WorldWideScience

Sample records for sequential k-space acquisition

  1. Time-resolved 3D pulmonary perfusion MRI: comparison of different k-space acquisition strategies at 1.5 and 3 T.

    Science.gov (United States)

    Attenberger, Ulrike I; Ingrisch, Michael; Dietrich, Olaf; Herrmann, Karin; Nikolaou, Konstantin; Reiser, Maximilian F; Schönberg, Stefan O; Fink, Christian

    2009-09-01

    Time-resolved pulmonary perfusion MRI requires both high temporal and spatial resolution, which can be achieved by using several nonconventional k-space acquisition techniques. The aim of this study is to compare the image quality of time-resolved 3D pulmonary perfusion MRI with different k-space acquisition techniques in healthy volunteers at 1.5 and 3 T. Ten healthy volunteers underwent contrast-enhanced time-resolved 3D pulmonary MRI on 1.5 and 3 T using the following k-space acquisition techniques: (a) generalized autocalibrating partial parallel acquisition (GRAPPA) with an internal acquisition of reference lines (IRS), (b) GRAPPA with a single "external" acquisition of reference lines (ERS) before the measurement, and (c) a combination of GRAPPA with an internal acquisition of reference lines and view sharing (VS). The spatial resolution was kept constant at both field strengths to exclusively evaluate the influences of the temporal resolution achieved with the different k-space sampling techniques on image quality. The temporal resolutions were 2.11 seconds IRS, 1.31 seconds ERS, and 1.07 VS at 1.5 T and 2.04 seconds IRS, 1.30 seconds ERS, and 1.19 seconds VS at 3 T.Image quality was rated by 2 independent radiologists with regard to signal intensity, perfusion homogeneity, artifacts (eg, wrap around, noise), and visualization of pulmonary vessels using a 3 point scale (1 = nondiagnostic, 2 = moderate, 3 = good). Furthermore, the signal-to-noise ratio in the lungs was assessed. At 1.5 T the lowest image quality (sum score: 154) was observed for the ERS technique and the highest quality for the VS technique (sum score: 201). In contrast, at 3 T images acquired with VS were hampered by strong artifacts and image quality was rated significantly inferior (sum score: 137) compared with IRS (sum score: 180) and ERS (sum score: 174). Comparing 1.5 and 3 T, in particular the overall rating of the IRS technique (sum score: 180) was very similar at both field

  2. Topological properties of function spaces $C_k(X,2)$ over zero-dimensional metric spaces $X$

    OpenAIRE

    Gabriyelyan, S.

    2015-01-01

    Let $X$ be a zero-dimensional metric space and $X'$ its derived set. We prove the following assertions: (1) the space $C_k(X,2)$ is an Ascoli space iff $C_k(X,2)$ is $k_\\mathbb{R}$-space iff either $X$ is locally compact or $X$ is not locally compact but $X'$ is compact, (2) $C_k(X,2)$ is a $k$-space iff either $X$ is a topological sum of a Polish locally compact space and a discrete space or $X$ is not locally compact but $X'$ is compact, (3) $C_k(X,2)$ is a sequential space iff $X$ is a Pol...

  3. Sequential Generalized Transforms on Function Space

    Directory of Open Access Journals (Sweden)

    Jae Gil Choi

    2013-01-01

    Full Text Available We define two sequential transforms on a function space Ca,b[0,T] induced by generalized Brownian motion process. We then establish the existence of the sequential transforms for functionals in a Banach algebra of functionals on Ca,b[0,T]. We also establish that any one of these transforms acts like an inverse transform of the other transform. Finally, we give some remarks about certain relations between our sequential transforms and other well-known transforms on Ca,b[0,T].

  4. Off-resonance artifacts correction with convolution in k-space (ORACLE).

    Science.gov (United States)

    Lin, Wei; Huang, Feng; Simonotto, Enrico; Duensing, George R; Reykowski, Arne

    2012-06-01

    Off-resonance artifacts hinder the wider applicability of echo-planar imaging and non-Cartesian MRI methods such as radial and spiral. In this work, a general and rapid method is proposed for off-resonance artifacts correction based on data convolution in k-space. The acquired k-space is divided into multiple segments based on their acquisition times. Off-resonance-induced artifact within each segment is removed by applying a convolution kernel, which is the Fourier transform of an off-resonance correcting spatial phase modulation term. The field map is determined from the inverse Fourier transform of a basis kernel, which is calibrated from data fitting in k-space. The technique was demonstrated in phantom and in vivo studies for radial, spiral and echo-planar imaging datasets. For radial acquisitions, the proposed method allows the self-calibration of the field map from the imaging data, when an alternating view-angle ordering scheme is used. An additional advantage for off-resonance artifacts correction based on data convolution in k-space is the reusability of convolution kernels to images acquired with the same sequence but different contrasts. Copyright © 2011 Wiley-Liss, Inc.

  5. Self-calibrated correlation imaging with k-space variant correlation functions.

    Science.gov (United States)

    Li, Yu; Edalati, Masoud; Du, Xingfu; Wang, Hui; Cao, Jie J

    2018-03-01

    Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation functions. Because of Fourier encoding with gradients, outer k-space data contain higher spatial-frequency image components arising primarily from tissue boundaries. As a result of tissue-boundary sparsity in the human anatomy, neighboring k-space data correlation varies from the central to the outer k-space. By estimating k-space variant correlation functions with an iterative self-calibration method, correlation imaging can benefit from neighboring k-space data correlation associated with both coil sensitivity encoding and tissue-boundary sparsity, thereby providing a speed gain over parallel imaging that relies only on coil sensitivity encoding. This new approach is investigated in brain imaging and free-breathing neonatal cardiac imaging. Correlation imaging performs better than existing parallel imaging techniques in simulated brain imaging acceleration experiments. The higher speed enables real-time data acquisition for neonatal cardiac imaging in which physiological motion is fast and non-periodic. With k-space variant correlation functions, correlation imaging gives a higher speed than parallel imaging and offers the potential to image physiological motion in real-time. Magn Reson Med 79:1483-1494, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Four dimensional magnetic resonance imaging with retrospective k-space reordering: A feasibility study

    International Nuclear Information System (INIS)

    Liu, Yilin; Yin, Fang-Fang; Cai, Jing; Chen, Nan-kuei; Chu, Mei-Lan

    2015-01-01

    Purpose: Current four dimensional magnetic resonance imaging (4D-MRI) techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of a new strategy for 4D-MRI which is based on retrospective k-space reordering. Methods: We simulated a k-space reordered 4D-MRI on a 4D digital extended cardiac-torso (XCAT) human phantom. A 2D echo planar imaging MRI sequence [frame rate (F) = 0.448 Hz; image resolution (R) = 256 × 256; number of k-space segments (N KS ) = 4] with sequential image acquisition mode was assumed for the simulation. Image quality of the simulated “4D-MRI” acquired from the XCAT phantom was qualitatively evaluated, and tumor motion trajectories were compared to input signals. In particular, mean absolute amplitude differences (D) and cross correlation coefficients (CC) were calculated. Furthermore, to evaluate the data sufficient condition for the new 4D-MRI technique, a comprehensive simulation study was performed using 30 cancer patients’ respiratory profiles to study the relationships between data completeness (C p ) and a number of impacting factors: the number of repeated scans (N R ), number of slices (N S ), number of respiratory phase bins (N P ), N KS , F, R, and initial respiratory phase at image acquisition (P 0 ). As a proof-of-concept, we implemented the proposed k-space reordering 4D-MRI technique on a T2-weighted fast spin echo MR sequence and tested it on a healthy volunteer. Results: The simulated 4D-MRI acquired from the XCAT phantom matched closely to the original XCAT images. Tumor motion trajectories measured from the simulated 4D-MRI matched well with input signals (D = 0.83 and 0.83 mm, and CC = 0.998 and 0.992 in superior–inferior and anterior–posterior directions, respectively). The relationship between C p and N R was found best represented by an exponential function (C P =100(1−e −0.18N R ), when N S

  7. Sequential combination of k-t principle component analysis (PCA) and partial parallel imaging: k-t PCA GROWL.

    Science.gov (United States)

    Qi, Haikun; Huang, Feng; Zhou, Hongmei; Chen, Huijun

    2017-03-01

    k-t principle component analysis (k-t PCA) is a distinguished method for high spatiotemporal resolution dynamic MRI. To further improve the accuracy of k-t PCA, a combination with partial parallel imaging (PPI), k-t PCA/SENSE, has been tested. However, k-t PCA/SENSE suffers from long reconstruction time and limited improvement. This study aims to improve the combination of k-t PCA and PPI on both reconstruction speed and accuracy. A sequential combination scheme called k-t PCA GROWL (GRAPPA operator for wider readout line) was proposed. The GRAPPA operator was performed before k-t PCA to extend each readout line into a wider band, which improved the condition of the encoding matrix in the following k-t PCA reconstruction. k-t PCA GROWL was tested and compared with k-t PCA and k-t PCA/SENSE on cardiac imaging. k-t PCA GROWL consistently resulted in better image quality compared with k-t PCA/SENSE at high acceleration factors for both retrospectively and prospectively undersampled cardiac imaging, with a much lower computation cost. The improvement in image quality became greater with the increase of acceleration factor. By sequentially combining the GRAPPA operator and k-t PCA, the proposed k-t PCA GROWL method outperformed k-t PCA/SENSE in both reconstruction speed and accuracy, suggesting that k-t PCA GROWL is a better combination scheme than k-t PCA/SENSE. Magn Reson Med 77:1058-1067, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Image reconstruction in k-space from MR data encoded with ambiguous gradient fields.

    Science.gov (United States)

    Schultz, Gerrit; Gallichan, Daniel; Weber, Hans; Witschey, Walter R T; Honal, Matthias; Hennig, Jürgen; Zaitsev, Maxim

    2015-02-01

    In this work, the limits of image reconstruction in k-space are explored when non-bijective gradient fields are used for spatial encoding. The image space analogy between parallel imaging and imaging with non-bijective encoding fields is partially broken in k-space. As a consequence, it is hypothesized and proven that ambiguities can only be resolved partially in k-space, and not completely as is the case in image space. Image-space and k-space based reconstruction algorithms for multi-channel radiofrequency data acquisitions are programmed and tested using numerical simulations as well as in vivo measurement data. The hypothesis is verified based on an analysis of reconstructed images. It is found that non-bijective gradient fields have the effect that densely sampled autocalibration data, used for k-space reconstruction, provide less information than a separate scan of the receiver coil sensitivity maps, used for image space reconstruction. Consequently, in k-space only the undersampling artifact can be unfolded, whereas in image space, it is also possible to resolve aliasing that is caused by the non-bijectivity of the gradient fields. For standard imaging, reconstruction in image space and in k-space is nearly equivalent, whereas there is a fundamental difference with practical consequences for the selection of image reconstruction algorithms when non-bijective encoding fields are involved. © 2014 Wiley Periodicals, Inc.

  9. Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chandarana, Hersh; Block, Kai T.; Winfeld, Matthew J.; Lala, Shailee V.; Mazori, Daniel; Giuffrida, Emalyn; Babb, James S.; Milla, Sarah S. [New York University Langone Medical Center, Department of Radiology, New York, NY (United States)

    2014-02-15

    To compare the image quality of contrast-enhanced abdominopelvic 3D fat-suppressed T1-weighted gradient-echo imaging with radial and conventional Cartesian k-space acquisition schemes in paediatric patients. Seventy-three consecutive paediatric patients were imaged at 1.5 T with sequential contrast-enhanced T1-weighted Cartesian (VIBE) and radial gradient echo (GRE) acquisition schemes with matching parameters when possible. Cartesian VIBE was acquired as a breath-hold or as free breathing in patients who could not suspend respiration, followed by free-breathing radial GRE in all patients. Two paediatric radiologists blinded to the acquisition schemes evaluated multiple parameters of image quality on a five-point scale, with higher score indicating a more optimal examination. Lesion presence or absence, conspicuity and edge sharpness were also evaluated. Mixed-model analysis of variance was performed to compare radial GRE and Cartesian VIBE. Radial GRE had significantly (all P < 0.001) higher scores for overall image quality, hepatic edge sharpness, hepatic vessel clarity and respiratory motion robustness than Cartesian VIBE. More lesions were detected on radial GRE by both readers than on Cartesian VIBE, with significantly higher scores for lesion conspicuity and edge sharpness (all P < 0.001). Radial GRE has better image quality and lesion conspicuity than conventional Cartesian VIBE in paediatric patients undergoing contrast-enhanced abdominopelvic MRI. (orig.)

  10. War-gaming application for future space systems acquisition

    Science.gov (United States)

    Nguyen, Tien M.; Guillen, Andy T.

    2016-05-01

    Recently the U.S. Department of Defense (DOD) released the Defense Innovation Initiative (DII) [1] to focus DOD on five key aspects; Aspect #1: Recruit talented and innovative people, Aspect #2: Reinvigorate war-gaming, Aspect #3: Initiate long-range research and development programs, Aspect #4: Make DOD practices more innovative, and Aspect #5: Advance technology and new operational concepts. Per DII instruction, this paper concentrates on Aspect #2 and Aspect #4 by reinvigorating the war-gaming effort with a focus on an innovative approach for developing the optimum Program and Technical Baselines (PTBs) and their corresponding optimum acquisition strategies for acquiring future space systems. The paper describes a unified approach for applying the war-gaming concept for future DOD acquisition of space systems. The proposed approach includes a Unified Game-based Acquisition Framework (UGAF) and an Advanced Game-Based Mathematical Framework (AGMF) using Bayesian war-gaming engines to optimize PTB solutions and select the corresponding optimum acquisition strategies for acquiring a space system. The framework defines the action space for all players with a complete description of the elements associated with the games, including Department of Defense Acquisition Authority (DAA), stakeholders, warfighters, and potential contractors, War-Gaming Engines (WGEs) played by DAA, WGEs played by Contractor (KTR), and the players' Payoff and Cost functions (PCFs). The AGMF presented here addresses both complete and incomplete information cases. The proposed framework provides a recipe for the DAA and USAF-Space and Missile Systems Center (SMC) to acquire future space systems optimally.

  11. Fast regularizing sequential subspace optimization in Banach spaces

    International Nuclear Information System (INIS)

    Schöpfer, F; Schuster, T

    2009-01-01

    We are concerned with fast computations of regularized solutions of linear operator equations in Banach spaces in case only noisy data are available. To this end we modify recently developed sequential subspace optimization methods in such a way that the therein employed Bregman projections onto hyperplanes are replaced by Bregman projections onto stripes whose width is in the order of the noise level

  12. Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

    Science.gov (United States)

    Liu, Yilin; Yin, Fang-Fang; Rhee, DongJoo; Cai, Jing

    2016-01-01

    The authors have recently developed a cine-mode T2*/T1-weighted 4D-MRI technique and a sequential-mode T2-weighted 4D-MRI technique for imaging respiratory motion. This study aims at investigating which 4D-MRI image acquisition mode, cine or sequential, provides more accurate measurement of organ motion during respiration. A 4D digital extended cardiac-torso (XCAT) human phantom with a hypothesized tumor was used to simulate the image acquisition and the 4D-MRI reconstruction. The respiratory motion was controlled by the given breathing signal profiles. The tumor was manipulated to move continuously with the surrounding tissue. The motion trajectories were measured from both sequential- and cine-mode 4D-MRI images. The measured trajectories were compared with the average trajectory calculated from the input profiles, which was used as references. The error in 4D-MRI tumor motion trajectory (E) was determined. In addition, the corresponding respiratory motion amplitudes of all the selected 2D images for 4D reconstruction were recorded. Each of the amplitude was compared with the amplitude of its associated bin on the average breathing curve. The mean differences from the average breathing curve across all slice positions (D) were calculated. A total of 500 simulated respiratory profiles with a wide range of irregularity (Ir) were used to investigate the relationship between D and Ir. Furthermore, statistical analysis of E and D using XCAT controlled by 20 cancer patients' breathing profiles was conducted. Wilcoxon Signed Rank test was conducted to compare two modes. D increased faster for cine-mode (D = 1.17 × Ir + 0.23) than sequential-mode (D = 0.47 × Ir + 0.23) as irregularity increased. For the XCAT study using 20 cancer patients' breathing profiles, the median E values were significantly different: 0.12 and 0.10 cm for cine- and sequential-modes, respectively, with a p-value of 0.02. The median D values were significantly different: 0.47 and 0.24 cm for cine

  13. Controlling T2 blurring in 3D RARE arterial spin labeling acquisition through optimal combination of variable flip angles and k-space filtering.

    Science.gov (United States)

    Zhao, Li; Chang, Ching-Di; Alsop, David C

    2018-02-09

    To improve the SNR efficiency and reduce the T 2 blurring of 3D rapid acquisition with relaxation enhancement stack-of-spiral arterial spin labeling imaging by using variable refocusing flip angles and k-space filtering. An algorithm for determining the optimal combination of variable flip angles and filtering correction is proposed. The flip angles are designed using extended phase graph physical simulations in an analytical and global optimization framework, with an optional constraint on deposited power. Optimal designs for correcting to Hann and Fermi window functions were compared with conventional constant amplitude or variable flip angle only designs on 6 volunteers. With the Fermi window correction, the proposed optimal designs provided 39.8 and 27.3% higher SNR (P variable flip angle designs. Even when power deposition was limited to 50% of the constant amplitude design, the proposed method outperformed the SNR (P variable flip angles can be derived as the output of an optimization problem. The combined design of variable flip angle and k-space filtering provided superior SNR to designs primarily emphasizing either approach singly. © 2018 International Society for Magnetic Resonance in Medicine.

  14. Self-navigated 4D cartesian imaging of periodic motion in the body trunk using partial k-space compressed sensing.

    Science.gov (United States)

    Küstner, Thomas; Würslin, Christian; Schwartz, Martin; Martirosian, Petros; Gatidis, Sergios; Brendle, Cornelia; Seith, Ferdinand; Schick, Fritz; Schwenzer, Nina F; Yang, Bin; Schmidt, Holger

    2017-08-01

    To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A partial Fourier-like constraint compacts the sampling space to one half of k-space. The central k-space line is periodically acquired to allow an extraction of a self-navigated respiration signal used to populate a k-space of multiple breathing positions. The randomness of the acquisition (induced by periodic breathing pattern) yields a subsampled k-space that is reconstructed using compressed sensing. Local image evaluations (coefficient of variation and slope steepness through organs) reveal information about motion resolvability. Image quality is inspected by a blinded reading. Sequence and reconstruction method are made publicly available. The method is able to capture and reconstruct 4D images with high image quality and motion resolution within a short scan time of less than 2 min. These findings are supported by restricted-isometry-property analysis, local image evaluation, and blinded reading. The proposed method provides a clinical feasible setup to capture periodic respiratory motion with a fast acquisition protocol and can be extended by further surrogate signals to capture additional periodic motions. Retrospective parametrization allows for flexible tuning toward the targeted applications. Magn Reson Med 78:632-644, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  15. Two-dimensional T2 distribution mapping in rock core plugs with optimal k-space sampling.

    Science.gov (United States)

    Xiao, Dan; Balcom, Bruce J

    2012-07-01

    Spin-echo single point imaging has been employed for 1D T(2) distribution mapping, but a simple extension to 2D is challenging since the time increase is n fold, where n is the number of pixels in the second dimension. Nevertheless 2D T(2) mapping in fluid saturated rock core plugs is highly desirable because the bedding plane structure in rocks often results in different pore properties within the sample. The acquisition time can be improved by undersampling k-space. The cylindrical shape of rock core plugs yields well defined intensity distributions in k-space that may be efficiently determined by new k-space sampling patterns that are developed in this work. These patterns acquire 22.2% and 11.7% of the k-space data points. Companion density images may be employed, in a keyhole imaging sense, to improve image quality. T(2) weighted images are fit to extract T(2) distributions, pixel by pixel, employing an inverse Laplace transform. Images reconstructed with compressed sensing, with similar acceleration factors, are also presented. The results show that restricted k-space sampling, in this application, provides high quality results. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Optimizing monoscopic kV fluoro acquisition for prostate intrafraction motion evaluation

    International Nuclear Information System (INIS)

    Adamson, Justus; Wu Qiuwen

    2009-01-01

    Monoscopic kV imaging during radiotherapy has been recently implemented for prostate intrafraction motion evaluation. However, the accuracy of 3D localization techniques from monoscopic imaging of prostate and the effect of acquisition parameters on the 3D accuracy have not been studied in detail, with imaging dose remaining a concern. In this paper, we investigate methods to optimize the kV acquisition parameters and imaging protocol to achieve improved 3D localization and 2D image registration accuracy for minimal imaging dose. Prostate motion during radiotherapy was simulated using existing cine-MRI measurements, and was used to investigate the accuracy of various 3D localization techniques and the effect of the kV acquisition protocol. We also investigated the relationship between mAs and the accuracy of the 2D image registration for localization of fiducial markers and we measured imaging dose for a 30 cm diameter phantom to evaluate the necessary dose to achieve acceptable image registration accuracy. Simulations showed that the error in assuming the shortest path to localize the prostate in 3D using monoscopic imaging during a typical IMRT fraction will be less than ∼1.5 mm for 95% of localizations, and will also depend on prostate motion distribution, treatment duration and image acquisition and treatment protocol. Most uncertainty cannot be reduced from higher imaging frequency or acquiring during gantry rotation between beams. Measured maximum surface dose to the cylindrical phantom from monoscopic kV intrafraction acquisitions varied between 0.4 and 5.5 mGy, depending on the acquisition protocol, and was lower than the required dose for CBCT (21.1 mGy). Imaging dose can be lowered by ∼15-40% when mAs is optimized with acquisition angle. Images acquired during MV beam delivery require increased mAs to obtain the same level of registration accuracy, with mAs/registration increasing roughly linearly with field size and dose rate.

  17. Four-channel surface coil array for sequential CW-EPR image acquisition

    Science.gov (United States)

    Enomoto, Ayano; Emoto, Miho; Fujii, Hirotada; Hirata, Hiroshi

    2013-09-01

    This article describes a four-channel surface coil array to increase the area of visualization for continuous-wave electron paramagnetic resonance (CW-EPR) imaging. A 776-MHz surface coil array was constructed with four independent surface coil resonators and three kinds of switches. Control circuits for switching the resonators were also built to sequentially perform EPR image acquisition for each resonator. The resonance frequencies of the resonators were shifted using PIN diode switches to decouple the inductively coupled coils. To investigate the area of visualization with the surface coil array, three-dimensional EPR imaging was performed using a glass cell phantom filled with a solution of nitroxyl radicals. The area of visualization obtained with the surface coil array was increased approximately 3.5-fold in comparison to that with a single surface coil resonator. Furthermore, to demonstrate the applicability of this surface coil array to animal imaging, three-dimensional EPR imaging was performed in a living mouse with an exogenously injected nitroxyl radical imaging agent.

  18. Simultaneous acquisition of 2D and 3D solid-state NMR experiments for sequential assignment of oriented membrane protein samples

    Energy Technology Data Exchange (ETDEWEB)

    Gopinath, T. [University of Minnesota, Department of Biochemistry, Molecular Biology, and Biophysics (United States); Mote, Kaustubh R. [University of Minnesota, Department of Chemistry (United States); Veglia, Gianluigi, E-mail: vegli001@umn.edu [University of Minnesota, Department of Biochemistry, Molecular Biology, and Biophysics (United States)

    2015-05-15

    We present a new method called DAISY (Dual Acquisition orIented ssNMR spectroScopY) for the simultaneous acquisition of 2D and 3D oriented solid-state NMR experiments for membrane proteins reconstituted in mechanically or magnetically aligned lipid bilayers. DAISY utilizes dual acquisition of sine and cosine dipolar or chemical shift coherences and long living {sup 15}N longitudinal polarization to obtain two multi-dimensional spectra, simultaneously. In these new experiments, the first acquisition gives the polarization inversion spin exchange at the magic angle (PISEMA) or heteronuclear correlation (HETCOR) spectra, the second acquisition gives PISEMA-mixing or HETCOR-mixing spectra, where the mixing element enables inter-residue correlations through {sup 15}N–{sup 15}N homonuclear polarization transfer. The analysis of the two 2D spectra (first and second acquisitions) enables one to distinguish {sup 15}N–{sup 15}N inter-residue correlations for sequential assignment of membrane proteins. DAISY can be implemented in 3D experiments that include the polarization inversion spin exchange at magic angle via I spin coherence (PISEMAI) sequence, as we show for the simultaneous acquisition of 3D PISEMAI–HETCOR and 3D PISEMAI–HETCOR-mixing experiments.

  19. Simultaneous acquisition of 2D and 3D solid-state NMR experiments for sequential assignment of oriented membrane protein samples.

    Science.gov (United States)

    Gopinath, T; Mote, Kaustubh R; Veglia, Gianluigi

    2015-05-01

    We present a new method called DAISY (Dual Acquisition orIented ssNMR spectroScopY) for the simultaneous acquisition of 2D and 3D oriented solid-state NMR experiments for membrane proteins reconstituted in mechanically or magnetically aligned lipid bilayers. DAISY utilizes dual acquisition of sine and cosine dipolar or chemical shift coherences and long living (15)N longitudinal polarization to obtain two multi-dimensional spectra, simultaneously. In these new experiments, the first acquisition gives the polarization inversion spin exchange at the magic angle (PISEMA) or heteronuclear correlation (HETCOR) spectra, the second acquisition gives PISEMA-mixing or HETCOR-mixing spectra, where the mixing element enables inter-residue correlations through (15)N-(15)N homonuclear polarization transfer. The analysis of the two 2D spectra (first and second acquisitions) enables one to distinguish (15)N-(15)N inter-residue correlations for sequential assignment of membrane proteins. DAISY can be implemented in 3D experiments that include the polarization inversion spin exchange at magic angle via I spin coherence (PISEMAI) sequence, as we show for the simultaneous acquisition of 3D PISEMAI-HETCOR and 3D PISEMAI-HETCOR-mixing experiments.

  20. Simultaneous acquisition of 2D and 3D solid-state NMR experiments for sequential assignment of oriented membrane protein samples

    International Nuclear Information System (INIS)

    Gopinath, T.; Mote, Kaustubh R.; Veglia, Gianluigi

    2015-01-01

    We present a new method called DAISY (Dual Acquisition orIented ssNMR spectroScopY) for the simultaneous acquisition of 2D and 3D oriented solid-state NMR experiments for membrane proteins reconstituted in mechanically or magnetically aligned lipid bilayers. DAISY utilizes dual acquisition of sine and cosine dipolar or chemical shift coherences and long living 15 N longitudinal polarization to obtain two multi-dimensional spectra, simultaneously. In these new experiments, the first acquisition gives the polarization inversion spin exchange at the magic angle (PISEMA) or heteronuclear correlation (HETCOR) spectra, the second acquisition gives PISEMA-mixing or HETCOR-mixing spectra, where the mixing element enables inter-residue correlations through 15 N– 15 N homonuclear polarization transfer. The analysis of the two 2D spectra (first and second acquisitions) enables one to distinguish 15 N– 15 N inter-residue correlations for sequential assignment of membrane proteins. DAISY can be implemented in 3D experiments that include the polarization inversion spin exchange at magic angle via I spin coherence (PISEMAI) sequence, as we show for the simultaneous acquisition of 3D PISEMAI–HETCOR and 3D PISEMAI–HETCOR-mixing experiments

  1. Location Prediction Based on Transition Probability Matrices Constructing from Sequential Rules for Spatial-Temporal K-Anonymity Dataset

    Science.gov (United States)

    Liu, Zhao; Zhu, Yunhong; Wu, Chenxue

    2016-01-01

    Spatial-temporal k-anonymity has become a mainstream approach among techniques for protection of users’ privacy in location-based services (LBS) applications, and has been applied to several variants such as LBS snapshot queries and continuous queries. Analyzing large-scale spatial-temporal anonymity sets may benefit several LBS applications. In this paper, we propose two location prediction methods based on transition probability matrices constructing from sequential rules for spatial-temporal k-anonymity dataset. First, we define single-step sequential rules mined from sequential spatial-temporal k-anonymity datasets generated from continuous LBS queries for multiple users. We then construct transition probability matrices from mined single-step sequential rules, and normalize the transition probabilities in the transition matrices. Next, we regard a mobility model for an LBS requester as a stationary stochastic process and compute the n-step transition probability matrices by raising the normalized transition probability matrices to the power n. Furthermore, we propose two location prediction methods: rough prediction and accurate prediction. The former achieves the probabilities of arriving at target locations along simple paths those include only current locations, target locations and transition steps. By iteratively combining the probabilities for simple paths with n steps and the probabilities for detailed paths with n-1 steps, the latter method calculates transition probabilities for detailed paths with n steps from current locations to target locations. Finally, we conduct extensive experiments, and correctness and flexibility of our proposed algorithm have been verified. PMID:27508502

  2. Modular Principles for Flexibility of Spaces in Skill Acquisition ...

    African Journals Online (AJOL)

    The design of skill centre around the country is such that they are specific to particular skill type and usually the buildings cannot be used for another activity. The need to use spaces for multiple functions has ensured that flexible spaces in skill acquisition centres are designed such that the spaces can easily be varied into ...

  3. 26 CFR 1.401(k)-5 - Special rules for mergers, acquisitions and similar events. [Reserved

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Special rules for mergers, acquisitions and similar events. [Reserved] 1.401(k)-5 Section 1.401(k)-5 Internal Revenue INTERNAL REVENUE SERVICE... Bonus Plans, Etc. § 1.401(k)-5 Special rules for mergers, acquisitions and similar events. [Reserved] [T...

  4. Sodium magnetic resonance imaging. Development of a 3D radial acquisition technique with optimized k-space sampling density and high SNR-efficiency

    International Nuclear Information System (INIS)

    Nagel, Armin Michael

    2009-01-01

    A 3D radial k-space acquisition technique with homogenous distribution of the sampling density (DA-3D-RAD) is presented. This technique enables short echo times (TE 23 Na-MRI, and provides a high SNR-efficiency. The gradients of the DA-3D-RAD-sequence are designed such that the average sampling density in each spherical shell of k-space is constant. The DA-3D-RAD-sequence provides 34% more SNR than a conventional 3D radial sequence (3D-RAD) if T 2 * -decay is neglected. This SNR-gain is enhanced if T 2 * -decay is present, so a 1.5 to 1.8 fold higher SNR is measured in brain tissue with the DA-3D-RAD-sequence. Simulations and experimental measurements show that the DA-3D-RAD sequence yields a better resolution in the presence of T 2 * -decay and less image artefacts when B 0 -inhomogeneities exist. Using the developed sequence, T 1 -, T 2 * - and Inversion-Recovery- 23 Na-image contrasts were acquired for several organs and 23 Na-relaxation times were measured (brain tissue: T 1 =29.0±0.3 ms; T 2s * ∼4 ms; T 2l * ∼31 ms; cerebrospinal fluid: T 1 =58.1±0.6 ms; T 2 * =55±3 ms (B 0 =3 T)). T 1 - und T 2 * -relaxation times of cerebrospinal fluid are independent of the selected magnetic field strength (B0 = 3T/7 T), whereas the relaxation times of brain tissue increase with field strength. Furthermore, 23 Na-signals of oedemata were suppressed in patients and thus signals from different tissue compartments were selectively measured. (orig.)

  5. A higher level language data acquisition system (III) - the user data acquisition program

    International Nuclear Information System (INIS)

    Finn, J.M.; Gulbranson, R.L.; Huang, T.L.

    1983-01-01

    The nuclear physics group at the University of Illinois has implemented a data acquisition system using modified versions of the Concurrent Pascal and Sequential Pascal languages. The user, a physicist, develops a data acquisition ''operating system'', written in these higher level languages, which is tailored to the planned experiment. The user must include only those system functions which are essential to the task, thus improving efficiency. The user program is constructed from simple modules, mainly consisting of Concurrent Pascal PROCESSes, MONITORs, and CLASSes together with appropriate data type definitions. Entire programs can be put together using ''cut and paste'' techniques. Planned enhancements include the automating of this process. Systems written for the Perkin-Elmer 3220 using this approach can easily exceed 2 kHz data rates for event by event handling; 20 kHz data rates have been achieved by the addition of buffers in the interrupt handling software. These rates have been achieved without the use of special-purpose hardware such as micro-programmed branch drivers. With the addition of such devices even higher data rates should be possible

  6. Vocal sequential exchanges and intragroup spacing in the Northern Muriqui Brachyteles arachnoides hypoxanthus.

    Science.gov (United States)

    Mendes, Francisco D C; Ades, César

    2004-06-01

    Sequential exchanges of vocalizations (staccatos and neighs) emitted by Northern Muriquis Brachyteles arachnoides hypoxanthus were recorded at the Biological Station of Caratinga, Minas Gerais State, Brazil. Staccatos and neighs containing larger proportion of short elements were preferentially produced during short-range exchanges; neighs, produced by a larger number of participants, were typical of long-range exchanges. Staccatos emitted by animals feeding in a dispersed manner contained a larger proportion of tonal elements than those emitted by muriquis feeding in a cohesive manner. Sequential exchanges seem thus to be constituted by two inter-related subsystems of calls that aid muriquis to coordinate intragroup spacing, despite the poor visibility of the habitat.

  7. Value-informed space systems design and acquisition

    Science.gov (United States)

    Brathwaite, Joy

    Investments in space systems are substantial, indivisible, and irreversible, characteristics that make them high-risk, especially when coupled with an uncertain demand environment. Traditional approaches to system design and acquisition, derived from a performance- or cost-centric mindset, incorporate little information about the spacecraft in relation to its environment and its value to its stakeholders. These traditional approaches, while appropriate in stable environments, are ill-suited for the current, distinctly uncertain, and rapidly changing technical and economic conditions; as such, they have to be revisited and adapted to the present context. This thesis proposes that in uncertain environments, decision-making with respect to space system design and acquisition should be value-based, or at a minimum value-informed. This research advances the value-centric paradigm by providing the theoretical basis, foundational frameworks, and supporting analytical tools for value assessment of priced and unpriced space systems. For priced systems, stochastic models of the market environment and financial models of stakeholder preferences are developed and integrated with a spacecraft-sizing tool to assess the system's net present value. The analytical framework is applied to a case study of a communications satellite, with market, financial, and technical data obtained from the satellite operator, Intelsat. The case study investigates the implications of the value-centric versus the cost-centric design and acquisition choices. Results identify the ways in which value-optimal spacecraft design choices are contingent on both technical and market conditions, and that larger spacecraft for example, which reap economies of scale benefits, as reflected by their decreasing cost-per-transponder, are not always the best (most valuable) choices. Market conditions and technical constraints for which convergence occurs between design choices under a cost-centric and a value

  8. Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI.

    Science.gov (United States)

    Gai, Neville D; Malayeri, Ashkan A; Bluemke, David A

    2017-08-01

    Long T2 species can interfere with visualization of short T2 tissue imaging. For example, visualization of lung parenchyma can be hindered by breathing artifacts primarily from fat in the chest wall. The purpose of this work was to design and evaluate a scheme for long T2 species suppression in lung parenchyma imaging using 3-D inversion recovery double-echo ultrashort echo time imaging with a k-space reordering scheme for artifact suppression. A hyperbolic secant (HS) pulse was evaluated for different tissues (T1/T2). Bloch simulations were performed with the inversion pulse followed by segmented UTE acquisition. Point spread function (PSF) was simulated for a standard interleaved acquisition order and a modulo 2 forward-reverse acquisition order. Phantom and in vivo images (eight volunteers) were acquired with both acquisition orders. Contrast to noise ratio (CNR) was evaluated in in vivo images prior to and after introduction of the long T2 suppression scheme. The PSF as well as phantom and in vivo images demonstrated reduction in artifacts arising from k-space modulation after using the reordering scheme. CNR measured between lung and fat and lung and muscle increased from -114 and -148.5 to +12.5 and 2.8 after use of the IR-DUTE sequence. Paired t test between the CNRs obtained from UTE and IR-DUTE showed significant positive change (p lung-fat CNR and p = 0.03 for lung-muscle CNR). Full 3-D lung parenchyma imaging with improved positive contrast between lung and other long T2 tissue types can be achieved robustly in a clinically feasible time using IR-DUTE with image subtraction when segmented radial acquisition with k-space reordering is employed.

  9. Vocal sequential exchanges and intragroup spacing in the Northern Muriqui Brachyteles arachnoides hypoxanthus

    Directory of Open Access Journals (Sweden)

    Mendes Francisco D.C.

    2004-01-01

    Full Text Available Sequential exchanges of vocalizations (staccatos and neighs emitted by Northern Muriquis Brachyteles arachnoides hypoxanthus were recorded at the Biological Station of Caratinga, Minas Gerais State, Brazil. Staccatos and neighs containing larger proportion of short elements were preferentially produced during short-range exchanges; neighs, produced by a larger number of participants, were typical of long-range exchanges. Staccatos emitted by animals feeding in a dispersed manner contained a larger proportion of tonal elements than those emitted by muriquis feeding in a cohesive manner. Sequential exchanges seem thus to be constituted by two inter-related subsystems of calls that aid muriquis to coordinate intragroup spacing, despite the poor visibility of the habitat.

  10. Leveraging EAP-Sparsity for Compressed Sensing of MS-HARDI in (k, q)-Space.

    Science.gov (United States)

    Sun, Jiaqi; Sakhaee, Elham; Entezari, Alireza; Vemuri, Baba C

    2015-01-01

    Compressed Sensing (CS) for the acceleration of MR scans has been widely investigated in the past decade. Lately, considerable progress has been made in achieving similar speed ups in acquiring multi-shell high angular resolution diffusion imaging (MS-HARDI) scans. Existing approaches in this context were primarily concerned with sparse reconstruction of the diffusion MR signal S(q) in the q-space. More recently, methods have been developed to apply the compressed sensing framework to the 6-dimensional joint (k, q)-space, thereby exploiting the redundancy in this 6D space. To guarantee accurate reconstruction from partial MS-HARDI data, the key ingredients of compressed sensing that need to be brought together are: (1) the function to be reconstructed needs to have a sparse representation, and (2) the data for reconstruction ought to be acquired in the dual domain (i.e., incoherent sensing) and (3) the reconstruction process involves a (convex) optimization. In this paper, we present a novel approach that uses partial Fourier sensing in the 6D space of (k, q) for the reconstruction of P(x, r). The distinct feature of our approach is a sparsity model that leverages surfacelets in conjunction with total variation for the joint sparse representation of P(x, r). Thus, our method stands to benefit from the practical guarantees for accurate reconstruction from partial (k, q)-space data. Further, we demonstrate significant savings in acquisition time over diffusion spectral imaging (DSI) which is commonly used as the benchmark for comparisons in reported literature. To demonstrate the benefits of this approach,.we present several synthetic and real data examples.

  11. 41 CFR 102-73.155 - What types of space can Federal agencies acquire with a categorical space delegation?

    Science.gov (United States)

    2010-07-01

    ... MANAGEMENT REGULATION REAL PROPERTY 73-REAL ESTATE ACQUISITION Acquisition by Lease Categorical Space... temporary duty travel or employee relocation); (j) Laundries; (k) Quarantine facilities for plants, birds...

  12. Post-Acquisition IT Integration

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Yetton, Philip

    2013-01-01

    The extant research on post-acquisition IT integration analyzes how acquirers realize IT-based value in individual acquisitions. However, serial acquirers make 60% of acquisitions. These acquisitions are not isolated events, but are components in growth-by-acquisition programs. To explain how...... serial acquirers realize IT-based value, we develop three propositions on the sequential effects on post-acquisition IT integration in acquisition programs. Their combined explanation is that serial acquirers must have a growth-by-acquisition strategy that includes the capability to improve...... IT integration capabilities, to sustain high alignment across acquisitions and to maintain a scalable IT infrastructure with a flat or decreasing cost structure. We begin the process of validating the three propositions by investigating a longitudinal case study of a growth-by-acquisition program....

  13. Self-gated 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) using rotating cartesian K-space (ROCK): Validation in children with congenital heart disease.

    Science.gov (United States)

    Han, Fei; Zhou, Ziwu; Han, Eric; Gao, Yu; Nguyen, Kim-Lien; Finn, J Paul; Hu, Peng

    2017-08-01

    To develop and validate a cardiac-respiratory self-gating strategy for the recently proposed multiphase steady-state imaging with contrast enhancement (MUSIC) technique. The proposed SG strategy uses the ROtating Cartesian K-space (ROCK) sampling, which allows for retrospective k-space binning based on motion surrogates derived from k-space center line. The k-space bins are reconstructed using a compressed sensing algorithm. Ten pediatric patients underwent cardiac MRI for clinical reasons. The original MUSIC and 2D-CINE images were acquired as a part of the clinical protocol, followed by the ROCK-MUSIC acquisition, all under steady-state intravascular distribution of ferumoxytol. Subjective scores and image sharpness were used to compare the images of ROCK-MUSIC and original MUSIC. All scans were completed successfully without complications. The ROCK-MUSIC acquisition took 5 ± 1 min, compared to 8 ± 2 min for the original MUSIC. Image scores of ROCK-MUSIC were significantly better than original MUSIC at the ventricular outflow tracts (3.9 ± 0.3 vs. 3.3 ± 0.6, P ROCK-MUSIC in the other anatomic locations. ROCK-MUSIC provided images of equal or superior image quality compared to original MUSIC, and this was achievable with 40% savings in scan time and without the need for physiologic signal. Magn Reson Med 78:472-483, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Towards a computational spatial knowledge acquisition model in architectural space

    NARCIS (Netherlands)

    Lyu, J.; Vries, de B.; Sun, C.; Sun, C.; Zhang, J.

    2013-01-01

    Abstract. Existing research which is related to spatial knowledge acquisition often shows a limited scope because of the complexity in the cognition process. Research in spatial representation such as space syntax presumes that vision drives movement. This assumption is only true under certain

  15. IT-based Value Creation in Serial Acquisitions

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Yetton, Philip

    2013-01-01

    serial acquirers realize IT-based value, we integrate and model the findings on individual acquisitions from the extant literature, and extend that model to explain the effects of sequential acquisitions in a growth-by-acquisition strategy. This extended model, drawing on the Resource-Based Theory......The extant research on post-acquisition IT integration analyzes how acquirers realize IT-based value in individual acquisitions. However, serial acquirers make 60% of acquisitions. These acquisitions are not isolated events, but are components in growth-by-acquisition programs. To explain how...

  16. Acquisition of Inductive Biconditional Reasoning Skills: Training of Simultaneous and Sequential Processing.

    Science.gov (United States)

    Lee, Seong-Soo

    1982-01-01

    Tenth-grade students (n=144) received training on one of three processing methods: coding-mapping (simultaneous), coding only, or decision tree (sequential). The induced simultaneous processing strategy worked optimally under rule learning, while the sequential strategy was difficult to induce and/or not optimal for rule-learning operations.…

  17. Encoding Sequential Information in Semantic Space Models: Comparing Holographic Reduced Representation and Random Permutation

    Directory of Open Access Journals (Sweden)

    Gabriel Recchia

    2015-01-01

    Full Text Available Circular convolution and random permutation have each been proposed as neurally plausible binding operators capable of encoding sequential information in semantic memory. We perform several controlled comparisons of circular convolution and random permutation as means of encoding paired associates as well as encoding sequential information. Random permutations outperformed convolution with respect to the number of paired associates that can be reliably stored in a single memory trace. Performance was equal on semantic tasks when using a small corpus, but random permutations were ultimately capable of achieving superior performance due to their higher scalability to large corpora. Finally, “noisy” permutations in which units are mapped to other units arbitrarily (no one-to-one mapping perform nearly as well as true permutations. These findings increase the neurological plausibility of random permutations and highlight their utility in vector space models of semantics.

  18. Variation among heritage speakers: Sequential vs. simultaneous bilinguals

    Directory of Open Access Journals (Sweden)

    Teresa Lee

    2013-08-01

    Full Text Available This study examines the differences in the grammatical knowledge of two types of heritage speakers of Korean. Early simultaneous bilinguals are exposed to both English and the heritage language from birth, whereas early sequential bilinguals are exposed to the heritage language first and then to English upon schooling. A listening comprehension task involving relative clauses was conducted with 51 beginning-level Korean heritage speakers. The results showed that the early sequential bilinguals exhibited much more accurate knowledge than the early simultaneous bilinguals, who lacked rudimentary knowledge of Korean relative clauses. Drawing on the findings of adult and child Korean L1 data on the acquisition of relative clauses, the performance of each group is discussed with respect to attrition and incomplete acquisition of the heritage language.

  19. Use of the K-ABC with Children in Zaire, Africa: An Evaluation of the Sequential-Simultaneous Processing Distinction within an Intercultural Context.

    Science.gov (United States)

    Giordani, Bruno; And Others

    1996-01-01

    Evaluation of the Kaufman Assessment Battery for Children (K-ABC) with 130 primary school children in Zaire revealed three findings: (1) the distinction between sequential processing and simultaneous processing was valid; (2) the K-ABC discriminated effectively among grade levels, health and family environment variables, and tribal membership; and…

  20. The Spacing Effect and Its Relevance to Second Language Acquisition

    Science.gov (United States)

    Rogers, John

    2017-01-01

    This commentary discusses some theoretical and methodological issues related to research on the spacing effect in second language acquisition research (SLA). There has been a growing interest in SLA in how the temporal distribution of input might impact language development. SLA research in this area has frequently drawn upon the rich field of…

  1. Wald Sequential Probability Ratio Test for Space Object Conjunction Assessment

    Science.gov (United States)

    Carpenter, James R.; Markley, F Landis

    2014-01-01

    This paper shows how satellite owner/operators may use sequential estimates of collision probability, along with a prior assessment of the base risk of collision, in a compound hypothesis ratio test to inform decisions concerning collision risk mitigation maneuvers. The compound hypothesis test reduces to a simple probability ratio test, which appears to be a novel result. The test satisfies tolerances related to targeted false alarm and missed detection rates. This result is independent of the method one uses to compute the probability density that one integrates to compute collision probability. A well-established test case from the literature shows that this test yields acceptable results within the constraints of a typical operational conjunction assessment decision timeline. Another example illustrates the use of the test in a practical conjunction assessment scenario based on operations of the International Space Station.

  2. War-gaming application for future space systems acquisition part 2: acquisition and bidding war-gaming modeling and simulation approaches for FFP and FPIF

    Science.gov (United States)

    Nguyen, Tien M.; Guillen, Andy T.

    2017-05-01

    This paper describes cooperative and non-cooperative static Bayesian game models with complete and incomplete information for the development of optimum acquisition strategies associated with the Program and Technical Baseline (PTB) solutions obtained from Part 1 of this paper [1]. The optimum acquisition strategies discussed focus on achieving "Affordability" by incorporating contractors' bidding strategies into the government acquisition strategies for acquiring future space systems. The paper discusses System Engineering (SE) frameworks, analytical and simulation approaches and modeling for developing the optimum acquisition strategies from both the government and contractor perspectives for Firm Fixed Price (FFP) and Fixed Price Incentive Firm (FPIF) contract types.

  3. Characterizing sequential isomorphisms on Hilbert-space effect algebras

    International Nuclear Information System (INIS)

    Hou Jinchuan; He Kan; Qi Xiaofei

    2010-01-01

    Let * be any sequential product on the Hilbert-space effect algebra E(H) with dim H≥2, and Φ:E(H)→E(H) be a bijective map. We show that if Φ satisfies Φ(A*B) = Φ(A)*Φ(B) for A,B element of E(H), then there is either a unitary or an anti-unitary operator U such that Φ(A) = UAU† for every A element of E(H). Let g:[0,1]→{λ|λ element of C, |λ|=0 or 1} be a Borel function satisfying g(0) = 0, g(1) = 1 and let us define a binary operation lozenge g on E(H) by A lozenge g B = A 1/2 g(A)Bg(A)†A 1/2 , where T† denotes the conjugate of the operator T. We also show that a bijective map Φ:E(H)→E(H) satisfies Φ(A lozenge g B) = Φ(A) lozenge g Φ(B) for A,B element of E(H) if and only if there is either a unitary or an anti-unitary operator U such that Φ(A) = UAU† for every A element of E(H).

  4. Dynamic Space - uus köögistandard

    Index Scriptorium Estoniae

    2005-01-01

    Furnituuritootja Blum'i - ainuesindaja Eestis Hahle Eesti OÜ - poolt välja töötatud köögistandardi Dynamic Space põhimõtetest (piisav kasulik paigutusruum, viis köögitsooni, alumiste kappide asemel lõpuni lahtitõmmatavate ORGA-LINE sisejaotustega sahtlite eelistamine)

  5. SU-F-J-158: Respiratory Motion Resolved, Self-Gated 4D-MRI Using Rotating Cartesian K-Space Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Han, F; Zhou, Z; Yang, Y; Sheng, K; Hu, P [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: Dynamic MRI has been used to quantify respiratory motion of abdominal organs in radiation treatment planning. Many existing 4D-MRI methods based on 2D acquisitions suffer from limited slice resolution and additional stitching artifacts when evaluated in 3D{sup 1}. To address these issues, we developed a 4D-MRI (3D dynamic) technique with true 3D k-space encoding and respiratory motion self-gating. Methods: The 3D k-space was acquired using a Rotating Cartesian K-space (ROCK) pattern, where the Cartesian grid was reordered in a quasi-spiral fashion with each spiral arm rotated using golden angle{sup 2}. Each quasi-spiral arm started with the k-space center-line, which were used as self-gating{sup 3} signal for respiratory motion estimation. The acquired k-space data was then binned into 8 respiratory phases and the golden angle ensures a near-uniform k-space sampling in each phase. Finally, dynamic 3D images were reconstructed using the ESPIRiT technique{sup 4}. 4D-MRI was performed on 6 healthy volunteers, using the following parameters (bSSFP, Fat-Sat, TE/TR=2ms/4ms, matrix size=500×350×120, resolution=1×1×1.2mm, TA=5min, 8 respiratory phases). Supplemental 2D real-time images were acquired in 9 different planes. Dynamic locations of the diaphragm dome and left kidney were measured from both 4D and 2D images. The same protocol was also performed on a MRI-compatible motion phantom where the motion was programmed with different amplitude (10–30mm) and frequency (3–10/min). Results: High resolution 4D-MRI were obtained successfully in 5 minutes. Quantitative motion measurements from 4D-MRI agree with the ones from 2D CINE (<5% error). The 4D images are free of the stitching artifacts and their near-isotropic resolution facilitates 3D visualization and segmentation of abdominal organs such as the liver, kidney and pancreas. Conclusion: Our preliminary studies demonstrated a novel ROCK 4D-MRI technique with true 3D k-space encoding and respiratory

  6. Comparison of continuous with step and shoot acquisition in SPECT scanning

    International Nuclear Information System (INIS)

    McCarthy, L.; Cotterill, T.; Chu, J.M.G.

    1998-01-01

    Full text: Following the recent advent of continuous acquisition for performing SPECT scanning, it was decided to compare the commonly used Step and Shoot mode of acquisition with the new continuous acquisition mode. The aim of the study is to assess any difference in resolution from the resulting images acquired using the two modes of acquisition. Sequential series of studies were performed on a SPECT phantom using both modes of acquisition. Separate sets of data were collected for both high resolution parallel hole and ultra high resolution fan beam collimators. Clinical data was collected on patients undergoing routine gallium, 99m Tc-MDP bone and 99m Tc-HMPAO brain studies. Separate sequential acquisition in both modes were collected for each patient. The sequence of collection was also alternated. Reconstruction was performed utilising the same parameters for each acquisition. The reconstructed data were assessed visually by blinded observers to detect differences in resolution and image quality. No significant difference in the studies collected by either acquisition modes were detected. The time saved by continuous acquisition could be an advantage

  7. The scientific data acquisition system of the GAMMA-400 space project

    Science.gov (United States)

    Bobkov, S. G.; Serdin, O. V.; Gorbunov, M. S.; Arkhangelskiy, A. I.; Topchiev, N. P.

    2016-02-01

    The description of scientific data acquisition system (SDAS) designed by SRISA for the GAMMA-400 space project is presented. We consider the problem of different level electronics unification: the set of reliable fault-tolerant integrated circuits fabricated on Silicon-on-Insulator 0.25 mkm CMOS technology and the high-speed interfaces and reliable modules used in the space instruments. The characteristics of reliable fault-tolerant very large scale integration (VLSI) technology designed by SRISA for the developing of computation systems for space applications are considered. The scalable net structure of SDAS based on Serial RapidIO interface including real-time operating system BAGET is described too.

  8. On spaces Cb(X) weakly K-analytic

    Czech Academy of Sciences Publication Activity Database

    Ferrando, J.C.; Kąkol, Jerzy; López-Pellicer, M.

    2017-01-01

    Roč. 290, č. 16 (2017), s. 2612-2618 ISSN 0025-584X R&D Projects: GA ČR GF16-34860L Institutional support: RVO:67985840 Keywords : K-analytic space * pseudocompact space * rainwater set Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.742, year: 2016

  9. Spacing Techniques in Second Language Vocabulary Acquisition: Short-Term Gains vs. Long-Term Memory

    Science.gov (United States)

    Schuetze, Ulf

    2015-01-01

    This article reports the results of two experiments using the spacing technique (Leitner, 1972; Landauer & Bjork, 1978) in second language vocabulary acquisition. In the past, studies in this area have produced mixed results attempting to differentiate between massed, uniform and expanded intervals of spacing (Balota, Duchek, & Logan,…

  10. Data Acquisition System

    International Nuclear Information System (INIS)

    Cirstea, C.D.; Buda, S.I.; Constantin, F.

    2005-01-01

    This paper deals with a multi parametric acquisition system developed for a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)

  11. Data acquisition system

    International Nuclear Information System (INIS)

    Cirstea, D.C.; Buda, S.I.; Constantin, F.

    2005-01-01

    The topic of this paper deals with a multi parametric acquisition system developed around a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming, the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)

  12. A radial sampling strategy for uniform k-space coverage with retrospective respiratory gating in 3D ultrashort-echo-time lung imaging.

    Science.gov (United States)

    Park, Jinil; Shin, Taehoon; Yoon, Soon Ho; Goo, Jin Mo; Park, Jang-Yeon

    2016-05-01

    The purpose of this work was to develop a 3D radial-sampling strategy which maintains uniform k-space sample density after retrospective respiratory gating, and demonstrate its feasibility in free-breathing ultrashort-echo-time lung MRI. A multi-shot, interleaved 3D radial sampling function was designed by segmenting a single-shot trajectory of projection views such that each interleaf samples k-space in an incoherent fashion. An optimal segmentation factor for the interleaved acquisition was derived based on an approximate model of respiratory patterns such that radial interleaves are evenly accepted during the retrospective gating. The optimality of the proposed sampling scheme was tested by numerical simulations and phantom experiments using human respiratory waveforms. Retrospectively, respiratory-gated, free-breathing lung MRI with the proposed sampling strategy was performed in healthy subjects. The simulation yielded the most uniform k-space sample density with the optimal segmentation factor, as evidenced by the smallest standard deviation of the number of neighboring samples as well as minimal side-lobe energy in the point spread function. The optimality of the proposed scheme was also confirmed by minimal image artifacts in phantom images. Human lung images showed that the proposed sampling scheme significantly reduced streak and ring artifacts compared with the conventional retrospective respiratory gating while suppressing motion-related blurring compared with full sampling without respiratory gating. In conclusion, the proposed 3D radial-sampling scheme can effectively suppress the image artifacts due to non-uniform k-space sample density in retrospectively respiratory-gated lung MRI by uniformly distributing gated radial views across the k-space. Copyright © 2016 John Wiley & Sons, Ltd.

  13. The extension of quadrupled xed point results in K-metric spaces

    Directory of Open Access Journals (Sweden)

    Ghasem Soleimani Rad

    2014-05-01

    Full Text Available Recently, Rahimi et al. [Comp. Appl. Math. 2013, In press] dened the conceptof quadrupled xed point in K-metric spaces and proved several quadrupled  xed point theorems for solid cones on K-metric spaces. In this paper some quadrupled xed point results for T-contraction on K-metric spaces without normality condition are proved. Obtained results extend and generalize well-known comparable results in the literature.

  14. Reduced aliasing artifacts using shaking projection k-space sampling trajectory

    Science.gov (United States)

    Zhu, Yan-Chun; Du, Jiang; Yang, Wen-Chao; Duan, Chai-Jie; Wang, Hao-Yu; Gao, Song; Bao, Shang-Lian

    2014-03-01

    Radial imaging techniques, such as projection-reconstruction (PR), are used in magnetic resonance imaging (MRI) for dynamic imaging, angiography, and short-T2 imaging. They are less sensitive to flow and motion artifacts, and support fast imaging with short echo times. However, aliasing and streaking artifacts are two main sources which degrade radial imaging quality. For a given fixed number of k-space projections, data distributions along radial and angular directions will influence the level of aliasing and streaking artifacts. Conventional radial k-space sampling trajectory introduces an aliasing artifact at the first principal ring of point spread function (PSF). In this paper, a shaking projection (SP) k-space sampling trajectory was proposed to reduce aliasing artifacts in MR images. SP sampling trajectory shifts the projection alternately along the k-space center, which separates k-space data in the azimuthal direction. Simulations based on conventional and SP sampling trajectories were compared with the same number projections. A significant reduction of aliasing artifacts was observed using the SP sampling trajectory. These two trajectories were also compared with different sampling frequencies. A SP trajectory has the same aliasing character when using half sampling frequency (or half data) for reconstruction. SNR comparisons with different white noise levels show that these two trajectories have the same SNR character. In conclusion, the SP trajectory can reduce the aliasing artifact without decreasing SNR and also provide a way for undersampling reconstruction. Furthermore, this method can be applied to three-dimensional (3D) hybrid or spherical radial k-space sampling for a more efficient reduction of aliasing artifacts.

  15. Reduced aliasing artifacts using shaking projection k-space sampling trajectory

    International Nuclear Information System (INIS)

    Zhu Yan-Chun; Yang Wen-Chao; Wang Hao-Yu; Gao Song; Bao Shang-Lian; Du Jiang; Duan Chai-Jie

    2014-01-01

    Radial imaging techniques, such as projection-reconstruction (PR), are used in magnetic resonance imaging (MRI) for dynamic imaging, angiography, and short-T2 imaging. They are less sensitive to flow and motion artifacts, and support fast imaging with short echo times. However, aliasing and streaking artifacts are two main sources which degrade radial imaging quality. For a given fixed number of k-space projections, data distributions along radial and angular directions will influence the level of aliasing and streaking artifacts. Conventional radial k-space sampling trajectory introduces an aliasing artifact at the first principal ring of point spread function (PSF). In this paper, a shaking projection (SP) k-space sampling trajectory was proposed to reduce aliasing artifacts in MR images. SP sampling trajectory shifts the projection alternately along the k-space center, which separates k-space data in the azimuthal direction. Simulations based on conventional and SP sampling trajectories were compared with the same number projections. A significant reduction of aliasing artifacts was observed using the SP sampling trajectory. These two trajectories were also compared with different sampling frequencies. A SP trajectory has the same aliasing character when using half sampling frequency (or half data) for reconstruction. SNR comparisons with different white noise levels show that these two trajectories have the same SNR character. In conclusion, the SP trajectory can reduce the aliasing artifact without decreasing SNR and also provide a way for undersampling reconstruction. Furthermore, this method can be applied to three-dimensional (3D) hybrid or spherical radial k-space sampling for a more efficient reduction of aliasing artifacts

  16. 76 FR 36951 - In the Matter of Shiming U.S., Inc., Si Mei Te Food Ltd. (f/k/a China Discovery Acquisition Corp...

    Science.gov (United States)

    2011-06-23

    ... Food Ltd. (f/k/a China Discovery Acquisition Corp.), Sierra International Group, Inc., and SJ... concerning the securities of Si Mei Te Food Ltd. (f/k/a China Discovery Acquisition Corp.) because it has not.... Therefore, it is ordered, pursuant to Section 12(k) of the Securities Exchange Act of 1934, that trading in...

  17. Do material, psychosocial and behavioural factors mediate the relationship between disability acquisition and mental health? A sequential causal mediation analysis.

