WorldWideScience

Sample records for sequential serum samples

  1. MaxEnt queries and sequential sampling

    International Nuclear Information System (INIS)

    Riegler, Peter; Caticha, Nestor

    2001-01-01

    In this paper we pose the question: After gathering N data points, at what value of the control parameter should the next measurement be done? We propose an on-line algorithm which samples optimally by maximizing the gain in information on the parameters to be measured. We show analytically that the information gain is maximum for those potential measurements whose outcome is most unpredictable, i.e. for which the predictive distribution has maximum entropy. The resulting algorithm is applied to exponential analysis

  2. Sequential determination of important ecotoxic radionuclides in nuclear waste samples

    International Nuclear Information System (INIS)

    Bilohuscin, J.

    2016-01-01

    In the dissertation thesis we focused on the development and optimization of a sequential determination method for radionuclides 93 Zr, 94 Nb, 99 Tc and 126 Sn, employing extraction chromatography sorbents TEVA (R) Resin and Anion Exchange Resin, supplied by Eichrom Industries. Prior to the attestation of sequential separation of these proposed radionuclides from radioactive waste samples, a unique sequential procedure of 90 Sr, 239 Pu, 241 Am separation from urine matrices was tried, using molecular recognition sorbents of AnaLig (R) series and extraction chromatography sorbent DGA (R) Resin. On these experiments, four various sorbents were continually used for separation, including PreFilter Resin sorbent, which removes interfering organic materials present in raw urine. After the acquisition of positive results of this sequential procedure followed experiments with a 126 Sn separation using TEVA (R) Resin and Anion Exchange Resin sorbents. Radiochemical recoveries obtained from samples of radioactive evaporate concentrates and sludge showed high efficiency of the separation, while values of 126 Sn were under the minimum detectable activities MDA. Activity of 126 Sn was determined after ingrowth of daughter nuclide 126m Sb on HPGe gamma detector, with minimal contamination of gamma interfering radionuclides with decontamination factors (D f ) higher then 1400 for 60 Co and 47000 for 137 Cs. Based on the acquired experiments and results of these separation procedures, a complex method of sequential separation of 93 Zr, 94 Nb, 99 Tc and 126 Sn was proposed, which included optimization steps similar to those used in previous parts of the dissertation work. Application of the sequential separation method for sorbents TEVA (R) Resin and Anion Exchange Resin on real samples of radioactive wastes provided satisfactory results and an economical, time sparing, efficient method. (author)

  3. Sequential sampling: a novel method in farm animal welfare assessment.

    Science.gov (United States)

    Heath, C A E; Main, D C J; Mullan, S; Haskell, M J; Browne, W J

    2016-02-01

    Lameness in dairy cows is an important welfare issue. As part of a welfare assessment, herd level lameness prevalence can be estimated from scoring a sample of animals, where higher levels of accuracy are associated with larger sample sizes. As the financial cost is related to the number of cows sampled, smaller samples are preferred. Sequential sampling schemes have been used for informing decision making in clinical trials. Sequential sampling involves taking samples in stages, where sampling can stop early depending on the estimated lameness prevalence. When welfare assessment is used for a pass/fail decision, a similar approach could be applied to reduce the overall sample size. The sampling schemes proposed here apply the principles of sequential sampling within a diagnostic testing framework. This study develops three sequential sampling schemes of increasing complexity to classify 80 fully assessed UK dairy farms, each with known lameness prevalence. Using the Welfare Quality herd-size-based sampling scheme, the first 'basic' scheme involves two sampling events. At the first sampling event half the Welfare Quality sample size is drawn, and then depending on the outcome, sampling either stops or is continued and the same number of animals is sampled again. In the second 'cautious' scheme, an adaptation is made to ensure that correctly classifying a farm as 'bad' is done with greater certainty. The third scheme is the only scheme to go beyond lameness as a binary measure and investigates the potential for increasing accuracy by incorporating the number of severely lame cows into the decision. The three schemes are evaluated with respect to accuracy and average sample size by running 100 000 simulations for each scheme, and a comparison is made with the fixed size Welfare Quality herd-size-based sampling scheme. All three schemes performed almost as well as the fixed size scheme but with much smaller average sample sizes. For the third scheme, an overall

  4. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    fasting 10 mL of blood sample from each individual was taken and was allowed to clot in plastic tube for 2 h at room temperature. The serum was collected by centrifugation. The samples were stored under liquid nitrogen for NMR analysis. Before NMR analysis, 600 µL of the samples were taken in a 5 mm high quality NMR ...

  5. POLYP: an automatic device for drawing sequential samples of gas

    Energy Technology Data Exchange (ETDEWEB)

    Gaglione, P; Koechler, C; Stanchi, L

    1974-12-01

    Polyp is an automatic device consisting of electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. The other seven pumps will inflate sequentially the other bags. The instrument is powered by rechargeable batteries and realized with C-MUS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof.

  6. POLYP: an automatic device for drawing sequential samples of gas

    International Nuclear Information System (INIS)

    Gaglione, P.; Koechler, C.; Stanchi, L.

    1974-12-01

    POLYP is an automatic device consisting of an electronic equipment which drives sequentially 8 small pumps for drawing samples of gas. The electronic circuit is driven by a quartz oscillator and allows for the preselection of a waiting time in such a manner that a set of similar instruments placed in suitable position in the open country will start simultaneously. At the same time the first pump of each instrument will inflate a plastic bag for a preset time. Thereafter the other seven pumps will inflate sequentially the other bag. The instrument is powered by rechargeable batteries and realized with C-MOS integrated circuits for a nearly negligible consumption. As it is foreseen for field operation it is waterproof

  7. The subtyping of primary aldosteronism by adrenal vein sampling: sequential blood sampling causes factitious lateralization.

    Science.gov (United States)

    Rossitto, Giacomo; Battistel, Michele; Barbiero, Giulio; Bisogni, Valeria; Maiolino, Giuseppe; Diego, Miotto; Seccia, Teresa M; Rossi, Gian Paolo

    2018-02-01

    The pulsatile secretion of adrenocortical hormones and a stress reaction occurring when starting adrenal vein sampling (AVS) can affect the selectivity and also the assessment of lateralization when sequential blood sampling is used. We therefore tested the hypothesis that a simulated sequential blood sampling could decrease the diagnostic accuracy of lateralization index for identification of aldosterone-producing adenoma (APA), as compared with bilaterally simultaneous AVS. In 138 consecutive patients who underwent subtyping of primary aldosteronism, we compared the results obtained simultaneously bilaterally when starting AVS (t-15) and 15 min after (t0), with those gained with a simulated sequential right-to-left AVS technique (R ⇒ L) created by combining hormonal values obtained at t-15 and at t0. The concordance between simultaneously obtained values at t-15 and t0, and between simultaneously obtained values and values gained with a sequential R ⇒ L technique, was also assessed. We found a marked interindividual variability of lateralization index values in the patients with bilaterally selective AVS at both time point. However, overall the lateralization index simultaneously determined at t0 provided a more accurate identification of APA than the simulated sequential lateralization indexR ⇒ L (P = 0.001). Moreover, regardless of which side was sampled first, the sequential AVS technique induced a sequence-dependent overestimation of lateralization index. While in APA patients the concordance between simultaneous AVS at t0 and t-15 and between simultaneous t0 and sequential technique was moderate-to-good (K = 0.55 and 0.66, respectively), in non-APA patients, it was poor (K = 0.12 and 0.13, respectively). Sequential AVS generates factitious between-sides gradients, which lower its diagnostic accuracy, likely because of the stress reaction arising upon starting AVS.

  8. Sequential sampling of visual objects during sustained attention.

    Directory of Open Access Journals (Sweden)

    Jianrong Jia

    2017-06-01

    Full Text Available In a crowded visual scene, attention must be distributed efficiently and flexibly over time and space to accommodate different contexts. It is well established that selective attention enhances the corresponding neural responses, presumably implying that attention would persistently dwell on the task-relevant item. Meanwhile, recent studies, mostly in divided attentional contexts, suggest that attention does not remain stationary but samples objects alternately over time, suggesting a rhythmic view of attention. However, it remains unknown whether the dynamic mechanism essentially mediates attentional processes at a general level. Importantly, there is also a complete lack of direct neural evidence reflecting whether and how the brain rhythmically samples multiple visual objects during stimulus processing. To address these issues, in this study, we employed electroencephalography (EEG and a temporal response function (TRF approach, which can dissociate responses that exclusively represent a single object from the overall neuronal activity, to examine the spatiotemporal characteristics of attention in various attentional contexts. First, attention, which is characterized by inhibitory alpha-band (approximately 10 Hz activity in TRFs, switches between attended and unattended objects every approximately 200 ms, suggesting a sequential sampling even when attention is required to mostly stay on the attended object. Second, the attentional spatiotemporal pattern is modulated by the task context, such that alpha-mediated switching becomes increasingly prominent as the task requires a more uniform distribution of attention. Finally, the switching pattern correlates with attentional behavioral performance. Our work provides direct neural evidence supporting a generally central role of temporal organization mechanism in attention, such that multiple objects are sequentially sorted according to their priority in attentional contexts. The results suggest

  9. Adrenal vein sampling in primary aldosteronism: concordance of simultaneous vs sequential sampling.

    Science.gov (United States)

    Almarzooqi, Mohamed-Karji; Chagnon, Miguel; Soulez, Gilles; Giroux, Marie-France; Gilbert, Patrick; Oliva, Vincent L; Perreault, Pierre; Bouchard, Louis; Bourdeau, Isabelle; Lacroix, André; Therasse, Eric

    2017-02-01

    Many investigators believe that basal adrenal venous sampling (AVS) should be done simultaneously, whereas others opt for sequential AVS for simplicity and reduced cost. This study aimed to evaluate the concordance of sequential and simultaneous AVS methods. Between 1989 and 2015, bilateral simultaneous sets of basal AVS were obtained twice within 5 min, in 188 consecutive patients (59 women and 129 men; mean age: 53.4 years). Selectivity was defined by adrenal-to-peripheral cortisol ratio ≥2, and lateralization was defined as an adrenal aldosterone-to-cortisol ratio ≥2, the contralateral side. Sequential AVS was simulated using right sampling at -5 min (t = -5) and left sampling at 0 min (t = 0). There was no significant difference in mean selectivity ratio (P = 0.12 and P = 0.42 for the right and left sides respectively) and in mean lateralization ratio (P = 0.93) between t = -5 and t = 0. Kappa for selectivity between 2 simultaneous AVS was 0.71 (95% CI: 0.60-0.82), whereas it was 0.84 (95% CI: 0.76-0.92) and 0.85 (95% CI: 0.77-0.93) between sequential and simultaneous AVS at respectively -5 min and at 0 min. Kappa for lateralization between 2 simultaneous AVS was 0.84 (95% CI: 0.75-0.93), whereas it was 0.86 (95% CI: 0.78-0.94) and 0.80 (95% CI: 0.71-0.90) between sequential AVS and simultaneous AVS at respectively -5 min at 0 min. Concordance between simultaneous and sequential AVS was not different than that between 2 repeated simultaneous AVS in the same patient. Therefore, a better diagnostic performance is not a good argument to select the AVS method. © 2017 European Society of Endocrinology.

  10. Proteome profiling analysis of human ovarian cancer serum samples

    International Nuclear Information System (INIS)

    Cognetti, F.; Citro, G.

    2009-01-01

    Mass Spectrometry represents a powerful tool in cancer research to discovery of potential bio markers through peak identification from serum profiling. By using high resolution MALDITOF and bioinformatic analysis almost 400 serum sample homogeneously distributed between biopsy confirmed ovarian cancer and high risk serum samples were analyzed. Each serum sample run in duplicate and whole serum sample preparation procedure has been performed by Hamilton Star Robot in order to reduce bias and the replicates with a low Pearson coefficient are removed. After automated reverse phase magnetic beads separation the samples were tested in MALDI-TOF

  11. Fractionation of plutonium in environmental and bio-shielding concrete samples using dynamic sequential extraction

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin

    2010-01-01

    Fractionation of plutonium isotopes (238Pu, 239,240Pu) in environmental samples (i.e. soil and sediment) and bio-shielding concrete from decommissioning of nuclear reactor were carried out by dynamic sequential extraction using an on-line sequential injection (SI) system combined with a specially...

  12. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    Metabonomics offers a distinct advantage over other tests as it can be ... Metabolic profiling in heart disease has also been successfully ... resonances of the small metabolites showing fingerprints of serum metabolomic profile (Figure. 3).

  13. Metabolite characterization in serum samples from normal healthy ...

    African Journals Online (AJOL)

    Metabolite characterization in serum samples from normal healthy human subjects by 1H and 13C NMR spectroscopy. D Misra, U Bajpai. Abstract. One and two dimensional NMR spectroscopy has been employed to characterize the various metabolites of serum control healthy samples. Two dimensional heteronuclear ...

  14. Sequential effects in pigeon delayed matching-to-sample performance.

    Science.gov (United States)

    Roitblat, H L; Scopatz, R A

    1983-04-01

    Pigeons were tested in a three-alternative delayed matching-to-sample task in which second-choices were permitted following first-choice errors. Sequences of responses both within and between trials were examined in three experiments. The first experiment demonstrates that the sample information contained in first-choice errors is not sufficient to account for the observed pattern of second choices. This result implies that second-choices following first-choice errors are based on a second examination of the contents of working memory. Proactive interference was found in the second experiment in the form of a dependency, beyond that expected on the basis of trial independent response bias, of first-choices from one trial on the first-choice emitted on the previous trial. Samples from the previous trial were not found to exert a significant influence on later trials. The magnitude of the intertrial association (Experiment 3) did not depend on the duration of the intertrial interval. In contrast, longer intertrial intervals and longer sample durations did facilitate choice accuracy, by strengthening the association between current samples and choices. These results are incompatible with a trace-decay and competition model; they suggest strongly that multiple influences act simultaneously and independently to control delayed matching-to-sample responding. These multiple influences include memory for the choice occurring on the previous trial, memory for the sample, and general effects of trial spacing.

  15. The finite sample performance of estimators for mediation analysis under sequential conditional independence

    DEFF Research Database (Denmark)

    Huber, Martin; Lechner, Michael; Mellace, Giovanni

    Using a comprehensive simulation study based on empirical data, this paper investigates the finite sample properties of different classes of parametric and semi-parametric estimators of (natural) direct and indirect causal effects used in mediation analysis under sequential conditional independence...

  16. The finite sample performance of estimators for mediation analysis under sequential conditional independence

    DEFF Research Database (Denmark)

    Huber, Martin; Lechner, Michael; Mellace, Giovanni

    2016-01-01

    Using a comprehensive simulation study based on empirical data, this paper investigates the finite sample properties of different classes of parametric and semi-parametric estimators of (natural) direct and indirect causal effects used in mediation analysis under sequential conditional independen...... of the methods often (but not always) varies with the features of the data generating process....

  17. Radioenzymatic assay for trimethoprim in very small serum samples.

    OpenAIRE

    Yogev, R; Melick, C; Tan-Pong, L

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved.

  18. Radioenzymatic assay for trimethoprim in very small serum samples

    International Nuclear Information System (INIS)

    Yogev, R.; Melick, C.; Tan-Pong, L.

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved

  19. A Sequential Optimization Sampling Method for Metamodels with Radial Basis Functions

    Science.gov (United States)

    Pan, Guang; Ye, Pengcheng; Yang, Zhidong

    2014-01-01

    Metamodels have been widely used in engineering design to facilitate analysis and optimization of complex systems that involve computationally expensive simulation programs. The accuracy of metamodels is strongly affected by the sampling methods. In this paper, a new sequential optimization sampling method is proposed. Based on the new sampling method, metamodels can be constructed repeatedly through the addition of sampling points, namely, extrema points of metamodels and minimum points of density function. Afterwards, the more accurate metamodels would be constructed by the procedure above. The validity and effectiveness of proposed sampling method are examined by studying typical numerical examples. PMID:25133206

  20. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Directory of Open Access Journals (Sweden)

    Angelica Maldonado-Rodríguez

    2017-01-01

    Full Text Available Background. Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs. Methods. Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x. The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.

  1. Sequential Sampling Plan of Anthonomus grandis (Coleoptera: Curculionidae) in Cotton Plants.

    Science.gov (United States)

    Grigolli, J F J; Souza, L A; Mota, T A; Fernandes, M G; Busoli, A C

    2017-04-01

    The boll weevil, Anthonomus grandis grandis Boheman (Coleoptera: Curculionidae), is one of the most important pests of cotton production worldwide. The objective of this work was to develop a sequential sampling plan for the boll weevil. The studies were conducted in Maracaju, MS, Brazil, in two seasons with cotton cultivar FM 993. A 10,000-m2 area of cotton was subdivided into 100 of 10- by 10-m plots, and five plants per plot were evaluated weekly, recording the number of squares with feeding + oviposition punctures of A. grandis in each plant. A sequential sampling plan by the maximum likelihood ratio test was developed, using a 10% threshold level of squares attacked. A 5% security level was adopted for the elaboration of the sequential sampling plan. The type I and type II error used was 0.05, recommended for studies with insects. The adjustment of the frequency distributions used were divided into two phases, so that the model that best fit to the data was the negative binomial distribution up to 85 DAE (Phase I), and from there the best fit was Poisson distribution (Phase II). The equations that define the decision-making for Phase I are S0 = -5.1743 + 0.5730N and S1 = 5.1743 + 0.5730N, and for the Phase II are S0 = -4.2479 + 0.5771N and S1 = 4.2479 + 0.5771N. The sequential sampling plan developed indicated the maximum number of sample units expected for decision-making is ∼39 and 31 samples for Phases I and II, respectively. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Parameter sampling capabilities of sequential and simultaneous data assimilation: I. Analytical comparison

    International Nuclear Information System (INIS)

    Fossum, Kristian; Mannseth, Trond

    2014-01-01

    We assess the parameter sampling capabilities of some Bayesian, ensemble-based, joint state-parameter (JS) estimation methods. The forward model is assumed to be non-chaotic and have nonlinear components, and the emphasis is on results obtained for the parameters in the state-parameter vector. A variety of approximate sampling methods exist, and a number of numerical comparisons between such methods have been performed. Often, more than one of the defining characteristics vary from one method to another, so it can be difficult to point out which characteristic of the more successful method in such a comparison was decisive. In this study, we single out one defining characteristic for comparison; whether or not data are assimilated sequentially or simultaneously. The current paper is concerned with analytical investigations into this issue. We carefully select one sequential and one simultaneous JS method for the comparison. We also design a corresponding pair of pure parameter estimation methods, and we show how the JS methods and the parameter estimation methods are pairwise related. It is shown that the sequential and the simultaneous parameter estimation methods are equivalent for one particular combination of observations with different degrees of nonlinearity. Strong indications are presented for why one may expect the sequential parameter estimation method to outperform the simultaneous parameter estimation method for all other combinations of observations. Finally, the conditions for when similar relations can be expected to hold between the corresponding JS methods are discussed. A companion paper, part II (Fossum and Mannseth 2014 Inverse Problems 30 114003), is concerned with statistical analysis of results from a range of numerical experiments involving sequential and simultaneous JS estimation, where the design of the numerical investigation is motivated by our findings in the current paper. (paper)

  3. Plane-Based Sampling for Ray Casting Algorithm in Sequential Medical Images

    Science.gov (United States)

    Lin, Lili; Chen, Shengyong; Shao, Yan; Gu, Zichun

    2013-01-01

    This paper proposes a plane-based sampling method to improve the traditional Ray Casting Algorithm (RCA) for the fast reconstruction of a three-dimensional biomedical model from sequential images. In the novel method, the optical properties of all sampling points depend on the intersection points when a ray travels through an equidistant parallel plan cluster of the volume dataset. The results show that the method improves the rendering speed at over three times compared with the conventional algorithm and the image quality is well guaranteed. PMID:23424608

  4. Sequential sampling and biorational chemistries for management of lepidopteran pests of vegetable amaranth in the Caribbean.

    Science.gov (United States)

    Clarke-Harris, Dionne; Fleischer, Shelby J

    2003-06-01

    Although vegetable amaranth, Amaranthus viridis L. and A. dubius Mart. ex Thell., production and economic importance is increasing in diversified peri-urban farms in Jamaica, lepidopteran herbivory is common even during weekly pyrethroid applications. We developed and validated a sampling plan, and investigated insecticides with new modes of action, for a complex of five species (Pyralidae: Spoladea recurvalis (F.), Herpetogramma bipunctalis (F.), Noctuidae: Spodoptera exigua (Hubner), S. frugiperda (J. E. Smith), and S. eridania Stoll). Significant within-plant variation occurred with H. bipunctalis, and a six-leaf sample unit including leaves from the inner and outer whorl was selected to sample all species. Larval counts best fit a negative binomial distribution. We developed a sequential sampling plan using a threshold of one larva per sample unit and the fitted distribution with a k(c) of 0.645. When compared with a fixed plan of 25 plants, sequential sampling recommended the same management decision on 87.5%, additional samples on 9.4%, and gave inaccurate recommendations on 3.1% of 32 farms, while reducing sample size by 46%. Insecticide frequency was reduced 33-60% when management decisions were based on sampled data compared with grower-standards, with no effect on crop damage. Damage remained high or variable (10-46%) with pyrethroid applications. Lepidopteran control was dramatically improved with ecdysone agonists (tebufenozide) or microbial metabolites (spinosyns and emamectin benzoate). This work facilitates resistance management efforts concurrent with the introduction of newer modes of action for lepidopteran control in leafy vegetable production in the Caribbean.

  5. Parameter sampling capabilities of sequential and simultaneous data assimilation: II. Statistical analysis of numerical results

    International Nuclear Information System (INIS)

    Fossum, Kristian; Mannseth, Trond

    2014-01-01

    We assess and compare parameter sampling capabilities of one sequential and one simultaneous Bayesian, ensemble-based, joint state-parameter (JS) estimation method. In the companion paper, part I (Fossum and Mannseth 2014 Inverse Problems 30 114002), analytical investigations lead us to propose three claims, essentially stating that the sequential method can be expected to outperform the simultaneous method for weakly nonlinear forward models. Here, we assess the reliability and robustness of these claims through statistical analysis of results from a range of numerical experiments. Samples generated by the two approximate JS methods are compared to samples from the posterior distribution generated by a Markov chain Monte Carlo method, using four approximate measures of distance between probability distributions. Forward-model nonlinearity is assessed from a stochastic nonlinearity measure allowing for sufficiently large model dimensions. Both toy models (with low computational complexity, and where the nonlinearity is fairly easy to control) and two-phase porous-media flow models (corresponding to down-scaled versions of problems to which the JS methods have been frequently applied recently) are considered in the numerical experiments. Results from the statistical analysis show strong support of all three claims stated in part I. (paper)

  6. Sampling informative/complex a priori probability distributions using Gibbs sampling assisted by sequential simulation

    DEFF Research Database (Denmark)

    Hansen, Thomas Mejer; Mosegaard, Klaus; Cordua, Knud Skou

    2010-01-01

    Markov chain Monte Carlo methods such as the Gibbs sampler and the Metropolis algorithm can be used to sample the solutions to non-linear inverse problems. In principle these methods allow incorporation of arbitrarily complex a priori information, but current methods allow only relatively simple...... this algorithm with the Metropolis algorithm to obtain an efficient method for sampling posterior probability densities for nonlinear inverse problems....

  7. A novel approach for small sample size family-based association studies: sequential tests.

    Science.gov (United States)

    Ilk, Ozlem; Rajabli, Farid; Dungul, Dilay Ciglidag; Ozdag, Hilal; Ilk, Hakki Gokhan

    2011-08-01

    In this paper, we propose a sequential probability ratio test (SPRT) to overcome the problem of limited samples in studies related to complex genetic diseases. The results of this novel approach are compared with the ones obtained from the traditional transmission disequilibrium test (TDT) on simulated data. Although TDT classifies single-nucleotide polymorphisms (SNPs) to only two groups (SNPs associated with the disease and the others), SPRT has the flexibility of assigning SNPs to a third group, that is, those for which we do not have enough evidence and should keep sampling. It is shown that SPRT results in smaller ratios of false positives and negatives, as well as better accuracy and sensitivity values for classifying SNPs when compared with TDT. By using SPRT, data with small sample size become usable for an accurate association analysis.

  8. A Sequential Kriging reliability analysis method with characteristics of adaptive sampling regions and parallelizability

    International Nuclear Information System (INIS)

    Wen, Zhixun; Pei, Haiqing; Liu, Hai; Yue, Zhufeng

    2016-01-01

    The sequential Kriging reliability analysis (SKRA) method has been developed in recent years for nonlinear implicit response functions which are expensive to evaluate. This type of method includes EGRA: the efficient reliability analysis method, and AK-MCS: the active learning reliability method combining Kriging model and Monte Carlo simulation. The purpose of this paper is to improve SKRA by adaptive sampling regions and parallelizability. The adaptive sampling regions strategy is proposed to avoid selecting samples in regions where the probability density is so low that the accuracy of these regions has negligible effects on the results. The size of the sampling regions is adapted according to the failure probability calculated by last iteration. Two parallel strategies are introduced and compared, aimed at selecting multiple sample points at a time. The improvement is verified through several troublesome examples. - Highlights: • The ISKRA method improves the efficiency of SKRA. • Adaptive sampling regions strategy reduces the number of needed samples. • The two parallel strategies reduce the number of needed iterations. • The accuracy of the optimal value impacts the number of samples significantly.

  9. Spatial distribution and sequential sampling plans for Tuta absoluta (Lepidoptera: Gelechiidae) in greenhouse tomato crops.

    Science.gov (United States)

    Cocco, Arturo; Serra, Giuseppe; Lentini, Andrea; Deliperi, Salvatore; Delrio, Gavino

    2015-09-01

    The within- and between-plant distribution of the tomato leafminer, Tuta absoluta (Meyrick), was investigated in order to define action thresholds based on leaf infestation and to propose enumerative and binomial sequential sampling plans for pest management applications in protected crops. The pest spatial distribution was aggregated between plants, and median leaves were the most suitable sample to evaluate the pest density. Action thresholds of 36 and 48%, 43 and 56% and 60 and 73% infested leaves, corresponding to economic thresholds of 1 and 3% damaged fruits, were defined for tomato cultivars with big, medium and small fruits respectively. Green's method was a more suitable enumerative sampling plan as it required a lower sampling effort. Binomial sampling plans needed lower average sample sizes than enumerative plans to make a treatment decision, with probabilities of error of sampling plan required 87 or 343 leaves to estimate the population density in extensive or intensive ecological studies respectively. Binomial plans would be more practical and efficient for control purposes, needing average sample sizes of 17, 20 and 14 leaves to take a pest management decision in order to avoid fruit damage higher than 1% in cultivars with big, medium and small fruits respectively. © 2014 Society of Chemical Industry.

  10. Utilizing a sequential injection system furnished with an extraction microcolumn as a novel approach for executing sequential extractions of metal species in solid samples

    DEFF Research Database (Denmark)

    Chomchoei, R.; Hansen, Elo Harald; Shiowatana, J.

    2007-01-01

    This communication presents a novel approach to perform sequential extraction of elements in solid samples by using a sequential injection (SI) system incorporating a specially designed extraction microcolumn. Based on the operation of the syringe pump, different modes of extraction are potentially...... that the system entails many advantages such as being fully automated, and besides being characterised by rapidity, ease of operation and robustness, it is less prone to risks of contamination and personal errors as encountered in traditional batch systems. Moreover, improvement of the precision and accuracy...... of the chemical fractionation of metal in solids as compared with previous reports are obtained. The system ensures that extraction is performed at designated pH values. Variation of sample weight to column volume ratios do not affect the amounts of extractable metals, nor do extraction flow rates ranging from 50...

  11. Inverse problems with non-trivial priors: efficient solution through sequential Gibbs sampling

    DEFF Research Database (Denmark)

    Hansen, Thomas Mejer; Cordua, Knud Skou; Mosegaard, Klaus

    2012-01-01

    Markov chain Monte Carlo methods such as the Gibbs sampler and the Metropolis algorithm can be used to sample solutions to non-linear inverse problems. In principle, these methods allow incorporation of prior information of arbitrary complexity. If an analytical closed form description of the prior...... is available, which is the case when the prior can be described by a multidimensional Gaussian distribution, such prior information can easily be considered. In reality, prior information is often more complex than can be described by the Gaussian model, and no closed form expression of the prior can be given....... We propose an algorithm, called sequential Gibbs sampling, allowing the Metropolis algorithm to efficiently incorporate complex priors into the solution of an inverse problem, also for the case where no closed form description of the prior exists. First, we lay out the theoretical background...

  12. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  13. Testing sequential extraction methods for the analysis of multiple stable isotope systems from a bone sample

    Science.gov (United States)

    Sahlstedt, Elina; Arppe, Laura

    2017-04-01

    Stable isotope composition of bones, analysed either from the mineral phase (hydroxyapatite) or from the organic phase (mainly collagen) carry important climatological and ecological information and are therefore widely used in paleontological and archaeological research. For the analysis of the stable isotope compositions, both of the phases, hydroxyapatite and collagen, have their more or less well established separation and analytical techniques. Recent development in IRMS and wet chemical extraction methods have facilitated the analysis of very small bone fractions (500 μg or less starting material) for PO43-O isotope composition. However, the uniqueness and (pre-) historical value of each archaeological and paleontological finding lead to preciously little material available for stable isotope analyses, encouraging further development of microanalytical methods for the use of stable isotope analyses. Here we present the first results in developing extraction methods for combining collagen C- and N-isotope analyses to PO43-O-isotope analyses from a single bone sample fraction. We tested sequential extraction starting with dilute acid demineralization and collection of both collagen and PO43-fractions, followed by further purification step by H2O2 (PO43-fraction). First results show that bone sample separates as small as 2 mg may be analysed for their δ15N, δ13C and δ18OPO4 values. The method may be incorporated in detailed investigation of sequentially developing skeletal material such as teeth, potentially allowing for the investigation of interannual variability in climatological/environmental signals or investigation of the early life history of an individual.

  14. Comparing cluster-level dynamic treatment regimens using sequential, multiple assignment, randomized trials: Regression estimation and sample size considerations.

    Science.gov (United States)

    NeCamp, Timothy; Kilbourne, Amy; Almirall, Daniel

    2017-08-01

    Cluster-level dynamic treatment regimens can be used to guide sequential treatment decision-making at the cluster level in order to improve outcomes at the individual or patient-level. In a cluster-level dynamic treatment regimen, the treatment is potentially adapted and re-adapted over time based on changes in the cluster that could be impacted by prior intervention, including aggregate measures of the individuals or patients that compose it. Cluster-randomized sequential multiple assignment randomized trials can be used to answer multiple open questions preventing scientists from developing high-quality cluster-level dynamic treatment regimens. In a cluster-randomized sequential multiple assignment randomized trial, sequential randomizations occur at the cluster level and outcomes are observed at the individual level. This manuscript makes two contributions to the design and analysis of cluster-randomized sequential multiple assignment randomized trials. First, a weighted least squares regression approach is proposed for comparing the mean of a patient-level outcome between the cluster-level dynamic treatment regimens embedded in a sequential multiple assignment randomized trial. The regression approach facilitates the use of baseline covariates which is often critical in the analysis of cluster-level trials. Second, sample size calculators are derived for two common cluster-randomized sequential multiple assignment randomized trial designs for use when the primary aim is a between-dynamic treatment regimen comparison of the mean of a continuous patient-level outcome. The methods are motivated by the Adaptive Implementation of Effective Programs Trial which is, to our knowledge, the first-ever cluster-randomized sequential multiple assignment randomized trial in psychiatry.

  15. Solid phase speciation of arsenic by sequential extraction in standard reference materials and industrially contaminated soil samples

    International Nuclear Information System (INIS)

    Herreweghe, Samuel van; Swennen, Rudy; Vandecasteele, Carlo; Cappuyns, Valerie

    2003-01-01

    Leaching experiments, a mineralogical survey and larger samples are preferred when arsenic is present as discrete mineral phases. - Availability, mobility, (phyto)toxicity and potential risk of contaminants is strongly affected by the manner of appearance of elements, the so-called speciation. Operational fractionation methods like sequential extractions have been applied for a long time to determine the solid phase speciation of heavy metals since direct determination of specific chemical compounds can not always be easily achieved. The three-step sequential extraction scheme recommended by the BCR and two extraction schemes based on the phosphorus-like protocol proposed by Manful (1992, Occurrence and Ecochemical Behaviours of Arsenic in a Goldsmelter Impacted Area in Ghana, PhD dissertation, at the RUG) were applied to four standard reference materials (SRM) and to a batch of samples from industrially contaminated sites, heavily contaminated with arsenic and heavy metals. The SRM 2710 (Montana soil) was found to be the most useful reference material for metal (Mn, Cu, Zn, As, Cd and Pb) fractionation using the BCR sequential extraction procedure. Two sequential extraction schemes were developed and compared for arsenic with the aim to establish a better fractionation and recovery rate than the BCR-scheme for this element in the SRM samples. The major part of arsenic was released from the heavily contaminated samples after NaOH-extraction. Inferior extraction variability and recovery in the heavily contaminated samples compared to SRMs could be mainly contributed to subsample heterogeneity

  16. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2005-01-01

    Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e.,Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments in ...

  17. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  18. Value-based decision making via sequential sampling with hierarchical competition and attentional modulation.

    Science.gov (United States)

    Colas, Jaron T

    2017-01-01

    In principle, formal dynamical models of decision making hold the potential to represent fundamental computations underpinning value-based (i.e., preferential) decisions in addition to perceptual decisions. Sequential-sampling models such as the race model and the drift-diffusion model that are grounded in simplicity, analytical tractability, and optimality remain popular, but some of their more recent counterparts have instead been designed with an aim for more feasibility as architectures to be implemented by actual neural systems. Connectionist models are proposed herein at an intermediate level of analysis that bridges mental phenomena and underlying neurophysiological mechanisms. Several such models drawing elements from the established race, drift-diffusion, feedforward-inhibition, divisive-normalization, and competing-accumulator models were tested with respect to fitting empirical data from human participants making choices between foods on the basis of hedonic value rather than a traditional perceptual attribute. Even when considering performance at emulating behavior alone, more neurally plausible models were set apart from more normative race or drift-diffusion models both quantitatively and qualitatively despite remaining parsimonious. To best capture the paradigm, a novel six-parameter computational model was formulated with features including hierarchical levels of competition via mutual inhibition as well as a static approximation of attentional modulation, which promotes "winner-take-all" processing. Moreover, a meta-analysis encompassing several related experiments validated the robustness of model-predicted trends in humans' value-based choices and concomitant reaction times. These findings have yet further implications for analysis of neurophysiological data in accordance with computational modeling, which is also discussed in this new light.

  19. Value-based decision making via sequential sampling with hierarchical competition and attentional modulation.

    Directory of Open Access Journals (Sweden)

    Jaron T Colas

    Full Text Available In principle, formal dynamical models of decision making hold the potential to represent fundamental computations underpinning value-based (i.e., preferential decisions in addition to perceptual decisions. Sequential-sampling models such as the race model and the drift-diffusion model that are grounded in simplicity, analytical tractability, and optimality remain popular, but some of their more recent counterparts have instead been designed with an aim for more feasibility as architectures to be implemented by actual neural systems. Connectionist models are proposed herein at an intermediate level of analysis that bridges mental phenomena and underlying neurophysiological mechanisms. Several such models drawing elements from the established race, drift-diffusion, feedforward-inhibition, divisive-normalization, and competing-accumulator models were tested with respect to fitting empirical data from human participants making choices between foods on the basis of hedonic value rather than a traditional perceptual attribute. Even when considering performance at emulating behavior alone, more neurally plausible models were set apart from more normative race or drift-diffusion models both quantitatively and qualitatively despite remaining parsimonious. To best capture the paradigm, a novel six-parameter computational model was formulated with features including hierarchical levels of competition via mutual inhibition as well as a static approximation of attentional modulation, which promotes "winner-take-all" processing. Moreover, a meta-analysis encompassing several related experiments validated the robustness of model-predicted trends in humans' value-based choices and concomitant reaction times. These findings have yet further implications for analysis of neurophysiological data in accordance with computational modeling, which is also discussed in this new light.

  20. Value-based decision making via sequential sampling with hierarchical competition and attentional modulation

    Science.gov (United States)

    2017-01-01

    In principle, formal dynamical models of decision making hold the potential to represent fundamental computations underpinning value-based (i.e., preferential) decisions in addition to perceptual decisions. Sequential-sampling models such as the race model and the drift-diffusion model that are grounded in simplicity, analytical tractability, and optimality remain popular, but some of their more recent counterparts have instead been designed with an aim for more feasibility as architectures to be implemented by actual neural systems. Connectionist models are proposed herein at an intermediate level of analysis that bridges mental phenomena and underlying neurophysiological mechanisms. Several such models drawing elements from the established race, drift-diffusion, feedforward-inhibition, divisive-normalization, and competing-accumulator models were tested with respect to fitting empirical data from human participants making choices between foods on the basis of hedonic value rather than a traditional perceptual attribute. Even when considering performance at emulating behavior alone, more neurally plausible models were set apart from more normative race or drift-diffusion models both quantitatively and qualitatively despite remaining parsimonious. To best capture the paradigm, a novel six-parameter computational model was formulated with features including hierarchical levels of competition via mutual inhibition as well as a static approximation of attentional modulation, which promotes “winner-take-all” processing. Moreover, a meta-analysis encompassing several related experiments validated the robustness of model-predicted trends in humans’ value-based choices and concomitant reaction times. These findings have yet further implications for analysis of neurophysiological data in accordance with computational modeling, which is also discussed in this new light. PMID:29077746

  1. Sequential capillary electrophoresis analysis using optically gated sample injection and UV/vis detection.

    Science.gov (United States)

    Liu, Xiaoxia; Tian, Miaomiao; Camara, Mohamed Amara; Guo, Liping; Yang, Li

    2015-10-01

    We present sequential CE analysis of amino acids and L-asparaginase-catalyzed enzyme reaction, by combing the on-line derivatization, optically gated (OG) injection and commercial-available UV-Vis detection. Various experimental conditions for sequential OG-UV/vis CE analysis were investigated and optimized by analyzing a standard mixture of amino acids. High reproducibility of the sequential CE analysis was demonstrated with RSD values (n = 20) of 2.23, 2.57, and 0.70% for peak heights, peak areas, and migration times, respectively, and the LOD of 5.0 μM (for asparagine) and 2.0 μM (for aspartic acid) were obtained. With the application of the OG-UV/vis CE analysis, sequential online CE enzyme assay of L-asparaginase-catalyzed enzyme reaction was carried out by automatically and continuously monitoring the substrate consumption and the product formation every 12 s from the beginning to the end of the reaction. The Michaelis constants for the reaction were obtained and were found to be in good agreement with the results of traditional off-line enzyme assays. The study demonstrated the feasibility and reliability of integrating the OG injection with UV/vis detection for sequential online CE analysis, which could be of potential value for online monitoring various chemical reaction and bioprocesses. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. A sequential sampling account of response bias and speed-accuracy tradeoffs in a conflict detection task.

    Science.gov (United States)

    Vuckovic, Anita; Kwantes, Peter J; Humphreys, Michael; Neal, Andrew

    2014-03-01

    Signal Detection Theory (SDT; Green & Swets, 1966) is a popular tool for understanding decision making. However, it does not account for the time taken to make a decision, nor why response bias might change over time. Sequential sampling models provide a way of accounting for speed-accuracy trade-offs and response bias shifts. In this study, we test the validity of a sequential sampling model of conflict detection in a simulated air traffic control task by assessing whether two of its key parameters respond to experimental manipulations in a theoretically consistent way. Through experimental instructions, we manipulated participants' response bias and the relative speed or accuracy of their responses. The sequential sampling model was able to replicate the trends in the conflict responses as well as response time across all conditions. Consistent with our predictions, manipulating response bias was associated primarily with changes in the model's Criterion parameter, whereas manipulating speed-accuracy instructions was associated with changes in the Threshold parameter. The success of the model in replicating the human data suggests we can use the parameters of the model to gain an insight into the underlying response bias and speed-accuracy preferences common to dynamic decision-making tasks. © 2013 American Psychological Association

  3. Demonstration of a longitudinal concentration gradient along scala tympani by sequential sampling of perilymph from the cochlear apex.

    Science.gov (United States)

    Mynatt, Robert; Hale, Shane A; Gill, Ruth M; Plontke, Stefan K; Salt, Alec N

    2006-06-01

    Local applications of drugs to the inner ear are increasingly being used to treat patients' inner ear disorders. Knowledge of the pharmacokinetics of drugs in the inner ear fluids is essential for a scientific basis for such treatments. When auditory function is of primary interest, the drug's kinetics in scala tympani (ST) must be established. Measurement of drug levels in ST is technically difficult because of the known contamination of perilymph samples taken from the basal cochlear turn with cerebrospinal fluid (CSF). Recently, we reported a technique in which perilymph was sampled from the cochlear apex to minimize the influence of CSF contamination (J. Neurosci. Methods, doi: 10.1016/j.jneumeth.2005.10.008 ). This technique has now been extended by taking smaller fluid samples sequentially from the cochlear apex, which can be used to quantify drug gradients along ST. The sampling and analysis methods were evaluated using an ionic marker, trimethylphenylammonium (TMPA), that was applied to the round window membrane. After loading perilymph with TMPA, 10 1-muL samples were taken from the cochlear apex. The TMPA content of the samples was consistent with the first sample containing perilymph from apical regions and the fourth or fifth sample containing perilymph from the basal turn. TMPA concentration decreased in subsequent samples, as they increasingly contained CSF that had passed through ST. Sample concentration curves were interpreted quantitatively by simulation of the experiment with a finite element model and by an automated curve-fitting method by which the apical-basal gradient was estimated. The study demonstrates that sequential apical sampling provides drug gradient data for ST perilymph while avoiding the major distortions of sample composition associated with basal turn sampling. The method can be used for any substance for which a sensitive assay is available and is therefore of high relevance for the development of preclinical and clinical

  4. Sequential injection titration method using second-order signals: determination of acidity in plant oils and biodiesel samples.

    Science.gov (United States)

    del Río, Vanessa; Larrechi, M Soledad; Callao, M Pilar

    2010-06-15

    A new concept of flow titration is proposed and demonstrated for the determination of total acidity in plant oils and biodiesel. We use sequential injection analysis (SIA) with a diode array spectrophotometric detector linked to chemometric tools such as multivariate curve resolution-alternating least squares (MCR-ALS). This system is based on the evolution of the basic specie of an acid-base indicator, alizarine, when it comes into contact with a sample that contains free fatty acids. The gradual pH change in the reactor coil due to diffusion and reaction phenomenona allows the sequential appearance of both species of the indicator in the detector coil, recording a data matrix for each sample. The SIA-MCR-ALS method helps to reduce the amounts of sample, the reagents and the time consumed. Each determination consumes 0.413ml of sample, 0.250ml of indicator and 3ml of carrier (ethanol) and generates 3.333ml of waste. The frequency of the analysis is high (12 samples h(-1) including all steps, i.e., cleaning, preparing and analysing). The utilized reagents are of common use in the laboratory and it is not necessary to use the reagents of perfect known concentration. The method was applied to determine acidity in plant oil and biodiesel samples. Results obtained by the proposed method compare well with those obtained by the official European Community method that is time consuming and uses large amounts of organic solvents.

  5. A Fixed-Precision Sequential Sampling Plan for the Potato Tuberworm Moth, Phthorimaea operculella Zeller (Lepidoptera: Gelechidae), on Potato Cultivars.

    Science.gov (United States)

    Shahbi, M; Rajabpour, A

    2017-08-01

    Phthorimaea operculella Zeller is an important pest of potato in Iran. Spatial distribution and fixed-precision sequential sampling for population estimation of the pest on two potato cultivars, Arinda ® and Sante ® , were studied in two separate potato fields during two growing seasons (2013-2014 and 2014-2015). Spatial distribution was investigated by Taylor's power law and Iwao's patchiness. Results showed that the spatial distribution of eggs and larvae was random. In contrast to Iwao's patchiness, Taylor's power law provided a highly significant relationship between variance and mean density. Therefore, fixed-precision sequential sampling plan was developed by Green's model at two precision levels of 0.25 and 0.1. The optimum sample size on Arinda ® and Sante ® cultivars at precision level of 0.25 ranged from 151 to 813 and 149 to 802 leaves, respectively. At 0.1 precision level, the sample sizes varied from 5083 to 1054 and 5100 to 1050 leaves for Arinda ® and Sante ® cultivars, respectively. Therefore, the optimum sample sizes for the cultivars, with different resistance levels, were not significantly different. According to the calculated stop lines, the sampling must be continued until cumulative number of eggs + larvae reached to 15-16 or 96-101 individuals at precision levels of 0.25 or 0.1, respectively. The performance of the sampling plan was validated by resampling analysis using resampling for validation of sampling plans software. The sampling plant provided in this study can be used to obtain a rapid estimate of the pest density with minimal effort.

  6. Clinical, radiological and molecular diagnosis correlation in serum samples from patients with osteoarticular tuberculosis

    Directory of Open Access Journals (Sweden)

    Guadalupe García-Elorriaga

    2014-07-01

    Conclusions: Nested PCR in serum samples is a rapid, highly sensitive and specific modality for OTB detection. PCR should be performed in addition to clinical evaluation, imaging studies, acid-fast bacilli staining, culture and histopathology diagnosis, if possible.

  7. Pre-analytical sample quality: metabolite ratios as an intrinsic marker for prolonged room temperature exposure of serum samples.

    Directory of Open Access Journals (Sweden)

    Gabriele Anton

    Full Text Available Advances in the "omics" field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between 'good' and 'bad' quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between 'good' and 'bad' quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation.

  8. Sequential extraction procedure for determination of uranium, thorium, radium, lead and polonium radionuclides by alpha spectrometry in environmental samples

    Science.gov (United States)

    Oliveira, J. M.; Carvalho, F. P.

    2006-01-01

    A sequential extraction technique was developed and tested for common naturally-occurring radionuclides. This technique allows the extraction and purification of uranium, thorium, radium, lead, and polonium radionuclides from the same sample. Environmental materials such as water, soil, and biological samples can be analyzed for those radionuclides without matrix interferences in the quality of radioelement purification and in the radiochemical yield. The use of isotopic tracers (232U, 229Th, 224Ra, 209Po, and stable lead carrier) added to the sample in the beginning of the chemical procedure, enables an accurate control of the radiochemical yield for each radioelement. The ion extraction procedure, applied after either complete dissolution of the solid sample with mineral acids or co-precipitation of dissolved radionuclide with MnO2 for aqueous samples, includes the use of commercially available pre-packed columns from Eichrom® and ion exchange columns packed with Bio-Rad resins, in altogether three chromatography columns. All radioactive elements but one are purified and electroplated on stainless steel discs. Polonium is spontaneously plated on a silver disc. The discs are measured using high resolution silicon surface barrier detectors. 210Pb, a beta emitter, can be measured either through the beta emission of 210Bi, or stored for a few months and determined by alpha spectrometry through the in-growth of 210Po. This sequential extraction chromatography technique was tested and validated with the analysis of certified reference materials from the IAEA. Reproducibility was tested through repeated analysis of the same homogeneous material (water sample).

  9. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  10. A method for multiple sequential analyses of macrophage functions using a small single cell sample

    Directory of Open Access Journals (Sweden)

    F.R.F. Nascimento

    2003-09-01

    Full Text Available Microbial pathogens such as bacillus Calmette-Guérin (BCG induce the activation of macrophages. Activated macrophages can be characterized by the increased production of reactive oxygen and nitrogen metabolites, generated via NADPH oxidase and inducible nitric oxide synthase, respectively, and by the increased expression of major histocompatibility complex class II molecules (MHC II. Multiple microassays have been developed to measure these parameters. Usually each assay requires 2-5 x 10(5 cells per well. In some experimental conditions the number of cells is the limiting factor for the phenotypic characterization of macrophages. Here we describe a method whereby this limitation can be circumvented. Using a single 96-well microassay and a very small number of peritoneal cells obtained from C3H/HePas mice, containing as little as <=2 x 10(5 macrophages per well, we determined sequentially the oxidative burst (H2O2, nitric oxide production and MHC II (IAk expression of BCG-activated macrophages. More specifically, with 100 µl of cell suspension it was possible to quantify H2O2 release and nitric oxide production after 1 and 48 h, respectively, and IAk expression after 48 h of cell culture. In addition, this microassay is easy to perform, highly reproducible and more economical.

  11. An Efficient Constraint Boundary Sampling Method for Sequential RBDO Using Kriging Surrogate Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jihoon; Jang, Junyong; Kim, Shinyu; Lee, Tae Hee [Hanyang Univ., Seoul (Korea, Republic of); Cho, Sugil; Kim, Hyung Woo; Hong, Sup [Korea Research Institute of Ships and Ocean Engineering, Busan (Korea, Republic of)

    2016-06-15

    Reliability-based design optimization (RBDO) requires a high computational cost owing to its reliability analysis. A surrogate model is introduced to reduce the computational cost in RBDO. The accuracy of the reliability depends on the accuracy of the surrogate model of constraint boundaries in the surrogated-model-based RBDO. In earlier researches, constraint boundary sampling (CBS) was proposed to approximate accurately the boundaries of constraints by locating sample points on the boundaries of constraints. However, because CBS uses sample points on all constraint boundaries, it creates superfluous sample points. In this paper, efficient constraint boundary sampling (ECBS) is proposed to enhance the efficiency of CBS. ECBS uses the statistical information of a kriging surrogate model to locate sample points on or near the RBDO solution. The efficiency of ECBS is verified by mathematical examples.

  12. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  13. Adaptive list sequential sampling method for population-based observational studies

    NARCIS (Netherlands)

    Hof, Michel H.; Ravelli, Anita C. J.; Zwinderman, Aeilko H.

    2014-01-01

    In population-based observational studies, non-participation and delayed response to the invitation to participate are complications that often arise during the recruitment of a sample. When both are not properly dealt with, the composition of the sample can be different from the desired

  14. Comparison of miRNA quantitation by Nanostring in serum and plasma samples.

    Directory of Open Access Journals (Sweden)

    Catherine Foye

    Full Text Available Circulating microRNAs that are associated with specific diseases have garnered much attention for use in diagnostic assays. However, detection of disease-associated miRNA can be affected by several factors such as release of contaminating cellular miRNA during sample collection, variations due to amplification of transcript for detection, or controls used for normalization for accurate quantitation. We analyzed circulating miRNA in serum and plasma samples obtained concurrently from 28 patients, using a Nanostring quantitative assay platform. Total RNA concentration ranged from 32-125 μg/ml from serum and 30-220 μg/ml from plasma. Of 798 miRNAs, 371 miRNAs were not detected in either serum or plasma samples. 427 were detected in either serum or plasma but not both, whereas 151 miRNA were detected in both serum and plasma samples. The diversity of miRNA detected was greater in plasma than in serum samples. In serum samples, the number of detected miRNA ranged from 3 to 82 with a median of 17, whereas in plasma samples, the number of miRNA detected ranged from 25 to 221 with a median of 91. Several miRNA such as miR451a, miR 16-5p, miR-223-3p, and mir25-3p were highly abundant and differentially expressed between serum and plasma. The detection of endogenous and exogenous control miRNAs varied in serum and plasma, with higher levels observed in plasma. Gene expression stability identified candidate invariant microRNA that were highly stable across all samples, and could be used for normalization. In conclusion, there are significant differences in both the number of miRNA detected and the amount of miRNA detected between serum and plasma. Normalization using miRNA with constant expression is essential to minimize the impact of technical variations. Given the challenges involved, ideal candidates for blood based biomarkers would be those that are indifferent to type of body fluid, are detectable and can be reliably quantitated.

  15. Sequential automated fusion/extraction chromatography methodology for the dissolution of uranium in environmental samples for mass spectrometric determination

    Energy Technology Data Exchange (ETDEWEB)

    Milliard, Alex; Durand-Jezequel, Myriam [Laboratoire de Radioecologie, Departement de chimie, Universite Laval, 1045 Avenue de la Medecine, Quebec, QC, G1V 0A6 (Canada); Lariviere, Dominic, E-mail: dominic.lariviere@chm.ulaval.ca [Laboratoire de Radioecologie, Departement de chimie, Universite Laval, 1045 Avenue de la Medecine, Quebec, QC, G1V 0A6 (Canada)

    2011-01-17

    An improved methodology has been developed, based on dissolution by automated fusion followed by extraction chromatography for the detection and quantification of uranium in environmental matrices by mass spectrometry. A rapid fusion protocol (<8 min) was investigated for the complete dissolution of various samples. It could be preceded, if required, by an effective ashing procedure using the M4 fluxer and a newly designed platinum lid. Complete dissolution of the sample was observed and measured using standard reference materials (SRMs) and experimental data show no evidence of cross-contamination of crucibles when LiBO{sub 2}/LiBr melts were used. The use of a M4 fusion unit also improved repeatability in sample preparation over muffle furnace fusion. Instrumental issues originating from the presence of high salt concentrations in the digestate after lithium metaborate fusion was also mitigated using an extraction chromatography (EXC) protocol aimed at removing lithium and interfering matrix constituants prior to the elution of uranium. The sequential methodology, which can be performed simultaneously on three samples, requires less than 20 min per sample for fusion and separation. It was successfully coupled to inductively coupled plasma mass spectrometry (ICP-MS) achieving detection limits below 100 pg kg{sup -1} for 5-300 mg of sample.

  16. Sequential enzymatic derivatization coupled with online microdialysis sampling for simultaneous profiling of mouse tumor extracellular hydrogen peroxide, lactate, and glucose.

    Science.gov (United States)

    Su, Cheng-Kuan; Tseng, Po-Jen; Chiu, Hsien-Ting; Del Vall, Andrea; Huang, Yu-Fen; Sun, Yuh-Chang

    2017-03-01

    Probing tumor extracellular metabolites is a vitally important issue in current cancer biology. In this study an analytical system was constructed for the in vivo monitoring of mouse tumor extracellular hydrogen peroxide (H 2 O 2 ), lactate, and glucose by means of microdialysis (MD) sampling and fluorescence determination in conjunction with a smart sequential enzymatic derivatization scheme-involving a loading sequence of fluorogenic reagent/horseradish peroxidase, microdialysate, lactate oxidase, pyruvate, and glucose oxidase-for step-by-step determination of sampled H 2 O 2 , lactate, and glucose in mouse tumor microdialysate. After optimization of the overall experimental parameters, the system's detection limit reached as low as 0.002 mM for H 2 O 2 , 0.058 mM for lactate, and 0.055 mM for glucose, based on 3 μL of microdialysate, suggesting great potential for determining tumor extracellular concentrations of lactate and glucose. Spike analyses of offline-collected mouse tumor microdialysate and monitoring of the basal concentrations of mouse tumor extracellular H 2 O 2 , lactate, and glucose, as well as those after imparting metabolic disturbance through intra-tumor administration of a glucose solution through a prior-implanted cannula, were conducted to demonstrate the system's applicability. Our results evidently indicate that hyphenation of an MD sampling device with an optimized sequential enzymatic derivatization scheme and a fluorescence spectrometer can be used successfully for multi-analyte monitoring of tumor extracellular metabolites in living animals. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Time optimization of 90Sr measurements: Sequential measurement of multiple samples during ingrowth of 90Y

    International Nuclear Information System (INIS)

    Holmgren, Stina; Tovedal, Annika; Björnham, Oscar; Ramebäck, Henrik

    2016-01-01

    The aim of this paper is to contribute to a more rapid determination of a series of samples containing 90 Sr by making the Cherenkov measurement of the daughter nuclide 90 Y more time efficient. There are many instances when an optimization of the measurement method might be favorable, such as; situations requiring rapid results in order to make urgent decisions or, on the other hand, to maximize the throughput of samples in a limited available time span. In order to minimize the total analysis time, a mathematical model was developed which calculates the time of ingrowth as well as individual measurement times for n samples in a series. This work is focused on the measurement of 90 Y during ingrowth, after an initial chemical separation of strontium, in which it is assumed that no other radioactive strontium isotopes are present. By using a fixed minimum detectable activity (MDA) and iterating the measurement time for each consecutive sample the total analysis time will be less, compared to using the same measurement time for all samples. It was found that by optimization, the total analysis time for 10 samples can be decreased greatly, from 21 h to 6.5 h, when assuming a MDA of 1 Bq/L and at a background count rate of approximately 0.8 cpm. - Highlights: • An approach roughly a factor of three more efficient than an un-optimized method. • The optimization gives a more efficient use of instrument time. • The efficiency increase ranges from a factor of three to 10, for 10 to 40 samples.

  18. Multi-volatile method for aroma analysis using sequential dynamic headspace sampling with an application to brewed coffee.

    Science.gov (United States)

    Ochiai, Nobuo; Tsunokawa, Jun; Sasamoto, Kikuo; Hoffmann, Andreas

    2014-12-05

    A novel multi-volatile method (MVM) using sequential dynamic headspace (DHS) sampling for analysis of aroma compounds in aqueous sample was developed. The MVM consists of three different DHS method parameters sets including choice of the replaceable adsorbent trap. The first DHS sampling at 25 °C using a carbon-based adsorbent trap targets very volatile solutes with high vapor pressure (>20 kPa). The second DHS sampling at 25 °C using the same type of carbon-based adsorbent trap targets volatile solutes with moderate vapor pressure (1-20 kPa). The third DHS sampling using a Tenax TA trap at 80 °C targets solutes with low vapor pressure (0.9910) and high sensitivity (limit of detection: 1.0-7.5 ng mL(-1)) even with MS scan mode. The feasibility and benefit of the method was demonstrated with analysis of a wide variety of aroma compounds in brewed coffee. Ten potent aroma compounds from top-note to base-note (acetaldehyde, 2,3-butanedione, 4-ethyl guaiacol, furaneol, guaiacol, 3-methyl butanal, 2,3-pentanedione, 2,3,5-trimethyl pyrazine, vanillin, and 4-vinyl guaiacol) could be identified together with an additional 72 aroma compounds. Thirty compounds including 9 potent aroma compounds were quantified in the range of 74-4300 ng mL(-1) (RSD<10%, n=5). Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2009-01-01

    Full Text Available Background/Aim. Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Methods. Separation of the drug from matrix is achieved by reversedphase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1 at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10 using chlorophorm. Results. Calibration curves were in the range 0.1-5 μg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD of carbamazepine in serum and saliva were 0.166 and 0.178 μg/mL, respectively. Limits of quantification (LOQ in the serum and saliva were 0.237 and 0.226 μg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001. Conclusion. The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  20. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav

    2009-05-01

    Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  1. Efficient Sequential Monte Carlo Sampling for Continuous Monitoring of a Radiation Situation

    Czech Academy of Sciences Publication Activity Database

    Šmídl, Václav; Hofman, Radek

    2014-01-01

    Roč. 56, č. 4 (2014), s. 514-527 ISSN 0040-1706 R&D Projects: GA MV VG20102013018 Institutional support: RVO:67985556 Keywords : radiation protection * atmospheric dispersion model * importance sampling Subject RIV: BD - Theory of Information Impact factor: 1.814, year: 2014 http://library.utia.cas.cz/separaty/2014/AS/smidl-0433631.pdf

  2. Adaptive decision making in a dynamic environment: a test of a sequential sampling model of relative judgment.

    Science.gov (United States)

    Vuckovic, Anita; Kwantes, Peter J; Neal, Andrew

    2013-09-01

    Research has identified a wide range of factors that influence performance in relative judgment tasks. However, the findings from this research have been inconsistent. Studies have varied with respect to the identification of causal variables and the perceptual and decision-making mechanisms underlying performance. Drawing on the ecological rationality approach, we present a theory of the judgment and decision-making processes involved in a relative judgment task that explains how people judge a stimulus and adapt their decision process to accommodate their own uncertainty associated with those judgments. Undergraduate participants performed a simulated air traffic control conflict detection task. Across two experiments, we systematically manipulated variables known to affect performance. In the first experiment, we manipulated the relative distances of aircraft to a common destination while holding aircraft speeds constant. In a follow-up experiment, we introduced a direct manipulation of relative speed. We then fit a sequential sampling model to the data, and used the best fitting parameters to infer the decision-making processes responsible for performance. Findings were consistent with the theory that people adapt to their own uncertainty by adjusting their criterion and the amount of time they take to collect evidence in order to make a more accurate decision. From a practical perspective, the paper demonstrates that one can use a sequential sampling model to understand performance in a dynamic environment, allowing one to make sense of and interpret complex patterns of empirical findings that would otherwise be difficult to interpret using standard statistical analyses. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  3. Per- and polyfluoroalkyl substances in human serum and urine samples from a residentially exposed community.

