sets contain Point-in-Time (PIT) estimates and national PIT estimates of homelessness as well as national estimates of homelessness by state and...

  5. Title XVI / Supplemental Security Record Point In Time (SSRPT)

    Data.gov (United States)

    Social Security Administration — This is the point-in-time database to house temporary Supplemental Security Record (SSR) images produced during the course of the operating day before they can be...

  6. Change detection in polarimetric SAR data over several time points

    DEFF Research Database (Denmark)

    Conradsen, Knut; Nielsen, Allan Aasbjerg; Skriver, Henning

    2014-01-01

    A test statistic for the equality of several variance-covariance matrices following the complex Wishart distribution is introduced. The test statistic is applied successfully to detect change in C-band EMISAR polarimetric SAR data over four time points.......A test statistic for the equality of several variance-covariance matrices following the complex Wishart distribution is introduced. The test statistic is applied successfully to detect change in C-band EMISAR polarimetric SAR data over four time points....

  7. Attention flexibly trades off across points in time.

    Science.gov (United States)

    Denison, Rachel N; Heeger, David J; Carrasco, Marisa

    2017-08-01

    Sensory signals continuously enter the brain, raising the question of how perceptual systems handle this constant flow of input. Attention to an anticipated point in time can prioritize visual information at that time. However, how we voluntarily attend across time when there are successive task-relevant stimuli has been barely investigated. We developed a novel experimental protocol that allowed us to assess, for the first time, both the benefits and costs of voluntary temporal attention when perceiving a short sequence of two or three visual targets with predictable timing. We found that when humans directed attention to a cued point in time, their ability to perceive orientation was better at that time but also worse earlier and later. These perceptual tradeoffs across time are analogous to those found across space for spatial attention. We concluded that voluntary attention is limited, and selective, across time.

  8. History and Point in Time in Enterprise Applications

    Directory of Open Access Journals (Sweden)

    Constantin Gelu APOSTOL

    2006-01-01

    Full Text Available First part points out the main differences between temporal and non-temporal databases. In the second part, based on identification of the three main categories of time involved in database applications: user-defined time, valid time and transaction time, some relevant solutions for their implementation are discussed, mainly from the point of view of database organization and data access level of enterprise applications. The final part is dedicated to the influences of historical data in the business logic and presentation levels of enterprise applications and in application services, as security, workflow, reporting.

  9. Clinical Significance of F 18 FP CIT Dual Time Point PET Imaging in Idiopathic Parkinson's Disease

    International Nuclear Information System (INIS)

    Oh, Jin Kyoung; Yoo, Ik Dong; Seo, Ye Young; Chung, Youg An; Yoo, Ie Ryung; Kim, Sung Hoon; Song, In Uk

    2011-01-01

    The purpose of this study was to investigate the diagnostic value of dual time point F 18 FP CIT PET imaging in idiopathic Parkinson's disease (PD). Twenty four patients with PD (mean age 69.6) and 18 healthy people (mean age 70.26) underwent two sequential PET/CT scans (dual time point imaging) at 90 and 210 min after F 18 FP CIT injection. Tracer activity of region of interest was measured in the caudate, putamen and a reference region in the brain from both time points. The outcome parameter was the striatooccipital ratio (SOR). Normal SOR values were obtained in the control group. The percent change in tracer activity between 90 and 210 min images was calculated. The SOR values and the percent change in tracer activity were compared between the patients and healthy control group. The SOR values for the caudate, anterior and posterior putamen at both 90 and 210 min images were significantly reduced in the patients with PD. The lowest P value was obtained for the anterior and posterior putamen (p<0.001) at both time points. There were significant differences of the percent change in tracer activity for the anterior and posterior putamen in the two groups (p=0.01) F 18 FP CIT PET scans at 90 and 210 min after injection are both able to diagnose PD. Therefore, the 90 min image by itself in sufficient for diagnosing PD.

  10. When should we recommend use of dual time-point and delayed time-point imaging techniques in FDG PET?

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Gang [Philadelphia VA Medical Center, Department of Radiology, Philadelphia, PA (United States); Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Torigian, Drew A.; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Zhuang, Hongming [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2013-05-15

    FDG PET and PET/CT are now widely used in oncological imaging for tumor characterization, staging, restaging, and response evaluation. However, numerous benign etiologies may cause increased FDG uptake indistinguishable from that of malignancy. Multiple studies have shown that dual time-point imaging (DTPI) of FDG PET may be helpful in differentiating malignancy from benign processes. However, exceptions exist, and some studies have demonstrated significant overlap of FDG uptake patterns between benign and malignant lesions on delayed time-point images. In this review, we summarize our experience and opinions on the value of DTPI and delayed time-point imaging in oncology, with a review of the relevant literature. We believe that the major value of DTPI and delayed time-point imaging is the increased sensitivity due to continued clearance of background activity and continued FDG accumulation in malignant lesions, if the same diagnostic criteria (as in the initial standard single time-point imaging) are used. The specificity of DTPI and delayed time-point imaging depends on multiple factors, including the prevalence of malignancies, the patient population, and the cut-off values (either SUV or retention index) used to define a malignancy. Thus, DTPI and delayed time-point imaging would be more useful if performed for evaluation of lesions in regions with significant background activity clearance over time (such as the liver, the spleen, the mediastinum), and if used in the evaluation of the extent of tumor involvement rather than in the characterization of the nature of any specific lesion. Acute infectious and non-infectious inflammatory lesions remain as the major culprit for diminished diagnostic performance of these approaches (especially in tuberculosis-endemic regions). Tumor heterogeneity may also contribute to inconsistent performance of DTPI. The authors believe that selective use of DTPI and delayed time-point imaging will improve diagnostic accuracy and

  11. Inhomogeneities detection in annual precipitation time series in Portugal using direct sequential simulation

    Science.gov (United States)

    Caineta, Júlio; Ribeiro, Sara; Costa, Ana Cristina; Henriques, Roberto; Soares, Amílcar

    2014-05-01

    Climate data homogenisation is of major importance in monitoring climate change, the validation of weather forecasting, general circulation and regional atmospheric models, modelling of erosion, drought monitoring, among other studies of hydrological and environmental impacts. This happens because non-climate factors can cause time series discontinuities which may hide the true climatic signal and patterns, thus potentially bias the conclusions of those studies. In the last two decades, many methods have been developed to identify and remove these inhomogeneities. One of those is based on geostatistical simulation (DSS - direct sequential simulation), where local probability density functions (pdf) are calculated at candidate monitoring stations, using spatial and temporal neighbouring observations, and then are used for detection of inhomogeneities. This approach has been previously applied to detect inhomogeneities in four precipitation series (wet day count) from a network with 66 monitoring stations located in the southern region of Portugal (1980-2001). This study revealed promising results and the potential advantages of geostatistical techniques for inhomogeneities detection in climate time series. This work extends the case study presented before and investigates the application of the geostatistical stochastic approach to ten precipitation series that were previously classified as inhomogeneous by one of six absolute homogeneity tests (Mann-Kendall test, Wald-Wolfowitz runs test, Von Neumann ratio test, Standard normal homogeneity test (SNHT) for a single break, Pettit test, and Buishand range test). Moreover, a sensibility analysis is implemented to investigate the number of simulated realisations that should be used to accurately infer the local pdfs. Accordingly, the number of simulations per iteration is increased from 50 to 500, which resulted in a more representative local pdf. A set of default and recommended settings is provided, which will help

  12. Timed sequential chemotherapy of cytoxan-refractory multiple myeloma with cytoxan and adriamycin based on induced tumor proliferation.

    Science.gov (United States)

    Karp, J E; Humphrey, R L; Burke, P J

    1981-03-01

    Malignant plasma cell proliferation and induced humoral stimulatory activity (HSA) occur in vivo at a predictable time following drug administration. Sequential sera from 11 patients with poor-risk multiple myeloma (MM) undergoing treatment with Cytoxan (CY) 2400 mq/sq m were assayed for their in vitro effects on malignant bone marrow plasma cell tritiated thymidine (3HTdR) incorporation. Peak HSA was detected day 9 following CY. Sequential changes in marrow malignant plasma cell 3HTdR-labeling indices (LI) paralleled changes in serum activity, with peak LI occurring at the time of peak HS. An in vitro model of chemotherapy demonstrated that malignant plasma cell proliferation was enhanced by HSA, as determined by 3HTdR incorporation assay, 3HTdR LI, and tumor cells counts, and that stimulated plasma cells were more sensitive to cytotoxic effects of adriamycin (ADR) than were cells cultured in autologous pretreatment serum. Based on these studies, we designed a clinical trial to treat 12 CY-refractory poor-risk patients with MM in which ADR (60 mg/sq m) was administered at the time of peak HSA and residual tumor cell LI (day 9) following initial CY, 2400 mg/m (CY1ADR9). Eight of 12 (67%) responded to timed sequential chemotherapy with a greater than 50% decrement in monoclonal protein marker and a median survival projected to be greater than 8 mo duration (range 4-21+ mo). These clinical results using timed sequential CY1ADR9 compare favorably with results obtained using ADR in nonsequential chemotherapeutic regimens.

  13. A Robust Real Time Direction-of-Arrival Estimation Method for Sequential Movement Events of Vehicles.

    Science.gov (United States)

    Liu, Huawei; Li, Baoqing; Yuan, Xiaobing; Zhou, Qianwei; Huang, Jingchang

    2018-03-27

    Parameters estimation of sequential movement events of vehicles is facing the challenges of noise interferences and the demands of portable implementation. In this paper, we propose a robust direction-of-arrival (DOA) estimation method for the sequential movement events of vehicles based on a small Micro-Electro-Mechanical System (MEMS) microphone array system. Inspired by the incoherent signal-subspace method (ISM), the method that is proposed in this work employs multiple sub-bands, which are selected from the wideband signals with high magnitude-squared coherence to track moving vehicles in the presence of wind noise. The field test results demonstrate that the proposed method has a better performance in emulating the DOA of a moving vehicle even in the case of severe wind interference than the narrowband multiple signal classification (MUSIC) method, the sub-band DOA estimation method, and the classical two-sided correlation transformation (TCT) method.

  14. Dedicated workspaces: Faster resumption times and reduced cognitive load in sequential multitasking

    DEFF Research Database (Denmark)

    Jeuris, Steven; Bardram, Jakob Eyvind

    2016-01-01

    Studies show that virtual desktops have become a widespread approach to window management within desktop environments. However, despite their success, there is no experimental evidence of their effect on multitasking. In this paper, we present an experimental study incorporating 16 participants...... to perform the same tasks. Results show that adopting virtual desktops as dedicated workspaces allows for faster task resumption (10 s faster on average) and reduced cognitive load during sequential multitasking. Within our experiment the majority of users already benefited from using dedicated workspaces...

  15. Motor timing deficits in sequential movements in Parkinson disease are related to action planning: a motor imagery study.

    Directory of Open Access Journals (Sweden)

    Laura Avanzino

    Full Text Available Timing of sequential movements is altered in Parkinson disease (PD. Whether timing deficits in internally generated sequential movements in PD depends also on difficulties in motor planning, rather than merely on a defective ability to materially perform the planned movement is still undefined. To unveil this issue, we adopted a modified version of an established test for motor timing, i.e. the synchronization-continuation paradigm, by introducing a motor imagery task. Motor imagery is thought to involve mainly processes of movement preparation, with reduced involvement of end-stage movement execution-related processes. Fourteen patients with PD and twelve matched healthy volunteers were asked to tap in synchrony with a metronome cue (SYNC and then, when the tone stopped, to keep tapping, trying to maintain the same rhythm (CONT-EXE or to imagine tapping at the same rhythm, rather than actually performing it (CONT-MI. We tested both a sub-second and a supra-second inter-stimulus interval between the cues. Performance was recorded using a sensor-engineered glove and analyzed measuring the temporal error and the interval reproduction accuracy index. PD patients were less accurate than healthy subjects in the supra-second time reproduction task when performing both continuation tasks (CONT-MI and CONT-EXE, whereas no difference was detected in the synchronization task and on all tasks involving a sub-second interval. Our findings suggest that PD patients exhibit a selective deficit in motor timing for sequential movements that are separated by a supra-second interval and that this deficit may be explained by a defect of motor planning. Further, we propose that difficulties in motor planning are of a sufficient degree of severity in PD to affect also the motor performance in the supra-second time reproduction task.

  16. Point splitting in a curved space-time background

    International Nuclear Information System (INIS)

    Liggatt, P.A.J.; Macfarlane, A.J.

    1979-01-01

    A prescription is given for point splitting in a curved space-time background which is a natural generalization of that familiar in quantum electrodynamics and Yang-Mills theory. It is applied (to establish its validity) to the verification of the gravitational anomaly in the divergence of a fermion axial current. Notable features of the prescription are that it defines a point-split current that can be differentiated straightforwardly, and that it involves a natural way of averaging (four-dimensionally) over the directions of point splitting. The method can extend directly from the spin-1/2 fermion case treated to other cases, e.g., to spin-3/2 Rarita-Schwinger fermions. (author)

  17. Use of sequential diagnostic pain blocks in a patient of posttraumatic complex regional pain syndrome-not otherwise specified complicated by myofascial trigger points and thoracolumbar pain syndrome

    Directory of Open Access Journals (Sweden)

    Kailash Kothari

    2017-01-01

    Full Text Available We are presenting a case of posttraumatic lower limb Complex regional pain syndrome – Not otherwise specified (CRPS – NOS. As it was not treated in acute phase, the pain became chronic and got complicated by myofascial and thoracolumbar pain syndrome. This case posed us a diagnostic challenge. We used sequential diagnostic pain blocks to identify the pain generators and successfully treat the patient. We used diagnostic blocks step by step to identify and treat pain generators – T12,L1 and L2 Facet joints, Lumbar sympathetic block for CRPS NOS and Trigger point injection with dry needling for myofascial pain syndrome. This case highlights the facet that additional pain generators unrelated to original pain may complicate the presentation. Identifying these pain generators requires out of box thinking and high index of suspicion.

  18. Nonlinear triple-point problems on time scales

    Directory of Open Access Journals (Sweden)

    Douglas R. Anderson

    2004-04-01

    Full Text Available We establish the existence of multiple positive solutions to the nonlinear second-order triple-point boundary-value problem on time scales, $$displaylines{ u^{Delta abla}(t+h(tf(t,u(t=0, cr u(a=alpha u(b+delta u^Delta(a,quad eta u(c+gamma u^Delta(c=0 }$$ for $tin[a,c]subsetmathbb{T}$, where $mathbb{T}$ is a time scale, $eta, gamma, deltage 0$ with $Beta+gamma>0$, $0

  19. Time Series ARIMA Models of Undergraduate Grade Point Average.

    Science.gov (United States)

    Rogers, Bruce G.

    The Auto-Regressive Integrated Moving Average (ARIMA) Models, often referred to as Box-Jenkins models, are regression methods for analyzing sequential dependent observations with large amounts of data. The Box-Jenkins approach, a three-stage procedure consisting of identification, estimation and diagnosis, was used to select the most appropriate…

  20. Numeric treatment of nonlinear second order multi-point boundary value problems using ANN, GAs and sequential quadratic programming technique

    Directory of Open Access Journals (Sweden)

    Zulqurnain Sabir

    2014-06-01

    Full Text Available In this paper, computational intelligence technique are presented for solving multi-point nonlinear boundary value problems based on artificial neural networks, evolutionary computing approach, and active-set technique. The neural network is to provide convenient methods for obtaining useful model based on unsupervised error for the differential equations. The motivation for presenting this work comes actually from the aim of introducing a reliable framework that combines the powerful features of ANN optimized with soft computing frameworks to cope with such challenging system. The applicability and reliability of such methods have been monitored thoroughly for various boundary value problems arises in science, engineering and biotechnology as well. Comprehensive numerical experimentations have been performed to validate the accuracy, convergence, and robustness of the designed scheme. Comparative studies have also been made with available standard solution to analyze the correctness of the proposed scheme.

  1. Multimodal sensory integration during sequential eating--linking chewing activity, aroma release, and aroma perception over time.

    Science.gov (United States)

    Leclercq, Ségolène; Blancher, Guillaume

    2012-10-01

    The respective effects of chewing activity, aroma release from a gelled candy, and aroma perception were investigated. Specifically, the study aimed at 1) comparing an imposed chewing and swallowing pattern (IP) and free protocol (FP) on panelists for in vivo measurements, 2) investigating carryover effects in sequential eating, and 3) studying the link between instrumental data and their perception counterpart. Chewing activity, in-nose aroma concentration, and aroma perception over time were measured by electromyography, proton transfer reaction-mass spectrometry, and time intensity, respectively. Model gel candies were flavored at 2 intensity levels (low-L and high-H). The panelists evaluated 3 sequences (H then H, H then L, and L then H) in duplicates with both IP and FP. They scored aroma intensity over time while their in-nose aroma concentrations and their chewing activity were measured. Overall, only limited advantages were found in imposing a chewing and swallowing pattern for instrumental and sensory data. In addition, the study highlighted the role of brain integration on perceived intensity and dynamics of perception, in the framework of sequential eating without rinsing. Because of the presence of adaptation phenomena, contrast effect, and potential taste and texture cross-modal interaction with aroma perception, it was concluded that dynamic in-nose concentration data provide only one part of the perception picture and therefore cannot be used alone in prediction models.

  2. Accuracy of multi-point boundary crossing time analysis

    Directory of Open Access Journals (Sweden)

    J. Vogt

    2011-12-01

    Full Text Available Recent multi-spacecraft studies of solar wind discontinuity crossings using the timing (boundary plane triangulation method gave boundary parameter estimates that are significantly different from those of the well-established single-spacecraft minimum variance analysis (MVA technique. A large survey of directional discontinuities in Cluster data turned out to be particularly inconsistent in the sense that multi-point timing analyses did not identify any rotational discontinuities (RDs whereas the MVA results of the individual spacecraft suggested that RDs form the majority of events. To make multi-spacecraft studies of discontinuity crossings more conclusive, the present report addresses the accuracy of the timing approach to boundary parameter estimation. Our error analysis is based on the reciprocal vector formalism and takes into account uncertainties both in crossing times and in the spacecraft positions. A rigorous error estimation scheme is presented for the general case of correlated crossing time errors and arbitrary spacecraft configurations. Crossing time error covariances are determined through cross correlation analyses of the residuals. The principal influence of the spacecraft array geometry on the accuracy of the timing method is illustrated using error formulas for the simplified case of mutually uncorrelated and identical errors at different spacecraft. The full error analysis procedure is demonstrated for a solar wind discontinuity as observed by the Cluster FGM instrument.

  3. Early lymphocyte recovery after intensive timed sequential chemotherapy for acute myelogenous leukemia: peripheral oligoclonal expansion of regulatory T cells.

    Science.gov (United States)

    Kanakry, Christopher G; Hess, Allan D; Gocke, Christopher D; Thoburn, Christopher; Kos, Ferdynand; Meyer, Christian; Briel, Janet; Luznik, Leo; Smith, B Douglas; Levitsky, Hyam; Karp, Judith E

    2011-01-13

    Few published studies characterize early lymphocyte recovery after intensive chemotherapy for acute myelogenous leukemia (AML). To test the hypothesis that lymphocyte recovery mirrors ontogeny, we characterized early lymphocyte recovery in 20 consecutive patients undergoing induction timed sequential chemotherapy for newly diagnosed AML. Recovering T lymphocytes were predominantly CD4(+) and included a greatly expanded population of CD3(+)CD4(+)CD25(+)Foxp3(+) T cells. Recovering CD3(+)CD4(+)CD25(+)Foxp3(+) T cells were phenotypically activated regulatory T cells and showed suppressive activity on cytokine production in a mixed lymphocyte reaction. Despite an initial burst of thymopoiesis, most recovering regulatory T cells were peripherally derived. Furthermore, regulatory T cells showed marked oligoclonal skewing, suggesting that their peripheral expansion was antigen-driven. Overall, lymphocyte recovery after chemotherapy differs from ontogeny, specifically identifying a peripherally expanded oligoclonal population of activated regulatory T lymphocytes. These differences suggest a stereotyped immunologic recovery shared by patients with newly diagnosed AML after induction timed sequential chemotherapy. Further insight into this oligoclonal regulatory T-cell population will be fundamental toward developing effective immunomodulatory techniques to improve survival for patients with AML.

  4. A Sequential, Implicit, Wavelet-Based Solver for Multi-Scale Time-Dependent Partial Differential Equations

    Directory of Open Access Journals (Sweden)

    Donald A. McLaren

    2013-04-01

    Full Text Available This paper describes and tests a wavelet-based implicit numerical method for solving partial differential equations. Intended for problems with localized small-scale interactions, the method exploits the form of the wavelet decomposition to divide the implicit system created by the time-discretization into multiple smaller systems that can be solved sequentially. Included is a test on a basic non-linear problem, with both the results of the test, and the time required to calculate them, compared with control results based on a single system with fine resolution. The method is then tested on a non-trivial problem, its computational time and accuracy checked against control results. In both tests, it was found that the method requires less computational expense than the control. Furthermore, the method showed convergence towards the fine resolution control results.

  5. Assessing the magnitude and trends in hospital acquired infections in Canadian hospitals through sequential point prevalence surveys

    Directory of Open Access Journals (Sweden)

    Geoffrey Taylor

    2016-05-01

    Full Text Available Abstract Background Healthcare acquired infections (HAI are an important public health problem in developed countries, but comprehensive data on trends over time are lacking. Prevalence surveys have been used as a surrogate for incidence studies and can be readily repeated. Methods The Canadian Nosocomial Infection Surveillance Program conducted prevalence surveys in 2002 and 2009 in a large network of major Canadian acute care hospitals. NHSN definitions of HAI were used. Use of isolation precautions on the survey day was documented. Results In 2009, 9,953 acute care inpatients were surveyed; 1,234 infections (124/1000 were found, compared to 111/1000 in 2002, (p < 0.0001. There was increased prevalence of urinary tract infection (UTI and Clostridium difficile, offset by decreases in pneumonia and bloodstream infection. Use of isolation precautions increased from 77 to 148 per 1000 patients (p < 0.0001, attributable to increased use of contact precautions in patients infected or colonized with antimicrobial resistant organisms. Conclusion Between 2002 and 2009 HAI prevalence increased by 11.7 % in a network of major Canadian hospitals due to increases in Clostridium difficile and urinary tract infection. The use of isolation precautions increased by 92.2 % attributable to increased contact isolation. National prevalence surveys are useful tools to assess evolving trends in HAI.

  6. Changes of peritoneal transport parameters with time on dialysis: assessment with sequential peritoneal equilibration test.

    Science.gov (United States)

    Waniewski, Jacek; Antosiewicz, Stefan; Baczynski, Daniel; Poleszczuk, Jan; Pietribiasi, Mauro; Lindholm, Bengt; Wankowicz, Zofia

    2017-10-27

    Sequential peritoneal equilibration test (sPET) is based on the consecutive performance of the peritoneal equilibration test (PET, 4-hour, glucose 2.27%) and the mini-PET (1-hour, glucose 3.86%), and the estimation of peritoneal transport parameters with the 2-pore model. It enables the assessment of the functional transport barrier for fluid and small solutes. The objective of this study was to check whether the estimated model parameters can serve as better and earlier indicators of the changes in the peritoneal transport characteristics than directly measured transport indices that depend on several transport processes. 17 patients were examined using sPET twice with the interval of about 8 months (230 ± 60 days). There was no difference between the observational parameters measured in the 2 examinations. The indices for solute transport, but not net UF, were well correlated between the examinations. Among the estimated parameters, a significant decrease between the 2 examinations was found only for hydraulic permeability LpS, and osmotic conductance for glucose, whereas the other parameters remained unchanged. These fluid transport parameters did not correlate with D/P for creatinine, although the decrease in LpS values between the examinations was observed mostly for patients with low D/P for creatinine. We conclude that changes in fluid transport parameters, hydraulic permeability and osmotic conductance for glucose, as assessed by the pore model, may precede the changes in small solute transport. The systematic assessment of fluid transport status needs specific clinical and mathematical tools beside the standard PET tests.

  7. On-line sequential injection-capillary electrophoresis for near-real-time monitoring of extracellular lactate in cell culture flasks.

    Science.gov (United States)

    Alhusban, Ala A; Gaudry, Adam J; Breadmore, Michael C; Gueven, Nuri; Guijt, Rosanne M

    2014-01-03

    Cell culture has replaced many in vivo studies because of ethical and regulatory measures as well as the possibility of increased throughput. Analytical assays to determine (bio)chemical changes are often based on end-point measurements rather than on a series of sequential determinations. The purpose of this work is to develop an analytical system for monitoring cell culture based on sequential injection-capillary electrophoresis (SI-CE) with capacitively coupled contactless conductivity detection (C(4)D). The system was applied for monitoring lactate production, an important metabolic indicator, during mammalian cell culture. Using a background electrolyte consisting of 25mM tris(hydroxymethyl)aminomethane, 35mM cyclohexyl-2-aminoethanesulfonic acid with 0.02% poly(ethyleneimine) (PEI) at pH 8.65 and a multilayer polymer coated capillary, lactate could be resolved from other compounds present in media with relative standard deviations 0.07% for intraday electrophoretic mobility and an analysis time of less than 10min. Using the human embryonic kidney cell line HEK293, lactate concentrations in the cell culture medium were measured every 20min over 3 days, requiring only 8.73μL of sample per run. Combining simplicity, portability, automation, high sample throughput, low limits of detection, low sample consumption and the ability to up- and outscale, this new methodology represents a promising technique for near real-time monitoring of chemical changes in diverse cell culture applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Sequential cloud-point extraction for toxicological screening analysis of medicaments in human plasma by high pressure liquid chromatography with diode array detector.

    Science.gov (United States)

    Madej, Katarzyna; Persona, Karolina; Wandas, Monika; Gomółka, Ewa

    2013-10-18

    A complex extraction system with the use of cloud-point extraction technique (CPE) was developed for sequential isolation of basic and acidic/neutral medicaments from human plasma/serum, screened by HPLC/DAD method. Eight model drugs (paracetamol, promazine, chlorpromazine, amitriptyline, salicyclic acid, opipramol, alprazolam and carbamazepine) were chosen for the study of optimal CPE conditions. The CPE technique consists in partition of an aqueous sample with addition of a surfactant into two phases: micelle-rich phase with the isolated compounds and water phase containing a surfactant below the critical micellar concentration, mainly under influence of temperature change. The proposed extraction system consists of two chief steps: isolation of basic compounds (from pH 12) and then isolation of acidic/neutral compounds (from pH 6) using surfactant Triton X-114 as the extraction medium. Extraction recovery varied from 25.2 to 107.9% with intra-day and inter-day precision (RSD %) ranged 0.88-1087 and 5.32-17.96, respectively. The limits of detection for the studied medicaments at λ 254nm corresponded to therapeutic or low toxic plasma concentration levels. Usefulness of the proposed CPE-HPLC/DAD method for toxicological drug screening was tested via its application to analysis of two serum samples taken from patients suspected of drug overdosing. Published by Elsevier B.V.

  9. Inflection point inflation and time dependent potentials in string theory

    International Nuclear Information System (INIS)

    Itzhaki, Nissan; Kovetz, Ely D.

    2007-01-01

    We consider models of inflection point inflation. The main drawback of such models is that they suffer from the overshoot problem. Namely the initial condition should be fine tuned to be near the inflection point for the universe to inflate. We show that stringy realizations of inflection point inflation are common and offer a natural resolution to the overshoot problem

  10. Time-sequential observation of spindle and phragmoplast orientation in BY-2 cells with altered cortical actin microfilament patterning.

    Science.gov (United States)

    Kojo, Kei H; Yasuhara, Hiroki; Hasezawa, Seiichiro

    2014-01-01

    Precise division plane determination is essential for plant development. At metaphase, a dense actin microfilament meshwork appears on both sides of the cell center, forming a characteristic cortical actin microfilament twin peak pattern in BY-2 cells. We previously reported a strong correlation between altered cortical actin microfilament patterning and an oblique mitotic spindle orientation, implying that these actin microfilament twin peaks play a role in the regulation of mitotic spindle orientation. In the present study, time-sequential observation was used to reveal the progression from oblique phragmoplast to oblique cell plate orientation in cells with altered cortical actin microfilament patterning. In contrast to cells with normal actin microfilament twin peaks, oblique phragmoplast reorientation was rarely observed in cells with altered cortical actin microfilament patterning. These results support the important roles of cortical actin microfilament patterning in division plane orientation.

  11. Sequential Specification of Time-aware Stream Processing Applications (Extended Abstract)

    NARCIS (Netherlands)

    Geuns, S.J.; Hausmans, J.P.H.M.; Bekooij, Marco Jan Gerrit

    2012-01-01

    Automatic parallelization of Nested Loop Programs (NLPs) is an attractive method to create embedded real-time stream processing applications for multi-core systems. However, the description and parallelization of applications with a time dependent functional behavior has not been considered in NLPs.

  12. Time optimization of 90Sr measurements: Sequential measurement of multiple samples during ingrowth of 90Y

    International Nuclear Information System (INIS)

    Holmgren, Stina; Tovedal, Annika; Björnham, Oscar; Ramebäck, Henrik

    2016-01-01

    The aim of this paper is to contribute to a more rapid determination of a series of samples containing 90 Sr by making the Cherenkov measurement of the daughter nuclide 90 Y more time efficient. There are many instances when an optimization of the measurement method might be favorable, such as; situations requiring rapid results in order to make urgent decisions or, on the other hand, to maximize the throughput of samples in a limited available time span. In order to minimize the total analysis time, a mathematical model was developed which calculates the time of ingrowth as well as individual measurement times for n samples in a series. This work is focused on the measurement of 90 Y during ingrowth, after an initial chemical separation of strontium, in which it is assumed that no other radioactive strontium isotopes are present. By using a fixed minimum detectable activity (MDA) and iterating the measurement time for each consecutive sample the total analysis time will be less, compared to using the same measurement time for all samples. It was found that by optimization, the total analysis time for 10 samples can be decreased greatly, from 21 h to 6.5 h, when assuming a MDA of 1 Bq/L and at a background count rate of approximately 0.8 cpm. - Highlights: • An approach roughly a factor of three more efficient than an un-optimized method. • The optimization gives a more efficient use of instrument time. • The efficiency increase ranges from a factor of three to 10, for 10 to 40 samples.

  13. Modelling point patterns with linear structures

    DEFF Research Database (Denmark)

    Møller, Jesper; Rasmussen, Jakob Gulddahl

    2009-01-01

    processes whose realizations contain such linear structures. Such a point process is constructed sequentially by placing one point at a time. The points are placed in such a way that new points are often placed close to previously placed points, and the points form roughly line shaped structures. We...... consider simulations of this model and compare with real data....

  14. Modelling point patterns with linear structures

    DEFF Research Database (Denmark)

    Møller, Jesper; Rasmussen, Jakob Gulddahl

    processes whose realizations contain such linear structures. Such a point process is constructed sequentially by placing one point at a time. The points are placed in such a way that new points are often placed close to previously placed points, and the points form roughly line shaped structures. We...... consider simulations of this model and compare with real data....

  15. Observation of environmental radioactivity at definite time and definite point

    International Nuclear Information System (INIS)

    Inokoshi, Yukio; Fukuchi, Ryoichi; Irie, Takayuki; Hosoda, Nagako; Okano, Yasuhiro; Shindo, Koutaro

    1990-01-01

    The measurement of environmental radioactivity in Tokyo Metropolis was carried out. The objects of measurement were rainwater, atmospheric floating dusts, spatial dose and the activated sludge in sewage treatment plants. Rainwater, atmospheric floating dusts and spatial dose were analyzed mainly considering radioactive fallout, and activated sludge was analyzed mainly considering radioactive medical matters. For the analysis of nuclides, a Ge(Li) semiconductor detector was used, and spatial dose rate was measured with a DBM type dose rate meter. In activated sludge, the nuclides used for radioactive medicines were found, but in rainwater, atmospheric floating dusts and spatial dose, particular abnormality was not found. The objective of this investigation is to collect over long period at definite time and definite points the data on environmental radioactivity in Tokyo, thus to grasp the level of normal values, and in abnormal case, to clarify the cause and to evaluate the exposure dose. The instruments used, the method of measuring each object and the results are reported. (K.I.)

  16. Sequential processing of quantitative phase images for the study of cell behaviour in real-time digital holographic microscopy.

    Science.gov (United States)

    Zikmund, T; Kvasnica, L; Týč, M; Křížová, A; Colláková, J; Chmelík, R

    2014-11-01

    Transmitted light holographic microscopy is particularly used for quantitative phase imaging of transparent microscopic objects such as living cells. The study of the cell is based on extraction of the dynamic data on cell behaviour from the time-lapse sequence of the phase images. However, the phase images are affected by the phase aberrations that make the analysis particularly difficult. This is because the phase deformation is prone to change during long-term experiments. Here, we present a novel algorithm for sequential processing of living cells phase images in a time-lapse sequence. The algorithm compensates for the deformation of a phase image using weighted least-squares surface fitting. Moreover, it identifies and segments the individual cells in the phase image. All these procedures are performed automatically and applied immediately after obtaining every single phase image. This property of the algorithm is important for real-time cell quantitative phase imaging and instantaneous control of the course of the experiment by playback of the recorded sequence up to actual time. Such operator's intervention is a forerunner of process automation derived from image analysis. The efficiency of the propounded algorithm is demonstrated on images of rat fibrosarcoma cells using an off-axis holographic microscope. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  17. Sequential double excitations from linear-response time-dependent density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Mosquera, Martín A.; Ratner, Mark A.; Schatz, George C., E-mail: g-schatz@northwestern.edu [Department of Chemistry, Northwestern University, 2145 Sheridan Rd., Evanston, Illinois 60208 (United States); Chen, Lin X. [Department of Chemistry, Northwestern University, 2145 Sheridan Rd., Evanston, Illinois 60208 (United States); Chemical Sciences and Engineering Division, Argonne National Laboratory, 9700 South Cass Ave., Lemont, Illinois 60439 (United States)

    2016-05-28

    Traditional UV/vis and X-ray spectroscopies focus mainly on the study of excitations starting exclusively from electronic ground states. However there are many experiments where transitions from excited states, both absorption and emission, are probed. In this work we develop a formalism based on linear-response time-dependent density functional theory to investigate spectroscopic properties of excited states. We apply our model to study the excited-state absorption of a diplatinum(II) complex under X-rays, and transient vis/UV absorption of pyrene and azobenzene.

  18. Sequential hand hygiene promotion contributes to a reduced nosocomial bloodstream infection rate among very low-birth weight infants: an interrupted time series over a 10-year period

    NARCIS (Netherlands)

    Helder, Onno K.; Brug, Johannes; van Goudoever, Johannes B.; Looman, Caspar W. N.; Reiss, Irwin K. M.; Kornelisse, René F.

    2014-01-01

    Sustained high compliance with hand hygiene (HH) is needed to reduce nosocomial bloodstream infections (NBSIs). However, over time, a wash out effect often occurs. We studied the long-term effect of sequential HH-promoting interventions. An observational study with an interrupted time series

  19. Dual time point FDG-PET/CT imaging...; Potential tool for diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Zytoon, A.A.; Murakami, K.; El-Kholy, M.R.; El-Shorbagy, E.

    2008-01-01

    Aim: This prospective study was designed to assess the utility of the dual time point imaging technique using 2- [ 18 F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography/computed tomography (PET/CT) to detect primary breast cancer and to determine whether it is useful for the detection of small and non-invasive cancers, as well as cancers in dense breast tissue. Methods: One hundred and eleven patients with newly diagnosed breast cancer underwent two sequential PET/CT examinations (dual time point imaging) for preoperative staging. The maximum standardized uptake value (SUVmax) of FDG was measured from both time points. The percentage change in SUVmax (ΔSUVmax%) between time points 1 (SUVmax1) and 2 (SUVmax2) was calculated. The patients were divided into groups: invasive (n = 82), non invasive (n = 29); large (>10 mm; n = 80), small (≤10 mm; n = 31); tumours in dense breasts (n = 61), and tumours in non-dense breasts (n = 50). The tumour:background (T:B) ratios at both time points were measured and the ΔSUVmax%, ΔT:B% values were calculated. All PET study results were correlated with the histopathology results. Results: Of the 111 cancer lesions, 88 (79.3%) showed an increase and 23 (20.7%) showed either no change [10 (9%)] or a decrease [13 (11.7%)] in the SUVmax over time. Of the 111 contralateral normal breasts, nine (8.1%) showed an increase and 102 (91.9%) showed either no change [17 (15.3%)] or a decrease [85 (76.6%)] in the SUVmax over time. The mean ± SD of SUVmax1, SUVmax2, Δ%SUVmax were 4.9 ± 3.6, 6.0 ± 4.5, and 22.6 ± 13.1% for invasive cancers, 4.1 ± 3.8, 4.4 ± 4.8, and -2.4 ± 18.5% for non-invasive cancers, 2.3 ± 1.9, 2.7 ± 2.3, and 12.9 ± 21.1% for small cancers, 5.6 ± 3.7, 6.8 ± 4.8, and 17.3 ± 17.1% for large cancers, 4.9 ± 3.7, 5.8 ± 4.8, and 15.1 ± 17.6% for cancers in dense breast, and 4.5 ± 3.6, 5.4 ± 4.5, and 17.2 ± 19.2% for cancers in non-dense breast. The receiver-operating characteristic (ROC) analysis

  20. Predicting the Location and Time of Mobile Phone Users by Using Sequential Pattern Mining Techniques

    DEFF Research Database (Denmark)

    Ozer, Mert; Keles, Ilkcan; Toroslu, Hakki

    2016-01-01

    In recent years, using cell phone log data to model human mobility patterns became an active research area. This problem is a challenging data mining problem due to huge size and non-uniformity of the log data, which introduces several granularity levels for the specification of temporal...... and spatial dimensions. This paper focuses on the prediction of the location of the next activity of the mobile phone users. There are several versions of this problem. In this work, we have concentrated on the following three problems: predicting the location and the time of the next user activity...... the success of these methods with real data obtained from one of the largest mobile phone operators in Turkey. Our results are very encouraging, since we were able to obtain quite high accuracy results under small prediction sets....

  1. Age, time period, and birth cohort differences in self-esteem: Reexamining a cohort-sequential longitudinal study.

    Science.gov (United States)

    Twenge, Jean M; Carter, Nathan T; Campbell, W Keith

    2017-05-01

    Orth, Trzesniewski, and Robins (2010) concluded that the nationally representative Americans' Changing Lives (ACL) cohort-sequential study demonstrated moderate to large age differences in self-esteem, and no birth cohort (generational) differences in the age trajectory. In a reanalysis of these data using 2 different statistical techniques, we find significant increases in self-esteem that could be attributed to birth cohort or time period. First, hierarchical linear modeling analyses with birth cohort as a continuous variable (vs. the multiple group formulation used by Orth et al.) find that birth cohort has a measurable influence on self-esteem through its interaction with age. Participants born in later years (e.g., 1960) were higher in self-esteem and were more likely to increase in self-esteem as they aged than participants born in earlier years (e.g., 1920). However, the estimated age trajectory up to age 60 is similar in Orth et al.'s results and in the results from our analyses including cohort. Second, comparing ACL respondents of the same age in 1986 versus 2002 (a time-lag design) yields significant birth cohort differences in self-esteem, with 2002 participants of the same age higher in self-esteem than those in 1986. Combined with some previous studies finding significant increases in self-esteem and positive self-views over time, these results suggest that cultural change in the form of cohort and time period cannot be ignored as influences in cross-sectional and longitudinal studies. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  2. Sequential hand hygiene promotion contributes to a reduced nosocomial bloodstream infection rate among very low-birth weight infants: An interrupted time series over a 10-year period

    NARCIS (Netherlands)

    Helder, O.K.; Brug, J.; van Goudoever, J.B.; Looman, C.W.N.; Reiss, I.K.M.; Kornelisse, R.F.

    2014-01-01

    Background Sustained high compliance with hand hygiene (HH) is needed to reduce nosocomial bloodstream infections (NBSIs). However, over time, a wash out effect often occurs. We studied the long-term effect of sequential HH-promoting interventions. Methods An observational study with an interrupted

  3. Administrative Lead Time at Navy Inventory Control Points

    National Research Council Canada - National Science Library

    Granetto, Paul

    1994-01-01

    .... We also evaluated the internal controls established for administrative lead time and the adequacy of management's implementation of the DoD Internal Management Control Program for monitoring administrative lead time...

  4. Point-like Particles in Fuzzy Space-time

    OpenAIRE

    Francis, Charles

    1999-01-01

    This paper is withdrawn as I am no longer using the term "fuzzy space- time" to describe the uncertainty in co-ordinate systems implicit in quantum logic. Nor am I using the interpretation that quantum logic can be regarded as a special case of fuzzy logic. This is because there are sufficient differences between quantum logic and fuzzy logic that the explanation is confusing. I give an interpretation of quantum logic in "A Theory of Quantum Space-time"

  5. Sequential injection analysis for automation of the Winkler methodology, with real-time SIMPLEX optimization and shipboard application

    Energy Technology Data Exchange (ETDEWEB)

    Horstkotte, Burkhard; Tovar Sanchez, Antonio; Duarte, Carlos M. [Department of Global Change Research, IMEDEA (CSIC-UIB) Institut Mediterrani d' Estudis Avancats, Miquel Marques 21, 07190 Esporles (Spain); Cerda, Victor, E-mail: Victor.Cerda@uib.es [University of the Balearic Islands, Department of Chemistry Carreterra de Valldemossa km 7.5, 07011 Palma de Mallorca (Spain)

    2010-01-25

    A multipurpose analyzer system based on sequential injection analysis (SIA) for the determination of dissolved oxygen (DO) in seawater is presented. Three operation modes were established and successfully applied onboard during a research cruise in the Southern ocean: 1st, in-line execution of the entire Winkler method including precipitation of manganese (II) hydroxide, fixation of DO, precipitate dissolution by confluent acidification, and spectrophotometric quantification of the generated iodine/tri-iodide (I{sub 2}/I{sub 3}{sup -}), 2nd, spectrophotometric quantification of I{sub 2}/I{sub 3}{sup -} in samples prepared according the classical Winkler protocol, and 3rd, accurate batch-wise titration of I{sub 2}/I{sub 3}{sup -} with thiosulfate using one syringe pump of the analyzer as automatic burette. In the first mode, the zone stacking principle was applied to achieve high dispersion of the reagent solutions in the sample zone. Spectrophotometric detection was done at the isobestic wavelength 466 nm of I{sub 2}/I{sub 3}{sup -}. Highly reduced consumption of reagents and sample compared to the classical Winkler protocol, linear response up to 16 mg L{sup -1} DO, and an injection frequency of 30 per hour were achieved. It is noteworthy that for the offline protocol, sample metering and quantification with a potentiometric titrator lasts in general over 5 min without counting sample fixation, incubation, and glassware cleaning. The modified SIMPLEX methodology was used for the simultaneous optimization of four volumetric and two chemical variables. Vertex calculation and consequent application including in-line preparation of one reagent was carried out in real-time using the software AutoAnalysis. The analytical system featured high signal stability, robustness, and a repeatability of 3% RSD (1st mode) and 0.8% (2nd mode) during shipboard application.

  6. Sequential injection analysis for automation of the Winkler methodology, with real-time SIMPLEX optimization and shipboard application

    International Nuclear Information System (INIS)

    Horstkotte, Burkhard; Tovar Sanchez, Antonio; Duarte, Carlos M.; Cerda, Victor

    2010-01-01

    A multipurpose analyzer system based on sequential injection analysis (SIA) for the determination of dissolved oxygen (DO) in seawater is presented. Three operation modes were established and successfully applied onboard during a research cruise in the Southern ocean: 1st, in-line execution of the entire Winkler method including precipitation of manganese (II) hydroxide, fixation of DO, precipitate dissolution by confluent acidification, and spectrophotometric quantification of the generated iodine/tri-iodide (I 2 /I 3 - ), 2nd, spectrophotometric quantification of I 2 /I 3 - in samples prepared according the classical Winkler protocol, and 3rd, accurate batch-wise titration of I 2 /I 3 - with thiosulfate using one syringe pump of the analyzer as automatic burette. In the first mode, the zone stacking principle was applied to achieve high dispersion of the reagent solutions in the sample zone. Spectrophotometric detection was done at the isobestic wavelength 466 nm of I 2 /I 3 - . Highly reduced consumption of reagents and sample compared to the classical Winkler protocol, linear response up to 16 mg L -1 DO, and an injection frequency of 30 per hour were achieved. It is noteworthy that for the offline protocol, sample metering and quantification with a potentiometric titrator lasts in general over 5 min without counting sample fixation, incubation, and glassware cleaning. The modified SIMPLEX methodology was used for the simultaneous optimization of four volumetric and two chemical variables. Vertex calculation and consequent application including in-line preparation of one reagent was carried out in real-time using the software AutoAnalysis. The analytical system featured high signal stability, robustness, and a repeatability of 3% RSD (1st mode) and 0.8% (2nd mode) during shipboard application.

  7. Just-In-Time Inventory: Proceed with caution exclamation point

    International Nuclear Information System (INIS)

    Katterhenry, W.E.

    1995-01-01

    Today's economic climate, the emerging of independent power producers, pending deregulation, and environmental restraints are forcing the utility industry to adopt cost cutting measures in an effort to be more competitive and survive in tomorrow's market place. The cost cutting measure addressed in this paper is ''Just-In-Time Inventory'' of coal for fossil fueled power plants

  8. Simultaneous comparisons of treatments at multiple time points

    DEFF Research Database (Denmark)

    Pallmann, Philip; Pretorius, Mias; Ritz, Christian

    2017-01-01

    that is measured repeatedly over time and contrast two basic modeling strategies: fitting a joint model across all occasions (with random effects and/or some residual covariance structure to account for heteroscedasticity and serial dependence), and a novel approach combining a set of simple marginal, i...

  9. Sequential Banking.

    OpenAIRE

    Bizer, David S; DeMarzo, Peter M

    1992-01-01

    The authors study environments in which agents may borrow sequentially from more than one leader. Although debt is prioritized, additional lending imposes an externality on prior debt because, with moral hazard, the probability of repayment of prior loans decreases. Equilibrium interest rates are higher than they would be if borrowers could commit to borrow from at most one bank. Even though the loan terms are less favorable than they would be under commitment, the indebtedness of borrowers i...

  10. Sequential memory: Binding dynamics

    Science.gov (United States)

    Afraimovich, Valentin; Gong, Xue; Rabinovich, Mikhail

    2015-10-01

    Temporal order memories are critical for everyday animal and human functioning. Experiments and our own experience show that the binding or association of various features of an event together and the maintaining of multimodality events in sequential order are the key components of any sequential memories—episodic, semantic, working, etc. We study a robustness of binding sequential dynamics based on our previously introduced model in the form of generalized Lotka-Volterra equations. In the phase space of the model, there exists a multi-dimensional binding heteroclinic network consisting of saddle equilibrium points and heteroclinic trajectories joining them. We prove here the robustness of the binding sequential dynamics, i.e., the feasibility phenomenon for coupled heteroclinic networks: for each collection of successive heteroclinic trajectories inside the unified networks, there is an open set of initial points such that the trajectory going through each of them follows the prescribed collection staying in a small neighborhood of it. We show also that the symbolic complexity function of the system restricted to this neighborhood is a polynomial of degree L - 1, where L is the number of modalities.

  11. Sequential series for nuclear reactions

    International Nuclear Information System (INIS)

    Izumo, Ko

    1975-01-01

    A new time-dependent treatment of nuclear reactions is given, in which the wave function of compound nucleus is expanded by a sequential series of the reaction processes. The wave functions of the sequential series form another complete set of compound nucleus at the limit Δt→0. It is pointed out that the wave function is characterized by the quantities: the number of degrees of freedom of motion n, the period of the motion (Poincare cycle) tsub(n), the delay time t sub(nμ) and the relaxation time tausub(n) to the equilibrium of compound nucleus, instead of the usual quantum number lambda, the energy eigenvalue Esub(lambda) and the total width GAMMAsub(lambda) of resonance levels, respectively. The transition matrix elements and the yields of nuclear reactions also become the functions of time given by the Fourier transform of the usual ones. The Poincare cycles of compound nuclei are compared with the observed correlations among resonance levels, which are about 10 -17 --10 -16 sec for medium and heavy nuclei and about 10 -20 sec for the intermediate resonances. (auth.)

  12. Dual time point 18FDG-PET/CT versus single time point 18FDG-PET/CT for the differential diagnosis of pulmonary nodules - A meta-analysis

    International Nuclear Information System (INIS)

    Zhang, Li; Wang, Yinzhong; Lei, Junqiang; Tian, Jinhui; Zhai, Yanan

    2013-01-01

    Background: Lung cancer is one of the most common cancer types in the world. An accurate diagnosis of lung cancer is crucial for early treatment and management. Purpose: To perform a comprehensive meta-analysis to evaluate the diagnostic performance of dual time point 18F-fluorodexyglucose position emission tomography/computed tomography (FDG-PET/CT) and single time point 18FDG-PET/CT in the diagnosis of pulmonary nodules. Material and Methods: PubMed (1966-2011.11), EMBASE (1974-2011.11), Web of Science (1972-2011.11), Cochrane Library (-2011.11), and four Chinese databases; CBM (1978-2011.11), CNKI (1994-2011.11), VIP (1989-2011.11), and Wanfang Database (1994-2011.11) were searched. Summary sensitivity, summary specificity, summary diagnostic odds ratios (DOR), and summary positive likelihood ratios (LR+) and negative likelihood ratios (LR-) were obtained using Meta-Disc software. Summary receiver-operating characteristic (SROC) curves were used to evaluate the diagnostic performance of dual time point 18FDG-PET/CT and single time point 18FDG-PET/CT. Results: The inclusion criteria were fulfilled by eight articles, with a total of 415 patients and 430 pulmonary nodules. Compared with the gold standard (pathology or clinical follow-up), the summary sensitivity of dual time point 18FDG-PET/CT was 79% (95%CI, 74.0 - 84.0%), and its summary specificity was 73% (95%CI, 65.0-79.0%); the summary LR+ was 2.61 (95%CI, 1.96-3.47), and the summary LR- was 0.29 (95%CI, 0.21 - 0.41); the summary DOR was 10.25 (95%CI, 5.79 - 18.14), and the area under the SROC curve (AUC) was 0.8244. The summary sensitivity for single time point 18FDG-PET/CT was 77% (95%CI, 71.9 - 82.3%), and its summary specificity was 59% (95%CI, 50.6 - 66.2%); the summary LR+ was 1.97 (95%CI, 1.32 - 2.93), and the summary LR- was 0.37 (95%CI, 0.29 - 0.49); the summary DOR was 6.39 (95%CI, 3.39 - 12.05), and the AUC was 0.8220. Conclusion: The results indicate that dual time point 18FDG-PET/CT and single

  13. LiDAR-IMU Time Delay Calibration Based on Iterative Closest Point and Iterated Sigma Point Kalman Filter.

    Science.gov (United States)

    Liu, Wanli

    2017-03-08

    The time delay calibration between Light Detection and Ranging (LiDAR) and Inertial Measurement Units (IMUs) is an essential prerequisite for its applications. However, the correspondences between LiDAR and IMU measurements are usually unknown, and thus cannot be computed directly for the time delay calibration. In order to solve the problem of LiDAR-IMU time delay calibration, this paper presents a fusion method based on iterative closest point (ICP) and iterated sigma point Kalman filter (ISPKF), which combines the advantages of ICP and ISPKF. The ICP algorithm can precisely determine the unknown transformation between LiDAR-IMU; and the ISPKF algorithm can optimally estimate the time delay calibration parameters. First of all, the coordinate transformation from the LiDAR frame to the IMU frame is realized. Second, the measurement model and time delay error model of LiDAR and IMU are established. Third, the methodology of the ICP and ISPKF procedure is presented for LiDAR-IMU time delay calibration. Experimental results are presented that validate the proposed method and demonstrate the time delay error can be accurately calibrated.

  14. Sequential Dependencies in Driving

    Science.gov (United States)

    Doshi, Anup; Tran, Cuong; Wilder, Matthew H.; Mozer, Michael C.; Trivedi, Mohan M.

    2012-01-01

    The effect of recent experience on current behavior has been studied extensively in simple laboratory tasks. We explore the nature of sequential effects in the more naturalistic setting of automobile driving. Driving is a safety-critical task in which delayed response times may have severe consequences. Using a realistic driving simulator, we find…

  15. Quantum Inequalities and Sequential Measurements

    International Nuclear Information System (INIS)

    Candelpergher, B.; Grandouz, T.; Rubinx, J.L.

    2011-01-01

    In this article, the peculiar context of sequential measurements is chosen in order to analyze the quantum specificity in the two most famous examples of Heisenberg and Bell inequalities: Results are found at some interesting variance with customary textbook materials, where the context of initial state re-initialization is described. A key-point of the analysis is the possibility of defining Joint Probability Distributions for sequential random variables associated to quantum operators. Within the sequential context, it is shown that Joint Probability Distributions can be defined in situations where not all of the quantum operators (corresponding to random variables) do commute two by two. (authors)

  16. Operational reliability evaluation of restructured power systems with wind power penetration utilizing reliability network equivalent and time-sequential simulation approaches

    DEFF Research Database (Denmark)

    Ding, Yi; Cheng, Lin; Zhang, Yonghong

    2014-01-01

    In the last two decades, the wind power generation has been rapidly and widely developed in many regions and countries for tackling the problems of environmental pollution and sustainability of energy supply. However, the high share of intermittent and fluctuating wind power production has also...... and reserve provides, fast reserve providers and transmission network in restructured power systems. A contingency management schema for real time operation considering its coupling with the day-ahead market is proposed. The time-sequential Monte Carlo simulation is used to model the chronological...

  17. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.; Shamma, Jeff S.

    2014-01-01

    incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well

  18. A real-time comparison between direct control, sequential pattern recognition control and simultaneous pattern recognition control using a Fitts' law style assessment procedure.

    Science.gov (United States)

    Wurth, Sophie M; Hargrove, Levi J

    2014-05-30

    Pattern recognition (PR) based strategies for the control of myoelectric upper limb prostheses are generally evaluated through offline classification accuracy, which is an admittedly useful metric, but insufficient to discuss functional performance in real time. Existing functional tests are extensive to set up and most fail to provide a challenging, objective framework to assess the strategy performance in real time. Nine able-bodied and two amputee subjects gave informed consent and participated in the local Institutional Review Board approved study. We designed a two-dimensional target acquisition task, based on the principles of Fitts' law for human motor control. Subjects were prompted to steer a cursor from the screen center of into a series of subsequently appearing targets of different difficulties. Three cursor control systems were tested, corresponding to three electromyography-based prosthetic control strategies: 1) amplitude-based direct control (the clinical standard of care), 2) sequential PR control, and 3) simultaneous PR control, allowing for a concurrent activation of two degrees of freedom (DOF). We computed throughput (bits/second), path efficiency (%), reaction time (second), and overshoot (%)) and used general linear models to assess significant differences between the strategies for each metric. We validated the proposed methodology by achieving very high coefficients of determination for Fitts' law. Both PR strategies significantly outperformed direct control in two-DOF targets and were more intuitive to operate. In one-DOF targets, the simultaneous approach was the least precise. The direct control was efficient in one-DOF targets but cumbersome to operate in two-DOF targets through a switch-depended sequential cursor control. We designed a test, capable of comprehensively describing prosthetic control strategies in real time. When implemented on control subjects, the test was able to capture statistically significant differences (p

  19. Evaluation of 2-point, 3-point, and 6-point Dixon magnetic resonance imaging with flexible echo timing for muscle fat quantification.

    Science.gov (United States)

    Grimm, Alexandra; Meyer, Heiko; Nickel, Marcel D; Nittka, Mathias; Raithel, Esther; Chaudry, Oliver; Friedberger, Andreas; Uder, Michael; Kemmler, Wolfgang; Quick, Harald H; Engelke, Klaus

    2018-06-01

    The purpose of this study is to evaluate and compare 2-point (2pt), 3-point (3pt), and 6-point (6pt) Dixon magnetic resonance imaging (MRI) sequences with flexible echo times (TE) to measure proton density fat fraction (PDFF) within muscles. Two subject groups were recruited (G1: 23 young and healthy men, 31 ± 6 years; G2: 50 elderly men, sarcopenic, 77 ± 5 years). A 3-T MRI system was used to perform Dixon imaging on the left thigh. PDFF was measured with six Dixon prototype sequences: 2pt, 3pt, and 6pt sequences once with optimal TEs (in- and opposed-phase echo times), lower resolution, and higher bandwidth (optTE sequences) and once with higher image resolution (highRes sequences) and shortest possible TE, respectively. Intra-fascia PDFF content was determined. To evaluate the comparability among the sequences, Bland-Altman analysis was performed. The highRes 6pt Dixon sequences served as reference as a high correlation of this sequence to magnetic resonance spectroscopy has been shown before. The PDFF difference between the highRes 6pt Dixon sequence and the optTE 6pt, both 3pt, and the optTE 2pt was low (between 2.2% and 4.4%), however, not to the highRes 2pt Dixon sequence (33%). For the optTE sequences, difference decreased with the number of echoes used. In conclusion, for Dixon sequences with more than two echoes, the fat fraction measurement was reliable with arbitrary echo times, while for 2pt Dixon sequences, it was reliable with dedicated in- and opposed-phase echo timing. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. A travel time forecasting model based on change-point detection method

    Science.gov (United States)

    LI, Shupeng; GUANG, Xiaoping; QIAN, Yongsheng; ZENG, Junwei

    2017-06-01

    Travel time parameters obtained from road traffic sensors data play an important role in traffic management practice. A travel time forecasting model is proposed for urban road traffic sensors data based on the method of change-point detection in this paper. The first-order differential operation is used for preprocessing over the actual loop data; a change-point detection algorithm is designed to classify the sequence of large number of travel time data items into several patterns; then a travel time forecasting model is established based on autoregressive integrated moving average (ARIMA) model. By computer simulation, different control parameters are chosen for adaptive change point search for travel time series, which is divided into several sections of similar state.Then linear weight function is used to fit travel time sequence and to forecast travel time. The results show that the model has high accuracy in travel time forecasting.

  1. Novel technique for prediction of time points for scheduling of multipurpose batch plants

    CSIR Research Space (South Africa)

    Seid, R

    2012-01-01

    Full Text Available . Consequently this avoids costly computational times due to iterations. In the model by Majozi and Zhu (2001) the sequence constraint that pertains to tasks that consume and produce the same state, the starting time of the consuming task at time point p must...

  2. Sequential Convex Programming for Power Set-point Optimization in a Wind Farm using Black-box Models, Simple Turbine Interactions, and Integer Variables

    DEFF Research Database (Denmark)

    Hovgaard, Tobias Gybel; Larsen, Lars F. S.; Jørgensen, John Bagterp

    2012-01-01

    We consider the optimization of power set-points to a large number of wind turbines arranged within close vicinity of each other in a wind farm. The goal is to maximize the total electric power extracted from the wind, taking the wake effects that couple the individual turbines in the farm into a...... is far superior to, a more naive distribution scheme. We employ a fast convex quadratic programming solver to carry out the iterations in the range of microseconds for even large wind farms....

  3. Yeast Monitoring of Wine Mixed or Sequential Fermentations Made by Native Strains from D.O. “Vinos de Madrid” Using Real-Time Quantitative PCR

    Science.gov (United States)

    García, Margarita; Esteve-Zarzoso, Braulio; Crespo, Julia; Cabellos, Juan M.; Arroyo, Teresa

    2017-01-01

    There is an increasing trend toward understanding the impact of non-Saccharomyces yeasts on the winemaking process. Although Saccharomyces cerevisiae is the predominant species at the end of fermentation, it has been recognized that the presence of non-Saccharomyces species during alcoholic fermentation can produce an improvement in the quality and complexity of the final wines. A previous work was developed for selecting the best combinations between S. cerevisiae and five non-Saccharomyces (Torulaspora delbrueckii, Schizosaccharomyces pombe, Candida stellata, Metschnikowia pulcherrima, and Lachancea thermotolorans) native yeast strains from D.O. “Vinos de Madrid” at the laboratory scale. The best inoculation strategies between S. cerevisiae and non-Saccharomyces strains were chosen to analyze, by real-time quantitative PCR (qPCR) combined with the use of specific primers, the dynamics of inoculated populations throughout the fermentation process at the pilot scale using the Malvar white grape variety. The efficiency of the qPCR system was verified independently of the samples matrix, founding the inoculated yeast species throughout alcoholic fermentation. Finally, we can validate the positive effect of selected co-cultures in the Malvar wine quality, highlighting the sequential cultures of T. delbrueckii CLI 918/S. cerevisiae CLI 889 and C. stellata CLI 920/S. cerevisiae CLI 889 and, mixed and sequential cultures of L. thermotolerans 9-6C combined with S. cerevisiae CLI 889. PMID:29326669

  4. Yeast Monitoring of Wine Mixed or Sequential Fermentations Made by Native Strains from D.O. “Vinos de Madrid” Using Real-Time Quantitative PCR

    Directory of Open Access Journals (Sweden)

    Margarita García

    2017-12-01

    Full Text Available There is an increasing trend toward understanding the impact of non-Saccharomyces yeasts on the winemaking process. Although Saccharomyces cerevisiae is the predominant species at the end of fermentation, it has been recognized that the presence of non-Saccharomyces species during alcoholic fermentation can produce an improvement in the quality and complexity of the final wines. A previous work was developed for selecting the best combinations between S. cerevisiae and five non-Saccharomyces (Torulaspora delbrueckii, Schizosaccharomyces pombe, Candida stellata, Metschnikowia pulcherrima, and Lachancea thermotolorans native yeast strains from D.O. “Vinos de Madrid” at the laboratory scale. The best inoculation strategies between S. cerevisiae and non-Saccharomyces strains were chosen to analyze, by real-time quantitative PCR (qPCR combined with the use of specific primers, the dynamics of inoculated populations throughout the fermentation process at the pilot scale using the Malvar white grape variety. The efficiency of the qPCR system was verified independently of the samples matrix, founding the inoculated yeast species throughout alcoholic fermentation. Finally, we can validate the positive effect of selected co-cultures in the Malvar wine quality, highlighting the sequential cultures of T. delbrueckii CLI 918/S. cerevisiae CLI 889 and C. stellata CLI 920/S. cerevisiae CLI 889 and, mixed and sequential cultures of L. thermotolerans 9-6C combined with S. cerevisiae CLI 889.

  5. Sequential hand hygiene promotion contributes to a reduced nosocomial bloodstream infection rate among very low-birth weight infants: an interrupted time series over a 10-year period.

    Science.gov (United States)

    Helder, Onno K; Brug, Johannes; van Goudoever, Johannes B; Looman, Caspar W N; Reiss, Irwin K M; Kornelisse, René F

    2014-07-01

    Sustained high compliance with hand hygiene (HH) is needed to reduce nosocomial bloodstream infections (NBSIs). However, over time, a wash out effect often occurs. We studied the long-term effect of sequential HH-promoting interventions. An observational study with an interrupted time series analysis of the occurrence of NBSI was performed in very low-birth weight (VLBW) infants. Interventions consisted of an education program, gain-framed screen saver messages, and an infection prevention week with an introduction on consistent glove use. A total of 1,964 VLBW infants admitted between January 1, 2002, and December 31, 2011, were studied. The proportion of infants with ≥1 NBSI decreased from 47.6%-21.2% (P Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  6. Visualizing Robustness of Critical Points for 2D Time-Varying Vector Fields

    KAUST Repository

    Wang, B.

    2013-06-01

    Analyzing critical points and their temporal evolutions plays a crucial role in understanding the behavior of vector fields. A key challenge is to quantify the stability of critical points: more stable points may represent more important phenomena or vice versa. The topological notion of robustness is a tool which allows us to quantify rigorously the stability of each critical point. Intuitively, the robustness of a critical point is the minimum amount of perturbation necessary to cancel it within a local neighborhood, measured under an appropriate metric. In this paper, we introduce a new analysis and visualization framework which enables interactive exploration of robustness of critical points for both stationary and time-varying 2D vector fields. This framework allows the end-users, for the first time, to investigate how the stability of a critical point evolves over time. We show that this depends heavily on the global properties of the vector field and that structural changes can correspond to interesting behavior. We demonstrate the practicality of our theories and techniques on several datasets involving combustion and oceanic eddy simulations and obtain some key insights regarding their stable and unstable features. © 2013 The Author(s) Computer Graphics Forum © 2013 The Eurographics Association and Blackwell Publishing Ltd.