    Science.gov (United States)

    Aitken, Zoe; Simpson, Julie Anne; Gurrin, Lyle; Bentley, Rebecca; Kavanagh, Anne Marie

    2018-01-29

    There is evidence of a causal relationship between disability acquisition and poor mental health; however, the mechanism by which disability affects mental health is poorly understood. This gap in understanding limits the development of effective interventions to improve the mental health of people with disabilities. We used four waves of data from the Household, Income and Labour Dynamics in Australia Survey (2011-14) to compare self-reported mental health between individuals who acquired any disability (n=387) and those who remained disability-free (n=7936). We tested three possible pathways from disability acquisition to mental health, examining the effect of material, psychosocial and behavioural mediators. The effect was partitioned into natural direct and indirect effects through the mediators using a sequential causal mediation analysis approach. Multiple imputation using chained equations was used to assess the impact of missing data. Disability acquisition was estimated to cause a five-point decline in mental health [estimated mean difference: -5.3, 95% confidence interval (CI) -6.8, -3.7]. The indirect effect through material factors was estimated to be a 1.7-point difference (-1.7, 95% CI -2.8, -0.6), explaining 32% of the total effect, with a negligible proportion of the effect explained by the addition of psychosocial characteristics (material and psychosocial: -1.7, 95% CI -3.0, -0.5) and a further 5% by behavioural factors (material-psychosocial-behavioural: -2.0, 95% CI -3.4, -0.6). The finding that the effect of disability acquisition on mental health operates predominantly through material rather than psychosocial and behavioural factors has important implications. The results highlight the need for better social protection, including income support, employment and education opportunities, and affordable housing for people who acquire a disability. © The Author(s) 2018; all rights reserved. Published by Oxford University Press on behalf of the

  18. Heat accumulation during sequential cortical bone drilling.

    Science.gov (United States)

    Palmisano, Andrew C; Tai, Bruce L; Belmont, Barry; Irwin, Todd A; Shih, Albert; Holmes, James R

    2016-03-01

    Significant research exists regarding heat production during single-hole bone drilling. No published data exist regarding repetitive sequential drilling. This study elucidates the phenomenon of heat accumulation for sequential drilling with both Kirschner wires (K wires) and standard two-flute twist drills. It was hypothesized that cumulative heat would result in a higher temperature with each subsequent drill pass. Nine holes in a 3 × 3 array were drilled sequentially on moistened cadaveric tibia bone kept at body temperature (about 37 °C). Four thermocouples were placed at the center of four adjacent holes and 2 mm below the surface. A battery-driven hand drill guided by a servo-controlled motion system was used. Six samples were drilled with each tool (2.0 mm K wire and 2.0 and 2.5 mm standard drills). K wire drilling increased temperature from 5 °C at the first hole to 20 °C at holes 6 through 9. A similar trend was found in standard drills with less significant increments. The maximum temperatures of both tools increased from drill sizes was found to be insignificant (P > 0.05). In conclusion, heat accumulated during sequential drilling, with size difference being insignificant. K wire produced more heat than its twist-drill counterparts. This study has demonstrated the heat accumulation phenomenon and its significant effect on temperature. Maximizing the drilling field and reducing the number of drill passes may decrease bone injury. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  19. Learning of state-space models with highly informative observations: A tempered sequential Monte Carlo solution

    Science.gov (United States)

    Svensson, Andreas; Schön, Thomas B.; Lindsten, Fredrik

    2018-05-01

    Probabilistic (or Bayesian) modeling and learning offers interesting possibilities for systematic representation of uncertainty using probability theory. However, probabilistic learning often leads to computationally challenging problems. Some problems of this type that were previously intractable can now be solved on standard personal computers thanks to recent advances in Monte Carlo methods. In particular, for learning of unknown parameters in nonlinear state-space models, methods based on the particle filter (a Monte Carlo method) have proven very useful. A notoriously challenging problem, however, still occurs when the observations in the state-space model are highly informative, i.e. when there is very little or no measurement noise present, relative to the amount of process noise. The particle filter will then struggle in estimating one of the basic components for probabilistic learning, namely the likelihood p (data | parameters). To this end we suggest an algorithm which initially assumes that there is substantial amount of artificial measurement noise present. The variance of this noise is sequentially decreased in an adaptive fashion such that we, in the end, recover the original problem or possibly a very close approximation of it. The main component in our algorithm is a sequential Monte Carlo (SMC) sampler, which gives our proposed method a clear resemblance to the SMC2 method. Another natural link is also made to the ideas underlying the approximate Bayesian computation (ABC). We illustrate it with numerical examples, and in particular show promising results for a challenging Wiener-Hammerstein benchmark problem.

  20. Modeling Search Behaviors during the Acquisition of Expertise in a Sequential Decision-Making Task

    Directory of Open Access Journals (Sweden)

    Cristóbal Moënne-Loccoz

    2017-09-01

    Full Text Available Our daily interaction with the world is plagued of situations in which we develop expertise through self-motivated repetition of the same task. In many of these interactions, and especially when dealing with computer and machine interfaces, we must deal with sequences of decisions and actions. For instance, when drawing cash from an ATM machine, choices are presented in a step-by-step fashion and a specific sequence of choices must be performed in order to produce the expected outcome. But, as we become experts in the use of such interfaces, is it possible to identify specific search and learning strategies? And if so, can we use this information to predict future actions? In addition to better understanding the cognitive processes underlying sequential decision making, this could allow building adaptive interfaces that can facilitate interaction at different moments of the learning curve. Here we tackle the question of modeling sequential decision-making behavior in a simple human-computer interface that instantiates a 4-level binary decision tree (BDT task. We record behavioral data from voluntary participants while they attempt to solve the task. Using a Hidden Markov Model-based approach that capitalizes on the hierarchical structure of behavior, we then model their performance during the interaction. Our results show that partitioning the problem space into a small set of hierarchically related stereotyped strategies can potentially capture a host of individual decision making policies. This allows us to follow how participants learn and develop expertise in the use of the interface. Moreover, using a Mixture of Experts based on these stereotyped strategies, the model is able to predict the behavior of participants that master the task.

  1. Fast-Acquisition/Weak-Signal-Tracking GPS Receiver for HEO

    Science.gov (United States)

    Wintemitz, Luke; Boegner, Greg; Sirotzky, Steve

    2004-01-01

    A report discusses the technical background and design of the Navigator Global Positioning System (GPS) receiver -- . a radiation-hardened receiver intended for use aboard spacecraft. Navigator is capable of weak signal acquisition and tracking as well as much faster acquisition of strong or weak signals with no a priori knowledge or external aiding. Weak-signal acquisition and tracking enables GPS use in high Earth orbits (HEO), and fast acquisition allows for the receiver to remain without power until needed in any orbit. Signal acquisition and signal tracking are, respectively, the processes of finding and demodulating a signal. Acquisition is the more computationally difficult process. Previous GPS receivers employ the method of sequentially searching the two-dimensional signal parameter space (code phase and Doppler). Navigator exploits properties of the Fourier transform in a massively parallel search for the GPS signal. This method results in far faster acquisition times [in the lab, 12 GPS satellites have been acquired with no a priori knowledge in a Low-Earth-Orbit (LEO) scenario in less than one second]. Modeling has shown that Navigator will be capable of acquiring signals down to 25 dB-Hz, appropriate for HEO missions. Navigator is built using the radiation-hardened ColdFire microprocessor and housing the most computationally intense functions in dedicated field-programmable gate arrays. The high performance of the algorithm and of the receiver as a whole are made possible by optimizing computational efficiency and carefully weighing tradeoffs among the sampling rate, data format, and data-path bit width.

  2. Sequential Acquisition of Anal Human Papillomavirus (HPV) Infection Following Genital Infection Among Men Who Have Sex With Women: The HPV Infection in Men (HIM) Study.

    Science.gov (United States)

    Pamnani, Shitaldas J; Nyitray, Alan G; Abrahamsen, Martha; Rollison, Dana E; Villa, Luisa L; Lazcano-Ponce, Eduardo; Huang, Yangxin; Borenstein, Amy; Giuliano, Anna R

    2016-10-15

    The purpose of this study was to assess the risk of sequential acquisition of anal human papillomavirus (HPV) infection following a type-specific genital HPV infection for the 9-valent vaccine HPV types and investigate factors associated with sequential infection among men who have sex with women (MSW). Genital and anal specimens were available for 1348 MSW participants, and HPV genotypes were detected using the Roche Linear Array assay. Sequential risk of anal HPV infection was assessed using hazard ratios (HRs) among men with prior genital infection, compared with men with no prior genital infection, in individual HPV type and grouped HPV analyses. In individual analyses, men with prior HPV 16 genital infections had a significantly higher risk of subsequent anal HPV 16 infections (HR, 4.63; 95% confidence interval [CI], 1.41-15.23). In grouped analyses, a significantly higher risk of sequential type-specific anal HPV infections was observed for any of the 9 types (adjusted HR, 2.80; 95% CI, 1.32-5.99), high-risk types (adjusted HR, 2.65; 95% CI, 1.26, 5.55), and low-risk types (adjusted HR, 5.89; 95% CI, 1.29, 27.01). MSW with prior genital HPV infections had a higher risk of a subsequent type-specific anal infection. The higher risk was not explained by sexual intercourse with female partners. Autoinoculation is a possible mechanism for the observed association. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  3. Sodium magnetic resonance imaging. Development of a 3D radial acquisition technique with optimized k-space sampling density and high SNR-efficiency; Natrium-Magnetresonanztomographie. Entwicklung einer 3D radialen Messtechnik mit optimierter k-Raum-Abtastdichte und hoher SNR-Effizienz

    Energy Technology Data Exchange (ETDEWEB)

    Nagel, Armin Michael

    2009-04-01

    A 3D radial k-space acquisition technique with homogenous distribution of the sampling density (DA-3D-RAD) is presented. This technique enables short echo times (TE<0.5 ms), that are necessary for {sup 23}Na-MRI, and provides a high SNR-efficiency. The gradients of the DA-3D-RAD-sequence are designed such that the average sampling density in each spherical shell of k-space is constant. The DA-3D-RAD-sequence provides 34% more SNR than a conventional 3D radial sequence (3D-RAD) if T{sub 2}{sup *}-decay is neglected. This SNR-gain is enhanced if T{sub 2}{sup *}-decay is present, so a 1.5 to 1.8 fold higher SNR is measured in brain tissue with the DA-3D-RAD-sequence. Simulations and experimental measurements show that the DA-3D-RAD sequence yields a better resolution in the presence of T{sub 2}{sup *}-decay and less image artefacts when B{sub 0}-inhomogeneities exist. Using the developed sequence, T{sub 1}-, T{sub 2}{sup *}- and Inversion-Recovery-{sup 23}Na-image contrasts were acquired for several organs and {sup 23}Na-relaxation times were measured (brain tissue: T{sub 1}=29.0{+-}0.3 ms; T{sub 2s}{sup *}{approx}4 ms; T{sub 2l}{sup *}{approx}31 ms; cerebrospinal fluid: T{sub 1}=58.1{+-}0.6 ms; T{sub 2}{sup *}=55{+-}3 ms (B{sub 0}=3 T)). T{sub 1}- und T{sub 2}{sup *}-relaxation times of cerebrospinal fluid are independent of the selected magnetic field strength (B0 = 3T/7 T), whereas the relaxation times of brain tissue increase with field strength. Furthermore, {sup 23}Na-signals of oedemata were suppressed in patients and thus signals from different tissue compartments were selectively measured. (orig.)

  4. Sequential versus simultaneous market delineation

    DEFF Research Database (Denmark)

    Haldrup, Niels; Møllgaard, Peter; Kastberg Nielsen, Claus

    2005-01-01

    and geographical markets. Using a unique data setfor prices of Norwegian and Scottish salmon, we propose a methodologyfor simultaneous market delineation and we demonstrate that comparedto a sequential approach conclusions will be reversed.JEL: C3, K21, L41, Q22Keywords: Relevant market, econometric delineation......Delineation of the relevant market forms a pivotal part of most antitrustcases. The standard approach is sequential. First the product marketis delineated, then the geographical market is defined. Demand andsupply substitution in both the product dimension and the geographicaldimension...

  5. Continued Data Acquisition Development

    Energy Technology Data Exchange (ETDEWEB)

    Schwellenbach, David [National Security Technologies, LLC. (NSTec), Mercury, NV (United States)

    2017-11-27

    This task focused on improving techniques for integrating data acquisition of secondary particles correlated in time with detected cosmic-ray muons. Scintillation detectors with Pulse Shape Discrimination (PSD) capability show the most promise as a detector technology based on work in FY13. Typically PSD parameters are determined prior to an experiment and the results are based on these parameters. By saving data in list mode, including the fully digitized waveform, any experiment can effectively be replayed to adjust PSD and other parameters for the best data capture. List mode requires time synchronization of two independent data acquisitions (DAQ) systems: the muon tracker and the particle detector system. Techniques to synchronize these systems were studied. Two basic techniques were identified: real time mode and sequential mode. Real time mode is the preferred system but has proven to be a significant challenge since two FPGA systems with different clocking parameters must be synchronized. Sequential processing is expected to work with virtually any DAQ but requires more post processing to extract the data.

  6. Sequential acquisition of mutations in myelodysplastic syndromes.

    Science.gov (United States)

    Makishima, Hideki

    2017-01-01

    Recent progress in next-generation sequencing technologies allows us to discover frequent mutations throughout the coding regions of myelodysplastic syndromes (MDS), potentially providing us with virtually a complete spectrum of driver mutations in this disease. As shown by many study groups these days, such driver mutations are acquired in a gene-specific fashion. For instance, DDX41 mutations are observed in germline cells long before MDS presentation. In blood samples from healthy elderly individuals, somatic DNMT3A and TET2 mutations are detected as age-related clonal hematopoiesis and are believed to be a risk factor for hematological neoplasms. In MDS, mutations of genes such as NRAS and FLT3, designated as Type-1 genes, may be significantly associated with leukemic evolution. Another type (Type-2) of genes, including RUNX1 and GATA2, are related to progression from low-risk to high-risk MDS. Overall, various driver mutations are sequentially acquired in MDS, at a specific time, in either germline cells, normal hematopoietic cells, or clonal MDS cells.

  7. Fast MR image reconstruction for partially parallel imaging with arbitrary k-space trajectories.

    Science.gov (United States)

    Ye, Xiaojing; Chen, Yunmei; Lin, Wei; Huang, Feng

    2011-03-01

    Both acquisition and reconstruction speed are crucial for magnetic resonance (MR) imaging in clinical applications. In this paper, we present a fast reconstruction algorithm for SENSE in partially parallel MR imaging with arbitrary k-space trajectories. The proposed method is a combination of variable splitting, the classical penalty technique and the optimal gradient method. Variable splitting and the penalty technique reformulate the SENSE model with sparsity regularization as an unconstrained minimization problem, which can be solved by alternating two simple minimizations: One is the total variation and wavelet based denoising that can be quickly solved by several recent numerical methods, whereas the other one involves a linear inversion which is solved by the optimal first order gradient method in our algorithm to significantly improve the performance. Comparisons with several recent parallel imaging algorithms indicate that the proposed method significantly improves the computation efficiency and achieves state-of-the-art reconstruction quality.

  8. Sequential memory: Binding dynamics

    Science.gov (United States)

    Afraimovich, Valentin; Gong, Xue; Rabinovich, Mikhail

    2015-10-01

    Temporal order memories are critical for everyday animal and human functioning. Experiments and our own experience show that the binding or association of various features of an event together and the maintaining of multimodality events in sequential order are the key components of any sequential memories—episodic, semantic, working, etc. We study a robustness of binding sequential dynamics based on our previously introduced model in the form of generalized Lotka-Volterra equations. In the phase space of the model, there exists a multi-dimensional binding heteroclinic network consisting of saddle equilibrium points and heteroclinic trajectories joining them. We prove here the robustness of the binding sequential dynamics, i.e., the feasibility phenomenon for coupled heteroclinic networks: for each collection of successive heteroclinic trajectories inside the unified networks, there is an open set of initial points such that the trajectory going through each of them follows the prescribed collection staying in a small neighborhood of it. We show also that the symbolic complexity function of the system restricted to this neighborhood is a polynomial of degree L - 1, where L is the number of modalities.

  9. A singular K-space model for fast reconstruction of magnetic resonance images from undersampled data.

    Science.gov (United States)

    Luo, Jianhua; Mou, Zhiying; Qin, Binjie; Li, Wanqing; Ogunbona, Philip; Robini, Marc C; Zhu, Yuemin

    2017-12-09

    Reconstructing magnetic resonance images from undersampled k-space data is a challenging problem. This paper introduces a novel method of image reconstruction from undersampled k-space data based on the concept of singularizing operators and a novel singular k-space model. Exploring the sparsity of an image in the k-space, the singular k-space model (SKM) is proposed in terms of the k-space functions of a singularizing operator. The singularizing operator is constructed by combining basic difference operators. An algorithm is developed to reliably estimate the model parameters from undersampled k-space data. The estimated parameters are then used to recover the missing k-space data through the model, subsequently achieving high-quality reconstruction of the image using inverse Fourier transform. Experiments on physical phantom and real brain MR images have shown that the proposed SKM method constantly outperforms the popular total variation (TV) and the classical zero-filling (ZF) methods regardless of the undersampling rates, the noise levels, and the image structures. For the same objective quality of the reconstructed images, the proposed method requires much less k-space data than the TV method. The SKM method is an effective method for fast MRI reconstruction from the undersampled k-space data. Graphical abstract Two Real Images and their sparsified images by singularizing operator.

  10. Complete k-space visualization of x-ray photoelectron diffraction

    International Nuclear Information System (INIS)

    Denlinger, J.D.; Lawrence Berkeley Lab., CA; Rotenberg, E.; Lawrence Berkeley Lab., CA; Kevan, S.D.; Tonner, B.P.

    1996-01-01

    A highly detailed x-ray photoelectron diffraction data set has been acquired for crystalline Cu(001). The data set for bulk Cu 3p emission encompasses a large k-space volume (k = 3--10 angstrom -1 ) with sufficient energy and angular sampling to monitor the continuous variation of diffraction intensities. The evolution of back-scattered intensity oscillations is visualized by energy and angular slices of this volume data set. Large diffraction data sets such as this will provide rigorous experimental tests of real-space reconstruction algorithms and multiple-scattering simulations

  11. Comparison of image quality between 70 kVp and 80 kVp: application to paediatric cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Durand, Sebastien [Centre Chirurgical Marie Lannelongue, Radiology Department, Le Plessis-Robinson (France); Paul, Jean-Francois [Institut Mutualiste Montsouris, Radiology Department, Paris (France)

    2014-12-15

    To evaluate noise level and contrast-to-noise ratio (CNR) with various kVp-mAs pairs producing the same computed tomography dose index (CTDI) value. The 80 kVp and new 70-kVp settings were compared. The noise was measured in 10 ovoid water phantoms with different diameters from 10 cm to 28 cm. Contrast was obtained from CTs of iodine-filled tubes. Spiral acquisition protocols at 70 kVp and 80 kVp, with the same CTDI, were applied. In the clinical study, two matched groups, each of 21 paediatric patients, underwent 70-kVp or 80-kVp ECG-gated iodinated-enhanced sequential CT. Noise was significantly higher with 70 kVp than 80-kVp settings for all phantom sizes. Estimated CNR with phantoms was higher at 70 kVp than 80 kVp, and the difference decreased from 17 % to 3 % as phantom size increased. The mean CNR in paediatric patients was 15.2 at 70 kVp and 14.3 at 80 kVp (ns). The CNR difference was significantly larger in the small-child subgroup. Noise level is slightly higher at the 70-kVp than the 80-kVp setting, but the CNR is higher, particularly for small children. Therefore, 70 kVp may be appropriate for contrast-enhanced CT examinations and 80 kVp for non-enhanced CT in small children. (orig.)

  12. Validation of a motion-robust 2D sequential technique for quantification of hepatic proton density fat fraction during free breathing.

    Science.gov (United States)

    Pooler, B Dustin; Hernando, Diego; Ruby, Jeannine A; Ishii, Hiroshi; Shimakawa, Ann; Reeder, Scott B

    2018-04-17

    Current chemical-shift-encoded (CSE) MRI techniques for measuring hepatic proton density fat fraction (PDFF) are sensitive to motion artifacts. Initial validation of a motion-robust 2D-sequential CSE-MRI technique for quantification of hepatic PDFF. Phantom study and prospective in vivo cohort. Fifty adult patients (27 women, 23 men, mean age 57.2 years). 3D, 2D-interleaved, and 2D-sequential CSE-MRI acquisitions at 1.5T. Three CSE-MRI techniques (3D, 2D-interleaved, 2D-sequential) were performed in a PDFF phantom and in vivo. Reference standards were 3D CSE-MRI PDFF measurements for the phantom study and single-voxel MR spectroscopy hepatic PDFF measurements (MRS-PDFF) in vivo. In vivo hepatic MRI-PDFF measurements were performed during a single breath-hold (BH) and free breathing (FB), and were repeated by a second reader for the FB 2D-sequential sequence to assess interreader variability. Correlation plots to validate the 2D-sequential CSE-MRI against the phantom and in vivo reference standards. Bland-Altman analysis of FB versus BH CSE-MRI acquisitions to evaluate robustness to motion. Bland-Altman analysis to assess interreader variability. Phantom 2D-sequential CSE-MRI PDFF measurements demonstrated excellent agreement and correlation (R 2 > 0.99) with 3D CSE-MRI. In vivo, the mean (±SD) hepatic PDFF was 8.8 ± 8.7% (range 0.6-28.5%). Compared with BH acquisitions, FB hepatic PDFF measurements demonstrated bias of +0.15% for 2D-sequential compared with + 0.53% for 3D and +0.94% for 2D-interleaved. 95% limits of agreement (LOA) were narrower for 2D-sequential (±0.99%), compared with 3D (±3.72%) and 2D-interleaved (±3.10%). All CSE-MRI techniques had excellent correlation with MRS (R 2 > 0.97). The FB 2D-sequential acquisition demonstrated little interreader variability, with mean bias of +0.07% and 95% LOA of ± 1.53%. This motion-robust 2D-sequential CSE-MRI can accurately measure hepatic PDFF during free breathing in a patient population with

  13. 78 FR 75676 - Mark W. Dobronski and Susan K. Dobronski-Acquisition of Control Exemption-Adrian & Blissfield...

    Science.gov (United States)

    2013-12-12

    ... Ferrovia, L.L.C. (Ferrovia), also a noncarrier and a limited liability company, which, until very recently... and Susan K. Dobronski--Acquisition of Control Exemption--Adrian & Blissfield Rail Road Company, Charlotte Southern Railroad Company, Detroit Connecting Railroad Company, Lapeer Industrial Railroad Company...

  14. Automatic Control and Data Acquisition System for Combustion Laboratory Applications.

    Science.gov (United States)

    1982-10-01

    O VPI Access~.ion FCr- 1473 2 UNCLASSIFIED Approved for public release; distribution unlimited JAutomatic Control and Data Acquisition System for...unit. The CPU/ROK board includes a 16 bit microprocessor chip which decodes and executes all in- structions, and controls all data transfers. The 12K...in the limited memory space of 32K of the HP-85 33 ACQDTA’ 1) Controls DevicesCRAIN ,2) Acquires Photodiods Output$ 3) Stores Data o Disc 1

  15. A path-level exact parallelization strategy for sequential simulation

    Science.gov (United States)

    Peredo, Oscar F.; Baeza, Daniel; Ortiz, Julián M.; Herrero, José R.

    2018-01-01

    Sequential Simulation is a well known method in geostatistical modelling. Following the Bayesian approach for simulation of conditionally dependent random events, Sequential Indicator Simulation (SIS) method draws simulated values for K categories (categorical case) or classes defined by K different thresholds (continuous case). Similarly, Sequential Gaussian Simulation (SGS) method draws simulated values from a multivariate Gaussian field. In this work, a path-level approach to parallelize SIS and SGS methods is presented. A first stage of re-arrangement of the simulation path is performed, followed by a second stage of parallel simulation for non-conflicting nodes. A key advantage of the proposed parallelization method is to generate identical realizations as with the original non-parallelized methods. Case studies are presented using two sequential simulation codes from GSLIB: SISIM and SGSIM. Execution time and speedup results are shown for large-scale domains, with many categories and maximum kriging neighbours in each case, achieving high speedup results in the best scenarios using 16 threads of execution in a single machine.

  16. Production and processing asymmetries in the acquisition of tense morphology by sequential bilingual children

    DEFF Research Database (Denmark)

    Chondrogianni, Vicky; Marinis, Theodoros

    2011-01-01

    This study investigates the production and online processing of English tense morphemes by sequential bilingual (L2) Turkish-speaking children with more than three years of exposure to English. Thirty-nine six- to nine-year-old L2 children and twenty-eight typically developing age-matched monolin......This study investigates the production and online processing of English tense morphemes by sequential bilingual (L2) Turkish-speaking children with more than three years of exposure to English. Thirty-nine six- to nine-year-old L2 children and twenty-eight typically developing age...

  17. Sequential Bayesian geoacoustic inversion for mobile and compact source-receiver configuration.

    Science.gov (United States)

    Carrière, Olivier; Hermand, Jean-Pierre

    2012-04-01

    Geoacoustic characterization of wide areas through inversion requires easily deployable configurations including free-drifting platforms, underwater gliders and autonomous vehicles, typically performing repeated transmissions during their course. In this paper, the inverse problem is formulated as sequential Bayesian filtering to take advantage of repeated transmission measurements. Nonlinear Kalman filters implement a random-walk model for geometry and environment and an acoustic propagation code in the measurement model. Data from MREA/BP07 sea trials are tested consisting of multitone and frequency-modulated signals (bands: 0.25-0.8 and 0.8-1.6 kHz) received on a shallow vertical array of four hydrophones 5-m spaced drifting over 0.7-1.6 km range. Space- and time-coherent processing are applied to the respective signal types. Kalman filter outputs are compared to a sequence of global optimizations performed independently on each received signal. For both signal types, the sequential approach is more accurate but also more efficient. Due to frequency diversity, the processing of modulated signals produces a more stable tracking. Although an extended Kalman filter provides comparable estimates of the tracked parameters, the ensemble Kalman filter is necessary to properly assess uncertainty. In spite of mild range dependence and simplified bottom model, all tracked geoacoustic parameters are consistent with high-resolution seismic profiling, core logging P-wave velocity, and previous inversion results with fixed geometries.

  18. Generalized infimum and sequential product of quantum effects

    International Nuclear Information System (INIS)

    Li Yuan; Sun Xiuhong; Chen Zhengli

    2007-01-01

    The quantum effects for a physical system can be described by the set E(H) of positive operators on a complex Hilbert space H that are bounded above by the identity operator I. For A, B(set-membership sign)E(H), the operation of sequential product A(convolution sign)B=A 1/2 BA 1/2 was proposed as a model for sequential quantum measurements. A nice investigation of properties of the sequential product has been carried over [Gudder, S. and Nagy, G., 'Sequential quantum measurements', J. Math. Phys. 42, 5212 (2001)]. In this note, we extend some results of this reference. In particular, a gap in the proof of Theorem 3.2 in this reference is overcome. In addition, some properties of generalized infimum A sqcap B are studied

  19. Full k-space visualization of photoelectron diffraction

    International Nuclear Information System (INIS)

    Denlinger, J.D.; Rotenberg, E.; Kevan, S.D.; Tonner, B.P.

    1997-01-01

    The development of photoelectron holography has promoted the need for larger photoelectron diffraction data sets in order to improve the quality of real-space reconstructed images (by suppressing transformational artifacts and distortions). The two main experimental and theoretical approaches to holography, the transform of angular distribution patterns for a coarse selection of energies or the transform of energy-scanned profiles for several directions, represent two limits to k-space sampling. The high brightness of third-generation soft x-ray synchrotron sources provides the opportunity to rapidly measure large high-density x-ray photoelectron diffraction (XPD) data sets with approximately uniform k-space sampling. In this abstract, the authors present such a photoelectron data set acquired for Cu 3p emission from Cu(001). Cu(001) is one of the most well-studied systems for understanding photoelectron diffraction structure and for testing photoelectron holography methods. Cu(001) was chosen for this study in part due to the relatively inert and unreconstructed clean surface, and it served to calibrate and fine-tune the operation of a new synchrotron beamline, electron spectrometer and sample goniometer. In addition to Cu, similar open-quotes volumeclose quotes XPD data sets have been acquired for bulk and surface core-level emission from W(110), from reconstructed Si(100) and Si(111) surfaces, and from the adsorbate system of c(2x2) Mn/Ni(100)

  20. Motion-robust diffusion tensor acquisition at routine 3T magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yasmin, Hasina; Abe, Osamu; Masutani, Yoshitaka; Hayashi, Naoto; Ohtomo, Kuni; Kabasawa, Hiroyuki; Aoki, Shigeki

    2010-01-01

    We compared different acquisition and reconstruction methods in phantom and human studies in the clinical setting to validate our hypothesis that optimizing the k-space acquisition and reconstruction method could decrease motion artifacts. Diffusion tensor images of a water phantom were obtained with three table displacement magnitudes: 1 mm, 2 mm, and 3 mm. Images were reconstructed using homodyne and zero-fill reconstruction. Overscanning in 8- and 16-k y lines was tested. We performed visual assessment of the artifacts using reconstructed coronal images and analyzed them with Wilcoxon signed-ranks test both for phantom and human studies. Also, fractional anisotropy (FA) changes between acquisition methods were compared. Artifacts due to smaller displacement (1 and 2 mm) were significantly reduced in 16-k y overscan with zero filling. The Wilcoxon signed-ranks test showed significant differences (P<0.031 for reconstruction methods and P<0.016 for overscanning methods). FA changes were statistically significant (P<0.037; Student's t-test). The Wilcoxon signed-ranks test showed significant reductions (P<0.005) in the human study. Motion-induced artifacts can be reduced by optimizing acquisition and reconstruction methods. The techniques described in this study offer an effective method for robust estimation of diffusion tensor in the presence of motion-related artifactual data points. (author)

  1. Redefining orthodontic space closure: sequential repetitive loading of the periodontal ligament--a clinical study.

    Science.gov (United States)

    Kalha, Anmol S; Kachiwala, Viral Ashok; Govardhan, Singatagere Nagaraj; McLaughlin, Richard P; Khurshaid, Syed Zameer

    2010-01-01

    To assess the rate of tooth movement, anchorage loss, root resorption, and alkaline phosphatase (ALP) activity in the gingival crevicular fluid (GCF) as a marker for bone remodeling during orthodontic space closure using two different mechanisms. Space closure was completed in 20 patients with extraction of all 4 premolars. Lateral cephalograms and radio-visiographs taken before (T1) and after (T2) space closure were assessed for anchorage loss and root resorption. Alkaline phosphatase levels were measured in 10 patients, which were divided into two groups of five each. Spaces were closed with a screw device in the first group and with active tie-backs in the second. Gingival crevicular fluid samples, collected at intervals, were assayed for alkaline phosphatase spectrophotometrically in each patient. The mean rate of tooth movement was 1.32 ± 0.22 mm/month. The mean amount of anchorage loss in the maxilla and mandible was 1.23 ± 0.60 mm and 1.08 ± 0.65 mm, respectively. Sixty (25%) roots showed no root resorption, while 180 (75%) roots displayed mild to moderate blunting of their apices. Gingival crevicular fluid-alkaline phosphatase level increased significantly from day 7 to day 28 in both groups, but significantly more in the screw retraction group (Pspace closure occurs more rapidly with sequential repetitive loading of the periodontal ligament than with conventional active tie-backs. This observation is in concurrence with a significant increase in the gingival crevicular fluid-alkaline phosphatase level. © 2010 BY QUINTESSENCE PUBLISHING CO, INC.

  2. Distributing learning over time: the spacing effect in children's acquisition and generalization of science concepts.

    Science.gov (United States)

    Vlach, Haley A; Sandhofer, Catherine M

    2012-01-01

    The spacing effect describes the robust finding that long-term learning is promoted when learning events are spaced out in time rather than presented in immediate succession. Studies of the spacing effect have focused on memory processes rather than for other types of learning, such as the acquisition and generalization of new concepts. In this study, early elementary school children (5- to 7-year-olds; N = 36) were presented with science lessons on 1 of 3 schedules: massed, clumped, and spaced. The results revealed that spacing lessons out in time resulted in higher generalization performance for both simple and complex concepts. Spaced learning schedules promote several types of learning, strengthening the implications of the spacing effect for educational practices and curriculum. © 2012 The Authors. Child Development © 2012 Society for Research in Child Development, Inc.

  3. Comparison of Coregistration Accuracy of Pelvic Structures Between Sequential and Simultaneous Imaging During Hybrid PET/MRI in Patients with Bladder Cancer.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Balar, Arjun V; Huang, William C; Jackson, Kimberly; Friedman, Kent P

    2015-08-01

    The aim of this study was to compare coregistration of the bladder wall, bladder masses, and pelvic lymph nodes between sequential and simultaneous PET and MRI acquisitions obtained during hybrid (18)F-FDG PET/MRI performed using a diuresis protocol in bladder cancer patients. Six bladder cancer patients underwent (18)F-FDG hybrid PET/MRI, including IV Lasix administration and oral hydration, before imaging to achieve bladder clearance. Axial T2-weighted imaging (T2WI) was obtained approximately 40 minutes before PET ("sequential") and concurrently with PET ("simultaneous"). Three-dimensional spatial coordinates of the bladder wall, bladder masses, and pelvic lymph nodes were recorded for PET and T2WI. Distances between these locations on PET and T2WI sequences were computed and used to compare in-plane (x-y plane) and through-plane (z-axis) misregistration relative to PET between T2WI acquisitions. The bladder increased in volume between T2WI acquisitions (sequential, 176 [139] mL; simultaneous, 255 [146] mL). Four patients exhibited a bladder mass, all with increased activity (SUV, 9.5-38.4). Seven pelvic lymph nodes in 4 patients showed increased activity (SUV, 2.2-9.9). The bladder wall exhibited substantially less misregistration relative to PET for simultaneous, compared with sequential, acquisitions in in-plane (2.8 [3.1] mm vs 7.4 [9.1] mm) and through-plane (1.7 [2.2] mm vs 5.7 [9.6] mm) dimensions. Bladder masses exhibited slightly decreased misregistration for simultaneous, compared with sequential, acquisitions in in-plane (2.2 [1.4] mm vs 2.6 [1.9] mm) and through-plane (0.0 [0.0] mm vs 0.3 [0.8] mm) dimensions. FDG-avid lymph nodes exhibited slightly decreased in-plane misregistration (1.1 [0.8] mm vs 2.5 [0.6] mm), although identical through-plane misregistration (4.0 [1.9] mm vs 4.0 [2.8] mm). Using hybrid PET/MRI, simultaneous imaging substantially improved bladder wall coregistration and slightly improved coregistration of bladder masses and

  4. Data acquisition

    International Nuclear Information System (INIS)

    Clout, P.N.

    1982-01-01

    Data acquisition systems are discussed for molecular biology experiments using synchrotron radiation sources. The data acquisition system requirements are considered. The components of the solution are described including hardwired solutions and computer-based solutions. Finally, the considerations for the choice of the computer-based solution are outlined. (U.K.)

  5. 1024-65536 channel nuclear spectrum data acquisition and processing system

    Energy Technology Data Exchange (ETDEWEB)

    Songjiang, Xia

    1987-09-01

    A multiscale data acquisition and processing system based on IBM PC/XT microcomputer is described. In this system, not only 1024,2048,4096 single parameter spectrum, but also 128 x 128, 256 x 256 dual parameter spectrum can be acquisited. The interface logic is designed to work at sequential recording DMA mode, the total avergage time for recording each descriptor is 7.5 ..mu..s.

  6. Selection of a Data Acquisition and Controls System Communications and Software Architecture for Johnson Space Center's Space Environment Simulation Laboratory Thermal and Vacuum Test Facilities

    Science.gov (United States)

    Jordan, Eric A.

    2004-01-01

    Upgrade of data acquisition and controls systems software at Johnson Space Center's Space Environment Simulation Laboratory (SESL) involved the definition, evaluation and selection of a system communication architecture and software components. A brief discussion of the background of the SESL and its data acquisition and controls systems provides a context for discussion of the requirements for each selection. Further framework is provided as upgrades to these systems accomplished in the 1990s and in 2003 are compared to demonstrate the role that technological advances have had in their improvement. Both of the selections were similar in their three phases; 1) definition of requirements, 2) identification of candidate products and their evaluation and testing and 3) selection by comparison of requirement fulfillment. The candidates for the communication architecture selection embraced several different methodologies which are explained and contrasted. Requirements for this selection are presented and the selection process is described. Several candidates for the software component of the data acquisition and controls system are identified, requirements for evaluation and selection are presented, and the evaluation process is described.

  7. Liquid chromatography, in combination with a quadrupole time-of-flight instrument (LC QTOF), with sequential window acquisition of all theoretical fragment-ion spectra (SWATH) acquisition: systematic studies on its use for screenings in clinical and forensic toxicology and comparison with information-dependent acquisition (IDA).

    Science.gov (United States)

    Roemmelt, Andreas T; Steuer, Andrea E; Poetzsch, Michael; Kraemer, Thomas

    2014-12-02

    Forensic and clinical toxicological screening procedures are employing liquid chromatography-tandem mass spectrometry (LC-MS/MS) techniques with information-dependent acquisition (IDA) approaches more and more often. It is known that the complexity of a sample and the IDA settings might prevent important compounds from being triggered. Therefore, data-independent acquisition (DIA) methods should be more suitable for systematic toxicological analysis (STA). The DIA method sequential window acquisition of all theoretical fragment-ion spectra (SWATH), which uses Q1 windows of 20-35 Da for data-independent fragmentation, was systematically investigated for its suitability for STA. Quality of SWATH-generated mass spectra were evaluated with regard to mass error, relative abundance of the fragments, and library hits. With the Q1 window set to 20-25 Da, several precursors pass Q1 at the same time and are fragmented, thus impairing the library search algorithms to a different extent: forward fit was less affected than reverse fit and purity fit. Mass error was not affected. The relative abundance of the fragments was concentration dependent for some analytes and was influenced by cofragmentation, especially of deuterated analogues. Also, the detection rate of IDA compared to SWATH was investigated in a forced coelution experiment (up to 20 analytes coeluting). Even using several different IDA settings, it was observed that IDA failed to trigger relevant compounds. Screening results of 382 authentic forensic cases revealed that SWATH's detection rate was superior to IDA, which failed to trigger ∼10% of the analytes.

  8. Space Access for Small Satellites on the K-1

    Science.gov (United States)

    Faktor, L.

    Affordable access to space remains a major obstacle to realizing the increasing potential of small satellites systems. On a per kilogram basis, small launch vehicles are simply too expensive for the budgets of many small satellite programs. Opportunities for rideshare with larger payloads on larger launch vehicles are still rare, given the complications associated with coordinating delivery schedules and deployment orbits. Existing contractual mechanisms are also often inadequate to facilitate the launch of multiple payload customers on the same flight. Kistler Aerospace Corporation is committed to lowering the price and enhancing the availability of space access for small satellite programs through the fully-reusable K-1 launch vehicle. Kistler has been working with a number of entities, including Astrium Ltd., AeroAstro, and NASA, to develop innovative approaches to small satellite missions. The K-1 has been selected by NASA as a Flight Demonstration Vehicle for the Space Launch Initiative. NASA has purchased the flight results during the first four K-1 launches on the performance of 13 advanced launch vehicle technologies embedded in the K-1 vehicle. On K-1 flights #2-#4, opportunities exist for small satellites to rideshare to low-earth orbit for a low-launch price. Kistler's flight demonstration contract with NASA also includes options to fly Add-on Technology Experiment flights. Opportunities exist for rideshare payloads on these flights as well. Both commercial and government customers may take advantage of the rideshare pricing. Kistler is investigating the feasibility of flying dedicated, multiple small payload missions. Such a mission would launch multiple small payloads from a single customer or small payloads from different customers. The orbit would be selected to be compatible with the requirements of as many small payload customers as possible, and make use of reusable hardware, standard interfaces (such as the existing MPAS) and verification plans

  9. Performance analysis of coherent free space optical communications with sequential pyramid wavefront sensor

    Science.gov (United States)

    Liu, Wei; Yao, Kainan; Chen, Lu; Huang, Danian; Cao, Jingtai; Gu, Haijun

    2018-03-01

    Based-on the previous study on the theory of the sequential pyramid wavefront sensor (SPWFS), in this paper, the SPWFS is first applied to the coherent free space optical communications (FSOC) with more flexible spatial resolution and higher sensitivity than the Shack-Hartmann wavefront sensor, and with higher uniformity of intensity distribution and much simpler than the pyramid wavefront sensor. Then, the mixing efficiency (ME) and the bit error rate (BER) of the coherent FSOC are analyzed during the aberrations correction through numerical simulation with binary phase shift keying (BPSK) modulation. Finally, an experimental AO system based-on SPWFS is setup, and the experimental data is used to analyze the ME and BER of homodyne detection with BPSK modulation. The results show that the AO system based-on SPWFS can increase ME and decrease BER effectively. The conclusions of this paper provide a new method of wavefront sensing for designing the AO system for a coherent FSOC system.

  10. A new design and rationale for 3D orthogonally oversampled k-space trajectories.

    Science.gov (United States)

    Pipe, James G; Zwart, Nicholas R; Aboussouan, Eric A; Robison, Ryan K; Devaraj, Ajit; Johnson, Kenneth O

    2011-11-01

    A novel center-out 3D trajectory for sampling magnetic resonance data is presented. The trajectory set is based on a single Fermat spiral waveform, which is substantially undersampled in the center of k-space. Multiple trajectories are combined in a "stacked cone" configuration to give very uniform sampling throughout a "hub," which is very efficient in terms of gradient performance and uniform trajectory spacing. The fermat looped, orthogonally encoded trajectories (FLORET) design produces less gradient-efficient trajectories near the poles, so multiple orthogonal hub designs are shown. These multihub designs oversample k-space twice with orthogonal trajectories, which gives unique properties but also doubles the minimum scan time for critical sampling of k-space. The trajectory is shown to be much more efficient than the conventional stack of cones trajectory, and has nearly the same signal-to-noise ratio efficiency (but twice the minimum scan time) as a stack of spirals trajectory. As a center-out trajectory, it provides a shorter minimum echo time than stack of spirals, and its spherical k-space coverage can dramatically reduce Gibbs ringing. Copyright © 2011 Wiley Periodicals, Inc.

  11. Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

    Science.gov (United States)

    Robson, Philip M; Grant, Aaron K; Madhuranthakam, Ananth J; Lattanzi, Riccardo; Sodickson, Daniel K; McKenzie, Charles A

    2008-10-01

    Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise ratio and g-factor and is demonstrated for SENSE and GRAPPA reconstructions for accelerated acquisitions that have not previously been amenable to such assessment. Only a simple "prescan" measurement of noise amplitude and correlation in the phased-array receiver, and a single accelerated image acquisition are required, allowing robust assessment of signal-to-noise ratio and g-factor. The "pseudo multiple replica" method has been rigorously validated in phantoms and in vivo, showing excellent agreement with true multiple replica and analytical methods. This method is universally applicable to the parallel imaging reconstruction techniques used in clinical applications and will allow pixel-by-pixel image noise measurements for all parallel imaging strategies, allowing quantitative comparison between arbitrary k-space trajectories, image reconstruction, or noise conditioning techniques. (c) 2008 Wiley-Liss, Inc.

  12. High-Resolution DCE-MRI of the Pituitary Gland Using Radial k-Space Acquisition with Compressed Sensing Reconstruction.

    Science.gov (United States)

    Rossi Espagnet, M C; Bangiyev, L; Haber, M; Block, K T; Babb, J; Ruggiero, V; Boada, F; Gonen, O; Fatterpekar, G M

    2015-08-01

    The pituitary gland is located outside of the blood-brain barrier. Dynamic T1 weighted contrast enhanced sequence is considered to be the gold standard to evaluate this region. However, it does not allow assessment of intrinsic permeability properties of the gland. Our aim was to demonstrate the utility of radial volumetric interpolated brain examination with the golden-angle radial sparse parallel technique to evaluate permeability characteristics of the individual components (anterior and posterior gland and the median eminence) of the pituitary gland and areas of differential enhancement and to optimize the study acquisition time. A retrospective study was performed in 52 patients (group 1, 25 patients with normal pituitary glands; and group 2, 27 patients with a known diagnosis of microadenoma). Radial volumetric interpolated brain examination sequences with golden-angle radial sparse parallel technique were evaluated with an ROI-based method to obtain signal-time curves and permeability measures of individual normal structures within the pituitary gland and areas of differential enhancement. Statistical analyses were performed to assess differences in the permeability parameters of these individual regions and optimize the study acquisition time. Signal-time curves from the posterior pituitary gland and median eminence demonstrated a faster wash-in and time of maximum enhancement with a lower peak of enhancement compared with the anterior pituitary gland (P pituitary gland evaluation. In the absence of a clinical history, differences in the signal-time curves allow easy distinction between a simple cyst and a microadenoma. This retrospective study confirms the ability of the golden-angle radial sparse parallel technique to evaluate the permeability characteristics of the pituitary gland and establishes 120 seconds as the ideal acquisition time for dynamic pituitary gland imaging. © 2015 by American Journal of Neuroradiology.

  13. Sequential-Simultaneous Analysis of Japanese Children's Performance on the Japanese McCarthy.

    Science.gov (United States)

    Ishikuma, Toshinori; And Others

    This study explored the hypothesis that Japanese children perform significantly better on simultaneous processing than on sequential processing. The Kaufman Assessment Battery for Children (K-ABC) served as the criterion of the two types of mental processing. Regression equations to predict Sequential and Simultaneous processing from McCarthy…

  14. Modulated Acquisition of Spatial Distortion Maps

    Directory of Open Access Journals (Sweden)

    Aleš Švigelj

    2013-08-01

    Full Text Available This work discusses a novel approach to image acquisition which improves the robustness of captured data required for 3D range measurements. By applying a pseudo-random code modulation to sequential acquisition of projected patterns the impact of environmental factors such as ambient light and mutual interference is significantly reduced. The proposed concept has been proven with an experimental range sensor based on the laser triangulation principle. The proposed design can potentially enhance the use of this principle to a variety of outdoor applications, such as autonomous vehicles, pedestrians’ safety, collision avoidance, and many other tasks, where robust real-time distance detection in real world environment is crucial.

  15. Modulated acquisition of spatial distortion maps.

    Science.gov (United States)

    Volkov, Alexey; Gros, Jerneja Zganec; Zganec, Mario; Javornik, Tomaž; Svigelj, Aleš

    2013-08-21

    This work discusses a novel approach to image acquisition which improves the robustness of captured data required for 3D range measurements. By applying a pseudo-random code modulation to sequential acquisition of projected patterns the impact of environmental factors such as ambient light and mutual interference is significantly reduced. The proposed concept has been proven with an experimental range sensor based on the laser triangulation principle. The proposed design can potentially enhance the use of this principle to a variety of outdoor applications, such as autonomous vehicles, pedestrians' safety, collision avoidance, and many other tasks, where robust real-time distance detection in real world environment is crucial.

  16. K-nearest uphill clustering in the protein structure space

    KAUST Repository

    Cui, Xuefeng

    2016-08-26

    The protein structure classification problem, which is to assign a protein structure to a cluster of similar proteins, is one of the most fundamental problems in the construction and application of the protein structure space. Early manually curated protein structure classifications (e.g., SCOP and CATH) are very successful, but recently suffer the slow updating problem because of the increased throughput of newly solved protein structures. Thus, fully automatic methods to cluster proteins in the protein structure space have been designed and developed. In this study, we observed that the SCOP superfamilies are highly consistent with clustering trees representing hierarchical clustering procedures, but the tree cutting is very challenging and becomes the bottleneck of clustering accuracy. To overcome this challenge, we proposed a novel density-based K-nearest uphill clustering method that effectively eliminates noisy pairwise protein structure similarities and identifies density peaks as cluster centers. Specifically, the density peaks are identified based on K-nearest uphills (i.e., proteins with higher densities) and K-nearest neighbors. To our knowledge, this is the first attempt to apply and develop density-based clustering methods in the protein structure space. Our results show that our density-based clustering method outperforms the state-of-the-art clustering methods previously applied to the problem. Moreover, we observed that computational methods and human experts could produce highly similar clusters at high precision values, while computational methods also suggest to split some large superfamilies into smaller clusters. © 2016 Elsevier B.V.

  17. Optimized image acquisition for breast tomosynthesis in projection and reconstruction space

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Lo, Joseph Y.; Baker, Jay A.; Samei, Ehsan

    2009-01-01

    Breast tomosynthesis has been an exciting new development in the field of breast imaging. While the diagnostic improvement via tomosynthesis is notable, the full potential of tomosynthesis has not yet been realized. This may be attributed to the dependency of the diagnostic quality of tomosynthesis on multiple variables, each of which needs to be optimized. Those include dose, number of angular projections, and the total angular span of those projections. In this study, the authors investigated the effects of these acquisition parameters on the overall diagnostic image quality of breast tomosynthesis in both the projection and reconstruction space. Five mastectomy specimens were imaged using a prototype tomosynthesis system. 25 angular projections of each specimen were acquired at 6.2 times typical single-view clinical dose level. Images at lower dose levels were then simulated using a noise modification routine. Each projection image was supplemented with 84 simulated 3 mm 3D lesions embedded at the center of 84 nonoverlapping ROIs. The projection images were then reconstructed using a filtered backprojection algorithm at different combinations of acquisition parameters to investigate which of the many possible combinations maximizes the performance. Performance was evaluated in terms of a Laguerre-Gauss channelized Hotelling observer model-based measure of lesion detectability. The analysis was also performed without reconstruction by combining the model results from projection images using Bayesian decision fusion algorithm. The effect of acquisition parameters on projection images and reconstructed slices were then compared to derive an optimization rule for tomosynthesis. The results indicated that projection images yield comparable but higher performance than reconstructed images. Both modes, however, offered similar trends: Performance improved with an increase in the total acquisition dose level and the angular span. Using a constant dose level and angular

  18. Radiation damage in room-temperature data acquisition with the PILATUS 6M pixel detector

    Energy Technology Data Exchange (ETDEWEB)

    Rajendran, Chitra, E-mail: chitra.rajendran@psi.ch; Dworkowski, Florian S. N.; Wang, Meitian; Schulze-Briese, Clemens [Swiss Light Source at Paul Scherrer Institute, CH-5232 Villigen (Switzerland)

    2011-05-01

    Observations of the dose-rate effect in continuous X-ray diffraction data acquisition at room temperature are presented. The first study of room-temperature macromolecular crystallography data acquisition with a silicon pixel detector is presented, where the data are collected in continuous sample rotation mode, with millisecond read-out time and no read-out noise. Several successive datasets were collected sequentially from single test crystals of thaumatin and insulin. The dose rate ranged between ∼1320 Gy s{sup −1} and ∼8420 Gy s{sup −1} with corresponding frame rates between 1.565 Hz and 12.5 Hz. The data were analysed for global radiation damage. A previously unreported negative dose-rate effect is observed in the indicators of global radiation damage, which showed an approximately 75% decrease in D{sub 1/2} at sixfold higher dose rate. The integrated intensity decreases in an exponential manner. Sample heating that could give rise to the enhanced radiation sensitivity at higher dose rate is investigated by collecting data between crystal temperatures of 298 K and 353 K. UV-Vis spectroscopy is used to demonstrate that disulfide radicals and trapped electrons do not accumulate at high dose rates in continuous data collection.

  19. Multiplexed phase-space imaging for 3D fluorescence microscopy.

    Science.gov (United States)

    Liu, Hsiou-Yuan; Zhong, Jingshan; Waller, Laura

    2017-06-26

    Optical phase-space functions describe spatial and angular information simultaneously; examples of optical phase-space functions include light fields in ray optics and Wigner functions in wave optics. Measurement of phase-space enables digital refocusing, aberration removal and 3D reconstruction. High-resolution capture of 4D phase-space datasets is, however, challenging. Previous scanning approaches are slow, light inefficient and do not achieve diffraction-limited resolution. Here, we propose a multiplexed method that solves these problems. We use a spatial light modulator (SLM) in the pupil plane of a microscope in order to sequentially pattern multiplexed coded apertures while capturing images in real space. Then, we reconstruct the 3D fluorescence distribution of our sample by solving an inverse problem via regularized least squares with a proximal accelerated gradient descent solver. We experimentally reconstruct a 101 Megavoxel 3D volume (1010×510×500µm with NA 0.4), demonstrating improved acquisition time, light throughput and resolution compared to scanning aperture methods. Our flexible patterning scheme further allows sparsity in the sample to be exploited for reduced data capture.

  20. Sequential learning in individuals with agrammatic aphasia: evidence from artificial grammar learning.

    Science.gov (United States)

    Schuchard, Julia; Thompson, Cynthia K

    2017-01-01

    We examined sequential learning in individuals with agrammatic aphasia ( n = 12) and healthy age-matched participants ( n = 12) using an artificial grammar. Artificial grammar acquisition, 24-hour retention, and the potential benefits of additional training were examined by administering an artificial grammar judgment test (1) immediately following auditory exposure-based training, (2) one day after training, and (3) after a second training session on the second day. An untrained control group ( n = 12 healthy age-matched participants) completed the tests on the same time schedule. The trained healthy and aphasic groups showed greater sensitivity to the detection of grammatical items than the control group. No significant correlations between sequential learning and language abilities were observed among the aphasic participants. The results suggest that individuals with agrammatic aphasia show sequential learning, but the underlying processes involved in this learning may be different than for healthy adults.

  1. Calorimetric thermal-vacuum performance characterization of the BAe 80K space cryocooler

    International Nuclear Information System (INIS)

    Kotsubo, V.Y.; Johnson, D.L.; Ross, R.G. Jr.

    1992-01-01

    This paper on a comprehensive characterization program which is underway at JPL to generate test data on long-life, miniature Stirling-cycle cryocoolers for space application. The key focus of this paper is on the thermal performance of the British Aerospace (BAe) 80K split-Stirling-cycle cryocooler as measured in a unique calorimetric thermal-vacuum test chamber that accurately simulates the heat-transfer interfaces of space. Two separate cooling fluid loops provide precis individual control of the compressor and displacer heatsink temperatures. In addition, heatflow transducers enable calorimetric measurements of the heat rejected separately by the compressor and displacer. Cooler thermal performance has been mapped for coldtip temperatures ranging from below 45 K to above 150 K, for heat-sink temperatures ranging from 280 K to 320 K, and for a wide variety of operational variables including compressor-displacer phase, compressor-displacer stoke, drive frequency, and piston-displacer dc offset

  2. Measurement of $C\\!P$ violation in the phase space of $B^{\\pm} \\to K^{\\pm} \\pi^{+} \\pi^{-}$ and $B^{\\pm} \\to K^{\\pm} K^{+} K^{-}$ decays

    CERN Document Server

    INSPIRE-00258707; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves Jr, A A; Amato, S; Amerio, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Andrews, J E; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Baalouch, M; Bachmann, S; Back, J J; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bauer, Th; Bay, A; Beddow, J; Bedeschi, F; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M -O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Burducea, I; Bursche, A; Busetto, G; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Castillo Garcia, L; Cattaneo, M; Cauet, Ch; Cenci, R; Charles, M; Charpentier, Ph; Chen, P; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Couturier, B; Cowan, G A; Craik, D C; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; Davis, A; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Del Buono, L; Déléage, N; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Di Ruscio, F; Dijkstra, H; Dogaru, M; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Elsby, D; Falabella, A; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Giubega, L; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Griffith, P; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hamilton, B; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Hartmann, T; He, J; Head, T; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicheur, A; Hicks, E; Hill, D; Hoballah, M; Holtrop, M; Hombach, C; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jans, E; Jaton, P; Jawahery, A; Jing, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Kaballo, M; Kandybei, S; Kanso, W; Karacson, M; Karbach, T M; Kenyon, I R; Ketel, T; Keune, A; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J -P; Lefèvre, R; Leflat, A; Lefrançois, J; Leo, S; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lohn, S; Longstaff, I; Lopes, J H; Lopez-March, N; Lu, H; Lucchesi, D; Luisier, J; Luo, H; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Maurice, E; Mazurov, A; Mc Skelly, B; McCarthy, J; McNab, A; McNulty, R; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M -N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mordà, A; Morello, M J; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neubert, S; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pal, B K; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, A; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Roberts, D A; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rouvinet, J; Ruf, T; Ruffini, F; Ruiz, H; Ruiz Valls, P; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salustino Guimaraes, V; Salzmann, C; Sanmartin Sedes, B; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Sirendi, M; Skwarnicki, T; Smith, N A; Smith, E; Smith, J; Smith, M; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Sun, L; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urner, D; Ustyuzhanin, A; Uwer, U; Vagnoni, V; Valenti, G; Vallier, A; Van Dijk, M; Vazquez Gomez, R; Vazquez Regueiro, P; Vázquez Sierra, C; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, C; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiechczynski, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wimberley, J; Wishahi, J; Witek, M; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, Z; Yang, Z; Young, R; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2013-01-01

    The charmless decays $B^{\\pm}\\to K^{\\pm}\\pi^+\\pi^-$ and $B^{\\pm}\\to K^{\\pm}K^+K^-$ are reconstructed using data, corresponding to an integrated luminosity of 1.0 fb$^{-1}$, collected by LHCb in 2011. The inclusive charge asymmetries of these modes are measured as $A_{C\\!P}(B^{\\pm}\\to K^{\\pm}\\pi^+\\pi^-) = 0.032 \\pm 0.008 {\\mathrm{\\,(stat)}} \\pm 0.004 {\\mathrm{\\,(syst)}} \\pm 0.007 (J/\\psi K^{\\pm})$ and $A_{C\\!P}(B^{\\pm}\\to K^{\\pm}K^+K^-) = -0.043 \\pm 0.009 {\\mathrm{\\,(stat)}} \\pm 0.003 {\\mathrm{\\,(syst)}} \\pm 0.007 (J/\\psi K^{\\pm})$, where the third uncertainty is due to the $C\\!P$ asymmetry of the $B^{\\pm}\\to J/\\psi K^{\\pm}$ reference mode. The significance of $A_{C\\!P}(B^{\\pm}\\to K^{\\pm}K^+K^-)$ exceeds three standard deviations and is the first evidence of an inclusive $C\\!P$ asymmetry in charmless three-body $B$ decays. In addition to the inclusive $C\\!P$ asymmetries, larger asymmetries are observed in localised regions of phase space.

  3. Review of the Joint Capability Integration and Development System (JCIDS) and the National Security Space Acquisition Process (NSSAP)

    National Research Council Canada - National Science Library

    Gamache, Joyce A

    2006-01-01

    ...) and the National Security Space Acquisition Process (NSSAP) through a qualitative case study. The author identifies ways to improve this interaction by answering investigative questions and providing recommendations to be tested in future research.

  4. A Bayesian Theory of Sequential Causal Learning and Abstract Transfer.

    Science.gov (United States)

    Lu, Hongjing; Rojas, Randall R; Beckers, Tom; Yuille, Alan L

    2016-03-01

    Two key research issues in the field of causal learning are how people acquire causal knowledge when observing data that are presented sequentially, and the level of abstraction at which learning takes place. Does sequential causal learning solely involve the acquisition of specific cause-effect links, or do learners also acquire knowledge about abstract causal constraints? Recent empirical studies have revealed that experience with one set of causal cues can dramatically alter subsequent learning and performance with entirely different cues, suggesting that learning involves abstract transfer, and such transfer effects involve sequential presentation of distinct sets of causal cues. It has been demonstrated that pre-training (or even post-training) can modulate classic causal learning phenomena such as forward and backward blocking. To account for these effects, we propose a Bayesian theory of sequential causal learning. The theory assumes that humans are able to consider and use several alternative causal generative models, each instantiating a different causal integration rule. Model selection is used to decide which integration rule to use in a given learning environment in order to infer causal knowledge from sequential data. Detailed computer simulations demonstrate that humans rely on the abstract characteristics of outcome variables (e.g., binary vs. continuous) to select a causal integration rule, which in turn alters causal learning in a variety of blocking and overshadowing paradigms. When the nature of the outcome variable is ambiguous, humans select the model that yields the best fit with the recent environment, and then apply it to subsequent learning tasks. Based on sequential patterns of cue-outcome co-occurrence, the theory can account for a range of phenomena in sequential causal learning, including various blocking effects, primacy effects in some experimental conditions, and apparently abstract transfer of causal knowledge. Copyright © 2015

  5. Magnetic resonance imaging acquisition techniques intended to decrease movement artefact in paediatric brain imaging: a systematic review

    International Nuclear Information System (INIS)

    Woodfield, Julie; Kealey, Susan

    2015-01-01

    Attaining paediatric brain images of diagnostic quality can be difficult because of young age or neurological impairment. The use of anaesthesia to reduce movement in MRI increases clinical risk and cost, while CT, though faster, exposes children to potentially harmful ionising radiation. MRI acquisition techniques that aim to decrease movement artefact may allow diagnostic paediatric brain imaging without sedation or anaesthesia. We conducted a systematic review to establish the evidence base for ultra-fast sequences and sequences using oversampling of k-space in paediatric brain MR imaging. Techniques were assessed for imaging time, occurrence of movement artefact, the need for sedation, and either image quality or diagnostic accuracy. We identified 24 relevant studies. We found that ultra-fast techniques had shorter imaging acquisition times compared to standard MRI. Techniques using oversampling of k-space required equal or longer imaging times than standard MRI. Both ultra-fast sequences and those using oversampling of k-space reduced movement artefact compared with standard MRI in unsedated children. Assessment of overall diagnostic accuracy was difficult because of the heterogeneous patient populations, imaging indications, and reporting methods of the studies. In children with shunt-treated hydrocephalus there is evidence that ultra-fast MRI is sufficient for the assessment of ventricular size. (orig.)