    Science.gov (United States)

    Worley, Rachel Rogers; Moore, Susan McAfee; Tierney, Bruce C; Ye, Xiaoyun; Calafat, Antonia M; Campbell, Sean; Woudneh, Million B; Fisher, Jeffrey

    2017-09-01

    Per- and polyfluoroalkyl substances (PFAS) are considered chemicals of emerging concern, in part due to their environmental and biological persistence and the potential for widespread human exposure. In 2007, a PFAS manufacturer near Decatur, Alabama notified the United States Environmental Protection Agency (EPA) it had discharged PFAS into a wastewater treatment plant, resulting in environmental contamination and potential exposures to the local community. To characterize PFAS exposure over time, the Agency for Toxic Substances and Disease Registry (ATSDR) collected blood and urine samples from local residents. Eight PFAS were measured in serum in 2010 (n=153). Eleven PFAS were measured in serum, and five PFAS were measured in urine (n=45) from some of the same residents in 2016. Serum concentrations were compared to nationally representative data and change in serum concentration over time was evaluated. Biological half-lives were estimated for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS) using a one-compartment pharmacokinetic model. In 2010 and 2016, geometric mean PFOA and PFOS serum concentrations were elevated in participants compared to the general U.S. In 2016, the geometric mean PFHxS serum concentration was elevated compared to the general U.S. Geometric mean serum concentrations of PFOA, PFOS, and perfluorononanoic acid (PFNA) were significantly (p≤0.0001) lower (49%, 53%, and 58%, respectively) in 2016 compared to 2010. Half-lives for PFOA, PFOS, and PFHxS were estimated to be 3.9, 3.3, and 15.5years, respectively. Concentrations of PFOA in serum and urine were highly correlated (r=0.75) in males. Serum concentrations of some PFAS are decreasing in this residentially exposed community, but remain elevated compared to the U.S. general population. Published by Elsevier Ltd.

  4. Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples

    Directory of Open Access Journals (Sweden)

    Samira Moraes Cunha de Mesquita

    2015-06-01

    Full Text Available ABSTRACT. Mesquita S.M.C., Mansur F.J., Nascimento E.R., Barreto M.L. & Kimura L.M.S. [Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples.] Padroniza- ção e aplicação de ELISA indireto para diagnóstico de Mycoplasma bovis em amostras de soro sanguíneo bovino. Revista Brasileira de Medicina Veterinária, 37(2:101-107, 2015. Universidade Federal Fluminense, Faculdade de Veteriná- ria, Rua Vital Brazil Filho, 64, Vital Brazil, Niterói, RJ 24230-340, Brasil. E-mail: samira.veterinaria@gmail.com International researchers presented results indicating frequent involvement of Mycoplasma spp. as a causative agent of mastitis in cattle, associating its presence with significant economic losses to farmers. Mycoplasma bovis is the species most reported and relevant, because it causes more severe disease. The level of antibodies against M. bovis remains high for several months and can be detected by ELISA. The aim of this work was to develop an indirect ELISA with whole cell antigen of M. bovis (strain Donetta PG 45 with subsequent application in bovine blood serum samples for detection of antibodies against M. bovis. The immunization of cows A and B by inoculating an immunogen against M. bovis to obtain hyperimmune blood serum was the first stage of this work, then the stage of standardization of ELISA was proceeded. The concentration of 2 mg of antigen/mL for coating the microtiter plates was decided by statistical analyses. The optical density value 0,2 was determined as the limit of reactivity discrimination of samples (the cut-off point. The hyperimmune blood serum sample of the cow A (collected 30 days after immunization was chosen as the positive control and, the fetal calf serum was chosen as negative control of the assay. In addition, the ideal optimal dilutions found for blood serum samples was 1:400 and for conjugate was 1:10.000 and the substrate used was the ortho

  5. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review.

    Science.gov (United States)

    Thelin, Eric Peter; Zeiler, Frederick Adam; Ercole, Ari; Mondello, Stefania; Büki, András; Bellander, Bo-Michael; Helmy, Adel; Menon, David K; Nelson, David W

    2017-01-01

    The proteins S100B, neuron-specific enolase (NSE), glial fibrillary acidic protein (GFAP), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), and neurofilament light (NF-L) have been serially sampled in serum of patients suffering from traumatic brain injury (TBI) in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term "effective half-life" ( t 1/2 ) in order to describe the "fall" rate in serum. Through searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations. Following screening (10,389 papers), n  = 122 papers were included. The proteins S100B ( n  = 66) and NSE ( n  = 27) were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t 1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1-2 h) though possibly of non-cerebral origin. In contrast, the t 1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP ( n  = 18) appears to have t 1/2 of about 24-48 h in severe TBI. The protein UCH-L1 ( n  = 9) presents a t 1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L ( n  = 2) only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use. Serial sampling of brain-specific proteins in serum reveals different temporal trajectories that should be

  6. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Eric Peter Thelin

    2017-07-01

    Full Text Available BackgroundThe proteins S100B, neuron-specific enolase (NSE, glial fibrillary acidic protein (GFAP, ubiquitin carboxy-terminal hydrolase L1 (UCH-L1, and neurofilament light (NF-L have been serially sampled in serum of patients suffering from traumatic brain injury (TBI in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term “effective half-life” (t1/2 in order to describe the “fall” rate in serum.Materials and methodsThrough searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations.ResultsFollowing screening (10,389 papers, n = 122 papers were included. The proteins S100B (n = 66 and NSE (n = 27 were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1–2 h though possibly of non-cerebral origin. In contrast, the t1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP (n = 18 appears to have t1/2 of about 24–48 h in severe TBI. The protein UCH-L1 (n = 9 presents a t1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L (n = 2 only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use.ConclusionSerial sampling of brain-specific proteins in serum reveals

  7. Sequential determination of multi-nutrient elements in natural water samples with a reverse flow injection system.

    Science.gov (United States)

    Lin, Kunning; Ma, Jian; Yuan, Dongxing; Feng, Sichao; Su, Haitao; Huang, Yongming; Shangguan, Qipei

    2017-05-15

    An integrated system was developed for automatic and sequential determination of NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ in natural waters based on reverse flow injection analysis combined with spectrophotometric detection. The system operation was controlled by a single chip microcomputer and laboratory-programmed software written in LabVIEW. The experimental parameters for each nutrient element analysis were optimized based on a univariate experimental design, and interferences from common ions were evaluated. The upper limits of the linear range (along with detection limit, µmolL -1 ) of the proposed method was 20 (0.03), 200 (0.7), 12 (0.3), 5 (0.03), 5 (0.03), 9 (0.2) µmolL -1 , for NO 2 - , NO 3 - , PO 4 3- , Fe 2+ , Fe 3+ and Mn 2+ , respectively. The relative standard deviations were below 5% (n=9-13) and the recoveries varied from 88.0±1.0% to 104.5±1.0% for spiked water samples. The sample throughput was about 20h -1 . This system has been successfully applied for the determination of multi-nutrient elements in different kinds of water samples and showed good agreement with reference methods (slope 1.0260±0.0043, R 2 =0.9991, n=50). Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Predictors of Serum 25-Hydroxyvitamin D Concentrations among a Sample of Egyptian Schoolchildren

    Directory of Open Access Journals (Sweden)

    Mones M. Abu Shady

    2016-01-01

    Full Text Available Objective. To assess the level of 25-hydroxyvitamin D status among a sample of Egyptian schoolchildren and to evaluate predictors of deficiency and insufficiency. Subjects and Methods. A cross-sectional study comprising 200 prepubescent schoolchildren aged from 9 to 11 years was performed. A questionnaire including frequency of midday sun exposure, milk intake, physical activity, and level of maternal education was taken. Body mass index (BMI was calculated; serum 25-hydroxyvitamin D [25(OHD], serum calcium, phosphorus, and parathyroid hormone were measured. Results. Vitamin D deficiency [serum 25(OHD < 20 ng/mL] was detected in 11.5% of subjects while its insufficiency (serum 25(OHD is between 20 and 29.9 ng/mL was detected in 15%. Results revealed that obesity, low physical activity, low sun exposure, and low maternal education level are significant predictors of insufficiency, though female gender, low maternal education level, and low milk intake are significant predictors of deficiency. Lower serum phosphorus and higher serum parathyroid hormone were significantly associated with both deficiency and insufficiency (p<0.05. Conclusion. Vitamin D deficiency and insufficiency are common among schoolchildren in Egypt. Food fortification, vitamin D supplementation, and increasing maternal awareness about the importance of physical activity and exposure of their children to ultraviolet light may help to overcome this problem.

  9. Fixed-Precision Sequential Sampling Plans for Estimating Alfalfa Caterpillar, Colias lesbia, Egg Density in Alfalfa, Medicago sativa, Fields in Córdoba, Argentina

    Science.gov (United States)

    Serra, Gerardo V.; Porta, Norma C. La; Avalos, Susana; Mazzuferi, Vilma

    2013-01-01

    The alfalfa caterpillar, Colias lesbia (Fabricius) (Lepidoptera: Pieridae), is a major pest of alfalfa, Medicago sativa L. (Fabales: Fabaceae), crops in Argentina. Its management is based mainly on chemical control of larvae whenever the larvae exceed the action threshold. To develop and validate fixed-precision sequential sampling plans, an intensive sampling programme for C. lesbia eggs was carried out in two alfalfa plots located in the Province of Córdoba, Argentina, from 1999 to 2002. Using Resampling for Validation of Sampling Plans software, 12 additional independent data sets were used to validate the sequential sampling plan with precision levels of 0.10 and 0.25 (SE/mean), respectively. For a range of mean densities of 0.10 to 8.35 eggs/sample, an average sample size of only 27 and 26 sample units was required to achieve a desired precision level of 0.25 for the sampling plans of Green and Kuno, respectively. As the precision level was increased to 0.10, average sample size increased to 161 and 157 sample units for the sampling plans of Green and Kuno, respectively. We recommend using Green's sequential sampling plan because it is less sensitive to changes in egg density. These sampling plans are a valuable tool for researchers to study population dynamics and to evaluate integrated pest management strategies. PMID:23909840

  10. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling.

    Science.gov (United States)

    Aerts, Sam; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-10-01

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information-inside hotspots or in search of them-based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km2. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. Copyright © 2013 Elsevier Inc. All rights

  11. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling

    Energy Technology Data Exchange (ETDEWEB)

    Aerts, Sam, E-mail: sam.aerts@intec.ugent.be; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-10-15

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information—inside hotspots or in search of them—based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km{sup 2}. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2 dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. -- Highlights: • We present an

  12. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling

    International Nuclear Information System (INIS)

    Aerts, Sam; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-01-01

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information—inside hotspots or in search of them—based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km 2 . In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2 dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. -- Highlights: • We present an

  13. Sequential combined test, second trimester maternal serum markers, and circulating fetal cells to select women for invasive prenatal diagnosis.

    Directory of Open Access Journals (Sweden)

    Paolo Guanciali Franchi

    Full Text Available From January 1st 2013 to August 31st 2016, 24408 pregnant women received the first trimester Combined test and contingently offered second trimester maternal serum screening to identify those women who would most benefit from invasive prenatal diagnosis (IPD. The screening was based on first trimester cut-offs of ≥1:30 (IPD indicated, 1:31 to 1:899 (second trimester screening indicated and ≤1:900 (no further action, and a second trimester cut-off of ≥1:250. From January 2014, analysis of fetal cells from peripheral maternal blood was also offered to women with positive screening results. For fetal Down syndrome, the overall detection rate was 96.8% for a false-positive rate of 2.8% resulting in an odds of being affected given a positive result (OAPR of 1:11, equivalent to a positive predictive value (PPV of 8.1%. Additional chromosome abnormalities were also identified resulting in an OAPR for any chromosome abnormality of 1:6.6 (PPV 11.9%. For a sub-set of cases with positive contingent test results, FISH analysis of circulating fetal cells in maternal circulation identified 7 abnormal and 39 as normal cases with 100% specificity and 100% sensitivity. We conclude that contingent screening using conventional Combined and second trimester screening tests is effective but can potentially be considerably enhanced through the addition of fetal cell analysis.

  14. Quantitative profiling of serum samples using TMT protein labelling, fractionation and LC-MS/MS.

    Science.gov (United States)

    Sinclair, John; Timms, John F

    2011-08-01

    Blood-borne biomarkers are urgently required for the early detection, accurate diagnosis and prognosis of disease. Additionally, improved methods of profiling serum and plasma proteins for biomarker discovery efforts are needed. Herein, we report a quantitative method based on amino-group labelling of serum proteins (rather than peptides) with isobaric tandem mass tags (TMT) and incorporating immune-based depletion, gel-based and strong anion exchange separation of proteins prior to differential endoproteinase treatment and liquid chromatography tandem mass spectrometry. We report a generally higher level of quantitative coverage of the serum proteome compared to other peptide-based isobaric tagging approaches and show the potential of the method by applying it to a set of unique samples that pre-date the diagnosis of pancreatic cancer. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Analysis of human serum by liquid chromatography-mass spectrometry: improved sample preparation and data analysis.

    Science.gov (United States)

    Govorukhina, N I; Reijmers, T H; Nyangoma, S O; van der Zee, A G J; Jansen, R C; Bischoff, R

    2006-07-07

    Discovery of biomarkers is a fast developing field in proteomics research. Liquid chromatography coupled on line to mass spectrometry (LC-MS) has become a powerful method for the sensitive detection, quantification and identification of proteins and peptides in biological fluids like serum. However, the presence of highly abundant proteins often masks those of lower abundance and thus generally prevents their detection and identification in proteomics studies. To perform future comparative analyses of samples from a serum bank of cervical cancer patients in a longitudinal and cross-sectional manner, methodology based on the depletion of high-abundance proteins followed by tryptic digestion and LC-MS has been developed. Two sample preparation methods were tested in terms of their efficiency to deplete high-abundance serum proteins and how they affect the repeatability of the LC-MS data sets. The first method comprised depletion of human serum albumin (HSA) on a dye ligand chromatographic and immunoglobulin G (IgG) on an immobilized Protein A support followed by tryptic digestion, fractionation by cation-exchange chromatography, trapping on a C18 column and reversed-phase LC-MS. The second method included depletion of the six most abundant serum proteins based on multiple immunoaffinity chromatography followed by tryptic digestion, trapping on a C18 column and reversed-phase LC-MS. Repeatability of the overall procedures was evaluated in terms of retention time and peak area for a selected number of endogenous peptides showing that the second method, besides being less time consuming, gave more repeatable results (retention time: <0.1% RSD; peak area: <30% RSD). Application of an LC-MS component detection algorithm followed by principal component analysis (PCA) enabled discrimination of serum samples that were spiked with horse heart cytochrome C from non-spiked serum and the detection of a concentration trend, which correlated to the amount of spiked horse heart

  16. Serum chromium levels sampled with steel needle versus plastic IV cannula. Does method matter?

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Overgaard, Søren

    2010-01-01

    PURPOSE: Modern metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby...... causing bias. This study aimed to test that theory. METHODS: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. RESULTS: We found statistically significant chromium contamination from the steel needle...... with mean differences between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline...

  17. Serum Chrome levels sampled with steel needle vs. plastic IV cannula

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Overgaard, Søren

    2010-01-01

    . This study aimed to test that theory. Method: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. Results: We found statistically significant chromium contamination from the steel needle with mean differences......  Modern Metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby causing bias...... between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline significant...

  18. The effect of sequential dual-gas testing on laser-induced breakdown spectroscopy-based discrimination: Application to brass samples and bacterial strains

    International Nuclear Information System (INIS)

    Rehse, Steven J.; Mohaidat, Qassem I.

    2009-01-01

    Four Cu-Zn brass alloys with different stoichiometries and compositions have been analyzed by laser-induced breakdown spectroscopy (LIBS) using nanosecond laser pulses. The intensities of 15 emission lines of copper, zinc, lead, carbon, and aluminum (as well as the environmental contaminants sodium and calcium) were normalized and analyzed with a discriminant function analysis (DFA) to rapidly categorize the samples by alloy. The alloys were tested sequentially in two different noble gases (argon and helium) to enhance discrimination between them. When emission intensities from samples tested sequentially in both gases were combined to form a single 30-spectral line 'fingerprint' of the alloy, an overall 100% correct identification was achieved. This was a modest improvement over using emission intensities acquired in argon gas alone. A similar study was performed to demonstrate an enhanced discrimination between two strains of Escherichia coli (a Gram-negative bacterium) and a Gram-positive bacterium. When emission intensities from bacteria sequentially ablated in two different gas environments were combined, the DFA achieved a 100% categorization accuracy. This result showed the benefit of sequentially testing highly similar samples in two different ambient gases to enhance discrimination between the samples.

  19. Sequential extraction of heavy metals from urban dust and street sediments. Pt. 1. Sequential extraction of heavy metals in micro samples; Sequentielle Schwermetallextraktion aus Staubniederschlaegen und Strassensedimenten. T. 1. Sequentielle Schwermetallextraktion von Mikroproben

    Energy Technology Data Exchange (ETDEWEB)

    Heiser, U.; Norra, S.; Stueben, D.; Wagner, M. von [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Petrographie und Geochemie

    1999-01-01

    For the application of sequential extraction of heavy metals from samples that can only be obtained in amounts of a few milligrams (micro samples, e.g. airborne dust fallout), the method after Zeien and Bruemmer (1989) was progressed. A down scale to 1:100 was carried out and the accuracy of this method with variable sample amounts of about 20 mg and an extraction volume of 500 {mu}l was proofed with standard soil samples. The influence of variable extraction ratios (ratio of sample amount and volume of extraction solvent) and the influence of intensive treatment of dust sampled by the Bergerhoff-method (VDI 2119/2, 1972) prior sequential extraction, was within the precision of measurement of our method. Thus, we showed that sequential extraction can be applied for the investigation of heavy metal mobilization in micro samples with variable sample amounts. A first application of our method for microsamples was carried out to investigate airborne dust fallout and street sediments at two urban sites where different heavy metal immission rates due to traffic influence occur. These investigations will be presented in part 2 (`Sequential extraxction of heavy metals from urban dust`). (orig.) [Deutsch] Fuer die Anwendung der sequentiellen Schwermetallextraktion auf Proben, die nur im Milligramm-Bereich erhalten werden koennen (Mikroproben, wie z.B. Staubniederschlaege), wurde die Methode von Zeien und Bruemmer (1989) weiterentwickelt. Der Extraktionsmassstab wurde um den Faktor 1:100 verringert und die Reproduzierbarkeit des Verfahrens mit variablen Probenmengen um 20 mg und einem Extraktionsvolumen von 500 {mu}l mit Hilfe von Standardboeden nachgewiesen. Moegliche Einfluesse variabler Extraktionsverhaeltnisse (Verhaeltnis von Probenmenge zu Extraktionsvolumen) sowie eine aufwendige Vorbehandlung von Staubproben, die nach der Bergerhoff-Methode (VDI 2119/2, 1972) gesammelt wurden, lagen bei diesen Untersuchungen weitgehend im Variationsbereich des Verfahrens. Die

  20. Evaluation of Sample Handling Effects on Serum Vitamin E and Cholesterol Concentrations in Alpacas

    Directory of Open Access Journals (Sweden)

    Andrea S. Lear

    2014-01-01

    Full Text Available Clinical cases of vitamin E deficiencies have been diagnosed in camelids and may indicate that these species are more sensitive to inadequate vitamin E in hay-based diets compared to other ruminant and equine species. In bovine, cholesterol has been reported to affect vitamin E concentrations. In order to evaluate vitamin E deficiencies in camelids, the effects of collection and storage of the blood samples prior to processing were necessary. Reports vary as to factors affecting vitamin E and cholesterol in blood samples, and diagnostic laboratories vary in instructions regarding sample handling. Blood was collected from healthy alpacas and processed under conditions including exposure to fluorescent light, serum and red blood cell contact, tube stopper contact, temperature, and hemolysis. Serum vitamin E and cholesterol concentrations were then measured. Statistical analyses found that the vitamin E concentrations decreased with prolonged contact with the tube stopper and with increasing hemolysis. Vitamin E concentration variations were seen with other factors but were not significant. Time prior to serum separation and individual animal variation was found to alter cholesterol concentrations within the sample, yet this finding was clinically unremarkable. No correlation was seen between vitamin E and cholesterol concentration, possibly due to lack of variation of cholesterol.

  1. Quality assesment for the analysis of PCDDs/PCDFs in individual human serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Perez, F [IIQAB-CSIC, Barcelona (Spain). Dept. of Ecotechnologies, Lab. of Dioxins; Abad, E; Llerena, J J; Caixach, J; Rivera, J

    2004-09-15

    The aim of this work was to optimise a relevant methodology for the ultratrace analysis of PCDDs/PCDFs in individual human serum samples. In order to carry out the study, different strategies including the elaboration of quality control samples, parallel sample analysis, control blanks and a number of quality assurance measures were implemented as analytical current practices. Some of the main drawbacks in the analysis of PCDDs/PCDFs in these kind of samples come from two conflicting aspects: the small sample size and the low levels expected to be found. Taking this into account, an unavoidable compromise between the sample amount and the minimum analytical requirements, mainly the detection limit (LOD), is mandatory. To reach this goal C{sub 18} solid phase extraction was used to remove the analytes from the matrix. Clean up was performed by solid-liquid adsorption chromatography using a variety of adsorbents. Instrumental analysis was achieved by high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC/HRMS). Finally, the optimised methodology was applied to evaluate the potential impact in general population living in the surroundings of an obsolete municipal waste incinerator plant (MWI). Thus, more than 400 individuals serum samples potentially exposed to the emission of the incinerator and people not exposed were considered in this study.

  2. Effects of model complexity and priors on estimation using sequential importance sampling/resampling for species conservation

    Science.gov (United States)

    Dunham, Kylee; Grand, James B.

    2016-01-01

    We examined the effects of complexity and priors on the accuracy of models used to estimate ecological and observational processes, and to make predictions regarding population size and structure. State-space models are useful for estimating complex, unobservable population processes and making predictions about future populations based on limited data. To better understand the utility of state space models in evaluating population dynamics, we used them in a Bayesian framework and compared the accuracy of models with differing complexity, with and without informative priors using sequential importance sampling/resampling (SISR). Count data were simulated for 25 years using known parameters and observation process for each model. We used kernel smoothing to reduce the effect of particle depletion, which is common when estimating both states and parameters with SISR. Models using informative priors estimated parameter values and population size with greater accuracy than their non-informative counterparts. While the estimates of population size and trend did not suffer greatly in models using non-informative priors, the algorithm was unable to accurately estimate demographic parameters. This model framework provides reasonable estimates of population size when little to no information is available; however, when information on some vital rates is available, SISR can be used to obtain more precise estimates of population size and process. Incorporating model complexity such as that required by structured populations with stage-specific vital rates affects precision and accuracy when estimating latent population variables and predicting population dynamics. These results are important to consider when designing monitoring programs and conservation efforts requiring management of specific population segments.

  3. Retrospective analysis of dengue specific IgM reactive serum samples

    OpenAIRE

    Nemai Bhattacharya; Bhaswati Bandyopadhyay; Indranil Bhattacharjee; Hiranmoy Mukherjee; Srabani Talukdar; Ruby Mondal; Netai Pramanick; Goutam Chandra; Amiya K. Hati

    2013-01-01

    Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1) antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: Th...

  4. An attempt to validate serum and plasma as sample matrices for analyses of polychlorobiphenylols

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, J.; Bergman, Aa. [Stockholm Univ. (Sweden). Dept. of Environmental Chemistry; Bignert, A. [Museum of Natural History (Sweden)

    2004-09-15

    Polychlorinated biphenyls (PCBs) form hydroxylated metabolites (OH-PCBs), as reported both from wildlife and from experimental animal studies already in the early 1970s'. However, the interest increased in OH-PCBs from the mid 1990s' depending on the discovery that some OHPCB congeners are strongly retained in the blood of birds, fish and mammals, including humans. The interest is linked to the fact that OH-PCBs is strongly, but reversibly, bound to the blood protein transthyretin (TTR). It is reasonable to believe that the strong TTR binding may have toxicological impact, probably related to endocrine type effects. Importantly, OH-PCBs are present in blood at far higher concentrations than in any other compartment in the body, which is dependent on the physico-chemical characteristics of the phenols. Analyses of OH-PCBs have thus been concentrated to whole blood, plasma or serum. Still there is no comparison between the three sample types even though it is clear that whole blood is not optimal due to the large proportion of haemoglobin in the sample that make the clean up more difficult than if plasma or serum is selected for analysis. In the present study we have addressed two questions: First we have looked at any potential differences in the analytical results of OH-PCBs when using serum and plasma for extraction and clean up; Second, the serum and plasma applied in the validation has been unfrozen, frozen (at -20 C) for two months and frozen for twenty months, respectively.

  5. Implementing reduced-risk integrated pest management in fresh-market cabbage: influence of sampling parameters, and validation of binomial sequential sampling plans for the cabbage looper (Lepidoptera Noctuidae).

    Science.gov (United States)

    Burkness, Eric C; Hutchison, W D

    2009-10-01

    Populations of cabbage looper, Trichoplusiani (Lepidoptera: Noctuidae), were sampled in experimental plots and commercial fields of cabbage (Brasicca spp.) in Minnesota during 1998-1999 as part of a larger effort to implement an integrated pest management program. Using a resampling approach and the Wald's sequential probability ratio test, sampling plans with different sampling parameters were evaluated using independent presence/absence and enumerative data. Evaluations and comparisons of the different sampling plans were made based on the operating characteristic and average sample number functions generated for each plan and through the use of a decision probability matrix. Values for upper and lower decision boundaries, sequential error rates (alpha, beta), and tally threshold were modified to determine parameter influence on the operating characteristic and average sample number functions. The following parameters resulted in the most desirable operating characteristic and average sample number functions; action threshold of 0.1 proportion of plants infested, tally threshold of 1, alpha = beta = 0.1, upper boundary of 0.15, lower boundary of 0.05, and resampling with replacement. We found that sampling parameters can be modified and evaluated using resampling software to achieve desirable operating characteristic and average sample number functions. Moreover, management of T. ni by using binomial sequential sampling should provide a good balance between cost and reliability by minimizing sample size and maintaining a high level of correct decisions (>95%) to treat or not treat.

  6. Specific Antibodies Reacting with SV40 Large T Antigen Mimotopes in Serum Samples of Healthy Subjects.

    Directory of Open Access Journals (Sweden)

    Mauro Tognon

    Full Text Available Simian Virus 40, experimentally assayed in vitro in different animal and human cells and in vivo in rodents, was classified as a small DNA tumor virus. In previous studies, many groups identified Simian Virus 40 sequences in healthy individuals and cancer patients using PCR techniques, whereas others failed to detect the viral sequences in human specimens. These conflicting results prompted us to develop a novel indirect ELISA with synthetic peptides, mimicking Simian Virus 40 capsid viral protein antigens, named mimotopes. This immunologic assay allowed us to investigate the presence of serum antibodies against Simian Virus 40 and to verify whether Simian Virus 40 is circulating in humans. In this investigation two mimotopes from Simian Virus 40 large T antigen, the viral replication protein and oncoprotein, were employed to analyze for specific reactions to human sera antibodies. This indirect ELISA with synthetic peptides from Simian Virus 40 large T antigen was used to assay a new collection of serum samples from healthy subjects. This novel assay revealed that serum antibodies against Simian Virus 40 large T antigen mimotopes are detectable, at low titer, in healthy subjects aged from 18-65 years old. The overall prevalence of reactivity with the two Simian Virus 40 large T antigen peptides was 20%. This new ELISA with two mimotopes of the early viral regions is able to detect in a specific manner Simian Virus 40 large T antigen-antibody responses.

  7. Quantitation of 14C-oxaliplatin concentrations in human serum samples by using accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kobayashi, Takeshi; Toyoguchi, Teiko; Kato, Kazuhiro; Tokanai, Fuyuki; Shiraishi, Tadashi

    2013-01-01

    The understanding of human pharmacokinetics is important for development of new drugs. Microdosing studies have been proposed as means of obtaining human pharmacokinetics information at early stages of drug development. Accelerator mass spectrometry (AMS) has high detection sensitivity and is expected to play an important role in microdose trials. In this study, we used the AMS microdosing facility at Yamagata University to measure the concentration of 14 C in 14 C-oxaliplatin-spiked serum samples. The calibration curve of 14 C concentration in serum was linear, and the correlation coefficient was 0.9994. The precision, accuracy, and stability values obtained (freeze and thaw cycles, and short- and long-term stability) satisfied the criteria. The mean background 14 C concentrations in samples of 6 healthy Japanese volunteers were 1.635dpm/mL in blood and 0.56dpm/mL in plasma. These results suggest the suitability of AMS-based quantitation for analyzing samples from microdosing studies. (author)

  8. Fractionation of metals in street sediment samples by using the BCR sequential extraction procedure and multivariate statistical elucidation of the data

    International Nuclear Information System (INIS)

    Kartal, Senol; Aydin, Zeki; Tokalioglu, Serife

    2006-01-01

    The concentrations of metals (Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, and Zn) in street sediment samples were determined by flame atomic absorption spectrometry (FAAS) using the modified BCR (the European Community Bureau of Reference) sequential extraction procedure. According to the BCR protocol for extracting the metals from the relevant target phases, 1.0 g of specimen of the sample was treated with 0.11 M acetic acid (exchangeable and bound to carbonates), 0.5 M hydroxylamine hydrochloride (bound to iron- and manganese-oxides), and 8.8 M hydrogen peroxide plus 1 M ammonium acetate (bound to sulphides and organics), sequentially. The residue was treated with aqua regia solution for recovery studies, although this step is not part of the BCR procedure. The mobility sequence based on the sum of the BCR sequential extraction stages was: Cd ∼ Zn (∼90%) > Pb (∼84%) > Cu (∼75%) > Mn (∼70%) > Co (∼57%) > Ni (∼43%) > Cr (∼40%) > Fe (∼17%). Enrichment factors as the criteria for examining the impact of the anthropogenic emission sources of heavy metals were calculated, and it was observed that the highest enriched elements were Cd, Pb, and Zn in the dust samples, average 190, 111, and 20, respectively. Correlation analysis (CA) and principal component analysis (PCA) were applied to the data matrix to evaluate the analytical results and to identify the possible pollution sources of metals. PCA revealed that the sampling area was mainly influenced from three pollution sources, namely; traffic, industrial, and natural sources. The results show that chemical sequential extraction is a precious operational tool. Validation of the analytical results was checked by both recovery studies and analysis of the standard reference material (NIST SRM 2711 Montana Soil)

  9. Wet sample digestion for quantification of vanadium(V) in serum by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Heinemann, G.; Vogt, W.; Jacob, K.

    1999-01-01

    Three types of pressure digestion systems used prior to the determination of the ultratrace element vanadium by electrothermal atomic absorption spectrometry were evaluated: The high-pressure ashing (HPA) system, the DAB III pressure digestion system and the pressurized microwave digestion (PMD) system. Complete sample digestion and no loss of graphite tube sensitivity as well as reliable vanadium values could only be achieved with HPA digests of freeze-dried serum. The mean recovery rate was 98% and no loss of tube sensitivity could be observed. Using non-lyophilized serum the mean recovery rate was 70%. The DAB III digestion system, vicarious for closed pressure digestion in steel bombs with an allowable temperature up to about 200C, cannot be recommended to mineralize human biological material for vanadium determinations, because the remaining not completely decomposed organic compounds extracted together with the vanadium-cupferron complex caused a marked carbon-buildup and formation of carbides in the graphite tube were found to change the shape of the absorption signals distinctly, and to decline the tube sensitivity strongly (about 25%) so that reliable results cannot be achieved. The recovery rate was too low in general (about 50%). In addition, a subsequent treatment of the DAB III digests with perchloric acid was unsuccessful. The PMD system proved to be not suited, because the samples became highly contaminated by vanadium possibly from the titan seal. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  10. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    Science.gov (United States)

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  11. Comparison of parasite loads in serum and blood samples from patients in acute and chronic phases of Chagas disease.

    Science.gov (United States)

    Hernández, Carolina; Teherán, Aníbal; Flórez, Carolina; Ramírez, Juan David

    2018-04-17

    Molecular methods have been developed for the detection and quantification of Trypanosoma cruzi DNA in blood samples from patients with Chagas disease. However, aspects of sample processing necessary for quantitative real-time PCR (qPCR), such as the addition of guanidine hydrochloride to whole blood samples, may limit timely access to molecular diagnosis. We analysed 169 samples from serum and guanidine-EDTA blood (GEB) obtained from patients in acute and chronic phases of Chagas disease. We applied qPCR targeted to the satellite DNA region. Finally, we compared the parasite loads and cycle of threshold values of the qPCR. The results confirmed the usefulness of serum samples for the detection and quantification of parasite DNA in patients with Chagas disease, especially in the acute phase. However, the parasite loads detected in serum samples from patients in the chronic phase were lower than those detected in GEB samples. The epidemiological implications of the findings are herein discussed.

  12. Slurry sampling in serum blood for mercury determination by CV-AFS

    International Nuclear Information System (INIS)

    Aranda, Pedro R.; Gil, Raul A.; Moyano, Susana; De Vito, Irma; Martinez, Luis D.

    2009-01-01

    The heavy metal mercury (Hg) is a neurotoxin known to have a serious health impact even at relatively low concentrations. A slurry method was developed for the sensitive and precise determination of mercury in human serum blood samples by cold vapor generation coupled to atomic fluorescence spectrometry (CV-AFS). All variables related to the slurry formation were studied. The optimal hydrochloric concentration and tin(II) chloride concentration for CV generation were evaluated. Calibration within the range 0.1-10 μg L -1 Hg was performed with the standard addition method, and compared with an external calibration. Additionally, the reliability of the results obtained was evaluated by analyzing mercury in the same samples, but submitted to microwave-assisted digestion method. The limit of detection was calculated as 25 ng L -1 and the relative standard deviation was 3.9% at levels around of 0.4 μg L -1 Hg

  13. A Novel Genetic Group of Bovine Hepacivirus in Archival Serum Samples from Brazilian Cattle

    Directory of Open Access Journals (Sweden)

    Cláudio W. Canal

    2017-01-01

    Full Text Available Hepatitis C virus (HCV (genus Hepacivirus; family Flaviviridae is a major human pathogen causing persistent infection and hepatic injury. Recently, emerging HCV-like viruses were described infecting wild animals, such as bats and rodents, and domestic animals, including dogs, horses, and cattle. Using degenerate primers for detecting bovine pestiviruses in a 1996 survey three bovine serum samples showed a low identity with the genus Pestivirus of the Flaviviridae family. A virus could not be isolated in cell culture. The description of bovine hepaciviruses (BovHepV in 2015 allowed us to retrospectively identify the sequences as BovHepV, with a 88.9% nucleotide identity. In a reconstructed phylogenetic tree, the Brazilian BovHepV samples grouped within the bovine HCV-like cluster in a separated terminal node that was more closely related to the putative bovine Hepacivirus common ancestor than to bovine hepaciviruses detected in Europe and Africa.

  14. Study of Zn/Cu ratio and oligoelements in serum samples for cancer diagnosis

    International Nuclear Information System (INIS)

    Lue-Meru, M. P.; Jimenez, E.; Hernandez, E.; Rojas, A.; Greaves, E.

    2000-01-01

    The aim of this work was to study methods for cancer diagnosis based on trace element determination in serum blood samples. TXRF technique was selected for the analysis, due to its simultaneous and multi-elemental character, the very small amount of sample required and the high sensitivity. For the study, blood samples were collected from normal individuals (Blood donors and students), classified by age and sex in order to obtain reference normal values for the elements Zn, Cu, Fe, Mn, Se, and additionally, Ca and K. Samples from cancer patients before treatment and under treatment were collected at the oncological Service (BADAN-Lara), and were also classified by age and sex. The TXRF procedure used was developed in a previous work and involves the direct analysis and the use of Compton peak as Internal Standard. All the samples were analyzed by the routine clinical test (blood chemistry). Elemental concentrations and clinical data were processed with the statistical package Minitab-Windows, in order to establish the respective correlation. Concerning to elemental concentrations, significant differences were found in Zn/Cu ratio between normal individuals group and the cancer patients group. (author)

  15. Development of a sequential injection-square wave voltammetry method for determination of paraquat in water samples employing the hanging mercury drop electrode.

    Science.gov (United States)

    dos Santos, Luciana B O; Infante, Carlos M C; Masini, Jorge C

    2010-03-01

    This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 µL s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), µA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): i(p) = (-20.5 ± 0.3)C (paraquat) - (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 µg L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.

  16. Serum thromboxane B2 (TXB2 Determination is Influenced by Sample Incubation Temperature in Healthy Beagle Dogs

    Directory of Open Access Journals (Sweden)

    Aleš Jerin

    2009-01-01

    Full Text Available The measurement of serum thromboxane B2 (TXB2 production by platelets is a specific test for assessment of platelet cyclooxygenase (COX-1 activity following administration of non-steroidal anti-inflammatory drugs (NSAIDs. The aim of this study was to investigate the influence of sample incubation at 37 °C for one hour on serum TXB2 concentration in comparison with incubation at room temperature. A total of 54 blood samples for serum TXB2 measurements were collected from six healthy beagle dogs into two separate serum tubes. While one group of tubes was incubated in a 37 °C water bath, the second group of tubes was left to coagulate at room temperature, both for one hour. Serum TXB2 concentrations were measured by ELISA. The mean concentration (± SD of serum TXB2 in the group of samples that were incubated at 37 °C was significantly (P 2 concentration in healthy beagle dogs and demonstrate that validated methods for assessment of COX-1 activity by measurement of serum TXB2 should be used in order to make results more reliable and comparable between different studies. The results of this study might be of great help in planning NSAID studies in dogs by providing the information that TXB2 generation by platelets is influenced profoundly by incubation temperature.

  17. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  18. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  19. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays. Laboratory strategies to detect interference

    Directory of Open Access Journals (Sweden)

    Elena García-González

    2016-04-01

    Full Text Available Objectives: Endogenous antibodies (EA may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Subjects and methods: Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Results: Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house ‘nonsense’ sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Conclusions: Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern. Keywords: Endogenous antibodies, Immunoassay, Interference, Pituitary hormones, Case report

  20. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  1. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Casey, Cameron P. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Stratton, Kelly G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zink, Erika M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Kim, Young-Mo [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zheng, Xueyun [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Monroe, Matthew E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Weitz, Karl K. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Bloodsworth, Kent J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Orton, Daniel J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Ibrahim, Yehia M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Moore, Ronald J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Lee, Christine G. [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Research Service, Portland Veterans Affairs Medical Center, Portland OR USA; Pedersen, Catherine [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Orwoll, Eric [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Smith, Richard D. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Burnum-Johnson, Kristin E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Baker, Erin S. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2017-02-05

    The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

  2. Fast sequential multi-element determination of major and minor elements in environmental samples and drinking waters by high-resolution continuum source flame atomic absorption spectrometry.

    Science.gov (United States)

    Gómez-Nieto, Beatriz; Gismera, Ma Jesús; Sevilla, Ma Teresa; Procopio, Jesús R

    2015-01-07

    The fast sequential multi-element determination of 11 elements present at different concentration levels in environmental samples and drinking waters has been investigated using high-resolution continuum source flame atomic absorption spectrometry. The main lines for Cu (324.754 nm), Zn (213.857 nm), Cd (228.802 nm), Ni (232.003 nm) and Pb (217.001 nm), main and secondary absorption lines for Mn (279.482 and 279.827 nm), Fe (248.327, 248.514 and 302.064 nm) and Ca (422.673 and 239.856 nm), secondary lines with different sensitivities for Na (589.592 and 330.237 nm) and K (769.897 and 404.414 nm) and a secondary line for Mg (202.582 nm) have been chosen to perform the analysis. A flow injection system has been used for sample introduction so sample consumption has been reduced up to less than 1 mL per element, measured in triplicate. Furthermore, the use of multiplets for Fe and the side pixel registration approach for Mg have been studied in order to reduce sensitivity and extend the linear working range. The figures of merit have been calculated and the proposed method was applied to determine these elements in a pine needles reference material (SRM 1575a), drinking and natural waters and soil extracts. Recoveries of analytes added at different concentration levels to water samples and extracts of soils were within 88-115% interval. In this way, the fast sequential multi-element determination of major and minor elements can be carried out, in triplicate, with successful results without requiring additional dilutions of samples or several different strategies for sample preparation using about 8-9 mL of sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Effects of coagulation temperature on measurements of complement function in serum samples from patients with systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Baatrup, G; Sturfelt, G; Junker, A

    1992-01-01

    Blood samples from 15 patients with systemic lupus erythematosus (SLE) and 15 healthy blood donors were allowed to coagulate for one hour at room temperature, followed by one hour at 4 or 37 degrees C. The complement activity of the serum samples was assessed by three different functional assays...

  4. Usefulness of in-house real time PCR for HBV DNA quantification in serum and oral fluid samples.

    Science.gov (United States)

    Portilho, Moyra Machado; Mendonça, Ana Carolina da Fonseca; Bezerra, Cristianne Sousa; do Espirito-Santo, Márcia Paschoal; de Paula, Vanessa Salete; Nabuco, Leticia Cancella; Villela-Nogueira, Cristiane Alves; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2018-06-01

    For quantification of hepatitis B virus DNA (HBV DNA), commercial assays are used with serum or plasma samples, but oral fluid samples could be an alternative for HBV diagnosis due to ease of collection. This study aims to develop in-house real time PCR using synthetic curve for HBV DNA quantification for serum and oral fluid samples. Samples were collected from 103 individuals (55 HBsAg reactive and HBV DNA reactive by commercial assay and 48 without HBV markers) and submitted to two in-house real time PCR assays for HBV pre-S/S region with different standard curves: qPCR plasmidial and qPCR synthetic. A total of 27 serum samples were HBV DNA positive by qPCR plasmidial and 40 with qPCR synthetic (72% and 85% of concordance, respectively). Quantitative PCR synthetic presented efficiency of 99% and sensitivity of 2log10 copies/mL. Among oral fluid samples, five and ten were detected using qPCR plasmidial and synthetic, respectively. This study demonstrated that qPCR synthetic using serum samples could be used as alternative for HBV DNA quantification due to its sensitivity. In addition, it was possible to quantify HBV DNA in oral fluid samples suggesting the potential of this specimen for molecular diagnosis of HBV. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2014-01-01

    Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.

  6. Rapid and simultaneous determination of neptunium and plutonium isotopes in environmental samples by extraction chromatography using sequential injection analysis and ICP-MS

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2010-01-01

    plutonium and neptunium in three reference materials were in agreement with the recommended or literature values at the 0.05 significance level. The developed method is suitable for the analysis of up to 10 g of soil and 20 g of seaweed samples. The extraction chromatographic separation within the SI system......This paper reports an automated analytical method for rapid and simultaneous determination of plutonium isotopes (239Pu and 240Pu) and neptunium (237Np) in environmental samples. An extraction chromatographic column packed with TrisKem TEVA® resin was incorporated in a sequential injection (SI...... for a single sample takes less than 1.5 h. As compared to batchwise procedures, the developed method significantly improves the analysis efficiency, reduces the labor intensity and expedites the simultaneous determination of plutonium and neptunium as demanded in emergency actions....

  7. Retrospective analysis of dengue specific IgM reactive serum samples

    Directory of Open Access Journals (Sweden)

    Nemai Bhattacharya

    2013-04-01

    Full Text Available Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1 antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: This reconstructed study revealed that of those 91 dengue cases, 70.3% (64 and 29.7% (27 were suffering from secondary and primary dengue respectively, showing that number of secondary dengue cases were much more than that of primary dengue cases with a possibility of emergence of DHF. A small proportion of cases 18.7% (17 were reactive for NS1. The duration of fever in NS1 antigen positive cases varied between 5 and 7 days. Of 17 NS1 reactive cases, 10 (10.9% and 7 (7.7% were suffering from secondary and primary dengue respectively. Conclusions: Early detection of primary and secondary dengue cases would be facilitated by utilizing all three parameters (NS1 antigen, anti-dengue IgM and IgG helping to evaluate, monitor and treat a dengue case effectively.

  8. Serum cadmium levels in a sample of blood donors in the Western Amazon, Brazil, 2010-2011

    Directory of Open Access Journals (Sweden)

    Andre Ricardo Maia da Costa de Faro

    2014-02-01

    Full Text Available A cross-sectional study was conducted to determine the distribution of serum cadmium (Cd levels in blood donors in Rio Branco, Acre State, Brazil. Blood samples were obtained from 922 volunteer blood donors from 18 to 65 years of age at the Hemoacre blood center in 2010-2011. Mean serum Cd was 0.37µg/L (95%CI: 0.33-0.41. Increased serum Cd was associated with lower schooling; individuals with less than five years of schooling showed a mean Cd of 0.61µg/L (95%CI: 0.34-0.89, compared to 0.34µg/L (95%CI: 0.28-0.40 among those with more than nine years of schooling. Mean serum Cd was three times higher among smokers. Smoking showed a positive association with Cd level, with an OR of 12.36 (95%CI: 7.70-19.84. Meanwhile, serum Cd was lower among individuals that regularly drank tea, as compared to non-tea drinkers. Serum Cd levels were mostly below the reference value (88.3% of participants. Mean serum Cd in the current study indicates that in general the population studied here is not exposed to worrisome Cd levels.

  9. Stability of BDNF in Human Samples Stored Up to 6 Months and Correlations of Serum and EDTA-Plasma Concentrations.

    Science.gov (United States)

    Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L

    2017-06-03

    Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.

  10. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

    Science.gov (United States)

    Böckel-Frohnhöfer, Nicole; Hübner, Ulrich; Hummel, Björn; Geisel, Jürgen

    2014-10-01

    Pneumatic tube systems are widely used in hospitals. Advantages are high speed and rapid availability of the samples. However, the transportation by pneumatic tube promotes haemolysis. Haemolysis interferes with many spectrophotometric assays and is a common problem in clinical laboratories. The haemolysis index (HI) as a semi-quantitative representation of the level of haemolysis was compared in unpaired tube-transported and hand-delivered routine lithium heparinate plasma samples (n = 1368 and n = 837, respectively). Additionally, the HI distribution was measured in lithium heparinate plasma samples with a HI above the threshold value of 20 and in paired serum samples after transportation by pneumatic tube system. HI values above 20 can interfere with the selected assays: Creatine kinase (CK), creatine kinase-MB (CK-MB) and alanine aminotransferase (ALT) activities. These parameters were determined to demonstrate how haemolysis affects the results. 17.5% of the tube-transported plasma samples and 2.6% of the hand-delivered plasma samples had a HI above 20. The median HI in pneumatic tube-transported lithium heparinate plasma was 85 and 33 in the paired serum samples. The median HI difference between paired plasma and serum was 46. Blood samples in lithium heparinate tubes may be substantially more susceptible to haemolysis by pneumatic tube transportation than serum tube samples. Although our results cannot be universally applied to laboratories with different pneumatic tube systems, it is recommended that each laboratory evaluate carefully the degree of haemolysis after the transportation by the own pneumatic tube system and in terms of the sample type.

  11. Rapid Determination of Plutonium Isotopes in Environmental Samples Using Sequential Injection Extraction Chromatography and Detection by Inductively Coupled Plasma Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2009-01-01

    This article presents an automated method for the rapid determination of 239Pu and 240Pu in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed...... by detection of isolated analytes with inductively coupled plasma mass spectrometry (ICP-MS). The method has been devised for the determination of Pu isotopes at environmentally relevant concentrations, whereby it has been successfully applied to the analyses of large volumes/amounts of samples, for example......, 100−200 g of soil and sediment, 20 g of seaweed, and 200 L of seawater following analyte preconcentration. The investigation of the separation capability of the assembled SI system revealed that up to 200 g of soil or sediment can be treated using a column containing about 0.70 g of TEVA resin...

  12. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab...

  13. Evaluation of HER2/neu oncoprotein in serum & tissue samples of women with breast cancer

    Directory of Open Access Journals (Sweden)

    Shailaja Shukla

    2016-01-01

    Interpretation & conclusions: The results suggest that elevated serum HER2 level was associated with a clinicopathological aggressive phenotype of breast carcinoma and was related to tissue HER2 overexpression. Therefore, serum HER2 may be useful for monitoring the course of the disease and response to treatment.

  14. A computational platform for MALDI-TOF mass spectrometry data: application to serum and plasma samples.

    Science.gov (United States)

    Mantini, Dante; Petrucci, Francesca; Pieragostino, Damiana; Del Boccio, Piero; Sacchetta, Paolo; Candiano, Giovanni; Ghiggeri, Gian Marco; Lugaresi, Alessandra; Federici, Giorgio; Di Ilio, Carmine; Urbani, Andrea

    2010-01-03

    Mass spectrometry (MS) is becoming the gold standard for biomarker discovery. Several MS-based bioinformatics methods have been proposed for this application, but the divergence of the findings by different research groups on the same MS data suggests that the definition of a reliable method has not been achieved yet. In this work, we propose an integrated software platform, MASCAP, intended for comparative biomarker detection from MALDI-TOF MS data. MASCAP integrates denoising and feature extraction algorithms, which have already shown to provide consistent peaks across mass spectra; furthermore, it relies on statistical analysis and graphical tools to compare the results between groups. The effectiveness in mass spectrum processing is demonstrated using MALDI-TOF data, as well as SELDI-TOF data. The usefulness in detecting potential protein biomarkers is shown comparing MALDI-TOF mass spectra collected from serum and plasma samples belonging to the same clinical population. The analysis approach implemented in MASCAP may simplify biomarker detection, by assisting the recognition of proteomic expression signatures of the disease. A MATLAB implementation of the software and the data used for its validation are available at http://www.unich.it/proteomica/bioinf. (c) 2009 Elsevier B.V. All rights reserved.

  15. Determination of human albumin in serum and urine samples by constant-energy synchronous fluorescence method.

    Science.gov (United States)

    Madrakian, Tayyebeh; Bagheri, Habibollah; Afkhami, Abbas

    2015-08-01

    A sensitive spectrofluorimetric method using constant-energy synchronous fluorescence technique is proposed for the determination of human albumin without separation. In this method, no reagent was used for enhancement of the fluorescence signal of albumin in the solution. Effects of some parameters, such as energy difference between excitation and emission monochromators (ΔE), emission and excitation slit widths and scan rate of wavelength were studied and the optimum conditions were established. For this purpose factorial design and response surface method were employed for optimization of the effective parameters on the fluorescence signal. The results showed that the scan rate of the wavelength has no significant effect on the analytical signal. The calibration curve was linear in the range 0.1-220.0 µg mL(-1) of albumin with a detection limit of 7.0 × 10(-3)  µg mL(-1). The relative standard deviations (RSD) for six replicate measurements of albumin were calculated as 2.2%, 1.7% and 1.3% for 0.5, 10.0 and 100.0 µg mL(-1) albumin, respectively. Furthermore the proposed method has been employed for the determination of albumin in human serum and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Microcontroller-based system for estimate of calcium in serum samples.

    Science.gov (United States)

    Neelamegam, Periyaswmy; Jamaludeen, Abdul Sheriff; Ragendran, Annamalai; Murugrananthan, Krishanamoorthy

    2010-01-01

    In this study, a microcontroller-based control unit was designed and constructed for the estimation of serum calcium in blood samples. The proposed optoelectronic instrument used a red light emitting diode (LED) as a light source and photodiode as a sensor. The performance of the system was compared with that of a commercial instrument in measuring calcium ion. The quantitative analysis of calcium in a catalyst using arsenazo III as colorimetric reagent was used to test the device. The calibration curve for calcium binding with arsenazo III was drawn to check the range of linearity, which was between 0.1 to 4.5 mM L⁻¹. The limit of detection (LOD) is 0.05 mM L⁻¹. Absorbance changes over the pH range of 2-12 were determined to optimize the assay, with maximum absorption at pH 9.0. Interferences in absorbance from monovalent (K+ and Na+) and divalent (Mg²+) cations were also studied. The results show that the system works successfully.

  17. microRNA Biomarker Discovery and High-Throughput DNA Sequencing Are Possible Using Long-term Archived Serum Samples.

    Science.gov (United States)

    Rounge, Trine B; Lauritzen, Marianne; Langseth, Hilde; Enerly, Espen; Lyle, Robert; Gislefoss, Randi E

    2015-09-01

    The impacts of long-term storage and varying preanalytical factors on the quality and quantity of DNA and miRNA from archived serum have not been fully assessed. Preanalytical and analytical variations and degradation may introduce bias in representation of DNA and miRNA and may result in loss or corruption of quantitative data. We have evaluated DNA and miRNA quantity, quality, and variability in samples stored up to 40 years using one of the oldest prospective serum collections in the world, the Janus Serumbank, a biorepository dedicated to cancer research. miRNAs are present and stable in archived serum samples frozen at -25°C for at least 40 years. Long-time storage did not reduce miRNA yields; however, varying preanalytical conditions had a significant effect and should be taken into consideration during project design. Of note, 500 μL serum yielded sufficient miRNA for qPCR and small RNA sequencing and on average 650 unique miRNAs were detected in samples from presumably healthy donors. Of note, 500 μL serum yielded sufficient DNA for whole-genome sequencing and subsequent SNP calling, giving a uniform representation of the genomes. DNA and miRNA are stable during long-term storage, making large prospectively collected serum repositories an invaluable source for miRNA and DNA biomarker discovery. Large-scale biomarker studies with long follow-up time are possible utilizing biorepositories with archived serum and state-of-the-art technology. ©2015 American Association for Cancer Research.

  18. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    International Nuclear Information System (INIS)

    Andrada, Daniel; Pinto, Frederico G.; Magalhaes, Cristina Goncalves; Nunes, Berta R.; Silva, Jose Bento Borba da; Franco, Milton B.

    2006-01-01

    The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ETAAS). Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 μL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO 3 1% v/v and 0.02% v/v of cetyl trimethyl ammonium chloride (CTAC) were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 μL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 μg), the best pyrolysis and atomization temperatures were 900 and 1600 deg C, respectively, with a characteristic mass of 12 pg (recommended of 10 pg), with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence) for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh) and between 93.9 and 105.2% (Zr+Rh). In both recovery studies, the relative standard deviation (n=3) was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r 2 higher than 0.99. The limits of detection were 0.7 μg L -1 for serum samples, with Zr+Rh permanent, and 1.0 μg L -1 for urine with iridium permanent. (author)

  19. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    Directory of Open Access Journals (Sweden)

    Andrada Daniel

    2006-01-01

    Full Text Available The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ET AAS. Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 µL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO3 1% v/v and 0.02% v/v of cetil trimethyl ammonium chloride (CTAC were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 µL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 µg, the best pyrolysis and atomization temperatures were 900 and 1600 ºC, respectively, with a characteristic mass of 12 pg (recommended of 10 pg, with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh and between 93.9 and 105.2% (Zr+Rh. In both recovery studies, the relative standard deviation (n=3 was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r² higher than 0.99. The limits of detection were 0.7 µg L-1 for serum samples, with Zr+Rh permanent, and 1.0 µg L-1 for urine with iridium permanent.

  20. Development and application of an on-line sequential injection system for the separation of artificial and natural radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Kim, C.-K.; Sansone, U.; Martin, P.; Kim, C.-S.

    2007-02-01

    The Chemistry Unit of the Physics, Chemistry and Instrumentation Laboratory in the IAEA's Seibersdorf Laboratory in Austria, has the programmatic responsibility to provide assistance to Member State laboratories in maintaining and improving the reliability of analytical measurement results, both in trace element and radionuclide determinations. This is accomplished through the provision of reference materials of terrestrial origin, validated analytical procedures, training in the implementation of internal quality control, and through the evaluation of measurement performance by organization of worldwide and regional interlaboratory comparison exercises. In this framework an on-line sequential injection (SI) system was developed, which can be widely used for the separation and preconcentration of target analytes from diverse environmental samples. The system enables the separation time to be shortened by maintaining a constant flow rate of solution and by avoiding clogging or bubbling in a chromatographic column. The SI system was successfully applied to the separation of Pu in IAEA reference material (IAEA Soil-6) and to the sequential separation of 210 Po and 210 Pb in phosphogypsum candidate reference material. The replicate analysis results of Pu in IAEA reference material (Soil-6) obtained with the SI system are in good agreement with the recommended value within 5% of standard deviation. The SI system enabled a halving in the separation time required for of radionuclides

  1. Soluble CD44 concentration in the serum and peritoneal fluid samples of patients with different stages of endometriosis.

    Science.gov (United States)

    Mashayekhi, Farhad; Aryaee, Hadis; Mirzajani, Ebrahim; Yasin, Ashraf Ale; Fathi, Abdolsatar

    2015-09-01

    Endometriosis is a gynecological disease defined by the histological presence of endometrial glands and stroma outside the uterine cavity, most commonly implanted over visceral and peritoneal surface within the female pelvis. CD44 is a membrane protein expressed by human endometrial cells, and it has been shown to promote the adhesion of endometrial cells. The aim of this study was to determine the levels of soluble CD44 (sCD44) in the serum and peritoneal fluid (PF) samples of patients with different stages of endometriosis. 39 PF and serum samples from normal healthy and 130 samples from different stages of patients with endometriosis (33 cases of stage I, 38 stage II, 30 stage III and 29 stage IV) were included in this study. Total protein concentration (TPC) and the level of s-cMet in the serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay, respectively. No significant change in the TPC was seen in the serum of patients with endometriosis when compared to normal controls. Results obtained demonstrated that all serum and peritoneal fluid samples, presented sCD44 expression, whereas, starting from stages I to IV endometriosis, a significant increase of sCD44 expression was observed as compared to control group. The results of this study show that a high expression of sCD44 is correlated with advanced stages of endometriosis. It is also concluded that the detection of serum and/or peritoneal fluid sCD44 may be useful in classifying endometriosis.