  7. Visualizing Robustness of Critical Points for 2D Time-Varying Vector Fields

    KAUST Repository

    Wang, B.; Rosen, P.; Skraba, P.; Bhatia, H.; Pascucci, V.

    2013-01-01

    Analyzing critical points and their temporal evolutions plays a crucial role in understanding the behavior of vector fields. A key challenge is to quantify the stability of critical points: more stable points may represent more important phenomena or vice versa. The topological notion of robustness is a tool which allows us to quantify rigorously the stability of each critical point. Intuitively, the robustness of a critical point is the minimum amount of perturbation necessary to cancel it within a local neighborhood, measured under an appropriate metric. In this paper, we introduce a new analysis and visualization framework which enables interactive exploration of robustness of critical points for both stationary and time-varying 2D vector fields. This framework allows the end-users, for the first time, to investigate how the stability of a critical point evolves over time. We show that this depends heavily on the global properties of the vector field and that structural changes can correspond to interesting behavior. We demonstrate the practicality of our theories and techniques on several datasets involving combustion and oceanic eddy simulations and obtain some key insights regarding their stable and unstable features. © 2013 The Author(s) Computer Graphics Forum © 2013 The Eurographics Association and Blackwell Publishing Ltd.

  8. Sequential Participation in a Multi-Institutional Mock Oral Examination Is Associated With Improved American Board of Surgery Certifying Examination First-Time Pass Rate.

    Science.gov (United States)

    Fingeret, Abbey L; Arnell, Tracey; McNelis, John; Statter, Mindy; Dresner, Lisa; Widmann, Warren

    We sought to determine whether sequential participation in a multi-institutional mock oral examination affected the likelihood of passing the American Board of Surgery Certifying Examination (ABSCE) in first attempt. Residents from 3 academic medical centers were able to participate in a regional mock oral examination in the fall and spring of their fourth and fifth postgraduate year from 2011 to 2014. Candidate׳s highest composite score of all mock orals attempts was classified as risk for failure, intermediate, or likely to pass. Factors including United States Medical Licensing Examination steps 1, 2, and 3, number of cases logged, American Board of Surgery In-Training Examination performance, American Board of Surgery Qualifying Examination (ABSQE) performance, number of attempts, and performance in the mock orals were assessed to determine factors predictive of passing the ABSCE. A total of 128 mock oral examinations were administered to 88 (71%) of 124 eligible residents. The overall first-time pass rate for the ABSCE was 82%. There was no difference in pass rates between participants and nonparticipants. Of them, 16 (18%) residents were classified as at risk, 47 (53%) as intermediate, and 25 (29%) as likely to pass. ABSCE pass rate for each group was as follows: 36% for at risk, 84% for intermediate, and 96% for likely pass. The following 4 factors were associated with first-time passing of ABSCE on bivariate analysis: mock orals participation in postgraduate year 4 (p = 0.05), sequential participation in mock orals (p = 0.03), ABSQE performance (p = 0.01), and best performance on mock orals (p = 0.001). In multivariable logistic regression, the following 3 factors remained associated with ABSCE passing: ABSQE performance, odds ratio (OR) = 2.9 (95% CI: 1.3-6.1); mock orals best performance, OR = 1.7 (1.2-2.4); and participation in multiple mock oral examinations, OR = 1.4 (1.1-2.7). Performance on a multi-institutional mock oral examination can identify

  9. Method to minimize the low-frequency neutral-point voltage oscillations with time-offset injection for neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Choi, Uimin; Lee, Kyo-Beum; Blaabjerg, Frede

    2013-01-01

    This paper proposes a method to reduce the low-frequency neutral-point voltage oscillations. The neutral-point voltage oscillations are considerably reduced by adding a time-offset to the three phase turn-on times. The proper time-offset is simply calculated considering the phase currents and dwell...

  10. Knee point search using cascading top-k sorting with minimized time complexity.

    Science.gov (United States)

    Wang, Zheng; Tseng, Shian-Shyong

    2013-01-01

    Anomaly detection systems and many other applications are frequently confronted with the problem of finding the largest knee point in the sorted curve for a set of unsorted points. This paper proposes an efficient knee point search algorithm with minimized time complexity using the cascading top-k sorting when a priori probability distribution of the knee point is known. First, a top-k sort algorithm is proposed based on a quicksort variation. We divide the knee point search problem into multiple steps. And in each step an optimization problem of the selection number k is solved, where the objective function is defined as the expected time cost. Because the expected time cost in one step is dependent on that of the afterwards steps, we simplify the optimization problem by minimizing the maximum expected time cost. The posterior probability of the largest knee point distribution and the other parameters are updated before solving the optimization problem in each step. An example of source detection of DNS DoS flooding attacks is provided to illustrate the applications of the proposed algorithm.

  11. Method to Minimize the Low-Frequency Neutral-Point Voltage Oscillations With Time-Offset Injection for Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Choi, Ui-Min; Blaabjerg, Frede; Lee, Kyo-Beum

    2015-01-01

    time of small- and medium-voltage vectors. However, if the power factor is lower, there is a limitation to eliminate neutral-point oscillations. In this case, the proposed method can be improved by changing the switching sequence properly. Additionally, a method for neutral-point voltage balancing......This paper proposes a method to reduce the low-frequency neutral-point voltage oscillations. The neutral-point voltage oscillations are considerably reduced by adding a time offset to the three-phase turn-on times. The proper time offset is simply calculated considering the phase currents and dwell...

  12. Farey Statistics in Time n^{2/3} and Counting Primitive Lattice Points in Polygons

    OpenAIRE

    Patrascu, Mihai

    2007-01-01

    We present algorithms for computing ranks and order statistics in the Farey sequence, taking time O (n^{2/3}). This improves on the recent algorithms of Pawlewicz [European Symp. Alg. 2007], running in time O (n^{3/4}). We also initiate the study of a more general algorithmic problem: counting primitive lattice points in planar shapes.

  13. Dual time-point FDG PET/CT for differentiating benign from ...

    African Journals Online (AJOL)

    Maximum standard uptake values (SUVmax) with the greatest uptake in the lesion were calculated for two time points (SUV1 and SUV2), and the percentage change over time per lesion was calculated (%DSUV). Routine histological findings served as the gold standard. Results. Histological examination showed that 14 ...

  14. Definition of distance for nonlinear time series analysis of marked point process data

    Energy Technology Data Exchange (ETDEWEB)

    Iwayama, Koji, E-mail: koji@sat.t.u-tokyo.ac.jp [Research Institute for Food and Agriculture, Ryukoku Univeristy, 1-5 Yokotani, Seta Oe-cho, Otsu-Shi, Shiga 520-2194 (Japan); Hirata, Yoshito; Aihara, Kazuyuki [Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505 (Japan)

    2017-01-30

    Marked point process data are time series of discrete events accompanied with some values, such as economic trades, earthquakes, and lightnings. A distance for marked point process data allows us to apply nonlinear time series analysis to such data. We propose a distance for marked point process data which can be calculated much faster than the existing distance when the number of marks is small. Furthermore, under some assumptions, the Kullback–Leibler divergences between posterior distributions for neighbors defined by this distance are small. We performed some numerical simulations showing that analysis based on the proposed distance is effective. - Highlights: • A new distance for marked point process data is proposed. • The distance can be computed fast enough for a small number of marks. • The method to optimize parameter values of the distance is also proposed. • Numerical simulations indicate that the analysis based on the distance is effective.

  15. Dynamic analysis of mental sweating of eccrine sweat gland of human fingertip by time-sequential piled-up en face optical coherence tomography images.

    Science.gov (United States)

    Ohmi, Masato; Wada, Yuki

    2016-08-01

    In this paper, we demonstrate dynamic analysis of mental sweating for sound stimulus of a few tens of eccrine sweat glands by the time-sequential piled-up en face optical coherence tomography (OCT) images with the frame spacing of 3.3 sec. In the experiment, the amount of excess sweat can be evaluated simultaneously for a few tens of sweat glands by piling up of all the en face OCT images. Non-uniformity was observed in mental sweating where the amount of sweat in response to sound stimulus is different for each sweat gland. Furthermore, the amount of sweat is significantly increased in proportion to the strength of the stimulus.

  16. Spatially heterogeneous dynamics investigated via a time-dependent four-point density correlation function

    DEFF Research Database (Denmark)

    Lacevic, N.; Starr, F. W.; Schrøder, Thomas

    2003-01-01

    correlation function g4(r,t) and corresponding "structure factor" S4(q,t) which measure the spatial correlations between the local liquid density at two points in space, each at two different times, and so are sensitive to dynamical heterogeneity. We study g4(r,t) and S4(q,t) via molecular dynamics......Relaxation in supercooled liquids above their glass transition and below the onset temperature of "slow" dynamics involves the correlated motion of neighboring particles. This correlated motion results in the appearance of spatially heterogeneous dynamics or "dynamical heterogeneity." Traditional...... two-point time-dependent density correlation functions, while providing information about the transient "caging" of particles on cooling, are unable to provide sufficiently detailed information about correlated motion and dynamical heterogeneity. Here, we study a four-point, time-dependent density...

  17. New Bounds of Ostrowski–Gruss Type Inequality for (k + 1 Points on Time Scales

    Directory of Open Access Journals (Sweden)

    Eze R. Nwaeze

    2017-11-01

    Full Text Available The aim of this paper is to present three new bounds of the Ostrowski--Gr\\"uss type inequality for points $x_0,x_1,x_2,\\cdots,x_k$ on time scales. Our results generalize result of Ng\\^o and Liu, and extend results of Ujevi\\'c to time scales with $(k+1$ points. We apply our results to the continuous, discrete, and quantum calculus to obtain many new interesting inequalities. An example is also considered. The estimates obtained in this paper will be very useful in numerical integration especially for the continuous case.

  18. Catch the wave! Time-window sequential analysis of alertness stimulation in individuals with profound intellectual and multiple disabilities

    NARCIS (Netherlands)

    Munde, V. S.; Vlaskamp, C.; Maes, B.; Ruijssenaars, A. J. J. M.

    BackgroundWhile optimally activities are provided at those moments when the individual with profound intellectual and multiple disabilities (PIMD) is focused on the environment' or alert', detailed information about the impact that the design and timing of the activity has on alertness is lacking.

  19. The Effect of 3D Virtual Reality on Sequential Time Perception among Deaf and Hard-of-Hearing Children

    Science.gov (United States)

    Eden, Sigal

    2008-01-01

    Over the years deaf and hard-of-hearing children have been reported as having difficulty with time conception and, in particular, the proper arrangement of events in a logical, temporal order. The research examined whether deaf and hard-of-hearing children perceive a temporal sequence differently under different representational modes. We compared…

  20. Synthetic Aperture Sequential Beamforming

    DEFF Research Database (Denmark)

    Kortbek, Jacob; Jensen, Jørgen Arendt; Gammelmark, Kim Løkke

    2008-01-01

    A synthetic aperture focusing (SAF) technique denoted Synthetic Aperture Sequential Beamforming (SASB) suitable for 2D and 3D imaging is presented. The technique differ from prior art of SAF in the sense that SAF is performed on pre-beamformed data contrary to channel data. The objective is to im......A synthetic aperture focusing (SAF) technique denoted Synthetic Aperture Sequential Beamforming (SASB) suitable for 2D and 3D imaging is presented. The technique differ from prior art of SAF in the sense that SAF is performed on pre-beamformed data contrary to channel data. The objective...... is to improve and obtain a more range independent lateral resolution compared to conventional dynamic receive focusing (DRF) without compromising frame rate. SASB is a two-stage procedure using two separate beamformers. First a set of Bmode image lines using a single focal point in both transmit and receive...... is stored. The second stage applies the focused image lines from the first stage as input data. The SASB method has been investigated using simulations in Field II and by off-line processing of data acquired with a commercial scanner. The performance of SASB with a static image object is compared with DRF...

  1. Computing Sequential Equilibria for Two-Player Games

    DEFF Research Database (Denmark)

    Miltersen, Peter Bro; Sørensen, Troels Bjerre

    2006-01-01

    Koller, Megiddo and von Stengel showed how to efficiently compute minimax strategies for two-player extensive-form zero-sum games with imperfect information but perfect recall using linear programming and avoiding conversion to normal form. Koller and Pfeffer pointed out that the strategies...... obtained by the algorithm are not necessarily sequentially rational and that this deficiency is often problematic for the practical applications. We show how to remove this deficiency by modifying the linear programs constructed by Koller, Megiddo and von Stengel so that pairs of strategies forming...... a sequential equilibrium are computed. In particular, we show that a sequential equilibrium for a two-player zero-sum game with imperfect information but perfect recall can be found in polynomial time. In addition, the equilibrium we find is normal-form perfect. Our technique generalizes to general-sum games...

  2. Selective, Embedded, Just-In-Time Specialization (SEJITS): Portable Parallel Performance from Sequential, Productive, Embedded Domain-Specific Languages

    Science.gov (United States)

    2012-12-01

    approaches to speaker diarization become fast enough to obviate further research in offline approaches. (We have not yet investigated what components of the...Evans, Corinne Fredouille, G Friedland, and O Vinyals. Speaker diarization : A review of recent research. Accepted for publication in ”IEEE Transactions...implementation from [32]. (b) Diarizer application performance as a multiple of real time; “100×” means that 1 second of audio can be processed in 1/100

  3. Time-dependent quantum transport through an interacting quantum dot beyond sequential tunneling: second-order quantum rate equations

    International Nuclear Information System (INIS)

    Dong, B; Ding, G H; Lei, X L

    2015-01-01

    A general theoretical formulation for the effect of a strong on-site Coulomb interaction on the time-dependent electron transport through a quantum dot under the influence of arbitrary time-varying bias voltages and/or external fields is presented, based on slave bosons and the Keldysh nonequilibrium Green's function (GF) techniques. To avoid the difficulties of computing double-time GFs, we generalize the propagation scheme recently developed by Croy and Saalmann to combine the auxiliary-mode expansion with the celebrated Lacroix's decoupling approximation in dealing with the second-order correlated GFs and then establish a closed set of coupled equations of motion, called second-order quantum rate equations (SOQREs), for an exact description of transient dynamics of electron correlated tunneling. We verify that the stationary solution of our SOQREs is able to correctly describe the Kondo effect on a qualitative level. Moreover, a comparison with other methods, such as the second-order von Neumann approach and Hubbard-I approximation, is performed. As illustrations, we investigate the transient current behaviors in response to a step voltage pulse and a harmonic driving voltage, and linear admittance as well, in the cotunneling regime. (paper)

  4. Empiric model for mean generation time adjustment factor for classic point kinetics equations

    Energy Technology Data Exchange (ETDEWEB)

    Goes, David A.B.V. de; Martinez, Aquilino S.; Goncalves, Alessandro da C., E-mail: david.goes@poli.ufrj.br, E-mail: aquilino@lmp.ufrj.br, E-mail: alessandro@con.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Departamento de Engenharia Nuclear

    2017-11-01

    Point reactor kinetics equations are the easiest way to observe the neutron production time behavior in a nuclear reactor. These equations are derived from the neutron transport equation using an approximation called Fick's law leading to a set of first order differential equations. The main objective of this study is to review classic point kinetics equation in order to approximate its results to the case when it is considered the time variation of the neutron currents. The computational modeling used for the calculations is based on the finite difference method. The results obtained with this model are compared with the reference model and then it is determined an empirical adjustment factor that modifies the point reactor kinetics equation to the real scenario. (author)

  5. Empiric model for mean generation time adjustment factor for classic point kinetics equations

    International Nuclear Information System (INIS)

    Goes, David A.B.V. de; Martinez, Aquilino S.; Goncalves, Alessandro da C.

    2017-01-01

    Point reactor kinetics equations are the easiest way to observe the neutron production time behavior in a nuclear reactor. These equations are derived from the neutron transport equation using an approximation called Fick's law leading to a set of first order differential equations. The main objective of this study is to review classic point kinetics equation in order to approximate its results to the case when it is considered the time variation of the neutron currents. The computational modeling used for the calculations is based on the finite difference method. The results obtained with this model are compared with the reference model and then it is determined an empirical adjustment factor that modifies the point reactor kinetics equation to the real scenario. (author)

  6. A point-based rendering approach for real-time interaction on mobile devices

    Institute of Scientific and Technical Information of China (English)

    LIANG XiaoHui; ZHAO QinPing; HE ZhiYing; XIE Ke; LIU YuBo

    2009-01-01

    Mobile device is an Important interactive platform. Due to the limitation of computation, memory, display area and energy, how to realize the efficient and real-time interaction of 3D models based on mobile devices is an important research topic. Considering features of mobile devices, this paper adopts remote rendering mode and point models, and then, proposes a transmission and rendering approach that could interact in real time. First, improved simplification algorithm based on MLS and display resolution of mobile devices is proposed. Then, a hierarchy selection of point models and a QoS transmission control strategy are given based on interest area of operator, interest degree of object in the virtual environment and rendering error. They can save the energy consumption. Finally, the rendering and interaction of point models are completed on mobile devices. The experiments show that our method is efficient.

  7. Bayesian inference for multivariate point processes observed at sparsely distributed times

    DEFF Research Database (Denmark)

    Rasmussen, Jakob Gulddahl; Møller, Jesper; Aukema, B.H.

    We consider statistical and computational aspects of simulation-based Bayesian inference for a multivariate point process which is only observed at sparsely distributed times. For specicity we consider a particular data set which has earlier been analyzed by a discrete time model involving unknown...... normalizing constants. We discuss the advantages and disadvantages of using continuous time processes compared to discrete time processes in the setting of the present paper as well as other spatial-temporal situations. Keywords: Bark beetle, conditional intensity, forest entomology, Markov chain Monte Carlo...

  8. A test of alternative estimators for volume at time 1 from remeasured point samples

    Science.gov (United States)

    Francis A. Roesch; Edwin J. Green; Charles T. Scott

    1993-01-01

    Two estimators for volume at time 1 for use with permanent horizontal point samples are evaluated. One estimator, used traditionally, uses only the trees sampled at time 1, while the second estimator, originally presented by Roesch and coauthors (F.A. Roesch, Jr., E.J. Green, and C.T. Scott. 1989. For. Sci. 35(2):281-293). takes advantage of additional sample...

  9. Computationally determining the salience of decision points for real-time wayfinding support

    Directory of Open Access Journals (Sweden)

    Makoto Takemiya

    2012-06-01

    Full Text Available This study introduces the concept of computational salience to explain the discriminatory efficacy of decision points, which in turn may have applications to providing real-time assistance to users of navigational aids. This research compared algorithms for calculating the computational salience of decision points and validated the results via three methods: high-salience decision points were used to classify wayfinders; salience scores were used to weight a conditional probabilistic scoring function for real-time wayfinder performance classification; and salience scores were correlated with wayfinding-performance metrics. As an exploratory step to linking computational and cognitive salience, a photograph-recognition experiment was conducted. Results reveal a distinction between algorithms useful for determining computational and cognitive saliences. For computational salience, information about the structural integration of decision points is effective, while information about the probability of decision-point traversal shows promise for determining cognitive salience. Limitations from only using structural information and motivations for future work that include non-structural information are elicited.

  10. Modified mean generation time parameter in the neutron point kinetics equations

    Energy Technology Data Exchange (ETDEWEB)

    Diniz, Rodrigo C.; Gonçalves, Alessandro C.; Rosa, Felipe S.S., E-mail: alessandro@nuclear.ufrj.br, E-mail: frosa@if.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    This paper proposes an approximation for the modified point kinetics equations proposed by NUNES et. al, 2015, through the adjustment of a kinetic parameter. This approximation consists of analyzing the terms of the modified point kinetics equations in order to identify the least important ones for the solution, resulting in a modification of the mean generation time parameter that incorporates all influences of the additional terms of the modified kinetics. This approximation is applied on the inverse kinetics, to compare the results with the inverse kinetics from the modified kinetics in order to validate the proposed model. (author)

  11. Modified mean generation time parameter in the neutron point kinetics equations

    International Nuclear Information System (INIS)

    Diniz, Rodrigo C.; Gonçalves, Alessandro C.; Rosa, Felipe S.S.

    2017-01-01

    This paper proposes an approximation for the modified point kinetics equations proposed by NUNES et. al, 2015, through the adjustment of a kinetic parameter. This approximation consists of analyzing the terms of the modified point kinetics equations in order to identify the least important ones for the solution, resulting in a modification of the mean generation time parameter that incorporates all influences of the additional terms of the modified kinetics. This approximation is applied on the inverse kinetics, to compare the results with the inverse kinetics from the modified kinetics in order to validate the proposed model. (author)

  12. Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

    Science.gov (United States)

    Arkin, C.; Gillespie, Stacey; Ratzel, Christopher

    2010-01-01

    A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

  13. Time discretization of the point kinetic equations using matrix exponential method and First-Order Hold

    International Nuclear Information System (INIS)

    Park, Yujin; Kazantzis, Nikolaos; Parlos, Alexander G.; Chong, Kil To

    2013-01-01

    Highlights: • Numerical solution for stiff differential equations using matrix exponential method. • The approximation is based on First Order Hold assumption. • Various input examples applied to the point kinetics equations. • The method shows superior useful and effective activity. - Abstract: A system of nonlinear differential equations is derived to model the dynamics of neutron density and the delayed neutron precursors within a point kinetics equation modeling framework for a nuclear reactor. The point kinetic equations are mathematically characterized as stiff, occasionally nonlinear, ordinary differential equations, posing significant challenges when numerical solutions are sought and traditionally resulting in the need for smaller time step intervals within various computational schemes. In light of the above realization, the present paper proposes a new discretization method inspired by system-theoretic notions and technically based on a combination of the matrix exponential method (MEM) and the First-Order Hold (FOH) assumption. Under the proposed time discretization structure, the sampled-data representation of the nonlinear point kinetic system of equations is derived. The performance of the proposed time discretization procedure is evaluated using several case studies with sinusoidal reactivity profiles and multiple input examples (reactivity and neutron source function). It is shown, that by applying the proposed method under a First-Order Hold for the neutron density and the precursor concentrations at each time step interval, the stiffness problem associated with the point kinetic equations can be adequately addressed and resolved. Finally, as evidenced by the aforementioned detailed simulation studies, the proposed method retains its validity and accuracy for a wide range of reactor operating conditions, including large sampling periods dictated by physical and/or technical limitations associated with the current state of sensor and

  14. Efficient constraint-based Sequential Pattern Mining (SPM algorithm to understand customers’ buying behaviour from time stamp-based sequence dataset

    Directory of Open Access Journals (Sweden)

    Niti Ashish Kumar Desai

    2015-12-01

    Full Text Available Business Strategies are formulated based on an understanding of customer needs. This requires development of a strategy to understand customer behaviour and buying patterns, both current and future. This involves understanding, first how an organization currently understands customer needs and second predicting future trends to drive growth. This article focuses on purchase trend of customer, where timing of purchase is more important than association of item to be purchased, and which can be found out with Sequential Pattern Mining (SPM methods. Conventional SPM algorithms worked purely on frequency identifying patterns that were more frequent but suffering from challenges like generation of huge number of uninteresting patterns, lack of user’s interested patterns, rare item problem, etc. Article attempts a solution through development of a SPM algorithm based on various constraints like Gap, Compactness, Item, Recency, Profitability and Length along with Frequency constraint. Incorporation of six additional constraints is as well to ensure that all patterns are recently active (Recency, active for certain time span (Compactness, profitable and indicative of next timeline for purchase (Length―Item―Gap. The article also attempts to throw light on how proposed Constraint-based Prefix Span algorithm is helpful to understand buying behaviour of customer which is in formative stage.

  15. Machine scheduling to minimize weighted completion times the use of the α-point

    CERN Document Server

    Gusmeroli, Nicoló

    2018-01-01

    This work reviews the most important results regarding the use of the α-point in Scheduling Theory. It provides a number of different LP-relaxations for scheduling problems and seeks to explain their polyhedral consequences. It also explains the concept of the α-point and how the conversion algorithm works, pointing out the relations to the sum of the weighted completion times. Lastly, the book explores the latest techniques used for many scheduling problems with different constraints, such as release dates, precedences, and parallel machines. This reference book is intended for advanced undergraduate and postgraduate students who are interested in scheduling theory. It is also inspiring for researchers wanting to learn about sophisticated techniques and open problems of the field.

  16. Time Series UAV Image-Based Point Clouds for Landslide Progression Evaluation Applications.

    Science.gov (United States)

    Al-Rawabdeh, Abdulla; Moussa, Adel; Foroutan, Marzieh; El-Sheimy, Naser; Habib, Ayman

    2017-10-18

    Landslides are major and constantly changing threats to urban landscapes and infrastructure. It is essential to detect and capture landslide changes regularly. Traditional methods for monitoring landslides are time-consuming, costly, dangerous, and the quality and quantity of the data is sometimes unable to meet the necessary requirements of geotechnical projects. This motivates the development of more automatic and efficient remote sensing approaches for landslide progression evaluation. Automatic change detection involving low-altitude unmanned aerial vehicle image-based point clouds, although proven, is relatively unexplored, and little research has been done in terms of accounting for volumetric changes. In this study, a methodology for automatically deriving change displacement rates, in a horizontal direction based on comparisons between extracted landslide scarps from multiple time periods, has been developed. Compared with the iterative closest projected point (ICPP) registration method, the developed method takes full advantage of automated geometric measuring, leading to fast processing. The proposed approach easily processes a large number of images from different epochs and enables the creation of registered image-based point clouds without the use of extensive ground control point information or further processing such as interpretation and image correlation. The produced results are promising for use in the field of landslide research.

  17. Meta-Analysis of Effect Sizes Reported at Multiple Time Points Using General Linear Mixed Model

    Science.gov (United States)

    Musekiwa, Alfred; Manda, Samuel O. M.; Mwambi, Henry G.; Chen, Ding-Geng

    2016-01-01

    Meta-analysis of longitudinal studies combines effect sizes measured at pre-determined time points. The most common approach involves performing separate univariate meta-analyses at individual time points. This simplistic approach ignores dependence between longitudinal effect sizes, which might result in less precise parameter estimates. In this paper, we show how to conduct a meta-analysis of longitudinal effect sizes where we contrast different covariance structures for dependence between effect sizes, both within and between studies. We propose new combinations of covariance structures for the dependence between effect size and utilize a practical example involving meta-analysis of 17 trials comparing postoperative treatments for a type of cancer, where survival is measured at 6, 12, 18 and 24 months post randomization. Although the results from this particular data set show the benefit of accounting for within-study serial correlation between effect sizes, simulations are required to confirm these results. PMID:27798661

  18. A method for untriggered time-dependent searches for multiple flares from neutrino point sources

    International Nuclear Information System (INIS)

    Gora, D.; Bernardini, E.; Cruz Silva, A.H.

    2011-04-01

    A method for a time-dependent search for flaring astrophysical sources which can be potentially detected by large neutrino experiments is presented. The method uses a time-clustering algorithm combined with an unbinned likelihood procedure. By including in the likelihood function a signal term which describes the contribution of many small clusters of signal-like events, this method provides an effective way for looking for weak neutrino flares over different time-scales. The method is sensitive to an overall excess of events distributed over several flares which are not individually detectable. For standard cases (one flare) the discovery potential of the method is worse than a standard time-dependent point source analysis with unknown duration of the flare by a factor depending on the signal-to-background level. However, for flares sufficiently shorter than the total observation period, the method is more sensitive than a time-integrated analysis. (orig.)

  19. A method for untriggered time-dependent searches for multiple flares from neutrino point sources

    Energy Technology Data Exchange (ETDEWEB)

    Gora, D. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Institute of Nuclear Physics PAN, Cracow (Poland); Bernardini, E.; Cruz Silva, A.H. [Institute of Nuclear Physics PAN, Cracow (Poland)

    2011-04-15

    A method for a time-dependent search for flaring astrophysical sources which can be potentially detected by large neutrino experiments is presented. The method uses a time-clustering algorithm combined with an unbinned likelihood procedure. By including in the likelihood function a signal term which describes the contribution of many small clusters of signal-like events, this method provides an effective way for looking for weak neutrino flares over different time-scales. The method is sensitive to an overall excess of events distributed over several flares which are not individually detectable. For standard cases (one flare) the discovery potential of the method is worse than a standard time-dependent point source analysis with unknown duration of the flare by a factor depending on the signal-to-background level. However, for flares sufficiently shorter than the total observation period, the method is more sensitive than a time-integrated analysis. (orig.)

  20. Noise and time delay induce critical point in a bistable system

    Science.gov (United States)

    Zhang, Jianqiang; Nie, Linru; Yu, Lilong; Zhang, Xinyu

    2014-07-01

    We study relaxation time Tc of time-delayed bistable system driven by two cross-correlated Gaussian white noises that one is multiplicative and the other is additive. By means of numerical calculations, the results indicate that: (i) Combination of noise and time delay can induce two critical points about the relaxation time at some certain noise cross-correlation strength λ under the condition that the multiplicative intensity D equals to the additive noise intensity α. (ii) For each fixed D or α, there are two symmetrical critical points which locates in the regions of positive and negative correlations, respectively. Namely, as λ equals to the critical value λc, Tc is independent of the delay time and the result of Tc versus τ is a horizontal line, but as |λ|>|λc| (or |λ|decreases) with the delay time increasing. (iii) In the presence of D = α, the change of λc with D is two symmetrical curves about the axis of λc = 0, and the critical value λc is close to zero for a smaller D, which approaches to +1 or -1 for a greater D.

  1. Two-dimensional Shear Wave Elastography on Conventional Ultrasound Scanners with Time Aligned Sequential Tracking (TAST) and Comb-push Ultrasound Shear Elastography (CUSE)

    Science.gov (United States)

    Song, Pengfei; Macdonald, Michael C.; Behler, Russell H.; Lanning, Justin D.; Wang, Michael H.; Urban, Matthew W.; Manduca, Armando; Zhao, Heng; Callstrom, Matthew R.; Alizad, Azra; Greenleaf, James F.; Chen, Shigao

    2014-01-01

    Two-dimensional (2D) shear wave elastography presents 2D quantitative shear elasticity maps of tissue, which are clinically useful for both focal lesion detection and diffuse disease diagnosis. Realization of 2D shear wave elastography on conventional ultrasound scanners, however, is challenging due to the low tracking pulse-repetition-frequency (PRF) of these systems. While some clinical and research platforms support software beamforming and plane wave imaging with high PRF, the majority of current clinical ultrasound systems do not have the software beamforming capability, which presents a critical challenge for translating the 2D shear wave elastography technique from laboratory to clinical scanners. To address this challenge, this paper presents a Time Aligned Sequential Tracking (TAST) method for shear wave tracking on conventional ultrasound scanners. TAST takes advantage of the parallel beamforming capability of conventional systems and realizes high PRF shear wave tracking by sequentially firing tracking vectors and aligning shear wave data in the temporal direction. The Comb-push Ultrasound Shear Elastography (CUSE) technique was used to simultaneously produce multiple shear wave sources within the field-of-view (FOV) to enhance shear wave signal-to-noise-ratio (SNR) and facilitate robust reconstructions of 2D elasticity maps. TAST and CUSE were realized on a conventional ultrasound scanner (the General Electric LOGIQ E9). A phantom study showed that the shear wave speed measurements from the LOGIQ E9 were in good agreement to the values measured from other 2D shear wave imaging technologies. An inclusion phantom study showed that the LOGIQ E9 had comparable performance to the Aixplorer (Supersonic Imagine) in terms of bias and precision in measuring different sized inclusions. Finally, in vivo case analysis of a breast with a malignant mass, and a liver from a healthy subject demonstrated the feasibility of using the LOGIQ E9 for in vivo 2D shear wave

  2. A sequential logic circuit for coincidences randomly distributed in 'time' and 'duration', with selection and total sampling

    International Nuclear Information System (INIS)

    Carnet, Bernard; Delhumeau, Michel

    1971-06-01

    The principles of binary analysis applied to the investigation of sequential circuits were used to design a two way coincidence circuit whose input may be, random or periodic variables of constant or variable duration. The output signal strictly reproduces the characteristics of the input signal triggering the coincidence. A coincidence between input signals does not produce any output signal if one of the signals has already triggered the output signal. The characteristics of the output signal in relation to those of the input signal are: minimum time jitter, excellent duration reproducibility and maximum efficiency. Some rules are given for achieving these results. The symmetry, transitivity and non-transitivity characteristics of the edges on the primitive graph are analyzed and lead to some rules for positioning the states on a secondary graph. It is from this graph that the equations of the circuits can be calculated. The development of the circuit and its dynamic testing are discussed. For this testing, the functioning of the circuit is simulated by feeding into the input randomly generated signals

  3. PolyWaTT: A polynomial water travel time estimator based on Derivative Dynamic Time Warping and Perceptually Important Points

    Science.gov (United States)

    Claure, Yuri Navarro; Matsubara, Edson Takashi; Padovani, Carlos; Prati, Ronaldo Cristiano

    2018-03-01

    Traditional methods for estimating timing parameters in hydrological science require a rigorous study of the relations of flow resistance, slope, flow regime, watershed size, water velocity, and other local variables. These studies are mostly based on empirical observations, where the timing parameter is estimated using empirically derived formulas. The application of these studies to other locations is not always direct. The locations in which equations are used should have comparable characteristics to the locations from which such equations have been derived. To overcome this barrier, in this work, we developed a data-driven approach to estimate timing parameters such as travel time. Our proposal estimates timing parameters using historical data of the location without the need of adapting or using empirical formulas from other locations. The proposal only uses one variable measured at two different locations on the same river (for instance, two river-level measurements, one upstream and the other downstream on the same river). The recorded data from each location generates two time series. Our method aligns these two time series using derivative dynamic time warping (DDTW) and perceptually important points (PIP). Using data from timing parameters, a polynomial function generalizes the data by inducing a polynomial water travel time estimator, called PolyWaTT. To evaluate the potential of our proposal, we applied PolyWaTT to three different watersheds: a floodplain ecosystem located in the part of Brazil known as Pantanal, the world's largest tropical wetland area; and the Missouri River and the Pearl River, in United States of America. We compared our proposal with empirical formulas and a data-driven state-of-the-art method. The experimental results demonstrate that PolyWaTT showed a lower mean absolute error than all other methods tested in this study, and for longer distances the mean absolute error achieved by PolyWaTT is three times smaller than empirical

  4. Global Stability of Polytopic Linear Time-Varying Dynamic Systems under Time-Varying Point Delays and Impulsive Controls

    Directory of Open Access Journals (Sweden)

    M. de la Sen

    2010-01-01

    Full Text Available This paper investigates the stability properties of a class of dynamic linear systems possessing several linear time-invariant parameterizations (or configurations which conform a linear time-varying polytopic dynamic system with a finite number of time-varying time-differentiable point delays. The parameterizations may be timevarying and with bounded discontinuities and they can be subject to mixed regular plus impulsive controls within a sequence of time instants of zero measure. The polytopic parameterization for the dynamics associated with each delay is specific, so that (q+1 polytopic parameterizations are considered for a system with q delays being also subject to delay-free dynamics. The considered general dynamic system includes, as particular cases, a wide class of switched linear systems whose individual parameterizations are timeinvariant which are governed by a switching rule. However, the dynamic system under consideration is viewed as much more general since it is time-varying with timevarying delays and the bounded discontinuous changes of active parameterizations are generated by impulsive controls in the dynamics and, at the same time, there is not a prescribed set of candidate potential parameterizations.

  5. Heterogeneous dynamics of ionic liquids: A four-point time correlation function approach

    Science.gov (United States)

    Liu, Jiannan; Willcox, Jon A. L.; Kim, Hyung J.

    2018-05-01

    Many ionic liquids show behavior similar to that of glassy systems, e.g., large and long-lasted deviations from Gaussian dynamics and clustering of "mobile" and "immobile" groups of ions. Herein a time-dependent four-point density correlation function—typically used to characterize glassy systems—is implemented for the ionic liquids, choline acetate, and 1-butyl-3-methylimidazolium acetate. Dynamic correlation beyond the first ionic solvation shell on the time scale of nanoseconds is found in the ionic liquids, revealing the cooperative nature of ion motions. The traditional solvent, acetonitrile, on the other hand, shows a much shorter length-scale that decays after a few picoseconds.

  6. The motion of a classical spinning point particle in a Riemann-Cartan space-time

    International Nuclear Information System (INIS)

    Amorim, R.

    1983-01-01

    A consistent set of equations of motion for classical charged point particles with spin and magnetic dipole moment in a Riemann-Cartan space-time is generated from a generalized Lagrangean formalism. The equations avoid the spurius free helicoidal solutions and at the same time conserve the canonical condition of normalization of the 4-velocity. The 4-velocity and the mechanical moment are paralell in this theory, where the condition of orthogonality between the spin and the 4-velocity is treated as a non-holonomic one. (Author) [pt

  7. Real time estimation of photovoltaic modules characteristics and its application to maximum power point operation

    Energy Technology Data Exchange (ETDEWEB)

    Garrigos, Ausias; Blanes, Jose M.; Carrasco, Jose A. [Area de Tecnologia Electronica, Universidad Miguel Hernandez de Elche, Avda. de la Universidad s/n, 03202 Elche, Alicante (Spain); Ejea, Juan B. [Departamento de Ingenieria Electronica, Universidad de Valencia, Avda. Dr Moliner 50, 46100 Valencia, Valencia (Spain)

    2007-05-15

    In this paper, an approximate curve fitting method for photovoltaic modules is presented. The operation is based on solving a simple solar cell electrical model by a microcontroller in real time. Only four voltage and current coordinates are needed to obtain the solar module parameters and set its operation at maximum power in any conditions of illumination and temperature. Despite its simplicity, this method is suitable for low cost real time applications, as control loop reference generator in photovoltaic maximum power point circuits. The theory that supports the estimator together with simulations and experimental results are presented. (author)

  8. Impacts of Satellite Orbit and Clock on Real-Time GPS Point and Relative Positioning.

    Science.gov (United States)

    Shi, Junbo; Wang, Gaojing; Han, Xianquan; Guo, Jiming

    2017-06-12

    Satellite orbit and clock corrections are always treated as known quantities in GPS positioning models. Therefore, any error in the satellite orbit and clock products will probably cause significant consequences for GPS positioning, especially for real-time applications. Currently three types of satellite products have been made available for real-time positioning, including the broadcast ephemeris, the International GNSS Service (IGS) predicted ultra-rapid product, and the real-time product. In this study, these three predicted/real-time satellite orbit and clock products are first evaluated with respect to the post-mission IGS final product, which demonstrates cm to m level orbit accuracies and sub-ns to ns level clock accuracies. Impacts of real-time satellite orbit and clock products on GPS point and relative positioning are then investigated using the P3 and GAMIT software packages, respectively. Numerical results show that the real-time satellite clock corrections affect the point positioning more significantly than the orbit corrections. On the contrary, only the real-time orbit corrections impact the relative positioning. Compared with the positioning solution using the IGS final product with the nominal orbit accuracy of ~2.5 cm, the real-time broadcast ephemeris with ~2 m orbit accuracy provided <2 cm relative positioning error for baselines no longer than 216 km. As for the baselines ranging from 574 to 2982 km, the cm-dm level positioning error was identified for the relative positioning solution using the broadcast ephemeris. The real-time product could result in <5 mm relative positioning accuracy for baselines within 2982 km, slightly better than the predicted ultra-rapid product.

  9. Impacts of Satellite Orbit and Clock on Real-Time GPS Point and Relative Positioning

    Directory of Open Access Journals (Sweden)

    Junbo Shi

    2017-06-01

    Full Text Available Satellite orbit and clock corrections are always treated as known quantities in GPS positioning models. Therefore, any error in the satellite orbit and clock products will probably cause significant consequences for GPS positioning, especially for real-time applications. Currently three types of satellite products have been made available for real-time positioning, including the broadcast ephemeris, the International GNSS Service (IGS predicted ultra-rapid product, and the real-time product. In this study, these three predicted/real-time satellite orbit and clock products are first evaluated with respect to the post-mission IGS final product, which demonstrates cm to m level orbit accuracies and sub-ns to ns level clock accuracies. Impacts of real-time satellite orbit and clock products on GPS point and relative positioning are then investigated using the P3 and GAMIT software packages, respectively. Numerical results show that the real-time satellite clock corrections affect the point positioning more significantly than the orbit corrections. On the contrary, only the real-time orbit corrections impact the relative positioning. Compared with the positioning solution using the IGS final product with the nominal orbit accuracy of ~2.5 cm, the real-time broadcast ephemeris with ~2 m orbit accuracy provided <2 cm relative positioning error for baselines no longer than 216 km. As for the baselines ranging from 574 to 2982 km, the cm–dm level positioning error was identified for the relative positioning solution using the broadcast ephemeris. The real-time product could result in <5 mm relative positioning accuracy for baselines within 2982 km, slightly better than the predicted ultra-rapid product.

  10. Polar coordinated fuzzy controller based real-time maximum-power point control of photovoltaic system

    Energy Technology Data Exchange (ETDEWEB)

    Syafaruddin; Hiyama, Takashi [Department of Computer Science and Electrical Engineering of Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Karatepe, Engin [Department of Electrical and Electronics Engineering of Ege University, 35100 Bornova-Izmir (Turkey)

    2009-12-15

    It is crucial to improve the photovoltaic (PV) system efficiency and to develop the reliability of PV generation control systems. There are two ways to increase the efficiency of PV power generation system. The first is to develop materials offering high conversion efficiency at low cost. The second is to operate PV systems optimally. However, the PV system can be optimally operated only at a specific output voltage and its output power fluctuates under intermittent weather conditions. Moreover, it is very difficult to test the performance of a maximum-power point tracking (MPPT) controller under the same weather condition during the development process and also the field testing is costly and time consuming. This paper presents a novel real-time simulation technique of PV generation system by using dSPACE real-time interface system. The proposed system includes Artificial Neural Network (ANN) and fuzzy logic controller scheme using polar information. This type of fuzzy logic rules is implemented for the first time to operate the PV module at optimum operating point. ANN is utilized to determine the optimum operating voltage for monocrystalline silicon, thin-film cadmium telluride and triple junction amorphous silicon solar cells. The verification of availability and stability of the proposed system through the real-time simulator shows that the proposed system can respond accurately for different scenarios and different solar cell technologies. (author)

  11. Interevent Time Distribution of Renewal Point Process, Case Study: Extreme Rainfall in South Sulawesi

    Science.gov (United States)

    Sunusi, Nurtiti

    2018-03-01

    The study of time distribution of occurrences of extreme rain phenomena plays a very important role in the analysis and weather forecast in an area. The timing of extreme rainfall is difficult to predict because its occurrence is random. This paper aims to determine the inter event time distribution of extreme rain events and minimum waiting time until the occurrence of next extreme event through a point process approach. The phenomenon of extreme rain events over a given period of time is following a renewal process in which the time for events is a random variable τ. The distribution of random variable τ is assumed to be a Pareto, Log Normal, and Gamma. To estimate model parameters, a moment method is used. Consider Rt as the time of the last extreme rain event at one location is the time difference since the last extreme rainfall event. if there are no extreme rain events up to t 0, there will be an opportunity for extreme rainfall events at (t 0, t 0 + δt 0). Furthermore from the three models reviewed, the minimum waiting time until the next extreme rainfall will be determined. The result shows that Log Nrmal model is better than Pareto and Gamma model for predicting the next extreme rainfall in South Sulawesi while the Pareto model can not be used.

  12. A point implicit time integration technique for slow transient flow problems

    Energy Technology Data Exchange (ETDEWEB)

    Kadioglu, Samet Y., E-mail: kadioglu@yildiz.edu.tr [Department of Mathematical Engineering, Yildiz Technical University, 34210 Davutpasa-Esenler, Istanbul (Turkey); Berry, Ray A., E-mail: ray.berry@inl.gov [Idaho National Laboratory, P.O. Box 1625, MS 3840, Idaho Falls, ID 83415 (United States); Martineau, Richard C. [Idaho National Laboratory, P.O. Box 1625, MS 3840, Idaho Falls, ID 83415 (United States)

    2015-05-15

    Highlights: • This new method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods. • It is unconditionally stable, as a fully implicit method would be. • It exhibits the simplicity of implementation of an explicit method. • It is specifically designed for slow transient flow problems of long duration such as can occur inside nuclear reactor coolant systems. • Our findings indicate the new method can integrate slow transient problems very efficiently; and its implementation is very robust. - Abstract: We introduce a point implicit time integration technique for slow transient flow problems. The method treats the solution variables of interest (that can be located at cell centers, cell edges, or cell nodes) implicitly and the rest of the information related to same or other variables are handled explicitly. The method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods, except it involves a few additional function(s) evaluation steps. Moreover, the method is unconditionally stable, as a fully implicit method would be. This new approach exhibits the simplicity of implementation of explicit methods and the stability of implicit methods. It is specifically designed for slow transient flow problems of long duration wherein one would like to perform time integrations with very large time steps. Because the method can be time inaccurate for fast transient problems, particularly with larger time steps, an appropriate solution strategy for a problem that evolves from a fast to a slow transient would be to integrate the fast transient with an explicit or semi-implicit technique and then switch to this point implicit method as soon as the time variation slows sufficiently. We have solved several test problems that result from scalar or systems of flow equations. Our findings indicate the new method can integrate slow transient problems very

  13. A point implicit time integration technique for slow transient flow problems

    International Nuclear Information System (INIS)

    Kadioglu, Samet Y.; Berry, Ray A.; Martineau, Richard C.

    2015-01-01

    Highlights: • This new method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods. • It is unconditionally stable, as a fully implicit method would be. • It exhibits the simplicity of implementation of an explicit method. • It is specifically designed for slow transient flow problems of long duration such as can occur inside nuclear reactor coolant systems. • Our findings indicate the new method can integrate slow transient problems very efficiently; and its implementation is very robust. - Abstract: We introduce a point implicit time integration technique for slow transient flow problems. The method treats the solution variables of interest (that can be located at cell centers, cell edges, or cell nodes) implicitly and the rest of the information related to same or other variables are handled explicitly. The method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods, except it involves a few additional function(s) evaluation steps. Moreover, the method is unconditionally stable, as a fully implicit method would be. This new approach exhibits the simplicity of implementation of explicit methods and the stability of implicit methods. It is specifically designed for slow transient flow problems of long duration wherein one would like to perform time integrations with very large time steps. Because the method can be time inaccurate for fast transient problems, particularly with larger time steps, an appropriate solution strategy for a problem that evolves from a fast to a slow transient would be to integrate the fast transient with an explicit or semi-implicit technique and then switch to this point implicit method as soon as the time variation slows sufficiently. We have solved several test problems that result from scalar or systems of flow equations. Our findings indicate the new method can integrate slow transient problems very

  14. Obliteration dynamics in cerebral arteriovenous malformations after cyberknife radiosurgery: quantification with sequential nidus volumetry and 3-tesla 3-dimensional time-of-flight magnetic resonance angiography.

    Science.gov (United States)

    Wowra, Berndt; Muacevic, Alexander; Tonn, Jörg-Christian; Schoenberg, Stefan O; Reiser, Maximilian; Herrmann, Karin A

    2009-02-01

    To investigate the time-dependent obliteration of cerebral arteriovenous malformations (cAVM) after CyberKnife radiosurgery (CKRS) (Accuray, Inc., Sunnyvale, CA) by means of sequential 3-T, 3-dimensional (3D), time-of-flight (TOF) magnetic resonance angiography (MRA), and volumetry of the arteriovenous malformation (AVM) nidus. In this prospective study, 3D TOF MRA was performed on 20 patients with cAVMs treated by single-fraction CKRS. Three-dimensional TOF MRA was performed on a 3-T, 32-channel magnetic resonance scanner (Magnetom TIM Trio; Siemens Medical Solutions, Erlangen, Germany) with isotropic voxel size at a spatial resolution of 0.6 x 0.6 x 0.6 mm3. The time-dependent relative decay of the transnidal blood flow evidenced by 3D TOF MRA was referred to as "obliteration dynamics." Volumetry of the nidus size was performed with OsiriX imaging software (OsiriX Foundation, Geneva, Switzerland). All patients had 3 to 4 follow-up examinations at 3- to 6-month intervals over a minimum follow-up period of 9 months. Subtotal obliteration was determined if the residual nidus volume was 5% or less of the initial nidus volume. Stata/IC software (Version 10.0; Stata Corp., College Station, TX) was used for statistical analysis and to identify potential factors of AVM obliteration. Regarding their clinical status, case history, and pretreatments, the participants of this study represent difficult-to-treat cAVM patients. The median nidus volume was 1.8 mL (range, 0.4-12.5 mL); the median minimum dose prescribed to the nidus was 22 Gy (range, 16-24 Gy) delivered to the 67% isodose line (range, 55-80%). CKRS was well tolerated, with complications in 2 patients. No further hemorrhages occurred after RS, except 1 small and clinically inapparent incident. The median follow-up period after RS was 25.0 months (range, 11.7-36.8 months). After RS, a statistically significant obliteration was observed in all patients. However, the obliteration dynamics of the cAVMs showed a

  15. GPU-accelerated Modeling and Element-free Reverse-time Migration with Gauss Points Partition

    Science.gov (United States)

    Zhen, Z.; Jia, X.

    2014-12-01

    Element-free method (EFM) has been applied to seismic modeling and migration. Compared with finite element method (FEM) and finite difference method (FDM), it is much cheaper and more flexible because only the information of the nodes and the boundary of the study area are required in computation. In the EFM, the number of Gauss points should be consistent with the number of model nodes; otherwise the accuracy of the intermediate coefficient matrices would be harmed. Thus when we increase the nodes of velocity model in order to obtain higher resolution, we find that the size of the computer's memory will be a bottleneck. The original EFM can deal with at most 81×81 nodes in the case of 2G memory, as tested by Jia and Hu (2006). In order to solve the problem of storage and computation efficiency, we propose a concept of Gauss points partition (GPP), and utilize the GPUs to improve the computation efficiency. Considering the characteristics of the Gaussian points, the GPP method doesn't influence the propagation of seismic wave in the velocity model. To overcome the time-consuming computation of the stiffness matrix (K) and the mass matrix (M), we also use the GPUs in our computation program. We employ the compressed sparse row (CSR) format to compress the intermediate sparse matrices and try to simplify the operations by solving the linear equations with the CULA Sparse's Conjugate Gradient (CG) solver instead of the linear sparse solver 'PARDISO'. It is observed that our strategy can significantly reduce the computational time of K and Mcompared with the algorithm based on CPU. The model tested is Marmousi model. The length of the model is 7425m and the depth is 2990m. We discretize the model with 595x298 nodes, 300x300 Gauss cells and 3x3 Gauss points in each cell. In contrast to the computational time of the conventional EFM, the GPUs-GPP approach can substantially improve the efficiency. The speedup ratio of time consumption of computing K, M is 120 and the

  16. A point-of-care chemistry test for reduction of turnaround and clinical decision time.

    Science.gov (United States)

    Lee, Eui Jung; Shin, Sang Do; Song, Kyoung Jun; Kim, Seong Chun; Cho, Jin Seong; Lee, Seung Chul; Park, Ju Ok; Cha, Won Chul

    2011-06-01

    Our study compared clinical decision time between patients managed with a point-of-care chemistry test (POCT) and patients managed with the traditional central laboratory test (CLT). This was a randomized controlled multicenter trial in the emergency departments (EDs) of 5 academic teaching hospitals. We randomly assigned patients to POCT or CLT stratified by the Emergency Severity Index. A POCT chemistry analyzer (Piccolo; Abaxis, Inc, Union City, Calif), which is able to test liver panel, renal panel, pancreas enzymes, lipid panel, electrolytes, and blood gases, was set up in each ED. Primary and secondary end point was turnaround time and door-to-clinical-decision time. The total 2323 patients were randomly assigned to the POCT group (n = 1167) or to the CLT group (n = 1156). All of the basic characteristics were similar in the 2 groups. The turnaround time (median, interquartile range [IQR]) of the POCT group was shorter than that of the CLT group (14, 12-19 versus 55, 45-69 minutes; P CLT group (46, 33-61 versus 86, 68-107 minutes; P CLT group (P CLT. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Past Negative Time Perspective as a Predictor of Grade Point Average in Occupational Therapy Doctoral Students

    Directory of Open Access Journals (Sweden)

    Pat J. Precin

    2017-05-01

    Full Text Available Time perspective is a fundamental dimension in psychological time, dividing human experiences into past, present, and future. Time perspective influences individuals’ functioning in all occupations, including education. Previous research has examined the relationship between time perspective and academic outcomes, but the same research has not been done, to date, with occupational therapy doctoral students. This quantitative, cross-sectional study investigated the relationship between time perspective and academic success in occupational therapy doctoral students across the United States. Data from the Zimbardo Time Perspective Inventory (ZTPI and grade point averages (GPAs were collected from 50 participants via surveymonkey.com. Past Negative time perspective statistically predicted GPA in the negative direction (p = .001 for students in pre-professional OTD programs, but did not predict GPA for post-professional students. Age, gender, and learning environment did not significantly influence the prediction of GPA in either group. The method and results of this study demonstrate that the ZTPI, an instrument used in the field of psychology, may have value in the profession of occupational therapy and occupational therapy doctoral programs.

  18. Improving Gastric Cancer Outcome Prediction Using Single Time-Point Artificial Neural Network Models

    Science.gov (United States)

    Nilsaz-Dezfouli, Hamid; Abu-Bakar, Mohd Rizam; Arasan, Jayanthi; Adam, Mohd Bakri; Pourhoseingholi, Mohamad Amin

    2017-01-01

    In cancer studies, the prediction of cancer outcome based on a set of prognostic variables has been a long-standing topic of interest. Current statistical methods for survival analysis offer the possibility of modelling cancer survivability but require unrealistic assumptions about the survival time distribution or proportionality of hazard. Therefore, attention must be paid in developing nonlinear models with less restrictive assumptions. Artificial neural network (ANN) models are primarily useful in prediction when nonlinear approaches are required to sift through the plethora of available information. The applications of ANN models for prognostic and diagnostic classification in medicine have attracted a lot of interest. The applications of ANN models in modelling the survival of patients with gastric cancer have been discussed in some studies without completely considering the censored data. This study proposes an ANN model for predicting gastric cancer survivability, considering the censored data. Five separate single time-point ANN models were developed to predict the outcome of patients after 1, 2, 3, 4, and 5 years. The performance of ANN model in predicting the probabilities of death is consistently high for all time points according to the accuracy and the area under the receiver operating characteristic curve. PMID:28469384

  19. Association between time to disease progression end points and overall survival in patients with neuroendocrine tumors

    Directory of Open Access Journals (Sweden)

    Singh S

    2014-08-01

    Full Text Available Simron Singh,1 Xufang Wang,2 Calvin HL Law1 1Sunnybrook Odette Cancer Center, University of Toronto, Toronto, ON, Canada; 2Novartis Oncology, Florham Park, NJ, USA Abstract: Overall survival can be difficult to determine for slowly progressing malignancies, such as neuroendocrine tumors. We investigated whether time to disease progression is positively associated with overall survival in patients with such tumors. A literature review identified 22 clinical trials in patients with neuroendocrine tumors that reported survival probabilities for both time to disease progression (progression-free survival and time to progression and overall survival. Associations between median time to disease progression and median overall survival and between treatment effects on time to disease progression and treatment effects on overall survival were analyzed using weighted least-squares regression. Median time to disease progression was significantly associated with median overall survival (coefficient 0.595; P=0.022. In the seven randomized studies identified, the risk reduction for time to disease progression was positively associated with the risk reduction for overall survival (coefficient on −ln[HR] 0.151; 95% confidence interval −0.843, 1.145; P=0.713. The significant association between median time to disease progression and median overall survival supports the assertion that time to disease progression is an alternative end point to overall survival in patients with neuroendocrine tumors. An apparent albeit not significant trend correlates treatment effects on time to disease progression and treatment effects on overall survival. Informal surveys of physicians’ perceptions are consistent with these concepts, although additional randomized trials are needed. Keywords: neuroendocrine tumors, progression-free survival, disease progression, mortality

  20. A time domain inverse dynamic method for the end point tracking control of a flexible manipulator

    Science.gov (United States)

    Kwon, Dong-Soo; Book, Wayne J.

    1991-01-01

    The inverse dynamic equation of a flexible manipulator was solved in the time domain. By dividing the inverse system equation into the causal part and the anticausal part, we calculated the torque and the trajectories of all state variables for a given end point trajectory. The interpretation of this method in the frequency domain was explained in detail using the two-sided Laplace transform and the convolution integral. The open loop control of the inverse dynamic method shows an excellent result in simulation. For real applications, a practical control strategy is proposed by adding a feedback tracking control loop to the inverse dynamic feedforward control, and its good experimental performance is presented.

  1. Numerical instability of time-discretized one-point kinetic equations

    International Nuclear Information System (INIS)

    Hashimoto, Kengo; Ikeda, Hideaki; Takeda, Toshikazu

    2000-01-01

    The one-point kinetic equations with numerical errors induced by the explicit, implicit and Crank-Nicolson integration methods are derived. The zero-power transfer functions based on the present equations are demonstrated to investigate the numerical stability of the discretized systems. These demonstrations indicate unconditional stability for the implicit and Crank-Nicolson methods but present the possibility of numerical instability for the explicit method. An upper limit of time mesh spacing for the stability is formulated and several numerical calculations are made to confirm the validity of this formula

  2. EBT time-dependent point model code: description and user's guide

    International Nuclear Information System (INIS)

    Roberts, J.F.; Uckan, N.A.

    1977-07-01

    A D-T time-dependent point model has been developed to assess the energy balance in an EBT reactor plasma. Flexibility is retained in the model to permit more recent data to be incorporated as they become available from the theoretical and experimental studies. This report includes the physics models involved, the program logic, and a description of the variables and routines used. All the files necessary for execution are listed, and the code, including a post-execution plotting routine, is discussed

  3. End points for adjuvant therapy trials: has the time come to accept disease-free survival as a surrogate end point for overall survival?

    Science.gov (United States)

    Gill, Sharlene; Sargent, Daniel

    2006-06-01

    The intent of adjuvant therapy is to eradicate micro-metastatic residual disease following curative resection with the goal of preventing or delaying recurrence. The time-honored standard for demonstrating efficacy of new adjuvant therapies is an improvement in overall survival (OS). This typically requires phase III trials of large sample size with lengthy follow-up. With the intent of reducing the cost and time of completing such trials, there is considerable interest in developing alternative or surrogate end points. A surrogate end point may be employed as a substitute to directly assess the effects of an intervention on an already accepted clinical end point such as mortality. When used judiciously, surrogate end points can accelerate the evaluation of new therapies, resulting in the more timely dissemination of effective therapies to patients. The current review provides a perspective on the suitability and validity of disease-free survival (DFS) as an alternative end point for OS. Criteria for establishing surrogacy and the advantages and limitations associated with the use of DFS as a primary end point in adjuvant clinical trials and as the basis for approval of new adjuvant therapies are discussed.

  4. Adaptive sequential controller

    Energy Technology Data Exchange (ETDEWEB)

    El-Sharkawi, Mohamed A. (Renton, WA); Xing, Jian (Seattle, WA); Butler, Nicholas G. (Newberg, OR); Rodriguez, Alonso (Pasadena, CA)

    1994-01-01

    An adaptive sequential controller (50/50') for controlling a circuit breaker (52) or other switching device to substantially eliminate transients on a distribution line caused by closing and opening the circuit breaker. The device adaptively compensates for changes in the response time of the circuit breaker due to aging and environmental effects. A potential transformer (70) provides a reference signal corresponding to the zero crossing of the voltage waveform, and a phase shift comparator circuit (96) compares the reference signal to the time at which any transient was produced when the circuit breaker closed, producing a signal indicative of the adaptive adjustment that should be made. Similarly, in controlling the opening of the circuit breaker, a current transformer (88) provides a reference signal that is compared against the time at which any transient is detected when the circuit breaker last opened. An adaptive adjustment circuit (102) produces a compensation time that is appropriately modified to account for changes in the circuit breaker response, including the effect of ambient conditions and aging. When next opened or closed, the circuit breaker is activated at an appropriately compensated time, so that it closes when the voltage crosses zero and opens when the current crosses zero, minimizing any transients on the distribution line. Phase angle can be used to control the opening of the circuit breaker relative to the reference signal provided by the potential transformer.

  5. Adaptive sequential controller

    Science.gov (United States)

    El-Sharkawi, Mohamed A.; Xing, Jian; Butler, Nicholas G.; Rodriguez, Alonso

    1994-01-01

    An adaptive sequential controller (50/50') for controlling a circuit breaker (52) or other switching device to substantially eliminate transients on a distribution line caused by closing and opening the circuit breaker. The device adaptively compensates for changes in the response time of the circuit breaker due to aging and environmental effects. A potential transformer (70) provides a reference signal corresponding to the zero crossing of the voltage waveform, and a phase shift comparator circuit (96) compares the reference signal to the time at which any transient was produced when the circuit breaker closed, producing a signal indicative of the adaptive adjustment that should be made. Similarly, in controlling the opening of the circuit breaker, a current transformer (88) provides a reference signal that is compared against the time at which any transient is detected when the circuit breaker last opened. An adaptive adjustment circuit (102) produces a compensation time that is appropriately modified to account for changes in the circuit breaker response, including the effect of ambient conditions and aging. When next opened or closed, the circuit breaker is activated at an appropriately compensated time, so that it closes when the voltage crosses zero and opens when the current crosses zero, minimizing any transients on the distribution line. Phase angle can be used to control the opening of the circuit breaker relative to the reference signal provided by the potential transformer.

  6. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.

    2014-12-15

    This paper considers multi-agent sequential hypothesis testing and presents a framework for strategic learning in sequential games with explicit consideration of both temporal and spatial coordination. The associated Bayes risk functions explicitly incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well-defined value functions with respect to (a) the belief states for the case of conditional independent private noisy measurements that are also assumed to be independent identically distributed over time, and (b) the information states for the case of correlated private noisy measurements. A sequential investment game of strategic coordination and delay is also discussed as an application of the proposed strategic learning rules.

  7. Branch Point Withdrawal in Elongational Startup Flow by Time-Resolved Small Angle Neutron Scattering

    KAUST Repository

    Ruocco, N.; Auhl, D.; Bailly, C.; Lindner, P.; Pyckhout-Hintzen, W.; Wischnewski, A.; Leal, L. G.; Hadjichristidis, Nikolaos; Richter, D.

    2016-01-01

    We present a small angle neutron scattering (SANS) investigation of a blend composed of a dendritic polymer and a linear matrix with comparable viscosity in start-up of an elongational flow at Tg + 50. The two-generation dendritic polymer is diluted to 10% by weight in a matrix of a long well-entangled linear chains. Both components consist of mainly 1,4-cis-polyisoprene but differ in isotopic composition. The resulting scattering contrast is sufficiently high to permit time-resolved measurements of the system structure factor during the start-up phase and to follow the retraction processes involving the inner sections of the branched polymer in the nonlinear deformation response. The outer branches and the linear matrix, on the contrary, are in the linear deformation regime. The linear matrix dominates the rheological signature of the blend and the influence of the branched component can barely be detected. However, the neutron scattering intensity is predominantly that of the (branched) minority component so that its dynamics is clearly evident. In the present paper, we use the neutron scattering data to validate the branch point withdrawal process, which could not be unambiguously discerned from rheological measurements in this blend. The maximal tube stretch that the inner branches experience, before the relaxed outer arm material is incorporated into the tube is determined. The in situ scattering experiments demonstrate for the first time the leveling-off of the strain as the result of branch point withdrawal and chain retraction directly on the molecular level. We conclude that branch point motion in the mixture of architecturally complex polymers occurs earlier than would be expected in a purely branched system, presumably due to the different topological environment that the linear matrix presents to the hierarchically deep-buried tube sections. © 2016 American Chemical Society.

  8. Branch Point Withdrawal in Elongational Startup Flow by Time-Resolved Small Angle Neutron Scattering

    KAUST Repository

    Ruocco, N.