  6. Magnetic resonance imaging acquisition techniques intended to decrease movement artefact in paediatric brain imaging: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Woodfield, Julie [University of Edinburgh, Child Life and Health, Edinburgh (United Kingdom); Kealey, Susan [Western General Hospital, Department of Neuroradiology, Edinburgh (United Kingdom)

    2015-08-15

    Attaining paediatric brain images of diagnostic quality can be difficult because of young age or neurological impairment. The use of anaesthesia to reduce movement in MRI increases clinical risk and cost, while CT, though faster, exposes children to potentially harmful ionising radiation. MRI acquisition techniques that aim to decrease movement artefact may allow diagnostic paediatric brain imaging without sedation or anaesthesia. We conducted a systematic review to establish the evidence base for ultra-fast sequences and sequences using oversampling of k-space in paediatric brain MR imaging. Techniques were assessed for imaging time, occurrence of movement artefact, the need for sedation, and either image quality or diagnostic accuracy. We identified 24 relevant studies. We found that ultra-fast techniques had shorter imaging acquisition times compared to standard MRI. Techniques using oversampling of k-space required equal or longer imaging times than standard MRI. Both ultra-fast sequences and those using oversampling of k-space reduced movement artefact compared with standard MRI in unsedated children. Assessment of overall diagnostic accuracy was difficult because of the heterogeneous patient populations, imaging indications, and reporting methods of the studies. In children with shunt-treated hydrocephalus there is evidence that ultra-fast MRI is sufficient for the assessment of ventricular size. (orig.)

  7. Online sequential condition prediction method of natural circulation systems based on EOS-ELM and phase space reconstruction

    International Nuclear Information System (INIS)

    Chen, Hanying; Gao, Puzhen; Tan, Sichao; Tang, Jiguo; Yuan, Hongsheng

    2017-01-01

    Highlights: •An online condition prediction method for natural circulation systems in NPP was proposed based on EOS-ELM. •The proposed online prediction method was validated using experimental data. •The training speed of the proposed method is significantly fast. •The proposed method can achieve good accuracy in wide parameter range. -- Abstract: Natural circulation design is widely used in the passive safety systems of advanced nuclear power reactors. The irregular and chaotic flow oscillations are often observed in boiling natural circulation systems so it is difficult for operators to monitor and predict the condition of these systems. An online condition forecasting method for natural circulation system is proposed in this study as an assisting technique for plant operators. The proposed prediction approach was developed based on Ensemble of Online Sequential Extreme Learning Machine (EOS-ELM) and phase space reconstruction. Online Sequential Extreme Learning Machine (OS-ELM) is an online sequential learning neural network algorithm and EOS-ELM is the ensemble method of it. The proposed condition prediction method can be initiated by a small chunk of monitoring data and it can be updated by newly arrived data at very fast speed during the online prediction. Simulation experiments were conducted on the data of two natural circulation loops to validate the performance of the proposed method. The simulation results show that the proposed predication model can successfully recognize different types of flow oscillations and accurately forecast the trend of monitored plant variables. The influence of the number of hidden nodes and neural network inputs on prediction performance was studied and the proposed model can achieve good accuracy in a wide parameter range. Moreover, the comparison results show that the proposed condition prediction method has much faster online learning speed and better prediction accuracy than conventional neural network model.

  8. Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction

    Science.gov (United States)

    Hollingsworth, Kieren Grant

    2015-11-01

    MRI is often the most sensitive or appropriate technique for important measurements in clinical diagnosis and research, but lengthy acquisition times limit its use due to cost and considerations of patient comfort and compliance. Once an image field of view and resolution is chosen, the minimum scan acquisition time is normally fixed by the amount of raw data that must be acquired to meet the Nyquist criteria. Recently, there has been research interest in using the theory of compressed sensing (CS) in MR imaging to reduce scan acquisition times. The theory argues that if our target MR image is sparse, having signal information in only a small proportion of pixels (like an angiogram), or if the image can be mathematically transformed to be sparse then it is possible to use that sparsity to recover a high definition image from substantially less acquired data. This review starts by considering methods of k-space undersampling which have already been incorporated into routine clinical imaging (partial Fourier imaging and parallel imaging), and then explains the basis of using compressed sensing in MRI. The practical considerations of applying CS to MRI acquisitions are discussed, such as designing k-space undersampling schemes, optimizing adjustable parameters in reconstructions and exploiting the power of combined compressed sensing and parallel imaging (CS-PI). A selection of clinical applications that have used CS and CS-PI prospectively are considered. The review concludes by signposting other imaging acceleration techniques under present development before concluding with a consideration of the potential impact and obstacles to bringing compressed sensing into routine use in clinical MRI.

  9. Ultrasound Vector Flow Imaging: Part I: Sequential Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav Ivanov; Yu, Alfred C. H.

    2016-01-01

    , and variants of these. The review covers both 2-D and 3-D velocity estimation and gives a historical perspective on the development along with a summary of various vector flow visualization algorithms. The current state-of-the-art is explained along with an overview of clinical studies conducted and methods......The paper gives a review of the most important methods for blood velocity vector flow imaging (VFI) for conventional, sequential data acquisition. This includes multibeam methods, speckle tracking, transverse oscillation, color flow mapping derived vector flow imaging, directional beamforming...

  10. The Role of Orthotactic Probability in Incidental and Intentional Vocabulary Acquisition L1 and L2

    Science.gov (United States)

    Bordag, Denisa; Kirschenbaum, Amit; Rogahn, Maria; Tschirner, Erwin

    2017-01-01

    Four experiments were conducted to examine the role of orthotactic probability, i.e. the sequential letter probability, in the early stages of vocabulary acquisition by adult native speakers and advanced learners of German. The results show different effects for orthographic probability in incidental and intentional vocabulary acquisition: Whereas…

  11. STEP: Self-supporting tailored k-space estimation for parallel imaging reconstruction.

    Science.gov (United States)

    Zhou, Zechen; Wang, Jinnan; Balu, Niranjan; Li, Rui; Yuan, Chun

    2016-02-01

    A new subspace-based iterative reconstruction method, termed Self-supporting Tailored k-space Estimation for Parallel imaging reconstruction (STEP), is presented and evaluated in comparison to the existing autocalibrating method SPIRiT and calibrationless method SAKE. In STEP, two tailored schemes including k-space partition and basis selection are proposed to promote spatially variant signal subspace and incorporated into a self-supporting structured low rank model to enforce properties of locality, sparsity, and rank deficiency, which can be formulated into a constrained optimization problem and solved by an iterative algorithm. Simulated and in vivo datasets were used to investigate the performance of STEP in terms of overall image quality and detail structure preservation. The advantage of STEP on image quality is demonstrated by retrospectively undersampled multichannel Cartesian data with various patterns. Compared with SPIRiT and SAKE, STEP can provide more accurate reconstruction images with less residual aliasing artifacts and reduced noise amplification in simulation and in vivo experiments. In addition, STEP has the capability of combining compressed sensing with arbitrary sampling trajectory. Using k-space partition and basis selection can further improve the performance of parallel imaging reconstruction with or without calibration signals. © 2015 Wiley Periodicals, Inc.

  12. Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection.

    Science.gov (United States)

    O'Halloran, Rafael L; Holmes, James H; Wu, Yu-Chien; Alexander, Andrew; Fain, Sean B

    2010-01-01

    An undersampled diffusion-weighted stack-of-stars acquisition is combined with iterative highly constrained back-projection to perform hyperpolarized helium-3 MR q-space imaging with combined regional correction of radiofrequency- and T1-related signal loss in a single breath-held scan. The technique is tested in computer simulations and phantom experiments and demonstrated in a healthy human volunteer with whole-lung coverage in a 13-sec breath-hold. Measures of lung microstructure at three different lung volumes are evaluated using inhaled gas volumes of 500 mL, 1000 mL, and 1500 mL to demonstrate feasibility. Phantom results demonstrate that the proposed technique is in agreement with theoretical values, as well as with a fully sampled two-dimensional Cartesian acquisition. Results from the volunteer study demonstrate that the root mean squared diffusion distance increased significantly from the 500-mL volume to the 1000-mL volume. This technique represents the first demonstration of a spatially resolved hyperpolarized helium-3 q-space imaging technique and shows promise for microstructural evaluation of lung disease in three dimensions. Copyright (c) 2009 Wiley-Liss, Inc.

  13. Trade study for kWe class space reactors

    Science.gov (United States)

    Bost, Donald S.

    Recent interest by NASA and other government agencies in space reactor power systems with power levels in the 1 to 100 kWe range has prompted a review of earlier space reactor programs, as well as the ongoing SP-100 program, to identify a system that will best fulfill their needs. The candidate reactor types that were reviewed are listed. They are categorized according to the method of heat removal. The five types are: conduction cooled, heat pipe cooled, liquid metal cooled, in-core thermionic and gas cooled. The UZrH moderated reactor coupled with an organic Rankine cycle power conversion system provides an attractive system for multikilowatt, long lived missions. The reactor requires a minimum development because a similar reactor has already flown and the ORC is being developed for use in the Dynamic Isotope Power System (DIPS) and on the Space Station.

  14. A Cross-Cultural Validation of the Sequential-Simultaneous Theory of Intelligence in Children.

    Science.gov (United States)

    Moon, Soo-Back; McLean, James E.; Kaufman, Alan S.

    2003-01-01

    The Kaufman Assessment Battery for Children - Korean (K-ABC-K) was developed to assess the intelligence and achievement of preschool and school-aged Korean children. This study examined the validity of the Sequential Processing, Simultaneous Processing and Achievement scales of the K-ABC-K. The factor analyses provided strong support for the…

  15. Sequential Triangle Strip Generator based on Hopfield Networks

    Czech Academy of Sciences Publication Activity Database

    Šíma, Jiří; Lněnička, Radim

    2009-01-01

    Roč. 21, č. 2 (2009), s. 583-617 ISSN 0899-7667 R&D Projects: GA MŠk(CZ) 1M0545; GA AV ČR 1ET100300517; GA MŠk 1M0572 Institutional research plan: CEZ:AV0Z10300504; CEZ:AV0Z10750506 Keywords : sequential triangle strip * combinatorial optimization * Hopfield network * minimum energy * simulated annealing Subject RIV: IN - Informatics, Computer Science Impact factor: 2.175, year: 2009

  16. Space-time relationship in continuously moving table method for large FOV peripheral contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Sabati, M; Lauzon, M L; Frayne, R

    2003-01-01

    Data acquisition using a continuously moving table approach is a method capable of generating large field-of-view (FOV) 3D MR angiograms. However, in order to obtain venous contamination-free contrast-enhanced (CE) MR angiograms in the lower limbs, one of the major challenges is to acquire all necessary k-space data during the restricted arterial phase of the contrast agent. Preliminary investigation on the space-time relationship of continuously acquired peripheral angiography is performed in this work. Deterministic and stochastic undersampled hybrid-space (x, k y , k z ) acquisitions are simulated for large FOV peripheral runoff studies. Initial results show the possibility of acquiring isotropic large FOV images of the entire peripheral vascular system. An optimal trade-off between the spatial and temporal sampling properties was found that produced a high-spatial resolution peripheral CE-MR angiogram. The deterministic sampling pattern was capable of reconstructing the global structure of the peripheral arterial tree and showed slightly better global quantitative results than stochastic patterns. Optimal stochastic sampling patterns, on the other hand, enhanced small vessels and had more favourable local quantitative results. These simulations demonstrate the complex spatial-temporal relationship when sampling large FOV peripheral runoff studies. They also suggest that more investigation is required to maximize image quality as a function of hybrid-space coverage, acquisition repetition time and sampling pattern parameters

  17. Acoustical source reconstruction from non-synchronous sequential measurements by Fast Iterative Shrinkage Thresholding Algorithm

    Science.gov (United States)

    Yu, Liang; Antoni, Jerome; Leclere, Quentin; Jiang, Weikang

    2017-11-01

    Acoustical source reconstruction is a typical inverse problem, whose minimum frequency of reconstruction hinges on the size of the array and maximum frequency depends on the spacing distance between the microphones. For the sake of enlarging the frequency of reconstruction and reducing the cost of an acquisition system, Cyclic Projection (CP), a method of sequential measurements without reference, was recently investigated (JSV,2016,372:31-49). In this paper, the Propagation based Fast Iterative Shrinkage Thresholding Algorithm (Propagation-FISTA) is introduced, which improves CP in two aspects: (1) the number of acoustic sources is no longer needed and the only making assumption is that of a "weakly sparse" eigenvalue spectrum; (2) the construction of the spatial basis is much easier and adaptive to practical scenarios of acoustical measurements benefiting from the introduction of propagation based spatial basis. The proposed Propagation-FISTA is first investigated with different simulations and experimental setups and is next illustrated with an industrial case.

  18. Altered Na+ transport after an intracellular alpha-subunit deletion reveals strict external sequential release of Na+ from the Na/K pump.

    Science.gov (United States)

    Yaragatupalli, Siddhartha; Olivera, J Fernando; Gatto, Craig; Artigas, Pablo

    2009-09-08

    The Na/K pump actively exports 3 Na(+) in exchange for 2 K(+) across the plasmalemma of animal cells. As in other P-type ATPases, pump function is more effective when the relative affinity for transported ions is altered as the ion binding sites alternate between opposite sides of the membrane. Deletion of the five C-terminal residues from the alpha-subunit diminishes internal Na(+) (Na(i)(+)) affinity approximately 25-fold [Morth et al. (2007) Nature 450:1043-1049]. Because external Na(+) (Na(o)(+)) binding is voltage-dependent, we studied the reactions involving this process by using two-electrode and inside-out patch voltage clamp in normal and truncated (DeltaKESYY) Xenopus-alpha1 pumps expressed in oocytes. We observed that DeltaKESYY (i) decreased both Na(o)(+) and Na(i)(+) apparent affinities in the absence of K(o)(+), and (ii) did not affect apparent Na(o)(+) affinity at high K(o)(+). These results support a model of strict sequential external release of Na(+) ions, where the Na(+)-exclusive site releases Na(+) before the sites shared with K(+) and the DeltaKESYY deletion only reduces Na(o)(+) affinity at the shared sites. Moreover, at nonsaturating K(o)(+), DeltaKESYY induced an inward flow of Na(+) through Na/K pumps at negative potentials. Guanidinium(+) can also permeate truncated pumps, whereas N-methyl-D-glucamine cannot. Because guanidinium(o)(+) can also traverse normal Na/K pumps in the absence of both Na(o)(+) and K(o)(+) and can also inhibit Na/K pump currents in a Na(+)-like voltage-dependent manner, we conclude that the normal pathway transited by the first externally released Na(+) is large enough to accommodate guanidinium(+).

  19. Children's Acquisition of Literary Genre: Science Fiction versus Fantasy.

    Science.gov (United States)

    Shechter, Myriam; Schecter, Sandra R.

    Using ethnographic observations of 30 children in a multicultural inner-city fifth grade class over a period of one year, a study examined the children's classroom interactions with the literary genres of science fiction and fantasy, investigating their sequential acquisition of the constitutive elements of the two genres as well as their…

  20. Comparison of rate one-half, equivalent constraint length 24, binary convolutional codes for use with sequential decoding on the deep-space channel

    Science.gov (United States)

    Massey, J. L.

    1976-01-01

    Virtually all previously-suggested rate 1/2 binary convolutional codes with KE = 24 are compared. Their distance properties are given; and their performance, both in computation and in error probability, with sequential decoding on the deep-space channel is determined by simulation. Recommendations are made both for the choice of a specific KE = 24 code as well as for codes to be included in future coding standards for the deep-space channel. A new result given in this report is a method for determining the statistical significance of error probability data when the error probability is so small that it is not feasible to perform enough decoding simulations to obtain more than a very small number of decoding errors.

  1. Sequential determination of important ecotoxic radionuclides in nuclear waste samples

    International Nuclear Information System (INIS)

    Bilohuscin, J.

    2016-01-01

    In the dissertation thesis we focused on the development and optimization of a sequential determination method for radionuclides 93 Zr, 94 Nb, 99 Tc and 126 Sn, employing extraction chromatography sorbents TEVA (R) Resin and Anion Exchange Resin, supplied by Eichrom Industries. Prior to the attestation of sequential separation of these proposed radionuclides from radioactive waste samples, a unique sequential procedure of 90 Sr, 239 Pu, 241 Am separation from urine matrices was tried, using molecular recognition sorbents of AnaLig (R) series and extraction chromatography sorbent DGA (R) Resin. On these experiments, four various sorbents were continually used for separation, including PreFilter Resin sorbent, which removes interfering organic materials present in raw urine. After the acquisition of positive results of this sequential procedure followed experiments with a 126 Sn separation using TEVA (R) Resin and Anion Exchange Resin sorbents. Radiochemical recoveries obtained from samples of radioactive evaporate concentrates and sludge showed high efficiency of the separation, while values of 126 Sn were under the minimum detectable activities MDA. Activity of 126 Sn was determined after ingrowth of daughter nuclide 126m Sb on HPGe gamma detector, with minimal contamination of gamma interfering radionuclides with decontamination factors (D f ) higher then 1400 for 60 Co and 47000 for 137 Cs. Based on the acquired experiments and results of these separation procedures, a complex method of sequential separation of 93 Zr, 94 Nb, 99 Tc and 126 Sn was proposed, which included optimization steps similar to those used in previous parts of the dissertation work. Application of the sequential separation method for sorbents TEVA (R) Resin and Anion Exchange Resin on real samples of radioactive wastes provided satisfactory results and an economical, time sparing, efficient method. (author)

  2. Y-Ba-Cu-O superconducting thin films by simultaneous or sequential evaporation

    International Nuclear Information System (INIS)

    Mogro-Campero, A.; Hunt, B.D.; Turner, L.G.; Burrell, M.C.; Balz, W.E.

    1988-01-01

    Superconducting thin films of Y-Ba-Cu-O near the 1:2:3 stoichiometry were produced by simultaneous (coevaporation) and sequential (multilayer) evaporation in the same evaporator. The best film obtained on yttria-stabilized zirconia (YSZ) had a superconducting onset temperature of 104 K, a midpoint T/sub c/ of 92 K, and zero resistance at T≤74 K. Stoichiometry was deduced by inductively coupled plasma emission spectroscopy, and elemental depth profiles were obtained by x-ray photoelectron spectroscopy. Film stoichiometry changes only near the film/substrate boundary for films on YSZ. Films on Si/SiO 2 were not superconducting; depth profiling shows severe changes of film composition with depth. A major theme of this work is process reproducibility, which was found to be poor for coevaporation but improved considerably for sequential evaporation

  3. The Role of Semantic Transfer in Clitic Drop among Simultaneous and Sequential Chinese-Spanish Bilinguals

    Science.gov (United States)

    Cuza, Alejandro; Perez-Leroux, Ana Teresa; Sanchez, Liliana

    2013-01-01

    This study examines the acquisition of the featural constraints on clitic and null distribution in Spanish among simultaneous and sequential Chinese-Spanish bilinguals from Peru. A truth value judgment task targeted the referential meaning of null objects in a negation context. Objects were elicited via two clitic elicitation tasks that targeted…

  4. CRISPR-spacer integration reporter plasmids reveal distinct genuine acquisition specificities among CRISPR-Cas I-E variants of Escherichia coli.

    Science.gov (United States)

    Díez-Villaseñor, César; Guzmán, Noemí M; Almendros, Cristóbal; García-Martínez, Jesús; Mojica, Francisco J M

    2013-05-01

    Prokaryotes immunize themselves against transmissible genetic elements by the integration (acquisition) in clustered regularly interspaced short palindromic repeats (CRISPR) loci of spacers homologous to invader nucleic acids, defined as protospacers. Following acquisition, mono-spacer CRISPR RNAs (termed crRNAs) guide CRISPR-associated (Cas) proteins to degrade (interference) protospacers flanked by an adjacent motif in extrachomosomal DNA. During acquisition, selection of spacer-precursors adjoining the protospacer motif and proper orientation of the integrated fragment with respect to the leader (sequence leading transcription of the flanking CRISPR array) grant efficient interference by at least some CRISPR-Cas systems. This adaptive stage of the CRISPR action is poorly characterized, mainly due to the lack of appropriate genetic strategies to address its study and, at least in Escherichia coli, the need of Cas overproduction for insertion detection. In this work, we describe the development and application in Escherichia coli strains of an interference-independent assay based on engineered selectable CRISPR-spacer integration reporter plasmids. By using this tool without the constraint of interference or cas overexpression, we confirmed fundamental aspects of this process such as the critical requirement of Cas1 and Cas2 and the identity of the CTT protospacer motif for the E. coli K12 system. In addition, we defined the CWT motif for a non-K12 CRISPR-Cas variant, and obtained data supporting the implication of the leader in spacer orientation, the preferred acquisition from plasmids harboring cas genes and the occurrence of a sequential cleavage at the insertion site by a ruler mechanism.

  5. CRISPR-spacer integration reporter plasmids reveal distinct genuine acquisition specificities among CRISPR-Cas I-E variants of Escherichia coli

    Science.gov (United States)

    Díez-Villaseñor, César; Guzmán, Noemí M.; Almendros, Cristóbal; García-Martínez, Jesús; Mojica, Francisco J.M.

    2013-01-01

    Prokaryotes immunize themselves against transmissible genetic elements by the integration (acquisition) in clustered regularly interspaced short palindromic repeats (CRISPR) loci of spacers homologous to invader nucleic acids, defined as protospacers. Following acquisition, mono-spacer CRISPR RNAs (termed crRNAs) guide CRISPR-associated (Cas) proteins to degrade (interference) protospacers flanked by an adjacent motif in extrachomosomal DNA. During acquisition, selection of spacer-precursors adjoining the protospacer motif and proper orientation of the integrated fragment with respect to the leader (sequence leading transcription of the flanking CRISPR array) grant efficient interference by at least some CRISPR-Cas systems. This adaptive stage of the CRISPR action is poorly characterized, mainly due to the lack of appropriate genetic strategies to address its study and, at least in Escherichia coli, the need of Cas overproduction for insertion detection. In this work, we describe the development and application in Escherichia coli strains of an interference-independent assay based on engineered selectable CRISPR-spacer integration reporter plasmids. By using this tool without the constraint of interference or cas overexpression, we confirmed fundamental aspects of this process such as the critical requirement of Cas1 and Cas2 and the identity of the CTT protospacer motif for the E. coli K12 system. In addition, we defined the CWT motif for a non-K12 CRISPR-Cas variant, and obtained data supporting the implication of the leader in spacer orientation, the preferred acquisition from plasmids harboring cas genes and the occurrence of a sequential cleavage at the insertion site by a ruler mechanism. PMID:23445770

  6. Space Acquisitions: Challenges Facing DOD as it Changes Approaches to Space Acquisitions

    Science.gov (United States)

    2016-03-09

    alternatives to support decisions about the future of space programs, there are gaps in cost and other data needed to weigh the pros and cons of changes to...preliminary work suggests there are gaps in cost and other data needed to weigh the pros and cons of changes to space systems. Second, most changes...Facebook, Flickr, Twitter, and YouTube . Subscribe to our RSS Feeds or E-mail Updates. Listen to our Podcasts and read The Watchblog. Visit GAO on the

  7. Evolutionary Acquisition and Spiral Development Tutorial

    National Research Council Canada - National Science Library

    Hantos, P

    2005-01-01

    .... NSS Acquisition Policy 03-01 provided some space-oriented customization and, similarly to the original DOD directives, also positioned Evolutionary Acquisition and Spiral Development as preferred...

  8. Operation of a Data Acquisition, Transfer, and Storage System for the Global Space-Weather Observation Network

    Directory of Open Access Journals (Sweden)

    T Nagatsuma

    2014-10-01

    Full Text Available A system to optimize the management of global space-weather observation networks has been developed by the National Institute of Information and Communications Technology (NICT. Named the WONM (Wide-area Observation Network Monitoring system, it enables data acquisition, transfer, and storage through connection to the NICT Science Cloud, and has been supplied to observatories for supporting space-weather forecast and research. This system provides us with easier management of data collection than our previously employed systems by means of autonomous system recovery, periodical state monitoring, and dynamic warning procedures. Operation of the WONM system is introduced in this report.

  9. Three Approaches to Space Systems Acquisitions and their Application to the Defense Department’s Weather Satellite Program

    Science.gov (United States)

    2012-03-01

    by Toyota in the manufacturing world, such as just-in-time, kaizen, one-piece flow, jidoka, and heijunka . These techniques helped spawn the “lean...Level out the workload ( heijunka ). (Work like the tortoise, not the hare.) Historically Space Acquisitions have struggled with this principle

  10. Development and verification of a compact TDC-based data acquisition system for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Losekamm, Martin [Physics Department E18, Technische Universitaet Muenchen (Germany); Institute of Astronautics, Technische Universitaet Muenchen (Germany); Gaisbauer, Dominic; Konorov, Igor; Paul, Stephan; Poeschl, Thomas [Physics Department E18, Technische Universitaet Muenchen (Germany)

    2015-07-01

    The advances of solid-state detectors and in particular those for the detection of photons have made their application in space systems increasingly attractive in recent years. The use of, for example, silicon photomultipliers (SiPM) paired with a suitable scintillating material allows the development of compact and lightweight particle detectors. The Antiproton Flux in Space experiment (AFIS) intends to measure the flux of antiprotons trapped in Earth's magnetosphere aboard a nanosatellite using an active target tracking detector, consisting of plastic scintillating fibers read out by SiPMs. In order to implement a large number of detector channels while adhering to the given space, mass and power constraints, the development of a compact TDC-based data acquisition system was proposed. This talk presents a current prototype featuring 900 channels, real-time multi-channel temperature measurement and bias regulation. Possible alternative applications as well as the next steps in the development are also discussed.

  11. Event-shape analysis: Sequential versus simultaneous multifragment emission

    International Nuclear Information System (INIS)

    Cebra, D.A.; Howden, S.; Karn, J.; Nadasen, A.; Ogilvie, C.A.; Vander Molen, A.; Westfall, G.D.; Wilson, W.K.; Winfield, J.S.; Norbeck, E.

    1990-01-01

    The Michigan State University 4π array has been used to select central-impact-parameter events from the reaction 40 Ar+ 51 V at incident energies from 35 to 85 MeV/nucleon. The event shape in momentum space is an observable which is shown to be sensitive to the dynamics of the fragmentation process. A comparison of the experimental event-shape distribution to sequential- and simultaneous-decay predictions suggests that a transition in the breakup process may have occurred. At 35 MeV/nucleon, a sequential-decay simulation reproduces the data. For the higher energies, the experimental distributions fall between the two contrasting predictions

  12. Multiplicity distributions and multiplicity correlations in sequential, off-equilibrium fragmentation process

    International Nuclear Information System (INIS)

    Botet, R.

    1996-01-01

    A new kinetic fragmentation model, the Fragmentation - Inactivation -Binary (FIB) model is described where a dissipative process stops randomly the sequential, conservative and off-equilibrium fragmentation process. (K.A.)

  13. Parallel magnetic resonance imaging as approximation in a reproducing kernel Hilbert space

    International Nuclear Information System (INIS)

    Athalye, Vivek; Lustig, Michael; Martin Uecker

    2015-01-01

    In magnetic resonance imaging data samples are collected in the spatial frequency domain (k-space), typically by time-consuming line-by-line scanning on a Cartesian grid. Scans can be accelerated by simultaneous acquisition of data using multiple receivers (parallel imaging), and by using more efficient non-Cartesian sampling schemes. To understand and design k-space sampling patterns, a theoretical framework is needed to analyze how well arbitrary sampling patterns reconstruct unsampled k-space using receive coil information. As shown here, reconstruction from samples at arbitrary locations can be understood as approximation of vector-valued functions from the acquired samples and formulated using a reproducing kernel Hilbert space with a matrix-valued kernel defined by the spatial sensitivities of the receive coils. This establishes a formal connection between approximation theory and parallel imaging. Theoretical tools from approximation theory can then be used to understand reconstruction in k-space and to extend the analysis of the effects of samples selection beyond the traditional image-domain g-factor noise analysis to both noise amplification and approximation errors in k-space. This is demonstrated with numerical examples. (paper)

  14. The integration of automated knowledge acquisition with computer-aided software engineering for space shuttle expert systems

    Science.gov (United States)

    Modesitt, Kenneth L.

    1990-01-01

    A prediction was made that the terms expert systems and knowledge acquisition would begin to disappear over the next several years. This is not because they are falling into disuse; it is rather that practitioners are realizing that they are valuable adjuncts to software engineering, in terms of problem domains addressed, user acceptance, and in development methodologies. A specific problem was discussed, that of constructing an automated test analysis system for the Space Shuttle Main Engine. In this domain, knowledge acquisition was part of requirements systems analysis, and was performed with the aid of a powerful inductive ESBT in conjunction with a computer aided software engineering (CASE) tool. The original prediction is not a very risky one -- it has already been accomplished.

  15. Evaluation of Reduced Power Spectra from Three-Dimensional k-Space

    Science.gov (United States)

    Saur, J.; von Papen, M.

    2014-12-01

    We present a new tool to evaluate one dimensional reduced power spectral densities (PSD) from arbitrary energy distributions in kk-space. This enables us to calculate the power spectra as they are measured in spacecraft frame for any given measurement geometry assuming Taylor's frozen-in approximation. It is possible to seperately calculate the diagonal elements of the spectral tensor and also to insert additional, non-turbulent energy in kk-space (e.g. mirror mode waves). Given a critically balanced turbulent cascade with k∥˜kα⊥k_\\|sim k_perp^alpha, we explore the implications on the spectral form of the PSD and the functional dependence of the spectral index κkappa on the field-to-flow angle θtheta between plasma flow and background magnetic field. We show that critically balanced turbulence develops a θtheta-independent cascade with the spectral slope of the perpendicular cascade κ(θ=90∘)kappa(theta{=}90^circ). This happens at frequencies f>fmaxf>f_mathrm{max}, where fmax(L,α,θ)f_mathrm{max}(L,alpha,theta) is a function of outer scale LL, critical balance exponent αalpha and field-to-flow angle θtheta. We also discuss potential damping terms acting on the kk-space distribution of energy and their effect on the PSD. Further, we show that the functional dependence κ(θ)kappa(theta) as found by textit{Horbury et al.} (2008) and textit{Chen et al.} (2010) can be explained with a damped critically balanced turbulence model.

  16. The k-space origins of scattering in Bi2Sr2CaCu2O8+x.

    Science.gov (United States)

    Alldredge, Jacob W; Calleja, Eduardo M; Dai, Jixia; Eisaki, H; Uchida, S; McElroy, Kyle

    2013-08-21

    We demonstrate a general, computer automated procedure that inverts the reciprocal space scattering data (q-space) that are measured by spectroscopic imaging scanning tunnelling microscopy (SI-STM) in order to determine the momentum space (k-space) scattering structure. This allows a detailed examination of the k-space origins of the quasiparticle interference (QPI) pattern in Bi2Sr2CaCu2O8+x within the theoretical constraints of the joint density of states (JDOS). Our new method allows measurement of the differences between the positive and negative energy dispersions, the gap structure and an energy dependent scattering length scale. Furthermore, it resolves the transition between the dispersive QPI and the checkerboard ([Formula: see text] excitation). We have measured the k-space scattering structure over a wide range of doping (p ∼ 0.22-0.08), including regions where the octet model is not applicable. Our technique allows the complete mapping of the k-space scattering origins of the spatial excitations in Bi2Sr2CaCu2O8+x, which allows for better comparisons between SI-STM and other experimental probes of the band structure. By applying our new technique to such a heavily studied compound, we can validate our new general approach for determining the k-space scattering origins from SI-STM data.

  17. The composite sequential clustering technique for analysis of multispectral scanner data

    Science.gov (United States)

    Su, M. Y.

    1972-01-01

    The clustering technique consists of two parts: (1) a sequential statistical clustering which is essentially a sequential variance analysis, and (2) a generalized K-means clustering. In this composite clustering technique, the output of (1) is a set of initial clusters which are input to (2) for further improvement by an iterative scheme. This unsupervised composite technique was employed for automatic classification of two sets of remote multispectral earth resource observations. The classification accuracy by the unsupervised technique is found to be comparable to that by traditional supervised maximum likelihood classification techniques. The mathematical algorithms for the composite sequential clustering program and a detailed computer program description with job setup are given.

  18. Sequential and Simultaneous Processing in Children with Learning Disabilities: An Attempted Replication.

    Science.gov (United States)

    Bain, Sherry K.

    1993-01-01

    Analysis of Kaufman Assessment Battery for Children (K-ABC) Sequential and Simultaneous Processing scores of 94 children (ages 6-12) with learning disabilities produced factor patterns generally supportive of the traditional K-ABC Mental Processing structure with the exception of Spatial Memory. The sample exhibited relative processing strengths…

  19. MO-FG-CAMPUS-IeP1-01: Alternative K-Edge Filters for Low-Energy Image Acquisition in Contrast Enhanced Spectral Mammography

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, S; Vedantham, S; Karellas, A [University of Massachusetts Medical School, Worcester, MA (United States)

    2016-06-15

    Purpose: In Contrast Enhanced Spectral Mammography (CESM), Rh filter is often used during low-energy image acquisition. The potential for using Ag, In and Sn filters, which exhibit K-edge closer to, and just below that of Iodine, instead of the Rh filter, was investigated for the low-energy image acquisition. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for 50µm Rh were compared with other potential K-edge filters (Ag, In and Sn), all with K-absorption edge below that of Iodine. Two strategies were investigated: fixed kVp and filter thickness (50µm for all filters) resulting in HVT variation, and fixed kVp and HVT resulting in variation in Ag, In and Sn thickness. Monte Carlo simulations (GEANT4) were conducted to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Rh and other K-edge filters. Results: Ag, In and Sn filters (50µm thick) increased photon fluence/mAs by 1.3–1.4, 1.8–2, and 1.7–2 at 28-32 kVp compared to 50µm Rh, which could decrease exposure time. Additionally, the fraction of spectra closer to and just below Iodine’s K-edge increased with these filters, which could improve post-subtraction image contrast. For HVT matched to 50µm Rh filtered spectra, the thickness range for Ag, In, and Sn were (41,44)µm, (49,55)µm and (45,53)µm, and increased photon fluence/mAs by 1.5–1.7, 1.6–2, and 1.6–2.2, respectively. Monte Carlo simulations showed that neither the SPR nor the scatter PSF of Ag, In and Sn differed from Rh, indicating no additional detriment due to x-ray scatter. Conclusion: The use of Ag, In and Sn filters for low-energy image acquisition in CESM is potentially feasible and could decrease exposure time and may improve post-subtraction image contrast. Effect of these filters on radiation dose, contrast, noise and associated metrics are being investigated. Funding Support: Supported in

  20. Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

    Science.gov (United States)

    Trott, C M; Ouyang, J; El Fakhri, G

    2010-11-21

    Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest (99m)Tc-sestamibi/(123)I-BMIPP imaging protocol in place of the commonly used sequential rest/stress (99m)Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.

  1. Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects

    International Nuclear Information System (INIS)

    Trott, C M; Ouyang, J; El Fakhri, G

    2010-01-01

    Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two radionuclide signals. We consider a simultaneous rest 99m Tc-sestamibi/ 123 I-BMIPP imaging protocol in place of the commonly used sequential rest/stress 99m Tc-sestamibi protocol. The theoretical precision with which the severity of a cardiac defect and the transmural extent of infarct can be measured is computed for simultaneous and sequential SPECT imaging, and their performance is compared for discriminating (1) degrees of defect severity and (2) sub-endocardial from transmural defects. We consider cardiac infarcts for which reduced perfusion and metabolism are observed. From an information perspective, simultaneous imaging is found to yield comparable or improved performance compared with sequential imaging for discriminating both severity of defect and transmural extent of infarct, for three defects of differing location and size.

  2. A fast and efficient method for sequential cone-beam tomography

    International Nuclear Information System (INIS)

    Koehler, Th.; Proksa, R.; Grass, M.

    2001-01-01

    Sequential cone-beam tomography is a method that uses data of two or more parallel circular trajectories of a cone-beam scanner to reconstruct the object function. We propose a condition for the data acquisition that ensures that all object points between two successive circles are irradiated over an angular span of the x-ray source position of exactly 360 deg. in total as seen along the rotation axis. A fast and efficient approximative reconstruction method for the proposed acquisition is presented which uses data from exactly 360 deg. for every object point. It is based on the Tent-FDK method which was recently developed for single circular cone-beam CT. The measurement geometry does not provide sufficient data for exact reconstruction but it is shown that the proposed reconstruction method provides satisfying image quality for small cone angles

  3. Glycerol production by Oenococcus oeni during sequential and simultaneous cultures with wine yeast strains.

    Science.gov (United States)

    Ale, Cesar E; Farías, Marta E; Strasser de Saad, Ana M; Pasteris, Sergio E

    2014-07-01

    Growth and fermentation patterns of Saccharomyces cerevisiae, Kloeckera apiculata, and Oenococcus oeni strains cultured in grape juice medium were studied. In pure, sequential and simultaneous cultures, the strains reached the stationary growth phase between 2 and 3 days. Pure and mixed K. apiculata and S. cerevisiae cultures used mainly glucose, producing ethanol, organic acids, and 4.0 and 0.1 mM glycerol, respectively. In sequential cultures, O. oeni achieved about 1 log unit at 3 days using mainly fructose and L-malic acid. Highest sugars consumption was detected in K. apiculata supernatants, lactic acid being the major end-product. 8.0 mM glycerol was found in 6-day culture supernatants. In simultaneous cultures, total sugars and L-malic acid were used at 3 days and 98% of ethanol and glycerol were detected. This study represents the first report of the population dynamics and metabolic behavior of yeasts and O. oeni in sequential and simultaneous cultures and contributes to the selection of indigenous strains to design starter cultures for winemaking, also considering the inclusion of K. apiculata. The sequential inoculation of yeasts and O. oeni would enhance glycerol production, which confers desirable organoleptic characteristics to wines, while organic acids levels would not affect their sensory profile. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Wavelet transform of generalized functions in K ′{Mp} spaces

    Indian Academy of Sciences (India)

    Using convolution theory in K{Mp} space we obtain bounded results for the wavelet transform. Calderón-type reproducing formula is derived in distribution sense as an application of the same. An inversion formula for the wavelet transform of generalized functions is established. Keywords. Continuous wavelet transform ...

  5. Mean-Variance-Validation Technique for Sequential Kriging Metamodels

    International Nuclear Information System (INIS)

    Lee, Tae Hee; Kim, Ho Sung

    2010-01-01

    The rigorous validation of the accuracy of metamodels is an important topic in research on metamodel techniques. Although a leave-k-out cross-validation technique involves a considerably high computational cost, it cannot be used to measure the fidelity of metamodels. Recently, the mean 0 validation technique has been proposed to quantitatively determine the accuracy of metamodels. However, the use of mean 0 validation criterion may lead to premature termination of a sampling process even if the kriging model is inaccurate. In this study, we propose a new validation technique based on the mean and variance of the response evaluated when sequential sampling method, such as maximum entropy sampling, is used. The proposed validation technique is more efficient and accurate than the leave-k-out cross-validation technique, because instead of performing numerical integration, the kriging model is explicitly integrated to accurately evaluate the mean and variance of the response evaluated. The error in the proposed validation technique resembles a root mean squared error, thus it can be used to determine a stop criterion for sequential sampling of metamodels

  6. Data acquisition system in TPE-1RM15

    International Nuclear Information System (INIS)

    Yagi, Yasuyuki; Yahagi, Eiichi; Hirano, Yoichi; Shimada, Toshio; Hirota, Isao; Maejima, Yoshiki

    1991-01-01

    The data acquisition system for TPE-1RM15 reversed field pinch machine had been developed and has recently been completed. Thd data to be acquired consist of many channels of time series data which come from plasma diagnostics. The newly developed data acquisition system uses CAMAC (Computer Automated Measurement And Control) system as a front end data acquisition system and micro-VAX II for control, file management and analyses. Special computer programs, DAQR/D, have been developed for data acquisition routine. Experimental setting and process controlling items are managed by a parameter database in a shared common region and every task can easily refer to it. The acquired data are stored into a mass storage system (total of 1.3GBytes plus a magnetic tape system) including an optical disk system, which can save storage space and allow quick reference. At present, the CAMAC system has 88 (1MHz sampling) and 64(5kHz sampling) channels corresponding to 1.6 MBytes per shot. The data acquisition system can finish one routine within 5 minutes with 1.6MBytes data depending on the amount of graphic outputs. Hardwares and softwares of the system are specified so that the system can be easily expanded. The computer is connected to the AIST Ethernet and the system can be remotely accessed and the acquired data can be transferred to the mainframes on the network. Details about specifications and performance of the system are given in this report. (author)

  7. 48 CFR 1825.1101 - Acquisition of supplies.

    Science.gov (United States)

    2010-10-01

    ....225-8, Duty-Free Entry of Space Articles, in solicitations and contracts when the supplies that will... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Acquisition of supplies... ADMINISTRATION SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Solicitation Provisions and Contract Clauses 1825.1101...

  8. Correlation between k-space sampling pattern and MTF in compressed sensing MRSI.

    Science.gov (United States)

    Heikal, A A; Wachowicz, K; Fallone, B G

    2016-10-01

    To investigate the relationship between the k-space sampling patterns used for compressed sensing MR spectroscopic imaging (CS-MRSI) and the modulation transfer function (MTF) of the metabolite maps. This relationship may allow the desired frequency content of the metabolite maps to be quantitatively tailored when designing an undersampling pattern. Simulations of a phantom were used to calculate the MTF of Nyquist sampled (NS) 32 × 32 MRSI, and four-times undersampled CS-MRSI reconstructions. The dependence of the CS-MTF on the k-space sampling pattern was evaluated for three sets of k-space sampling patterns generated using different probability distribution functions (PDFs). CS-MTFs were also evaluated for three more sets of patterns generated using a modified algorithm where the sampling ratios are constrained to adhere to PDFs. Strong visual correlation as well as high R 2 was found between the MTF of CS-MRSI and the product of the frequency-dependant sampling ratio and the NS 32 × 32 MTF. Also, PDF-constrained sampling patterns led to higher reproducibility of the CS-MTF, and stronger correlations to the above-mentioned product. The relationship established in this work provides the user with a theoretical solution for the MTF of CS MRSI that is both predictable and customizable to the user's needs.

  9. Recursion method in the k-space representation

    International Nuclear Information System (INIS)

    Anlage, S.M.; Smith, D.L.

    1986-01-01

    We show that by using a unitary transformation to k space and the special-k-point method for evaluating Brillouin-zone sums, the recursion method can be very effectively applied to translationally invariant systems. We use this approach to perform recursion calculations for realistic tight-binding Hamiltonians which describe diamond- and zinc-blende-structure semiconductors. Projected densities of states for these Hamiltonians have band gaps and internal van Hove singularities. We calculate coefficients for 63 recursion levels exactly and for about 200 recursion levels to a good approximation. Comparisons are made for materials with different magnitude band gaps (diamond, Si, α-Sn). Comparison is also made between materials with one (e.g., diamond) and two (e.g., GaAs) band gaps. The asymptotic behavior of the recursion coefficients is studied by Fourier analysis. Band gaps in the projected density of states dominate the asymptotic behavior. Perturbation analysis describes the asymptotic behavior rather well. Projected densities of states are calculated using a very simple termination scheme. These densities of states compare favorably with the results of Gilat-Raubenheimer integration

  10. Design of a Mechanical NaK Pump for Fission Space Power

    Science.gov (United States)

    Mireles, Omar R.; Bradley, David E.; Godfroy, Thomas

    2011-01-01

    Alkali liquid metal cooled fission reactor concepts are under development for spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid, which has specific pumping requirements. Traditionally, electromagnetic linear induction pumps have been used to provide the required flow and pressure head conditions for NaK systems but they can be limited in performance, efficiency, and number of available vendors. The objective of the project was to develop a mechanical NaK centrifugal pump that takes advantages of technology advances not available in previous liquid metal mechanical pump designs. This paper details the design, build, and performance test of a mechanical NaK pump developed at NASA Marshall Space Flight Center. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

  11. Radiation damage in room-temperature data acquisition with the PILATUS 6M pixel detector.

    Science.gov (United States)

    Rajendran, Chitra; Dworkowski, Florian S N; Wang, Meitian; Schulze-Briese, Clemens

    2011-05-01

    The first study of room-temperature macromolecular crystallography data acquisition with a silicon pixel detector is presented, where the data are collected in continuous sample rotation mode, with millisecond read-out time and no read-out noise. Several successive datasets were collected sequentially from single test crystals of thaumatin and insulin. The dose rate ranged between ∼ 1320 Gy s(-1) and ∼ 8420 Gy s(-1) with corresponding frame rates between 1.565 Hz and 12.5 Hz. The data were analysed for global radiation damage. A previously unreported negative dose-rate effect is observed in the indicators of global radiation damage, which showed an approximately 75% decrease in D(1/2) at sixfold higher dose rate. The integrated intensity decreases in an exponential manner. Sample heating that could give rise to the enhanced radiation sensitivity at higher dose rate is investigated by collecting data between crystal temperatures of 298 K and 353 K. UV-Vis spectroscopy is used to demonstrate that disulfide radicals and trapped electrons do not accumulate at high dose rates in continuous data collection.

  12. A sequential hypothesis test based on a generalized Azuma inequality

    NARCIS (Netherlands)

    Reijsbergen, D.P.; Scheinhardt, Willem R.W.; de Boer, Pieter-Tjerk

    We present a new power-one sequential hypothesis test based on a bound for the probability that a bounded zero-mean martingale ever crosses a curve of the form $a(n+k)^b$. The proof of the bound is of independent interest.

  13. Estimation of Outage Capacity for Free Space Optical Links Over I-K and K Turbulent Channels

    Directory of Open Access Journals (Sweden)

    D. Marinos

    2011-06-01

    Full Text Available The free space optical communication systems are attracting great research and commercial interest due to their capability of transferring data, over short distances, with high rate and security, low cost demands and without licensing fees. However, their performance depends strongly on the atmospheric conditions in the link’s area. In this work, we investigate the influence of the turbulence on the outage capacity of such a system for weak to strong turbulence channels modeled by the I-K and the K-distribution and we derive closed-form expressions for its estimation. Finally, using these expressions we present numerical results for various link cases with different turbulence conditions.

  14. A Bayesian sequential processor approach to spectroscopic portal system decisions

    Energy Technology Data Exchange (ETDEWEB)

    Sale, K; Candy, J; Breitfeller, E; Guidry, B; Manatt, D; Gosnell, T; Chambers, D

    2007-07-31

    The development of faster more reliable techniques to detect radioactive contraband in a portal type scenario is an extremely important problem especially in this era of constant terrorist threats. Towards this goal the development of a model-based, Bayesian sequential data processor for the detection problem is discussed. In the sequential processor each datum (detector energy deposit and pulse arrival time) is used to update the posterior probability distribution over the space of model parameters. The nature of the sequential processor approach is that a detection is produced as soon as it is statistically justified by the data rather than waiting for a fixed counting interval before any analysis is performed. In this paper the Bayesian model-based approach, physics and signal processing models and decision functions are discussed along with the first results of our research.

  15. A novel method for the sequential removal and separation of multiple heavy metals from wastewater.

    Science.gov (United States)

    Fang, Li; Li, Liang; Qu, Zan; Xu, Haomiao; Xu, Jianfang; Yan, Naiqiang

    2018-01-15

    A novel method was developed and applied for the treatment of simulated wastewater containing multiple heavy metals. A sorbent of ZnS nanocrystals (NCs) was synthesized and showed extraordinary performance for the removal of Hg 2+ , Cu 2+ , Pb 2+ and Cd 2+ . The removal efficiencies of Hg 2+ , Cu 2+ , Pb 2+ and Cd 2+ were 99.9%, 99.9%, 90.8% and 66.3%, respectively. Meanwhile, it was determined that solubility product (K sp ) of heavy metal sulfides was closely related to adsorption selectivity of various heavy metals on the sorbent. The removal efficiency of Hg 2+ was higher than that of Cd 2+ , while the K sp of HgS was lower than that of CdS. It indicated that preferential adsorption of heavy metals occurred when the K sp of the heavy metal sulfide was lower. In addition, the differences in the K sp of heavy metal sulfides allowed for the exchange of heavy metals, indicating the potential application for the sequential removal and separation of heavy metals from wastewater. According to the cumulative adsorption experimental results, multiple heavy metals were sequentially adsorbed and separated from the simulated wastewater in the order of the K sp of their sulfides. This method holds the promise of sequentially removing and separating multiple heavy metals from wastewater. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Multiple and sequential data acquisition method: an improved method for fragmentation and detection of cross-linked peptides on a hybrid linear trap quadrupole Orbitrap Velos mass spectrometer.

    Science.gov (United States)

    Rudashevskaya, Elena L; Breitwieser, Florian P; Huber, Marie L; Colinge, Jacques; Müller, André C; Bennett, Keiryn L

    2013-02-05

    The identification and validation of cross-linked peptides by mass spectrometry remains a daunting challenge for protein-protein cross-linking approaches when investigating protein interactions. This includes the fragmentation of cross-linked peptides in the mass spectrometer per se and following database searching, the matching of the molecular masses of the fragment ions to the correct cross-linked peptides. The hybrid linear trap quadrupole (LTQ) Orbitrap Velos combines the speed of the tandem mass spectrometry (MS/MS) duty circle with high mass accuracy, and these features were utilized in the current study to substantially improve the confidence in the identification of cross-linked peptides. An MS/MS method termed multiple and sequential data acquisition method (MSDAM) was developed. Preliminary optimization of the MS/MS settings was performed with a synthetic peptide (TP1) cross-linked with bis[sulfosuccinimidyl] suberate (BS(3)). On the basis of these results, MSDAM was created and assessed on the BS(3)-cross-linked bovine serum albumin (BSA) homodimer. MSDAM applies a series of multiple sequential fragmentation events with a range of different normalized collision energies (NCE) to the same precursor ion. The combination of a series of NCE enabled a considerable improvement in the quality of the fragmentation spectra for cross-linked peptides, and ultimately aided in the identification of the sequences of the cross-linked peptides. Concurrently, MSDAM provides confirmatory evidence from the formation of reporter ions fragments, which reduces the false positive rate of incorrectly assigned cross-linked peptides.

  17. A node linkage approach for sequential pattern mining.

    Directory of Open Access Journals (Sweden)

    Osvaldo Navarro

    Full Text Available Sequential Pattern Mining is a widely addressed problem in data mining, with applications such as analyzing Web usage, examining purchase behavior, and text mining, among others. Nevertheless, with the dramatic increase in data volume, the current approaches prove inefficient when dealing with large input datasets, a large number of different symbols and low minimum supports. In this paper, we propose a new sequential pattern mining algorithm, which follows a pattern-growth scheme to discover sequential patterns. Unlike most pattern growth algorithms, our approach does not build a data structure to represent the input dataset, but instead accesses the required sequences through pseudo-projection databases, achieving better runtime and reducing memory requirements. Our algorithm traverses the search space in a depth-first fashion and only preserves in memory a pattern node linkage and the pseudo-projections required for the branch being explored at the time. Experimental results show that our new approach, the Node Linkage Depth-First Traversal algorithm (NLDFT, has better performance and scalability in comparison with state of the art algorithms.

  18. War-gaming application for future space systems acquisition: MATLAB implementation of war-gaming acquisition models and simulation results

    Science.gov (United States)

    Vienhage, Paul; Barcomb, Heather; Marshall, Karel; Black, William A.; Coons, Amanda; Tran, Hien T.; Nguyen, Tien M.; Guillen, Andy T.; Yoh, James; Kizer, Justin; Rogers, Blake A.

    2017-05-01

    The paper describes the MATLAB (MathWorks) programs that were developed during the REU workshop1 to implement The Aerospace Corporation developed Unified Game-based Acquisition Framework and Advanced Game - based Mathematical Framework (UGAF-AGMF) and its associated War-Gaming Engine (WGE) models. Each game can be played from the perspectives of the Department of Defense Acquisition Authority (DAA) or of an individual contractor (KTR). The programs also implement Aerospace's optimum "Program and Technical Baseline (PTB) and associated acquisition" strategy that combines low Total Ownership Cost (TOC) with innovative designs while still meeting warfighter needs. The paper also describes the Bayesian Acquisition War-Gaming approach using Monte Carlo simulations, a numerical analysis technique to account for uncertainty in decision making, which simulate the PTB development and acquisition processes and will detail the procedure of the implementation and the interactions between the games.

  19. Research on parallel algorithm for sequential pattern mining

    Science.gov (United States)

    Zhou, Lijuan; Qin, Bai; Wang, Yu; Hao, Zhongxiao

    2008-03-01

    Sequential pattern mining is the mining of frequent sequences related to time or other orders from the sequence database. Its initial motivation is to discover the laws of customer purchasing in a time section by finding the frequent sequences. In recent years, sequential pattern mining has become an important direction of data mining, and its application field has not been confined to the business database and has extended to new data sources such as Web and advanced science fields such as DNA analysis. The data of sequential pattern mining has characteristics as follows: mass data amount and distributed storage. Most existing sequential pattern mining algorithms haven't considered the above-mentioned characteristics synthetically. According to the traits mentioned above and combining the parallel theory, this paper puts forward a new distributed parallel algorithm SPP(Sequential Pattern Parallel). The algorithm abides by the principal of pattern reduction and utilizes the divide-and-conquer strategy for parallelization. The first parallel task is to construct frequent item sets applying frequent concept and search space partition theory and the second task is to structure frequent sequences using the depth-first search method at each processor. The algorithm only needs to access the database twice and doesn't generate the candidated sequences, which abates the access time and improves the mining efficiency. Based on the random data generation procedure and different information structure designed, this paper simulated the SPP algorithm in a concrete parallel environment and implemented the AprioriAll algorithm. The experiments demonstrate that compared with AprioriAll, the SPP algorithm had excellent speedup factor and efficiency.

  20. Lunar and Planetary Science XXXV: Engaging K-12 Educators, Students, and the General Public in Space Science Exploration

    Science.gov (United States)

    2004-01-01

    The session "Engaging K-12 Educators, Students, and the General Public in Space Science Exploration" included the following reports:Training Informal Educators Provides Leverage for Space Science Education and Public Outreach; Teacher Leaders in Research Based Science Education: K-12 Teacher Retention, Renewal, and Involvement in Professional Science; Telling the Tale of Two Deserts: Teacher Training and Utilization of a New Standards-based, Bilingual E/PO Product; Lindstrom M. M. Tobola K. W. Stocco K. Henry M. Allen J. S. McReynolds J. Porter T. T. Veile J. Space Rocks Tell Their Secrets: Space Science Applications of Physics and Chemistry for High School and College Classes -- Update; Utilizing Mars Data in Education: Delivering Standards-based Content by Exposing Educators and Students to Authentic Scientific Opportunities and Curriculum; K. E. Little Elementary School and the Young Astronaut Robotics Program; Integrated Solar System Exploration Education and Public Outreach: Theme, Products and Activities; and Online Access to the NEAR Image Collection: A Resource for Educators and Scientists.

  1. Sequential neural models with stochastic layers

    DEFF Research Database (Denmark)

    Fraccaro, Marco; Sønderby, Søren Kaae; Paquet, Ulrich

    2016-01-01

    How can we efficiently propagate uncertainty in a latent state representation with recurrent neural networks? This paper introduces stochastic recurrent neural networks which glue a deterministic recurrent neural network and a state space model together to form a stochastic and sequential neural...... generative model. The clear separation of deterministic and stochastic layers allows a structured variational inference network to track the factorization of the model's posterior distribution. By retaining both the nonlinear recursive structure of a recurrent neural network and averaging over...

  2. Lexical decoder for continuous speech recognition: sequential neural network approach

    International Nuclear Information System (INIS)

    Iooss, Christine

    1991-01-01

    The work presented in this dissertation concerns the study of a connectionist architecture to treat sequential inputs. In this context, the model proposed by J.L. Elman, a recurrent multilayers network, is used. Its abilities and its limits are evaluated. Modifications are done in order to treat erroneous or noisy sequential inputs and to classify patterns. The application context of this study concerns the realisation of a lexical decoder for analytical multi-speakers continuous speech recognition. Lexical decoding is completed from lattices of phonemes which are obtained after an acoustic-phonetic decoding stage relying on a K Nearest Neighbors search technique. Test are done on sentences formed from a lexicon of 20 words. The results are obtained show the ability of the proposed connectionist model to take into account the sequentiality at the input level, to memorize the context and to treat noisy or erroneous inputs. (author) [fr

  3. Test of PPV and kVp magnitudes using a non invasive voltage test aiming an improvement on the measurement acquisition

    International Nuclear Information System (INIS)

    Lucena, Rodrigo F. de; Dias, Daniel M.; Franciscatto, Priscila C.; Correa, Eduardo de L.; Vivolo, Vitor; Potiens, Maria da Penha A.

    2009-01-01

    In this work the measurements of PPV (Practical Peak Voltage) and kVp (Peak Voltage) were studied obtained by use of voltage non invasive, under different conditions, viewing an improvement on the acquisition measurements at the Instrument Calibration Laboratory of the IPEN, Sao Paulo, Brazil, for the implantation of the radiation quality required for the required calibrations for X radiation instruments

  4. Sequential Power-Dependence Theory

    NARCIS (Netherlands)

    Buskens, Vincent; Rijt, Arnout van de

    2008-01-01

    Existing methods for predicting resource divisions in laboratory exchange networks do not take into account the sequential nature of the experimental setting. We extend network exchange theory by considering sequential exchange. We prove that Sequential Power-Dependence Theory—unlike

  5. Sequential Monte Carlo with Highly Informative Observations

    OpenAIRE

    Del Moral, Pierre; Murray, Lawrence M.

    2014-01-01

    We propose sequential Monte Carlo (SMC) methods for sampling the posterior distribution of state-space models under highly informative observation regimes, a situation in which standard SMC methods can perform poorly. A special case is simulating bridges between given initial and final values. The basic idea is to introduce a schedule of intermediate weighting and resampling times between observation times, which guide particles towards the final state. This can always be done for continuous-...

  6. On the origin of reproducible sequential activity in neural circuits

    Science.gov (United States)

    Afraimovich, V. S.; Zhigulin, V. P.; Rabinovich, M. I.

    2004-12-01

    Robustness and reproducibility of sequential spatio-temporal responses is an essential feature of many neural circuits in sensory and motor systems of animals. The most common mathematical images of dynamical regimes in neural systems are fixed points, limit cycles, chaotic attractors, and continuous attractors (attractive manifolds of neutrally stable fixed points). These are not suitable for the description of reproducible transient sequential neural dynamics. In this paper we present the concept of a stable heteroclinic sequence (SHS), which is not an attractor. SHS opens the way for understanding and modeling of transient sequential activity in neural circuits. We show that this new mathematical object can be used to describe robust and reproducible sequential neural dynamics. Using the framework of a generalized high-dimensional Lotka-Volterra model, that describes the dynamics of firing rates in an inhibitory network, we present analytical results on the existence of the SHS in the phase space of the network. With the help of numerical simulations we confirm its robustness in presence of noise in spite of the transient nature of the corresponding trajectories. Finally, by referring to several recent neurobiological experiments, we discuss possible applications of this new concept to several problems in neuroscience.

  7. Human Robotic Systems (HRS): Robotic ISRU Acquisition Element

    Data.gov (United States)

    National Aeronautics and Space Administration — During 2014, the Robotic ISRU Resource Acquisition project element will develop two technologies:Exploration Ground Data Systems (xGDS)Sample Acquisition on...

  8. Development and Testing of a Variable Conductance Thermal Acquisition, Transport, and Switching System

    Science.gov (United States)

    Bugby, David C.; Farmer, Jeffery T.; Stouffer, Charles J.