  2. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    International Nuclear Information System (INIS)

    Fliniaux, Ophélie; Gaillard, Gwenaelle; Lion, Antoine; Cailleu, Dominique; Mesnard, François; Betsou, Fotini

    2011-01-01

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4°C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4°C. Five or ten serum freeze–thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  3. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Fliniaux, Ophelie [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Gaillard, Gwenaelle [Biobanque de Picardie (France); Lion, Antoine [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Cailleu, Dominique [Batiment Serres-Transfert, rue de Mai/rue Dallery, Plateforme Analytique (France); Mesnard, Francois, E-mail: francois.mesnard@u-picardie.fr [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Betsou, Fotini [Integrated Biobank of Luxembourg (Luxembourg)

    2011-12-15

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4 Degree-Sign C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4 Degree-Sign C. Five or ten serum freeze-thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  4. The use of enzyme-linked immunosorbent assay for detection of Mycoplasma hominis antibodies in infertile women serum samples

    DEFF Research Database (Denmark)

    Baczynska, Agata; Friis Svenstrup, Helle; Fedder, Jens

    2005-01-01

    BACKGROUND: Besides Chlamydiae trachomatis and Mycoplasma genitalium, Mycoplasma hominis may also cause infertility due to damage of the Fallopian tubes. Therefore serum samples from infertile women were analyzed for antibodies to M. hominis. METHODS: Sera from 304 infertile women were investigat...

  5. Resolution of a serum sample mix-up through the use of short tandem repeat DNA typing.

    Science.gov (United States)

    Allen, Robert W; Pritchard, Jane K

    2004-12-01

    A sample mix-up occurred in a tissue procurement laboratory in which aliquots of serum from two tissue donors were accidentally mislabeled. The clues to the apparent mixup involved discrepant Hepatitis C test results. In an attempt to resolve the apparent mix up, DNA typing was performed using serum samples as a possible source of genomic DNA. Two hundred microliter aliquots of two reference sera and aliquots prepared from them were subjected to DNA extraction. PCR amplification of 9 STR loci was performed on the extracts and amplicons were analyzed by capillary electrophoresis. About 1 microg/ml of DNA was recovered from all serum samples and was of sufficient quality to direct the amplification of most, if not all STR loci allowing the mislabeled specimens to be traced to the proper tissue donor. Serum is a useful source of genomic DNA for STR analysis in situations in which such samples are the only source of DNA for testing. Interestingly, one of the tissue donors on life support and repeatedly receiving blood products, exhibited a mixed DNA profile indicative of the presence of DNA from multiple individuals in the bloodstream.

  6. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, S.; Wallace, A.M.; Cook, B. (Stobhill Hospital, Glasgow (England))

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.

  7. A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    International Nuclear Information System (INIS)

    Thomson, S.; Wallace, A.M.; Cook, B.

    1989-01-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking [ 125 I]iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-[ 125 I]iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia

  8. A Procedure for the Sequential Determination of Radionuclides in Environmental Samples. Liquid Scintillation Counting and Alpha Spectrometry for 90Sr, 241Am and Pu Radioisotopes

    International Nuclear Information System (INIS)

    2014-01-01

    Since 2004, IAEA activities related to the terrestrial environment have aimed at the development of a set of procedures to determine radionuclides in environmental samples. Reliable, comparable and ‘fit for purpose’ results are an essential requirement for any decision based on analytical measurements. For the analyst, tested and validated analytical procedures are extremely important tools for the production of analytical data. For maximum utility, such procedures should be comprehensive, clearly formulated and readily available for reference to both the analyst and the customer. This publication describes a combined procedure for the sequential determination of 90 Sr, 241 Am and Pu radioisotopes in environmental samples. The method is based on the chemical separation of strontium, americium and plutonium using ion exchange chromatography, extraction chromatography and precipitation followed by alpha spectrometric and liquid scintillation counting detection. The method was tested and validated in terms of repeatability and trueness in accordance with International Organization for Standardization (ISO) guidelines using reference materials and proficiency test samples. Reproducibility tests were performed later at the IAEA Terrestrial Environment Laboratory. The calculations of the massic activity, uncertainty budget, decision threshold and detection limit are also described in this publication. The procedure is introduced for the determination of 90 Sr, 241 Am and Pu radioisotopes in environmental samples such as soil, sediment, air filter and vegetation samples. It is expected to be of general use to a wide range of laboratories, including the Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) network for routine environmental monitoring purposes

  9. Limited interlaboratory comparison of Schmallenberg virus antibody detection in serum samples

    DEFF Research Database (Denmark)

    van der Poel, W. H. M.; Cay, B.; Zientara, S.

    2014-01-01

    Eight veterinary institutes in seven different countries in Europe participated in a limited interlaboratory comparison trial to evaluate laboratory performances of Schmallenberg virus (SBV) antibody detection in serum. Seven different sheep sera and three different cattle sera were circulated, a...

  10. Estimations of cholesterol, triglycerides and fractionation of lipoproteins in serum samples of some Nigerian female subjects

    Directory of Open Access Journals (Sweden)

    E.I. Adeyeye

    2011-04-01

    Full Text Available Blood samples (serum were collected to determine some biochemical parameters: total glycerides (TG, total cholesterol (TC, high density lipoprotein-cholesterol (HDL-C, low density lipoprotein-cholesterol (LDL-C and very low density lipoprotein-cholesterol (VLDL-C in 53 female subjects in Warri, Delta State, Nigeria using the Reflotron® (an auto analyser, supported with the use of questionnaire to get information on age and sex. Age range of the subjects was 18–80 years. The TG levels in all the subjects were < 200 mg/dL; only one subject (1.89% had TC < 200 mg/dL; nine subjects (17.0% had HDL-C ≤ 35 mg/dL; for LDL-C only one subject (1.89% had a desirable level of < 130 mg/dL; for VLDL-C 29 subjects (54.7% had values 17.2 mg/dL and above. For therapeutic decision-making, TC/HDL-C and LDL-C/HDL-C, were calculated. In TC/HDL-C, three subjects (5.66% had values < 4.4 and in LDL-C/HDL-C, 41 subjects (77.4% had values < 4.5. Hence, TC, HDL-C, LDL-C, TC/HDL-C and slightly LDL-C/HDL-C and VLDL-C in the subjects could lead to increase coronary heart diseases. Results were matched for the age and sex of subjects.

  11. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  12. Optimizing trial design in pharmacogenetics research: comparing a fixed parallel group, group sequential, and adaptive selection design on sample size requirements.

    Science.gov (United States)

    Boessen, Ruud; van der Baan, Frederieke; Groenwold, Rolf; Egberts, Antoine; Klungel, Olaf; Grobbee, Diederick; Knol, Mirjam; Roes, Kit

    2013-01-01

    Two-stage clinical trial designs may be efficient in pharmacogenetics research when there is some but inconclusive evidence of effect modification by a genomic marker. Two-stage designs allow to stop early for efficacy or futility and can offer the additional opportunity to enrich the study population to a specific patient subgroup after an interim analysis. This study compared sample size requirements for fixed parallel group, group sequential, and adaptive selection designs with equal overall power and control of the family-wise type I error rate. The designs were evaluated across scenarios that defined the effect sizes in the marker positive and marker negative subgroups and the prevalence of marker positive patients in the overall study population. Effect sizes were chosen to reflect realistic planning scenarios, where at least some effect is present in the marker negative subgroup. In addition, scenarios were considered in which the assumed 'true' subgroup effects (i.e., the postulated effects) differed from those hypothesized at the planning stage. As expected, both two-stage designs generally required fewer patients than a fixed parallel group design, and the advantage increased as the difference between subgroups increased. The adaptive selection design added little further reduction in sample size, as compared with the group sequential design, when the postulated effect sizes were equal to those hypothesized at the planning stage. However, when the postulated effects deviated strongly in favor of enrichment, the comparative advantage of the adaptive selection design increased, which precisely reflects the adaptive nature of the design. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  14. Mobility of arsenic, cadmium and zinc in a multi-element contaminated soil profile assessed by in-situ soil pore water sampling, column leaching and sequential extraction

    International Nuclear Information System (INIS)

    Beesley, Luke; Moreno-Jimenez, Eduardo; Clemente, Rafael; Lepp, Nicholas; Dickinson, Nicholas

    2010-01-01

    Three methods for predicting element mobility in soils have been applied to an iron-rich soil, contaminated with arsenic, cadmium and zinc. Soils were collected from 0 to 30 cm, 30 to 70 cm and 70 to 100 cm depths in the field and soil pore water was collected at different depths from an adjacent 100 cm deep trench. Sequential extraction and a column leaching test in the laboratory were compared to element concentrations in pore water sampled directly from the field. Arsenic showed low extractability, low leachability and occurred at low concentrations in pore water samples. Cadmium and zinc were more labile and present in higher concentrations in pore water, increasing with soil depth. Pore water sampling gave the best indication of short term element mobility when field conditions were taken into account, but further extraction and leaching procedures produced a fuller picture of element dynamics, revealing highly labile Cd deep in the soil profile. - Mobility of arsenic, cadmium and zinc in a polluted soil can be realistically interpreted by in-situ soil pore water sampling.

  15. Sequential determination of nickel and cadmium in tobacco, molasses and refill solutions for e-cigarettes samples by molecular fluorescence.

    Science.gov (United States)

    Talio, María Carolina; Alesso, Magdalena; Acosta, Mariano; Wills, Verónica S; Fernández, Liliana P

    2017-11-01

    In this work, a new procedure was developed for separation and preconcentration of nickel(II) and cadmium(II) in several and varied tobacco samples. Tobacco samples were selected considering the main products consumed by segments of the population, in particular the age (youth) and lifestyle of the consumer. To guarantee representative samples, a randomized strategy of sampling was used. In the first step, a chemofiltration on nylon membrane is carried out employing eosin (Eo) and carbon nanotubes dispersed in sodium dodecylsulfate (SDS) solution (phosphate buffer pH 7). In this condition, Ni(II) was selectively retained on the solid support. After that, the filtrate liquid with Cd(II) was re-conditioned with acetic acid /acetate buffer solution (pH 5) and followed by detection. A spectrofluorimetric determination of both metals was carried out, on the solid support and the filtered aqueous solution, for Ni(II) and Cd(II), respectively. The solid surface fluorescence (SSF) determination was performed at λ em = 545nm (λ ex = 515nm) for Ni(II)-Eo complex and the fluorescence of Cd(II)-Eo was quantified in aqueous solution using λ em = 565nm (λ ex = 540nm). The calibration graphs resulted linear in a range of 0.058-29.35μgL -1 for Ni(II) and 0.124-56.20μgL -1 for Cd(II), with detection limits of 0.019 and 0.041μgL -1 (S/N = 3). The developed methodology shows good sensitivity and adequate selectivity, and it was successfully applied to the determination of trace amounts of nickel and cadmium present in tobacco samples (refill solutions for e-cigarettes, snuff used in narguille (molasses) and traditional tobacco) with satisfactory results. The new methodology was validated by ICP-MS with adequate agreement. The proposed methodology represents a novel fluorescence application to Ni(II) and Cd(II) quantification with sensitivity and accuracy similar to atomic spectroscopies, introducing for the first time the quenching effect on SSF. Copyright © 2017 Elsevier B

  16. Chemometrics enhanced HPLC-DAD performance for rapid quantification of carbamazepine and phenobarbital in human serum samples.

    Science.gov (United States)

    Vosough, Maryam; Ghafghazi, Shiva; Sabetkasaei, Masoumeh

    2014-02-01

    This paper describes development and validation of a simple and efficient bioanalytical procedure for simultaneous determination of phenobarbital and carbamazepine in human serum samples using high performance liquid chromatography with photodiode-array detection (HPLC-DAD) regarding a fast elution methodology in less than 5 min. Briefly, this method consisted of a simple deproteinization step of serum samples followed by HPLC analysis on a Bonus-RP column using an isocratic mode of elution with acetonitrile/K2HPO4 (pH=7.5) buffer solution (45:55). Due to the presence of serum endogenous components as non-calibrated components in the sample, second-order calibration based on multivariate curve resolution-alternating least squares (MCR-ALS), has been applied on a set of absorbance matrices collected as a function of retention time and wavelengths. Acceptable resolution and quantification results were achieved in the presence of matrix interferences and the second-order advantage was fully exploited. The average recoveries for carbamazepine and phenobarbital were 89.7% and 86.1% and relative standard deviation values were lower than 9%. Additionally, computed elliptical joint confidence region (EJCR) confirmed the accuracy of the proposed method and indicated the absence of both constant and proportional errors in the predicted concentrations. The developed method enabled the determination of the analytes in different serum samples in the presence of overlapped profiles, while keeping experimental time and extraction steps at minimum. Finally, the serum concentration levels of carbamazepine in three time intervals were reported for morphine-dependents who had received carbamazepine for treating their neuropathic pain. © 2013 Elsevier B.V. All rights reserved.

  17. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  18. Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.

    Science.gov (United States)

    Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen

    2016-12-01

    Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.

  19. Source Identification and Sequential Leaching of Heavy Metals in Soil Samples Collected from Selected Dump Sites in Ekiti State, Nigeria

    OpenAIRE

    , E.E. Awokunmi; , S.S. Asaolu; , O.O Ajayi; , A.O. Adebayo

    2011-01-01

    Ten heavy metals (Fe, Cu, Mn, Zn, Pb, Ni, Co, Cd, Cr and Sn) in fractioned and bulk soil samples collected from four dump sites located in AdoEkiti and Ikere -Ekiti, South western Nigeria were analysed using a modified Tessier’s procedure and acid digestion to obtain the distribution pattern of metal in this region. The metals were found to have been distributed in all phases with Fe, Cr, and Sn dominating the residual fraction (90.12 - 94.88%), Co, Ni, Cu, and Zn were found in all the extrac...

  20. EXPERIMENTS TOWARDS DETERMINING BEST TRAINING SAMPLE SIZE FOR AUTOMATED EVALUATION OF DESCRIPTIVE ANSWERS THROUGH SEQUENTIAL MINIMAL OPTIMIZATION

    Directory of Open Access Journals (Sweden)

    Sunil Kumar C

    2014-01-01

    Full Text Available With number of students growing each year there is a strong need to automate systems capable of evaluating descriptive answers. Unfortunately, there aren’t many systems capable of performing this task. In this paper, we use a machine learning tool called LightSIDE to accomplish auto evaluation and scoring of descriptive answers. Our experiments are designed to cater to our primary goal of identifying the optimum training sample size so as to get optimum auto scoring. Besides the technical overview and the experiments design, the paper also covers challenges, benefits of the system. We also discussed interdisciplinary areas for future research on this topic.

  1. Serum copper and zinc concentrations in a representative sample of the Canarian population.

    Science.gov (United States)

    Díaz Romero, Carlos; Henríquez Sánchez, Patricia; López Blanco, Félix; Rodríguez Rodríguez, Elena; Serra Majem, Lluis

    2002-01-01

    Serum copper (Cu) and zinc (Zn) concentrations of 395 individuals (187 males + 208 females) living in Canary Islands were determined by flame atomic absorption spectrometry. The mean copper and zinc concentrations were 1.10 +/- 0.25 mg/L and 1.16 +/- 0.52 mg/L respectively. Our data were similar to other data published in other Spanish regions. Individuals from Lanzarote presented a mean Cu and Zn concentrations higher (p EL Hierro showed the lowest (p 0.05) among the different age intervals. No clear trends in the serum Cu and Zn concentrations were observed when drinking and smoking habits were considered. The increase of physical exercise reduced (p < 0.05) the serum Cu concentrations.

  2. Sequential Banking.

    OpenAIRE

    Bizer, David S; DeMarzo, Peter M

    1992-01-01

    The authors study environments in which agents may borrow sequentially from more than one leader. Although debt is prioritized, additional lending imposes an externality on prior debt because, with moral hazard, the probability of repayment of prior loans decreases. Equilibrium interest rates are higher than they would be if borrowers could commit to borrow from at most one bank. Even though the loan terms are less favorable than they would be under commitment, the indebtedness of borrowers i...

  3. SELDI-TOF MS of quadruplicate urine and serum samples to evaluate changes related to storage conditions.

    Science.gov (United States)

    Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D

    2006-03-01

    Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.

  4. Correlation of Cadmium and Magnesium in the Blood and Serum Samples of Smokers and Non-Smokers Chronic Leukemia Patients.

    Science.gov (United States)

    Khan, Noman; Afridi, Hasan Imran; Kazi, Tasneem Gul; Arain, Muhammad Balal; Bilal, Muhammad; Akhtar, Asma; Khan, Mustafa

    2017-03-01

    It was studied that cancer-causing processes are related with the disproportions of essential and toxic elements in body tissues and fluid. The purpose of the current study was to evaluate the levels of magnesium (Mg) and cadmium (Cd) in serum and blood samples of smokers and nonsmokers who have chronic myeloid (CML) and lymphocytic (CLL) leukemia, age ranged 31-50 years. For comparative study, age-matched smokers and nonsmoker males were chosen as controls/referents. The levels of elements in patient were analyzed before any treatment by atomic absorption spectrophotometer, after microwave assisted acid digestion. The validation of the method was done by using certified reference materials of serum and blood samples. The resulted data indicated that the adult male smokers and nonsmokers have two- to fourfold higher levels of Cd in the blood and sera samples as compared to the referents (p blood and serum samples of both types of leukemia patients as related to referent values. The resulted data indicates significant negative correlation among Mg and Cd in leukemia patients and smoker referents. Further studies are needed to clarify the role of these elements in pathogenesis of chronic leukemia.

  5. Radioimmunological assay of alpha-fetoprotein concentrations in blood serum samples from women in the first half of gestation

    International Nuclear Information System (INIS)

    Chomanski, M.; Grzes, A.

    1977-01-01

    In 66 unpregnant women and in 199 pregnant subjects (in the first half of pregnancy) the alpha-fetoprotein (α-FP) concentrations were determined in peripheric blood-serum samples. The α-FP was determined using radioimmunoo-assay technique where the addition of I 125 labelled protein was preceded by 3 hours lasting preincubation period. The free protein was separated from the bound by means of precipitation with a mixture of 96% ethanol and 34.5% ammonium acetate in a ratio 77.5 : 22.5. The patients were grouped into 5 subgroups according to the gestational age. The mean values of α-FP concentration demonstrated a steady increase along with the advancement of gestation. It is suggested that the concentration of this protein in the blood-serum samples may serve as a valuable parameter for the study of gestation development and the state of the fetus. (author)

  6. A highly selective and sensitive Tb3+-acetylacetone photo probe for the assessment of acetazolamide in pharmaceutical and serum samples

    Science.gov (United States)

    Youssef, A. O.

    2018-04-01

    A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of Acetazolamide in pharmaceutical tablets and serum samples using photo probe Tb3+-ACAC. The Acetazolamide can remarkably quench the luminescence intensity of Tb3+-ACAC complex in DMSO at pH 6.8 and λex = 350 nm. The quenching of luminescence intensity of Tb3+-ACAC complex especially the electrical band at λem = 545 nm is used for the assessment of Acetazolamide in the pharmaceutical tablet and serum samples. The dynamic range found for the determination of Acetazolamide concentration is 4.49 × 10-9-1.28 × 10-7 mol L-1, and the limit of detection (LOD) and limit of quantification (LOQ) are (4.0 × 10-9 and 1.21 × 10-8) mol L-1, respectively.

  7. The relationships between sixteen perfluorinated compound concentrations in blood serum and food, and other parameters, in the general population of South Korea with proportionate stratified sampling method.

    Science.gov (United States)

    Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun

    2014-02-01

    Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from studies. We confirmed from the relationships between questionnaire results and the PFC concentrations in the serum samples, that food is one of the important contribution factors of human exposure to PFCs. However, there were no correlations between the PFC concentrations in the one day composite diet samples and the serum samples, because a one day composite diet sample is not necessarily representative of a person's long-term diet and because of the small number of samples taken. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Qiao Jixin, E-mail: jixin.qiao@risoe.d [Radiation Research Division, Riso National Laboratory for Sustainable Energy, Technical University of Denmark, DK-4000 Roskilde (Denmark); Hou Xiaolin; Roos, Per [Radiation Research Division, Riso National Laboratory for Sustainable Energy, Technical University of Denmark, DK-4000 Roskilde (Denmark); Miro, Manuel [Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, Carretera de Valldemossa km. 7.5, E-07122 Palma de Mallorca, Illes Balears (Spain)

    2011-01-31

    This paper reports an automated analytical method for rapid determination of plutonium isotopes ({sup 239}Pu and {sup 240}Pu) in environmental solid extracts. Anion exchange chromatographic columns were incorporated in a sequential injection (SI) system to undertake the automated separation of plutonium from matrix and interfering elements. The analytical results most distinctly demonstrated that the crosslinkage of the anion exchanger is a key parameter controlling the separation efficiency. AG 1-x4 type resin was selected as the most suitable sorbent material for analyte separation. Investigation of column size effect upon the separation efficiency revealed that small-sized (2 mL) columns sufficed to handle up to 50 g of environmental soil samples. Under the optimum conditions, chemical yields of plutonium exceeded 90% and the decontamination factors for uranium, thorium and lead ranged from 10{sup 3} to 10{sup 4}. The determination of plutonium isotopes in three standard/certified reference materials (IAEA-375 soil, IAEA-135 sediment and NIST-4359 seaweed) and two reference samples (Irish Sea sediment and Danish soil) revealed a good agreement with reference/certified values. The SI column-separation method is straightforward and less labor intensive as compared with batch-wise anion exchange chromatographic procedures. Besides, the automated method features low consumption of ion-exchanger and reagents for column washing and elution, with the consequent decrease in the generation of acidic waste, thus bearing green chemical credentials.

  9. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    Directory of Open Access Journals (Sweden)

    Camila Ximenes

    2014-12-01

    Full Text Available The Global Program for the Elimination of Lymphatic Filariasis (GPELF aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2 and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2, which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  10. Restricted access carbon nanotubes for direct extraction of cadmium from human serum samples followed by atomic absorption spectrometry analysis.

    Science.gov (United States)

    Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C

    2015-01-01

    In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from

  11. A comparative study of some physico-chemical properties of human serum albumin samples from different sources--I : Some physico-chemical properties of isoionic human serum albumin solutions

    NARCIS (Netherlands)

    Dröge, J.H.M.; Janssen, L.H.M.; Wilting, J.

    1982-01-01

    Human serum albumin samples from different sources were investigated. The fatty acid content of the albumin before and after deionization on a mixed bed ion-exchange column varied from sample to sample. When an albumin sample from one source was deionized under standard conditions the amount of

  12. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    Science.gov (United States)

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  13. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  14. Sequential injection chromatography with post-column reaction/derivatization for the determination of transition metal cations in natural water samples.

    Science.gov (United States)

    Horstkotte, Burkhard; Jarošová, Patrícia; Chocholouš, Petr; Sklenářová, Hana; Solich, Petr

    2015-05-01

    In this work, the applicability of Sequential Injection Chromatography for the determination of transition metals in water is evaluated for the separation of copper(II), zinc(II), and iron(II) cations. Separations were performed using a Dionex IonPAC™ guard column (50mm×2mm i.d., 9 µm). Mobile phase composition and post-column reaction were optimized by modified SIMPLEX method with subsequent study of the concentration of each component. The mobile phase consisted of 2,6-pyridinedicarboxylic acid as analyte-selective compound, sodium sulfate, and formic acid/sodium formate buffer. Post-column addition of 4-(2-pyridylazo)resorcinol was carried out for spectrophotometric detection of the analytes׳ complexes at 530nm. Approaches to achieve higher robustness, baseline stability, and detection sensitivity by on-column stacking of the analytes and initial gradient implementation as well as air-cushion pressure damping for post-column reagent addition were studied. The method allowed the rapid separation of copper(II), zinc(II), and iron(II) within 6.5min including pump refilling and aspiration of sample and 1mmol HNO3 for analyte stacking on the separation column. High sensitivity was achieved applying an injection volume of up to 90µL. A signal repeatability of<2% RSD of peak height was found. Analyte recovery evaluated by spiking of different natural water samples was well suited for routine analysis with sub-micromolar limits of detection. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Stir-bar supported micro-solid-phase extraction for the determination of polychlorinated biphenyl congeners in serum samples.

    Science.gov (United States)

    Sajid, Muhammad; Basheer, Chanbasha

    2016-07-15

    In present work, a new configuration of micro-solid phase extraction was introduced and termed as stir-bar supported micro-solid-phase extraction (SB-μ-SPE). A tiny stir-bar was packed inside the porous polypropylene membrane along with sorbent material and the edges of membrane sheet were heat sealed to secure the contents. The packing of stir-bar inside the μ-SPE device does not allow the device to stick with the wall or any corner of the sample vial during extraction, which is, however, a frequent observation in routine μ-SPE. Moreover, it enhances effective surface area of the sorbent exposed to sample solution through continuous agitation (motion and rotation). It also completely immerses the SB-μ-SPE device in the sample solution even for non-polar sorbents. Polychlorinated biphenyls (PCBs) were selected as model compounds and the method performance was evaluated in human serum samples. After extraction, samples were analyzed by gas chromatography mass spectrometry (GC-MS). The factors that affect extraction efficiency of SB-μ-SPE were optimized. Under optimum conditions, a good linearity (0.1-100ngmL(-1)) with coefficients of determinations ranging from 0.9868 to 0.9992 was obtained. Limits of detections were ranged between 0.003 and 0.047ngmL(-1). Acceptable values for inter-day (3.2-9.1%) and intra-day (3.1-7.2%) relative standard deviations were obtained. The optimized method was successfully applied to determine the concentration of PCB congeners in human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Mohammadpour

    2013-01-01

    Full Text Available Objective(s:The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg cartridges or with direct precipitation using acetonitrile. Results:The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study

  18. Changes in alt, ast and alp values of plasma and serum samples ...

    African Journals Online (AJOL)

    Blood samples were obtained from a total of 20 patients that presented with cases of liver malfunction at the Ebonyi State University Teaching Hospital, Abakaliki, Nigeria. The enzyme assays were carried out immediately upon sample collection and separation to obtain the baseline value (BV), and thereafter at specified ...

  19. Surface plasmon resonance immunoassay analysis of pituitary hormones in urine and serum samples.

    Science.gov (United States)

    Treviño, Juan; Calle, Ana; Rodríguez-Frade, José Miguel; Mellado, Mario; Lechuga, Laura M

    2009-05-01

    Direct determination of four pituitary peptide hormones: human thyroid stimulating hormone (hTSH), growth hormone (hGH), follicle stimulating hormone (hFSH), and luteinizing hormone (hLH) has been carried out using a portable surface plasmon resonance (SPR) immunosensor. A commercial SPR biosensor was employed. The immobilization of the hormones was optimized and monoclonal antibodies were selected in order to obtain the best sensor performance. Assay parameters as running buffer and regeneration solution composition or antibody concentration were adjusted to achieve a sensitive analyte detection. The performance of the assays was assessed in buffer solution, serum and urine, showing sensitivity in the range from 1 to 6 ng/mL. The covalent attachment of the hormones ensured the stability of the SPR signal through repeated use in up to 100 consecutive assay cycles. Mean intra- and inter-day coefficients of variation were all <7%, while batch-assay variability using different sensor surfaces was <5%. Taking account both the excellent reutilization performance and the outstanding reproducibility, this SPR immunoassay method turns on a highly reliable tool for endocrine monitoring in laboratory and point-of-care (POC) settings.

  20. Identification of Reliable Reference Genes for Quantification of MicroRNAs in Serum Samples of Sulfur Mustard-Exposed Veterans.

    Science.gov (United States)

    Gharbi, Sedigheh; Shamsara, Mehdi; Khateri, Shahriar; Soroush, Mohammad Reza; Ghorbanmehr, Nassim; Tavallaei, Mahmood; Nourani, Mohammad Reza; Mowla, Seyed Javad

    2015-01-01

    In spite of accumulating information about pathological aspects of sulfur mustard (SM), the precise mechanism responsible for its effects is not well understood. Circulating microRNAs (miRNAs) are promising biomarkers for disease diagnosis and prognosis. Accurate normalization using appropriate reference genes, is a critical step in miRNA expression studies. In this study, we aimed to identify appropriate reference gene for microRNA quantification in serum samples of SM victims. In this case and control experimental study, using quantitative real-time polymerase chain reaction (qRT-PCR), we evaluated the suitability of a panel of small RNAs including SNORD38B, SNORD49A, U6, 5S rRNA, miR-423-3p, miR-191, miR-16 and miR-103 in sera of 28 SM-exposed veterans of Iran-Iraq war (1980-1988) and 15 matched control volunteers. Different statistical algorithms including geNorm, Normfinder, best-keeper and comparative delta-quantification cycle (Cq) method were employed to find the least variable reference gene. miR-423-3p was identified as the most stably expressed reference gene, and miR- 103 and miR-16 ranked after that. We demonstrate that non-miRNA reference genes have the least stabil- ity in serum samples and that some house-keeping miRNAs may be used as more reliable reference genes for miRNAs in serum. In addition, using the geometric mean of two reference genes could increase the reliability of the normalizers.

  1. A novel colorimetric method based on copper nanoclusters with intrinsic peroxidase-like for detecting xanthine in serum samples

    Science.gov (United States)

    Yan, Zhengyu; Niu, Qianqian; Mou, Mingyao; Wu, Yi; Liu, Xiaoxuan; Liao, Shenghua

    2017-07-01

    A facile strategy for detecting xanthine in serum samples by copper nanocluster (CuNCs) with high intrinsic peroxidase-like activity was reported. Firstly, a simple, mild and time-saving method for preparing CuNCs was developed, in which dithiothreitol (DTT) and bovine serum albumin (BSA) were used as reductant and stabilizer, respectively. The as-prepared CuNCs exhibited a fluorescence emission at 590 nm with a quantum yield (QY) of approximately 5.29%, the fluorescence intensity of the as-prepared CuNCs exhibited no considerable change when stored under ambient condition with the lifetime is 1.75 μs. Moreover, the as-prepared CuNCs exhibited high intrinsic peroxidase-like activity with lower K m ( K m = 8.90 × 10-6 mol L-1) for H2O2, which indicated that CuNCs have a higher affinity for H2O2. Compared with natural enzyme, the as-synthesized CuNCs are more catalytic stable over a wide range of pH (4.0 13.0) and temperature (4 80 °C). Finally, an indirect method for sensing xanthine was established because xanthine oxidase can catalyse the oxidation of xanthine to produce H2O2. Xanthine could be detected as low as 3.8 × 10-7 mol L-1 with a linear range from 5.0 × 10-7 to 1.0 × 10-4 mol L-1. These results proved that the proposed method is sensitive and accurate and could be successfully applied to the determination of xanthine in the serum sample with satisfaction.

  2. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  3. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  4. Spectrofluorimetric quantification of bilirubin using yttrium-norfloxacin complex as a fluorescence probe in serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Kamruzzaman, Mohammad; Alam, Al-Mahmnur [Department of Chemistry, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Hak Lee, Sang, E-mail: shlee@knu.ac.kr [Department of Chemistry, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Ho Kim, Young, E-mail: youngkim@knu.ac.kr [Research Institute of Advanced Energy Technology, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Gyu-Man [School of Mechanical Engineering, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Hyub Oh, Sang [Center for Gas Analysis, Korea Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of)

    2012-11-15

    A simple and sensitive spectrofluorimetric method was developed to determine trace amounts of bilirubin (BR) using yttrium (Y{sup 3+})-norfloxacin (NFLX) complex as a fluorescence (FL) probe. NFLX can form a stable binary complex with Y{sup 3+} and markedly enhances the weak FL signal of the NFLX. The FL intensity of the Y{sup 3+}-NFLX complex decreased significantly in the presence of BR in a buffer solution at pH=7.2. Under optimal conditions, the FL intensity decreased according to the BR concentration and showed a good linear relationship in the range of 0.03-2.3 {mu}g mL{sup -1} of BR with a correlation coefficient of 0.9988. The limit of detection for the determination of BR was 2.8 ng mL{sup -1} with a relative standard deviation (RSD) of 1.55% for five replicate determination of 0.05 {mu}g mL{sup -1} BR. The presented method offers higher sensitivity with simple instrumentation and was applied successfully in detecting BR at low concentrations. Highlights: Black-Right-Pointing-Pointer Weak FL signal of NFLX was enhanced at 419 nm by forming binary complex with Y{sup 3+}. Black-Right-Pointing-Pointer The FL intensity of Y{sup 3+}-NFLX complex was quenched markedly in the presence of ATP. Black-Right-Pointing-Pointer NFLX can transfer energy to Y{sup 3+} and BR and form the Y{sup 3+}-NFLX-ATP ternary complex. Black-Right-Pointing-Pointer The reduced FL intensity of the system was correlated with the concentration of BR. Black-Right-Pointing-Pointer The method is applied to determine BR at low concentration (2.8 ng mL{sup -1}) in serum.

  5. Automatic data acquisition and on-line analysis of trace element concentration in serum samples

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.

    1978-01-01

    A completely automated system has been developed to determine the trace element concentration in biological samples by measuring charged particle induced X-rays. A CDC-3100 computer with ADC and CAMAC interface is employed to control the data collection apparatus, acquire data and perform simultaneously the analysis. The experimental set-up consists of a large square plexiglass chamber in which a commercially available 750H Kodak Carousel is suitably arranged as a computer controlled sample changer. A method of extracting trace element concentrations using reference spectra is presented and an on-line program has been developed to easily and conveniently obtain final results at the end of each run. (Auth.)

  6. New method for simultaneous determination of 55Fe and 59Fe in blood serum samples

    International Nuclear Information System (INIS)

    Saukkonen, H.; Uhlenius, R.

    1978-01-01

    Routine methods for the measurement of 55 Fe and 59 Fe activities in biological samples are frequently required in metabolic studies of iron. A new simple method for the simultaneous determination of 59 Fe and 55 Fe concentration in 5 cm 3 samples of blood is described and carefully evaluated. Before the measurement of the activity, organic matter was eliminated by HNO 3 -HClO 4 wet ashing and iron was electroplated onto a copper plate. The accuracy of results was studied by assessing samples, which contained known amounts of radioactivity and determining the counts per nanocurie in each case. The accuracy of the results of 59 Fe and 55 Fe determinations was found to be about 5%. The method has been routinely used to determine iron resorption in patients using the double isotope method. The determination proved to be satisfactory and not too laborious. When performing the yield determination there is a way of detecting and correcting mistakes or incompleteness in different stages of the measurement, thus leading to a high degree of reliability. (T.G.)

  7. Detection of Merkel Cell Polyomavirus DNA in Serum Samples of Healthy Blood Donors

    Science.gov (United States)

    Mazzoni, Elisa; Rotondo, John C.; Marracino, Luisa; Selvatici, Rita; Bononi, Ilaria; Torreggiani, Elena; Touzé, Antoine; Martini, Fernanda; Tognon, Mauro G.

    2017-01-01

    Merkel cell polyomavirus (MCPyV) has been detected in 80% of Merkel cell carcinomas (MCC). In the host, the MCPyV reservoir remains elusive. MCPyV DNA sequences were revealed in blood donor buffy coats. In this study, MCPyV DNA sequences were investigated in the sera (n = 190) of healthy blood donors. Two MCPyV DNA sequences, coding for the viral oncoprotein large T antigen (LT), were investigated using polymerase chain reaction (PCR) methods and DNA sequencing. Circulating MCPyV sequences were detected in sera with a prevalence of 2.6% (5/190), at low-DNA viral load, which is in the range of 1–4 and 1–5 copies/μl by real-time PCR and droplet digital PCR, respectively. DNA sequencing carried out in the five MCPyV-positive samples indicated that the two MCPyV LT sequences which were analyzed belong to the MKL-1 strain. Circulating MCPyV LT sequences are present in blood donor sera. MCPyV-positive samples from blood donors could represent a potential vehicle for MCPyV infection in receivers, whereas an increase in viral load may occur with multiple blood transfusions. In certain patient conditions, such as immune-depression/suppression, additional disease or old age, transfusion of MCPyV-positive samples could be an additional risk factor for MCC onset. PMID:29238698

  8. Proteomic profiling of renal allograft rejection in serum using magnetic bead-based sample fractionation and MALDI-TOF MS.

    Science.gov (United States)

    Sui, Weiguo; Huang, Liling; Dai, Yong; Chen, Jiejing; Yan, Qiang; Huang, He

    2010-12-01

    Proteomics is one of the emerging techniques for biomarker discovery. Biomarkers can be used for early noninvasive diagnosis and prognosis of diseases and treatment efficacy evaluation. In the present study, the well-established research systems of ClinProt Micro solution incorporated unique magnetic bead sample preparation technology, which, based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), have become very successful in bioinformatics due to its outstanding performance and reproducibility for discovery disease-related biomarker. We collected fasting blood samples from patients with biopsy-confirmed acute renal allograft rejection (n = 12), chronic rejection (n = 12), stable graft function (n = 12) and also from healthy volunteers (n = 13) to study serum peptidome patterns. Specimens were purified with magnetic bead-based weak cation exchange chromatography and analyzed with a MALDI-TOF mass spectrometer. The results indicated that 18 differential peptide peaks were selected as potential biomarkers of acute renal allograft rejection, and 6 differential peptide peaks were selected as potential biomarkers of chronic rejection. A Quick Classifier Algorithm was used to set up the classification models for acute and chronic renal allograft rejection. The algorithm models recognize 82.64% of acute rejection and 98.96% of chronic rejection episodes, respectively. We were able to identify serum protein fingerprints in small sample sizes of recipients with renal allograft rejection and establish the models for diagnosis of renal allograft rejection. This preliminary study demonstrated that proteomics is an emerging tool for early diagnosis of renal allograft rejection and helps us to better understand the pathogenesis of disease process.

  9. Use of serum and blood samples on filter paper to improve the surveillance of Dengue in Pacific Island Countries.

    Science.gov (United States)

    Aubry, Maite; Roche, Claudine; Dupont-Rouzeyrol, Myrielle; Aaskov, John; Viallon, Jérôme; Marfel, Maria; Lalita, Paul; Elbourne-Duituturaga, Salanieta; Chanteau, Suzanne; Musso, Didier; Pavlin, Boris I; Harrison, Dustin; Kool, Jacob L; Cao-Lormeau, Van-Mai

    2012-09-01

    In Pacific Island Countries (PICs) the epidemiology of dengue is characterized by long-term transmission of a single dengue virus (DENV) serotype. The emergence of a new serotype in one island country often indicates major outbreaks with this serotype will follow in other PICs. Filter paper (FP) cards on which whole blood or serum from dengue suspected patients had been dried was evaluated as a method for transportation of this material by standard mail delivery throughout the Pacific. Twenty-two FP-dried whole blood samples collected from patients in New Caledonia and Wallis & Futuna Islands, during DENV-1 and DENV-4 transmission, and 76 FP-dried sera collected from patients in Yap State, Majuro (Republic of Marshall Islands), Tonga and Fiji, before and during outbreaks of DENV-2 in Yap State and DENV-4 in Majuro, were tested for the presence of DENV RNA, by serotype specific RT-PCR, at the Institut Louis Malardé in French Polynesia. The serotype of DENV could be determined, by a variety of RT-PCR procedures, in the FP-dried samples after more than three weeks of transport at ambient temperatures. In most cases, the sequencing of the envelope gene to genotype the viruses also was possible. The serotype and genotype of DENV can be determined from FP-dried serum or whole blood samples transported over thousands of kilometers at ambient, tropical, temperatures. This simple and low-cost approach to virus identification should be evaluated in isolated and resource poor settings for surveillance for a range of significant viral diseases. Copyright © 2012. Published by Elsevier B.V.

  10. Comparison of diagnostic methods to detect Histoplasma capsulatum in serum and blood samples from AIDS patients

    Science.gov (United States)

    da Silva, Marcos Vinicius; Criado, Paulo Ricardo; Luiz, Olinda do Carmo; Vicentini, Adriana Pardini

    2018-01-01

    Background Although early and rapid detection of histoplasmosis is essential to prevent morbidity and mortality, few diagnostic tools are available in resource-limited areas, especially where it is endemic and HIV/AIDS is also epidemic. Thus, we compared conventional and molecular methods to detect Histoplasma capsulatum in sera and blood from HIV/AIDS patients. Methodology We collected a total of 40 samples from control volunteers and patients suspected of histoplasmosis, some of whom were also infected with other pathogens. Samples were then analyzed by mycological, serological, and molecular methods, and stratified as histoplasmostic with (group I) or without AIDS (group II), uninfected (group III), and infected with HIV and other pathogens only (group IV). All patients were receiving treatment for histoplasmosis and other infections at the time of sample collection. Results Comparison of conventional methods with nested PCR using primers against H. capsulatum 18S rRNA (HC18S), 5.8S rRNA ITS (HC5.8S-ITS), and a 100 kDa protein (HC100) revealed that sensitivity against sera was highest for PCR with HC5.8S-ITS, followed by immunoblotting, double immunodiffusion, PCR with HC18S, and PCR with HC100. Specificity was equally high for double immunodiffusion, immunoblotting and PCR with HC100, followed for PCR with HC18S and HC5.8-ITS. Against blood, sensitivity was highest for PCR with HC5.8S-ITS, followed by PCR with HC18S, Giemsa staining, and PCR with HC100. Specificity was highest for Giemsa staining and PCR with HC100, followed by PCR with HC18S and HC5.8S-ITS. PCR was less efficient in patients with immunodeficiency due to HIV/AIDS and/or related diseases. Conclusion Molecular techniques may detect histoplasmosis even in cases with negative serology and mycology, potentially enabling early diagnosis. PMID:29342162

  11. Comparison of diagnostic methods to detect Histoplasma capsulatum in serum and blood samples from AIDS patients.

    Directory of Open Access Journals (Sweden)

    Katia Cristina Dantas

    Full Text Available Although early and rapid detection of histoplasmosis is essential to prevent morbidity and mortality, few diagnostic tools are available in resource-limited areas, especially where it is endemic and HIV/AIDS is also epidemic. Thus, we compared conventional and molecular methods to detect Histoplasma capsulatum in sera and blood from HIV/AIDS patients.We collected a total of 40 samples from control volunteers and patients suspected of histoplasmosis, some of whom were also infected with other pathogens. Samples were then analyzed by mycological, serological, and molecular methods, and stratified as histoplasmostic with (group I or without AIDS (group II, uninfected (group III, and infected with HIV and other pathogens only (group IV. All patients were receiving treatment for histoplasmosis and other infections at the time of sample collection.Comparison of conventional methods with nested PCR using primers against H. capsulatum 18S rRNA (HC18S, 5.8S rRNA ITS (HC5.8S-ITS, and a 100 kDa protein (HC100 revealed that sensitivity against sera was highest for PCR with HC5.8S-ITS, followed by immunoblotting, double immunodiffusion, PCR with HC18S, and PCR with HC100. Specificity was equally high for double immunodiffusion, immunoblotting and PCR with HC100, followed for PCR with HC18S and HC5.8-ITS. Against blood, sensitivity was highest for PCR with HC5.8S-ITS, followed by PCR with HC18S, Giemsa staining, and PCR with HC100. Specificity was highest for Giemsa staining and PCR with HC100, followed by PCR with HC18S and HC5.8S-ITS. PCR was less efficient in patients with immunodeficiency due to HIV/AIDS and/or related diseases.Molecular techniques may detect histoplasmosis even in cases with negative serology and mycology, potentially enabling early diagnosis.

  12. Polycyclic Aromatic Hydrocarbon Residues in Serum Samples of Autopsied Individuals from Tennessee

    Directory of Open Access Journals (Sweden)

    Aramandla Ramesh

    2014-12-01

    Full Text Available This study reports the concentrations of Polycyclic Aromatic Hydrocarbons (PAHs in human blood sera samples (n = 650 obtained at autopsy from individuals who died of drug abuse, alcohol toxicity, homicide, suicide and other unknown causes. The analyzed samples from decedents revealed the presence of PAHs of which B(aP was the most predominant one, followed by benzo(bfluoranthene and benzo(kfluoranthene. The other PAHs detected sporadically and measured were benzo(g,h,iperylene, acenaphthene, anthracene, phenanthrene, and fluoranthene The mean concentrations of PAHs were greater in the twenties to fifties age groups compared to others. The PAH residue levels detected were high in African Americans compared to Caucasians, Asians, and Hispanics. It appears that environmental exposure, dietary intake and in some cases occupational exposure may have contributed to the PAH body burden. While the PAH residue concentrations measured fall within the range of those reported for healthy adults elsewhere, in isolated cases, the concentrations detected were high, calling the need for a reduction in PAH emissions and human biomonitoring studies for purposes of risk assessment.

  13. Comprehensive metabolic characterization of serum osteocalcin action in a large non-diabetic sample.

    Directory of Open Access Journals (Sweden)

    Lukas Entenmann

    Full Text Available Recent research suggested a metabolic implication of osteocalcin (OCN in e.g. insulin sensitivity or steroid production. We used an untargeted metabolomics approach by analyzing plasma and urine samples of 931 participants using mass spectrometry to reveal further metabolic actions of OCN. Several detected relations between OCN and metabolites were strongly linked to renal function, however, a number of associations remained significant after adjustment for renal function. Intermediates of proline catabolism were associated with OCN reflecting the implication in bone metabolism. The association to kynurenine points towards a pro-inflammatory state with increasing OCN. Inverse relations with intermediates of branch-chained amino acid metabolism suggest a link to energy metabolism. Finally, urinary surrogate markers of smoking highlight its adverse effect on OCN metabolism. In conclusion, the present study provides a read-out of metabolic actions of OCN. However, most of the associations were weak arguing for a limited role of OCN in whole-body metabolism.

  14. Comprehensive metabolic characterization of serum osteocalcin action in a large non-diabetic sample.

    Science.gov (United States)

    Entenmann, Lukas; Pietzner, Maik; Artati, Anna; Hannemann, Anke; Henning, Ann-Kristin; Kastenmüller, Gabi; Völzke, Henry; Nauck, Matthias; Adamski, Jerzy; Wallaschofski, Henri; Friedrich, Nele

    2017-01-01

    Recent research suggested a metabolic implication of osteocalcin (OCN) in e.g. insulin sensitivity or steroid production. We used an untargeted metabolomics approach by analyzing plasma and urine samples of 931 participants using mass spectrometry to reveal further metabolic actions of OCN. Several detected relations between OCN and metabolites were strongly linked to renal function, however, a number of associations remained significant after adjustment for renal function. Intermediates of proline catabolism were associated with OCN reflecting the implication in bone metabolism. The association to kynurenine points towards a pro-inflammatory state with increasing OCN. Inverse relations with intermediates of branch-chained amino acid metabolism suggest a link to energy metabolism. Finally, urinary surrogate markers of smoking highlight its adverse effect on OCN metabolism. In conclusion, the present study provides a read-out of metabolic actions of OCN. However, most of the associations were weak arguing for a limited role of OCN in whole-body metabolism.

  15. Factors in selecting serum samples for use in determining the positive/negative threshold (cut-off) in ELISA

    International Nuclear Information System (INIS)

    Jacobson, R.H.

    1998-01-01

    The threshold (cut-off) that defines whether a test result is seropositive or seronegative is calculated by testing serum samples from a subpopulation of animals that is assumed to represent the target population in all aspects. For this proposition to be true, it is essential to consider the variables in the target population that must be represented in the subpopulation. Without representation of the variables in the subpopulation, it is likely that the cut-off selected for the test will be errant and will misclassify animals as to their infection status. The purpose of this paper is to identify a few of the principal variables that need to be taken into account when selecting a subpopulation of animals for test validation. (author)

  16. Sample Preparation Strategies for the Effective Quantitation of Hydrophilic Metabolites in Serum by Multi-Targeted HILIC-MS/MS

    Directory of Open Access Journals (Sweden)

    Elisavet Tsakelidou

    2017-03-01

    Full Text Available The effect of endogenous interferences of serum in multi-targeted metabolite profiling HILIC-MS/MS analysis was investigated by studying different sample preparation procedures. A modified QuEChERS dispersive SPE protocol, a HybridSPE protocol, and a combination of liquid extraction with protein precipitation were compared to a simple protein precipitation. Evaluation of extraction efficiency and sample clean-up was performed for all methods. SPE sorbent materials tested were found to retain hydrophilic analytes together with endogenous interferences, thus additional elution steps were needed. Liquid extraction was not shown to minimise matrix effects. In general, it was observed that a balance should be reached in terms of recovery, efficient clean-up, and sample treatment time when a wide range of metabolites are analysed. A quick step for removing phospholipids prior to the determination of hydrophilic endogenous metabolites is required, however, based on the results from the applied methods, further studies are needed to achieve high recoveries for all metabolites.

  17. High throughput and accurate serum proteome profiling by integrated sample preparation technology and single-run data independent mass spectrometry analysis.

    Science.gov (United States)

    Lin, Lin; Zheng, Jiaxin; Yu, Quan; Chen, Wendong; Xing, Jinchun; Chen, Chenxi; Tian, Ruijun

    2018-03-01

    Mass spectrometry (MS)-based serum proteome analysis is extremely challenging due to its high complexity and dynamic range of protein abundances. Developing high throughput and accurate serum proteomic profiling approach capable of analyzing large cohorts is urgently needed for biomarker discovery. Herein, we report a streamlined workflow for fast and accurate proteomic profiling from 1μL of blood serum. The workflow combined an integrated technique for highly sensitive and reproducible sample preparation and a new data-independent acquisition (DIA)-based MS method. Comparing with standard data dependent acquisition (DDA) approach, the optimized DIA method doubled the number of detected peptides and proteins with better reproducibility. Without protein immunodepletion and prefractionation, the single-run DIA analysis enables quantitative profiling of over 300 proteins with 50min gradient time. The quantified proteins span more than five orders of magnitude of abundance range and contain over 50 FDA-approved disease markers. The workflow allowed us to analyze 20 serum samples per day, with about 358 protein groups per sample being identified. A proof-of-concept study on renal cell carcinoma (RCC) serum samples confirmed the feasibility of the workflow for large scale serum proteomic profiling and disease-related biomarker discovery. Blood serum or plasma is the predominant specimen for clinical proteomic studies while the analysis is extremely challenging for its high complexity. Many efforts had been made in the past for serum proteomics for maximizing protein identifications, whereas few have been concerned with throughput and reproducibility. Here, we establish a rapid, robust and high reproducible DIA-based workflow for streamlined serum proteomic profiling from 1μL serum. The workflow doesn't need protein depletion and pre-fractionation, while still being able to detect disease-relevant proteins accurately. The workflow is promising in clinical application

  18. A Schistosoma haematobium-specific real-time PCR for diagnosis of urogenital schistosomiasis in serum samples of international travelers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan

    2013-01-01

    Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.

  19. Glyco-centric lectin magnetic bead array (LeMBA − proteomics dataset of human serum samples from healthy, Barrett׳s esophagus and esophageal adenocarcinoma individuals

    Directory of Open Access Journals (Sweden)

    Alok K. Shah

    2016-06-01

    Full Text Available This data article describes serum glycoprotein biomarker discovery and qualification datasets generated using lectin magnetic bead array (LeMBA – mass spectrometry techniques, “Serum glycoprotein biomarker discovery and qualification pipeline reveals novel diagnostic biomarker candidates for esophageal adenocarcinoma” [1]. Serum samples collected from healthy, metaplastic Barrett׳s esophagus (BE and esophageal adenocarcinoma (EAC individuals were profiled for glycoprotein subsets via differential lectin binding. The biomarker discovery proteomics dataset consisting of 20 individual lectin pull-downs for 29 serum samples with a spiked-in internal standard chicken ovalbumin protein has been deposited in the PRIDE partner repository of the ProteomeXchange Consortium with the data set identifier PRIDE: http://www.ebi.ac.uk/pride/archive/projects/PXD002442. Annotated MS/MS spectra for the peptide identifications can be viewed using MS-Viewer (〈http://prospector2.ucsf.edu/prospector/cgi-bin/msform.cgi?form=msviewer〉 using search key “jn7qafftux”. The qualification dataset contained 6-lectin pulldown-coupled multiple reaction monitoring-mass spectrometry (MRM-MS data for 41 protein candidates, from 60 serum samples. This dataset is available as a supplemental files with the original publication [1].

  20. Antinuclear, Cytoskeletal, Antineuronal Antibodies in the Serum Samples of Children with Tic Disorders and Obsessive Compulsive Disorders

    Directory of Open Access Journals (Sweden)

    Işık Görker

    2011-11-01

    Full Text Available streptococcus infections in the development of tic and obsessive compulsive disorders (OCD is controversial. The autoimmune hypothesis states that during infection, formation of autoantibodies leads to an autoimmune disorder, which in turn results in movement disorders, tic disorders and/or OCD. In order to test this hypothesis, we assayed these antibodies in children and adolescents diagnosed with tic disorders and/or OCD.Material and Methods: Children and adolescents who were diagnosed with either tic disorders or OCD according to DSM-IV criteria (n=28, were compared with healthy controls (n=15 having similar age and gender characteristics. Regardless of a streptococcus infection history, serum samples of all patients and controls underwent antinuclear, cytoskeletal, and antineuronal antibody assay using indirect immunofluorescence.Results: The rates of antinuclear antibody positivity were 21% and 20% in the patient and control groups respectively (p>0.05. Antineuronal antibody was positive in 2 (7% of 28 patients versus in 1 (6% of 15 controls (p>0.05.Conclusion: These results suggest that such antibodies may not be involved in the pathogenesis of tic disorders/OCD.

  1. Spectrophotometric determination of dopamine hydrochloride in pharmaceutical, banana, urine and serum samples by potassium ferricyanide-Fe(III).

    Science.gov (United States)

    Guo, Li; Zhang, Yan; Li, Quanmin

    2009-12-01

    In the present work, we developed a simple, sensitive and inexpensive method to determine dopamine hydrochloride using potassium ferricyanide-Fe(III) by spectrophotometry. The results show that Fe(III) is deoxidized to Fe(II) by dopamine hydrochloride at pH 4.0, and then Fe(II) reacts with potassium ferricyanide to form a soluble prussian blue (KFe(III)[Fe(II)(CN)6]). The absorbance of this product was monitored over time using a spectrophotometer at an absorption maximum of 735 nm, and the amount of dopamine hydrochloride could be calculated based on the absorbance. A good linear relationship of the concentration of dopamine hydrochloride versus absorbance was observed, and a linear regression equation of A = 0.022 + 0.16921C (microg mL(-1)) was obtained. Moreover, the apparent molar absorption coefficient for the indirect determination of dopamine hydrochloride was 3.2 x 10(4) L mol(-1) cm(-1). This described method has been used to determine dopamine hydrochloride in pharmaceutical, banana, urine and serum samples with satisfactory results.

  2. Detection and serotyping of dengue virus in serum samples by multiplex reverse transcriptase PCR-ligase detection reaction assay.

    Science.gov (United States)

    Das, S; Pingle, M R; Muñoz-Jordán, J; Rundell, M S; Rondini, S; Granger, K; Chang, G-J J; Kelly, E; Spier, E G; Larone, D; Spitzer, E; Barany, F; Golightly, L M

    2008-10-01

    The detection and successful typing of dengue virus (DENV) from patients with suspected dengue fever is important both for the diagnosis of the disease and for the implementation of epidemiologic control measures. A technique for the multiplex detection and typing of DENV serotypes 1 to 4 (DENV-1 to DENV-4) from clinical samples by PCR-ligase detection reaction (LDR) has been developed. A serotype-specific PCR amplifies the regions of genes C and E simultaneously. The two amplicons are targeted in a multiplex LDR, and the resultant fluorescently labeled ligation products are detected on a universal array. The assay was optimized using 38 DENV strains and was evaluated with 350 archived acute-phase serum samples. The sensitivity of the assay was 98.7%, and its specificity was 98.4%, relative to the results of real-time PCR. The detection threshold was 0.017 PFU for DENV-1, 0.004 PFU for DENV-2, 0.8 PFU for DENV-3, and 0.7 PFU for DENV-4. The assay is specific; it does not cross-react with the other flaviviruses tested (West Nile virus, St. Louis encephalitis virus, Japanese encephalitis virus, Kunjin virus, Murray Valley virus, Powassan virus, and yellow fever virus). All but 1 of 26 genotypic variants of DENV serotypes in a global DENV panel from different geographic regions were successfully identified. The PCR-LDR assay is a rapid, sensitive, specific, and high-throughput technique for the simultaneous detection of all four serotypes of DENV.

  3. Serum sample levels of bromine, iron, scandium and zinc in preschool children of Atayal and Bunun aborigines living in central Taiwan

    International Nuclear Information System (INIS)

    Chien-Yi Chen; Ding-Bang Lin; Yuan-Yaw Wei

    2006-01-01

    This study determined bromine, iron, scandium and zinc serum levels in Taiwanese aboriginal preschool children living in remote mountainous areas to increase the understanding of the social, cultural, nutrient and ethnic background of the Taiwanese children. Seventy-three serum samples were taken from two ethnic groups of preschool children, Atayal aborigines (AAPC) and Bunun aborigines (BAPC). Sera of these children were freeze dried. Trace elements in sera were identified by instrumental neutron activation analysis (INAA). The accuracy and precision of INAA was evaluated using certified reference materials: Tomato Leaves (NIST-SRM 1570a) and Lichen (IAEA-336). Statistical analysis identified several different patterns for ethnic groups, gender and age via the two-tailed Student's t-test. Analytical results showed that the ranges of Br, Fe, Sc and Zn in sera were somewhat wide. The Zn serum levels (p < 0.05) and Br serum levels (p < 0.01) in the AAPC were significantly lower than those in the BAPC. However, there were no significant differences in Fe or Sc serum levels between the two groups. Analytical results were compared to published data for different counties. This study is the first investigating trace elements in Taiwanese aborigines and can be used to establish a much-needed serum element database. (author)

  4. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  5. Ultratrace analysis of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in human serum and cerebrospinal fluid (CSF) samples

    Energy Technology Data Exchange (ETDEWEB)

    Takasuga, T.; Senthilkumar, K.; Watanabe, K.; Takemori, H. [Shimadzu Techno Research, Inc., Kyoto (Japan); Shoda, T. [Ehime Univ. Medical Research Center, Matsuyama (Japan); Kuroda, Y. [Tokyo Metropolitan Inst. for Neuroscience, Tokyo (Japan)

    2004-09-15

    In the present study, we established pretreatment and high sensitivity analytical method of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in serum and cerebrospinal fluid (CSF) of humans for the first time. Analyzing serum and CSF samples from humans found unique because PCBs behavior and metabolism could be discerned. Furthermore, so far studies reported concentrations of OH-PCBs in wildlife samples obtained by HRGC-LRMS or GC-ECD data. In this study, we established cleanup and analytical methods by high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS) using 1 mL of sample. Mainly, total PCBs and OH-PCBs in the CSF were extracted by specialized developed method. Using this method, PCBs and OH-PCBs could be determined swiftly. Based on this method, major OH-PCB congeners were detected from human, serum, CSF, control serum and Rhesus monkey plasma. Present methodology developed based on the isotope dilution technique using OH-PCBs standard and thus we suggest the present methodology could apply for ultra trace analysis of OHPCBs as well as total PCBs in human samples.