    2016-05-27

    We present a small angle neutron scattering (SANS) investigation of a blend composed of a dendritic polymer and a linear matrix with comparable viscosity in start-up of an elongational flow at Tg + 50. The two-generation dendritic polymer is diluted to 10% by weight in a matrix of a long well-entangled linear chains. Both components consist of mainly 1,4-cis-polyisoprene but differ in isotopic composition. The resulting scattering contrast is sufficiently high to permit time-resolved measurements of the system structure factor during the start-up phase and to follow the retraction processes involving the inner sections of the branched polymer in the nonlinear deformation response. The outer branches and the linear matrix, on the contrary, are in the linear deformation regime. The linear matrix dominates the rheological signature of the blend and the influence of the branched component can barely be detected. However, the neutron scattering intensity is predominantly that of the (branched) minority component so that its dynamics is clearly evident. In the present paper, we use the neutron scattering data to validate the branch point withdrawal process, which could not be unambiguously discerned from rheological measurements in this blend. The maximal tube stretch that the inner branches experience, before the relaxed outer arm material is incorporated into the tube is determined. The in situ scattering experiments demonstrate for the first time the leveling-off of the strain as the result of branch point withdrawal and chain retraction directly on the molecular level. We conclude that branch point motion in the mixture of architecturally complex polymers occurs earlier than would be expected in a purely branched system, presumably due to the different topological environment that the linear matrix presents to the hierarchically deep-buried tube sections. © 2016 American Chemical Society.

  9. Value of dual-time-point 18FDG PET-CT imaging on involved-field radiotherapy for hilar and mediastinal metastatic lymph nodes in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Hu Man; Sun Xindong; Liu Ningbo; Gong Heyi; Fu Zheng; Ma Li; Li Xinke; Xu Xiaoqing; Yu Jinming

    2008-01-01

    Objective: To discuss the value of dual-time-point 18 FDG PET-CT imaging on involved-field radiotherapy for hilar and mediastinal metastatic lymph nodes in patients with non-small cell lung cancer (NSCLC). Methods: Fifty-four patients with NSCLC were included in this analysis, including 34 men and 20 women with mean age of 59 (34-76) years. Two sequential PET-CT scans given 3-5 days before surgery were standard single-time-point imaging for the whole body and delayed imaging for the thorax. The pathologic data were used as golden standard to determine the difference between the standard single-time-point and dual-time-point PET-CT imaging in the definition of gross target volume (GTV) of involved-field radiotherapy for metastatic lymph nodes. Results: For hilar metastatic lymph nodes, the GTV defined by single-time-point imaging was consistent with pathologic GTV in 21 patients (39%), comparing with 31 patients (57%) by dual-time-point imaging. Using pathologic data as golden standard, GTV alteration defined by single-time-point imaging had statistically significant difference comparing with that defined by dual-time-point imaging( =519.00, P=0.023). For mediastinal metastatic lymph nodes, the GTV defined by single-time-point imaging was consistent with pathologic GTV in 30 patients (56%), comparing with 36 patients (67%) by dual-time-point imaging. Using pathologic data as golden standard, GTV alteration defined by single-time-point imaging had no statistically significant difference comparing with that defined by dual-time-point imaging (u= 397.50, P=0.616). Conclusions: For patients with NSCLC receiving involved-field radiotherapy, GTV definition for hilar and mediastinal metastatic lymph nodes by dual-time-point imaging is more consistent with that by pathologic data. Dual-time-point imaging has a larger value in terms of target delineation for hilar and mediastinal metastatic lymph nodes. (authors)

  10. Who acts more like a game theorist? Group and indivdual play in a sequential market game and the effect of the time horizon

    NARCIS (Netherlands)

    Müller, W.; Tan, F.

    2013-01-01

    Previous experimental results on one-shot sequential two-player games show that group decisions are closer to the subgame-perfect Nash equilibrium than individual decisions. We extend the analysis of intergroup versus interindividual decision-making by running both one-shot and repeated sessions of

  11. Optimizing the diagnostic power with gastric emptying scintigraphy at multiple time points

    Directory of Open Access Journals (Sweden)

    Gajewski Byron J

    2011-05-01

    Full Text Available Abstract Background Gastric Emptying Scintigraphy (GES at intervals over 4 hours after a standardized radio-labeled meal is commonly regarded as the gold standard for diagnosing gastroparesis. The objectives of this study were: 1 to investigate the best time point and the best combination of multiple time points for diagnosing gastroparesis with repeated GES measures, and 2 to contrast and cross-validate Fisher's Linear Discriminant Analysis (LDA, a rank based Distribution Free (DF approach, and the Classification And Regression Tree (CART model. Methods A total of 320 patients with GES measures at 1, 2, 3, and 4 hour (h after a standard meal using a standardized method were retrospectively collected. Area under the Receiver Operating Characteristic (ROC curve and the rate of false classification through jackknife cross-validation were used for model comparison. Results Due to strong correlation and an abnormality in data distribution, no substantial improvement in diagnostic power was found with the best linear combination by LDA approach even with data transformation. With DF method, the linear combination of 4-h and 3-h increased the Area Under the Curve (AUC and decreased the number of false classifications (0.87; 15.0% over individual time points (0.83, 0.82; 15.6%, 25.3%, for 4-h and 3-h, respectively at a higher sensitivity level (sensitivity = 0.9. The CART model using 4 hourly GES measurements along with patient's age was the most accurate diagnostic tool (AUC = 0.88, false classification = 13.8%. Patients having a 4-h gastric retention value >10% were 5 times more likely to have gastroparesis (179/207 = 86.5% than those with ≤10% (18/113 = 15.9%. Conclusions With a mixed group of patients either referred with suspected gastroparesis or investigated for other reasons, the CART model is more robust than the LDA and DF approaches, capable of accommodating covariate effects and can be generalized for cross institutional applications, but

  12. Double point source W-phase inversion: Real-time implementation and automated model selection

    Science.gov (United States)

    Nealy, Jennifer; Hayes, Gavin

    2015-01-01

    Rapid and accurate characterization of an earthquake source is an extremely important and ever evolving field of research. Within this field, source inversion of the W-phase has recently been shown to be an effective technique, which can be efficiently implemented in real-time. An extension to the W-phase source inversion is presented in which two point sources are derived to better characterize complex earthquakes. A single source inversion followed by a double point source inversion with centroid locations fixed at the single source solution location can be efficiently run as part of earthquake monitoring network operational procedures. In order to determine the most appropriate solution, i.e., whether an earthquake is most appropriately described by a single source or a double source, an Akaike information criterion (AIC) test is performed. Analyses of all earthquakes of magnitude 7.5 and greater occurring since January 2000 were performed with extended analyses of the September 29, 2009 magnitude 8.1 Samoa earthquake and the April 19, 2014 magnitude 7.5 Papua New Guinea earthquake. The AIC test is shown to be able to accurately select the most appropriate model and the selected W-phase inversion is shown to yield reliable solutions that match published analyses of the same events.

  13. Repeated diffusion MRI reveals earliest time point for stratification of radiotherapy response in brain metastases

    DEFF Research Database (Denmark)

    Mahmood, Faisal; Johannesen, Helle H; Geertsen, Poul

    2017-01-01

    An imaging biomarker for early prediction of treatment response potentially provides a non-invasive tool for better prognostics and individualized management of the disease. Radiotherapy (RT) response is generally related to changes in gross tumor volume manifesting months later. In this prospect......An imaging biomarker for early prediction of treatment response potentially provides a non-invasive tool for better prognostics and individualized management of the disease. Radiotherapy (RT) response is generally related to changes in gross tumor volume manifesting months later....... In this prospective study we investigated the apparent diffusion coefficient (ADC), perfusion fraction and pseudo diffusion coefficient derived from diffusion weighted MRI as potential early biomarkers for radiotherapy response of brain metastases. It was a particular aim to assess the optimal time point...

  14. Estimation of main diversification time-points of hantaviruses using phylogenetic analyses of complete genomes.

    Science.gov (United States)

    Castel, Guillaume; Tordo, Noël; Plyusnin, Alexander

    2017-04-02

    Because of the great variability of their reservoir hosts, hantaviruses are excellent models to evaluate the dynamics of virus-host co-evolution. Intriguing questions remain about the timescale of the diversification events that influenced this evolution. In this paper we attempted to estimate the first ever timing of hantavirus diversification based on thirty five available complete genomes representing five major groups of hantaviruses and the assumption of co-speciation of hantaviruses with their respective mammal hosts. Phylogenetic analyses were used to estimate the main diversification points during hantavirus evolution in mammals while host diversification was mostly estimated from independent calibrators taken from fossil records. Our results support an earlier developed hypothesis of co-speciation of known hantaviruses with their respective mammal hosts and hence a common ancestor for all hantaviruses carried by placental mammals. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Undergraduate Consent Form Reading in Relation to Conscientiousness, Procrastination, and the Point-of-Time Effect.

    Science.gov (United States)

    Theiss, Justin D; Hobbs, William B; Giordano, Peter J; Brunson, Olivia M

    2014-07-01

    Informed consent is central to conducting ethical research with human participants. The present study investigated differences in consent form reading in relation to conscientiousness, procrastination, and the point-of-time (PT) effect among undergraduate participants at a U.S. university. As hypothesized, conscientious participants and those who signed up to participate in a research study more days in advance and for earlier sessions (PT effect) read the consent form more thoroughly. However, procrastination was not related to consent form reading. Most importantly, consent form reading in general was poor, with 80% of participants demonstrating that they had not read the consent form. Conscientious participants were more likely to self-report reading the consent form, irrespective of their measured consent form reading. The article closes with suggestions to improve the process of obtaining informed consent with undergraduate participants. © The Author(s) 2014.

  16. Travel Time Estimation Using Freeway Point Detector Data Based on Evolving Fuzzy Neural Inference System.

    Science.gov (United States)

    Tang, Jinjun; Zou, Yajie; Ash, John; Zhang, Shen; Liu, Fang; Wang, Yinhai

    2016-01-01

    Travel time is an important measurement used to evaluate the extent of congestion within road networks. This paper presents a new method to estimate the travel time based on an evolving fuzzy neural inference system. The input variables in the system are traffic flow data (volume, occupancy, and speed) collected from loop detectors located at points both upstream and downstream of a given link, and the output variable is the link travel time. A first order Takagi-Sugeno fuzzy rule set is used to complete the inference. For training the evolving fuzzy neural network (EFNN), two learning processes are proposed: (1) a K-means method is employed to partition input samples into different clusters, and a Gaussian fuzzy membership function is designed for each cluster to measure the membership degree of samples to the cluster centers. As the number of input samples increases, the cluster centers are modified and membership functions are also updated; (2) a weighted recursive least squares estimator is used to optimize the parameters of the linear functions in the Takagi-Sugeno type fuzzy rules. Testing datasets consisting of actual and simulated data are used to test the proposed method. Three common criteria including mean absolute error (MAE), root mean square error (RMSE), and mean absolute relative error (MARE) are utilized to evaluate the estimation performance. Estimation results demonstrate the accuracy and effectiveness of the EFNN method through comparison with existing methods including: multiple linear regression (MLR), instantaneous model (IM), linear model (LM), neural network (NN), and cumulative plots (CP).

  17. Dual time point FDG PET imaging in evaluating pulmonary nodules with low FDG avidity

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua; Song Jianhua; Xing Yan; Wang Taisong; Qiao Wenli

    2010-01-01

    A standardized uptake value (SUV) of 2.5 is frequently used as criteria to evaluate pulmonary lesions. However, false results may occur. Some studies have shown the usefulness of delayed PET for improving accuracy, while others recently have shown fewer promising results. This study was designed to investigate the accuracy of dual time point (DTP) FDG PET imaging in the evaluation of pulmonary lesions with an initial SUV less than 2.5. DTP FDG PET studies were conducted about 1 and 2 hours after FDG injection, and pulmonary lesions with an initial SUV less than 2.5 were identified. Nodules with pathologic results or imaging follow up were included. The differences in SUV and retention index (RI) between benign and malignant pulmonary lesions were analyzed. Receiver operating characteristics (ROC) analysis was performed to evaluate the discriminating validity of SUV and RI. 51 lesions were finally included. A RI greater than 0% was observed in 64% of the benign lesions; 56% had a RI greater than 10%. Among the malignancies, 80.8% had a RI greater than 0%, and 61.5% had a RI greater than 10%. We found no significant differences in SUV and RI between benign and malignant lesions. The area under the ROC curve did not differ from 0.5 whether using SUV or the retention index. Utilizing a SUV increase of 10%, the sensitivity was 61.5%, specificity 44% and accuracy was 52.9%. Dual time point FDG PET may not be of benefit in the evaluation of pulmonary nodules with low FDG avidity. (authors)

  18. Near-real-time regional troposphere models for the GNSS precise point positioning technique

    International Nuclear Information System (INIS)

    Hadas, T; Kaplon, J; Bosy, J; Sierny, J; Wilgan, K

    2013-01-01

    The GNSS precise point positioning (PPP) technique requires high quality product (orbits and clocks) application, since their error directly affects the quality of positioning. For real-time purposes it is possible to utilize ultra-rapid precise orbits and clocks which are disseminated through the Internet. In order to eliminate as many unknown parameters as possible, one may introduce external information on zenith troposphere delay (ZTD). It is desirable that the a priori model is accurate and reliable, especially for real-time application. One of the open problems in GNSS positioning is troposphere delay modelling on the basis of ground meteorological observations. Institute of Geodesy and Geoinformatics of Wroclaw University of Environmental and Life Sciences (IGG WUELS) has developed two independent regional troposphere models for the territory of Poland. The first one is estimated in near-real-time regime using GNSS data from a Polish ground-based augmentation system named ASG-EUPOS established by Polish Head Office of Geodesy and Cartography (GUGiK) in 2008. The second one is based on meteorological parameters (temperature, pressure and humidity) gathered from various meteorological networks operating over the area of Poland and surrounding countries. This paper describes the methodology of both model calculation and verification. It also presents results of applying various ZTD models into kinematic PPP in the post-processing mode using Bernese GPS Software. Positioning results were used to assess the quality of the developed models during changing weather conditions. Finally, the impact of model application to simulated real-time PPP on precision, accuracy and convergence time is discussed. (paper)

  19. Young adult females' views regarding online privacy protection at two time points.

    Science.gov (United States)

    Moreno, Megan A; Kelleher, Erin; Ameenuddin, Nusheen; Rastogi, Sarah

    2014-09-01

    Risks associated with adolescent Internet use include exposure to inappropriate information and privacy violations. Privacy expectations and policies have changed over time. Recent Facebook security setting changes heighten these risks. The purpose of this study was to investigate views and experiences with Internet safety and privacy protection among older adolescent females at two time points, in 2009 and 2012. Two waves of focus groups were conducted, one in 2009 and the other in 2012. During these focus groups, female university students discussed Internet safety risks and strategies and privacy protection. All focus groups were audio recorded and manually transcribed. Qualitative analysis was conducted at the end of each wave and then reviewed and combined in a separate analysis using the constant comparative method. A total of 48 females participated across the two waves. The themes included (1) abundant urban myths, such as the ability for companies to access private information; (2) the importance of filtering one's displayed information; and (3) maintaining age limits on social media access to avoid younger teens' presence on Facebook. The findings present a complex picture of how adolescents view privacy protection and online safety. Older adolescents may be valuable partners in promoting safe and age-appropriate Internet use for younger teens in the changing landscape of privacy. Copyright © 2014. Published by Elsevier Inc.

  20. Terahertz time domain interferometry of a SIS tunnel junction and a quantum point contact

    Energy Technology Data Exchange (ETDEWEB)

    Karadi, Chandu [Univ. of California, Berkeley, CA (United States). Dept. of Physics

    1995-09-01

    The author has applied the Terahertz Time Domain Interferometric (THz-TDI) technique to probe the ultrafast dynamic response of a Superconducting-Insulating-Superconducting (SIS) tunnel junction and a Quantum Point Contact (QPC). The THz-TDI technique involves monitoring changes in the dc current induced by interfering two picosecond electrical pulses on the junction as a function of time delay between them. Measurements of the response of the Nb/AlOxNb SIS tunnel junction from 75--200 GHz are in full agreement with the linear theory for photon-assisted tunneling. Likewise, measurements of the induced current in a QPC as a function of source-drain voltage, gate voltage, frequency, and magnetic field also show strong evidence for photon-assisted transport. These experiments together demonstrate the general applicability of the THz-TDI technique to the characterization of the dynamic response of any micron or nanometer scale device that exhibits a non-linear I-V characteristic.

  1. Gene expression pattern at different time points following ALA-PDT

    International Nuclear Information System (INIS)

    Verwanger, T.; Sanovic, R.; Ruhdorfer, S.; Aberger, F.; Frischauf, A.; Krammer, B.

    2003-01-01

    Full text: The photo sensitizer protoporphyrin IX, endogenously accumulated from the precursor aminolevulinic acid (ALA), is a successful agent in photodynamic tumor therapy. In spite of encouraging clinical results, the basic mechanisms leading to cell death are not fully understood. We therefore set out to analyze the alteration of the gene expression pattern in the squamous cell carcinoma cell line A-431 at different time points after photodynamic treatment with endogenous protoporphyrin IX by cDNA-array technique. Cells were incubated for 16 hours with 100 μg/ml ALA and irradiated with a fluence of 3.5 J/cm 2 resulting in 50 % survival until 8 hours post treatment. RNA was isolated at 1.5, 3, 5 and 8 hours post treatment as well as of 3 controls (untreated, light only and dark), radioactively labelled by reverse transcription with 33P-dCTP and hybridized onto macroarray PCR filters containing PCR products of 2135 genes, which were selected for relevance in tumors, stress response and signal transduction. Verification of observed expression changes was carried out by real time PCR. We found a strong induction of expression of immediate early genes like c-fos as well as decreased expression of genes involved in proliferation like myc and the proliferating cell nuclear antigen (PCNA). (author)

  2. The laboratory information float, time-based competition, and point-of-care testing.

    Science.gov (United States)

    Friedman, B A

    1994-01-01

    A new term, the laboratory information float, should be substituted for turnaround-time when evaluating the performance of the clinical laboratory because it includes the time necessary to make test results both available (ready to use) and accessible (easy to use) to clinicians ordering tests. The laboratory information float can be greatly reduced simply by telescoping the analytic phase of laboratory testing into the preanalytic phase. Significant costs are incurred by such a change, some of which can be reduced by developing a mobile clinical laboratory (sometimes referred to as a "lab-on-a-slab" or "rolling thunder") to transport the analytic devices directly to patient care units. The mobile clinical laboratory should be equipped with an integrated personal computer that can communicate continuously with the host laboratory information system and achieve some semblance of continuous flow processing despite test performance in point-of-care venues. Equipping clinicians with palmtop computers will allow the mobile clinician to access test results and order tests on the run. Such devices can be easily configured to operate in a passive mode, accessing relevant information automatically instead of forcing clinicians to query the laboratory information system periodically for the test results necessary to render care to their patients. The laboratory information float of the year 2,000 will surely be measured in minutes through the judicious deployment of relevant technology such as mobile clinical laboratories and palmtop computers.

  3. Terahertz time domain interferometry of a SIS tunnel junction and a quantum point contact

    International Nuclear Information System (INIS)

    Karadi, C.; Lawrence Berkeley Lab., CA

    1995-09-01

    The author has applied the Terahertz Time Domain Interferometric (THz-TDI) technique to probe the ultrafast dynamic response of a Superconducting-Insulating-Superconducting (SIS) tunnel junction and a Quantum Point Contact (QPC). The THz-TDI technique involves monitoring changes in the dc current induced by interfering two picosecond electrical pulses on the junction as a function of time delay between them. Measurements of the response of the Nb/AlO x /Nb SIS tunnel junction from 75--200 GHz are in full agreement with the linear theory for photon-assisted tunneling. Likewise, measurements of the induced current in a QPC as a function of source-drain voltage, gate voltage, frequency, and magnetic field also show strong evidence for photon-assisted transport. These experiments together demonstrate the general applicability of the THz-TDI technique to the characterization of the dynamic response of any micron or nanometer scale device that exhibits a non-linear I-V characteristic. 133 refs., 49 figs

  4. Time Frame Affects Vantage Point in Episodic and Semantic Autobiographical Memory: Evidence from Response Latencies

    Directory of Open Access Journals (Sweden)

    Jerzy J. Karylowski

    2017-04-01

    Full Text Available Previous research suggests that, with the passage of time, representations of self in episodic memory become less dependent on their initial (internal vantage point and shift toward an external perspective that is normally characteristic of how other people are represented. The present experiment examined this phenomenon in both episodic and semantic autobiographical memory using latency of self-judgments as a measure of accessibility of the internal vs. the external perspective. Results confirmed that in the case of representations of the self retrieved from recent autobiographical memories, trait-judgments regarding unobservable self-aspects (internal perspective were faster than trait judgments regarding observable self-aspects (external perspective. Yet, in the case of self-representations retrieved from memories of a more distant past, judgments regarding observable self-aspects were faster. Those results occurred for both self-representations retrieved from episodic memory and for representations retrieved from the semantic memory. In addition, regardless of the effect of time, greater accessibility of unobservable (vs. observable self-aspects was associated with the episodic rather than semantic autobiographical memory. Those results were modified by neither declared trait’s self-descriptiveness (yes vs. no responses nor by its desirability (highly desirable vs. moderately desirable traits. Implications for compatibility between how self and others are represented and for the role of self in social perception are discussed.

  5. Time Frame Affects Vantage Point in Episodic and Semantic Autobiographical Memory: Evidence from Response Latencies.

    Science.gov (United States)

    Karylowski, Jerzy J; Mrozinski, Blazej

    2017-01-01

    Previous research suggests that, with the passage of time, representations of self in episodic memory become less dependent on their initial (internal) vantage point and shift toward an external perspective that is normally characteristic of how other people are represented. The present experiment examined this phenomenon in both episodic and semantic autobiographical memory using latency of self-judgments as a measure of accessibility of the internal vs. the external perspective. Results confirmed that in the case of representations of the self retrieved from recent autobiographical memories, trait-judgments regarding unobservable self-aspects (internal perspective) were faster than trait judgments regarding observable self-aspects (external perspective). Yet, in the case of self-representations retrieved from memories of a more distant past, judgments regarding observable self-aspects were faster. Those results occurred for both self-representations retrieved from episodic memory and for representations retrieved from the semantic memory. In addition, regardless of the effect of time, greater accessibility of unobservable (vs. observable) self-aspects was associated with the episodic rather than semantic autobiographical memory. Those results were modified by neither declared trait's self-descriptiveness ( yes vs. no responses) nor by its desirability (highly desirable vs. moderately desirable traits). Implications for compatibility between how self and others are represented and for the role of self in social perception are discussed.

  6. Sequential charged particle reaction

    International Nuclear Information System (INIS)

    Hori, Jun-ichi; Ochiai, Kentaro; Sato, Satoshi; Yamauchi, Michinori; Nishitani, Takeo

    2004-01-01

    The effective cross sections for producing the sequential reaction products in F82H, pure vanadium and LiF with respect to the 14.9-MeV neutron were obtained and compared with the estimation ones. Since the sequential reactions depend on the secondary charged particles behavior, the effective cross sections are corresponding to the target nuclei and the material composition. The effective cross sections were also estimated by using the EAF-libraries and compared with the experimental ones. There were large discrepancies between estimated and experimental values. Additionally, we showed the contribution of the sequential reaction on the induced activity and dose rate in the boundary region with water. From the present study, it has been clarified that the sequential reactions are of great importance to evaluate the dose rates around the surface of cooling pipe and the activated corrosion products. (author)

  7. Decreasing Computational Time for VBBinaryLensing by Point Source Approximation

    Science.gov (United States)

    Tirrell, Bethany M.; Visgaitis, Tiffany A.; Bozza, Valerio

    2018-01-01

    The gravitational lens of a binary system produces a magnification map that is more intricate than a single object lens. This map cannot be calculated analytically and one must rely on computational methods to resolve. There are generally two methods of computing the microlensed flux of a source. One is based on ray-shooting maps (Kayser, Refsdal, & Stabell 1986), while the other method is based on an application of Green’s theorem. This second method finds the area of an image by calculating a Riemann integral along the image contour. VBBinaryLensing is a C++ contour integration code developed by Valerio Bozza, which utilizes this method. The parameters at which the source object could be treated as a point source, or in other words, when the source is far enough from the caustic, was of interest to substantially decrease the computational time. The maximum and minimum values of the caustic curves produced, were examined to determine the boundaries for which this simplification could be made. The code was then run for a number of different maps, with separation values and accuracies ranging from 10-1 to 10-3, to test the theoretical model and determine a safe buffer for which minimal error could be made for the approximation. The determined buffer was 1.5+5q, with q being the mass ratio. The theoretical model and the calculated points worked for all combinations of the separation values and different accuracies except the map with accuracy and separation equal to 10-3 for y1 max. An alternative approach has to be found in order to accommodate a wider range of parameters.

  8. Travel Time Estimation Using Freeway Point Detector Data Based on Evolving Fuzzy Neural Inference System.

    Directory of Open Access Journals (Sweden)

    Jinjun Tang

    Full Text Available Travel time is an important measurement used to evaluate the extent of congestion within road networks. This paper presents a new method to estimate the travel time based on an evolving fuzzy neural inference system. The input variables in the system are traffic flow data (volume, occupancy, and speed collected from loop detectors located at points both upstream and downstream of a given link, and the output variable is the link travel time. A first order Takagi-Sugeno fuzzy rule set is used to complete the inference. For training the evolving fuzzy neural network (EFNN, two learning processes are proposed: (1 a K-means method is employed to partition input samples into different clusters, and a Gaussian fuzzy membership function is designed for each cluster to measure the membership degree of samples to the cluster centers. As the number of input samples increases, the cluster centers are modified and membership functions are also updated; (2 a weighted recursive least squares estimator is used to optimize the parameters of the linear functions in the Takagi-Sugeno type fuzzy rules. Testing datasets consisting of actual and simulated data are used to test the proposed method. Three common criteria including mean absolute error (MAE, root mean square error (RMSE, and mean absolute relative error (MARE are utilized to evaluate the estimation performance. Estimation results demonstrate the accuracy and effectiveness of the EFNN method through comparison with existing methods including: multiple linear regression (MLR, instantaneous model (IM, linear model (LM, neural network (NN, and cumulative plots (CP.

  9. Building a Lego wall: Sequential action selection.

    Science.gov (United States)

    Arnold, Amy; Wing, Alan M; Rotshtein, Pia

    2017-05-01

    The present study draws together two distinct lines of enquiry into the selection and control of sequential action: motor sequence production and action selection in everyday tasks. Participants were asked to build 2 different Lego walls. The walls were designed to have hierarchical structures with shared and dissociated colors and spatial components. Participants built 1 wall at a time, under low and high load cognitive states. Selection times for correctly completed trials were measured using 3-dimensional motion tracking. The paradigm enabled precise measurement of the timing of actions, while using real objects to create an end product. The experiment demonstrated that action selection was slowed at decision boundary points, relative to boundaries where no between-wall decision was required. Decision points also affected selection time prior to the actual selection window. Dual-task conditions increased selection errors. Errors mostly occurred at boundaries between chunks and especially when these required decisions. The data support hierarchical control of sequenced behavior. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. A new integrated dual time-point amyloid PET/MRI data analysis method

    Energy Technology Data Exchange (ETDEWEB)

    Cecchin, Diego; Zucchetta, Pietro; Turco, Paolo; Bui, Franco [University Hospital of Padua, Nuclear Medicine Unit, Department of Medicine - DIMED, Padua (Italy); Barthel, Henryk; Tiepolt, Solveig; Sabri, Osama [Leipzig University, Department of Nuclear Medicine, Leipzig (Germany); Poggiali, Davide; Cagnin, Annachiara; Gallo, Paolo [University Hospital of Padua, Neurology, Department of Neurosciences (DNS), Padua (Italy); Frigo, Anna Chiara [University Hospital of Padua, Biostatistics, Epidemiology and Public Health Unit, Department of Cardiac, Thoracic and Vascular Sciences, Padua (Italy)

    2017-11-15

    In the initial evaluation of patients with suspected dementia and Alzheimer's disease, there is no consensus on how to perform semiquantification of amyloid in such a way that it: (1) facilitates visual qualitative interpretation, (2) takes the kinetic behaviour of the tracer into consideration particularly with regard to at least partially correcting for blood flow dependence, (3) analyses the amyloid load based on accurate parcellation of cortical and subcortical areas, (4) includes partial volume effect correction (PVEC), (5) includes MRI-derived topographical indexes, (6) enables application to PET/MRI images and PET/CT images with separately acquired MR images, and (7) allows automation. A method with all of these characteristics was retrospectively tested in 86 subjects who underwent amyloid ({sup 18}F-florbetaben) PET/MRI in a clinical setting (using images acquired 90-110 min after injection, 53 were classified visually as amyloid-negative and 33 as amyloid-positive). Early images after tracer administration were acquired between 0 and 10 min after injection, and later images were acquired between 90 and 110 min after injection. PVEC of the PET data was carried out using the geometric transfer matrix method. Parametric images and some regional output parameters, including two innovative ''dual time-point'' indexes, were obtained. Subjects classified visually as amyloid-positive showed a sparse tracer uptake in the primary sensory, motor and visual areas in accordance with the isocortical stage of the topographic distribution of the amyloid plaque (Braak stages V/VI). In patients classified visually as amyloid-negative, the method revealed detectable levels of tracer uptake in the basal portions of the frontal and temporal lobes, areas that are known to be sites of early deposition of amyloid plaques that probably represented early accumulation (Braak stage A) that is typical of normal ageing. There was a strong correlation between

  11. A new integrated dual time-point amyloid PET/MRI data analysis method

    International Nuclear Information System (INIS)

    Cecchin, Diego; Zucchetta, Pietro; Turco, Paolo; Bui, Franco; Barthel, Henryk; Tiepolt, Solveig; Sabri, Osama; Poggiali, Davide; Cagnin, Annachiara; Gallo, Paolo; Frigo, Anna Chiara

    2017-01-01

    In the initial evaluation of patients with suspected dementia and Alzheimer's disease, there is no consensus on how to perform semiquantification of amyloid in such a way that it: (1) facilitates visual qualitative interpretation, (2) takes the kinetic behaviour of the tracer into consideration particularly with regard to at least partially correcting for blood flow dependence, (3) analyses the amyloid load based on accurate parcellation of cortical and subcortical areas, (4) includes partial volume effect correction (PVEC), (5) includes MRI-derived topographical indexes, (6) enables application to PET/MRI images and PET/CT images with separately acquired MR images, and (7) allows automation. A method with all of these characteristics was retrospectively tested in 86 subjects who underwent amyloid ( 18 F-florbetaben) PET/MRI in a clinical setting (using images acquired 90-110 min after injection, 53 were classified visually as amyloid-negative and 33 as amyloid-positive). Early images after tracer administration were acquired between 0 and 10 min after injection, and later images were acquired between 90 and 110 min after injection. PVEC of the PET data was carried out using the geometric transfer matrix method. Parametric images and some regional output parameters, including two innovative ''dual time-point'' indexes, were obtained. Subjects classified visually as amyloid-positive showed a sparse tracer uptake in the primary sensory, motor and visual areas in accordance with the isocortical stage of the topographic distribution of the amyloid plaque (Braak stages V/VI). In patients classified visually as amyloid-negative, the method revealed detectable levels of tracer uptake in the basal portions of the frontal and temporal lobes, areas that are known to be sites of early deposition of amyloid plaques that probably represented early accumulation (Braak stage A) that is typical of normal ageing. There was a strong correlation between age

  12. Real Time Precise Point Positioning: Preliminary Results for the Brazilian Region

    Science.gov (United States)

    Marques, Haroldo; Monico, João.; Hirokazu Shimabukuro, Milton; Aquino, Marcio

    2010-05-01

    GNSS positioning can be carried out in relative or absolute approach. In the last years, more attention has been driven to the real time precise point positioning (PPP). To achieve centimeter accuracy with this method in real time it is necessary to have available the satellites precise coordinates as well as satellites clocks corrections. The coordinates can be used from the predicted IGU ephemeris, but the satellites clocks must be estimated in a real time. It can be made from a GNSS network as can be seen from EUREF Permanent Network. The infra-structure to realize the PPP in real time is being available in Brazil through the Brazilian Continuous Monitoring Network (RBMC) together with the Sao Paulo State GNSS network which are transmitting GNSS data using NTRIP (Networked Transport of RTCM via Internet Protocol) caster. Based on this information it was proposed a PhD thesis in the Univ. Estadual Paulista (UNESP) aiming to investigate and develop the methodology to estimate the satellites clocks and realize PPP in real time. Then, software is being developed to process GNSS data in the real time PPP mode. A preliminary version of the software was called PPP_RT and is able to process GNSS code and phase data using precise ephemeris and satellites clocks. The PPP processing can be accomplished considering the absolute satellite antenna Phase Center Variation (PCV), Ocean Tide Loading (OTL), Earth Body Tide, among others. The first order ionospheric effects can be eliminated or minimized by ion-free combination or parameterized in the receiver-satellite direction using a stochastic process, e.g. random walk or white noise. In the case of ionosphere estimation, a pseudo-observable is introduced in the mathematical model for each satellite and the initial value can be computed from Klobuchar model or from Global Ionospheric Map (GIM). The adjustment is realized in the recursive mode and the DIA (Detection Identification and Adaptation) is used for quality control. In

  13. Improving multi-GNSS ultra-rapid orbit determination for real-time precise point positioning

    Science.gov (United States)

    Li, Xingxing; Chen, Xinghan; Ge, Maorong; Schuh, Harald

    2018-03-01

    Currently, with the rapid development of multi-constellation Global Navigation Satellite Systems (GNSS), the real-time positioning and navigation are undergoing dramatic changes with potential for a better performance. To provide more precise and reliable ultra-rapid orbits is critical for multi-GNSS real-time positioning, especially for the three merging constellations Beidou, Galileo and QZSS which are still under construction. In this contribution, we present a five-system precise orbit determination (POD) strategy to fully exploit the GPS + GLONASS + BDS + Galileo + QZSS observations from CDDIS + IGN + BKG archives for the realization of hourly five-constellation ultra-rapid orbit update. After adopting the optimized 2-day POD solution (updated every hour), the predicted orbit accuracy can be obviously improved for all the five satellite systems in comparison to the conventional 1-day POD solution (updated every 3 h). The orbit accuracy for the BDS IGSO satellites can be improved by about 80, 45 and 50% in the radial, cross and along directions, respectively, while the corresponding accuracy improvement for the BDS MEO satellites reaches about 50, 20 and 50% in the three directions, respectively. Furthermore, the multi-GNSS real-time precise point positioning (PPP) ambiguity resolution has been performed by using the improved precise satellite orbits. Numerous results indicate that combined GPS + BDS + GLONASS + Galileo (GCRE) kinematic PPP ambiguity resolution (AR) solutions can achieve the shortest time to first fix (TTFF) and highest positioning accuracy in all coordinate components. With the addition of the BDS, GLONASS and Galileo observations to the GPS-only processing, the GCRE PPP AR solution achieves the shortest average TTFF of 11 min with 7{°} cutoff elevation, while the TTFF of GPS-only, GR, GE and GC PPP AR solution is 28, 15, 20 and 17 min, respectively. As the cutoff elevation increases, the reliability and accuracy of GPS-only PPP AR solutions

  14. Studying the potential of point detectors in time-resolved dose verification of dynamic radiotherapy

    International Nuclear Information System (INIS)

    Beierholm, A.R.; Behrens, C.F.; Andersen, C.E.

    2015-01-01

    Modern megavoltage x-ray radiotherapy with high spatial and temporal dose gradients puts high demands on the entire delivery system, including not just the linear accelerator and the multi-leaf collimator, but also algorithms used for optimization and dose calculations, and detectors used for quality assurance and dose verification. In this context, traceable in-phantom dosimetry using a well-characterized point detector is often an important supplement to 2D-based quality assurance methods based on radiochromic film or detector arrays. In this study, an in-house developed dosimetry system based on fiber-coupled plastic scintillator detectors was evaluated and compared with a Farmer-type ionization chamber and a small-volume ionization chamber. An important feature of scintillator detectors is that the sensitive volume of the detector can easily be scaled, and five scintillator detectors of different scintillator length were thus employed to quantify volume averaging effects by direct measurement. The dosimetric evaluation comprised several complex-shape static fields as well as simplified dynamic deliveries using RapidArc, a volumetric-modulated arc therapy modality often used at the participating clinic. The static field experiments showed that the smallest scintillator detectors were in the best agreement with dose calculations, while needing the smallest volume averaging corrections. Concerning total dose measured during RapidArc, all detectors agreed with dose calculations within 1.1 ± 0.7% when positioned in regions of high homogenous dose. Larger differences were observed for high dose gradient and organ at risk locations, were differences between measured and calculated dose were as large as 8.0 ± 5.5%. The smallest differences were generally seen for the small-volume ionization chamber and the smallest scintillators. The time-resolved RapidArc dose profiles revealed volume-dependent discrepancies between scintillator and ionization chamber response

  15. GPU-accelerated element-free reverse-time migration with Gauss points partition

    Science.gov (United States)

    Zhou, Zhen; Jia, Xiaofeng; Qiang, Xiaodong

    2018-06-01

    An element-free method (EFM) has been demonstrated successfully in elasticity, heat conduction and fatigue crack growth problems. We present the theory of EFM and its numerical applications in seismic modelling and reverse time migration (RTM). Compared with the finite difference method and the finite element method, the EFM has unique advantages: (1) independence of grids in computation and (2) lower expense and more flexibility (because only the information of the nodes and the boundary of the concerned area is required). However, in EFM, due to improper computation and storage of some large sparse matrices, such as the mass matrix and the stiffness matrix, the method is difficult to apply to seismic modelling and RTM for a large velocity model. To solve the problem of storage and computation efficiency, we propose a concept of Gauss points partition and utilise the graphics processing unit to improve the computational efficiency. We employ the compressed sparse row format to compress the intermediate large sparse matrices and attempt to simplify the operations by solving the linear equations with CULA solver. To improve the computation efficiency further, we introduce the concept of the lumped mass matrix. Numerical experiments indicate that the proposed method is accurate and more efficient than the regular EFM.

  16. SUVmax by dual time point FDG-PET/CT in recurrent breast cancer

    DEFF Research Database (Denmark)

    Hildebrandt, Malene; Blomberg, Björn; Falch Braas, Kirsten

    ROVER software without partial volume correction. Pearson correlation analysis and Bland-Altman statistics summarized the data. Results The overall mean SUVmax was 8.4 g/mL (SD=3.8) at 1h and 10.9 g/mL (SD=4.7) at 3h. The table displays the Pearson’s r and Bland-Altman statistics. The correlation...... between the two independent observers at 1h and 3h was relatively modest, with r statistics of 0.88 and 0.89, respectively. The intraobserver and intersoftware analyses showed a high correlation, with r statistics of 0.99 to 1.00. Conclusions The interobserver variability was small for both time points......, but slightly greater than the intraobserver and intersoftware variability. This could be explained by a difference in observer selection of FDG avid lesions in patients with multiple lesions. Table Analysis Pearson’s r (95% CI) Bland-Altman plot Mean difference (95% CI) 1h Interobserver 0.88 (0.82 – 0.92) -0...

  17. Analyzing survival curves at a fixed point in time for paired and clustered right-censored data

    Science.gov (United States)

    Su, Pei-Fang; Chi, Yunchan; Lee, Chun-Yi; Shyr, Yu; Liao, Yi-De

    2018-01-01

    In clinical trials, information about certain time points may be of interest in making decisions about treatment effectiveness. Rather than comparing entire survival curves, researchers can focus on the comparison at fixed time points that may have a clinical utility for patients. For two independent samples of right-censored data, Klein et al. (2007) compared survival probabilities at a fixed time point by studying a number of tests based on some transformations of the Kaplan-Meier estimators of the survival function. However, to compare the survival probabilities at a fixed time point for paired right-censored data or clustered right-censored data, their approach would need to be modified. In this paper, we extend the statistics to accommodate the possible within-paired correlation and within-clustered correlation, respectively. We use simulation studies to present comparative results. Finally, we illustrate the implementation of these methods using two real data sets. PMID:29456280

  18. Relationship Between Dual Time Point FDG PET and Immunohistochemical Parameters in Preoperative Colorectal Cancer: Preliminary Study

    International Nuclear Information System (INIS)

    Lee, Jai Hyuen; Lee, Won Ae; Park, Seok Gun; Park, Dong Kook; Namgung, Hwan

    2012-01-01

    The clinical availability of 2 deoxy 2 [18F] fluoro D glucose (FDG) dual time point positron emission tomography/computerized tomography (DTPP) has been investigated in diverse oncologic fields. The aim of this preliminary study was to evaluate the relationship between various immunohistopathologic markers reflecting disease progression of colorectal cancer and parameters extracted from FDG DTPP in colorectal cancer patients. Forty seven patients with histologically confirmed colorectal cancer were analyzed in this preliminary study. FDG DTPP consisted of an early scan 1 h after FDG injection and a delayed scan 1.5 h after the early scan. Based on an analysis of FDG DTPP, we estimated the maximum standardized uptake value (SUV) of tumors on the early and delayed scans (SUV earlya nd SUV delayed, respectively). The retention index (RI) was calculated as follows: (SUV delayed- SUV early) x 100/ SUV early. The clinicopathological findings (size and T and N stages) and immunohistochemical factors [glucose transporter 1 (GLUT 1), hexokinase 2 (HK 2), p53, P504S, and β catenin] were analyzed by visual analysis. The RIs calculated from the SUVs ranged from -1.8 to 73.4 (31.8±15.5). The RIs were significantly higher in patients with high T stages (T3 and T4) than with low T stages (T1 and T2; P earlya nd SUV delayeda nd clinicopathologic parameters in this study. The RIs obtained from preoperative colorectal cancers had a significant relationship to tumor size, T staging, GLUT 1, and p53, in contrast to SUV earlyo r SUV delayed. Compared with previous reports, our results showed that RI can better predict GLUT 1 expression than HK 2 and other immunohistochemical markers. This study demonstrated that the RI might have the potential to be applied as a prognostic marked in preoperative colorectal cancer

  19. Guidelines for time-to-event end-point definitions in trials for pancreatic cancer. Results of the DATECAN initiative (Definition for the Assessment of Time-to-event End-points in CANcer trials).

    Science.gov (United States)

    Bonnetain, Franck; Bonsing, Bert; Conroy, Thierry; Dousseau, Adelaide; Glimelius, Bengt; Haustermans, Karin; Lacaine, François; Van Laethem, Jean Luc; Aparicio, Thomas; Aust, Daniela; Bassi, Claudio; Berger, Virginie; Chamorey, Emmanuel; Chibaudel, Benoist; Dahan, Laeticia; De Gramont, Aimery; Delpero, Jean Robert; Dervenis, Christos; Ducreux, Michel; Gal, Jocelyn; Gerber, Erich; Ghaneh, Paula; Hammel, Pascal; Hendlisz, Alain; Jooste, Valérie; Labianca, Roberto; Latouche, Aurelien; Lutz, Manfred; Macarulla, Teresa; Malka, David; Mauer, Muriel; Mitry, Emmanuel; Neoptolemos, John; Pessaux, Patrick; Sauvanet, Alain; Tabernero, Josep; Taieb, Julien; van Tienhoven, Geertjan; Gourgou-Bourgade, Sophie; Bellera, Carine; Mathoulin-Pélissier, Simone; Collette, Laurence

    2014-11-01

    Using potential surrogate end-points for overall survival (OS) such as Disease-Free- (DFS) or Progression-Free Survival (PFS) is increasingly common in randomised controlled trials (RCTs). However, end-points are too often imprecisely defined which largely contributes to a lack of homogeneity across trials, hampering comparison between them. The aim of the DATECAN (Definition for the Assessment of Time-to-event End-points in CANcer trials)-Pancreas project is to provide guidelines for standardised definition of time-to-event end-points in RCTs for pancreatic cancer. Time-to-event end-points currently used were identified from a literature review of pancreatic RCT trials (2006-2009). Academic research groups were contacted for participation in order to select clinicians and methodologists to participate in the pilot and scoring groups (>30 experts). A consensus was built after 2 rounds of the modified Delphi formal consensus approach with the Rand scoring methodology (range: 1-9). For pancreatic cancer, 14 time to event end-points and 25 distinct event types applied to two settings (detectable disease and/or no detectable disease) were considered relevant and included in the questionnaire sent to 52 selected experts. Thirty experts answered both scoring rounds. A total of 204 events distributed over the 14 end-points were scored. After the first round, consensus was reached for 25 items; after the second consensus was reached for 156 items; and after the face-to-face meeting for 203 items. The formal consensus approach reached the elaboration of guidelines for standardised definitions of time-to-event end-points allowing cross-comparison of RCTs in pancreatic cancer. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. The sequential trauma score - a new instrument for the sequential mortality prediction in major trauma*

    Directory of Open Access Journals (Sweden)

    Huber-Wagner S

    2010-05-01

    score is available at: http://www.sequential-trauma-score.com Conclusions This score is the first sequential, dynamic score to provide a prognosis for patients with blunt major trauma at several points in time. With every additional piece of information the precision increases. The medical team has a simple, useful tool to identify patients at high risk and to predict the prognosis of an individual patient with major trauma very early, quickly and precisely.

  1. The subtyping of primary aldosteronism by adrenal vein sampling: sequential blood sampling causes factitious lateralization.

    Science.gov (United States)

    Rossitto, Giacomo; Battistel, Michele; Barbiero, Giulio; Bisogni, Valeria; Maiolino, Giuseppe; Diego, Miotto; Seccia, Teresa M; Rossi, Gian Paolo

    2018-02-01

    The pulsatile secretion of adrenocortical hormones and a stress reaction occurring when starting adrenal vein sampling (AVS) can affect the selectivity and also the assessment of lateralization when sequential blood sampling is used. We therefore tested the hypothesis that a simulated sequential blood sampling could decrease the diagnostic accuracy of lateralization index for identification of aldosterone-producing adenoma (APA), as compared with bilaterally simultaneous AVS. In 138 consecutive patients who underwent subtyping of primary aldosteronism, we compared the results obtained simultaneously bilaterally when starting AVS (t-15) and 15 min after (t0), with those gained with a simulated sequential right-to-left AVS technique (R ⇒ L) created by combining hormonal values obtained at t-15 and at t0. The concordance between simultaneously obtained values at t-15 and t0, and between simultaneously obtained values and values gained with a sequential R ⇒ L technique, was also assessed. We found a marked interindividual variability of lateralization index values in the patients with bilaterally selective AVS at both time point. However, overall the lateralization index simultaneously determined at t0 provided a more accurate identification of APA than the simulated sequential lateralization indexR ⇒ L (P = 0.001). Moreover, regardless of which side was sampled first, the sequential AVS technique induced a sequence-dependent overestimation of lateralization index. While in APA patients the concordance between simultaneous AVS at t0 and t-15 and between simultaneous t0 and sequential technique was moderate-to-good (K = 0.55 and 0.66, respectively), in non-APA patients, it was poor (K = 0.12 and 0.13, respectively). Sequential AVS generates factitious between-sides gradients, which lower its diagnostic accuracy, likely because of the stress reaction arising upon starting AVS.

  2. Sequential stochastic optimization

    CERN Document Server

    Cairoli, Renzo

    1996-01-01

    Sequential Stochastic Optimization provides mathematicians and applied researchers with a well-developed framework in which stochastic optimization problems can be formulated and solved. Offering much material that is either new or has never before appeared in book form, it lucidly presents a unified theory of optimal stopping and optimal sequential control of stochastic processes. This book has been carefully organized so that little prior knowledge of the subject is assumed; its only prerequisites are a standard graduate course in probability theory and some familiarity with discrete-paramet

  3. Optimisation of beryllium-7 gamma analysis following BCR sequential extraction

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, A. [Plymouth University, School of Geography, Earth and Environmental Sciences, 8 Kirkby Place, Plymouth PL4 8AA (United Kingdom); Blake, W.H., E-mail: wblake@plymouth.ac.uk [Plymouth University, School of Geography, Earth and Environmental Sciences, 8 Kirkby Place, Plymouth PL4 8AA (United Kingdom); Keith-Roach, M.J. [Plymouth University, School of Geography, Earth and Environmental Sciences, 8 Kirkby Place, Plymouth PL4 8AA (United Kingdom); Kemakta Konsult, Stockholm (Sweden)

    2012-03-30

    Graphical abstract: Showing decrease in analytical uncertainty using the optimal (combined preconcentrated sample extract) method. nv (no value) where extract activities were Pointing-Pointer Knowledge of {sup 7}Be geochemical behaviour is required to support tracer studies. Black-Right-Pointing-Pointer Sequential extraction with natural {sup 7}Be returns high analytical uncertainties. Black-Right-Pointing-Pointer Preconcentrating extracts from a large sample mass improved analytical uncertainty. Black-Right-Pointing-Pointer This optimised method can be readily employed in studies using low activity samples. - Abstract: The application of cosmogenic {sup 7}Be as a sediment tracer at the catchment-scale requires an understanding of its geochemical associations in soil to underpin the assumption of irreversible adsorption. Sequential extractions offer a readily accessible means of determining the associations of {sup 7}Be with operationally defined soil phases. However, the subdivision of the low activity concentrations of fallout {sup 7}Be in soils into geochemical fractions can introduce high gamma counting uncertainties. Extending analysis time significantly is not always an option for batches of samples, owing to the on-going decay of {sup 7}Be (t{sub 1/2} = 53.3 days). Here, three different methods of preparing and quantifying {sup 7}Be extracted using the optimised BCR three-step scheme have been evaluated and compared with a focus on reducing analytical uncertainties. The optimal method involved carrying out the BCR extraction in triplicate, sub-sampling each set of triplicates for stable Be analysis before combining each set and coprecipitating the {sup 7}Be with metal oxyhydroxides to produce a thin source for gamma analysis. This method was applied to BCR extractions of natural {sup 7}Be in four agricultural soils. The approach gave good counting statistics from a 24 h analysis period ({approx}10% (2

  4. Campbell and moment measures for finite sequential spatial processes

    NARCIS (Netherlands)

    M.N.M. van Lieshout (Marie-Colette)

    2006-01-01

    textabstractWe define moment and Campbell measures for sequential spatial processes, prove a Campbell-Mecke theorem, and relate the results to their counterparts in the theory of point processes. In particular, we show that any finite sequential spatial process model can be derived as the vector

  5. A robust real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system.

    Science.gov (United States)

    Liu, Wenyang; Cheung, Yam; Sawant, Amit; Ruan, Dan

    2016-05-01

    To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced occlusions. The authors have

  6. A robust real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system

    International Nuclear Information System (INIS)

    Liu, Wenyang; Cheung, Yam; Sawant, Amit; Ruan, Dan

    2016-01-01

    Purpose: To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. Methods: The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. Results: On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced

  7. A robust real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenyang [Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095 (United States); Cheung, Yam [Department of Radiation Oncology, University of Texas Southwestern, Dallas, Texas 75390 (United States); Sawant, Amit [Department of Radiation Oncology, University of Texas Southwestern, Dallas, Texas, 75390 and Department of Radiation Oncology, University of Maryland, College Park, Maryland 20742 (United States); Ruan, Dan, E-mail: druan@mednet.ucla.edu [Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095 and Department of Radiation Oncology, University of California, Los Angeles, Los Angeles, California 90095 (United States)

    2016-05-15

    Purpose: To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. Methods: The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. Results: On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced

  8. New definitions of pointing stability - ac and dc effects. [constant and time-dependent pointing error effects on image sensor performance

    Science.gov (United States)

    Lucke, Robert L.; Sirlin, Samuel W.; San Martin, A. M.

    1992-01-01

    For most imaging sensors, a constant (dc) pointing error is unimportant (unless large), but time-dependent (ac) errors degrade performance by either distorting or smearing the image. When properly quantified, the separation of the root-mean-square effects of random line-of-sight motions into dc and ac components can be used to obtain the minimum necessary line-of-sight stability specifications. The relation between stability requirements and sensor resolution is discussed, with a view to improving communication between the data analyst and the control systems engineer.

  9. Stochastic modelling for biodosimetry: Predicting the chromosomal response to radiation at different time points after exposure

    Science.gov (United States)

    Deperas-Standylo, Joanna; Gudowska-Nowak, Ewa; Ritter, Sylvia

    2014-07-01

    Cytogenetic data accumulated from the experiments with peripheral blood lymphocytes exposed to densely ionizing radiation clearly demonstrate that for particles with linear energy transfer (LET) >100 keV/ μm the derived relative biological effectiveness (RBE) will strongly depend on the time point chosen for the analysis. A reasonable prediction of radiation-induced chromosome damage and its distribution among cells can be achieved by exploiting Monte Carlo methodology along with the information about the radius of the penetrating ion-track and the LET of the ion beam. In order to examine the relationship between the track structure and the distribution of aberrations induced in human lymphocytes and to clarify the correlation between delays in the cell cycle progression and the aberration burden visible at the first post-irradiation mitosis, we have analyzed chromosome aberrations in lymphocytes exposed to Fe-ions with LET values of 335 keV/ μm and formulated a Monte Carlo model which reflects time-delay in mitosis of aberrant cells. Within the model the frequency distributions of aberrations among cells follow the pattern of local energy distribution and are well approximated by a time-dependent compound Poisson statistics. The cell-division cycle of undamaged and aberrant cells and chromosome aberrations are modelled as a renewal process represented by a random sum of (independent and identically distributed) random elements S N = ∑ N i=0 X i . Here N stands for the number of particle traversals of cell nucleus, each leading to a statistically independent formation of X i aberrations. The parameter N is itself a random variable and reflects the cell cycle delay of heavily damaged cells. The probability distribution of S N follows a general law for which the moment generating function satisfies the relation Φ S N = Φ N ( Φ X i ). Formulation of the Monte Carlo model which allows to predict expected fluxes of aberrant and non-aberrant cells has been based

  10. An elevated neutrophil-lymphocyte ratio is associated with adverse outcomes following single time-point paracetamol (acetaminophen) overdose: a time-course analysis.

    Science.gov (United States)

    Craig, Darren G; Kitto, Laura; Zafar, Sara; Reid, Thomas W D J; Martin, Kirsty G; Davidson, Janice S; Hayes, Peter C; Simpson, Kenneth J

    2014-09-01

    The innate immune system is profoundly dysregulated in paracetamol (acetaminophen)-induced liver injury. The neutrophil-lymphocyte ratio (NLR) is a simple bedside index with prognostic value in a number of inflammatory conditions. To evaluate the prognostic accuracy of the NLR in patients with significant liver injury following single time-point and staggered paracetamol overdoses. Time-course analysis of 100 single time-point and 50 staggered paracetamol overdoses admitted to a tertiary liver centre. Timed laboratory samples were correlated with time elapsed after overdose or admission, respectively, and the NLR was calculated. A total of 49/100 single time-point patients developed hepatic encephalopathy (HE). Median NLRs were higher at both 72 (P=0.0047) and 96 h after overdose (P=0.0041) in single time-point patients who died or were transplanted. Maximum NLR values by 96 h were associated with increasing HE grade (P=0.0005). An NLR of more than 16.7 during the first 96 h following overdose was independently associated with the development of HE [odds ratio 5.65 (95% confidence interval 1.67-19.13), P=0.005]. Maximum NLR values by 96 h were strongly associated with the requirement for intracranial pressure monitoring (Pparacetamol overdoses. Future studies should assess the value of incorporating the NLR into existing prognostic and triage indices of single time-point paracetamol overdose.

  11. Short-term memory for spatial, sequential and duration information.

    Science.gov (United States)

    Manohar, Sanjay G; Pertzov, Yoni; Husain, Masud

    2017-10-01

    Space and time appear to play key roles in the way that information is organized in short-term memory (STM). Some argue that they are crucial contexts within which other stored features are embedded, allowing binding of information that belongs together within STM. Here we review recent behavioral, neurophysiological and imaging studies that have sought to investigate the nature of spatial, sequential and duration representations in STM, and how these might break down in disease. Findings from these studies point to an important role of the hippocampus and other medial temporal lobe structures in aspects of STM, challenging conventional accounts of involvement of these regions in only long-term memory.

  12. Real-time UAV trajectory generation using feature points matching between video image sequences

    Science.gov (United States)

    Byun, Younggi; Song, Jeongheon; Han, Dongyeob

    2017-09-01

    Unmanned aerial vehicles (UAVs), equipped with navigation systems and video capability, are currently being deployed for intelligence, reconnaissance and surveillance mission. In this paper, we present a systematic approach for the generation of UAV trajectory using a video image matching system based on SURF (Speeded up Robust Feature) and Preemptive RANSAC (Random Sample Consensus). Video image matching to find matching points is one of the most important steps for the accurate generation of UAV trajectory (sequence of poses in 3D space). We used the SURF algorithm to find the matching points between video image sequences, and removed mismatching by using the Preemptive RANSAC which divides all matching points to outliers and inliers. The inliers are only used to determine the epipolar geometry for estimating the relative pose (rotation and translation) between image sequences. Experimental results from simulated video image sequences showed that our approach has a good potential to be applied to the automatic geo-localization of the UAVs system

  13. Estimating envelope thermal characteristics from single point in time thermal images

    Science.gov (United States)

    Alshatshati, Salahaldin Faraj

    Energy efficiency programs implemented nationally in the U.S. by utilities have rendered savings which have cost on average 0.03/kWh. This cost is still well below generation costs. However, as the lowest cost energy efficiency measures are adopted, this the cost effectiveness of further investment declines. Thus there is a need to more effectively find the most opportunities for savings regionally and nationally, so that the greatest cost effectiveness in implementing energy efficiency can be achieved. Integral to this process. are at scale energy audits. However, on-site building energy audits process are expensive, in the range of US1.29/m2-$5.37/m2 and there are an insufficient number of professionals to perform the audits. Energy audits that can be conducted at-scale and at low cost are needed. Research is presented that addresses at community-wide scales characterization of building envelope thermal characteristics via drive-by and fly-over GPS linked thermal imaging. A central question drives this research: Can single point-in-time thermal images be used to infer U-values and thermal capacitances of walls and roofs? Previous efforts to use thermal images to estimate U-values have been limited to rare steady exterior weather conditions. The approaches posed here are based upon the development two models first is a dynamic model of a building envelope component with unknown U-value and thermal capacitance. The weather conditions prior to the thermal image are used as inputs to the model. The model is solved to determine the exterior surface temperature, ultimately predicted the temperature at the thermal measurement time. The model U-value and thermal capacitance are tuned in order to force the error between the predicted surface temperature and the measured surface temperature from thermal imaging to be near zero. This model is developed simply to show that such a model cannot be relied upon to accurately estimate the U-value. The second is a data

  14. Asynchronous Operators of Sequential Logic Venjunction & Sequention

    CERN Document Server

    Vasyukevich, Vadim

    2011-01-01

    This book is dedicated to new mathematical instruments assigned for logical modeling of the memory of digital devices. The case in point is logic-dynamical operation named venjunction and venjunctive function as well as sequention and sequentional function. Venjunction and sequention operate within the framework of sequential logic. In a form of the corresponding equations, they organically fit analytical expressions of Boolean algebra. Thus, a sort of symbiosis is formed using elements of asynchronous sequential logic on the one hand and combinational logic on the other hand. So, asynchronous

  15. Mining compressing sequential problems

    NARCIS (Netherlands)

    Hoang, T.L.; Mörchen, F.; Fradkin, D.; Calders, T.G.K.

    2012-01-01

    Compression based pattern mining has been successfully applied to many data mining tasks. We propose an approach based on the minimum description length principle to extract sequential patterns that compress a database of sequences well. We show that mining compressing patterns is NP-Hard and

  16. Time-dependent Taylor–Aris dispersion of an initial point concentration

    DEFF Research Database (Denmark)

    Vedel, Søren; Hovad, Emil; Bruus, Henrik

    2014-01-01

    -specific theoretical results, and furthermore predict new phenomena. In particular, for the transient phase before the well-described steady Taylor–Aris limit is reached, we find anomalous diffusion with a dependence of the temporal scaling exponent on the initial release point, generalizing this finding in specific...... cases. During this transient we furthermore identify maxima in the values of the dispersion coefficient which exceed the Taylor–Aris value by amounts that depend on channel geometry, initial point release position, velocity profile and Péclet number. We show that these effects are caused by a difference...

  17. Combinations of Epoch Durations and Cut-Points to Estimate Sedentary Time and Physical Activity among Adolescents

    Science.gov (United States)

    Fröberg, Andreas; Berg, Christina; Larsson, Christel; Boldemann, Cecilia; Raustorp, Anders

    2017-01-01

    The purpose of the current study was to investigate how combinations of different epoch durations and cut-points affect the estimations of sedentary time and physical activity in adolescents. Accelerometer data from 101 adolescents were derived and 30 combinations were used to estimate sedentary time, light, moderate, vigorous, and combined…

  18. DETERMINATION OF THE DELAY DEPARTURE TIME OF THE BUS FROM STOPPING POINT INTO THE CAR FLOW

    Directory of Open Access Journals (Sweden)

    P. Gorbachov

    2014-10-01

    Full Text Available An analytical model for estimation of the bus departure delax from the bus stopping point after passenger loading is presented. The model allows to take into account the traffic density on a particular road section of the transport network, as well as the bus parameters.

  19. Real-time multi-GNSS single-frequency precise point positioning

    NARCIS (Netherlands)

    de Bakker, P.F.; Tiberius, C.C.J.M.

    2017-01-01

    Precise Point Positioning (PPP) is a popular Global Positioning System (GPS) processing strategy, thanks to its high precision without requiring additional GPS infrastructure. Single-Frequency PPP (SF-PPP) takes this one step further by no longer relying on expensive dual-frequency GPS receivers,

  20. The recovery of a time-dependent point source in a linear transport equation: application to surface water pollution

    International Nuclear Information System (INIS)

    Hamdi, Adel

    2009-01-01

    The aim of this paper is to localize the position of a point source and recover the history of its time-dependent intensity function that is both unknown and constitutes the right-hand side of a 1D linear transport equation. Assuming that the source intensity function vanishes before reaching the final control time, we prove that recording the state with respect to the time at two observation points framing the source region leads to the identification of the source position and the recovery of its intensity function in a unique manner. Note that at least one of the two observation points should be strategic. We establish an identification method that determines quasi-explicitly the source position and transforms the task of recovering its intensity function into solving directly a well-conditioned linear system. Some numerical experiments done on a variant of the water pollution BOD model are presented

  1. Point Measurements of Fermi Velocities by a Time-of-Flight Method

    DEFF Research Database (Denmark)

    Falk, David S.; Henningsen, J. O.; Skriver, Hans Lomholt

    1972-01-01

    The present paper describes in detail a new method of obtaining information about the Fermi velocity of electrons in metals, point by point, along certain contours on the Fermi surface. It is based on transmission of microwaves through thin metal slabs in the presence of a static magnetic field...... applied parallel to the surface. The electrons carry the signal across the slab and arrive at the second surface with a phase delay which is measured relative to a reference signal; the velocities are derived by analyzing the magnetic field dependence of the phase delay. For silver we have in this way...... obtained one component of the velocity along half the circumference of the centrally symmetric orbit for B→∥[100]. The results are in agreement with current models for the Fermi surface. For B→∥[011], the electrons involved are not moving in a symmetry plane of the Fermi surface. In such cases one cannot...

  2. Real-time estimation of FLE for point-based registration

    Science.gov (United States)

    Wiles, Andrew D.; Peters, Terry M.

    2009-02-01

    In image-guide surgery, optimizing the accuracy in localizing the surgical tools within the virtual reality environment or 3D image is vitally important, significant effort has been spent reducing the measurement errors at the point of interest or target. This target registration error (TRE) is often defined by a root-mean-square statistic which reduces the vector data to a single term that can be minimized. However, lost in the data reduction is the directionality of the error which, can be modelled using a 3D covariance matrix. Recently, we developed a set of expressions that modeled the TRE statistics for point-based registrations as a function of the fiducial marker geometry, target location and the fiducial localizer error (FLE). Unfortunately, these expressions are only as good as the definition of the FLE. In order to close the gap, we have subsequently developed a closed form expression that estimates the FLE as a function of the estimated fiducial registration error (FRE, the error between the measured fiducials and the best fit locations of those fiducials). The FRE covariance matrix is estimated using a sliding window technique and used as input into the closed form expression to estimate the FLE. The estimated FLE can then used to estimate the TRE which, can be given to the surgeon to permit the procedure to be designed such that the errors associated with the point-based registrations are minimized.

  3. The imaginary-time path integral and non-time-reversal-invariant saddle points of the Euclidean action

    International Nuclear Information System (INIS)

    Dasgupta, I.