    2013-01-01

    This paper describes the development and testing of a scalable thermal management architecture for instruments, subsystems, or systems that must operate in severe space environments with wide variations in sink temperature. The architecture involves a serial linkage of one or more hot-side variable conductance heat pipes (VCHPs) to one or more cold-side loop heat pipes (LHPs). The VCHPs provide wide area heat acquisition, limited distance thermal transport, modest against gravity pumping, concentrated LHP startup heating, and high switching ratio variable conductance operation. The LHPs provide localized heat acquisition, long distance thermal transport, significant against gravity pumping, and high switching ratio variable conductance operation. The single-VCHP, single-LHP system described herein was developed to maintain thermal control of a small robotic lunar lander throughout the lunar day-night thermal cycle. It is also applicable to other variable heat rejection space missions in severe environments. Operationally, despite a 60-70% gas blocked VCHP condenser during ON testing, the system was still able to provide 2-4 W/K ON conductance, 0.01 W/K OFF conductance, and an end-to-end switching ratio of 200-400. The paper provides a detailed analysis of VCHP condenser performance, which quantified the gas blockage situation. Future multi-VCHP/multi-LHP thermal management system concepts that provide power/transport length scalability are also discussed.

  9. Influence of defects on the effective electrical conductivity of a monolayer produced by random sequential adsorption of linear k-mers onto a square lattice

    Science.gov (United States)

    Tarasevich, Yuri Yu.; Laptev, Valeri V.; Goltseva, Valeria A.; Lebovka, Nikolai I.

    2017-07-01

    The effect of defects on the behaviour of electrical conductivity, σ, in a monolayer produced by the random sequential adsorption of linear k-mers (particles occupying k adjacent sites) onto a square lattice is studied by means of a Monte Carlo simulation. The k-mers are deposited on the substrate until a jamming state is reached. The presence of defects in the lattice (impurities) and of defects in the k-mers with concentrations of dl and dk, respectively, is assumed. The defects in the lattice are distributed randomly before deposition and these lattice sites are forbidden for the deposition of k-mers. The defects of the k-mers are distributed randomly on the deposited k-mers. The sites filled with k-mers have high electrical conductivity, σk, whereas the empty sites, and the sites filled by either types of defect have a low electrical conductivity, σl, i.e., a high-contrast, σk /σl ≫ 1, is assumed. We examined isotropic (both the possible x and y orientations of a particle are equiprobable) and anisotropic (all particles are aligned along one given direction, y) deposition. To calculate the effective electrical conductivity, the monolayer was presented as a random resistor network and the Frank-Lobb algorithm was used. The effects of the concentrations of defects dl and dk on the electrical conductivity for the values of k =2n, where n = 1 , 2 , … , 5, were studied. Increase of both the dl and dk parameters values resulted in decreases in the value of σ and the suppression of percolation. Moreover, for anisotropic deposition the electrical conductivity along the y direction was noticeably larger than in the perpendicular direction, x. Phase diagrams in the (dl ,dk)-plane for different values of k were obtained.

  10. The ground testing of a 2 kWe solar dynamic space power system

    International Nuclear Information System (INIS)

    Calogeras, J.E.

    1992-01-01

    Over the past 25 years Space Solar Dynamic component development has advanced to the point where it is considered a leading candidate power source technology for the evolutionary phases of the Space Station Freedom (SSF) program. Selection of SD power was based on studies and analyses which indicated significant savings in life cycle costs, launch mass and EVA requirements were possible when the system is compared to more conventional photovoltaic/battery power systems. Issues associated with micro-gravity operation such as the behavior of the thermal energy storage materials are being addressed in other programs. This paper reports that a ground test of a 2 kWe solar dynamic system is being planned by the NASA Office of Aeronautics and Space Technology to address the integration issues. The test will be scalable up to 25 kWe, will be flight configured and will incorporate relevant features of the SSF Solar Dynamic Power Module design

  11. kNOw Fear: Making rural public spaces safer for women and girls ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2018-05-01

    May 1, 2018 ... kNOw Fear: Making rural public spaces safer for women and girls ... The International Centre for Research on Women (ICRW) conducts research ... Poonam Kathuria's 17 years of experience as a women's rights advocate is ...

  12. Group-Sequential Strategies in Clinical Trials with Multiple Co-Primary Outcomes

    Science.gov (United States)

    Hamasaki, Toshimitsu; Asakura, Koko; Evans, Scott R; Sugimoto, Tomoyuki; Sozu, Takashi

    2015-01-01

    We discuss the decision-making frameworks for clinical trials with multiple co-primary endpoints in a group-sequential setting. The decision-making frameworks can account for flexibilities such as a varying number of analyses, equally or unequally spaced increments of information and fixed or adaptive Type I error allocation among endpoints. The frameworks can provide efficiency, i.e., potentially fewer trial participants, than the fixed sample size designs. We investigate the operating characteristics of the decision-making frameworks and provide guidance on constructing efficient group-sequential strategies in clinical trials with multiple co-primary endpoints. PMID:25844122

  13. View-sharing in keyhole imaging: Partially compressed central k-space acquisition in time-resolved MRA at 3.0 T

    International Nuclear Information System (INIS)

    Hadizadeh, Dariusch R.; Gieseke, Juergen; Beck, Gabriele; Geerts, Liesbeth; Kukuk, Guido M.; Bostroem, Azize; Urbach, Horst; Schild, Hans H.; Willinek, Winfried A.

    2011-01-01

    Introduction: Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CEMRA) of the intracranial vasculature has proved its clinical value for the evaluation of cerebral vascular disease in cases where both flow hemodynamics and morphology are important. The purpose of this study was to evaluate a combination of view-sharing with keyhole imaging to increase spatial and temporal resolution of time-resolved CEMRA at 3.0 T. Methods: Alternating view-sharing was combined with randomly segmented k-space ordering, keyhole imaging, partial Fourier and parallel imaging (4DkvsMRA). 4DkvsMRA was evaluated using varying compression factors (80-100) resulting in spatial resolutions ranging from (1.1 x 1.1 x 1.4) to (0.96 x 0.96 x 0.95) mm 3 and temporal resolutions ranging from 586 ms/dynamic scan - 288 ms/dynamic scan in three protocols in 10 healthy volunteers and seven patients (17 subjects). DSA correlation was available in four patients with cerebral arteriovenous malformations (cAVMs) and one patient with cerebral teleangiectasia. Results: 4DkvsMRA was successfully performed in all subjects and showed clear depiction of arterial and venous phases with diagnostic image quality. At the maximum view-sharing compression factor (=100), a 'flickering' artefact was observed. Conclusion: View-sharing in keyhole imaging allows for increased spatial and temporal resolution in time-resolved MRA.

  14. View-sharing in keyhole imaging: Partially compressed central k-space acquisition in time-resolved MRA at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Hadizadeh, Dariusch R., E-mail: Dariusch.Hadizadeh@ukb.uni-bonn.de [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Philips Healthcare, Best (Netherlands); Beck, Gabriele; Geerts, Liesbeth [Philips Healthcare, Best (Netherlands); Kukuk, Guido M. [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Bostroem, Azize [Department of Neurosurgery, Sigmund-Freud-Strasse 25, 53127 Bonn, Deutschland (Germany); Urbach, Horst; Schild, Hans H.; Willinek, Winfried A. [University of Bonn, Department of Radiology, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany)

    2011-11-15

    Introduction: Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CEMRA) of the intracranial vasculature has proved its clinical value for the evaluation of cerebral vascular disease in cases where both flow hemodynamics and morphology are important. The purpose of this study was to evaluate a combination of view-sharing with keyhole imaging to increase spatial and temporal resolution of time-resolved CEMRA at 3.0 T. Methods: Alternating view-sharing was combined with randomly segmented k-space ordering, keyhole imaging, partial Fourier and parallel imaging (4DkvsMRA). 4DkvsMRA was evaluated using varying compression factors (80-100) resulting in spatial resolutions ranging from (1.1 x 1.1 x 1.4) to (0.96 x 0.96 x 0.95) mm{sup 3} and temporal resolutions ranging from 586 ms/dynamic scan - 288 ms/dynamic scan in three protocols in 10 healthy volunteers and seven patients (17 subjects). DSA correlation was available in four patients with cerebral arteriovenous malformations (cAVMs) and one patient with cerebral teleangiectasia. Results: 4DkvsMRA was successfully performed in all subjects and showed clear depiction of arterial and venous phases with diagnostic image quality. At the maximum view-sharing compression factor (=100), a 'flickering' artefact was observed. Conclusion: View-sharing in keyhole imaging allows for increased spatial and temporal resolution in time-resolved MRA.

  15. Support for social rehabilitation of childhood acute lymphoblastic leukemia patients. Psychological and educational assessment by the K-ABC

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, Mayuko [Ochanomizu Univ., Tokyo (Japan); Hosoya, Ryouta; Oohira, Mutsuro; Kaneko, Takashi; Matsushita, Taketsugu

    2000-10-01

    Intellectual impairment in pediatric acute lymphoblastic leukemia (ALL) is thought to be caused by the effect of treatment on the central nervous system. We therefore assessed the characteristics and tendencies of patients' cognitive ability by using the K-ABC (Kaufman Assessment Battery for Children), an intelligence test. The subjects were 28 patients treated for ALL (males 18, females 10, age 4.7-12.0 years). The patients who took the K-ABC test were divided into irradiation group (15 patients who received brain irradiation as prophylactic treatment) and a non-irradiation group (13 patients whose brain was not irradiated), and evaluated the results. The K-ABC consists of a cognition processing scale and an acquisition level, and the cognition processing scale consists of a sequential processing scale and simultaneous processing scale. Patients were assessed in regard to various factors: 1. sex, 2. age of onset, 3. length of hospital stay, 4. age at the time of irradiation, 5. radiation dose, 6. score on the cognition processing scale, and multiple comparisons were made based on analysis of variance, least significant differences (1, 2, 3, 6), and the t-test (4, 5). Sequential processing ability was impaired in the patients with impaired cognitive processing in both groups. Part of simultaneous processing ability (ability to understand spatial relationships) tended to be reduced in the irradiation group in addition to the impairment in sequential processing ability, and factors 1 and 4 influenced cognitive ability in the irradiation group. The ability of girls decreased more than in boys. When children were irradiated below 4 years of age, their ability decreased even more. Regardless of whether they had received radiation therapy, all of the patients had received chemotherapy, including methotrexate, etc., and the anticancer drugs may have reduced their cognitive ability. The reduction of simultaneous processing ability may have been caused by the addition

  16. Support for social rehabilitation of childhood acute lymphoblastic leukemia patients. Psychological and educational assessment by the K-ABC

    International Nuclear Information System (INIS)

    Izumi, Mayuko; Hosoya, Ryouta; Oohira, Mutsuro; Kaneko, Takashi; Matsushita, Taketsugu

    2000-01-01

    Intellectual impairment in pediatric acute lymphoblastic leukemia (ALL) is thought to be caused by the effect of treatment on the central nervous system. We therefore assessed the characteristics and tendencies of patients' cognitive ability by using the K-ABC (Kaufman Assessment Battery for Children), an intelligence test. The subjects were 28 patients treated for ALL (males 18, females 10, age 4.7-12.0 years). The patients who took the K-ABC test were divided into irradiation group (15 patients who received brain irradiation as prophylactic treatment) and a non-irradiation group (13 patients whose brain was not irradiated), and evaluated the results. The K-ABC consists of a cognition processing scale and an acquisition level, and the cognition processing scale consists of a sequential processing scale and simultaneous processing scale. Patients were assessed in regard to various factors: 1. sex, 2. age of onset, 3. length of hospital stay, 4. age at the time of irradiation, 5. radiation dose, 6. score on the cognition processing scale, and multiple comparisons were made based on analysis of variance, least significant differences (1, 2, 3, 6), and the t-test (4, 5). Sequential processing ability was impaired in the patients with impaired cognitive processing in both groups. Part of simultaneous processing ability (ability to understand spatial relationships) tended to be reduced in the irradiation group in addition to the impairment in sequential processing ability, and factors 1 and 4 influenced cognitive ability in the irradiation group. The ability of girls decreased more than in boys. When children were irradiated below 4 years of age, their ability decreased even more. Regardless of whether they had received radiation therapy, all of the patients had received chemotherapy, including methotrexate, etc., and the anticancer drugs may have reduced their cognitive ability. The reduction of simultaneous processing ability may have been caused by the addition of

  17. Forward Modeling of Reduced Power Spectra from Three-dimensional k-space

    Science.gov (United States)

    von Papen, Michael; Saur, Joachim

    2015-06-01

    We present results from a numerical forward model to evaluate one-dimensional reduced power spectral densities (PSDs) from arbitrary energy distributions in {\\boldsymbol{k}} -space. In this model, we can separately calculate the diagonal elements of the spectral tensor for incompressible axisymmetric turbulence with vanishing helicity. Given a critically balanced turbulent cascade with {{k}\\parallel }∼ k\\bot α and α \\lt 1, we explore the implications on the reduced PSD as a function of frequency. The spectra are obtained under the assumption of Taylor’s hypothesis. We further investigate the functional dependence of the spectral index κ on the field-to-flow angle θ between plasma flow and background magnetic field from MHD to electron kinetic scales. We show that critically balanced turbulence asymptotically develops toward θ-independent spectra with a slope corresponding to the perpendicular cascade. This occurs at a transition frequency {{f}2D}(L,α ,θ ), which is analytically estimated and depends on outer scale L, critical balance exponent α, and field-to-flow angle θ. We discuss anisotropic damping terms acting on the {\\boldsymbol{k}} -space distribution of energy and their effects on the PSD. Further, we show that the spectral anisotropies κ (θ ) as found by Horbury et al. and Chen et al. in the solar wind are in accordance with a damped critically balanced cascade of kinetic Alfvén waves. We also model power spectra obtained by Papen et al. in Saturn’s plasma sheet and find that the change of spectral indices inside 9 {{R}s} can be explained by damping on electron scales.

  18. Input and Intake in Language Acquisition

    Science.gov (United States)

    Gagliardi, Ann C.

    2012-01-01

    This dissertation presents an approach for a productive way forward in the study of language acquisition, sealing the rift between claims of an innate linguistic hypothesis space and powerful domain general statistical inference. This approach breaks language acquisition into its component parts, distinguishing the input in the environment from…

  19. Programme for test generation for combinatorial and sequential systems

    International Nuclear Information System (INIS)

    Tran Huy Hoan

    1973-01-01

    This research thesis reports the computer-assisted search for tests aimed at failure detection in combinatorial and sequential logic circuits. As he wants to deal with complex circuits with many modules such as those met in large scale integrated circuits (LSI), the author used propagation paths. He reports the development of a method which is valid for combinatorial systems and for several sequential circuits comprising elementary logic modules and JK and RS flip-flops. This method is developed on an IBM 360/91 computer in PL/1 language. The used memory space is limited and adjustable with respect to circuit dimension. Computing time is short when compared to that needed by other programmes. The solution is practical and efficient for failure test and localisation

  20. Cosmiclike domain walls in superfluid 3He-B: Instantons and diabolical points in (k,r) space

    International Nuclear Information System (INIS)

    Salomaa, M.M.; Volovik, G.E.

    1988-01-01

    The possible planar superfluid B-B boundaries between inequivalent B-phase vacua are considered; such B-B interfaces provide an analogy with the cosmic domain walls that are believed to have precipitated in the phase transitions of the early Universe. Several of them display nontrivial structure in (k,r) space (i.e., the union of the momentum and real spaces). Such a wall represents an instanton connecting two B-phase vacua with different k-space topology. The transition between the vacua occurs through the formation of a pointlike defect either in the (k,r) space, or in the (k,t) space. These defects are so-called diabolical points of codimension 4, at which the fermionic energy tends to zero, thus providing the fermionic zero modes. Such points are new examples (within condensed-matter physics) of the peculiar diabolical points, which are characterized by the occurrence of a contact between the different branches of the quasiparticle spectra; in the present case, the branches of particles and holes, respectively. These points are here discussed for the case of the superfluid phases of liquid 3 He in close analogy with the quantum field theory of fermions interacting with classical bosonic fields. The cosmiclike domain walls in superfluid 3 He-B are observable in principle; in particular, the motion of the superfluid A-B interface is governed at low temperatures by the periodical emission of these topological excitation planes

  1. A 100 kW-Class Technology Demonstrator for Space Solar Power

    Science.gov (United States)

    Howell, J.; Carrington, C.; Day, G.

    2004-12-01

    A first step in the development of solar power from space is the flight demonstration of critical technologies. These fundamental technologies include efficient solar power collection and generation, power management and distribution, and thermal management. In addition, the integration and utilization of these technologies into a viable satellite bus could provide an energy-rich platform for a portfolio of payload experiments such as wireless power transmission (WPT). This paper presents the preliminary design of a concept for a 100 kW-class free-flying platform suitable for flight demonstration of Space Solar Power (SSP) technology experiments.

  2. Defense Acquisition Workforce: The Air Force Needs to Evaluate Changes in Funding for Civilians Engaged in Space Acquisition

    Science.gov (United States)

    2013-07-01

    1) revitalize the acquisition workforce; (2) improve the requirements generation process; (3) instill budget and financial DOD Acquisition...with our four recommended actions (see app . I). In concurring with our recommendations, DOD stated that the Air Force will evaluate the pilot program

  3. Xenon Acquisition Strategies for High-Power Electric Propulsion NASA Missions

    Science.gov (United States)

    Herman, Daniel A.; Unfried, Kenneth G.

    2015-01-01

    The benefits of high-power solar electric propulsion (SEP) for both NASA's human and science exploration missions combined with the technology investment from the Space Technology Mission Directorate have enabled the development of a 50kW-class SEP mission. NASA mission concepts developed, including the Asteroid Redirect Robotic Mission, and those proposed by contracted efforts for the 30kW-class demonstration have a range of xenon propellant loads from 100's of kg up to 10,000 kg. A xenon propellant load of 10 metric tons represents greater than 10% of the global annual production rate of xenon. A single procurement of this size with short-term delivery can disrupt the xenon market, driving up pricing, making the propellant costs for the mission prohibitive. This paper examines the status of the xenon industry worldwide, including historical xenon supply and pricing. The paper discusses approaches for acquiring on the order of 10 MT of xenon propellant considering realistic programmatic constraints to support potential near-term NASA missions. Finally, the paper will discuss acquisitions strategies for mission campaigns utilizing multiple high-power solar electric propulsion vehicles requiring 100's of metric tons of xenon over an extended period of time where a longer term acquisition approach could be implemented.

  4. New 5 kW free-piston Stirling space convertor developments

    Science.gov (United States)

    Brandhorst, Henry W., Jr.; Chapman, Peter A., Jr.

    2008-07-01

    The NASA Vision for Exploration of the moon may someday require a nuclear reactor coupled with a free-piston Stirling convertor at a power level of 30-40 kW. In the 1990s, Mechanical Technology Inc.'s Stirling Engine Systems Division (some of whose Stirling personnel are now at Foster-Miller, Inc.) developed a 25 kW free-piston Stirling Space Power Demonstrator Engine under the SP-100 program. This system consisted of two 12.5 kW engines connected at their hot ends and mounted in tandem to cancel vibration. Recently, NASA and DoE have been developing dual 55 and 80 W Stirling convertor systems for potential use with radioisotope heat sources. Total test times of all convertors in this effort exceed 120,000 h. Recently, NASA began a new project with Auburn University to develop a 5 kW, single convertor for potential use in a lunar surface reactor power system. Goals of this development program include a specific power in excess of 140 W/kg at the convertor level, lifetime in excess of five years and a control system that will safely manage the convertors in case of an emergency. Auburn University awarded a subcontract to Foster-Miller, Inc. to undertake development of the 5 kW Stirling convertor assembly. The characteristics of the design along with progress in developing the system will be described.

  5. Sequential emergence and clinical implications of viral mutants with K70E and K65R mutation in reverse transcriptase during prolonged tenofovir monotherapy in rhesus macaques with chronic RT-SHIV infection

    Directory of Open Access Journals (Sweden)

    Pedersen Niels C

    2007-04-01

    Full Text Available Abstract Background We reported previously on the emergence and clinical implications of simian immunodeficiency virus (SIVmac251 mutants with a K65R mutation in reverse transcriptase (RT, and the role of CD8+ cell-mediated immune responses in suppressing viremia during tenofovir therapy. Because of significant sequence differences between SIV and HIV-1 RT that affect drug susceptibilities and mutational patterns, it is unclear to what extent findings with SIV can be extrapolated to HIV-1 RT. Accordingly, to model HIV-1 RT responses, 12 macaques were inoculated with RT-SHIV, a chimeric SIV containing HIV-1 RT, and started on prolonged tenofovir therapy 5 months later. Results The early virologic response to tenofovir correlated with baseline viral RNA levels and expression of the MHC class I allele Mamu-A*01. For all animals, sensitive real-time PCR assays detected the transient emergence of K70E RT mutants within 4 weeks of therapy, which were then replaced by K65R mutants within 12 weeks of therapy. For most animals, the occurrence of these mutations preceded a partial rebound of plasma viremia to levels that remained on average 10-fold below baseline values. One animal eventually suppressed K65R viremia to undetectable levels for more than 4 years; sequential experiments using CD8+ cell depletion and tenofovir interruption demonstrated that both CD8+ cells and continued tenofovir therapy were required for sustained suppression of viremia. Conclusion This is the first evidence that tenofovir therapy can select directly for K70E viral mutants in vivo. The observations on the clinical implications of the K65R RT-SHIV mutants were consistent with those of SIVmac251, and suggest that for persons infected with K65R HIV-1 both immune-mediated and drug-dependent antiviral activities play a role in controlling viremia. These findings suggest also that even in the presence of K65R virus, continuation of tenofovir treatment as part of HAART may be

  6. Resource Handbook--Space Beyond the Earth. A Supplement to Basic Curriculum Guide--Science, Grades K-6.

    Science.gov (United States)

    Starr, John W., 3rd., Ed.

    GRADES OR AGES: Grades K-6. SUBJECT MATTER: Science; space. ORGANIZATION AND PHYSICAL APPEARANCE: The guide is divided into four units: 1) the sun, earth, and moon; 2) stars and planets; 3) exploring space; 4) man's existence in space. Each unit includes initiatory and developmental activities. There are also sections on evaluation, vocabulary,…

  7. An Architecture, System Engineering, and Acquisition Approach for Space System Software Resiliency

    Science.gov (United States)

    Phillips, Dewanne Marie

    architecture framework and acquisition methodology to improve the resiliency of space systems from a software perspective with an emphasis on the early phases of the systems engineering life cycle. This methodology involves seven steps: 1) Define technical resiliency requirements, 1a) Identify standards/policy for software resiliency, 2) Develop a request for proposal (RFP)/statement of work (SOW) for resilient space systems software, 3) Define software resiliency goals for space systems, 4) Establish software resiliency quality attributes, 5) Perform architectural tradeoffs and identify risks, 6) Conduct architecture assessments as part of the procurement process, and 7) Ascertain space system software architecture resiliency metrics. Data illustrates that software vulnerabilities can lead to opportunities for malicious cyber activities, which could degrade the space mission capability for the user community. Reducing the number of vulnerabilities by improving architecture and software system engineering practices can contribute to making space systems more resilient. Since cyber-attacks are enabled by shortfalls in software, robust software engineering practices and an architectural design are foundational to resiliency, which is a quality that allows the system to "take a hit to a critical component and recover in a known, bounded, and generally acceptable period of time". To achieve software resiliency for space systems, acquirers and suppliers must identify relevant factors and systems engineering practices to apply across the lifecycle, in software requirements analysis, architecture development, design, implementation, verification and validation, and maintenance phases.

  8. Probing finite coarse-grained virtual Feynman histories with sequential weak values

    Science.gov (United States)

    Georgiev, Danko; Cohen, Eliahu

    2018-05-01

    Feynman's sum-over-histories formulation of quantum mechanics has been considered a useful calculational tool in which virtual Feynman histories entering into a coherent quantum superposition cannot be individually measured. Here we show that sequential weak values, inferred by consecutive weak measurements of projectors, allow direct experimental probing of individual virtual Feynman histories, thereby revealing the exact nature of quantum interference of coherently superposed histories. Because the total sum of sequential weak values of multitime projection operators for a complete set of orthogonal quantum histories is unity, complete sets of weak values could be interpreted in agreement with the standard quantum mechanical picture. We also elucidate the relationship between sequential weak values of quantum histories with different coarse graining in time and establish the incompatibility of weak values for nonorthogonal quantum histories in history Hilbert space. Bridging theory and experiment, the presented results may enhance our understanding of both weak values and quantum histories.

  9. Structural and Functional Impacts of ER Coactivator Sequential Recruitment.

    Science.gov (United States)

    Yi, Ping; Wang, Zhao; Feng, Qin; Chou, Chao-Kai; Pintilie, Grigore D; Shen, Hong; Foulds, Charles E; Fan, Guizhen; Serysheva, Irina; Ludtke, Steven J; Schmid, Michael F; Hung, Mien-Chie; Chiu, Wah; O'Malley, Bert W

    2017-09-07

    Nuclear receptors recruit multiple coactivators sequentially to activate transcription. This "ordered" recruitment allows different coactivator activities to engage the nuclear receptor complex at different steps of transcription. Estrogen receptor (ER) recruits steroid receptor coactivator-3 (SRC-3) primary coactivator and secondary coactivators, p300/CBP and CARM1. CARM1 recruitment lags behind the binding of SRC-3 and p300 to ER. Combining cryo-electron microscopy (cryo-EM) structure analysis and biochemical approaches, we demonstrate that there is a close crosstalk between early- and late-recruited coactivators. The sequential recruitment of CARM1 not only adds a protein arginine methyltransferase activity to the ER-coactivator complex, it also alters the structural organization of the pre-existing ERE/ERα/SRC-3/p300 complex. It induces a p300 conformational change and significantly increases p300 HAT activity on histone H3K18 residues, which, in turn, promotes CARM1 methylation activity on H3R17 residues to enhance transcriptional activity. This study reveals a structural role for a coactivator sequential recruitment and biochemical process in ER-mediated transcription. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Combined Inhibition of CDK4/6 and PI3K/AKT/mTOR Pathways Induces a Synergistic Anti-Tumor Effect in Malignant Pleural Mesothelioma Cells

    Directory of Open Access Journals (Sweden)

    Mara A. Bonelli

    2017-08-01

    Full Text Available Malignant pleural mesothelioma (MPM is a progressive malignancy associated to the exposure of asbestos fibers. The most frequently inactivated tumor suppressor gene in MPM is CDKN2A/ARF, encoding for the cell cycle inhibitors p16INK4a and p14ARF, deleted in about 70% of MPM cases. Considering the high frequency of alterations of this gene, we tested in MPM cells the efficacy of palbociclib (PD-0332991, a highly selective inhibitor of cyclin-dependent kinase (CDK 4/6. The analyses were performed on a panel of MPM cell lines and on two primary culture cells from pleural effusion of patients with MPM. All the MPM cell lines, as well as the primary cultures, were sensitive to palbociclib with a significant blockade in G0/G1 phase of the cell cycle and with the acquisition of a senescent phenotype. Palbociclib reduced the phosphorylation levels of CDK6 and Rb, the expression of myc with a concomitant increased phosphorylation of AKT. Based on these results, we tested the efficacy of the combination of palbociclib with the PI3K inhibitors NVP-BEZ235 or NVP-BYL719. After palbociclib treatment, the sequential association with PI3K inhibitors synergistically hampered cell proliferation and strongly increased the percentage of senescent cells. In addition, AKT activation was repressed while p53 and p21 were up-regulated. Interestingly, two cycles of sequential drug administration produced irreversible growth arrest and senescent phenotype that were maintained even after drug withdrawal. These findings suggest that the sequential association of palbociclib with PI3K inhibitors may represent a valuable therapeutic option for the treatment of MPM.

  11. A 100 kW-Class Technology Demonstrator for Space Solar Power

    Science.gov (United States)

    Carrington, Connie; Howell, Joe; Day, Greg

    2004-01-01

    A first step in the development of solar power from space is the flight demonstration of critical technologies. These fundamental technologies include efficient solar power collection and generation, power management and distribution, and thermal management. In addition, the integration and utilization of these technologies into a viable satellite bus could provide an energy-rich platform for a portfolio of payload experiments such as wireless power transmission (WPT). This paper presents the preliminary design of a concept for a 100 kW-class fiee-flying platform suitable for flight demonstration of technology experiments. Recent space solar power (SSP) studies by NASA have taken a stepping stones approach that lead to the gigawatt systems necessary to cost-effectively deliver power from space. These steps start with a 100 kW-class satellite, leading to a 500 kW and then a 1 MW-class platform. Later steps develop a 100 M W bus that could eventually lead to a 1-2 GW pilot plant for SSP. Our studies have shown that a modular approach is cost effective. Modular designs include individual laser-power-beaming satellites that fly in constellations or that are autonomously assembled into larger structures at geosynchronous orbit (GEO). Microwave power-beamed approaches are also modularized into large numbers of identical units of solar arrays, power converters, or supporting structures for arrays and microwave transmitting antennas. A cost-effective approach to launching these modular units is to use existing Earth-to-orbit (ETO) launch systems, in which the modules are dropped into low Earth orbit (LEO) and then the modules perform their own orbit transfer to GEO using expendable solar arrays to power solar electric thrusters. At GEO, the modules either rendezvous and are assembled robotically into larger platforms, or are deployed into constellations of identical laser power-beaming satellites. Since solar electric propulsion by the modules is cost-effective for both

  12. Reduction of respiratory ghosting motion artifacts in conventional two-dimensional multi-slice Cartesian turbo spin-echo: which k-space filling order is the best?

    Science.gov (United States)

    Inoue, Yuuji; Yoneyama, Masami; Nakamura, Masanobu; Takemura, Atsushi

    2018-06-01

    The two-dimensional Cartesian turbo spin-echo (TSE) sequence is widely used in routine clinical studies, but it is sensitive to respiratory motion. We investigated the k-space orders in Cartesian TSE that can effectively reduce motion artifacts. The purpose of this study was to demonstrate the relationship between k-space order and degree of motion artifacts using a moving phantom. We compared the degree of motion artifacts between linear and asymmetric k-space orders. The actual spacing of ghost artifacts in the asymmetric order was doubled compared with that in the linear order in the free-breathing situation. The asymmetric order clearly showed less sensitivity to incomplete breath-hold at the latter half of the imaging period. Because of the actual number of partitions of the k-space and the temporal filling order, the asymmetric k-space order of Cartesian TSE was superior to the linear k-space order for reduction of ghosting motion artifacts.

  13. Experimental results of a 3 k Wh thermochemical heat storage module for space heating application

    NARCIS (Netherlands)

    Finck, C.J.; Henquet, E.M.R.; Soest, C.F.L. van; Oversloot, H.P.; Jong, A.J. de; Cuypers, R.; Spijker, J.C. van 't

    2014-01-01

    A 3 kWh thermochemical heat storage (TCS) module was built as part of an all-in house system implementation focusing on space heating application at a temperature level of 40 ºC and a temperature lift of 20 K. It has been tested and measurements showed a maximum water circuit temperature span

  14. Status of CEA reactor studies for a 200 kWe turbo electric space power system

    International Nuclear Information System (INIS)

    Carre, F.; Gervaise, F.; Proust, E.; Schwartz, J.P.; Tilliette, Z.; Vrillon, B.

    1986-01-01

    The present European ARIANE space program will expand after 1995 in the development of the large ARIANE 5 launch vehicle. Considering, that the range of power needs (50 to 400 kWe) and operation times required for the space missions planned after the year 2000, are relevant to a nuclear power system, the French Centre National d'Etudes Spatiales (CNES) invited in 1983 the Commissariat a l'Energie Atomique (CEA) to undertake preliminary studies on space power systems. The purpose of the present two year phase (mid 1984-mid 1986) is to identify key technologies for a space generator within the power range of interest and to estimate the development cost of such a project to be examined for commitment in 1986. This work mainly consists in the feasibility and cost assessment of a reference 200 kWe turboelectric space generator, selected for the maturity and availability of the conversion system and for its attractive specific mass compared to thermionics and thermoelectricity, considering the available radiator area afforded by the specific ARIANE 5 geometrical features. The system is basically composed of a fast neutron spectrum lithium cooled reactor, of a Brayton conversion loop and of a heat pipe radiator

  15. Measurement of CP violation in the phase space of B±→K± π+ π- and B±→K± K+ K- decays.

    Science.gov (United States)

    Aaij, R; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amerio, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Andrews, J E; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Baalouch, M; Bachmann, S; Back, J J; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bauer, Th; Bay, A; Beddow, J; Bedeschi, F; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Burducea, I; Bursche, A; Busetto, G; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Castillo Garcia, L; Cattaneo, M; Cauet, Ch; Cenci, R; Charles, M; Charpentier, Ph; Chen, P; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Couturier, B; Cowan, G A; Craik, D C; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; Davis, A; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Del Buono, L; Déléage, N; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Di Ruscio, F; Dijkstra, H; Dogaru, M; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Elsby, D; Falabella, A; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Giubega, L; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Griffith, P; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hamilton, B; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Hartmann, T; He, J; Head, T; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicheur, A; Hicks, E; Hill, D; Hoballah, M; Holtrop, M; Hombach, C; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jans, E; Jaton, P; Jawahery, A; Jing, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Kaballo, M; Kandybei, S; Kanso, W; Karacson, M; Karbach, T M; Kenyon, I R; Ketel, T; Keune, A; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leo, S; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lohn, S; Longstaff, I; Lopes, J H; Lopez-March, N; Lu, H; Lucchesi, D; Luisier, J; Luo, H; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Maurice, E; Mazurov, A; Mc Skelly, B; McCarthy, J; McNab, A; McNulty, R; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M-N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mordà, A; Morello, M J; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neubert, S; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pal, B K; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, A; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Roberts, D A; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rouvinet, J; Ruf, T; Ruffini, F; Ruiz, H; Ruiz Valls, P; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salustino Guimaraes, V; Salzmann, C; Sanmartin Sedes, B; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M-H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Sirendi, M; Skwarnicki, T; Smith, N A; Smith, E; Smith, J; Smith, M; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Sun, L; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urner, D; Ustyuzhanin, A; Uwer, U; Vagnoni, V; Valenti, G; Vallier, A; Van Dijk, M; Vazquez Gomez, R; Vazquez Regueiro, P; Vázquez Sierra, C; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, C; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiechczynski, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wimberley, J; Wishahi, J; Witek, M; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, Z; Yang, Z; Young, R; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2013-09-06

    The charmless decays B±→K± π+ π- and B±→K± K+ K- are reconstructed using data, corresponding to an integrated luminosity of 1.0  fb(-1), collected by LHCb in 2011. The inclusive charge asymmetries of these modes are measured as ACP(B±→K± π+ π-)=0.032±0.008 (stat)±0.004 (syst)±0.007(J/ψK±) and ACP(B±→K± K+ K-)=-0.043±0.009 (stat)±0.003 (syst)±0.007(J/ψK±), where the third uncertainty is due to the CP asymmetry of the B±→J/ψK± reference mode. The significance of ACP(B±→K± K+ K-) exceeds three standard deviations and is the first evidence of an inclusive CP asymmetry in charmless three-body B decays. In addition to the inclusive CP asymmetries, larger asymmetries are observed in localized regions of phase space.

  16. Precision cryogenic temperature data acquisition system

    International Nuclear Information System (INIS)

    Farah, Y.; Sondericker, J.H.

    1985-01-01

    A Multiplexed Temperature Data Acquisition System with an overall precision of +-25 ppM has been designed using state-of-the-art electronics to accurately read temperature between 2.4 K and 600 K from pre-calibrated transducers such as germanium, silicon diode, thermistor or platinum temperature sensors

  17. Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants.

    Science.gov (United States)

    Ben-Eliezer, Noam; Solomon, Eddy; Harel, Elad; Nevo, Nava; Frydman, Lucio

    2012-12-01

    An approach has been recently introduced for acquiring arbitrary 2D NMR spectra or images in a single scan, based on the use of frequency-swept RF pulses for the sequential excitation and acquisition of the spins response. This spatiotemporal-encoding (SPEN) approach enables a unique, voxel-by-voxel refocusing of all frequency shifts in the sample, for all instants throughout the data acquisition. The present study investigates the use of this full-refocusing aspect of SPEN-based imaging in the multi-shot MRI of objects, subject to sizable field inhomogeneities that complicate conventional imaging approaches. 2D MRI experiments were performed at 7 T on phantoms and on mice in vivo, focusing on imaging in proximity to metallic objects. Fully refocused SPEN-based spin echo imaging sequences were implemented, using both Cartesian and back-projection trajectories, and compared with k-space encoded spin echo imaging schemes collected on identical samples under equal bandwidths and acquisition timing conditions. In all cases assayed, the fully refocused spatiotemporally encoded experiments evidenced a ca. 50 % reduction in signal dephasing in the proximity of the metal, as compared to analogous results stemming from the k-space encoded spin echo counterparts. The results in this study suggest that SPEN-based acquisition schemes carry the potential to overcome strong field inhomogeneities, of the kind that currently preclude high-field, high-resolution tissue characterizations in the neighborhood of metallic implants.

  18. Modelling sequentially scored item responses

    NARCIS (Netherlands)

    Akkermans, W.

    2000-01-01

    The sequential model can be used to describe the variable resulting from a sequential scoring process. In this paper two more item response models are investigated with respect to their suitability for sequential scoring: the partial credit model and the graded response model. The investigation is

  19. Portable Data Acquisition System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Armstrong researchers have developed a portable data acquisition system (PDAT) that can be easily transported and set up at remote locations to display and archive...

  20. K-space trajectory mapping and its application for ultrashort Echo time imaging

    Czech Academy of Sciences Publication Activity Database

    Latta, P.; Starčuk jr., Zenon; Gruwel, M. L. H.; Weber, M.H.; Tomanek, B.

    2017-01-01

    Roč. 36, February (2017), s. 68-76 ISSN 0730-725X R&D Projects: GA ČR(CZ) GA15-12607S Institutional support: RVO:68081731 Keywords : gradient imperfections * K-space deviation * trajectrory estaimation * ultrashort echo time Subject RIV: FS - Medical Facilities ; Equipment OBOR OECD: Medical engineering Impact factor: 2.225, year: 2016

  1. Vocal sequential exchanges and intragroup spacing in the Northern Muriqui Brachyteles arachnoides hypoxanthus

    OpenAIRE

    Mendes,Francisco D.C.; Ades,César

    2004-01-01

    Sequential exchanges of vocalizations (staccatos and neighs) emitted by Northern Muriquis Brachyteles arachnoides hypoxanthus were recorded at the Biological Station of Caratinga, Minas Gerais State, Brazil. Staccatos and neighs containing larger proportion of short elements were preferentially produced during short-range exchanges; neighs, produced by a larger number of participants, were typical of long-range exchanges. Staccatos emitted by animals feeding in a dispersed manner contained a ...

  2. Operating software for plutonium measurements in the KfK K-edge densitometer. A user's guide

    International Nuclear Information System (INIS)

    Eberle, H.

    1983-09-01

    A set of computer programs has been developed for the execution of plutonium concentration measurements in the KfK K-edge photon absorptiometer for performance evaluation. The programs are implemented on a ND-6620 data acquisition and processing system. A short description of the programs and commands for data accumulation and analysis is given. Nevertheless, the user should be familiar with the ND-6620 data acquisition and processing system, its system software, and with the FORTRAN programming language. (orig./HP)

  3. Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose.

    Science.gov (United States)

    Wenz, Holger; Maros, Máté E; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas

    2015-01-01

    To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (pspiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels.

  4. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.

    2014-12-15

    This paper considers multi-agent sequential hypothesis testing and presents a framework for strategic learning in sequential games with explicit consideration of both temporal and spatial coordination. The associated Bayes risk functions explicitly incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well-defined value functions with respect to (a) the belief states for the case of conditional independent private noisy measurements that are also assumed to be independent identically distributed over time, and (b) the information states for the case of correlated private noisy measurements. A sequential investment game of strategic coordination and delay is also discussed as an application of the proposed strategic learning rules.

  5. K[subscript a] and K[subscript b] from pH and Conductivity Measurements: A General Chemistry Laboratory Exercise

    Science.gov (United States)

    Nyasulu, Frazier; Moehring, Michael; Arthasery, Phyllis; Barlag, Rebecca

    2011-01-01

    The acid ionization constant, K[subscript a], of acetic acid and the base ionization constant, K[subscript b], of ammonia are determined easily and rapidly using a datalogger, a pH sensor, and a conductivity sensor. To decrease sample preparation time and to minimize waste, sequential aliquots of a concentrated standard are added to a known volume…

  6. A k-space method for acoustic propagation using coupled first-order equations in three dimensions.

    Science.gov (United States)

    Tillett, Jason C; Daoud, Mohammad I; Lacefield, James C; Waag, Robert C

    2009-09-01

    A previously described two-dimensional k-space method for large-scale calculation of acoustic wave propagation in tissues is extended to three dimensions. The three-dimensional method contains all of the two-dimensional method features that allow accurate and stable calculation of propagation. These features are spectral calculation of spatial derivatives, temporal correction that produces exact propagation in a homogeneous medium, staggered spatial and temporal grids, and a perfectly matched boundary layer. Spectral evaluation of spatial derivatives is accomplished using a fast Fourier transform in three dimensions. This computational bottleneck requires all-to-all communication; execution time in a parallel implementation is therefore sensitive to node interconnect latency and bandwidth. Accuracy of the three-dimensional method is evaluated through comparisons with exact solutions for media having spherical inhomogeneities. Large-scale calculations in three dimensions were performed by distributing the nearly 50 variables per voxel that are used to implement the method over a cluster of computers. Two computer clusters used to evaluate method accuracy are compared. Comparisons of k-space calculations with exact methods including absorption highlight the need to model accurately the medium dispersion relationships, especially in large-scale media. Accurately modeled media allow the k-space method to calculate acoustic propagation in tissues over hundreds of wavelengths.

  7. Technical Note: Interleaved Bipolar Acquisition and Low-rank Reconstruction for Water-Fat Separation in MRI.

    Science.gov (United States)

    Cho, JaeJin; Park, HyunWook

    2018-05-17

    To acquire interleaved bipolar data and reconstruct the full data using low-rank property for water fat separation. Bipolar acquisition suffers from issues related to gradient switching, the opposite gradient polarities, and other system imperfections, which prevent accurate water-fat separation. In this study, an interleaved bipolar acquisition scheme and a low-rank reconstruction method were proposed to reduce issues from the bipolar gradients while achieving a short imaging time. The proposed interleaved bipolar acquisition scheme collects echo-time signals from both gradient polarities; however, the sequence increases the imaging time. To reduce the imaging time, the signals were subsampled at every dimension of k-space. The low-rank property of the bipolar acquisition was defined and exploited to estimate the full data from the acquired subsampled data. To eliminate the bipolar issues, in the proposed method, the water-fat separation was performed separately for each gradient polarity, and the results for the positive and negative gradient polarities were combined after the water-fat separation. A phantom study and in-vivo experiments were conducted on a 3T Siemens Verio system. The results for the proposed method were compared with the results of the fully sampled interleaved bipolar acquisition and Soliman's method, which was the previous water-fat separation approach for reducing the issues of bipolar gradients and accelerating the interleaved bipolar acquisition. The proposed method provided accurate water and fat images without the issues of bipolar gradients and demonstrated a better performance compared with the results of the previous methods. The water-fat separation using the bipolar acquisition has several benefits including a short echo-spacing time. However, it suffers from bipolar-gradient issues such as strong gradient switching, system imperfection, and eddy current effects. This study demonstrated that accurate water-fat separated images can

  8. Solid state NMR of proteins at high MAS frequencies: symmetry-based mixing and simultaneous acquisition of chemical shift correlation spectra

    International Nuclear Information System (INIS)

    Bellstedt, Peter; Herbst, Christian; Häfner, Sabine; Leppert, Jörg; Görlach, Matthias; Ramachandran, Ramadurai

    2012-01-01

    We have carried out chemical shift correlation experiments with symmetry-based mixing sequences at high MAS frequencies and examined different strategies to simultaneously acquire 3D correlation spectra that are commonly required in the structural studies of proteins. The potential of numerically optimised symmetry-based mixing sequences and the simultaneous recording of chemical shift correlation spectra such as: 3D NCAC and 3D NHH with dual receivers, 3D NC′C and 3D C′NCA with sequential 13 C acquisitions, 3D NHH and 3D NC′H with sequential 1 H acquisitions and 3D CANH and 3D C’NH with broadband 13 C– 15 N mixing are demonstrated using microcrystalline samples of the β1 immunoglobulin binding domain of protein G (GB1) and the chicken α-spectrin SH3 domain.

  9. Sequential charged particle reaction

    International Nuclear Information System (INIS)

    Hori, Jun-ichi; Ochiai, Kentaro; Sato, Satoshi; Yamauchi, Michinori; Nishitani, Takeo

    2004-01-01

    The effective cross sections for producing the sequential reaction products in F82H, pure vanadium and LiF with respect to the 14.9-MeV neutron were obtained and compared with the estimation ones. Since the sequential reactions depend on the secondary charged particles behavior, the effective cross sections are corresponding to the target nuclei and the material composition. The effective cross sections were also estimated by using the EAF-libraries and compared with the experimental ones. There were large discrepancies between estimated and experimental values. Additionally, we showed the contribution of the sequential reaction on the induced activity and dose rate in the boundary region with water. From the present study, it has been clarified that the sequential reactions are of great importance to evaluate the dose rates around the surface of cooling pipe and the activated corrosion products. (author)

  10. A sequential EMT-MET mechanism drives the differentiation of human embryonic stem cells towards hepatocytes.

    Science.gov (United States)

    Li, Qiuhong; Hutchins, Andrew P; Chen, Yong; Li, Shengbiao; Shan, Yongli; Liao, Baojian; Zheng, Dejin; Shi, Xi; Li, Yinxiong; Chan, Wai-Yee; Pan, Guangjin; Wei, Shicheng; Shu, Xiaodong; Pei, Duanqing

    2017-05-03

    Reprogramming has been shown to involve EMT-MET; however, its role in cell differentiation is unclear. We report here that in vitro differentiation of hESCs to hepatic lineage undergoes a sequential EMT-MET with an obligatory intermediate mesenchymal phase. Gene expression analysis reveals that Activin A-induced formation of definitive endoderm (DE) accompanies a synchronous EMT mediated by autocrine TGFβ signalling followed by a MET process. Pharmacological inhibition of TGFβ signalling blocks the EMT as well as DE formation. We then identify SNAI1 as the key EMT transcriptional factor required for the specification of DE. Genetic ablation of SNAI1 in hESCs does not affect the maintenance of pluripotency or neural differentiation, but completely disrupts the formation of DE. These results reveal a critical mesenchymal phase during the acquisition of DE, highlighting a role for sequential EMT-METs in both differentiation and reprogramming.

  11. Reducing contrast contamination in radial turbo-spin-echo acquisitions by combining a narrow-band KWIC filter with parallel imaging.

    Science.gov (United States)

    Neumann, Daniel; Breuer, Felix A; Völker, Michael; Brandt, Tobias; Griswold, Mark A; Jakob, Peter M; Blaimer, Martin

    2014-12-01

    Cartesian turbo spin-echo (TSE) and radial TSE images are usually reconstructed by assembling data containing different contrast information into a single k-space. This approach results in mixed contrast contributions in the images, which may reduce their diagnostic value. The goal of this work is to improve the image contrast from radial TSE acquisitions by reducing the contribution of signals with undesired contrast information. Radial TSE acquisitions allow the reconstruction of multiple images with different T2 contrasts using the k-space weighted image contrast (KWIC) filter. In this work, the image contrast is improved by reducing the band-width of the KWIC filter. Data for the reconstruction of a single image are selected from within a small temporal range around the desired echo time. The resulting dataset is undersampled and, therefore, an iterative parallel imaging algorithm is applied to remove aliasing artifacts. Radial TSE images of the human brain reconstructed with the proposed method show an improved contrast when compared with Cartesian TSE images or radial TSE images with conventional KWIC reconstructions. The proposed method provides multi-contrast images from radial TSE data with contrasts similar to multi spin-echo images. Contaminations from unwanted contrast weightings are strongly reduced. © 2014 Wiley Periodicals, Inc.

  12. Electric propulsion options for 10 kW class earth space missions

    Science.gov (United States)

    Patterson, M. J.; Curran, Francis M.

    1989-01-01

    Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment have been evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA II 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10(7) to 2.1x10(7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA II 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10(6) to 3.6x10(6) N-s, and approximately 662 to 1072 m/s, respectively.

  13. Electric Propulsion Options for 10 kW Class Earth-Space Missions

    Science.gov (United States)

    Patterson, M. J.; Curran, Francis M.

    1989-01-01

    Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment were evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA 2 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10 (exp 7) to 2.1x10 (exp 7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA 2 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10 (exp 6) to 3.6x10 (exp 6) N-s, and approximately 662 to 1072 m/s, respectively.

  14. Eyewitness confidence in simultaneous and sequential lineups: a criterion shift account for sequential mistaken identification overconfidence.

    Science.gov (United States)

    Dobolyi, David G; Dodson, Chad S

    2013-12-01

    Confidence judgments for eyewitness identifications play an integral role in determining guilt during legal proceedings. Past research has shown that confidence in positive identifications is strongly associated with accuracy. Using a standard lineup recognition paradigm, we investigated accuracy using signal detection and ROC analyses, along with the tendency to choose a face with both simultaneous and sequential lineups. We replicated past findings of reduced rates of choosing with sequential as compared to simultaneous lineups, but notably found an accuracy advantage in favor of simultaneous lineups. Moreover, our analysis of the confidence-accuracy relationship revealed two key findings. First, we observed a sequential mistaken identification overconfidence effect: despite an overall reduction in false alarms, confidence for false alarms that did occur was higher with sequential lineups than with simultaneous lineups, with no differences in confidence for correct identifications. This sequential mistaken identification overconfidence effect is an expected byproduct of the use of a more conservative identification criterion with sequential than with simultaneous lineups. Second, we found a steady drop in confidence for mistaken identifications (i.e., foil identifications and false alarms) from the first to the last face in sequential lineups, whereas confidence in and accuracy of correct identifications remained relatively stable. Overall, we observed that sequential lineups are both less accurate and produce higher confidence false identifications than do simultaneous lineups. Given the increasing prominence of sequential lineups in our legal system, our data argue for increased scrutiny and possibly a wholesale reevaluation of this lineup format. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  15. Development of induction current acquisition device based on ARM

    Science.gov (United States)

    Ji, Yanju; Liu, Xiyang; Huang, Wanyu; Yao, Jiang; Yuan, Guiyang; Hui, Luan; Guan, Shanshan

    2018-03-01

    We design an induction current acquisition device based on ARM in order to realize high resolution and high sampling rate of acquisition for the induction current in wire-loop. Considering its characteristics of fast attenuation and small signal amplitude, we use the method of multi-path fusion for noise suppression. In the paper, the design is carried out from three aspects of analog circuit and device selection, independent power supply structure and the electromagnetic interference suppression of high frequency. DMA and ping-pong buffer, as a new data transmission technology, solves real time storage problem of massive data. The performance parameters of ARM acquisition device are tested. The comparison test of ARM acquisition device and cRIO acquisition device is performed at different time constants. The results show that it has 120dB dynamic range, 47kHz bandwidth, 96kHz sampling rate, 5μV the smallest resolution, and its average error value is not more than 4%, which proves the high accuracy and stability of the device.

  16. Minicomputer data acquisition system for nuclear physics applications

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, R [Princeton Univ., NJ (USA). Joseph Henry Labs.

    1978-09-15

    The data acquisition system for the Princeton Cyclotron facility based on a Data General Eclipse computer is described. The program ACQUIRE is a highly flexible acquisition code able to support diverse experimental requirements and yet capable of sorting a repetitious pulser in a single ADC at up to 40 kHz without loss.

  17. Sequential egocentric navigation and reliance on landmarks in Williams syndrome and typical development

    Directory of Open Access Journals (Sweden)

    Hannah eBroadbent

    2015-02-01

    Full Text Available Visuospatial difficulties in Williams syndrome (WS are well documented. Recently, research has shown that spatial difficulties in WS extend to large-scale space, particularly in coding space using an allocentric frame of reference. Typically developing (TD children and adults predominantly rely on the use of a sequential egocentric strategy to navigate a large-scale route (retracing a sequence of left-right body turns. The aim of this study was to examine whether individuals with WS are able to employ a sequential egocentric strategy to guide learning and the retracing of a route. Forty-eight TD children, aged 5, 7 and 9 years and 18 participants with WS were examined on their ability to learn and retrace routes in two (6-turn virtual environment mazes (with and without landmarks. The ability to successfully retrace a route following the removal of landmarks (use of sequential egocentric coding was also examined.Although in line with TD 5 year-olds when learning a route with landmarks, individuals with WS showed significantly greater detriment when these landmarks were removed, relative to all TD groups. Moreover, the WS group made significantly more errors than all TD groups when learning a route that never contained landmarks. On a perceptual view-matching task, results revealed a high level of performance across groups, indicative of an ability to use this visual information to potentially aid navigation. These findings suggest that individuals with WS rely on landmarks to a greater extent than TD children, both for learning a route and for retracing a recently learned route. TD children, but not individuals with WS, were able to fall back on the use of a sequential egocentric strategy to navigate when landmarks were not present. Only TD children therefore coded sequential route information simultaneously with landmark information. The results are discussed in relation to known atypical cortical development and perceptual-matching abilities

  18. Silhouette-based approach of 3D image reconstruction for automated image acquisition using robotic arm

    Science.gov (United States)

    Azhar, N.; Saad, W. H. M.; Manap, N. A.; Saad, N. M.; Syafeeza, A. R.

    2017-06-01

    This study presents the approach of 3D image reconstruction using an autonomous robotic arm for the image acquisition process. A low cost of the automated imaging platform is created using a pair of G15 servo motor connected in series to an Arduino UNO as a main microcontroller. Two sets of sequential images were obtained using different projection angle of the camera. The silhouette-based approach is used in this study for 3D reconstruction from the sequential images captured from several different angles of the object. Other than that, an analysis based on the effect of different number of sequential images on the accuracy of 3D model reconstruction was also carried out with a fixed projection angle of the camera. The effecting elements in the 3D reconstruction are discussed and the overall result of the analysis is concluded according to the prototype of imaging platform.

  19. CH-53K Heavy Lift Replacement Helicopter (CH-53K)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-390 CH-53K Heavy Lift Replacement Helicopter (CH-53K) As of FY 2017 President’s Budget...December 2015 SAR March 4, 2016 10:04:18 UNCLASSIFIED 4 Col Henry Vanderborght PMA-261 Heavy Lift Helicopters Program Executive Office - Air, Anti...757-5780 Fax: 301-757-5109 DSN Phone: 757-5780 DSN Fax: 757-5109 Date Assigned: May 29, 2014 Program Information Program Name CH-53K Heavy Lift

  20. Cryogenic Liquid Sample Acquisition System for Remote Space Applications

    Science.gov (United States)

    Mahaffy, Paul; Trainer, Melissa; Wegel, Don; Hawk, Douglas; Melek, Tony; Johnson, Christopher; Amato, Michael; Galloway, John

    2013-01-01

    There is a need to acquire autonomously cryogenic hydrocarbon liquid sample from remote planetary locations such as the lakes of Titan for instruments such as mass spectrometers. There are several problems that had to be solved relative to collecting the right amount of cryogenic liquid sample into a warmer spacecraft, such as not allowing the sample to boil off or fractionate too early; controlling the intermediate and final pressures within carefully designed volumes; designing for various particulates and viscosities; designing to thermal, mass, and power-limited spacecraft interfaces; and reducing risk. Prior art inlets for similar instruments in spaceflight were designed primarily for atmospheric gas sampling and are not useful for this front-end application. These cryogenic liquid sample acquisition system designs for remote space applications allow for remote, autonomous, controlled sample collections of a range of challenging cryogenic sample types. The design can control the size of the sample, prevent fractionation, control pressures at various stages, and allow for various liquid sample levels. It is capable of collecting repeated samples autonomously in difficult lowtemperature conditions often found in planetary missions. It is capable of collecting samples for use by instruments from difficult sample types such as cryogenic hydrocarbon (methane, ethane, and propane) mixtures with solid particulates such as found on Titan. The design with a warm actuated valve is compatible with various spacecraft thermal and structural interfaces. The design uses controlled volumes, heaters, inlet and vent tubes, a cryogenic valve seat, inlet screens, temperature and cryogenic liquid sensors, seals, and vents to accomplish its task.

  1. Medical and surgical applications of space biosensor technology

    Science.gov (United States)

    Hines, J. W.

    1996-01-01

    Researchers in space life sciences are rapidly approaching a technology impasse. Many of the critical questions on the impact of spaceflight on living systems simply cannot be answered with the limited available technologies. Research subjects, particularly small animal models like the rat, must be allowed to function relatively untended and unrestrained for long periods to fully reflect the impact of microgravity and spaceflight on their behavior and physiology. These requirements preclude the use of present hard-wired instrumentation techniques and limited data acquisition systems. Implantable sensors and miniaturized biotelemetry are the only means of capturing the fundamental and critical data. This same biosensor and biotelemetry technology has direct application to Earth-based medicine and surgery. Continuous, on-line data acquisition and improved measurement capabilities combined with the ease and flexibility offered by automated, wireless, and portable instruments and data systems, should provide a boon to the health care industry. Playing a key role in this technology revolution is the Sensors 2000! (S2K!) Program at NASA Ames Research Center. S2K!, in collaboration with space life sciences researchers and managers, provides an integrated capability for sensor technology development and applications, including advanced biosensor technology development, spaceflight hardware development, and technology transfer and commercialization. S2K! is presently collaborating on several spaceflight projects with dual-use medical applications. One prime example is a collaboration with the Fetal Treatment Center (FTC) at the University of California at San Francisco. The goal is to develop and apply implantable chemical sensor and biotelemetry technology to continuously monitor fetal patients during extra-uterine surgery, replacement into the womb, through birth and beyond. Once validated for ground use, the method will be transitioned to spaceflight applications to

  2. Medical and surgical applications of space biosensor technology

    Science.gov (United States)

    Hines, John W.

    1996-02-01

    Researchers in space life sciences are rapidly approaching a technology impasse. Many of the critical questions on the impact of spaceflight on living systems simply cannot be answered with the limited available technologies. Research subjects, particularly small animal models like the rat, must be allowed to function relatively untended and unrestrained for long periods to fully reflect the impact of microgravity and spaceflight on their behavior and physiology. These requirements preclude the use of present hard-wired instrumentation techniques and limited data acquisition systems. Implantable sensors and miniaturized biotelemetry are the only means of capturing the fundamental and critical data. This same biosensor and biotelemetry technology has direct application to Earth-based medicine and surgery. Continuous, on-line data acquisition and improved measurement capabilities combined with the ease and flexibility offered by automated, wireless, and portable instruments and data systems, should provide a boon to the health care industry. Playing a key role in this technology revolution is the Sensors 2000! (S2K!) Program at NASA Ames Research Center. S2K!, in collaboration with space life sciences researchers and managers, provides an integrated capability for sensor technology development and applications, including advanced biosensor technology development, spaceflight hardware development, and technology transfer and commercialization. S2K! is presently collaborating on several spaceflight projects with dual-use medical applications. One prime example is a collaboration with the Fetal Treatment Center (FTC) at the University of California at San Francisco. The goal is to develop and apply implantable chemical sensor and biotelemetry technology to continuously monitor fetal patients during extra-uterine surgery, replacement into the womb, through birth and beyond. Once validated for ground use, the method will be transitioned to spaceflight applications to

  3. Banach spaces of continuous functions as dual spaces

    CERN Document Server

    Dales, H G; Lau, A T -M; Strauss, D

    2016-01-01

    This book gives a coherent account of the theory of Banach spaces and Banach lattices, using the spaces C_0(K) of continuous functions on a locally compact space K as the main example. The study of C_0(K) has been an important area of functional analysis for many years. It gives several new constructions, some involving Boolean rings, of this space as well as many results on the Stonean space of Boolean rings. The book also discusses when Banach spaces of continuous functions are dual spaces and when they are bidual spaces.