  6. Variation of calcium, copper and iron levels in serum, bile and stone samples of patients having different types of gallstone: A comparative study.

    Science.gov (United States)

    Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma

    2017-08-01

    Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (p0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an important factor for the formation of different types of

  7. Radioimmunologic determination of alphafetoproteins concentration in blood serum samples and in the amniotic fluid in healthy pregnant women in the 2 trimester of pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Skalba, P; Krupa, B; Rozmus, M; Brudnik, K; Kokocinska, D; Rajs, M [Slaska Akademia Medyczna, Katowice (Poland)

    1980-01-01

    Radioimmunologic technique of double antibodies was used for the determination of alphafetoprotein (AFP) concentrations in blood serum samples from 223 healthy, pregnant women with single pregnancies and in amniotic fluid samples from 43 donors. The gestational age during samples collection was 10 to 25 weeks. The AFP preparation for the test was supplied by the International Agency of Cancer Research, anti-AFP antibodies produced by Behringwerke and personally produced rabbit antiglobulin antibodies. The results of the AFP determinations in the blood and amniotic fluid samples were presented in tables in form of medians. The serum AFP concentrations overranging the double medians value were met in 8.5%, overranging the triple medians - in 2.6%. Repeat determinations decreased the number of false positive results for about 50%. The results permit to issue a conclusion that the used technique is fully applicable for scan examinations in prenatal diagnosis of fetal nervous system malformations.

  8. Fabrication of an electrochemical nanoaptasensor based on AuNPs for ultrasensitive determination of cocaine in serum sample

    International Nuclear Information System (INIS)

    Roushani, Mahmoud; Shahdost-fard, Faezeh

    2016-01-01

    Herein we describe an ultrasensitive electrochemical nanoaptasensor for the detection of one of the most dangerous narcotic drugs available, cocaine. The nanoaptasensor was constructed by the covalent attachment of a 5′-NH 2 -3′-gold nanoparticles terminated aptamer on the surface of a glassy carbon electrode which was deposited with gold nanoparticles (AuNPs/GCE). It is worth noting that the interaction of the cysteamine stable self-assembled monolayer on the AuNPs/GCE surface and the covalent attachment of terephthalaldehyde via amide coupling with the amine groups in the cysteamine and aptamer, respectively, resulted in the covalent attachment of the aptamer to AuNPs/GCE. The presence of gold nanoparticles both on surface of the glassy carbon electrode and in the end of the aptamer, can provide advantages such as increase of active surface area, high acceleration of the electron transfer and improved electrochemical signal, respectively. The decrease in the peak current of [Fe(CN) 6 ] 3−/4− as the probe redox with increase of cocaine concentration, in differential pulse voltammetry as the measuring technique, from 5 pM up to 5 nM was linear and an unprecedented detection limit of 0.5 pM was yielded. Furthermore, the effect of some common analgesic drugs as the potential interferents were investigated and also, to evaluate practical application of the proposed nanoaptasensor human blood serum sample as a real sample was used. Simple preparation, low operation cost, speed and validity are the decisive factors of this method motivating its application to biosensing investigation. - Highlights: • An electrochemical nanoaptasensor for the detection of cocaine is presented. • An AuNPs terminated aptamer was covalent bonded on the surface of the AuNPs/GCE. • The presence of AuNPs has many advantages and improved electrochemical signal. • Two linear ranges from 5 pM up to 5 nM and an unprecedented LOD of 0.5 pM were yielded. • It will shed light on new

  9. Fabrication of an electrochemical nanoaptasensor based on AuNPs for ultrasensitive determination of cocaine in serum sample

    Energy Technology Data Exchange (ETDEWEB)

    Roushani, Mahmoud, E-mail: mahmoudroushani@yahoo.com; Shahdost-fard, Faezeh

    2016-04-01

    Herein we describe an ultrasensitive electrochemical nanoaptasensor for the detection of one of the most dangerous narcotic drugs available, cocaine. The nanoaptasensor was constructed by the covalent attachment of a 5′-NH{sub 2}-3′-gold nanoparticles terminated aptamer on the surface of a glassy carbon electrode which was deposited with gold nanoparticles (AuNPs/GCE). It is worth noting that the interaction of the cysteamine stable self-assembled monolayer on the AuNPs/GCE surface and the covalent attachment of terephthalaldehyde via amide coupling with the amine groups in the cysteamine and aptamer, respectively, resulted in the covalent attachment of the aptamer to AuNPs/GCE. The presence of gold nanoparticles both on surface of the glassy carbon electrode and in the end of the aptamer, can provide advantages such as increase of active surface area, high acceleration of the electron transfer and improved electrochemical signal, respectively. The decrease in the peak current of [Fe(CN){sub 6}]{sup 3−/4−} as the probe redox with increase of cocaine concentration, in differential pulse voltammetry as the measuring technique, from 5 pM up to 5 nM was linear and an unprecedented detection limit of 0.5 pM was yielded. Furthermore, the effect of some common analgesic drugs as the potential interferents were investigated and also, to evaluate practical application of the proposed nanoaptasensor human blood serum sample as a real sample was used. Simple preparation, low operation cost, speed and validity are the decisive factors of this method motivating its application to biosensing investigation. - Highlights: • An electrochemical nanoaptasensor for the detection of cocaine is presented. • An AuNPs terminated aptamer was covalent bonded on the surface of the AuNPs/GCE. • The presence of AuNPs has many advantages and improved electrochemical signal. • Two linear ranges from 5 pM up to 5 nM and an unprecedented LOD of 0.5 pM were yielded. • It will shed

  10. Simultaneous acquisition of 2D and 3D solid-state NMR experiments for sequential assignment of oriented membrane protein samples

    Energy Technology Data Exchange (ETDEWEB)

    Gopinath, T. [University of Minnesota, Department of Biochemistry, Molecular Biology, and Biophysics (United States); Mote, Kaustubh R. [University of Minnesota, Department of Chemistry (United States); Veglia, Gianluigi, E-mail: vegli001@umn.edu [University of Minnesota, Department of Biochemistry, Molecular Biology, and Biophysics (United States)

    2015-05-15

    We present a new method called DAISY (Dual Acquisition orIented ssNMR spectroScopY) for the simultaneous acquisition of 2D and 3D oriented solid-state NMR experiments for membrane proteins reconstituted in mechanically or magnetically aligned lipid bilayers. DAISY utilizes dual acquisition of sine and cosine dipolar or chemical shift coherences and long living {sup 15}N longitudinal polarization to obtain two multi-dimensional spectra, simultaneously. In these new experiments, the first acquisition gives the polarization inversion spin exchange at the magic angle (PISEMA) or heteronuclear correlation (HETCOR) spectra, the second acquisition gives PISEMA-mixing or HETCOR-mixing spectra, where the mixing element enables inter-residue correlations through {sup 15}N–{sup 15}N homonuclear polarization transfer. The analysis of the two 2D spectra (first and second acquisitions) enables one to distinguish {sup 15}N–{sup 15}N inter-residue correlations for sequential assignment of membrane proteins. DAISY can be implemented in 3D experiments that include the polarization inversion spin exchange at magic angle via I spin coherence (PISEMAI) sequence, as we show for the simultaneous acquisition of 3D PISEMAI–HETCOR and 3D PISEMAI–HETCOR-mixing experiments.

  11. Simultaneous acquisition of 2D and 3D solid-state NMR experiments for sequential assignment of oriented membrane protein samples.

    Science.gov (United States)

    Gopinath, T; Mote, Kaustubh R; Veglia, Gianluigi

    2015-05-01

    We present a new method called DAISY (Dual Acquisition orIented ssNMR spectroScopY) for the simultaneous acquisition of 2D and 3D oriented solid-state NMR experiments for membrane proteins reconstituted in mechanically or magnetically aligned lipid bilayers. DAISY utilizes dual acquisition of sine and cosine dipolar or chemical shift coherences and long living (15)N longitudinal polarization to obtain two multi-dimensional spectra, simultaneously. In these new experiments, the first acquisition gives the polarization inversion spin exchange at the magic angle (PISEMA) or heteronuclear correlation (HETCOR) spectra, the second acquisition gives PISEMA-mixing or HETCOR-mixing spectra, where the mixing element enables inter-residue correlations through (15)N-(15)N homonuclear polarization transfer. The analysis of the two 2D spectra (first and second acquisitions) enables one to distinguish (15)N-(15)N inter-residue correlations for sequential assignment of membrane proteins. DAISY can be implemented in 3D experiments that include the polarization inversion spin exchange at magic angle via I spin coherence (PISEMAI) sequence, as we show for the simultaneous acquisition of 3D PISEMAI-HETCOR and 3D PISEMAI-HETCOR-mixing experiments.

  12. A sequential logic circuit for coincidences randomly distributed in 'time' and 'duration', with selection and total sampling

    International Nuclear Information System (INIS)

    Carnet, Bernard; Delhumeau, Michel

    1971-06-01

    The principles of binary analysis applied to the investigation of sequential circuits were used to design a two way coincidence circuit whose input may be, random or periodic variables of constant or variable duration. The output signal strictly reproduces the characteristics of the input signal triggering the coincidence. A coincidence between input signals does not produce any output signal if one of the signals has already triggered the output signal. The characteristics of the output signal in relation to those of the input signal are: minimum time jitter, excellent duration reproducibility and maximum efficiency. Some rules are given for achieving these results. The symmetry, transitivity and non-transitivity characteristics of the edges on the primitive graph are analyzed and lead to some rules for positioning the states on a secondary graph. It is from this graph that the equations of the circuits can be calculated. The development of the circuit and its dynamic testing are discussed. For this testing, the functioning of the circuit is simulated by feeding into the input randomly generated signals

  13. Simultaneous acquisition of 2D and 3D solid-state NMR experiments for sequential assignment of oriented membrane protein samples

    International Nuclear Information System (INIS)

    Gopinath, T.; Mote, Kaustubh R.; Veglia, Gianluigi

    2015-01-01

    We present a new method called DAISY (Dual Acquisition orIented ssNMR spectroScopY) for the simultaneous acquisition of 2D and 3D oriented solid-state NMR experiments for membrane proteins reconstituted in mechanically or magnetically aligned lipid bilayers. DAISY utilizes dual acquisition of sine and cosine dipolar or chemical shift coherences and long living 15 N longitudinal polarization to obtain two multi-dimensional spectra, simultaneously. In these new experiments, the first acquisition gives the polarization inversion spin exchange at the magic angle (PISEMA) or heteronuclear correlation (HETCOR) spectra, the second acquisition gives PISEMA-mixing or HETCOR-mixing spectra, where the mixing element enables inter-residue correlations through 15 N– 15 N homonuclear polarization transfer. The analysis of the two 2D spectra (first and second acquisitions) enables one to distinguish 15 N– 15 N inter-residue correlations for sequential assignment of membrane proteins. DAISY can be implemented in 3D experiments that include the polarization inversion spin exchange at magic angle via I spin coherence (PISEMAI) sequence, as we show for the simultaneous acquisition of 3D PISEMAI–HETCOR and 3D PISEMAI–HETCOR-mixing experiments

  14. An evaluation of multiplex bead-based analysis of cytokines and soluble proteins in archived lithium heparin plasma, EDTA plasma and serum samples

    DEFF Research Database (Denmark)

    Brøndum, Line; Sørensen, Brita Singers; Eriksen, Jesper Grau

    2016-01-01

    -13, and VEGF, LH plasma levels vs. EDTA plasma: IL-2 and IL-4. CONCLUSION: Stored serum, LH plasma, and EDTA plasma from clinical trials can be used for analysis of circulating cytokines and proteins. Variations in measurements occur, but are within reasonable ranges. The optimal type of media...... in plasma and serum from 86 head and neck cancer patients and 33 controls were evaluated: EGFR, leptin, OPN, VEGFR-1, VEGFR-2, IL-2, IL-13, PDGF-bb, TNF, PAI-1, SDF-1a, IL-4, IL-6, IL-8, eotaxin, G-CSF, VEGF, GRO-a, and HGF. RESULTS: The correlation between measurements of the same samples analyzed...... on different dates was reasonable. However, samples run on different dates could exhibit different absolute values. The 75th percentile of the fold differences for samples run on different dates was 2.2. No significant difference was found between one and four freeze-thaw cycles (except for HGF...

  15. Evaluation of nested polymerase chain reaction for the early detection of Leptospira spp. DNA in serum samples from patients with leptospirosis.

    Science.gov (United States)

    Blanco, Roberta Morozetti; Romero, Eliete Caló

    2014-04-01

    The aim of this study was to analyse the nested polymerase chain reaction (nested PCR) in human serum samples of patients with clinical manifestations of leptospirosis. The cases of leptospirosis were defined by the microagglutination test (MAT). The samples were collected in 2010. Of 1042 serum samples collected from 521 patients, 28 (5.4%) were considered positive cases of leptospirosis, and 493 (94.6%) were negative. Twenty-three confirmed cases had no MAT-detectable antibodies in the acute sample (mean of 5.6 days after onset). Nested PCR was positive in 22/23 (95.7%) patients during the acute phase of the disease, with negative results by MAT. Nested PCR was negative in all convalescent serum samples with positive results by MAT. All negative cases of leptospirosis were negative by nested PCR. The nested PCR is an alternative diagnostic tool for early detection of leptospires in sera during the first 7 days of the disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Mercury in Environmental and Biological Samples Using Online Combustion with Sequential Atomic Absorption and Fluorescence Measurements: A Direct Comparison of Two Fundamental Techniques in Spectrometry

    Science.gov (United States)

    Cizdziel, James V.

    2011-01-01

    In this laboratory experiment, students quantitatively determine the concentration of an element (mercury) in an environmental or biological sample while comparing and contrasting the fundamental techniques of atomic absorption spectrometry (AAS) and atomic fluorescence spectrometry (AFS). A mercury analyzer based on sample combustion,…

  17. Tissue and serum samples of patients with papillary thyroid cancer with and without benign background demonstrate different altered expression of proteins

    Directory of Open Access Journals (Sweden)

    Mardiaty Iryani Abdullah

    2016-09-01

    Full Text Available Background Papillary thyroid cancer (PTC is mainly diagnosed using fine-needle aspiration biopsy. This most common form of well-differentiated thyroid cancer occurs with or without a background of benign thyroid goiter (BTG. Methods In the present study, a gel-based proteomics analysis was performed to analyse the expression of proteins in tissue and serum samples of PTC patients with (PTCb; n = 6 and without a history of BTG (PTCa; n = 8 relative to patients with BTG (n = 20. This was followed by confirmation of the levels of proteins which showed significant altered abundances of more than two-fold difference (p < 0.01 in the tissue and serum samples of the same subjects using ELISA. Results The data of our study showed that PTCa and PTCb distinguish themselves from BTG in the types of tissue and serum proteins of altered abundance. While higher levels of alpha-1 antitrypsin (A1AT and heat shock 70 kDa protein were associated with PTCa, lower levels of A1AT, protein disulfide isomerase and ubiquitin-conjugating enzyme E2 N seemed apparent in the PTCb. In case of the serum proteins, higher abundances of A1AT and alpha 1-beta glycoprotein were detected in PTCa, while PTCb was associated with enhanced apolipoprotein A-IV and alpha 2-HS glycoprotein (AHSG. The different altered expression of tissue and serum A1AT as well as serum AHSG between PTCa and PTCb patients were also validated by ELISA. Discussion The distinctive altered abundances of the tissue and serum proteins form preliminary indications that PTCa and PTCb are two distinct cancers of the thyroid that are etiologically and mechanistically different although it is currently not possible to rule out that they may also be due other reasons such as the different stages of the malignant disease. These proteins stand to have a potential use as tissue or serum biomarkers to discriminate the three different thyroid neoplasms although this requires further validation in clinically

  18. A minimax procedure in the context of sequential mastery testing

    NARCIS (Netherlands)

    Vos, Hendrik J.

    1999-01-01

    The purpose of this paper is to derive optimal rules for sequential mastery tests. In a sequential mastery test, the decision is to classify a subject as a master or a nonmaster, or to continue sampling and administering another random test item. The framework of minimax sequential decision theory

  19. Applying the minimax principle to sequential mastery testing

    NARCIS (Netherlands)

    Vos, Hendrik J.

    2002-01-01

    The purpose of this paper is to derive optimal rules for sequential mastery tests. In a sequential mastery test, the decision is to classify a subject as a master, a nonmaster, or to continue sampling and administering another random item. The framework of minimax sequential decision theory (minimum

  20. Analysis of ethyl glucuronide in human serum by capillary electrophoresis with sample self-stacking and indirect detection

    Czech Academy of Sciences Publication Activity Database

    Křivánková, Ludmila; Caslavska, J.; Malášková, Hana; Gebauer, Petr; Thormann, W.

    2005-01-01

    Roč. 1081, č. 1 (2005), s. 2-8 ISSN 0021-9673 R&D Projects: GA AV ČR IAA4031401 Institutional research plan: CEZ:AV0Z40310501 Keywords : ethyl glucuronide * capillary electrophoresis * serum Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.096, year: 2005

  1. Reliability of Serum Metabolites over a Two-Year Period: A Targeted Metabolomic Approach in Fasting and Non-Fasting Samples from EPIC

    Science.gov (United States)

    Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro

    2015-01-01

    Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were fasting samples, the median ICC was 0.54. ICC values were fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920

  2. Simultaneous UHPLC-UV analysis of hydroxychloroquine, minocycline and doxycycline from serum samples for the therapeutic drug monitoring of Q fever and Whipple's disease.

    Science.gov (United States)

    Armstrong, Nicholas; Richez, Magali; Raoult, Didier; Chabriere, Eric

    2017-08-15

    A fast UHPLC-UV method was developed for the simultaneous analysis of Hydroxychloroquine, Minocycline and Doxycycline drugs from 100μL of human serum samples. Serum samples were extracted by liquid-liquid extraction and injected into a phenyl hexyl reverse phase column. Compounds were separated using a mobile phase linear gradient and monitored by UV detection at 343nm. Chloroquine and Oxytetracycline were used as internal standards. Lower and upper limits of quantifications, as well as the other levels of calibration, were validated with acceptable accuracy (<15% deviation) and precision (<15% coefficient of variation) according to the European Medicines Agency guidelines. This new method enables cost and time reduction and was considered suitable for the clinical laboratory. It is the first published assay for the therapeutic drug monitoring of patients diagnosed with Q fever or Whipple's disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Depleting high-abundant and enriching low-abundant proteins in human serum: An evaluation of sample preparation methods using magnetic nanoparticle, chemical depletion and immunoaffinity techniques.

    Science.gov (United States)

    de Jesus, Jemmyson Romário; da Silva Fernandes, Rafael; de Souza Pessôa, Gustavo; Raimundo, Ivo Milton; Arruda, Marco Aurélio Zezzi

    2017-08-01

    The efficiency of three different depletion methods to remove the most abundant proteins, enriching those human serum proteins with low abundance is checked to make more efficient the search and discovery of biomarkers. These methods utilize magnetic nanoparticles (MNPs), chemical reagents (sequential application of dithiothreitol and acetonitrile, DTT/ACN), and commercial apparatus based on immunoaffinity (ProteoMiner, PM). The comparison between methods shows significant removal of abundant protein, remaining in the supernatant at concentrations of 4.6±0.2, 3.6±0.1, and 3.3±0.2µgµL -1 (n=3) for MNPs, DTT/ACN and PM respectively, from a total protein content of 54µgµL -1 . Using GeLC-MS/MS analysis, MNPs depletion shows good efficiency in removing high molecular weight proteins (>80kDa). Due to the synergic effect between the reagents DTT and ACN, DTT/ACN-based depletion offers good performance in the depletion of thiol-rich proteins, such as albumin and transferrin (DTT action), as well as of high molecular weight proteins (ACN action). Furthermore, PM equalization confirms its efficiency in concentrating low-abundant proteins, decreasing the dynamic range of protein levels in human serum. Direct comparison between the treatments reveals 72 proteins identified when using MNP depletion (43 of them exclusively by this method), but only 20 proteins using DTT/ACN (seven exclusively by this method). Additionally, after PM treatment 30 proteins were identified, seven exclusively by this method. Thus, MNPs and DTT/ACN depletion can be simple, quick, cheap, and robust alternatives for immunochemistry-based protein depletion, providing a potential strategy in the search for disease biomarkers. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Prevalence of parvovirus B19 and parvovirus V9 DNA and antibodies in paired bone marrow and serum samples from healthy individuals.

    Science.gov (United States)

    Heegaard, Erik D; Petersen, Bodil Laub; Heilmann, Carsten J; Hornsleth, Allan

    2002-03-01

    Parvovirus B19 (hereafter referred to as B19) exhibits a marked tropism to human bone marrow (BM), and infection may lead to erythema infectiosum, arthropathy, hydrops fetalis, and various hematologic disorders. Recently, a distinct parvovirus isolate termed V9 with an unknown clinical spectrum was discovered. In contrast to the many studies of B19 serology and viremia, valid information on the frequency of B19 or V9 DNA in the BM of healthy individuals is limited. To develop a reference value, paired BM and serum samples from healthy subjects were tested for the presence of B19 and V9 DNA and specific antibodies. Immunoglobulin M (IgM) was not found in any of the serum samples. The prevalence of IgG showed a gradual and steady increase from 37% in children aged 1 to 5 years to 87% in people aged >50 years. When 190 well-characterized subjects were examined, B19 DNA was detected in the BM of 4 individuals (2.1%; 95% confidence interval, 0.58 to 5.3%) while none of the paired serum samples showed evidence of circulating viral DNA. V9 DNA was not found in any of the BM or serum samples. The finding of B19 DNA probably indicated a primary infection in one 7-year-old individual and reinfection or reactivation of persistent infection in the remaining three persons, aged 47 to 58 years. Serving as a benchmark for future studies, these findings are useful when interpreting epidemiologic data, performing BM transplantation, or considering clinical implications of parvovirus infection.

  5. Random sequential adsorption of cubes

    Science.gov (United States)

    Cieśla, Michał; Kubala, Piotr

    2018-01-01

    Random packings built of cubes are studied numerically using a random sequential adsorption algorithm. To compare the obtained results with previous reports, three different models of cube orientation sampling were used. Also, three different cube-cube intersection algorithms were tested to find the most efficient one. The study focuses on the mean saturated packing fraction as well as kinetics of packing growth. Microstructural properties of packings were analyzed using density autocorrelation function.

  6. Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2011-01-01

    size effect upon the separation efficiency revealed that small-sized (2 mL) columns sufficed to handle up to 50 g of environmental soil samples. Under the optimum conditions, chemical yields of plutonium exceeded 90% and the decontamination factors for uranium, thorium and lead ranged from 103 to 104....... The determination of plutonium isotopes in three standard/certified reference materials (IAEA-375 soil, IAEA-135 sediment and NIST-4359 seaweed) and two reference samples (Irish Sea sediment and Danish soil) revealed a good agreement with reference/certified values. The SI column-separation method...

  7. Serum insulin like growth factor-1 is associated with working memory, executive function and selective attention in a sample of healthy, fit older adults.

    Science.gov (United States)

    Bellar, D; Glickman, E L; Juvancic-Heltzel, J; Gunstad, J

    2011-03-31

    The present study examined the association between serum insulin like growth factor-1 (IGF-1) concentrations and cognitive function in a sample of healthy, fit older adults (age: 70.8±9.3 years, body mass index (BMI): 27.3±5.7). Participants reported to the laboratory and basic anthropometric data were collected, followed by a fasted blood draw to quantify serum IGF-1. Participants then underwent cognitive testing that included the Mini-Mental Status Exam (MMSE), Trail Making Test A and B, Ruff's 2 and 7 test of selective attention and Letter Number Sequencing. Results showed the participants were generally cognitively intact (MMSE 27.6±1.8). Significant partial correlations (controlled for age, gender and years of education) emerged between serum IGF-1 concentrations and the total (r=0.381, P=0.030) and longest trial (r=0.455, P=0.011) on Letter Number Sequencing. Similar partial correlations yielded significant relationships between serum IGF-1 and Ruff's Automatic Detection Errors (r=-0.495, P=0.006), Controlled Speed Errors (r=-0.598, P=0.002) and errors made on the Trial Making Test part B (r=-0.466, P=0.010). These findings suggest that fasting levels of serum IGF-1 are related to higher levels of cognitive performance in healthy older adults, including working memory, selective attention and executive function. Further work is needed to more clearly determine possible mechanisms. Copyright © 2011 IBRO. Published by Elsevier Ltd. All rights reserved.

  8. Molecular detection of Borrelia bissettii DNA in serum samples from patients in the Czech Republic with suspected borreliosis

    Czech Academy of Sciences Publication Activity Database

    Rudenko, Natalia; Golovchenko, Maryna; Růžek, Daniel; Piskunova, N.; Mallátová, N.; Grubhoffer, Libor

    2009-01-01

    Roč. 292, č. 2 (2009), s. 274-281 ISSN 0378-1097 R&D Projects: GA MŠk(CZ) LC06009; GA ČR GD524/03/H133; GA ČR(CZ) GA524/06/1479 Institutional research plan: CEZ:AV0Z60220518 Keywords : Borrelia bissettii in human serum * causative agent * co-infection * co-detection of different species * phylogenetic analysis Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 2.199, year: 2009

  9. Ultrasonic energy enhanced the efficiency of advance extraction methodology for enrichment of trace level of copper in serum samples of patients having neurological disorders.

    Science.gov (United States)

    Arain, Mariam S; Kazi, Tasneem G; Afridi, Hassan I; Ali, Jamshed; Akhtar, Asma

    2017-07-01

    An innovative dual dispersive ionic liquid based on ultrasound assisted microextraction (UDIL-μE), for the enrichment of trace levels of copper ion (Cu 2+ ), in serum (blood) of patients suffering from different neurological disorders. The enriched metal ions were subjected to flame atomic absorption spectrometry (FAAS). In the UDIL-μE method, the extraction solvent, ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C 4 mim][PF 6 ], was dispersed into the aqueous samples using an ultrasonic bath. The(PAN) 1-(2-pyridylazo)-2-naphthol was used as ligand for the complexation of Cu ion in IL (as extracting solvent). The various variables such as sonication time, pH, concentration of complexing agent, time and rate of centrifugation, IL volume that affect the extraction process were optimized. The enhancement factor (EF) and detection limit (LOD) was found under favorable condition was 31 and 0.36μgL -1 , respectively. Reliability of the proposed method was checked by relative standard deviation (%RSD), which was found to be <5%. The accuracy of developed procedure was assured by using certified reference material (CRM) of blood serum. The developed procedure was applied successfully to the analysis of concentration of Cu ion in blood serum of different neurological disorders subjects and referents of same age group. It was observed that the levels of Cu ion was two folds higher in serum samples of neurological disorders patients as related to normal referents of same age group. Copyright © 2016. Published by Elsevier B.V.

  10. Lab-on-Valve Micro Sequential Injection: A Versatile Approach for Implementing Integrated Sample Pre-preparations and Executing (Bio)Chemical Assays

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    waste generation. Most recently, the socalled third generation of FIA has emerged, that is, the Lab-on-Valve (LOV) approach, the conceptual basis of which is to incorporate all the necessary unit operational manipulations required, and, when possible, even the detection device into a single small...... integrated microconduit, or “laboratory”, placed atop a selection valve. The lecture will detail the evolution of the three generations of FIA, emphasis being placed on the LOV approach. Proven itself as a versatile front end to a variety of detection techniques, its utility will be exemplified by a series...... of the renewable microcolumn concept. Despite their excellent analytical chemical capabilities, ETAAS as well as ICPMS often require that the samples are subjected to suitable pretreatment in order to obtain the necessary sensitivity and selectivity. Either in order to separate the analyte from potentially...

  11. Lab-on-Valve Micro Sequential Injection: A Versatile Approach for Implementing Integrated Sample Pre-preparations and Executing (Bio)Chemical Assays

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    waste generation. Most recently, the Lab-on-Valve (LOV) approach has emerged. Termed the third generation of FIA, the conceptual basis of the LOV is to incorporate all the necessary unit operational manipulations required in a chemical assay, and, when possible, even the detection device, into a single...... small integrated microconduit, or “laboratory”, placed atop a selection valve. In the lecture emphasis will be placed on the LOV approach. Proven itself as a versatile front end to a variety of detection techniques, its utility will be exemplified by various applications. Particular focus......-phase microcolumn concept utilising hydrophobic as well as hydrophilic bead materials. Although ETAAS and ICPMS both are characterised by excellent analytical chemical capabilities, they nevertheless often require that the samples be subjected to suitable pretreatment in order to obtain the necessary sensitivity...

  12. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning.

    Science.gov (United States)

    Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D

    2013-12-01

    Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, urine diglycolic acid (both OR > 999; exact p sample results were excluded and two from the same case were averaged, yielding

  13. Sequential charged particle reaction

    International Nuclear Information System (INIS)

    Hori, Jun-ichi; Ochiai, Kentaro; Sato, Satoshi; Yamauchi, Michinori; Nishitani, Takeo

    2004-01-01

    The effective cross sections for producing the sequential reaction products in F82H, pure vanadium and LiF with respect to the 14.9-MeV neutron were obtained and compared with the estimation ones. Since the sequential reactions depend on the secondary charged particles behavior, the effective cross sections are corresponding to the target nuclei and the material composition. The effective cross sections were also estimated by using the EAF-libraries and compared with the experimental ones. There were large discrepancies between estimated and experimental values. Additionally, we showed the contribution of the sequential reaction on the induced activity and dose rate in the boundary region with water. From the present study, it has been clarified that the sequential reactions are of great importance to evaluate the dose rates around the surface of cooling pipe and the activated corrosion products. (author)

  14. Anti-Taenia solium metacestode IgG antibodies in serum samples from inhabitants of a central-western region of Brazil

    Directory of Open Access Journals (Sweden)

    Oliveira Heliana B. de

    2006-01-01

    Full Text Available A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB. Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51. The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5% and 47-52 kDa (80%. The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001. In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.

  15. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  16. Total Effective Xenoestrogen Burden in Serum Samples and Risk for Breast Cancer in a Population-Based Multicase–Control Study in Spain

    Science.gov (United States)

    Pastor-Barriuso, Roberto; Fernández, Mariana F.; Castaño-Vinyals, Gemma; Whelan, Denis; Pérez-Gómez, Beatriz; Llorca, Javier; Villanueva, Cristina M.; Guevara, Marcela; Molina-Molina, José-Manuel; Artacho-Cordón, Francisco; Barriuso-Lapresa, Laura; Tusquets, Ignasi; Dierssen-Sotos, Trinidad; Aragonés, Nuria; Olea, Nicolás; Kogevinas, Manolis; Pollán, Marina

    2016-01-01

    Background: Most studies on endocrine-disrupting chemicals and breast cancer have focused on single compounds and have produced inconclusive findings. Objectives: We assessed the combined estrogenic effects of mixtures of xenoestrogens in serum and their relationship to breast cancer risk. Methods: A total of 186 incident pretreatment breast cancer cases and 196 frequency-matched controls were randomly sampled from a large population-based multicase–control study in Spain. The total effective xenoestrogen burden attributable to organohalogenated xenoestrogens (TEXB-α) and endogenous hormones and more polar xenoestrogens (TEXB-β) was determined in serum samples using high-performance liquid chromatography and E-Screen bioassay. Odds ratios for breast cancer comparing tertiles of serum TEXB-α and TEXB-β were estimated using logistic models, and smooth risk trends were obtained using spline models. Results: Cases had higher geometric mean TEXB-α and TEXB-β levels (8.32 and 9.94 Eeq pM/mL, respectively) than controls (2.99 and 5.96 Eeq pM/mL, respectively). The fully adjusted odds ratios for breast cancer (95% confidence intervals) comparing the second and third tertiles of TEXB-α with the first tertile were 1.77 (0.76, 4.10) and 3.45 (1.50, 7.97), respectively, and those for TEXB-β were 2.35 (1.10, 5.03) and 4.01 (1.88, 8.56), respectively. A steady increase in risk was evident across all detected TEXB-α levels and a sigmoidal trend was observed for TEXB-β. Individual xenoestrogens showed weak and opposing associations with breast cancer risk. Conclusions: This is the first study to show a strong positive association between serum total xenoestrogen burden and breast cancer risk, highlighting the importance of evaluating xenoestrogen mixtures, rather than single compounds, when studying hormone-related cancers. Citation: Pastor-Barriuso R, Fernández MF, Castaño-Vinyals G, Whelan D, Pérez-Gómez B, Llorca J, Villanueva CM, Guevara M, Molina-Molina JM

  17. [Cultivation of a permanent fish cell line in serum-free media special experiences with a cytotoxicity test for waste water samples

    Science.gov (United States)

    Kohlpoth, Martin; Rusche, Brigitte

    1997-01-01

    The use of fetal calf serum (FCS) as standard medium additive for the cell cultivation must be regarded critically from the point of view of animal welfare as well as for scientific reasons and makes it necessary to look for alternatives. In the last years an in vitro cytotoxicity assay for the testing of industrial waste waters with the permanent fish cell line RTG-2 was established and pre-validated as an alternative to the fish test with the golden orfe. The application of FCS is also a special problem with regard to the testing of waste waters in a cytotoxicity test so that FCS-alternatives were tested. The RTG-2 cells were successfully adapted to the two solvents Basal Medium Supplement (BMS) and Ultroser-G (U-G) that are used to replace serum. The characterisation of these adapted cell lines showed no significant differences in growth rate, adhesion rate, viability and sensitivity to chemicals in comparison to the original RTG-2 cells. On the determination of the cytotoxicity of industrial waste waters the RTG-2 cells adapted to the BMS medium indicated a clearly higher toxicity of the waste water samples than the original RTG-2 cells. This result confirms the thesis that serum components react with waste water elements and thus change the bio-availability of toxic compounds.

  18. A new dispersive liquid-liquid microextraction using ionic liquid based microemulsion coupled with cloud point extraction for determination of copper in serum and water samples.

    Science.gov (United States)

    Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem

    2016-04-01

    A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Serum iron test

    Science.gov (United States)

    Fe+2; Ferric ion; Fe++; Ferrous ion; Iron - serum; Anemia - serum iron; Hemochromatosis - serum iron ... A blood sample is needed. Iron levels are highest in the morning. Your health care provider will likely have you do this test in the morning.

  20. [Trend of the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Retrospective analysis of serum samples of the years 2006-2015].

    Science.gov (United States)

    Müller, A; Freude, B

    2016-01-01

    An optimal selenium supply of cattle is essential, because an insufficiency can lead to health disorders and reduced performance. The aim of the study was to retrospectively evaluate the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Serum samples from 45  068 cattle with unknown clinical status originating from countries all across Europe, which had been sent by veterinarians to the IDEXX Laboratory Ludwigsburg, Germany, between January 1st, 2006 and June 30th, 2015, were routinely analyzed for the selenium concentration by means of Inductively Coupled Plasma Mass Spectrometry. A total of 40  949 samples (30  462 from Germany, 4004 from Austria, 3232 from Switzerland, 3251 from Denmark) were included in the evaluation. Results were categorized as follows: 50-150 µg/l: sufficient supply,  150 µg/l: supply too high. During the observation period, a generalized trend towards a decreasing selenium supply was clear. Denmark showed the best selenium supply (77.4% of samples indicating a sufficient supply); however, even in this country a tendency towards a deterioration was seen. A very poor situation with a strongly decreasing selenium supply was observed in Austria, followed by Germany (38% and 30% of samples, respectively, indicating an undersupply). For Switzerland, a constantly poor selenium supply was found (49% of samples indicating an undersupply). Due to the ongoing trend of a selenium undersupply in cattle herds, it is recommended to control the serum selenium concentration annually and supplement this trace element via mineral food when necessary.

  1. An optical sensor for the determination of digoxin in serum samples based on a molecularly imprinted polymer membrane

    International Nuclear Information System (INIS)

    Paniagua Gonzalez, Gema; Fernandez Hernando, Pilar; Durand Alegria, J. S.

    2009-01-01

    This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 x 10 -3 mg L -1 . The detection limit was 3.17 x 10 -5 mg L -1 . Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 x 10 -3 mg L -1 digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.

  2. An optical sensor for the determination of digoxin in serum samples based on a molecularly imprinted polymer membrane

    Energy Technology Data Exchange (ETDEWEB)

    Paniagua Gonzalez, Gema [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain); Fernandez Hernando, Pilar, E-mail: pfhernando@ccia.uned.es [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain); Durand Alegria, J. S. [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain)

    2009-04-13

    This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 x 10{sup -3} mg L{sup -1}. The detection limit was 3.17 x 10{sup -5} mg L{sup -1}. Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 x 10{sup -3} mg L{sup -1} digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.

  3. Serial monitoring of Mucorales DNA load in serum samples of a patient with disseminated mucormycosis after allogeneic bone marrow transplantation.

    Science.gov (United States)

    Shigemura, Tomonari; Nakazawa, Yozo; Matsuda, Kazuyuki; Sano, Kenji; Yaguchi, Takashi; Motobayashi, Mitsuo; Saito, Shoji; Noda, Shunsuke; Kobayashi, Norimoto; Agematsu, Kazunaga; Honda, Takayuki; Koike, Kenichi

    2014-08-01

    Mucormycosis is a fatal complication in immunocompromised patients, and is additionally difficult to diagnose due to the lack of useful serum biomarkers. Using a quantitative PCR approach, we retrospectively analyzed Mucorales DNA load in sera collected serially from a 3-year-old patient with chronic granulomatous disease, who died of multi-organ failure probably due to dissemination of Rhizomucor pusillus, which was detected from necropsy specimens. Mucorales DNA load was below the detection limit on days 9, 2, and 4 after unrelated bone marrow transplantation. Rhizomucor DNA was first detected on day 14 (1.6 × 10(3) copies/mL), and subsequently fluctuated between 1.3 × 10(3) and 37.2 × 10(3) copies/mL until day 43. Rhizomucor achieved a peak value of 940.0 × 10(3) copies/mL on day 48 the day before death. The detection or fluctuation of Rhizomucor DNA appeared to be associated with corticosteroid dosages or C-reactive protein levels. This specific, noninvasive, and highly quantitative assay may be useful for the early diagnosis of mucormycosis and prediction of disease progression.

  4. A competitive immunoassay for ultrasensitive detection of Hg"2"+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg"2"+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg"2"+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg"2"+. The ICT was able to directly detect Hg"2"+ without complexing due to the specific recognition of the mAb with Hg"2"+. The IC_5_0 and limit of detection (LOD) of the assay for Hg"2"+ detection were 0.12 ng mL"−"1 and 0.45 pg mL"−"1, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg"2"+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg"2"+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg"2"+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg"2"+ without formation of Hg"2"+-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg"2"+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg"2"+ in water, human serum and urine samples.

  5. A competitive immunoassay for ultrasensitive detection of Hg{sup 2+} in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    She, Pei; Chu, Yanxin [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Liu, Chunwei; Guo, Xun [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Zhao, Kang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Li, Jianguo, E-mail: lijgsd@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Du, Haijing; Zhang, Xiang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Wang, Hong [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Deng, Anping, E-mail: denganping@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China)

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg{sup 2+}. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg{sup 2+} and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg{sup 2+}. The ICT was able to directly detect Hg{sup 2+} without complexing due to the specific recognition of the mAb with Hg{sup 2+}. The IC{sub 50} and limit of detection (LOD) of the assay for Hg{sup 2+} detection were 0.12 ng mL{sup −1} and 0.45 pg mL{sup −1}, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg{sup 2+} were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg{sup 2+} in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg{sup 2+} in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg{sup 2+} without formation of Hg{sup 2+}-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg{sup 2+} detection. • The proposed ICT was applicable for the detection of trace amount of Hg{sup 2+} in water, human serum and urine samples.

  6. Matrix removal in state of the art sample preparation methods for serum by charged aerosol detection and metabolomics-based LC-MS.

    Science.gov (United States)

    Schimek, Denise; Francesconi, Kevin A; Mautner, Anton; Libiseller, Gunnar; Raml, Reingard; Magnes, Christoph

    2016-04-07

    Investigations into sample preparation procedures usually focus on analyte recovery with no information provided about the fate of other components of the sample (matrix). For many analyses, however, and particularly those using liquid chromatography-mass spectrometry (LC-MS), quantitative measurements are greatly influenced by sample matrix. Using the example of the drug amitriptyline and three of its metabolites in serum, we performed a comprehensive investigation of nine commonly used sample clean-up procedures in terms of their suitability for preparing serum samples. We were monitoring the undesired matrix compounds using a combination of charged aerosol detection (CAD), LC-CAD, and a metabolomics-based LC-MS/MS approach. In this way, we compared analyte recovery of protein precipitation-, liquid-liquid-, solid-phase- and hybrid solid-phase extraction methods. Although all methods provided acceptable recoveries, the highest recovery was obtained by protein precipitation with acetonitrile/formic acid (amitriptyline 113%, nortriptyline 92%, 10-hydroxyamitriptyline 89%, and amitriptyline N-oxide 96%). The quantification of matrix removal by LC-CAD showed that the solid phase extraction method (SPE) provided the lowest remaining matrix load (48-123 μg mL(-1)), which is a 10-40 fold better matrix clean-up than the precipitation- or hybrid solid phase extraction methods. The metabolomics profiles of eleven compound classes, comprising 70 matrix compounds showed the trends of compound class removal for each sample preparation strategy. The collective data set of analyte recovery, matrix removal and matrix compound profile was used to assess the effectiveness of each sample preparation method. The best performance in matrix clean-up and practical handling of small sample volumes was showed by the SPE techniques, particularly HLB SPE. CAD proved to be an effective tool for revealing the considerable differences between the sample preparation methods. This detector can

  7. Application of cloud point preconcentration and flame atomic absorption spectrometry for the determination of cadmium and zinc ions in urine, blood serum and water samples

    Directory of Open Access Journals (Sweden)

    Ardeshir Shokrollahi

    2013-01-01

    Full Text Available A simple, sensitive and selective cloud point extraction procedure is described for the preconcentration and atomic absorption spectrometric determination of Zn2+ and Cd2+ ions in water and biological samples, after complexation with 3,3',3",3'"-tetraindolyl (terephthaloyl dimethane (TTDM in basic medium, using Triton X-114 as nonionic surfactant. Detection limits of 3.0 and 2.0 µg L-1 and quantification limits 10.0 and 7.0 µg L-1were obtained for Zn2+ and Cd2+ ions, respectively. Relative standard deviation was 2.9 and 3.3, and enrichment factors 23.9 and 25.6, for Zn2+ and Cd2+ ions, respectively. The method enabled determination of low levels of Zn2+ and Cd2+ ions in urine, blood serum and water samples.

  8. Association between serum alkaline phosphatase and coronary artery calcification in a sample of primary cardiovascular prevention patients.

    Science.gov (United States)

    Panh, Loïc; Ruidavets, Jean Bernard; Rousseau, Hervé; Petermann, Antoine; Bongard, Vanina; Bérard, Emilie; Taraszkiewicz, Dorota; Lairez, Olivier; Galinier, Michel; Carrié, Didier; Ferrières, Jean

    2017-05-01

    A high level of serum alkaline phosphatase (ALP) is associated with an increased risk of mortality and myocardial infarction. ALP hydrolyses inorganic pyrophosphate, which is a strong inhibitor of calcium phosphate deposition. The aim of this study was to determine whether ALP is associated with the coronary artery calcium score (CACS). We examined the association of CACS, assessed by computed tomography scanning, and ALP, in 500 patients consecutively recruited, free of cardiovascular disease. The CACS were categorized into two groups: no calcification (CACS = 0) (n = 187) and with calcification (CACS>0) (n = 313). ALP activity was divided into three tertile groups: low ALP level (66 IU/L). The mean age was 60.9 ± 10.8 years, 49.6% of the patients were women. ALP ranged from 22 to 164 IU/L (mean 62.6 IU/L, SD 19.3). In univariate analysis, traditional cardiovascular risk factors, statin use (p = 0.001), and ALP (p = 0.001) were significantly associated with CACS. After adjusting for cardiovascular risk factors, only age (p = 0.001) and sex (p = 0.001) were independently associated with CACS. Compared to the tertile group with low levels of ALP, the intermediate tertile group [OR 2.11, 95% CI (1.12; 3.96), p = 0.02], as well as the high tertile group [OR 3.89, 95% CI (2.01; 7.54), p = 0.001)], was independently associated with CACS. In patients free of cardiovascular disease, high ALP levels are positively and independently associated with coronary artery calcification. The metabolic pathway of ALP and inorganic pyrophosphate could be a target for new therapies against vascular calcification. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Sequential stochastic optimization

    CERN Document Server

    Cairoli, Renzo

    1996-01-01

    Sequential Stochastic Optimization provides mathematicians and applied researchers with a well-developed framework in which stochastic optimization problems can be formulated and solved. Offering much material that is either new or has never before appeared in book form, it lucidly presents a unified theory of optimal stopping and optimal sequential control of stochastic processes. This book has been carefully organized so that little prior knowledge of the subject is assumed; its only prerequisites are a standard graduate course in probability theory and some familiarity with discrete-paramet

  10. A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

    Science.gov (United States)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg(2+). This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg(2+) and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg(2+). The ICT was able to directly detect Hg(2+) without complexing due to the specific recognition of the mAb with Hg(2+). The IC50 and limit of detection (LOD) of the assay for Hg(2+) detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg(2+) were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg(2+) in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg(2+) in environmental water samples and biological serum and urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  12. Comparison of serum pools and oral fluid samples for detection of porcine circovirus type 2 by quantitative real-time PCR in finisher pigs

    DEFF Research Database (Denmark)

    Nielsen, Gitte Blach; Nielsen, Jens Peter; Haugegaard, John

    2018-01-01

    Porcine circovirus type 2 (PCV2) diagnostics in live pigs often involves pooled serum and/or oral fluid samples for group-level determination of viral load by quantitative real-time polymerase chain reaction (qPCR). The purpose of the study was to compare the PCV2 viral load determined by q......PCR of paired samples at the pen level of pools of sera (SP) from 4 to 5 pigs and the collective oral fluid (OF) from around 30 pigs corresponding to one rope put in the same pen. Pigs in pens of 2 finishing herds were sampled by cross-sectional (Herd 1) and cross-sectional with follow-up (Herd 2) study designs....... In Herd 1, 50 sample pairs consisting of SP from 4 to 5 pigs and OF from around 23 pigs were collected. In Herd 2, 65 sample pairs consisting of 4 (SP) and around 30 (OF) pigs were collected 4 times at 3-week intervals. A higher proportion of PCV2-positive pens (86% vs. 80% and 100% vs. 91%) and higher...

  13. Collection and Characterization of Samples for Establishment of a Serum Repository for Lyme Disease Diagnostic Test Development and Evaluation

    Science.gov (United States)

    Molins, Claudia R.; Sexton, Christopher; Young, John W.; Ashton, Laura V.; Pappert, Ryan; Beard, Charles B.

    2014-01-01

    Serological assays and a two-tiered test algorithm are recommended for laboratory confirmation of Lyme disease. In the United States, the sensitivity of two-tiered testing using commercially available serology-based assays is dependent on the stage of infection and ranges from 30% in the early localized disease stage to near 100% in late-stage disease. Other variables, including subjectivity in reading Western blots, compliance with two-tiered recommendations, use of different first- and second-tier test combinations, and use of different test samples, all contribute to variation in two-tiered test performance. The availability and use of sample sets from well-characterized Lyme disease patients and controls are needed to better assess the performance of existing tests and for development of improved assays. To address this need, the Centers for Disease Control and Prevention and the National Institutes of Health prospectively collected sera from patients at all stages of Lyme disease, as well as healthy donors and patients with look-alike diseases. Patients and healthy controls were recruited using strict inclusion and exclusion criteria. Samples from all included patients were retrospectively characterized by two-tiered testing. The results from two-tiered testing corroborated the need for novel and improved diagnostics, particularly for laboratory diagnosis of earlier stages of infection. Furthermore, the two-tiered results provide a baseline with samples from well-characterized patients that can be used in comparing the sensitivity and specificity of novel diagnostics. Panels of sera and accompanying clinical and laboratory testing results are now available to Lyme disease serological test users and researchers developing novel tests. PMID:25122862

  14. Sequential memory: Binding dynamics

    Science.gov (United States)

    Afraimovich, Valentin; Gong, Xue; Rabinovich, Mikhail

    2015-10-01

    Temporal order memories are critical for everyday animal and human functioning. Experiments and our own experience show that the binding or association of various features of an event together and the maintaining of multimodality events in sequential order are the key components of any sequential memories—episodic, semantic, working, etc. We study a robustness of binding sequential dynamics based on our previously introduced model in the form of generalized Lotka-Volterra equations. In the phase space of the model, there exists a multi-dimensional binding heteroclinic network consisting of saddle equilibrium points and heteroclinic trajectories joining them. We prove here the robustness of the binding sequential dynamics, i.e., the feasibility phenomenon for coupled heteroclinic networks: for each collection of successive heteroclinic trajectories inside the unified networks, there is an open set of initial points such that the trajectory going through each of them follows the prescribed collection staying in a small neighborhood of it. We show also that the symbolic complexity function of the system restricted to this neighborhood is a polynomial of degree L - 1, where L is the number of modalities.

  15. Sequential Dependencies in Driving

    Science.gov (United States)

    Doshi, Anup; Tran, Cuong; Wilder, Matthew H.; Mozer, Michael C.; Trivedi, Mohan M.

    2012-01-01

    The effect of recent experience on current behavior has been studied extensively in simple laboratory tasks. We explore the nature of sequential effects in the more naturalistic setting of automobile driving. Driving is a safety-critical task in which delayed response times may have severe consequences. Using a realistic driving simulator, we find…

  16. Mining compressing sequential problems

    NARCIS (Netherlands)

    Hoang, T.L.; Mörchen, F.; Fradkin, D.; Calders, T.G.K.

    2012-01-01

    Compression based pattern mining has been successfully applied to many data mining tasks. We propose an approach based on the minimum description length principle to extract sequential patterns that compress a database of sequences well. We show that mining compressing patterns is NP-Hard and

  17. Excited state interaction between Hydrochlorothiazide and europium ion in PMMA polymer and its application as optical sensor for Hydrochlorothiazide in tablet and serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Attia, M.S., E-mail: Mohamed_sam@yahoo.com [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); Othman, A.M. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt); Youssef, A.O. [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); El-Raghi, E. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt)

    2012-08-15

    This paper reports on a facile technique combined with a simple, sensitive and selective spectrofluorimetric method for the determination of hydrochlorothiazide. In methanol, at pH 8.3 and {lambda}{sub ex}=340, hydrochlorothiazide can remarkably enhance the luminescence intensity of the Eu{sup 3+} ion doped in polymethylmethacrylate polymer (PMMA) matrix. This could be due to the energy transfer from hydrochlorothiazide to Eu{sup 3+} in the excited stated. At the optimized experimental conditions, the enhancement of the characteristic emission band (617 nm) of Eu{sup 3+} ion doped PMMA is directly proportional to the concentration of hydrochlorothiazide with a dynamic range of 5 Multiplication-Sign 10{sup -8}-1.0 Multiplication-Sign 10{sup -5} mol L{sup -1} and detection limit of 8.0 Multiplication-Sign 10{sup -9} mol L{sup -1}. Application of the suggested method was successfully applied to the determination of hydrochlorothiazide in pharmaceutical preparations and human serum samples, with high percentage of recovery, good accuracy and precision. - Highlights: Black-Right-Pointing-Pointer HCT was determined by europium sensitized by HCT in PMMA polymer. Black-Right-Pointing-Pointer Band at 617 nm of Eu{sup 3+} ion ({sup 5}D{sub 0}{yields}{sup 7}F{sub 2}) is sensitive to HCT concentration. Black-Right-Pointing-Pointer Recovery and R.S.D for tablets serum samples in proposed method were calculated. Black-Right-Pointing-Pointer Method is verified for HCT determination in real samples with no interferences.

  18. Magnetic immunoassay using CdSe/ZnS quantum dots as fluorescent probes to detect the level of DNA methyltransferase 1 in human serum sample

    Directory of Open Access Journals (Sweden)

    Yu F

    2018-01-01

    Full Text Available Fei Yu,1,* Ya-min Xiong,1,* Song-cheng Yu,1 Lei-liang He,1 Shan-shan Niu,1 Yu-ming Wu,1 Jie Liu,1 Ling-bo Qu,2 Li-e Liu,1 Yong-jun Wu1 1College of Public Health, 2College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou, Henan, People’s Republic of China *These authors contributed equally to this work Background: DNA methyltransferase 1 (DNMT1, a dominant enzyme responsible for the transfer of a methyl group from the universal methyl donor to the 5-position of cytosine residues in DNA, is essential for mammalian development and closely related to cancer and a variety of age-related chronic diseases. DNMT1 has become a useful biomarker in early disease diagnosis and a potential therapeutic target in cancer therapy and drug development. However, till now, most of the studies on DNA methyltransferase (MTase detection have focused on the prokaryote MTase and its activity.Methods: A magnetic fluorescence-linked immunosorbent assay (FLISA using CdSe/ZnS quantum dots as fluorescent probes was proposed for the rapid and sensitive detection of the DNMT1 level in this study. Key factors that affect the precision and accuracy of the determination of DNMT1 were optimized.Results: Under the optimal conditions, the limit of detection was 0.1 ng/mL, the linear range was 0.1–1,500 ng/mL, the recovery was 91.67%–106.50%, and the relative standard deviations of intra- and inter-assays were respectively 5.45%–11.29% and 7.03%–11.25%. The cross-reactivity rates with DNA methyltransferases 3a and 3b were only 4.0% and 9.4%, respectively. Furthermore, FLISA was successfully used to detect the levels of DNMT1 in human serum samples, and compared with commercial enzyme-linked immunosorbent assay (ELISA kits. The results revealed that there was a good correlation between FLISA and commercial ELISA kits (correlation coefficient r=0.866, p=0.001. The linear scope of FLISA was broader than ELISA, and the measurement time was much shorter

  19. Detection of Human Epididymis Protein 4 (HE4) in Human Serum Samples Using a Specific Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Zhou, Lijun; Lv, Zhiqiang; Shao, Jing; Xu, Ying; Luo, Xiaohong; Zhang, Yuming; Hu, Yang; Zhang, Wenji; Luo, Shuhong; Fang, Jianmin; Wang, Ying; Duan, Chaohui; Huang, Ruopan

    2016-09-01

    The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escherichia coli) and used to immunize mice in order to eventually generate hybridomas specific to HE4. The hybridoma supernatants were then screened, and four positive anti-HE4 cell lines were selected. These cell lines produce monoclonal antibodies against HE4 epitopes, as demonstrated in the Western blot as well as by direct enzyme-linked immunosorbent assay (ELISA). Using the developed antibodies, we successfully identified several good antibody pairs from the hybridomas, which allowed for the development of a sandwich ELISA to measure HE4 levels. By using the HE4 ELISA, we measured HE4 levels of 60 clinical human serum samples. Compared with the Food and Drug Administration (FDA) approved kit (Roche), our results showed a strong positive correlation to those of the FDA-approved kit. In summary, highly sensitive antibody pairs were screened against HE4, and a sandwich ELISA was developed as an accurate analytical tool for the detection of HE4 in human serum, which could be especially valuable for diagnosing ovarian carcinomas. © 2015 Wiley Periodicals, Inc.

  20. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Erkan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Ocsoy, Ismail [Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri 38039 (Turkey); Nanotechnology Research Center (ERNAM), Erciyes University, Kayseri 38039 (Turkey); Ozdemir, Nalan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Soylak, Mustafa, E-mail: soylak@erciyes.edu.tr [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey)

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L{sup −1} and 8.8 μg L{sup −1}, respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. - Highlights: • The synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers is reported. • The nanoflowers were utilized for solid phase microextraction of

  1. The effect of a non-denaturing detergent and a guanidinium-based inactivation agent on the viability of Ebola virus in mock clinical serum samples.

    Science.gov (United States)

    Burton, J E; Easterbrook, L; Pitman, J; Anderson, D; Roddy, S; Bailey, D; Vipond, R; Bruce, C B; Roberts, A D

    2017-12-01

    The 2014 Ebola outbreak in West Africa required the rapid testing of clinical material for the presence of potentially high titre Ebola virus (EBOV). Safe, fast and effective methods for the inactivation of such clinical samples are required so that rapid diagnostic tests including downstream analysis by RT-qPCR or nucleotide sequencing can be carried out. One of the most commonly used guanidinium - based denaturing agents, AVL (Qiagen) has been shown to fully inactivate EBOV once ethanol is added, however this is not compatible with the use of automated nucleic acid extraction systems. Additional inactivation agents need to be identified that can be used in automated systems. A candidate inactivation agent is Triton X-100, a non-denaturing detergent that is frequently used in clinical nucleic acid extraction procedures and has previously been used for inactivation of EBOV. In this study the effect of 0.1% and 1.0% Triton X-100 (final concentration 0.08% and 0.8% respectively) alone and in combination with AVL on the viability of EBOV (10 6 TCID 50 /ml) spiked into commercially available pooled negative human serum was tested. The presence of viable EBOV in the treated samples was assessed by carrying out three serial passages of the samples in Vero E6 cells (37°C, 5% CO 2 , 1 week for each passage). At the end of each passage the cells were observed for evidence of cytopathic effect and samples were taken for rRT-PCR analysis for the presence of EBOV RNA. Before cell culture cytotoxic components of AVL and Triton X-100 were removed from the samples using size exclusion spin column technology or a hydrophobic adsorbent resin. The results of this study showed that EBOV spiked into human serum was not fully inactivated when treated with either 0.1% (v/v) Triton X-100 for 10 mins or 1.0% (v/v) Triton X-100 for 20 mins (final concentrations 0.08% and 0.8% Triton X-100 respectively). AVL alone also did not consistently provide complete inactivation. Samples treated

  2. Develpoment of a procedure for the determination of chromium in samples of urine and serum by neutron activation analysis

    International Nuclear Information System (INIS)

    Buettner, I.; Hamm, V.; Knoechel, A.; Sen Gupta, R.

    1993-01-01

    Since the mid-fifties the possibility of a causal relationship between deficient chromium and insulin metabolism and the manifestation of certain varieties of diabetes mellitus has been presumed. The determination of the chromium status under pathophysiological conditions may be helpful for the study of this problem. For these purposes an analytical procedure as reference system was developed which allows the determination of chromium in biological matrices down to the concentration of 0.33 ng/ml. It is based on NAA and is used in the framework of a commonly used procedure based on GF-AAS. For its application blood and urine samples are freeze-dried and irradiated. After wet digestion with HNO 3 in a microwave combustion system chromium is separated for measurement from the matrix nuclides with the help of the ion-exchanger Cellex-P. THe individual steps of the procedure were evaluated by means of tracer experiments. (orig.)