    1998-01-01

    We discuss new bounce-like (but non-time-reversal-invariant) solutions to Euclidean equations of motion, which we dub boomerons. In the Euclidean path integral approach to quantum theories, boomerons make an imaginary contribution to the vacuum energy. The fake vacuum instability can be removed by cancelling boomeron contributions against contributions from time reversed boomerons (anti-boomerons). The cancellation rests on a sign choice whose significance is not completely understood in the path integral method. (orig.)

  4. Successful Combination of Sequential Gene Therapy and Rescue Allo-HSCT in Two Children with X-CGD - Importance of Timing.

    Science.gov (United States)

    Siler, Ulrich; Paruzynski, Anna; Holtgreve-Grez, Heidi; Kuzmenko, Elena; Koehl, Ulrike; Renner, Eleonore D; Alhan, Canan; de Loosdrecht, Arjan A van; Schwäble, Joachim; Pfluger, Thomas; Tchinda, Joelle; Schmugge, Markus; Jauch, Anna; Naundorf, Sonja; Kühlcke, Klaus; Notheis, Gundula; Güngor, Tayfun; Kalle, Christof V; Schmidt, Manfred; Grez, Manuel; Seger, Reinhard; Reichenbach, Janine

    2015-01-01

    We report on a series of sequential events leading to long-term survival and cure of pediatric X-linked chronic granulomatous disease (X-CGD) patients after gamma-retroviral gene therapy (GT) and rescue HSCT. Due to therapyrefractory life-threatening infections requiring hematopoietic stem cell transplantation (HSCT) but absence of HLAidentical donors, we treated 2 boys with X-CGD by GT. Following GT both children completely resolved invasive Aspergillus nidulans infections. However, one child developed dual insertional activation of ecotropic viral integration site 1 (EVI1) and signal transducer and activator of transcription 3 (STAT3) genes, leading to myelodysplastic syndrome (MDS) with monosomy 7. Despite resistance to mismatched allo-HSCT with standard myeloablative conditioning, secondary intensified rescue allo-HSCT resulted in 100 % donor chimerism and disappearance of MDS. The other child did not develop MDS despite expansion of a clone with a single insertion in the myelodysplasia syndrome 1 (MDS1) gene and was cured by early standard allo-HSCT. The slowly developing dominance of clones harboring integrations in MDS1-EVI1 may guide clinical intervention strategies, i.e. early rescue allo-HSCT, prior to malignant transformation. GT was essential for both children to survive and to clear therapy-refractory infections, and future GT with safer lentiviral self-inactivated (SIN) vectors may offer a therapeutic alternative for X-CGD patients suffering from life-threatening infections and lacking HLA-identical HSC donors.

  5. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis

    In this thesis we describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon codes with non-uniform profile. With this scheme decoding with good performance...... is possible as low as Eb/No=0.6 dB, which is about 1.7 dB below the signal-to-noise ratio that marks the cut-off rate for the convolutional code. This is possible since the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability...... of computational overflow. Analytical results for the probability that the first Reed-Solomon word is decoded after C computations are presented. This is supported by simulation results that are also extended to other parameters....

  6. Sequential Power-Dependence Theory

    NARCIS (Netherlands)

    Buskens, Vincent; Rijt, Arnout van de

    2008-01-01

    Existing methods for predicting resource divisions in laboratory exchange networks do not take into account the sequential nature of the experimental setting. We extend network exchange theory by considering sequential exchange. We prove that Sequential Power-Dependence Theory—unlike

  7. Modelling sequentially scored item responses

    NARCIS (Netherlands)

    Akkermans, W.

    2000-01-01

    The sequential model can be used to describe the variable resulting from a sequential scoring process. In this paper two more item response models are investigated with respect to their suitability for sequential scoring: the partial credit model and the graded response model. The investigation is

  8. Time Series Discord Detection in Medical Data using a Parallel Relational Database [PowerPoint

    Energy Technology Data Exchange (ETDEWEB)

    Woodbridge, Diane; Wilson, Andrew T.; Rintoul, Mark Daniel; Goldstein, Richard H.

    2015-11-01

    Recent advances in sensor technology have made continuous real-time health monitoring available in both hospital and non-hospital settings. Since data collected from high frequency medical sensors includes a huge amount of data, storing and processing continuous medical data is an emerging big data area. Especially detecting anomaly in real time is important for patients’ emergency detection and prevention. A time series discord indicates a subsequence that has the maximum difference to the rest of the time series subsequences, meaning that it has abnormal or unusual data trends. In this study, we implemented two versions of time series discord detection algorithms on a high performance parallel database management system (DBMS) and applied them to 240 Hz waveform data collected from 9,723 patients. The initial brute force version of the discord detection algorithm takes each possible subsequence and calculates a distance to the nearest non-self match to find the biggest discords in time series. For the heuristic version of the algorithm, a combination of an array and a trie structure was applied to order time series data for enhancing time efficiency. The study results showed efficient data loading, decoding and discord searches in a large amount of data, benefiting from the time series discord detection algorithm and the architectural characteristics of the parallel DBMS including data compression, data pipe-lining, and task scheduling.

  9. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis; Paaske, Erik

    1998-01-01

    We describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon (RS) codes with nonuniform profile. With this scheme decoding with good performance is possible as low...... as Eb/N0=0.6 dB, which is about 1.25 dB below the signal-to-noise ratio (SNR) that marks the cutoff rate for the full system. Accounting for about 0.45 dB due to the outer codes, sequential decoding takes place at about 1.7 dB below the SNR cutoff rate for the convolutional code. This is possible since...... the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability of computational overflow. Analytical results for the probability that the first RS word is decoded after C computations are presented. These results are supported...

  10. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...

  11. A comparison of the real-time and the imaginary-time formalisms of finite temperature field theory for 2,3, and 4-point Green's functions

    International Nuclear Information System (INIS)

    Aurenche, P.; Becherrawy, T.

    1991-07-01

    The predictions of the real-time and the imaginary-time formalisms of Finite Temperature Field Theory is compared. Retarded and advanced amplitudes are constructed in the real-time formalism which are linear combinations of the usual time-ordered thermo-field dynamics amplitudes. These amplitudes can be easily compared to the various analytically continued amplitudes of the imaginary-time formalism. Explicit calculation of the 2,3 and 4-point Green's functions in φ 3 field theory is done in the one and two-loop approximations, and the compatibility of the two formalisms is shown. (author) 17 refs., 12 figs

  12. Developing a Tool Point Control Scheme for a Hydraulic Crane Using Interactive Real-time Dynamic Simulation

    DEFF Research Database (Denmark)

    Pedersen, Mikkel Melters; Hansen, Michael Rygaard; Ballebye, Morten

    2010-01-01

    This paper describes the implementation of an interactive real-time dynamic simulation model of a hydraulic crane. The user input to the model is given continuously via joystick and output is presented continuously in a 3D animation. Using this simulation model, a tool point control scheme...... is developed for the specific crane, considering the saturation phenomena of the system and practical implementation....

  13. The Strengths and the Weakness Points of Mitch Albom's the TIME Keeper

    OpenAIRE

    Widodo, Bobby Chandra Vinanti

    2015-01-01

    Tugas akhir ini membahas tentang novel karya Mitch Albom yang berjudul The Time Keeper. The Time Keeper adalah sebuah novel yang bercerita tentang Dor, manusia pertama yang menghitung waktu di bumi. Ia dihukum di gua karena mencoba mengukur anugrah terbesar dari Tuhan, yaitu Waktu. Lalu kembali ke dunia, dengan membawa jam pasir ajaib dan sebuah misi yaitu menebus kesalahannya dengan mengajarkan makna Waktu pada dua manusia bumi. Dalam tugas akhir ini penulis memberikan ulasan mengenai keleb...

  14. Time dynamics in the point process modeling of seismicity of Aswan area (Egypt)

    International Nuclear Information System (INIS)

    Telesca, Luciano; Mohamed, Abuo El-Ela Amin; ElGabry, Mohamed; El-hady, Sherif; Abou Elenean, Kamal M.

    2012-01-01

    Highlights: ► Time dynamics of shallow Aswan seismic events are time-clusterized. ► Super-Poissonian behavior characterizes shallow and deep events. ► Shallow seismicity shows a cycle at about 402 days. - Abstract: The seismicity observed in the Aswan area (Egypt) between 1986 and 2003 was deeply investigated by means of time-fractal methods. The time dynamics of the aftershock-depleted seismicity, investigated by means of the Allan Factor, reveals that the time-clustering behavior for events occurred at shallow depths (down to 12.5 km from the ground) as well as for events occurred at larger depths (from 15 km down to 27.5 km) does not depend on the ordering of the interevent times but mainly on the shape of the probability density functions of the interevent intervals. Moreover, deep seismicity is more compatible with a Poissonian dynamics than shallow seismicity that is definitely more super-Poissonian. Additionally, the set of shallow events shows a periodicity at about 402 days, which could be consistent with the cyclic loading/unloading operations of the Lake Naser Dam. Such findings contribute to better characterize the seismicity of the Aswan area, which is one of the most interesting water reservoirs in the world, featured by reservoir-induced earthquakes.

  15. Exact analytical solution of time-independent neutron transport equation, and its applications to systems with a point source

    International Nuclear Information System (INIS)

    Mikata, Y.

    2014-01-01

    Highlights: • An exact solution for the one-speed neutron transport equation is obtained. • This solution as well as its derivation are believed to be new. • Neutron flux for a purely absorbing material with a point neutron source off the origin is obtained. • Spherically as well as cylindrically piecewise constant cross sections are studied. • Neutron flux expressions for a point neutron source off the origin are believed to be new. - Abstract: An exact analytical solution of the time-independent monoenergetic neutron transport equation is obtained in this paper. The solution is applied to systems with a point source. Systematic analysis of the solution of the time-independent neutron transport equation, and its applications represent the primary goal of this paper. To the best of the author’s knowledge, certain key results on the scalar neutron flux as well as their derivations are new. As an application of these results, a scalar neutron flux for a purely absorbing medium with a spherically piecewise constant cross section and an isotropic point neutron source off the origin as well as that for a cylindrically piecewise constant cross section with a point neutron source off the origin are obtained. Both of these results are believed to be new

  16. Falling out of time: enhanced memory for scenes presented at behaviorally irrelevant points in time in posttraumatic stress disorder (PTSD).

    Science.gov (United States)

    Levy-Gigi, Einat; Kéri, Szabolcs

    2012-01-01

    Spontaneous encoding of the visual environment depends on the behavioral relevance of the task performed simultaneously. If participants identify target letters or auditory tones while viewing a series of briefly presented natural and urban scenes, they demonstrate effective scene recognition only when a target, but not a behaviorally irrelevant distractor, appears together with the scene. Here, we show that individuals with posttraumatic stress disorder (PTSD), who witnessed the red sludge disaster in Hungary, show the opposite pattern of performance: enhanced recognition of scenes presented together with distractors and deficient recognition of scenes presented with targets. The recognition of trauma-related and neutral scenes was not different in individuals with PTSD. We found a positive correlation between memory for scenes presented with auditory distractors and re-experiencing symptoms (memory intrusions and flashbacks). These results suggest that abnormal encoding of visual scenes at behaviorally irrelevant events might be associated with intrusive experiences by disrupting the flow of time.

  17. Falling out of time: enhanced memory for scenes presented at behaviorally irrelevant points in time in posttraumatic stress disorder (PTSD.

    Directory of Open Access Journals (Sweden)

    Einat Levy-Gigi

    Full Text Available Spontaneous encoding of the visual environment depends on the behavioral relevance of the task performed simultaneously. If participants identify target letters or auditory tones while viewing a series of briefly presented natural and urban scenes, they demonstrate effective scene recognition only when a target, but not a behaviorally irrelevant distractor, appears together with the scene. Here, we show that individuals with posttraumatic stress disorder (PTSD, who witnessed the red sludge disaster in Hungary, show the opposite pattern of performance: enhanced recognition of scenes presented together with distractors and deficient recognition of scenes presented with targets. The recognition of trauma-related and neutral scenes was not different in individuals with PTSD. We found a positive correlation between memory for scenes presented with auditory distractors and re-experiencing symptoms (memory intrusions and flashbacks. These results suggest that abnormal encoding of visual scenes at behaviorally irrelevant events might be associated with intrusive experiences by disrupting the flow of time.

  18. Summary statistics for end-point conditioned continuous-time Markov chains

    DEFF Research Database (Denmark)

    Hobolth, Asger; Jensen, Jens Ledet

    Continuous-time Markov chains are a widely used modelling tool. Applications include DNA sequence evolution, ion channel gating behavior and mathematical finance. We consider the problem of calculating properties of summary statistics (e.g. mean time spent in a state, mean number of jumps between...... two states and the distribution of the total number of jumps) for discretely observed continuous time Markov chains. Three alternative methods for calculating properties of summary statistics are described and the pros and cons of the methods are discussed. The methods are based on (i) an eigenvalue...... decomposition of the rate matrix, (ii) the uniformization method, and (iii) integrals of matrix exponentials. In particular we develop a framework that allows for analyses of rather general summary statistics using the uniformization method....

  19. Free-time and fixed end-point multi-target optimal control theory: Application to quantum computing

    International Nuclear Information System (INIS)

    Mishima, K.; Yamashita, K.

    2011-01-01

    Graphical abstract: The two-state Deutsch-Jozsa algortihm used to demonstrate the utility of free-time and fixed-end point multi-target optimal control theory. Research highlights: → Free-time and fixed-end point multi-target optimal control theory (FRFP-MTOCT) was constructed. → The features of our theory include optimization of the external time-dependent perturbations with high transition probabilities, that of the temporal duration, the monotonic convergence, and the ability to optimize multiple-laser pulses simultaneously. → The advantage of the theory and a comparison with conventional fixed-time and fixed end-point multi-target optimal control theory (FIFP-MTOCT) are presented by comparing data calculated using the present theory with those published previously [K. Mishima, K. Yamashita, Chem. Phys. 361 (2009) 106]. → The qubit system of our interest consists of two polar NaCl molecules coupled by dipole-dipole interaction. → The calculation examples show that our theory is useful for minor adjustment of the external fields. - Abstract: An extension of free-time and fixed end-point optimal control theory (FRFP-OCT) to monotonically convergent free-time and fixed end-point multi-target optimal control theory (FRFP-MTOCT) is presented. The features of our theory include optimization of the external time-dependent perturbations with high transition probabilities, that of the temporal duration, the monotonic convergence, and the ability to optimize multiple-laser pulses simultaneously. The advantage of the theory and a comparison with conventional fixed-time and fixed end-point multi-target optimal control theory (FIFP-MTOCT) are presented by comparing data calculated using the present theory with those published previously [K. Mishima, K. Yamashita, Chem. Phys. 361, (2009), 106]. The qubit system of our interest consists of two polar NaCl molecules coupled by dipole-dipole interaction. The calculation examples show that our theory is useful for minor

  20. Numerical Time Integration Methods for a Point Absorber Wave Energy Converter

    DEFF Research Database (Denmark)

    Zurkinden, Andrew Stephen; Kramer, Morten

    2012-01-01

    on a discretization of the convolution integral. The calculation of the convolution integral is performed at each time step regardless of the chosen numerical scheme. In the second model the convolution integral is replaced by a system of linear ordinary differential equations. The formulation of the state...

  1. Adaptive error detection for HDR/PDR brachytherapy: Guidance for decision making during real-time in vivo point dosimetry

    DEFF Research Database (Denmark)

    Kertzscher Schwencke, Gustavo Adolfo Vladimir; Andersen, Claus E.; Tanderup, Kari

    2014-01-01

    Purpose:This study presents an adaptive error detection algorithm (AEDA) for real-timein vivo point dosimetry during high dose rate (HDR) or pulsed dose rate (PDR) brachytherapy (BT) where the error identification, in contrast to existing approaches, does not depend on an a priori reconstruction ......, and the AEDA’s capacity to distinguish between true and false error scenarios. The study further shows that the AEDA can offer guidance in decision making in the event of potential errors detected with real-time in vivo point dosimetry....... of the dosimeter position reconstruction. Given its nearly exclusive dependence on stable dosimeter positioning, the AEDA allows for a substantially simplified and time efficient real-time in vivo BT dosimetry implementation. Methods:In the event of a measured potential treatment error, the AEDA proposes the most...

  2. Study of time dependence and spectral composition of the signal in circuit of ac electric point motors

    Directory of Open Access Journals (Sweden)

    S. Yu. Buryak

    2014-12-01

    Full Text Available Purpose. The paper is aimed to establish the dependence of changes in the time domain and spectral components of the current in the circuit of the AC electric point motor on its technical condition, to identify the common features for the same type of damage. It is necessary using the analysis of the received signals to carry out the remote diagnosis and determination of faults and defects of electric point motors. In addition it suggested to accelerate the process of the failure, malfunction and damage search. Authors propose the automated approach to the service of remote floor automation equipment, which is located in the envelope of trains. Reduction of the threat to life and health of staff by reducing the residence time in the zone of train movement. Reduce the impact of human factors on the result of service. Methodology. The paper studies the structure, parameters and characteristics, the operation and maintenance characteristics of the AC electric point motors. Determination of the main types of possible faults in the process depending on the operating conditions. Presentation of the electric motor as an object of diagnosis. Findings. The time dependences of the current in the circuit of electric point motor for its various states was obtained. The connection between the technical condition of electric point motor and the performance of current curve in time and spectral domains was established. The revealed deviations from the reference signal were justified. According to the obtained results it was made the conclusion. Originality. A method for diagnosing the state of the AC electric point motor by the time dependence and the spectral composition of the current in its circuit was proposed. The connection diagram to the motor windings based on non-infringement of electric parameters of connection circuit in the actual operating conditions was applied. Practical value. The obtained results suggest the possibility and feasibility of

  3. Convergence Time and Positioning Accuracy Comparison between BDS and GPS Precise Point Positioning

    Directory of Open Access Journals (Sweden)

    ZHANG Xiaohong

    2015-03-01

    Full Text Available BDS/GPS data from MGEX were processed by TriP 2.0 software developed at Wuhan University. Both static and kinematic float PPP are tested by adopting precise satellite orbits and clocks provided by Research Center of GNSS, Wuhan University. The results show that the convergence time of BDS static PPP is about 80min while kinematic PPP is about 100min. For 3h observations, static positioning accuracy of 5 cm and kinematic positioning accuracy of 8 cm in horizontal, about 12 cm in vertical can be achieved. Similar to GPS PPP, precision in east component is worse than north. At present, BDS PPP needs longer convergence time than GPS PPP to reach an absolute positioning accuracy of cm~dm due to the lack of global tracking stations and the limited accuracy of orbit and clock products.

  4. Determining the Points of Change in Time Series of Polarimetric SAR Data

    DEFF Research Database (Denmark)

    Conradsen, Knut; Nielsen, Allan Aasbjerg; Skriver, Henning

    2016-01-01

    We present the likelihood ratio test statistic for the homogeneity of several complex variance–covariance matrices that may be used in order to assess whether at least one change has taken place in a time series of SAR data. Furthermore, we give a factorization of this test statistic into a produ....... The pixelwise analyses are applied on homogeneous subareas covered with different vegetation types using the distribution of the observed p-values....

  5. Space and time in the context of equilibrium-point theory.

    Science.gov (United States)

    Feldman, Anatol G

    2011-05-01

    Advances to the equilibrium-point (EP) theory and solutions to several classical problems of action and perception are suggested and discussed. Among them are (1) the posture-movement problem of how movements away from a stable posture can be made without evoking resistance of posture-stabilizing mechanisms resulting from intrinsic muscle and reflex properties; (2) the problem of kinesthesia or why our sense of limb position is fairly accurate despite ambiguous positional information delivered by proprioceptive and cutaneous signals; (3) the redundancy problems in the control of multiple muscles and degrees of freedom. Central to the EP hypothesis is the notion that there are specific neural structures that represent spatial frames of reference (FRs) selected by the brain in a task-specific way from a set of available FRs. The brain is also able to translate or/and rotate the selected FRs by modifying their major attributes-the origin, metrics, and orientation-and thus substantially influence, in a feed-forward manner, action and perception. The brain does not directly solve redundancy problems: it only limits the amount of redundancy by predetermining where, in spatial coordinates, a task-specific action should emerge and allows all motor elements, including the environment, to interact to deliver a unique action, thus solving the redundancy problem (natural selection of action). The EP theory predicts the existence of specific neurons associated with the control of different attributes of FRs and explains the role of mirror neurons in the inferior frontal gyrus and place cells in the hippocampus. WIREs Cogni Sci 2011 2 287-304 DOI: 10.1002/wcs.108 For further resources related to this article, please visit the WIREs website. Copyright © 2010 John Wiley & Sons, Ltd.

  6. Sequential decay of Reggeons

    International Nuclear Information System (INIS)

    Yoshida, Toshihiro

    1981-01-01

    Probabilities of meson production in the sequential decay of Reggeons, which are formed from the projectile and the target in the hadron-hadron to Reggeon-Reggeon processes, are investigated. It is assumed that pair creation of heavy quarks and simultaneous creation of two antiquark-quark pairs are negligible. The leading-order terms with respect to ratio of creation probabilities of anti s s to anti u u (anti d d) are calculated. The production cross sections in the target fragmentation region are given in terms of probabilities in the initial decay of the Reggeons and an effect of manyparticle production. (author)

  7. Point-splitting in a curved space-time background. 1 -gravitational contribution to the axial anomaly

    International Nuclear Information System (INIS)

    Liggatt, P.A.J.; Macfarlane, A.J.

    1978-01-01

    A prescription is given for point-splitting in a curved space-time background which is a natural generalization of that familiar in quantum electrodynamics and Yang-Mills theory. It is applied (to establish its validity) to the verification of the gravitational anomaly in the divergence of a fermion axial current. Notable features of the prescription are that it defines a point-split current which can be differentiated straightforwardly, and that it involves a natural way of averaging (four dimensionally) over the directions of point splitting. The method can extend directly from the spin-1/2 fermion case treated to other cases, e.g. to spin -3/2 Rarita-Schwinger fermions. (author)

  8. Sequential probability ratio controllers for safeguards radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.L.; Nixon, K.V.

    1984-01-01

    Sequential hypothesis tests applied to nuclear safeguards accounting methods make the methods more sensitive to detecting diversion. The sequential tests also improve transient signal detection in safeguards radiation monitors. This paper describes three microprocessor control units with sequential probability-ratio tests for detecting transient increases in radiation intensity. The control units are designed for three specific applications: low-intensity monitoring with Poisson probability ratios, higher intensity gamma-ray monitoring where fixed counting intervals are shortened by sequential testing, and monitoring moving traffic where the sequential technique responds to variable-duration signals. The fixed-interval controller shortens a customary 50-s monitoring time to an average of 18 s, making the monitoring delay less bothersome. The controller for monitoring moving vehicles benefits from the sequential technique by maintaining more than half its sensitivity when the normal passage speed doubles

  9. Studying the potential of point detectors in time-resolved dose verification of dynamic radiotherapy

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Behrens, C. F.; Andersen, Claus E.

    2015-01-01

    based on fiber-coupled plastic scintillator detectors was evaluated and compared with a Farmer-type ionization chamber and a small-volume ionization chamber. An important feature of scintillator detectors is that the sensitive volume of the detector can easily be scaled, and five scintillator detectors......-volume ionization chamber and the smallest scintillators. The time-resolved RapidArc dose profiles revealed volume-dependent discrepancies between scintillator and ionization chamber response, which confirmed that correction factors for ionization chambers in high temporal and spatial dose gradients are dominated...

  10. [Multiple time scales analysis of spatial differentiation characteristics of non-point source nitrogen loss within watershed].

    Science.gov (United States)

    Liu, Mei-bing; Chen, Xing-wei; Chen, Ying

    2015-07-01

    Identification of the critical source areas of non-point source pollution is an important means to control the non-point source pollution within the watershed. In order to further reveal the impact of multiple time scales on the spatial differentiation characteristics of non-point source nitrogen loss, a SWAT model of Shanmei Reservoir watershed was developed. Based on the simulation of total nitrogen (TN) loss intensity of all 38 subbasins, spatial distribution characteristics of nitrogen loss and critical source areas were analyzed at three time scales of yearly average, monthly average and rainstorms flood process, respectively. Furthermore, multiple linear correlation analysis was conducted to analyze the contribution of natural environment and anthropogenic disturbance on nitrogen loss. The results showed that there were significant spatial differences of TN loss in Shanmei Reservoir watershed at different time scales, and the spatial differentiation degree of nitrogen loss was in the order of monthly average > yearly average > rainstorms flood process. TN loss load mainly came from upland Taoxi subbasin, which was identified as the critical source area. At different time scales, land use types (such as farmland and forest) were always the dominant factor affecting the spatial distribution of nitrogen loss, while the effect of precipitation and runoff on the nitrogen loss was only taken in no fertilization month and several processes of storm flood at no fertilization date. This was mainly due to the significant spatial variation of land use and fertilization, as well as the low spatial variability of precipitation and runoff.

  11. Solving point reactor kinetic equations by time step-size adaptable numerical methods

    International Nuclear Information System (INIS)

    Liao Chaqing

    2007-01-01

    Based on the analysis of effects of time step-size on numerical solutions, this paper showed the necessity of step-size adaptation. Based on the relationship between error and step-size, two-step adaptation methods for solving initial value problems (IVPs) were introduced. They are Two-Step Method and Embedded Runge-Kutta Method. PRKEs were solved by implicit Euler method with step-sizes optimized by using Two-Step Method. It was observed that the control error has important influence on the step-size and the accuracy of solutions. With suitable control errors, the solutions of PRKEs computed by the above mentioned method are accurate reasonably. The accuracy and usage of MATLAB built-in ODE solvers ode23 and ode45, both of which adopt Runge-Kutta-Fehlberg method, were also studied and discussed. (authors)

  12. The two chromosomes of Vibrio cholerae are initiated at different time points in the cell cycle

    DEFF Research Database (Denmark)

    Rasmussen, Tue; Jensen, Rasmus Bugge; Skovgaard, Ole

    2007-01-01

    for analysing flow cytometry data and marker frequency analysis, we show that the small chromosome II is replicated late in the C period of the cell cycle, where most of chromosome I has been replicated. Owing to the delay in initiation of chromosome II, the two chromosomes terminate replication...... at approximately the same time and the average number of replication origins per cell is higher for chromosome I than for chromosome II. Analysis of cell-cycle parameters shows that chromosome replication and segregation is exceptionally fast in V. cholerae. The divided genome and delayed replication of chromosome...... II may reduce the metabolic burden and complexity of chromosome replication by postponing DNA synthesis to the last part of the cell cycle and reducing the need for overlapping replication cycles during rapid proliferation...

  13. Sequential dependencies in magnitude scaling of loudness

    DEFF Research Database (Denmark)

    Joshi, Suyash Narendra; Jesteadt, Walt

    2013-01-01

    Ten normally hearing listeners used a programmable sone-potentiometer knob to adjust the level of a 1000-Hz sinusoid to match the loudness of numbers presented to them in a magnitude production task. Three different power-law exponents (0.15, 0.30, and 0.60) and a log-law with equal steps in d......B were used to program the sone-potentiometer. The knob settings systematically influenced the form of the loudness function. Time series analysis was used to assess the sequential dependencies in the data, which increased with increasing exponent and were greatest for the log-law. It would be possible......, therefore, to choose knob properties that minimized these dependencies. When the sequential dependencies were removed from the data, the slope of the loudness functions did not change, but the variability decreased. Sequential dependencies were only present when the level of the tone on the previous trial...

  14. Experience of Dual Time Point Brain F-18 FDG PET/CT Imaging in Patients with Infections Disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Weung; Kim, Chang Guhn; Park, Soon Ah; Jung, Sang Ah [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2010-06-15

    Dual time point FDG PET imaging (DTPI) has been considered helpful for discrimination of benign and malignant disease, and staging lymph node status in patients with pulmonary malignancy. However, DTPI for benign disease has been rarely reported, and it may show a better description of metabolic status and extent of benign infection disease than early imaging only. The authors report on the use F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) imaging with additional delayed imaging on a 52-year-old man with sparganosis and a 70-year-old man with tuberculous meningitis. To the best of our knowledge, this is the first report on dual time point PET/CT imaging in patients with cerebral sparganosis and tuberculous meningitis.

  15. Effects of point massage of liver and stomach channel combined with pith and trotter soup on postpartum lactation start time.

    Science.gov (United States)

    Luo, Qiong; Hu, Yin; Zhang, Hui

    2017-10-01

    Delay in lactation initiation causes maternal anxiety and subsequent adverse impact on maternal exclusive breast feeding. It is important to explore a safe and convenient way to promote lactation initiation. The feasibility of point massage of liver and stomach channel combined with pith and trotter soup on prevention of delayed lactation initiation was investigated in the present study. 320 women were enrolled and randomly divided into four groups, control group (80 women), point massage group (80 women), pith and trotter soup group (80 women), and massage + soup group (80 women) to compare the lactation initiation time. We found that women in point massage group, pith and trotter soup group and massage + soup group had earlier initiation of lactation compared with control group. Women in massage + soup group had the earliest initiation time of lactation. There were significant differences between massage + soup group and pith and trotter soup group. But, there were no significant differences between massage + soup group and massage group. We conclude that point massage of the liver and stomach channel is easy to operate and has the preventive effect on delayed lactation initiation. Impact statement What is already known on this subject: Initiation of lactation is a critical period in postpartum milk secretion. Delays in lactation initiation lead to maternal anxiety and have an adverse impact on maternal exclusive breastfeeding. Sucking frequently by babies and mammary massage might be effective but insufficient for delayed lactation initiation. What the results of this study add: We found in the present study that lactation initiation is significantly earlier in women receiving routine nursing combined with point massage of liver and stomach channel, or pith trotters soup, or massage of liver and stomach channel with pith and trotters soup than in a control group receiving routine nursing. These three methods are all effective, while the most

  16. A framework for sequential multiblock component methods

    NARCIS (Netherlands)

    Smilde, A.K.; Westerhuis, J.A.; Jong, S.de

    2003-01-01

    Multiblock or multiset methods are starting to be used in chemistry and biology to study complex data sets. In chemometrics, sequential multiblock methods are popular; that is, methods that calculate one component at a time and use deflation for finding the next component. In this paper a framework

  17. Sequential Analysis: Hypothesis Testing and Changepoint Detection

    Science.gov (United States)

    2014-07-11

    maintains the flexibility of deciding sooner than the fixed sample size procedure at the price of some lower power [13, 514]. The sequential probability... markets , detection of signals with unknown arrival time in seismology, navigation, radar and sonar signal processing, speech segmentation, and the... skimming cruise missile can yield a significant increase in the probability of raid annihilation. Furthermore, usually detection systems are

  18. Parity-Time Symmetry and the Toy Models of Gain-Loss Dynamics near the Real Kato's Exceptional Points

    Czech Academy of Sciences Publication Activity Database

    Znojil, Miloslav

    2016-01-01

    Roč. 8, č. 6 (2016), s. 52 ISSN 2073-8994 R&D Projects: GA ČR GA16-22945S Institutional support: RVO:61389005 Keywords : parity-time symmetry * Schrodinger equation * physical Hilbert space * inner-product metric operator * real exceptional points * solvable models * quantum Big Bang * quantum Inflation period Subject RIV: BE - Theoretical Physics Impact factor: 1.457, year: 2016

  19. Real-time resolution of point mutations that cause phenovariance in mice

    Science.gov (United States)

    Wang, Tao; Zhan, Xiaowei; Bu, Chun-Hui; Lyon, Stephen; Pratt, David; Hildebrand, Sara; Choi, Jin Huk; Zhang, Zhao; Zeng, Ming; Wang, Kuan-wen; Turer, Emre; Chen, Zhe; Zhang, Duanwu; Yue, Tao; Wang, Ying; Shi, Hexin; Wang, Jianhui; Sun, Lei; SoRelle, Jeff; McAlpine, William; Hutchins, Noelle; Zhan, Xiaoming; Fina, Maggy; Gobert, Rochelle; Quan, Jiexia; Kreutzer, McKensie; Arnett, Stephanie; Hawkins, Kimberly; Leach, Ashley; Tate, Christopher; Daniel, Chad; Reyna, Carlos; Prince, Lauren; Davis, Sheila; Purrington, Joel; Bearden, Rick; Weatherly, Jennifer; White, Danielle; Russell, Jamie; Sun, Qihua; Tang, Miao; Li, Xiaohong; Scott, Lindsay; Moresco, Eva Marie Y.; McInerney, Gerald M.; Karlsson Hedestam, Gunilla B.; Xie, Yang; Beutler, Bruce

    2015-01-01

    With the wide availability of massively parallel sequencing technologies, genetic mapping has become the rate limiting step in mammalian forward genetics. Here we introduce a method for real-time identification of N-ethyl-N-nitrosourea-induced mutations that cause phenotypes in mice. All mutations are identified by whole exome G1 progenitor sequencing and their zygosity is established in G2/G3 mice before phenotypic assessment. Quantitative and qualitative traits, including lethal effects, in single or multiple combined pedigrees are then analyzed with Linkage Analyzer, a software program that detects significant linkage between individual mutations and aberrant phenotypic scores and presents processed data as Manhattan plots. As multiple alleles of genes are acquired through mutagenesis, pooled “superpedigrees” are created to analyze the effects. Our method is distinguished from conventional forward genetic methods because it permits (1) unbiased declaration of mappable phenotypes, including those that are incompletely penetrant (2), automated identification of causative mutations concurrent with phenotypic screening, without the need to outcross mutant mice to another strain and backcross them, and (3) exclusion of genes not involved in phenotypes of interest. We validated our approach and Linkage Analyzer for the identification of 47 mutations in 45 previously known genes causative for adaptive immune phenotypes; our analysis also implicated 474 genes not previously associated with immune function. The method described here permits forward genetic analysis in mice, limited only by the rates of mutant production and screening. PMID:25605905

  20. Fecal short-chain fatty acids at different time points after ceftriaxone administration in rats

    Directory of Open Access Journals (Sweden)

    Yu. V. Holota

    2017-02-01

    Full Text Available Short-chain fatty acids (SCFAs are major products of the microbial fermentation of dietary fiber in the colon. Recent studies suggest that these products of microbial metabolism in the gut act as signaling molecules, influence host energy homeostasis and play major immunological roles. In the present study, defined the long-term effects of ceftriaxone administration on the fecal SCFAs concentration in Wistar rats. Ceftriaxone (300 mg/kg, i.m. was administered daily for 14 days. Rats were euthanized in 1, 15 and 56 days after ceftriaxone withdrawal. Caecal weight and fecal concentration of SCFAs by gas chromatography were measured. Ceftriaxone administration induced time-dependent rats’ caecal enlargement through accumulation of undigestable substances. In 1 day after ceftriaxone withdrawal, the concentrations of acetic, propionic, butyric acids and total SCFAs were decreased 2.9-, 13.8-, 8.5-, 4.8-fold (P < 0.05, respectively. Concentration of valeric, isovaleric and caproic acids was below the detectable level. That was accompanied by decreased 4.3-fold anaerobic index and increased the relative amount of acetic acid (P < 0.05. In 56 days, concentration of SCFAs was still below control value but higher than in 1 day (except propionic acid. Anaerobic index was lower 1.3-fold (P < 0.05 vs. control. Conclusion: antibiotic therapy induced long-term disturbance in colonic microbiota metabolic activity.

  1. Effect of cryoablation sequential chemotherapy on patients with advanced non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Shu-Hui Yao

    2016-03-01

    Full Text Available Objective: To evaluate the effect of cryoablation sequential chemotherapy on patients with advanced non-small cell lung cancer. Methods: A total of 39 cases with advanced non-small cell lung cancer who received cryoablation sequential chemotherapy and 39 cases with advanced non-small cell lung cancer who received chemotherapy alone were selected and enrolled in sequential group and control group, disease progression and survival of two groups were followed up, and contents of tumor markers and angiogenesis molecules in serum as well as contents of T-lymphocyte subsets in peripheral blood were detected. Results: Progressionfree survival and median overall survival (mOS of sequential group were longer than those of control group, and cumulative cases of tumor progression at various points in time were significantly less than those of control group (P<0.05; 1 month after treatment, serum tumor markers CEA, CYFRA21-1 and NSE contents, serum angiogenesis molecules PCDGF, VEGF and HDGF contents as well as CD3+CD4-CD8+CD28-T cell content in peripheral blood of sequential group were significantly lower than those of control group (P<0.05, and contents of CD3+CD4+CD8-T cell and CD3+CD4-CD8+CD28+T cell in peripheral blood were higher than those of control group (P<0.05. Conclusions: Cryoablation sequential chemotherapy can improve the prognosis of patients with advanced non-small cell lung cancer, delay disease progression, prolong survival time, inhibit angiogenesis and improve immune function.

  2. Stable long-time semiclassical description of zero-point energy in high-dimensional molecular systems.

    Science.gov (United States)

    Garashchuk, Sophya; Rassolov, Vitaly A

    2008-07-14

    Semiclassical implementation of the quantum trajectory formalism [J. Chem. Phys. 120, 1181 (2004)] is further developed to give a stable long-time description of zero-point energy in anharmonic systems of high dimensionality. The method is based on a numerically cheap linearized quantum force approach; stabilizing terms compensating for the linearization errors are added into the time-evolution equations for the classical and nonclassical components of the momentum operator. The wave function normalization and energy are rigorously conserved. Numerical tests are performed for model systems of up to 40 degrees of freedom.

  3. How Feasible is Multiple Time Point Web-Based Data Collection with Individuals Experiencing Street Homelessness?

    Science.gov (United States)

    Eyrich-Garg, Karin M; Moss, Shadiya L

    2017-02-01

    Three barriers investigators often encounter when conducting longitudinal work with homeless or other marginalized populations are difficulty tracking participants, high rates of no-shows for follow-up interviews, and high rates of loss to follow-up. Recent research has shown that homeless populations have substantial access to information technologies, including mobile devices and computers. These technologies have the potential both to make longitudinal data collection with homeless populations easier and to minimize some of these methodological challenges. This pilot study's purpose was to test whether individuals who were homeless and sleeping on the streets-the "street homeless"-would answer questions remotely through a web-based data collection system at regular "follow-up" intervals. We attempted to simulate longitudinal data collection in a condensed time period. Participants (N = 21) completed an in-person baseline interview. Each participant was given a remotely reloadable gift card. Subsequently, weekly for 8 weeks, participants were sent an email with a link to a SurveyMonkey questionnaire. Participants were given 48 h to complete each questionnaire. Data were collected about life on the streets, service use, community inclusion, substance use, and high-risk sexual behaviors. Ten dollars was remotely loaded onto each participant's gift card when they completed the questionnaire within the completion window. A substantial number of participants (67% of the total sample and 86% of the adjusted sample) completed at least seven out of the eight follow-up questionnaires. Most questionnaires were completed at public libraries, but several were completed at other types of locations (social service agencies, places of employment, relative/friend/acquaintance's domiciles, or via mobile phone). Although some of the questions were quite sensitive, very few participants skipped any questions. The only variables associated with questionnaire completion were

  4. Measures and time points relevant for post-surgical follow-up in patients with inflammatory arthritis: a pilot study

    Directory of Open Access Journals (Sweden)

    Tägil Magnus

    2009-05-01

    Full Text Available Abstract Background Rheumatic diseases commonly affect joints and other structures in the hand. Surgery is a traditional way to treat hand problems in inflammatory rheumatic diseases with the purposes of pain relief, restore function and prevent progression. There are numerous measures to choose from, and a combination of outcome measures is recommended. This study evaluated if instruments commonly used in rheumatologic clinical practice are suitable to measure outcome of hand surgery and to identify time points relevant for follow-up. Methods Thirty-one patients (median age 56 years, median disease duration 15 years with inflammatory rheumatic disease and need for post-surgical occupational therapy intervention formed this pilot study group. Hand function was assessed regarding grip strength (Grippit, pain (VAS, range of motion (ROM (Signals of Functional Impairment (SOFI and grip ability (Grip Ability Test (GAT. Activities of daily life (ADL were assessed by means of Disabilities of the Arm, Shoulder and Hand Outcome (DASH and Canadian Occupational Performance Measure (COPM. The instruments were evaluated by responsiveness and feasibility; follow-up points were 0, 3, 6 and 12 months. Results All instruments showed significant change at one or more follow-up points. Satisfaction with activities (COPM showed the best responsiveness (SMR>0.8, while ROM measured with SOFI had low responsiveness at most follow-up time points. The responsiveness of the instruments was stable between 6 and 12 month follow-up which imply that 6 month is an appropriate time for evaluating short-term effect of hand surgery in rheumatic diseases. Conclusion We suggest a core set of instruments measuring pain, grip strength, grip ability, perceived symptoms and self-defined daily activities. This study has shown that VAS pain, the Grippit instrument, GAT, DASH symptom scale and COPM are suitable outcome instruments for hand surgery, while SOFI may be a more insensitive

  5. Retrieval of sea surface velocities using sequential Ocean Colour ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    pended sediment dispersion patterns, in sequential two time lapsed images. .... face advective velocities consists essentially of iden- tifying the ... matrix is time consuming, a significant reduction .... Chauhan, P. 2002 Personal Communication.

  6. Retrieval of sea surface velocities using sequential ocean colour monitor (OCM) data

    Digital Repository Service at National Institute of Oceanography (India)

    Prasad, J.S.; Rajawat, A.S.; Pradhan, Y.; Chauhan, O.S.; Nayak, S.R.

    velocities has been developed. The method is based on matching suspended sediment dispersion patterns, in sequential two time lapsed images. The pattern matching is performed on atmospherically corrected and geo-referenced sequential pair of images by Maximum...

  7. Influence of call broadcast timing within point counts and survey duration on detection probability of marsh breeding birds

    Directory of Open Access Journals (Sweden)

    Douglas C. Tozer

    2017-12-01

    Full Text Available The Standardized North American Marsh Bird Monitoring Protocol recommends point counts consisting of a 5-min passive observation period, meant to be free of broadcast bias, followed by call broadcasts to entice elusive species to reveal their presence. Prior to this protocol, some monitoring programs used point counts with broadcasts during the first 5 min of 10-min counts, and have since used 15-min counts with an initial 5-min passive period (P1 followed by 5 min of broadcasts (B and a second 5-min passive period (P2 to ensure consistency across years and programs. Influence of timing of broadcasts within point counts and point count duration, however, have rarely been assessed. Using data from 23,973 broadcast-assisted 15-min point counts conducted throughout the Great Lakes-St. Lawrence region between 2008 and 2016 by Bird Studies Canada's Marsh Monitoring Program and Central Michigan University's Great Lakes Coastal Wetland Monitoring Program, we estimated detection probabilities of individuals for 14 marsh breeding bird species during P1B compared to BP2, P1 compared to P2, and P1B compared to P1BP2. For six broadcast species and American Bittern (Botaurus lentiginosus, we found no significant difference in detection during P1B compared to BP2, and no significant difference in four of the same seven species during P1 compared to P2. We observed small but significant differences in detection for 7 of 14 species during P1B compared to P1BP2. We conclude that differences in timing of broadcasts causes no bias based on counts from entire 10-minute surveys, although P1B should be favored over BP2 because the same amount of effort in P1B avoids broadcast bias in all broadcast species, and 10-min surveys are superior to 15-min surveys because modest gains in detection of some species does not warrant the additional effort. We recommend point counts consisting of 5 min of passive observation followed by broadcasts, consistent with the standardized

  8. Remotely-sensed, nocturnal, dew point correlates with malaria transmission in Southern Province, Zambia: a time-series study.

    Science.gov (United States)

    Nygren, David; Stoyanov, Cristina; Lewold, Clemens; Månsson, Fredrik; Miller, John; Kamanga, Aniset; Shiff, Clive J

    2014-06-13

    Plasmodium falciparum transmission has decreased significantly in Zambia in the last decade. The malaria transmission is influenced by environmental variables. Incorporation of environmental variables in models of malaria transmission likely improves model fit and predicts probable trends in malaria disease. This work is based on the hypothesis that remotely-sensed environmental factors, including nocturnal dew point, are associated with malaria transmission and sustain foci of transmission during the low transmission season in the Southern Province of Zambia. Thirty-eight rural health centres in Southern Province, Zambia were divided into three zones based on transmission patterns. Correlations between weekly malaria cases and remotely-sensed nocturnal dew point, nocturnal land surface temperature as well as vegetation indices and rainfall were evaluated in time-series analyses from 2012 week 19 to 2013 week 36. Zonal as well as clinic-based, multivariate, autoregressive, integrated, moving average (ARIMAX) models implementing environmental variables were developed to model transmission in 2011 week 19 to 2012 week 18 and forecast transmission in 2013 week 37 to week 41. During the dry, low transmission season significantly higher vegetation indices, nocturnal land surface temperature and nocturnal dew point were associated with the areas of higher transmission. Environmental variables improved ARIMAX models. Dew point and normalized differentiated vegetation index were significant predictors and improved all zonal transmission models. In the high-transmission zone, this was also seen for land surface temperature. Clinic models were improved by adding dew point and land surface temperature as well as normalized differentiated vegetation index. The mean average error of prediction for ARIMAX models ranged from 0.7 to 33.5%. Forecasts of malaria incidence were valid for three out of five rural health centres; however, with poor results at the zonal level. In this

  9. Numerical study and ex vivo assessment of HIFU treatment time reduction through optimization of focal point trajectory

    Science.gov (United States)

    Grisey, A.; Yon, S.; Pechoux, T.; Letort, V.; Lafitte, P.

    2017-03-01

    Treatment time reduction is a key issue to expand the use of high intensity focused ultrasound (HIFU) surgery, especially for benign pathologies. This study aims at quantitatively assessing the potential reduction of the treatment time arising from moving the focal point during long pulses. In this context, the optimization of the focal point trajectory is crucial to achieve a uniform thermal dose repartition and avoid boiling. At first, a numerical optimization algorithm was used to generate efficient trajectories. Thermal conduction was simulated in 3D with a finite difference code and damages to the tissue were modeled using the thermal dose formula. Given an initial trajectory, the thermal dose field was first computed, then, making use of Pontryagin's maximum principle, the trajectory was iteratively refined. Several initial trajectories were tested. Then, an ex vivo study was conducted in order to validate the efficicency of the resulting optimized strategies. Single pulses were performed at 3MHz on fresh veal liver samples with an Echopulse and the size of each unitary lesion was assessed by cutting each sample along three orthogonal planes and measuring the dimension of the whitened area based on photographs. We propose a promising approach to significantly shorten HIFU treatment time: the numerical optimization algorithm was shown to provide a reliable insight on trajectories that can improve treatment strategies. The model must now be improved in order to take in vivo conditions into account and extensively validated.

  10. Economic Order Quality Model for Determining the Sales Prices of Fresh Goods at Various Points in Time

    Directory of Open Access Journals (Sweden)

    Po-Yu Chen

    2017-01-01

    Full Text Available Although the safe consumption of goods such as food products, medicine, and vaccines is related to their freshness, consumers frequently understand less than suppliers about the freshness of goods when they purchase them. Because of this lack of information, apart from sales prices, consumers refer only to the manufacturing and expiration dates when deciding whether to purchase and how many of these goods to buy. If dealers could determine the sales price at each point in time and customers’ intention to buy goods of varying freshness, then dealers could set an optimal inventory cycle and allocate a weekly sales price for each point in time, thereby maximizing the profit per unit time. Therefore, in this study, an economic order quality model was established to enable discussion of the optimal control of sales prices. The technique for identifying the optimal solution for the model was determined, the characteristics of the optimal solution were demonstrated, and the implications of the solution’s sensitivity analysis were explained.

  11. Documentscape: Intertextuality, Sequentiality & Autonomy at Work

    DEFF Research Database (Denmark)

    Christensen, Lars Rune; Bjørn, Pernille

    2014-01-01

    On the basis of an ethnographic field study, this article introduces the concept of documentscape to the analysis of document-centric work practices. The concept of documentscape refers to the entire ensemble of documents in their mutual intertextual interlocking. Providing empirical data from...... a global software development case, we show how hierarchical structures and sequentiality across the interlocked documents are critical to how actors make sense of the work of others and what to do next in a geographically distributed setting. Furthermore, we found that while each document is created...... as part of a quasi-sequential order, this characteristic does not make the document, as a single entity, into a stable object. Instead, we found that the documents were malleable and dynamic while suspended in intertextual structures. Our concept of documentscape points to how the hierarchical structure...

  12. Geospatial exposure to point-of-sale tobacco: real-time craving and smoking-cessation outcomes.

    Science.gov (United States)

    Kirchner, Thomas R; Cantrell, Jennifer; Anesetti-Rothermel, Andrew; Ganz, Ollie; Vallone, Donna M; Abrams, David B

    2013-10-01

    Little is known about the factors that drive the association between point-of-sale marketing and behavior, because methods that directly link individual-level use outcomes to real-world point-of-sale exposure are only now beginning to be developed. Daily outcomes during smoking cessation were examined as a function of both real-time geospatial exposure to point-of-sale tobacco (POST) and subjective craving to smoke. Continuous individual geospatial location data collected over the first month of a smoking-cessation attempt in 2010-2012 (N=475) were overlaid on a POST outlet geodatabase (N=1060). Participants' mobility data were used to quantify the number of times they came into contact with a POST outlet. Participants recorded real-time craving levels and smoking status via ecological momentary assessment (EMA) on cellular telephones. The final data set spanned a total of 12,871 days of EMA and geospatial tracking. Lapsing was significantly more likely on days with any POST contact (OR=1.19, 95% CI=1.18, 1.20), and increasingly likely as the number of daily POST contacts increased (OR=1.07, 95% CI=1.06, 1.08). Overall, daily POST exposure was significantly associated with lapsing when craving was low (OR=1.22, 95% CI=1.20, 1.23); high levels of craving were more directly associated with lapse outcomes. These data shed light on the way mobility patterns drive a dynamic interaction between individuals and the POST environment, demonstrating that quantification of individuals' exposure to POST marketing can be used to identify previously unrecognized patterns of association among individual mobility, the built environment, and behavioral outcomes. © 2013 American Journal of Preventive Medicine.

  13. The value of dual time point 18F-FDG PET imaging for the differentiation between malignant and benign lesions

    International Nuclear Information System (INIS)

    Lan, X.-L.; Zhang, Y.-X.; Wu, Z.-J.; Jia, Q.; Wei, H.; Gao, Z.-R.

    2008-01-01

    Aim: To assess the clinical value of dual time point 2-[ 18 F]-fluoro-2-deoxy-D-glucose positron emission tomography ( 18 F-FDG PET) imaging for the differentiation between malignant and benign lesions. Materials and methods: Ninety-six patients (28 patients with primary lung cancer, 18 patients with digestive system carcinoma, 13 patients with other malignant tumours, and 37 patients with benign lesions) underwent FDG-PET/CT at two time points: examination 1 at 45-55 min and examination 2 at 160 ± 24 (150-180) min after the intravenous injection of 233 ± 52 (185-370) MBq 18 F-FDG. Reconstructed images were evaluated qualitatively and quantitatively. The maximum standardized uptake values (SUVmax) of the lesions were calculated for both time points. An increase was considered to have occurred if the SUVs at examination 2 had increased by >10% as compared with those at the examination 1. Results: The lesions in 24 of 28 (86%) patients with primary lung cancer had an SUVmax ≥2.5 at examination 1. Of these, SUVmax values increased in 23 patients, but had not changed in one patient, at examination 2. The lesions in the other four patients with primary lung tumour had SUVmax values between 1.5 and 2.5 at examination 1, which were considered as suspected positive, increased SUVmax values were observed in three of these patients at examination 2. The malignant lesions in 17 of 18 patients with digestive system carcinoma showed SUVmax values ≥2.5 and only one patient had an SUVmax value 18 F-FDG PET imaging is an important noninvasive method for the differentiation of malignant and nonmalignant lesions

  14. Real-time digital simulation of power electronics systems with Neutral Point Piloted multilevel inverter using FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Rakotozafy, Mamianja [Groupe de Recherches en Electrotechnique et Electronique de Nancy (GREEN), Faculte des Sciences et Techniques, BP 70239, 54506 Vandoeuvre Cedex (France); CONVERTEAM SAS, Parc d' activites Techn' hom, 24 avenue du Marechal Juin, BP 40437, 90008 Belfort Cedex (France); Poure, Philippe [Laboratoire d' Instrumentation Electronique de Nancy (LIEN), Faculte des Sciences et Techniques, BP 70239, 54506 Vandoeuvre Cedex (France); Saadate, Shahrokh [Groupe de Recherches en Electrotechnique et Electronique de Nancy (GREEN), Faculte des Sciences et Techniques, BP 70239, 54506 Vandoeuvre Cedex (France); Bordas, Cedric; Leclere, Loic [CONVERTEAM SAS, Parc d' activites Techn' hom, 24 avenue du Marechal Juin, BP 40437, 90008 Belfort Cedex (France)

    2011-02-15

    Most of actual real time simulation platforms have practically about ten microseconds as minimum calculation time step, mainly due to computation limits such as processing speed, architecture adequacy and modeling complexities. Therefore, simulation of fast switching converters' instantaneous models requires smaller computing time step. The approach presented in this paper proposes an answer to such limited modeling accuracies and computational bandwidth of the currently available digital simulators.As an example, the authors present a low cost, flexible and high performance FPGA-based real-time digital simulator for a complete complex power system with Neutral Point Piloted (NPP) three-level inverter. The proposed real-time simulator can model accurately and efficiently the complete power system, reducing costs, physical space and avoiding any damage to the actual equipment in the case of any dysfunction of the digital controller prototype. The converter model is computed at a small fixed time step as low as 100 ns. Such a computation time step allows high precision account of the gating signals and thus avoids averaging methods and event compensations. Moreover, a novel high performance model of the NPP three-level inverter has also been proposed for FPGA implementation. The proposed FPGA-based simulator models the environment of the NPP converter: the dc link, the RLE load and the digital controller and gating signals. FPGA-based real time simulation results are presented and compared with offline results obtained using PLECS software. They validate the efficiency and accuracy of the modeling for the proposed high performance FPGA-based real-time simulation approach. This paper also introduces new potential FPGA-based applications such as low cost real time simulator for power systems by developing a library of flexible and portable models for power converters, electrical machines and drives. (author)

  15. Risk factors for hyperglycemia in pregnancy in the DALI study differ by period of pregnancy and OGTT time point

    DEFF Research Database (Denmark)

    Mendoza, Lilian C; Harreiter, Jürgen; Simmons, David

    2018-01-01

    maternal and current pregnancy characteristics. STATISTICAL ANALYSIS: Multivariate logistic regression. RESULTS Clinical characteristics independently associated with GDM/overt diabetes were: at ≤19+6 weeks, previous abnormal glucose tolerance (OR 3.11; CI95 1.41-6.85), previous GDM (OR 2.22; CI95 1......; at 35-37 weeks, maternal height (OR 0.41; CI95 0.20-0.87 for upper tertile). Clinical characteristics independently associated with GDM/overt diabetes differed by OGTT time point (e.g. at ≤19+6 weeks, neck circumference was associated with abnormal fasting but not postchallenge glucose). CONCLUSION...

  16. Sequential Monte Carlo with Highly Informative Observations

    OpenAIRE

    Del Moral, Pierre; Murray, Lawrence M.

    2014-01-01

    We propose sequential Monte Carlo (SMC) methods for sampling the posterior distribution of state-space models under highly informative observation regimes, a situation in which standard SMC methods can perform poorly. A special case is simulating bridges between given initial and final values. The basic idea is to introduce a schedule of intermediate weighting and resampling times between observation times, which guide particles towards the final state. This can always be done for continuous-...

  17. Sequential compression biomechanical device in patients with critical limb ischemia and nonreconstructible peripheral vascular disease.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2011-08-01

    Critical limb ischemia (CLI) patients who are unsuitable for intervention face the dire prospect of primary amputation. Sequential compression biomechanical device (SCBD) therapy provides a limb salvage option for these patients. This study assessed the outcome of SCBD in severe CLI patients who otherwise would face an amputation. Primary end points were limb salvage and 30-day mortality. Secondary end points were hemodynamic outcomes (increase in popliteal artery flow and toe pressure), ulcer healing, quality-adjusted time without symptoms of disease or toxicity of treatment (Q-TwiST), and cost-effectiveness.

  18. Plane-Based Sampling for Ray Casting Algorithm in Sequential Medical Images

    Science.gov (United States)

    Lin, Lili; Chen, Shengyong; Shao, Yan; Gu, Zichun

    2013-01-01

    This paper proposes a plane-based sampling method to improve the traditional Ray Casting Algorithm (RCA) for the fast reconstruction of a three-dimensional biomedical model from sequential images. In the novel method, the optical properties of all sampling points depend on the intersection points when a ray travels through an equidistant parallel plan cluster of the volume dataset. The results show that the method improves the rendering speed at over three times compared with the conventional algorithm and the image quality is well guaranteed. PMID:23424608

  19. Validation and Assessment of Multi-GNSS Real-Time Precise Point Positioning in Simulated Kinematic Mode Using IGS Real-Time Service

    Directory of Open Access Journals (Sweden)

    Liang Wang

    2018-02-01

    Full Text Available Precise Point Positioning (PPP is a popular technology for precise applications based on the Global Navigation Satellite System (GNSS. Multi-GNSS combined PPP has become a hot topic in recent years with the development of multiple GNSSs. Meanwhile, with the operation of the real-time service (RTS of the International GNSS Service (IGS agency that provides satellite orbit and clock corrections to broadcast ephemeris, it is possible to obtain the real-time precise products of satellite orbits and clocks and to conduct real-time PPP. In this contribution, the real-time multi-GNSS orbit and clock corrections of the CLK93 product are applied for real-time multi-GNSS PPP processing, and its orbit and clock qualities are investigated, first with a seven-day experiment by comparing them with the final multi-GNSS precise product ‘GBM’ from GFZ. Then, an experiment involving real-time PPP processing for three stations in the Multi-GNSS Experiment (MGEX network with a testing period of two weeks is conducted in order to evaluate the convergence performance of real-time PPP in a simulated kinematic mode. The experimental result shows that real-time PPP can achieve a convergence performance of less than 15 min for an accuracy level of 20 cm. Finally, the real-time data streams from 12 globally distributed IGS/MGEX stations for one month are used to assess and validate the positioning accuracy of real-time multi-GNSS PPP. The results show that the simulated kinematic positioning accuracy achieved by real-time PPP on different stations is about 3.0 to 4.0 cm for the horizontal direction and 5.0 to 7.0 cm for the three-dimensional (3D direction.

  20. Performance evaluation of FSO system using wavelength and time diversity over malaga turbulence channel with pointing errors

    Science.gov (United States)

    Balaji, K. A.; Prabu, K.

    2018-03-01

    There is an immense demand for high bandwidth and high data rate systems, which is fulfilled by wireless optical communication or free space optics (FSO). Hence FSO gained a pivotal role in research which has a added advantage of both cost-effective and licence free huge bandwidth. Unfortunately the optical signal in free space suffers from irradiance and phase fluctuations due to atmospheric turbulence and pointing errors which deteriorates the signal and degrades the performance of communication system over longer distance which is undesirable. In this paper, we have considered polarization shift keying (POLSK) system applied with wavelength and time diversity technique over Malaga(M)distribution to mitigate turbulence induced fading. We derived closed form mathematical expressions for estimating the systems outage probability and average bit error rate (BER). Ultimately from the results we can infer that wavelength and time diversity schemes enhances these systems performance.

  1. Dual-time-point FDG-PET/CT Imaging of Temporal Bone Chondroblastoma: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Akira Toriihara

    2015-07-01

    Full Text Available Temporal bone chondroblastoma is an extremely rare benign bone tumor. We encountered two cases showing similar imaging findings on computed tomography (CT, magnetic resonance imaging (MRI, and dual-time-point 18F-fluorodeoxyglucose (18F-FDG positron emission tomography (PET/CT. In both cases, CT images revealed temporal bone defects and sclerotic changes around the tumor. Most parts of the tumor showed low signal intensity on T2- weighted MRI images and non-uniform enhancement on gadolinium contrast-enhanced T1-weighted images. No increase in signal intensity was noted in diffusion-weighted images. Dual-time-point PET/CT showed markedly elevated 18F-FDG uptake, which increased from the early to delayed phase. Nevertheless, immunohistochemical analysis of the resected tumor tissue revealed weak expression of glucose transporter-1 and hexokinase II in both tumors. Temporal bone tumors, showing markedly elevated 18F-FDG uptake, which increases from the early to delayed phase on PET/CT images, may be diagnosed as malignant bone tumors. Therefore, the differential diagnosis should include chondroblastoma in combination with its characteristic findings on CT and MRI.

  2. A one-sided sequential test

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Lux, I. [Hungarian Academy of Sciences, Budapest (Hungary). Atomic Energy Research Inst.

    1996-04-16

    The applicability of the classical sequential probability ratio testing (SPRT) for early failure detection problems is limited by the fact that there is an extra time delay between the occurrence of the failure and its first recognition. Chien and Adams developed a method to minimize this time for the case when the problem can be formulated as testing the mean value of a Gaussian signal. In our paper we propose a procedure that can be applied for both mean and variance testing and that minimizes the time delay. The method is based on a special parametrization of the classical SPRT. The one-sided sequential tests (OSST) can reproduce the results of the Chien-Adams test when applied for mean values. (author).

  3. Dual-time-point O-(2-[18F]fluoroethyl)-L-tyrosine PET for grading of cerebral gliomas

    International Nuclear Information System (INIS)

    Lohmann, Philipp; Herzog, Hans; Rota Kops, Elena; Stoffels, Gabriele; Judov, Natalie; Filss, Christian; Tellmann, Lutz; Galldiks, Norbert; Weiss, Carolin; Sabel, Michael; Coenen, Heinz Hubert; Shah, Nadim Jon; Langen, Karl-Josef

    2015-01-01

    We aimed to evaluate the diagnostic potential of dual-time-point imaging with positron emission tomography (PET) using O-(2-[ 18 F]fluoroethyl)-L-tyrosine ( 18 F-FET) for non-invasive grading of cerebral gliomas compared with a dynamic approach. Thirty-six patients with histologically confirmed cerebral gliomas (21 primary, 15 recurrent; 24 high-grade, 12 low-grade) underwent dynamic PET from 0 to 50 min post-injection (p.i.) of 18 F-FET, and additionally from 70 to 90 min p.i. Mean tumour-to-brain ratios (TBR mean ) of 18 F-FET uptake were determined in early (20-40 min p.i.) and late (70-90 min p.i.) examinations. Time-activity curves (TAC) of the tumours from 0 to 50 min after injection were assigned to different patterns. The diagnostic accuracy of changes of 18 F-FET uptake between early and late examinations for tumour grading was compared to that of curve pattern analysis from 0 to 50 min p.i. of 18 F-FET. The diagnostic accuracy of changes of the TBR mean of 18 F-FET PET uptake between early and late examinations for the identification of HGG was 81 % (sensitivity 83 %; specificity 75 %; cutoff - 8 %; p < 0.001), and 83 % for curve pattern analysis (sensitivity 88 %; specificity 75 %; p < 0.001). Dual-time-point imaging of 18 F-FET uptake in gliomas achieves diagnostic accuracy for tumour grading that is similar to the more time-consuming dynamic data acquisition protocol. (orig.)

  4. Dual-time-point O-(2-[{sup 18}F]fluoroethyl)-L-tyrosine PET for grading of cerebral gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Lohmann, Philipp; Herzog, Hans; Rota Kops, Elena; Stoffels, Gabriele; Judov, Natalie; Filss, Christian; Tellmann, Lutz [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); Galldiks, Norbert [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); University of Cologne, Department of Neurology, Cologne (Germany); Weiss, Carolin [University of Cologne, Department of Neurosurgery, Cologne (Germany); Sabel, Michael [Heinrich-Heine University, Department of Neurosurgery, Duesseldorf (Germany); Coenen, Heinz Hubert [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain, Juelich (Germany); Shah, Nadim Jon [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain, Juelich (Germany); RWTH Aachen University Hospital, Department of Neurology, Aachen (Germany); Langen, Karl-Josef [Forschungszentrum Juelich, Institute of Neuroscience and Medicine, Juelich (Germany); RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen (Germany); Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain, Juelich (Germany)

    2015-10-15

    We aimed to evaluate the diagnostic potential of dual-time-point imaging with positron emission tomography (PET) using O-(2-[{sup 18}F]fluoroethyl)-L-tyrosine ({sup 18}F-FET) for non-invasive grading of cerebral gliomas compared with a dynamic approach. Thirty-six patients with histologically confirmed cerebral gliomas (21 primary, 15 recurrent; 24 high-grade, 12 low-grade) underwent dynamic PET from 0 to 50 min post-injection (p.i.) of {sup 18}F-FET, and additionally from 70 to 90 min p.i. Mean tumour-to-brain ratios (TBR{sub mean}) of {sup 18}F-FET uptake were determined in early (20-40 min p.i.) and late (70-90 min p.i.) examinations. Time-activity curves (TAC) of the tumours from 0 to 50 min after injection were assigned to different patterns. The diagnostic accuracy of changes of {sup 18}F-FET uptake between early and late examinations for tumour grading was compared to that of curve pattern analysis from 0 to 50 min p.i. of {sup 18}F-FET. The diagnostic accuracy of changes of the TBR{sub mean} of {sup 18}F-FET PET uptake between early and late examinations for the identification of HGG was 81 % (sensitivity 83 %; specificity 75 %; cutoff - 8 %; p < 0.001), and 83 % for curve pattern analysis (sensitivity 88 %; specificity 75 %; p < 0.001). Dual-time-point imaging of {sup 18}F-FET uptake in gliomas achieves diagnostic accuracy for tumour grading that is similar to the more time-consuming dynamic data acquisition protocol. (orig.)