  4. Solid state NMR of proteins at high MAS frequencies: symmetry-based mixing and simultaneous acquisition of chemical shift correlation spectra

    Energy Technology Data Exchange (ETDEWEB)

    Bellstedt, Peter [Fritz Lipmann Institute, Biomolecular NMR spectroscopy, Leibniz Institute for Age Research (Germany); Herbst, Christian [Ubon Ratchathani University, Department of Physics, Faculty of Science (Thailand); Haefner, Sabine; Leppert, Joerg; Goerlach, Matthias; Ramachandran, Ramadurai, E-mail: raman@fli-leibniz.de [Fritz Lipmann Institute, Biomolecular NMR spectroscopy, Leibniz Institute for Age Research (Germany)

    2012-12-15

    We have carried out chemical shift correlation experiments with symmetry-based mixing sequences at high MAS frequencies and examined different strategies to simultaneously acquire 3D correlation spectra that are commonly required in the structural studies of proteins. The potential of numerically optimised symmetry-based mixing sequences and the simultaneous recording of chemical shift correlation spectra such as: 3D NCAC and 3D NHH with dual receivers, 3D NC Prime C and 3D C Prime NCA with sequential {sup 13}C acquisitions, 3D NHH and 3D NC Prime H with sequential {sup 1}H acquisitions and 3D CANH and 3D C'NH with broadband {sup 13}C-{sup 15}N mixing are demonstrated using microcrystalline samples of the {beta}1 immunoglobulin binding domain of protein G (GB1) and the chicken {alpha}-spectrin SH3 domain.

  5. Remarks on sequential designs in risk assessment

    International Nuclear Information System (INIS)

    Seidenfeld, T.

    1982-01-01

    The special merits of sequential designs are reviewed in light of particular challenges that attend risk assessment for human population. The kinds of ''statistical inference'' are distinguished and the problem of design which is pursued is the clash between Neyman-Pearson and Bayesian programs of sequential design. The value of sequential designs is discussed and the Neyman-Pearson vs. Bayesian sequential designs are probed in particular. Finally, warnings with sequential designs are considered, especially in relation to utilitarianism

  6. A hybrid sequential approach for data clustering using K-Means and ...

    African Journals Online (AJOL)

    Experiments on four kinds of data sets have been conducted. The obtained results are compared with K-Means, PSO, Hybrid, K-Means+Genetic Algorithm and it has been found that the proposed algorithm generates more accurate, robust and better clustering results. International Journal of Engineering, Science and ...

  7. Department of Defense Weapon System Acquisition Policy: A System Dynamics Model and Analysis.

    Science.gov (United States)

    1982-09-01

    dimensionless) PRPRD = Perceived Pressure for R&D (dimensionless) PU - Programs in Progress (programs) RPRD - Raw Pressure for R&D (dimensionless) TDPP - Time...ECAP) TH9 Pressure Ra Pressure_.- for Acquisition ( TDPP ) TH25 4for Acquisition (DPFAO) TH22D (DPPFAO) TH21 US Intelligence \\ - 7 Delay Time / efense...DIBP, DPPFAQ. K) TH22 A CPPFAG.K=DLINF3(RPFAG.KTCPP) TH23 A CPFAQ.K=MAX (DIBPCPPFAQ.K) TH24 C TDPP =12 TH25 C TCPP-24 TH26 CPFAQ Congressional Pressure

  8. Sequential lineup laps and eyewitness accuracy.

    Science.gov (United States)

    Steblay, Nancy K; Dietrich, Hannah L; Ryan, Shannon L; Raczynski, Jeanette L; James, Kali A

    2011-08-01

    Police practice of double-blind sequential lineups prompts a question about the efficacy of repeated viewings (laps) of the sequential lineup. Two laboratory experiments confirmed the presence of a sequential lap effect: an increase in witness lineup picks from first to second lap, when the culprit was a stranger. The second lap produced more errors than correct identifications. In Experiment 2, lineup diagnosticity was significantly higher for sequential lineup procedures that employed a single versus double laps. Witnesses who elected to view a second lap made significantly more errors than witnesses who chose to stop after one lap or those who were required to view two laps. Witnesses with prior exposure to the culprit did not exhibit a sequential lap effect.

  9. Modern methods in topological vector spaces

    CERN Document Server

    Wilansky, Albert

    2013-01-01

    Designed for a one-year course in topological vector spaces, this text is geared toward advanced undergraduates and beginning graduate students of mathematics. The subjects involve properties employed by researchers in classical analysis, differential and integral equations, distributions, summability, and classical Banach and Frechét spaces. Optional problems with hints and references introduce non-locally convex spaces, Köthe-Toeplitz spaces, Banach algebra, sequentially barrelled spaces, and norming subspaces.Extensive introductory chapters cover metric ideas, Banach space, topological vect

  10. Robustness of the Sequential Lineup Advantage

    Science.gov (United States)

    Gronlund, Scott D.; Carlson, Curt A.; Dailey, Sarah B.; Goodsell, Charles A.

    2009-01-01

    A growing movement in the United States and around the world involves promoting the advantages of conducting an eyewitness lineup in a sequential manner. We conducted a large study (N = 2,529) that included 24 comparisons of sequential versus simultaneous lineups. A liberal statistical criterion revealed only 2 significant sequential lineup…

  11. Y2K+1: Technology, Community-College Students, the Millennium, and Stanley Kubrick's "2001: A Space Odyssey."

    Science.gov (United States)

    Haspel, Paul

    2002-01-01

    Considers how screening Stanley Kubrick's "2001: A Space Odyssey" in a sophomore film class shows modern community-college students that millennial anxiety existed well before late 1999, the time of "Y2K" fears. Presents an assignment that examines "2001: A Space Odyssey" in the context of its time and in 2001. (SG)

  12. Experimental MR-guided cryotherapy of the brain with almost real-time imaging by radial k-space scanning

    International Nuclear Information System (INIS)

    Tacke, J.; Schorn, R.; Glowinski, A.; Grosskortenhaus, S.; Adam, G.; Guenther, R.W.; Rasche, V.

    1999-01-01

    Purpose: To test radial k-space scanning by MR fluoroscopy to guide and control MR-guided interstitial cryotherapy of the healthy pig brain. Methods: After MR tomographic planning of the approach, an MR-compatible experimental cryotherapy probe of 2.7 mm diameter was introduced through a 5 mm burr hole into the right frontal brain of five healthy pigs. The freeze-thaw cycles were imaged using a T 1 -weighted gradient echo sequence with radial k-space scanning in coronal, sagittal, and axial directions. Results: The high temporal resolution of the chosen sequence permits a continuous representation of the freezing process with good image quality and high contrast between ice and unfrozen brain parenchyma. Because of the interactive conception of the sequence the layer plane could be chosen as desired during the measurement. Ice formation was sharply demarcated, spherically configurated, and was free of signals. Its maximum diameter was 13 mm. Conclusions: With use of the novel, interactively controllable gradient echo sequence with radial k-space scanning, guidance of the intervention under fluoroscopic conditions with the advantages of MRT is possible. MR-guided cryotherapy allows a minimally-invasive, precisely dosable focal tissue ablation. (orig.) [de

  13. Multi-agent sequential hypothesis testing

    KAUST Repository

    Kim, Kwang-Ki K.; Shamma, Jeff S.

    2014-01-01

    incorporate costs of taking private/public measurements, costs of time-difference and disagreement in actions of agents, and costs of false declaration/choices in the sequential hypothesis testing. The corresponding sequential decision processes have well

  14. Sequential x-ray diffraction topography at 1-BM x-ray optics testing beamline at the advanced photon source

    Energy Technology Data Exchange (ETDEWEB)

    Stoupin, Stanislav, E-mail: sstoupin@aps.anl.gov; Shvyd’ko, Yuri; Trakhtenberg, Emil; Liu, Zunping; Lang, Keenan; Huang, Xianrong; Wieczorek, Michael; Kasman, Elina; Hammonds, John; Macrander, Albert; Assoufid, Lahsen [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2016-07-27

    We report progress on implementation and commissioning of sequential X-ray diffraction topography at 1-BM Optics Testing Beamline of the Advanced Photon Source to accommodate growing needs of strain characterization in diffractive crystal optics and other semiconductor single crystals. The setup enables evaluation of strain in single crystals in the nearly-nondispersive double-crystal geometry. Si asymmetric collimator crystals of different crystallographic orientations were designed, fabricated and characterized using in-house capabilities. Imaging the exit beam using digital area detectors permits rapid sequential acquisition of X-ray topographs at different angular positions on the rocking curve of a crystal under investigation. Results on sensitivity and spatial resolution are reported based on experiments with high-quality Si and diamond crystals. The new setup complements laboratory-based X-ray topography capabilities of the Optics group at the Advanced Photon Source.

  15. K-maps: a vehicle to an optimal solution in combinational logic ...

    African Journals Online (AJOL)

    K-maps: a vehicle to an optimal solution in combinational logic design problems using digital multiplexers. ... Abstract. Application of Karnaugh maps (K-Maps) for the design of combinational logic circuits and sequential logic circuits is a subject that has been widely discussed. However, the use of K-Maps in the design of ...

  16. Sequential stochastic optimization

    CERN Document Server

    Cairoli, Renzo

    1996-01-01

    Sequential Stochastic Optimization provides mathematicians and applied researchers with a well-developed framework in which stochastic optimization problems can be formulated and solved. Offering much material that is either new or has never before appeared in book form, it lucidly presents a unified theory of optimal stopping and optimal sequential control of stochastic processes. This book has been carefully organized so that little prior knowledge of the subject is assumed; its only prerequisites are a standard graduate course in probability theory and some familiarity with discrete-paramet

  17. Sequential strand displacement beacon for detection of DNA coverage on functionalized gold nanoparticles.

    Science.gov (United States)

    Paliwoda, Rebecca E; Li, Feng; Reid, Michael S; Lin, Yanwen; Le, X Chris

    2014-06-17

    Functionalizing nanomaterials for diverse analytical, biomedical, and therapeutic applications requires determination of surface coverage (or density) of DNA on nanomaterials. We describe a sequential strand displacement beacon assay that is able to quantify specific DNA sequences conjugated or coconjugated onto gold nanoparticles (AuNPs). Unlike the conventional fluorescence assay that requires the target DNA to be fluorescently labeled, the sequential strand displacement beacon method is able to quantify multiple unlabeled DNA oligonucleotides using a single (universal) strand displacement beacon. This unique feature is achieved by introducing two short unlabeled DNA probes for each specific DNA sequence and by performing sequential DNA strand displacement reactions. Varying the relative amounts of the specific DNA sequences and spacing DNA sequences during their coconjugation onto AuNPs results in different densities of the specific DNA on AuNP, ranging from 90 to 230 DNA molecules per AuNP. Results obtained from our sequential strand displacement beacon assay are consistent with those obtained from the conventional fluorescence assays. However, labeling of DNA with some fluorescent dyes, e.g., tetramethylrhodamine, alters DNA density on AuNP. The strand displacement strategy overcomes this problem by obviating direct labeling of the target DNA. This method has broad potential to facilitate more efficient design and characterization of novel multifunctional materials for diverse applications.

  18. Development and application of a model for the analysis of trades between space launch system operations and acquisition costs

    Science.gov (United States)

    Nix, Michael B.

    2005-12-01

    Early design decisions in the development of space launch systems determine the costs to acquire and operate launch systems. Some sources indicate that as much as 90% of life cycle costs are fixed by the end of the critical design review phase. System characteristics determined by these early decisions are major factors in the acquisition cost of flight hardware elements and facilities and influence operations costs through the amount of maintenance and support labor required to sustain system function. Operations costs are also dependent on post-development management decisions regarding how much labor will be deployed to meet requirements of market demand and ownership profit. The ability to perform early trade-offs between these costs is vital to the development of systems that have the necessary capacity to provide service and are profitable to operate. An Excel-based prototype model was developed for making early analyses of trade-offs between the costs to operate a space launch system and to acquire the necessary assets to meet a given set of operational requirements. The model, integrating input from existing models and adding missing capability, allows the user to make such trade-offs across a range of operations concepts (required flight rates, staffing levels, shifts per workday, workdays per week and per year, unreliability, wearout and depot maintenance) and the number, type and capability of assets (flight hardware elements, processing and supporting facilities and infrastructure). The costs and capabilities of hypothetical launch systems can be modeled as a function of interrelated turnaround times and labor resource levels, and asset loss and retirement. The number of flight components and facilities required can be calculated and the operations and acquisition costs compared for a specified scenario. Findings, based on the analysis of a hypothetical two stage to orbit, reusable, unmanned launch system, indicate that the model is suitable for the

  19. Exploring the sequential lineup advantage using WITNESS.

    Science.gov (United States)

    Goodsell, Charles A; Gronlund, Scott D; Carlson, Curt A

    2010-12-01

    Advocates claim that the sequential lineup is an improvement over simultaneous lineup procedures, but no formal (quantitatively specified) explanation exists for why it is better. The computational model WITNESS (Clark, Appl Cogn Psychol 17:629-654, 2003) was used to develop theoretical explanations for the sequential lineup advantage. In its current form, WITNESS produced a sequential advantage only by pairing conservative sequential choosing with liberal simultaneous choosing. However, this combination failed to approximate four extant experiments that exhibited large sequential advantages. Two of these experiments became the focus of our efforts because the data were uncontaminated by likely suspect position effects. Decision-based and memory-based modifications to WITNESS approximated the data and produced a sequential advantage. The next step is to evaluate the proposed explanations and modify public policy recommendations accordingly.

  20. Data acquisition instruments: Psychopharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, D.S. III

    1998-01-01

    This report contains the results of a Direct Assistance Project performed by Lockheed Martin Energy Systems, Inc., for Dr. K. O. Jobson. The purpose of the project was to perform preliminary analysis of the data acquisition instruments used in the field of psychiatry, with the goal of identifying commonalities of data and strategies for handling and using the data in the most advantageous fashion. Data acquisition instruments from 12 sources were provided by Dr. Jobson. Several commonalities were identified and a potentially useful data strategy is reported here. Analysis of the information collected for utility in performing diagnoses is recommended. In addition, further work is recommended to refine the commonalities into a directly useful computer systems structure.

  1. Search for CP violation using triple product asymmetries in $\\Lambda^{0}_{b}\\to pK^{-}\\pi^{+}\\pi^{-}$, $\\Lambda^{0}_{b}\\to pK^{-}K^{+}K^{-}$ and $\\Xi^{0}_{b}\\to pK^{-}K^{-}\\pi^{+}$ decays arXiv

    CERN Document Server

    INSPIRE-00258707; Adeva, B.; Adinolfi, M.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M.; Albero, A. Alfonso; Ali, S.; Alkhazov, G.; Alvarez Cartelle, P.; Alves, A.A.; Amato, S.; Amerio, S.; Amhis, Y.; An, L.; Anderlini, L.; Andreassi, G.; Andreotti, M.; Andrews, J.E.; Appleby, R.B.; Archilli, F.; d'Argent, P.; Arnau Romeu, J.; Artamonov, A.; Artuso, M.; Aslanides, E.; Atzeni, M.; Auriemma, G.; Babuschkin, I.; Bachmann, S.; Back, J.J.; Badalov, A.; Baesso, C.; Baker, S.; Balagura, V.; Baldini, W.; Baranov, A.; Barlow, R.J.; Barschel, C.; Barsuk, S.; Barter, W.; Baryshnikov, F.; Batozskaya, V.; Battista, V.; Bay, A.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Beiter, A.; Bel, L.J.; Beliy, N.; Bellee, V.; Belloli, N.; Belous, K.; Belyaev, I.; Ben-Haim, E.; Bencivenni, G.; Benson, S.; Beranek, S.; Berezhnoy, A.; Bernet, R.; Berninghoff, D.; Bertholet, E.; Bertolin, A.; Betancourt, C.; Betti, F.; Bettler, M.O.; van Beuzekom, M.; Bezshyiko, Ia.; Bifani, S.; Billoir, P.; Birnkraut, A.; Bizzeti, A.; Bjørn, M.; Blake, T.; Blanc, F.; Blusk, S.; Bocci, V.; Boettcher, T.; Bondar, A.; Bondar, N.; Bordyuzhin, I.; Borghi, S.; Borisyak, M.; Borsato, M.; Bossu, F.; Boubdir, M.; Bowcock, T.J.V.; Bowen, E.; Bozzi, C.; Braun, S.; Brodzicka, J.; Brundu, D.; Buchanan, E.; Burr, C.; Bursche, A.; Buytaert, J.; Byczynski, W.; Cadeddu, S.; Cai, H.; Calabrese, R.; Calladine, R.; Calvi, M.; Calvo Gomez, M.; Camboni, A.; Campana, P.; Perez, D.H. Campora; Capriotti, L.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carniti, P.; Carson, L.; Carvalho Akiba, K.; Casse, G.; Cassina, L.; Cattaneo, M.; Cavallero, G.; Cenci, R.; Chamont, D.; Chapman, M.G.; Charles, M.; Charpentier, Ph.; Chatzikonstantinidis, G.; Chefdeville, M.; Chen, S.; Cheung, S.F.; Chitic, S.G.; Chobanova, V.; Chrzaszcz, M.; Chubykin, A.; Ciambrone, P.; Cid Vidal, X.; Ciezarek, G.; Clarke, P.E.L.; Clemencic, M.; Cliff, H.V.; Closier, J.; Coco, V.; Cogan, J.; Cogneras, E.; Cogoni, V.; Cojocariu, L.; Collins, P.; Colombo, T.; Comerma-Montells, A.; Contu, A.; Coombs, G.; Coquereau, S.; Corti, G.; Corvo, M.; Costa Sobral, C.M.; Couturier, B.; Cowan, G.A.; Craik, D.C.; Crocombe, A.; Cruz Torres, M.; Currie, R.; D'Ambrosio, C.; Da Cunha Marinho, F.; Da Silva, C.L.; Dall'Occo, E.; Dalseno, J.; Davis, A.; De Aguiar Francisco, O.; De Bruyn, K.; De Capua, S.; De Cian, M.; De Miranda, J.M.; De Paula, L.; De Serio, M.; De Simone, P.; Dean, C.T.; Decamp, D.; Del Buono, L.; Delaney, B.; Dembinski, H.P.; Demmer, M.; Dendek, A.; Derkach, D.; Deschamps, O.; Dettori, F.; Dey, B.; Di Canto, A.; Di Nezza, P.; Dijkstra, H.; Dordei, F.; Dorigo, M.; Suárez, A. Dosil; Douglas, L.; Dovbnya, A.; Dreimanis, K.; Dufour, L.; Dujany, G.; Durante, P.; Durham, J.M.; Dutta, D.; Dzhelyadin, R.; Dziewiecki, M.; Dziurda, A.; Dzyuba, A.; Easo, S.; Egede, U.; Egorychev, V.; Eidelman, S.; Eisenhardt, S.; Eitschberger, U.; Ekelhof, R.; Eklund, L.; Ely, S.; Ene, A.; Esen, S.; Evans, H.M.; Evans, T.; Falabella, A.; Farley, N.; Farry, S.; Fazzini, D.; Federici, L.; Fernandez, G.; Fernandez Declara, P.; Fernandez Prieto, A.; Ferrari, F.; Lopes, L. Ferreira; Ferreira Rodrigues, F.; Ferro-Luzzi, M.; Filippov, S.; Fini, R.A.; Fiorini, M.; Firlej, M.; Fitzpatrick, C.; Fiutowski, T.; Fleuret, F.; Fontana, M.; Fontanelli, F.; Forty, R.; Franco Lima, V.; Frank, M.; Frei, C.; Fu, J.; Funk, W.; Furfaro, E.; Färber, C.; Gabriel, E.; Gallas Torreira, A.; Galli, D.; Gallorini, S.; Gambetta, S.; Gandelman, M.; Gandini, P.; Gao, Y.; Garcia Martin, L.M.; Pardiñas, J. García; Garra Tico, J.; Garrido, L.; Gascon, D.; Gaspar, C.; Gavardi, L.; Gazzoni, G.; Gerick, D.; Gersabeck, E.; Gersabeck, M.; Gershon, T.; Ghez, Ph.; Gianì, S.; Gibson, V.; Girard, O.G.; Giubega, L.; Gizdov, K.; Gligorov, V.V.; Golubkov, D.; Golutvin, A.; Gomes, A.; Gorelov, I.V.; Gotti, C.; Govorkova, E.; Grabowski, J.P.; Graciani Diaz, R.; Granado Cardoso, L.A.; Graugés, E.; Graverini, E.; Graziani, G.; Grecu, A.; Greim, R.; Griffith, P.; Grillo, L.; Gruber, L.; Gruberg Cazon, B.R.; Grünberg, O.; Gushchin, E.; Guz, Yu.; Gys, T.; Göbel, C.; Hadavizadeh, T.; Hadjivasiliou, C.; Haefeli, G.; Haen, C.; Haines, S.C.; Hamilton, B.; Han, X.; Hancock, T.H.; Hansmann-Menzemer, S.; Harnew, N.; Harnew, S.T.; Hasse, C.; Hatch, M.; He, J.; Hecker, M.; Heinicke, K.; Heister, A.; Hennessy, K.; Henrard, P.; Henry, L.; van Herwijnen, E.; Heß, M.; Hicheur, A.; Hill, D.; Hopchev, P.H.; Hu, W.; Huang, W.; Huard, Z.C.; Hulsbergen, W.; Humair, T.; Hushchyn, M.; Hutchcroft, D.; Ibis, P.; Idzik, M.; Ilten, P.; Jacobsson, R.; Jalocha, J.; Jans, E.; Jawahery, A.; Jiang, F.; John, M.; Johnson, D.; Jones, C.R.; Joram, C.; Jost, B.; Jurik, N.; Kandybei, S.; Karacson, M.; Kariuki, J.M.; Karodia, S.; Kazeev, N.; Kecke, M.; Keizer, F.; Kelsey, M.; Kenzie, M.; Ketel, T.; Khairullin, E.; Khanji, B.; Khurewathanakul, C.; Kim, K.E.; Kirn, T.; Klaver, S.; Klimaszewski, K.; Klimkovich, T.; Koliiev, S.; Kolpin, M.; Kopecna, R.; Koppenburg, P.; Kosmyntseva, A.; Kotriakhova, S.; Kozeiha, M.; Kravchuk, L.; Kreps, M.; Kress, F.; Krokovny, P.; Krzemien, W.; Kucewicz, W.; Kucharczyk, M.; Kudryavtsev, V.; Kuonen, A.K.; Kvaratskheliya, T.; Lacarrere, D.; Lafferty, G.; Lai, A.; Lanfranchi, G.; Langenbruch, C.; Latham, T.; Lazzeroni, C.; Le Gac, R.; Leflat, A.; Lefrançois, J.; Lefèvre, R.; Lemaitre, F.; Leroy, O.; Lesiak, T.; Leverington, B.; Li, P.R.; Li, T.; Li, Y.; Li, Z.; Liang, X.; Likhomanenko, T.; Lindner, R.; Lionetto, F.; Lisovskyi, V.; Liu, X.; Loh, D.; Loi, A.; Longstaff, I.; Lopes, J.H.; Lucchesi, D.; Lucio Martinez, M.; Lupato, A.; Luppi, E.; Lupton, O.; Lusiani, A.; Lyu, X.; Machefert, F.; Maciuc, F.; Macko, V.; Mackowiak, P.; Maddrell-Mander, S.; Maev, O.; Maguire, K.; Maisuzenko, D.; Majewski, M.W.; Malde, S.; Malecki, B.; Malinin, A.; Maltsev, T.; Manca, G.; Mancinelli, G.; Marangotto, D.; Maratas, J.; Marchand, J.F.; Marconi, U.; Marin Benito, C.; Marinangeli, M.; Marino, P.; Marks, J.; Martellotti, G.; Martin, M.; Martinelli, M.; Martinez Santos, D.; Vidal, F. Martinez; Massafferri, A.; Matev, R.; Mathad, A.; Mathe, Z.; Matteuzzi, C.; Mauri, A.; Maurice, E.; Maurin, B.; Mazurov, A.; McCann, M.; McNab, A.; McNulty, R.; Mead, J.V.; Meadows, B.; Meaux, C.; Meier, F.; Meinert, N.; Melnychuk, D.; Merk, M.; Merli, A.; Michielin, E.; Milanes, D.A.; Millard, E.; Minard, M.N.; Minzoni, L.; Mitzel, D.S.; Mogini, A.; Molina Rodriguez, J.; Mombächer, T.; Monroy, I.A.; Monteil, S.; Morandin, M.; Morello, M.J.; Morgunova, O.; Moron, J.; Morris, A.B.; Mountain, R.; Muheim, F.; Mulder, M.; Müller, D.; Müller, J.; Müller, K.; Müller, V.; Naik, P.; Nakada, T.; Nandakumar, R.; Nandi, A.; Nasteva, I.; Needham, M.; Neri, N.; Neubert, S.; Neufeld, N.; Neuner, M.; Nguyen, T.D.; Nguyen-Mau, C.; Nieswand, S.; Niet, R.; Nikitin, N.; Nikodem, T.; Nogay, A.; O'Hanlon, D.P.; Oblakowska-Mucha, A.; Obraztsov, V.; Ogilvy, S.; Oldeman, R.; Onderwater, C.J.G.; Ossowska, A.; Otalora Goicochea, J.M.; Owen, P.; Oyanguren, A.; Pais, P.R.; Palano, A.; Palutan, M.; Panshin, G.; Papanestis, A.; Pappagallo, M.; Pappalardo, L.L.; Parker, W.; Parkes, C.; Passaleva, G.; Pastore, A.; Patel, M.; Patrignani, C.; Pearce, A.; Pellegrino, A.; Penso, G.; Pepe Altarelli, M.; Perazzini, S.; Pereima, D.; Perret, P.; Pescatore, L.; Petridis, K.; Petrolini, A.; Petrov, A.; Petruzzo, M.; Picatoste Olloqui, E.; Pietrzyk, B.; Pietrzyk, G.; Pikies, M.; Pinci, D.; Pisani, F.; Pistone, A.; Piucci, A.; Placinta, V.; Playfer, S.; Plo Casasus, M.; Polci, F.; Lener, M. Poli; Poluektov, A.; Polyakov, I.; Polycarpo, E.; Pomery, G.J.; Ponce, S.; Popov, A.; Popov, D.; Poslavskii, S.; Potterat, C.; Price, E.; Prisciandaro, J.; Prouve, C.; Pugatch, V.; Puig Navarro, A.; Pullen, H.; Punzi, G.; Qian, W.; Qin, J.; Quagliani, R.; Quintana, B.; Rachwal, B.; Rademacker, J.H.; Rama, M.; Ramos Pernas, M.; Rangel, M.S.; Raniuk, I.; Ratnikov, F.; Raven, G.; Ravonel Salzgeber, M.; Reboud, M.; Redi, F.; Reichert, S.; dos Reis, A.C.; Remon Alepuz, C.; Renaudin, V.; Ricciardi, S.; Richards, S.; Rihl, M.; Rinnert, K.; Robbe, P.; Robert, A.; Rodrigues, A.B.; Rodrigues, E.; Rodriguez Lopez, J.A.; Rogozhnikov, A.; Roiser, S.; Rollings, A.; Romanovskiy, V.; Romero Vidal, A.; Rotondo, M.; Rudolph, M.S.; Ruf, T.; Ruiz Valls, P.; Ruiz Vidal, J.; Saborido Silva, J.J.; Sadykhov, E.; Sagidova, N.; Saitta, B.; Salustino Guimaraes, V.; Sanchez Mayordomo, C.; Sanmartin Sedes, B.; Santacesaria, R.; Santamarina Rios, C.; Santimaria, M.; Santovetti, E.; Sarpis, G.; Sarti, A.; Satriano, C.; Satta, A.; Saunders, D.M.; Savrina, D.; Schael, S.; Schellenberg, M.; Schiller, M.; Schindler, H.; Schmelling, M.; Schmelzer, T.; Schmidt, B.; Schneider, O.; Schopper, A.; Schreiner, H.F.; Schubiger, M.; Schune, M.H.; Schwemmer, R.; Sciascia, B.; Sciubba, A.; Semennikov, A.; Sepulveda, E.S.; Sergi, A.; Serra, N.; Serrano, J.; Sestini, L.; Seyfert, P.; Shapkin, M.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, V.; Siddi, B.G.; Silva Coutinho, R.; Silva de Oliveira, L.; Simi, G.; Simone, S.; Skidmore, N.; Skwarnicki, T.; Smith, I.T.; Smith, J.; Smith, M.; Soares Lavra, l.; Sokoloff, M.D.; Soler, F.J.P.; Souza De Paula, B.; Spaan, B.; Spradlin, P.; Stagni, F.; Stahl, M.; Stahl, S.; Stefko, P.; Stefkova, S.; Steinkamp, O.; Stemmle, S.; Stenyakin, O.; Stepanova, M.; Stevens, H.; Stone, S.; Storaci, B.; Stracka, S.; Stramaglia, M.E.; Straticiuc, M.; Straumann, U.; Strokov, S.; Sun, J.; Sun, L.; Swientek, K.; Syropoulos, V.; Szumlak, T.; Szymanski, M.; T'Jampens, S.; Tang, Z.; Tayduganov, A.; Tekampe, T.; Tellarini, G.; Teubert, F.; Thomas, E.; van Tilburg, J.; Tilley, M.J.; Tisserand, V.; Tobin, M.; Tolk, S.; Tomassetti, L.; Tonelli, D.; Aoude, R. Tourinho Jadallah; Tournefier, E.; Traill, M.; Tran, M.T.; Tresch, M.; Trisovic, A.; Tsaregorodtsev, A.; Tsopelas, P.; Tully, A.; Tuning, N.; Ukleja, A.; Usachov, A.; Ustyuzhanin, A.; Uwer, U.; Vacca, C.; Vagner, A.; Vagnoni, V.; Valassi, A.; Valat, S.; Valenti, G.; Vazquez Gomez, R.; Regueiro, P. Vazquez; Vecchi, S.; van Veghel, M.; Velthuis, J.J.; Veltri, M.; Veneziano, G.; Venkateswaran, A.; Verlage, T.A.; Vernet, M.; Vesterinen, M.; Viana Barbosa, J.V.; Vieira, D.; Vieites Diaz, M.; Viemann, H.; Vilasis-Cardona, X.; Vitkovskiy, A.; Vitti, M.; Volkov, V.; Vollhardt, A.; Voneki, B.; Vorobyev, A.; Vorobyev, V.; Voß, C.; de Vries, J.A.; Vázquez Sierra, C.; Waldi, R.; Walsh, J.; Wang, J.; Wang, M.; Wang, Y.; Ward, D.R.; Wark, H.M.; Watson, N.K.; Websdale, D.; Weiden, A.; Weisser, C.; Whitehead, M.; Wicht, J.; Wilkinson, G.; Wilkinson, M.; Williams, M.R.J.; Williams, M.; Williams, T.; Wilson, F.F.; Wimberley, J.; Winn, M.; Wishahi, J.; Wislicki, W.; Witek, M.; Wormser, G.; Wotton, S.A.; Wyllie, K.; Xie, Y.; Xu, M.; Xu, Q.; Xu, Z.; Yang, Z.; Yao, Y.; Yin, H.; Yu, J.; Yuan, X.; Yushchenko, O.; Zarebski, K.A.; Zavertyaev, M.; Zhang, L.; Zhang, Y.; Zhelezov, A.; Zheng, Y.; Zhu, X.; Zhukov, V.; Zonneveld, J.B.; Zucchelli, S.

    A search for $C$P and $P$ violation using triple-product asymmetries is performed with $\\Lambda^{0}_{b}\\to pK^{-}\\pi^{+}\\pi^{-}$, $\\Lambda^{0}_{b}\\to pK^{-}K^{+}K^{-}$ and $\\Xi^{0}_{b}\\to pK^{-}K^{-}\\pi^{+}$ decays. The data sample corresponds to integrated luminosities of 1.0fb$^{-1}$ and 2.0fb$^{-1}$, recorded with the LHCb detector at centre-of-mass energies of 7TeV and 8TeV, respectively. The $CP$- and $P$-violating asymmetries are measured both integrating over all phase space and in specific phase-space regions. No significant deviation from $CP$ or $P$ symmetry is found.

  2. Sequential and simultaneous choices: testing the diet selection and sequential choice models.

    Science.gov (United States)

    Freidin, Esteban; Aw, Justine; Kacelnik, Alex

    2009-03-01

    We investigate simultaneous and sequential choices in starlings, using Charnov's Diet Choice Model (DCM) and Shapiro, Siller and Kacelnik's Sequential Choice Model (SCM) to integrate function and mechanism. During a training phase, starlings encountered one food-related option per trial (A, B or R) in random sequence and with equal probability. A and B delivered food rewards after programmed delays (shorter for A), while R ('rejection') moved directly to the next trial without reward. In this phase we measured latencies to respond. In a later, choice, phase, birds encountered the pairs A-B, A-R and B-R, the first implementing a simultaneous choice and the second and third sequential choices. The DCM predicts when R should be chosen to maximize intake rate, and SCM uses latencies of the training phase to predict choices between any pair of options in the choice phase. The predictions of both models coincided, and both successfully predicted the birds' preferences. The DCM does not deal with partial preferences, while the SCM does, and experimental results were strongly correlated to this model's predictions. We believe that the SCM may expose a very general mechanism of animal choice, and that its wider domain of success reflects the greater ecological significance of sequential over simultaneous choices.

  3. Advanced Mars Water Acquisition System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Mars Water Acquisition System (AMWAS) recovers and purifies water from Mars soils for oxygen and fuel production, life support, food production, and...

  4. The comparative method of language acquisition research: a Mayan case study.

    Science.gov (United States)

    Pye, Clifton; Pfeiler, Barbara

    2014-03-01

    This article demonstrates how the Comparative Method can be applied to cross-linguistic research on language acquisition. The Comparative Method provides a systematic procedure for organizing and interpreting acquisition data from different languages. The Comparative Method controls for cross-linguistic differences at all levels of the grammar and is especially useful in drawing attention to variation in contexts of use across languages. This article uses the Comparative Method to analyze the acquisition of verb suffixes in two Mayan languages: K'iche' and Yucatec. Mayan status suffixes simultaneously mark distinctions in verb transitivity, verb class, mood, and clause position. Two-year-old children acquiring K'iche' and Yucatec Maya accurately produce the status suffixes on verbs, in marked distinction to the verbal prefixes for aspect and agreement. We find evidence that the contexts of use for the suffixes differentially promote the children's production of cognate status suffixes in K'iche' and Yucatec.

  5. Sequential multipoint motion of the tympanic membrane measured by laser Doppler vibrometry: preliminary results for normal tympanic membrane.

    Science.gov (United States)

    Kunimoto, Yasuomi; Hasegawa, Kensaku; Arii, Shiro; Kataoka, Hideyuki; Yazama, Hiroaki; Kuya, Junko; Kitano, Hiroya

    2014-04-01

    Numerous studies have reported sound-induced motion of the tympanic membrane (TM). To demonstrate sequential motion characteristics of the entire TM by noncontact laser Doppler vibrometry (LDV), we have investigated multipoint TM measurement. A laser Doppler vibrometer was mounted on a surgical microscope. The velocity was measured at 33 points on the TM using noncontact LDV without any reflectors. Measurements were performed with tonal stimuli of 1, 3, and 6 kHz. Amplitudes were calculated from these measurements, and time-dependent changes in TM motion were described using a graphics application. TM motions were detected more clearly and stably at 1 and 3 kHz than at other frequencies. This is because the external auditory canal acted as a resonant tube near 3 kHz. TM motion displayed 1 peak at 1 kHz and 2 peaks at 3 kHz. Large amplitudes were detected in the posterosuperior quadrant (PSQ) at 1 kHz and in the PSQ and anteroinferior quadrant (AIQ) at 3 kHz. The entire TM showed synchronized movement centered on the PSQ at 1 kHz, with phase-shifting between PSQ and AIQ movement at 3 kHz. Amplitude was smaller at the umbo than at other parts. In contrast, amplitudes at high frequencies were too small and complicated to detect any obvious peaks. Sequential multipoint motion of the tympanic membrane showed that vibration characteristics of the TM differ according to the part and frequency.

  6. Poznámky k signalizaci argumentace v jazykové interakci

    Czech Academy of Sciences Publication Activity Database

    Kopecký, Jakub

    ročník 99, č. 1 (2016), s. 19-32 ISSN 0027-8203 R&D Projects: GA MŠk(CZ) LM2010013 Institutional support: RVO:68378092 Keywords : action formatioon * argumentation * content * conversation analysis * linguistic form * news interview * sequential position * spoken language interaction Subject RIV: AI - Linguistics

  7. Precise algorithm to generate random sequential adsorption of hard polygons at saturation

    Science.gov (United States)

    Zhang, G.

    2018-04-01

    Random sequential adsorption (RSA) is a time-dependent packing process, in which particles of certain shapes are randomly and sequentially placed into an empty space without overlap. In the infinite-time limit, the density approaches a "saturation" limit. Although this limit has attracted particular research interest, the majority of past studies could only probe this limit by extrapolation. We have previously found an algorithm to reach this limit using finite computational time for spherical particles and could thus determine the saturation density of spheres with high accuracy. In this paper, we generalize this algorithm to generate saturated RSA packings of two-dimensional polygons. We also calculate the saturation density for regular polygons of three to ten sides and obtain results that are consistent with previous, extrapolation-based studies.

  8. Measurement of CP violation in the phase space of $B^{\\pm} \\rightarrow K^{+} K^{-} \\pi^{\\pm}$ and $B^{\\pm} \\rightarrow \\pi^{+} \\pi^{-} \\pi^{\\pm}$ decays

    CERN Document Server

    Aaij, Roel; Adinolfi, Marco; Adrover, Cosme; Affolder, Anthony; Ajaltouni, Ziad; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; Anderlini, Lucio; Anderson, Jonathan; Andreassen, Rolf; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Balagura, Vladislav; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Bauer, Thomas; Bay, Aurelio; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Belogurov, Sergey; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bettler, Mar-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Bizzeti, Andrea; Bjørnstad, Pål Marius; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brambach, Tobias; van den Brand, Johannes; Bressieux, Joël; Brett, David; Britsch, Markward; Britton, Thomas; Brook, Nicholas; Brown, Henry; Bursche, Albert; Busetto, Giovanni; Buytaert, Jan; Cadeddu, Sandro; Callot, Olivier; Calvi, Marta; Calvo Gomez, Miriam; Camboni, Alessandro; Campana, Pierluigi; Campora Perez, Daniel; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carranza-Mejia, Hector; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Ciba, Krzystof; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coca, Cornelia; Coco, Victor; Cogan, Julien; Cogneras, Eric; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; David, Pascal; David, Pieter; Davis, Adam; De Bonis, Isabelle; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Di Canto, Angelo; Dijkstra, Hans; Dogaru, Marius; Donleavy, Stephanie; Dordei, Francesca; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; van Eijk, Daan; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farry, Stephen; Ferguson, Dianne; Fernandez Albor, Victor; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fitzpatrick, Conor; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; Garofoli, Justin; Garosi, Paola; Garra Tico, Jordi; Garrido, Lluis; Gaspar, Clara; Gauld, Rhorry; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, V.V.; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gorbounov, Petr; Gordon, Hamish; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; Hartmann, Thomas; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hicks, Emma; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Hunt, Philip; Huse, Torkjell; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Iakovenko, Viktor; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jans, Eddy; Jaton, Pierre; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Kaballo, Michael; Kandybei, Sergii; Kanso, Wallaa; Karacson, Matthias; Karbach, Moritz; Kenyon, Ian; Ketel, Tjeerd; Khanji, Basem; Kochebina, Olga; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Korolev, Mikhail; Kozlinskiy, Alexandr; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanciotti, Elisa; Lanfranchi, Gaia; Langenbruch, Christoph; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leo, Sabato; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Li Gioi, Luigi; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Liu, Bo; Liu, Guoming; Lohn, Stefan; Longstaff, Ian; Lopes, Jose; Lopez-March, Neus; Lu, Haiting; Lucchesi, Donatella; Luisier, Johan; Luo, Haofei; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Manca, Giulia; Mancinelli, Giampiero; Maratas, Jan; Marconi, Umberto; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martens, Aurelien; Martín Sánchez, Alexandra; Martinelli, Maurizio; Martinez Santos, Diego; Martins Tostes, Danielle; Martynov, Aleksandr; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Maurice, Emilie; Mazurov, Alexander; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Molina Rodriguez, Josue; Monteil, Stephane; Moran, Dermot; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Mountain, Raymond; Mous, Ivan; Muheim, Franz; Müller, Katharina; Muresan, Raluca; Muryn, Bogdan; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neubert, Sebastian; Neufeld, Niko; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Nicol, Michelle; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Nomerotski, Andrey; Novoselov, Alexey; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Oggero, Serena; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Orlandea, Marius; Otalora Goicochea, Juan Martin; Owen, Patrick; Oyanguren, Maria Arantza; Pal, Bilas Kanti; Palano, Antimo; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Parkes, Christopher; Parkinson, Christopher John; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrick, Glenn; Patrignani, Claudia; Pavel-Nicorescu, Carmen; Pazos Alvarez, Antonio; Pearce, Alex; Pellegrino, Antonio; Penso, Gianni; Pepe Altarelli, Monica; Perazzini, Stefano; Perez Trigo, Eliseo; Pérez-Calero Yzquierdo, Antonio; Perret, Pascal; Perrin-Terrin, Mathieu; Pescatore, Luca; Pesen, Erhan; Pessina, Gianluigi; Petridis, Konstantin; Petrolini, Alessandro; Phan, Anna; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Polok, Grzegorz; Poluektov, Anton; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Powell, Andrew; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redford, Sophie; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Alexander; Rinnert, Kurt; Rives Molina, Vincente; Roa Romero, Diego; Robbe, Patrick; Roberts, Douglas; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruffini, Fabrizio; Ruiz, Hugo; Ruiz Valls, Pablo; Sabatino, Giovanni; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sapunov, Matvey; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Savrie, Mauro; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Seco, Marcos; Semennikov, Alexander; Senderowska, Katarzyna; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Oksana; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Anthony; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Sparkes, Ailsa; Spradlin, Patrick; Stagni, Federico; Stahl, Sascha; Steinkamp, Olaf; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Straticiuc, Mihai; Straumann, Ulrich; Subbiah, Vijay Kartik; Sun, Liang; Sutcliffe, William; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szilard, Daniela; Szumlak, Tomasz; T'Jampens, Stephane; Teklishyn, Maksym; Teodorescu, Eliza; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Tran, Minh Tâm; Tresch, Marco; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; Voss, Helge; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Webber, Adam Dane; Websdale, David; Whitehead, Mark; Wicht, Jean; Wiechczynski, Jaroslaw; Wiedner, Dirk; Wiggers, Leo; Wilkinson, Guy; Williams, Matthew; Williams, Mike; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wu, Suzhi; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Feng; Zhang, Liming; Zhang, Wen Chao; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zvyagin, Alexander

    2014-01-01

    The charmless decays $B^{\\pm} \\rightarrow K^{+}K^{-}\\pi^{\\pm}$ and $B^{\\pm} \\rightarrow \\pi^{+}\\pi^{-}\\pi^{\\pm}$ are reconstructed in a data set, corresponding to an integrated luminosity of 1.0 fb$^{-1}$ of pp collisions at a center-of-mass energy of 7 TeV, collected by LHCb in 2011. The inclusive charge asymmetries of these modes are measured to be $A_{CP}(B^{\\pm} \\rightarrow K^{+}K^{-}\\pi^{\\pm}) =-0.141 \\pm 0.040 (stat) \\pm 0.018 (syst) \\pm 0.007 (J/\\psi K^{\\pm})$ and $A_{CP}(B^{\\pm} \\rightarrow \\pi^{+}\\pi^{-}\\pi^{\\pm}) = 0.117 \\pm 0.021 (stat) \\pm 0.009 (syst) \\pm 0.007 (J/\\psi K^{\\pm})$, where the third uncertainty is due to the CP asymmetry of the $B^{\\pm} \\rightarrow J/\\psi K^{\\pm}$ reference mode. In addition to the inclusive CP asymmetries, larger asymmetries are observed in localized regions of phase space.

  9. 3D - Acquisition systems - test in Chooz B nuclear plant

    International Nuclear Information System (INIS)

    Brillault, B.; Thibault, G.

    1992-06-01

    EDF needs 3D-acquisition systems to get the precise geometry of critical nuclear spaces in order to prepare computer simulations of operations in these areas. The simulations must lead to an increase of the efficiency of the operation. The acquisition of the 3-D geometry can be done using 3D-acquisition systems. To answer the needs of the Construction Division, four different systems are compared by the Research Division in Chooz B nuclear plant in order to determine the right solution for each 3D-acquisition problem

  10. Sequential Probability Ration Tests : Conservative and Robust

    NARCIS (Netherlands)

    Kleijnen, J.P.C.; Shi, Wen

    2017-01-01

    In practice, most computers generate simulation outputs sequentially, so it is attractive to analyze these outputs through sequential statistical methods such as sequential probability ratio tests (SPRTs). We investigate several SPRTs for choosing between two hypothesized values for the mean output

  11. Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hyuk; Choi, Young Hun; Cheon, Jung Eun; Lee, So Mi; Cho, Hyun Hae; Kim, Woo Sun; Kim, In One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Shin, Su Mi [SMG-SNU Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of)

    2015-06-15

    Radial k-space sampling techniques have been shown to reduce motion artifacts in adult abdominal MRI. To compare a T2-weighted radial k-space sampling MRI pulse sequence (BLADE) with standard respiratory-triggered T2-weighted turbo spin echo (TSE) in pediatric abdominal imaging. Axial BLADE and respiratory-triggered turbo spin echo sequences were performed without fat suppression in 32 abdominal MR examinations in children. We retrospectively assessed overall image quality, the presence of respiratory, peristaltic and radial artifact, and lesion conspicuity. We evaluated signal uniformity of each sequence. BLADE showed improved overall image quality (3.35 ± 0.85 vs. 2.59 ± 0.59, P < 0.001), reduced respiratory motion artifact (0.51 ± 0.56 vs. 1.89 ± 0.68, P < 0.001), and improved lesion conspicuity (3.54 ± 0.88 vs. 2.92 ± 0.77, P = 0.006) compared to respiratory triggering turbo spin-echo (TSE) sequences. The bowel motion artifact scores were similar for both sequences (1.65 ± 0.77 vs. 1.79 ± 0.74, P = 0.691). BLADE introduced a radial artifact that was not observed on the respiratory triggering-TSE images (1.10 ± 0.85 vs. 0, P < 0.001). BLADE was associated with diminished signal variation compared with respiratory triggering-TSE in the liver, spleen and air (P < 0.001). The radial k-space sampling technique improved the quality and reduced respiratory motion artifacts in young children compared with conventional respiratory-triggered turbo spin-echo sequences. (orig.)

  12. High data rate coding for the space station telemetry links.

    Science.gov (United States)

    Lumb, D. R.; Viterbi, A. J.

    1971-01-01

    Coding systems for high data rates were examined from the standpoint of potential application in space-station telemetry links. Approaches considered included convolutional codes with sequential, Viterbi, and cascaded-Viterbi decoding. It was concluded that a high-speed (40 Mbps) sequential decoding system best satisfies the requirements for the assumed growth potential and specified constraints. Trade-off studies leading to this conclusion are viewed, and some sequential (Fano) algorithm improvements are discussed, together with real-time simulation results.

  13. Sequential lineup presentation: Patterns and policy

    OpenAIRE

    Lindsay, R C L; Mansour, Jamal K; Beaudry, J L; Leach, A-M; Bertrand, M I

    2009-01-01

    Sequential lineups were offered as an alternative to the traditional simultaneous lineup. Sequential lineups reduce incorrect lineup selections; however, the accompanying loss of correct identifications has resulted in controversy regarding adoption of the technique. We discuss the procedure and research relevant to (1) the pattern of results found using sequential versus simultaneous lineups; (2) reasons (theory) for differences in witness responses; (3) two methodological issues; and (4) im...

  14. Sequential Product of Quantum Effects: An Overview

    Science.gov (United States)

    Gudder, Stan

    2010-12-01

    This article presents an overview for the theory of sequential products of quantum effects. We first summarize some of the highlights of this relatively recent field of investigation and then provide some new results. We begin by discussing sequential effect algebras which are effect algebras endowed with a sequential product satisfying certain basic conditions. We then consider sequential products of (discrete) quantum measurements. We next treat transition effect matrices (TEMs) and their associated sequential product. A TEM is a matrix whose entries are effects and whose rows form quantum measurements. We show that TEMs can be employed for the study of quantum Markov chains. Finally, we prove some new results concerning TEMs and vector densities.

  15. KENS data acquisition system KENSnet

    International Nuclear Information System (INIS)

    Arai, Masatoshi; Furusaka, Michihiro; Satoh, Setsuo; Johnson, M.W.

    1988-01-01

    The installation of a new data acquisition system KENSnet has been completed at the KENS neutron facility. For data collection, 160 Mbytes are necessary for temporary disk storage, and 1 MIPS of CPU is required. For the computing system, models were chosen from the VAX family of computers running their proprietary operating system VMS. The VMS operating system has a very user friendly interface, and is well suited to instrument control applications. New data acquisition electronics were developed. A gate module receives a signal of proton extraction time from the accelerator, and checks the veto signals from the sample environment equipment (vacuum, temperature, chopper phasing, etc.). Then the signal is issued to a delay-time module. A time-control module starts timing from the delayed start signal from the delay-time module, and distributes an encoded time-boundary address to memory modules at the preset times anabling the memory modules to accumulate data histograms. The data acquisition control program (ICP) and the general data analysis program (Genie) were both developed at ISIS, and have been installed in the new data acquisition system. They give the experimenter 'user-friendly' data acquisition and a good environment for data manipulation. The ICP controls the DAE and transfers the histogram data into the computers. (N.K.)

  16. Optimal Sequential Rules for Computer-Based Instruction.

    Science.gov (United States)

    Vos, Hans J.

    1998-01-01

    Formulates sequential rules for adapting the appropriate amount of instruction to learning needs in the context of computer-based instruction. Topics include Bayesian decision theory, threshold and linear-utility structure, psychometric model, optimal sequential number of test questions, and an empirical example of sequential instructional…

  17. Universal features in sequential and nonsequential two-photon double ionization of helium

    International Nuclear Information System (INIS)

    Pazourek, R.; Nagele, S.; Persson, E.; Burgdoerfer, J.; Feist, J.; Schneider, B. I.; Collins, L. A.

    2011-01-01

    We analyze two-photon double ionization of helium in both the nonsequential ((ℎ/2π)ω 2 ≅54.4 eV) and sequential ((ℎ/2π)ω>I 2 ) regime. We show that the energy spacing ΔE=E 1 -E 2 between the two emitted electrons provides the key parameter that controls both the energy and the angular distribution and reveals the universal features present in both the nonsequential and sequential regime. This universality, i.e., independence of (ℎ/2π)ω, is a manifestation of the continuity across the threshold for sequential double ionization. For all photon energies considered, the energy distribution can be described by a universal shape function that contains only the spectral and temporal information entering second-order time-dependent perturbation theory. Angular correlations and distributions are found to be more sensitive to the value of (ℎ/2π)ω. In particular, shake-up interferences have a large effect on the angular distribution. Energy spectra, angular distributions parametrized by the anisotropy parameters β j , and total cross sections presented in this paper are obtained by fully correlated time-dependent ab initio calculations.

  18. S-band low noise amplifier and 40 kW high power amplifier subsystems of Japanese Deep Space Earth Station

    Science.gov (United States)

    Honma, K.; Handa, K.; Akinaga, W.; Doi, M.; Matsuzaki, O.

    This paper describes the design and the performance of the S-band low noise amplifier and the S-band high power amplifier that have been developed for the Usuda Deep Space Station of the Institute of Space and Astronautical Science (ISAS), Japan. The S-band low noise amplifier consists of a helium gas-cooled parametric amplifier followed by three-stage FET amplifiers and has a noise temperature of 8 K. The high power amplifier is composed of two 28 kW klystrons, capable of transmitting 40 kW continuously when two klystrons are combined. Both subsystems are operating quite satisfactorily in the tracking of Sakigake and Suisei, the Japanese interplanetary probes for Halley's comet exploration, launched by ISAS in 1985.

  19. The Messiness of Meaning Making: Examining the Affordances of the Digital Space as a Mentoring and Tutoring Space for the Acquisition of Academic Literacy

    Directory of Open Access Journals (Sweden)

    Arend Moeain

    2017-12-01

    Full Text Available Having incorporated a digital aspect to our academic literacy course, and having monitored this over the last three years, we have come to believe that online mentoring can serve as an essential form of tutoring and mentoring. Our study is located in the field of New Literacy Studies and examines the affordances of a digital space in a first year academic literacy course in the Humanities. We focus on students’ acquisition of academic literacy, as well as critical thinking and reflexivity around a core social science concept; identity. Here, we refer to the ability to think critically and reflexively, as the ‘analytical mode’, a key driver in shaping the pedagogy of the course. In this paper, we explore the online participation of two students and how they engage with the theme of identity, not only as an academic concept but also as one intrinsically linked with how they see themselves in a diverse post-apartheid South African context. We argue that the digital space promotes a particular form of the ‘analytical mode’ as students grapple with texts and concepts on the academic literacy course. Using a qualitative case study methodology, our analysis of students’ online interaction revealed that the digital space allowed students to express themselves with a level of depth and sophistication, and to share dissident views that could not be expressed in the traditional classroom space. Furthermore, we argue that the digital space can suspend students’ urgency to agree or disagree with the arguments of authors they read. By holding students between the two positions of agreement and disagreement, we propose that the digital space becomes a space of reflexive1 discomfort which captures various moments in students’ drafting processes as they operate within the analytical mode. Therefore, we argue that the digital space, if harnessed with a particular type of mentoring philosophy and pedagogy that activates the analytical mode, can

  20. Data acquisition and control of the Zero Gradient Synchrotron 500 MeV booster synchrotron

    International Nuclear Information System (INIS)

    Timm, R.E.; Forrestal, J.; Hogrefe, R.; Voss, D.

    1977-01-01

    A data acquisition and control philosophy for the Zero Gradient Synchrotron (ZGS) 500 MeV booster has involved a top down design incorporating all of the systems comprising the booster. Consideration of operational complexity was necessary because the booster is to be used simultaneously for ZGS injection, and solid state physics studies. Existing software and hardware capabilities of the ZGS computer were considered. The resulting data acquisition and control system is based on a mix of sequential logic and a minicomputer. Hardware considerations were based on a ten year life expectancy of the booster. Due to time, budget, and manpower constraints, the incorporation of the total design has been divided into three phases of implementation. The first phase is covered and the remaining phases are outlined

  1. Gauge constructs and immersions of four-dimensional spacetimes in (4 + k)-dimensional flat spaces: algebraic evaluation of gravity fields

    International Nuclear Information System (INIS)

    Edelen, Dominic G B

    2003-01-01

    Local action of the fundamental group SO(a, 4 + k - a) is used to show that any solution of an algebraically closed differential system, that is generated from matrix Lie algebra valued 1-forms on a four-dimensional parameter space, will generate families of immersions of four-dimensional spacetimes R 4 in flat (4 + k)-dimensional spaces M 4+k with compatible signature. The algorithm is shown to work with local action of SO(a, 4 + k - a) replaced by local action of GL(4 + k). Immersions generated by local action of the Poincare group on the target spacetime are also obtained. Evaluations of the line elements, immersion loci and connection and curvature forms of these immersions are algebraic. Families of immersions that depend on one or more arbitrary functions are calculated for 1 ≤ k ≤ 4. Appropriate sections of graphs of the conformal factor for two and three interacting line singularities immersed in M 6 are given in appendix A. The local immersion theorem given in appendix B shows that all local solutions of the immersion problem are obtained by use of this method and an algebraic extension in exceptional cases

  2. Quantum Inequalities and Sequential Measurements

    International Nuclear Information System (INIS)

    Candelpergher, B.; Grandouz, T.; Rubinx, J.L.

    2011-01-01

    In this article, the peculiar context of sequential measurements is chosen in order to analyze the quantum specificity in the two most famous examples of Heisenberg and Bell inequalities: Results are found at some interesting variance with customary textbook materials, where the context of initial state re-initialization is described. A key-point of the analysis is the possibility of defining Joint Probability Distributions for sequential random variables associated to quantum operators. Within the sequential context, it is shown that Joint Probability Distributions can be defined in situations where not all of the quantum operators (corresponding to random variables) do commute two by two. (authors)

  3. Optimization, formulation, and characterization of multiflavonoids-loaded flavanosome by bulk or sequential technique.

    Science.gov (United States)

    Karthivashan, Govindarajan; Masarudin, Mas Jaffri; Kura, Aminu Umar; Abas, Faridah; Fakurazi, Sharida

    2016-01-01

    This study involves adaptation of bulk or sequential technique to load multiple flavonoids in a single phytosome, which can be termed as "flavonosome". Three widely established and therapeutically valuable flavonoids, such as quercetin (Q), kaempferol (K), and apigenin (A), were quantified in the ethyl acetate fraction of Moringa oleifera leaves extract and were commercially obtained and incorporated in a single flavonosome (QKA-phosphatidylcholine) through four different methods of synthesis - bulk (M1) and serialized (M2) co-sonication and bulk (M3) and sequential (M4) co-loading. The study also established an optimal formulation method based on screening the synthesized flavonosomes with respect to their size, charge, polydispersity index, morphology, drug-carrier interaction, antioxidant potential through in vitro 1,1-diphenyl-2-picrylhydrazyl kinetics, and cytotoxicity evaluation against human hepatoma cell line (HepaRG). Furthermore, entrapment and loading efficiency of flavonoids in the optimal flavonosome have been identified. Among the four synthesis methods, sequential loading technique has been optimized as the best method for the synthesis of QKA-phosphatidylcholine flavonosome, which revealed an average diameter of 375.93±33.61 nm, with a zeta potential of -39.07±3.55 mV, and the entrapment efficiency was >98% for all the flavonoids, whereas the drug-loading capacity of Q, K, and A was 31.63%±0.17%, 34.51%±2.07%, and 31.79%±0.01%, respectively. The in vitro 1,1-diphenyl-2-picrylhydrazyl kinetics of the flavonoids indirectly depicts the release kinetic behavior of the flavonoids from the carrier. The QKA-loaded flavonosome had no indication of toxicity toward human hepatoma cell line as shown by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide result, wherein even at the higher concentration of 200 µg/mL, the flavonosomes exert >85% of cell viability. These results suggest that sequential loading technique may be a promising

  4. Sequential unconstrained minimization algorithms for constrained optimization

    International Nuclear Information System (INIS)

    Byrne, Charles

    2008-01-01

    The problem of minimizing a function f(x):R J → R, subject to constraints on the vector variable x, occurs frequently in inverse problems. Even without constraints, finding a minimizer of f(x) may require iterative methods. We consider here a general class of iterative algorithms that find a solution to the constrained minimization problem as the limit of a sequence of vectors, each solving an unconstrained minimization problem. Our sequential unconstrained minimization algorithm (SUMMA) is an iterative procedure for constrained minimization. At the kth step we minimize the function G k (x)=f(x)+g k (x), to obtain x k . The auxiliary functions g k (x):D subset of R J → R + are nonnegative on the set D, each x k is assumed to lie within D, and the objective is to minimize the continuous function f:R J → R over x in the set C = D-bar, the closure of D. We assume that such minimizers exist, and denote one such by x-circumflex. We assume that the functions g k (x) satisfy the inequalities 0≤g k (x)≤G k-1 (x)-G k-1 (x k-1 ), for k = 2, 3, .... Using this assumption, we show that the sequence {(x k )} is decreasing and converges to f(x-circumflex). If the restriction of f(x) to D has bounded level sets, which happens if x-circumflex is unique and f(x) is closed, proper and convex, then the sequence {x k } is bounded, and f(x*)=f(x-circumflex), for any cluster point x*. Therefore, if x-circumflex is unique, x* = x-circumflex and {x k } → x-circumflex. When x-circumflex is not unique, convergence can still be obtained, in particular cases. The SUMMA includes, as particular cases, the well-known barrier- and penalty-function methods, the simultaneous multiplicative algebraic reconstruction technique (SMART), the proximal minimization algorithm of Censor and Zenios, the entropic proximal methods of Teboulle, as well as certain cases of gradient descent and the Newton–Raphson method. The proof techniques used for SUMMA can be extended to obtain related results

  5. Measurement of CP violation in the phase space of B± → K+ K- π± and B± → π+ π- π± decays.

    Science.gov (United States)

    Aaij, R; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amerio, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Andrews, J E; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Baalouch, M; Bachmann, S; Back, J J; Badalov, A; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bauer, Th; Bay, A; Beddow, J; Bedeschi, F; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Bursche, A; Busetto, G; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Castillo Garcia, L; Cattaneo, M; Cauet, Ch; Cenci, R; Charles, M; Charpentier, Ph; Cheung, S-F; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Couturier, B; Cowan, G A; Craik, D C; Cruz Torres, M; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; Davis, A; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Del Buono, L; Déléage, N; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Dijkstra, H; Dogaru, M; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Durante, P; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Falabella, A; Färber, C; Farinelli, C; Farry, S; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Giubega, L; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gorbounov, P; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Griffith, P; Grillo, L; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hamilton, B; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Hartmann, T; He, J; Head, T; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Heß, M; Hicheur, A; Hicks, E; Hill, D; Hoballah, M; Hombach, C; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jans, E; Jaton, P; Jawahery, A; Jing, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Kaballo, M; Kandybei, S; Kanso, W; Karacson, M; Karbach, T M; Kenyon, I R; Ketel, T; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kurek, K; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leo, S; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lohn, S; Longstaff, I; Lopes, J H; Lopez-March, N; Lu, H; Lucchesi, D; Luisier, J; Luo, H; Lupton, O; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Maratas, J; Marconi, U; Marino, P; Märki, R; Marks, J; Martellotti, G; Martens, A; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Martynov, A; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Maurice, E; Mazurov, A; McCarthy, J; McNab, A; McNulty, R; McSkelly, B; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M-N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mordà, A; Morello, M J; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neubert, S; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pal, B K; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pearce, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pescatore, L; Pesen, E; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, A; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Rachwal, B; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reichert, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Roberts, D A; Rodrigues, A B; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rotondo, M; Rouvinet, J; Ruf, T; Ruffini, F; Ruiz, H; Ruiz Valls, P; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salustino Guimaraes, V; Sanmartin Sedes, B; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M-H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Sirendi, M; Skidmore, N; Skwarnicki, T; Smith, N A; Smith, E; Smith, E; Smith, J; Smith, M; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stevenson, S; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Sun, L; Sutcliffe, W; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szilard, D; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Ustyuzhanin, A; Uwer, U; Vagnoni, V; Valenti, G; Vallier, A; Vazquez Gomez, R; Vazquez Regueiro, P; Vázquez Sierra, C; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, C; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiechczynski, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wimberley, J; Wishahi, J; Wislicki, W; Witek, M; Wormser, G; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, Z; Yang, Z; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2014-01-10

    The charmless decays B± → K+ K- π± and B± → π+ π- π± are reconstructed in a data set of pp collisions with an integrated luminosity of 1.0  fb(-1) and center-of-mass energy of 7 TeV, collected by LHCb in 2011. The inclusive charge asymmetries of these modes are measured to be A(CP)(B± → K+ K- π±) = -0.141±0.040  (stat)±0.018 (syst)±0.007(J/ψ K±) and A(CP)(B± → π+ π- π±) = 0.117±0.021 (stat)±0.009 (syst)±0.007(J/ψ K±), where the third uncertainty is due to the CP asymmetry of the B± → J/ψK± reference mode. In addition to the inclusive CP asymmetries, larger asymmetries are observed in localized regions of phase space.