  3. Develpoment of a procedure for the determination of chromium in samples of urine and serum by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Buettner, I [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry; Hamm, V [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry; Knoechel, A [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry; Sen Gupta, R [Hamburg Univ. (Germany). Inst. for Inorganic and Applied Chemistry

    1993-06-01

    Since the mid-fifties the possibility of a causal relationship between deficient chromium and insulin metabolism and the manifestation of certain varieties of diabetes mellitus has been presumed. The determination of the chromium status under pathophysiological conditions may be helpful for the study of this problem. For these purposes an analytical procedure as reference system was developed which allows the determination of chromium in biological matrices down to the concentration of 0.33 ng/ml. It is based on NAA and is used in the framework of a commonly used procedure based on GF-AAS. For its application blood and urine samples are freeze-dried and irradiated. After wet digestion with HNO[sub 3] in a microwave combustion system chromium is separated for measurement from the matrix nuclides with the help of the ion-exchanger Cellex-P. THe individual steps of the procedure were evaluated by means of tracer experiments. (orig.)

  4. Evaluation of pharmacokinetics and the stability of daptomycin in serum at various temperatures.

    Science.gov (United States)

    Ogami, Chika; Tsuji, Yasuhiro; Kasai, Hidefumi; Hiraki, Yoichi; Yamamoto, Yoshihiro; Matsunaga, Kazuhisa; Karube, Yoshiharu; To, Hideto

    2017-04-01

    Daptomycin exhibits concentration-dependent antibacterial activity. By monitoring daptomycin serum concentrations, clinicians may be able to predict the effectiveness of treatments for infections more accurately. However, it has been reported that daptomycin concentrations in plasma samples stored at -20°C decrease approximately 25% after 4 weeks. The aim of this study was to evaluate the stability of daptomycin in serum at various temperatures. Daptomycin serum samples were prepared and stored at different temperatures. The stability of daptomycin under various conditions was evaluated by sequential measurements of concentration. Although the loss of concentration of daptomycin in serum samples stored in freezers (-80°C and -20°C) was less than 10% after 168days (6 months), the concentrations in samples stored in a refrigerator (4°C) decreased by more than 70% over the same period. Furthermore, daptomycin concentrations in serum samples stored at close to body temperature (35°C, 37°C, and 39°C) decreased by more than 50% after only 24h. The results of the present study demonstrate that the measurement of serum concentrations of daptomycin needs to be performed rapidly. Furthermore, the degradation of daptomycin in serum may be involved in its elimination from the living body. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  5. Detection of Candida albicans Sap2 in cancer patient serum samples by an indirect competitive enzyme-linked immunosorbent assay for the diagnosis of candidiasis

    Directory of Open Access Journals (Sweden)

    Yicun Wang

    2013-01-01

    Full Text Available Background: The secreted aspartyl proteinases 2 (Sap2 of Candida albicans (C. albicans is a potential marker of candididasis. It is a virulence factor associated with adherence and tissue invasion. Aim: In order to detect Sap2 in clinical sera, we developed an indirect competitive enzyme-linked immunosorbent assay (ELISA. Materials and Methods: Polyclonal antibodies were produced for Sap2 by injecting Sap2 into a New Zealand White inbred rabbit. They could be used at a dilution exceeding 1:1200 in an indirect ELISA, and detected Sap2 concentration up to 1 ng/mL. Results: Of the 286 cancer serum samples tested, 16.8% were found as candidiasis. The test was simple and economical to perform and had a level of sensitivity for detection of low-titer positive sera; thus, it may be proven to be of value in epidemiological studies on candidiasis.

  6. Detection of Candida albicans Sap2 in cancer patient serum samples by an indirect competitive enzyme-linked immunosorbent assay for the diagnosis of candidiasis.

    Science.gov (United States)

    Wang, Yicun; Gao, Xiang; Zhi Gang, J U; Liu, Jingyuan; Dong, Shuai; Wang, Li

    2013-01-01

    The secreted aspartyl proteinases 2 (Sap2) of Candida albicans (C. albicans) is a potential marker of candididasis. It is a virulence factor associated with adherence and tissue invasion. In order to detect Sap2 in clinical sera, we developed an indirect competitive enzyme-linked immunosorbent assay (ELISA). Polyclonal antibodies were produced for Sap2 by injecting Sap2 into a New Zealand White inbred rabbit. They could be used at a dilution exceeding 1:1200 in an indirect ELISA, and detected Sap2 concentration up to 1 ng/mL. Of the 286 cancer serum samples tested, 16.8% were found as candidiasis. The test was simple and economical to perform and had a level of sensitivity for detection of low-titer positive sera; thus, it may be proven to be of value in epidemiological studies on candidiasis.

  7. A new supramolecular based liquid solid microextraction method for preconcentration and determination of trace bismuth in human blood serum and hair samples by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Kahe, Hadi; Chamsaz, Mahmoud

    2016-11-01

    A simple and reliable supramolecule-aggregated liquid solid microextraction method is described for preconcentration and determination of trace amounts of bismuth in water as well as human blood serum and hair samples. Catanionic microstructures of cetyltrimethylammonium bromide (CTAB) and sodium dodecyl sulfate (SDS) surfactants, dissolved in deionized water/propanol, are used as a green solvent to extract bismuth (III)-diethyldithiocarbamate complexes by dispersive microextraction methodology. The extracted solid phase is easily removed and dissolved in 50 μL propanol for subsequent measurement by electrothermal atomic absorption spectrometry (ET-AAS). The procedure benefits the merits of supramolecule aggregates' properties and dispersive microextraction technique using water as the main component of disperser solvent, leading to direct interaction with analyte. Phase separation behavior of extraction solvent and different parameters influencing the extraction efficiency of bismuth ion such as salt concentration, pH, centrifugation time, amount of chelating agent, SDS:CTAB mole ratio, and solvent amounts were thoroughly optimized. Under the optimal experimental conditions, the calibration curve was linear in the range of 0.3-6 μg L -1 Bi (III) with a limit of detection (LOD) of 0.16 μg L -1 (S/N = 3). The relative standard deviations (RSD) of determination were obtained to be 5.1 and 6.2 % for 1 and 3 μg L -1 of Bi (III), respectively. The developed method was successfully applied as a sensitive and accurate technique for determination of bismuth ion in human blood serum, hair samples, and a certified reference material.

  8. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis

    In this thesis we describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon codes with non-uniform profile. With this scheme decoding with good performance...... is possible as low as Eb/No=0.6 dB, which is about 1.7 dB below the signal-to-noise ratio that marks the cut-off rate for the convolutional code. This is possible since the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability...... of computational overflow. Analytical results for the probability that the first Reed-Solomon word is decoded after C computations are presented. This is supported by simulation results that are also extended to other parameters....

  9. Sequential Power-Dependence Theory

    NARCIS (Netherlands)

    Buskens, Vincent; Rijt, Arnout van de

    2008-01-01

    Existing methods for predicting resource divisions in laboratory exchange networks do not take into account the sequential nature of the experimental setting. We extend network exchange theory by considering sequential exchange. We prove that Sequential Power-Dependence Theory—unlike

  10. Modelling sequentially scored item responses

    NARCIS (Netherlands)

    Akkermans, W.

    2000-01-01

    The sequential model can be used to describe the variable resulting from a sequential scoring process. In this paper two more item response models are investigated with respect to their suitability for sequential scoring: the partial credit model and the graded response model. The investigation is

  11. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    Science.gov (United States)

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  12. Sequential Analysis: Hypothesis Testing and Changepoint Detection

    Science.gov (United States)

    2014-07-11

    maintains the flexibility of deciding sooner than the fixed sample size procedure at the price of some lower power [13, 514]. The sequential probability... markets , detection of signals with unknown arrival time in seismology, navigation, radar and sonar signal processing, speech segmentation, and the... skimming cruise missile can yield a significant increase in the probability of raid annihilation. Furthermore, usually detection systems are

  13. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis; Paaske, Erik

    1998-01-01

    We describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon (RS) codes with nonuniform profile. With this scheme decoding with good performance is possible as low...... as Eb/N0=0.6 dB, which is about 1.25 dB below the signal-to-noise ratio (SNR) that marks the cutoff rate for the full system. Accounting for about 0.45 dB due to the outer codes, sequential decoding takes place at about 1.7 dB below the SNR cutoff rate for the convolutional code. This is possible since...... the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability of computational overflow. Analytical results for the probability that the first RS word is decoded after C computations are presented. These results are supported...

  14. Rapid detection of cytomegalovirus in bronchoalveolar lavage fluid and serum samples by polymerase chain reaction: correlation of virus isolation and clinical outcome for patients with human immunodeficiency virus infection

    DEFF Research Database (Denmark)

    Hansen, K K; Vestbo, Jørgen; Benfield, T

    1997-01-01

    Bronchoalveolar lavage (BAL) fluids and serum samples from 153 patients with pulmonary symptoms who were infected with human immunodeficiency virus (HIV) and underwent BAL were examined for the presence of cytomegalovirus (CMV) by conventional culture and by polymerase chain reaction (PCR...... technique than conventional culture. Detection of CMV DNA in BAL fluid or serum predicted subsequent development of extrapulmonary CMV disease but not death for HIV-infected patients with pulmonary symptoms....

  15. Comparison of PRRSV Nucleic Acid and Antibody Detection in Pen-Based Oral Fluid and Individual Serum Samples in Three Different Age Categories of Post-Weaning Pigs from Endemically Infected Farms.

    Directory of Open Access Journals (Sweden)

    Nick De Regge

    Full Text Available Porcine reproductive and respiratory syndrome virus (PRRSV is the causative agent of an economically important disease in swine. Since it has been shown that PRRSV and PRRSV specific antibodies can be detected in oral fluid, many different aspects have been studied to show that oral fluid could be a worthy alternative diagnostic sample to serum for monitoring and surveillance of this disease. Thorough field evaluations are however missing to convincingly show its usefulness under representative field conditions.Pen-based oral fluid samples and serum samples from all individual pigs in the corresponding pens were collected from post-weaning pigs of three different age categories in eight endemically PRRSV infected farms and one PRRSV free farm in Belgium. All samples were tested by quantitative reverse transcription polymerase chain reaction (qRT-PCR and ELISA to detect PRRSV RNA and PRRSV specific antibodies, respectively.While the relative specificity of PRRSV detection by qRT-PCR in pen-based oral fluid compared to serum collected from individual pigs was high in all age categories (>90%, the relative sensitivity decreased with the age of the pigs (89, 93 and 10% in 8-12w, 16-20w and 24-28w old pigs, respectively. The latter correlated with a lower percentage of PRRSV positive pigs in serum/pen in the different age categories (55, 29 and 6%, respectively. Irrespective of the age category, pen-based oral fluid samples were always found PCR positive when at least 30% of the individual pigs were positive in serum. PRRSV specific antibody detection in oral fluid by ELISA showed a 100% relative sensitivity to detection in serum since oral fluid samples were always positive as soon as one pig in the pen was positive in serum. On the other hand, two false positive oral fluid samples in 11 pens without serum positive pigs were found, resulting in a relative specificity of 82%. Indications are however present that the oral fluid result indicated the

  16. Sequential decay of Reggeons

    International Nuclear Information System (INIS)

    Yoshida, Toshihiro

    1981-01-01

    Probabilities of meson production in the sequential decay of Reggeons, which are formed from the projectile and the target in the hadron-hadron to Reggeon-Reggeon processes, are investigated. It is assumed that pair creation of heavy quarks and simultaneous creation of two antiquark-quark pairs are negligible. The leading-order terms with respect to ratio of creation probabilities of anti s s to anti u u (anti d d) are calculated. The production cross sections in the target fragmentation region are given in terms of probabilities in the initial decay of the Reggeons and an effect of manyparticle production. (author)

  17. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples.

    Science.gov (United States)

    Yilmaz, Erkan; Ocsoy, Ismail; Ozdemir, Nalan; Soylak, Mustafa

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L(-)(1) and 8.8 μg L(-)(1), respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Magnetic solid phase extraction of gemfibrozil from human serum and pharmaceutical wastewater samples utilizing a β-cyclodextrin grafted graphene oxide-magnetite nano-hybrid.

    Science.gov (United States)

    Abdolmohammad-Zadeh, Hossein; Talleb, Zeynab

    2015-03-01

    A magnetic solid phase extraction method based on β-cyclodextrin (β-CD) grafted graphene oxide (GO)/magnetite (Fe3O4) nano-hybrid as an innovative adsorbent was developed for the separation and pre-concentration of gemfibrozil prior to its determination by spectrofluorometry. The as-prepared β-CD/GO/Fe3O4 nano-hybrid possesses the magnetism property of Fe3O4 nano-particles that makes it easily manipulated by an external magnetic field. On the other hand, the surface modification of GO by β-CD leads to selective separation of the target analyte from sample matrices. The structure and morphology of the synthesized adsorbent were characterized using powder X-ray diffraction, Fourier transform infrared spectroscopy, and field emission scanning electron microscopy. The experimental factors affecting the extraction/pre-concentration and determination of the analyte were investigated and optimized. Under the optimized experimental conditions, the calibration graph was linear in the range between 10 and 5000 pg mL(-1) with a correlation coefficient of 0.9989. The limit of detection and enrichment factor for gemfibrozil were 3 pg mL(-1) and 100, respectively. The maximum sorption capacity of the adsorbent for gemfibrozil was 49.8 mg g(-1). The method was successfully applied to monitoring gemfibrozil in human serum and pharmaceutical wastewaters samples with recoveries in the range of 96.0-104.0% for the spiked samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Synthetic Aperture Sequential Beamforming

    DEFF Research Database (Denmark)

    Kortbek, Jacob; Jensen, Jørgen Arendt; Gammelmark, Kim Løkke

    2008-01-01

    A synthetic aperture focusing (SAF) technique denoted Synthetic Aperture Sequential Beamforming (SASB) suitable for 2D and 3D imaging is presented. The technique differ from prior art of SAF in the sense that SAF is performed on pre-beamformed data contrary to channel data. The objective is to im......A synthetic aperture focusing (SAF) technique denoted Synthetic Aperture Sequential Beamforming (SASB) suitable for 2D and 3D imaging is presented. The technique differ from prior art of SAF in the sense that SAF is performed on pre-beamformed data contrary to channel data. The objective...... is to improve and obtain a more range independent lateral resolution compared to conventional dynamic receive focusing (DRF) without compromising frame rate. SASB is a two-stage procedure using two separate beamformers. First a set of Bmode image lines using a single focal point in both transmit and receive...... is stored. The second stage applies the focused image lines from the first stage as input data. The SASB method has been investigated using simulations in Field II and by off-line processing of data acquired with a commercial scanner. The performance of SASB with a static image object is compared with DRF...

  20. Does the time interval between antimüllerian hormone serum sampling and initiation of ovarian stimulation affect its predictive ability in in vitro fertilization-intracytoplasmic sperm injection cycles with a gonadotropin-releasing hormone antagonist?

    DEFF Research Database (Denmark)

    Polyzos, Nikolaos P; Nelson, Scott M; Stoop, Dominic

    2013-01-01

    To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response.......To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response....

  1. Estimation After a Group Sequential Trial.

    Science.gov (United States)

    Milanzi, Elasma; Molenberghs, Geert; Alonso, Ariel; Kenward, Michael G; Tsiatis, Anastasios A; Davidian, Marie; Verbeke, Geert

    2015-10-01

    Group sequential trials are one important instance of studies for which the sample size is not fixed a priori but rather takes one of a finite set of pre-specified values, dependent on the observed data. Much work has been devoted to the inferential consequences of this design feature. Molenberghs et al (2012) and Milanzi et al (2012) reviewed and extended the existing literature, focusing on a collection of seemingly disparate, but related, settings, namely completely random sample sizes, group sequential studies with deterministic and random stopping rules, incomplete data, and random cluster sizes. They showed that the ordinary sample average is a viable option for estimation following a group sequential trial, for a wide class of stopping rules and for random outcomes with a distribution in the exponential family. Their results are somewhat surprising in the sense that the sample average is not optimal, and further, there does not exist an optimal, or even, unbiased linear estimator. However, the sample average is asymptotically unbiased, both conditionally upon the observed sample size as well as marginalized over it. By exploiting ignorability they showed that the sample average is the conventional maximum likelihood estimator. They also showed that a conditional maximum likelihood estimator is finite sample unbiased, but is less efficient than the sample average and has the larger mean squared error. Asymptotically, the sample average and the conditional maximum likelihood estimator are equivalent. This previous work is restricted, however, to the situation in which the the random sample size can take only two values, N = n or N = 2 n . In this paper, we consider the more practically useful setting of sample sizes in a the finite set { n 1 , n 2 , …, n L }. It is shown that the sample average is then a justifiable estimator , in the sense that it follows from joint likelihood estimation, and it is consistent and asymptotically unbiased. We also show why

  2. Detection of Anti-Leptospira IgM Antibody in Serum Samples of Suspected Patients Visiting National Public Health Laboratory, Teku, Kathmandu

    Directory of Open Access Journals (Sweden)

    Krishna Prasad Dahal

    2016-01-01

    Full Text Available Leptospirosis is a globally distributed zoonosis with varied clinical outcomes and multiorgan involvement in humans. In this study conducted from July 2011 to December 2011, 178 serum samples from patients suspected of leptospirosis were tested by Panbio IgM ELISA at National Public Health Laboratory, Kathmandu, out of which 51 (28.65% were positive for anti-Leptospira IgM antibody. Leptospirosis was more common in people in their 2nd and 3rd decades of their life which together comprised 56.86% of the total positive cases. Most of those tested positive were farmers followed by students and housewives. Both animal contact and water contact seemed to play significant roles in disease transmission. Symptoms were vague with the most common being fever, headache, myalgia, abdominal pain, vomiting, jaundice, and diarrhoea. Life style heavily dominated by agronomical and farming activities in Nepal is conducive to leptospirosis transmission. Leptospirosis seems to be a significant public health problem in Nepal but is underestimated. In resource poor countries like Nepal where laboratories performing MAT or maintaining cultures are rarely available, serological test like ELISA could well depict the scenario of the disease prevalence.

  3. Hand-held optical sensor using denatured antibody coated electro-active polymer for ultra-trace detection of copper in blood serum and environmental samples.

    Science.gov (United States)

    Chandra, Sutapa; Dhawangale, Arvind; Mukherji, Soumyo

    2018-07-01

    An optimum copper concentration in environment is highly desired for all forms of life. We have developed an ultrasensitive copper sensor which functions from femto to micro molar concentration accurately (R 2 = 0.98). The sensor is based on denatured antibody immunoglobulin G (IgG), immobilized on polyaniline (PAni) which in turn is the coating on the core of an optical fiber. The sensing relies on changes in evanescent wave absorbance in the presence of the analyte. The sensor showed excellent selectivity towards Cu (II) ions over all other metal ions. The sensor was tested with lake and marine water samples to determine unknown concentrations of copper ions and the recovery results were within 90-115%, indicating reasonable accuracy. We further integrated the fiber-optic sensor with a miniaturized hand-held instrumentation platform to develop an accurate and field deployable device which can broadly be applicable to determine Cu (II) concentration in a wide range of systems - natural water bodies, soil as well as blood serum. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. [Detection of serum proteins in the patients of lung adenocarcinoma by the method of magnetic bead based sample fractionation and MALDI-TOF-MS].

    Science.gov (United States)

    Liu, Dan; Liu, Lun-Xu; Yuan, Quan; Li, Xiao-Liang; Huang, Na; Yang, Xiao-Dong

    2010-05-01

    To screen the serum proteins related to human lung adenocarcinoma using matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) technology. The blood samples were collected from 10 patients of lung adenocarcinoma before and one week after the surgery, while 10 healthy subjects were used as control. The differential protein expression between the two groups and the change of those proteins after surgery were studied by ClinProt magnetic bead enrichment and MALDI-TOF-MS. Six protein peaks were identified, 2 of them were highly expressed protein biomarkers with relative molecular weights of 2661, 2991, and increased after the surgery, 4 of them were lowly expressed protein biomarkers with relative molecular weights of 4091, 4210, 4644, 5336, which continuously decreased after the surgery. ClinProt magnetic bead enrichment and MALDI-TOF-MS is a quick, easy and sensitive method of proteomics. The differential expressed proteins may be the latent tumor marker of lung adenocarcinoma. The alteration of those proteins after surgery might be helpful to assess the therapeutic effect and prognosis.

  5. Sensitive and selective spectrophotometric assay of piroxicam in pure form, capsule and human blood serum samples via ion-pair complex formation

    Science.gov (United States)

    Alizadeh, Nina; Keyhanian, Fereshteh

    2014-09-01

    A simple, accurate and highly sensitive spectrophotometric method has been developed for the rapid determination of piroxicam (PX) in pure and pharmaceutical formulations. The proposed method involves formation of stable yellow colored ion-pair complexes of the amino derivative (basic nitrogen) of PX with three sulphonphthalein acid dyes namely; bromocresol green (BCG), bromothymol blue (BTB), bromophenol blue (BPB) in acidic medium. The colored species exhibited absorption maxima at 438, 429 and 432 nm with molar absorptivity values of 9.400 × 103, 1.218 × 103 and 1.02 × 104 L mol-1 cm-1 for PX-BCG, PX-BTB and PX-BPB complexes, respectively. The effect of optimum conditions via acidity, reagent concentration, time and solvent were studied. The reactions were extremely rapid at room temperature and the absorbance values remained constant for 48 h. Beer’s law was obeyed with a good correlation coefficient in the concentration ranges 1-100 μg mL-1 for BCG, BTB complexes and 1-95 μg mL-1 for BPB complex. The composition ratio of the ion-pair complexes were found to be 1:1 in all cases as established by Job’s method. No interference was observed from common additives and excipients which may be present in the pharmaceutical preparations. The proposed method was successfully applied for the determination of PX in capsule and human blood serum samples with good accuracy and precision.

  6. Oral pathology follow-up by means of micro-Raman spectroscopy on tissue and blood serum samples: an application of wavelet and multivariate data analysis

    Science.gov (United States)

    Delfino, I.; Camerlingo, C.; Zenone, F.; Perna, G.; Capozzi, V.; Cirillo, N.; Gaeta, G. M.; De Mol, E.; Lepore, M.

    2009-02-01

    Pemphigus vulgaris (PV) is a potentially fatal autoimmune disease that cause blistering of the skin and oral cavity. It is characterized by disruption of cell-cell adhesion within the suprabasal layers of epithelium, a phenomenon termed acantholysis Patients with PV develop IgG autoantibodies against normal constituents of the intercellular substance of keratinocytes. The mechanisms by which such autoantibodies induce blisters are not clearly understood. The qualitative analysis of such effects provides important clues in the search for a specific diagnosis, and the quantitative analysis of biochemical abnormalities is important in measuring the extent of the disease process, designing therapy and evaluating the efficacy of treatment. Improved diagnostic techniques could permit the recognition of more subtle forms of disease and reveal incipient lesions clinically unapparent, so that progression of potentially severe forms could be reversed with appropriate treatment. In this paper, we report the results of our micro-Raman spectroscopy study on tissue and blood serum samples from ill, recovered and under therapy PV patients. The complexity of the differences among their characteristic Raman spectra has required a specific strategy to obtain reliable information on the illness stage of the patients For this purpose, wavelet techniques and advanced multivariate analysis methods have been developed and applied to the experimental Raman spectra. Promising results have been obtained.

  7. Implementation of a SPR immunosensor for the simultaneous detection of the 22K and 20K hGH isoforms in human serum samples.

    Science.gov (United States)

    de Juan-Franco, Elena; Rodríguez-Frade, J M; Mellado, M; Lechuga, Laura M

    2013-09-30

    We have implemented a Surface Plasmon Resonance (SPR) immunosensor based on a sandwich assay for the simultaneous detection of the two main hGH isoforms, of 22 kDa (22K) and 20 kDa (20K). An oriented-antibody sensor surface specific for both hormone isoforms was assembled by using the biotin-streptavidin system. The immunosensor functionality was checked for the direct detection of the 22K hGH isoform in buffer, which gave high specificity and reproducibility (intra and inter-assay mean coefficients of variation of 8.23% and 9% respectively). The selective determination of the 22K and 20K hGH isoforms in human serum samples in a single assay was possible by using two specific anti-hGH monoclonal antibodies. The detection limit for both hormone isoforms was 0.9 ng mL(-1) and the mean coefficient of variation was below 7.2%. The excellent reproducibility and sensitivity obtained indicate the high performance of this immunosensor for implementing an anti-doping test. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Standardizing serum 25-hydroxyvitamin D data from four Nordic population samples using the Vitamin D Standardization Program protocols: Shedding new light on vitamin D status in Nordic individuals

    DEFF Research Database (Denmark)

    Cashman, Kevin D; Dowling, Kirsten G; Škrabáková, Zuzana

    2015-01-01

    for the European Union are of variable quality making it difficult to estimate the prevalence of vitamin D deficiency across member states. As a consequence of the widespread, method-related differences in measurements of serum 25(OH)D concentrations, the Vitamin D Standardization Program (VDSP) developed...... protocols for standardizing existing serum 25(OH)D data from national surveys around the world. The objective of the present work was to apply the VDSP protocols to existing serum 25(OH)D data from a Danish, a Norwegian, and a Finnish population-based health survey and from a Danish randomized controlled...

  9. Survey of serum concentrations of dioxins, furans, and coplanar polychlorinated biphenyls in a small non-random sample of U.S. residents

    Energy Technology Data Exchange (ETDEWEB)

    Grassman, J. [Brooklyn Coll. CUNY, Health and Nutrition Sciences, Brooklyn, New York, NY (United States); Patterson, D.G. Jr.; Needham, L.L. [National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States); Spencer, D.L.; Masten, S.A. [Environmental Toxicology Program, National Inst. of Environmental Health Sciences, Research Triangle Park, NC (United States)

    2004-09-15

    This cross sectional assessment of serum dioxin concentrations was conducted as part of a larger study to examine the relationship between dioxin exposure and gene expression in peripheral blood mononuclear cells. Recent reports indicate that environmental levels of dioxins have declined since the mid-1980's. Except for the recent National Health and Nutrition Examination Survey (NHANES), there has been little systematic surveillance of serum dioxins levels in the US general population. Here, we report the serum concentrations of 22 congeners of dioxins and dioxin-like compounds and their relationship with age, sex, smoking, and meat consumption.

  10. Multilevel sequential Monte Carlo samplers

    KAUST Repository

    Beskos, Alexandros; Jasra, Ajay; Law, Kody; Tempone, Raul; Zhou, Yan

    2016-01-01

    In this article we consider the approximation of expectations w.r.t. probability distributions associated to the solution of partial differential equations (PDEs); this scenario appears routinely in Bayesian inverse problems. In practice, one often has to solve the associated PDE numerically, using, for instance finite element methods which depend on the step-size level . hL. In addition, the expectation cannot be computed analytically and one often resorts to Monte Carlo methods. In the context of this problem, it is known that the introduction of the multilevel Monte Carlo (MLMC) method can reduce the amount of computational effort to estimate expectations, for a given level of error. This is achieved via a telescoping identity associated to a Monte Carlo approximation of a sequence of probability distributions with discretization levels . ∞>h0>h1⋯>hL. In many practical problems of interest, one cannot achieve an i.i.d. sampling of the associated sequence and a sequential Monte Carlo (SMC) version of the MLMC method is introduced to deal with this problem. It is shown that under appropriate assumptions, the attractive property of a reduction of the amount of computational effort to estimate expectations, for a given level of error, can be maintained within the SMC context. That is, relative to exact sampling and Monte Carlo for the distribution at the finest level . hL. The approach is numerically illustrated on a Bayesian inverse problem. © 2016 Elsevier B.V.

  11. Multilevel sequential Monte Carlo samplers

    KAUST Repository

    Beskos, Alexandros

    2016-08-29

    In this article we consider the approximation of expectations w.r.t. probability distributions associated to the solution of partial differential equations (PDEs); this scenario appears routinely in Bayesian inverse problems. In practice, one often has to solve the associated PDE numerically, using, for instance finite element methods which depend on the step-size level . hL. In addition, the expectation cannot be computed analytically and one often resorts to Monte Carlo methods. In the context of this problem, it is known that the introduction of the multilevel Monte Carlo (MLMC) method can reduce the amount of computational effort to estimate expectations, for a given level of error. This is achieved via a telescoping identity associated to a Monte Carlo approximation of a sequence of probability distributions with discretization levels . ∞>h0>h1⋯>hL. In many practical problems of interest, one cannot achieve an i.i.d. sampling of the associated sequence and a sequential Monte Carlo (SMC) version of the MLMC method is introduced to deal with this problem. It is shown that under appropriate assumptions, the attractive property of a reduction of the amount of computational effort to estimate expectations, for a given level of error, can be maintained within the SMC context. That is, relative to exact sampling and Monte Carlo for the distribution at the finest level . hL. The approach is numerically illustrated on a Bayesian inverse problem. © 2016 Elsevier B.V.

  12. Comparing two Poisson populations sequentially: an application

    International Nuclear Information System (INIS)

    Halteman, E.J.

    1986-01-01

    Rocky Flats Plant in Golden, Colorado monitors each of its employees for radiation exposure. Excess exposure is detected by comparing the means of two Poisson populations. A sequential probability ratio test (SPRT) is proposed as a replacement for the fixed sample normal approximation test. A uniformly most efficient SPRT exists, however logistics suggest using a truncated SPRT. The truncated SPRT is evaluated in detail and shown to possess large potential savings in average time spent by employees in the monitoring process

  13. Sequential Monte Carlo with Highly Informative Observations

    OpenAIRE

    Del Moral, Pierre; Murray, Lawrence M.

    2014-01-01

    We propose sequential Monte Carlo (SMC) methods for sampling the posterior distribution of state-space models under highly informative observation regimes, a situation in which standard SMC methods can perform poorly. A special case is simulating bridges between given initial and final values. The basic idea is to introduce a schedule of intermediate weighting and resampling times between observation times, which guide particles towards the final state. This can always be done for continuous-...

  14. Adaptive sequential controller

    Energy Technology Data Exchange (ETDEWEB)

    El-Sharkawi, Mohamed A. (Renton, WA); Xing, Jian (Seattle, WA); Butler, Nicholas G. (Newberg, OR); Rodriguez, Alonso (Pasadena, CA)

    1994-01-01

    An adaptive sequential controller (50/50') for controlling a circuit breaker (52) or other switching device to substantially eliminate transients on a distribution line caused by closing and opening the circuit breaker. The device adaptively compensates for changes in the response time of the circuit breaker due to aging and environmental effects. A potential transformer (70) provides a reference signal corresponding to the zero crossing of the voltage waveform, and a phase shift comparator circuit (96) compares the reference signal to the time at which any transient was produced when the circuit breaker closed, producing a signal indicative of the adaptive adjustment that should be made. Similarly, in controlling the opening of the circuit breaker, a current transformer (88) provides a reference signal that is compared against the time at which any transient is detected when the circuit breaker last opened. An adaptive adjustment circuit (102) produces a compensation time that is appropriately modified to account for changes in the circuit breaker response, including the effect of ambient conditions and aging. When next opened or closed, the circuit breaker is activated at an appropriately compensated time, so that it closes when the voltage crosses zero and opens when the current crosses zero, minimizing any transients on the distribution line. Phase angle can be used to control the opening of the circuit breaker relative to the reference signal provided by the potential transformer.

  15. Adaptive sequential controller

    Science.gov (United States)

    El-Sharkawi, Mohamed A.; Xing, Jian; Butler, Nicholas G.; Rodriguez, Alonso

    1994-01-01

    An adaptive sequential controller (50/50') for controlling a circuit breaker (52) or other switching device to substantially eliminate transients on a distribution line caused by closing and opening the circuit breaker. The device adaptively compensates for changes in the response time of the circuit breaker due to aging and environmental effects. A potential transformer (70) provides a reference signal corresponding to the zero crossing of the voltage waveform, and a phase shift comparator circuit (96) compares the reference signal to the time at which any transient was produced when the circuit breaker closed, producing a signal indicative of the adaptive adjustment that should be made. Similarly, in controlling the opening of the circuit breaker, a current transformer (88) provides a reference signal that is compared against the time at which any transient is detected when the circuit breaker last opened. An adaptive adjustment circuit (102) produces a compensation time that is appropriately modified to account for changes in the circuit breaker response, including the effect of ambient conditions and aging. When next opened or closed, the circuit breaker is activated at an appropriately compensated time, so that it closes when the voltage crosses zero and opens when the current crosses zero, minimizing any transients on the distribution line. Phase angle can be used to control the opening of the circuit breaker relative to the reference signal provided by the potential transformer.

  16. Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases.

    Science.gov (United States)

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2015-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml.

  17. Quantum Inequalities and Sequential Measurements

    International Nuclear Information System (INIS)

    Candelpergher, B.; Grandouz, T.; Rubinx, J.L.

    2011-01-01

    In this article, the peculiar context of sequential measurements is chosen in order to analyze the quantum specificity in the two most famous examples of Heisenberg and Bell inequalities: Results are found at some interesting variance with customary textbook materials, where the context of initial state re-initialization is described. A key-point of the analysis is the possibility of defining Joint Probability Distributions for sequential random variables associated to quantum operators. Within the sequential context, it is shown that Joint Probability Distributions can be defined in situations where not all of the quantum operators (corresponding to random variables) do commute two by two. (authors)

  18. Validation of an indirect ELISA to detect antibodies against BoHV-1 in bovine and guinea-pig serum samples using ISO/IEC 17025 standards.

    Science.gov (United States)

    Parreño, Viviana; Romera, S Alejandra; Makek, Lucia; Rodriguez, Daniela; Malacari, Darío; Maidana, Silvina; Compaired, Diego; Combessies, Gustavo; Vena, María Marta; Garaicoechea, Lorena; Wigdorovitz, Andrés; Marangunich, Laura; Fernandez, Fernando

    2010-10-01

    Two ELISAs to quantify antibodies to BoHV-1 in the sera of cattle and immunized guinea pigs were developed and validated using ISO/IEC 17025 standards. The cut-off value of the assay was established at 20% positivity of a high positive control for screening of cattle. Using this threshold, the assay properly classified the OIE bovine reference sera EU1, EU2 and EU3. For vaccine potency testing, a cut-off of 40% was selected for both species. The reliability of the assays, given by their diagnostic sensitivity and specificity, using the threshold of 40% was 89.7% and 100%, respectively, for bovines and 94.9% and 100% for guinea pigs, respectively. There was almost perfect agreement between the ELISA and virus neutralization results. In addition, after vaccination, there was a good correlation between the neutralizing and ELISA antibody titers of the serum from the same bovine or guinea pig, sampled at 60 and 30 days post-vaccination, respectively (R(bovine)=0.88, R(guinea pig)=0.92; p<0.0001). A similar correlation was observed when analyzing the mean antibody titers of groups of vaccinated animals (R(bovine)=0.95 and R(guinea pig)=0.97; p<0.0001), indicating the relevance of the ELISAs for batch to batch vaccine potency testing in the target species and in the laboratory animal model. The intermediate precision of the assays expressed as the relative coefficient of variation (CV) of the positive control assayed over a 3-year period in the same laboratory was 22.2% for bovines and 23.1% for guinea pigs. The reproducibility of both techniques obtained in inter-laboratory assays was CV=12.4% for bovines and CV approximately 0 for guinea pigs, which met the requirements of the OIE (CV<30%). The validated ELISAs represent important methods for vaccine potency testing and for controlling BoHV-1 infections. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  19. Framework for sequential approximate optimization

    NARCIS (Netherlands)

    Jacobs, J.H.; Etman, L.F.P.; Keulen, van F.; Rooda, J.E.

    2004-01-01

    An object-oriented framework for Sequential Approximate Optimization (SAO) isproposed. The framework aims to provide an open environment for thespecification and implementation of SAO strategies. The framework is based onthe Python programming language and contains a toolbox of Python

  20. Sequentially pulsed traveling wave accelerator

    Science.gov (United States)

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA; Poole, Brian R [Tracy, CA

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  1. Quantitative analysis of O-isopropyl methylphosphonic acid in serum samples of Japanese citizens allegedly exposed to sarin: Estimation of internal dosage

    NARCIS (Netherlands)

    Noort, D.; Hulst, A.G.; Platenburg, D.H.J.M.; Polhuijs, M.; Benschop, H.P.

    1998-01-01

    A convenient and rapid micro-anion exchange liquid chromatography (LC) tandem electrospray mass spectrometry (MS) procedure was developed for quantitative analysis in serum of O-isopropyl methylphosphonic acid (IMPA), the hydrolysis product of the nerve agent sarin. The mass spectrometric procedure

  2. [The National Serum Bank].

    Science.gov (United States)

    Magos-López, C; Sánchez-Villarreal, F; Gutiérrez, G; Tapia-Conyer, R

    1992-01-01

    A National Serum Bank was established to store sera obtained during the National Seroepidemiological Survey performed in Mexico in 1987. More than 70,000 serum samples were obtained from subjects of either sex 1-99 years of age in each of the 32 states of the country. The current collection of sera includes 28,704 male samples and 40,629 female samples. This paper describes the procedures for handling serum samples, including reception registry, storage and distribution to several laboratories for detection of measles, rubella, poliomyelitis, AIDS, diphtheria, pertussis, tetanus, brucella, salmonella, amoeba, toxoplasma, American trypanosomiasis and cysticercus. Determinations of total cholesterol were also made in order to describe its distribution and to identify the prevalence of hypercholesterolemia.

  3. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  4. Method validation for preparing serum and plasma samples from human blood for downstream proteomic, metabolomic, and circulating nucleic acid-based applications.

    Science.gov (United States)

    Ammerlaan, Wim; Trezzi, Jean-Pierre; Lescuyer, Pierre; Mathay, Conny; Hiller, Karsten; Betsou, Fay

    2014-08-01

    Formal method validation for biospecimen processing in the context of accreditation in laboratories and biobanks is lacking. Serum and plasma processing protocols were validated for fitness-for-purpose in terms of key downstream endpoints, and this article demonstrates methodology for biospecimen processing method validation. Serum and plasma preparation from human blood was optimized for centrifugation conditions with respect to microparticle counts. Optimal protocols were validated for methodology and reproducibility in terms of acceptance criteria based on microparticle counts, DNA and hemoglobin concentration, and metabolomic and proteomic profiles. These parameters were also used to evaluate robustness for centrifugation temperature (4°C versus room temperature [RT]), deceleration (low, medium, high) and blood stability (after a 2-hour delay). Optimal protocols were 10-min centrifugation for serum and 20-min for plasma at 2000 g, medium brake, RT. Methodology and reproducibility acceptance criteria were met for both protocols except for reproducibility of plasma metabolomics. Overall, neither protocol was robust for centrifugation at 4°C versus RT. RT gave higher microparticles and free DNA yields in serum, and fewer microparticles with less hemolysis in plasma. Overall, both protocols were robust for fast, medium, and low deceleration, with a medium brake considered optimal. Pre-centrifugation stability after a 2-hour delay was seen at both temperatures for hemoglobin concentration and proteomics, but not for microparticle counts. We validated serum and plasma collection methods suitable for downstream protein, metabolite, or free nucleic acid-based applications. Temperature and pre-centrifugation delay can influence analytic results, and laboratories and biobanks should systematically record these conditions in the scope of accreditation.

  5. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239.

    Science.gov (United States)

    Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin

    2013-06-01

    Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.

  6. Comparison of immunofluorescence and enzyme-linked immunosorbent assay and immunoglobulin G avidity techniques for screening of anti: Toxoplasma antibodies among single serum sample pregnant women in Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Mehrangiz Rajaii

    2015-01-01

    Full Text Available Background: Congenital toxoplasmosis is that pregnant women acquire the infection during gestation; diagnosis of the acute infection during pregnancy is a complex subject of maternal toxoplasmosis. Thus, the presence of immunoglobulin G (IgG and/or IgM Toxoplasma antibodies in a single serum sample drawn during gestation cannot be used to define whether the infection was recently acquired or chronic. Materials and Methods: At this cross-sectional descriptive study, sera of 391 pregnant women examined and compared. They were in an age range of 21-35 years, referred by gynecologists and infectious disease specialists, during March 2012-April 2013. They have referred, 215 (54.98%, 102 (26%, 74 (18.92% in the first, second and third trimesters of gestation, respectively. For each of them, a questionnaire was completed and serum samples were prepared in an equal condition, examined according to the procedures of indirect immunofluorescence (IIF, enzyme-linked immunosorbent assay (ELISA and IgG Avidity techniques. Results: We have found 111 (28.38% seronegative and 280 (71.61% seropositive cases by IIF and 124 (31.70% seronegative, 267 (68.28% seropositive cases by ELISA. The IgG avidity test confirmed 45 (69.23% and 7 (10.76% doubtful cases of IgM test in IIF and ELISA techniques. Conclusions: This study highlights how to manage pregnant women with toxoplasmosis, especially in a single serum sample condition.

  7. Neutralizing antibodies against two HIV-1 strains in consecutively collected serum samples: cross neutralization and association to HIV-1 related disease

    DEFF Research Database (Denmark)

    Arendrup, M; Nielsen, C M; Hansen, J E

    1992-01-01

    97 sera collected during a 10-year period from 10 HIV-1 infected individuals were tested for neutralizing capacity against a virus isolate FICPH-22 obtained from a Danish AIDS patient, and the laboratory strain HTLV-IIIB. Three patterns of serum neutralizing activity were demonstrated: (a) patients...... developing high neutralizing activity against both HIV strains; (b) patients developing high neutralizing activity against the Danish virus isolate; and (c) patients developing only low titers of neutralizing antibodies (NA) against both HIV strains. The HTLV-IIIB strain was less sensitive to serum...... neutralization than the FICPH-22 isolate and the appearance of NA against HTLV-IIIB was typically lacking several years behind that against FICPH-22 indicating a broadening of the NA response over time. No difference in clinical outcome was observed comparing patients reaching high titers of NA and patients...

  8. Heat accumulation during sequential cortical bone drilling.

    Science.gov (United States)

    Palmisano, Andrew C; Tai, Bruce L; Belmont, Barry; Irwin, Todd A; Shih, Albert; Holmes, James R

    2016-03-01

    Significant research exists regarding heat production during single-hole bone drilling. No published data exist regarding repetitive sequential drilling. This study elucidates the phenomenon of heat accumulation for sequential drilling with both Kirschner wires (K wires) and standard two-flute twist drills. It was hypothesized that cumulative heat would result in a higher temperature with each subsequent drill pass. Nine holes in a 3 × 3 array were drilled sequentially on moistened cadaveric tibia bone kept at body temperature (about 37 °C). Four thermocouples were placed at the center of four adjacent holes and 2 mm below the surface. A battery-driven hand drill guided by a servo-controlled motion system was used. Six samples were drilled with each tool (2.0 mm K wire and 2.0 and 2.5 mm standard drills). K wire drilling increased temperature from 5 °C at the first hole to 20 °C at holes 6 through 9. A similar trend was found in standard drills with less significant increments. The maximum temperatures of both tools increased from drill sizes was found to be insignificant (P > 0.05). In conclusion, heat accumulated during sequential drilling, with size difference being insignificant. K wire produced more heat than its twist-drill counterparts. This study has demonstrated the heat accumulation phenomenon and its significant effect on temperature. Maximizing the drilling field and reducing the number of drill passes may decrease bone injury. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  9. Are serum adiponectin concentrations in a population sample of 64-year-old Caucasian women with varying glucose tolerance associated with ultrasound-assessed atherosclerosis?

    Science.gov (United States)

    Behre, C J; Brohall, G; Hulthe, J; Wikstrand, J; Fagerberg, B

    2006-09-01

    To examine whether serum adiponectin concentrations were associated with subclinical atherosclerosis assessed as intima media thickness (IMT) in the carotid arteries in Caucasian women with varying degrees of glucose tolerance. From a population-based cohort of 64-year-old Swedish women, 533 subjects with type 2 diabetes (DM2, n=177), impaired glucose tolerance (IGT; n=178) or normal glucose tolerance (NGT, n=178) were recruited. Anthropometrics, usual cardiovascular risk factors were examined and ultrasound examination of the carotid arteries was performed. Women with low adiponectin concentrations were characterized by thick IMT, higher prevalence of DM2, history of previous myocardial infarction, angina pectoris, anti-hypertensive treatment and high body mass index (BMI), waist circumference, plasma insulin, serum triglycerides, fasting glucose, HbA1c, and low serum HDL cholesterol levels. Carotid IMT correlated with HbA1c (r=0.24, PDM2 (r=0.16, P<0.001), systolic blood pressure (r=0.16, P<0.001), blood glucose (r=0.16, P<0.001), triglycerides (r=0.15, P<0.001), and reversely to adiponectin (r=-0.11, P=0.01), HDL cholesterol (r=-0.13, P=0.004), and alcohol intake (r=-0.087, P<0.05). A more detailed analysis of underlying associations was difficult due to a high co-linearity between these variable. Low serum adiponectin concentrations were associated with increased carotid artery IMT, and several risk factors for cardiovascular diseases, mainly those constituting the metabolic syndrome.

  10. Remarks on sequential designs in risk assessment

    International Nuclear Information System (INIS)

    Seidenfeld, T.

    1982-01-01

    The special merits of sequential designs are reviewed in light of particular challenges that attend risk assessment for human population. The kinds of ''statistical inference'' are distinguished and the problem of design which is pursued is the clash between Neyman-Pearson and Bayesian programs of sequential design. The value of sequential designs is discussed and the Neyman-Pearson vs. Bayesian sequential designs are probed in particular. Finally, warnings with sequential designs are considered, especially in relation to utilitarianism

  11. Serum sickness

    Science.gov (United States)

    ... the problem should be stopped. Avoid using that medicine or antiserum in the future. ... Call your provider if you received medicine or antiserum in the last 4 weeks and have symptoms of serum sickness.

  12. Sequential extraction of uranium metal contamination

    International Nuclear Information System (INIS)

    Murry, M.M.; Spitz, H.B.; Connick, W.B.

    2016-01-01

    Samples of uranium contaminated dirt collected from the dirt floor of an abandoned metal rolling mill were analyzed for uranium using a sequential extraction protocol involving a series of five increasingly aggressive solvents. The quantity of uranium extracted from the contaminated dirt by each reagent can aid in predicting the fate and transport of the uranium contamination in the environment. Uranium was separated from each fraction using anion exchange, electrodeposition and analyzed by alpha spectroscopy analysis. Results demonstrate that approximately 77 % of the uranium was extracted using NH 4 Ac in 25 % acetic acid. (author)

  13. Sequential versus simultaneous market delineation

    DEFF Research Database (Denmark)

    Haldrup, Niels; Møllgaard, Peter; Kastberg Nielsen, Claus

    2005-01-01

    and geographical markets. Using a unique data setfor prices of Norwegian and Scottish salmon, we propose a methodologyfor simultaneous market delineation and we demonstrate that comparedto a sequential approach conclusions will be reversed.JEL: C3, K21, L41, Q22Keywords: Relevant market, econometric delineation......Delineation of the relevant market forms a pivotal part of most antitrustcases. The standard approach is sequential. First the product marketis delineated, then the geographical market is defined. Demand andsupply substitution in both the product dimension and the geographicaldimension...

  14. Sequential logic analysis and synthesis

    CERN Document Server

    Cavanagh, Joseph

    2007-01-01

    Until now, there was no single resource for actual digital system design. Using both basic and advanced concepts, Sequential Logic: Analysis and Synthesis offers a thorough exposition of the analysis and synthesis of both synchronous and asynchronous sequential machines. With 25 years of experience in designing computing equipment, the author stresses the practical design of state machines. He clearly delineates each step of the structured and rigorous design principles that can be applied to practical applications. The book begins by reviewing the analysis of combinatorial logic and Boolean a

  15. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...... assumed to be normally distributed, and sequential one-sided hypothesis tests on the population standard deviation of the differences against a hypothesised value of 1.5 were performed, employing an alpha spending function. The fixed-sample analysis (N = 45) was compared with the group-sequential analysis...... strategies comprising one (at N = 23), two (at N = 15, 30), or three interim analyses (at N = 11, 23, 34), respectively, which were defined post hoc. RESULTS: When performing interim analyses with one third and two thirds of patients, sufficient agreement could be concluded after the first interim analysis...

  16. Multilevel sequential Monte-Carlo samplers

    KAUST Repository

    Jasra, Ajay

    2016-01-01

    Multilevel Monte-Carlo methods provide a powerful computational technique for reducing the computational cost of estimating expectations for a given computational effort. They are particularly relevant for computational problems when approximate distributions are determined via a resolution parameter h, with h=0 giving the theoretical exact distribution (e.g. SDEs or inverse problems with PDEs). The method provides a benefit by coupling samples from successive resolutions, and estimating differences of successive expectations. We develop a methodology that brings Sequential Monte-Carlo (SMC) algorithms within the framework of the Multilevel idea, as SMC provides a natural set-up for coupling samples over different resolutions. We prove that the new algorithm indeed preserves the benefits of the multilevel principle, even if samples at all resolutions are now correlated.

  17. Multilevel sequential Monte-Carlo samplers

    KAUST Repository

    Jasra, Ajay

    2016-01-05

    Multilevel Monte-Carlo methods provide a powerful computational technique for reducing the computational cost of estimating expectations for a given computational effort. They are particularly relevant for computational problems when approximate distributions are determined via a resolution parameter h, with h=0 giving the theoretical exact distribution (e.g. SDEs or inverse problems with PDEs). The method provides a benefit by coupling samples from successive resolutions, and estimating differences of successive expectations. We develop a methodology that brings Sequential Monte-Carlo (SMC) algorithms within the framework of the Multilevel idea, as SMC provides a natural set-up for coupling samples over different resolutions. We prove that the new algorithm indeed preserves the benefits of the multilevel principle, even if samples at all resolutions are now correlated.

  18. Evaluation Using Sequential Trials Methods.

    Science.gov (United States)

    Cohen, Mark E.; Ralls, Stephen A.

    1986-01-01

    Although dental school faculty as well as practitioners are interested in evaluating products and procedures used in clinical practice, research design and statistical analysis can sometimes pose problems. Sequential trials methods provide an analytical structure that is both easy to use and statistically valid. (Author/MLW)

  19. Attack Trees with Sequential Conjunction

    NARCIS (Netherlands)

    Jhawar, Ravi; Kordy, Barbara; Mauw, Sjouke; Radomirović, Sasa; Trujillo-Rasua, Rolando

    2015-01-01

    We provide the first formal foundation of SAND attack trees which are a popular extension of the well-known attack trees. The SAND at- tack tree formalism increases the expressivity of attack trees by intro- ducing the sequential conjunctive operator SAND. This operator enables the modeling of

  20. Biochemical studies of Piper betle L leaf extract on obese treated animal using 1H-NMR-based metabolomic approach of blood serum samples.

    Science.gov (United States)

    Abdul Ghani, Zuleen Delina Fasya; Husin, Juani Mazmin; Rashid, Ahmad Hazri Ab; Shaari, Khozirah; Chik, Zamri

    2016-12-24

    Piper betle L. (PB) belongs to the Piperaceae family. The presence of a fairly large quantity of diastase in the betel leaf is deemed to play an important role in starch digestion and calls for the study of weight loss activities and metabolite profile from PB leaf extracts using metabolomics approach to be performed. PB dried leaves were extracted with 70% ethanol and the extracts were subjected to five groups of rats fed with high fat (HF) and standard diet (SD). They were then fed with the extracts in two doses and compared with a negative control group given water only according to the study protocol. The body weights and food intakes were monitored every week. At the end of the study, blood serum of the experimental animal was analysed to determine the biochemical and metabolite changes. PB treated group demonstrated inhibition of body weight gain without showing an effect on the food intake. In serum bioassay, the PB treated group (HF/PB (100mg/kg and 500mg/kg) showed an increased in glucose and cholesterol levels compared to the Standard Diet (SD/WTR) group, a decrease in LDL level and increase in HDL level when compared with High Fat Diet (HF/WTR) group. For metabolite analysis, two separation models were made to determine the metabolite changes via group activities. The best separation of PCA serum in Model 1 and 2 was achieved in principle component 1 and principle component 2. SUS-Plot model showed that HF group was characterized by high-level of glucose, glycine and alanine. Increase in the β-hydroxybutyrate level similar with SD group animals was evident in the HF/PB(500mg/kg) group. This finding suggested that the administration of 500mg/kg PB extracts leads to increase in oxidation process in the body thus maintaining the body weight and without giving an effect on the appetite even though HF was continuously consumed by the animals until the end of the studies and also a reduction in food intake, thus maintaining their body weight although they

  1. Sequential ensemble-based optimal design for parameter estimation: SEQUENTIAL ENSEMBLE-BASED OPTIMAL DESIGN

    Energy Technology Data Exchange (ETDEWEB)

    Man, Jun [Zhejiang Provincial Key Laboratory of Agricultural Resources and Environment, Institute of Soil and Water Resources and Environmental Science, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou China; Zhang, Jiangjiang [Zhejiang Provincial Key Laboratory of Agricultural Resources and Environment, Institute of Soil and Water Resources and Environmental Science, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou China; Li, Weixuan [Pacific Northwest National Laboratory, Richland Washington USA; Zeng, Lingzao [Zhejiang Provincial Key Laboratory of Agricultural Resources and Environment, Institute of Soil and Water Resources and Environmental Science, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou China; Wu, Laosheng [Department of Environmental Sciences, University of California, Riverside California USA

    2016-10-01

    The ensemble Kalman filter (EnKF) has been widely used in parameter estimation for hydrological models. The focus of most previous studies was to develop more efficient analysis (estimation) algorithms. On the other hand, it is intuitively understandable that a well-designed sampling (data-collection) strategy should provide more informative measurements and subsequently improve the parameter estimation. In this work, a Sequential Ensemble-based Optimal Design (SEOD) method, coupled with EnKF, information theory and sequential optimal design, is proposed to improve the performance of parameter estimation. Based on the first-order and second-order statistics, different information metrics including the Shannon entropy difference (SD), degrees of freedom for signal (DFS) and relative entropy (RE) are used to design the optimal sampling strategy, respectively. The effectiveness of the proposed method is illustrated by synthetic one-dimensional and two-dimensional unsaturated flow case studies. It is shown that the designed sampling strategies can provide more accurate parameter estimation and state prediction compared with conventional sampling strategies. Optimal sampling designs based on various information metrics perform similarly in our cases. The effect of ensemble size on the optimal design is also investigated. Overall, larger ensemble size improves the parameter estimation and convergence of optimal sampling strategy. Although the proposed method is applied to unsaturated flow problems in this study, it can be equally applied in any other hydrological problems.

  2. Metabolomic and Lipidomic Analysis of Serum Samples following Curcuma longa Extract Supplementation in High-Fructose and Saturated Fat Fed Rats.

    Science.gov (United States)

    Tranchida, Fabrice; Shintu, Laetitia; Rakotoniaina, Zo; Tchiakpe, Léopold; Deyris, Valérie; Hiol, Abel; Caldarelli, Stefano

    2015-01-01

    We explored, using nuclear magnetic resonance (NMR) metabolomics and fatty acids profiling, the effects of a common nutritional complement, Curcuma longa, at a nutritionally relevant dose with human use, administered in conjunction with an unbalanced diet. Indeed, traditional food supplements have been long used to counter metabolic impairments induced by unbalanced diets. Here, rats were fed either a standard diet, a high level of fructose and saturated fatty acid (HFS) diet, a diet common to western countries and that certainly contributes to the epidemic of insulin resistance (IR) syndrome, or a HFS diet with a Curcuma longa extract (1% of curcuminoids in the extract) for ten weeks. Orthogonal projections to latent structures discriminant analysis (OPLS-DA) on the serum NMR profiles and fatty acid composition (determined by GC/MS) showed a clear discrimination between HFS groups and controls. This discrimination involved metabolites such as glucose, amino acids, pyruvate, creatine, phosphocholine/glycerophosphocholine, ketone bodies and glycoproteins as well as an increase of monounsaturated fatty acids (MUFAs) and a decrease of n-6 and n-3 polyunsaturated fatty acids (PUFAs). Although the administration of Curcuma longa did not prevent the observed increase of glucose, triglycerides, cholesterol and insulin levels, discriminating metabolites were observed between groups fed HFS alone or with addition of a Curcuma longa extract, namely some MUFA and n-3 PUFA, glycoproteins, glutamine, and methanol, suggesting that curcuminoids may act respectively on the fatty acid metabolism, the hexosamine biosynthesis pathway and alcohol oxidation. Curcuma longa extract supplementation appears to be beneficial in these metabolic pathways in rats. This metabolomic approach highlights important serum metabolites that could help in understanding further the metabolic mechanisms leading to IR.

  3. Assessment of CCL2 and CXCL8 chemokines in serum, bronchoalveolar lavage fluid and lung tissue samples from dogs affected with canine idiopathic pulmonary fibrosis.

    Science.gov (United States)

    Roels, Elodie; Krafft, Emilie; Farnir, Frederic; Holopainen, Saila; Laurila, Henna P; Rajamäki, Minna M; Day, Michael J; Antoine, Nadine; Pirottin, Dimitri; Clercx, Cecile

    2015-10-01

    Canine idiopathic pulmonary fibrosis (CIPF) is a progressive disease of the lung parenchyma that is more prevalent in dogs of the West Highland white terrier (WHWT) breed. Since the chemokines (C-C motif) ligand 2 (CCL2) and (C-X-C motif) ligand 8 (CXCL8) have been implicated in pulmonary fibrosis in humans, the aim of the present study was to investigate whether these same chemokines are involved in the pathogenesis of CIPF. CCL2 and CXCL8 concentrations were measured by ELISA in serum and bronchoalveolar lavage fluid (BALF) from healthy dogs and WHWTs affected with CIPF. Expression of the genes encoding CCL2 and CXCL8 and their respective receptors, namely (C-C motif) receptor 2 (CCR2) and (C-X-C motif) receptor 2 (CXCR2), was compared in unaffected lung tissue and biopsies from dogs affected with CIPF by quantitative PCR and localisation of CCL2 and CXCL8 proteins were determined by immunohistochemistry. Significantly greater CCL2 and CXCL8 concentrations were found in the BALF from WHWTs affected with CIPF, compared with healthy dogs. Significantly greater serum concentrations of CCL2, but not CXCL8, were found in CIPF-affected dogs compared with healthy WHWTs. No differences in relative gene expression for CCL2, CXCL8, CCR2 or CXCR2 were observed when comparing lung biopsies from control dogs and those affected with CIPF. In affected lung tissues, immunolabelling for CCL2 and CXCL8 was observed in bronchial airway epithelial cells in dogs affected with CIPF. The study findings suggest that both CCL2 and CXCL8 are involved in the pathogenesis of CIPF. Further studies are required to determine whether these chemokines might have a clinical use as biomarkers of fibrosis or as targets for therapeutic intervention. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Low ficolin-3 levels in early follow-up serum samples are associated with the severity and unfavorable outcome of acute ischemic stroke

    DEFF Research Database (Denmark)

    Füst, George; Munthe-Fog, Lea; Illes, Zsolt

    2011-01-01

    demonstrated the significance of MBL in ischemic stroke, the role of ficolins has not been examined. METHODS: Sera were obtained within 12 hours after the onset of ischemic stroke (admission samples) and 3-4 days later (follow-up samples) from 65 patients. The control group comprised 100 healthy individuals......-up samples an inverse correlation was observed between ficolin-3 levels and concentration of S100β, an indicator of the size of cerebral infarct. Patients with low ficolin-3 levels and high CRP levels in the follow up samples had a significantly worse outcome (adjusted ORs 5.6 and 3.9, respectively...