  5. A Time Scheduling Model of Logistics Service Supply Chain Based on the Customer Order Decoupling Point: A Perspective from the Constant Service Operation Time

    Science.gov (United States)

    Yang, Yi; Xu, Haitao; Liu, Xiaoyan; Wang, Yijia; Liang, Zhicheng

    2014-01-01

    In mass customization logistics service, reasonable scheduling of the logistics service supply chain (LSSC), especially time scheduling, is benefit to increase its competitiveness. Therefore, the effect of a customer order decoupling point (CODP) on the time scheduling performance should be considered. To minimize the total order operation cost of the LSSC, minimize the difference between the expected and actual time of completing the service orders, and maximize the satisfaction of functional logistics service providers, this study establishes an LSSC time scheduling model based on the CODP. Matlab 7.8 software is used in the numerical analysis for a specific example. Results show that the order completion time of the LSSC can be delayed or be ahead of schedule but cannot be infinitely advanced or infinitely delayed. Obtaining the optimal comprehensive performance can be effective if the expected order completion time is appropriately delayed. The increase in supply chain comprehensive performance caused by the increase in the relationship coefficient of logistics service integrator (LSI) is limited. The relative concern degree of LSI on cost and service delivery punctuality leads to not only changes in CODP but also to those in the scheduling performance of the LSSC. PMID:24715818

  6. A time scheduling model of logistics service supply chain based on the customer order decoupling point: a perspective from the constant service operation time.

    Science.gov (United States)

    Liu, Weihua; Yang, Yi; Xu, Haitao; Liu, Xiaoyan; Wang, Yijia; Liang, Zhicheng

    2014-01-01

    In mass customization logistics service, reasonable scheduling of the logistics service supply chain (LSSC), especially time scheduling, is benefit to increase its competitiveness. Therefore, the effect of a customer order decoupling point (CODP) on the time scheduling performance should be considered. To minimize the total order operation cost of the LSSC, minimize the difference between the expected and actual time of completing the service orders, and maximize the satisfaction of functional logistics service providers, this study establishes an LSSC time scheduling model based on the CODP. Matlab 7.8 software is used in the numerical analysis for a specific example. Results show that the order completion time of the LSSC can be delayed or be ahead of schedule but cannot be infinitely advanced or infinitely delayed. Obtaining the optimal comprehensive performance can be effective if the expected order completion time is appropriately delayed. The increase in supply chain comprehensive performance caused by the increase in the relationship coefficient of logistics service integrator (LSI) is limited. The relative concern degree of LSI on cost and service delivery punctuality leads to not only changes in CODP but also to those in the scheduling performance of the LSSC.

  7. Induction of simultaneous and sequential malolactic fermentation in durian wine.

    Science.gov (United States)

    Taniasuri, Fransisca; Lee, Pin-Rou; Liu, Shao-Quan

    2016-08-02

    This study represented for the first time the impact of malolactic fermentation (MLF) induced by Oenococcus oeni and its inoculation strategies (simultaneous vs. sequential) on the fermentation performance as well as aroma compound profile of durian wine. There was no negative impact of simultaneous inoculation of O. oeni and Saccharomyces cerevisiae on the growth and fermentation kinetics of S. cerevisiae as compared to sequential fermentation. Simultaneous MLF did not lead to an excessive increase in volatile acidity as compared to sequential MLF. The kinetic changes of organic acids (i.e. malic, lactic, succinic, acetic and α-ketoglutaric acids) varied with simultaneous and sequential MLF relative to yeast alone. MLF, regardless of inoculation mode, resulted in higher production of fermentation-derived volatiles as compared to control (alcoholic fermentation only), including esters, volatile fatty acids, and terpenes, except for higher alcohols. Most indigenous volatile sulphur compounds in durian were decreased to trace levels with little differences among the control, simultaneous and sequential MLF. Among the different wines, the wine with simultaneous MLF had higher concentrations of terpenes and acetate esters while sequential MLF had increased concentrations of medium- and long-chain ethyl esters. Relative to alcoholic fermentation only, both simultaneous and sequential MLF reduced acetaldehyde substantially with sequential MLF being more effective. These findings illustrate that MLF is an effective and novel way of modulating the volatile and aroma compound profile of durian wine. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. TRANSIT TIME THROUGH THE BORDER-CROSSING POINTS: THE CASE STUDY OF THE EU'S ROAD BCP WITH MOLDAVIA

    Directory of Open Access Journals (Sweden)

    Mihaela POPA

    2016-06-01

    Full Text Available . This paper provides an overview on the ACROSSEE project (funded by the ERDF under the SEE program, its objectives, general methodology, and the main results. Moreover, the main survey results are presented as they relate to the Romanian road and rail border-crossing points (BCPs with the Eastern neighbourly country, Moldavia. Results include the actual status of the road BCP, surveys on exiting and entering traffic flows, answers to specific questionnaires of the truck and car drivers in relation with origin-destination of the trips, average waiting time in queue and time required for procedures and controls. Discussion on the mathematical modelling is presented and a provisional simulation model is developed, using ARENA software. The early results are used in order to introduce the need for future assessment of the transit time in a road BCP, with the main purpose: the substantiation of the strategic and operational actions for improvements in trade and transport crossings of the EU borders, considering the need for more vigilant and less time-consuming checks at the outside borders of the EU.

  9. Sequential Scintigraphy in Renal Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Winkel, K. zum; Harbst, H.; Schenck, P.; Franz, H. E.; Ritz, E.; Roehl, L.; Ziegler, M.; Ammann, W.; Maier-Borst, W. [Institut Fuer Nuklearmedizin, Deutsches Krebsforschungszentrum, Heidelberg, Federal Republic of Germany (Germany)

    1969-05-15

    Based on experience gained from more than 1600 patients with proved or suspected kidney diseases and on results on extended studies with dogs, sequential scintigraphy was performed after renal transplantation in dogs. After intravenous injection of 500 {mu}Ci. {sup 131}I-Hippuran scintiphotos were taken during the first minute with an exposure time of 15 sec each and thereafter with an exposure of 2 min up to at least 16 min.. Several examinations were evaluated digitally. 26 examinations were performed on 11 dogs with homotransplanted kidneys. Immediately after transplantation the renal function was almost normal arid the bladder was filled in due time. At the beginning of rejection the initial uptake of radioactive Hippuran was reduced. The intrarenal transport became delayed; probably the renal extraction rate decreased. Corresponding to the development of an oedema in the transplant the uptake area increased in size. In cases of thrombosis of the main artery there was no evidence of any uptake of radioactivity in the transplant. Similar results were obtained in 41 examinations on 15 persons. Patients with postoperative anuria due to acute tubular necrosis showed still some uptake of radioactivity contrary to those with thrombosis of the renal artery, where no uptake was found. In cases of rejection the most frequent signs were a reduced initial uptake and a delayed intrarenal transport of radioactive Hippuran. Infarction could be detected by a reduced uptake in distinct areas of the transplant. (author)

  10. Parcellation of the Healthy Neonatal Brain into 107 Regions Using Atlas Propagation through Intermediate Time Points in Childhood.

    Science.gov (United States)

    Blesa, Manuel; Serag, Ahmed; Wilkinson, Alastair G; Anblagan, Devasuda; Telford, Emma J; Pataky, Rozalia; Sparrow, Sarah A; Macnaught, Gillian; Semple, Scott I; Bastin, Mark E; Boardman, James P

    2016-01-01

    Neuroimage analysis pipelines rely on parcellated atlases generated from healthy individuals to provide anatomic context to structural and diffusion MRI data. Atlases constructed using adult data introduce bias into studies of early brain development. We aimed to create a neonatal brain atlas of healthy subjects that can be applied to multi-modal MRI data. Structural and diffusion 3T MRI scans were acquired soon after birth from 33 typically developing neonates born at term (mean postmenstrual age at birth 39(+5) weeks, range 37(+2)-41(+6)). An adult brain atlas (SRI24/TZO) was propagated to the neonatal data using temporal registration via childhood templates with dense temporal samples (NIH Pediatric Database), with the final atlas (Edinburgh Neonatal Atlas, ENA33) constructed using the Symmetric Group Normalization (SyGN) method. After this step, the computed final transformations were applied to T2-weighted data, and fractional anisotropy, mean diffusivity, and tissue segmentations to provide a multi-modal atlas with 107 anatomical regions; a symmetric version was also created to facilitate studies of laterality. Volumes of each region of interest were measured to provide reference data from normal subjects. Because this atlas is generated from step-wise propagation of adult labels through intermediate time points in childhood, it may serve as a useful starting point for modeling brain growth during development.

  11. Parcellation of the healthy neonatal brain into 107 regions using atlas propagation through intermediate time points in childhood

    Directory of Open Access Journals (Sweden)

    Manuel eBlesa Cabez

    2016-05-01

    Full Text Available Neuroimage analysis pipelines rely on parcellated atlases generated from healthy individuals to provide anatomic context to structural and diffusion MRI data. Atlases constructed using adult data introduce bias into studies of early brain development. We aimed to create a neonatal brain atlas of healthy subjects that can be applied to multi-modal MRI data. Structural and diffusion 3T MRI scans were acquired soon after birth from 33 typically developing neonates born at term (mean postmenstrual age at birth 39+5 weeks, range 37+2-41+6. An adult brain atlas (SRI24/TZO was propagated to the neonatal data using temporal registration via childhood templates with dense temporal samples (NIH Pediatric Database, with the final atlas (Edinburgh Neonatal Atlas, ENA33 constructed using the Symmetric Group Normalization method. After this step, the computed final transformations were applied to T2-weighted data, and fractional anisotropy, mean diffusivity, and tissue segmentations to provide a multi-modal atlas with 107 anatomical regions; a symmetric version was also created to facilitate studies of laterality. Volumes of each region of interest were measured to provide reference data from normal subjects. Because this atlas is generated from step-wise propagation of adult labels through intermediate time points in childhood, it may serve as a useful starting point for modelling brain growth during development.

  12. Point-and-stare operation and high-speed image acquisition in real-time hyperspectral imaging

    Science.gov (United States)

    Driver, Richard D.; Bannon, David P.; Ciccone, Domenic; Hill, Sam L.

    2010-04-01

    The design and optical performance of a small-footprint, low-power, turnkey, Point-And-Stare hyperspectral analyzer, capable of fully automated field deployment in remote and harsh environments, is described. The unit is packaged for outdoor operation in an IP56 protected air-conditioned enclosure and includes a mechanically ruggedized fully reflective, aberration-corrected hyperspectral VNIR (400-1000 nm) spectrometer with a board-level detector optimized for point and stare operation, an on-board computer capable of full system data-acquisition and control, and a fully functioning internal hyperspectral calibration system for in-situ system spectral calibration and verification. Performance data on the unit under extremes of real-time survey operation and high spatial and high spectral resolution will be discussed. Hyperspectral acquisition including full parameter tracking is achieved by the addition of a fiber-optic based downwelling spectral channel for solar illumination tracking during hyperspectral acquisition and the use of other sensors for spatial and directional tracking to pinpoint view location. The system is mounted on a Pan-And-Tilt device, automatically controlled from the analyzer's on-board computer, making the HyperspecTM particularly adaptable for base security, border protection and remote deployments. A hyperspectral macro library has been developed to control hyperspectral image acquisition, system calibration and scene location control. The software allows the system to be operated in a fully automatic mode or under direct operator control through a GigE interface.

  13. An approach for real-time fast point positioning of the BeiDou Navigation Satellite System using augmentation information

    Science.gov (United States)

    Tu, Rui; Zhang, Rui; Zhang, Pengfei; Liu, Jinhai; Lu, Xiaochun

    2018-07-01

    This study proposes an approach to facilitate real-time fast point positioning of the BeiDou Navigation Satellite System (BDS) based on regional augmentation information. We term this as the precise positioning based on augmentation information (BPP) approach. The coordinates of the reference stations were highly constrained to extract the augmentation information, which contained not only the satellite orbit clock error correlated with the satellite running state, but also included the atmosphere error and unmodeled error, which are correlated with the spatial and temporal states. Based on these mixed augmentation corrections, a precise point positioning (PPP) model could be used for the coordinates estimation of the user stations, and the float ambiguity could be easily fixed for the single-difference between satellites. Thus, this technique provided a quick and high-precision positioning service. Three different datasets with small, medium, and large baselines (0.6 km, 30 km and 136 km) were used to validate the feasibility and effectiveness of the proposed BPP method. The validations showed that using the BPP model, 1–2 cm positioning service can be provided in a 100 km wide area after just 2 s of initialization. Thus, as the proposed approach not only capitalized on both PPP and RTK but also provided consistent application, it can be used for area augmentation positioning.

  14. A different outlook on time: visual and auditory month names elicit different mental vantage points for a time-space synaesthete.

    Science.gov (United States)

    Jarick, Michelle; Dixon, Mike J; Stewart, Mark T; Maxwell, Emily C; Smilek, Daniel

    2009-01-01

    Synaesthesia is a fascinating condition whereby individuals report extraordinary experiences when presented with ordinary stimuli. Here we examined an individual (L) who experiences time units (i.e., months of the year and hours of the day) as occupying specific spatial locations (January is 30 degrees to the left of midline). This form of time-space synaesthesia has been recently investigated by Smilek et al. (2007) who demonstrated that synaesthetic time-space associations are highly consistent, occur regardless of intention, and can direct spatial attention. We extended this work by showing that for the synaesthete L, her time-space vantage point changes depending on whether the time units are seen or heard. For example, when L sees the word JANUARY, she reports experiencing January on her left side, however when she hears the word "January" she experiences the month on her right side. L's subjective reports were validated using a spatial cueing paradigm. The names of months were centrally presented followed by targets on the left or right. L was faster at detecting targets in validly cued locations relative to invalidly cued locations both for visually presented cues (January orients attention to the left) and for aurally presented cues (January orients attention to the right). We replicated this difference in visual and aural cueing effects using hour of the day. Our findings support previous research showing that time-space synaesthesia can bias visual spatial attention, and further suggest that for this synaesthete, time-space associations differ depending on whether they are visually or aurally induced.

  15. Framework for sequential approximate optimization

    NARCIS (Netherlands)

    Jacobs, J.H.; Etman, L.F.P.; Keulen, van F.; Rooda, J.E.

    2004-01-01

    An object-oriented framework for Sequential Approximate Optimization (SAO) isproposed. The framework aims to provide an open environment for thespecification and implementation of SAO strategies. The framework is based onthe Python programming language and contains a toolbox of Python

  16. [Hypothesis on the equilibrium point and variability of amplitude, speed and time of single-joint movement].

    Science.gov (United States)

    Latash, M; Gottleib, G

    1990-01-01

    Problems of single-joint movement variability are analysed in the framework of the equilibrium-point hypothesis (the lambda-model). Control of the movements is described with three parameters related to movement amplitude speed, and time. Three strategies emerge from this description. Only one of them is likely to lead to a Fitts' type speed-accuracy trade-off. Experiments were performed to test one of the predictions of the model. Subjects performed identical sets of single-joint fast movements with open or closed eyes and some-what different instructions. Movements performed with closed eyes were characterized with higher peak speeds and unchanged variability in seeming violation of the Fitt's law and in a good correspondence to the model.

  17. Enumerating the Hidden Homeless: Strategies to Estimate the Homeless Gone Missing From a Point-in-Time Count

    Directory of Open Access Journals (Sweden)

    Agans Robert P.

    2014-06-01

    Full Text Available To receive federal homeless funds, communities are required to produce statistically reliable, unduplicated counts or estimates of homeless persons in sheltered and unsheltered locations during a one-night period (within the last ten days of January called a point-in-time (PIT count. In Los Angeles, a general population telephone survey was implemented to estimate the number of unsheltered homeless adults who are hidden from view during the PIT count. Two estimation approaches were investigated: i the number of homeless persons identified as living on private property, which employed a conventional household weight for the estimated total (Horvitz-Thompson approach; and ii the number of homeless persons identified as living on a neighbor’s property, which employed an additional adjustment derived from the size of the neighborhood network to estimate the total (multiplicity-based approach. This article compares the results of these two methods and discusses the implications therein.

  18. POD for Real-Time Simulation of Hyperelastic Soft Biological Tissue Using the Point Collocation Method of Finite Spheres

    Directory of Open Access Journals (Sweden)

    Suleiman Banihani

    2013-01-01

    Full Text Available The point collocation method of finite spheres (PCMFS is used to model the hyperelastic response of soft biological tissue in real time within the framework of virtual surgery simulation. The proper orthogonal decomposition (POD model order reduction (MOR technique was used to achieve reduced-order model of the problem, minimizing computational cost. The PCMFS is a physics-based meshfree numerical technique for real-time simulation of surgical procedures where the approximation functions are applied directly on the strong form of the boundary value problem without the need for integration, increasing computational efficiency. Since computational speed has a significant role in simulation of surgical procedures, the proposed technique was able to model realistic nonlinear behavior of organs in real time. Numerical results are shown to demonstrate the effectiveness of the new methodology through a comparison between full and reduced analyses for several nonlinear problems. It is shown that the proposed technique was able to achieve good agreement with the full model; moreover, the computational and data storage costs were significantly reduced.

  19. Locating single-point sources from arrival times containing large picking errors (LPEs): the virtual field optimization method (VFOM)

    Science.gov (United States)

    Li, Xi-Bing; Wang, Ze-Wei; Dong, Long-Jun

    2016-01-01

    Microseismic monitoring systems using local location techniques tend to be timely, automatic and stable. One basic requirement of these systems is the automatic picking of arrival times. However, arrival times generated by automated techniques always contain large picking errors (LPEs), which may make the location solution unreliable and cause the integrated system to be unstable. To overcome the LPE issue, we propose the virtual field optimization method (VFOM) for locating single-point sources. In contrast to existing approaches, the VFOM optimizes a continuous and virtually established objective function to search the space for the common intersection of the hyperboloids, which is determined by sensor pairs other than the least residual between the model-calculated and measured arrivals. The results of numerical examples and in-site blasts show that the VFOM can obtain more precise and stable solutions than traditional methods when the input data contain LPEs. Furthermore, we discuss the impact of LPEs on objective functions to determine the LPE-tolerant mechanism, velocity sensitivity and stopping criteria of the VFOM. The proposed method is also capable of locating acoustic sources using passive techniques such as passive sonar detection and acoustic emission.

  20. Comparing two Poisson populations sequentially: an application

    International Nuclear Information System (INIS)

    Halteman, E.J.

    1986-01-01

    Rocky Flats Plant in Golden, Colorado monitors each of its employees for radiation exposure. Excess exposure is detected by comparing the means of two Poisson populations. A sequential probability ratio test (SPRT) is proposed as a replacement for the fixed sample normal approximation test. A uniformly most efficient SPRT exists, however logistics suggest using a truncated SPRT. The truncated SPRT is evaluated in detail and shown to possess large potential savings in average time spent by employees in the monitoring process

  1. Atmospheric plume progression as a function of time and distance from the release point for radioactive isotopes.

    Science.gov (United States)

    Eslinger, Paul W; Bowyer, Ted W; Cameron, Ian M; Hayes, James C; Miley, Harry S

    2015-10-01

    The radionuclide network of the International Monitoring System comprises up to 80 stations around the world that have aerosol and xenon monitoring systems designed to detect releases of radioactive materials to the atmosphere from nuclear explosions. A rule of thumb description of plume concentration and duration versus time and distance from the release point is useful when designing and deploying new sample collection systems. This paper uses plume development from atmospheric transport modeling to provide a power-law rule describing atmospheric dilution factors as a function of distance from the release point. Consider the plume center-line concentration seen by a ground-level sampler as a function of time based on a short-duration ground-level release of a nondepositing radioactive tracer. The concentration C (Bq m(-3)) near the ground varies with distance from the source with the relationship C=R×A(D,C) ×e (-λ(-1.552+0.0405×D)) × 5.37×10(-8) × D(-2.35) where R is the release magnitude (Bq), D is the separation distance (km) from the ground level release to the measurement location, λ is the decay constant (h(-1)) for the radionuclide of interest and AD,C is an attenuation factor that depends on the length of the sample collection period. This relationship is based on the median concentration for 10 release locations with different geographic characteristics and 365 days of releases at each location, and it has an R(2) of 0.99 for 32 distances from 100 to 3000 km. In addition, 90 percent of the modeled plumes fall within approximately one order of magnitude of this curve for all distances. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Sequentially pulsed traveling wave accelerator

    Science.gov (United States)

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA; Poole, Brian R [Tracy, CA

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  3. Near Real Time Change-Point detection in Optical and Thermal Infrared Time Series Using Bayesian Inference over the Dry Chaco Forest

    Science.gov (United States)

    Barraza Bernadas, V.; Grings, F.; Roitberg, E.; Perna, P.; Karszenbaum, H.

    2017-12-01

    The Dry Chaco region (DCF) has the highest absolute deforestation rates of all Argentinian forests. The most recent report indicates a current deforestation rate of 200,000 Ha year-1. In order to better monitor this process, DCF was chosen to implement an early warning program for illegal deforestation. Although the area is intensively studied using medium resolution imagery (Landsat), the products obtained have a yearly pace and therefore unsuited for an early warning program. In this paper, we evaluated the performance of an online Bayesian change-point detection algorithm for MODIS Enhanced Vegetation Index (EVI) and Land Surface Temperature (LST) datasets. The goal was to to monitor the abrupt changes in vegetation dynamics associated with deforestation events. We tested this model by simulating 16-day EVI and 8-day LST time series with varying amounts of seasonality, noise, length of the time series and by adding abrupt changes with different magnitudes. This model was then tested on real satellite time series available through the Google Earth Engine, over a pilot area in DCF, where deforestation was common in the 2004-2016 period. A comparison with yearly benchmark products based on Landsat images is also presented (REDAF dataset). The results shows the advantages of using an automatic model to detect a changepoint in the time series than using only visual inspection techniques. Simulating time series with varying amounts of seasonality and noise, and by adding abrupt changes at different times and magnitudes, revealed that this model is robust against noise, and is not influenced by changes in amplitude of the seasonal component. Furthermore, the results compared favorably with REDAF dataset (near 65% of agreement). These results show the potential to combine LST and EVI to identify deforestation events. This work is being developed within the frame of the national Forest Law for the protection and sustainable development of Native Forest in Argentina in

  4. A mathematical programming approach for sequential clustering of dynamic networks

    Science.gov (United States)

    Silva, Jonathan C.; Bennett, Laura; Papageorgiou, Lazaros G.; Tsoka, Sophia

    2016-02-01

    A common analysis performed on dynamic networks is community structure detection, a challenging problem that aims to track the temporal evolution of network modules. An emerging area in this field is evolutionary clustering, where the community structure of a network snapshot is identified by taking into account both its current state as well as previous time points. Based on this concept, we have developed a mixed integer non-linear programming (MINLP) model, SeqMod, that sequentially clusters each snapshot of a dynamic network. The modularity metric is used to determine the quality of community structure of the current snapshot and the historical cost is accounted for by optimising the number of node pairs co-clustered at the previous time point that remain so in the current snapshot partition. Our method is tested on social networks of interactions among high school students, college students and members of the Brazilian Congress. We show that, for an adequate parameter setting, our algorithm detects the classes that these students belong more accurately than partitioning each time step individually or by partitioning the aggregated snapshots. Our method also detects drastic discontinuities in interaction patterns across network snapshots. Finally, we present comparative results with similar community detection methods for time-dependent networks from the literature. Overall, we illustrate the applicability of mathematical programming as a flexible, adaptable and systematic approach for these community detection problems. Contribution to the Topical Issue "Temporal Network Theory and Applications", edited by Petter Holme.

  5. Change-point analysis of geophysical time-series: application to landslide displacement rate (Séchilienne rock avalanche, France)

    Science.gov (United States)

    Amorese, D.; Grasso, J.-R.; Garambois, S.; Font, M.

    2018-05-01

    The rank-sum multiple change-point method is a robust statistical procedure designed to search for the optimal number and the location of change points in an arbitrary continue or discrete sequence of values. As such, this procedure can be used to analyse time-series data. Twelve years of robust data sets for the Séchilienne (French Alps) rockslide show a continuous increase in average displacement rate from 50 to 280 mm per month, in the 2004-2014 period, followed by a strong decrease back to 50 mm per month in the 2014-2015 period. When possible kinematic phases are tentatively suggested in previous studies, its solely rely on the basis of empirical threshold values. In this paper, we analyse how the use of a statistical algorithm for change-point detection helps to better understand time phases in landslide kinematics. First, we test the efficiency of the statistical algorithm on geophysical benchmark data, these data sets (stream flows and Northern Hemisphere temperatures) being already analysed by independent statistical tools. Second, we apply the method to 12-yr daily time-series of the Séchilienne landslide, for rainfall and displacement data, from 2003 December to 2015 December, in order to quantitatively extract changes in landslide kinematics. We find two strong significant discontinuities in the weekly cumulated rainfall values: an average rainfall rate increase is resolved in 2012 April and a decrease in 2014 August. Four robust changes are highlighted in the displacement time-series (2008 May, 2009 November-December-2010 January, 2012 September and 2014 March), the 2010 one being preceded by a significant but weak rainfall rate increase (in 2009 November). Accordingly, we are able to quantitatively define five kinematic stages for the Séchilienne rock avalanche during this period. The synchronization between the rainfall and displacement rate, only resolved at the end of 2009 and beginning of 2010, corresponds to a remarkable change (fourfold

  6. Breast cancer with low FDG uptake: Characterization by means of dual-time point FDG-PET/CT

    International Nuclear Information System (INIS)

    Zytoon, Ashraf Anas; Murakami, Koji; El-Kholy, Mohamed Ramdan; El-Shorbagy, Emad; Ebied, Osama

    2009-01-01

    Background: Malignant breast lesions usually are differentiated by FDG-PET with a semiquantitative FDG standardized uptake value (SUV) of 2.5. However, the frequency of breast cancer with an SUV of less than or equal to 2.5 is noteworthy, and often present diagnostic challenges. This study was undertaken to evaluate the accuracy of dual-time point FDG-PET/CT with FDG standardized uptake value (SUV) calculation in the characterization of such breast tumors. Methods: Forty-nine female patients with newly diagnosed breast cancer were found to have primary breast cancer with minimally increased FDG uptake and met the criteria for inclusion in this study by having borderline levels of increased FDG uptake (SUVmax less than or equal to 2.5) in the initial FDG-PET/CT images. Consequently, they underwent further delayed phase FDG-PET/CT scan for better evaluation of the disease. Results: Of the 49 cancer lesions; the majority were found to have rising or unvarying dual-time changes in SUVmax (75.5%). The median value of SUVmax increases by 25% between the early and delayed scan. The means ± S.D. of the SUVmax1, the SUVmax2, and the ΔSUVmax% were 1.2 ± 0.6%, 1.3 ± 0.9%, and 5.1 ± 22.4%, respectively. The receiver-operating-characteristic (ROC) analysis proved that the highest accuracy for characterization of malignant breast lesions was obtained when a ΔSUVmax% cut-off value 0.0% was used as criteria for malignant FDG uptake-change over time with sensitivity 75.5%, and false-positive rate 20.4%. Conclusion: These results suggested that dual-time FDG-PET/CT imaging with standardized uptake value (SUV) estimation can improve the accuracy of the test in the evaluation of breast cancer with low FDG uptake.

  7. Mobile, real-time, and point-of-care augmented reality is robust, accurate, and feasible: a prospective pilot study.

    Science.gov (United States)

    Kenngott, Hannes Götz; Preukschas, Anas Amin; Wagner, Martin; Nickel, Felix; Müller, Michael; Bellemann, Nadine; Stock, Christian; Fangerau, Markus; Radeleff, Boris; Kauczor, Hans-Ulrich; Meinzer, Hans-Peter; Maier-Hein, Lena; Müller-Stich, Beat Peter

    2018-06-01

    Augmented reality (AR) systems are currently being explored by a broad spectrum of industries, mainly for improving point-of-care access to data and images. Especially in surgery and especially for timely decisions in emergency cases, a fast and comprehensive access to images at the patient bedside is mandatory. Currently, imaging data are accessed at a distance from the patient both in time and space, i.e., at a specific workstation. Mobile technology and 3-dimensional (3D) visualization of radiological imaging data promise to overcome these restrictions by making bedside AR feasible. In this project, AR was realized in a surgical setting by fusing a 3D-representation of structures of interest with live camera images on a tablet computer using marker-based registration. The intent of this study was to focus on a thorough evaluation of AR. Feasibility, robustness, and accuracy were thus evaluated consecutively in a phantom model and a porcine model. Additionally feasibility was evaluated in one male volunteer. In the phantom model (n = 10), AR visualization was feasible in 84% of the visualization space with high accuracy (mean reprojection error ± standard deviation (SD): 2.8 ± 2.7 mm; 95th percentile = 6.7 mm). In a porcine model (n = 5), AR visualization was feasible in 79% with high accuracy (mean reprojection error ± SD: 3.5 ± 3.0 mm; 95th percentile = 9.5 mm). Furthermore, AR was successfully used and proved feasible within a male volunteer. Mobile, real-time, and point-of-care AR for clinical purposes proved feasible, robust, and accurate in the phantom, animal, and single-trial human model shown in this study. Consequently, AR following similar implementation proved robust and accurate enough to be evaluated in clinical trials assessing accuracy, robustness in clinical reality, as well as integration into the clinical workflow. If these further studies prove successful, AR might revolutionize data access at patient

  8. Guidelines for time-to-event end-point definitions in trials for pancreatic cancer. Results of the DATECAN initiative (Definition for the Assessment of Time-to-event End-points in CANcer trials)

    NARCIS (Netherlands)

    Bonnetain, Franck; Bonsing, Bert; Conroy, Thierry; Dousseau, Adelaide; Glimelius, Bengt; Haustermans, Karin; Lacaine, François; van Laethem, Jean Luc; Aparicio, Thomas; Aust, Daniela; Bassi, Claudio; Berger, Virginie; Chamorey, Emmanuel; Chibaudel, Benoist; Dahan, Laeticia; de Gramont, Aimery; Delpero, Jean Robert; Dervenis, Christos; Ducreux, Michel; Gal, Jocelyn; Gerber, Erich; Ghaneh, Paula; Hammel, Pascal; Hendlisz, Alain; Jooste, Valérie; Labianca, Roberto; Latouche, Aurelien; Lutz, Manfred; Macarulla, Teresa; Malka, David; Mauer, Muriel; Mitry, Emmanuel; Neoptolemos, John; Pessaux, Patrick; Sauvanet, Alain; Tabernero, Josep; Taieb, Julien; van Tienhoven, Geertjan; Gourgou-Bourgade, Sophie; Bellera, Carine; Mathoulin-Pélissier, Simone; Collette, Laurence

    2014-01-01

    Using potential surrogate end-points for overall survival (OS) such as Disease-Free- (DFS) or Progression-Free Survival (PFS) is increasingly common in randomised controlled trials (RCTs). However, end-points are too often imprecisely defined which largely contributes to a lack of homogeneity across

  9. Multichannel, sequential or combined X-ray spectrometry

    International Nuclear Information System (INIS)

    Florestan, J.

    1979-01-01

    X-ray spectrometer qualities and defects are evaluated for sequential and multichannel categories. Multichannel X-ray spectrometer has time-coherency advantage and its results could be more reproducible; on the other hand some spatial incoherency limits low percentage and traces applications, specially when backgrounds are very variable. In this last case, sequential X-ray spectrometer would find again great usefulness [fr

  10. Anatomy of a defective barrier: sequential glove leak detection in a surgical and dental environment.

    Science.gov (United States)

    Albin, M S; Bunegin, L; Duke, E S; Ritter, R R; Page, C P

    1992-02-01

    a) To determine the frequency of perforations in latex surgical gloves before, during, and after surgical and dental procedures; b) to evaluate the topographical distribution of perforations in latex surgical gloves after surgical and dental procedures; and c) to validate methods of testing for latex surgical glove patency. Multitrial tests under in vitro conditions and a prospective sequential patient study using consecutive testing. An outpatient dental clinic at a university dental school, the operating suite in a medical school affiliated with the Veteran's Hospital, and a biomechanics laboratory. Surgeons, scrub nurses, and dental technicians participating in 50 surgical and 50 dental procedures. We collected 679 latex surgical gloves after surgical procedures and tested them for patency by using a water pressure test. We also employed an electronic glove leak detector before donning, after sequential time intervals, and upon termination of 47 surgical (sequential surgical), 50 dental (sequential dental), and in three orthopedic cases where double gloving was used. The electronic glove leak detector was validated by using electronic point-by-point surface probing, fluorescein dye diffusion, as well as detecting glove punctures made with a 27-gauge needle. The random study indicated a leak rate of 33.0% (224 out of 679) in latex surgical gloves; the sequential surgical study demonstrated patency in 203 out of 347 gloves (58.5%); the sequential dental study showed 34 leaks in the 106 gloves used (32.1%); and with double gloving, the leak rate decreased to 25.0% (13 of 52 gloves tested). While the allowable FDA defect rate for unused latex surgical gloves is 1.5%, we noted defect rates in unused gloves of 5.5% in the sequential surgical, 1.9% in the sequential dental, and 4.0% in our electronic glove leak detector validating study. In the sequential surgical study, 52% of the leaks had occurred by 75 mins, and in the sequential dental study, 75% of the leaks

  11. Remarks on sequential designs in risk assessment

    International Nuclear Information System (INIS)

    Seidenfeld, T.

    1982-01-01

    The special merits of sequential designs are reviewed in light of particular challenges that attend risk assessment for human population. The kinds of ''statistical inference'' are distinguished and the problem of design which is pursued is the clash between Neyman-Pearson and Bayesian programs of sequential design. The value of sequential designs is discussed and the Neyman-Pearson vs. Bayesian sequential designs are probed in particular. Finally, warnings with sequential designs are considered, especially in relation to utilitarianism

  12. Transcriptional profiling of suberoylanilide hydroxamic acid (SAHA regulated genes in mineralizing dental pulp cells at early and late time points

    Directory of Open Access Journals (Sweden)

    Henry F. Duncan

    2015-09-01

    Full Text Available Dental pulp tissue can be damaged by a range of irritants, however, if the irritation is removed and/or the tooth is adequately restored, pulp regeneration is possible (Mjör and Tronstad, 1974 [1]. At present, dental restorative materials limit healing by impairing mineralization and repair processes and as a result new biologically-based materials are being developed (Ferracane et al., 2010 [2]. Previous studies have highlighted the benefit of epigenetic modification by histone deacetylase inhibitor (HDACi application to dental pulp cells (DPCs, which induces changes to chromatin architecture, promoting gene expression and cellular-reparative events (Duncan et al., 2013 [3]; Paino et al., 2014 [4]. In this study a genome-wide transcription profiling in epigenetically-modified mineralizing primary DPC cultures was performed, at relatively early and late time-points, to identify differentially regulated transcripts that may provide novel therapeutic targets for use in restorative dentistry. Here we provide detailed methods and analysis on these microarray data which has been deposited in Gene Expression Omnibus (GEO: GSE67175.

  13. Multiple Positive Solutions of a Nonlinear Four-Point Singular Boundary Value Problem with a p-Laplacian Operator on Time Scales

    Directory of Open Access Journals (Sweden)

    Shihuang Hong

    2009-01-01

    Full Text Available We present sufficient conditions for the existence of at least twin or triple positive solutions of a nonlinear four-point singular boundary value problem with a p-Laplacian dynamic equation on a time scale. Our results are obtained via some new multiple fixed point theorems.

  14. Pass-transistor asynchronous sequential circuits

    Science.gov (United States)

    Whitaker, Sterling R.; Maki, Gary K.

    1989-01-01

    Design methods for asynchronous sequential pass-transistor circuits, which result in circuits that are hazard- and critical-race-free and which have added degrees of freedom for the input signals, are discussed. The design procedures are straightforward and easy to implement. Two single-transition-time state assignment methods are presented, and hardware bounds for each are established. A surprising result is that the hardware realizations for each next state variable and output variable is identical for a given flow table. Thus, a state machine with N states and M outputs can be constructed using a single layout replicated N + M times.

  15. FoCuS-point: software for STED fluorescence correlation and time-gated single photon counting

    DEFF Research Database (Denmark)

    Waithe, Dominic; Clausen, Mathias P; Sezgin, Erdinc

    2016-01-01

    to be established quickly and efficiently. AVAILABILITY AND IMPLEMENTATION: FoCuS-point is written in python and is available through the github repository: https://github.com/dwaithe/FCS_point_correlator. Furthermore, compiled versions of the code are available as executables which can be run directly in Linux...

  16. Sequential versus simultaneous market delineation

    DEFF Research Database (Denmark)

    Haldrup, Niels; Møllgaard, Peter; Kastberg Nielsen, Claus

    2005-01-01

    and geographical markets. Using a unique data setfor prices of Norwegian and Scottish salmon, we propose a methodologyfor simultaneous market delineation and we demonstrate that comparedto a sequential approach conclusions will be reversed.JEL: C3, K21, L41, Q22Keywords: Relevant market, econometric delineation......Delineation of the relevant market forms a pivotal part of most antitrustcases. The standard approach is sequential. First the product marketis delineated, then the geographical market is defined. Demand andsupply substitution in both the product dimension and the geographicaldimension...

  17. Sequential logic analysis and synthesis

    CERN Document Server

    Cavanagh, Joseph

    2007-01-01

    Until now, there was no single resource for actual digital system design. Using both basic and advanced concepts, Sequential Logic: Analysis and Synthesis offers a thorough exposition of the analysis and synthesis of both synchronous and asynchronous sequential machines. With 25 years of experience in designing computing equipment, the author stresses the practical design of state machines. He clearly delineates each step of the structured and rigorous design principles that can be applied to practical applications. The book begins by reviewing the analysis of combinatorial logic and Boolean a

  18. Job Demands, Burnout, and Teamwork in Healthcare Professionals Working in a General Hospital that Was Analysed At Two Points in Time

    Directory of Open Access Journals (Sweden)

    Dragan Mijakoski

    2018-04-01

    CONCLUSION: Actual longitudinal study revealed significantly higher mean values of emotional exhaustion and depersonalization in 2014 that could be explained by significantly increased job demands between analysed points in time.

  19. Missing the Mark? A Two Time Point Cohort Study Estimating Intestinal Parasite Prevalence in Informal Settlements in Lima, Peru.

    Science.gov (United States)

    Cooper, Michael Townsend; Searing, Rapha A; Thompson, David M; Bard, David; Carabin, Hélène; Gonzales, Carlos; Zavala, Carmen; Woodson, Kyle; Naifeh, Monique

    2017-01-01

    Objectives: The World Health Organization's (WHO) recommendations list Peru as potentially needing prevention of soil-transmitted helminthiasis (STH). Prevalence of STH varies regionally and remains understudied in the newest informal settlements of the capital city, Lima. The purpose of this study was to evaluate the need for Mass Drug Administration (MDA) of antiparasitic drugs in the newest informal settlements of Lima. The aim of this study was to estimate the season-specific prevalence of STH to determine if these prevalence estimates met the WHO threshold for MDA in 3 informal settlements. Methods : A 2 time point cohort study was conducted among a sample of 140 children aged 1 to 10 years living in 3 purposively sampled informal settlements of Lima, Peru. Children were asked to provide 2 stool samples that were analyzed with the spontaneous sedimentation in tube technique. The season-specific prevalence proportions of MDA-targeted STH were estimated using a hidden (latent) Markov modeling approach to adjust for repeated measurements over the 2 seasons and the imperfect validity of the screening tests. Results : The prevalence of MDA targeted STH was low at 2.2% (95% confidence interval = 0.3% to 6%) and 3.8% (95% confidence interval = 0.7% to 9.3%) among children sampled in the summer and winter months, respectively, when using the most conservative estimate of test sensitivity. These estimates were below the WHO threshold for MDA (20%). Conclusions : Empiric treatment for STH by organizations active in the newest informal settlements is not supported by the data and could contribute to unnecessary medication exposures and poor allocation of resources.

  20. Anisomycin administered in the olfactory bulb and dorsal hippocampus impaired social recognition memory consolidation in different time-points.

    Science.gov (United States)

    Pena, R R; Pereira-Caixeta, A R; Moraes, M F D; Pereira, G S

    2014-10-01

    To identify an individual as familiar, rodents form a specific type of memory named social recognition memory. The olfactory bulb (OB) is an important structure for social recognition memory, while the hippocampus recruitment is still controversial. The present study was designed to elucidate the OB and the dorsal hippocampus contribution to the consolidation of social memory. For that purpose, we tested the effect of anisomycin (ANI), which one of the effects is the inhibition of protein synthesis, on the consolidation of social recognition memory. Swiss adult mice with cannulae implanted into the CA1 region of the dorsal hippocampus or into the OB were exposed to a juvenile during 5 min (training session; TR), and once again 1.5 h or 24 h later to test social short-term memory (S-STM) or social long-term memory (S-LTM), respectively. To study S-LTM consolidation, mice received intra-OB or intra-CA1 infusion of saline or ANI immediately, 3, 6 or 18 h after TR. ANI impaired S-LTM consolidation in the OB, when administered immediately or 6h after TR. In the dorsal hippocampus, ANI was amnesic only if administered 3 h after TR. Furthermore, the infusion of ANI in either OB or CA1, immediately after training, did not affect S-STM. Moreover, ANI administered into the OB did not alter the animal's performance in the buried food-finding task. Altogether, our results suggest the consolidation of S-LTM requires both OB and hippocampus participation, although in different time points. This study may help shedding light on the specific roles of the OB and dorsal hippocampus in social recognition memory. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Relationship of Estimated SHIV Acquisition Time Points During the Menstrual Cycle and Thinning of Vaginal Epithelial Layers in Pigtail Macaques.

    Science.gov (United States)

    Kersh, Ellen N; Ritter, Jana; Butler, Katherine; Ostergaard, Sharon Dietz; Hanson, Debra; Ellis, Shanon; Zaki, Sherif; McNicholl, Janet M

    2015-12-01

    HIV acquisition in the female genital tract remains incompletely understood. Quantitative data on biological HIV risk factors, the influence of reproductive hormones, and infection risk are lacking. We evaluated vaginal epithelial thickness during the menstrual cycle in pigtail macaques (Macaca nemestrina). This model previously revealed increased susceptibility to vaginal infection during and after progesterone-dominated periods in the menstrual cycle. Nucleated and nonnucleated (superficial) epithelial layers were quantitated throughout the menstrual cycle of 16 macaques. We examined the relationship with previously estimated vaginal SHIVSF162P3 acquisition time points in the cycle of 43 different animals repeatedly exposed to low virus doses. In the luteal phase (days 17 to cycle end), the mean vaginal epithelium thinned to 66% of mean follicular thickness (days 1-16; P = 0.007, Mann-Whitney test). Analyzing 4-day segments, the epithelium was thickest on days 9 to 12 and thinned to 31% thereof on days 29 to 32, with reductions of nucleated and nonnucleated layers to 36% and 15% of their previous thickness, respectively. The proportion of animals with estimated SHIV acquisition in each cycle segment correlated with nonnucleated layer thinning (Pearson r = 0.7, P layer thinning (Pearson r = 0.6, P = 0.15). These data provide a detailed picture of dynamic cycle-related changes in the vaginal epithelium of pigtail macaques. Substantial thinning occurred in the superficial, nonnucleated layer, which maintains the vaginal microbiome. The findings support vaginal tissue architecture as susceptibility factor for infection and contribute to our understanding of innate resistance to SHIV infection.

  2. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...... assumed to be normally distributed, and sequential one-sided hypothesis tests on the population standard deviation of the differences against a hypothesised value of 1.5 were performed, employing an alpha spending function. The fixed-sample analysis (N = 45) was compared with the group-sequential analysis...... strategies comprising one (at N = 23), two (at N = 15, 30), or three interim analyses (at N = 11, 23, 34), respectively, which were defined post hoc. RESULTS: When performing interim analyses with one third and two thirds of patients, sufficient agreement could be concluded after the first interim analysis...

  3. Detection of anorectal and cervicovaginal Chlamydia trachomatis infections following azithromycin treatment: prospective cohort study with multiple time-sequential measures of rRNA, DNA, quantitative load and symptoms.

    Directory of Open Access Journals (Sweden)

    Nicole H T M Dukers-Muijrers

    Full Text Available Determination of Chlamydia trachomatis (Ct treatment success is hampered by current assessment methods, which involve a single post-treatment measurement only. Therefore, we evaluated Ct detection by applying multiple laboratory measures on time-sequential post-treatment samples.A prospective cohort study was established with azithromycin-treated (1000 mg Ct patients (44 cervicovaginal and 15 anorectal cases. Each patient provided 18 self-taken samples pre-treatment and for 8 weeks post-treatment (response: 96%; 1,016 samples. Samples were tested for 16S rRNA (TMA, bacterial load (quantitative PCR; Chlamydia plasmid DNA and type (serovar and multilocus sequence typing. Covariates (including behavior, pre-treatment load, anatomic site, symptoms, age, and menstruation were tested for their potential association with positivity and load at 3-8 weeks using regression analyses controlling for repeated measures.By day 9, Ct positivity decreased to 20% and the median load to 0.3 inclusion-forming units (IFU per ml (pre-treatment: 170 IFU/ml. Of the 35 cases who reported no sex, sex with a treated partner or safe sex with a new partner, 40% had detection, i.e. one or more positive samples from 3-8 weeks (same Ct type over time, indicating possible antimicrobial treatment failure. Cases showed intermittent positive detection and the number of positive samples was higher in anorectal cases than in cervicovaginal cases. The highest observed bacterial load between 3-8 weeks post-treatment was 313 IFU/ml, yet the majority (65% of positive samples showed a load of ≤ 2 IFU/ml. Pre-treatment load was found to be associated with later load in anorectal cases.A single test at 3-8 weeks post-treatment frequently misses Ct. Detection reveals intermittent low loads, with an unknown risk of later complications or transmission. These findings warrant critical re-evaluation of the clinical management of single dose azithromycin-treated Ct patients and fuel the debate

  4. Advances in sequential data assimilation and numerical weather forecasting: An Ensemble Transform Kalman-Bucy Filter, a study on clustering in deterministic ensemble square root filters, and a test of a new time stepping scheme in an atmospheric model

    Science.gov (United States)

    Amezcua, Javier

    This dissertation deals with aspects of sequential data assimilation (in particular ensemble Kalman filtering) and numerical weather forecasting. In the first part, the recently formulated Ensemble Kalman-Bucy (EnKBF) filter is revisited. It is shown that the previously used numerical integration scheme fails when the magnitude of the background error covariance grows beyond that of the observational error covariance in the forecast window. Therefore, we present a suitable integration scheme that handles the stiffening of the differential equations involved and doesn't represent further computational expense. Moreover, a transform-based alternative to the EnKBF is developed: under this scheme, the operations are performed in the ensemble space instead of in the state space. Advantages of this formulation are explained. For the first time, the EnKBF is implemented in an atmospheric model. The second part of this work deals with ensemble clustering, a phenomenon that arises when performing data assimilation using of deterministic ensemble square root filters in highly nonlinear forecast models. Namely, an M-member ensemble detaches into an outlier and a cluster of M-1 members. Previous works may suggest that this issue represents a failure of EnSRFs; this work dispels that notion. It is shown that ensemble clustering can be reverted also due to nonlinear processes, in particular the alternation between nonlinear expansion and compression of the ensemble for different regions of the attractor. Some EnSRFs that use random rotations have been developed to overcome this issue; these formulations are analyzed and their advantages and disadvantages with respect to common EnSRFs are discussed. The third and last part contains the implementation of the Robert-Asselin-Williams (RAW) filter in an atmospheric model. The RAW filter is an improvement to the widely popular Robert-Asselin filter that successfully suppresses spurious computational waves while avoiding any distortion

  5. Evaluation Using Sequential Trials Methods.

    Science.gov (United States)

    Cohen, Mark E.; Ralls, Stephen A.

    1986-01-01

    Although dental school faculty as well as practitioners are interested in evaluating products and procedures used in clinical practice, research design and statistical analysis can sometimes pose problems. Sequential trials methods provide an analytical structure that is both easy to use and statistically valid. (Author/MLW)

  6. Attack Trees with Sequential Conjunction

    NARCIS (Netherlands)

    Jhawar, Ravi; Kordy, Barbara; Mauw, Sjouke; Radomirović, Sasa; Trujillo-Rasua, Rolando

    2015-01-01

    We provide the first formal foundation of SAND attack trees which are a popular extension of the well-known attack trees. The SAND at- tack tree formalism increases the expressivity of attack trees by intro- ducing the sequential conjunctive operator SAND. This operator enables the modeling of

  7. Space- and time-resolved diagnostic of line emission from the separatrix region in JET X-point plasmas

    International Nuclear Information System (INIS)

    Chabert, P.; Breton, C.; DeMichelis, C.; Mattioli, M.; Ramette, J.; Saoutic, B.; Denne, B.; Giannella, R.; Gottardi, N.; Magyar, G.

    1989-01-01

    The SPEX GISMO VUV spectrometer installed on JET has appeared to be appropriate to study the impurities radiation during X-point operation. Preliminary results have been obtained with 2 of the 3 spectrometers. They concern mainly the light impurities emission, CIII, O VI in the vicinity of the X-point during the transition from L to H mode. The results are reported for both single X and double X discharges and future prospects are assessed. (author) 4 refs., 6 figs

  8. Change Points in the Population Trends of Aerial-Insectivorous Birds in North America: Synchronized in Time across Species and Regions.

    Directory of Open Access Journals (Sweden)

    Adam C Smith

    Full Text Available North American populations of aerial insectivorous birds are in steep decline. Aerial insectivores (AI are a group of bird species that feed almost exclusively on insects in flight, and include swallows, swifts, nightjars, and flycatchers. The causes of the declines are not well understood. Indeed, it is not clear when the declines began, or whether the declines are shared across all species in the group (e.g., caused by changes in flying insect populations or specific to each species (e.g., caused by changes in species' breeding habitat. A recent study suggested that population trends of aerial insectivores changed for the worse in the 1980s. If there was such a change point in trends of the group, understanding its timing and geographic pattern could help identify potential causes of the decline. We used a hierarchical Bayesian, penalized regression spline, change point model to estimate group-level change points in the trends of 22 species of AI, across 153 geographic strata of North America. We found evidence for group-level change points in 85% of the strata. Change points for flycatchers (FC were distinct from those for swallows, swifts and nightjars (SSN across North America, except in the Northeast, where all AI shared the same group-level change points. During the 1980s, there was a negative change point across most of North America, in the trends of SSN. For FC, the group-level change points were more geographically variable, and in many regions there were two: a positive change point followed by a negative change point. This group-level synchrony in AI population trends is likely evidence of a response to a common environmental factor(s with similar effects on many species across broad spatial extents. The timing and geographic patterns of the change points that we identify here should provide a spring-board for research into the causes behind aerial insectivore declines.

  9. Variation in type and frequency of diagnostic imaging during trauma care across multiple time points by patient insurance type

    International Nuclear Information System (INIS)

    Bell, Nathaniel; Repáraz, Laura; Fry, William R.; Smith, R. Stephen; Luis, Alejandro

    2016-01-01

    Research has shown that uninsured patients receive fewer radiographic studies during trauma care, but less is known as to whether differences in care are present among other insurance groups or across different time points during hospitalization. Our objective was to examine the number of radiographic studies administered to a cohort of trauma patients over the entire hospital stay as well as during the first 24-hours of care. Patient data were obtained from an American College of Surgeons (ACS) verified Level I Trauma Center between January 1, 2011 and December 31, 2012. We used negative binomial regression to construct relative risk (RR) ratios for type and frequency of radiographic imaging received among persons with Medicare, Medicaid, no insurance, or government insurance plans in reference to those with commercial indemnity plans. The analysis was adjusted for patient age, sex, race/ethnicity, injury severity score, injury mechanism, comorbidities, complications, hospital length of stay, and Intensive Care Unit (ICU) admission. A total of 3621 records from surviving patients age > =18 years were assessed. After adjustment for potential confounders, the expected number of radiographic studies decreased by 15 % among Medicare recipients (RR 0.85, 95 % CI 0.78–0.93), 11 % among Medicaid recipients (0.89, 0.81–0.99), 10 % among the uninsured (0.90, 0.85–0.96) and 19 % among government insurance groups (0.81, 0.72–0.90), compared with the reference group. This disparity was observed during the first 24-hours of care among patients with Medicare (0.78, 0.71–0.86) and government insurance plans (0.83, 0.74–0.94). Overall, there were no differences in the number of radiographic studies among the uninsured or among Medicaid patients during the first 24-hours of care compared with the reference group, but differences were observed among the uninsured in a sub-analysis of severely injured patients (ISS > 15). Both uninsured and insured patients treated at a

  10. Computing sequential equilibria for two-player games

    DEFF Research Database (Denmark)

    Miltersen, Peter Bro

    2006-01-01

    Koller, Megiddo and von Stengel showed how to efficiently compute minimax strategies for two-player extensive-form zero-sum games with imperfect information but perfect recall using linear programming and avoiding conversion to normal form. Their algorithm has been used by AI researchers...... for constructing prescriptive strategies for concrete, often fairly large games. Koller and Pfeffer pointed out that the strategies obtained by the algorithm are not necessarily sequentially rational and that this deficiency is often problematic for the practical applications. We show how to remove this deficiency...... by modifying the linear programs constructed by Koller, Megiddo and von Stengel so that pairs of strategies forming a sequential equilibrium are computed. In particular, we show that a sequential equilibrium for a two-player zero-sum game with imperfect information but perfect recall can be found in polynomial...

  11. Peripheral tuberculous lymphadenitis masquerading as metastatic gastric carcinoma on F 18 FDG dual time point PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su Kon; Shin, Jeong Eun; Lee, Jai Hyuen [Dankook Univ. College of Medicine, Cheonan (Korea, Republic of)

    2012-12-15

    A 59 year old woman was hospitalized with weight loss, anorexia, and low grade fever for 2 weeks. she had under gone a total gastrectomy followed by adjuvant chemotherapy 10 years prior due to advanced gastric cancer to evaluate recurrence, fluorine 19 fluorodeoxyglucose (FDG) dual time point positron emission tomography/computed tomography (DTPP) was conducted with a gemini GXL 6 PET/CT system (Philips, Hamburg, Germany). FDG DTPP was performed twice, with an early scan 60 min after FDG injection and a delayed scan 150min after FDG injection. The early scan showed that multiple hypermetabolic lesions were located along left supraclavicular, mediastinal (1R, 2R, 3, 4R and 7) and left paraaortic (retroperitoneal) nodal stations. The delayed scan showed that all the above mentioned lesions revealed a more increased maximal standard uptake value (SUVmax) than was detected in the early scan. both scans did not show intrapulmonary lesion. For example, the left supraclavicular lymph node, 2R and retroperitoneal lymph node were observed with early and delayed SUV maxes of 4.5/7.6/3.6 and 6.7/7.7/3.6 and 6.7/10.7/4.4, respectively. Tom confirm diagnosis and establish a treatment plan, a mediastinoscopic biopsy of one of the mediastinal lymph nodes (4R) was subsequently performed and tuberculosis was ultimately diagnosed. Then, the patient started an antituberculosis treatment instead of antichemotherapy. A follow up FDG PET/CT performed 12 months later showed disappeared FDG uptake and significant decreased change of multiple peripheral tuberculous lymphadenitis. Whole body FDG PET/CT has widespread use in diagnosing and staging variable malignancies, and plays an important role in detection of gastric cancer recurrence. However, FDG is not cancer specific and some inflammatory diseases have shown higher FDG uptake on PET imaging. Infection, inflammation, and granulomatosis are also known to cause false positive FDG PET scans because activated inflammatory cells show

  12. Effects of Point Count Duration, Time-of-Day, and Aural Stimuli on Detectability of Migratory and Resident Bird Species in Quintana Roo, Mexico

    Science.gov (United States)

    James F. Lynch

    1995-01-01

    Effects of count duration, time-of-day, and aural stimuli were studied in a series of unlimited-radius point counts conducted during winter in Quintana Roo, Mexico. The rate at which new species were detected was approximately three times higher during the first 5 minutes of each 15- minute count than in the final 5 minutes. The number of individuals and species...

  13. Improved Murine Blastocyst Quality and Development in a Single Culture Medium Compared to Sequential Culture Media.

    Science.gov (United States)

    Hennings, Justin M; Zimmer, Randall L; Nabli, Henda; Davis, J Wade; Sutovsky, Peter; Sutovsky, Miriam; Sharpe-Timms, Kathy L

    2016-03-01

    Validate single versus sequential culture media for murine embryo development. Prospective laboratory experiment. Assisted Reproduction Laboratory. Murine embryos. Thawed murine zygotes cultured for 3 or 5 days (d3 or d5) in single or sequential embryo culture media developed for human in vitro fertilization. On d3, zygotes developing to the 8 cell (8C) stage or greater were quantified using 4',6-diamidino-2-phenylindole (DAPI), and quality was assessed by morphological analysis. On d5, the number of embryos reaching the blastocyst stage was counted. DAPI was used to quantify total nuclei and inner cell mass nuclei. Localization of ubiquitin C-terminal hydrolase L1 (UCHL1) and ubiquitin C-terminal hydrolase L3 (UCHL3) was reference points for evaluating cell quality. Comparing outcomes in single versus to sequential media, the odds of embryos developing to the 8C stage on d3 were 2.34 time greater (P = .06). On d5, more embryos reached the blastocyst stage (P = culture. Human embryo studies are needed. © The Author(s) 2015.

  14. A simple method for regional cerebral blood flow measurement by one-point arterial blood sampling and 123I-IMP microsphere model (part 2). A study of time correction of one-point blood sample count

    International Nuclear Information System (INIS)

    Masuda, Yasuhiko; Makino, Kenichi; Gotoh, Satoshi

    1999-01-01

    In our previous paper regarding determination of the regional cerebral blood flow (rCBF) using the 123 I-IMP microsphere model, we reported that the accuracy of determination of the integrated value of the input function from one-point arterial blood sampling can be increased by performing correction using the 5 min: 29 min ratio for the whole-brain count. However, failure to carry out the arterial blood collection at exactly 5 minutes after 123 I-IMP injection causes errors with this method, and there is thus a time limitation. We have now revised out method so that the one-point arterial blood sampling can be performed at any time during the interval between 5 minutes and 20 minutes after 123 I-IMP injection, with addition of a correction step for the sampling time. This revised method permits more accurate estimation of the integral of the input functions. This method was then applied to 174 experimental subjects: one-point blood samples collected at random times between 5 and 20 minutes, and the estimated values for the continuous arterial octanol extraction count (COC) were determined. The mean error rate between the COC and the actual measured continuous arterial octanol extraction count (OC) was 3.6%, and the standard deviation was 12.7%. Accordingly, in 70% of the cases, the rCBF was able to be estimated within an error rate of 13%, while estimation was possible in 95% of the cases within an error rate of 25%. This improved method is a simple technique for determination of the rCBF by 123 I-IMP microsphere model and one-point arterial blood sampling which no longer shows a time limitation and does not require any octanol extraction step. (author)

  15. Identification of a time-varying point source in a system of two coupled linear diffusion-advection- reaction equations: application to surface water pollution

    International Nuclear Information System (INIS)

    Hamdi, Adel

    2009-01-01

    This paper deals with the identification of a point source (localization of its position and recovering the history of its time-varying intensity function) that constitutes the right-hand side of the first equation in a system of two coupled 1D linear transport equations. Assuming that the source intensity function vanishes before reaching the final control time, we prove the identifiability of the sought point source from recording the state relative to the second coupled transport equation at two observation points framing the source region. Note that at least one of the two observation points should be strategic. We establish an identification method that uses these records to identify the source position as the root of a continuous and strictly monotonic function. Whereas the source intensity function is recovered using a recursive formula without any need of an iterative process. Some numerical experiments on a variant of the surface water pollution BOD–OD coupled model are presented

  16. Twin Positive Solutions of a Nonlinear m-Point Boundary Value Problem for Third-Order p-Laplacian Dynamic Equations on Time Scales

    Directory of Open Access Journals (Sweden)

    Wei Han

    2008-01-01

    Full Text Available Several existence theorems of twin positive solutions are established for a nonlinear m-point boundary value problem of third-order p-Laplacian dynamic equations on time scales by using a fixed point theorem. We present two theorems and four corollaries which generalize the results of related literature. As an application, an example to demonstrate our results is given. The obtained conditions are different from some known results.

  17. TH-AB-202-08: A Robust Real-Time Surface Reconstruction Method On Point Clouds Captured From a 3D Surface Photogrammetry System

    International Nuclear Information System (INIS)

    Liu, W; Sawant, A; Ruan, D

    2016-01-01

    Purpose: Surface photogrammetry (e.g. VisionRT, C-Rad) provides a noninvasive way to obtain high-frequency measurement for patient motion monitoring in radiotherapy. This work aims to develop a real-time surface reconstruction method on the acquired point clouds, whose acquisitions are subject to noise and missing measurements. In contrast to existing surface reconstruction methods that are usually computationally expensive, the proposed method reconstructs continuous surfaces with comparable accuracy in real-time. Methods: The key idea in our method is to solve and propagate a sparse linear relationship from the point cloud (measurement) manifold to the surface (reconstruction) manifold, taking advantage of the similarity in local geometric topology in both manifolds. With consistent point cloud acquisition, we propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, building the point correspondences by the iterative closest point (ICP) method. To accommodate changing noise levels and/or presence of inconsistent occlusions, we further propose a modified sparse regression (MSR) model to account for the large and sparse error built by ICP, with a Laplacian prior. We evaluated our method on both clinical acquired point clouds under consistent conditions and simulated point clouds with inconsistent occlusions. The reconstruction accuracy was evaluated w.r.t. root-mean-squared-error, by comparing the reconstructed surfaces against those from the variational reconstruction method. Results: On clinical point clouds, both the SR and MSR models achieved sub-millimeter accuracy, with mean reconstruction time reduced from 82.23 seconds to 0.52 seconds and 0.94 seconds, respectively. On simulated point cloud with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent performance despite the introduced occlusions. Conclusion: We have developed a real-time

  18. Job Demands, Burnout, and Teamwork in Healthcare Professionals Working in a General Hospital that Was Analysed At Two Points in Time.

    Science.gov (United States)

    Mijakoski, Dragan; Karadzhinska-Bislimovska, Jovanka; Stoleski, Sasho; Minov, Jordan; Atanasovska, Aneta; Bihorac, Elida

    2018-04-15

    The purpose of the paper was to assess job demands, burnout, and teamwork in healthcare professionals (HPs) working in a general hospital that was analysed at two points in time with a time lag of three years. Time 1 respondents (N = 325) were HPs who participated during the first wave of data collection (2011). Time 2 respondents (N = 197) were HPs from the same hospital who responded at Time 2 (2014). Job demands, burnout, and teamwork were measured with Hospital Experience Scale, Maslach Burnout Inventory, and Hospital Survey on Patient Safety Culture, respectively. Significantly higher scores of emotional exhaustion (21.03 vs. 15.37, t = 5.1, p job demands were found at Time 2. Teamwork levels were similar at both points in time (Time 1 = 3.84 vs. Time 2 = 3.84, t = 0.043, p = 0.97). Actual longitudinal study revealed significantly higher mean values of emotional exhaustion and depersonalization in 2014 that could be explained by significantly increased job demands between analysed points in time.