  6. Comparative efficacy of simultaneous versus sequential multiple health behavior change interventions among adults: A systematic review of randomised trials.

    Science.gov (United States)

    James, Erica; Freund, Megan; Booth, Angela; Duncan, Mitch J; Johnson, Natalie; Short, Camille E; Wolfenden, Luke; Stacey, Fiona G; Kay-Lambkin, Frances; Vandelanotte, Corneel

    2016-08-01

    Growing evidence points to the benefits of addressing multiple health behaviors rather than single behaviors. This review evaluates the relative effectiveness of simultaneous and sequentially delivered multiple health behavior change (MHBC) interventions. Secondary aims were to identify: a) the most effective spacing of sequentially delivered components; b) differences in efficacy of MHBC interventions for adoption/cessation behaviors and lifestyle/addictive behaviors, and; c) differences in trial retention between simultaneously and sequentially delivered interventions. MHBC intervention trials published up to October 2015 were identified through a systematic search. Eligible trials were randomised controlled trials that directly compared simultaneous and sequential delivery of a MHBC intervention. A narrative synthesis was undertaken. Six trials met the inclusion criteria and across these trials the behaviors targeted were smoking, diet, physical activity, and alcohol consumption. Three trials reported a difference in intervention effect between a sequential and simultaneous approach in at least one behavioral outcome. Of these, two trials favoured a sequential approach on smoking. One trial favoured a simultaneous approach on fat intake. There was no difference in retention between sequential and simultaneous approaches. There is limited evidence regarding the relative effectiveness of sequential and simultaneous approaches. Given only three of the six trials observed a difference in intervention effectiveness for one health behavior outcome, and the relatively consistent finding that the sequential and simultaneous approaches were more effective than a usual/minimal care control condition, it appears that both approaches should be considered equally efficacious. PROSPERO registration number: CRD42015027876. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Effects of simultaneous and optimized sequential cardiac resynchronization therapy on myocardial oxidative metabolism and efficiency.

    Science.gov (United States)

    Christenson, Stuart D; Chareonthaitawee, Panithaya; Burnes, John E; Hill, Michael R S; Kemp, Brad J; Khandheria, Bijoy K; Hayes, David L; Gibbons, Raymond J

    2008-02-01

    Cardiac resynchronization therapy (CRT) can improve left ventricular (LV) hemodynamics and function. Recent data suggest the energy cost of such improvement is favorable. The effects of sequential CRT on myocardial oxidative metabolism (MVO(2)) and efficiency have not been previously assessed. Eight patients with NYHA class III heart failure were studied 196 +/- 180 days after CRT implant. Dynamic [(11)C]acetate positron emission tomography (PET) and echocardiography were performed after 1 hour of: 1) AAI pacing, 2) simultaneous CRT, and 3) sequential CRT. MVO(2) was calculated using the monoexponential clearance rate of [(11)C]acetate (k(mono)). Myocardial efficiency was expressed in terms of the work metabolic index (WMI). P values represent overall significance from repeated measures analysis. Global LV and right ventricular (RV) MVO(2) were not significantly different between pacing modes, but the septal/lateral MVO(2) ratio differed significantly with the change in pacing mode (AAI pacing = 0.696 +/- 0.094 min(-1), simultaneous CRT = 0.975 +/- 0.143 min(-1), and sequential CRT = 0.938 +/- 0.189 min(-1); overall P = 0.001). Stroke volume index (SVI) (AAI pacing = 26.7 +/- 10.4 mL/m(2), simultaneous CRT = 30.6 +/- 11.2 mL/m(2), sequential CRT = 33.5 +/- 12.2 mL/m(2); overall P simultaneous CRT = 4.29 +/- 1.72 mmHg*mL/m(2)*10(6), sequential CRT = 4.79 +/- 1.92 mmHg*mL/m(2)*10(6); overall P = 0.002) also differed between pacing modes. Compared with simultaneous CRT, additional changes in septal/lateral MVO(2), SVI, and WMI with sequential CRT were not statistically significant on post hoc analysis. In this small selected population, CRT increases LV SVI without increasing MVO(2), resulting in improved myocardial efficiency. Additional improvements in LV work, oxidative metabolism, and efficiency from simultaneous to sequential CRT were not significant.

  8. Random and cooperative sequential adsorption

    Science.gov (United States)

    Evans, J. W.

    1993-10-01

    Irreversible random sequential adsorption (RSA) on lattices, and continuum "car parking" analogues, have long received attention as models for reactions on polymer chains, chemisorption on single-crystal surfaces, adsorption in colloidal systems, and solid state transformations. Cooperative generalizations of these models (CSA) are sometimes more appropriate, and can exhibit richer kinetics and spatial structure, e.g., autocatalysis and clustering. The distribution of filled or transformed sites in RSA and CSA is not described by an equilibrium Gibbs measure. This is the case even for the saturation "jammed" state of models where the lattice or space cannot fill completely. However exact analysis is often possible in one dimension, and a variety of powerful analytic methods have been developed for higher dimensional models. Here we review the detailed understanding of asymptotic kinetics, spatial correlations, percolative structure, etc., which is emerging for these far-from-equilibrium processes.

  9. Multibit CkNOT quantum gates via Rydberg blockade

    DEFF Research Database (Denmark)

    Isenhower, L.; Saffman, Mark; Mølmer, Klaus

    2011-01-01

    Long range Rydberg blockade interactions have the potential for efficient implementation of quantum gates between multiple atoms. Here we present and analyze a protocol for implementation of a k-atom controlled NOT (CkNOT) neutral atom gate. This gate can be implemented using sequential or simult......Long range Rydberg blockade interactions have the potential for efficient implementation of quantum gates between multiple atoms. Here we present and analyze a protocol for implementation of a k-atom controlled NOT (CkNOT) neutral atom gate. This gate can be implemented using sequential...... or simultaneous addressing of the control atoms which requires only 2k + 3 or 5 Rydberg π pulses respectively. A detailed error analysis relevant for implementations based on alkali atom Rydberg states is provided which shows that gate errors less than 10% are possible for k = 35....

  10. Application of Multi-Hypothesis Sequential Monte Carlo for Breakup Analysis

    Science.gov (United States)

    Faber, W. R.; Zaidi, W.; Hussein, I. I.; Roscoe, C. W. T.; Wilkins, M. P.; Schumacher, P. W., Jr.

    As more objects are launched into space, the potential for breakup events and space object collisions is ever increasing. These events create large clouds of debris that are extremely hazardous to space operations. Providing timely, accurate, and statistically meaningful Space Situational Awareness (SSA) data is crucial in order to protect assets and operations in space. The space object tracking problem, in general, is nonlinear in both state dynamics and observations, making it ill-suited to linear filtering techniques such as the Kalman filter. Additionally, given the multi-object, multi-scenario nature of the problem, space situational awareness requires multi-hypothesis tracking and management that is combinatorially challenging in nature. In practice, it is often seen that assumptions of underlying linearity and/or Gaussianity are used to provide tractable solutions to the multiple space object tracking problem. However, these assumptions are, at times, detrimental to tracking data and provide statistically inconsistent solutions. This paper details a tractable solution to the multiple space object tracking problem applicable to space object breakup events. Within this solution, simplifying assumptions of the underlying probability density function are relaxed and heuristic methods for hypothesis management are avoided. This is done by implementing Sequential Monte Carlo (SMC) methods for both nonlinear filtering as well as hypothesis management. This goal of this paper is to detail the solution and use it as a platform to discuss computational limitations that hinder proper analysis of large breakup events.

  11. K-homology and K-cohomology constructions of relations

    International Nuclear Information System (INIS)

    Abd El-Sattar, A. Dabbour; Bayoumy, F.M.

    1990-08-01

    One of the important homology (cohomology) theories, based on systems of covering of the space, is the homology (cohomology) theory of relations. In the present work, by using the idea of K-homology and K-cohomology groups different varieties of the Dowker's theory are introduced and studied. These constructions are defined on the category of pairs of topological spaces and over a pair of coefficient groups. (author). 14 refs

  12. A Double Dwell High Sensitivity GPS Acquisition Scheme Using Binarized Convolution Neural Network

    Directory of Open Access Journals (Sweden)

    Zhen Wang

    2018-05-01

    Full Text Available Conventional GPS acquisition methods, such as Max selection and threshold crossing (MAX/TC, estimate GPS code/Doppler by its correlation peak. Different from MAX/TC, a multi-layer binarized convolution neural network (BCNN is proposed to recognize the GPS acquisition correlation envelope in this article. The proposed method is a double dwell acquisition in which a short integration is adopted in the first dwell and a long integration is applied in the second one. To reduce the search space for parameters, BCNN detects the possible envelope which contains the auto-correlation peak in the first dwell to compress the initial search space to 1/1023. Although there is a long integration in the second dwell, the acquisition computation overhead is still low due to the compressed search space. Comprehensively, the total computation overhead of the proposed method is only 1/5 of conventional ones. Experiments show that the proposed double dwell/correlation envelope identification (DD/CEI neural network achieves 2 dB improvement when compared with the MAX/TC under the same specification.

  13. Scaling of Elliptic Flow, Recombination and Sequential Freeze-Out of Hadrons in Heavy-Ion Collisions

    Energy Technology Data Exchange (ETDEWEB)

    Fries, R.; He, M., and Rapp, R.

    2010-09-21

    The scaling properties of elliptic flow of hadrons produced in ultrarelativistic heavy-ion collisions are investigated at low transverse momenta, p{sub T} {le} 2 GeV. Utilizing empirical parametrizations of a thermalized fireball with collective-flow fields, the resonance recombination model (RRM) is employed to describe hadronization via quark coalescence at the hadronization transition. We reconfirm that RRM converts equilibrium quark distribution functions into equilibrated hadron spectra including the effects of space-momentum correlations on elliptic flow. This provides the basis for a controlled extraction of quark distributions of the bulk matter at hadronization from spectra of multistrange hadrons which are believed to decouple close to the critical temperature. The resulting elliptic flow from empirical fits at the BNL Relativistic Heavy Ion Collider exhibits transverse kinetic-energy and valence-quark scaling. Utilizing the well-established concept of sequential freeze-out, the scaling at low momenta extends to bulk hadrons ({pi}, K, p) at thermal freeze-out, albeit with different source parameters compared to chemical freeze-out. Elliptic-flow scaling is thus compatible with both equilibrium hydrodynamics and quark recombination.

  14. Five channel data acquisition system for tracer studies

    International Nuclear Information System (INIS)

    Narender Reddy, J.; Dhananjay Reddy, Y.; Dheeraj Reddy, J.

    2001-01-01

    Radioactive tracers are being used by many modern industries for trouble shooting, process control/quality control and optimization in the process plants. A five channel data acquisition system which has five independent scintillation detector based channels for data acquisition has been developed and made available. This system can be used for tracer studies involving Mean residence time, Resident time distribution and other similar parameters involving tracer movement. System developed can acquire data with dwell times ranging from 10 m sec to 100 sec into each channel and has a capacity to acquire data into 10K channels. Each channel electronics, has a 1x1 NaI Scintillation Detector probe, HV, AMP SCA, micro-controller based data acquisition card with independent dot matrix LCD display for visualization. Extensive use of serial bus (I 2 C, microwire) compatible devices has been incorporated in the design. Data acquisition is initiated simultaneously into all the channels. System design permits delayed/prompt data acquisition selectively. Dual counter switching technique has been employed to achieve faster dwell times for data acquisition. (author)

  15. Energy-filtered real- and k-space secondary and energy-loss electron imaging with Dual Emission Electron spectro-Microscope: Cs/Mo(110)

    Energy Technology Data Exchange (ETDEWEB)

    Grzelakowski, Krzysztof P., E-mail: k.grzelakowski@opticon-nanotechnology.com

    2016-05-15

    Since its introduction the importance of complementary k{sub ||}-space (LEED) and real space (LEEM) information in the investigation of surface science phenomena has been widely demonstrated over the last five decades. In this paper we report the application of a novel kind of electron spectromicroscope Dual Emission Electron spectroMicroscope (DEEM) with two independent electron optical channels for reciprocal and real space quasi-simultaneous imaging in investigation of a Cs covered Mo(110) single crystal by using the 800 eV electron beam from an “in-lens” electron gun system developed for the sample illumination. With the DEEM spectromicroscope it is possible to observe dynamic, irreversible processes at surfaces in the energy-filtered real space and in the corresponding energy-filtered k{sub ǁ}-space quasi-simultaneously in two independent imaging columns. The novel concept of the high energy electron beam sample illumination in the cathode lens based microscopes allows chemically selective imaging and analysis under laboratory conditions. - Highlights: • A novel concept of the electron sample illumination with “in-lens” e- gun is realized. • Quasi-simultaneous energy selective observation of the real- and k-space in EELS mode. • Observation of the energy filtered Auger electron diffraction at Cs atoms on Mo(110). • Energy-loss, Auger and secondary electron momentum microscopy is realized.

  16. Test of PPV and kVp magnitudes using a non invasive voltage test aiming an improvement on the measurement acquisition; Testes das grandezas PPV e kVp utilizando um medidor de tensao nao invasivo visando um aperfeicoamento na aquisicao de medidas

    Energy Technology Data Exchange (ETDEWEB)

    Lucena, Rodrigo F. de; Dias, Daniel M.; Franciscatto, Priscila C.; Correa, Eduardo de L.; Vivolo, Vitor; Potiens, Maria da Penha A., E-mail: rodrigoifusp@yahoo.com.b, E-mail: dmdias@ipen.b, E-mail: pfranciscatto@yahoo.com.b, E-mail: edu1905@gmail.co, E-mail: vivolo@ipen.b, E-mail: mppalbu@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    In this work the measurements of PPV (Practical Peak Voltage) and kVp (Peak Voltage) were studied obtained by use of voltage non invasive, under different conditions, viewing an improvement on the acquisition measurements at the Instrument Calibration Laboratory of the IPEN, Sao Paulo, Brazil, for the implantation of the radiation quality required for the required calibrations for X radiation instruments

  17. Status of CEA reactor studies for a 200 kWe turboelectric Space Power System

    International Nuclear Information System (INIS)

    Carre, F.; Gervaise, F.; Proust, E.; Schwartz, J.P.; Tilliette, Z.; Vrillon, B.

    1986-01-01

    A reference design for a 200 kWe Space Nuclear Power System has been developed by the CNES and CEA Agencies of the French Government in order to assess within a first study phase running from mid 1984 to mid 1986, the key feasibility issues and the development cost of a Space Power System compatible with the version of the European launcher (ARIANE V), that will be available after 1995, and with adequate power range and lifetime performances for the missions considered at that time. The heat from a fast spectrum lithium cooled reactor is converted by a turboelectric system, selected for its technological readiness and for its advantage over thermionics and thermoelectricity, of minimizing the total mass of 100 to 300 kWe power systems, considering the available radiator area afforded by the specific ARIANE V geometrical features. A heat pipe radiator is preferred to an equivalent gas cooled system, for the increased reliability brought by the large number of independent cooling elements. The successive topics addressed in the paper, include a description of the system main components and steady state operating conditions, and the present views about the start up procedure and the reactor control

  18. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis; Paaske, Erik

    1998-01-01

    We describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon (RS) codes with nonuniform profile. With this scheme decoding with good performance is possible as low...... as Eb/N0=0.6 dB, which is about 1.25 dB below the signal-to-noise ratio (SNR) that marks the cutoff rate for the full system. Accounting for about 0.45 dB due to the outer codes, sequential decoding takes place at about 1.7 dB below the SNR cutoff rate for the convolutional code. This is possible since...... the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability of computational overflow. Analytical results for the probability that the first RS word is decoded after C computations are presented. These results are supported...

  19. Aircraft Nodal Data Acquisition System (ANDAS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Development of an Aircraft Nodal Data Acquisition System (ANDAS) based upon the short haul Zigbee networking standard is proposed. It employs a very thin (135 um)...

  20. Sequential probability ratio controllers for safeguards radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.L.; Nixon, K.V.

    1984-01-01

    Sequential hypothesis tests applied to nuclear safeguards accounting methods make the methods more sensitive to detecting diversion. The sequential tests also improve transient signal detection in safeguards radiation monitors. This paper describes three microprocessor control units with sequential probability-ratio tests for detecting transient increases in radiation intensity. The control units are designed for three specific applications: low-intensity monitoring with Poisson probability ratios, higher intensity gamma-ray monitoring where fixed counting intervals are shortened by sequential testing, and monitoring moving traffic where the sequential technique responds to variable-duration signals. The fixed-interval controller shortens a customary 50-s monitoring time to an average of 18 s, making the monitoring delay less bothersome. The controller for monitoring moving vehicles benefits from the sequential technique by maintaining more than half its sensitivity when the normal passage speed doubles

  1. Biased lineups: sequential presentation reduces the problem.

    Science.gov (United States)

    Lindsay, R C; Lea, J A; Nosworthy, G J; Fulford, J A; Hector, J; LeVan, V; Seabrook, C

    1991-12-01

    Biased lineups have been shown to increase significantly false, but not correct, identification rates (Lindsay, Wallbridge, & Drennan, 1987; Lindsay & Wells, 1980; Malpass & Devine, 1981). Lindsay and Wells (1985) found that sequential lineup presentation reduced false identification rates, presumably by reducing reliance on relative judgment processes. Five staged-crime experiments were conducted to examine the effect of lineup biases and sequential presentation on eyewitness recognition accuracy. Sequential lineup presentation significantly reduced false identification rates from fair lineups as well as from lineups biased with regard to foil similarity, instructions, or witness attire, and from lineups biased in all of these ways. The results support recommendations that police present lineups sequentially.

  2. Confirmatory Analysis of Simultaneous, Sequential, and Achievement Factors on the K-ABC at 11 Age Levels Ranging from 2 1/2 to 12 1/2 years.

    Science.gov (United States)

    Willson, Victor L.; And Others

    1985-01-01

    Presents results of confirmatory factor analysis of the Kaufman Assessment Battery for children which is based on the underlying theoretical model of sequential, simultaneous, and achievement factors. Found support for the two-factor, simultaneous and sequential processing model. (MCF)

  3. The Telecommunications and Data Acquisition Report

    Science.gov (United States)

    Yuen, Joseph H. (Editor)

    1996-01-01

    This quarterly publication provides archival reports on developments in programs managed by JPL's Telecommunications and Mission Operations Directorate (TMOD), which now includes the former Telecommunications and Data Acquisition (TDA) Office. In space communications, radio navigation, radio science, and ground-based radio and radar astronomy, it reports on activities of the Deep Space Network (DSN) in planning, supporting research and technology, implementation, and operations. Also included are standards activity at JPL for space data and information systems and reimbursable DSN work performed for other space agencies through NASA. The preceding work is all performed for NASA's Office of Space Communications (OSC). TMOD also performs work funded by other NASA program offices through and with the cooperation of OSC. The first of these is the Orbital Debris Radar Program funded by the Office of Space Systems Development. It exists at Goldstone only and makes use of the planetary radar capability when the antennas are configured as science instruments making direct observations of the planets, their satellites, and asteroids of our solar system. The Office of Space Sciences funds the data reduction and science analyses of data obtained by the Goldstone Solar System Radar. The antennas at all three complexes are also configured for radio astronomy research and, as such, conduct experiments funded by the National Science Foundation in the U.S. and other agencies at the overseas complexes. These experiments are either in microwave spectroscopy or very long baseline interferometry. Finally, tasks funded under the JPL Director's Discretionary Fund and the Caltech President's Fund that involve TMOD are included. This and each succeeding issue of 'The Telecommunications and Data Acquisition Progress Report' will present material in some, but not necessarily all, of the aforementioned programs.

  4. Lineup composition, suspect position, and the sequential lineup advantage.

    Science.gov (United States)

    Carlson, Curt A; Gronlund, Scott D; Clark, Steven E

    2008-06-01

    N. M. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001) argued that sequential lineups reduce the likelihood of mistaken eyewitness identification. Experiment 1 replicated the design of R. C. L. Lindsay and G. L. Wells (1985), the first study to show the sequential lineup advantage. However, the innocent suspect was chosen at a lower rate in the simultaneous lineup, and no sequential lineup advantage was found. This led the authors to hypothesize that protection from a sequential lineup might emerge only when an innocent suspect stands out from the other lineup members. In Experiment 2, participants viewed a simultaneous or sequential lineup with either the guilty suspect or 1 of 3 innocent suspects. Lineup fairness was varied to influence the degree to which a suspect stood out. A sequential lineup advantage was found only for the unfair lineups. Additional analyses of suspect position in the sequential lineups showed an increase in the diagnosticity of suspect identifications as the suspect was placed later in the sequential lineup. These results suggest that the sequential lineup advantage is dependent on lineup composition and suspect position. (c) 2008 APA, all rights reserved

  5. Patient-adapted reconstruction and acquisition dynamic imaging method (PARADIGM) for MRI

    International Nuclear Information System (INIS)

    Aggarwal, Nitin; Bresler, Yoram

    2008-01-01

    Dynamic magnetic resonance imaging (MRI) is a challenging problem because the MR data acquisition is often not fast enough to meet the combined spatial and temporal Nyquist sampling rate requirements. Current approaches to this problem include hardware-based acceleration of the acquisition, and model-based image reconstruction techniques. In this paper we propose an alternative approach, called PARADIGM, which adapts both the acquisition and reconstruction to the spatio-temporal characteristics of the imaged object. The approach is based on time-sequential sampling theory, addressing the problem of acquiring a spatio-temporal signal under the constraint that only a limited amount of data can be acquired at a time instant. PARADIGM identifies a model class for the particular imaged object using a scout MR scan or auxiliary data. This object-adapted model is then used to optimize MR data acquisition, such that the imaging constraints are met, acquisition speed requirements are minimized, essentially perfect reconstruction of any object in the model class is guaranteed, and the inverse problem of reconstructing the dynamic object has a condition number of one. We describe spatio-temporal object models for various dynamic imaging applications including cardiac imaging. We present the theory underlying PARADIGM and analyze its performance theoretically and numerically. We also propose a practical MR imaging scheme for 2D dynamic cardiac imaging based on the theory. For this application, PARADIGM is predicted to provide a 10–25 × acceleration compared to the optimal non-adaptive scheme. Finally we present generalized optimality criteria and extend the scheme to dynamic imaging with three spatial dimensions

  6. High Frontier: The Journal for Space and Cyberspace Professionals. Volume 6, Number 4, August 2010

    Science.gov (United States)

    2010-08-01

    much persistence as our enemies. Notes: 1 The Cyber Kill Chain and the concept that an unbroken sequential chain of events for success was conceived by...and contracting were well represented. Soon after the teams formed with their impressive lineups , they practiced their acquisition skills. In

  7. Advanced data acquisition system for SEVAN

    Science.gov (United States)

    Chilingaryan, Suren; Chilingarian, Ashot; Danielyan, Varuzhan; Eppler, Wolfgang

    2009-02-01

    Huge magnetic clouds of plasma emitted by the Sun dominate intense geomagnetic storm occurrences and simultaneously they are correlated with variations of spectra of particles and nuclei in the interplanetary space, ranging from subtermal solar wind ions till GeV energy galactic cosmic rays. For a reliable and fast forecast of Space Weather world-wide networks of particle detectors are operated at different latitudes, longitudes, and altitudes. Based on a new type of hybrid particle detector developed in the context of the International Heliophysical Year (IHY 2007) at Aragats Space Environmental Center (ASEC) we start to prepare hardware and software for the first sites of Space Environmental Viewing and Analysis Network (SEVAN). In the paper the architecture of the newly developed data acquisition system for SEVAN is presented. We plan to run the SEVAN network under one-and-the-same data acquisition system, enabling fast integration of data for on-line analysis of Solar Flare Events. An Advanced Data Acquisition System (ADAS) is designed as a distributed network of uniform components connected by Web Services. Its main component is Unified Readout and Control Server (URCS) which controls the underlying electronics by means of detector specific drivers and makes a preliminary analysis of the on-line data. The lower level components of URCS are implemented in C and a fast binary representation is used for the data exchange with electronics. However, after preprocessing, the data are converted to a self-describing hybrid XML/Binary format. To achieve better reliability all URCS are running on embedded computers without disk and fans to avoid the limited lifetime of moving mechanical parts. The data storage is carried out by means of high performance servers working in parallel to provide data security. These servers are periodically inquiring the data from all URCS and storing it in a MySQL database. The implementation of the control interface is based on high level

  8. Strategy BMT Al-Ittihad Using Matrix IE, Matrix SWOT 8K, Matrix SPACE and Matrix TWOS

    Directory of Open Access Journals (Sweden)

    Nofrizal Nofrizal

    2018-03-01

    Full Text Available This research aims to formulate and select BMT Al-Ittihad Rumbai strategy to face the changing of business environment both from internal environment such as organization resources, finance, member and external business such as competitor, economy, politics and others. This research method used Analysis of EFAS, IFAS, IE Matrix, SWOT-8K Matrix, SPACE Matrix and TWOS Matrix. our hope from this research it can assist BMT Al-Ittihad in formulating and selecting strategies for the sustainability of BMT Al-Ittihad in the future. The sample in this research is using purposive sampling technique that is the manager and leader of BMT Al-IttihadRumbaiPekanbaru. The result of this research shows that the position of BMT Al-Ittihad using IE Matrix, SWOT-8K Matrix and SPACE Matrix is in growth position, stabilization and aggressive. The choice of strategy after using TWOS Matrix is market penetration, market development, vertical integration, horizontal integration, and stabilization (careful.

  9. Continuous and real-time data acquisition system for superconducting tokamaks HT-7 and TRIAM-1M

    International Nuclear Information System (INIS)

    Wang, F.; Luo, J.R.; Nakamura, K.; Sato, K.N.; Hanada, K.; Sakamoto, M.; Idei, H.; Kawasaki, S.; Nakashima, H.

    2006-01-01

    Conventional data acquisition systems cannot deal with data acquisition for a long-time discharge of a nuclear fusion reactor. Thus, continuous data acquisition with a real-time data presentation during discharge must be developed. Two data acquisition systems, which include alternating CAMAC data acquisition and long-time PCI data acquisition, are designed for the long-time operation of HT-7 tokamak. Since an effective alternating mode is adopted, the alternating CAMAC data acquisition can accurately and continuously acquire data at a rate of 10 kHz. The acquired data is immediately transmitted to a data server and real-time results can be presented during the plasma discharge. As for the long-time PCI data acquisition, a special kind of PCI A/D card, which has a hard disk on board, is designed to collect data at a max speed of 200 kHz. Thus, the total sampling duration is only related to the capacity of the hard disk on board. These two types of data acquisitions were applied to HT-7 tokamak and a 250 s discharge was acquired. These data acquisition systems were also successfully demonstrated on a 2500 s plasma discharge on TRIAM-1M. This paper describes the two data acquisitions in detail

  10. Magnetic-Field-Response Measurement-Acquisition System

    Science.gov (United States)

    Woodward, Stanley E.; Shams, Qamar A.; Fox, Robert L.; Taylor, Bryant D.

    2006-01-01

    A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a

  11. Tradable permit allocations and sequential choice

    Energy Technology Data Exchange (ETDEWEB)

    MacKenzie, Ian A. [Centre for Economic Research, ETH Zuerich, Zurichbergstrasse 18, 8092 Zuerich (Switzerland)

    2011-01-15

    This paper investigates initial allocation choices in an international tradable pollution permit market. For two sovereign governments, we compare allocation choices that are either simultaneously or sequentially announced. We show sequential allocation announcements result in higher (lower) aggregate emissions when announcements are strategic substitutes (complements). Whether allocation announcements are strategic substitutes or complements depends on the relationship between the follower's damage function and governments' abatement costs. When the marginal damage function is relatively steep (flat), allocation announcements are strategic substitutes (complements). For quadratic abatement costs and damages, sequential announcements provide a higher level of aggregate emissions. (author)

  12. Single, simultaneous and sequential applications of ultrasonic frequencies for the elimination of ibuprofen in water.

    Science.gov (United States)

    Ziylan-Yavas, Asu; Ince, Nilsun H

    2018-01-01

    The study is about the assessment of single and multi-frequency operations for the overall degradation of a widely consumed analgesic pharmaceutical-ibuprofen (IBP). The selected frequencies were in the range of 20-1130kHz emissions coming from probes, baths and piezo-electric transducers attached to plate-type devices. Multi-frequency operations were applied either simultaneously as "duals", or sequentially at fixed time intervals; and the total reaction time in all operations was 30-min. The work also covers evaluation of the effect of zero-valent iron (ZVI) on the efficiency of the degradation process and the performance of the reaction systems. It was found that low-frequency probe type devices especially at 20kHz were ineffective when applied singly and without ZVI, and relatively more effective in combined-frequency operations in the presence of ZVI. The power efficiencies of the reactors and/or reaction systems showed that 20-kHz probe was considerably more energy intensive than all others, and was therefore not used in multi-frequency operations. The most efficient reactor in terms of power consumption was the bath (200kHz), which however provided insufficient mineralization of the test chemical. The highest percentage of TOC decay (37%) was obtained in a dual-frequency operation (40/572kHz) with ZVI, in which the energy consumption was neither low nor exceptionally too high. A sequential operation (40+200kHz) in that respect was more efficient, because it required much less energy for a similar TOC decay performance (30%). In general, the degradation of IBP increased with increased power consumption, which in turn reduced the sonochemical yield. The study also showed that advanced Fenton reactions with ZVI were faster in the presence of ultrasound, and the metal was very effective in improving the performance of low-frequency operations. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Grasp Algorithms For Optotactile Robotic Sample Acquisition, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Robotic sample acquisition is basically grasping. Multi-finger robot sample grasping devices are controlled to securely pick up samples. While optimal grasps for...

  14. Broadband Wireless Data Acquisition and Control Device, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Mobitrum is proposing to develop a broadband wireless device for real-time data acquisition and monitoring applicable to the field instrumentation and control...

  15. Building Space Management | Climate Neutral Research Campuses | NREL

    Science.gov (United States)

    , repurposing underused space and through the use of electronic media. Several space management principles can Building Space Management Building Space Management Building space represents one of the largest recruiting and successful acquisition of research funding. Learn more about how space management is necessary

  16. White blood cell segmentation by color-space-based k-means clustering.

    Science.gov (United States)

    Zhang, Congcong; Xiao, Xiaoyan; Li, Xiaomei; Chen, Ying-Jie; Zhen, Wu; Chang, Jun; Zheng, Chengyun; Liu, Zhi

    2014-09-01

    White blood cell (WBC) segmentation, which is important for cytometry, is a challenging issue because of the morphological diversity of WBCs and the complex and uncertain background of blood smear images. This paper proposes a novel method for the nucleus and cytoplasm segmentation of WBCs for cytometry. A color adjustment step was also introduced before segmentation. Color space decomposition and k-means clustering were combined for segmentation. A database including 300 microscopic blood smear images were used to evaluate the performance of our method. The proposed segmentation method achieves 95.7% and 91.3% overall accuracy for nucleus segmentation and cytoplasm segmentation, respectively. Experimental results demonstrate that the proposed method can segment WBCs effectively with high accuracy.

  17. Bumblebees exhibit the memory spacing effect

    Science.gov (United States)

    Toda, Nicholas R. T.; Song, Jeremy; Nieh, James C.

    2009-10-01

    Associative learning is key to how bees recognize and return to rewarding floral resources. It thus plays a major role in pollinator floral constancy and plant gene flow. Honeybees are the primary model for pollinator associative learning, but bumblebees play an important ecological role in a wider range of habitats, and their associative learning abilities are less well understood. We assayed learning with the proboscis extension reflex (PER), using a novel method for restraining bees (capsules) designed to improve bumblebee learning. We present the first results demonstrating that bumblebees exhibit the memory spacing effect. They improve their associative learning of odor and nectar reward by exhibiting increased memory acquisition, a component of long-term memory formation, when the time interval between rewarding trials is increased. Bombus impatiens forager memory acquisition (average discrimination index values) improved by 129% and 65% at inter-trial intervals (ITI) of 5 and 3 min, respectively, as compared to an ITI of 1 min. Memory acquisition rate also increased with increasing ITI. Encapsulation significantly increases olfactory memory acquisition. Ten times more foragers exhibited at least one PER response during training in capsules as compared to traditional PER harnesses. Thus, a novel conditioning assay, encapsulation, enabled us to improve bumblebee-learning acquisition and demonstrate that spaced learning results in better memory consolidation. Such spaced learning likely plays a role in forming long-term memories of rewarding floral resources.

  18. Applying the minimax principle to sequential mastery testing

    NARCIS (Netherlands)

    Vos, Hendrik J.

    2002-01-01

    The purpose of this paper is to derive optimal rules for sequential mastery tests. In a sequential mastery test, the decision is to classify a subject as a master, a nonmaster, or to continue sampling and administering another random item. The framework of minimax sequential decision theory (minimum

  19. Classical and sequential limit analysis revisited

    Science.gov (United States)

    Leblond, Jean-Baptiste; Kondo, Djimédo; Morin, Léo; Remmal, Almahdi

    2018-04-01

    Classical limit analysis applies to ideal plastic materials, and within a linearized geometrical framework implying small displacements and strains. Sequential limit analysis was proposed as a heuristic extension to materials exhibiting strain hardening, and within a fully general geometrical framework involving large displacements and strains. The purpose of this paper is to study and clearly state the precise conditions permitting such an extension. This is done by comparing the evolution equations of the full elastic-plastic problem, the equations of classical limit analysis, and those of sequential limit analysis. The main conclusion is that, whereas classical limit analysis applies to materials exhibiting elasticity - in the absence of hardening and within a linearized geometrical framework -, sequential limit analysis, to be applicable, strictly prohibits the presence of elasticity - although it tolerates strain hardening and large displacements and strains. For a given mechanical situation, the relevance of sequential limit analysis therefore essentially depends upon the importance of the elastic-plastic coupling in the specific case considered.

  20. On Modeling Large-Scale Multi-Agent Systems with Parallel, Sequential and Genuinely Asynchronous Cellular Automata

    International Nuclear Information System (INIS)

    Tosic, P.T.

    2011-01-01

    We study certain types of Cellular Automata (CA) viewed as an abstraction of large-scale Multi-Agent Systems (MAS). We argue that the classical CA model needs to be modified in several important respects, in order to become a relevant and sufficiently general model for the large-scale MAS, and so that thus generalized model can capture many important MAS properties at the level of agent ensembles and their long-term collective behavior patterns. We specifically focus on the issue of inter-agent communication in CA, and propose sequential cellular automata (SCA) as the first step, and genuinely Asynchronous Cellular Automata (ACA) as the ultimate deterministic CA-based abstract models for large-scale MAS made of simple reactive agents. We first formulate deterministic and nondeterministic versions of sequential CA, and then summarize some interesting configuration space properties (i.e., possible behaviors) of a restricted class of sequential CA. In particular, we compare and contrast those properties of sequential CA with the corresponding properties of the classical (that is, parallel and perfectly synchronous) CA with the same restricted class of update rules. We analytically demonstrate failure of the studied sequential CA models to simulate all possible behaviors of perfectly synchronous parallel CA, even for a very restricted class of non-linear totalistic node update rules. The lesson learned is that the interleaving semantics of concurrency, when applied to sequential CA, is not refined enough to adequately capture the perfect synchrony of parallel CA updates. Last but not least, we outline what would be an appropriate CA-like abstraction for large-scale distributed computing insofar as the inter-agent communication model is concerned, and in that context we propose genuinely asynchronous CA. (author)

  1. Simultaneous versus sequential penetrating keratoplasty and cataract surgery.

    Science.gov (United States)

    Hayashi, Ken; Hayashi, Hideyuki

    2006-10-01

    To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.

  2. Accelerated whole brain intracranial vessel wall imaging using black blood fast spin echo with compressed sensing (CS-SPACE).

    Science.gov (United States)

    Zhu, Chengcheng; Tian, Bing; Chen, Luguang; Eisenmenger, Laura; Raithel, Esther; Forman, Christoph; Ahn, Sinyeob; Laub, Gerhard; Liu, Qi; Lu, Jianping; Liu, Jing; Hess, Christopher; Saloner, David

    2018-06-01

    Develop and optimize an accelerated, high-resolution (0.5 mm isotropic) 3D black blood MRI technique to reduce scan time for whole-brain intracranial vessel wall imaging. A 3D accelerated T 1 -weighted fast-spin-echo prototype sequence using compressed sensing (CS-SPACE) was developed at 3T. Both the acquisition [echo train length (ETL), under-sampling factor] and reconstruction parameters (regularization parameter, number of iterations) were first optimized in 5 healthy volunteers. Ten patients with a variety of intracranial vascular disease presentations (aneurysm, atherosclerosis, dissection, vasculitis) were imaged with SPACE and optimized CS-SPACE, pre and post Gd contrast. Lumen/wall area, wall-to-lumen contrast ratio (CR), enhancement ratio (ER), sharpness, and qualitative scores (1-4) by two radiologists were recorded. The optimized CS-SPACE protocol has ETL 60, 20% k-space under-sampling, 0.002 regularization factor with 20 iterations. In patient studies, CS-SPACE and conventional SPACE had comparable image scores both pre- (3.35 ± 0.85 vs. 3.54 ± 0.65, p = 0.13) and post-contrast (3.72 ± 0.58 vs. 3.53 ± 0.57, p = 0.15), but the CS-SPACE acquisition was 37% faster (6:48 vs. 10:50). CS-SPACE agreed with SPACE for lumen/wall area, ER measurements and sharpness, but marginally reduced the CR. In the evaluation of intracranial vascular disease, CS-SPACE provides a substantial reduction in scan time compared to conventional T 1 -weighted SPACE while maintaining good image quality.

  3. Short-term memory for spatial, sequential and duration information.

    Science.gov (United States)

    Manohar, Sanjay G; Pertzov, Yoni; Husain, Masud

    2017-10-01

    Space and time appear to play key roles in the way that information is organized in short-term memory (STM). Some argue that they are crucial contexts within which other stored features are embedded, allowing binding of information that belongs together within STM. Here we review recent behavioral, neurophysiological and imaging studies that have sought to investigate the nature of spatial, sequential and duration representations in STM, and how these might break down in disease. Findings from these studies point to an important role of the hippocampus and other medial temporal lobe structures in aspects of STM, challenging conventional accounts of involvement of these regions in only long-term memory.

  4. Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols

    International Nuclear Information System (INIS)

    Neefjes, Lisan A.; Kate, Gert-Jan R. ten; Rossi, Alexia; Nieman, Koen; Papadopoulou, Stella L.; Dharampal, Anoeshka S.; Dedic, Admir; Feyter, Pim J. de; Mollet, Nico R.; Genders, Tessa S.S.; Hunink, M.G.M.; Schultz, Carl J.; Weustink, Annick C.; Dijkshoorn, Marcel L.; Straten, Marcel van; Cademartiri, Filippo; Krestin, Gabriel P.

    2013-01-01

    To compare the diagnostic performance and radiation exposure of 128-slice dual-source CT coronary angiography (CTCA) protocols to detect coronary stenosis with more than 50 % lumen obstruction. We prospectively included 459 symptomatic patients referred for CTCA. Patients were randomized between high-pitch spiral vs. narrow-window sequential CTCA protocols (heart rate below 65 bpm, group A), or between wide-window sequential vs. retrospective spiral protocols (heart rate above 65 bpm, group B). Diagnostic performance of CTCA was compared with quantitative coronary angiography in 267 patients. In group A (231 patients, 146 men, mean heart rate 58 ± 7 bpm), high-pitch spiral CTCA yielded a lower per-segment sensitivity compared to sequential CTCA (89 % vs. 97 %, P = 0.01). Specificity, PPV and NPV were comparable (95 %, 62 %, 99 % vs. 96 %, 73 %, 100 %, P > 0.05) but radiation dose was lower (1.16 ± 0.60 vs. 3.82 ± 1.65 mSv, P 0.05). Radiation dose of sequential CTCA was lower compared to retrospective CTCA (6.12 ± 2.58 vs. 8.13 ± 4.52 mSv, P < 0.001). Diagnostic performance was comparable in both groups. Sequential CTCA should be used in patients with regular heart rates using 128-slice dual-source CT, providing optimal diagnostic accuracy with as low as reasonably achievable (ALARA) radiation dose. circle 128-slice dual-source CT coronary angiography offers several different acquisition protocols. (orig.)

  5. Data acquisition system of the GDL facility

    International Nuclear Information System (INIS)

    Salikova, T.V.

    1992-01-01

    Data acquisition system (DAS) operates in the RSX-IIM environment with the CAMAC system CAMAC driven and CAMAC control processor are used for the CAMAC system operation support. The exchange rate between a problem and the CAMAC module is equal to 100 K worf/c. 14 refs

  6. Trial Sequential Methods for Meta-Analysis

    Science.gov (United States)

    Kulinskaya, Elena; Wood, John

    2014-01-01

    Statistical methods for sequential meta-analysis have applications also for the design of new trials. Existing methods are based on group sequential methods developed for single trials and start with the calculation of a required information size. This works satisfactorily within the framework of fixed effects meta-analysis, but conceptual…

  7. A distributed high speed data acquisition system for KT5C tokamak

    International Nuclear Information System (INIS)

    Sun Xiang; Wang Zhijiang; Lu Ronghua; Wang Jun; Yu Yi; Zhu Zhenghua; Wen Yizhi; Wan Shude; Liu Wandong; Yu Changxuan

    2005-01-01

    The development of a distributed data acquisition system with low cost to implement high speed data collection through the campus networks for a small tokamak, KT5C, is presented. Data of 512 k bytes at 5 MHz from 5 channels for each can be collected during about 10s after three researchers at different positions demand this system for acquisitions. This system realizes long distance multiuser operations; virtually efficiency of the data acquisition is enhanced. (authors)

  8. Sequentially pulsed traveling wave accelerator

    Science.gov (United States)

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA; Poole, Brian R [Tracy, CA

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  9. SU-F-J-220: Micro-CT Based Quantification of Mouse Brain Vasculature: The Effects of Acquisition Technique and Contrast Material

    International Nuclear Information System (INIS)

    Tipton, C; Lamba, M; Qi, Z; LaSance, K; Tipton, C

    2016-01-01

    Purpose: Cognitive impairment from radiation therapy to the brain may be linked to the loss of total blood volume in the brain. To account for brain injury, it is crucial to develop an understanding of blood volume loss as a result of radiation therapy. This study investigates µCT based quantification of mouse brain vasculature, focusing on the effect of acquisition technique and contrast material. Methods: Four mice were scanned on a µCT scanner (Siemens Inveon). The reconstructed voxel size was 18µm3 and all protocols were Hounsfield Unit (HU) calibrated. The mice were injected with 40mg of gold nanoparticles (MediLumine) or 100µl of Exitron 12000 (Miltenyi Biotec). Two acquisition techniques were also performed. A single kVp technique scanned the mouse once using an x-ray beam of 80kVp and segmentation was completed based on a threshold of HU values. The dual kVp technique scanned the mouse twice using 50kVp and 80kVp, this segmentation was based on the ratio of the HU value of the two kVps. After image reconstruction and segmentation, the brain blood volume was determined as a percentage of the total brain volume. Results: For the single kVp acquisition at 80kVp, the brain blood volume had an average of 3.5% for gold and 4.0% for Exitron 12000. Also at 80kVp, the contrast-noise ratio was significantly better for images acquired with the gold nanoparticles (2.0) than for those acquired with the Exitron 12000 (1.4). The dual kVp acquisition shows improved separation of skull from vasculature, but increased image noise. Conclusion: In summary, the effects of acquisition technique and contrast material for quantification of mouse brain vasculature showed that gold nanoparticles produced more consistent segmentation of brain vasculature than Exitron 12000. Also, dual kVp acquisition may improve the accuracy of brain vasculature quantification, although the effect of noise amplification warrants further study.

  10. SU-F-J-220: Micro-CT Based Quantification of Mouse Brain Vasculature: The Effects of Acquisition Technique and Contrast Material

    Energy Technology Data Exchange (ETDEWEB)

    Tipton, C; Lamba, M; Qi, Z; LaSance, K; Tipton, C [University of Cincinnati College of Medicine, Cincinnati, OH (United States)

    2016-06-15

    Purpose: Cognitive impairment from radiation therapy to the brain may be linked to the loss of total blood volume in the brain. To account for brain injury, it is crucial to develop an understanding of blood volume loss as a result of radiation therapy. This study investigates µCT based quantification of mouse brain vasculature, focusing on the effect of acquisition technique and contrast material. Methods: Four mice were scanned on a µCT scanner (Siemens Inveon). The reconstructed voxel size was 18µm3 and all protocols were Hounsfield Unit (HU) calibrated. The mice were injected with 40mg of gold nanoparticles (MediLumine) or 100µl of Exitron 12000 (Miltenyi Biotec). Two acquisition techniques were also performed. A single kVp technique scanned the mouse once using an x-ray beam of 80kVp and segmentation was completed based on a threshold of HU values. The dual kVp technique scanned the mouse twice using 50kVp and 80kVp, this segmentation was based on the ratio of the HU value of the two kVps. After image reconstruction and segmentation, the brain blood volume was determined as a percentage of the total brain volume. Results: For the single kVp acquisition at 80kVp, the brain blood volume had an average of 3.5% for gold and 4.0% for Exitron 12000. Also at 80kVp, the contrast-noise ratio was significantly better for images acquired with the gold nanoparticles (2.0) than for those acquired with the Exitron 12000 (1.4). The dual kVp acquisition shows improved separation of skull from vasculature, but increased image noise. Conclusion: In summary, the effects of acquisition technique and contrast material for quantification of mouse brain vasculature showed that gold nanoparticles produced more consistent segmentation of brain vasculature than Exitron 12000. Also, dual kVp acquisition may improve the accuracy of brain vasculature quantification, although the effect of noise amplification warrants further study.

  11. The Space Industry

    National Research Council Canada - National Science Library

    Borrelli, Carmine; Buckon, Danielle; Cogossi, Bruce; Davidson, Cynthia; Ditzler-Smith, Cristie; Doddato, August; Gabrielson, Charles; Hubbard, Kenneth; Jacocks, Kent; Jircitano, Valerie

    2007-01-01

    .... To ensure these, U.S. policy should encourage more commercial activity in space, emphasize a more globally cooperative environment, change acquisition methods to emphasize cost control over performance at any cost...

  12. Candidate sample acquisition systems for the Rosetta

    International Nuclear Information System (INIS)

    Magnani, P.G.; Gerli, C.; Colombina, G.; Vielmo, P.

    1989-01-01

    The Comet Nucleus Sample Return (CNSR) mission, one of the four cornerstones of the ESA scientific program, is one of the most complex space ventures within the next century, both from technological and deep space exploration point of view. In the Rosetta scenario the sample acquisition phase represents the most critical point for the global mission's success. The proposed paper illustrates the main results obtained in the context of the CNSR-SAS ongoing activity. The main areas covered are related to: (1) sample properties characterization (comet soil model, physical/chemical properties, reference material for testing); (2) concepts identification for coring, shovelling, harpooning and anchoring; (3) preferred concept (trade off among concepts, identification of the preferred configuration); and (4) proposed development activity for gaining the necessary confidence before finalizing the CNSR mission. Particular emphasis will be given to the robotic and flexibility aspects of the identified sample acquisition systems (SAS) configuration, intended as a means for the overall system performance enhancement

  13. An Efficient System Based On Closed Sequential Patterns for Web Recommendations

    OpenAIRE

    Utpala Niranjan; R.B.V. Subramanyam; V-Khana

    2010-01-01

    Sequential pattern mining, since its introduction has received considerable attention among the researchers with broad applications. The sequential pattern algorithms generally face problems when mining long sequential patterns or while using very low support threshold. One possible solution of such problems is by mining the closed sequential patterns, which is a condensed representation of sequential patterns. Recently, several researchers have utilized the sequential pattern discovery for d...

  14. Verbal Working Memory Is Related to the Acquisition of Cross-Linguistic Phonological Regularities.

    Science.gov (United States)

    Bosma, Evelyn; Heeringa, Wilbert; Hoekstra, Eric; Versloot, Arjen; Blom, Elma

    2017-01-01

    Closely related languages share cross-linguistic phonological regularities, such as Frisian -âld [ͻ:t] and Dutch -oud [ʱut], as in the cognate pairs kâld [kͻ:t] - koud [kʱut] 'cold' and wâld [wͻ:t] - woud [wʱut] 'forest'. Within Bybee's (1995, 2001, 2008, 2010) network model, these regularities are, just like grammatical rules within a language, generalizations that emerge from schemas of phonologically and semantically related words. Previous research has shown that verbal working memory is related to the acquisition of grammar, but not vocabulary. This suggests that verbal working memory supports the acquisition of linguistic regularities. In order to test this hypothesis we investigated whether verbal working memory is also related to the acquisition of cross-linguistic phonological regularities. For three consecutive years, 5- to 8-year-old Frisian-Dutch bilingual children ( n = 120) were tested annually on verbal working memory and a Frisian receptive vocabulary task that comprised four cognate categories: (1) identical cognates, (2) non-identical cognates that either do or (3) do not exhibit a phonological regularity between Frisian and Dutch, and (4) non-cognates. The results showed that verbal working memory had a significantly stronger effect on cognate category (2) than on the other three cognate categories. This suggests that verbal working memory is related to the acquisition of cross-linguistic phonological regularities. More generally, it confirms the hypothesis that verbal working memory plays a role in the acquisition of linguistic regularities.

  15. Comparison of two single-breath-held 3-D acquisitions with multi-breath-held 2-D cine steady-state free precession MRI acquisition in children with single ventricles

    Energy Technology Data Exchange (ETDEWEB)

    Atweh, Lamya A.; Dodd, Nicholas A.; Krishnamurthy, Ramkumar; Chu, Zili D. [Texas Children' s Hospital, EB Singleton Department of Pediatric Radiology, Cardiovascular Imaging, Houston, TX (United States); Pednekar, Amol [Philips Healthcare, Houston, TX (United States); Krishnamurthy, Rajesh [Texas Children' s Hospital, EB Singleton Department of Pediatric Radiology, Cardiovascular Imaging, Houston, TX (United States); Baylor College of Medicine, Department of Radiology, Houston, TX (United States); Baylor College of Medicine, Department of Pediatrics, Houston, TX (United States)

    2016-05-15

    Breath-held two-dimensional balanced steady-state free precession cine acquisition (2-D breath-held SSFP), accelerated with parallel imaging, is the method of choice for evaluating ventricular function due to its superior blood-to-myocardial contrast, edge definition and high intrinsic signal-to-noise ratio throughout the cardiac cycle. The purpose of this study is to qualitatively and quantitatively compare the two different single-breath-hold 3-D cine SSFP acquisitions using 1) multidirectional sensitivity encoding (SENSE) acceleration factors (3-D multiple SENSE SSFP), and 2) k-t broad-use linear acceleration speed-up technique (3-D k-t SSFP) with the conventional 2-D breath-held SSFP in non-sedated asymptomatic volunteers and children with single ventricle congenital heart disease. Our prospective study was performed on 30 non-sedated subjects (9 healthy volunteers and 21 functional single ventricle patients), ages 12.5 +/- 2.8 years. Two-dimensional breath-held SSFP with SENSE acceleration factor of 2, eight-fold accelerated 3-D k-t SSFP, and 3-D multiple SENSE SSFP with total parallel imaging factor of 4 were performed to evaluate ventricular volumes and mass in the short-axis orientation. Image quality scores (blood myocardial contrast, edge definition and interslice alignment) and volumetric analysis (end systolic volume, end diastolic volume and ejection fraction) were performed on the data sets by experienced users. Paired t-test was performed to compare each of the 3-D k-t SSFP and 3-D multiple SENSE SSFP clinical scores against 2-D breath-held SSFP. Bland-Altman analysis was performed on left ventricle (LV) and single ventricle volumetry. Interobserver and intraobserver variability in volumetric measurements were determined using intraclass coefficients. The clinical scores were highest for the 2-D breath-held SSFP images. Between the two 3-D sequences, 3-D multiple SENSE SSFP performed better than 3-D k-t SSFP. Bland-Altman analysis for volumes

  16. Sequential decisions: a computational comparison of observational and reinforcement accounts.

    Directory of Open Access Journals (Sweden)

    Nazanin Mohammadi Sepahvand

    Full Text Available Right brain damaged patients show impairments in sequential decision making tasks for which healthy people do not show any difficulty. We hypothesized that this difficulty could be due to the failure of right brain damage patients to develop well-matched models of the world. Our motivation is the idea that to navigate uncertainty, humans use models of the world to direct the decisions they make when interacting with their environment. The better the model is, the better their decisions are. To explore the model building and updating process in humans and the basis for impairment after brain injury, we used a computational model of non-stationary sequence learning. RELPH (Reinforcement and Entropy Learned Pruned Hypothesis space was able to qualitatively and quantitatively reproduce the results of left and right brain damaged patient groups and healthy controls playing a sequential version of Rock, Paper, Scissors. Our results suggests that, in general, humans employ a sub-optimal reinforcement based learning method rather than an objectively better statistical learning approach, and that differences between right brain damaged and healthy control groups can be explained by different exploration policies, rather than qualitatively different learning mechanisms.

  17. Phonology-morphology interaction: Acquisition of Danish noun plurals as a test case

    DEFF Research Database (Denmark)

    Kjærbæk, Laila; Basbøll, Hans

    2010-01-01

    Acquisition in Normal and Hearing Impaired Populations". In E. Schmidt, U. Mikkelsen, I. Post, J. B. Simonsen & K. Fruensgaard (eds.), Brain, Hearing and Learning. 20th Danavox Symposium 2003: 165-190. Bleses, D., Vach, W., Wehberg, S., Kristensen, K. F. & Madsen, T. O. (2007). Tidlig kommunikativ udvikling...... Development Inventories: Validity and Main Developmental Trends". Journal of Child Language 35, 651-69. Bleses, D., Vach, W., Slott, M., Wehberg, S., Thomsen, P., Madsen, T. & Basbøll, H. (2008b). “Early Vocabulary Development in Danish and Other Languages: a CDI-based Comparison”. Journal of Child Language...... on the Occasion of his 60th Birthday 12 July 2003. Odense: Syddansk Universitetsforlag. Slobin, D. I. (ed.) (1985a). The Crosslinguistic Study of Language Acquisition. Hillsdale, NJ: Lawrence Earlbaum Associates. Slobin, D. I. (ed.) (1985b). The Crosslinguistic Study of Language Acquisition. Hillsdale, NJ...

  18. Laplacian eigenmodes for spherical spaces

    International Nuclear Information System (INIS)

    Lachieze-Rey, M; Caillerie, S

    2005-01-01

    The possibility that our space is multi-rather than singly-connected has gained renewed interest after the discovery of the low power for the first multipoles of the CMB by WMAP. To test the possibility that our space is a multi-connected spherical space, it is necessary to know the eigenmodes of such spaces. Except for lens and prism space, and to some extent for dodecahedral space, this remains an open problem. Here we derive the eigenmodes of all spherical spaces. For dodecahedral space, the demonstration is much shorter, and the calculation method much simpler than before. We also apply our method to tetrahedric, octahedric and icosahedric spaces. This completes the knowledge of eigenmodes for spherical spaces, and opens the door to new observational tests of the cosmic topology. The vector space V k of the eigenfunctions of the Laplacian on the 3-sphere S 3 , corresponding to the same eigenvalue λ k = -k(k + 2), has dimension (k + 1) 2 . We show that the Wigner functions provide a basis for such a space. Using the properties of the latter, we express the behaviour of a general function of V k under an arbitrary rotation G of SO(4). This offers the possibility of selecting those functions of V k which remain invariant under G. Specifying G to be a generator of the holonomy group of a spherical space X, we give the expression of the vector space V x k of the eigenfunctions of X. We provide a method to calculate the eigenmodes up to an arbitrary order. As an illustration, we give the first modes for the spherical spaces mentioned

  19. SCI based data acquisition architectures

    International Nuclear Information System (INIS)

    Bogaerts, J.A.C.; Divia, R.; Renardy, J.F.

    1992-01-01

    This paper discusses the Scalable Coherent Interface (SCI), an IEEE proposed standard (P1596) for interconnecting multiprocessor systems. The standard defines point to point connections between nodes, which can be processors, memories or I/O devices. Networks containing a maximum of 64K nodes with a bandwidth of one Gbyte/s between nodes, may be constructed. SCI is an attractive candidate to serve as a backbone for high speed, large volume data acquisition systems such as required by future experiments at the proposed Large Hadron Collider (LHC) at CERN. Work has started to simulate SCI based architectures for data acquisition systems. The simulation program proved to be a useful tool to study SCI systems. First results are reported on a model of a large LHC experiment containing over 1000 nodes

  20. Down two steps: Are bilinguals delayed in the acquisition of recursively embedded PPs?

    Directory of Open Access Journals (Sweden)

    Ana Pérez-Leroux

    2017-08-01

    Full Text Available The present study examines whether bilingual children are delayed in the ability to produce complex DPs. We elicited production of DPs containing two PP modifiers, in two conditions designed to tease apart the acquisition of an embedding rule from the acquisition of the recursivity of an embedding rule. In the recursive condition, one modifier PP was itself modified by an additional PP. In the non-recursive condition, both PPs sequentially modified the main noun. Participants were 71 English monolingual children and 35 bilinguals between the ages of four and six. The evidence suggested an overall difference between groups, however further analysis revealed that bilinguals differed from monolinguals only insofar as the onset of PP embedding. No specific additional bilingual delay arose from the recursive condition. This suggests that recursive embedding is a resilient domain in language acquisition and supports proposals that link morphosyntactic delays in bilingual children to domains of grammar that are heavily reliant on lexical learning, which would include learning the first instance of PP embedding. --- Original in English.   --- DOI: http://dx.doi.org/10.12957/matraga.2017.28781

  1. Project for the Space Science in Moscow State University of Geodesy and Cartography (MIIGAiK)

    Science.gov (United States)

    Semenov, M.; Oberst, J.; Malinnikov, V.; Shingareva, K.; Grechishchev, A.; Karachevtseva, I.; Konopikhin, A.