  5. Smart management of sample dilution using an artificial neural network to achieve streamlined processes and saving resources: the automated nephelometric testing of serum free light chain as case study.

    Science.gov (United States)

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.

  6. Prevalence of Peste Des Petits Ruminants Virus (PPRV in Mardan, Hangu and Kohat District of Pakistan; Comparative Analysis of PPRV Suspected serum samples using Competitive ELISA (cELISA and Agar Gel Immunodiffusion (AGID

    Directory of Open Access Journals (Sweden)

    Misbah Aslam

    2009-06-01

    Full Text Available Peste des petits Ruminants (PPR is an acute, febrile, highly contagious and economically important viral disease of small ruminants. However PPR is more prevalent in sheep and goat. Competitive ELISA, Virus neutrilization test, and RT-PCR are the available techniques for diagnosis of PPR which give rapid detection where as Agar gel immunodiffusion and Counter immunoelectrophoresis were previously used for PPR detection. In this study two serological techniques were compared for PPR diagnosis. The main aim of this study was to evaluate the comparative sensitivity of both techniques for PPR detection. For this purpose one hundred and sixty PPR suspected serum samples collected from goats and sheep flocks (unvaccinated from three Districts of NWFP including Mardan, Hangu and Kohat were analyzed in National Veterinary Laboratories, Islamabad. Out of these 160 samples, fifty (50 were found positive for PPR antibodies with cELISA (Prevalence = 31.25%. The cELISA positive serum samples however gave negative results when tested with AGID although the control well was always positive. Thus it was concluded that cELISA technique is more sensitive and specific than AGID for PPR antibody detection. [Vet. World 2009; 2(3.000: 89-92

  7. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.; Shamma, Jeff S.

    2014-01-01

    incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well

  8. Automated sequential injection-microcolumn approach with on-line flame atomic absorption spectrometric detection for implementing metal fractionation schemes of homogeneous and non-homogeneous solid samples of environmental interest

    DEFF Research Database (Denmark)

    Chomchoei, Roongrat; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    spectrometric detection and used for the determination of Cu as a model analyte, the potentials of this novel hyphenated approach are demonstrated by the ability of handling up to 300 mg sample of a nonhomogeneous sewage amended soil (viz., CRM 483). The three steps of the endorsed Standards, Measurements...

  9. Robustness of the Sequential Lineup Advantage

    Science.gov (United States)

    Gronlund, Scott D.; Carlson, Curt A.; Dailey, Sarah B.; Goodsell, Charles A.

    2009-01-01

    A growing movement in the United States and around the world involves promoting the advantages of conducting an eyewitness lineup in a sequential manner. We conducted a large study (N = 2,529) that included 24 comparisons of sequential versus simultaneous lineups. A liberal statistical criterion revealed only 2 significant sequential lineup…

  10. Sequential Probability Ration Tests : Conservative and Robust

    NARCIS (Netherlands)

    Kleijnen, J.P.C.; Shi, Wen

    2017-01-01

    In practice, most computers generate simulation outputs sequentially, so it is attractive to analyze these outputs through sequential statistical methods such as sequential probability ratio tests (SPRTs). We investigate several SPRTs for choosing between two hypothesized values for the mean output

  11. Comparison of IGF-1 (insulin like growth factor-1) levels in bovine serum sampled three times during the day using validated equine IGF-1 elisa

    OpenAIRE

    Mrkun J.; Kosec M.; Zrimšek Petra

    2009-01-01

    Cows in negative energy balance exhibit reduced fertility, mediated by metabolic signals that influence the reproductive system. Measurement of IGF-1 contributes to the diagnosis of negative energy balance. The aim of this study was to investigate possible variations in IGF-1 levels in samples taken at different times of the day. Equine IGF-1 ELISA was used for measuring IGF-1 in bovine samples. Statistical analysis was applied to the results. Using scatter diagrams fitted with Deming regress...

  12. Sequential Analysis of Metals in Municipal Dumpsite Composts of ...

    African Journals Online (AJOL)

    ... Ni) in Municipal dumpsite compost were determined by the sequential extraction method. Chemical parameters such as pH, conductivity, and organic carbon contents of the samples were also determined. Analysis of the extracts was carried out by atomic absorption spectrophotometer machine (Buck Scientific VPG 210).

  13. An automatic system for acidity determination based on sequential injection titration and the monosegmented flow approach.

    Science.gov (United States)

    Kozak, Joanna; Wójtowicz, Marzena; Gawenda, Nadzieja; Kościelniak, Paweł

    2011-06-15

    An automatic sequential injection system, combining monosegmented flow analysis, sequential injection analysis and sequential injection titration is proposed for acidity determination. The system enables controllable sample dilution and generation of standards of required concentration in a monosegmented sequential injection manner, sequential injection titration of the prepared solutions, data collecting, and handling. It has been tested on spectrophotometric determination of acetic, citric and phosphoric acids with sodium hydroxide used as a titrant and phenolphthalein or thymolphthalein (in the case of phosphoric acid determination) as indicators. Accuracy better than |4.4|% (RE) and repeatability better than 2.9% (RSD) have been obtained. It has been applied to the determination of total acidity in vinegars and various soft drinks. The system provides low sample (less than 0.3 mL) consumption. On average, analysis of a sample takes several minutes. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. The pursuit of balance in sequential randomized trials

    Directory of Open Access Journals (Sweden)

    Raymond P. Guiteras

    2016-06-01

    Full Text Available In many randomized trials, subjects enter the sample sequentially. Because the covariates for all units are not known in advance, standard methods of stratification do not apply. We describe and assess the method of DA-optimal sequential allocation (Atkinson, 1982 for balancing stratification covariates across treatment arms. We provide simulation evidence that the method can provide substantial improvements in precision over commonly employed alternatives. We also describe our experience implementing the method in a field trial of a clean water and handwashing intervention in Dhaka, Bangladesh, the first time the method has been used. We provide advice and software for future researchers.

  15. Facile Synthesis of Mesocrystalline SnO2 Nanorods on Reduced Graphene Oxide Sheets: An Appealing Multifunctional Affinity Probe for Sequential Enrichment of Endogenous Peptides and Phosphopeptides.

    Science.gov (United States)

    Ma, Wen; Zhang, Feng; Li, Liping; Chen, Shuai; Qi, Limin; Liu, Huwei; Bai, Yu

    2016-12-28

    A novel multifunctional composite comprising mesocrystalline SnO 2 nanorods (NRs) vertically aligned on reduced graphene oxide (rGO) sheets was synthesized and developed for sequential capture of endogenous peptides and phosphopeptides. With the hydrophobicity of rGO and high affinity of SnO 2 nanorods, sequential enrichment of endogenous peptides and phosphopeptides could be easily achieved through a modulation of elution buffer. With this multifunctional nanomaterial, 36 peptides were observed from diluted bovine serum albumin (BSA) tryptic digest and 4 phosphopeptides could be selectively captured from β-casein digest. The detection limit of tryptic digest of β-casein was low to 4 × 10 -10 M, and the selectivity was up to 1:500 (molar ratio of β-casein and BSA digest). The effectiveness and robustness of rGO-SnO 2 NRs in a complex biological system was also confirmed by using human serum as a real sample. Our work is promising for small peptide enrichment and identification especially in complicated biological sample preparation, which also opens a new perspective in the design of multifunctional affinity probes for proteome or peptidome.

  16. Combination of atomic force microscopy and mass spectrometry for the detection of target protein in the serum samples of children with autism spectrum disorders

    Science.gov (United States)

    Kaysheva, A. L.; Pleshakova, T. O.; Kopylov, A. T.; Shumov, I. D.; Iourov, I. Y.; Vorsanova, S. G.; Yurov, Y. B.; Ziborov, V. S.; Archakov, A. I.; Ivanov, Y. D.

    2017-10-01

    Possibility of detection of target proteins associated with development of autistic disorders in children with use of combined atomic force microscopy and mass spectrometry (AFM/MS) method is demonstrated. The proposed method is based on the combination of affine enrichment of proteins from biological samples and visualization of these proteins by AFM and MS analysis with quantitative detection of target proteins.

  17. Impact of emotional support on serum cortisol in breast cancer patients

    Directory of Open Access Journals (Sweden)

    Sampoornam Webster

    2016-01-01

    Methods: The study was designed to compare the effectiveness of emotional support focused nurse directed intervention in terms of verbal, written and telephone basis on serum cortisol among breast cancer patients in Cancer Centre at Erode. Participants were randomly allocated by using Sequentially Numbered Opaque Sealed Envelope (SNOSE method. 2 ml of blood samples were collected from 30 breast cancer patients who were selected randomly by adopting random number table, 10 in each experimental arm during evening at 18 hour; radioimmunoassay method was used to measure the level of serum cortisol before and after intervention. The intervention was given twice in a week for the duration of 30-45 minutes, in which early 20-30 minutes spares to express thoughts and feelings of the participants and subsequent 10-15 minutes for rendering informational support and later follow up session for the period of 1 month. Results: Emotional support was effective in reducing serum cortisol level among breast cancer patients. There was no statistically significant difference between arms on serum cortisol levels. Conclusions: Marginal differences were noted between posttest mean scores of serum cortisol among verbal, written and telephone arms. Further emotional support can be rendered according to the preference of the breast cancer patients.

  18. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    International Nuclear Information System (INIS)

    Ameli, Akram; Alizadeh, Naader

    2011-01-01

    Highlights: ► Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. ► This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. ► Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 × 10 −8 to 5 × 10 −4 and 1.2 × 10 −6 to 5 × 10 −4 mol mL −1 and the detection limit was 4 × 10 −8 mol L −1 . The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  19. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ameli, Akram [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Alizadeh, Naader, E-mail: alizaden@modares.ac.ir [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of)

    2011-11-30

    Highlights: Black-Right-Pointing-Pointer Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. Black-Right-Pointing-Pointer This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. Black-Right-Pointing-Pointer Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 Multiplication-Sign 10{sup -8} to 5 Multiplication-Sign 10{sup -4} and 1.2 Multiplication-Sign 10{sup -6} to 5 Multiplication-Sign 10{sup -4} mol mL{sup -1} and the detection limit was 4 Multiplication-Sign 10{sup -8} mol L{sup -1}. The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  20. Evaluation of the Aptima HBV Quant assay vs. the COBAS TaqMan HBV test using the high pure system for the quantitation of HBV DNA in plasma and serum samples.

    Science.gov (United States)

    Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin

    2018-03-28

    Proper management of patients with chronic hepatitis B virus (HBV) infection requires monitoring of plasma or serum HBV DNA levels using a highly sensitive nucleic acid amplification test. Because commercially available assays differ in performance, we compared herein the performance of the Hologic Aptima HBV Quant assay (Aptima) to that of the Roche Cobas TaqMan HBV test for use with the high pure system (HPS/CTM). Assay performance was assessed using HBV reference panels as well as plasma and serum samples from chronically HBV-infected patients. Method correlation, analytical sensitivity, precision/reproducibility, linearity, bias and influence of genotype were evaluated. Data analysis was performed using linear regression, Deming correlation analysis and Bland-Altman analysis. Agreement between the assays for the two reference panels was good, with a difference in assay values vs. target 0.98). The two assays had similar bias and precision across the different genotypes tested at low viral loads (25-1000 IU/mL). Aptima has a performance comparable with that of HPS/CTM, making it suitable for use for HBV infection monitoring. Aptima runs on a fully automated platform (the Panther system) and therefore offers a significantly improved workflow compared with HPS/CTM.

  1. Versatile lipid profiling by liquid chromatography–high resolution mass spectrometry using all ion fragmentation and polarity switching. Preliminary application for serum samples phenotyping related to canine mammary cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gallart-Ayala, H., E-mail: laberca@oniris-nantes.fr [LUNAM, Ecole Nationale Vétérinaire, Agroalimentaire et de l’Alimentation Nantes Atlantique (Oniris), USC 1329 INRA Laboratoire d’Etude des résidus et Contaminants dans les Aliments (LABERCA), Site de la Chantrerie – CS50707, 44307 Nantes cedex 3 (France); Courant, F.; Severe, S.; Antignac, J.-P. [LUNAM, Ecole Nationale Vétérinaire, Agroalimentaire et de l’Alimentation Nantes Atlantique (Oniris), USC 1329 INRA Laboratoire d’Etude des résidus et Contaminants dans les Aliments (LABERCA), Site de la Chantrerie – CS50707, 44307 Nantes cedex 3 (France); Morio, F.; Abadie, J. [LUNAM, Ecole Nationale Vétérinaire, Agroalimentaire et de l’Alimentation Nantes Atlantique (Oniris), Cancers Animaux, Modèles pour la Recherche en Oncologie Comparée (AMaROC), Site de la Chantrerie–CS50707, 44307 Nantes cedex 3 (France); Le Bizec, B. [LUNAM, Ecole Nationale Vétérinaire, Agroalimentaire et de l’Alimentation Nantes Atlantique (Oniris), USC 1329 INRA Laboratoire d’Etude des résidus et Contaminants dans les Aliments (LABERCA), Site de la Chantrerie – CS50707, 44307 Nantes cedex 3 (France)

    2013-09-24

    Graphical abstract: -- Highlights: •Lipidomics, high resolution mass spectrometry, polarity switching, serum, canine mammary cancer. -- Abstract: Lipids represent an extended class of substances characterized by such high variety and complexity that makes their unified analyses by liquid chromatography coupled to either high resolution or tandem mass spectrometry (LC–HRMS or LC–MS/MS) a real challenge. In the present study, a new versatile methodology associating ultra high performance liquid chromatography coupled to high resolution tandem mass spectrometry (UHPLC–HRMS/MS) have been developed for a comprehensive analysis of lipids. The use of polarity switching and “all ion fragmentation” (AIF) have been two action levels particularly exploited to finally permit the detection and identification of a multi-class and multi-analyte extended range of lipids in a single run. For identification purposes, both higher energy collision dissociation (HCD) and in-source CID (collision induced dissociation) fragmentation were evaluated in order to obtain information about the precursor and product ions in the same spectra. This approach provides both class-specific and lipid-specific fragments, enhancing lipid identification. Finally, the developed method was applied for differential phenotyping of serum samples collected from pet dogs developing spontaneous malignant mammary tumors and health controls. A biological signature associated with the presence of cancer was then successfully revealed from this lipidome analysis, which required to be further investigated and confirmed at larger scale.

  2. Versatile lipid profiling by liquid chromatography–high resolution mass spectrometry using all ion fragmentation and polarity switching. Preliminary application for serum samples phenotyping related to canine mammary cancer

    International Nuclear Information System (INIS)

    Gallart-Ayala, H.; Courant, F.; Severe, S.; Antignac, J.-P.; Morio, F.; Abadie, J.; Le Bizec, B.

    2013-01-01

    Graphical abstract: -- Highlights: •Lipidomics, high resolution mass spectrometry, polarity switching, serum, canine mammary cancer. -- Abstract: Lipids represent an extended class of substances characterized by such high variety and complexity that makes their unified analyses by liquid chromatography coupled to either high resolution or tandem mass spectrometry (LC–HRMS or LC–MS/MS) a real challenge. In the present study, a new versatile methodology associating ultra high performance liquid chromatography coupled to high resolution tandem mass spectrometry (UHPLC–HRMS/MS) have been developed for a comprehensive analysis of lipids. The use of polarity switching and “all ion fragmentation” (AIF) have been two action levels particularly exploited to finally permit the detection and identification of a multi-class and multi-analyte extended range of lipids in a single run. For identification purposes, both higher energy collision dissociation (HCD) and in-source CID (collision induced dissociation) fragmentation were evaluated in order to obtain information about the precursor and product ions in the same spectra. This approach provides both class-specific and lipid-specific fragments, enhancing lipid identification. Finally, the developed method was applied for differential phenotyping of serum samples collected from pet dogs developing spontaneous malignant mammary tumors and health controls. A biological signature associated with the presence of cancer was then successfully revealed from this lipidome analysis, which required to be further investigated and confirmed at larger scale

  3. Proton NMR-based metabolite analyses of archived serial paired serum and urine samples from myeloma patients at different stages of disease activity identifies acetylcarnitine as a novel marker of active disease.

    Directory of Open Access Journals (Sweden)

    Alessia Lodi

    Full Text Available BACKGROUND: Biomarker identification is becoming increasingly important for the development of personalized or stratified therapies. Metabolomics yields biomarkers indicative of phenotype that can be used to characterize transitions between health and disease, disease progression and therapeutic responses. The desire to reproducibly detect ever greater numbers of metabolites at ever diminishing levels has naturally nurtured advances in best practice for sample procurement, storage and analysis. Reciprocally, since many of the available extensive clinical archives were established prior to the metabolomics era and were not processed in such an 'ideal' fashion, considerable scepticism has arisen as to their value for metabolomic analysis. Here we have challenged that paradigm. METHODS: We performed proton nuclear magnetic resonance spectroscopy-based metabolomics on blood serum and urine samples from 32 patients representative of a total cohort of 1970 multiple myeloma patients entered into the United Kingdom Medical Research Council Myeloma IX trial. FINDINGS: Using serial paired blood and urine samples we detected metabolite profiles that associated with diagnosis, post-treatment remission and disease progression. These studies identified carnitine and acetylcarnitine as novel potential biomarkers of active disease both at diagnosis and relapse and as a mediator of disease associated pathologies. CONCLUSIONS: These findings show that samples conventionally processed and archived can provide useful metabolomic information that has important implications for understanding the biology of myeloma, discovering new therapies and identifying biomarkers potentially useful in deciding the choice and application of therapy.

  4. Sequential series for nuclear reactions

    International Nuclear Information System (INIS)

    Izumo, Ko

    1975-01-01

    A new time-dependent treatment of nuclear reactions is given, in which the wave function of compound nucleus is expanded by a sequential series of the reaction processes. The wave functions of the sequential series form another complete set of compound nucleus at the limit Δt→0. It is pointed out that the wave function is characterized by the quantities: the number of degrees of freedom of motion n, the period of the motion (Poincare cycle) tsub(n), the delay time t sub(nμ) and the relaxation time tausub(n) to the equilibrium of compound nucleus, instead of the usual quantum number lambda, the energy eigenvalue Esub(lambda) and the total width GAMMAsub(lambda) of resonance levels, respectively. The transition matrix elements and the yields of nuclear reactions also become the functions of time given by the Fourier transform of the usual ones. The Poincare cycles of compound nuclei are compared with the observed correlations among resonance levels, which are about 10 -17 --10 -16 sec for medium and heavy nuclei and about 10 -20 sec for the intermediate resonances. (auth.)

  5. Sequential search leads to faster, more efficient fragment-based de novo protein structure prediction.

    Science.gov (United States)

    de Oliveira, Saulo H P; Law, Eleanor C; Shi, Jiye; Deane, Charlotte M

    2018-04-01

    Most current de novo structure prediction methods randomly sample protein conformations and thus require large amounts of computational resource. Here, we consider a sequential sampling strategy, building on ideas from recent experimental work which shows that many proteins fold cotranslationally. We have investigated whether a pseudo-greedy search approach, which begins sequentially from one of the termini, can improve the performance and accuracy of de novo protein structure prediction. We observed that our sequential approach converges when fewer than 20 000 decoys have been produced, fewer than commonly expected. Using our software, SAINT2, we also compared the run time and quality of models produced in a sequential fashion against a standard, non-sequential approach. Sequential prediction produces an individual decoy 1.5-2.5 times faster than non-sequential prediction. When considering the quality of the best model, sequential prediction led to a better model being produced for 31 out of 41 soluble protein validation cases and for 18 out of 24 transmembrane protein cases. Correct models (TM-Score > 0.5) were produced for 29 of these cases by the sequential mode and for only 22 by the non-sequential mode. Our comparison reveals that a sequential search strategy can be used to drastically reduce computational time of de novo protein structure prediction and improve accuracy. Data are available for download from: http://opig.stats.ox.ac.uk/resources. SAINT2 is available for download from: https://github.com/sauloho/SAINT2. saulo.deoliveira@dtc.ox.ac.uk. Supplementary data are available at Bioinformatics online.

  6. Sequential analysis in neonatal research-systematic review.

    Science.gov (United States)

    Lava, Sebastiano A G; Elie, Valéry; Ha, Phuong Thi Viet; Jacqz-Aigrain, Evelyne

    2018-05-01

    As more new drugs are discovered, traditional designs come at their limits. Ten years after the adoption of the European Paediatric Regulation, we performed a systematic review on the US National Library of Medicine and Excerpta Medica database of sequential trials involving newborns. Out of 326 identified scientific reports, 21 trials were included. They enrolled 2832 patients, of whom 2099 were analyzed: the median number of neonates included per trial was 48 (IQR 22-87), median gestational age was 28.7 (IQR 27.9-30.9) weeks. Eighteen trials used sequential techniques to determine sample size, while 3 used continual reassessment methods for dose-finding. In 16 studies reporting sufficient data, the sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674) with respect to a traditional trial. When the number of neonates finally included in the analysis was considered, the difference became significant: 35 (57%) patients (IQR 10 to 136.5, p = 0.0033). Sequential trial designs have not been frequently used in Neonatology. They might potentially be able to reduce the number of patients in drug trials, although this is not always the case. What is known: • In evaluating rare diseases in fragile populations, traditional designs come at their limits. About 20% of pediatric trials are discontinued, mainly because of recruitment problems. What is new: • Sequential trials involving newborns were infrequently used and only a few (n = 21) are available for analysis. • The sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674).

  7. Exploring the sequential lineup advantage using WITNESS.

    Science.gov (United States)

    Goodsell, Charles A; Gronlund, Scott D; Carlson, Curt A

    2010-12-01

    Advocates claim that the sequential lineup is an improvement over simultaneous lineup procedures, but no formal (quantitatively specified) explanation exists for why it is better. The computational model WITNESS (Clark, Appl Cogn Psychol 17:629-654, 2003) was used to develop theoretical explanations for the sequential lineup advantage. In its current form, WITNESS produced a sequential advantage only by pairing conservative sequential choosing with liberal simultaneous choosing. However, this combination failed to approximate four extant experiments that exhibited large sequential advantages. Two of these experiments became the focus of our efforts because the data were uncontaminated by likely suspect position effects. Decision-based and memory-based modifications to WITNESS approximated the data and produced a sequential advantage. The next step is to evaluate the proposed explanations and modify public policy recommendations accordingly.

  8. A novel antibody–antigen based impedimetric immunosensor for low level detection of HER2 in serum samples of breast cancer patients via modification of a gold nanoparticles decorated multiwall carbon nanotube-ionic liquid electrode

    Energy Technology Data Exchange (ETDEWEB)

    Arkan, Elham [Nano Drug Delivery Research Center, Kermanshah University of Medical Sciences, Kermanshah (Iran, Islamic Republic of); Saber, Reza [Department of Medical Nanotechnology, School of Advanced Medical Technologies, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Research Center for Science and Technology in Medicine, Imam Khomeini Hospital, Tehran (Iran, Islamic Republic of); Karimi, Ziba [Department of Chemistry, Payame Noor University, P.O. Box 19395-3697, Tehran (Iran, Islamic Republic of); Shamsipur, Mojtaba, E-mail: mshamsipur@yahoo.com [Department of Chemistry, Razi University, Kermanshah (Iran, Islamic Republic of)

    2015-05-18

    Highlights: • Design of a novel impedimetric immunosensor for detection of HER2 in serum samples. • Use of a multiwall carbon nanotube-ionic liquid electrode modified with AuNPs as a base. • Immobilization of monoclonal HER2 antibody on AuNPs/MWCILE using 1,6-hexanedithiol as a cross linker. • Achieving linear dynamic range and limit of detection of 10–110 ng mL{sup −1} and 7.4 ng mL{sup −1}, respectively. • Method development and validation and application to assay of HER2 in biological fluids. - Abstract: A highly sensitive impedimetric immunosensor based on a gold nanoparticles/multiwall carbon nanotube-ionic liquid electrode (AuNPs/MW-CILE) was developed for the determination of human epidermal growth factor receptor 2 (HER2). Gold nanoparticles were used to enhance the extent of immobilization and to retain the immunoactivity of the antibody Herceptin on the electrode. Cyclic voltammetry and electrochemical impedance spectroscopy were employed for characterization of various layers coated onto the AuNPs/MW-CILE. The impedance measurements at different steps were based on the charge transfer kinetics of the [Fe(CN){sub 6}]{sup 3−/4−} redox pair. The immobilization of antibody and the corresponding antigen–antibody interaction at the electrode surface altered the interfacial electron transfer. The interactions of antibody with various concentrations of antigen were also monitored via the change of impedance response. The results showed that the charge transfer resistance increases linearly with increasing concentrations of HER2 antigen. The linear range and limit of detection were found as 10–110 ng mL{sup −1} and 7.4 ng mL{sup −1}, respectively. The sensitivity and specificity of the immunosensor were validated. The results showed that the prepared immunosensor is a useful tool for screening of trace amounts of HER2 in serum samples of breast cancer patients.

  9. Sequential lineup presentation: Patterns and policy

    OpenAIRE

    Lindsay, R C L; Mansour, Jamal K; Beaudry, J L; Leach, A-M; Bertrand, M I

    2009-01-01

    Sequential lineups were offered as an alternative to the traditional simultaneous lineup. Sequential lineups reduce incorrect lineup selections; however, the accompanying loss of correct identifications has resulted in controversy regarding adoption of the technique. We discuss the procedure and research relevant to (1) the pattern of results found using sequential versus simultaneous lineups; (2) reasons (theory) for differences in witness responses; (3) two methodological issues; and (4) im...

  10. Effect of cryoablation sequential chemotherapy on patients with advanced non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Shu-Hui Yao

    2016-03-01

    Full Text Available Objective: To evaluate the effect of cryoablation sequential chemotherapy on patients with advanced non-small cell lung cancer. Methods: A total of 39 cases with advanced non-small cell lung cancer who received cryoablation sequential chemotherapy and 39 cases with advanced non-small cell lung cancer who received chemotherapy alone were selected and enrolled in sequential group and control group, disease progression and survival of two groups were followed up, and contents of tumor markers and angiogenesis molecules in serum as well as contents of T-lymphocyte subsets in peripheral blood were detected. Results: Progressionfree survival and median overall survival (mOS of sequential group were longer than those of control group, and cumulative cases of tumor progression at various points in time were significantly less than those of control group (P<0.05; 1 month after treatment, serum tumor markers CEA, CYFRA21-1 and NSE contents, serum angiogenesis molecules PCDGF, VEGF and HDGF contents as well as CD3+CD4-CD8+CD28-T cell content in peripheral blood of sequential group were significantly lower than those of control group (P<0.05, and contents of CD3+CD4+CD8-T cell and CD3+CD4-CD8+CD28+T cell in peripheral blood were higher than those of control group (P<0.05. Conclusions: Cryoablation sequential chemotherapy can improve the prognosis of patients with advanced non-small cell lung cancer, delay disease progression, prolong survival time, inhibit angiogenesis and improve immune function.

  11. The Bacterial Sequential Markov Coalescent.

    Science.gov (United States)

    De Maio, Nicola; Wilson, Daniel J

    2017-05-01

    Bacteria can exchange and acquire new genetic material from other organisms directly and via the environment. This process, known as bacterial recombination, has a strong impact on the evolution of bacteria, for example, leading to the spread of antibiotic resistance across clades and species, and to the avoidance of clonal interference. Recombination hinders phylogenetic and transmission inference because it creates patterns of substitutions (homoplasies) inconsistent with the hypothesis of a single evolutionary tree. Bacterial recombination is typically modeled as statistically akin to gene conversion in eukaryotes, i.e. , using the coalescent with gene conversion (CGC). However, this model can be very computationally demanding as it needs to account for the correlations of evolutionary histories of even distant loci. So, with the increasing popularity of whole genome sequencing, the need has emerged for a faster approach to model and simulate bacterial genome evolution. We present a new model that approximates the coalescent with gene conversion: the bacterial sequential Markov coalescent (BSMC). Our approach is based on a similar idea to the sequential Markov coalescent (SMC)-an approximation of the coalescent with crossover recombination. However, bacterial recombination poses hurdles to a sequential Markov approximation, as it leads to strong correlations and linkage disequilibrium across very distant sites in the genome. Our BSMC overcomes these difficulties, and shows a considerable reduction in computational demand compared to the exact CGC, and very similar patterns in simulated data. We implemented our BSMC model within new simulation software FastSimBac. In addition to the decreased computational demand compared to previous bacterial genome evolution simulators, FastSimBac provides more general options for evolutionary scenarios, allowing population structure with migration, speciation, population size changes, and recombination hotspots. FastSimBac is

  12. Serum ferritin

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Diaz de Domingo, N.B.; Lazarowski, A.

    1981-01-01

    Serum ferritin (SF) concentration as determined by the immunoradiometric method allows the direct measurement of a fraction of the body ferritin pool. In normal subjects, SF is an excellent index of body iron stores. In certain conditions associated with increased ferritin synthesis (such as liver disease, inflammation, malignancy, chronic disorders, ineffective erythropoiesis, or during ferrotherapy), SF may not accurately reflect body iron stores. In hyposideremic anemias SF concentration permits to differentiate those due to iron deficiency from those due to chronic disorders. With a good assay quality, subnormal SF levels are incontrovertible in the diagnosis of iron deficiency. SF determination has been investigated as possible tumor marker. When performed in combination with the alpha-fetoprotein assay, SF enhances the specificity of serodiagnosis of hepatoma. SF results must be interpreted bearing in mind the possible participation of circumstances that i) modify the body iron stores and ii) lead to increased ferritin synthesis. (author) [es

  13. Biased lineups: sequential presentation reduces the problem.

    Science.gov (United States)

    Lindsay, R C; Lea, J A; Nosworthy, G J; Fulford, J A; Hector, J; LeVan, V; Seabrook, C

    1991-12-01

    Biased lineups have been shown to increase significantly false, but not correct, identification rates (Lindsay, Wallbridge, & Drennan, 1987; Lindsay & Wells, 1980; Malpass & Devine, 1981). Lindsay and Wells (1985) found that sequential lineup presentation reduced false identification rates, presumably by reducing reliance on relative judgment processes. Five staged-crime experiments were conducted to examine the effect of lineup biases and sequential presentation on eyewitness recognition accuracy. Sequential lineup presentation significantly reduced false identification rates from fair lineups as well as from lineups biased with regard to foil similarity, instructions, or witness attire, and from lineups biased in all of these ways. The results support recommendations that police present lineups sequentially.

  14. Immediate Sequential Bilateral Cataract Surgery

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Erngaard, Ditte

    2015-01-01

    The aim of the present systematic review was to examine the benefits and harms associated with immediate sequential bilateral cataract surgery (ISBCS) with specific emphasis on the rate of complications, postoperative anisometropia, and subjective visual function in order to formulate evidence......-based national Danish guidelines for cataract surgery. A systematic literature review in PubMed, Embase, and Cochrane central databases identified three randomized controlled trials that compared outcome in patients randomized to ISBCS or bilateral cataract surgery on two different dates. Meta-analyses were...... performed using the Cochrane Review Manager software. The quality of the evidence was assessed using the GRADE method (Grading of Recommendation, Assessment, Development, and Evaluation). We did not find any difference in the risk of complications or visual outcome in patients randomized to ISBCS or surgery...

  15. Random and cooperative sequential adsorption

    Science.gov (United States)

    Evans, J. W.

    1993-10-01

    Irreversible random sequential adsorption (RSA) on lattices, and continuum "car parking" analogues, have long received attention as models for reactions on polymer chains, chemisorption on single-crystal surfaces, adsorption in colloidal systems, and solid state transformations. Cooperative generalizations of these models (CSA) are sometimes more appropriate, and can exhibit richer kinetics and spatial structure, e.g., autocatalysis and clustering. The distribution of filled or transformed sites in RSA and CSA is not described by an equilibrium Gibbs measure. This is the case even for the saturation "jammed" state of models where the lattice or space cannot fill completely. However exact analysis is often possible in one dimension, and a variety of powerful analytic methods have been developed for higher dimensional models. Here we review the detailed understanding of asymptotic kinetics, spatial correlations, percolative structure, etc., which is emerging for these far-from-equilibrium processes.

  16. Evaluation of growth performance, serum biochemistry and haematological parameters on broiler birds fed with raw and processed samples of Entada scandens, Canavalia gladiata and Canavalia ensiformis seed meal as an alternative protein source.

    Science.gov (United States)

    Sasipriya, Gopalakrishnan; Siddhuraju, Perumal

    2013-03-01

    The experiment was carried out to investigate the inclusion of underutilised legumes, Entada scandens, Canavalia gladiata and Canavalia ensiformis, seed meal in soybean-based diet in broilers. The utilisation of these wild legumes is limited by the presence of antinutrient compounds. Processing methods like soaking followed by autoclaving in sodium bicarbonate solution in E. scandens and C. gladiata and soaking followed by autoclaving in ash solution in C. ensiformis were adopted. The proximate composition of raw and processed samples of E. scandens, C. gladiata and C. ensiformis were determined. The protein content was enhanced in processed sample of E. scandens (46 %) and C. ensiformis (16 %). This processing method had reduced the maximum number of antinutrients such as tannins (10-100 %), trypsin inhibitor activity (99 %), chymotrypsin inhibitor activity (72-100 %), canavanine (60-62 %), amylase inhibitor activity (73-100 %), saponins (78-92 %), phytic acid (19-40 %) and lectins. Hence, the raw samples at 15 % and processed samples at 15 and 30 % were replaced with soybean protein in commercial broiler diet respectively. Birds fed with 30 % processed samples of E. scandens, C. gladiata and C. ensiformis showed significantly similar results of growth performance, carcass characteristics, organ weight, haematological parameters and serum biochemical parameters (cholesterol, protein, bilirubin, albumin, globulin and liver and kidney function parameters) without any adverse effects after 42 days of supplementation. The proper utilisation of these underutilised legumes may act as an alternative protein ingredient in poultry diets.

  17. Sequential sampling, magnitude estimation, and the wisdom of crowds

    DEFF Research Database (Denmark)

    Nash, Ulrik W.

    2017-01-01

    in the wisdom of crowds indicated by judgment distribution skewness. The present study reports findings from an experiment on magnitude estimation and supports these predictions. The study moreover demonstrates that systematic errors by groups of people can be corrected using information about the judgment...

  18. Likelihood ratio sequential sampling models of recognition memory.

    Science.gov (United States)

    Osth, Adam F; Dennis, Simon; Heathcote, Andrew

    2017-02-01

    The mirror effect - a phenomenon whereby a manipulation produces opposite effects on hit and false alarm rates - is benchmark regularity of recognition memory. A likelihood ratio decision process, basing recognition on the relative likelihood that a stimulus is a target or a lure, naturally predicts the mirror effect, and so has been widely adopted in quantitative models of recognition memory. Glanzer, Hilford, and Maloney (2009) demonstrated that likelihood ratio models, assuming Gaussian memory strength, are also capable of explaining regularities observed in receiver-operating characteristics (ROCs), such as greater target than lure variance. Despite its central place in theorising about recognition memory, however, this class of models has not been tested using response time (RT) distributions. In this article, we develop a linear approximation to the likelihood ratio transformation, which we show predicts the same regularities as the exact transformation. This development enabled us to develop a tractable model of recognition-memory RT based on the diffusion decision model (DDM), with inputs (drift rates) provided by an approximate likelihood ratio transformation. We compared this "LR-DDM" to a standard DDM where all targets and lures receive their own drift rate parameters. Both were implemented as hierarchical Bayesian models and applied to four datasets. Model selection taking into account parsimony favored the LR-DDM, which requires fewer parameters than the standard DDM but still fits the data well. These results support log-likelihood based models as providing an elegant explanation of the regularities of recognition memory, not only in terms of choices made but also in terms of the times it takes to make them. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Optimisation of beryllium-7 gamma analysis following BCR sequential extraction

    International Nuclear Information System (INIS)

    Taylor, A.; Blake, W.H.; Keith-Roach, M.J.

    2012-01-01

    Graphical abstract: Showing decrease in analytical uncertainty using the optimal (combined preconcentrated sample extract) method. nv (no value) where extract activities were 7 Be geochemical behaviour is required to support tracer studies. ► Sequential extraction with natural 7 Be returns high analytical uncertainties. ► Preconcentrating extracts from a large sample mass improved analytical uncertainty. ► This optimised method can be readily employed in studies using low activity samples. - Abstract: The application of cosmogenic 7 Be as a sediment tracer at the catchment-scale requires an understanding of its geochemical associations in soil to underpin the assumption of irreversible adsorption. Sequential extractions offer a readily accessible means of determining the associations of 7 Be with operationally defined soil phases. However, the subdivision of the low activity concentrations of fallout 7 Be in soils into geochemical fractions can introduce high gamma counting uncertainties. Extending analysis time significantly is not always an option for batches of samples, owing to the on-going decay of 7 Be (t 1/2 = 53.3 days). Here, three different methods of preparing and quantifying 7 Be extracted using the optimised BCR three-step scheme have been evaluated and compared with a focus on reducing analytical uncertainties. The optimal method involved carrying out the BCR extraction in triplicate, sub-sampling each set of triplicates for stable Be analysis before combining each set and coprecipitating the 7 Be with metal oxyhydroxides to produce a thin source for gamma analysis. This method was applied to BCR extractions of natural 7 Be in four agricultural soils. The approach gave good counting statistics from a 24 h analysis period (∼10% (2σ) where extract activity >40% of total activity) and generated statistically useful sequential extraction profiles. Total recoveries of 7 Be fell between 84 and 112%. The stable Be data demonstrated that the

  20. Trial Sequential Methods for Meta-Analysis

    Science.gov (United States)

    Kulinskaya, Elena; Wood, John

    2014-01-01

    Statistical methods for sequential meta-analysis have applications also for the design of new trials. Existing methods are based on group sequential methods developed for single trials and start with the calculation of a required information size. This works satisfactorily within the framework of fixed effects meta-analysis, but conceptual…

  1. Formation of InN phase by sequential ion implantation

    International Nuclear Information System (INIS)

    Santhana Raman, P.; Ravichandran, V.; Nair, K.G.M.; Kesavamoorthy, R.; Kalavathi, S.; Panigrahi, B.K.; Dhara, S.

    2006-01-01

    Formation of InN phase by sequentially implanting nitrogen on indium implanted silica was demonstrated. The growth of embedded InN phase on as-implanted and post-implantation annealed sample was studied using Glancing Incidence X-Ray Diffraction (GIXRD) and Raman spectroscopy. Existence of both cubic and hexagonal phases of InN was observed. Results of irradiation induced ripening of In nanoclusters due to N + ion implantation was also studied. (author)

  2. Sequential lineup laps and eyewitness accuracy.

    Science.gov (United States)

    Steblay, Nancy K; Dietrich, Hannah L; Ryan, Shannon L; Raczynski, Jeanette L; James, Kali A

    2011-08-01

    Police practice of double-blind sequential lineups prompts a question about the efficacy of repeated viewings (laps) of the sequential lineup. Two laboratory experiments confirmed the presence of a sequential lap effect: an increase in witness lineup picks from first to second lap, when the culprit was a stranger. The second lap produced more errors than correct identifications. In Experiment 2, lineup diagnosticity was significantly higher for sequential lineup procedures that employed a single versus double laps. Witnesses who elected to view a second lap made significantly more errors than witnesses who chose to stop after one lap or those who were required to view two laps. Witnesses with prior exposure to the culprit did not exhibit a sequential lap effect.

  3. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.

    2014-12-15

    This paper considers multi-agent sequential hypothesis testing and presents a framework for strategic learning in sequential games with explicit consideration of both temporal and spatial coordination. The associated Bayes risk functions explicitly incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well-defined value functions with respect to (a) the belief states for the case of conditional independent private noisy measurements that are also assumed to be independent identically distributed over time, and (b) the information states for the case of correlated private noisy measurements. A sequential investment game of strategic coordination and delay is also discussed as an application of the proposed strategic learning rules.

  4. Sequential Product of Quantum Effects: An Overview

    Science.gov (United States)

    Gudder, Stan

    2010-12-01

    This article presents an overview for the theory of sequential products of quantum effects. We first summarize some of the highlights of this relatively recent field of investigation and then provide some new results. We begin by discussing sequential effect algebras which are effect algebras endowed with a sequential product satisfying certain basic conditions. We then consider sequential products of (discrete) quantum measurements. We next treat transition effect matrices (TEMs) and their associated sequential product. A TEM is a matrix whose entries are effects and whose rows form quantum measurements. We show that TEMs can be employed for the study of quantum Markov chains. Finally, we prove some new results concerning TEMs and vector densities.

  5. A Bayesian sequential design using alpha spending function to control type I error.

    Science.gov (United States)

    Zhu, Han; Yu, Qingzhao

    2017-10-01

    We propose in this article a Bayesian sequential design using alpha spending functions to control the overall type I error in phase III clinical trials. We provide algorithms to calculate critical values, power, and sample sizes for the proposed design. Sensitivity analysis is implemented to check the effects from different prior distributions, and conservative priors are recommended. We compare the power and actual sample sizes of the proposed Bayesian sequential design with different alpha spending functions through simulations. We also compare the power of the proposed method with frequentist sequential design using the same alpha spending function. Simulations show that, at the same sample size, the proposed method provides larger power than the corresponding frequentist sequential design. It also has larger power than traditional Bayesian sequential design which sets equal critical values for all interim analyses. When compared with other alpha spending functions, O'Brien-Fleming alpha spending function has the largest power and is the most conservative in terms that at the same sample size, the null hypothesis is the least likely to be rejected at early stage of clinical trials. And finally, we show that adding a step of stop for futility in the Bayesian sequential design can reduce the overall type I error and reduce the actual sample sizes.

  6. Sequential Scintigraphy in Renal Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Winkel, K. zum; Harbst, H.; Schenck, P.; Franz, H. E.; Ritz, E.; Roehl, L.; Ziegler, M.; Ammann, W.; Maier-Borst, W. [Institut Fuer Nuklearmedizin, Deutsches Krebsforschungszentrum, Heidelberg, Federal Republic of Germany (Germany)

    1969-05-15

    Based on experience gained from more than 1600 patients with proved or suspected kidney diseases and on results on extended studies with dogs, sequential scintigraphy was performed after renal transplantation in dogs. After intravenous injection of 500 {mu}Ci. {sup 131}I-Hippuran scintiphotos were taken during the first minute with an exposure time of 15 sec each and thereafter with an exposure of 2 min up to at least 16 min.. Several examinations were evaluated digitally. 26 examinations were performed on 11 dogs with homotransplanted kidneys. Immediately after transplantation the renal function was almost normal arid the bladder was filled in due time. At the beginning of rejection the initial uptake of radioactive Hippuran was reduced. The intrarenal transport became delayed; probably the renal extraction rate decreased. Corresponding to the development of an oedema in the transplant the uptake area increased in size. In cases of thrombosis of the main artery there was no evidence of any uptake of radioactivity in the transplant. Similar results were obtained in 41 examinations on 15 persons. Patients with postoperative anuria due to acute tubular necrosis showed still some uptake of radioactivity contrary to those with thrombosis of the renal artery, where no uptake was found. In cases of rejection the most frequent signs were a reduced initial uptake and a delayed intrarenal transport of radioactive Hippuran. Infarction could be detected by a reduced uptake in distinct areas of the transplant. (author)

  7. Sequential provisional implant prosthodontics therapy.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Schnader, Yale E; Shapiro, Herbert J

    2012-01-01

    The fabrication and long-term use of first- and second-stage provisional implant prostheses is critical to create a favorable prognosis for function and esthetics of a fixed-implant supported prosthesis. The fixed metal and acrylic resin cemented first-stage prosthesis, as reviewed in Part I, is needed for prevention of adjacent and opposing tooth movement, pressure on the implant site as well as protection to avoid micromovement of the freshly placed implant body. The second-stage prosthesis, reviewed in Part II, should be used following implant uncovering and abutment installation. The patient wears this provisional prosthesis until maturation of the bone and healing of soft tissues. The second-stage provisional prosthesis is also a fail-safe mechanism for possible early implant failures and also can be used with late failures and/or for the necessity to repair the definitive prosthesis. In addition, the screw-retained provisional prosthesis is used if and when an implant requires removal or other implants are to be placed as in a sequential approach. The creation and use of both first- and second-stage provisional prostheses involve a restorative dentist, dental technician, surgeon, and patient to work as a team. If the dentist alone cannot do diagnosis and treatment planning, surgery, and laboratory techniques, he or she needs help by employing the expertise of a surgeon and a laboratory technician. This team approach is essential for optimum results.

  8. Trial Sequential Analysis in systematic reviews with meta-analysis

    Directory of Open Access Journals (Sweden)

    Jørn Wetterslev

    2017-03-01

    Full Text Available Abstract Background Most meta-analyses in systematic reviews, including Cochrane ones, do not have sufficient statistical power to detect or refute even large intervention effects. This is why a meta-analysis ought to be regarded as an interim analysis on its way towards a required information size. The results of the meta-analyses should relate the total number of randomised participants to the estimated required meta-analytic information size accounting for statistical diversity. When the number of participants and the corresponding number of trials in a meta-analysis are insufficient, the use of the traditional 95% confidence interval or the 5% statistical significance threshold will lead to too many false positive conclusions (type I errors and too many false negative conclusions (type II errors. Methods We developed a methodology for interpreting meta-analysis results, using generally accepted, valid evidence on how to adjust thresholds for significance in randomised clinical trials when the required sample size has not been reached. Results The Lan-DeMets trial sequential monitoring boundaries in Trial Sequential Analysis offer adjusted confidence intervals and restricted thresholds for statistical significance when the diversity-adjusted required information size and the corresponding number of required trials for the meta-analysis have not been reached. Trial Sequential Analysis provides a frequentistic approach to control both type I and type II errors. We define the required information size and the corresponding number of required trials in a meta-analysis and the diversity (D2 measure of heterogeneity. We explain the reasons for using Trial Sequential Analysis of meta-analysis when the actual information size fails to reach the required information size. We present examples drawn from traditional meta-analyses using unadjusted naïve 95% confidence intervals and 5% thresholds for statistical significance. Spurious conclusions in

  9. Sequential boundaries approach in clinical trials with unequal allocation ratios

    Directory of Open Access Journals (Sweden)

    Ayatollahi Seyyed

    2006-01-01

    Full Text Available Abstract Background In clinical trials, both unequal randomization design and sequential analyses have ethical and economic advantages. In the single-stage-design (SSD, however, if the sample size is not adjusted based on unequal randomization, the power of the trial will decrease, whereas with sequential analysis the power will always remain constant. Our aim was to compare sequential boundaries approach with the SSD when the allocation ratio (R was not equal. Methods We evaluated the influence of R, the ratio of the patients in experimental group to the standard group, on the statistical properties of two-sided tests, including the two-sided single triangular test (TT, double triangular test (DTT and SSD by multiple simulations. The average sample size numbers (ASNs and power (1-β were evaluated for all tests. Results Our simulation study showed that choosing R = 2 instead of R = 1 increases the sample size of SSD by 12% and the ASN of the TT and DTT by the same proportion. Moreover, when R = 2, compared to the adjusted SSD, using the TT or DTT allows to retrieve the well known reductions of ASN observed when R = 1, compared to SSD. In addition, when R = 2, compared to SSD, using the TT and DTT allows to obtain smaller reductions of ASN than when R = 1, but maintains the power of the test to its planned value. Conclusion This study indicates that when the allocation ratio is not equal among the treatment groups, sequential analysis could indeed serve as a compromise between ethicists, economists and statisticians.

  10. Sequential analysis of biochemical markers of bone resorption and bone densitometry in multiple myeloma

    DEFF Research Database (Denmark)

    Abildgaard, Niels; Brixen, K; Eriksen, E.F

    2004-01-01

    BACKGROUND AND OBJECTIVES: Bone lesions often occur in multiple myeloma (MM), but no tests have proven useful in identifying patients with increased risk. Bone marker assays and bone densitometry are non-invasive methods that can be used repeatedly at low cost. This study was performed to evaluate...... 6 weeks, DEXA-scans performed every 3 months, and skeletal radiographs were done every 6 months as well as when indicated. RESULTS: Serum ICTP and urinary NTx were predictive of progressive bone events. Markers of bone formation, bone mineral density assessments, and M component measurements were...... changes, and our data do not support routine use of sequential DEXA-scans. However, lumbar DEXA-scans at diagnosis can identify patients with increased risk of early vertebral collapses. Sequential analyses of serum ICTP and urinary NTx are useful for monitoring bone damage....

  11. Optimisation of beryllium-7 gamma analysis following BCR sequential extraction

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, A. [Plymouth University, School of Geography, Earth and Environmental Sciences, 8 Kirkby Place, Plymouth PL4 8AA (United Kingdom); Blake, W.H., E-mail: wblake@plymouth.ac.uk [Plymouth University, School of Geography, Earth and Environmental Sciences, 8 Kirkby Place, Plymouth PL4 8AA (United Kingdom); Keith-Roach, M.J. [Plymouth University, School of Geography, Earth and Environmental Sciences, 8 Kirkby Place, Plymouth PL4 8AA (United Kingdom); Kemakta Konsult, Stockholm (Sweden)

    2012-03-30

    Graphical abstract: Showing decrease in analytical uncertainty using the optimal (combined preconcentrated sample extract) method. nv (no value) where extract activities were Sequential extraction with natural {sup 7}Be returns high analytical uncertainties. Black-Right-Pointing-Pointer Preconcentrating extracts from a large sample mass improved analytical uncertainty. Black-Right-Pointing-Pointer This optimised method can be readily employed in studies using low activity samples. - Abstract: The application of cosmogenic {sup 7}Be as a sediment tracer at the catchment-scale requires an understanding of its geochemical associations in soil to underpin the assumption of irreversible adsorption. Sequential extractions offer a readily accessible means of determining the associations of {sup 7}Be with operationally defined soil phases. However, the subdivision of the low activity concentrations of fallout {sup 7}Be in soils into geochemical fractions can introduce high gamma counting uncertainties. Extending analysis time significantly is not always an option for batches of samples, owing to the on-going decay of {sup 7}Be (t{sub 1/2} = 53.3 days). Here, three different methods of preparing and quantifying {sup 7}Be extracted using the optimised BCR three-step scheme have been evaluated and compared with a focus on reducing analytical uncertainties. The optimal method involved carrying out the BCR extraction in triplicate, sub-sampling each set of triplicates for stable Be analysis before combining each set and coprecipitating the {sup 7}Be with metal oxyhydroxides to produce a thin source for gamma analysis. This method was applied to BCR extractions of natural {sup 7}Be in four agricultural soils. The approach gave good counting statistics from a 24 h analysis period ({approx}10% (2

  12. Tradable permit allocations and sequential choice

    Energy Technology Data Exchange (ETDEWEB)

    MacKenzie, Ian A. [Centre for Economic Research, ETH Zuerich, Zurichbergstrasse 18, 8092 Zuerich (Switzerland)

    2011-01-15

    This paper investigates initial allocation choices in an international tradable pollution permit market. For two sovereign governments, we compare allocation choices that are either simultaneously or sequentially announced. We show sequential allocation announcements result in higher (lower) aggregate emissions when announcements are strategic substitutes (complements). Whether allocation announcements are strategic substitutes or complements depends on the relationship between the follower's damage function and governments' abatement costs. When the marginal damage function is relatively steep (flat), allocation announcements are strategic substitutes (complements). For quadratic abatement costs and damages, sequential announcements provide a higher level of aggregate emissions. (author)

  13. Sequential Generalized Transforms on Function Space

    Directory of Open Access Journals (Sweden)

    Jae Gil Choi

    2013-01-01

    Full Text Available We define two sequential transforms on a function space Ca,b[0,T] induced by generalized Brownian motion process. We then establish the existence of the sequential transforms for functionals in a Banach algebra of functionals on Ca,b[0,T]. We also establish that any one of these transforms acts like an inverse transform of the other transform. Finally, we give some remarks about certain relations between our sequential transforms and other well-known transforms on Ca,b[0,T].

  14. Ratiometric Phosphorescent Probe for Thallium in Serum, Water, and Soil Samples Based on Long-Lived, Spectrally Resolved, Mn-Doped ZnSe Quantum Dots and Carbon Dots.

    Science.gov (United States)

    Lu, Xiaomei; Zhang, Jinyi; Xie, Ya-Ni; Zhang, Xinfeng; Jiang, Xiaoming; Hou, Xiandeng; Wu, Peng

    2018-02-20

    Thallium (Tl) is an extremely toxic heavy metal and exists in very low concentrations in the environment, but its sensing is largely underexplored as compared to its neighboring elements in the periodic table (especially mercury and lead). In this work, we developed a ratiometric phosphorescent nanoprobe for thallium detection based on Mn-doped ZnSe quantum dots (QDs) and water-soluble carbon dots (C-dots). Upon excitation with 360 nm, Mn-doped ZnSe QDs and C-dots can emit long-lived and spectrally resolved phosphorescence at 580 and 440 nm, respectively. In the presence of thallium, the phosphorescence emission from Mn-doped ZnSe QDs could be selectively quenched, while that from C-dots retained unchanged. Therefore, a ratiometric phosphorescent probe was thus developed, which can eliminate the potential influence from both background fluorescence and other analyte-independent external environment factors. Several other heavy metal ions caused interferences to thallium detection but could be efficiently masked with EDTA. The proposed method offered a detection limit of 1 μg/L, which is among the most sensitive probes ever reported. Successful application of this method for thallium detection in biological serum as well as in environmental water and soil samples was demonstrated.

  15. Automated extraction of lysergic acid diethylamide (LSD) and N-demethyl-LSD from blood, serum, plasma, and urine samples using the Zymark RapidTrace with LC/MS/MS confirmation.

    Science.gov (United States)

    de Kanel, J; Vickery, W E; Waldner, B; Monahan, R M; Diamond, F X

    1998-05-01

    A forensic procedure for the quantitative confirmation of lysergic acid diethylamide (LSD) and the qualitative confirmation of its metabolite, N-demethyl-LSD, in blood, serum, plasma, and urine samples is presented. The Zymark RapidTrace was used to perform fully automated solid-phase extractions of all specimen types. After extract evaporation, confirmations were performed using liquid chromatography (LC) followed by positive electrospray ionization (ESI+) mass spectrometry/mass spectrometry (MS/MS) without derivatization. Quantitation of LSD was accomplished using LSD-d3 as an internal standard. The limit of quantitation (LOQ) for LSD was 0.05 ng/mL. The limit of detection (LOD) for both LSD and N-demethyl-LSD was 0.025 ng/mL. The recovery of LSD was greater than 95% at levels of 0.1 ng/mL and 2.0 ng/mL. For LSD at 1.0 ng/mL, the within-run and between-run (different day) relative standard deviation (RSD) was 2.2% and 4.4%, respectively.

  16. Versatile lipid profiling by liquid chromatography-high resolution mass spectrometry using all ion fragmentation and polarity switching. Preliminary application for serum samples phenotyping related to canine mammary cancer.

    Science.gov (United States)

    Gallart-Ayala, H; Courant, F; Severe, S; Antignac, J-P; Morio, F; Abadie, J; Le Bizec, B

    2013-09-24

    Lipids represent an extended class of substances characterized by such high variety and complexity that makes their unified analyses by liquid chromatography coupled to either high resolution or tandem mass spectrometry (LC-HRMS or LC-MS/MS) a real challenge. In the present study, a new versatile methodology associating ultra high performance liquid chromatography coupled to high resolution tandem mass spectrometry (UHPLC-HRMS/MS) have been developed for a comprehensive analysis of lipids. The use of polarity switching and "all ion fragmentation" (AIF) have been two action levels particularly exploited to finally permit the detection and identification of a multi-class and multi-analyte extended range of lipids in a single run. For identification purposes, both higher energy collision dissociation (HCD) and in-source CID (collision induced dissociation) fragmentation were evaluated in order to obtain information about the precursor and product ions in the same spectra. This approach provides both class-specific and lipid-specific fragments, enhancing lipid identification. Finally, the developed method was applied for differential phenotyping of serum samples collected from pet dogs developing spontaneous malignant mammary tumors and health controls. A biological signature associated with the presence of cancer was then successfully revealed from this lipidome analysis, which required to be further investigated and confirmed at larger scale. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Sequential acquisition of mutations in myelodysplastic syndromes.

    Science.gov (United States)

    Makishima, Hideki

    2017-01-01

    Recent progress in next-generation sequencing technologies allows us to discover frequent mutations throughout the coding regions of myelodysplastic syndromes (MDS), potentially providing us with virtually a complete spectrum of driver mutations in this disease. As shown by many study groups these days, such driver mutations are acquired in a gene-specific fashion. For instance, DDX41 mutations are observed in germline cells long before MDS presentation. In blood samples from healthy elderly individuals, somatic DNMT3A and TET2 mutations are detected as age-related clonal hematopoiesis and are believed to be a risk factor for hematological neoplasms. In MDS, mutations of genes such as NRAS and FLT3, designated as Type-1 genes, may be significantly associated with leukemic evolution. Another type (Type-2) of genes, including RUNX1 and GATA2, are related to progression from low-risk to high-risk MDS. Overall, various driver mutations are sequentially acquired in MDS, at a specific time, in either germline cells, normal hematopoietic cells, or clonal MDS cells.

  18. Simplifying the human serum proteome for discriminating patients with bipolar disorder of other psychiatry conditions.

    Science.gov (United States)

    de Jesus, Jemmyson Romário; Galazzi, Rodrigo Moretto; de Lima, Tatiani Brenelli; Banzato, Cláudio Eduardo Muller; de Almeida Lima E Silva, Luiz Fernando; de Rosalmeida Dantas, Clarissa; Gozzo, Fábio Cézar; Arruda, Marco Aurélio Zezzi

    2017-12-01

    An exploratory analysis using proteomic strategies in blood serum of patients with bipolar disorder (BD), and with other psychiatric conditions such as Schizophrenia (SCZ), can provide a better understanding of this disorder, as well as their discrimination based on their proteomic profile. The proteomic profile of blood serum samples obtained from patients with BD using lithium or other drugs (N=14), healthy controls, including non-family (HCNF; N=3) and family (HCF; N=9), patients with schizophrenia (SCZ; N=23), and patients using lithium for other psychiatric conditions (OD; N=4) were compared. Four methods for simplifying the serum samples proteome were evaluated for both removing the most abundant proteins and for enriching those of lower-abundance: protein depletion with acetonitrile (ACN), dithiothreitol (DTT), sequential depletion using DTT and ACN, and protein equalization using commercial ProteoMiner® kit (PM). For proteomic evaluation, 2-D DIGE and nanoLC-MS/MS analysis were employed. PM method was the best strategy for removing proteins of high abundance. Through 2-D DIGE gel image comparison, 37 protein spots were found differentially abundant (p<0.05, Student's t-test), which exhibited ≥2.0-fold change of the average value of normalized spot intensities in the serum of SCZ, BD and OD patients compared to subject controls (HCF and HCNF). From these spots detected, 13 different proteins were identified: ApoA1, ApoE, ApoC3, ApoA4, Samp, SerpinA1, TTR, IgK, Alb, VTN, TR, C4A and C4B. Proteomic analysis allowed the discrimination of patients with BD from patients with other mental disorders, such as SCZ. The findings in this exploratory study may also contribute for better understanding the pathophysiology of these disorders and finding potential serum biomarkers for these conditions. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Sequential function approximation on arbitrarily distributed point sets

    Science.gov (United States)

    Wu, Kailiang; Xiu, Dongbin

    2018-02-01

    We present a randomized iterative method for approximating unknown function sequentially on arbitrary point set. The method is based on a recently developed sequential approximation (SA) method, which approximates a target function using one data point at each step and avoids matrix operations. The focus of this paper is on data sets with highly irregular distribution of the points. We present a nearest neighbor replacement (NNR) algorithm, which allows one to sample the irregular data sets in a near optimal manner. We provide mathematical justification and error estimates for the NNR algorithm. Extensive numerical examples are also presented to demonstrate that the NNR algorithm can deliver satisfactory convergence for the SA method on data sets with high irregularity in their point distributions.