  19. Effects of Varying Epoch Lengths, Wear Time Algorithms, and Activity Cut-Points on Estimates of Child Sedentary Behavior and Physical Activity from Accelerometer Data.

    Science.gov (United States)

    Banda, Jorge A; Haydel, K Farish; Davila, Tania; Desai, Manisha; Bryson, Susan; Haskell, William L; Matheson, Donna; Robinson, Thomas N

    2016-01-01

    To examine the effects of accelerometer epoch lengths, wear time (WT) algorithms, and activity cut-points on estimates of WT, sedentary behavior (SB), and physical activity (PA). 268 7-11 year-olds with BMI ≥ 85th percentile for age and sex wore accelerometers on their right hips for 4-7 days. Data were processed and analyzed at epoch lengths of 1-, 5-, 10-, 15-, 30-, and 60-seconds. For each epoch length, WT minutes/day was determined using three common WT algorithms, and minutes/day and percent time spent in SB, light (LPA), moderate (MPA), and vigorous (VPA) PA were determined using five common activity cut-points. ANOVA tested differences in WT, SB, LPA, MPA, VPA, and MVPA when using the different epoch lengths, WT algorithms, and activity cut-points. WT minutes/day varied significantly by epoch length when using the NHANES WT algorithm (p algorithms. Minutes/day and percent time spent in SB, LPA, MPA, VPA, and MVPA varied significantly by epoch length for all sets of activity cut-points tested with all three WT algorithms (all p algorithms (all p algorithms and activity cut-point definitions to match different epoch lengths may introduce significant errors. Estimates of SB and PA from studies that process and analyze data using different epoch lengths, WT algorithms, and/or activity cut-points are not comparable, potentially leading to very different results, interpretations, and conclusions, misleading research and public policy.

  20. Robustness of the Sequential Lineup Advantage

    Science.gov (United States)

    Gronlund, Scott D.; Carlson, Curt A.; Dailey, Sarah B.; Goodsell, Charles A.

    2009-01-01

    A growing movement in the United States and around the world involves promoting the advantages of conducting an eyewitness lineup in a sequential manner. We conducted a large study (N = 2,529) that included 24 comparisons of sequential versus simultaneous lineups. A liberal statistical criterion revealed only 2 significant sequential lineup…

  1. Sequential Probability Ration Tests : Conservative and Robust

    NARCIS (Netherlands)

    Kleijnen, J.P.C.; Shi, Wen

    2017-01-01

    In practice, most computers generate simulation outputs sequentially, so it is attractive to analyze these outputs through sequential statistical methods such as sequential probability ratio tests (SPRTs). We investigate several SPRTs for choosing between two hypothesized values for the mean output

  2. Random sequential adsorption of cubes

    Science.gov (United States)

    Cieśla, Michał; Kubala, Piotr

    2018-01-01

    Random packings built of cubes are studied numerically using a random sequential adsorption algorithm. To compare the obtained results with previous reports, three different models of cube orientation sampling were used. Also, three different cube-cube intersection algorithms were tested to find the most efficient one. The study focuses on the mean saturated packing fraction as well as kinetics of packing growth. Microstructural properties of packings were analyzed using density autocorrelation function.

  3. Job Demands, Burnout, and Teamwork in Healthcare Professionals Working in a General Hospital that Was Analysed At Two Points in Time

    Science.gov (United States)

    Mijakoski, Dragan; Karadzhinska-Bislimovska, Jovanka; Stoleski, Sasho; Minov, Jordan; Atanasovska, Aneta; Bihorac, Elida

    2018-01-01

    AIM: The purpose of the paper was to assess job demands, burnout, and teamwork in healthcare professionals (HPs) working in a general hospital that was analysed at two points in time with a time lag of three years. METHODS: Time 1 respondents (N = 325) were HPs who participated during the first wave of data collection (2011). Time 2 respondents (N = 197) were HPs from the same hospital who responded at Time 2 (2014). Job demands, burnout, and teamwork were measured with Hospital Experience Scale, Maslach Burnout Inventory, and Hospital Survey on Patient Safety Culture, respectively. RESULTS: Significantly higher scores of emotional exhaustion (21.03 vs. 15.37, t = 5.1, p Teamwork levels were similar at both points in time (Time 1 = 3.84 vs. Time 2 = 3.84, t = 0.043, p = 0.97). CONCLUSION: Actual longitudinal study revealed significantly higher mean values of emotional exhaustion and depersonalization in 2014 that could be explained by significantly increased job demands between analysed points in time. PMID:29731948

  4. On the origin of reproducible sequential activity in neural circuits

    Science.gov (United States)

    Afraimovich, V. S.; Zhigulin, V. P.; Rabinovich, M. I.

    2004-12-01

    Robustness and reproducibility of sequential spatio-temporal responses is an essential feature of many neural circuits in sensory and motor systems of animals. The most common mathematical images of dynamical regimes in neural systems are fixed points, limit cycles, chaotic attractors, and continuous attractors (attractive manifolds of neutrally stable fixed points). These are not suitable for the description of reproducible transient sequential neural dynamics. In this paper we present the concept of a stable heteroclinic sequence (SHS), which is not an attractor. SHS opens the way for understanding and modeling of transient sequential activity in neural circuits. We show that this new mathematical object can be used to describe robust and reproducible sequential neural dynamics. Using the framework of a generalized high-dimensional Lotka-Volterra model, that describes the dynamics of firing rates in an inhibitory network, we present analytical results on the existence of the SHS in the phase space of the network. With the help of numerical simulations we confirm its robustness in presence of noise in spite of the transient nature of the corresponding trajectories. Finally, by referring to several recent neurobiological experiments, we discuss possible applications of this new concept to several problems in neuroscience.

  5. Green Grape Detection and Picking-Point Calculation in a Night-Time Natural Environment Using a Charge-Coupled Device (CCD Vision Sensor with Artificial Illumination

    Directory of Open Access Journals (Sweden)

    Juntao Xiong

    2018-03-01

    Full Text Available Night-time fruit-picking technology is important to picking robots. This paper proposes a method of night-time detection and picking-point positioning for green grape-picking robots to solve the difficult problem of green grape detection and picking in night-time conditions with artificial lighting systems. Taking a representative green grape named Centennial Seedless as the research object, daytime and night-time grape images were captured by a custom-designed visual system. Detection was conducted employing the following steps: (1 The RGB (red, green and blue. Color model was determined for night-time green grape detection through analysis of color features of grape images under daytime natural light and night-time artificial lighting. The R component of the RGB color model was rotated and the image resolution was compressed; (2 The improved Chan–Vese (C–V level set model and morphological processing method were used to remove the background of the image, leaving out the grape fruit; (3 Based on the character of grape vertical suspension, combining the principle of the minimum circumscribed rectangle of fruit and the Hough straight line detection method, straight-line fitting for the fruit stem was conducted and the picking point was calculated using the stem with an angle of fitting line and vertical line less than 15°. The visual detection experiment results showed that the accuracy of grape fruit detection was 91.67% and the average running time of the proposed algorithm was 0.46 s. The picking-point calculation experiment results showed that the highest accuracy for the picking-point calculation was 92.5%, while the lowest was 80%. The results demonstrate that the proposed method of night-time green grape detection and picking-point calculation can provide technical support to the grape-picking robots.

  6. The impact of scheduling on service reliability : Trip-time determination and holding points in long-headway services

    NARCIS (Netherlands)

    Van Oort, N.; Boterman, J.W.; Van Nes, R.

    2012-01-01

    This paper presents research on optimizing service reliability of longheadway services in urban public transport. Setting the driving time, and thus the departure time at stops, is an important decision when optimizing reliability in urban public transport. The choice of the percentile out of

  7. Is it time to include point-of-care ultrasound in general surgery training? A review to stimulate discussion.

    Science.gov (United States)

    Mollenkopf, Maximilian; Tait, Noel

    2013-12-01

    Point-of-care ultrasound scanning or POCUS is a focused ultrasound (US) scan, performed by non-imaging clinicians during physical examination, an invasive procedure or surgery. As this technology becomes cheaper, smaller and easier to use, its scope for use by surgeons grows, a trend that may generate a gap between use and training. Opportunities for enhanced general surgery skill sets may be reduced unless consideration is given to inclusion of POCUS in general surgery training. To stimulate discussion regarding inclusion of POCUS in the general surgery curriculum; to resource this discussion with an overview of current trends and issues around POCUS; and to discuss concerns and controversies that may arise if POCUS was adopted into general surgery training. A literature search was performed using PUBMED, MEDLINE, Google and Google Scholar, using the terms 'ultrasound', 'point-of-care-ultrasound', 'bedside ultrasound', 'portable ultrasound' and 'hand-held ultrasound'. Literature, references and non-literature resources found were reviewed for relevance to US education in general surgery. Increasingly, medical students are graduating with basic POCUS skills. Specialty-specific uses of POCUS are proliferating. Training and assessment resources are not keeping up, in accessibility or standardization. A learned surgical college led training and accreditation process would require aligned education in anatomy and US technology and collaboration with the specialist imaging community to ensure appropriate standards are clarified and met. Research is also required into how general surgery trainees can best achieve and maintain POCUS competence. © 2013 Royal Australasian College of Surgeons.

  8. Application of the nonlinear time series prediction method of genetic algorithm for forecasting surface wind of point station in the South China Sea with scatterometer observations

    International Nuclear Information System (INIS)

    Zhong Jian; Dong Gang; Sun Yimei; Zhang Zhaoyang; Wu Yuqin

    2016-01-01

    The present work reports the development of nonlinear time series prediction method of genetic algorithm (GA) with singular spectrum analysis (SSA) for forecasting the surface wind of a point station in the South China Sea (SCS) with scatterometer observations. Before the nonlinear technique GA is used for forecasting the time series of surface wind, the SSA is applied to reduce the noise. The surface wind speed and surface wind components from scatterometer observations at three locations in the SCS have been used to develop and test the technique. The predictions have been compared with persistence forecasts in terms of root mean square error. The predicted surface wind with GA and SSA made up to four days (longer for some point station) in advance have been found to be significantly superior to those made by persistence model. This method can serve as a cost-effective alternate prediction technique for forecasting surface wind of a point station in the SCS basin. (paper)

  9. Impact of sequential proton density fat fraction for quantification of hepatic steatosis in nonalcoholic fatty liver disease.

    Science.gov (United States)

    Idilman, Ilkay S; Keskin, Onur; Elhan, Atilla Halil; Idilman, Ramazan; Karcaaltincaba, Musturay

    2014-05-01

    To determine the utility of sequential MRI-estimated proton density fat fraction (MRI-PDFF) for quantification of the longitudinal changes in liver fat content in individuals with nonalcoholic fatty liver disease (NAFLD). A total of 18 consecutive individuals (M/F: 10/8, mean age: 47.7±9.8 years) diagnosed with NAFLD, who underwent sequential PDFF calculations for the quantification of hepatic steatosis at two different time points, were included in the study. All patients underwent T1-independent volumetric multi-echo gradient-echo imaging with T2* correction and spectral fat modeling. A close correlation for quantification of hepatic steatosis between the initial MRI-PDFF and liver biopsy was observed (rs=0.758, phepatic steatosis. The changes in serum ALT levels significantly reflected changes in MRI-PDFF in patients with NAFLD.

  10. Usefulness of Time-Point Serum Cortisol and ACTH Measurements for the Adjustment of Glucocorticoid Replacement in Adrenal Insufficiency.

    Science.gov (United States)

    Rousseau, Elise; Joubert, Michael; Trzepla, Géraldine; Parienti, Jean Jacques; Freret, Thomas; Vanthygem, Marie Christine; Desailloud, Rachel; Lefebvre, Hervé; Coquerel, Antoine; Reznik, Yves

    2015-01-01

    Adjustment of daily hydrocortisone dose on clinical criteria lacks sensitivity for fine tuning. Long term hydrocortisone (HC) over-replacement may lead to increased morbidity and mortality in patients with adrenal insufficiency (AI). Biochemical criteria may help detecting over- or under-replacement but have been poorly evaluated. Multicenter, institutional, pharmacokinetic study on ACTH and cortisol plasma profiles during HC replacement in 27 AI patients compared to 29 matched controls. All AI patients were administered HC thrice daily at doses of 6, 10 and 14 mg/m2/d. Blood samples were drawn hourly from 0800h to 1900h. The main outcome measures were: i) plasma peak cortisol and cortisol area under the curve (AUC) in AI patients compared to controls, ii) correlations between cortisol AUC vs single-point cortisol or ACTH decrease from baseline (ΔACTH) and iii) the predictive value of the two latters for obtaining AI patients' cortisol AUC in the control range. Cortisol peaks were observed 1h after each HC intake and a dose response was demonstrated for cortisol peak and cortisol AUC. The comparison of AI patients' cortisol AUC to controls showed that 81.5% AI patients receiving 6mg/m2/d were adequately replaced, whereas most patients receiving higher doses were over-replaced. The correlation coefficient between 1000h/1400h cortisol concentrations and 0800-1900h cortisol AUC were 0.93/0.88 respectively, whereas the 0800-1200h ΔACTH fairly correlated with 0800-1900h cortisol AUC (R = 0.57). ROC curve analysis indicated that the 1000h and 1400h cortisol concentrations best predicted over-replacement. Patients receiving a 6mg/m2 hydrocortisone daily dose exhibited the most physiological daytime cortisol profile. Single point plasma cortisol correlated with daytime cortisol AUC in AI patients. Although hydrocortisone dose should be currently determined on clinical grounds, our data suggest that single point plasma cortisol may be an adjunct for further hydrocortisone

  11. The Dynamics of Smoking-Related Disturbed Methylation: A Two Time-Point Study of Methylation Change in Smokers, Non-Smokers and Former Smokers

    Science.gov (United States)

    BACKGROUND: The evidence for epigenome-wide associations between smoking and DNA methylation continues to grow through cross-sectional studies. However, few large­ scale investigations have explored the associations using observations for individuals at multiple time-points. ...

  12. MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle?

    Energy Technology Data Exchange (ETDEWEB)

    Jurencak, Tomas; Turek, Jakub; Nijssen, Estelle C. [Maastricht University Medical Center, Department of Radiology, P. Debyelaan 25, P.O. Box 5800, AZ, Maastricht (Netherlands); Kietselaer, Bastiaan L.J.H. [Maastricht University Medical Center, Department of Radiology, P. Debyelaan 25, P.O. Box 5800, AZ, Maastricht (Netherlands); Maastricht University Medical Center, CARIM School for Cardiovascular Diseases, Maastricht (Netherlands); Maastricht University Medical Center, Department of Cardiology, Maastricht (Netherlands); Mihl, Casper; Kok, Madeleine; Wildberger, Joachim E.; Das, Marco [Maastricht University Medical Center, Department of Radiology, P. Debyelaan 25, P.O. Box 5800, AZ, Maastricht (Netherlands); Maastricht University Medical Center, CARIM School for Cardiovascular Diseases, Maastricht (Netherlands); Ommen, Vincent G.V.A. van [Maastricht University Medical Center, Department of Cardiology, Maastricht (Netherlands); Garsse, Leen A.F.M. van [Maastricht University Medical Center, Department of Cardiothoracic Surgery, Maastricht (Netherlands)

    2015-07-15

    To determine the optimal imaging time point for transcatheter aortic valve implantation (TAVI) therapy planning by comprehensive evaluation of the aortic root. Multidetector-row CT (MDCT) examination with retrospective ECG gating was retrospectively performed in 64 consecutive patients referred for pre-TAVI assessment. Eighteen different parameters of the aortic root were evaluated at 11 different time points in the cardiac cycle. Time points at which maximal (or minimal) sizes were determined, and dimension differences to other time points were evaluated. Theoretical prosthesis sizing based on different measurements was compared. Largest dimensions were found between 10 and 20 % of the cardiac cycle for annular short diameter (10 %); mean diameter (10 %); effective diameter and circumference-derived diameter (20 %); distance from the annulus to right coronary artery ostium (10 %); aortic root at the left coronary artery level (20 %); aortic root at the widest portion of coronary sinuses (20 %); and right leaflet length (20 %). Prosthesis size selection differed depending on the chosen measurements in 25-75 % of cases. Significant changes in anatomical structures of the aortic root during the cardiac cycle are crucial for TAVI planning. Imaging in systole is mandatory to obtain maximal dimensions. (orig.)

  13. Lab-in-a-tube: Real-time molecular point-of-care diagnostics for influenza A and B using the cobas(R) Liat(R) system

    NARCIS (Netherlands)

    Melchers, W.J.G.; Kuijpers, J; Sickler, J.J.; Rahamat-Langendoen, J.C.

    2017-01-01

    Rapid diagnosis of influenza A and B is important for direct treatment decisions in patient care and for the reduction of in-hospital transmissions. The new real-time PCR based molecular point-of-care (POC) assay, the cobas(R) Influenza A/B test on the cobas(R) Liat(R) System (cobas(R) Liat(R)

  14. How Well Does High School Grade Point Average Predict College Performance by Student Urbanicity and Timing of College Entry? REL 2017-250

    Science.gov (United States)

    Hodara, Michelle; Lewis, Karyn

    2017-01-01

    This report is a companion to a study that found that high school grade point average was a stronger predictor of performance in college-level English and math than were standardized exam scores among first-time students at the University of Alaska who enrolled directly in college-level courses. This report examines how well high school grade…

  15. Comparison of Sequential and Variational Data Assimilation

    Science.gov (United States)

    Alvarado Montero, Rodolfo; Schwanenberg, Dirk; Weerts, Albrecht

    2017-04-01

    Data assimilation is a valuable tool to improve model state estimates by combining measured observations with model simulations. It has recently gained significant attention due to its potential in using remote sensing products to improve operational hydrological forecasts and for reanalysis purposes. This has been supported by the application of sequential techniques such as the Ensemble Kalman Filter which require no additional features within the modeling process, i.e. it can use arbitrary black-box models. Alternatively, variational techniques rely on optimization algorithms to minimize a pre-defined objective function. This function describes the trade-off between the amount of noise introduced into the system and the mismatch between simulated and observed variables. While sequential techniques have been commonly applied to hydrological processes, variational techniques are seldom used. In our believe, this is mainly attributed to the required computation of first order sensitivities by algorithmic differentiation techniques and related model enhancements, but also to lack of comparison between both techniques. We contribute to filling this gap and present the results from the assimilation of streamflow data in two basins located in Germany and Canada. The assimilation introduces noise to precipitation and temperature to produce better initial estimates of an HBV model. The results are computed for a hindcast period and assessed using lead time performance metrics. The study concludes with a discussion of the main features of each technique and their advantages/disadvantages in hydrological applications.

  16. Point Climat no. 13 'Will there still be a market price for CERs and ERUs in two years time?'

    International Nuclear Information System (INIS)

    Bellassen, Valentin; Stephan, Nicolas; Leguet, Benoit

    2012-01-01

    Among the publications of CDC Climat Research, 'Climate Briefs' presents, in a few pages, hot topics in climate change policy. This issue addresses the following points: Medium-term (i.e. pre-2015) demand for credits from the EU ETS and secondary sources of demand appears to be limited to 1.6 billion tCO 2 e. The supply of Kyoto credits is relatively predictable, and will cover demand between now and 2013-2014 according to our base-case scenario. Our view is that the demand-supply equilibrium will lead to a de-correlation between the price of Kyoto credits and the EUA price, and may lead to a price for Kyoto credits that is very low, or almost nil. Unless CER and ERU demand-side policies are modified, we do not foresee any rebound in CER and ERU prices beyond the current year

  17. Transition times between the extremum points of the current–voltage characteristic of a resonant tunneling diode with hysteresis

    Energy Technology Data Exchange (ETDEWEB)

    Grishakov, K. S., E-mail: ksgrishakov@yahoo.com; Elesin, V. F. [National Research Nuclear University “MEPhI” (Russian Federation)

    2016-08-15

    A numerical solution to the problem of transient processes in a resonant tunneling diode featuring a current–voltage characteristic with hysteresis is found for the first time in the context of a coherent model (based on the coupled Schrödinger and Poisson equations) taking into account the Fermi distribution of electrons. The transitions from the high-current to the low-current state and vice versa, which result from the existence of hysteresis and are of great practical importance for ultrafast switches based on resonant tunneling diodes, are studied in detail. It is shown that the transition times for such processes initiated by the application of a small voltage can significantly exceed the characteristic time ℏ/Γ (where G is the width of the resonance level). It is established for the first time that the transition time can be reduced and made as short as the characteristic time ℏ/Γ by applying a sufficiently high voltage. For the parameters of the resonant-tunnelingdiode structure considered in this study, the required voltage is about 0.01 V.

  18. Impact of dual-time-point F-18 FDG PET/CT in the assessment of pleural effusion in patients with non-small-cell lung cancer.

    Science.gov (United States)

    Alkhawaldeh, Khaled; Biersack, Hans-J; Henke, Anna; Ezziddin, Samer

    2011-06-01

    The aim of this study was to assess the utility of dual-time-point F-18 fluorodeoxyglucose positron emission tomography (F-18 FDG PET) in differentiating benign from malignant pleural disease, in patients with non-small-cell lung cancer. A total of 61 patients with non-small-cell lung cancer and pleural effusion were included in this retrospective study. All patients had whole-body FDG PET/CT imaging at 60 ± 10 minutes post-FDG injection, whereas 31 patients had second-time delayed imaging repeated at 90 ± 10 minutes for the chest. Maximum standardized uptake values (SUV(max)) and the average percent change in SUV(max) (%SUV) between time point 1 and time point 2 were calculated. Malignancy was defined using the following criteria: (1) visual assessment using 3-points grading scale; (2) SUV(max) ≥2.4; (3) %SUV ≥ +9; and (4) SUV(max) ≥2.4 and/or %SUV ≥ +9. Analysis of variance test and receiver operating characteristic analysis were used in statistical analysis. P < 0.05 was considered significant. Follow-up revealed 29 patient with malignant pleural disease and 31 patients with benign pleural effusion. The average SUV(max) in malignant effusions was 6.5 ± 4 versus 2.2 ± 0.9 in benign effusions (P < 0.0001). The average %SUV in malignant effusions was +13 ± 10 versus -8 ± 11 in benign effusions (P < 0.0004). Sensitivity, specificity, and accuracy for the 5 criteria were as follows: (1) 86%, 72%, and 79%; (2) 93%, 72%, and 82%; (3) 67%, 94%, and 81%; (4) 100%, 94%, and 97%. Dual-time-point F-18 FDG PET can improve the diagnostic accuracy in differentiating benign from malignant pleural disease, with high sensitivity and good specificity.

  19. Computing travel time when the exact address is unknown: a comparison of point and polygon ZIP code approximation methods.

    Science.gov (United States)

    Berke, Ethan M; Shi, Xun

    2009-04-29

    Travel time is an important metric of geographic access to health care. We compared strategies of estimating travel times when only subject ZIP code data were available. Using simulated data from New Hampshire and Arizona, we estimated travel times to nearest cancer centers by using: 1) geometric centroid of ZIP code polygons as origins, 2) population centroids as origin, 3) service area rings around each cancer center, assigning subjects to rings by assuming they are evenly distributed within their ZIP code, 4) service area rings around each center, assuming the subjects follow the population distribution within the ZIP code. We used travel times based on street addresses as true values to validate estimates. Population-based methods have smaller errors than geometry-based methods. Within categories (geometry or population), centroid and service area methods have similar errors. Errors are smaller in urban areas than in rural areas. Population-based methods are superior to the geometry-based methods, with the population centroid method appearing to be the best choice for estimating travel time. Estimates in rural areas are less reliable.

  20. The Avalanche Hypothesis and Compression of Morbidity: Testing Assumptions through Cohort-Sequential Analysis.

    Directory of Open Access Journals (Sweden)

    Jordan Silberman

    Full Text Available The compression of morbidity model posits a breakpoint in the adult lifespan that separates an initial period of relative health from a subsequent period of ever increasing morbidity. Researchers often assume that such a breakpoint exists; however, this assumption is hitherto untested.To test the assumption that a breakpoint exists--which we term a morbidity tipping point--separating a period of relative health from a subsequent deterioration in health status. An analogous tipping point for healthcare costs was also investigated.Four years of adults' (N = 55,550 morbidity and costs data were retrospectively analyzed. Data were collected in Pittsburgh, PA between 2006 and 2009; analyses were performed in Rochester, NY and Ann Arbor, MI in 2012 and 2013. Cohort-sequential and hockey stick regression models were used to characterize long-term trajectories and tipping points, respectively, for both morbidity and costs.Morbidity increased exponentially with age (P<.001. A morbidity tipping point was observed at age 45.5 (95% CI, 41.3-49.7. An exponential trajectory was also observed for costs (P<.001, with a costs tipping point occurring at age 39.5 (95% CI, 32.4-46.6. Following their respective tipping points, both morbidity and costs increased substantially (Ps<.001.Findings support the existence of a morbidity tipping point, confirming an important but untested assumption. This tipping point, however, may occur earlier in the lifespan than is widely assumed. An "avalanche of morbidity" occurred after the morbidity tipping point-an ever increasing rate of morbidity progression. For costs, an analogous tipping point and "avalanche" were observed. The time point at which costs began to increase substantially occurred approximately 6 years before health status began to deteriorate.

  1. The pursuit of balance in sequential randomized trials

    Directory of Open Access Journals (Sweden)

    Raymond P. Guiteras

    2016-06-01

    Full Text Available In many randomized trials, subjects enter the sample sequentially. Because the covariates for all units are not known in advance, standard methods of stratification do not apply. We describe and assess the method of DA-optimal sequential allocation (Atkinson, 1982 for balancing stratification covariates across treatment arms. We provide simulation evidence that the method can provide substantial improvements in precision over commonly employed alternatives. We also describe our experience implementing the method in a field trial of a clean water and handwashing intervention in Dhaka, Bangladesh, the first time the method has been used. We provide advice and software for future researchers.

  2. Points of Transition: Understanding the Constructed Identities of L2 Learners/Users across Time and Space

    Science.gov (United States)

    Adawu, Anthony; Martin-Beltran, Melinda

    2012-01-01

    Using sociocultural and poststructuralist theoretical lenses, this study examines the narrative construction of language-learner identity across time and space. We applied cross-narrative methodologies to analyze language-learning autobiographies and interview data from three English users who had recently transitioned to a U.S. context for…

  3. Point-of-care ultrasonography as a training milestone for internal medicine residents: the time is now.

    Science.gov (United States)

    Sabath, Bruce F; Singh, Gurkeerat

    2016-01-01

    Point-of-care (POC) ultrasonography is considered fundamental in emergency medicine training and recently has become a milestone in critical care fellowship programs as well. Currently, there is no such standard requirement for internal medicine residency programs in the United States. We present a new case and briefly review another case at our institution - a community hospital - in which internal medicine house staff trained in ultrasonography were able to uncover unexpected and critical diagnoses that significantly changed patient care and outcomes. We also review the growing evidence of the application of ultrasound in the diagnosis of a myriad of conditions encountered in general internal medicine as well as the mounting data on the ability of internal medicine residents to apply this technology accurately at the bedside. We advocate that the literature has sufficiently established the role of POC ultrasonography in general internal medicine that there should no longer be any delay in giving this an official place in the development of internal medicine trainees. This may be particularly useful in the community hospital setting where 24-h echocardiography or other sonography may not be readily available.

  4. A Bayesian sequential processor approach to spectroscopic portal system decisions

    Energy Technology Data Exchange (ETDEWEB)

    Sale, K; Candy, J; Breitfeller, E; Guidry, B; Manatt, D; Gosnell, T; Chambers, D

    2007-07-31

    The development of faster more reliable techniques to detect radioactive contraband in a portal type scenario is an extremely important problem especially in this era of constant terrorist threats. Towards this goal the development of a model-based, Bayesian sequential data processor for the detection problem is discussed. In the sequential processor each datum (detector energy deposit and pulse arrival time) is used to update the posterior probability distribution over the space of model parameters. The nature of the sequential processor approach is that a detection is produced as soon as it is statistically justified by the data rather than waiting for a fixed counting interval before any analysis is performed. In this paper the Bayesian model-based approach, physics and signal processing models and decision functions are discussed along with the first results of our research.

  5. Guidelines for time-to-event end point definitions in breast cancer trials: results of the DATECAN initiative (Definition for the Assessment of Time-to-event Endpoints in CANcer trials)†.

    Science.gov (United States)

    Gourgou-Bourgade, S; Cameron, D; Poortmans, P; Asselain, B; Azria, D; Cardoso, F; A'Hern, R; Bliss, J; Bogaerts, J; Bonnefoi, H; Brain, E; Cardoso, M J; Chibaudel, B; Coleman, R; Cufer, T; Dal Lago, L; Dalenc, F; De Azambuja, E; Debled, M; Delaloge, S; Filleron, T; Gligorov, J; Gutowski, M; Jacot, W; Kirkove, C; MacGrogan, G; Michiels, S; Negreiros, I; Offersen, B V; Penault Llorca, F; Pruneri, G; Roche, H; Russell, N S; Schmitt, F; Servent, V; Thürlimann, B; Untch, M; van der Hage, J A; van Tienhoven, G; Wildiers, H; Yarnold, J; Bonnetain, F; Mathoulin-Pélissier, S; Bellera, C; Dabakuyo-Yonli, T S

    2015-05-01

    Using surrogate end points for overall survival, such as disease-free survival, is increasingly common in randomized controlled trials. However, the definitions of several of these time-to-event (TTE) end points are imprecisely which limits interpretation and cross-trial comparisons. The estimation of treatment effects may be directly affected by the definitions of end points. The DATECAN initiative (Definition for the Assessment of Time-to-event Endpoints in CANcer trials) aims to provide recommendations for definitions of TTE end points. We report guidelines for randomized cancer clinical trials (RCTs) in breast cancer. A literature review was carried out to identify TTE end points (primary or secondary) reported in publications of randomized trials or guidelines. An international multidisciplinary panel of experts proposed recommendations for the definitions of these end points based on a validated consensus method that formalize the degree of agreement among experts. Recommended guidelines for the definitions of TTE end points commonly used in RCTs for breast cancer are provided for non-metastatic and metastatic settings. The use of standardized definitions should facilitate comparisons of trial results and improve the quality of trial design and reporting. These guidelines could be of particular interest to those involved in the design, conducting, reporting, or assessment of RCT. © The Author 2015. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  6. Guidelines for time-to-event end point definitions in sarcomas and gastrointestinal stromal tumors (GIST) trials: results of the DATECAN initiative (Definition for the Assessment of Time-to-event Endpoints in CANcer trials)†.

    Science.gov (United States)

    Bellera, C A; Penel, N; Ouali, M; Bonvalot, S; Casali, P G; Nielsen, O S; Delannes, M; Litière, S; Bonnetain, F; Dabakuyo, T S; Benjamin, R S; Blay, J-Y; Bui, B N; Collin, F; Delaney, T F; Duffaud, F; Filleron, T; Fiore, M; Gelderblom, H; George, S; Grimer, R; Grosclaude, P; Gronchi, A; Haas, R; Hohenberger, P; Issels, R; Italiano, A; Jooste, V; Krarup-Hansen, A; Le Péchoux, C; Mussi, C; Oberlin, O; Patel, S; Piperno-Neumann, S; Raut, C; Ray-Coquard, I; Rutkowski, P; Schuetze, S; Sleijfer, S; Stoeckle, E; Van Glabbeke, M; Woll, P; Gourgou-Bourgade, S; Mathoulin-Pélissier, S

    2015-05-01

    The use of potential surrogate end points for overall survival, such as disease-free survival (DFS) or time-to-treatment failure (TTF) is increasingly common in randomized controlled trials (RCTs) in cancer. However, the definition of time-to-event (TTE) end points is rarely precise and lacks uniformity across trials. End point definition can impact trial results by affecting estimation of treatment effect and statistical power. The DATECAN initiative (Definition for the Assessment of Time-to-event End points in CANcer trials) aims to provide recommendations for definitions of TTE end points. We report guidelines for RCT in sarcomas and gastrointestinal stromal tumors (GIST). We first carried out a literature review to identify TTE end points (primary or secondary) reported in publications of RCT. An international multidisciplinary panel of experts proposed recommendations for the definitions of these end points. Recommendations were developed through a validated consensus method formalizing the degree of agreement among experts. Recommended guidelines for the definition of TTE end points commonly used in RCT for sarcomas and GIST are provided for adjuvant and metastatic settings, including DFS, TTF, time to progression and others. Use of standardized definitions should facilitate comparison of trials' results, and improve the quality of trial design and reporting. These guidelines could be of particular interest to research scientists involved in the design, conduct, reporting or assessment of RCT such as investigators, statisticians, reviewers, editors or regulatory authorities. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  7. OPTIMASI OLSR ROUTING PROTOCOL PADA JARINGAN WIRELESS MESH DENGAN ADAPTIVE REFRESHING TIME INTERVAL DAN ENHANCE MULTI POINT RELAY SELECTING ALGORITHM

    Directory of Open Access Journals (Sweden)

    Faosan Mapa

    2014-01-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Wireless Mesh Network (WMN adalah suatu konektivitas jaringan yang self-organized, self-configured dan multi-hop. Tujuan dari WMN adalah menawarkan pengguna suatu bentuk jaringan nirkabel yang dapat dengan mudah berkomunikasi dengan jaringan konvensional dengan kecepatan tinggi dan dengan cakupan yang lebih luas serta biaya awal yang minimal. Diperlukan suatu desain protokol routing yang efisien untuk WMN yang secara adaptif dapat mendukung mesh routers dan mesh clients. Dalam tulisan ini, diusulkan untuk mengoptimalkan protokol OLSR, yang merupakan protokol routing proaktif. Digunakan heuristik yang meningkatkan protokol OLSR melalui adaptive refreshing time interval dan memperbaiki metode MPR selecting algorithm. Suatu analisa dalam meningkatkan protokol OLSR melalui adaptive refreshing time interval dan memperbaiki algoritma pemilihan MPR menunjukkan kinerja yang signifikan dalam hal throughput jika dibandingkan dengan protokol OLSR yang asli. Akan tetapi, terdapat kenaikan dalam hal delay. Pada simulasi yang dilakukan dapat disimpulkan bahwa OLSR dapat dioptimalkan dengan memodifikasi pemilihan node MPR berdasarkan cost effective dan penyesuaian waktu interval refreshing hello message sesuai dengan keadaan

  8. Glycemic Excursions in Type 1 Diabetes in Pregnancy: A Semiparametric Statistical Approach to Identify Sensitive Time Points during Gestation

    Directory of Open Access Journals (Sweden)

    Resmi Gupta

    2017-01-01

    Full Text Available Aim. To examine the gestational glycemic profile and identify specific times during pregnancy that variability in glucose levels, measured by change in velocity and acceleration/deceleration of blood glucose fluctuations, is associated with delivery of a large-for-gestational-age (LGA baby, in women with type 1 diabetes. Methods. Retrospective analysis of capillary blood glucose levels measured multiple times daily throughout gestation in women with type 1 diabetes was performed using semiparametric mixed models. Results. Velocity and acceleration/deceleration in glucose levels varied across gestation regardless of delivery outcome. Compared to women delivering LGA babies, those delivering babies appropriate for gestational age exhibited significantly smaller rates of change and less variation in glucose levels between 180 days of gestation and birth. Conclusions. Use of innovative statistical methods enabled detection of gestational intervals in which blood glucose fluctuation parameters might influence the likelihood of delivering LGA baby in mothers with type 1 diabetes. Understanding dynamics and being able to visualize gestational changes in blood glucose are a potentially useful tool to assist care providers in determining the optimal timing to initiate continuous glucose monitoring.

  9. Magnetic field pitch angle and perpendicular velocity measurements from multi-point time-delay estimation of poloidal correlation reflectometry

    Science.gov (United States)

    Prisiazhniuk, D.; Krämer-Flecken, A.; Conway, G. D.; Happel, T.; Lebschy, A.; Manz, P.; Nikolaeva, V.; Stroth, U.; the ASDEX Upgrade Team

    2017-02-01

    In fusion machines, turbulent eddies are expected to be aligned with the direction of the magnetic field lines and to propagate in the perpendicular direction. Time delay measurements of density fluctuations can be used to calculate the magnetic field pitch angle α and perpendicular velocity {{v}\\bot} profiles. The method is applied to poloidal correlation reflectometry installed at ASDEX Upgrade and TEXTOR, which measure density fluctuations from poloidally and toroidally separated antennas. Validation of the method is achieved by comparing the perpendicular velocity (composed of the E× B drift and the phase velocity of turbulence {{v}\\bot}={{v}E× B}+{{v}\\text{ph}} ) with Doppler reflectometry measurements and with neoclassical {{v}E× B} calculations. An important condition for the application of the method is the presence of turbulence with a sufficiently long decorrelation time. It is shown that at the shear layer the decorrelation time is reduced, limiting the application of the method. The magnetic field pitch angle measured by this method shows the expected dependence on the magnetic field, plasma current and radial position. The profile of the pitch angle reproduces the expected shape and values. However, comparison with the equilibrium reconstruction code cliste suggests an additional inclination of turbulent eddies at the pedestal position (2-3°). This additional angle decreases towards the core and at the edge.

  10. Do you see what I hear? Vantage point preference and visual dominance in a time-space synaesthete.

    Science.gov (United States)

    Jarick, Michelle; Stewart, Mark T; Smilek, Daniel; Dixon, Michael J

    2013-01-01

    Time-space synaesthetes "see" time units organized in a spatial form. While the structure might be invariant for most synaesthetes, the perspective by which some view their calendar is somewhat flexible. One well-studied synaesthete L adopts different viewpoints for months seen vs. heard. Interestingly, L claims to prefer her auditory perspective, even though the month names are represented visually upside down. To verify this, we used a spatial-cueing task that included audiovisual month cues. These cues were either congruent with L's preferred "auditory" viewpoint (auditory-only and auditory + month inverted) or incongruent (upright visual-only and auditory + month upright). Our prediction was that L would show enhanced cueing effects (larger response time difference between valid and invalid targets) following the audiovisual congruent cues since both elicit the "preferred" auditory perspective. Also, when faced with conflicting cues, we predicted L would choose the preferred auditory perspective over the visual perspective. As we expected, L did show enhanced cueing effects following the audiovisual congruent cues that corresponded with her preferred auditory perspective, but that the visual perspective dominated when L was faced with both viewpoints simultaneously. The results are discussed with relation to the reification hypothesis of sequence space synaesthesia (Eagleman, 2009).

  11. Exploring the sequential lineup advantage using WITNESS.

    Science.gov (United States)

    Goodsell, Charles A; Gronlund, Scott D; Carlson, Curt A

    2010-12-01

    Advocates claim that the sequential lineup is an improvement over simultaneous lineup procedures, but no formal (quantitatively specified) explanation exists for why it is better. The computational model WITNESS (Clark, Appl Cogn Psychol 17:629-654, 2003) was used to develop theoretical explanations for the sequential lineup advantage. In its current form, WITNESS produced a sequential advantage only by pairing conservative sequential choosing with liberal simultaneous choosing. However, this combination failed to approximate four extant experiments that exhibited large sequential advantages. Two of these experiments became the focus of our efforts because the data were uncontaminated by likely suspect position effects. Decision-based and memory-based modifications to WITNESS approximated the data and produced a sequential advantage. The next step is to evaluate the proposed explanations and modify public policy recommendations accordingly.

  12. A Field Evaluation of the Time-of-Detection Method to Estimate Population Size and Density for Aural Avian Point Counts

    Directory of Open Access Journals (Sweden)

    Mathew W. Alldredge

    2007-12-01

    Full Text Available The time-of-detection method for aural avian point counts is a new method of estimating abundance, allowing for uncertain probability of detection. The method has been specifically designed to allow for variation in singing rates of birds. It involves dividing the time interval of the point count into several subintervals and recording the detection history of the subintervals when each bird sings. The method can be viewed as generating data equivalent to closed capture-recapture information. The method is different from the distance and multiple-observer methods in that it is not required that all the birds sing during the point count. As this method is new and there is some concern as to how well individual birds can be followed, we carried out a field test of the method using simulated known populations of singing birds, using a laptop computer to send signals to audio stations distributed around a point. The system mimics actual aural avian point counts, but also allows us to know the size and spatial distribution of the populations we are sampling. Fifty 8-min point counts (broken into four 2-min intervals using eight species of birds were simulated. Singing rate of an individual bird of a species was simulated following a Markovian process (singing bouts followed by periods of silence, which we felt was more realistic than a truly random process. The main emphasis of our paper is to compare results from species singing at (high and low homogenous rates per interval with those singing at (high and low heterogeneous rates. Population size was estimated accurately for the species simulated, with a high homogeneous probability of singing. Populations of simulated species with lower but homogeneous singing probabilities were somewhat underestimated. Populations of species simulated with heterogeneous singing probabilities were substantially underestimated. Underestimation was caused by both the very low detection probabilities of all distant

  13. Sequential lineup presentation: Patterns and policy

    OpenAIRE

    Lindsay, R C L; Mansour, Jamal K; Beaudry, J L; Leach, A-M; Bertrand, M I

    2009-01-01

    Sequential lineups were offered as an alternative to the traditional simultaneous lineup. Sequential lineups reduce incorrect lineup selections; however, the accompanying loss of correct identifications has resulted in controversy regarding adoption of the technique. We discuss the procedure and research relevant to (1) the pattern of results found using sequential versus simultaneous lineups; (2) reasons (theory) for differences in witness responses; (3) two methodological issues; and (4) im...

  14. Time dependence of the field energy densities surrounding sources: Application to scalar mesons near point sources and to electromagnetic fields near molecules

    International Nuclear Information System (INIS)

    Persico, F.; Power, E.A.

    1987-01-01

    The time dependence of the dressing-undressing process, i.e., the acquiring or losing by a source of a boson field intensity and hence of a field energy density in its neighborhood, is considered by examining some simple soluble models. First, the loss of the virtual field is followed in time when a point source is suddenly decoupled from a neutral scalar meson field. Second, an initially bare point source acquires a virtual meson cloud as the coupling is switched on. The third example is that of an initially bare molecule interacting with the vacuum of the electromagnetic field to acquire a virtual photon cloud. In all three cases the dressing-undressing is shown to take place within an expanding sphere of radius r = ct centered at the source. At each point in space the energy density tends, for large times, to that of the ground state of the total system. Differences in the time dependence of the dressing between the massive scalar field and the massless electromagnetic field are discussed. The results are also briefly discussed in the light of Feinberg's ideas on the nature of half-dressed states in quantum field theory

  15. The Bacterial Sequential Markov Coalescent.

    Science.gov (United States)

    De Maio, Nicola; Wilson, Daniel J

    2017-05-01

    Bacteria can exchange and acquire new genetic material from other organisms directly and via the environment. This process, known as bacterial recombination, has a strong impact on the evolution of bacteria, for example, leading to the spread of antibiotic resistance across clades and species, and to the avoidance of clonal interference. Recombination hinders phylogenetic and transmission inference because it creates patterns of substitutions (homoplasies) inconsistent with the hypothesis of a single evolutionary tree. Bacterial recombination is typically modeled as statistically akin to gene conversion in eukaryotes, i.e. , using the coalescent with gene conversion (CGC). However, this model can be very computationally demanding as it needs to account for the correlations of evolutionary histories of even distant loci. So, with the increasing popularity of whole genome sequencing, the need has emerged for a faster approach to model and simulate bacterial genome evolution. We present a new model that approximates the coalescent with gene conversion: the bacterial sequential Markov coalescent (BSMC). Our approach is based on a similar idea to the sequential Markov coalescent (SMC)-an approximation of the coalescent with crossover recombination. However, bacterial recombination poses hurdles to a sequential Markov approximation, as it leads to strong correlations and linkage disequilibrium across very distant sites in the genome. Our BSMC overcomes these difficulties, and shows a considerable reduction in computational demand compared to the exact CGC, and very similar patterns in simulated data. We implemented our BSMC model within new simulation software FastSimBac. In addition to the decreased computational demand compared to previous bacterial genome evolution simulators, FastSimBac provides more general options for evolutionary scenarios, allowing population structure with migration, speciation, population size changes, and recombination hotspots. FastSimBac is

  16. The unsteady flow of a nanofluid in the stagnation point region of a time-dependent rotating sphere

    Directory of Open Access Journals (Sweden)

    Malvandi Amir

    2015-01-01

    Full Text Available This paper deals with the unsteady boundary layer flow and heat transfer of nanofluid over a time-dependent rotating sphere where the free stream velocity varies continuously with time. The boundary layer equations were normalized via similarity variables and solved numerically. Best accuracy of the results has been obtained for regular fluid with previous studies. The nanofluid is treated as a two-component mixture (base fluid+nanoparticles that incorporates the effects of Brownian diffusion and thermophoresis simultaneously as the two most important mechanisms of slip velocity in laminar flows. Our outcomes indicated that as A and λ increase, surface shear stresses, heat transfer and concentration rates, climb up. Also, Increasing the thermophoresis Nt is found to decrease in the both values of heat transfer and concentration rates. This decrease supresses for higher thermophoresis number. In addition, it was observed that unlike the heat transfer rate, a rise in Brownian motion Nb, leads to an increase in concentration rate.

  17. Best single time point correlations with AUC for cyclosporine and tacrolimus in HIV-infected kidney and liver transplant recipients.

    Science.gov (United States)

    Frassetto, Lynda A; Tan-Tam, Clara C; Barin, Burc; Browne, Matt; Wolfe, Alan R; Stock, Peter G; Roland, Michelle; Benet, Leslie Z

    2014-03-27

    Interactions between antiretrovirals (ARVs) and transplant immunosuppressant agents (IS) among HIV-infected transplant recipients may lead to lack of efficacy or toxicity. In transplant recipients not infected with HIV, tacrolimus (TAC) trough levels (C0) or cyclosporine (CsA) drawn at C0 or 2 hours after dosing (C2) correlate with drug exposure (area under the curve [AUC]/dose) and outcomes. Because of ARV-IS interactions in HIV-infected individuals, and the high rate of rejection in these subjects, this study investigated the correlations between IS concentrations and exposure to determine the best method to monitor immunosuppressant levels. This study prospectively studied 50 HIV-infected transplant recipients undergoing kidney or liver transplantation evaluating the pharmacokinetics of the IS in 150 studies over time after transplantation (weeks 2 to 4, 12, 28, 52, and 104). IS levels were measured with liquid chromatography-tandem mass spectrometry and AUC calculated using WinNonlin 9.0. Correlation analyses were run on SAS 9.2. CsA concentration at C4 correlated better with AUC than C0 or C2, and over time TAC concentration correlated better at C0 or C2. It is suggested that C0 is acceptable for TAC monitoring, but poor predictability will occur at C0 with CsA. The low correlation of C0 with CsA AUC could be responsible for the higher rejection rates on CsA that has been reported in these subjects.

  18. Biased lineups: sequential presentation reduces the problem.

    Science.gov (United States)

    Lindsay, R C; Lea, J A; Nosworthy, G J; Fulford, J A; Hector, J; LeVan, V; Seabrook, C

    1991-12-01

    Biased lineups have been shown to increase significantly false, but not correct, identification rates (Lindsay, Wallbridge, & Drennan, 1987; Lindsay & Wells, 1980; Malpass & Devine, 1981). Lindsay and Wells (1985) found that sequential lineup presentation reduced false identification rates, presumably by reducing reliance on relative judgment processes. Five staged-crime experiments were conducted to examine the effect of lineup biases and sequential presentation on eyewitness recognition accuracy. Sequential lineup presentation significantly reduced false identification rates from fair lineups as well as from lineups biased with regard to foil similarity, instructions, or witness attire, and from lineups biased in all of these ways. The results support recommendations that police present lineups sequentially.

  19. Clinical evaluation of synthetic aperture sequential beamforming

    DEFF Research Database (Denmark)

    Hansen, Peter Møller; Hemmsen, Martin Christian; Lange, Theis

    2012-01-01

    In this study clinically relevant ultrasound images generated with synthetic aperture sequential beamforming (SASB) is compared to images generated with a conventional technique. The advantage of SASB is the ability to produce high resolution ultrasound images with a high frame rate and at the same...... time massively reduce the amount of generated data. SASB was implemented in a system consisting of a conventional ultrasound scanner connected to a PC via a research interface. This setup enables simultaneous recording with both SASB and conventional technique. Eighteen volunteers were ultrasound...... scanned abdominally, and 84 sequence pairs were recorded. Each sequence pair consists of two simultaneous recordings of the same anatomical location with SASB and conventional B-mode imaging. The images were evaluated in terms of spatial resolution, contrast, unwanted artifacts, and penetration depth...

  20. Gleason-Busch theorem for sequential measurements

    Science.gov (United States)

    Flatt, Kieran; Barnett, Stephen M.; Croke, Sarah

    2017-12-01

    Gleason's theorem is a statement that, given some reasonable assumptions, the Born rule used to calculate probabilities in quantum mechanics is essentially unique [A. M. Gleason, Indiana Univ. Math. J. 6, 885 (1957), 10.1512/iumj.1957.6.56050]. We show that Gleason's theorem contains within it also the structure of sequential measurements, and along with this the state update rule. We give a small set of axioms, which are physically motivated and analogous to those in Busch's proof of Gleason's theorem [P. Busch, Phys. Rev. Lett. 91, 120403 (2003), 10.1103/PhysRevLett.91.120403], from which the familiar Kraus operator form follows. An axiomatic approach has practical relevance as well as fundamental interest, in making clear those assumptions which underlie the security of quantum communication protocols. Interestingly, the two-time formalism is seen to arise naturally in this approach.

  1. Time-sequential changes of differentially expressed miRNAs during the process of anterior lumbar interbody fusion using equine bone protein extract, rhBMP-2 and autograft

    Science.gov (United States)

    Chen, Da-Fu; Zhou, Zhi-Yu; Dai, Xue-Jun; Gao, Man-Man; Huang, Bao-Ding; Liang, Tang-Zhao; Shi, Rui; Zou, Li-Jin; Li, Hai-Sheng; Bünger, Cody; Tian, Wei; Zou, Xue-Nong

    2014-03-01

    The precise mechanism of bone regeneration in different bone graft substitutes has been well studied in recent researches. However, miRNAs regulation of the bone formation has been always mysterious. We developed the anterior lumbar interbody fusion (ALIF) model in pigs using equine bone protein extract (BPE), recombinant human bone morphogenetic protein-2 (rhBMP-2) on an absorbable collagen sponge (ACS), and autograft as bone graft substitute, respectively. The miRNA and gene expression profiles of different bone graft materials were examined using microarray technology and data analysis, including self-organizing maps, KEGG pathway and Biological process GO analyses. We then jointly analyzed miRNA and mRNA profiles of the bone fusion tissue at different time points respectively. Results showed that miRNAs, including let-7, miR-129, miR-21, miR-133, miR-140, miR-146, miR-184, and miR-224, were involved in the regulation of the immune and inflammation response, which provided suitable inflammatory microenvironment for bone formation. At late stage, several miRNAs directly regulate SMAD4, Estrogen receptor 1 and 5-hydroxytryptamine (serotonin) receptor 2C for bone formation. It can be concluded that miRNAs play important roles in balancing the inflammation and bone formation.

  2. Sequential search leads to faster, more efficient fragment-based de novo protein structure prediction.

    Science.gov (United States)

    de Oliveira, Saulo H P; Law, Eleanor C; Shi, Jiye; Deane, Charlotte M

    2018-04-01

    Most current de novo structure prediction methods randomly sample protein conformations and thus require large amounts of computational resource. Here, we consider a sequential sampling strategy, building on ideas from recent experimental work which shows that many proteins fold cotranslationally. We have investigated whether a pseudo-greedy search approach, which begins sequentially from one of the termini, can improve the performance and accuracy of de novo protein structure prediction. We observed that our sequential approach converges when fewer than 20 000 decoys have been produced, fewer than commonly expected. Using our software, SAINT2, we also compared the run time and quality of models produced in a sequential fashion against a standard, non-sequential approach. Sequential prediction produces an individual decoy 1.5-2.5 times faster than non-sequential prediction. When considering the quality of the best model, sequential prediction led to a better model being produced for 31 out of 41 soluble protein validation cases and for 18 out of 24 transmembrane protein cases. Correct models (TM-Score > 0.5) were produced for 29 of these cases by the sequential mode and for only 22 by the non-sequential mode. Our comparison reveals that a sequential search strategy can be used to drastically reduce computational time of de novo protein structure prediction and improve accuracy. Data are available for download from: http://opig.stats.ox.ac.uk/resources. SAINT2 is available for download from: https://github.com/sauloho/SAINT2. saulo.deoliveira@dtc.ox.ac.uk. Supplementary data are available at Bioinformatics online.

  3. Quantifying [{sup 18}F]fluorodeoxyglucose uptake in the arterial wall: the effects of dual time-point imaging and partial volume effect correction

    Energy Technology Data Exchange (ETDEWEB)

    Blomberg, Bjoern A. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark); Bashyam, Arjun; Ramachandran, Abhinay; Gholami, Saeid; Houshmand, Sina; Salavati, Ali; Werner, Tom; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva (Switzerland); University of Groningen, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen (Netherlands)

    2015-08-15

    The human arterial wall is smaller than the spatial resolution of current positron emission tomographs. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake. We evaluated the impact of a novel method for partial volume effect (PVE) correction with contrast-enhanced CT (CECT) assistance on quantification of arterial wall {sup 18}F-FDG uptake at different imaging time-points. Ten subjects were assessed by CECT imaging and dual time-point PET/CT imaging at approximately 60 and 180 min after {sup 18}F-FDG administration. For both time-points, uptake of {sup 18}F-FDG was determined in the aortic wall by calculating the blood pool-corrected maximum standardized uptake value (cSUV{sub MAX}) and cSUV{sub MEAN}. The PVE-corrected SUV{sub MEAN} (pvcSUV{sub MEAN}) was also calculated using {sup 18}F-FDG PET/CT and CECT images. Finally, corresponding target-to-background ratios (TBR) were calculated. At 60 min, pvcSUV{sub MEAN} was on average 3.1 times greater than cSUV{sub MAX} (P <.0001) and 8.5 times greater than cSUV{sub MEAN} (P <.0001). At 180 min, pvcSUV{sub MEAN} was on average 2.6 times greater than cSUV{sub MAX} (P <.0001) and 6.6 times greater than cSUV{sub MEAN} (P <.0001). This study demonstrated that CECT-assisted PVE correction significantly influences quantification of arterial wall {sup 18}F-FDG uptake. Therefore, partial volume effects should be considered when quantifying arterial wall {sup 18}F-FDG uptake with PET. (orig.)

  4. Real-time computing of the environmental consequences of an atmospheric accidental release of radioactive material: user's point of view

    International Nuclear Information System (INIS)

    Boeri, G.; Caracciolo, R.; Dickerson, M.

    1985-07-01

    All calculations of the consequences of an atmospheric release must start with atmospheric dispersion calculations. Time factors make external and inhalation dose estimates of immediate concern closely followed by ground contamination of land, pastures and onch agricultural crops. In general, the difficulties in modeling the source term and atmospheric transport and diffusion account for most of the error in calculating the dose to man. Thus, sophisticated treatment of the dose part of the calculating is not usually justified, though the relative distribution of dose in individual organs may be needed for correct decision marking. This paper emphasizes the atmospheric transport and diffusion part of the dose estimate and relates how this calculation can be used to estimate dose. 12 refs

  5. Applicability of a Single Time Point Strategy for the Prediction of Area Under the Concentration Curve of Linezolid in Patients

    DEFF Research Database (Denmark)

    Srinivas, Nuggehally R; Syed, Muzeeb

    2016-01-01

    Background and Objectives: Linezolid, a oxazolidinone, was the first in class to be approved for the treatment of bacterial infections arising from both susceptible and resistant strains of Gram-positive bacteria. Since overt exposure of linezolid may precipitate serious toxicity issues......, therapeutic drug monitoring (TDM) may be required in certain situations, especially in patients who are prescribed other co-medications. Methods: Using appropriate oral pharmacokinetic data (single dose and steady state) for linezolid, both maximum plasma drug concentration (Cmax) versus area under the plasma...... concentration–time curve (AUC) and minimum plasma drug concentration (Cmin) versus AUC relationship was established by linear regression models. The predictions of the AUC values were performed using published mean/median Cmax or Cmin data and appropriate regression lines. The quotient of observed and predicted...

  6. Immediate Sequential Bilateral Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Erngaard, Ditte

    2015-01-01

    The aim of the present systematic review was to examine the benefits and harms associated with immediate sequential bilateral cataract surgery (ISBCS) with specific emphasis on the rate of complications, postoperative anisometropia, and subjective visual function in order to formulate evidence......-based national Danish guidelines for cataract surgery. A systematic literature review in PubMed, Embase, and Cochrane central databases identified three randomized controlled trials that compared outcome in patients randomized to ISBCS or bilateral cataract surgery on two different dates. Meta-analyses were...... performed using the Cochrane Review Manager software. The quality of the evidence was assessed using the GRADE method (Grading of Recommendation, Assessment, Development, and Evaluation). We did not find any difference in the risk of complications or visual outcome in patients randomized to ISBCS or surgery...

  7. Random and cooperative sequential adsorption

    Science.gov (United States)

    Evans, J. W.

    1993-10-01

    Irreversible random sequential adsorption (RSA) on lattices, and continuum "car parking" analogues, have long received attention as models for reactions on polymer chains, chemisorption on single-crystal surfaces, adsorption in colloidal systems, and solid state transformations. Cooperative generalizations of these models (CSA) are sometimes more appropriate, and can exhibit richer kinetics and spatial structure, e.g., autocatalysis and clustering. The distribution of filled or transformed sites in RSA and CSA is not described by an equilibrium Gibbs measure. This is the case even for the saturation "jammed" state of models where the lattice or space cannot fill completely. However exact analysis is often possible in one dimension, and a variety of powerful analytic methods have been developed for higher dimensional models. Here we review the detailed understanding of asymptotic kinetics, spatial correlations, percolative structure, etc., which is emerging for these far-from-equilibrium processes.

  8. Sequential and simultaneous SLAR block adjustment. [spline function analysis for mapping

    Science.gov (United States)

    Leberl, F.

    1975-01-01

    Two sequential methods of planimetric SLAR (Side Looking Airborne Radar) block adjustment, with and without splines, and three simultaneous methods based on the principles of least squares are evaluated. A limited experiment with simulated SLAR images indicates that sequential block formation with splines followed by external interpolative adjustment is superior to the simultaneous methods such as planimetric block adjustment with similarity transformations. The use of the sequential block formation is recommended, since it represents an inexpensive tool for satisfactory point determination from SLAR images.

  9. Time-lapse analysis of methane quantity in Mary Lee group of coal seams using filter-based multiple-point geostatistical simulation

    Science.gov (United States)

    Karacan, C. Özgen; Olea, Ricardo A.

    2013-01-01

    Coal seam degasification and its success are important for controlling methane, and thus for the health and safety of coal miners. During the course of degasification, properties of coal seams change. Thus, the changes in coal reservoir conditions and in-place gas content as well as methane emission potential into mines should be evaluated by examining time-dependent changes and the presence of major heterogeneities and geological discontinuities in the field. In this work, time-lapsed reservoir and fluid storage properties of the New Castle coal seam, Mary Lee/Blue Creek seam, and Jagger seam of Black Warrior Basin, Alabama, were determined from gas and water production history matching and production forecasting of vertical degasification wellbores. These properties were combined with isotherm and other important data to compute gas-in-place (GIP) and its change with time at borehole locations. Time-lapsed training images (TIs) of GIP and GIP difference corresponding to each coal and date were generated by using these point-wise data and Voronoi decomposition on the TI grid, which included faults as discontinuities for expansion of Voronoi regions. Filter-based multiple-point geostatistical simulations, which were preferred in this study due to anisotropies and discontinuities in the area, were used to predict time-lapsed GIP distributions within the study area. Performed simulations were used for mapping spatial time-lapsed methane quantities as well as their uncertainties within the study area.

  10. Multiple Time-Point 68Ga-PSMA I&T PET/CT for Characterization of Primary Prostate Cancer: Value of Early Dynamic and Delayed Imaging.

    Science.gov (United States)

    Schmuck, Sebastian; Mamach, Martin; Wilke, Florian; von Klot, Christoph A; Henkenberens, Christoph; Thackeray, James T; Sohns, Jan M; Geworski, Lilli; Ross, Tobias L; Wester, Hans-Juergen; Christiansen, Hans; Bengel, Frank M; Derlin, Thorsten

    2017-06-01

    The aims of this study were to gain mechanistic insights into prostate cancer biology using dynamic imaging and to evaluate the usefulness of multiple time-point Ga-prostate-specific membrane antigen (PSMA) I&T PET/CT for the assessment of primary prostate cancer before prostatectomy. Twenty patients with prostate cancer underwent Ga-PSMA I&T PET/CT before prostatectomy. The PET protocol consisted of early dynamic pelvic imaging, followed by static scans at 60 and 180 minutes postinjection (p.i.). SUVs, time-activity curves, quantitative analysis based on a 2-tissue compartment model, Patlak analysis, histopathology, and Gleason grading were compared between prostate cancer and benign prostate gland. Primary tumors were identified on both early dynamic and delayed imaging in 95% of patients. Tracer uptake was significantly higher in prostate cancer compared with benign prostate tissue at any time point (P ≤ 0.0003) and increased over time. Consequently, the tumor-to-nontumor ratio within the prostate gland improved over time (2.8 at 10 minutes vs 17.1 at 180 minutes p.i.). Tracer uptake at both 60 and 180 minutes p.i. was significantly higher in patients with higher Gleason scores (P dynamic and static delayed Ga-PSMA ligand PET images. The tumor-to-nontumor ratio in the prostate gland improves over time, supporting a role of delayed imaging for optimal visualization of prostate cancer.

  11. The problem of the prediction of the time from the point of view of the mechanics and the physics

    International Nuclear Information System (INIS)

    Bjerknes, V.

    2000-01-01

    Of being true, like each man that thinks scientifically that the later atmospheric states are developed of the previous, according to physical laws believes, then it can understand each other that the necessary and enough conditions for a rational solution of the problem of predict in meteorology they are these requirements: it is necessary to know with enough precision the state of the atmosphere in a given instant. It is necessary to know with enough precision the laws that govern the evolution of an atmospheric state toward another. The knowledge of the state of the atmosphere in appropriate instants, fixed by general agreement, is the task of the observational meteorology. For the purposes of a rational forecast of the time, the resolution of this task has not been sufficiently complete. There are two particularly sensitive lagoons. In the first place, the stations that contribute to maintain the service meteorological newspaper are located in earth. In the seas that four recruits of the terrestrial surface cover, and that therefore they exercise a rolling influence, observations are not still made in benefit of the service meteorological newspaper. Also, the observations that are processed for the regular services of meteorology only come from the surface of the soil, and it lacks all fact of the state of the superior layers of air. The technical means that will allow us to fill both lagoons are already in our power. With the help of the radiotelegraphy they will be included, in the environment of the stations, the steam ships with fixed routes, which can send meteorological telegrams daily. And with the big progresses of the aeronautical meteorology in the last years, it will be possible to carry out observations of the superior layers, from stations in surface and, on the sea, from stations steering wheels. It is necessary to wait, because that the time this to arrive in that will be able to prepare, either daily or in certain days, of a complete diagnose of

  12. Textural features and SUV-based variables assessed by dual time point 18F-FDG PET/CT in locally advanced breast cancer.

    Science.gov (United States)

    Garcia-Vicente, Ana María; Molina, David; Pérez-Beteta, Julián; Amo-Salas, Mariano; Martínez-González, Alicia; Bueno, Gloria; Tello-Galán, María Jesús; Soriano-Castrejón, Ángel

    2017-12-01

    To study the influence of dual time point 18F-FDG PET/CT in textural features and SUV-based variables and their relation among them. Fifty-six patients with locally advanced breast cancer (LABC) were prospectively included. All of them underwent a standard 18F-FDG PET/CT (PET-1) and a delayed acquisition (PET-2). After segmentation, SUV variables (SUVmax, SUVmean, and SUVpeak), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were obtained. Eighteen three-dimensional (3D) textural measures were computed including: run-length matrices (RLM) features, co-occurrence matrices (CM) features, and energies. Differences between all PET-derived variables obtained in PET-1 and PET-2 were studied. Significant differences were found between the SUV-based parameters and MTV obtained in the dual time point PET/CT, with higher values of SUV-based variables and lower MTV in the PET-2 with respect to the PET-1. In relation with the textural parameters obtained in dual time point acquisition, significant differences were found for the short run emphasis, low gray-level run emphasis, short run high gray-level emphasis, run percentage, long run emphasis, gray-level non-uniformity, homogeneity, and dissimilarity. Textural variables showed relations with MTV and TLG. Significant differences of textural features were found in dual time point 18F-FDG PET/CT. Thus, a dynamic behavior of metabolic characteristics should be expected, with higher heterogeneity in delayed PET acquisition compared with the standard PET. A greater heterogeneity was found in bigger tumors.