    2012-04-01

    Introduction: Based on the proposal call of the Government of Russian Federation 40 of international scientists came to Russia for developing and support-ing research capabilities of national educational institutions. Moscow State University of Geodesy and Cartography (MIIGAiK) and invited scientist Prof. Dr. Jurgen Oberst were awarded a grant to establish a capable research facility concerned with Planetary Geodesy, Cartography and Space Exploration. Objectives: The goals of the project are to build laboratory infrastructure, and suitable capability for MIIGAiK to participate in the planning, execution and analyses of data from future Russian planetary mis-sions and also to integrate into the international science community. Other important tasks are to develop an attractive work place and job opportunities for planetary geodesy and cartography students. For this purposes new MIIGAiK Extraterrestrial Laboratory (MExLab) was organized. We involved professors, researchers, PhD students in to the projects of Moon and planets exploration at the new level of Russian Space Science development. Main results: MExLab team prepare data for upcom-ing Russian space missions, such as LUNA-GLOB and LUNA-RESOURSE. We established cooperation with Russian and international partners (IKI, ESA, DLR, and foreign Universities) and actively participated in international conferences and workshops. Future works: For the future science development we investigated the old Soviet Archives and received the access to the telemetry data of the Moon rovers Lunokhod-1 and Lunokhod-2. That data will be used in education purposes and could be the perfect base for the analysis, development and support in new Russian and international missions and especially Moon exploration projects. MExLab is open to cooperate and make the consortiums for science projects for the Moon and planets exploration. Acknowledgement: Works are funded by the Rus-sian Government (Project name: "Geodesy, cartography and the

  2. Free topological vector spaces

    OpenAIRE

    Gabriyelyan, Saak S.; Morris, Sidney A.

    2016-01-01

    We define and study the free topological vector space $\\mathbb{V}(X)$ over a Tychonoff space $X$. We prove that $\\mathbb{V}(X)$ is a $k_\\omega$-space if and only if $X$ is a $k_\\omega$-space. If $X$ is infinite, then $\\mathbb{V}(X)$ contains a closed vector subspace which is topologically isomorphic to $\\mathbb{V}(\\mathbb{N})$. It is proved that if $X$ is a $k$-space, then $\\mathbb{V}(X)$ is locally convex if and only if $X$ is discrete and countable. If $X$ is a metrizable space it is shown ...

  3. Sample Acquisition for Materials in Planetary Exploration (SAMPLE), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — ORBITEC proposes to analyze, design, and develop a device for autonomous lunar surface/subsurface sampling and processing applications. The Sample Acquisition for...

  4. Minimal computational-space implementation of multiround quantum protocols

    International Nuclear Information System (INIS)

    Bisio, Alessandro; D'Ariano, Giacomo Mauro; Perinotti, Paolo; Chiribella, Giulio

    2011-01-01

    A single-party strategy in a multiround quantum protocol can be implemented by sequential networks of quantum operations connected by internal memories. Here, we provide an efficient realization in terms of computational-space resources.

  5. 48 CFR 1852.225-8 - Duty-free entry of space articles.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Duty-free entry of space articles. 1852.225-8 Section 1852.225-8 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND SPACE ADMINISTRATION CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES Texts of Provisions...

  6. Fourth generation CP violation effects on B-->Kpi, phiK, and rhoK in next-to-leading-order perturbative QCD.

    Science.gov (United States)

    Hou, Wei-Shu; Li, Hsiang-nan; Mishima, Satoshi; Nagashima, Makiko

    2007-03-30

    We study the effect from a sequential fourth generation quark on penguin-dominated two-body nonleptonic B meson decays in the next-to-leading order perturbative QCD formalism. With an enhancement of the color-suppressed tree amplitude and possibility of a new CP phase in the electroweak penguin amplitude, we can account better for A(CP)(B(0)-->K+ pi-)-A(CP)(B+-->K+ pi0). Taking |V(t's)V(t'b)| approximately 0.02 with a phase just below 90 degrees, which is consistent with the b-->sl+ l- rate and the B(s) mixing parameter Deltam(B)(s), we find a downward shift in the mixing-induced CP asymmetries of B(0)-->K(S)(pi 0) and phi(K)(S). The predicted behavior for B(0)-->rho(0)(K)(S) is opposite.

  7. Performance of the NOνA Data Acquisition and Trigger Systems for the full 14 kT Far Detector

    International Nuclear Information System (INIS)

    Norman, A.; Ding, P.F.; Rebel, B.; Shanahan, P.; Davies, G.S.; Niner, E.; Dukes, E.C.; Frank, M.J.; Group, R.C.; Henderson, W.; Mina, R.; Oksuzian, Y.; Duyan, H.; Habig, A.; Moren, A.; Tomsen, K.; Mualem, L.; Sheshukov, A.; Tamsett, M.; Vinton, L.

    2015-01-01

    The NOvA experiment uses a continuous, free-running, dead-timeless data acquisition system to collect data from the 14 kT far detector. The DAQ system readouts the more than 344,000 detector channels and assembles the information into an raw unfiltered high bandwidth data stream. The NOvA trigger systems operate in parallel to the readout and asynchronously to the primary DAQ readout/event building chain. The data driven triggering systems for NOvA are unique in that they examine long contiguous time windows of the high resolution readout data and enable the detector to be sensitive to a wide range of physics interactions from those with fast, nanosecond scale signals up to processes with long delayed coincidences between hits which occur at the tens of milliseconds time scale. The trigger system is able to achieve a true 100% live time for the detector, making it sensitive to both beam spill related and off-spill physics. (paper)

  8. 30 CFR 879.11 - Land eligible for acquisition.

    Science.gov (United States)

    2010-07-01

    ... INTERIOR ABANDONED MINE LAND RECLAMATION ACQUISITION, MANAGEMENT, AND DISPOSITION OF LANDS AND WATER § 879... provide open space benefits after restoration, reclamation, abatement, control, or prevention of the... land for the restoration, reclamation, abatement, control, or prevention of the adverse effects of past...

  9. Software for FASTBUS and Motorola 68K based readout controllers for data acquisition

    International Nuclear Information System (INIS)

    Pordes, R.; Bernett, M.; Dorries, T.; Haire, M.; Moore, C.; Oleynik, G.; Votava, M.

    1989-01-01

    Many High Energy Physics experiments at Fermilab are now including FASTBUS front-ends in their data acquisition systems. The requirements on controllers to readout and control these FASTBUS systems are increasing in complexity and speed. The Data Acquisition Software Group has designed general software for front end 68Κ processor boards housed in FASTBUS or VME to meet these needs. The first implementation has been developed for the General Purpose FASTBUS Master (GPM). This software is being ported to the FASTBUS Smart Crate Controller under development at Fermilab. The software is designed, using structured analysis tools and coding in C, to be easily portable in the future to new processor boards. As part of their extended support for FASTBUS, they have enhanced their software for the intelligent LeCroy 1821 FASTBUS interface and implemented the FASTBUS standard routines for the VAX/VMS operating system

  10. Discrimination between sequential and simultaneous virtual channels with electrical hearing.

    Science.gov (United States)

    Landsberger, David; Galvin, John J

    2011-09-01

    In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation modes. For sequential VCs, the interpulse interval (IPI) varied between 0.0 and 1.8 ms. All stimuli were presented at comfortably loud, loudness-balanced levels at a 250 pulse per second per electrode (ppse) stimulation rate. On average, CI subjects were able to reliably discriminate between sequential and simultaneous VCs. While there was no significant effect of IPI or stimulation mode on VC discrimination, some subjects exhibited better VC discrimination with BP + 1 stimulation. Subjects' discrimination between sequential and simultaneous VCs was correlated with electrode discrimination, suggesting that spatial selectivity may influence perception of sequential VCs. To maintain equal loudness, sequential VC amplitudes were nearly double those of simultaneous VCs, presumably resulting in a broader spread of excitation. These results suggest that perceptual differences between simultaneous and sequential VCs might be explained by differences in the spread of excitation. © 2011 Acoustical Society of America

  11. Characterization of phosphorus species in sediments from the Arabian Sea oxygen minimum zone: Combining sequential extractions and X-ray spectroscopy

    NARCIS (Netherlands)

    Kraal, Peter; Bostick, Benjamin C.; Behrends, Thilo; Reichart, Gert-Jan; Slomp, Caroline P.

    2015-01-01

    The bulk phosphorus (P) distribution in sediment samples from the oxygen minimum zone of the northern Arabian Sea was determined using two methods: sequential chemical extraction (the ‘SEDEX’ procedure) and X-ray absorption near-edge structure (XANES) spectroscopy of the phosphorus K-edge. Our

  12. Sequential motion of the ossicular chain measured by laser Doppler vibrometry.

    Science.gov (United States)

    Kunimoto, Yasuomi; Hasegawa, Kensaku; Arii, Shiro; Kataoka, Hideyuki; Yazama, Hiroaki; Kuya, Junko; Fujiwara, Kazunori; Takeuchi, Hiromi

    2017-12-01

    In order to help a surgeon make the best decision, a more objective method of measuring ossicular motion is required. A laser Doppler vibrometer was mounted on a surgical microscope. To measure ossicular chain vibrations, eight patients with cochlear implants were investigated. To assess the motions of the ossicular chain, velocities at five points were measured with tonal stimuli of 1 and 3 kHz, which yielded reproducible results. The sequential amplitude change at each point was calculated with phase shifting from the tonal stimulus. Motion of the ossicular chain was visualized from the averaged results using the graphics application. The head of the malleus and the body of the incus showed synchronized movement as one unit. In contrast, the stapes (incudostapedial joint and posterior crus) moved synchronously in opposite phase to the malleus and incus. The amplitudes at 1 kHz were almost twice those at 3 kHz. Our results show that the malleus and incus unit and the stapes move with a phase difference.

  13. Facilitated assignment of large protein NMR signals with covariance sequential spectra using spectral derivatives.

    Science.gov (United States)

    Harden, Bradley J; Nichols, Scott R; Frueh, Dominique P

    2014-09-24

    Nuclear magnetic resonance (NMR) studies of larger proteins are hampered by difficulties in assigning NMR resonances. Human intervention is typically required to identify NMR signals in 3D spectra, and subsequent procedures depend on the accuracy of this so-called peak picking. We present a method that provides sequential connectivities through correlation maps constructed with covariance NMR, bypassing the need for preliminary peak picking. We introduce two novel techniques to minimize false correlations and merge the information from all original 3D spectra. First, we take spectral derivatives prior to performing covariance to emphasize coincident peak maxima. Second, we multiply covariance maps calculated with different 3D spectra to destroy erroneous sequential correlations. The maps are easy to use and can readily be generated from conventional triple-resonance experiments. Advantages of the method are demonstrated on a 37 kDa nonribosomal peptide synthetase domain subject to spectral overlap.

  14. 48 CFR 552.270-29 - Acceptance of Space.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Acceptance of Space. 552... Acceptance of Space. As prescribed in 570.603, insert the following clause: Acceptance of Space (SEP 1999) (a... designated representative shall promptly inspect the space. (b) The Government will accept the space and the...

  15. Glial K(+) Clearance and Cell Swelling

    DEFF Research Database (Denmark)

    Macaulay, Nanna; Zeuthen, Thomas

    2012-01-01

    An important feature of neuronal signalling is the increased concentration of K(+) in the extracellular space. The K(+) concentration is restored to its original basal level primarily by uptake into nearby glial cells. The molecular mechanisms by which K(+) is transferred from the extracellular...... space into the glial cell are debated. Although spatial buffer currents may occur, their quantitative contribution to K(+) clearance is uncertain. The concept of spatial buffering of K(+) precludes intracellular K(+) accumulation and is therefore (i) difficult to reconcile with the K(+) accumulation...

  16. Visual Working Memory Is Independent of the Cortical Spacing Between Memoranda.

    Science.gov (United States)

    Harrison, William J; Bays, Paul M

    2018-03-21

    The sensory recruitment hypothesis states that visual short-term memory is maintained in the same visual cortical areas that initially encode a stimulus' features. Although it is well established that the distance between features in visual cortex determines their visibility, a limitation known as crowding, it is unknown whether short-term memory is similarly constrained by the cortical spacing of memory items. Here, we investigated whether the cortical spacing between sequentially presented memoranda affects the fidelity of memory in humans (of both sexes). In a first experiment, we varied cortical spacing by taking advantage of the log-scaling of visual cortex with eccentricity, presenting memoranda in peripheral vision sequentially along either the radial or tangential visual axis with respect to the fovea. In a second experiment, we presented memoranda sequentially either within or beyond the critical spacing of visual crowding, a distance within which visual features cannot be perceptually distinguished due to their nearby cortical representations. In both experiments and across multiple measures, we found strong evidence that the ability to maintain visual features in memory is unaffected by cortical spacing. These results indicate that the neural architecture underpinning working memory has properties inconsistent with the known behavior of sensory neurons in visual cortex. Instead, the dissociation between perceptual and memory representations supports a role of higher cortical areas such as posterior parietal or prefrontal regions or may involve an as yet unspecified mechanism in visual cortex in which stimulus features are bound to their temporal order. SIGNIFICANCE STATEMENT Although much is known about the resolution with which we can remember visual objects, the cortical representation of items held in short-term memory remains contentious. A popular hypothesis suggests that memory of visual features is maintained via the recruitment of the same neural

  17. Rapid anatomical brain imaging using spiral acquisition and an expanded signal model.

    Science.gov (United States)

    Kasper, Lars; Engel, Maria; Barmet, Christoph; Haeberlin, Maximilian; Wilm, Bertram J; Dietrich, Benjamin E; Schmid, Thomas; Gross, Simon; Brunner, David O; Stephan, Klaas E; Pruessmann, Klaas P

    2018-03-01

    We report the deployment of spiral acquisition for high-resolution structural imaging at 7T. Long spiral readouts are rendered manageable by an expanded signal model including static off-resonance and B 0 dynamics along with k-space trajectories and coil sensitivity maps. Image reconstruction is accomplished by inversion of the signal model using an extension of the iterative non-Cartesian SENSE algorithm. Spiral readouts up to 25 ms are shown to permit whole-brain 2D imaging at 0.5 mm in-plane resolution in less than a minute. A range of options is explored, including proton-density and T 2 * contrast, acceleration by parallel imaging, different readout orientations, and the extraction of phase images. Results are shown to exhibit competitive image quality along with high geometric consistency. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Acquisition of gamma camera and physiological data by computer

    International Nuclear Information System (INIS)

    Hack, S.N.; Chang, M.; Line, B.R.; Cooper, J.A.; Robeson, G.H.

    1986-01-01

    We have designed, implemented, and tested a new Research Data Acquisition System (RDAS) that permits a general purpose digital computer to acquire signals from both gamma camera sources and physiological signal sources concurrently. This system overcomes the limited multi-source, high speed data acquisition capabilities found in most clinically oriented nuclear medicine computers. The RDAS can simultaneously input signals from up to four gamma camera sources with a throughput of 200 kHz per source and from up to eight physiological signal sources with an aggregate throughput of 50 kHz. Rigorous testing has found the RDAS to exhibit acceptable linearity and timing characteristics. In addition, flood images obtained by this system were compared with flood images acquired by a commercial nuclear medicine computer system. National Electrical Manufacturers Association performance standards of the flood images were found to be comparable

  19. New protocol for dissociating visuospatial working memory ability in reaching space and in navigational space.

    Science.gov (United States)

    Lupo, Michela; Ferlazzo, Fabio; Aloise, Fabio; Di Nocera, Francesco; Tedesco, Anna Maria; Cardillo, Chiara; Leggio, Maria

    2018-04-27

    Several studies have demonstrated that the processing of visuospatial memory for locations in reaching space and in navigational space is supported by independent systems, and that the coding of visuospatial information depends on the modality of the presentation (i.e., sequential or simultaneous). However, these lines of evidence and the most common neuropsychological tests used by clinicians to investigate visuospatial memory have several limitations (e.g., they are unable to analyze all the subcomponents of this function and are not directly comparable). Therefore, we developed a new battery of tests that is able to investigate these subcomponents. We recruited 71 healthy subjects who underwent sequential and simultaneous navigational tests by using an innovative sensorized platform, as well as comparable paper tests to evaluate the same components in reaching space (Exp. 1). Consistent with the literature, the principal-component method of analysis used in this study demonstrated the presence of distinct memory for sequences in different portions of space, but no distinction was found for simultaneous presentation, suggesting that different modalities of eye gaze exploration are used when subjects have to perform different types of tasks. For this purpose, an infrared Tobii Eye-Tracking X50 system was used in both spatial conditions (Exp. 2), showing that a clear effect of the presentation modality was due to the specific strategy used by subjects to explore the stimuli in space. Given these findings, the neuropsychological battery established in the present study allows us to show basic differences in the normal coding of stimuli, which can explain the specific visuospatial deficits found in various neurological conditions.

  20. Collection of sequential imaging events for research in breast cancer screening

    Science.gov (United States)

    Patel, M. N.; Young, K.; Halling-Brown, M. D.

    2016-03-01

    Due to the huge amount of research involving medical images, there is a widely accepted need for comprehensive collections of medical images to be made available for research. This demand led to the design and implementation of a flexible image repository, which retrospectively collects images and data from multiple sites throughout the UK. The OPTIMAM Medical Image Database (OMI-DB) was created to provide a centralized, fully annotated dataset for research. The database contains both processed and unprocessed images, associated data, annotations and expert-determined ground truths. Collection has been ongoing for over three years, providing the opportunity to collect sequential imaging events. Extensive alterations to the identification, collection, processing and storage arms of the system have been undertaken to support the introduction of sequential events, including interval cancers. These updates to the collection systems allow the acquisition of many more images, but more importantly, allow one to build on the existing high-dimensional data stored in the OMI-DB. A research dataset of this scale, which includes original normal and subsequent malignant cases along with expert derived and clinical annotations, is currently unique. These data provide a powerful resource for future research and has initiated new research projects, amongst which, is the quantification of normal cases by applying a large number of quantitative imaging features, with a priori knowledge that eventually these cases develop a malignancy. This paper describes, extensions to the OMI-DB collection systems and tools and discusses the prospective applications of having such a rich dataset for future research applications.

  1. Mammographic x-ray unit kilovoltage test tool based on k-edge absorption effect.

    Science.gov (United States)

    Napolitano, Mary E; Trueblood, Jon H; Hertel, Nolan E; David, George

    2002-09-01

    A simple tool to determine the peak kilovoltage (kVp) of a mammographic x-ray unit has been designed. Tool design is based on comparing the effect of k-edge discontinuity of the attenuation coefficient for a series of element filters. Compatibility with the mammography accreditation phantom (MAP) to obtain a single quality control film is a second design objective. When the attenuation of a series of sequential elements is studied simultaneously, differences in the absorption characteristics due to the k-edge discontinuities are more evident. Specifically, when the incident photon energy is higher than the k-edge energy of a number of the elements and lower than the remainder, an inflection may be seen in the resulting attenuation data. The maximum energy of the incident photon spectra may be determined based on this inflection point for a series of element filters. Monte Carlo photon transport analysis was used to estimate the photon transmission probabilities for each of the sequential k-edge filter elements. The photon transmission corresponds directly to optical density recorded on mammographic x-ray film. To observe the inflection, the element filters chosen must have k-edge energies that span a range greater than the expected range of the end point energies to be determined. For the design, incident x-ray spectra ranging from 25 to 40 kVp were assumed to be from a molybdenum target. Over this range, the k-edge energy changes by approximately 1.5 keV between sequential elements. For this design 21 elements spanning an energy range from 20 to 50 keV were chosen. Optimum filter element thicknesses were calculated to maximize attenuation differences at the k-edge while maintaining optical densities between 0.10 and 3.00. Calculated relative transmission data show that the kVp could be determined to within +/-1 kV. To obtain experimental data, a phantom was constructed containing 21 different elements placed in an acrylic holder. MAP images were used to determine

  2. Mammographic x-ray unit kilovoltage test tool based on k-edge absorption effect

    International Nuclear Information System (INIS)

    Napolitano, Mary E.; Trueblood, Jon H.; Hertel, Nolan E.; David, George

    2002-01-01

    A simple tool to determine the peak kilovoltage (kVp) of a mammographic x-ray unit has been designed. Tool design is based on comparing the effect of k-edge discontinuity of the attenuation coefficient for a series of element filters. Compatibility with the mammography accreditation phantom (MAP) to obtain a single quality control film is a second design objective. When the attenuation of a series of sequential elements is studied simultaneously, differences in the absorption characteristics due to the k-edge discontinuities are more evident. Specifically, when the incident photon energy is higher than the k-edge energy of a number of the elements and lower than the remainder, an inflection may be seen in the resulting attenuation data. The maximum energy of the incident photon spectra may be determined based on this inflection point for a series of element filters. Monte Carlo photon transport analysis was used to estimate the photon transmission probabilities for each of the sequential k-edge filter elements. The photon transmission corresponds directly to optical density recorded on mammographic x-ray film. To observe the inflection, the element filters chosen must have k-edge energies that span a range greater than the expected range of the end point energies to be determined. For the design, incident x-ray spectra ranging from 25 to 40 kVp were assumed to be from a molybdenum target. Over this range, the k-edge energy changes by approximately 1.5 keV between sequential elements. For this design 21 elements spanning an energy range from 20 to 50 keV were chosen. Optimum filter element thicknesses were calculated to maximize attenuation differences at the k-edge while maintaining optical densities between 0.10 and 3.00. Calculated relative transmission data show that the kVp could be determined to within ±1 kV. To obtain experimental data, a phantom was constructed containing 21 different elements placed in an acrylic holder. MAP images were used to determine

  3. Verbal Working Memory Is Related to the Acquisition of Cross-Linguistic Phonological Regularities

    Directory of Open Access Journals (Sweden)

    Evelyn Bosma

    2017-09-01

    Full Text Available Closely related languages share cross-linguistic phonological regularities, such as Frisian -âld [ͻ:t] and Dutch -oud [ʱut], as in the cognate pairs kâld [kͻ:t] – koud [kʱut] ‘cold’ and wâld [wͻ:t] – woud [wʱut] ‘forest’. Within Bybee’s (1995, 2001, 2008, 2010 network model, these regularities are, just like grammatical rules within a language, generalizations that emerge from schemas of phonologically and semantically related words. Previous research has shown that verbal working memory is related to the acquisition of grammar, but not vocabulary. This suggests that verbal working memory supports the acquisition of linguistic regularities. In order to test this hypothesis we investigated whether verbal working memory is also related to the acquisition of cross-linguistic phonological regularities. For three consecutive years, 5- to 8-year-old Frisian-Dutch bilingual children (n = 120 were tested annually on verbal working memory and a Frisian receptive vocabulary task that comprised four cognate categories: (1 identical cognates, (2 non-identical cognates that either do or (3 do not exhibit a phonological regularity between Frisian and Dutch, and (4 non-cognates. The results showed that verbal working memory had a significantly stronger effect on cognate category (2 than on the other three cognate categories. This suggests that verbal working memory is related to the acquisition of cross-linguistic phonological regularities. More generally, it confirms the hypothesis that verbal working memory plays a role in the acquisition of linguistic regularities.

  4. Sequential sampling of visual objects during sustained attention.

    Directory of Open Access Journals (Sweden)

    Jianrong Jia

    2017-06-01

    Full Text Available In a crowded visual scene, attention must be distributed efficiently and flexibly over time and space to accommodate different contexts. It is well established that selective attention enhances the corresponding neural responses, presumably implying that attention would persistently dwell on the task-relevant item. Meanwhile, recent studies, mostly in divided attentional contexts, suggest that attention does not remain stationary but samples objects alternately over time, suggesting a rhythmic view of attention. However, it remains unknown whether the dynamic mechanism essentially mediates attentional processes at a general level. Importantly, there is also a complete lack of direct neural evidence reflecting whether and how the brain rhythmically samples multiple visual objects during stimulus processing. To address these issues, in this study, we employed electroencephalography (EEG and a temporal response function (TRF approach, which can dissociate responses that exclusively represent a single object from the overall neuronal activity, to examine the spatiotemporal characteristics of attention in various attentional contexts. First, attention, which is characterized by inhibitory alpha-band (approximately 10 Hz activity in TRFs, switches between attended and unattended objects every approximately 200 ms, suggesting a sequential sampling even when attention is required to mostly stay on the attended object. Second, the attentional spatiotemporal pattern is modulated by the task context, such that alpha-mediated switching becomes increasingly prominent as the task requires a more uniform distribution of attention. Finally, the switching pattern correlates with attentional behavioral performance. Our work provides direct neural evidence supporting a generally central role of temporal organization mechanism in attention, such that multiple objects are sequentially sorted according to their priority in attentional contexts. The results suggest

  5. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...

  6. Sequential logic analysis and synthesis

    CERN Document Server

    Cavanagh, Joseph

    2007-01-01

    Until now, there was no single resource for actual digital system design. Using both basic and advanced concepts, Sequential Logic: Analysis and Synthesis offers a thorough exposition of the analysis and synthesis of both synchronous and asynchronous sequential machines. With 25 years of experience in designing computing equipment, the author stresses the practical design of state machines. He clearly delineates each step of the structured and rigorous design principles that can be applied to practical applications. The book begins by reviewing the analysis of combinatorial logic and Boolean a

  7. Extremelly High Bandwidth Rad Hard Data Acquisition System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Analog-to-digital converters (ADCs) are the key components for digitizing high-speed analog data in modern data acquisition systems, which is a critical part of...

  8. Articulated Human Motion Tracking Using Sequential Immune Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Yi Li

    2013-01-01

    Full Text Available We formulate human motion tracking as a high-dimensional constrained optimization problem. A novel generative method is proposed for human motion tracking in the framework of evolutionary computation. The main contribution is that we introduce immune genetic algorithm (IGA for pose optimization in latent space of human motion. Firstly, we perform human motion analysis in the learnt latent space of human motion. As the latent space is low dimensional and contents the prior knowledge of human motion, it makes pose analysis more efficient and accurate. Then, in the search strategy, we apply IGA for pose optimization. Compared with genetic algorithm and other evolutionary methods, its main advantage is the ability to use the prior knowledge of human motion. We design an IGA-based method to estimate human pose from static images for initialization of motion tracking. And we propose a sequential IGA (S-IGA algorithm for motion tracking by incorporating the temporal continuity information into the traditional IGA. Experimental results on different videos of different motion types show that our IGA-based pose estimation method can be used for initialization of motion tracking. The S-IGA-based motion tracking method can achieve accurate and stable tracking of 3D human motion.

  9. Structural Consistency, Consistency, and Sequential Rationality.

    OpenAIRE

    Kreps, David M; Ramey, Garey

    1987-01-01

    Sequential equilibria comprise consistent beliefs and a sequentially ra tional strategy profile. Consistent beliefs are limits of Bayes ratio nal beliefs for sequences of strategies that approach the equilibrium strategy. Beliefs are structurally consistent if they are rationaliz ed by some single conjecture concerning opponents' strategies. Consis tent beliefs are not necessarily structurally consistent, notwithstan ding a claim by Kreps and Robert Wilson (1982). Moreover, the spirit of stru...

  10. Sequential acquisition of R-plasmids in vivo by Salmonella typhimurium.

    Science.gov (United States)

    Platt, D J; Sommerville, J S; Gribben, J

    1984-01-01

    Salmonella typhimurium, resistant only to trimethoprim and sulphamethoxazole, was isolated from the faeces and blood of a chronic alcoholic patient in acute renal failure. The isolates harboured an 18 Md non-conjugative plasmid. He was dialysed peritoneally and treated with ampicillin; four days later there was no clinical improvement and his peritoneal dialysis fluid (PDF) had become infected. Salm. typhimurium was isolated from faeces and PDF. Both isolates were additionally resistant to ampicillin and contained two plasmids (55 Md and 18 Md). Therapy was changed to chloramphenicol and gentamicin was added to the PDF. Two weeks later Salm. typhimurium was again isolated from PDF and faeces. The PDF isolate was unchanged but 4% of the colonies isolated from this faecal specimen were resistant to chloramphenicol and had acquired an additional 62 Md plasmid. From all PDF and faecal specimens two different strains of Escherichia coli and one strain of Klebsiella pneumoniae were isolated which contained plasmids indistinguishable, on the basis of molecular weight and transferable resistance markers, from those acquired by Salm. typhimurium. The transferability of these plasmids in vitro to E. coli K12 and to the patient's initial Salm. typhimurium was studied and the results discussed.

  11. Solid state NMR sequential resonance assignments and conformational analysis of the 2x10.4 kDa dimeric form of the Bacillus subtilis protein Crh

    Energy Technology Data Exchange (ETDEWEB)

    Boeckmann, Anja [Institut de Biologie et Chimie des Proteines, C.N.R.S UMR 5086 (France)], E-mail: a.bockmann@ibcp.fr; Lange, Adam [Max-Planck-Institute for Biophysical Chemistry, Solid-state NMR (Germany); Galinier, Anne [Institut de Biologie Structurale et Microbiologie, C.N.R.S UPR 9043 (France); Luca, Sorin [Max-Planck-Institute for Biophysical Chemistry, Solid-state NMR (Germany); Giraud, Nicolas; Juy, Michel [Institut de Biologie et Chimie des Proteines, C.N.R.S UMR 5086 (France); Heise, Henrike [Max-Planck-Institute for Biophysical Chemistry, Solid-state NMR (Germany); Montserret, Roland; Penin, Francois [Institut de Biologie et Chimie des Proteines, C.N.R.S UMR 5086 (France); Baldus, Marc [Max-Planck-Institute for Biophysical Chemistry, Solid-state NMR (Germany)], E-mail: maba@mpibpc.mpg.de

    2003-12-15

    Solid state NMR sample preparation and resonance assignments of the U-[{sup 13}C,{sup 15}N] 2x10.4 kDa dimeric form of the regulatory protein Crh in microcrystalline, PEG precipitated form are presented. Intra- and interresidue correlations using dipolar polarization transfer methods led to nearly complete sequential assignments of the protein, and to 88% of all {sup 15}N, {sup 13}C chemical shifts. For several residues, the resonance assignments differ significantly from those reported for the monomeric form analyzed by solution state NMR. Dihedral angles obtained from a TALOS-based statistical analysis suggest that the microcrystalline arrangement of Crh must be similar to the domain-swapped dimeric structure of a single crystal form recently solved using X-ray crystallography. For a limited number of protein residues, a remarkable doubling of the observed NMR resonances is observed indicative of local static or dynamic conformational disorder. Our study reports resonance assignments for the largest protein investigated by solid state NMR so far and describes the conformational dimeric variant of Crh with previously unknown chemical shifts.

  12. Control and acquisition system of a space instrument for cosmic ray measurement

    Science.gov (United States)

    Prieto, M.; Martín, C.; Quesada, M.; Meziat, D.; Medina, J.; Sánchez, S.; Rodríguez-Frías, M. D.

    2000-04-01

    The PESCA Instrument Control and Acquisition System (PICAS) design, building and tests are presented. The purpose of the PESCA instrument is the study of the Solar Energetic Particles and the Anomalous Cosmic Rays. It is, therefore, a satellite on-board instrument. The PICAS is basically a computer, composed of a microprocessor with a memory block and a set of interfaces for the communication with the rest of the instrument and the satellite. The PICAS manages all the comunication processes with the satellite, that comprises the order reception from the ground station, and the telemetry sending, that includes scientific data and housekeeping data. By means of telecommands, the PICAS is completely controllable from the ground. The PICAS is also a reliable data acquisition system that guarantees the correct reception of the Cosmic Rays data collected in the ground.

  13. Easy measurement of diffusion coefficients of EGFP-tagged plasma membrane proteins using k-space Image Correlation Spectroscopy

    DEFF Research Database (Denmark)

    Christensen, Eva Arnspang; Koffman, Jennifer Skaarup; Marlar, Saw

    2014-01-01

    Lateral diffusion and compartmentalization of plasma membrane proteins are tightly regulated in cells and thus, studying these processes will reveal new insights to plasma membrane protein function and regulation. Recently, k-Space Image Correlation Spectroscopy (kICS)1 was developed to enable...... routine measurements of diffusion coefficients directly from images of fluorescently tagged plasma membrane proteins, that avoided systematic biases introduced by probe photophysics. Although the theoretical basis for the analysis is complex, the method can be implemented by nonexperts using a freely...... to the correlation function yields the diffusion coefficient. This paper provides a step-by-step guide to the image analysis and measurement of diffusion coefficients via kICS. First, a high frame rate image sequence of a fluorescently labeled plasma membrane protein is acquired using a fluorescence microscope Then...

  14. "Which Mouse Kissed the Frog?" Effects of Age of Onset, Length of Exposure, and Knowledge of Case Marking on the Comprehension of "Wh"-Questions in German-Speaking Simultaneous and Early Sequential Bilingual Children

    Science.gov (United States)

    Roesch, Anne Dorothee; Chondrogianni, Vasiliki

    2016-01-01

    Studies examining age of onset (AoO) effects in childhood bilingualism have provided mixed results as to whether early sequential bilingual children (eL2) differ from simultaneous bilingual children (2L1) and L2 children on the acquisition of morphosyntax. Differences between the three groups have been attributed to other factors such as length of…

  15. A motion correction algorithm for an image realignment programme useful for sequential radionuclide renography

    International Nuclear Information System (INIS)

    De Agostini, A.; Moretti, R.; Belletti, S.; Maira, G.; Magri, G.C.; Bestagno, M.

    1992-01-01

    The correction of organ movements in sequential radionuclide renography was done using an iterative algorithm that, by means of a set of rectangular regions of interest (ROIs), did not require any anatomical marker or manual elaboration of frames. The realignment programme here proposed is quite independent of the spatial and temporal distribution of activity and analyses the rotational movement in a simplified but reliable way. The position of the object inside a frame is evaluated by choosing the best ROI in a set of ROIs shifted 1 pixel around the central one. Statistical tests have to be fulfilled by the algorithm in order to activate the realignment procedure. Validation of the algorithm was done for different acquisition set-ups and organ movements. Results, summarized in Table 1, show that in about 90% of the stimulated experiments the algorithm is able to correct the movements of the object with a maximum error less of equal to 1 pixel limit. The usefulness of the realignment programme was demonstrated with sequential radionuclide renography as a typical clinical application. The algorithm-corrected curves of a 1-year-old patient were completely different from those obtained without a motion correction procedure. The algorithm may be applicable also to other types of scintigraphic examinations, besides functional imaging in which the realignment of frames of the dynamic sequence was an intrinsic demand. (orig.)

  16. Acquisition, processing and display of gated cardiac scintigrams

    International Nuclear Information System (INIS)

    Alpert, N.M.; Chesler, D.A.; McKusick, K.A.; Potsaid, M.S.; Pohost, G.M.; Dinsmore, R.A.

    1974-01-01

    An improved method for non-traumatic and essentially noninvasive evaluation of left ventricular (LV) function with /sup 99m/Tc as the tracer was developed. This method combines previously used EKG gating techniques for cardiac blood pool visualization with new computerized acquisition, processing and display techniques. An Anger camera, a small computer, and a physiological synchronizer are used to acquire a sequence of eight scintigrams which span the entire cardiac cycle. Under our present protocol two twenty-minute sequences are obtained, one an LAO (50 0 ) projection, the other an RAO (30 0 ) projection. Subsequently these images are processed on-line with a digital filter to increase definition of the cardiac borders. The eight images are then displayed sequentially on a specially designed electronic monitor to give an impression of the beating heart somewhat analogous to that obtained with invasive contrast angiography

  17. Flexible data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Clout, P N; Ridley, P A [Science Research Council, Daresbury (UK). Daresbury Lab.

    1978-06-01

    A data acquisition system has been developed which enables several independent experiments to be controlled by a 24 K word PDP-11 computer. Significant features of the system are the use of CAMAC, a high level language (RTL/2) and a general-purpose operating system executive which assist the rapid implementation of new experiments. This system has been used successfully for EXAFS and photo-electron spectroscopy experiments. It is intended to provide powerful concurrent data analysis and feedback facilities to the experimenter by on-line connection to the central IBM 370/165 computer.

  18. A SEQUENTIAL MODEL OF INNOVATION STRATEGY—COMPANY NON-FINANCIAL PERFORMANCE LINKS

    Directory of Open Access Journals (Sweden)

    Wakhid Slamet Ciptono

    2006-05-01

    dimensions of innovation strategy (partially mediators to company non-financial performance —productivity or operational reliability. The findings provide empirical evidence extending the previous model of Zahra and Das. These findings also provide a basis for useful recommendations to upstream and downstream SBU managers attempting to implement a sequential model of innovation strategy —company non-financial performance links. This study shows that upstream SBUs rely on external innovation sources. They will acquire innovation policies through business partnership development (such as Joint Operation Body for Enhanced Oil Recovery or JOB-EOR, Joint Operation Body for Production Sharing Contract or JOB-PSC; licensing agreements (Technical Assistance Contract or TAC, Consortium Cooperation System; or acquisition with other firms (Joint Operating Contract or JOC. In contrast, downstream SBUs emphasize on generating internal innovation sources to develop their own in-house R&D efforts. The downstream SBUs should make extensive policies of internal innovation sources in their attempts to control the distribution of oil-based fuel and transmission of natural gas for domestic and international markets effectively. Both policies would enhance understanding and ultimately contribute to the improvement of company financial performance —sales, net profit margin, return on assets.

  19. DATA ACQUISITION FOR SNS BEAM LOSS MONITOR SYSTEM

    International Nuclear Information System (INIS)

    YENG, Y.; GASSNER, D.; HOFF, L.; WITKOVER, R.

    2003-01-01

    The Spallation Neutron Source (SNS) beam loss monitor system uses VME based electronics to measure the radiation produced by lost beam. Beam loss signals from cylindrical argon-filled ion chambers and neutron detectors will be conditioned in analog front-end (AFE) circuitry. These signals will be digitized and further processed in a dedicated VME crate. Fast beam inhibit and low-level, long-term loss warnings will be generated to provide machine protection. The fast loss data will have a bandwidth of 35kHz. While the low level, long-term loss data will have much higher sensitivity. This is further complicated by the 3 decade range of intensity as the Ring accumulates beam. Therefore a bandwidth of 100kHz and dynamic range larger than 21 bits data acquisition system will be required for this purpose. Based on the evaluation of several commercial ADC modules in preliminary design phase, a 24 bits Sigma-Delta data acquisition VME bus card was chosen as the SNS BLM digitizer. An associated vxworks driver and EPICS device support module also have been developed at BNL. Simulating test results showed this system is fully qualified for both fast loss and low-level, long-term loss application. The first prototype including data acquisition hardware setup and EPICS software (running database and OPI clients) will be used in SNS Drift Tube Linac (DTL) system commissioning

  20. Tailoring the Acquisition Process in the U.S. Department of Defense

    Science.gov (United States)

    2015-01-01

    the associate directors, Paul DeLuca and Marc Robbins , for their insightful com- ments on this research. xvii Abbreviations ADM Acquisition Decision...by the SASSA program. Of these six, one was judged as a neutral contribution while five were judged as helpful in achiev- ing the program goals. No...tailored processes were judged as nega- tive contributions to meeting the rapid space acquisitions goals. (Johnson, 2010, p. 4) Also in regard to SE

  1. Sequential analysis in neonatal research-systematic review.

    Science.gov (United States)

    Lava, Sebastiano A G; Elie, Valéry; Ha, Phuong Thi Viet; Jacqz-Aigrain, Evelyne

    2018-05-01

    As more new drugs are discovered, traditional designs come at their limits. Ten years after the adoption of the European Paediatric Regulation, we performed a systematic review on the US National Library of Medicine and Excerpta Medica database of sequential trials involving newborns. Out of 326 identified scientific reports, 21 trials were included. They enrolled 2832 patients, of whom 2099 were analyzed: the median number of neonates included per trial was 48 (IQR 22-87), median gestational age was 28.7 (IQR 27.9-30.9) weeks. Eighteen trials used sequential techniques to determine sample size, while 3 used continual reassessment methods for dose-finding. In 16 studies reporting sufficient data, the sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674) with respect to a traditional trial. When the number of neonates finally included in the analysis was considered, the difference became significant: 35 (57%) patients (IQR 10 to 136.5, p = 0.0033). Sequential trial designs have not been frequently used in Neonatology. They might potentially be able to reduce the number of patients in drug trials, although this is not always the case. What is known: • In evaluating rare diseases in fragile populations, traditional designs come at their limits. About 20% of pediatric trials are discontinued, mainly because of recruitment problems. What is new: • Sequential trials involving newborns were infrequently used and only a few (n = 21) are available for analysis. • The sequential design allowed to non-significantly reduce the number of enrolled neonates by a median of 24 (31%) patients (IQR - 4.75 to 136.5, p = 0.0674).

  2. Metabolite-cycled density-weighted concentric rings k-space trajectory (DW-CRT) enables high-resolution 1 H magnetic resonance spectroscopic imaging at 3-Tesla.

    Science.gov (United States)

    Steel, Adam; Chiew, Mark; Jezzard, Peter; Voets, Natalie L; Plaha, Puneet; Thomas, Michael Albert; Stagg, Charlotte J; Emir, Uzay E

    2018-05-17

    Magnetic resonance spectroscopic imaging (MRSI) is a promising technique in both experimental and clinical settings. However, to date, MRSI has been hampered by prohibitively long acquisition times and artifacts caused by subject motion and hardware-related frequency drift. In the present study, we demonstrate that density weighted concentric ring trajectory (DW-CRT) k-space sampling in combination with semi-LASER excitation and metabolite-cycling enables high-resolution MRSI data to be rapidly acquired at 3 Tesla. Single-slice full-intensity MRSI data (short echo time (TE) semi-LASER TE = 32 ms) were acquired from 6 healthy volunteers with an in-plane resolution of 5 × 5 mm in 13 min 30 sec using this approach. Using LCModel analysis, we found that the acquired spectra allowed for the mapping of total N-acetylaspartate (median Cramer-Rao Lower Bound [CRLB] = 3%), glutamate+glutamine (8%), and glutathione (13%). In addition, we demonstrate potential clinical utility of this technique by optimizing the TE to detect 2-hydroxyglutarate (long TE semi-LASER, TE = 110 ms), to produce relevant high-resolution metabolite maps of grade III IDH-mutant oligodendroglioma in a single patient. This study demonstrates the potential utility of MRSI in the clinical setting at 3 Tesla.

  3. Group-sequential analysis may allow for early trial termination

    DEFF Research Database (Denmark)

    Gerke, Oke; Vilstrup, Mie H; Halekoh, Ulrich

    2017-01-01

    BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG-PET/CT mea......BACKGROUND: Group-sequential testing is widely used in pivotal therapeutic, but rarely in diagnostic research, although it may save studies, time, and costs. The purpose of this paper was to demonstrate a group-sequential analysis strategy in an intra-observer study on quantitative FDG...... assumed to be normally distributed, and sequential one-sided hypothesis tests on the population standard deviation of the differences against a hypothesised value of 1.5 were performed, employing an alpha spending function. The fixed-sample analysis (N = 45) was compared with the group-sequential analysis...... strategies comprising one (at N = 23), two (at N = 15, 30), or three interim analyses (at N = 11, 23, 34), respectively, which were defined post hoc. RESULTS: When performing interim analyses with one third and two thirds of patients, sufficient agreement could be concluded after the first interim analysis...

  4. Comparison of ablation centration after bilateral sequential versus simultaneous LASIK.

    Science.gov (United States)

    Lin, Jane-Ming; Tsai, Yi-Yu

    2005-01-01

    To compare ablation centration after bilateral sequential and simultaneous myopic LASIK. A retrospective randomized case series was performed of 670 eyes of 335 consecutive patients who had undergone either bilateral sequential (group 1) or simultaneous (group 2) myopic LASIK between July 2000 and July 2001 at the China Medical University Hospital, Taichung, Taiwan. The ablation centrations of the first and second eyes in the two groups were compared 3 months postoperatively. Of 670 eyes, 274 eyes (137 patients) comprised the sequential group and 396 eyes (198 patients) comprised the simultaneous group. Three months post-operatively, 220 eyes of 110 patients (80%) in the sequential group and 236 eyes of 118 patients (60%) in the simultaneous group provided topographic data for centration analysis. For the first eyes, mean decentration was 0.39 +/- 0.26 mm in the sequential group and 0.41 +/- 0.19 mm in the simultaneous group (P = .30). For the second eyes, mean decentration was 0.28 +/- 0.23 mm in the sequential group and 0.30 +/- 0.21 mm in the simultaneous group (P = .36). Decentration in the second eyes significantly improved in both groups (group 1, P = .02; group 2, P sequential group and 0.32 +/- 0.18 mm in the simultaneous group (P = .33). The difference of ablation center angles between the first and second eyes was 43.2 sequential group and 45.1 +/- 50.8 degrees in the simultaneous group (P = .42). Simultaneous bilateral LASIK is comparable to sequential surgery in ablation centration.

  5. A Survey of Multi-Objective Sequential Decision-Making

    NARCIS (Netherlands)

    Roijers, D.M.; Vamplew, P.; Whiteson, S.; Dazeley, R.

    2013-01-01

    Sequential decision-making problems with multiple objectives arise naturally in practice and pose unique challenges for research in decision-theoretic planning and learning, which has largely focused on single-objective settings. This article surveys algorithms designed for sequential

  6. Sequential lineups: shift in criterion or decision strategy?

    Science.gov (United States)

    Gronlund, Scott D

    2004-04-01

    R. C. L. Lindsay and G. L. Wells (1985) argued that a sequential lineup enhanced discriminability because it elicited use of an absolute decision strategy. E. B. Ebbesen and H. D. Flowe (2002) argued that a sequential lineup led witnesses to adopt a more conservative response criterion, thereby affecting bias, not discriminability. Height was encoded as absolute (e.g., 6 ft [1.83 m] tall) or relative (e.g., taller than). If a sequential lineup elicited an absolute decision strategy, the principle of transfer-appropriate processing predicted that performance should be best when height was encoded absolutely. Conversely, if a simultaneous lineup elicited a relative decision strategy, performance should be best when height was encoded relatively. The predicted interaction was observed, providing direct evidence for the decision strategies explanation of what happens when witnesses view a sequential lineup.

  7. The Challenge of Space Infrastructure Construction

    Science.gov (United States)

    Howe, A. Scott; Colombano, Silvano P.

    2010-01-01

    This paper reviews the range of technologies that will contribute to the construction of space infrastructure that will both enable and, in some cases, provide the motivation for space exploration. Five parts are addressed: Managing complexity, robotics based construction, materials acquisition, manufacturing, and self-sustaining systems.

  8. Further Developments on Optimum Structural Design Using MSC/Nastran and Sequential Quadratic Programming

    DEFF Research Database (Denmark)

    Holzleitner, Ludwig

    1996-01-01

    , here the shape of two dimensional parts with different thickness areas will be optimized. As in the previos paper, a methodology for structural optimization using the commercial finite element package MSC/NASTRAN for structural analysis is described. Three different methods for design sensitivity......This work is closely connected to the paper: K.G. MAHMOUD, H.W. ENGL and HOLZLEITNER: "OPTIMUM STRUCTURAL DESIGN USING MSC/NASTRAN AND SEQUENTIAL QUADRATIC PROGRAMMING", Computers & Structures, Vol. 52, No. 3, pp. 437-447, (1994). In contrast to that paper, where thickness optimization is described...

  9. An Experimental Study of the Decay $D^0 \\to K^- K^- K^+ \\pi^+$

    Energy Technology Data Exchange (ETDEWEB)

    Devmal, Shiral Cleophas [Cincinnati U.

    2000-05-01

    Using data from the E791 experiment at Fermi National Accelerator Laboratory (Fermilab), we have studied the Cabibbo favored, but phase space suppressed decay $D^0 \\to K^-K^- K^+ \\pi^+$ with the normalization channel $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$. We report the branching ratio of $D^0 \\to K^- K^- K^+ \\pi^+$ relative to the branching ratio of $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$. This value is (0.54 $\\pm$ 0.13 $\\pm$ 0.07)%. We see a clear signal of $K^-K^+$ resonance in the decay $D^0 \\to K^-K^-K^+\\pi^+$ from which we conclude that about (60 $\\pm$ 30)% of $KKK\\pi$ comes from $D^0 \\to \\phi K^-\\pi^+; \\phi \\to K^-K^+$. We also set the range (0.30% - 0.90%) for the ratio $P_{q\\overline{q}} = P_{NoPop}$ where $P_{q\\bar{q}}$ is the contribution from either $D^0 \\to K^-K^-K^+\\pi^+$ terms that pop an $s\\bar{s}$ or corresponding $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$ terms that pop either $u\\bar{u}$ or $d\\bar{d}$ pair and $P_{NoPop}$ is the contributions from the $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$ terms that do not have such corresponding popping.

  10. Magnetic Field Response Measurement Acquisition System

    Science.gov (United States)

    Woodard, Stanley E.; Taylor,Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2007-01-01

    This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

  11. TU-AB-BRA-09: A Novel Method of Generating Ultrafast Volumetric Cine MRI (VC-MRI) Using Prior 4D-MRI and On-Board Phase-Skipped Encoding Acquisition for Radiotherapy Target Localization

    Energy Technology Data Exchange (ETDEWEB)

    Wang, C; Yin, F; Harris, W; Cai, J; Chang, Z; Ren, L [Duke University Medical Center, Durham, NC (United States)

    2016-06-15

    Purpose: To develop a technique generating ultrafast on-board VC-MRI using prior 4D-MRI and on-board phase-skipped encoding k-space acquisition for real-time 3D target tracking of liver and lung radiotherapy. Methods: The end-of-expiration (EOE) volume in 4D-MRI acquired during the simulation was selected as the prior volume. 3 major respiratory deformation patterns were extracted through the principal component analysis of the deformation field maps (DFMs) generated between EOE and all other phases. The on-board VC-MRI at each instant was considered as a deformation of the prior volume, and the deformation was modeled as a linear combination of the extracted 3 major deformation patterns. To solve the weighting coefficients of the 3 major patterns, a 2D slice was extracted from VC-MRI volume to match with the 2D on-board sampling data, which was generated by 8-fold phase skipped-encoding k-space acquisition (i.e., sample 1 phase-encoding line out of every 8 lines) to achieve an ultrafast 16–24 volumes/s frame rate. The method was evaluated using XCAT digital phantom to simulate lung cancer patients. The 3D volume of end-ofinhalation (EOI) phase at the treatment day was used as ground-truth onboard VC-MRI with simulated changes in 1) breathing amplitude and 2) breathing amplitude/phase change from the simulation day. A liver cancer patient case was evaluated for in-vivo feasibility demonstration. Results: The comparison between ground truth and estimated on-board VC-MRI shows good agreements. In XCAT study with changed breathing amplitude, the volume-percent-difference(VPD) between ground-truth and estimated tumor volumes at EOI was 6.28% and the Center-of-Mass-Shift(COMS) was 0.82mm; with changed breathing amplitude and phase, the VPD was 8.50% and the COMS was 0.54mm. The study of liver patient case also demonstrated a promising in vivo feasibility of the proposed method Conclusion: Preliminary results suggest the feasibility to estimate ultrafast VC-MRI for on

  12. TU-AB-BRA-09: A Novel Method of Generating Ultrafast Volumetric Cine MRI (VC-MRI) Using Prior 4D-MRI and On-Board Phase-Skipped Encoding Acquisition for Radiotherapy Target Localization

    International Nuclear Information System (INIS)

    Wang, C; Yin, F; Harris, W; Cai, J; Chang, Z; Ren, L

    2016-01-01

    Purpose: To develop a technique generating ultrafast on-board VC-MRI using prior 4D-MRI and on-board phase-skipped encoding k-space acquisition for real-time 3D target tracking of liver and lung radiotherapy. Methods: The end-of-expiration (EOE) volume in 4D-MRI acquired during the simulation was selected as the prior volume. 3 major respiratory deformation patterns were extracted through the principal component analysis of the deformation field maps (DFMs) generated between EOE and all other phases. The on-board VC-MRI at each instant was considered as a deformation of the prior volume, and the deformation was modeled as a linear combination of the extracted 3 major deformation patterns. To solve the weighting coefficients of the 3 major patterns, a 2D slice was extracted from VC-MRI volume to match with the 2D on-board sampling data, which was generated by 8-fold phase skipped-encoding k-space acquisition (i.e., sample 1 phase-encoding line out of every 8 lines) to achieve an ultrafast 16–24 volumes/s frame rate. The method was evaluated using XCAT digital phantom to simulate lung cancer patients. The 3D volume of end-ofinhalation (EOI) phase at the treatment day was used as ground-truth onboard VC-MRI with simulated changes in 1) breathing amplitude and 2) breathing amplitude/phase change from the simulation day. A liver cancer patient case was evaluated for in-vivo feasibility demonstration. Results: The comparison between ground truth and estimated on-board VC-MRI shows good agreements. In XCAT study with changed breathing amplitude, the volume-percent-difference(VPD) between ground-truth and estimated tumor volumes at EOI was 6.28% and the Center-of-Mass-Shift(COMS) was 0.82mm; with changed breathing amplitude and phase, the VPD was 8.50% and the COMS was 0.54mm. The study of liver patient case also demonstrated a promising in vivo feasibility of the proposed method Conclusion: Preliminary results suggest the feasibility to estimate ultrafast VC-MRI for on

  13. How to Read the Tractatus Sequentially

    Directory of Open Access Journals (Sweden)

    Tim Kraft

    2016-11-01

    Full Text Available One of the unconventional features of Wittgenstein’s Tractatus Logico-Philosophicus is its use of an elaborated and detailed numbering system. Recently, Bazzocchi, Hacker und Kuusela have argued that the numbering system means that the Tractatus must be read and interpreted not as a sequentially ordered book, but as a text with a two-dimensional, tree-like structure. Apart from being able to explain how the Tractatus was composed, the tree reading allegedly solves exegetical issues both on the local (e. g. how 4.02 fits into the series of remarks surrounding it and the global level (e. g. relation between ontology and picture theory, solipsism and the eye analogy, resolute and irresolute readings. This paper defends the sequential reading against the tree reading. After presenting the challenges generated by the numbering system and the two accounts as attempts to solve them, it is argued that Wittgenstein’s own explanation of the numbering system, anaphoric references within the Tractatus and the exegetical issues mentioned above do not favour the tree reading, but a version of the sequential reading. This reading maintains that the remarks of the Tractatus form a sequential chain: The role of the numbers is to indicate how remarks on different levels are interconnected to form a concise, surveyable and unified whole.

  14. Basic evaluation of the new pulse sequence for simultaneous acquisition of T1- and T2-weighted images

    International Nuclear Information System (INIS)

    Kurose, Atsunari; Takahashi, Tohru; Ohishi, Tae; Ishikawa, Akihiro

    2006-01-01

    A novel pulse sequence that enables simultaneous acquisition of T1-weighted (T1W) and T2-weighted (T2W) images is presented. In this new technique, the inversion recovery (IR) pulse of conventional fast inversion recovery (Fast IR) is replaced with a pulse train that consists of a fast spin echo (FSE) and 180(y)+90(x) for driven inversion (DI). By using a shorter T1 and independent k-space ordering, the first part of the sequence provides T2W images and the second part provides T1W images, thereby enabling simultaneous acquisition in a single scan time comparable to that of Fast IR. Signal simulation also was conducted, and this was compared with conventional scanning techniques using normal volunteers. In the human studies, both T1W and T2W images showed the same image quality as conventional images, suggesting the potential for this technique to replace the combination of Fast IR and T2W FSE for scan-time reduction. (author)

  15. Projective Dimension in Filtrated K-Theory

    DEFF Research Database (Denmark)

    Bentmann, Rasmus Moritz

    2013-01-01

    Under mild assumptions, we characterise modules with projective resolutions of length n∈N in the target category of filtrated K-theory over a finite topological space in terms of two conditions involving certain Tor -groups. We show that the filtrated K-theory of any separable C∗dash-algebra over...... any topological space with at most four points has projective dimension 2 or less. We observe that this implies a universal coefficient theorem for rational equivariant KK-theory over these spaces. As a contrasting example, we find a separable C∗dash-algebra in the bootstrap class over a certain five......-point space, the filtrated K-theory of which has projective dimension 3. Finally, as an application of our investigations, we exhibit Cuntz-Krieger algebras which have projective dimension 2 in filtrated K-theory over their respective primitive spectrum....

  16. A minimax procedure in the context of sequential mastery testing

    NARCIS (Netherlands)

    Vos, Hendrik J.

    1999-01-01

    The purpose of this paper is to derive optimal rules for sequential mastery tests. In a sequential mastery test, the decision is to classify a subject as a master or a nonmaster, or to continue sampling and administering another random test item. The framework of minimax sequential decision theory

  17. Evolution of systems concepts for a 100 kWe class space nuclear power system

    International Nuclear Information System (INIS)

    Katucki, R.; Josloff, A.; Kirpich, A.; Florio, F.

    1985-01-01

    Conceptual designs for the SP-100 space nuclear power system have been prepared that meet baseline, backup and growth program scenarios. Near-term advancement in technology was considered in the design of the baseline concept. An improved silicon-germanium thermoelectric technique is used to convert the heat from a fast-spectrum, liquid lithium cooled reactor. This system produces a net power of 100 kWe with a 10-year end of life, under the specific constraints of area and volume. Output of the backup concept is estimated to be 60 kWe for a 10-year end of life. This system differs from the naseline concept because currently available thermoelectric conversion is used from energy supplied by a liquid sodium cooled reactor. The growth concept uses Stirling engine conversion to produce 100 kWe within the constraints of mass and volume. The growth concept can be scaled up to produce a 1 MWe output that uses the same type reactor developed for the baseline concept. Assessments made for each of the program scenarios indicate the key development efforts needed to initiate detailed design and hardware program phases. Development plans were prepared for each scenario that detail the work elements and show the program activities leading to a state of flight readiness

  18. Evolution of systems concepts for a 100 kWe class Space Nuclear Power System

    Science.gov (United States)

    Katucki, R.; Josloff, A.; Kirpich, A.; Florio, F.

    1985-01-01

    Conceptual designs for the SP-100 Space Nuclear Power System have been prepared that meet baseline, backup and growth program scenarios. Near-term advancement in technology was considered in the design of the Baseline Concept. An improved silicon-germanium thermoelectric technique is used to convert the heat from a fast-spectrum, liquid lithium cooled reactor. This system produces a net power of 100 kWe with a 10-year end of life, under the specific constraints of area and volume. Output of the Backup Concept is estimated to be 60 kWe for a 10-year end of life. This system differs from the Baseline Concept because currently available thermoelectric conversion is used from energy supplied by a liquid sodium cooled reactor. The Growth Concept uses Stirling engine conversion to produce 100 kWe within the constraints of mass and volume. The Growth Concept can be scaled up to produce a 1 MWe output that uses the same type reactor developed for the Baseline Concept. Assessments made for each of the program scenarios indicate the key development efforts needed to initiate detailed design and hardware program phases. Development plans were prepared for each scenario that detail the work elements and show the program activities leading to a state of flight readiness.

  19. XQ-NLM: Denoising Diffusion MRI Data via x-q Space Non-Local Patch Matching.

    Science.gov (United States)

    Chen, Geng; Wu, Yafeng; Shen, Dinggang; Yap, Pew-Thian

    2016-10-01

    Noise is a major issue influencing quantitative analysis in diffusion MRI. The effects of noise can be reduced by repeated acquisitions, but this leads to long acquisition times that can be unrealistic in clinical settings. For this reason, post-acquisition denoising methods have been widely used to improve SNR. Among existing methods, non-local means (NLM) has been shown to produce good image quality with edge preservation. However, currently the application of NLM to diffusion MRI has been mostly focused on the spatial space (i.e., the x -space), despite the fact that diffusion data live in a combined space consisting of the x -space and the q -space (i.e., the space of wavevectors). In this paper, we propose to extend NLM to both x -space and q -space. We show how patch-matching, as required in NLM, can be performed concurrently in x-q space with the help of azimuthal equidistant projection and rotation invariant features. Extensive experiments on both synthetic and real data confirm that the proposed x-q space NLM (XQ-NLM) outperforms the classic NLM.

  20. Post-Newtonian equations of motion for LEO debris objects and space-based acquisition, pointing and tracking laser systems

    Science.gov (United States)

    Gambi, J. M.; García del Pino, M. L.; Gschwindl, J.; Weinmüller, E. B.

    2017-12-01

    This paper deals with the problem of throwing middle-sized low Earth orbit debris objects into the atmosphere via laser ablation. The post-Newtonian equations here provided allow (hypothetical) space-based acquisition, pointing and tracking systems endowed with very narrow laser beams to reach the pointing accuracy presently prescribed. In fact, whatever the orbital elements of these objects may be, these equations will allow the operators to account for the corrections needed to balance the deviations of the line of sight directions due to the curvature of the paths the laser beams are to travel along. To minimize the respective corrections, the systems will have to perform initial positioning manoeuvres, and the shooting point-ahead angles will have to be adapted in real time. The enclosed numerical experiments suggest that neglecting these measures will cause fatal errors, due to differences in the actual locations of the objects comparable to their size.