  20. Efficacy of premixed versus sequential administration of ...

    African Journals Online (AJOL)

    sequential administration in separate syringes on block characteristics, haemodynamic parameters, side effect profile and postoperative analgesic requirement. Trial design: This was a prospective, randomised clinical study. Method: Sixty orthopaedic patients scheduled for elective lower limb surgery under spinal ...

  1. Structural Consistency, Consistency, and Sequential Rationality.

    OpenAIRE

    Kreps, David M; Ramey, Garey

    1987-01-01

    Sequential equilibria comprise consistent beliefs and a sequentially ra tional strategy profile. Consistent beliefs are limits of Bayes ratio nal beliefs for sequences of strategies that approach the equilibrium strategy. Beliefs are structurally consistent if they are rationaliz ed by some single conjecture concerning opponents' strategies. Consis tent beliefs are not necessarily structurally consistent, notwithstan ding a claim by Kreps and Robert Wilson (1982). Moreover, the spirit of stru...

  2. Serum bicarbonate and dehydration severity in gastroenteritis

    OpenAIRE

    Narchi, H.

    1998-01-01

    The concentration of bicarbonate was measured in serum samples from 106 children with gastroenteritis and dehydration. A concentration less than 22 mmol/l was more common in children with severe dehydration, but the magnitude of bicarbonate reduction was not significantly different with increasing degrees of dehydration. Doctors should not rely on the serum bicarbonate concentration when assessing fluid deficit.



  3. Sequential extraction applied to Peruibe black mud, SP, Brazil

    International Nuclear Information System (INIS)

    Torrecilha, Jefferson Koyaishi

    2014-01-01

    The Peruibe Black mud is used in therapeutic treatments such as psoriasis, peripheral dermatitis, acne and seborrhoea, as well as in the treatment of myalgia, arthritis, rheumatism and non-articular processes. Likewise other medicinal clays, it may not be free from possible adverse health effects due to possible hazardous minerals leading to respiratory system occurrences and other effects, caused by the presence of toxic elements. Once used for therapeutic purposes, any given material should be fully characterized and thus samples of Peruibe black mud were analyzed to determine physical and chemical properties: moisture content, organic matter and loss on ignition; pH, particle size, cation exchange capacity and swelling index. The elemental composition was determined by Neutron Activation Analysis, Atomic Absorption Graphite Furnace and X-ray fluorescence; the mineralogical composition was determined by X-ray diffraction. Another tool widely used to evaluate the behavior of trace elements, in various environmental matrices, is the sequential extraction. Thus, a sequential extraction procedure was applied to fractionate the mud in specific geochemical forms and verify how and how much of the elements may be contained in it. Considering the several sequential extraction procedures, BCR-701 method (Community Bureau of Reference) was used since it is considered the most reproducible among them. A simple extraction with an artificial sweat was, also, applied in order to verify which components are potentially available for absorption by the patient skin during the topical treatment. The results indicated that the mud is basically composed by a silty-clay material, rich in organic matter and with good cation exchange capacity. There were no significant variations in mineralogy and elemental composition of both, in natura and mature mud forms. The analysis by sequential extraction and by simple extraction indicated that the elements possibly available in larger

  4. Mean-Variance-Validation Technique for Sequential Kriging Metamodels

    International Nuclear Information System (INIS)

    Lee, Tae Hee; Kim, Ho Sung

    2010-01-01

    The rigorous validation of the accuracy of metamodels is an important topic in research on metamodel techniques. Although a leave-k-out cross-validation technique involves a considerably high computational cost, it cannot be used to measure the fidelity of metamodels. Recently, the mean 0 validation technique has been proposed to quantitatively determine the accuracy of metamodels. However, the use of mean 0 validation criterion may lead to premature termination of a sampling process even if the kriging model is inaccurate. In this study, we propose a new validation technique based on the mean and variance of the response evaluated when sequential sampling method, such as maximum entropy sampling, is used. The proposed validation technique is more efficient and accurate than the leave-k-out cross-validation technique, because instead of performing numerical integration, the kriging model is explicitly integrated to accurately evaluate the mean and variance of the response evaluated. The error in the proposed validation technique resembles a root mean squared error, thus it can be used to determine a stop criterion for sequential sampling of metamodels

  5. [Clinical study on the treatment of acute paraquat poisoning with sequential whole gastric and bowel irrigation].

    Science.gov (United States)

    Zhao, Bo; Dai, Jingbin; Li, Jun; Xiao, Lei; Sun, Baoquan; Liu, Naizheng; Zhang, Yanmin; Jian, Xiangdong

    2015-03-01

    To explore the clinical efficacy of early application of sequential gastrointestinal lavage in patients with acute paraquat poisoning by analyzing the clinical data of 97 patients. A total of 97 eligible patients with acute paraquat poisoning were divided into conventional treatment group (n = 48) and sequential treatment group (n = 49). The conventional treatment group received routine gastric lavage with water. Then 30 g of montmorillonite powder, 30 g of activated charcoal, and mannitol were given to remove intestinal toxins once a day for five days. The sequential treatment group received 60 g of montmorillonite powder for oral administration, followed by small-volume low-pressure manual gastric lavage with 2.5%bicarbonate liquid. Then 30 g of activated charcoal, 30 g of montmorillonite powder, and polyethylene glycol electrolyte lavage solution were given one after another for gastrointestinal lavage once a day for five days. Both groups received large doses of corticosteroids, blood perfusion, and anti-oxidation treatment. The levels of serum potassium, serum amylase (AMY) alanine aminotransferase (ALT), total bilirubin (TBIL), blood urea nitrogen (BUN), creatinine (Cr), lactate (Lac), and PaO₂of patients were determined at 1, 3, 5, 7, and 10 days. Laxative time, mortality, and survival time of dead cases were evaluated in the two groups. The incidence rates of hypokalemia (110 U/L) were significantly lower in the sequential treatment group than in the conventional treatment group (P 80 U/L), TBIL (>34.2 µmol/L), BUN (>7.2 mmol/L), and Cr (>177 µmol/L) between the two groups (P>0.05). However, the highest levels of ALT, TBIL, BUN, Cr, and Lac were significantly lower in the sequential treatment group than in the conventional treatment group (P treatment group had significantly lower incidence of PaO₂(treatment group (P poisoning.

  6. Optical properties of multicomponent antimony-silver nanoclusters formed in silica by sequential ion implantation

    International Nuclear Information System (INIS)

    Zuhr, R.A.

    1995-11-01

    The linear and nonlinear optical properties of nanometer dimension metal colloids embedded in a dielectric depend explicitly on the electronic structure of the metal nanoclusters. The ability to control the electronic structure of the nanoclusters may make it possible to tailor the optical properties for enhanced performance. By sequential implantation of different metal ion species multi-component nanoclusters can be formed with significantly different optical properties than single element metal nanoclusters. The authors report the formation of multi-component Sb/Ag nanoclusters in silica by sequential implantation of Sb and Ag. Samples were implanted with relative ratios of Sb to Ag of 1:1 and 3:1. A second set of samples was made by single element implantations of Ag and Sb at the same energies and doses used to make the sequentially implanted samples. All samples were characterized using RBS and both linear and nonlinear optical measurements. The presence of both ions significantly modifies the optical properties of the composites compared to the single element nanocluster glass composites. In the sequentially implanted samples the optical density is lower, and the strong surface plasmon resonance absorption observed in the Ag implanted samples is not present. At the same time the nonlinear response of the these samples is larger than for the samples implanted with Sb alone, suggesting that the addition of Ag can increase the nonlinear response of the Sb particles formed. The results are consistent with the formation of multi-component Sb/Ag colloids

  7. Types I and III procollagen extension peptides in serum respond to fracture in humans

    DEFF Research Database (Denmark)

    Joerring, S; Jensen, L T; Andersen, G R

    1992-01-01

    Markers of types I and III collagen turnover were measured in serial blood samples in 16 patients with a Colles' fracture. The collagen markers were the carboxy-terminal extension peptide of type I procollagen (PICP) and the amino-terminal extension peptide of type III procollagen (PIIINP......). Significant increases were found of PIIINP within 1 week and of PICP within 2 weeks. This sequential appearance of PIIINP and PICP was found to be in agreement with the appearance of types III and I collagen during early fracture healing as demonstrated in previous animal experimental studies. PICP had...... levelled off after 9 months, whereas PIIINP remained elevated. Osteocalcin, a serum marker of osteoblast activity, increased within 1 week and levelled off after 9 months. Correlations between the change in osteocalcin and those in PICP and PIIINP, respectively, were weak. These new biochemical markers may...

  8. Sequential dependencies in magnitude scaling of loudness

    DEFF Research Database (Denmark)

    Joshi, Suyash Narendra; Jesteadt, Walt

    2013-01-01

    Ten normally hearing listeners used a programmable sone-potentiometer knob to adjust the level of a 1000-Hz sinusoid to match the loudness of numbers presented to them in a magnitude production task. Three different power-law exponents (0.15, 0.30, and 0.60) and a log-law with equal steps in d......B were used to program the sone-potentiometer. The knob settings systematically influenced the form of the loudness function. Time series analysis was used to assess the sequential dependencies in the data, which increased with increasing exponent and were greatest for the log-law. It would be possible......, therefore, to choose knob properties that minimized these dependencies. When the sequential dependencies were removed from the data, the slope of the loudness functions did not change, but the variability decreased. Sequential dependencies were only present when the level of the tone on the previous trial...

  9. Protein electrophoresis - serum

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003540.htm Protein electrophoresis - serum To use the sharing features on ... JavaScript. This lab test measures the types of protein in the fluid (serum) part of a blood ...

  10. The study in the relationship between serum calcium and serum parathyroid hormone (PTH) by employing the various kits of PTH assay

    International Nuclear Information System (INIS)

    Torizumi, Kazutami; Aibata, Hirofumi; Taniguchi, Yoshiyuki; Kiji, Shigeyuki; Ueyoshi, Akitaka; Shimizu, Eiji; Okamoto, Yukiharu; Tuda, Tadaaki; Ota, Kiichiro

    1987-01-01

    In order to evaluate the influences of serum PTH assay in the various concentrations of serum calcium, we divided into three groups which serum calcium had below 8.0 mg/dl, 8.2 mg/dl to 9.8 mg/dl and above 10.0 mg/dl at random samples and assayed PTH in serum sample, using various kits of PTH assay obtained from commercial sources. Our results suggested that the measurement of serum PTH influenced by the concentration of serum calcium and therefore, should be taken an attention of serum calcium in each sample. (author)

  11. Dihydroazulene photoswitch operating in sequential tunneling regime

    DEFF Research Database (Denmark)

    Broman, Søren Lindbæk; Lara-Avila, Samuel; Thisted, Christine Lindbjerg

    2012-01-01

    to electrodes so that the electron transport goes by sequential tunneling. To assure weak coupling, the DHA switching kernel is modified by incorporating p-MeSC6H4 end-groups. Molecules are prepared by Suzuki cross-couplings on suitable halogenated derivatives of DHA. The synthesis presents an expansion of our......, incorporating a p-MeSC6H4 anchoring group in one end, has been placed in a silver nanogap. Conductance measurements justify that transport through both DHA (high resistivity) and VHF (low resistivity) forms goes by sequential tunneling. The switching is fairly reversible and reenterable; after more than 20 ON...

  12. Asynchronous Operators of Sequential Logic Venjunction & Sequention

    CERN Document Server

    Vasyukevich, Vadim

    2011-01-01

    This book is dedicated to new mathematical instruments assigned for logical modeling of the memory of digital devices. The case in point is logic-dynamical operation named venjunction and venjunctive function as well as sequention and sequentional function. Venjunction and sequention operate within the framework of sequential logic. In a form of the corresponding equations, they organically fit analytical expressions of Boolean algebra. Thus, a sort of symbiosis is formed using elements of asynchronous sequential logic on the one hand and combinational logic on the other hand. So, asynchronous

  13. Comparison of Serum Vit D Level Between Psoriasis Patients and Normal Population

    Directory of Open Access Journals (Sweden)

    A. Darjani

    2016-11-01

    Full Text Available Introduction: Psoriasis is a common inflammatory skin disorder with humeral and cellular immune system involvement. On the other hands، Vitamin D has important immunomodulatory effects and its relations with many autoimmune diseases were shown. The relation between Serum Vit D Level and Psoriasis disease remained controversial issue that this study was done to show this relationship. Methods and Materials: In this comparative cross sectional study، 30 psoriatic patients who attended to Razi dermatology clinic in Rasht، by sequential sampling underwent study as case group. 30 healthy people from hospital at the same age، gender and skin-colored also were selected as control group. Inclusion criteria were patients and people without Ca or Vit D supplements usage or underground diseases in relation to hypovitaminosis D. Demographical data were gathered by interviewing and then blood samples from all participants were sent for analysis of serum Ca، P، Vit D and parathormone level. Data analysis was done by SPSS ver. 18 using T-test and Chi 2 test. Result: Mean and SD serum level of Vit D in case and control groups were 25.8± 12.6 ng/ mL and  23.7± 8.9 ng/ mL، respectively (ρ>0.05. Out of all، 24 participants (40% suffered from Vit D Deficiency and 20 people (33.3% from Vit D insufficiency ، only 26.7% study subjects had acceptable serum Vit D level. There were not any significant difference between Vit D deficiency rates and other measured biochemical indices in two groups (36.7% vs. 43.3%. Conclusion: This study showed high level of Vit D deficiency in both psoriatic and normal people that must be notice.

  14. Mobility of radionuclides based on sequential extraction of soils

    International Nuclear Information System (INIS)

    Salbu, B.; Oughton, D.H.; Lien, H.N.; Oestby, G.; Strand, P.

    1992-01-01

    Since 1989, core samples of soil and vegetation from semi-natural pastures have been collected at selected sites in Norway during the growing season. The activity concentrations in soil and vegetation as well as transfer coefficients vary significantly between regions, within regions and even within sampling plot areas. In order to differentiate between mobil and inert fractions of radioactive and stable isotopes of Cs and Sr in soils, samples were extracted sequentially using agents with increasing dissolution power. The reproducibility of the sequential extraction technique is good and the data obtained seems most informative. As the distribution pattern for radioactive and stable isotopes of Cs and Sr are similar, a high degree of isotopic exchange is indicated. Based on easily leachable fractions, mobility factors are calculated. In general the mobility of 90 Sr is higher than for 137 Cs. Mobility factors are not significantly influenced by seasonal variations, but a decrease in the mobile fraction in soil with time is indicated. Mobility factors should be considered useful for modelling purposes. (au)

  15. Serotonin syndrome following sibutramine poisoning in a child, with sequential quantification of sibutramine and its primary and secondary amine metabolites in plasma.

    Science.gov (United States)

    Bucaretchi, Fábio; de Capitani, Eduardo Mello; Mello, Sueli Moreira; Lanaro, Rafael; Barros, Roberta F; Fernandes, Luciane C R; da Costa, José Luiz; Hyslop, Stephen

    2009-07-01

    To report a case of serotonin syndrome (SS) after sibutramine overdose in a child. A 4-year-old girl was admitted 25 h after accidentally ingesting approximately 27 pills of sibutramine (15 mg, approximately 23 mg/kg). The child developed clinical features suggestive of SS, including diaphoresis, tachycardia, hypertension, agitation, insomnia, incoordination, hypertonia (lower limbs > upper limbs), and hallucinations. Serum creatine phosphokinase levels reached a peak on day 3 (2,577 U/L, reference value sibutramine and the active metabolites, M1 (mono-desmethyl sibutramine) and M2 (di-desmethyl sibutramine), by liquid chromatography/electrospray ionization tandem mass spectrometry in six sequential samples collected from 25 to 147 h post-ingestion revealed a nonlinear decrease in the log-scale plasma concentrations. Treatment was only supportive and involved prolonged sedation to control the agitation, sleeplessness, and hypertension; no cyproheptadine was used. The patient was discharged on day 6 and follow-up revealed no sequelae. To our knowledge, this is the first report of SS after sibutramine overdose in a child, with sequential monitoring of the plasma levels of the drug and its two active metabolites. The growing consumption of weight reducing pills may increase the risk of unintentional acute toxic exposures in children.

  16. Sequential cloud-point extraction for toxicological screening analysis of medicaments in human plasma by high pressure liquid chromatography with diode array detector.

    Science.gov (United States)

    Madej, Katarzyna; Persona, Karolina; Wandas, Monika; Gomółka, Ewa

    2013-10-18

    A complex extraction system with the use of cloud-point extraction technique (CPE) was developed for sequential isolation of basic and acidic/neutral medicaments from human plasma/serum, screened by HPLC/DAD method. Eight model drugs (paracetamol, promazine, chlorpromazine, amitriptyline, salicyclic acid, opipramol, alprazolam and carbamazepine) were chosen for the study of optimal CPE conditions. The CPE technique consists in partition of an aqueous sample with addition of a surfactant into two phases: micelle-rich phase with the isolated compounds and water phase containing a surfactant below the critical micellar concentration, mainly under influence of temperature change. The proposed extraction system consists of two chief steps: isolation of basic compounds (from pH 12) and then isolation of acidic/neutral compounds (from pH 6) using surfactant Triton X-114 as the extraction medium. Extraction recovery varied from 25.2 to 107.9% with intra-day and inter-day precision (RSD %) ranged 0.88-1087 and 5.32-17.96, respectively. The limits of detection for the studied medicaments at λ 254nm corresponded to therapeutic or low toxic plasma concentration levels. Usefulness of the proposed CPE-HPLC/DAD method for toxicological drug screening was tested via its application to analysis of two serum samples taken from patients suspected of drug overdosing. Published by Elsevier B.V.

  17. Eyewitness confidence in simultaneous and sequential lineups: a criterion shift account for sequential mistaken identification overconfidence.

    Science.gov (United States)

    Dobolyi, David G; Dodson, Chad S

    2013-12-01

    Confidence judgments for eyewitness identifications play an integral role in determining guilt during legal proceedings. Past research has shown that confidence in positive identifications is strongly associated with accuracy. Using a standard lineup recognition paradigm, we investigated accuracy using signal detection and ROC analyses, along with the tendency to choose a face with both simultaneous and sequential lineups. We replicated past findings of reduced rates of choosing with sequential as compared to simultaneous lineups, but notably found an accuracy advantage in favor of simultaneous lineups. Moreover, our analysis of the confidence-accuracy relationship revealed two key findings. First, we observed a sequential mistaken identification overconfidence effect: despite an overall reduction in false alarms, confidence for false alarms that did occur was higher with sequential lineups than with simultaneous lineups, with no differences in confidence for correct identifications. This sequential mistaken identification overconfidence effect is an expected byproduct of the use of a more conservative identification criterion with sequential than with simultaneous lineups. Second, we found a steady drop in confidence for mistaken identifications (i.e., foil identifications and false alarms) from the first to the last face in sequential lineups, whereas confidence in and accuracy of correct identifications remained relatively stable. Overall, we observed that sequential lineups are both less accurate and produce higher confidence false identifications than do simultaneous lineups. Given the increasing prominence of sequential lineups in our legal system, our data argue for increased scrutiny and possibly a wholesale reevaluation of this lineup format. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  18. Aspects of the Hematology and Serum Biochemistry of Sahel and ...

    African Journals Online (AJOL)

    This study was conducted to investigate effects of year, age, season and breeds on aspects of the hematology and serum biochemical indices of Sahel and Sokoto red bucks in Mubi, Adamawa state, Nigeria. Blood and serum samples were used to determine PCV, Hb, RBC and WBC, and while serum protein (BSP) and ...

  19. Iron and ADHD: Time to Move beyond Serum Ferritin Levels

    Science.gov (United States)

    Donfrancesco, Renato; Parisi, Pasquale; Vanacore, Nicola; Martines, Francesca; Sargentini, Vittorio; Cortese, Samuele

    2013-01-01

    Objective: (a) To compare serum ferritin levels in a sample of stimulant-naive children with ADHD and matched controls and (b) to assess the association of serum ferritin to ADHD symptoms severity, ADHD subtypes, and IQ. Method: The ADHD and the control groups included 101 and 93 children, respectively. Serum ferritin levels were determined with…

  20. Interpretability degrees of finitely axiomatized sequential theories

    NARCIS (Netherlands)

    Visser, Albert

    In this paper we show that the degrees of interpretability of finitely axiomatized extensions-in-the-same-language of a finitely axiomatized sequential theory-like Elementary Arithmetic EA, IΣ1, or the Gödel-Bernays theory of sets and classes GB-have suprema. This partially answers a question posed

  1. Interpretability Degrees of Finitely Axiomatized Sequential Theories

    NARCIS (Netherlands)

    Visser, Albert

    2012-01-01

    In this paper we show that the degrees of interpretability of finitely axiomatized extensions-in-the-same-language of a finitely axiomatized sequential theory —like Elementary Arithmetic EA, IΣ1, or the Gödel-Bernays theory of sets and classes GB— have suprema. This partially answers a question

  2. S.M.P. SEQUENTIAL MATHEMATICS PROGRAM.

    Science.gov (United States)

    CICIARELLI, V; LEONARD, JOSEPH

    A SEQUENTIAL MATHEMATICS PROGRAM BEGINNING WITH THE BASIC FUNDAMENTALS ON THE FOURTH GRADE LEVEL IS PRESENTED. INCLUDED ARE AN UNDERSTANDING OF OUR NUMBER SYSTEM, AND THE BASIC OPERATIONS OF WORKING WITH WHOLE NUMBERS--ADDITION, SUBTRACTION, MULTIPLICATION, AND DIVISION. COMMON FRACTIONS ARE TAUGHT IN THE FIFTH, SIXTH, AND SEVENTH GRADES. A…

  3. Sequential and Simultaneous Logit: A Nested Model.

    NARCIS (Netherlands)

    van Ophem, J.C.M.; Schram, A.J.H.C.

    1997-01-01

    A nested model is presented which has both the sequential and the multinomial logit model as special cases. This model provides a simple test to investigate the validity of these specifications. Some theoretical properties of the model are discussed. In the analysis a distribution function is

  4. Sensitivity Analysis in Sequential Decision Models.

    Science.gov (United States)

    Chen, Qiushi; Ayer, Turgay; Chhatwal, Jagpreet

    2017-02-01

    Sequential decision problems are frequently encountered in medical decision making, which are commonly solved using Markov decision processes (MDPs). Modeling guidelines recommend conducting sensitivity analyses in decision-analytic models to assess the robustness of the model results against the uncertainty in model parameters. However, standard methods of conducting sensitivity analyses cannot be directly applied to sequential decision problems because this would require evaluating all possible decision sequences, typically in the order of trillions, which is not practically feasible. As a result, most MDP-based modeling studies do not examine confidence in their recommended policies. In this study, we provide an approach to estimate uncertainty and confidence in the results of sequential decision models. First, we provide a probabilistic univariate method to identify the most sensitive parameters in MDPs. Second, we present a probabilistic multivariate approach to estimate the overall confidence in the recommended optimal policy considering joint uncertainty in the model parameters. We provide a graphical representation, which we call a policy acceptability curve, to summarize the confidence in the optimal policy by incorporating stakeholders' willingness to accept the base case policy. For a cost-effectiveness analysis, we provide an approach to construct a cost-effectiveness acceptability frontier, which shows the most cost-effective policy as well as the confidence in that for a given willingness to pay threshold. We demonstrate our approach using a simple MDP case study. We developed a method to conduct sensitivity analysis in sequential decision models, which could increase the credibility of these models among stakeholders.

  5. Sequential models for coarsening and missingness

    NARCIS (Netherlands)

    Gill, R.D.; Robins, J.M.

    1997-01-01

    In a companion paper we described what intuitively would seem to be the most general possible way to generate Coarsening at Random mechanisms a sequential procedure called randomized monotone coarsening Counterexamples showed that CAR mechanisms exist which cannot be represented in this way Here we

  6. Sequential motor skill: cognition, perception and action

    NARCIS (Netherlands)

    Ruitenberg, M.F.L.

    2013-01-01

    Discrete movement sequences are assumed to be the building blocks of more complex sequential actions that are present in our everyday behavior. The studies presented in this dissertation address the (neuro)cognitive underpinnings of such movement sequences, in particular in relationship to the role

  7. Sequential decoders for large MIMO systems

    KAUST Repository

    Ali, Konpal S.; Abediseid, Walid; Alouini, Mohamed-Slim

    2014-01-01

    the Sequential Decoder using the Fano Algorithm for large MIMO systems. A parameter called the bias is varied to attain different performance-complexity trade-offs. Low values of the bias result in excellent performance but at the expense of high complexity

  8. A framework for sequential multiblock component methods

    NARCIS (Netherlands)

    Smilde, A.K.; Westerhuis, J.A.; Jong, S.de

    2003-01-01

    Multiblock or multiset methods are starting to be used in chemistry and biology to study complex data sets. In chemometrics, sequential multiblock methods are popular; that is, methods that calculate one component at a time and use deflation for finding the next component. In this paper a framework

  9. Classical and sequential limit analysis revisited

    Science.gov (United States)

    Leblond, Jean-Baptiste; Kondo, Djimédo; Morin, Léo; Remmal, Almahdi

    2018-04-01

    Classical limit analysis applies to ideal plastic materials, and within a linearized geometrical framework implying small displacements and strains. Sequential limit analysis was proposed as a heuristic extension to materials exhibiting strain hardening, and within a fully general geometrical framework involving large displacements and strains. The purpose of this paper is to study and clearly state the precise conditions permitting such an extension. This is done by comparing the evolution equations of the full elastic-plastic problem, the equations of classical limit analysis, and those of sequential limit analysis. The main conclusion is that, whereas classical limit analysis applies to materials exhibiting elasticity - in the absence of hardening and within a linearized geometrical framework -, sequential limit analysis, to be applicable, strictly prohibits the presence of elasticity - although it tolerates strain hardening and large displacements and strains. For a given mechanical situation, the relevance of sequential limit analysis therefore essentially depends upon the importance of the elastic-plastic coupling in the specific case considered.

  10. Sequential spatial processes for image analysis

    NARCIS (Netherlands)

    M.N.M. van Lieshout (Marie-Colette); V. Capasso

    2009-01-01

    htmlabstractWe give a brief introduction to sequential spatial processes. We discuss their definition, formulate a Markov property, and indicate why such processes are natural tools in tackling high level vision problems. We focus on the problem of tracking a variable number of moving objects

  11. Sequential spatial processes for image analysis

    NARCIS (Netherlands)

    Lieshout, van M.N.M.; Capasso, V.

    2009-01-01

    We give a brief introduction to sequential spatial processes. We discuss their definition, formulate a Markov property, and indicate why such processes are natural tools in tackling high level vision problems. We focus on the problem of tracking a variable number of moving objects through a video

  12. STABILIZED SEQUENTIAL QUADRATIC PROGRAMMING: A SURVEY

    Directory of Open Access Journals (Sweden)

    Damián Fernández

    2014-12-01

    Full Text Available We review the motivation for, the current state-of-the-art in convergence results, and some open questions concerning the stabilized version of the sequential quadratic programming algorithm for constrained optimization. We also discuss the tools required for its local convergence analysis, globalization challenges, and extentions of the method to the more general variational problems.

  13. Truly costly sequential search and oligopolistic pricing

    NARCIS (Netherlands)

    Janssen, Maarten C W; Moraga-González, José Luis; Wildenbeest, Matthijs R.

    We modify the paper of Stahl (1989) [Stahl, D.O., 1989. Oligopolistic pricing with sequential consumer search. American Economic Review 79, 700-12] by relaxing the assumption that consumers obtain the first price quotation for free. When all price quotations are costly to obtain, the unique

  14. Zips : mining compressing sequential patterns in streams

    NARCIS (Netherlands)

    Hoang, T.L.; Calders, T.G.K.; Yang, J.; Mörchen, F.; Fradkin, D.; Chau, D.H.; Vreeken, J.; Leeuwen, van M.; Faloutsos, C.

    2013-01-01

    We propose a streaming algorithm, based on the minimal description length (MDL) principle, for extracting non-redundant sequential patterns. For static databases, the MDL-based approach that selects patterns based on their capacity to compress data rather than their frequency, was shown to be

  15. How to Read the Tractatus Sequentially

    Directory of Open Access Journals (Sweden)

    Tim Kraft

    2016-11-01

    Full Text Available One of the unconventional features of Wittgenstein’s Tractatus Logico-Philosophicus is its use of an elaborated and detailed numbering system. Recently, Bazzocchi, Hacker und Kuusela have argued that the numbering system means that the Tractatus must be read and interpreted not as a sequentially ordered book, but as a text with a two-dimensional, tree-like structure. Apart from being able to explain how the Tractatus was composed, the tree reading allegedly solves exegetical issues both on the local (e. g. how 4.02 fits into the series of remarks surrounding it and the global level (e. g. relation between ontology and picture theory, solipsism and the eye analogy, resolute and irresolute readings. This paper defends the sequential reading against the tree reading. After presenting the challenges generated by the numbering system and the two accounts as attempts to solve them, it is argued that Wittgenstein’s own explanation of the numbering system, anaphoric references within the Tractatus and the exegetical issues mentioned above do not favour the tree reading, but a version of the sequential reading. This reading maintains that the remarks of the Tractatus form a sequential chain: The role of the numbers is to indicate how remarks on different levels are interconnected to form a concise, surveyable and unified whole.

  16. Adult Word Recognition and Visual Sequential Memory

    Science.gov (United States)

    Holmes, V. M.

    2012-01-01

    Two experiments were conducted investigating the role of visual sequential memory skill in the word recognition efficiency of undergraduate university students. Word recognition was assessed in a lexical decision task using regularly and strangely spelt words, and nonwords that were either standard orthographically legal strings or items made from…

  17. Terminating Sequential Delphi Survey Data Collection

    Science.gov (United States)

    Kalaian, Sema A.; Kasim, Rafa M.

    2012-01-01

    The Delphi survey technique is an iterative mail or electronic (e-mail or web-based) survey method used to obtain agreement or consensus among a group of experts in a specific field on a particular issue through a well-designed and systematic multiple sequential rounds of survey administrations. Each of the multiple rounds of the Delphi survey…

  18. Sequential Monte Carlo Instant Radiosity.

    Science.gov (United States)

    Hedman, Peter; Karras, Tero; Lehtinen, Jaakko

    2017-05-01

    Instant Radiosity and its derivatives are interactive methods for efficiently estimating global (indirect) illumination. They represent the last indirect bounce of illumination before the camera as the composite radiance field emitted by a set of virtual point light sources (VPLs). In complex scenes, current algorithms suffer from a difficult combination of two issues: it remains a challenge to distribute VPLs in a manner that simultaneously gives a high-quality indirect illumination solution for each frame, and to do so in a temporally coherent manner. We address both issues by building, and maintaining over time, an adaptive and temporally coherent distribution of VPLs in locations where they bring indirect light to the image. We introduce a novel heuristic sampling method that strives to only move as few of the VPLs between frames as possible. The result is, to the best of our knowledge, the first interactive global illumination algorithm that works in complex, highly-occluded scenes, suffers little from temporal flickering, supports moving cameras and light sources, and is output-sensitive in the sense that it places VPLs in locations that matter most to the final result.

  19. A Bayesian sequential design with adaptive randomization for 2-sided hypothesis test.

    Science.gov (United States)

    Yu, Qingzhao; Zhu, Lin; Zhu, Han

    2017-11-01

    Bayesian sequential and adaptive randomization designs are gaining popularity in clinical trials thanks to their potentials to reduce the number of required participants and save resources. We propose a Bayesian sequential design with adaptive randomization rates so as to more efficiently attribute newly recruited patients to different treatment arms. In this paper, we consider 2-arm clinical trials. Patients are allocated to the 2 arms with a randomization rate to achieve minimum variance for the test statistic. Algorithms are presented to calculate the optimal randomization rate, critical values, and power for the proposed design. Sensitivity analysis is implemented to check the influence on design by changing the prior distributions. Simulation studies are applied to compare the proposed method and traditional methods in terms of power and actual sample sizes. Simulations show that, when total sample size is fixed, the proposed design can obtain greater power and/or cost smaller actual sample size than the traditional Bayesian sequential design. Finally, we apply the proposed method to a real data set and compare the results with the Bayesian sequential design without adaptive randomization in terms of sample sizes. The proposed method can further reduce required sample size. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Protein Turnover Measurements in Human Serum by Serial Immunoaffinity LC-MS/MS.

    Science.gov (United States)

    Farrokhi, Vahid; Chen, Xiaoying; Neubert, Hendrik

    2018-02-01

    The half-life of target proteins is frequently an important parameter in mechanistic pharmacokinetic and pharmacodynamic (PK/PD) modeling of biotherapeutics. Clinical studies for accurate measurement of physiologically relevant protein turnover can reduce the uncertainty in PK/PD model-based predictions, for example, of the therapeutic dose and dosing regimen in first-in-human clinical trials. We used a targeted mass spectrometry work flow based on serial immunoaffinity enrichment ofmultiple human serum proteins from a [5,5,5- 2 H 3 ]-L-leucine tracer pulse-chase study in healthy volunteers. To confirm the reproducibility of turnover measurements from serial immunoaffinity enrichment, multiple aliquots from the same sample set were subjected to protein turnover analysis in varying order. Tracer incorporation was measured by multiple-reaction-monitoring mass spectrometry and target turnover was calculated using a four-compartment pharmacokinetic model. Five proteins of clinical or therapeutic relevance including soluble tumor necrosis factor receptor superfamily member 12A, tissue factor pathway inhibitor, soluble interleukin 1 receptor like 1, soluble mucosal addressin cell adhesion molecule 1, and muscle-specific creatine kinase were sequentially subjected to turnover analysis from the same human serum sample. Calculated half-lives ranged from 5-15 h; however, no tracer incorporation was observed for mucosal addressin cell adhesion molecule 1. The utility of clinical pulse-chase studies to investigate protein turnover can be extended by serial immunoaffinity enrichment of target proteins. Turnover analysis from serum and subsequently from remaining supernatants provided analytical sensitivity and reproducibility for multiple human target proteins in the same sample set, irrespective of the order of analysis. © 2017 American Association for Clinical Chemistry.

  1. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239

    OpenAIRE

    Powell, Rebecca L.R.; Ouellette, Ian; Lindsay, Ross W.; Parks, Christopher L.; King, C. Richter; McDermott, Adrian B.; Morrow, Gavin

    2013-01-01

    Abstract Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, w...

  2. Impact of Diagrams on Recalling Sequential Elements in Expository Texts.

    Science.gov (United States)

    Guri-Rozenblit, Sarah

    1988-01-01

    Examines the instructional effectiveness of abstract diagrams on recall of sequential relations in social science textbooks. Concludes that diagrams assist significantly the recall of sequential relations in a text and decrease significantly the rate of order mistakes. (RS)

  3. Group sequential designs for stepped-wedge cluster randomised trials.

    Science.gov (United States)

    Grayling, Michael J; Wason, James Ms; Mander, Adrian P

    2017-10-01

    The stepped-wedge cluster randomised trial design has received substantial attention in recent years. Although various extensions to the original design have been proposed, no guidance is available on the design of stepped-wedge cluster randomised trials with interim analyses. In an individually randomised trial setting, group sequential methods can provide notable efficiency gains and ethical benefits. We address this by discussing how established group sequential methodology can be adapted for stepped-wedge designs. Utilising the error spending approach to group sequential trial design, we detail the assumptions required for the determination of stepped-wedge cluster randomised trials with interim analyses. We consider early stopping for efficacy, futility, or efficacy and futility. We describe first how this can be done for any specified linear mixed model for data analysis. We then focus on one particular commonly utilised model and, using a recently completed stepped-wedge cluster randomised trial, compare the performance of several designs with interim analyses to the classical stepped-wedge design. Finally, the performance of a quantile substitution procedure for dealing with the case of unknown variance is explored. We demonstrate that the incorporation of early stopping in stepped-wedge cluster randomised trial designs could reduce the expected sample size under the null and alternative hypotheses by up to 31% and 22%, respectively, with no cost to the trial's type-I and type-II error rates. The use of restricted error maximum likelihood estimation was found to be more important than quantile substitution for controlling the type-I error rate. The addition of interim analyses into stepped-wedge cluster randomised trials could help guard against time-consuming trials conducted on poor performing treatments and also help expedite the implementation of efficacious treatments. In future, trialists should consider incorporating early stopping of some kind into

  4. Screening and staging for non-small cell lung cancer by serum laser Raman spectroscopy.

    Science.gov (United States)

    Wang, Hong; Zhang, Shaohong; Wan, Limei; Sun, Hong; Tan, Jie; Su, Qiucheng

    2018-08-05

    Lung cancer is the leading cause of cancer-related death worldwide. Current clinical screening methods to detect lung cancer are expensive and associated with many complications. Raman spectroscopy is a spectroscopic technique that offers a convenient method to gain molecular information about biological samples. In this study, we measured the serum Raman spectral intensity of healthy volunteers and patients with different stages of non-small cell lung cancer. The purpose of this study was to evaluate the application of serum laser Raman spectroscopy as a low cost alternative method in the screening and staging of non-small cell lung cancer (NSCLC). The Raman spectra of the sera of peripheral venous blood were measured with a LabRAM HR 800 confocal Micro Raman spectrometer for individuals from five groups including 14 healthy volunteers (control group), 23 patients with stage I NSCLC (stage I group), 24 patients with stage II NSCLC (stage II group), 19 patients with stage III NSCLC (stage III group), 11 patients with stage IV NSCLC (stage IV group). Each serum sample was measured 3 times at different spots and the average spectra represented the signal of Raman spectra in each case. The Raman spectrum signal data of the five groups were statistically analyzed by analysis of variance (ANOVA), principal component analysis (PCA), linear discriminant analysis (LDA), and cross-validation. Raman spectral intensity was sequentially reduced in serum samples from control group, stage I group, stage II group and stage III/IV group. The strongest peak intensity was observed in the control group, and the weakest one was found in the stage III/IV group at bands of 848 cm -1 , 999 cm -1 , 1152 cm -1 , 1446 cm -1 and 1658 cm -1 (P Raman spectroscopy can effectively identify patients with stage I, stage II or stage III/IV Non-Small Cell Lung cancer using patient serum samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. A one-sided sequential test

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Lux, I. [Hungarian Academy of Sciences, Budapest (Hungary). Atomic Energy Research Inst.

    1996-04-16

    The applicability of the classical sequential probability ratio testing (SPRT) for early failure detection problems is limited by the fact that there is an extra time delay between the occurrence of the failure and its first recognition. Chien and Adams developed a method to minimize this time for the case when the problem can be formulated as testing the mean value of a Gaussian signal. In our paper we propose a procedure that can be applied for both mean and variance testing and that minimizes the time delay. The method is based on a special parametrization of the classical SPRT. The one-sided sequential tests (OSST) can reproduce the results of the Chien-Adams test when applied for mean values. (author).

  6. Documentscape: Intertextuality, Sequentiality & Autonomy at Work

    DEFF Research Database (Denmark)

    Christensen, Lars Rune; Bjørn, Pernille

    2014-01-01

    On the basis of an ethnographic field study, this article introduces the concept of documentscape to the analysis of document-centric work practices. The concept of documentscape refers to the entire ensemble of documents in their mutual intertextual interlocking. Providing empirical data from...... a global software development case, we show how hierarchical structures and sequentiality across the interlocked documents are critical to how actors make sense of the work of others and what to do next in a geographically distributed setting. Furthermore, we found that while each document is created...... as part of a quasi-sequential order, this characteristic does not make the document, as a single entity, into a stable object. Instead, we found that the documents were malleable and dynamic while suspended in intertextual structures. Our concept of documentscape points to how the hierarchical structure...

  7. Optimal Sequential Rules for Computer-Based Instruction.

    Science.gov (United States)

    Vos, Hans J.

    1998-01-01

    Formulates sequential rules for adapting the appropriate amount of instruction to learning needs in the context of computer-based instruction. Topics include Bayesian decision theory, threshold and linear-utility structure, psychometric model, optimal sequential number of test questions, and an empirical example of sequential instructional…

  8. On Locally Most Powerful Sequential Rank Tests

    Czech Academy of Sciences Publication Activity Database

    Kalina, Jan

    2017-01-01

    Roč. 36, č. 1 (2017), s. 111-125 ISSN 0747-4946 R&D Projects: GA ČR GA17-07384S Grant - others:Nadační fond na podporu vědy(CZ) Neuron Institutional support: RVO:67985807 Keywords : nonparametric test s * sequential ranks * stopping variable Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.339, year: 2016

  9. Sequential pattern recognition by maximum conditional informativity

    Czech Academy of Sciences Publication Activity Database

    Grim, Jiří

    2014-01-01

    Roč. 45, č. 1 (2014), s. 39-45 ISSN 0167-8655 R&D Projects: GA ČR(CZ) GA14-02652S; GA ČR(CZ) GA14-10911S Keywords : Multivariate statistics * Statistical pattern recognition * Sequential decision making * Product mixtures * EM algorithm * Shannon information Subject RIV: IN - Informatics, Computer Sci ence Impact factor: 1.551, year: 2014 http://library.utia.cas.cz/separaty/2014/RO/grim-0428565.pdf

  10. Sequential test procedures for inventory differences

    International Nuclear Information System (INIS)

    Goldman, A.S.; Kern, E.A.; Emeigh, C.W.

    1985-01-01

    By means of a simulation study, we investigated the appropriateness of Page's and power-one sequential tests on sequences of inventory differences obtained from an example materials control unit, a sub-area of a hypothetical UF 6 -to-U 3 O 8 conversion process. The study examined detection probability and run length curves obtained from different loss scenarios. 12 refs., 10 figs., 2 tabs

  11. Sequential neural models with stochastic layers

    DEFF Research Database (Denmark)

    Fraccaro, Marco; Sønderby, Søren Kaae; Paquet, Ulrich

    2016-01-01

    How can we efficiently propagate uncertainty in a latent state representation with recurrent neural networks? This paper introduces stochastic recurrent neural networks which glue a deterministic recurrent neural network and a state space model together to form a stochastic and sequential neural...... generative model. The clear separation of deterministic and stochastic layers allows a structured variational inference network to track the factorization of the model's posterior distribution. By retaining both the nonlinear recursive structure of a recurrent neural network and averaging over...

  12. Sequential and Simultaneous Processing in Children with Learning Disabilities: An Attempted Replication.

    Science.gov (United States)

    Bain, Sherry K.

    1993-01-01

    Analysis of Kaufman Assessment Battery for Children (K-ABC) Sequential and Simultaneous Processing scores of 94 children (ages 6-12) with learning disabilities produced factor patterns generally supportive of the traditional K-ABC Mental Processing structure with the exception of Spatial Memory. The sample exhibited relative processing strengths…

  13. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    Science.gov (United States)

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  14. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    Science.gov (United States)

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  15. Soluble serum Klotho levels in healthy subjects

    DEFF Research Database (Denmark)

    Pedersen, Lise Mariager; Pedersen, Susanne Møller; Brasen, Claus Lohman

    2013-01-01

    Klotho concentrations were determined in 120 healthy adults aged 19-66years. Blood samples were collected, and stored sera were assayed for Klotho according to age and gender. In addition several other clinical and laboratory characteristics were determined in the cohort and compared to the levels...... genders. Concentrations of serum Klotho were independently associated with estimated glomerular filtration rate (eGFR) and body weight using TRF whereas serum Klotho concentrations were associated with age using the ELISA. CONCLUSION: Comparison of two different immunoassays for serum Klotho indicate...

  16. Pharmacokinetics of sequential intravenous and enteral fluconazole in critically ill surgical patients with invasive mycoses and compromised gastro-intestinal function

    NARCIS (Netherlands)

    Buijk, S L; Gyssens, I C; Mouton, J W; Verbrugh, H A; Touw, D J; Bruining, H A

    OBJECTIVES: (1) To determine the pharmacokinetics of sequential intravenous and enteral fluconazole in the serum of surgical intensive care unit (ICU) patients with deep mycoses. (2) To determine the concentrations of fluconazole reached at the site of infection. (3) To determine if enteral

  17. Computer-assisted sequential quantitative analysis of gallium scans in pulmonary sarcoidosis

    International Nuclear Information System (INIS)

    Rohatgi, P.K.; Bates, H.R.; Noss, R.W.

    1985-01-01

    Fifty-one sequential gallium citrate scans were performed in 22 patients with biopsy-proven sarcoidosis. A computer-assisted quantitative analysis of these scans was performed to obtain a gallium score. The changes in gallium score were correlated with changes in serum angiotensin converting enzyme (SACE) activity and objective changes in clinical status. There was a good concordance between changes in gallium score, SACE activity and clinical assessment in patients with sarcoidosis, and changes in gallium index were slightly superior to SACE index in assessing activity of sarcoidosis. (author)

  18. A MEMS lamination technology based on sequential multilayer electrodeposition

    International Nuclear Information System (INIS)

    Kim, Minsoo; Kim, Jooncheol; Herrault, Florian; Schafer, Richard; Allen, Mark G

    2013-01-01

    A MEMS lamination technology based on sequential multilayer electrodeposition is presented. The process comprises three main steps: (1) automated sequential electrodeposition of permalloy (Ni 80 Fe 20 ) structural and copper sacrificial layers to form multilayer structures of significant total thickness; (2) fabrication of polymeric anchor structures through the thickness of the multilayer structures and (3) selective removal of copper. The resulting structure is a set of air-insulated permalloy laminations, the separation of which is sustained by insulating polymeric anchor structures. Individual laminations have precisely controllable thicknesses ranging from 500 nm to 5 µm, and each lamination layer is electrically isolated from adjacent layers by narrow air gaps of similar scale. In addition to air, interlamination insulators based on polymers are investigated. Interlamination air gaps with very high aspect ratio (>1:100) can be filled with polyvinylalcohol and polydimethylsiloxane. The laminated structures are characterized using scanning electron microscopy and atomic force microscopy to directly examine properties such as the roughness and the thickness uniformity of the layers. In addition, the quality of the electrical insulation between the laminations is evaluated by quantifying the eddy current within the sample as a function of frequency. Fabricated laminations are comprised of uniform, smooth (surface roughness <100 nm) layers with effective electrical insulation for all layer thicknesses and insulator approaches studied. Such highly laminated structures have potential uses ranging from energy conversion to applications where composite materials with highly anisotropic mechanical or thermal properties are required. (paper)

  19. [Sequential monitoring of renal transplant with aspiration cytology].

    Science.gov (United States)

    Manfro, R C; Gonçalves, L F; de Moura, L A

    1998-01-01

    To evaluate the utility of kidney aspiration cytology in the sequential monitorization of acute rejection in renal transplant patients. Thirty patients were submitted to 376 aspirations. The clinical diagnoses were independently established. The representativity of the samples reached 82.7%. The total corrected increment index and the number of immunoactivated cells were higher during acute rejection as compared to normal allograft function, acute tubular necrosis, and cyclosporine nephrotoxicity. The parameters to the diagnosis of acute rejection were sensitivity: 71.8%, specificity: 87.3%, positive predictive value: 50.9%, negative predictive value: 94.9% and accuracy 84.9%. The false positive results were mainly related to cytomegalovirus infection or to the administration of OKT3. In 10 out of 11 false negative results incipient immunoactivation was present alerting to the possibility of acute rejection. Kidney aspiration cytology is a useful tool for the sequential monitorization of acute rejection in renal transplant patients. The best results are reached when the results of aspiration cytology are analyzed with the clinical data.

  20. Group-Sequential Strategies in Clinical Trials with Multiple Co-Primary Outcomes

    Science.gov (United States)

    Hamasaki, Toshimitsu; Asakura, Koko; Evans, Scott R; Sugimoto, Tomoyuki; Sozu, Takashi

    2015-01-01

    We discuss the decision-making frameworks for clinical trials with multiple co-primary endpoints in a group-sequential setting. The decision-making frameworks can account for flexibilities such as a varying number of analyses, equally or unequally spaced increments of information and fixed or adaptive Type I error allocation among endpoints. The frameworks can provide efficiency, i.e., potentially fewer trial participants, than the fixed sample size designs. We investigate the operating characteristics of the decision-making frameworks and provide guidance on constructing efficient group-sequential strategies in clinical trials with multiple co-primary endpoints. PMID:25844122

  1. Bootstrap Sequential Determination of the Co-integration Rank in VAR Models

    DEFF Research Database (Denmark)

    Guiseppe, Cavaliere; Rahbæk, Anders; Taylor, A.M. Robert

    with empirical rejection frequencies often very much in excess of the nominal level. As a consequence, bootstrap versions of these tests have been developed. To be useful, however, sequential procedures for determining the co-integrating rank based on these bootstrap tests need to be consistent, in the sense...... in the literature by proposing a bootstrap sequential algorithm which we demonstrate delivers consistent cointegration rank estimation for general I(1) processes. Finite sample Monte Carlo simulations show the proposed procedure performs well in practice....

  2. Zinc in human serum

    International Nuclear Information System (INIS)

    Kiilerich, S.

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 per cent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of proteinbinding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and α 2 -macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a α 2 -macroglobulin in normal persons is appoximately 7 per cent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 per cent, in patients with insulin dependent diabetes mellitus approximately 5 per cent, and in patients with chronic renal failure approximately 2 per cent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin. (author)

  3. Consistency of self-reported alcohol consumption on randomized and sequential alcohol purchase tasks

    Directory of Open Access Journals (Sweden)

    Michael eAmlung

    2012-07-01

    Full Text Available Behavioral economic demand for addictive substances is commonly assessed via purchase tasks that measure estimated drug consumption at a range of prices. Purchase tasks typically use escalating prices in sequential order, which may influence performance by providing explicit price reference points. This study investigated the consistency of value preferences on two alcohol purchase tasks (APTs that used either a randomized or sequential price order (price range: free to $30 per drink in a sample of ninety-one young adult monthly drinkers. Randomization of prices significantly reduced relative response consistency (p < .01, although absolute consistency was high for both versions (>95%. Self-reported alcohol consumption across prices and indices of demand were highly similar across versions, although a few notable exceptions were found. These results suggest generally high consistency and overlapping performance between randomized and sequential price assessment. Implications for the behavioral economics literature and priorities for future research are discussed.

  4. Sequential Extraction Versus Comprehensive Characterization of Heavy Metal Species in Brownfield Soils

    Energy Technology Data Exchange (ETDEWEB)

    Dahlin, Cheryl L.; Williamson, Connie A.; Collins, W. Keith; Dahlin, David C.

    2002-06-01

    The applicability of sequential extraction as a means to determine species of heavy-metals was examined by a study on soil samples from two Superfund sites: the National Lead Company site in Pedricktown, NJ, and the Roebling Steel, Inc., site in Florence, NJ. Data from a standard sequential extraction procedure were compared to those from a comprehensive study that combined optical- and scanning-electron microscopy, X-ray diffraction, and chemical analyses. The study shows that larger particles of contaminants, encapsulated contaminants, and/or man-made materials such as slags, coke, metals, and plastics are subject to incasement, non-selectivity, and redistribution in the sequential extraction process. The results indicate that standard sequential extraction procedures that were developed for characterizing species of contaminants in river sediments may be unsuitable for stand-alone determinative evaluations of contaminant species in industrial-site materials. However, if employed as part of a comprehensive, site-specific characterization study, sequential extraction could be a very useful tool.

  5. Reference ranges for serum and salivary testosterone in young men of Mediterranean region.

    Science.gov (United States)

    González-Sánchez, Víctor; Moreno-Pérez, Oscar; García de Guadiana, Luis; Sánchez-Pellicer, Pedro; Alfayate, Rocío; Mauri, Montserrat; Sánchez-Payá, José; Picó, Antonio

    2015-01-01

    The interassay variability found in the measurement of testosterone (T) levels warrants the need for laboratories to validate their methods to establish trustworthy cut-off points for diagnosis of male hypogonadism. The aims of this study were to validate measurement of total T (TT) at our laboratory in order to obtain reference ranges for TT, calculated free T (CFT), calculated bioavailable T (CBT), and salivary T (ST) in healthy young men from the Mediterranean region, and to evaluate the potential clinical value of ST by establishing its correlation with serum T. An observational, cross-sectional study with sequential sampling. men aged 18-30 years with body mass index (BMI)9.7 nmol/L, CFT>0.22 nmol/L, and/or CBT>4.9 nmol/L make the presence of biochemical hypogonadism unlikely. According to the correlation between serum and ST, the clinical value of ST remains to be established. Copyright © 2014 SEEN. Published by Elsevier Espana. All rights reserved.

  6. Influence of sequential 125I particle chain implantation and transcatheter arterial chemoembolization on tumor cell killing effect in patients with liver cancer

    Directory of Open Access Journals (Sweden)

    Wei Dai

    2017-07-01

    Full Text Available Objective: To study the influence of sequential 125I particle chain implantation and transcatheter arterial chemoembolization (TACE on tumor cell killing effect in patients with liver cancer. Methods: A total of 82 cases of patients with advanced liver cancer who were treated in our hospital between September 2014 and December 2016 were collected, reviewed and then divided into the control group (n=45 who received TACE alone and the observation group (n=37 who received sequential 125I particle chain implantation and TACE. Serum levels of tumor markers, angiogenesis indexes and apoptosis molecules before and after treatments were compared between two groups of patients. Results: Before treatment, differences in serum levels of tumor markers, angiogenesis indexes and apoptosis molecules were not statistically significant between two groups of patients. After treatment, serum tumor markers AFP, CA199, CA153 and Ferritin levels in observation group were lower than those in control group; serum angiogenesis indexes VEGF, PEDF, ES and bFGF contents were lower than those in control group; serum apoptosis molecules p53 and Fas contents were higher than those in control group. Conclusion: Sequential 125I particle chain implantation and TACE treatment of advanced liver cancer can effectively reduce tumor malignancy and promote tumor apoptosis.

  7. The use of sequential indicator simulation to characterize geostatistical uncertainty

    International Nuclear Information System (INIS)

    Hansen, K.M.

    1992-10-01

    Sequential indicator simulation (SIS) is a geostatistical technique designed to aid in the characterization of uncertainty about the structure or behavior of natural systems. This report discusses a simulation experiment designed to study the quality of uncertainty bounds generated using SIS. The results indicate that, while SIS may produce reasonable uncertainty bounds in many situations, factors like the number and location of available sample data, the quality of variogram models produced by the user, and the characteristics of the geologic region to be modeled, can all have substantial effects on the accuracy and precision of estimated confidence limits. It is recommended that users of SIS conduct validation studies for the technique on their particular regions of interest before accepting the output uncertainty bounds

  8. A simple automated procedure for thiol measurement in human serum samples Procedimento automatizado simples para determinação de tióis em amostras de soro humano

    Directory of Open Access Journals (Sweden)

    Carolina M. da Costa

    2006-10-01

    Full Text Available Thiol groups have been described as the main responsible for antioxidative effects of plasmatic proteins. Also, thiol serum levels have shown a positive correlation with total antioxidant capacity (TAC in many studies. Measurement of TAC by substract oxidation-based methods have been widely used as a reference to measure antioxidant status; however, in many cases these methods are inexact or imprecise, usually when performed by manual procedures. In this paper we describe a simple automated procedure for the determination of total thiols in serum, which was based on Ellman’s method. It was correlated with several markers of oxidative/antioxidative status, such as TAC and thiobarbituric acid reactive substance test (TBARs. Serum thiol levels were correlated positively with TAC (r = 0.298, p Os tióis são descritos como os principais responsáveis pelos efeitos antioxidantes das proteínas plasmáticas. Além disso, diversos estudos mostram uma correlação positiva entre os níveis séricos de tióis e a capacidade antioxidante total (CAT. A medida da CAT por métodos baseados na oxidação de substratos tem sido amplamente usada como referência na estimativa da capacidade antioxidante em amostras biológicas; porém, em muitos casos esses métodos são inexatos e imprecisos, principalmente quando realizados por procedimentos não-automatizados. Neste artigo descrevemos um procedimento automatizado simples para a determinação de tióis totais no soro, com base no conhecido método de Ellman. A dosagem dos tióis foi correlacionada com diversos marcadores da capacidade oxidante/antioxidante, como a CAT, o teste das substâncias reativas ao ácido tiobarbitúrico (TBARs e os níveis de peróxidos totais. Os tióis correlacionaram-se positivamente com a CAT (r = 0,298; p < 0,001 e negativamente com os níveis de TBARs (r = - 0,330; p < 0,001. O procedimento aqui descrito para a dosagem de tióis pode ser uma ferramenta importante na medida da

  9. [Serum glycosaminoglycans in Graves' disease patients].

    Science.gov (United States)

    Winsz-Szczotka, Katarzyna B; Olczyk, Krystyna Z; Koźma, Ewa M; Komosińska-Vassev, Katarzyna B; Wisowski, Grzegorz R; Marcisz, Czesław

    2006-01-01

    The aim of the study was to determine the blood serum sulfated glycosaminoglycans (GAGs) and hyaluronic acid (HA) concentration of Graves' disease patients before treatment and after attainment of the euthyroid state. The study was carried out on the blood serum obtained from 17 patients with newly recognised Graves' disease and from the same patients after attainment of the euthyroid state. Graves' patients had not any clinical symptoms neither of ophthalmopathy nor pretibial myxedema. GAGs were isolated from the blood serum by the multistage extraction and purification using papaine hydrolysis, alkali elimination, as well as cetylpyridium chloride binding. Total amount of GAGs was quantified by the hexuronic acids assay. HA content in obtained GAGs sample was evaluated by the ELISA method. Increased serum concentration of sulfated GAGs in non-treated Graves' disease patients was found. Similarly, serum HA level in untreated patients was significantly elevated. The attainment of euthyroid state was accompanied by the decreased serum sulfated GAGs level and by normalization of serum HA concentration. In conclusion, the results obtained demonstrate that the alterations of GAGs metabolism connected with Graves' disease can lead to systemic changes of the extracellular matrix properties.