  13. Sequential determination of important ecotoxic radionuclides in nuclear waste samples

    International Nuclear Information System (INIS)

    Bilohuscin, J.

    2016-01-01

    In the dissertation thesis we focused on the development and optimization of a sequential determination method for radionuclides 93 Zr, 94 Nb, 99 Tc and 126 Sn, employing extraction chromatography sorbents TEVA (R) Resin and Anion Exchange Resin, supplied by Eichrom Industries. Prior to the attestation of sequential separation of these proposed radionuclides from radioactive waste samples, a unique sequential procedure of 90 Sr, 239 Pu, 241 Am separation from urine matrices was tried, using molecular recognition sorbents of AnaLig (R) series and extraction chromatography sorbent DGA (R) Resin. On these experiments, four various sorbents were continually used for separation, including PreFilter Resin sorbent, which removes interfering organic materials present in raw urine. After the acquisition of positive results of this sequential procedure followed experiments with a 126 Sn separation using TEVA (R) Resin and Anion Exchange Resin sorbents. Radiochemical recoveries obtained from samples of radioactive evaporate concentrates and sludge showed high efficiency of the separation, while values of 126 Sn were under the minimum detectable activities MDA. Activity of 126 Sn was determined after ingrowth of daughter nuclide 126m Sb on HPGe gamma detector, with minimal contamination of gamma interfering radionuclides with decontamination factors (D f ) higher then 1400 for 60 Co and 47000 for 137 Cs. Based on the acquired experiments and results of these separation procedures, a complex method of sequential separation of 93 Zr, 94 Nb, 99 Tc and 126 Sn was proposed, which included optimization steps similar to those used in previous parts of the dissertation work. Application of the sequential separation method for sorbents TEVA (R) Resin and Anion Exchange Resin on real samples of radioactive wastes provided satisfactory results and an economical, time sparing, efficient method. (author)

  14. Hypovitamininosis D in Childhood Cancer Survivors: Importance of Vitamin D Supplementation and Measurement Over Different Points of Time.

    Science.gov (United States)

    Fouda, Ashraf; Kandil, Shaimaa; Boujettif, Khadijah; Fayea, Najwa

    2018-03-01

    This observational retrospective cross-sectional and case-controlled study measures levels of 25-hydroxy-vitamin D (25-OH-VD) in pediatric cancer survivors at different intervals and assesses the effect of 2 supplementation regimens over a period of 12 months. Sixty-eight patients were included in this quasi-experimental study, of which 32 were boys and 36 were girls. A control group of 30 healthy children were included. It was found that initial 25-OH-VD levels were insufficient (vitamin D during the 12 months in comparison with patients supplemented with 1000 IU/day. Our findings indicate that pediatric cancer survivors who require frequent monitoring of their 25-OH-VD levels yielded better results when supplemented with higher doses of vitamin D over longer periods of time. A course of oral vitamin D supplementation regimen of 50,000 IU/month gave effective results with excellent compliance and no reports of any adverse or harmful effects.

  15. Pb enamel biomarker: Deposition of pre- and postnatal Pb isotope injection in reconstructed time points along rat enamel transect

    International Nuclear Information System (INIS)

    Rinderknecht, A.L.; Kleinman, M.T.; Ericson, J.E.

    2005-01-01

    Exposure to lead (Pb) as well as other heavy metals in the environment is still a matter of public health concern. The development of the enamel biomarker for heavy metal exposure assessment is designed to improve studies of dose-effect relationships to developmental anomalies, particularly embryonic dysfunctions, and to provide a time-specific recount of past exposures. The work presented in this paper demonstrates maternal transfer across the placental barrier of the enriched isotope 206 Pb tracer to the enamel of the rat pup. Likewise, injections of 204 Pb-enriched tracer in the neonate rat resulted in deposition of the tracer in the enamel histology as measured by secondary ion microprobe spectrometry. Through enamel, we were able to observe biological removal and assimilation of prenatal and postnatal tracers, respectively. This research demonstrates that enamel can be used as a biomarker of exposure to Pb and may illustrate the toxicokinetics of incorporating Pb into fetal and neonatal steady-state system processes. The biomarker technique, when completely developed, may be applied to cross-sectional and longitudinal epidemiological research

  16. Multiple memory systems, multiple time points: how science can inform treatment to control the expression of unwanted emotional memories.

    Science.gov (United States)

    Visser, Renée M; Lau-Zhu, Alex; Henson, Richard N; Holmes, Emily A

    2018-03-19

    Memories that have strong emotions associated with them are particularly resilient to forgetting. This is not necessarily problematic, however some aspects of memory can be. In particular, the involuntary expression of those memories, e.g. intrusive memories after trauma, are core to certain psychological disorders. Since the beginning of this century, research using animal models shows that it is possible to change the underlying memory, for example by interfering with its consolidation or reconsolidation. While the idea of targeting maladaptive memories is promising for the treatment of stress and anxiety disorders, a direct application of the procedures used in non-human animals to humans in clinical settings is not straightforward. In translational research, more attention needs to be paid to specifying what aspect of memory (i) can be modified and (ii) should be modified. This requires a clear conceptualization of what aspect of memory is being targeted, and how different memory expressions may map onto clinical symptoms. Furthermore, memory processes are dynamic, so procedural details concerning timing are crucial when implementing a treatment and when assessing its effectiveness. To target emotional memory in its full complexity, including its malleability, science cannot rely on a single method, species or paradigm. Rather, a constructive dialogue is needed between multiple levels of research, all the way 'from mice to mental health'.This article is part of a discussion meeting issue 'Of mice and mental health: facilitating dialogue between basic and clinical neuroscientists'. © 2018 The Authors.

  17. Extended Fitts' model of pointing time in eye-gaze input system - Incorporating effects of target shape and movement direction into modeling.

    Science.gov (United States)

    Murata, Atsuo; Fukunaga, Daichi

    2018-04-01

    This study attempted to investigate the effects of the target shape and the movement direction on the pointing time using an eye-gaze input system and extend Fitts' model so that these factors are incorporated into the model and the predictive power of Fitts' model is enhanced. The target shape, the target size, the movement distance, and the direction of target presentation were set as within-subject experimental variables. The target shape included: a circle, and rectangles with an aspect ratio of 1:1, 1:2, 1:3, and 1:4. The movement direction included eight directions: upper, lower, left, right, upper left, upper right, lower left, and lower right. On the basis of the data for identifying the effects of the target shape and the movement direction on the pointing time, an attempt was made to develop a generalized and extended Fitts' model that took into account the movement direction and the target shape. As a result, the generalized and extended model was found to fit better to the experimental data, and be more effective for predicting the pointing time for a variety of human-computer interaction (HCI) task using an eye-gaze input system. Copyright © 2017. Published by Elsevier Ltd.

  18. Property Analysis of the Real-Time Uncalibrated Phase Delay Product Generated by Regional Reference Stations and Its Influence on Precise Point Positioning Ambiguity Resolution

    Directory of Open Access Journals (Sweden)

    Yong Zhang

    2017-05-01

    Full Text Available The real-time estimation of the wide-lane and narrow-lane Uncalibrated Phase Delay (UPD of satellites is realized by real-time data received from regional reference station networks; The properties of the real-time UPD product and its influence on real-time precise point positioning ambiguity resolution (RTPPP-AR are experimentally analyzed according to real-time data obtained from the regional Continuously Operating Reference Stations (CORS network located in Tianjin, Shanghai, Hong Kong, etc. The results show that the real-time wide-lane and narrow-lane UPD products differ significantly from each other in time-domain characteristics; the wide-lane UPDs have daily stability, with a change rate of less than 0.1 cycle/day, while the narrow-lane UPDs have short-term stability, with significant change in one day. The UPD products generated by different regional networks have obvious spatial characteristics, thus significantly influencing RTPPP-AR: the adoption of real-time UPD products employing the sparse stations in the regional network for estimation is favorable for improving the regional RTPPP-AR up to 99%; the real-time UPD products of different regional networks slightly influence PPP-AR positioning accuracy. After ambiguities are successfully fixed, the real-time dynamic RTPPP-AR positioning accuracy is better than 3 cm in the plane and 8 cm in the upward direction.

  19. Sequential Monte Carlo Instant Radiosity.

    Science.gov (United States)

    Hedman, Peter; Karras, Tero; Lehtinen, Jaakko

    2017-05-01

    Instant Radiosity and its derivatives are interactive methods for efficiently estimating global (indirect) illumination. They represent the last indirect bounce of illumination before the camera as the composite radiance field emitted by a set of virtual point light sources (VPLs). In complex scenes, current algorithms suffer from a difficult combination of two issues: it remains a challenge to distribute VPLs in a manner that simultaneously gives a high-quality indirect illumination solution for each frame, and to do so in a temporally coherent manner. We address both issues by building, and maintaining over time, an adaptive and temporally coherent distribution of VPLs in locations where they bring indirect light to the image. We introduce a novel heuristic sampling method that strives to only move as few of the VPLs between frames as possible. The result is, to the best of our knowledge, the first interactive global illumination algorithm that works in complex, highly-occluded scenes, suffers little from temporal flickering, supports moving cameras and light sources, and is output-sensitive in the sense that it places VPLs in locations that matter most to the final result.

  20. State estimation for temporal point processes

    NARCIS (Netherlands)

    van Lieshout, Maria Nicolette Margaretha

    2015-01-01

    This paper is concerned with combined inference for point processes on the real line observed in a broken interval. For such processes, the classic history-based approach cannot be used. Instead, we adapt tools from sequential spatial point processes. For a range of models, the marginal and

  1. Predictors of exclusive breastfeeding across three time points in Bangladesh: an examination of the 2007, 2011 and 2014 Demographic and Health Survey.

    Science.gov (United States)

    Blackstone, Sarah R; Sanghvi, Tina

    2018-05-01

    The objective of this study was to explore predictors of exclusive breastfeeding (EBF) in Bangladesh using data from 2007, 2011 and 2014, specifically focusing on potential reasons why rates of EBF changed over those time periods. Data on mother/infant pairs with infants <6 months of age were examined at the three time points using the Bangladesh Demographic and Health Survey. The EBF prevalence, changes in EBF since the previous survey and determinants of EBF at each time period were examined using t-tests, χ2 and multilevel logistic regression. The prevalence of EBF was 42.5, 65 and 59.4% in 2007, 2011 and 2014, respectively. The age of the child was significantly associated with EBF across all time points. The largest changes in EBF occurred in the 3- to 5-month age group. Predictors of EBF in this specific age group were similar to overall predictors (e.g. age of the child and region). Participation of the mother in household decisions was a significant predictor in 2014. EBF prevalence in Bangladesh increased between 2007 and 2011 and then decreased between 2011 and 2014. The increase in 2011 may have been the result of widespread initiatives to promote EBF in that time frame. Due to the unexplained decrease in EBF between 2011 and 2014, there is still a need for interventions such as peer counselling, antenatal education and community awareness to promote EBF.

  2. Timing of surgery following neoadjuvant chemoradiotherapy in locally advanced rectal cancer - A comparison of magnetic resonance imaging at two time points and histopathological responses.

    Science.gov (United States)

    West, M A; Dimitrov, B D; Moyses, H E; Kemp, G J; Loughney, L; White, D; Grocott, M P W; Jack, S; Brown, G

    2016-09-01

    There is wide inter-institutional variation in the interval between neoadjuvant chemoradiotherapy (NACRT) and surgery for locally advanced rectal cancer. We aimed to assess the association of magnetic resonance imaging (MRI) at 9 and 14 weeks post-NACRT; T-staging (ymrT) and post-NACRT tumour regression grading (ymrTRG) with histopathological outcomes; histopathological T-stage (ypT) and histopathological tumour regression grading (ypTRG) in order to inform decision-making about timing of surgery. We prospectively studied 35 consecutive patients (26 males) with MRI-defined resection margin threatened rectal cancer who had completed standardized NACRT. Patients underwent a MRI at Weeks 9 and 14 post-NACRT, and surgery at Week 15. Two readers independently assessed MRIs for ymrT, ymrTRG and volume change. ymrT and ymrTRG were analysed against histopathological ypT and ypTRG as predictors by logistic regression modelling and receiver operating characteristic (ROC) curve analyses. Thirty-five patients were recruited. Inter-observer agreement was good for all MR variables (Kappa > 0.61). Considering ypT as an outcome variable, a stronger association of favourable ymrTRG and volume change at Week 14 compared to Week 9 was found (ymrTRG - p = 0.064 vs. p = 0.010; Volume change - p = 0.062 vs. p = 0.007). Similarly, considering ypTRG as an outcome variable, a greater association of favourable ymrTRG and volume change at Week 14 compared to Week 9 was found (ymrTRG - p = 0.005 vs. p = 0.042; Volume change - p = 0.004 vs. 0.055). Following NACRT, greater tumour down-staging and volume reduction was observed at Week 14. Timing of surgery, in relation to NACRT, merits further investigation. NCT01325909. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Trial Sequential Methods for Meta-Analysis

    Science.gov (United States)

    Kulinskaya, Elena; Wood, John

    2014-01-01

    Statistical methods for sequential meta-analysis have applications also for the design of new trials. Existing methods are based on group sequential methods developed for single trials and start with the calculation of a required information size. This works satisfactorily within the framework of fixed effects meta-analysis, but conceptual…

  4. Competence and Praxis: Sequential Analysis in German Sociology

    Directory of Open Access Journals (Sweden)

    Kai-Olaf Maiwald

    2005-09-01

    Full Text Available In German social research nowadays most qualitative methodologies employ sequential analysis. This article explores the similarities and differences in conceptualising and practising this method. First, the working consensus, conceived as a shared set of methodological assumptions, is explicated. Second, with regard to three major paradigms of qualitative research in Germany—conversation analysis, objective hermeneutics, and hermeneutic sociology of knowledge—the dif­ferent ways of doing sequential analysis are investigated to locate the points of departure from a working consensus. It is argued that differences arise from different case-perspectives and, relative to that, from different modes of introducing general knowl­edge, i.e. knowledge that is not specific for the analysed case, into the interpretation. An import­ant notion to emerge from the comparison is the distinction between competence and praxis. URN: urn:nbn:de:0114-fqs0503310

  5. Research on parallel algorithm for sequential pattern mining

    Science.gov (United States)

    Zhou, Lijuan; Qin, Bai; Wang, Yu; Hao, Zhongxiao

    2008-03-01

    Sequential pattern mining is the mining of frequent sequences related to time or other orders from the sequence database. Its initial motivation is to discover the laws of customer purchasing in a time section by finding the frequent sequences. In recent years, sequential pattern mining has become an important direction of data mining, and its application field has not been confined to the business database and has extended to new data sources such as Web and advanced science fields such as DNA analysis. The data of sequential pattern mining has characteristics as follows: mass data amount and distributed storage. Most existing sequential pattern mining algorithms haven't considered the above-mentioned characteristics synthetically. According to the traits mentioned above and combining the parallel theory, this paper puts forward a new distributed parallel algorithm SPP(Sequential Pattern Parallel). The algorithm abides by the principal of pattern reduction and utilizes the divide-and-conquer strategy for parallelization. The first parallel task is to construct frequent item sets applying frequent concept and search space partition theory and the second task is to structure frequent sequences using the depth-first search method at each processor. The algorithm only needs to access the database twice and doesn't generate the candidated sequences, which abates the access time and improves the mining efficiency. Based on the random data generation procedure and different information structure designed, this paper simulated the SPP algorithm in a concrete parallel environment and implemented the AprioriAll algorithm. The experiments demonstrate that compared with AprioriAll, the SPP algorithm had excellent speedup factor and efficiency.

  6. Sequential lineup laps and eyewitness accuracy.

    Science.gov (United States)

    Steblay, Nancy K; Dietrich, Hannah L; Ryan, Shannon L; Raczynski, Jeanette L; James, Kali A

    2011-08-01

    Police practice of double-blind sequential lineups prompts a question about the efficacy of repeated viewings (laps) of the sequential lineup. Two laboratory experiments confirmed the presence of a sequential lap effect: an increase in witness lineup picks from first to second lap, when the culprit was a stranger. The second lap produced more errors than correct identifications. In Experiment 2, lineup diagnosticity was significantly higher for sequential lineup procedures that employed a single versus double laps. Witnesses who elected to view a second lap made significantly more errors than witnesses who chose to stop after one lap or those who were required to view two laps. Witnesses with prior exposure to the culprit did not exhibit a sequential lap effect.

  7. Sequential Product of Quantum Effects: An Overview

    Science.gov (United States)

    Gudder, Stan

    2010-12-01

    This article presents an overview for the theory of sequential products of quantum effects. We first summarize some of the highlights of this relatively recent field of investigation and then provide some new results. We begin by discussing sequential effect algebras which are effect algebras endowed with a sequential product satisfying certain basic conditions. We then consider sequential products of (discrete) quantum measurements. We next treat transition effect matrices (TEMs) and their associated sequential product. A TEM is a matrix whose entries are effects and whose rows form quantum measurements. We show that TEMs can be employed for the study of quantum Markov chains. Finally, we prove some new results concerning TEMs and vector densities.

  8. Sequential experimental design based generalised ANOVA

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Souvik, E-mail: csouvik41@gmail.com; Chowdhury, Rajib, E-mail: rajibfce@iitr.ac.in

    2016-07-15

    Over the last decade, surrogate modelling technique has gained wide popularity in the field of uncertainty quantification, optimization, model exploration and sensitivity analysis. This approach relies on experimental design to generate training points and regression/interpolation for generating the surrogate. In this work, it is argued that conventional experimental design may render a surrogate model inefficient. In order to address this issue, this paper presents a novel distribution adaptive sequential experimental design (DA-SED). The proposed DA-SED has been coupled with a variant of generalised analysis of variance (G-ANOVA), developed by representing the component function using the generalised polynomial chaos expansion. Moreover, generalised analytical expressions for calculating the first two statistical moments of the response, which are utilized in predicting the probability of failure, have also been developed. The proposed approach has been utilized in predicting probability of failure of three structural mechanics problems. It is observed that the proposed approach yields accurate and computationally efficient estimate of the failure probability.

  9. Sodium borocaptate (BSH) for Boron Neutron Capture Therapy (BNCT) in the hamster cheek pouch oral cancer model: boron biodistribution at 9 post administration time-points

    International Nuclear Information System (INIS)

    Garabalino, M.A.; Heber, E.M.; Monti, Hughes A.; Molinari, A.J.; Pozzi, E.C.C.; Trivillin, V.A.; Schwint, Amanda E.

    2011-01-01

    The therapeutic success of Boron Neutron Capture Therapy (BNCT) depends centrally on boron concentration in tumor and healthy tissue. We previously demonstrated the therapeutic efficacy of boronophenylalanine (BPA) and sodium decahydrodecaborate (GB-10) as boron carriers for BNCT in the hamster cheek pouch oral cancer model. Given the clinical relevance of sodium mercaptoundecahydro-closo-dodecaborate (BSH) as a boron carrier, the aim of the present study was to expand the ongoing BSH biodistribution studies in the hamster cheek pouch oral cancer model. In particular, we studied 3 additional post-administration time-points and increased the sample size corresponding to the time-points evaluated previously, to select more accurately the post-administration time at which neutron irradiation would potentially confer the greatest therapeutic advantage. BSH was dissolved in saline solution in anaerobic conditions to avoid the formation of the dimer BSSB and its oxides which are toxic. The solution was injected intravenously at a dose of 50 mg 10 B/kg (88 mg BSH / kg). Different groups of animals were killed humanely at 7, 8, and 10 h after administration of BSH. The sample size corresponding to the time-points 3, 4, 6, 9 and 12 h was increased. Samples of blood, tumor, precancerous tissue, normal pouch tissue, cheek mucosa, parotid gland, palate, skin, tongue, spinal cord marrow, brain, liver, kidney, spleen and lung were processed for boron measurement by Optic Emission Spectroscopy (ICP-OES). Boron concentration in tumor peaked to 24-34 ppm, 3-10 h post-administration of BSH, with a spread in values that resembled that previously reported in other experimental models and human subjects. The boron concentration ratios tumor/normal pouch tissue and tumor/blood ranged from 1.3 to 1.8. No selective tumor uptake was observed at any of the time points evaluated. The times post-administration of BSH that would be therapeutically most useful would be 5, 7 and 9 h. The

  10. The effect of the vertical part of the path on the real time Feynman rules in finite temperature field theory 2-point functions and vacuum diagrams

    International Nuclear Information System (INIS)

    Gelis, F.

    1996-01-01

    The effect of the contribution of the vertical part of the real time path is studied completely in the case of two points functions and vacuum diagrams. Indeed, this vertical part generally contributes in the calculation of a given graph. Moreover, this contribution is essential in order to have a consistent equilibrium theory: thanks to this contribution, the Green functions are effectively invariant by time translation, as they should be. As a by product, it is shown that the perturbative calculations give a result which does not depend on the initial time t I and final time t F of the path. The property of independence with respect to t I is closely related to the KMS conditions, i.e. to the fact the system is in thermal equilibrium. In the case of two point functions and vacuum diagrams, the contribution of the vertical part can be taken into account by the n(vertical stroke k 0 vertical stroke) prescription in the usual RTF Feynman rules. The extra Feynman rule needed for vacuum diagrams is shown not to be related directly to the contribution of the vertical part of the path. (orig.). With 4 figs

  11. Diagnostic value of ST-segment deviations during cardiac exercise stress testing: Systematic comparison of different ECG leads and time-points.

    Science.gov (United States)

    Puelacher, Christian; Wagener, Max; Abächerli, Roger; Honegger, Ursina; Lhasam, Nundsin; Schaerli, Nicolas; Prêtre, Gil; Strebel, Ivo; Twerenbold, Raphael; Boeddinghaus, Jasper; Nestelberger, Thomas; Rubini Giménez, Maria; Hillinger, Petra; Wildi, Karin; Sabti, Zaid; Badertscher, Patrick; Cupa, Janosch; Kozhuharov, Nikola; du Fay de Lavallaz, Jeanne; Freese, Michael; Roux, Isabelle; Lohrmann, Jens; Leber, Remo; Osswald, Stefan; Wild, Damian; Zellweger, Michael J; Mueller, Christian; Reichlin, Tobias

    2017-07-01

    Exercise ECG stress testing is the most widely available method for evaluation of patients with suspected myocardial ischemia. Its major limitation is the relatively poor accuracy of ST-segment changes regarding ischemia detection. Little is known about the optimal method to assess ST-deviations. A total of 1558 consecutive patients undergoing bicycle exercise stress myocardial perfusion imaging (MPI) were enrolled. Presence of inducible myocardial ischemia was adjudicated using MPI results. The diagnostic value of ST-deviations for detection of exercise-induced myocardial ischemia was systematically analyzed 1) for each individual lead, 2) at three different intervals after the J-point (J+40ms, J+60ms, J+80ms), and 3) at different time points during the test (baseline, maximal workload, 2min into recovery). Exercise-induced ischemia was detected in 481 (31%) patients. The diagnostic accuracy of ST-deviations was highest at +80ms after the J-point, and at 2min into recovery. At this point, ST-amplitude showed an AUC of 0.63 (95% CI 0.59-0.66) for the best-performing lead I. The combination of ST-amplitude and ST-slope in lead I did not increase the AUC. Lead I reached a sensitivity of 37% and a specificity of 83%, with similar sensitivity to manual ECG analysis (34%, p=0.31) but lower specificity (90%, pST-deviations is highest when evaluated at +80ms after the J-point, and at 2min into recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Guidelines for the definition of time-to-event end points in renal cell cancer clinical trials: results of the DATECAN project†.

    Science.gov (United States)

    Kramar, A; Negrier, S; Sylvester, R; Joniau, S; Mulders, P; Powles, T; Bex, A; Bonnetain, F; Bossi, A; Bracarda, S; Bukowski, R; Catto, J; Choueiri, T K; Crabb, S; Eisen, T; El Demery, M; Fitzpatrick, J; Flamand, V; Goebell, P J; Gravis, G; Houédé, N; Jacqmin, D; Kaplan, R; Malavaud, B; Massard, C; Melichar, B; Mourey, L; Nathan, P; Pasquier, D; Porta, C; Pouessel, D; Quinn, D; Ravaud, A; Rolland, F; Schmidinger, M; Tombal, B; Tosi, D; Vauleon, E; Volpe, A; Wolter, P; Escudier, B; Filleron, T

    2015-12-01

    In clinical trials, the use of intermediate time-to-event end points (TEEs) is increasingly common, yet their choice and definitions are not standardized. This limits the usefulness for comparing treatment effects between studies. The aim of the DATECAN Kidney project is to clarify and recommend definitions of TEE in renal cell cancer (RCC) through a formal consensus method for end point definitions. A formal modified Delphi method was used for establishing consensus. From a 2006-2009 literature review, the Steering Committee (SC) selected 9 TEE and 15 events in the nonmetastatic (NM) and metastatic/advanced (MA) RCC disease settings. Events were scored on the range of 1 (totally disagree to include) to 9 (totally agree to include) in the definition of each end point. Rating Committee (RC) experts were contacted for the scoring rounds. From these results, final recommendations were established for selecting pertinent end points and the associated events. Thirty-four experts scored 121 events for 9 end points. Consensus was reached for 31%, 43% and 85% events during the first, second and third rounds, respectively. The expert recommend the use of three and two endpoints in NM and MA setting, respectively. In the NM setting: disease-free survival (contralateral RCC, appearance of metastases, local or regional recurrence, death from RCC or protocol treatment), metastasis-free survival (appearance of metastases, regional recurrence, death from RCC); and local-regional-free survival (local or regional recurrence, death from RCC). In the MA setting: kidney cancer-specific survival (death from RCC or protocol treatment) and progression-free survival (death from RCC, local, regional, or metastatic progression). The consensus method revealed that intermediate end points have not been well defined, because all of the selected end points had at least one event definition for which no consensus was obtained. These clarified definitions of TEE should become standard practice in

  13. Terrestrial laser scanning point clouds time series for the monitoring of slope movements: displacement measurement using image correlation and 3D feature tracking

    Science.gov (United States)

    Bornemann, Pierrick; Jean-Philippe, Malet; André, Stumpf; Anne, Puissant; Julien, Travelletti

    2016-04-01

    Dense multi-temporal point clouds acquired with terrestrial laser scanning (TLS) have proved useful for the study of structure and kinematics of slope movements. Most of the existing deformation analysis methods rely on the use of interpolated data. Approaches that use multiscale image correlation provide a precise and robust estimation of the observed movements; however, for non-rigid motion patterns, these methods tend to underestimate all the components of the movement. Further, for rugged surface topography, interpolated data introduce a bias and a loss of information in some local places where the point cloud information is not sufficiently dense. Those limits can be overcome by using deformation analysis exploiting directly the original 3D point clouds assuming some hypotheses on the deformation (e.g. the classic ICP algorithm requires an initial guess by the user of the expected displacement patterns). The objective of this work is therefore to propose a deformation analysis method applied to a series of 20 3D point clouds covering the period October 2007 - October 2015 at the Super-Sauze landslide (South East French Alps). The dense point clouds have been acquired with a terrestrial long-range Optech ILRIS-3D laser scanning device from the same base station. The time series are analyzed using two approaches: 1) a method of correlation of gradient images, and 2) a method of feature tracking in the raw 3D point clouds. The estimated surface displacements are then compared with GNSS surveys on reference targets. Preliminary results tend to show that the image correlation method provides a good estimation of the displacement fields at first order, but shows limitations such as the inability to track some deformation patterns, and the use of a perspective projection that does not maintain original angles and distances in the correlated images. Results obtained with 3D point clouds comparison algorithms (C2C, ICP, M3C2) bring additional information on the

  14. Multilevel sequential Monte Carlo samplers

    KAUST Repository

    Beskos, Alexandros; Jasra, Ajay; Law, Kody; Tempone, Raul; Zhou, Yan

    2016-01-01

    In this article we consider the approximation of expectations w.r.t. probability distributions associated to the solution of partial differential equations (PDEs); this scenario appears routinely in Bayesian inverse problems. In practice, one often has to solve the associated PDE numerically, using, for instance finite element methods which depend on the step-size level . hL. In addition, the expectation cannot be computed analytically and one often resorts to Monte Carlo methods. In the context of this problem, it is known that the introduction of the multilevel Monte Carlo (MLMC) method can reduce the amount of computational effort to estimate expectations, for a given level of error. This is achieved via a telescoping identity associated to a Monte Carlo approximation of a sequence of probability distributions with discretization levels . ∞>h0>h1⋯>hL. In many practical problems of interest, one cannot achieve an i.i.d. sampling of the associated sequence and a sequential Monte Carlo (SMC) version of the MLMC method is introduced to deal with this problem. It is shown that under appropriate assumptions, the attractive property of a reduction of the amount of computational effort to estimate expectations, for a given level of error, can be maintained within the SMC context. That is, relative to exact sampling and Monte Carlo for the distribution at the finest level . hL. The approach is numerically illustrated on a Bayesian inverse problem. © 2016 Elsevier B.V.

  15. Multilevel sequential Monte Carlo samplers

    KAUST Repository

    Beskos, Alexandros

    2016-08-29

    In this article we consider the approximation of expectations w.r.t. probability distributions associated to the solution of partial differential equations (PDEs); this scenario appears routinely in Bayesian inverse problems. In practice, one often has to solve the associated PDE numerically, using, for instance finite element methods which depend on the step-size level . hL. In addition, the expectation cannot be computed analytically and one often resorts to Monte Carlo methods. In the context of this problem, it is known that the introduction of the multilevel Monte Carlo (MLMC) method can reduce the amount of computational effort to estimate expectations, for a given level of error. This is achieved via a telescoping identity associated to a Monte Carlo approximation of a sequence of probability distributions with discretization levels . ∞>h0>h1⋯>hL. In many practical problems of interest, one cannot achieve an i.i.d. sampling of the associated sequence and a sequential Monte Carlo (SMC) version of the MLMC method is introduced to deal with this problem. It is shown that under appropriate assumptions, the attractive property of a reduction of the amount of computational effort to estimate expectations, for a given level of error, can be maintained within the SMC context. That is, relative to exact sampling and Monte Carlo for the distribution at the finest level . hL. The approach is numerically illustrated on a Bayesian inverse problem. © 2016 Elsevier B.V.

  16. Sequential provisional implant prosthodontics therapy.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Schnader, Yale E; Shapiro, Herbert J

    2012-01-01

    The fabrication and long-term use of first- and second-stage provisional implant prostheses is critical to create a favorable prognosis for function and esthetics of a fixed-implant supported prosthesis. The fixed metal and acrylic resin cemented first-stage prosthesis, as reviewed in Part I, is needed for prevention of adjacent and opposing tooth movement, pressure on the implant site as well as protection to avoid micromovement of the freshly placed implant body. The second-stage prosthesis, reviewed in Part II, should be used following implant uncovering and abutment installation. The patient wears this provisional prosthesis until maturation of the bone and healing of soft tissues. The second-stage provisional prosthesis is also a fail-safe mechanism for possible early implant failures and also can be used with late failures and/or for the necessity to repair the definitive prosthesis. In addition, the screw-retained provisional prosthesis is used if and when an implant requires removal or other implants are to be placed as in a sequential approach. The creation and use of both first- and second-stage provisional prostheses involve a restorative dentist, dental technician, surgeon, and patient to work as a team. If the dentist alone cannot do diagnosis and treatment planning, surgery, and laboratory techniques, he or she needs help by employing the expertise of a surgeon and a laboratory technician. This team approach is essential for optimum results.

  17. A path-level exact parallelization strategy for sequential simulation

    Science.gov (United States)

    Peredo, Oscar F.; Baeza, Daniel; Ortiz, Julián M.; Herrero, José R.

    2018-01-01

    Sequential Simulation is a well known method in geostatistical modelling. Following the Bayesian approach for simulation of conditionally dependent random events, Sequential Indicator Simulation (SIS) method draws simulated values for K categories (categorical case) or classes defined by K different thresholds (continuous case). Similarly, Sequential Gaussian Simulation (SGS) method draws simulated values from a multivariate Gaussian field. In this work, a path-level approach to parallelize SIS and SGS methods is presented. A first stage of re-arrangement of the simulation path is performed, followed by a second stage of parallel simulation for non-conflicting nodes. A key advantage of the proposed parallelization method is to generate identical realizations as with the original non-parallelized methods. Case studies are presented using two sequential simulation codes from GSLIB: SISIM and SGSIM. Execution time and speedup results are shown for large-scale domains, with many categories and maximum kriging neighbours in each case, achieving high speedup results in the best scenarios using 16 threads of execution in a single machine.

  18. Standardized method for reproducing the sequential X-rays flap

    International Nuclear Information System (INIS)

    Brenes, Alejandra; Molina, Katherine; Gudino, Sylvia

    2009-01-01

    A method is validated to estandardize in the taking, developing and analysis of bite-wing radiographs taken in sequential way, in order to compare and evaluate detectable changes in the evolution of the interproximal lesions through time. A radiographic positioner called XCP® is modified by means of a rigid acrylic guide, to achieve proper of the X ray equipment core positioning relative to the XCP® ring and the reorientation during the sequential x-rays process. 16 subjects of 4 to 40 years old are studied for a total number of 32 registries. Two x-rays of the same block of teeth of each subject have been taken in sequential way, with a minimal difference of 30 minutes between each one, before the placement of radiographic attachment. The images have been digitized with a Super Cam® scanner and imported to a software. The measurements in X and Y-axis for both x-rays were performed to proceed to compare. The intraclass correlation index (ICI) has shown that the proposed method is statistically related to measurement (mm) obtained in the X and Y-axis for both sequential series of x-rays (p=0.01). The measures of central tendency and dispersion have shown that the usual occurrence is indifferent between the two measurements (Mode 0.000 and S = 0083 and 0.109) and that the probability of occurrence of different values is lower than expected. (author) [es

  19. POLYP: an automatic device for drawing sequential samples of gas

    Energy Technology Data Exchange (ETDEWEB)

    Gaglione, P; Koechler, C; Stanchi, L

    1974-12-01

    Polyp is an automatic device consisting of electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. The other seven pumps will inflate sequentially the other bags. The instrument is powered by rechargeable batteries and realized with C-MUS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof.

  20. POLYP: an automatic device for drawing sequential samples of gas

    International Nuclear Information System (INIS)

    Gaglione, P.; Koechler, C.; Stanchi, L.

    1974-12-01

    POLYP is an automatic device consisting of an electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. Thereafter the other seven pumps will inflate sequentially the other bag. The instrument is powered by rechargeable batteries and realized with C-MOS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof

  1. Sequential Apparent Diffusion Coefficient for Assessment of Tumor Progression in Patients with Low-Grade Glioma.

    Science.gov (United States)

    Chen, I E; Swinburne, N; Tsankova, N M; Hefti, M M; Aggarwal, A; Doshi, A H; Hormigo, A; Delman, B N; Nael, K

    2018-04-19

    Early and accurate identification of tumor progression in patients with low-grade gliomas is challenging. We aimed to assess the role of quantitative ADC analysis in the sequential follow-up of patients with low-grade gliomas as a potential imaging marker of tumor stability or progression. In this retrospective study, patients with a diagnosis of low-grade glioma with at least 12 months of imaging follow-up were retrospectively reviewed. Two neuroradiologists independently reviewed sequential MR imaging in each patient to determine tumor progression using the Response Assessment in Neuro-Oncology criteria. Normalized mean ADC (ADC mean ) and 10th percentile ADC (ADC 10 ) values from FLAIR hyperintense tumor volume were calculated for each MR image and compared between patients with stable disease versus tumor progression using univariate analysis. The interval change of ADC values between sequential scans was used to differentiate stable disease from progression using the Fisher exact test. Twenty-eight of 69 patients who were evaluated met our inclusion criteria. Fifteen patients were classified as stable versus 13 patients as having progression based on consensus reads of MRIs and the Response Assessment in Neuro-Oncology criteria. The interval change of ADC values showed greater concordance with ultimate lesion disposition than quantitative ADC values at a single time point. The interval change in ADC 10 matched the expected pattern in 12/13 patients with tumor progression (overall diagnostic accuracy of 86%, P average, the ADC 10 interval change predicted progression 8 months before conventional MR imaging. The interval change of ADC 10 values can be used to identify progression versus stability of low-grade gliomas with a diagnostic accuracy of 86% and before apparent radiologic progression on conventional MR imaging. © 2018 by American Journal of Neuroradiology.

  2. Limited Sampling Strategy for the Prediction of Area Under the Curve (AUC) of Statins: Reliability of a Single Time Point for AUC Prediction for Pravastatin and Simvastatin.

    Science.gov (United States)

    Srinivas, N R

    2016-02-01

    Statins are widely prescribed medicines and are also available in fixed dose combinations with other drugs to treat several chronic ailments. Given the safety issues associated with statins it may be important to assess feasibility of a single time concentration strategy for prediction of exposure (area under the curve; AUC). The peak concentration (Cmax) was used to establish relationship with AUC separately for pravastatin and simvastatin using published pharmacokinetic data. The regression equations generated for statins were used to predict the AUC values from various literature references. The fold difference of the observed divided by predicted values along with correlation coefficient (r) were used to judge the feasibility of the single time point approach. Both pravastatin and simvastatin showed excellent correlation of Cmax vs. AUC values with r value ≥ 0.9638 (pAUC predictions and >81% of the predicted values were in a narrower range of >0.75-fold but AUC values showed excellent correlation for pravastatin (r=0.9708, n=115; pAUC predictions. On the basis of the present work, it is feasible to develop a single concentration time point strategy that coincides with Cmax occurrence for both pravastatin and simvastatin from a therapeutic drug monitoring perspective. © Georg Thieme Verlag KG Stuttgart · New York.

  3. The Clinical Role of Dual-Time-Point {sup 18}F-FDG PET/CT in Differential Diagnosis of the Thyroid Incidentaloma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sinae; Park, Taegyu; Park, Soyeon; Pahk, Kisoo; Rhee, Seunghong; Cho, Jaehyuk; Jeong, Eugene; Kim, Sungeun; Choe, Jae Gol [Korea Univ., Seoul (Korea, Republic of)

    2014-06-15

    Thyroid incidentalomas are common findings during imaging studies including {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT) for cancer evaluation. Although the overall incidence of incidental thyroid uptake detected on PET imaging is low, clinical attention should be warranted owing to the high incidence of harboring primary thyroid malignancy.We retrospectively reviewed 2,368 dual-time-point {sup 18}F-FDG PET/CT cases that were undertaken for cancer evaluation from November 2007 to February 2009, to determine the clinical impact of dual-time-point imaging in the differential diagnosis of thyroid incidentalomas. Focal thyroid uptake was identified in 64 PET cases and final diagnosis was clarified with cytology/histology in a total of 27 patients with {sup 18}F-FDG-avid incidental thyroid lesion. The maximum standardized uptake value (SUVmax) of the initial image (SUV1) and SUVmax of the delayed image (SUV2) were determined, and the retention index (RI) was calculated by dividing the difference between SUV2 and SUV1 by SUV1 (i. e., RI=[SUV2-SUV1]/SUV1Χ100). These indices were compared between patient groups that were proven to have pathologically benign or malignant thyroid lesions. There was no statistically significant difference in SUV1 between benign and malignant lesions. SUV2 and RI of the malignant lesions were significantly higher than the benign lesions. The areas under the ROC curves showed that SUV2 and RI have the ability to discriminate between benign and malignant thyroid lesions. The predictability of dual-time-point PET parameters for thyroid malignancy was assessed by ROC curve analyses. When SUV2 of 3.9 was used as cut-off threshold, malignancy on the pathology could be predicted with a sensitivity of 87.5 % and specificity of 75 %. A thyroid lesion that shows RI greater than 12.5 % could be expected to be malignant (sensitivity 88.9 %, specificity 66.3 %). All malignant lesions showed an

  4. Study of thermal behavior of vitamin D3 by pyrolysis-GC-MS in combination with boiling point-retention time correlation.

    Science.gov (United States)

    Sun, Yu'an; Liu, Baoxia; Wang, Guoqing; Zhang, Rongjie; Xie, Bing

    2005-01-01

    The thermal behavior of vitamin D3 was studied based on pyrolysis-GC-MS technique. It was pyrolyzed at 600 degrees C, 750 degrees C, 900 degrees C, respectively. The pyrolysis product were separated With an HP-5 column and identified by the NIST mass spectral search program in combination with the correlation of boiling point and retention time (BP-RT). There are totally 50 components, including mono aromatics and polycyclic aromatic hydrocarbons (PAHs), were determined. It is shown that the contents of the PAHs are increasing with the increasing of the pyrolysis temperature. The contents of the determined components vary from 0.04% to 37.08%.

  5. Digital Investigations of AN Archaeological Smart Point Cloud: a Real Time Web-Based Platform to Manage the Visualisation of Semantical Queries

    Science.gov (United States)

    Poux, F.; Neuville, R.; Hallot, P.; Van Wersch, L.; Luczfalvy Jancsó, A.; Billen, R.

    2017-05-01

    While virtual copies of the real world tend to be created faster than ever through point clouds and derivatives, their working proficiency by all professionals' demands adapted tools to facilitate knowledge dissemination. Digital investigations are changing the way cultural heritage researchers, archaeologists, and curators work and collaborate to progressively aggregate expertise through one common platform. In this paper, we present a web application in a WebGL framework accessible on any HTML5-compatible browser. It allows real time point cloud exploration of the mosaics in the Oratory of Germigny-des-Prés, and emphasises the ease of use as well as performances. Our reasoning engine is constructed over a semantically rich point cloud data structure, where metadata has been injected a priori. We developed a tool that directly allows semantic extraction and visualisation of pertinent information for the end users. It leads to efficient communication between actors by proposing optimal 3D viewpoints as a basis on which interactions can grow.

  6. A physical model study of the travel times and reflection points of SH-waves reflected from transversely isotropic media with tilted symmetry axes

    Science.gov (United States)

    Sun, Li-Chung; Chang, Young-Fo; Chang, Chih-Hsiung; Chung, Chia-Lung

    2012-05-01

    In reflection seismology, detailed knowledge of how seismic waves propagate in anisotropic media is important for locating reservoirs accurately. The SH-wave possesses a pure mode polarization which does not convert to P- and SV-waves when reflecting from a horizontal interface, and vice versa. The simplicity of the SH-wave thus provides an easy way to view the details of SH-wave propagation in anisotropic media. In this study, we attempt to inspect the theoretical reflection moveouts of SH-waves reflected from transversely isotropic (TI) layers with tilted symmetry axes and to verify the reflection point, which could be shifted away from the common midpoint (CMP), by numerical calculations and physical modelling. In travel time-offset analyses, the moveout curves of SH-waves reflected from horizontal TI media (TIM) with different tilted angles of symmetry axes are computed by the TI modified hyperbolic equation and Fermat's principle, respectively. It turns out that both the computed moveout curves are similar and fit well to the observed physical data. The reflection points of SH-waves for a CMP gather computed by Fermat's principle show that they are close to the CMP for TIM with the vertical and horizontal symmetry axes, but they shift away from the CMP for the other tilted angles of symmetry axes. The shifts of the reflection points of the SH-waves from the CMP were verified by physical modelling.

  7. Tipping Point

    Medline Plus

    Full Text Available ... en español Blog About OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by ... danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe ...

  8. Tradable permit allocations and sequential choice

    Energy Technology Data Exchange (ETDEWEB)

    MacKenzie, Ian A. [Centre for Economic Research, ETH Zuerich, Zurichbergstrasse 18, 8092 Zuerich (Switzerland)

    2011-01-15

    This paper investigates initial allocation choices in an international tradable pollution permit market. For two sovereign governments, we compare allocation choices that are either simultaneously or sequentially announced. We show sequential allocation announcements result in higher (lower) aggregate emissions when announcements are strategic substitutes (complements). Whether allocation announcements are strategic substitutes or complements depends on the relationship between the follower's damage function and governments' abatement costs. When the marginal damage function is relatively steep (flat), allocation announcements are strategic substitutes (complements). For quadratic abatement costs and damages, sequential announcements provide a higher level of aggregate emissions. (author)

  9. Sequential Generalized Transforms on Function Space

    Directory of Open Access Journals (Sweden)

    Jae Gil Choi

    2013-01-01

    Full Text Available We define two sequential transforms on a function space Ca,b[0,T] induced by generalized Brownian motion process. We then establish the existence of the sequential transforms for functionals in a Banach algebra of functionals on Ca,b[0,T]. We also establish that any one of these transforms acts like an inverse transform of the other transform. Finally, we give some remarks about certain relations between our sequential transforms and other well-known transforms on Ca,b[0,T].

  10. Real-time ed end-point Polymerase Chain Reaction per la quantizzazione del DNA di Citomegalovirus: confronto tra metodi e con il test per l’antigene pp65

    Directory of Open Access Journals (Sweden)

    Tiziano Allice

    2006-03-01

    Full Text Available Quantitave Polymerase Chain Reaction (PCR for Cytomegalovirus (CMV DNA provides highly sensitive and specific data for detecting CMV as well as monitoring the infection and determining the appropriate antiviral strategy.To determine the clinical application of a recently introduced real-time (RT PCR assay for CMV DNA quantitation in peripheral blood leukocytes (PBLs and defining its correlation with the commercial quantitative end-point (EP PCR method COBAS AMPLICOR CMV Monitor and pp65 antigen test. Sequential PBL samples (n=158 from 32 liver transplanted patients with CMV asymptomatic infection and positive for CMV DNA by EP-PCR were retrospectively analysed with RT-PCR and studied according to pp65 antigen levels. A good correlation was found between RT-PCR and pp65 antigen test (r=0.691 and between the two PCR assays (r=0.761. RT-PCR data were significantly higher in pre-emptive treated patients (those with >20 pp65+positive cells, median value: 3.8 log10 copies/500,000 PBLs than in not-treated ones (2.9 logs.According to pp65 levels of 0, 1-10, 11-20, 21-50, 51-100 and >100 positive cells/200,000 PBLs, median CMV DNA load by RT-PCR was 2.6, 3.0, 3.6, 4.0. 4.2 and 4.8, log10 copies/ 500,000 PBLs, respectively (EP-PCR CMV DNA levels: 2. 8, 2.9, 3.8, 3.7, 3.9 and 4.0 logs. For samples with >20 pp65+cells, that is above the level at which pre-emptive therapy was started, RT-PCR values were significantly higher than in groups with less than 20 pp65+cells, whereas EP-PCR values did not significantly differ and showed a slower progression rate. Dilutions of DNA from CMV AD169 strain were used to probe RT-PCR reproducibility (between and intra-assay variability < 2% and sensitivity (100% detection rate at 10 copies/reaction, 28.5% with EP-PCR. A significant improvement is coming from the introduction of RT-PCR to the study of CMV DNA dynamics in differently CMV infected patients due to a more reliable quantitation of CMV DNA for moderate and high

  11. A physical model study of the travel times and conversion point locations of P-SV converted waves in vertical transversely isotropic media

    Science.gov (United States)

    Tseng, C.

    2013-12-01

    In exploration seismology, subsurface medium commonly exhibits anisotropy, characterized by a vertical transversely isotropic (VTI) model. Due to the need of exploring small reservoirs in complex structures, the seismic exploration is extended to deal with anisotropic media. The P-S converted wave seismic exploration is a relatively inexpensive, broadly applicable, and effective way to obtain the S-wave information of the medium. In anisotropic traveltime analysis, the moveout curve of horizontal P-SV event can help to determine the ratio of the P- and SV-wave vertical velocities, the normal moveout (NMO) velocity of SV-waves, and the anisotropy parameters. The P-SV conversion point (CP) location is of great importance to P-SV data binning, NMO corrections and common conversion point (CCP) stacking, and the anisotropy has a more significant effect on the conversion point location than on the moveout. In this study, we attempt to inspect the theoretical non-hyperbolic moveout and CP equations for the P-SV waves reflected from a VTI layer by numerical calculations and physical modeling. We are also interested in visualizing the variations of the conversion point locations from a designed VTI medium. In traveltime analysis, the theoretical moveout curve is accurate up to offsets about one and a half times the reflector depth (x/z=1.5). However, the moveout curve computed by Fermat's principle fits well to the physical data. The CP locations of P-SV waves are similar to those calculated by Fermat's principle and theoretical CP equation, which are verified by the physical modeling.

  12. Clinical evaluation of synthetic aperture sequential beamforming ultrasound in patients with liver tumors

    DEFF Research Database (Denmark)

    Hansen, Peter Møller; Hemmsen, Martin Christian; Brandt, Andreas Hjelm

    2014-01-01

    Medical ultrasound imaging using synthetic aperture sequential beamforming (SASB) has for the first time been used for clinical patient scanning. Nineteen patients with cancer of the liver (hepatocellular carcinoma or colorectal liver metastases) were scanned simultaneously with conventional...

  13. Detection of sequential activation of left atrium and coronary sinus musculature in the general population

    Directory of Open Access Journals (Sweden)

    Masaki Ota, MD

    2016-12-01

    Conclusions: Far-field LA potentials are often recorded in the CS during sequential LA and CSM activation in the general population. The timing of LA potentials in CS recordings reflected the direction of conduction across the CSM.

  14. Dual-time-point {sup 18}F-FDG PET imaging for diagnosis of disease type and disease activity in patients with idiopathic interstitial pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Umeda, Yukihiro; Demura, Yoshiki; Ishizaki, Takeshi; Ameshima, Shingo [University of Fukui, Department of Respiratory Medicine, Yoshida-gun, Fukui (Japan); Miyamori, Isamu [University of Fukui, Third Department of Internal Medicine, Yoshida-gun, Fukui (Japan); Saito, Yuji [Fujita Health University, Division of Respirology and Allergology, Department of Internal Medicine, School of Medicine, Toyoake, Aichi (Japan); Tsuchida, Tatsuro [University of Fukui, Department of Radiology, Yoshida-gun, Fukui (Japan); Fujibayashi, Yasuhisa; Okazawa, Hidehiko [University of Fukui, Biomedical Imaging Research Center, Yoshida-gun, Fukui (Japan)

    2009-07-15

    Individual clinical courses of idiopathic interstitial pneumonia (IIP) are variable and difficult to predict because the pathology and disease activity are contingent, and chest computed tomography (CT) provides little information about disease activity. In this study, we applied dual-time-point [{sup 18}F]-fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) positron emission tomography (PET), commonly used for diagnosis of malignant tumours, to the differential diagnosis and prediction of disease progression in IIP patients. Fifty patients with IIP, including idiopathic pulmonary fibrosis (IPF, n = 21), non-specific interstitial pneumonia (NSIP, n = 18) and cryptogenic organizing pneumonia (COP, n = 11), underwent {sup 18}F-FDG PET examinations at two time points: scan 1 at 60 min (early imaging) and scan 2 at 180 min (delayed imaging) after {sup 18}F-FDG injection. The standardized uptake values (SUV) at the two points and the retention index (RI-SUV) calculated from them were evaluated and compared with chest CT findings, disease progression and disease types. To evaluate short-term disease progression, all patients were examined by pulmonary function test every 3 months for 1 year after {sup 18}F-FDG PET scanning. The early SUV for COP (2.47 {+-} 0.74) was significantly higher than that for IPF (0.99 {+-} 0.29, p = 0.0002) or NSIP (1.22 {+-} 0.44, p= 0.0025). When an early SUV cut-off value of 1.5 and greater was used to distinguish COP from IPF and NSIP, the sensitivity, specificity and accuracy were 90.9, 94.3 and 93.5%, respectively. The RI-SUV for IPF and NSIP lesions was significantly greater in patients with deteriorated pulmonary function after 1 year of follow-up (progressive group, 13.0 {+-} 8.9%) than in cases without deterioration during the 1-year observation period (stable group, -16.8 {+-} 5.9%, p < 0.0001). However, the early SUV for all IIP types provided no additional information of disease progression. When an RI-SUV cut-off value of 0% and greater was

  15. Real-time simulation of response to load variation for a ship reactor based on point-reactor double regions and lumped parameter model

    Energy Technology Data Exchange (ETDEWEB)

    Wang Qiao; Zhang De [Department of Nuclear Energy Science and Engineering, Naval University of Engineering, Wuhan 430033 (China); Chen Wenzhen, E-mail: Cwz2@21cn.com [Department of Nuclear Energy Science and Engineering, Naval University of Engineering, Wuhan 430033 (China); Chen Zhiyun [Department of Nuclear Energy Science and Engineering, Naval University of Engineering, Wuhan 430033 (China)

    2011-05-15

    Research highlights: > We calculate the variation of main parameters of the reactor core by the Simulink. > The Simulink calculation software (SCS) can deal well with the stiff problem. > The high calculation precision is reached with less time, and the results can be easily displayed. > The quick calculation of ship reactor transient can be achieved by this method. - Abstract: Based on the point-reactor double regions and lumped parameter model, while the nuclear power plant second loop load is increased or decreased quickly, the Simulink calculation software (SCS) is adopted to calculate the variation of main physical and thermal-hydraulic parameters of the reactor core. The calculation results are compared with those of three-dimensional simulation program. It is indicated that the SCS can deal well with the stiff problem of the point-reactor kinetics equations and the coupled problem of neutronics and thermal-hydraulics. The high calculation precision can be reached with less time, and the quick calculation of parameters of response to load disturbance for the ship reactor can be achieved. The clear image of the calculation results can also be displayed quickly by the SCS, which is very significant and important to guarantee the reactor safety operation.

  16. A systematic review of near real-time and point-of-care clinical decision support in anesthesia information management systems.

    Science.gov (United States)

    Simpao, Allan F; Tan, Jonathan M; Lingappan, Arul M; Gálvez, Jorge A; Morgan, Sherry E; Krall, Michael A

    2017-10-01

    Anesthesia information management systems (AIMS) are sophisticated hardware and software technology solutions that can provide electronic feedback to anesthesia providers. This feedback can be tailored to provide clinical decision support (CDS) to aid clinicians with patient care processes, documentation compliance, and resource utilization. We conducted a systematic review of peer-reviewed articles on near real-time and point-of-care CDS within AIMS using the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols. Studies were identified by searches of the electronic databases Medline and EMBASE. Two reviewers screened studies based on title, abstract, and full text. Studies that were similar in intervention and desired outcome were grouped into CDS categories. Three reviewers graded the evidence within each category. The final analysis included 25 articles on CDS as implemented within AIMS. CDS categories included perioperative antibiotic prophylaxis, post-operative nausea and vomiting prophylaxis, vital sign monitors and alarms, glucose management, blood pressure management, ventilator management, clinical documentation, and resource utilization. Of these categories, the reviewers graded perioperative antibiotic prophylaxis and clinical documentation as having strong evidence per the peer reviewed literature. There is strong evidence for the inclusion of near real-time and point-of-care CDS in AIMS to enhance compliance with perioperative antibiotic prophylaxis and clinical documentation. Additional research is needed in many other areas of AIMS-based CDS.

  17. Dual time point 2-deoxy-2-[18F]fluoro-D-glucose PET/CT: nodal staging in locally advanced breast cancer.

    Science.gov (United States)

    García Vicente, A M; Soriano Castrejón, A; Cruz Mora, M Á; Ortega Ruiperez, C; Espinosa Aunión, R; León Martín, A; González Ageitos, A; Van Gómez López, O

    2014-01-01

    To assess dual time point 2-deoxy-2-[(18)F]fluoro-D-glucose (18)(F)FDG PET-CT accuracy in nodal staging and in detection of extra-axillary involvement. Dual time point [(18)F] FDG PET/CT scan was performed in 75 patients. Visual and semiquantitative assessment of lymph nodes was performed. Semiquantitative measurement of SUV and ROC-analysis were carried out to calculate SUV(max) cut-off value with the best diagnostic performance. Axillary and extra-axillary lymph node chains were evaluated. Sensitivity and specificity of visual assessment was 87.3% and 75%, respectively. SUV(max) values with the best sensitivity were 0.90 and 0.95 for early and delayed PET, respectively. SUV(max) values with the best specificity were 1.95 and 2.75, respectively. Extra-axillary lymph node involvement was detected in 26.7%. FDG PET/CT detected extra-axillary lymph node involvement in one-fourth of the patients. Semiquantitative lymph node analysis did not show any advantage over the visual evaluation. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  18. Analytical representation for solution of the neutron point kinetics equation with time-dependent reactivity and free of the stiffness character

    International Nuclear Information System (INIS)

    Silva, Milena Wollmann da

    2013-01-01

    In this work, we report a genuine analytical representation for the solution of the neutron point kinetics equation free of the stiffness character, assuming that the reactivity is a continuous and sectionally continuous function of time. To this end, we initially cast the point kinetics equation in a first order linear differential equation. Next, we split the corresponding matrix as a sum of a diagonal matrix with a matrix, whose components contain the off-diagonal elements. Next, expanding the neutron density and the delayed neutron precursors concentrations in a truncated series, and replacing these expansions in the matrix equation, we come out with an equation, which allows to construct a recursive system, a first order matrix differential equation with source. The fundamental characteristic of this system relies on the fact that the corresponding matrix is diagonal, meanwhile the source term is written in terms of the matrix with the off-diagonal components. Further, the first equation of the recursive system has no source and satisfies the initial conditions. On the other hand, the remaining equations satisfy the null initial condition. Due to the diagonal feature of the matrix, we attain analytical solutions for these recursive equations. We also mention that we evaluate the results for any time value, without the analytical continuity because the purposed solution is free on the stiffness character. Finally, we present numerical simulations and comparisons against literature results, considering specific the applications for the following reactivity functions: constant, step, ramp, and sine. (author)

  19. Moving mesh generation with a sequential approach for solving PDEs

    DEFF Research Database (Denmark)

    In moving mesh methods, physical PDEs and a mesh equation derived from equidistribution of an error metrics (so-called the monitor function) are simultaneously solved and meshes are dynamically concentrated on steep regions (Lim et al., 2001). However, the simultaneous solution procedure...... a simple and robust moving mesh algorithm in one or multidimension. In this study, we propose a sequential solution procedure including two separate parts: prediction step to obtain an approximate solution to a next time level (integration of physical PDEs) and regriding step at the next time level (mesh...... generation and solution interpolation). Convection terms, which appear in physical PDEs and a mesh equation, are discretized by a WENO (Weighted Essentially Non-Oscillatory) scheme under the consrvative form. This sequential approach is to keep the advantages of robustness and simplicity for the static...

  20. Bidding in sequential electricity markets: The Nordic case

    DEFF Research Database (Denmark)

    Boomsma, Trine Krogh; Juul, Nina; Fleten, Stein-Erik

    2014-01-01

    problem as a multi-stage stochastic program. We investigate whether higher risk exposure can explain the hesitation, often observed in practice, to bid into the balancing market, even in cases of higher expected price levels. Furthermore, we quantify the gain from coordinated bidding, and by deriving......For electricity market participants trading in sequential markets with differences in price levels and risk exposure, coordinated bidding is highly relevant. We consider a Nordic power producer who engages in the day-ahead spot market and the near real-time balancing market. In both markets......, clearing prices and dispatched volumes are unknown at the time of bidding. However, in the balancing market, the agent faces an additional risk of not being dispatched. Taking into account the sequential clearing of these markets and the gradual realization of market prices, we formulate the bidding...

  1. Optimal Sequential Resource Sharing and Exchange in Multi-Agent Systems

    OpenAIRE

    Xiao, Yuanzhang

    2014-01-01

    Central to the design of many engineering systems and social networks is to solve the underlying resource sharing and exchange problems, in which multiple decentralized agents make sequential decisions over time to optimize some long-term performance metrics. It is challenging for the decentralized agents to make optimal sequential decisions because of the complicated coupling among the agents and across time. In this dissertation, we mainly focus on three important classes of multi-agent seq...

  2. Efficacy of premixed versus sequential administration of ...

    African Journals Online (AJOL)

    sequential administration in separate syringes on block characteristics, haemodynamic parameters, side effect profile and postoperative analgesic requirement. Trial design: This was a prospective, randomised clinical study. Method: Sixty orthopaedic patients scheduled for elective lower limb surgery under spinal ...

  3. Sequential Detection of Thermophilic Lipase and Protease by Zymography.

    Science.gov (United States)

    Kurz, Liliana; Hernández, Zully; Contreras, Lellys M; Wilkesman, Jeff

    2017-01-01

    Lipase and protease present in cell-free fractions of thermophilic Bacillus sp. cultures were analyzed by polyacrylamide gel (PAG) electrophoresis. After run, the gel is electrotransferred to another PAG copolymerized with glycerol tributyrate, olive oil, and gelatin. This multi-substrate gel was incubated first for lipase detection, until bands appeared, and then stained with Coomassie for protease detection. Advantages of this sequential procedure are the detection of two different enzyme activities on a single PAG, beside time and resource saving.

  4. Models of sequential decision making in consumer lending

    OpenAIRE

    Kanshukan Rajaratnam; Peter A. Beling; George A. Overstreet

    2016-01-01

    Abstract In this paper, we introduce models of sequential decision making in consumer lending. From the definition of adverse selection in static lending models, we show that homogenous borrowers take-up offers at different instances of time when faced with a sequence of loan offers. We postulate that bounded rationality and diverse decision heuristics used by consumers drive the decisions they make about credit offers. Under that postulate, we show how observation of early decisions in a seq...

  5. MUF residuals tested by a sequential test with power one

    International Nuclear Information System (INIS)

    Sellinschegg, D.; Bicking, U.

    1983-01-01

    Near-real-time material accountancy is an ongoing safeguards development to extend the current capability of IAEA safeguards. The evaluation of the observed ''Material Unaccounted For'' (MUF) time series is an important part in a near-real-time material accountancy regime. The maximum capability of a sequential data evaluation procedure is demonstrated by applying this procedure to the material balance area of the chemical separation process of a reference reprocessing facility with a throughput of 1000 tonnes heavy metal per year, as an example. It is shown that, compared to a conventional material accountancy approach, the detection time as well as the detection probability is significantly improved. (author)

  6. Structural Consistency, Consistency, and Sequential Rationality.

    OpenAIRE

    Kreps, David M; Ramey, Garey

    1987-01-01

    Sequential equilibria comprise consistent beliefs and a sequentially ra tional strategy profile. Consistent beliefs are limits of Bayes ratio nal beliefs for sequences of strategies that approach the equilibrium strategy. Beliefs are structurally consistent if they are rationaliz ed by some single conjecture concerning opponents' strategies. Consis tent beliefs are not necessarily structurally consistent, notwithstan ding a claim by Kreps and Robert Wilson (1982). Moreover, the spirit of stru...

  7. A Calibrated Test-Set for Measurement of Access-Point Time Specifications in Hybrid Wired/Wireless Industrial Communication †

    Directory of Open Access Journals (Sweden)

    Federico Tramarin

    2018-05-01

    Full Text Available In factory automation and process control systems, hybrid wired/wireless networks are often deployed to connect devices of difficult reachability such as those mounted on mobile equipment. A widespread implementation of these networks makes use of Access Points (APs to implement wireless extensions of Real-Time Ethernet (RTE networks via the IEEE 802.11 Wireless LAN (WLAN. Unfortunately, APs may introduce random delays in frame forwarding, mainly related to their internal behavior (e.g., queue management, processing times, that clearly impact the overall worst case execution time of real-time tasks involved in industrial process control systems. As a consequence, the knowledge of such delays becomes a crucial design parameter, and their estimation is definitely of utter importance. In this scenario, the paper presents an original and effective method to measure the aforementioned delays introduced by APs, exploiting a hybrid loop-back link and a simple, yet accurate set-up with moderate instrumentation requirements. The proposed method, which requires an initial calibration phase by means of a reference AP, has been successfully tested on some commercial APs to prove its effectiveness. The proposed measurement procedure is proven to be general and, as such, can be profitably adopted in even different scenarios.

  8. Cardiac EASE (Ensuring Access and Speedy Evaluation) – the impact of a single-point-of-entry multidisciplinary outpatient cardiology consultation program on wait times in Canada

    Science.gov (United States)

    Bungard, Tammy J; Smigorowsky, Marcie J; Lalonde, Lucille D; Hogan, Terry; Doliszny, Katharine M; Gebreyesus, Ghirmay; Garg, Sipi; Archer, Stephen L

    2009-01-01

    BACKGROUND: Universal access to health care is valued in Canada but increasing wait times for services (eg, cardiology consultation) raise safety questions. Observations suggest that deficiencies in the process of care contribute to wait times. Consequently, an outpatient clinic was designed for Ensuring Access and Speedy Evaluation (Cardiac EASE) in a university group practice, providing cardiac consultative services for northern Alberta. Cardiac EASE has two components: a single-point-of-entry intake service (prospective testing using physician-approved algorithms and previsit triage) and a multidisciplinary clinic (staffed by cardiologists, nurse practitioners and doctoral-trained pharmacists). OBJECTIVES: It was hypothesized that Cardiac EASE would reduce the time to initial consultation and a definitive diagnosis, and also increase the referral capacity. METHODS: The primary and secondary outcomes were time from referral to initial consultation, and time to achieve a definitive diagnosis and management plan, respectively. A conventionally managed historical control group (three-month pre-EASE period in 2003) was compared with the EASE group (2004 to 2006). The conventional referral mechanism continued concurrently with EASE. RESULTS: A comparison between pre-EASE (n=311) and EASE (n=3096) revealed no difference in the mean (± SD) age (60±16 years), sex (55% and 52% men, respectively) or reason for referral, including chest pain (31% and 40%, respectively) and arrhythmia (27% and 29%, respectively). Cardiac EASE reduced the time to initial cardiac consultation (from 71±45 days to 33±19 days) and time to a definitive diagnosis (from 120±86 days to 51±58 days) (P<0.0001). The annual number of new referrals increased from 1512 in 2002 to 2574 in 2006 due to growth in the Cardiac EASE clinic. The number of patients seen through the conventional referral mechanism and their wait times remained constant during the study period. CONCLUSIONS: Cardiac EASE reduced

  9. The dynamics of smoking-related disturbed methylation: a two time-point study of methylation change in smokers, non-smokers and former smokers.

    Science.gov (United States)

    Wilson, Rory; Wahl, Simone; Pfeiffer, Liliane; Ward-Caviness, Cavin K; Kunze, Sonja; Kretschmer, Anja; Reischl, Eva; Peters, Annette; Gieger, Christian; Waldenberger, Melanie

    2017-10-18

    The evidence for epigenome-wide associations between smoking and DNA methylation continues to grow through cross-sectional studies. However, few large-scale investigations have explored the associations using observations for individuals at multiple time-points. Here, through the use of the Illumina 450K BeadChip and data collected at two time-points separated by approximately 7 years, we investigate changes in methylation over time associated with quitting smoking or remaining a former smoker, and those associated with continued smoking. Our results indicate that after quitting smoking the most rapid reversion of altered methylation occurs within the first two decades, with reversion rates related to the initial differences in methylation. For 52 CpG sites, the change in methylation from baseline to follow-up is significantly different for former smokers relative to the change for never smokers (lowest p-value 3.61 x 10 -39 for cg26703534, gene AHRR). Most of these sites' respective regions have been previously implicated in smoking-associated diseases. Despite the early rapid change, dynamism of methylation appears greater in former smokers vs never smokers even four decades after cessation. Furthermore, our study reveals the heterogeneous effect of continued smoking: the methylation levels of some loci further diverge between smokers and non-smokers, while others re-approach. Though intensity of smoking habit appears more significant than duration, results remain inconclusive. This study improves the understanding of the dynamic link between cigarette smoking and methylation, revealing the continued fluctuation of methylation levels decades after smoking cessation and demonstrating that continuing smoking can have an array of effects. The results can facilitate insights into the molecular mechanisms behind smoking-induced disturbed methylation, improving the possibility for development of biomarkers of past smoking behavior and increasing the understanding of

  10. Time-Lapse Analysis of Methane Quantity in the Mary Lee Group of Coal Seams Using Filter-Based Multiple-Point Geostatistical Simulation.

    Science.gov (United States)

    Karacan, C Özgen; Olea, Ricardo A

    2013-08-01

    Coal seam degasification and its success are important for controlling methane, and thus for the health and safety of coal miners. During the course of degasification, properties of coal seams change. Thus, the changes in coal reservoir conditions and in-place gas content as well as methane emission potential into mines should be evaluated by examining time-dependent changes and the presence of major heterogeneities and geological discontinuities in the field. In this work, time-lapsed reservoir and fluid storage properties of the New Castle coal seam, Mary Lee/Blue Creek seam, and Jagger seam of Black Warrior Basin, Alabama, were determined from gas and water production history matching and production forecasting of vertical degasification wellbores. These properties were combined with isotherm and other important data to compute gas-in-place (GIP) and its change with time at borehole locations. Time-lapsed training images (TIs) of GIP and GIP difference corresponding to each coal and date were generated by using these point-wise data and Voronoi decomposition on the TI grid, which included faults as discontinuities for expansion of Voronoi regions. Filter-based multiple-point geostatistical simulations, which were preferred in this study due to anisotropies and discontinuities in the area, were used to predict time-lapsed GIP distributions within the study area. Performed simulations were used for mapping spatial time-lapsed methane quantities as well as their uncertainties within the study area. The systematic approach presented in this paper is the first time in literature that history matching, TIs of GIPs and filter simulations are used for degasification performance evaluation and for assessing GIP for mining safety. Results from this study showed that using production history matching of coalbed methane wells to determine time-lapsed reservoir data could be used to compute spatial GIP and representative GIP TIs generated through Voronoi decomposition

  11. Night-time heart rate cut-off point definition by resting office tachycardia in untreated hypertensive patients: data of the Spanish ABPM registry.

    Science.gov (United States)

    Vinyoles, Ernest; de la Sierra, Alejandro; Roso, Albert; de la Cruz, Juan J; Gorostidi, Manuel; Segura, Julián; Banegas, José R; Martell-Claros, Nieves; Ruilope, Luís M

    2014-05-01

    Epidemiological studies have shown that an elevated resting heart rate (HR) is a risk factor for both total and cardiovascular mortality. Our aim was to estimate the night-time HR cut-off point that best predicts cardiovascular risk office tachycardia in hypertensive patients. Untreated hypertensive patients without concomitant cardiovascular diseases were included. Office and ambulatory HRs were measured. Cardiovascular risk office tachycardia was defined by office HR at least 85 beats per minute (bpm). Different night-time HR cut-offs were estimated by receiver operating characteristic curve analyses to predict cardiovascular risk office tachycardia. The best cut-off was selected on the basis of its combined sensitivity and specificity. A total of 32 569 hypertensive patients were included: 46.5% women, mean age (SD) 52 (14) years, office blood pressure 146 (16)/89 (11) mmHg, diabetes 10.3%, smoking 19.2%, BMI 29 (6.8) kg/m, office HR 77 (11.2) bpm, and night-time HR 64.9 (9.3) bpm. A total of 7070 (21.7%) patients were found to have cardiovascular risk office tachycardia. The night-time HR value that better predicted cardiovascular risk office tachycardia was more than 66 bpm. In comparison with patients with night HR below this value, those with night-time tachycardia were predominantly women, younger, with higher ambulatory blood pressure, greater BMI, and higher prevalence of diabetes and smoking. All comparisons were statistically significant (P less than 0.001). A mean night-time HR more than 66 bpm is a good predictor of cardiovascular risk office tachycardia in untreated hypertensive patients and could be considered a variable associated with an increased cardiovascular risk.

  12. A Walnut-Enriched Diet Reduces Lipids in Healthy Caucasian Subjects, Independent of Recommended Macronutrient Replacement and Time Point of Consumption: a Prospective, Randomized, Controlled Trial.

    Science.gov (United States)

    Bamberger, Charlotte; Rossmeier, Andreas; Lechner, Katharina; Wu, Liya; Waldmann, Elisa; Stark, Renée G; Altenhofer, Julia; Henze, Kerstin; Parhofer, Klaus G

    2017-10-06

    Studies indicate a positive association between walnut intake and improvements in plasma lipids. We evaluated the effect of an isocaloric replacement of macronutrients with walnuts and the time point of consumption on plasma lipids. We included 194 healthy subjects (134 females, age 63 ± 7 years, BMI 25.1 ± 4.0 kg/m²) in a randomized, controlled, prospective, cross-over study. Following a nut-free run-in period, subjects were randomized to two diet phases (8 weeks each). Ninety-six subjects first followed a walnut-enriched diet (43 g walnuts/day) and then switched to a nut-free diet. Ninety-eight subjects followed the diets in reverse order. Subjects were also randomized to either reduce carbohydrates ( n = 62), fat ( n = 65), or both ( n = 67) during the walnut diet, and instructed to consume walnuts either as a meal or as a snack. The walnut diet resulted in a significant reduction in fasting cholesterol (walnut vs. -8.5 ± 37.2 vs. -1.1 ± 35.4 mg/dL; p = 0.002), non-HDL cholesterol (-10.3 ± 35.5 vs. -1.4 ± 33.1 mg/dL; p ≤ 0.001), LDL-cholesterol (-7.4 ± 32.4 vs. -1.7 ± 29.7 mg/dL; p = 0.029), triglycerides (-5.0 ± 47.5 vs. 3.7 ± 48.5 mg/dL; p = 0.015) and apoB (-6.7 ± 22.4 vs. -0.5 ± 37.7; p ≤ 0.001), while HDL-cholesterol and lipoprotein (a) did not change significantly. Neither macronutrient replacement nor time point of consumption significantly affected the effect of walnuts on lipids. Thus, 43 g walnuts/d improved the lipid profile independent of the recommended macronutrient replacement and the time point of consumption.

  13. Sequential acquisition of mutations in myelodysplastic syndromes.

    Science.gov (United States)

    Makishima, Hideki

    2017-01-01

    Recent progress in next-generation sequencing technologies allows us to discover frequent mutations throughout the coding regions of myelodysplastic syndromes (MDS), potentially providing us with virtually a complete spectrum of driver mutations in this disease. As shown by many study groups these days, such driver mutations are acquired in a gene-specific fashion. For instance, DDX41 mutations are observed in germline cells long before MDS presentation. In blood samples from healthy elderly individuals, somatic DNMT3A and TET2 mutations are detected as age-related clonal hematopoiesis and are believed to be a risk factor for hematological neoplasms. In MDS, mutations of genes such as NRAS and FLT3, designated as Type-1 genes, may be significantly associated with leukemic evolution. Another type (Type-2) of genes, including RUNX1 and GATA2, are related to progression from low-risk to high-risk MDS. Overall, various driver mutations are sequentially acquired in MDS, at a specific time, in either germline cells, normal hematopoietic cells, or clonal MDS cells.

  14. An Estimation of the Likelihood of Significant Eruptions During 2000-2009 Using Poisson Statistics on Two-Point Moving Averages of the Volcanic Time Series

    Science.gov (United States)

    Wilson, Robert M.

    2001-01-01

    Since 1750, the number of cataclysmic volcanic eruptions (volcanic explosivity index (VEI)>=4) per decade spans 2-11, with 96 percent located in the tropics and extra-tropical Northern Hemisphere. A two-point moving average of the volcanic time series has higher values since the 1860's than before, being 8.00 in the 1910's (the highest value) and 6.50 in the 1980's, the highest since the 1910's peak. Because of the usual behavior of the first difference of the two-point moving averages, one infers that its value for the 1990's will measure approximately 6.50 +/- 1, implying that approximately 7 +/- 4 cataclysmic volcanic eruptions should be expected during the present decade (2000-2009). Because cataclysmic volcanic eruptions (especially those having VEI>=5) nearly always have been associated with short-term episodes of global cooling, the occurrence of even one might confuse our ability to assess the effects of global warming. Poisson probability distributions reveal that the probability of one or more events with a VEI>=4 within the next ten years is >99 percent. It is approximately 49 percent for an event with a VEI>=5, and 18 percent for an event with a VEI>=6. Hence, the likelihood that a climatically significant volcanic eruption will occur within the next ten years appears reasonably high.

  15. Fixed Points

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 5. Fixed Points - From Russia with Love - A Primer of Fixed Point Theory. A K Vijaykumar. Book Review Volume 5 Issue 5 May 2000 pp 101-102. Fulltext. Click here to view fulltext PDF. Permanent link:

  16. Tipping Point

    Medline Plus

    Full Text Available ... OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point ... 24 hours a day. For young children whose home is a playground, it’s the best way to ...

  17. Tipping Point

    Medline Plus

    Full Text Available ... 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ...

  18. Evaluation of articular cartilage in patients with femoroacetabular impingement (FAI) using T2* mapping at different time points at 3.0 Tesla MRI: a feasibility study

    International Nuclear Information System (INIS)

    Apprich, S.; Mamisch, T.C.; Welsch, G.H.; Bonel, H.; Siebenrock, K.A.; Dudda, M.; Kim, Y.J.; Trattnig, S.

    2012-01-01

    To define the feasibility of utilizing T2* mapping for assessment of early cartilage degeneration prior to surgery in patients with symptomatic femoroacetabular impingement (FAI), we compared cartilage of the hip joint in patients with FAI and healthy volunteers using T2* mapping at 3.0 Tesla over time. Twenty-two patients (13 females and 9 males; mean age 28.1 years) with clinical signs of FAI and Toennis grade ≤ 1 on anterior-posterior x-ray and 35 healthy age-matched volunteers were examined at a 3 T MRI using a flexible body coil. T2* maps were calculated from sagittal- and coronal-oriented gradient-multi-echo sequences using six echoes (TR 125, TE 4.41/8.49/12.57/16.65/20.73/24.81, scan time 4.02 min), both measured at beginning and end of the scan (45 min time span between measurements). Region of interest analysis was manually performed on four consecutive slices for superior and anterior cartilage. Mean T2* values were compared among patients and volunteers, as well as over time using analysis of variance and Student's t-test. Whereas quantitative T2* values for the first measurement did not reveal significant differences between patients and volunteers, either for sagittal (p = 0.644) or coronal images (p = 0.987), at the first measurement, a highly significant difference (p ≤ 0.004) was found for both measurements with time after unloading of the joint. Over time we found decreasing mean T2* values for patients, in contrast to increasing mean T2* relaxation times in volunteers. The study proved the feasibility of utilizing T2* mapping for assessment of early cartilage degeneration in the hip joint in FAI patients at 3 Tesla to predict possible success of joint-preserving surgery. However, we suggest the time point for measuring T2* as an MR biomarker for cartilage and the changes in T2* over time to be of crucial importance for designing an MR protocol in patients with FAI. (orig.)

  19. Evaluation of articular cartilage in patients with femoroacetabular impingement (FAI) using T2* mapping at different time points at 3.0 Tesla MRI: a feasibility study.

    Science.gov (United States)

    Apprich, S; Mamisch, T C; Welsch, G H; Bonel, H; Siebenrock, K A; Kim, Y-J; Trattnig, S; Dudda, M

    2012-08-01

    To define the feasibility of utilizing T2* mapping for assessment of early cartilage degeneration prior to surgery in patients with symptomatic femoroacetabular impingement (FAI), we compared cartilage of the hip joint in patients with FAI and healthy volunteers using T2* mapping at 3.0 Tesla over time. Twenty-two patients (13 females and 9 males; mean age 28.1 years) with clinical signs of FAI and Tönnis grade ≤ 1 on anterior-posterior x-ray and 35 healthy age-matched volunteers were examined at a 3 T MRI using a flexible body coil. T2* maps were calculated from sagittal- and coronal-oriented gradient-multi-echo sequences using six echoes (TR 125, TE 4.41/8.49/12.57/16.65/20.73/24.81, scan time 4.02 min), both measured at beginning and end of the scan (45 min time span between measurements). Region of interest analysis was manually performed on four consecutive slices for superior and anterior cartilage. Mean T2* values were compared among patients and volunteers, as well as over time using analysis of variance and Student's t-test. Whereas quantitative T2* values for the first measurement did not reveal significant differences between patients and volunteers, either for sagittal (p = 0.644) or coronal images (p = 0.987), at the first measurement, a highly significant difference (p ≤ 0.004) was found for both measurements with time after unloading of the joint. Over time we found decreasing mean T2* values for patients, in contrast to increasing mean T2* relaxation times in volunteers. The study proved the feasibility of utilizing T2* mapping for assessment of early cartilage degeneration in the hip joint in FAI patients at 3 Tesla to predict possible success of joint-preserving surgery. However, we suggest the time point for measuring T2* as an MR biomarker for cartilage and the changes in T2* over time to be of crucial importance for designing an MR protocol in patients with FAI.

  20. Assessing the Influence of Land Use and Land Cover Datasets with Different Points in Time and Levels of Detail on Watershed Modeling in the North River Watershed, China

    Directory of Open Access Journals (Sweden)

    Jinliang Huang

    2012-12-01

    Full Text Available Land use and land cover (LULC information is an important component influencing watershed modeling with regards to hydrology and water quality in the river basin. In this study, the sensitivity of the Soil and Water Assessment Tool (SWAT model to LULC datasets with three points in time and three levels of detail was assessed in a coastal subtropical watershed located in Southeast China. The results showed good agreement between observed and simulated values for both monthly and daily streamflow and monthly NH4+-N and TP loads. Three LULC datasets in 2002, 2007 and 2010 had relatively little influence on simulated monthly and daily streamflow, whereas they exhibited greater effects on simulated monthly NH4+-N and TP loads. When using the two LULC datasets in 2007 and 2010 compared with that in 2002, the relative differences in predicted monthly NH4+-N and TP loads were −11.0 to −7.8% and −4.8 to −9.0%, respectively. There were no significant differences in simulated monthly and daily streamflow when using the three LULC datasets with ten, five and three categories. When using LULC datasets from ten categories compared to five and three categories, the relative differences in predicted monthly NH4+-N and TP loads were −6.6 to −6.5% and −13.3 to −7.3%, respectively. Overall, the sensitivity of the SWAT model to LULC datasets with different points in time and levels of detail was lower in monthly and daily streamflow simulation than in monthly NH4+-N and TP loads prediction. This research provided helpful insights into the influence of LULC datasets on watershed modeling.

  1. Keratocyte apoptosis and not myofibroblast differentiation mark the graft/host interface at early time-points post-DSAEK in a cat model.

    Directory of Open Access Journals (Sweden)

    Adam J Weis

    Full Text Available To evaluate myofibroblast differentiation as an etiology of haze at the graft-host interface in a cat model of Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK.DSAEK was performed on 10 eyes of 5 adult domestic short-hair cats. In vivo corneal imaging with slit lamp, confocal, and optical coherence tomography (OCT were performed twice weekly. Cats were sacrificed and corneas harvested 4 hours, and 2, 4, 6, and 9 days post-DSAEK. Corneal sections were stained with the TUNEL method and immunohistochemistry was performed for α-smooth muscle actin (α-SMA and fibronectin with DAPI counterstain.At all in vivo imaging time-points, corneal OCT revealed an increase in backscatter of light and confocal imaging revealed an acellular zone at the graft-host interface. At all post-mortem time-points, immunohistochemistry revealed a complete absence of α-SMA staining at the graft-host interface. At 4 hours, extracellular fibronectin staining was identified along the graft-host interface and both fibronectin and TUNEL assay were positive within adjacent cells extending into the host stroma. By day 2, fibronectin and TUNEL staining diminished and a distinct acellular zone was present in the region of previously TUNEL-positive cells.OCT imaging consistently showed increased reflectivity at the graft-host interface in cat corneas in the days post-DSAEK. This was not associated with myofibroblast differentiation at the graft-host interface, but rather with apoptosis and the development of a subsequent acellular zone. The roles of extracellular matrix changes and keratocyte cell death and repopulation should be investigated further as potential contributors to the interface optical changes.

  2. Relationships between Endogenous Plasma Biomarkers of Constitutive Cytochrome P450 3A Activity and Single-Time-Point Oral Midazolam Microdose Phenotype in Healthy Subjects.

    Science.gov (United States)

    Woolsey, Sarah J; Beaton, Melanie D; Choi, Yun-Hee; Dresser, George K; Gryn, Steven E; Kim, Richard B; Tirona, Rommel G

    2016-04-01

    Due to high basal interindividual variation in cytochrome P450 3A (CYP3A) activity and susceptibility to drug interactions, there has been interest in the application of efficient probe drug phenotyping strategies, as well as endogenous biomarkers for assessment of in vivo CYP3A activity. The biomarkers 4β-hydroxycholesterol (4βHC) and 6β-hydroxycortisol (6βHCL) are sensitive to CYP3A induction and inhibition. However, their utility for the assessment of constitutive CYP3A activity remains uncertain. We investigated whether endogenous plasma biomarkers (4βHC and 6βHCL) are associated with basal CYP3A metabolic activity in healthy subjects assessed by a convenient single-time-point oral midazolam (MDZ) phenotyping strategy. Plasma 4βHC and 6βHCL metabolic ratios (MRs) were analysed in 51 healthy adult participants. CYP3A activity was determined after administration of an oral MDZ microdose (100 μg). Simple linear and multiple linear regression analyses were performed to assess relationships between MDZ oral clearance, biomarkers and subject covariates. Among study subjects, basal MDZ oral clearance, 4βHC and 6βHCL MRs ranged 6.5-, 10- and 13-fold, respectively. Participant age and alcohol consumption were negatively associated with MDZ oral clearance (p = 0.03 and p = 0.045, respectively), while weight and female sex were associated with lower plasma 4βHC MR (p = 0.0003 and p = 0.032, respectively). Neither 4βHC nor 6βHCL MRs were associated with MDZ oral clearance. Plasma 4βHC and 6βHCL MRs do not relate to MDZ single-time-point metabolic phenotype in the assessment of constitutive CYP3A activity among healthy individuals. © 2015 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  3. The time point of β-catenin knockout in hepatocytes determines their response to xenobiotic activation of the constitutive androstane receptor

    International Nuclear Information System (INIS)

    Ganzenberg, Katrin; Singh, Yasmin; Braeuning, Albert

    2013-01-01

    The constitutive androstane receptor (CAR) controls the expression of drug-metabolizing enzymes and regulates hepatocyte proliferation. Studies with transgenic mice with an early postnatal conditional hepatocyte-specific knockout of the β-catenin gene Ctnnb1 revealed that β-catenin deficiency decreases the magnitude of induction of drug-metabolizing enzymes by CAR activators, abrogates zonal differences in the hepatocytes’ susceptibility to these compounds, and impacts on hepatocyte proliferation. These data, however, do not allow distinguishing between effects caused by β-catenin deficiency during postnatal liver development and acute effects of β-catenin deficiency in the adult animal at the time point of CAR activation. Therefore, CAR activation was now studied in a different mouse model allowing for the hepatocyte-specific knockout of β-catenin in adult mice. Treatment of these mice with 3 mg/kg body weight of the model CAR activator 1,4-bis-[2-(3,5-dichloropyridyloxy)]benzene (TCPOBOP) confirmed previous findings related to the coordinate regulation of drug metabolism by β-catenin and CAR. More importantly, the present study clarified that the impact of β-catenin signaling on CAR-mediated enzyme induction in the liver is not merely due to developmental defects caused by a postnatal lack of β-catenin, but depends on the presence of β-catenin at the time point of xenobiotic treatment. The study also revealed interesting differences between the two mouse models: hepatic zonation of TCPOBOP-dependent induction of drug-metabolizing enzymes was restored in mice with late knockout of β-catenin, and the strong proliferative response of female mice was exclusively abolished when using animals with a late β-catenin knockout. This suggests a β-catenin-dependent postnatal priming of hepatocytes during postnatal liver development, later affecting the proliferative response of adult animals to CAR-activating xenobiotics

  4. Optimal time-point for 68Ga-PSMA-11 PET/CT imaging in assessment of prostate cancer: feasibility of sterile cold-kit tracer preparation?

    Science.gov (United States)

    Beheshti, Mohsen; Paymani, Zeinab; Brilhante, Joana; Geinitz, Hans; Gehring, Daniela; Leopoldseder, Thomas; Wouters, Ludovic; Pirich, Christian; Loidl, Wolfgang; Langsteger, Werner

    2018-07-01

    In this prospective study, we evaluated the optimal time-point for 68 Ga-PSMA-11 PET/CT acquisition in the assessment of prostate cancer. We also examined, for the first time the feasibility of tracer production using a PSMA-11 sterile cold-kit in the clinical workflow of PET/CT centres. Fifty prostate cancer patients (25 staging, 25 biochemical recurrence) were enrolled in this study. All patients received an intravenous dose of 2.0 MBq/kg body weight 68 Ga-PSMA-11 prepared using a sterile cold kit (ANMI SA, Liege, Belgium), followed by an early (20 min after injection) semi-whole-body PET/CT scan and a standard-delay (100 min after injection) abdominopelvic PET/CT scan. The detection rates with 68 Ga-PSMA-11 were compared between the two acquisitions. The pattern of physiological background activity and tumour to background ratio were also analysed. The total preparation time was reduced to 5 min using the PSMA-11 sterile cold kit, which improved the final radionuclide activity by about 30% per single 68 Ge/ 68 Ga generator elution. Overall, 158 pathological lesions were analysed in 45 patients (90%) suggestive of malignancy on both (early and standard-delay) 68 Ga-PSMA PET/CT images. There was a significant (p PET/CT imaging seems to provide a detection rate comparable with that of standard-delay imaging. Furthermore, the shorter preparation time using the 68 Ga-PSMA-11 sterile cold kit and promising value of early PET/CT scanning could allow tailoring of imaging protocols which may reduce the costs and improve the time efficiency in PET/CT centres.

  5. Real-Time Spaceborne Synthetic Aperture Radar Float-Point Imaging System Using Optimized Mapping Methodology and a Multi-Node Parallel Accelerating Technique

    Science.gov (United States)

    Li, Bingyi; Chen, Liang; Yu, Wenyue; Xie, Yizhuang; Bian, Mingming; Zhang, Qingjun; Pang, Long

    2018-01-01

    With the development of satellite load technology and very large-scale integrated (VLSI) circuit technology, on-board real-time synthetic aperture radar (SAR) imaging systems have facilitated rapid response to disasters. A key goal of the on-board SAR imaging system design is to achieve high real-time processing performance under severe size, weight, and power consumption constraints. This paper presents a multi-node prototype system for real-time SAR imaging processing. We decompose the commonly used chirp scaling (CS) SAR imaging algorithm into two parts according to the computing features. The linearization and logic-memory optimum allocation methods are adopted to realize the nonlinear part in a reconfigurable structure, and the two-part bandwidth balance method is used to realize the linear part. Thus, float-point SAR imaging processing can be integrated into a single Field Programmable Gate Array (FPGA) chip instead of relying on distributed technologies. A single-processing node requires 10.6 s and consumes 17 W to focus on 25-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384. The design methodology of the multi-FPGA parallel accelerating system under the real-time principle is introduced. As a proof of concept, a prototype with four processing nodes and one master node is implemented using a Xilinx xc6vlx315t FPGA. The weight and volume of one single machine are 10 kg and 32 cm × 24 cm × 20 cm, respectively, and the power consumption is under 100 W. The real-time performance of the proposed design is demonstrated on Chinese Gaofen-3 stripmap continuous imaging. PMID:29495637

  6. Habitat use by mountain nyala Tragelaphus buxtoni determined using stem bite diameters at point of browse, bite rates, and time budgets in the Bale Mountains National Park, Ethiopia

    Directory of Open Access Journals (Sweden)

    Solomon A. TADESSE, Burt P. KOTLER

    2013-12-01

    Full Text Available We studied the habitat use of mountain nyala Tragelaphus buxtoni in the northern edge of the Bale Mountains National Park, Ethiopia. The aims of this study were to: (1 measure and quantify habitat-specific stem bite diameters of mountain nyala foraging on common natural plant species in two major habitat types (i.e. grasslands versus woodlands, and (2 quantify the bite rates (number of bites per minute and the activity time budgets of mountain nyala as functions of habitat type and sex-age category. We randomly laid out three transects in each habitat type. Following each transect, through focal animal observations, we assessed and quantified stem diameters at point of browse (dpb, bite rates, and time budgets of mountain nyala in grasslands versus woodlands. Stem dpb provide a measure of natural giving-up densities (GUDs and can be used to assess foraging costs and efficiencies, with greater stem dpb corresponding to lower costs and greater efficiencies. The results showed that stem dpb, bite rates, induced vigilance, and proportion of time spent in feeding differed between habitats. In particular, mountain nyala had greater stem dpb, higher bite rates, and spent a greater proportion of their time in feeding and less in induced vigilance in the grasslands. In addition, adult females had the highest bite rates, and the browse species Solanum marginatum had the greatest stem dpb. Generally, grasslands provide the mountain nyala with several advantages over the woodlands, including offering lower foraging costs, greater safety, and more time for foraging. The study advocates how behavioural indicators and natural GUDs are used to examine the habitat use of the endangered mountain nyala through applying non-invasive techniques. We conclude that the resulting measures are helpful for guiding conservation and management efforts and could be applicable to a number of endangered wildlife species including the mountain nyala [Current Zoology 59 (6 : 707

  7. Laboratory Tests Turnaround Time in Outpatient and Emergency Patients in Nigeria: Results of A Physician Survey on Point of Care Testing

    Directory of Open Access Journals (Sweden)

    Bolodeoku J

    2017-05-01

    Full Text Available Laboratory analytical turnaround time is a well-recognised indicator of how well a laboratory is performing and is sometimes regarded as the benchmark for laboratory performance. Methods: Total 104 doctors in public and private health institutions in Nigeria, spread across all six geo-political zones participated in survey requesting information on their experience with laboratory turnaround times in emergency situations (emergency room, special care baby unit, intensive care unit, dialysis unit and outpatient situations (general medicine and diabetes. Results: The average turnaround time in hours was 5.12, 8.35, 7.32 and 8.33 for the emergency room, special care baby unit, intensive care unit and dialysis unit, respectively. For the outpatient situations, the average turnaround time in hours was 10.74 and 15.70 hours for the diabetes and general medical outpatients. The median range (hours and modal range (hours for: the emergency room was 2-4 and <2; the special care baby unit was 4-8 and 4-8; the intensive care unit was 2-4 and 2-4; the dialysis unit was 4-8 and 4-8. The median range (hours and modal range (hours for: the general outpatient clinic was 12-24 and 12-24; the diabetic clinic was 4-8 and 12-24 hours. Conclusion: These turnaround time results are quite consistent with published data from other countries. However, there is some measure of improvement that is required in some areas to reduce the laboratory turnaround in the emergency situations. This could be overcome with the introduction of more point of care testing devices into emergency units.

  8. Programme for test generation for combinatorial and sequential systems

    International Nuclear Information System (INIS)

    Tran Huy Hoan

    1973-01-01

    This research thesis reports the computer-assisted search for tests aimed at failure detection in combinatorial and sequential logic circuits. As he wants to deal with complex circuits with many modules such as those met in large scale integrated circuits (LSI), the author used propagation paths. He reports the development of a method which is valid for combinatorial systems and for several sequential circuits comprising elementary logic modules and JK and RS flip-flops. This method is developed on an IBM 360/91 computer in PL/1 language. The used memory space is limited and adjustable with respect to circuit dimension. Computing time is short when compared to that needed by other programmes. The solution is practical and efficient for failure test and localisation

  9. Comparisons of memory for nonverbal auditory and visual sequential stimuli.

    Science.gov (United States)

    McFarland, D J; Cacace, A T

    1995-01-01

    Properties of auditory and visual sensory memory were compared by examining subjects' recognition performance of randomly generated binary auditory sequential frequency patterns and binary visual sequential color patterns within a forced-choice paradigm. Experiment 1 demonstrated serial-position effects in auditory and visual modalities consisting of both primacy and recency effects. Experiment 2 found that retention of auditory and visual information was remarkably similar when assessed across a 10s interval. Experiments 3 and 4, taken together, showed that the recency effect in sensory memory is affected more by the type of response required (recognition vs. reproduction) than by the sensory modality employed. These studies suggest that auditory and visual sensory memory stores for nonverbal stimuli share similar properties with respect to serial-position effects and persistence over time.

  10. Safeguarding a Lunar Rover with Wald's Sequential Probability Ratio Test

    Science.gov (United States)

    Furlong, Michael; Dille, Michael; Wong, Uland; Nefian, Ara

    2016-01-01

    The virtual bumper is a safeguarding mechanism for autonomous and remotely operated robots. In this paper we take a new approach to the virtual bumper system by using an old statistical test. By using a modified version of Wald's sequential probability ratio test we demonstrate that we can reduce the number of false positive reported by the virtual bumper, thereby saving valuable mission time. We use the concept of sequential probability ratio to control vehicle speed in the presence of possible obstacles in order to increase certainty about whether or not obstacles are present. Our new algorithm reduces the chances of collision by approximately 98 relative to traditional virtual bumper safeguarding without speed control.

  11. Dual-time-point 18F-FDG PET imaging for diagnosis of disease type and disease activity in patients with idiopathic interstitial pneumonia

    International Nuclear Information System (INIS)

    Umeda, Yukihiro; Demura, Yoshiki; Ishizaki, Takeshi; Ameshima, Shingo; Miyamori, Isamu; Saito, Yuji; Tsuchida, Tatsuro; Fujibayashi, Yasuhisa; Okazawa, Hidehiko

    2009-01-01

    Individual clinical courses of idiopathic interstitial pneumonia (IIP) are variable and difficult to predict because the pathology and disease activity are contingent, and chest computed tomography (CT) provides little information about disease activity. In this study, we applied dual-time-point [ 18 F]-fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography (PET), commonly used for diagnosis of malignant tumours, to the differential diagnosis and prediction of disease progression in IIP patients. Fifty patients with IIP, including idiopathic pulmonary fibrosis (IPF, n = 21), non-specific interstitial pneumonia (NSIP, n = 18) and cryptogenic organizing pneumonia (COP, n = 11), underwent 18 F-FDG PET examinations at two time points: scan 1 at 60 min (early imaging) and scan 2 at 180 min (delayed imaging) after 18 F-FDG injection. The standardized uptake values (SUV) at the two points and the retention index (RI-SUV) calculated from them were evaluated and compared with chest CT findings, disease progression and disease types. To evaluate short-term disease progression, all patients were examined by pulmonary function test every 3 months for 1 year after 18 F-FDG PET scanning. The early SUV for COP (2.47 ± 0.74) was significantly higher than that for IPF (0.99 ± 0.29, p = 0.0002) or NSIP (1.22 ± 0.44, p= 0.0025). When an early SUV cut-off value of 1.5 and greater was used to distinguish COP from IPF and NSIP, the sensitivity, specificity and accuracy were 90.9, 94.3 and 93.5%, respectively. The RI-SUV for IPF and NSIP lesions was significantly greater in patients with deteriorated pulmonary function after 1 year of follow-up (progressive group, 13.0 ± 8.9%) than in cases without deterioration during the 1-year observation period (stable group, -16.8 ± 5.9%, p 18 F-FDG PET are useful parameters for the differential diagnosis and prediction of disease progression in patients with IIP. (orig.)

  12. The drug efficacy and adverse reactions in a mouse model of oral squamous cell carcinoma treated with oxaliplatin at different time points during a day

    Directory of Open Access Journals (Sweden)

    Yang K

    2013-06-01

    Full Text Available Kai Yang,1,2 Ningbo Zhao,1 Dan Zhao,1,2 Dan Chen,1 Yadong Li1 1Department of Oral and Maxillofacial Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 2Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Chongqing Medical University, Chongqing, People’s Republic of China Background: Recent studies have shown that the growth and proliferation of cancer cells in vivo exhibit circadian rhythm, and the efficacy and adverse reactions of platinum-based anticancer drugs administered at different times of the day vary significantly on colon cancer. However, since the circadian rhythms of growth and proliferation of various cancer cells often differ, the question of whether the administration of platinum anticancer drugs at different times of the day exerts significantly different efficacy and adverse effects on oral cancers remains to be elucidated. This study has compared the efficacy and adverse effects of oxaliplatin (L-OHP administration at different times during a day on oral squamous cell carcinoma in mice and has analyzed cellular circadian rhythms. Methods: The mouse model for oral squamous cell carcinoma was established in 75 nude mice, housed in a 12 hour light/12 hour dark cycle environment. The mice were randomly divided into five groups; four experimental groups were intravenously injected with L-OHP at four time points within a 24-hour period (4, 10, 16, and 22 hours after lights on [HALO]. The control group was intravenously injected with the same volume of saline. Treatment efficacy and adverse reactions were compared on the seventh day after the injection, at 22 HALO. The existence of circadian rhythms was determined by cosine analysis. Results: Only injections of L-OHP at 16 and 22 HALO significantly prolonged animal survival time. The adverse reactions in mice injected with L-OHP at 16 and 22 HALO were significantly less than those observed in mice administered L-OHP at 4 and 10 HALO

  13. Separation of left and right lungs using 3D information of sequential CT images and a guided dynamic programming algorithm

    Science.gov (United States)

    Park, Sang Cheol; Leader, Joseph Ken; Tan, Jun; Lee, Guee Sang; Kim, Soo Hyung; Na, In Seop; Zheng, Bin

    2011-01-01

    Objective this article presents a new computerized scheme that aims to accurately and robustly separate left and right lungs on CT examinations. Methods we developed and tested a method to separate the left and right lungs using sequential CT information and a guided dynamic programming algorithm using adaptively and automatically selected start point and end point with especially severe and multiple connections. Results the scheme successfully identified and separated all 827 connections on the total 4034 CT images in an independent testing dataset of CT examinations. The proposed scheme separated multiple connections regardless of their locations, and the guided dynamic programming algorithm reduced the computation time to approximately 4.6% in comparison with the traditional dynamic programming and avoided the permeation of the separation boundary into normal lung tissue. Conclusions The proposed method is able to robustly and accurately disconnect all connections between left and right lungs and the guided dynamic programming algorithm is able to remove redundant processing. PMID:21412104

  14. Cortical responses following simultaneous and sequential retinal neurostimulation with different return configurations.

    Science.gov (United States)

    Barriga-Rivera, Alejandro; Morley, John W; Lovell, Nigel H; Suaning, Gregg J

    2016-08-01

    Researchers continue to develop visual prostheses towards safer and more efficacious systems. However limitations still exist in the number of stimulating channels that can be integrated. Therefore there is a need for spatial and time multiplexing techniques to provide improved performance of the current technology. In particular, bright and high-contrast visual scenes may require simultaneous activation of several electrodes. In this research, a 24-electrode array was suprachoroidally implanted in three normally-sighted cats. Multi-unit activity was recorded from the primary visual cortex. Four stimulation strategies were contrasted to provide activation of seven electrodes arranged hexagonally: simultaneous monopolar, sequential monopolar, sequential bipolar and hexapolar. Both monopolar configurations showed similar cortical activation maps. Hexapolar and sequential bipolar configurations activated a lower number of cortical channels. Overall, the return configuration played a more relevant role in cortical activation than time multiplexing and thus, rapid sequential stimulation may assist in reducing the number of channels required to activate large retinal areas.

  15. Efficient sequential and parallel algorithms for record linkage.

    Science.gov (United States)

    Mamun, Abdullah-Al; Mi, Tian; Aseltine, Robert; Rajasekaran, Sanguthevar

    2014-01-01

    Integrating data from multiple sources is a crucial and challenging problem. Even though there exist numerous algorithms for record linkage or deduplication, they suffer from either large time needs or restrictions on the number of datasets that they can integrate. In this paper we report efficient sequential and parallel algorithms for record linkage which handle any number of datasets and outperform previous algorithms. Our algorithms employ hierarchical clustering algorithms as the basis. A key idea that we use is radix sorting on certain attributes to eliminate identical records before any further processing. Another novel idea is to form a graph that links similar records and find the connected components. Our sequential and parallel algorithms have been tested on a real dataset of 1,083,878 records and synthetic datasets ranging in size from 50,000 to 9,000,000 records. Our sequential algorithm runs at least two times faster, for any dataset, than the previous best-known algorithm, the two-phase algorithm using faster computation of the edit distance (TPA (FCED)). The speedups obtained by our parallel algorithm are almost linear. For example, we get a speedup of 7.5 with 8 cores (residing in a single node), 14.1 with 16 cores (residing in two nodes), and 26.4 with 32 cores (residing in four nodes). We have compared the performance of our sequential algorithm with TPA (FCED) and found that our algorithm outperforms the previous one. The accuracy is the same as that of this previous best-known algorithm.

  16. Results of simultaneous and sequential pediatric liver and kidney transplantation.

    Science.gov (United States)

    Rogers, J; Bueno, J; Shapiro, R; Scantlebury, V; Mazariegos, G; Fung, J; Reyes, J

    2001-11-27

    (86%) of seven sequentially transplanted kidneys developed acute cellular rejection compared with only two (25%) of eight simultaneously transplanted kidneys (P<0.04). Simultaneously transplanted kidneys were less likely to develop rejection than sequentially transplanted kidneys in this series. This did not have any bearing on patient or graft survival rates. Mortality correlated directly with the severity of United Network of Organ Sharing status at the time of kidney transplantation. Candidates for simultaneous or sequential LTx/KTx should be prioritized based on medical stability to optimize distribution of scarce renal allografts.

  17. Real-time estimation of prostate tumor rotation and translation with a kV imaging system based on an iterative closest point algorithm

    International Nuclear Information System (INIS)

    Tehrani, Joubin Nasehi; O’Brien, Ricky T; Keall, Paul; Poulsen, Per Rugaard

    2013-01-01

    Previous studies have shown that during cancer radiotherapy a small translation or rotation of the tumor can lead to errors in dose delivery. Current best practice in radiotherapy accounts for tumor translations, but is unable to address rotation due to a lack of a reliable real-time estimate. We have developed a method based on the iterative closest point (ICP) algorithm that can compute rotation from kilovoltage x-ray images acquired during radiation treatment delivery. A total of 11 748 kilovoltage (kV) images acquired from ten patients (one fraction for each patient) were used to evaluate our tumor rotation algorithm. For each kV image, the three dimensional coordinates of three fiducial markers inside the prostate were calculated. The three dimensional coordinates were used as input to the ICP algorithm to calculate the real-time tumor rotation and translation around three axes. The results show that the root mean square error was improved for real-time calculation of tumor displacement from a mean of 0.97 mm with the stand alone translation to a mean of 0.16 mm by adding real-time rotation and translation displacement with the ICP algorithm. The standard deviation (SD) of rotation for the ten patients was 2.3°, 0.89° and 0.72° for rotation around the right–left (RL), anterior–posterior (AP) and superior–inferior (SI) directions respectively. The correlation between all six degrees of freedom showed that the highest correlation belonged to the AP and SI translation with a correlation of 0.67. The second highest correlation in our study was between the rotation around RL and rotation around AP, with a correlation of −0.33. Our real-time algorithm for calculation of rotation also confirms previous studies that have shown the maximum SD belongs to AP translation and rotation around RL. ICP is a reliable and fast algorithm for estimating real-time tumor rotation which could create a pathway to investigational clinical treatment studies requiring

  18. Dew Point

    OpenAIRE

    Goldsmith, Shelly

    1999-01-01

    Dew Point was a solo exhibition originating at PriceWaterhouseCoopers Headquarters Gallery, London, UK and toured to the Centre de Documentacio i Museu Textil, Terrassa, Spain and Gallery Aoyama, Tokyo, Japan.

  19. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ...

  20. Tipping Point

    Science.gov (United States)

    ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ...

  1. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head ... see news reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The ...

  2. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head ... TV falls with about the same force as child falling from the third story of a building. ...

  3. Tipping Point

    Medline Plus

    Full Text Available ... Tipping Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture ... about horrible accidents involving young children and furniture, appliance and tv tip-overs. The force of a ...

  4. The effect of lineup member similarity on recognition accuracy in simultaneous and sequential lineups

    OpenAIRE

    Flowe, Heather D.

    2005-01-01

    Prior research suggests that simultaneous lineup procedures, which involve presenting at once all of the alternatives, encourage witnesses to identify the relatively most familiar face. In contrast, when lineup alternatives are evaluated one at a time, or sequentially, identifying a face is not influenced by previously seen faces in the lineup. Instead, a face will be chosen from a sequential lineup only when it is a sufficient match to the perpetrator in memory. The present study investigate...

  5. Simple and flexible SAS and SPSS programs for analyzing lag-sequential categorical data.

    Science.gov (United States)

    O'Connor, B P

    1999-11-01

    This paper describes simple and flexible programs for analyzing lag-sequential categorical data, using SAS and SPSS. The programs read a stream of codes and produce a variety of lag-sequential statistics, including transitional frequencies, expected transitional frequencies, transitional probabilities, adjusted residuals, z values, Yule's Q values, likelihood ratio tests of stationarity across time and homogeneity across groups or segments, transformed kappas for unidirectional dependence, bidirectional dependence, parallel and nonparallel dominance, and significance levels based on both parametric and randomization tests.

  6. Competitive interactions affect working memory performance for both simultaneous and sequential stimulus presentation

    OpenAIRE

    Ahmad, J; Swan, G; Bowman, H; Wyble, B; De Ozorio Nobre, AC; Shapiro, KL; McNab, F

    2017-01-01

    Competition between simultaneously presented visual stimuli lengthens reaction time and reduces both the BOLD response and neural firing. In contrast, conditions of sequential presentation have been assumed to be free from competition. Here we manipulated the spatial proximity of stimuli (Near versus Far conditions) to examine the effects of simultaneous and sequential competition on different measures of working memory (WM) for colour. With simultaneous presentation, the measure of WM precis...

  7. A Seamless Handoff Scheme with Access Point Load Balance for Real-Time Services Support in 802.11 Wireless LANs

    Science.gov (United States)

    Manodham, Thavisak; Loyola, Luis; Miki, Tetsuya

    IEEE 802.11 wirelesses LANs (WLANs) have been rapidly deployed in enterprises, public areas, and households. Voice-over-IP (VoIP) and similar applications are now commonly used in mobile devices over wireless networks. Recent works have improved the quality of service (QoS) offering higher data rates to support various kinds of real-time applications. However, besides the need for higher data rates, seamless handoff and load balancing among APs are key issues that must be addressed in order to continue supporting real-time services across wireless LANs and providing fair services to all users. In this paper, we introduce a novel access point (AP) with two transceivers that improves network efficiency by supporting seamless handoff and traffic load balancing in a wireless network. In our proposed scheme, the novel AP uses the second transceiver to scan and find neighboring STAs in the transmission range and then sends the results to neighboring APs, which compare and analyze whether or not the STA should perform a handoff. The initial results from our simulations show that the novel AP module is more effective than the conventional scheme and a related work in terms of providing a handoff process with low latency and sharing traffic load with neighbor APs.

  8. Parity-Time Symmetry and the Toy Models of Gain-Loss Dynamics near the Real Kato’s Exceptional Points

    Directory of Open Access Journals (Sweden)

    Miloslav Znojil

    2016-06-01

    Full Text Available For a given operator D ( t of an observable in theoretical parity-time symmetric quantum physics (or for its evolution-generator analogues in the experimental gain-loss classical optics, etc. the instant t c r i t i c a l of a spontaneous breakdown of the parity-time alias gain-loss symmetry should be given, in the rigorous language of mathematics, the Kato’s name of an “exceptional point”, t c r i t i c a l = t ( E P . In the majority of conventional applications the exceptional point (EP values are not real. In our paper, we pay attention to several exactly tractable toy-model evolutions for which at least some of the values of t ( E P become real. These values are interpreted as “instants of a catastrophe”, be it classical or quantum. In the classical optical setting the discrete nature of our toy models might make them amenable to simulations. In the latter context the instant of Big Bang is mentioned as an illustrative sample of possible physical meaning of such an EP catastrophe in quantum cosmology.

  9. Model-based testing for space-time interaction using point processes: An application to psychiatric hospital admissions in an urban area.

    Science.gov (United States)

    Meyer, Sebastian; Warnke, Ingeborg; Rössler, Wulf; Held, Leonhard

    2016-05-01

    Spatio-temporal interaction is inherent to cases of infectious diseases and occurrences of earthquakes, whereas the spread of other events, such as cancer or crime, is less evident. Statistical significance tests of space-time clustering usually assess the correlation between the spatial and temporal (transformed) distances of the events. Although appealing through simplicity, these classical tests do not adjust for the underlying population nor can they account for a distance decay of interaction. We propose to use the framework of an endemic-epidemic point process model to jointly estimate a background event rate explained by seasonal and areal characteristics, as well as a superposed epidemic component representing the hypothesis of interest. We illustrate this new model-based test for space-time interaction by analysing psychiatric inpatient admissions in Zurich, Switzerland (2007-2012). Several socio-economic factors were found to be associated with the admission rate, but there was no evidence of general clustering of the cases. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Clinical evaluation of whole-body oncologic PET with time-of-flight and point-spread function for the hybrid PET/MR system.

    Science.gov (United States)

    Shang, Kun; Cui, Bixiao; Ma, Jie; Shuai, Dongmei; Liang, Zhigang; Jansen, Floris; Zhou, Yun; Lu, Jie; Zhao, Guoguang

    2017-08-01

    Hybrid positron emission tomography/magnetic resonance (PET/MR) imaging is a new multimodality imaging technology that can provide structural and functional information simultaneously. The aim of this study was to investigate the effects of the time-of-flight (TOF) and point-spread function (PSF) on small lesions observed in PET/MR images from clinical patient image sets. This study evaluated 54 small lesions in 14 patients who had undergone 18 F-fluorodeoxyglucose (FDG) PET/MR. Lesions up to 30mm in diameter were included. The PET data were reconstructed with a baseline ordered-subsets expectation-maximization (OSEM) algorithm, OSEM+PSF, OSEM+TOF and OSEM+TOF+PSF. PET image quality and small lesions were visually evaluated and scored by a 3-point scale. A quantitative analysis was then performed using the mean and maximum standardized uptake value (SUV) of the small lesions (SUV mean and SUV max ). The lesions were divided into two groups according to the long-axis diameter and the location respectively and evaluated with each reconstruction algorithm. We also evaluated the background signal by analyzing the SUV liver . OSEM+TOF+PSF provided the highest value and OSEM+TOF or PSF showed a higher value than OSEM for the visual assessment and quantitative analysis. The combination of TOF and PSF increased the SUV mean by 26.6% and the SUV max by 30.0%. The SUV liver was not influenced by PSF or TOF. For the OSEM+TOF+PSF model, the change in SUV mean and SUV max for lesions PET/MR images, potentially improving small lesion detectability. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Endogenous sequential cortical activity evoked by visual stimuli.

    Science.gov (United States)

    Carrillo-Reid, Luis; Miller, Jae-Eun Kang; Hamm, Jordan P; Jackson, Jesse; Yuste, Rafael

    2015-06-10

    Although the functional properties of individual neurons in primary visual cortex have been studied intensely, little is known about how neuronal groups could encode changing visual stimuli using temporal activity patterns. To explore this, we used in vivo two-photon calcium imaging to record the activity of neuronal populations in primary visual cortex of awake mice in the presence and absence of visual stimulation. Multidimensional analysis of the network activity allowed us to identify neuronal ensembles defined as groups of cells firing in synchrony. These synchronous groups of neurons were themselves activated in sequential temporal patterns, which repeated at much higher proportions than chance and were triggered by specific visual stimuli such as natural visual scenes. Interestingly, sequential patterns were also present in recordings of spontaneous activity without any sensory stimulation and were accompanied by precise firing sequences at the single-cell level. Moreover, intrinsic dynamics could be used to predict the occurrence of future neuronal ensembles. Our data demonstrate that visual stimuli recruit similar sequential patterns to the ones observed spontaneously, consistent with the hypothesis that already existing Hebbian cell assemblies firing in predefined temporal sequences could be the microcircuit substrate that encodes visual percepts changing in time. Copyright © 2015 Carrillo-Reid et al.

  12. Accurately controlled sequential self-folding structures by polystyrene film

    Science.gov (United States)

    Deng, Dongping; Yang, Yang; Chen, Yong; Lan, Xing; Tice, Jesse

    2017-08-01

    Four-dimensional (4D) printing overcomes the traditional fabrication limitations by designing heterogeneous materials to enable the printed structures evolve over time (the fourth dimension) under external stimuli. Here, we present a simple 4D printing of self-folding structures that can be sequentially and accurately folded. When heated above their glass transition temperature pre-strained polystyrene films shrink along the XY plane. In our process silver ink traces printed on the film are used to provide heat stimuli by conducting current to trigger the self-folding behavior. The parameters affecting the folding process are studied and discussed. Sequential folding and accurately controlled folding angles are achieved by using printed ink traces and angle lock design. Theoretical analyses are done to guide the design of the folding processes. Programmable structures such as a lock and a three-dimensional antenna are achieved to test the feasibility and potential applications of this method. These self-folding structures change their shapes after fabrication under controlled stimuli (electric current) and have potential applications in the fields of electronics, consumer devices, and robotics. Our design and fabrication method provides an easy way by using silver ink printed on polystyrene films to 4D print self-folding structures for electrically induced sequential folding with angular control.

  13. Immediately sequential bilateral cataract surgery: advantages and disadvantages.

    Science.gov (United States)

    Singh, Ranjodh; Dohlman, Thomas H; Sun, Grace

    2017-01-01

    The number of cataract surgeries performed globally will continue to rise to meet the needs of an aging population. This increased demand will require healthcare systems and providers to find new surgical efficiencies while maintaining excellent surgical outcomes. Immediately sequential bilateral cataract surgery (ISBCS) has been proposed as a solution and is increasingly being performed worldwide. The purpose of this review is to discuss the advantages and disadvantages of ISBCS. When appropriate patient selection occurs and guidelines are followed, ISBCS is comparable with delayed sequential bilateral cataract surgery in long-term patient satisfaction, visual acuity and complication rates. In addition, the risk of bilateral postoperative endophthalmitis and concerns of poorer refractive outcomes have not been supported by the literature. ISBCS is cost-effective for the patient, healthcare payors and society, but current reimbursement models in many countries create significant financial barriers for facilities and surgeons. As demand for cataract surgery rises worldwide, ISBCS will become increasingly important as an alternative to delayed sequential bilateral cataract surgery. Advantages include potentially decreased wait times for surgery, patient convenience and cost savings for healthcare payors. Although they are comparable in visual acuity and complication rates, hurdles that prevent wide adoption include liability concerns as ISBCS is not an established standard of care, economic constraints for facilities and surgeons and inability to fine-tune intraocular lens selection in the second eye. Given these considerations, an open discussion regarding the advantages and disadvantages of ISBCS is important for appropriate patient selection.

  14. A node linkage approach for sequential pattern mining.

    Directory of Open Access Journals (Sweden)

    Osvaldo Navarro

    Full Text Available Sequential Pattern Mining is a widely addressed problem in data mining, with applications such as analyzing Web usage, examining purchase behavior, and text mining, among others. Nevertheless, with the dramatic increase in data volume, the current approaches prove inefficient when dealing with large input datasets, a large number of different symbols and low minimum supports. In this paper, we propose a new sequential pattern mining algorithm, which follows a pattern-growth scheme to discover sequential patterns. Unlike most pattern growth algorithms, our approach does not build a data structure to represent the input dataset, but instead accesses the required sequences through pseudo-projection databases, achieving better runtime and reducing memory requirements. Our algorithm traverses the search space in a depth-first fashion and only preserves in memory a pattern node linkage and the pseudo-projections required for the branch being explored at the time. Experimental results show that our new approach, the Node Linkage Depth-First Traversal algorithm (NLDFT, has better performance and scalability in comparison with state of the art algorithms.

  15. Optimisation of beryllium-7 gamma analysis following BCR sequential extraction

    International Nuclear Information System (INIS)

    Taylor, A.; Blake, W.H.; Keith-Roach, M.J.

    2012-01-01

    Graphical abstract: Showing decrease in analytical uncertainty using the optimal (combined preconcentrated sample extract) method. nv (no value) where extract activities were 7 Be geochemical behaviour is required to support tracer studies. ► Sequential extraction with natural 7 Be returns high analytical uncertainties. ► Preconcentrating extracts from a large sample mass improved analytical uncertainty. ► This optimised method can be readily employed in studies using low activity samples. - Abstract: The application of cosmogenic 7 Be as a sediment tracer at the catchment-scale requires an understanding of its geochemical associations in soil to underpin the assumption of irreversible adsorption. Sequential extractions offer a readily accessible means of determining the associations of 7 Be with operationally defined soil phases. However, the subdivision of the low activity concentrations of fallout 7 Be in soils into geochemical fractions can introduce high gamma counting uncertainties. Extending analysis time significantly is not always an option for batches of samples, owing to the on-going decay of 7 Be (t 1/2 = 53.3 days). Here, three different methods of preparing and quantifying 7 Be extracted using the optimised BCR three-step scheme have been evaluated and compared with a focus on reducing analytical uncertainties. The optimal method involved carrying out the BCR extraction in triplicate, sub-sampling each set of triplicates for stable Be analysis before combining each set and coprecipitating the 7 Be with metal oxyhydroxides to produce a thin source for gamma analysis. This method was applied to BCR extractions of natural 7 Be in four agricultural soils. The approach gave good counting statistics from a 24 h analysis period (∼10% (2σ) where extract activity >40% of total activity) and generated statistically useful sequential extraction profiles. Total recoveries of 7 Be fell between 84 and 112%. The stable Be data demonstrated that the

  16. Synthetic Aperture Sequential Beamforming implemented on multi-core platforms

    DEFF Research Database (Denmark)

    Kjeldsen, Thomas; Lassen, Lee; Hemmsen, Martin Christian

    2014-01-01

    This paper compares several computational ap- proaches to Synthetic Aperture Sequential Beamforming (SASB) targeting consumer level parallel processors such as multi-core CPUs and GPUs. The proposed implementations demonstrate that ultrasound imaging using SASB can be executed in real- time with ...... per second) on an Intel Core i7 2600 CPU with an AMD HD7850 and a NVIDIA GTX680 GPU. The fastest CPU and GPU implementations use 14% and 1.3% of the real-time budget of 62 ms/frame, respectively. The maximum achieved processing rate is 1265 frames/s....

  17. Which is the ideal point of time to perform intraoperative 3D imaging in dorsal stabilisation of thoracolumbar spine fractures? A matched pair analysis.

    Science.gov (United States)

    Beck, M; Mittlmeier, T; Gierer, P; Rotter, R; Harms, C; Gradl, G

    2010-10-01

    After dorsal stabilisation of vertebral fractures by an internal fixateur the postoperative computed tomography is a standard procedure to control the positions of the pedicle screws, the success of the reposition, the clearance of the spinal canal and to plane an additive secondary ventral stabilisation. An intraoperative scan with a 3D image intensifier may clarify these questions directly after the implantation with the possibility of an immediate correction of the implants. The aim of this study was to find out the optimal point of time to perform an intraoperative 3D scan and if a postoperative computed tomography is dispensable. Intraoperative 3D scans were carried out on 33 patients with thoracolumbar spine fractures (T11-L5) after bi-segmental fixateur interne montage (Group 1). A matched pair group of 33 patients (Group 2) with a 3D scan after implantation of pedicle screws was built. A postoperative computed tomography of the instrumented spinal section was done in all patients. The following measurements were done in sagittal and axial reconstruction planes and were compared: classification of screw positions, maximal axial diameter of pedicles, cortical perforation of the screws. Additionally in Group 1 the distance between the upper and lower end plates of the injured section, the height of posterior vertebral body wall, the dislocation of the posterior wall and the minimal diameter of the spinal canal were measured. The intraoperative scoring of pedicle screws positions and the measurement of pedicle width showed in both groups a significant accordance with the computed tomography determinations. The measurements "posterior wall dislocation" and "diameter of spinal canal" were only possible in 24 3D scans and showed a significant difference compared with the CT data. The picture quality in Group 2 was scored significantly better than for Group 1 with the complete assembly of the fixateur. The ideal point of time for an intraoperative 3D imaging with

  18. Dihydroazulene photoswitch operating in sequential tunneling regime

    DEFF Research Database (Denmark)

    Broman, Søren Lindbæk; Lara-Avila, Samuel; Thisted, Christine Lindbjerg

    2012-01-01

    to electrodes so that the electron transport goes by sequential tunneling. To assure weak coupling, the DHA switching kernel is modified by incorporating p-MeSC6H4 end-groups. Molecules are prepared by Suzuki cross-couplings on suitable halogenated derivatives of DHA. The synthesis presents an expansion of our......, incorporating a p-MeSC6H4 anchoring group in one end, has been placed in a silver nanogap. Conductance measurements justify that transport through both DHA (high resistivity) and VHF (low resistivity) forms goes by sequential tunneling. The switching is fairly reversible and reenterable; after more than 20 ON...

  19. Sequential unconstrained minimization algorithms for constrained optimization

    International Nuclear Information System (INIS)

    Byrne, Charles

    2008-01-01

    The problem of minimizing a function f(x):R J → R, subject to constraints on the vector variable x, occurs frequently in inverse problems. Even without constraints, finding a minimizer of f(x) may require iterative methods. We consider here a general class of iterative algorithms that find a solution to the constrained minimization problem as the limit of a sequence of vectors, each solving an unconstrained minimization problem. Our sequential unconstrained minimization algorithm (SUMMA) is an iterative procedure for constrained minimization. At the kth step we minimize the function G k (x)=f(x)+g k (x), to obtain x k . The auxiliary functions g k (x):D subset of R J → R + are nonnegative on the set D, each x k is assumed to lie within D, and the objective is to minimize the continuous function f:R J → R over x in the set C = D-bar, the closure of D. We assume that such minimizers exist, and denote one such by x-circumflex. We assume that the functions g k (x) satisfy the inequalities 0≤g k (x)≤G k-1 (x)-G k-1 (x k-1 ), for k = 2, 3, .... Using this assumption, we show that the sequence {(x k )} is decreasing and converges to f(x-circumflex). If the restriction of f(x) to D has bounded level sets, which happens if x-circumflex is unique and f(x) is closed, proper and convex, then the sequence {x k } is bounded, and f(x*)=f(x-circumflex), for any cluster point x*. Therefore, if x-circumflex is unique, x* = x-circumflex and {x k } → x-circumflex. When x-circumflex is not unique, convergence can still be obtained, in particular cases. The SUMMA includes, as particular cases, the well-known barrier- and penalty-function methods, the simultaneous multiplicative algebraic reconstruction technique (SMART), the proximal minimization algorithm of Censor and Zenios, the entropic proximal methods of Teboulle, as well as certain cases of gradient descent and the Newton–Raphson method. The proof techniques used for SUMMA can be extended to obtain related results

  20. Comparative evaluation of SUV, tumor-to-blood standard uptake ratio (SUR), and dual time point measurements for assessment of the metabolic uptake rate in FDG PET.

    Science.gov (United States)

    Hofheinz, Frank; Hoff, Jörg van den; Steffen, Ingo G; Lougovski, Alexandr; Ego, Kilian; Amthauer, Holger; Apostolova, Ivayla

    2016-12-01

    We have demonstrated recently that the tumor-to-blood standard uptake ratio (SUR) is superior to tumor standardized uptake value (SUV) as a surrogate of the metabolic uptake rate K m of fluorodeoxyglucose (FDG), overcoming several of the known shortcomings of the SUV approach: excellent linear correlation of SUR and K m from Patlak analysis was found using dynamic imaging of liver metastases. However, due to the perfectly standardized uptake period used for SUR determination and the comparatively short uptake period, these results are not automatically valid and applicable for clinical whole-body examinations in which the uptake periods (T) are distinctly longer and can vary considerably. Therefore, the aim of this work was to investigate the correlation between SUR derived from clinical static whole-body scans and K m-surrogate derived from dual time point (DTP) measurements. DTP (18)F-FDG PET/CT was performed in 90 consecutive patients with histologically proven non-small cell lung cancer (NSCLC). In the PET images, the primary tumor was delineated with an adaptive threshold method. For determination of the blood SUV, an aorta region of interest (ROI) was delineated manually in the attenuation CT and transferred to the PET image. Blood SUV was computed as the mean value of the aorta ROI. SUR values were computed as ratio of tumor SUV and blood SUV. SUR values from the early time point of each DTP measurement were scan time corrected to 75 min postinjection (SURtc). As surrogate of K m, we used the SUR(T) slope, K slope, derived from DTP measurements since it is proportional to the latter under the given circumstances. The correlation of SUV and SURtc with K slope was investigated. The prognostic value of SUV, SURtc, and K slope for overall survival (OS) and progression-free survival (PFS) was investigated with univariate Cox regression in a homogeneous subgroup (N=31) treated with primary chemoradiation. Correlation analysis revealed for both, SUV and SURtc, a