  10. On Locally Most Powerful Sequential Rank Tests

    Czech Academy of Sciences Publication Activity Database

    Kalina, Jan

    2017-01-01

    Roč. 36, č. 1 (2017), s. 111-125 ISSN 0747-4946 R&D Projects: GA ČR GA17-07384S Grant - others:Nadační fond na podporu vědy(CZ) Neuron Institutional support: RVO:67985556 Keywords : nonparametric test s * sequential ranks * stopping variable Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.339, year: 2016 http://library.utia.cas.cz/separaty/2017/SI/kalina-0474065.pdf

  11. Decoding restricted participation in sequential electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    Knaut, Andreas; Paschmann, Martin

    2017-06-15

    Restricted participation in sequential markets may cause high price volatility and welfare losses. In this paper we therefore analyze the drivers of restricted participation in the German intraday auction which is a short-term electricity market with quarter-hourly products. Applying a fundamental electricity market model with 15-minute temporal resolution, we identify the lack of sub-hourly market coupling being the most relevant driver of restricted participation. We derive a proxy for price volatility and find that full market coupling may trigger quarter-hourly price volatility to decrease by a factor close to four.

  12. THE DEVELOPMENT OF SPECIAL SEQUENTIALLY-TIMED

    Directory of Open Access Journals (Sweden)

    Stanislav LICHOROBIEC

    2016-06-01

    Full Text Available This article documents the development of the noninvasive use of explosives during the destruction of ice mass in river flows. The system of special sequentially-timed charges utilizes the increase in efficiency of cutting charges by covering them with bags filled with water, while simultaneously increasing the effect of the entire system of timed charges. Timing, spatial combinations during placement, and the linking of these charges results in the loosening of ice barriers on a frozen waterway, while at the same time regulating the size of the ice fragments. The developed charges will increase the operability and safety of IRS units.

  13. Pass-transistor asynchronous sequential circuits

    Science.gov (United States)

    Whitaker, Sterling R.; Maki, Gary K.

    1989-01-01

    Design methods for asynchronous sequential pass-transistor circuits, which result in circuits that are hazard- and critical-race-free and which have added degrees of freedom for the input signals, are discussed. The design procedures are straightforward and easy to implement. Two single-transition-time state assignment methods are presented, and hardware bounds for each are established. A surprising result is that the hardware realizations for each next state variable and output variable is identical for a given flow table. Thus, a state machine with N states and M outputs can be constructed using a single layout replicated N + M times.

  14. A sequential/parallel track selector

    CERN Document Server

    Bertolino, F; Bressani, Tullio; Chiavassa, E; Costa, S; Dellacasa, G; Gallio, M; Musso, A

    1980-01-01

    A medium speed ( approximately 1 mu s) hardware pre-analyzer for the selection of events detected in four planes of drift chambers in the magnetic field of the Omicron Spectrometer at the CERN SC is described. Specific geometrical criteria determine patterns of hits in the four planes of vertical wires that have to be recognized and that are stored as patterns of '1's in random access memories. Pairs of good hits are found sequentially, then the RAMs are used as look-up tables. (6 refs).

  15. Boundary conditions in random sequential adsorption

    Science.gov (United States)

    Cieśla, Michał; Ziff, Robert M.

    2018-04-01

    The influence of different boundary conditions on the density of random packings of disks is studied. Packings are generated using the random sequential adsorption algorithm with three different types of boundary conditions: periodic, open, and wall. It is found that the finite size effects are smallest for periodic boundary conditions, as expected. On the other hand, in the case of open and wall boundaries it is possible to introduce an effective packing size and a constant correction term to significantly improve the packing densities.

  16. Automatic synthesis of sequential control schemes

    International Nuclear Information System (INIS)

    Klein, I.

    1993-01-01

    Of all hard- and software developed for industrial control purposes, the majority is devoted to sequential, or binary valued, control and only a minor part to classical linear control. Typically, the sequential parts of the controller are invoked during startup and shut-down to bring the system into its normal operating region and into some safe standby region, respectively. Despite its importance, fairly little theoretical research has been devoted to this area, and sequential control programs are therefore still created manually without much theoretical support to obtain a systematic approach. We propose a method to create sequential control programs automatically. The main ideas is to spend some effort off-line modelling the plant, and from this model generate the control strategy, that is the plan. The plant is modelled using action structures, thereby concentrating on the actions instead of the states of the plant. In general the planning problem shows exponential complexity in the number of state variables. However, by focusing on the actions, we can identify problem classes as well as algorithms such that the planning complexity is reduced to polynomial complexity. We prove that these algorithms are sound, i.e., the generated solution will solve the stated problem, and complete, i.e., if the algorithms fail, then no solution exists. The algorithms generate a plan as a set of actions and a partial order on this set specifying the execution order. The generated plant is proven to be minimal and maximally parallel. For a larger class of problems we propose a method to split the original problem into a number of simple problems that can each be solved using one of the presented algorithms. It is also shown how a plan can be translated into a GRAFCET chart, and to illustrate these ideas we have implemented a planing tool, i.e., a system that is able to automatically create control schemes. Such a tool can of course also be used on-line if it is fast enough. This

  17. From sequential to parallel programming with patterns

    CERN Document Server

    CERN. Geneva

    2018-01-01

    To increase in both performance and efficiency, our programming models need to adapt to better exploit modern processors. The classic idioms and patterns for programming such as loops, branches or recursion are the pillars of almost every code and are well known among all programmers. These patterns all have in common that they are sequential in nature. Embracing parallel programming patterns, which allow us to program for multi- and many-core hardware in a natural way, greatly simplifies the task of designing a program that scales and performs on modern hardware, independently of the used programming language, and in a generic way.

  18. Simultaneous optimization of sequential IMRT plans

    International Nuclear Information System (INIS)

    Popple, Richard A.; Prellop, Perri B.; Spencer, Sharon A.; Santos, Jennifer F. de los; Duan, Jun; Fiveash, John B.; Brezovich, Ivan A.

    2005-01-01

    Radiotherapy often comprises two phases, in which irradiation of a volume at risk for microscopic disease is followed by a sequential dose escalation to a smaller volume either at a higher risk for microscopic disease or containing only gross disease. This technique is difficult to implement with intensity modulated radiotherapy, as the tolerance doses of critical structures must be respected over the sum of the two plans. Techniques that include an integrated boost have been proposed to address this problem. However, clinical experience with such techniques is limited, and many clinicians are uncomfortable prescribing nonconventional fractionation schemes. To solve this problem, we developed an optimization technique that simultaneously generates sequential initial and boost IMRT plans. We have developed an optimization tool that uses a commercial treatment planning system (TPS) and a high level programming language for technical computing. The tool uses the TPS to calculate the dose deposition coefficients (DDCs) for optimization. The DDCs were imported into external software and the treatment ports duplicated to create the boost plan. The initial, boost, and tolerance doses were specified and used to construct cost functions. The initial and boost plans were optimized simultaneously using a gradient search technique. Following optimization, the fluence maps were exported to the TPS for dose calculation. Seven patients treated using sequential techniques were selected from our clinical database. The initial and boost plans used to treat these patients were developed independently of each other by dividing the tolerance doses proportionally between the initial and boost plans and then iteratively optimizing the plans until a summation that met the treatment goals was obtained. We used the simultaneous optimization technique to generate plans that met the original planning goals. The coverage of the initial and boost target volumes in the simultaneously optimized

  19. Comparison of Sequential and Variational Data Assimilation

    Science.gov (United States)

    Alvarado Montero, Rodolfo; Schwanenberg, Dirk; Weerts, Albrecht

    2017-04-01

    Data assimilation is a valuable tool to improve model state estimates by combining measured observations with model simulations. It has recently gained significant attention due to its potential in using remote sensing products to improve operational hydrological forecasts and for reanalysis purposes. This has been supported by the application of sequential techniques such as the Ensemble Kalman Filter which require no additional features within the modeling process, i.e. it can use arbitrary black-box models. Alternatively, variational techniques rely on optimization algorithms to minimize a pre-defined objective function. This function describes the trade-off between the amount of noise introduced into the system and the mismatch between simulated and observed variables. While sequential techniques have been commonly applied to hydrological processes, variational techniques are seldom used. In our believe, this is mainly attributed to the required computation of first order sensitivities by algorithmic differentiation techniques and related model enhancements, but also to lack of comparison between both techniques. We contribute to filling this gap and present the results from the assimilation of streamflow data in two basins located in Germany and Canada. The assimilation introduces noise to precipitation and temperature to produce better initial estimates of an HBV model. The results are computed for a hindcast period and assessed using lead time performance metrics. The study concludes with a discussion of the main features of each technique and their advantages/disadvantages in hydrological applications.

  20. Time scale of random sequential adsorption.

    Science.gov (United States)

    Erban, Radek; Chapman, S Jonathan

    2007-04-01

    A simple multiscale approach to the diffusion-driven adsorption from a solution to a solid surface is presented. The model combines two important features of the adsorption process: (i) The kinetics of the chemical reaction between adsorbing molecules and the surface and (ii) geometrical constraints on the surface made by molecules which are already adsorbed. The process (i) is modeled in a diffusion-driven context, i.e., the conditional probability of adsorbing a molecule provided that the molecule hits the surface is related to the macroscopic surface reaction rate. The geometrical constraint (ii) is modeled using random sequential adsorption (RSA), which is the sequential addition of molecules at random positions on a surface; one attempt to attach a molecule is made per one RSA simulation time step. By coupling RSA with the diffusion of molecules in the solution above the surface the RSA simulation time step is related to the real physical time. The method is illustrated on a model of chemisorption of reactive polymers to a virus surface.

  1. Hybrid Computerized Adaptive Testing: From Group Sequential Design to Fully Sequential Design

    Science.gov (United States)

    Wang, Shiyu; Lin, Haiyan; Chang, Hua-Hua; Douglas, Jeff

    2016-01-01

    Computerized adaptive testing (CAT) and multistage testing (MST) have become two of the most popular modes in large-scale computer-based sequential testing. Though most designs of CAT and MST exhibit strength and weakness in recent large-scale implementations, there is no simple answer to the question of which design is better because different…

  2. Sequential and simultaneous choices: testing the diet selection and sequential choice models.

    Science.gov (United States)

    Freidin, Esteban; Aw, Justine; Kacelnik, Alex

    2009-03-01

    We investigate simultaneous and sequential choices in starlings, using Charnov's Diet Choice Model (DCM) and Shapiro, Siller and Kacelnik's Sequential Choice Model (SCM) to integrate function and mechanism. During a training phase, starlings encountered one food-related option per trial (A, B or R) in random sequence and with equal probability. A and B delivered food rewards after programmed delays (shorter for A), while R ('rejection') moved directly to the next trial without reward. In this phase we measured latencies to respond. In a later, choice, phase, birds encountered the pairs A-B, A-R and B-R, the first implementing a simultaneous choice and the second and third sequential choices. The DCM predicts when R should be chosen to maximize intake rate, and SCM uses latencies of the training phase to predict choices between any pair of options in the choice phase. The predictions of both models coincided, and both successfully predicted the birds' preferences. The DCM does not deal with partial preferences, while the SCM does, and experimental results were strongly correlated to this model's predictions. We believe that the SCM may expose a very general mechanism of animal choice, and that its wider domain of success reflects the greater ecological significance of sequential over simultaneous choices.

  3. Competitive radioimmunoassay of digoxin in serum

    International Nuclear Information System (INIS)

    Oslapas, Raymond; Herrin, T.R.

    1975-01-01

    The process described is for determining the digoxin level of a serum. To do so a mixture is made by adding to the serum sample an antidigoxin antibody and a suitable labelling quantity of O 3 -(hydroxy-4 phenethylcarbamoyl)digoxigenin for radioactive labelling. The mixture is allowed to incubate so that the digoxin of the sample and the radioactive labelling reagent joint to the antidigoxin antibody. A precipitating agent is added to the mixture to help the formation of a precipitate and thus separate the labelled digoxin taken up from the precipitate free digoxin. The liquid is separated from the precipitate formed and the residual radioactivity of the precipitate is measured [fr

  4. Use of disposable open tubular ion exchange pre-columns for in-line clean-up of serum and plasma samples prior to capillary electrophoretic analysis of inorganic cations

    Czech Academy of Sciences Publication Activity Database

    Kiplagat, I.K.; Doan, T.K.O.; Kubáň, Pavel; Kubáň, P.; Boček, Petr

    2011-01-01

    Roč. 1218, č. 6 (2011), s. 856-859 ISSN 0021-9673 R&D Projects: GA ČR GAP206/10/1219 Institutional research plan: CEZ:AV0Z40310501 Keywords : sample treatment * capillary electrophoresis * biological samples Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.531, year: 2011

  5. Robust real-time pattern matching using bayesian sequential hypothesis testing.

    Science.gov (United States)

    Pele, Ofir; Werman, Michael

    2008-08-01

    This paper describes a method for robust real time pattern matching. We first introduce a family of image distance measures, the "Image Hamming Distance Family". Members of this family are robust to occlusion, small geometrical transforms, light changes and non-rigid deformations. We then present a novel Bayesian framework for sequential hypothesis testing on finite populations. Based on this framework, we design an optimal rejection/acceptance sampling algorithm. This algorithm quickly determines whether two images are similar with respect to a member of the Image Hamming Distance Family. We also present a fast framework that designs a near-optimal sampling algorithm. Extensive experimental results show that the sequential sampling algorithm performance is excellent. Implemented on a Pentium 4 3 GHz processor, detection of a pattern with 2197 pixels, in 640 x 480 pixel frames, where in each frame the pattern rotated and was highly occluded, proceeds at only 0.022 seconds per frame.

  6. Effects of cysteamine on pituitary, MTTW15 tumor, and serum prolactin levels measured by rat lymphoma cell bioassay and radioimmunoassay

    International Nuclear Information System (INIS)

    Parsons, J.A.; Peterson, E.K.; Hartfel, M.A.

    1984-01-01

    Cysteamine (CSH), a sulfhydryl compound, reduces both serum and anterior pituitary (AP) PRL measured by RIA. We have used the Nb2 lymphoma cell bioassay (BIO) for PRL to evaluate possible CSH-related changes in PRL levels in sera and tissues of male and MtTW15 mammosomatotropic tumor-bearing female rats. Experimental animals received a single sc injection of CSH (300 mg/kg), and samples were collected 0.5-24 h later. Since CSH and serum from CSH rats were toxic in BIO, samples were dialyzed before assay. All samples were evaluated for PRL and GH by RIA as well. A significant decrease (P less than 0.05) in BIO serum PRL was evident in male rats 0.5 h after CSH; levels remained low for 24 h. Serum PRL by RIA was significantly depressed at 4 h but not at 0.5 h or 24 h. PRL in AP extracts was decreased (60-90%) at all times by BIO and RIA. Significant decreases of BIO- and RIA-detectable PRL were recorded in serum and tissues (AP and tumors) at 4 h in tumor rats. Sequentially bled (0.5-4 h) CSH-treated tumor-bearing rats showed 50% and 80% reductions in serum PRL at 1 and 4 h by both BIO and RIA. CSH had no effect on GH levels in sera and tissues of any animal studied at any time interval. Our results substantiate earlier reports on CSH-induced decreases in RIA-detectable PRL. They show that such changes cannot be attributed to assay effects alone, as significant decreases in circulating and stored PRL (both AP and tumor) were evident by BIO. Results with tissue extracts were the most dramatic. They suggest an action of CSH or a metabolic intermediate with stored PRL which reduces both extractable PRL and hormone release. Such an effect of CSH on PRL extraction has been suggested by others. Whatever the mechanism, it appears to be relatively specific, since GH cells were not affected

  7. Sequential probability ratio controllers for safeguards radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.L.; Nixon, K.V.

    1984-01-01

    Sequential hypothesis tests applied to nuclear safeguards accounting methods make the methods more sensitive to detecting diversion. The sequential tests also improve transient signal detection in safeguards radiation monitors. This paper describes three microprocessor control units with sequential probability-ratio tests for detecting transient increases in radiation intensity. The control units are designed for three specific applications: low-intensity monitoring with Poisson probability ratios, higher intensity gamma-ray monitoring where fixed counting intervals are shortened by sequential testing, and monitoring moving traffic where the sequential technique responds to variable-duration signals. The fixed-interval controller shortens a customary 50-s monitoring time to an average of 18 s, making the monitoring delay less bothersome. The controller for monitoring moving vehicles benefits from the sequential technique by maintaining more than half its sensitivity when the normal passage speed doubles

  8. Equivalence between quantum simultaneous games and quantum sequential games

    OpenAIRE

    Kobayashi, Naoki

    2007-01-01

    A framework for discussing relationships between different types of games is proposed. Within the framework, quantum simultaneous games, finite quantum simultaneous games, quantum sequential games, and finite quantum sequential games are defined. In addition, a notion of equivalence between two games is defined. Finally, the following three theorems are shown: (1) For any quantum simultaneous game G, there exists a quantum sequential game equivalent to G. (2) For any finite quantum simultaneo...

  9. Discrimination between sequential and simultaneous virtual channels with electrical hearing

    OpenAIRE

    Landsberger, David; Galvin, John J.

    2011-01-01

    In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation mode...

  10. C-quence: a tool for analyzing qualitative sequential data.

    Science.gov (United States)

    Duncan, Starkey; Collier, Nicholson T

    2002-02-01

    C-quence is a software application that matches sequential patterns of qualitative data specified by the user and calculates the rate of occurrence of these patterns in a data set. Although it was designed to facilitate analyses of face-to-face interaction, it is applicable to any data set involving categorical data and sequential information. C-quence queries are constructed using a graphical user interface. The program does not limit the complexity of the sequential patterns specified by the user.

  11. Tailored sequential drug release from bilayered calcium sulfate composites

    International Nuclear Information System (INIS)

    Orellana, Bryan R.; Puleo, David A.

    2014-01-01

    The current standard for treating infected bony defects, such as those caused by periodontal disease, requires multiple time-consuming steps and often multiple procedures to fight the infection and recover lost tissue. Releasing an antibiotic followed by an osteogenic agent from a synthetic bone graft substitute could allow for a streamlined treatment, reducing the need for multiple surgeries and thereby shortening recovery time. Tailorable bilayered calcium sulfate (CS) bone graft substitutes were developed with the ability to sequentially release multiple therapeutic agents. Bilayered composite samples having a shell and core geometry were fabricated with varying amounts (1 or 10 wt.%) of metronidazole-loaded poly(lactic-co-glycolic acid) (PLGA) particles embedded in the shell and simvastatin directly loaded into either the shell, core, or both. Microcomputed tomography showed the overall layered geometry as well as the uniform distribution of PLGA within the shells. Dissolution studies demonstrated that the amount of PLGA particles (i.e., 1 vs. 10 wt.%) had a small but significant effect on the erosion rate (3% vs. 3.4%/d). Mechanical testing determined that introducing a layered geometry had a significant effect on the compressive strength, with an average reduction of 35%, but properties were comparable to those of mandibular trabecular bone. Sustained release of simvastatin directly loaded into CS demonstrated that changing the shell to core volume ratio dictates the duration of drug release from each layer. When loaded together in the shell or in separate layers, sequential release of metronidazole and simvastatin was achieved. By introducing a tunable, layered geometry capable of releasing multiple drugs, CS-based bone graft substitutes could be tailored in order to help streamline the multiple steps needed to regenerate tissue in infected defects. - Highlights: • Bilayered CS composites were fabricated as potential bone graft substitutes. • The shell

  12. Tailored sequential drug release from bilayered calcium sulfate composites

    Energy Technology Data Exchange (ETDEWEB)

    Orellana, Bryan R.; Puleo, David A., E-mail: puleo@uky.edu

    2014-10-01

    The current standard for treating infected bony defects, such as those caused by periodontal disease, requires multiple time-consuming steps and often multiple procedures to fight the infection and recover lost tissue. Releasing an antibiotic followed by an osteogenic agent from a synthetic bone graft substitute could allow for a streamlined treatment, reducing the need for multiple surgeries and thereby shortening recovery time. Tailorable bilayered calcium sulfate (CS) bone graft substitutes were developed with the ability to sequentially release multiple therapeutic agents. Bilayered composite samples having a shell and core geometry were fabricated with varying amounts (1 or 10 wt.%) of metronidazole-loaded poly(lactic-co-glycolic acid) (PLGA) particles embedded in the shell and simvastatin directly loaded into either the shell, core, or both. Microcomputed tomography showed the overall layered geometry as well as the uniform distribution of PLGA within the shells. Dissolution studies demonstrated that the amount of PLGA particles (i.e., 1 vs. 10 wt.%) had a small but significant effect on the erosion rate (3% vs. 3.4%/d). Mechanical testing determined that introducing a layered geometry had a significant effect on the compressive strength, with an average reduction of 35%, but properties were comparable to those of mandibular trabecular bone. Sustained release of simvastatin directly loaded into CS demonstrated that changing the shell to core volume ratio dictates the duration of drug release from each layer. When loaded together in the shell or in separate layers, sequential release of metronidazole and simvastatin was achieved. By introducing a tunable, layered geometry capable of releasing multiple drugs, CS-based bone graft substitutes could be tailored in order to help streamline the multiple steps needed to regenerate tissue in infected defects. - Highlights: • Bilayered CS composites were fabricated as potential bone graft substitutes. • The shell

  13. Impact of controlling the sum of error probability in the sequential probability ratio test

    Directory of Open Access Journals (Sweden)

    Bijoy Kumarr Pradhan

    2013-05-01

    Full Text Available A generalized modified method is proposed to control the sum of error probabilities in sequential probability ratio test to minimize the weighted average of the two average sample numbers under a simple null hypothesis and a simple alternative hypothesis with the restriction that the sum of error probabilities is a pre-assigned constant to find the optimal sample size and finally a comparison is done with the optimal sample size found from fixed sample size procedure. The results are applied to the cases when the random variate follows a normal law as well as Bernoullian law.

  14. Estimation of polyclonal IgG4 hybrids in normal human serum.

    Science.gov (United States)

    Young, Elizabeth; Lock, Emma; Ward, Douglas G; Cook, Alexander; Harding, Stephen; Wallis, Gregg L F

    2014-07-01

    The in vivo or in vitro formation of IgG4 hybrid molecules, wherein the immunoglobulins have exchanged half molecules, has previously been reported under experimental conditions. Here we estimate the incidence of polyclonal IgG4 hybrids in normal human serum and comment on the existence of IgG4 molecules with different immunoglobulin light chains. Polyclonal IgG4 was purified from pooled or individual donor human sera and sequentially fractionated using light-chain affinity and size exclusion chromatography. Fractions were analysed by SDS-PAGE, immunoblotting, ELISA, immunodiffusion and matrix-assisted laser-desorption mass spectrometry. Polyclonal IgG4 purified from normal serum contained IgG4κ, IgG4λ and IgG4κ/λ molecules. Size exclusion chromatography showed that IgG4 was principally present in monomeric form (150 000 MW). SDS-PAGE, immunoblotting and ELISA showed the purity of the three IgG4 samples. Immunodiffusion, light-chain sandwich ELISA and mass spectrometry demonstrated that both κ and λ light chains were present on only the IgG4κ/λ molecules. The amounts of IgG4κ/λ hybrid molecules ranged from 21 to 33% from the five sera analysed. Based on the molecular weight these molecules were formed of two IgG4 heavy chains plus one κ and one λ light chain. Polyclonal IgG (IgG4-depleted) was similarly fractionated according to light-chain specificity. No evidence of hybrid IgG κ/λ antibodies was observed. These results indicate that hybrid IgG4κ/λ antibodies compose a substantial portion of IgG4 from normal human serum. © 2014 John Wiley & Sons Ltd.

  15. A novel modified electrode as GC/PPy-AuNPs-rGO/L-Cys/Ag@MUA nanostructure configuration for determination of CCP and CRP antibodies in human blood serum samples.

    Science.gov (United States)

    Babakhanian, Arash; Ehzari, Hosna; Kaki, Samineh; Hamidi, Zohreh

    2015-01-15

    In this work, silver nanoparticles were synthesized and stabilized with 11-mercaptoundecanoateanions to produce a new Ag@MUA core shell structure, and its utilizing for fabrication of a new sensing film. Gold nanoparticles (AuNPs) were electrochemically produced and simultaneously immobilized into the electropolymerized polypyrrole (PPy) film with the reduced graphene oxide (rGO). The Ag@MUA was then grafted to the surface of GC/PPy-AuNPs-rGO film using L-cysteine (L-Cys) linker agent and trifluoromethanesulfonic anhydride (TF2O), at ambient temperature and under the electrode stirring. The characterization of the sensor was studied by scanning electron microscopy, electrochemical impedance spectroscopy, cyclic and square wave voltammetry techniques. The utility of the modified electrode for clinical diagnosis has been successfully demonstrated by the analysis of human blood serums with a certified CRP and CCP content. Thus, the proposed sensor shows simple preparation, accuracy and precision in the analysis of cytochrome c protein (CCP) and C-reactive protein (CRP (with less side interferences. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Discrimination between sequential and simultaneous virtual channels with electrical hearing.

    Science.gov (United States)

    Landsberger, David; Galvin, John J

    2011-09-01

    In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation modes. For sequential VCs, the interpulse interval (IPI) varied between 0.0 and 1.8 ms. All stimuli were presented at comfortably loud, loudness-balanced levels at a 250 pulse per second per electrode (ppse) stimulation rate. On average, CI subjects were able to reliably discriminate between sequential and simultaneous VCs. While there was no significant effect of IPI or stimulation mode on VC discrimination, some subjects exhibited better VC discrimination with BP + 1 stimulation. Subjects' discrimination between sequential and simultaneous VCs was correlated with electrode discrimination, suggesting that spatial selectivity may influence perception of sequential VCs. To maintain equal loudness, sequential VC amplitudes were nearly double those of simultaneous VCs, presumably resulting in a broader spread of excitation. These results suggest that perceptual differences between simultaneous and sequential VCs might be explained by differences in the spread of excitation. © 2011 Acoustical Society of America

  17. Lineup composition, suspect position, and the sequential lineup advantage.

    Science.gov (United States)

    Carlson, Curt A; Gronlund, Scott D; Clark, Steven E

    2008-06-01

    N. M. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001) argued that sequential lineups reduce the likelihood of mistaken eyewitness identification. Experiment 1 replicated the design of R. C. L. Lindsay and G. L. Wells (1985), the first study to show the sequential lineup advantage. However, the innocent suspect was chosen at a lower rate in the simultaneous lineup, and no sequential lineup advantage was found. This led the authors to hypothesize that protection from a sequential lineup might emerge only when an innocent suspect stands out from the other lineup members. In Experiment 2, participants viewed a simultaneous or sequential lineup with either the guilty suspect or 1 of 3 innocent suspects. Lineup fairness was varied to influence the degree to which a suspect stood out. A sequential lineup advantage was found only for the unfair lineups. Additional analyses of suspect position in the sequential lineups showed an increase in the diagnosticity of suspect identifications as the suspect was placed later in the sequential lineup. These results suggest that the sequential lineup advantage is dependent on lineup composition and suspect position. (c) 2008 APA, all rights reserved

  18. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...

  19. Sequential determination of actinides in a variety of matrices

    International Nuclear Information System (INIS)

    Olsen, S.C.

    2002-01-01

    A large number of analytical procedures for the actinides have been published, each catering for a specific need. Due to the bioassay programme in our laboratory, a need arose for a method to determine natural (Th and U) and anthropogenic actinides (Np, Pu and Am/Cm) together in a variety of samples. The method would have to be suitable for routine application: simple, inexpensive, rapid and robust. In some cases, the amount of material available is not sufficient for the determination of separate groups of actinides, and a sequential separation and measurement of the analytes would therefore be required. The types of matrices vary from aqueous samples to radiological surveillance (urine and faeces) to environmental studies (soil, sediment and fish), but the separation procedure should be able to service all of these. The working range of the method would have to cater for lower levels of the transuranium actinides in particular sample types containing higher levels of the natural actinides (U and Th). The first analytical problem to be discussed, is how to get the different sample types into the same loading solution required by a single separation approach. This entails sample dissolution or decomposition in some cases, and pre-concentration or pre-separation in others. A separation scheme is presented for the clean separation of all the actinides in a form suitable for alpha spectrometry. The development of a single column separation of the analytes of interest are looked at, as well as observations made during the development of the separation scheme, such as concentration effects. Results for test samples and certified reference materials are be presented. (author)

  20. Les terrains jurassiques du sondage de Couy (Cher, France. Leur analyse séquentielle détaillée à partir de la description des carottes et des courbes diagraphiques Jurassic Formations in the Couy Borehole (Cher Department, France. Their Detailed Sequential Analysis from the Core Sample Descriptions and Well-Logging Curves

    Directory of Open Access Journals (Sweden)

    Gely J. P.

    2006-11-01

    (Lorenz et al. , 1987 make this borehole a first-rate stratigraphic reference concerning the Lower and Middle Jurassic series in the southern part of the Paris Basin. The lithostratigraphic analysis has already been the subject of a publication (Lorenz et al. , 1992, and a description of the sequences has been sketched out (Gely and Lorenz, 1991. At the same time, the implementation of lithostratigraphic data and the description of the well logs provide greater accuracy in interpretation in terms of desposit sequences, while the stratigraphic calibration of the well-log signatures gives a reference on the scale of the Paris Basin. The sequences defined in the Couy borehole are compared to the ones already published elsewhere on a global scale (Haq et al. , 1988; Vail et al. , 1987 and on a regional scale (Rioult et al. , 1991; Gonnin et al. , 1992, 1993; Bessereau and Guillocheau, 1994, (Figs. 2 and 3. Discontinuities corresponding to a sedimentation gap are usually represented by traces of bioturbation or by perforations in the top surface of a bed or else by a surface of gullying. In other cases, the sequence boundaries do not seem to be so clearly expressed but correspond to highly bioturbated bands, a single limestone bed in the midst of marls or perhaps an abrupt lithological change. For a limestone bed situated at the upper boundary of a sequence, we can see that this latter is often perforated or bioturbated. This enables them to be distinguished from other limestone levels situated at the transgressive maximum, and which contain pelagic fossils or authigenic minerals. On well logs, these two types of beds often have a comparable signature. The sequence boundaries are clearly shown by the well logs, which show clearcut curve breaks and are often capable of orienting or confirming the choice of identification criteria of the boundaries in the core samples. However, it can be seen that there is no direct relationships between the visible size of the discontinuity and

  1. Sequential infiltration synthesis for advanced lithography

    Energy Technology Data Exchange (ETDEWEB)

    Darling, Seth B.; Elam, Jeffrey W.; Tseng, Yu-Chih; Peng, Qing

    2017-10-10

    A plasma etch resist material modified by an inorganic protective component via sequential infiltration synthesis (SIS) and methods of preparing the modified resist material. The modified resist material is characterized by an improved resistance to a plasma etching or related process relative to the unmodified resist material, thereby allowing formation of patterned features into a substrate material, which may be high-aspect ratio features. The SIS process forms the protective component within the bulk resist material through a plurality of alternating exposures to gas phase precursors which infiltrate the resist material. The plasma etch resist material may be initially patterned using photolithography, electron-beam lithography or a block copolymer self-assembly process.

  2. Clinical evaluation of synthetic aperture sequential beamforming

    DEFF Research Database (Denmark)

    Hansen, Peter Møller; Hemmsen, Martin Christian; Lange, Theis

    2012-01-01

    In this study clinically relevant ultrasound images generated with synthetic aperture sequential beamforming (SASB) is compared to images generated with a conventional technique. The advantage of SASB is the ability to produce high resolution ultrasound images with a high frame rate and at the same...... time massively reduce the amount of generated data. SASB was implemented in a system consisting of a conventional ultrasound scanner connected to a PC via a research interface. This setup enables simultaneous recording with both SASB and conventional technique. Eighteen volunteers were ultrasound...... scanned abdominally, and 84 sequence pairs were recorded. Each sequence pair consists of two simultaneous recordings of the same anatomical location with SASB and conventional B-mode imaging. The images were evaluated in terms of spatial resolution, contrast, unwanted artifacts, and penetration depth...

  3. Sequential cooling insert for turbine stator vane

    Science.gov (United States)

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  4. Gleason-Busch theorem for sequential measurements

    Science.gov (United States)

    Flatt, Kieran; Barnett, Stephen M.; Croke, Sarah

    2017-12-01

    Gleason's theorem is a statement that, given some reasonable assumptions, the Born rule used to calculate probabilities in quantum mechanics is essentially unique [A. M. Gleason, Indiana Univ. Math. J. 6, 885 (1957), 10.1512/iumj.1957.6.56050]. We show that Gleason's theorem contains within it also the structure of sequential measurements, and along with this the state update rule. We give a small set of axioms, which are physically motivated and analogous to those in Busch's proof of Gleason's theorem [P. Busch, Phys. Rev. Lett. 91, 120403 (2003), 10.1103/PhysRevLett.91.120403], from which the familiar Kraus operator form follows. An axiomatic approach has practical relevance as well as fundamental interest, in making clear those assumptions which underlie the security of quantum communication protocols. Interestingly, the two-time formalism is seen to arise naturally in this approach.

  5. Sequential Stereotype Priming: A Meta-Analysis.

    Science.gov (United States)

    Kidder, Ciara K; White, Katherine R; Hinojos, Michelle R; Sandoval, Mayra; Crites, Stephen L

    2017-08-01

    Psychological interest in stereotype measurement has spanned nearly a century, with researchers adopting implicit measures in the 1980s to complement explicit measures. One of the most frequently used implicit measures of stereotypes is the sequential priming paradigm. The current meta-analysis examines stereotype priming, focusing specifically on this paradigm. To contribute to ongoing discussions regarding methodological rigor in social psychology, one primary goal was to identify methodological moderators of the stereotype priming effect-whether priming is due to a relation between the prime and target stimuli, the prime and target response, participant task, stereotype dimension, stimulus onset asynchrony (SOA), and stimuli type. Data from 39 studies yielded 87 individual effect sizes from 5,497 participants. Analyses revealed that stereotype priming is significantly moderated by the presence of prime-response relations, participant task, stereotype dimension, target stimulus type, SOA, and prime repetition. These results carry both practical and theoretical implications for future research on stereotype priming.

  6. Sequential Acral Lentiginous Melanomas of the Foot

    Directory of Open Access Journals (Sweden)

    Jiro Uehara

    2010-12-01

    Full Text Available A 64-year-old Japanese woman had a lightly brown-blackish pigmented macule (1.2 cm in diameter on the left sole of her foot. She received surgical excision following a diagnosis of acral lentiginous melanoma (ALM, which was confirmed histopathologically. One month after the operation, a second melanoma lesion was noticed adjacent to the grafted site. Histopathologically, the two lesions had no continuity, but HMB-45 and cyclin D1 double-positive cells were detected not only on aggregates of atypical melanocytes but also on single cells near the cutting edge of the first lesion. The unique occurrence of a sequential lesion of a primary melanoma might be caused by stimulated subclinical field cells during the wound healing process following the initial operation. This case warrants further investigation to establish the appropriate surgical margin of ALM lesions.

  7. Dancing Twins: Stellar Hierarchies That Formed Sequentially?

    Science.gov (United States)

    Tokovinin, Andrei

    2018-04-01

    This paper draws attention to the class of resolved triple stars with moderate ratios of inner and outer periods (possibly in a mean motion resonance) and nearly circular, mutually aligned orbits. Moreover, stars in the inner pair are twins with almost identical masses, while the mass sum of the inner pair is comparable to the mass of the outer component. Such systems could be formed either sequentially (inside-out) by disk fragmentation with subsequent accretion and migration, or by a cascade hierarchical fragmentation of a rotating cloud. Orbits of the outer and inner subsystems are computed or updated in four such hierarchies: LHS 1070 (GJ 2005, periods 77.6 and 17.25 years), HIP 9497 (80 and 14.4 years), HIP 25240 (1200 and 47.0 years), and HIP 78842 (131 and 10.5 years).

  8. Sequential Therapy in Metastatic Renal Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Bradford R Hirsch

    2016-04-01

    Full Text Available The treatment of metastatic renal cell carcinoma (mRCC has changed dramatically in the past decade. As the number of available agents, and related volume of research, has grown, it is increasingly complex to know how to optimally treat patients. The authors are practicing medical oncologists at the US Oncology Network, the largest community-based network of oncology providers in the country, and represent the leadership of the Network's Genitourinary Research Committee. We outline our thought process in approaching sequential therapy of mRCC and the use of real-world data to inform our approach. We also highlight the evolving literature that will impact practicing oncologists in the near future.

  9. Microstructure history effect during sequential thermomechanical processing

    International Nuclear Information System (INIS)

    Yassar, Reza S.; Murphy, John; Burton, Christina; Horstemeyer, Mark F.; El kadiri, Haitham; Shokuhfar, Tolou

    2008-01-01

    The key to modeling the material processing behavior is the linking of the microstructure evolution to its processing history. This paper quantifies various microstructural features of an aluminum automotive alloy that undergoes sequential thermomechanical processing which is comprised hot rolling of a 150-mm billet to a 75-mm billet, rolling to 3 mm, annealing, and then cold rolling to a 0.8-mm thickness sheet. The microstructural content was characterized by means of electron backscatter diffraction, scanning electron microscopy, and transmission electron microscopy. The results clearly demonstrate the evolution of precipitate morphologies, dislocation structures, and grain orientation distributions. These data can be used to improve material models that claim to capture the history effects of the processing materials

  10. Prosody and alignment: a sequential perspective

    Science.gov (United States)

    Szczepek Reed, Beatrice

    2010-12-01

    In their analysis of a corpus of classroom interactions in an inner city high school, Roth and Tobin describe how teachers and students accomplish interactional alignment by prosodically matching each other's turns. Prosodic matching, and specific prosodic patterns are interpreted as signs of, and contributions to successful interactional outcomes and positive emotions. Lack of prosodic matching, and other specific prosodic patterns are interpreted as features of unsuccessful interactions, and negative emotions. This forum focuses on the article's analysis of the relation between interpersonal alignment, emotion and prosody. It argues that prosodic matching, and other prosodic linking practices, play a primarily sequential role, i.e. one that displays the way in which participants place and design their turns in relation to other participants' turns. Prosodic matching, rather than being a conversational action in itself, is argued to be an interactional practice (Schegloff 1997), which is not always employed for the accomplishment of `positive', or aligning actions.

  11. Maldi-Tof /Tof-MS Reveals Elevated Serum Haptoglobin and Amyloid A in Behcet's Disease

    NARCIS (Netherlands)

    Mao, L.; Dong, H.; Yang, P.; Zhou, H.; Huang, X.; Lin, X.; Kijlstra, A.

    2008-01-01

    Behcet¿s disease (BD) is a multisystemic autoimmune disease with unclear etiology and pathogenesis. To screen aberrant serum proteins in BD, serum samples were obtained from eight male BD patients with active uveitis and eight male healthy volunteers with informed consent. The serum samples from

  12. Monitoring sequential electron transfer with EPR

    International Nuclear Information System (INIS)

    Thurnauer, M.C.; Feezel, L.L.; Snyder, S.W.; Tang, J.; Norris, J.R.; Morris, A.L.; Rustandi, R.R.

    1989-01-01

    A completely general model which treats electron spin polarization (ESP) found in a system in which radical pairs with different magnetic interactions are formed sequentially has been described. This treatment has been applied specifically to the ESP found in the bacterial reaction center. Test cases show clearly how parameters such as structure, lifetime, and magnetic interactions within the successive radical pairs affect the ESP, and demonstrate that previous treatments of this problem have been incomplete. The photosynthetic bacterial reaction center protein is an ideal system for testing the general model of ESP. The radical pair which exhibits ESP, P 870 + Q - (P 870 + is the oxidized, primary electron donor, a bacteriochlorophyll special pair and Q - is the reduced, primary quinone acceptor) is formed via sequential electron transport through the intermediary radical pair P 870 + I - (I - is the reduced, intermediary electron acceptor, a bacteriopheophytin). In addition, it is possible to experimentally vary most of the important parameters, such as the lifetime of the intermediary radical pair and the magnetic interactions in each pair. It has been shown how selective isotopic substitution ( 1 H or 2 H) on P 870 , I and Q affects the ESP of the EPR spectrum of P 870 + Q - , observed at two different microwave frequencies, in Fe 2+ -depleted bacterial reaction centers of Rhodobacter sphaeroides R26. Thus, the relative magnitudes of the magnetic properties (nuclear hyperfine and g-factor differences) which influence ESP development were varied. The results support the general model of ESP in that they suggest that the P 870 + Q - radical pair interactions are the dominant source of ESP production in 2 H bacterial reaction centers

  13. Assessing potential forest and steel inter-industry residue utilisation by sequential chemical extraction

    Energy Technology Data Exchange (ETDEWEB)

    Makela, M.

    2012-10-15

    Traditional process industries in Finland and abroad are facing an emerging waste disposal problem due recent regulatory development which has increased the costs of landfill disposal and difficulty in acquiring new sites. For large manufacturers, such as the forest and ferrous metals industries, symbiotic cooperation of formerly separate industrial sectors could enable the utilisation waste-labeled residues in manufacturing novel residue-derived materials suitable for replacing commercial virgin alternatives. Such efforts would allow transforming the current linear resource use and disposal models to more cyclical ones and thus attain savings in valuable materials and energy resources. The work described in this thesis was aimed at utilising forest and carbon steel industry residues in the experimental manufacture of novel residue-derived materials technically and environmentally suitable for amending agricultural or forest soil properties. Single and sequential chemical extractions were used to compare the pseudo-total concentrations of trace elements in the manufactured amendment samples to relevant Finnish statutory limit values for the use of fertilizer products and to assess respective potential availability under natural conditions. In addition, the quality of analytical work and the suitability of sequential extraction in the analysis of an industrial solid sample were respectively evaluated through the analysis of a certified reference material and by X-ray diffraction of parallel sequential extraction residues. According to the acquired data, the incorporation of both forest and steel industry residues, such as fly ashes, lime wastes, green liquor dregs, sludges and slags, led to amendment liming capacities (34.9-38.3%, Ca equiv., d.w.) comparable to relevant commercial alternatives. Only the first experimental samples showed increased concentrations of pseudo-total cadmium and chromium, of which the latter was specified as the trivalent Cr(III). Based on

  14. Association between serum soluble CD30 and serum creatinine before and after renal transplantation.

    Science.gov (United States)

    López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M

    2008-11-01

    There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.

  15. Simultaneous sequential monitoring of efficacy and safety led to masking of effects.

    Science.gov (United States)

    van Eekelen, Rik; de Hoop, Esther; van der Tweel, Ingeborg

    2016-08-01

    Usually, sequential designs for clinical trials are applied on the primary (=efficacy) outcome. In practice, other outcomes (e.g., safety) will also be monitored and influence the decision whether to stop a trial early. Implications of simultaneous monitoring on trial decision making are yet unclear. This study examines what happens to the type I error, power, and required sample sizes when one efficacy outcome and one correlated safety outcome are monitored simultaneously using sequential designs. We conducted a simulation study in the framework of a two-arm parallel clinical trial. Interim analyses on two outcomes were performed independently and simultaneously on the same data sets using four sequential monitoring designs, including O'Brien-Fleming and Triangular Test boundaries. Simulations differed in values for correlations and true effect sizes. When an effect was present in both outcomes, competition was introduced, which decreased power (e.g., from 80% to 60%). Futility boundaries for the efficacy outcome reduced overall type I errors as well as power for the safety outcome. Monitoring two correlated outcomes, given that both are essential for early trial termination, leads to masking of true effects. Careful consideration of scenarios must be taken into account when designing sequential trials. Simulation results can help guide trial design. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study

    International Nuclear Information System (INIS)

    Ghaye, B.; Dondelinger, R.F.; Dewe, W.

    1999-01-01

    The aim of this study was to evaluate in a prospective and randomized study spiral versus sequential scanning in the guidance of percutaneous lung biopsy. Fifty thoracic lesions occurring in 48 patients were biopsied by a senior and a junior operator. Six different time segments of the procedure were measured. Scanning mode versus length of procedure, pathological results, irradiation and complications were evaluated. Total duration of the procedure and of the first sampling was significantly longer with spiral CT for the senior operator (p < 0.004). No significant time difference was observed for the junior operator. Diameter of the lesion, depth of location, position of the patient and needle entry site did not influence the results. The sensitivity was 90.9, specificity 100, positive predictive value 100 and negative predictive value 60 % for spiral CT, and 94.7, 100, 100 and 85.7 % for sequential CT, respectively. Eleven pneumothoraces and ten perinodular hemorrhages were seen with spiral CT and six and ten, respectively, with sequential CT. The mean dose of irradiation was 4027 mAs for spiral CT and 2358 mAs for conventional CT. Spiral CT does neither reduce procedure time nor the rate of complications. Pathological results do not differ compared with sequential CT, and total dose of irradiation is higher with spiral scanning. (orig.)

  17. Two-step sequential pretreatment for the enhanced enzymatic hydrolysis of coffee spent waste.

    Science.gov (United States)

    Ravindran, Rajeev; Jaiswal, Swarna; Abu-Ghannam, Nissreen; Jaiswal, Amit K

    2017-09-01

    In the present study, eight different pretreatments of varying nature (physical, chemical and physico-chemical) followed by a sequential, combinatorial pretreatment strategy was applied to spent coffee waste to attain maximum sugar yield. Pretreated samples were analysed for total reducing sugar, individual sugars and generation of inhibitory compounds such as furfural and hydroxymethyl furfural (HMF) which can hinder microbial growth and enzyme activity. Native spent coffee waste was high in hemicellulose content. Galactose was found to be the predominant sugar in spent coffee waste. Results showed that sequential pretreatment yielded 350.12mg of reducing sugar/g of substrate, which was 1.7-fold higher than in native spent coffee waste (203.4mg/g of substrate). Furthermore, extensive delignification was achieved using sequential pretreatment strategy. XRD, FTIR, and DSC profiles of the pretreated substrates were studied to analyse the various changes incurred in sequentially pretreated spent coffee waste as opposed to native spent coffee waste. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Value of serum tenascin-C in patients with acute myocardial infarction

    African Journals Online (AJOL)

    Rania Gaber

    2015-10-09

    Oct 9, 2015 ... Aliquots of serum were delivered into Eppendorf tubes. Serum samples have been .... Tenascin-C induced by aldosterone-mediated inflammation. J · Cardiovasc .... nosis estimation and targeted therapy. Cell Adh Migr 2015 ...

  19. Modified sequential extraction for biochar and petroleum coke: Metal release potential and its environmental implications.

    Science.gov (United States)

    von Gunten, Konstantin; Alam, Md Samrat; Hubmann, Magdalena; Ok, Yong Sik; Konhauser, Kurt O; Alessi, Daniel S

    2017-07-01

    A modified Community Bureau of Reference (CBR) sequential extraction method was tested to assess the composition of untreated pyrogenic carbon (biochar) and oil sands petroleum coke. Wood biochar samples were found to contain lower concentrations of metals, but had higher fractions of easily mobilized alkaline earth and transition metals. Sewage sludge biochar was determined to be less recalcitrant and had higher total metal concentrations, with most of the metals found in the more resilient extraction fractions (oxidizable, residual). Petroleum coke was the most stable material, with a similar metal distribution pattern as the sewage sludge biochar. The applied sequential extraction method represents a suitable technique to recover metals from these materials, and is a valuable tool in understanding the metal retaining and leaching capability of various biochar types and carbonaceous petroleum coke samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Campbell and moment measures for finite sequential spatial processes

    NARCIS (Netherlands)

    M.N.M. van Lieshout (Marie-Colette)

    2006-01-01

    textabstractWe define moment and Campbell measures for sequential spatial processes, prove a Campbell-Mecke theorem, and relate the results to their counterparts in the theory of point processes. In particular, we show that any finite sequential spatial process model can be derived as the vector

  1. Simultaneous versus sequential penetrating keratoplasty and cataract surgery.

    Science.gov (United States)

    Hayashi, Ken; Hayashi, Hideyuki

    2006-10-01

    To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.

  2. Reading Remediation Based on Sequential and Simultaneous Processing.

    Science.gov (United States)

    Gunnison, Judy; And Others

    1982-01-01

    The theory postulating a dichotomy between sequential and simultaneous processing is reviewed and its implications for remediating reading problems are reviewed. Research is cited on sequential-simultaneous processing for early and advanced reading. A list of remedial strategies based on the processing dichotomy addresses decoding and lexical…

  3. Induction of simultaneous and sequential malolactic fermentation in durian wine.

    Science.gov (United States)

    Taniasuri, Fransisca; Lee, Pin-Rou; Liu, Shao-Quan

    2016-08-02

    This study represented for the first time the impact of malolactic fermentation (MLF) induced by Oenococcus oeni and its inoculation strategies (simultaneous vs. sequential) on the fermentation performance as well as aroma compound profile of durian wine. There was no negative impact of simultaneous inoculation of O. oeni and Saccharomyces cerevisiae on the growth and fermentation kinetics of S. cerevisiae as compared to sequential fermentation. Simultaneous MLF did not lead to an excessive increase in volatile acidity as compared to sequential MLF. The kinetic changes of organic acids (i.e. malic, lactic, succinic, acetic and α-ketoglutaric acids) varied with simultaneous and sequential MLF relative to yeast alone. MLF, regardless of inoculation mode, resulted in higher production of fermentation-derived volatiles as compared to control (alcoholic fermentation only), including esters, volatile fatty acids, and terpenes, except for higher alcohols. Most indigenous volatile sulphur compounds in durian were decreased to trace levels with little differences among the control, simultaneous and sequential MLF. Among the different wines, the wine with simultaneous MLF had higher concentrations of terpenes and acetate esters while sequential MLF had increased concentrations of medium- and long-chain ethyl esters. Relative to alcoholic fermentation only, both simultaneous and sequential MLF reduced acetaldehyde substantially with sequential MLF being more effective. These findings illustrate that MLF is an effective and novel way of modulating the volatile and aroma compound profile of durian wine. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. A Survey of Multi-Objective Sequential Decision-Making

    NARCIS (Netherlands)

    Roijers, D.M.; Vamplew, P.; Whiteson, S.; Dazeley, R.

    2013-01-01

    Sequential decision-making problems with multiple objectives arise naturally in practice and pose unique challenges for research in decision-theoretic planning and learning, which has largely focused on single-objective settings. This article surveys algorithms designed for sequential

  5. Dynamics-based sequential memory: Winnerless competition of patterns

    International Nuclear Information System (INIS)

    Seliger, Philip; Tsimring, Lev S.; Rabinovich, Mikhail I.

    2003-01-01

    We introduce a biologically motivated dynamical principle of sequential memory which is based on winnerless competition (WLC) of event images. This mechanism is implemented in a two-layer neural model of sequential spatial memory. We present the learning dynamics which leads to the formation of a WLC network. After learning, the system is capable of associative retrieval of prerecorded sequences of patterns

  6. Sequential, progressive, equal-power, reflective beam-splitter arrays

    Science.gov (United States)

    Manhart, Paul K.

    2017-11-01

    The equations to calculate equal-power reflectivity of a sequential series of beam splitters is presented. Non-sequential optical design examples are offered for uniform illumination using diode lasers. Objects created using Boolean operators and Swept Surfaces can create objects capable of reflecting light into predefined elevation and azimuth angles. Analysis of the illumination patterns for the array are also presented.

  7. The sequential price of anarchy for atomic congestion games

    NARCIS (Netherlands)

    de Jong, Jasper; Uetz, Marc Jochen; Liu, Tie-Yan; Qi, Qi; Ye, Yinyu

    2014-01-01

    In situations without central coordination, the price of anarchy relates the quality of any Nash equilibrium to the quality of a global optimum. Instead of assuming that all players choose their actions simultaneously, we consider games where players choose their actions sequentially. The sequential

  8. Quantum Probability Zero-One Law for Sequential Terminal Events

    Science.gov (United States)

    Rehder, Wulf

    1980-07-01

    On the basis of the Jauch-Piron quantum probability calculus a zero-one law for sequential terminal events is proven, and the significance of certain crucial axioms in the quantum probability calculus is discussed. The result shows that the Jauch-Piron set of axioms is appropriate for the non-Boolean algebra of sequential events.

  9. Lineup Composition, Suspect Position, and the Sequential Lineup Advantage

    Science.gov (United States)

    Carlson, Curt A.; Gronlund, Scott D.; Clark, Steven E.

    2008-01-01

    N. M. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001) argued that sequential lineups reduce the likelihood of mistaken eyewitness identification. Experiment 1 replicated the design of R. C. L. Lindsay and G. L. Wells (1985), the first study to show the sequential lineup advantage. However, the innocent suspect was chosen at a lower rate…

  10. Accounting for Heterogeneous Returns in Sequential Schooling Decisions

    NARCIS (Netherlands)

    Zamarro, G.

    2006-01-01

    This paper presents a method for estimating returns to schooling that takes into account that returns may be heterogeneous among agents and that educational decisions are made sequentially.A sequential decision model is interesting because it explicitly considers that the level of education of each

  11. An exploratory sequential design to validate measures of moral emotions.

    Science.gov (United States)

    Márquez, Margarita G; Delgado, Ana R

    2017-05-01

    This paper presents an exploratory and sequential mixed methods approach in validating measures of knowledge of the moral emotions of contempt, anger and disgust. The sample comprised 60 participants in the qualitative phase when a measurement instrument was designed. Item stems, response options and correction keys were planned following the results obtained in a descriptive phenomenological analysis of the interviews. In the quantitative phase, the scale was used with a sample of 102 Spanish participants, and the results were analysed with the Rasch model. In the qualitative phase, salient themes included reasons, objects and action tendencies. In the quantitative phase, good psychometric properties were obtained. The model fit was adequate. However, some changes had to be made to the scale in order to improve the proportion of variance explained. Substantive and methodological im-plications of this mixed-methods study are discussed. Had the study used a single re-search method in isolation, aspects of the global understanding of contempt, anger and disgust would have been lost.

  12. Serum protein fingerprint of patients with gastric cancer by SELDI ...

    African Journals Online (AJOL)

    To study the serum protein fingerprint of patients with gastric cancer and to screen for protein molecules closely related to gastric cancer during the onset and progression of the disease using surface-enhanced laser desorption and ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Serum samples from 80 gastric ...

  13. Radioimmunoassay of haloperidol in human serum: correlation of serum haloperidol with serum prolactin

    International Nuclear Information System (INIS)

    Poland, R.E.; Rubin, R.T.

    1981-01-01

    A radioimmunoassay (RIA) for measurement of serum haloperidol is described. Compared to gaschromatography (GC), RIA vaues average 40% higher. However, a simple organic extraction of serum yields statistically equivalent RIA and GC haloperidol determinations. For both men and women combined, there was a positive correlation between dose (mg/kg/day) and steady-state serum haloperidol level (r = +0.86) and between steady-state serum haloperidol and serum prolactin (PRL) concentration

  14. Simulation based sequential Monte Carlo methods for discretely observed Markov processes

    OpenAIRE

    Neal, Peter

    2014-01-01

    Parameter estimation for discretely observed Markov processes is a challenging problem. However, simulation of Markov processes is straightforward using the Gillespie algorithm. We exploit this ease of simulation to develop an effective sequential Monte Carlo (SMC) algorithm for obtaining samples from the posterior distribution of the parameters. In particular, we introduce two key innovations, coupled simulations, which allow us to study multiple parameter values on the basis of a single sim...

  15. Quantitative determination of albumin in microlitre amounts of rat serum: With a short note on serum albumin levels in ageing rats

    NARCIS (Netherlands)

    Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.; Hollander, C.F.

    1967-01-01

    A simple dye binding method for determining rat serum albumin, which employs the anionic dye 2-(4′-hydroxybenzneeazo) benzoic acid (HBABA) is described. Albumin in 5μ1 of serum is determined colorimetrically. Purified rat albumin is used as a primary standard and rat serum as a reference sample.

  16. Serum YKL-40

    DEFF Research Database (Denmark)

    Mylin, Anne K; Abildgaard, Niels; Johansen, Julia S

    2015-01-01

    to clinical progression, i.e. skeletal-related events (SREs), in 230 newly diagnosed patients with multiple myeloma receiving intravenous bisphosphonates. Serum concentrations of YKL-40 and biochemical bone markers (CTX-MMP, CTX-I, PINP) were measured at diagnosis. Patients were evaluated every third month...

  17. 79 - 81_Wali - Serum

    African Journals Online (AJOL)

    DR. AMINU

    2013-06-01

    Jun 1, 2013 ... SERUM ANTIOXIDANT VITAMINS LEVELS IN CHILDREN WITH SICKLE. CELL ANAEMIA IN ... play a role in the development of sickle cell anaemic complications. In the current study, ... vaso-occlusive episodes, acute chest syndrome and impaired ... frequency of sickling crises accompanied by tissue or.

  18. Analysis of serum angiotensin-converting enzyme.

    Science.gov (United States)

    Muller, B R

    2002-09-01

    Serum angiotensin-converting enzyme (SACE) levels are influenced by genetic polymorphism. Interpretation of serum levels with the appropriate genotypic reference range improves the diagnostic sensitivity of the assay for sarcoidosis. SACE assays are performed by a large number of routine clinical laboratories. However, there is no external quality assessment (EQA) for SACE other than an informal regional scheme. This showed analytical performance of SACE assays to be poor, with a diversity of reference ranges, leading to widely disparate clinical classification of EQA samples. Genetic polymorphism combined with poor analytical performance suggest that perhaps SACE assays should revert to being the province of specialized laboratories.

  19. Impact of sequential proton density fat fraction for quantification of hepatic steatosis in nonalcoholic fatty liver disease.

    Science.gov (United States)

    Idilman, Ilkay S; Keskin, Onur; Elhan, Atilla Halil; Idilman, Ramazan; Karcaaltincaba, Musturay

    2014-05-01

    To determine the utility of sequential MRI-estimated proton density fat fraction (MRI-PDFF) for quantification of the longitudinal changes in liver fat content in individuals with nonalcoholic fatty liver disease (NAFLD). A total of 18 consecutive individuals (M/F: 10/8, mean age: 47.7±9.8 years) diagnosed with NAFLD, who underwent sequential PDFF calculations for the quantification of hepatic steatosis at two different time points, were included in the study. All patients underwent T1-independent volumetric multi-echo gradient-echo imaging with T2* correction and spectral fat modeling. A close correlation for quantification of hepatic steatosis between the initial MRI-PDFF and liver biopsy was observed (rs=0.758, phepatic steatosis. The changes in serum ALT levels significantly reflected changes in MRI-PDFF in patients with NAFLD.

  20. Multiple sample, radioactive particle counting apparatus

    International Nuclear Information System (INIS)

    Reddy, R.R.V.; Kelso, D.M.

    1978-01-01

    An apparatus is described for determining the respective radioactive particle sample count being emitted from radioactive particle containing samples. It includes means for modulating the information on the radioactive particles being emitted from the samples, coded detecting means for sequentially detecting different respective coded combinations of the radioactive particles emitted from more than one but less than all of the samples, and processing the modulated information to derive the sample count for each sample. It includes a single light emitting crystal next to a number of samples, an encoder belt sequentially movable between the crystal and the samples. The encoder belt has a coded array of apertures to provide corresponding modulated light pulses from the crystal, and a photomultiplier tube to convert the modulated light pulses to decodable electrical signals for deriving the respective sample count