  1. Experimental MR-guided cryotherapy of the brain with almost real-time imaging by radial k-space scanning; Experimentelle MR-gesteuerte Kryotherapie des Gehirns mit nahezu Echtzeitdarstellung durch radiale k-Raum-Abtastung

    Energy Technology Data Exchange (ETDEWEB)

    Tacke, J.; Schorn, R.; Glowinski, A.; Grosskortenhaus, S.; Adam, G.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Speetzen, R.; Rau, G. [Helmholtz-Institut fuer Biomedizinische Technik, Aachen (Germany); Rasche, V. [Philips GmbH Forschungslaboratorium, Hamburg (Germany)

    1999-02-01

    Purpose: To test radial k-space scanning by MR fluoroscopy to guide and control MR-guided interstitial cryotherapy of the healthy pig brain. Methods: After MR tomographic planning of the approach, an MR-compatible experimental cryotherapy probe of 2.7 mm diameter was introduced through a 5 mm burr hole into the right frontal brain of five healthy pigs. The freeze-thaw cycles were imaged using a T{sub 1}-weighted gradient echo sequence with radial k-space scanning in coronal, sagittal, and axial directions. Results: The high temporal resolution of the chosen sequence permits a continuous representation of the freezing process with good image quality and high contrast between ice and unfrozen brain parenchyma. Because of the interactive conception of the sequence the layer plane could be chosen as desired during the measurement. Ice formation was sharply demarcated, spherically configurated, and was free of signals. Its maximum diameter was 13 mm. Conclusions: With use of the novel, interactively controllable gradient echo sequence with radial k-space scanning, guidance of the intervention under fluoroscopic conditions with the advantages of MRT is possible. MR-guided cryotherapy allows a minimally-invasive, precisely dosable focal tissue ablation. (orig.) [Deutsch] Ziel: Erprobung der radialen k-Raum-Abtastung bei der MR-Fluoroskopie zur Steuerung und Kontrolle MR-gesteuerter interstitieller Kryotherapie des gesunden Schweinegehirns. Methoden: Nach MR-tomographischer Planung des Zugangsweges wurde eine MR-kompatible experimentelle Kryotherapiesonde von 2,7 mm Durchmesser ueber ein 5 mm Bohrloch in das rechte Frontalhirn von fuenf gesunden Schweinen eingebracht. Die Frier-/Tauzyklen wurden anhand einer T{sub 1}-gewichteten Gradientenechosequenz mit radialer k-Raum-Abtastung in koronarer, sagittaler und axialer Schichtfuehrung dargestellt. Ergebnisse: Die hohe zeitliche Aufloesung der gewaehlten Sequenz erlaubte eine kontinuierliche Darstellung des Friervorgangs bei

  2. Multichannel, sequential or combined X-ray spectrometry

    International Nuclear Information System (INIS)

    Florestan, J.

    1979-01-01

    X-ray spectrometer qualities and defects are evaluated for sequential and multichannel categories. Multichannel X-ray spectrometer has time-coherency advantage and its results could be more reproducible; on the other hand some spatial incoherency limits low percentage and traces applications, specially when backgrounds are very variable. In this last case, sequential X-ray spectrometer would find again great usefulness [fr

  3. Induction of simultaneous and sequential malolactic fermentation in durian wine.

    Science.gov (United States)

    Taniasuri, Fransisca; Lee, Pin-Rou; Liu, Shao-Quan

    2016-08-02

    This study represented for the first time the impact of malolactic fermentation (MLF) induced by Oenococcus oeni and its inoculation strategies (simultaneous vs. sequential) on the fermentation performance as well as aroma compound profile of durian wine. There was no negative impact of simultaneous inoculation of O. oeni and Saccharomyces cerevisiae on the growth and fermentation kinetics of S. cerevisiae as compared to sequential fermentation. Simultaneous MLF did not lead to an excessive increase in volatile acidity as compared to sequential MLF. The kinetic changes of organic acids (i.e. malic, lactic, succinic, acetic and α-ketoglutaric acids) varied with simultaneous and sequential MLF relative to yeast alone. MLF, regardless of inoculation mode, resulted in higher production of fermentation-derived volatiles as compared to control (alcoholic fermentation only), including esters, volatile fatty acids, and terpenes, except for higher alcohols. Most indigenous volatile sulphur compounds in durian were decreased to trace levels with little differences among the control, simultaneous and sequential MLF. Among the different wines, the wine with simultaneous MLF had higher concentrations of terpenes and acetate esters while sequential MLF had increased concentrations of medium- and long-chain ethyl esters. Relative to alcoholic fermentation only, both simultaneous and sequential MLF reduced acetaldehyde substantially with sequential MLF being more effective. These findings illustrate that MLF is an effective and novel way of modulating the volatile and aroma compound profile of durian wine. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Sequential Banking.

    OpenAIRE

    Bizer, David S; DeMarzo, Peter M

    1992-01-01

    The authors study environments in which agents may borrow sequentially from more than one leader. Although debt is prioritized, additional lending imposes an externality on prior debt because, with moral hazard, the probability of repayment of prior loans decreases. Equilibrium interest rates are higher than they would be if borrowers could commit to borrow from at most one bank. Even though the loan terms are less favorable than they would be under commitment, the indebtedness of borrowers i...

  5. Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blanke, Philipp; Baumann, Tobias; Langer, Mathias; Pache, Gregor [University Hospital Freiburg, Department of Diagnostic Radiology, Freiburg (Germany)

    2010-08-15

    To prospectively investigate the feasibility, image quality and radiation dose estimates for computed tomography angiography (CTA) of the pulmonary veins and left atrium using prospective electrocardiography (ECG)-triggered sequential dual-source (DS) data acquisition at end-systole in patients with paroxysmal atrial fibrillation undergoing radiofrequency ablation. Thirty-five patients (mean age 66.2 {+-} 12.6 years) with paroxysmal atrial fibrillation underwent prospective ECG-triggered sequential DS-CTA with tube current (250 mAs/rotation) centred 250 ms past the R-peak. Tube voltage was adjusted to the BMI (<25 kg/m{sup 2}: 100 kV, >25 kg/m{sup 2}: 120 kV). Presence of motion or stair-step artefacts was assessed. Effective radiation dose was calculated from the dose-length product. All data sets could be integrated into the electroanatomical mapping system. Twenty-two patients (63%) were in sinus rhythm (mean heart rate 69.2 {+-} 11.1 bpm, variability 1.0 {+-} 1.7 bpm) and 13 (37%) showed an ECG pattern of atrial fibrillation (mean heart rate 84.8 {+-} 16.6 bpm, variability 17.9 {+-} 7.5 bpm). Minor step artefacts were observed in three patients (23%) with atrial fibrillation. Mean estimated effective dose was 1.1 {+-} 0.3 and 3.0 {+-} 0.5 mSv for 100 and 120 kV respectively. Imaging of pulmonary vein anatomy is feasible using prospective ECG-triggered sequential data acquisition at end-systole regardless of heart rate or rhythm at the benefit of low radiation dose. (orig.)

  6. Invariant subspaces in some function spaces on symmetric spaces. II

    International Nuclear Information System (INIS)

    Platonov, S S

    1998-01-01

    Let G be a semisimple connected Lie group with finite centre, K a maximal compact subgroup of G, and M=G/K a Riemannian symmetric space of non-compact type. We study the problem of describing the structure of closed linear subspaces in various function spaces on M that are invariant under the quasiregular representation of the group G. We consider the case when M is a symplectic symmetric space of rank 1

  7. A high-speed CAMAC data acquisition system for PDP-11

    International Nuclear Information System (INIS)

    Berg, D.M.; Heinicke, P.; Quigg, L.

    1985-01-01

    This paper describes a high-speed data acquisition system for a PDP-11 running under the RSX-11M operating system. It has been used by several high-energy physics experiments at Fermilab. The system consists of several coordinated tasks which acquire data through a CAMAC interface, log data to magnetic tape, supply data to independent monitoring and analysis tasks (such as RSXMULTI), and perform control functions. A data buffer extending beyond the 18-bit address space of the PDP-11 is implemented using Konelar bank-switchable memory. Supported configurations range from small systems with single data acquisition and analysis tasks on the same processor, to large multi-processor systems with data acquisition on several PDPs and analysis on separate PDPs or VAXs

  8. Equivalence between quantum simultaneous games and quantum sequential games

    OpenAIRE

    Kobayashi, Naoki

    2007-01-01

    A framework for discussing relationships between different types of games is proposed. Within the framework, quantum simultaneous games, finite quantum simultaneous games, quantum sequential games, and finite quantum sequential games are defined. In addition, a notion of equivalence between two games is defined. Finally, the following three theorems are shown: (1) For any quantum simultaneous game G, there exists a quantum sequential game equivalent to G. (2) For any finite quantum simultaneo...

  9. The cobordism category and Waldhausen's K-theory

    DEFF Research Database (Denmark)

    Bökstedt, M.; Madsen, Ib

    This paper examines the category C^k_{d,n} whose morphisms are d-dimensional smooth manifolds that are properly embedded in the product of a k-dimensional cube with an (d+n-k)-dimensional Euclidean space. There are k directions to compose k-dimensional cubes, so C^k_{d,n} is a (strict) k-tuple ca......-tuple category. The geometric realization of the k-dimensional multi-nerve is the classifying space BC^k_{d,n}. At the end of the paper we construct an infinite loop map to Waldhausens K-theory. \\Omega BC^1_{d,n}-> A(BO(d)), We believe that the map factors through \\Omega...

  10. Accounting for Heterogeneous Returns in Sequential Schooling Decisions

    NARCIS (Netherlands)

    Zamarro, G.

    2006-01-01

    This paper presents a method for estimating returns to schooling that takes into account that returns may be heterogeneous among agents and that educational decisions are made sequentially.A sequential decision model is interesting because it explicitly considers that the level of education of each

  11. Simultaneous Versus Sequential Ptosis and Strabismus Surgery in Children.

    Science.gov (United States)

    Revere, Karen E; Binenbaum, Gil; Li, Jonathan; Mills, Monte D; Katowitz, William R; Katowitz, James A

    The authors sought to compare the clinical outcomes of simultaneous versus sequential ptosis and strabismus surgery in children. Retrospective, single-center cohort study of children requiring both ptosis and strabismus surgery on the same eye. Simultaneous surgeries were performed during a single anesthetic event; sequential surgeries were performed at least 7 weeks apart. Outcomes were ptosis surgery success (margin reflex distance 1 ≥ 2 mm, good eyelid contour, and good eyelid crease); strabismus surgery success (ocular alignment within 10 prism diopters of orthophoria and/or improved head position); surgical complications; and reoperations. Fifty-six children were studied, 38 had simultaneous surgery and 18 sequential. Strabismus surgery was performed first in 38/38 simultaneous and 6/18 sequential cases. Mean age at first surgery was 64 months, with mean follow up 27 months. A total of 75% of children had congenital ptosis; 64% had comitant strabismus. A majority of ptosis surgeries were frontalis sling (59%) or Fasanella-Servat (30%) procedures. There were no significant differences between simultaneous and sequential groups with regards to surgical success rates, complications, or reoperations (all p > 0.28). In the first comparative study of simultaneous versus sequential ptosis and strabismus surgery, no advantage for sequential surgery was seen. Despite a theoretical risk of postoperative eyelid malposition or complications when surgeries were performed in a combined manner, the rate of such outcomes was not increased with simultaneous surgeries. Performing ptosis and strabismus surgery together appears to be clinically effective and safe, and reduces anesthesia exposure during childhood.

  12. Forced Sequence Sequential Decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis

    In this thesis we describe a new concatenated decoding scheme based on iterations between an inner sequentially decoded convolutional code of rate R=1/4 and memory M=23, and block interleaved outer Reed-Solomon codes with non-uniform profile. With this scheme decoding with good performance...... is possible as low as Eb/No=0.6 dB, which is about 1.7 dB below the signal-to-noise ratio that marks the cut-off rate for the convolutional code. This is possible since the iteration process provides the sequential decoders with side information that allows a smaller average load and minimizes the probability...... of computational overflow. Analytical results for the probability that the first Reed-Solomon word is decoded after C computations are presented. This is supported by simulation results that are also extended to other parameters....

  13. Technical Performance Assessment: Mission Success in Software Acquisition Management

    Science.gov (United States)

    2010-04-27

    Examples Design constraints make software acquisition and development t l iti lex reme y cr ca Application domain – Operational Flight Program, Air...environment – used to produce the software Ri k t t bli h d d i t i d i k ts managemen – es a s e an ma n a ne r s managemen systems Milestone reviews...Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that

  14. Enterprise Requirements and Acquisition Model (ERAM) Analysis and Extension

    Science.gov (United States)

    2014-02-20

    lean concept into the earlier phases of acquisition (e.g., before the Milestone C [MS-C] review [Labedz, Initiative, & Harvey , 2006; Moorman, 2005...47 - k~î~ä=mçëíÖê~Çì~íÉ=pÅÜççä= Labedz, C. S., Jr., Initiative, L. A., & Harvey , R. K. (2006). Letterkenny Army Depot: Finance innovations support...Chandler, 2006). The launch manifest process is outlined in AFSPCI10-1213, Launch Scheduling and Forecasting Procedures ( Weinstein , 2012) and AFSPC

  15. K-edge Radiography and applications to Cultural Heritage

    OpenAIRE

    Albertin, Fauzia

    2011-01-01

    The present work of thesis is focused on application of X-ray K-edge technique to paintings. This technique allows one to achieve a topographic map of a pigment on the whole surface of the painting. The digital acquisition of radiographic images by using monochromatic X-ray beams allows to take advantage of the sharp rise of X-ray absorption coefficient of the elements, the K-edge discontinuity. Working at different energies, bracketing the K-edge peak, allows recognition ...

  16. Department of Defense Enterprise Requirements and Acquisition Model

    Science.gov (United States)

    2011-06-01

    30  Figure 11: ExtendSim Icons ...collected through a series of interviews with space requirements and acquisition personnel from AFSPC Requirements directorate (AFSPC/ A5 ), the Under...of the many ExtendSim® icons are described and illustrated in Figure 11. The “Event/Activity” icon is implemented with a time duration allowing a

  17. On the acquisition of temporal conjunctions in Finnish.

    Science.gov (United States)

    Atanassova, M

    2001-03-01

    This study concerns the acquisition of complex sentence structures in Finnish. Specifically, three simultaneous and sequential events were acted out with toys in an elicitation task, and the production of "and," "and then," "when," and "after" were observed. There were 48 children in a cross-sectional design at the age levels 3, 4, 5, and 6 years. Immediately after the complex event was presented, the child was asked the initial request "What happened?" If the child did not produce the whole event spontaneously, she or he was prompted by "What else happened?" Finally, the prompted request "When did X?" was asked (X referring to the second action component of the event). The results showed that prompting better revealed the ability of the children, especially that of the younger ones, to use temporal conjunctions in complex sentences, as well as the delicate interplay of language skills and their flexible use.

  18. Reading Remediation Based on Sequential and Simultaneous Processing.

    Science.gov (United States)

    Gunnison, Judy; And Others

    1982-01-01

    The theory postulating a dichotomy between sequential and simultaneous processing is reviewed and its implications for remediating reading problems are reviewed. Research is cited on sequential-simultaneous processing for early and advanced reading. A list of remedial strategies based on the processing dichotomy addresses decoding and lexical…

  19. The JET diagnostic fast central acquisition and trigger system (abstract)

    Science.gov (United States)

    Edwards, A. W.; Blackler, K.

    1995-01-01

    Most plasma physics diagnostics sample at a fixed frequency that is normally matched to available memory limits. This technique is not appropriate for long pulse machines such as JET where sampling frequencies of hundreds of kHz are required to diagnose very fast events. As a result of work using real-time event selection within the previous JET soft x-ray diagnostic, a single data acquisition and event triggering system for all suitable fast diagnostics, the fast central acquisition and trigger system (Fast CATS), has been developed for JET. The front-end analog-to-digital conversion (ADC) part samples all channels at 250 kHz, with a 100 kHz pass band and a stop band of 125 kHz. The back-end data collection system is based around Texas Instruments TMS320C40 microprocessors. Within this system, two levels of trigger algorithms are able to evaluate data. The first level typically analyzes data on a per diagnostic and individual channel basis. The second level looks at the data from one or more diagnostics in a window around the time of interest flagged by the first level system. Selection criteria defined by the diagnosticians are then imposed on the results from the second level to decide whether that data should be kept. The use of such a system involving intelligent real time trigger algorithms and fast data analysis will improve both the quantity and quality of JET diagnostic data, while providing valuable input to the design of data acquisition systems for very long pulse machines such as ITER. This paper will give an overview of the various elements of this new system. In addition, first results from this system following the restart of JET operation will be presented.

  20. Reference-free unwarping of single-shot spatiotemporally encoded MRI using asymmetric self-refocused echoes acquisition

    Science.gov (United States)

    Chen, Ying; Chen, Song; Zhong, Jianhui; Chen, Zhong

    2015-05-01

    This paper presents a phase evolution rewinding algorithm for correcting the geometric and intensity distortions in single-shot spatiotemporally encoded (SPEN) MRI with acquisition of asymmetric self-refocused echo trains. Using the field map calculated from the phase distribution of the source image, the off-resonance induced phase errors are successfully rewound through deconvolution. The alias-free partial Fourier transform reconstruction helps improve the signal-to-noise ratio of the field maps and the output images. The effectiveness of the proposed algorithm was validated through 7 T MRI experiments on a lemon, a water phantom, and in vivo rat head. SPEN imaging was evaluated using rapid acquisition by sequential excitation and refocusing (RASER) which produces uniform T2 weighting. The results indicate that the new technique can more robustly deal with the cases in which the images obtained with conventional single-shot spin-echo EPI are difficult to be restored due to serious field variations.

  1. Optimization, formulation, and characterization of multiflavonoids-loaded flavanosome by bulk or sequential technique

    Directory of Open Access Journals (Sweden)

    Karthivashan G

    2016-07-01

    Full Text Available Govindarajan Karthivashan,1 Mas Jaffri Masarudin,2 Aminu Umar Kura,1 Faridah Abas,3,4 Sharida Fakurazi1,5 1Laboratory of Vaccines and Immunotherapeutics, Institute of Bioscience, 2Department of Cell and Molecular Biology, Faculty of Biotechnology and Biomolecular Sciences, 3Department of Food Science, Faculty of Food Science and Technology, 4Laboratory of Natural Products, Institute of Bioscience, 5Department of Human Anatomy, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Selangor, Malaysia Abstract: This study involves adaptation of bulk or sequential technique to load multiple flavonoids in a single phytosome, which can be termed as “flavonosome”. Three widely established and therapeutically valuable flavonoids, such as quercetin (Q, kaempferol (K, and apigenin (A, were quantified in the ethyl acetate fraction of Moringa oleifera leaves extract and were commercially obtained and incorporated in a single flavonosome (QKA–phosphatidylcholine through four different methods of synthesis – bulk (M1 and serialized (M2 co-sonication and bulk (M3 and sequential (M4 co-loading. The study also established an optimal formulation method based on screening the synthesized flavonosomes with respect to their size, charge, polydispersity index, morphology, drug–carrier interaction, antioxidant potential through in vitro 1,1-diphenyl-2-picrylhydrazyl kinetics, and cytotoxicity evaluation against human hepatoma cell line (HepaRG. Furthermore, entrapment and loading efficiency of flavonoids in the optimal flavonosome have been identified. Among the four synthesis methods, sequential loading technique has been optimized as the best method for the synthesis of QKA–phosphatidylcholine flavonosome, which revealed an average diameter of 375.93±33.61 nm, with a zeta potential of -39.07±3.55 mV, and the entrapment efficiency was >98% for all the flavonoids, whereas the drug-loading capacity of Q, K, and A was 31.63%±0

  2. q-Space Upsampling Using x-q Space Regularization.

    Science.gov (United States)

    Chen, Geng; Dong, Bin; Zhang, Yong; Shen, Dinggang; Yap, Pew-Thian

    2017-09-01

    Acquisition time in diffusion MRI increases with the number of diffusion-weighted images that need to be acquired. Particularly in clinical settings, scan time is limited and only a sparse coverage of the vast q -space is possible. In this paper, we show how non-local self-similar information in the x - q space of diffusion MRI data can be harnessed for q -space upsampling. More specifically, we establish the relationships between signal measurements in x - q space using a patch matching mechanism that caters to unstructured data. We then encode these relationships in a graph and use it to regularize an inverse problem associated with recovering a high q -space resolution dataset from its low-resolution counterpart. Experimental results indicate that the high-resolution datasets reconstructed using the proposed method exhibit greater quality, both quantitatively and qualitatively, than those obtained using conventional methods, such as interpolation using spherical radial basis functions (SRBFs).

  3. Overcoming Learning Time And Space Constraints Through Technological Tool

    Directory of Open Access Journals (Sweden)

    Nafiseh Zarei

    2015-08-01

    Full Text Available Today the use of technological tools has become an evolution in language learning and language acquisition. Many instructors and lecturers believe that integrating Web-based learning tools into language courses allows pupils to become active learners during learning process. This study investigate how the Learning Management Blog (LMB overcomes the learning time and space constraints that contribute to students’ language learning and language acquisition processes. The participants were 30 ESL students at National University of Malaysia. A qualitative approach comprising an open-ended questionnaire and a semi-structured interview was used to collect data. The results of the study revealed that the students’ language learning and acquisition processes were enhanced. The students did not face any learning time and space limitations while being engaged in the learning process via the LMB. They learned and acquired knowledge using the language learning materials and forum at anytime and anywhere. Keywords: learning time, learning space, learning management blog

  4. Sequential low and medium frequency ultrasound assists biodegradation of wheat chaff by white rot fungal enzymes.

    Science.gov (United States)

    Oliver, Christine M; Mawson, Raymond; Melton, Laurence D; Dumsday, Geoff; Welch, Jessica; Sanguansri, Peerasak; Singh, Tanoj K; Augustin, Mary Ann

    2014-10-13

    The consequences of ultrasonic pre-treatment using low (40 kHz) and medium (270 kHz) frequency (40 kHz followed by 270 kHz) on the degradation of wheat chaff (8 g 100ml(-1) acetate buffer, pH 5) were evaluated. In addition, the effects of the ultrasonic pre-treatment on the degradation of the wheat chaff when subsequently exposed to enzyme extracts from two white rot fungi (Phanerochaete chrysosporium and Trametes sp.) were investigated. Pre-treatment by sequential low and medium frequency ultrasound had a disruptive effect on the lignocellulosic matrix. Analysis of the phenolic-derived volatiles after enzymatic hydrolysis showed that biodegradation with the enzyme extract obtained from P. chrysosporium was more pronounced compared to that of the Trametes sp. The efficacy of the ultrasonic pre-treatment was attributed to increased enzyme accessibility of the cellulose fibrils due to sonication-induced disruption of the plant surface structure, as shown by changes in the microstructure. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. C-quence: a tool for analyzing qualitative sequential data.

    Science.gov (United States)

    Duncan, Starkey; Collier, Nicholson T

    2002-02-01

    C-quence is a software application that matches sequential patterns of qualitative data specified by the user and calculates the rate of occurrence of these patterns in a data set. Although it was designed to facilitate analyses of face-to-face interaction, it is applicable to any data set involving categorical data and sequential information. C-quence queries are constructed using a graphical user interface. The program does not limit the complexity of the sequential patterns specified by the user.

  6. Automated data acquisition technology development:Automated modeling and control development

    Science.gov (United States)

    Romine, Peter L.

    1995-01-01

    This report documents the completion of, and improvements made to, the software developed for automated data acquisition and automated modeling and control development on the Texas Micro rackmounted PC's. This research was initiated because a need was identified by the Metal Processing Branch of NASA Marshall Space Flight Center for a mobile data acquisition and data analysis system, customized for welding measurement and calibration. Several hardware configurations were evaluated and a PC based system was chosen. The Welding Measurement System (WMS), is a dedicated instrument strickly for use of data acquisition and data analysis. In addition to the data acquisition functions described in this thesis, WMS also supports many functions associated with process control. The hardware and software requirements for an automated acquisition system for welding process parameters, welding equipment checkout, and welding process modeling were determined in 1992. From these recommendations, NASA purchased the necessary hardware and software. The new welding acquisition system is designed to collect welding parameter data and perform analysis to determine the voltage versus current arc-length relationship for VPPA welding. Once the results of this analysis are obtained, they can then be used to develop a RAIL function to control welding startup and shutdown without torch crashing.

  7. k-space sampling optimization for ultrashort TE imaging of cortical bone: Applications in radiation therapy planning and MR-based PET attenuation correction

    International Nuclear Information System (INIS)

    Hu, Lingzhi; Traughber, Melanie; Su, Kuan-Hao; Pereira, Gisele C.; Grover, Anu; Traughber, Bryan; Muzic, Raymond F. Jr.

    2014-01-01

    Purpose: The ultrashort echo-time (UTE) sequence is a promising MR pulse sequence for imaging cortical bone which is otherwise difficult to image using conventional MR sequences and also poses strong attenuation for photons in radiation therapy and PET imaging. The authors report here a systematic characterization of cortical bone signal decay and a scanning time optimization strategy for the UTE sequence through k-space undersampling, which can result in up to a 75% reduction in acquisition time. Using the undersampled UTE imaging sequence, the authors also attempted to quantitatively investigate the MR properties of cortical bone in healthy volunteers, thus demonstrating the feasibility of using such a technique for generating bone-enhanced images which can be used for radiation therapy planning and attenuation correction with PET/MR. Methods: An angularly undersampled, radially encoded UTE sequence was used for scanning the brains of healthy volunteers. Quantitative MR characterization of tissue properties, including water fraction and R2 ∗ = 1/T2 ∗ , was performed by analyzing the UTE images acquired at multiple echo times. The impact of different sampling rates was evaluated through systematic comparison of the MR image quality, bone-enhanced image quality, image noise, water fraction, and R2 ∗ of cortical bone. Results: A reduced angular sampling rate of the UTE trajectory achieves acquisition durations in proportion to the sampling rate and in as short as 25% of the time required for full sampling using a standard Cartesian acquisition, while preserving unique MR contrast within the skull at the cost of a minimal increase in noise level. The R2 ∗ of human skull was measured as 0.2–0.3 ms −1 depending on the specific region, which is more than ten times greater than the R2 ∗ of soft tissue. The water fraction in human skull was measured to be 60%–80%, which is significantly less than the >90% water fraction in brain. High-quality, bone

  8. 128 Channel PCI-based data acquisition system for MDSplus

    Energy Technology Data Exchange (ETDEWEB)

    Llobet, Xavier E-mail: xavier.llobet@epfl.ch; Duval, Basil P. E-mail: basil.duval@epfl.ch

    2002-06-01

    With the increasing demand for analogue channel acquisition on the TCV tokamak, a new PCI based acquisition has been specified, designed, built and installed into our MDSplus acquisition environment. The design criteria were to not only improve the cost/channel, as compared to our conventional hub based acquisition (CAMAC), but to provide some distributed processing power to avoid the associated acquisition server saturation, both in terms of CPU and network bandwidth. These units were initially intended to satisfy the requirements of general variable rate acquisition from a variety of sources, and many channel acquisition from modern multi-channel diagnostics. Hosted by a i386-Linux PC in a crate with four available PCI slots, each single-PCI slot 32-channel digitiser features sampling frequencies up to 200 kHz, and 64 MB of memory, providing 1 Msample of 16-bit data per channel. The local hard disk is used for immediate local storage of all the acquired data from the selected channels into a local MDSplus database. The host is then accessed as a MDS/IP server that provides, on demand, down-sampled and software filtered traces. The local hard disk capacity is used for medium to long-term storage and availability of the full data set with optional mirror technology to guard against hard disk failure. We have thus obtained a general solution for high resolution, multi-channel routine acquisition using the multi-platform MDSplus environment, in which different software and hardware architectures are intelligently linked across a standard TCP/IP network. The implementation presented here uses ONLY standard components of the MDSplus environment.

  9. 128 Channel PCI-based data acquisition system for MDSplus

    International Nuclear Information System (INIS)

    Llobet, Xavier; Duval, Basil P.

    2002-01-01

    With the increasing demand for analogue channel acquisition on the TCV tokamak, a new PCI based acquisition has been specified, designed, built and installed into our MDSplus acquisition environment. The design criteria were to not only improve the cost/channel, as compared to our conventional hub based acquisition (CAMAC), but to provide some distributed processing power to avoid the associated acquisition server saturation, both in terms of CPU and network bandwidth. These units were initially intended to satisfy the requirements of general variable rate acquisition from a variety of sources, and many channel acquisition from modern multi-channel diagnostics. Hosted by a i386-Linux PC in a crate with four available PCI slots, each single-PCI slot 32-channel digitiser features sampling frequencies up to 200 kHz, and 64 MB of memory, providing 1 Msample of 16-bit data per channel. The local hard disk is used for immediate local storage of all the acquired data from the selected channels into a local MDSplus database. The host is then accessed as a MDS/IP server that provides, on demand, down-sampled and software filtered traces. The local hard disk capacity is used for medium to long-term storage and availability of the full data set with optional mirror technology to guard against hard disk failure. We have thus obtained a general solution for high resolution, multi-channel routine acquisition using the multi-platform MDSplus environment, in which different software and hardware architectures are intelligently linked across a standard TCP/IP network. The implementation presented here uses ONLY standard components of the MDSplus environment

  10. Comparison of sequential vs same-day simultaneous collagen cross-linking and topography-guided PRK for treatment of keratoconus.

    Science.gov (United States)

    Kanellopoulos, Anastasios John

    2009-09-01

    The safety and efficacy of corneal collagen cross-linking (CXL) and topography-guided photorefractive keratectomy (PRK) using a different sequence and timing were evaluated in consecutive keratoconus cases. This study included a total of 325 eyes with keratoconus. Eyes were divided into two groups. The first group (n=127 eyes) underwent CXL with subsequent topography-guided PRK performed 6 months later (sequential group) and the second group (n=198 eyes) underwent CXL and PRK in a combined procedure on the same day (simultaneous group). Statistical differences were examined for pre- to postoperative changes in uncorrected (UCVA, logMAR) and best-spectacle-corrected visual acuity (BSCVA, logMAR), manifest refraction spherical equivalent (MRSE), keratometry (K), topography, central corneal thickness, endothelial cell count, corneal haze, and ectatic progression. Mean follow-up was 36+/-18 months (range: 24 to 68 months). At last follow-up in the sequential group, the mean UCVA improved from 0.9+/-0.3 logMAR to 0.49+/-0.25 logMAR, and mean BSCVA from 0.41+/-0.25 logMAR to 0.16+/-0.22 logMAR. Mean reduction in spherical equivalent refraction was 2.50+/-1.20 diopters (D), mean haze score was 1.2+/-0.5, and mean reduction in K was 2.75+/-1.30 D. In the simultaneous group, mean UCVA improved from 0.96+/-0.2 logMAR to 0.3+/-0.2 logMAR, and mean BSCVA from 0.39+/-0.3 logMAR to 0.11+/-0.16 logMAR. Mean reduction in spherical equivalent refraction was 3.20+/-1.40 D, mean haze score was 0.5+/-0.3, and mean reduction in K was 3.50+/-1.3 D. Endothelial cell count preoperatively and at last follow-up was unchanged (PPRK and CXL appears to be superior to sequential CXL with later PRK in the visual rehabilitation of progressing keratoconus. Copyright 2009, SLACK Incorporated.

  11. Advanced Biotelemetry Systems for Space Life Sciences: PH Telemetry

    Science.gov (United States)

    Hines, John W.; Somps, Chris; Ricks, Robert; Kim, Lynn; Connolly, John P. (Technical Monitor)

    1995-01-01

    The SENSORS 2000! (S2K!) program at NASA's Ames Research Center is currently developing a biotelemetry system for monitoring pH and temperature in unrestrained subjects. This activity is part of a broader scope effort to provide an Advanced Biotelemetry System (ABTS) for use in future space life sciences research. Many anticipated research endeavors will require biomedical and biochemical sensors and related instrumentation to make continuous inflight measurements in a variable-gravity environment. Since crew time is limited, automated data acquisition, data processing, data storage, and subject health monitoring are required. An automated biochemical and physiological data acquisition system based on non invasive or implantable biotelemetry technology will meet these requirements. The ABTS will ultimately acquire a variety of physiological measurands including temperature, biopotentials (e.g. ECG, EEG, EMG, EOG), blood pressure, flow and dimensions, as well as chemical and biological parameters including pH. Development activities are planned in evolutionary, leveraged steps. Near-term activities include 1) development of a dual channel pH/temperature telemetry system, and 2) development of a low bandwidth, 4-channel telemetry system, that measures temperature, heart rate, pressure, and pH. This abstract describes the pH/temperature telemeter.

  12. Top-down attention affects sequential regularity representation in the human visual system.

    Science.gov (United States)

    Kimura, Motohiro; Widmann, Andreas; Schröger, Erich

    2010-08-01

    Recent neuroscience studies using visual mismatch negativity (visual MMN), an event-related brain potential (ERP) index of memory-mismatch processes in the visual sensory system, have shown that although sequential regularities embedded in successive visual stimuli can be automatically represented in the visual sensory system, an existence of sequential regularity itself does not guarantee that the sequential regularity will be automatically represented. In the present study, we investigated the effects of top-down attention on sequential regularity representation in the visual sensory system. Our results showed that a sequential regularity (SSSSD) embedded in a modified oddball sequence where infrequent deviant (D) and frequent standard stimuli (S) differing in luminance were regularly presented (SSSSDSSSSDSSSSD...) was represented in the visual sensory system only when participants attended the sequential regularity in luminance, but not when participants ignored the stimuli or simply attended the dimension of luminance per se. This suggests that top-down attention affects sequential regularity representation in the visual sensory system and that top-down attention is a prerequisite for particular sequential regularities to be represented. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Mining compressing sequential problems

    NARCIS (Netherlands)

    Hoang, T.L.; Mörchen, F.; Fradkin, D.; Calders, T.G.K.

    2012-01-01

    Compression based pattern mining has been successfully applied to many data mining tasks. We propose an approach based on the minimum description length principle to extract sequential patterns that compress a database of sequences well. We show that mining compressing patterns is NP-Hard and

  14. Fast sequential Monte Carlo methods for counting and optimization

    CERN Document Server

    Rubinstein, Reuven Y; Vaisman, Radislav

    2013-01-01

    A comprehensive account of the theory and application of Monte Carlo methods Based on years of research in efficient Monte Carlo methods for estimation of rare-event probabilities, counting problems, and combinatorial optimization, Fast Sequential Monte Carlo Methods for Counting and Optimization is a complete illustration of fast sequential Monte Carlo techniques. The book provides an accessible overview of current work in the field of Monte Carlo methods, specifically sequential Monte Carlo techniques, for solving abstract counting and optimization problems. Written by authorities in the

  15. Computing sequential equilibria for two-player games

    DEFF Research Database (Denmark)

    Miltersen, Peter Bro

    2006-01-01

    Koller, Megiddo and von Stengel showed how to efficiently compute minimax strategies for two-player extensive-form zero-sum games with imperfect information but perfect recall using linear programming and avoiding conversion to normal form. Their algorithm has been used by AI researchers...... for constructing prescriptive strategies for concrete, often fairly large games. Koller and Pfeffer pointed out that the strategies obtained by the algorithm are not necessarily sequentially rational and that this deficiency is often problematic for the practical applications. We show how to remove this deficiency...... by modifying the linear programs constructed by Koller, Megiddo and von Stengel so that pairs of strategies forming a sequential equilibrium are computed. In particular, we show that a sequential equilibrium for a two-player zero-sum game with imperfect information but perfect recall can be found in polynomial...

  16. Computing Sequential Equilibria for Two-Player Games

    DEFF Research Database (Denmark)

    Miltersen, Peter Bro; Sørensen, Troels Bjerre

    2006-01-01

    Koller, Megiddo and von Stengel showed how to efficiently compute minimax strategies for two-player extensive-form zero-sum games with imperfect information but perfect recall using linear programming and avoiding conversion to normal form. Koller and Pfeffer pointed out that the strategies...... obtained by the algorithm are not necessarily sequentially rational and that this deficiency is often problematic for the practical applications. We show how to remove this deficiency by modifying the linear programs constructed by Koller, Megiddo and von Stengel so that pairs of strategies forming...... a sequential equilibrium are computed. In particular, we show that a sequential equilibrium for a two-player zero-sum game with imperfect information but perfect recall can be found in polynomial time. In addition, the equilibrium we find is normal-form perfect. Our technique generalizes to general-sum games...

  17. VME-Real-Time Data Acquisition for the Ultracryogenic Gravitational Antenna of the Third Generation

    Energy Technology Data Exchange (ETDEWEB)

    Mazzitelli, G. [Istituto Nazionale di Fisica Nucleare, Frascati (Italy). Lab. Nazionale di Frascati

    1996-05-01

    It is described a new design of the front-end electronics for the data acquisition of NAUTILUS, the first ultra cryogenic resonant gravitational wave detector, operating in the INFN National Laboratories of Frascati. The improved sensitivity of this kind of detector poses new requirements on the data acquisition, as more speed, amplitude and timing accuracy are needed. In this work it is discussed the result obtained with a new front-end configuration based on VME standard for a data acquisition rate of 5kHz (present rate 220 Hz). Is it also described the data acquisition system for the cosmic ray telescope assembled around NAUTILUS and the timing system of both the components.

  18. Information management system: A summary discussion. [for use in the space shuttle sortie, modular space station and TDR satellite

    Science.gov (United States)

    Sayers, R. S.

    1972-01-01

    An information management system is proposed for use in the space shuttle sortie, the modular space station, the tracking data relay satellite and associated ground support systems. Several different information management functions, including data acquisition, transfer, storage, processing, control and display are integrated in the system.

  19. Speed in Acquisitions

    DEFF Research Database (Denmark)

    Meglio, Olimpia; King, David R.; Risberg, Annette

    2017-01-01

    The advantage of speed is often invoked by academics and practitioners as an essential condition during post-acquisition integration, frequently without consideration of the impact earlier decisions have on acquisition speed. In this article, we examine the role speed plays in acquisitions across...... the acquisition process using research organized around characteristics that display complexity with respect to acquisition speed. We incorporate existing research with a process perspective of acquisitions in order to present trade-offs, and consider the influence of both stakeholders and the pre......-deal-completion context on acquisition speed, as well as the organization’s capabilities to facilitating that speed. Observed trade-offs suggest both that acquisition speed often requires longer planning time before an acquisition and that associated decisions require managerial judgement. A framework for improving...

  20. Moessbauer spectrometric data acquisition based on FPGA

    International Nuclear Information System (INIS)

    Zhang Yuan; Li Shimin; Chen Nan; Zhu Jingbo; Xia Yuanfu

    2008-01-01

    FPGA(Field Programmable Gate Array) is a programmable device with strong logical function and timing control ability. It is extremely potent in acquiring and processing timing signals. By replacing the traditional used SCM (Single-Chip Microcomputer) with FPGA, counting speed of Moessbauer spectrometric data acquisition can be improved markedly with significantly decreased size of the spectrometer. The counter, RAM and RS-232 communication of the module are developed on Altera Cyclone series chip EP1C6T144C8 with Quartus II. EP1C6T144C8 has 5980 logical units accompanied by 92160 bits of memory space. It is so powerful that all needs in data acquisition of the Moessbauer spectrometer can be perfectly satisfied while allowing modifications in functions and parameters. (authors)

  1. Sensitivity Analysis in Sequential Decision Models.

    Science.gov (United States)

    Chen, Qiushi; Ayer, Turgay; Chhatwal, Jagpreet

    2017-02-01

    Sequential decision problems are frequently encountered in medical decision making, which are commonly solved using Markov decision processes (MDPs). Modeling guidelines recommend conducting sensitivity analyses in decision-analytic models to assess the robustness of the model results against the uncertainty in model parameters. However, standard methods of conducting sensitivity analyses cannot be directly applied to sequential decision problems because this would require evaluating all possible decision sequences, typically in the order of trillions, which is not practically feasible. As a result, most MDP-based modeling studies do not examine confidence in their recommended policies. In this study, we provide an approach to estimate uncertainty and confidence in the results of sequential decision models. First, we provide a probabilistic univariate method to identify the most sensitive parameters in MDPs. Second, we present a probabilistic multivariate approach to estimate the overall confidence in the recommended optimal policy considering joint uncertainty in the model parameters. We provide a graphical representation, which we call a policy acceptability curve, to summarize the confidence in the optimal policy by incorporating stakeholders' willingness to accept the base case policy. For a cost-effectiveness analysis, we provide an approach to construct a cost-effectiveness acceptability frontier, which shows the most cost-effective policy as well as the confidence in that for a given willingness to pay threshold. We demonstrate our approach using a simple MDP case study. We developed a method to conduct sensitivity analysis in sequential decision models, which could increase the credibility of these models among stakeholders.

  2. The sequential structure of brain activation predicts skill.

    Science.gov (United States)

    Anderson, John R; Bothell, Daniel; Fincham, Jon M; Moon, Jungaa

    2016-01-29

    In an fMRI study, participants were trained to play a complex video game. They were scanned early and then again after substantial practice. While better players showed greater activation in one region (right dorsal striatum) their relative skill was better diagnosed by considering the sequential structure of whole brain activation. Using a cognitive model that played this game, we extracted a characterization of the mental states that are involved in playing a game and the statistical structure of the transitions among these states. There was a strong correspondence between this measure of sequential structure and the skill of different players. Using multi-voxel pattern analysis, it was possible to recognize, with relatively high accuracy, the cognitive states participants were in during particular scans. We used the sequential structure of these activation-recognized states to predict the skill of individual players. These findings indicate that important features about information-processing strategies can be identified from a model-based analysis of the sequential structure of brain activation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. A one-sided sequential test

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Lux, I. [Hungarian Academy of Sciences, Budapest (Hungary). Atomic Energy Research Inst.

    1996-04-16

    The applicability of the classical sequential probability ratio testing (SPRT) for early failure detection problems is limited by the fact that there is an extra time delay between the occurrence of the failure and its first recognition. Chien and Adams developed a method to minimize this time for the case when the problem can be formulated as testing the mean value of a Gaussian signal. In our paper we propose a procedure that can be applied for both mean and variance testing and that minimizes the time delay. The method is based on a special parametrization of the classical SPRT. The one-sided sequential tests (OSST) can reproduce the results of the Chien-Adams test when applied for mean values. (author).

  4. Development of data acquisition system for tracing fast flow using GPIB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications.

  5. Development of data acquisition system for tracing fast flow using GPIB

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications

  6. Mining Emerging Sequential Patterns for Activity Recognition in Body Sensor Networks

    DEFF Research Database (Denmark)

    Gu, Tao; Wang, Liang; Chen, Hanhua

    2010-01-01

    Body Sensor Networks oer many applications in healthcare, well-being and entertainment. One of the emerging applications is recognizing activities of daily living. In this paper, we introduce a novel knowledge pattern named Emerging Sequential Pattern (ESP)|a sequential pattern that discovers...... signicant class dierences|to recognize both simple (i.e., sequential) and complex (i.e., interleaved and concurrent) activities. Based on ESPs, we build our complex activity models directly upon the sequential model to recognize both activity types. We conduct comprehensive empirical studies to evaluate...

  7. Sequential use of technetium 99m MDP and gallium 67 citrate imaging in the evaluation of painful total hip replacement

    International Nuclear Information System (INIS)

    Horoszowski, H.; Ganel, A.; Kamhin, M.; Zaltman, S.; Farine, I.

    1980-01-01

    Fourteen patients with 20 total hip joint replacements were studied for 14 painful prosthetic hips. Clinical examination, plain film radiographs and 99 Tcsup(m)-methylene diphosphonate bone scans failed to differentiate between infection and mechanical loosening of a prosthesis. Sequential use of 99 Tcsup(m)-methylene diphosphonate and 67 Ga-citrate bone scans were performed in an attempt to discover underlying infectious process. Increased focal uptake of both radiopharmaceuticals over the same hip indicated an infectious process responsible for prosthetic loosening. There were no false positive gallium examinations. Sequential use of 99 Tcsup(m)-phosphate compounds and 67 Ga-citrate is recommended for differentiation between mechanical loosening of a prosthesis and loosening of a prosthesis secondary to an infectious process. (U.K.)

  8. Every k-separable Cech-complete space is subcompact

    NARCIS (Netherlands)

    van Mill, J.; Tkachuk, V.V.

    2015-01-01

    We establish that a Čech-complete space X must be subcompact if it has a dense subspace representable as the countable union of closed subcompact subspaces of X. In particular, if a Čech-complete space contains a dense σ-compact subspace then it is subcompact. This result is new even for separable

  9. Discrimination between sequential and simultaneous virtual channels with electrical hearing

    OpenAIRE

    Landsberger, David; Galvin, John J.

    2011-01-01

    In cochlear implants (CIs), simultaneous or sequential stimulation of adjacent electrodes can produce intermediate pitch percepts between those of the component electrodes. However, it is unclear whether simultaneous and sequential virtual channels (VCs) can be discriminated. In this study, CI users were asked to discriminate simultaneous and sequential VCs; discrimination was measured for monopolar (MP) and bipolar + 1 stimulation (BP + 1), i.e., relatively broad and focused stimulation mode...

  10. 102(ℎ/2π)k Large Area Atom Interferometers

    International Nuclear Information System (INIS)

    Chiow, Sheng-wey; Kovachy, Tim; Chien, Hui-Chun; Kasevich, Mark A.

    2011-01-01

    We demonstrate atom interferometers utilizing a novel beam splitter based on sequential multiphoton Bragg diffractions. With this sequential Bragg large momentum transfer (SB-LMT) beam splitter, we achieve high contrast atom interferometers with momentum splittings of up to 102 photon recoil momenta (102(ℎ/2π)k). To our knowledge, this is the highest momentum splitting achieved in any atom interferometer, advancing the state-of-the-art by an order of magnitude. We also demonstrate strong noise correlation between two simultaneous SB-LMT interferometers, which alleviates the need for ultralow noise lasers and ultrastable inertial environments in some future applications. Our method is intrinsically scalable and can be used to dramatically increase the sensitivity of atom interferometers in a wide range of applications, including inertial sensing, measuring the fine structure constant, and detecting gravitational waves.

  11. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. SPRINT: A Tool to Generate Concurrent Transaction-Level Models from Sequential Code

    Directory of Open Access Journals (Sweden)

    Richard Stahl

    2007-01-01

    Full Text Available A high-level concurrent model such as a SystemC transaction-level model can provide early feedback during the exploration of implementation alternatives for state-of-the-art signal processing applications like video codecs on a multiprocessor platform. However, the creation of such a model starting from sequential code is a time-consuming and error-prone task. It is typically done only once, if at all, for a given design. This lack of exploration of the design space often leads to a suboptimal implementation. To support our systematic C-based design flow, we have developed a tool to generate a concurrent SystemC transaction-level model for user-selected task boundaries. Using this tool, different parallelization alternatives have been evaluated during the design of an MPEG-4 simple profile encoder and an embedded zero-tree coder. Generation plus evaluation of an alternative was possible in less than six minutes. This is fast enough to allow extensive exploration of the design space.

  13. Visuo-spatial knowledge acquisition in individuals with Down syndrome: The role of descriptions and sketch maps.

    Science.gov (United States)

    Meneghetti, Chiara; Lanfranchi, Silvia; Carretti, Barbara; Toffalini, Enrico

    2017-04-01

    Few studies on individuals with Down syndrome (DS) have explored how they learn space. The present study examines space learning from verbal descriptions in individuals with DS, and explores the role of external cues (such as a sketch map). Twenty-eight individuals with DS and 28 matched typically-developing (TD) children listened to route or survey descriptions with or without seeing a corresponding sketch map (Description+Sketch Map [D+SM] and Description alone [D], respectively). After hearing each description, they performed tasks that involved recognizing, arranging sequentially, and locating landmarks. The results showed that individuals with DS performed less well in recognizing landmarks and arranging them sequentially. The D+SM condition produced general benefits in both groups' accuracy, though the improvement in locating landmarks was greater in the TD than in the DS group. In both groups, the D+SM condition prompted a better performance than the D condition when participants arranged landmarks sequentially after hearing a description from a route perspective, but not from a survey perspective. Overall, our results show that individuals with DS benefited when a spatial description was associated with a corresponding sketch map, albeit to a lesser degree than TD children. The findings are discussed in the light of the literature on DS and on spatial cognition in the TD domain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Hybrid Computerized Adaptive Testing: From Group Sequential Design to Fully Sequential Design

    Science.gov (United States)

    Wang, Shiyu; Lin, Haiyan; Chang, Hua-Hua; Douglas, Jeff

    2016-01-01

    Computerized adaptive testing (CAT) and multistage testing (MST) have become two of the most popular modes in large-scale computer-based sequential testing. Though most designs of CAT and MST exhibit strength and weakness in recent large-scale implementations, there is no simple answer to the question of which design is better because different…

  15. Sequential dependencies in magnitude scaling of loudness

    DEFF Research Database (Denmark)

    Joshi, Suyash Narendra; Jesteadt, Walt

    2013-01-01

    Ten normally hearing listeners used a programmable sone-potentiometer knob to adjust the level of a 1000-Hz sinusoid to match the loudness of numbers presented to them in a magnitude production task. Three different power-law exponents (0.15, 0.30, and 0.60) and a log-law with equal steps in d......B were used to program the sone-potentiometer. The knob settings systematically influenced the form of the loudness function. Time series analysis was used to assess the sequential dependencies in the data, which increased with increasing exponent and were greatest for the log-law. It would be possible......, therefore, to choose knob properties that minimized these dependencies. When the sequential dependencies were removed from the data, the slope of the loudness functions did not change, but the variability decreased. Sequential dependencies were only present when the level of the tone on the previous trial...

  16. Visual short-term memory for sequential arrays.

    Science.gov (United States)

    Kumar, Arjun; Jiang, Yuhong

    2005-04-01

    The capacity of visual short-term memory (VSTM) for a single visual display has been investigated in past research, but VSTM for multiple sequential arrays has been explored only recently. In this study, we investigate the capacity of VSTM across two sequential arrays separated by a variable stimulus onset asynchrony (SOA). VSTM for spatial locations (Experiment 1), colors (Experiments 2-4), orientations (Experiments 3 and 4), and conjunction of color and orientation (Experiment 4) were tested, with the SOA across the two sequential arrays varying from 100 to 1,500 msec. We find that VSTM for the trailing array is much better than VSTM for the leading array, but when averaged across the two arrays VSTM has a constant capacity independent of the SOA. We suggest that multiple displays compete for retention in VSTM and that separating information into two temporally discrete groups does not enhance the overall capacity of VSTM.

  17. Space shuttle main engine vibration data base

    Science.gov (United States)

    Lewallen, Pat

    1986-01-01

    The Space Shuttle Main Engine Vibration Data Base is described. Included is a detailed description of the data base components, the data acquisition process, the more sophisticated software routines, and the future data acquisition methods. Several figures and plots are provided to illustrate the various output formats accessible to the user. The numerous vibration data recall and analysis capabilities available through automated data base techniques are revealed.

  18. The target-to-foils shift in simultaneous and sequential lineups.

    Science.gov (United States)

    Clark, Steven E; Davey, Sherrie L

    2005-04-01

    A theoretical cornerstone in eyewitness identification research is the proposition that witnesses, in making decisions from standard simultaneous lineups, make relative judgments. The present research considers two sources of support for this proposal. An experiment by G. L. Wells (1993) showed that if the target is removed from a lineup, witnesses shift their responses to pick foils, rather than rejecting the lineups, a result we will term a target-to-foils shift. Additional empirical support is provided by results from sequential lineups which typically show higher accuracy than simultaneous lineups, presumably because of a decrease in the use of relative judgments in making identification decisions. The combination of these two lines of research suggests that the target-to-foils shift should be reduced in sequential lineups relative to simultaneous lineups. Results of two experiments showed an overall advantage for sequential lineups, but also showed a target-to-foils shift equal in size for simultaneous and sequential lineups. Additional analyses indicated that the target-to-foils shift in sequential lineups was moderated in part by an order effect and was produced with (Experiment 2) or without (Experiment 1) a shift in decision criterion. This complex pattern of results suggests that more work is needed to understand the processes which underlie decisions in simultaneous and sequential lineups.

  19. K3 projective models in scrolls

    CERN Document Server

    Johnsen, Trygve

    2004-01-01

    The exposition studies projective models of K3 surfaces whose hyperplane sections are non-Clifford general curves. These models are contained in rational normal scrolls. The exposition supplements standard descriptions of models of general K3 surfaces in projective spaces of low dimension, and leads to a classification of K3 surfaces in projective spaces of dimension at most 10. The authors bring further the ideas in Saint-Donat's classical article from 1974, lifting results from canonical curves to K3 surfaces and incorporating much of the Brill-Noether theory of curves and theory of syzygies developed in the mean time.

  20. Approximating Model Equivalence in Interactive Dynamic Influence Diagrams Using Top K Policy Paths

    DEFF Research Database (Denmark)

    Zeng, Y.; Chen, Y.; Doshi, Prashant

    2011-01-01

    Interactive dynamic influence diagrams (I-DIDs) are graphical models for sequential decision making in uncertain settings shared by other agents. Algorithms for solving I-DIDs face the challenge of an exponentially growing space of behavioral models ascribed to other agents over time. Previous ap...

  1. Comparative study of lesions created by high-intensity focused ultrasound using sequential discrete and continuous scanning strategies.

    Science.gov (United States)

    Fan, Tingbo; Liu, Zhenbo; Zhang, Dong; Tang, Mengxing

    2013-03-01

    Lesion formation and temperature distribution induced by high-intensity focused ultrasound (HIFU) were investigated both numerically and experimentally via two energy-delivering strategies, i.e., sequential discrete and continuous scanning modes. Simulations were presented based on the combination of Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation and bioheat equation. Measurements were performed on tissue-mimicking phantoms sonicated by a 1.12-MHz single-element focused transducer working at an acoustic power of 75 W. Both the simulated and experimental results show that, in the sequential discrete mode, obvious saw-tooth-like contours could be observed for the peak temperature distribution and the lesion boundaries, with the increasing interval space between two adjacent exposure points. In the continuous scanning mode, more uniform peak temperature distributions and lesion boundaries would be produced, and the peak temperature values would decrease significantly with the increasing scanning speed. In addition, compared to the sequential discrete mode, the continuous scanning mode could achieve higher treatment efficiency (lesion area generated per second) with a lower peak temperature. The present studies suggest that the peak temperature and tissue lesion resulting from the HIFU exposure could be controlled by adjusting the transducer scanning speed, which is important for improving the HIFU treatment efficiency.

  2. Dynamics-based sequential memory: Winnerless competition of patterns

    International Nuclear Information System (INIS)

    Seliger, Philip; Tsimring, Lev S.; Rabinovich, Mikhail I.

    2003-01-01

    We introduce a biologically motivated dynamical principle of sequential memory which is based on winnerless competition (WLC) of event images. This mechanism is implemented in a two-layer neural model of sequential spatial memory. We present the learning dynamics which leads to the formation of a WLC network. After learning, the system is capable of associative retrieval of prerecorded sequences of patterns

  3. Sequential, progressive, equal-power, reflective beam-splitter arrays

    Science.gov (United States)

    Manhart, Paul K.

    2017-11-01

    The equations to calculate equal-power reflectivity of a sequential series of beam splitters is presented. Non-sequential optical design examples are offered for uniform illumination using diode lasers. Objects created using Boolean operators and Swept Surfaces can create objects capable of reflecting light into predefined elevation and azimuth angles. Analysis of the illumination patterns for the array are also presented.

  4. Basal ganglia and cortical networks for sequential ordering and rhythm of complex movements

    Directory of Open Access Journals (Sweden)

    Jeffery G. Bednark

    2015-07-01

    Full Text Available Voluntary actions require the concurrent engagement and coordinated control of complex temporal (e.g. rhythm and ordinal motor processes. Using high-resolution functional magnetic resonance imaging (fMRI and multi-voxel pattern analysis (MVPA, we sought to determine the degree to which these complex motor processes are dissociable in basal ganglia and cortical networks. We employed three different finger-tapping tasks that differed in the demand on the sequential temporal rhythm or sequential ordering of submovements. Our results demonstrate that sequential rhythm and sequential order tasks were partially dissociable based on activation differences. The sequential rhythm task activated a widespread network centered around the SMA and basal-ganglia regions including the dorsomedial putamen and caudate nucleus, while the sequential order task preferentially activated a fronto-parietal network. There was also extensive overlap between sequential rhythm and sequential order tasks, with both tasks commonly activating bilateral premotor, supplementary motor, and superior/inferior parietal cortical regions, as well as regions of the caudate/putamen of the basal ganglia and the ventro-lateral thalamus. Importantly, within the cortical regions that were active for both complex movements, MVPA could accurately classify different patterns of activation for the sequential rhythm and sequential order tasks. In the basal ganglia, however, overlapping activation for the sequential rhythm and sequential order tasks, which was found in classic motor circuits of the putamen and ventro-lateral thalamus, could not be accurately differentiated by MVPA. Overall, our results highlight the convergent architecture of the motor system, where complex motor information that is spatially distributed in the cortex converges into a more compact representation in the basal ganglia.

  5. The sequential price of anarchy for atomic congestion games

    NARCIS (Netherlands)

    de Jong, Jasper; Uetz, Marc Jochen; Liu, Tie-Yan; Qi, Qi; Ye, Yinyu

    2014-01-01

    In situations without central coordination, the price of anarchy relates the quality of any Nash equilibrium to the quality of a global optimum. Instead of assuming that all players choose their actions simultaneously, we consider games where players choose their actions sequentially. The sequential

  6. Embedded multi-channel data acquisition system on FPGA for Aditya Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Rajpal, Rachana, E-mail: rachana@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Mandaliya, Hitesh, E-mail: hitesh@ipr.res.in [ITER, Cadarache (France); Patel, Jignesh, E-mail: jjp@ipr.res.in [ITER, Cadarache (France); Kumari, Praveena, E-mail: praveena@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Gautam, Pramila, E-mail: pramila@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Raulji, Vismaysinh, E-mail: vismay@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Edappala, Praveenlal, E-mail: praveen@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Pujara, H.D, E-mail: pujara@ipr.res [Institute for Plasma Research, Gandhinagar, Gujarat (India); Jha, R., E-mail: jha@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India)

    2016-11-15

    Highlights: • 64 channel data acquisition, interface to PC/104 bus, using single board computer. • Integration of all components in single hardware to make it standalone and portable. • Development of application software in Qt on Linux platform for better performance and low cost compared to Windows. • Explored and utilized FPGA resources for hardware interfacing. - Abstract: The 64 channel data acquisition board is designed to meet the future demand of acquisition channels for plasma diagnostics. The inherent features of the board are 16 bit resolution, programmable sampling rate upto 200 kS/s/ch and simultaneous acquisition. To make system embedded and compact, 8 Analog Inputs ADC chip, 4M × 16 bit RAM memory, Field Programmable Gate Arrays, PC/104 platform and single board computer are used. High speed timing control signals for all ADCs and RAMs are generated by FPGA. The system is standalone, portable and interface through Ethernet. The acquisition application is developed in Qt. on Linux platform, in SBC. Due to ethernet connectivity and onboard processing, system can be integrated into Aditya and SST-1 data acquisition system. The performance of hardware is tested on Linux and Windows Embedded OS. The paper describes design, hardware and software architecture, implementation and results of 64 channel DAQ system.

  7. Embedded multi-channel data acquisition system on FPGA for Aditya Tokamak

    International Nuclear Information System (INIS)

    Rajpal, Rachana; Mandaliya, Hitesh; Patel, Jignesh; Kumari, Praveena; Gautam, Pramila; Raulji, Vismaysinh; Edappala, Praveenlal; Pujara, H.D; Jha, R.

    2016-01-01

    Highlights: • 64 channel data acquisition, interface to PC/104 bus, using single board computer. • Integration of all components in single hardware to make it standalone and portable. • Development of application software in Qt on Linux platform for better performance and low cost compared to Windows. • Explored and utilized FPGA resources for hardware interfacing. - Abstract: The 64 channel data acquisition board is designed to meet the future demand of acquisition channels for plasma diagnostics. The inherent features of the board are 16 bit resolution, programmable sampling rate upto 200 kS/s/ch and simultaneous acquisition. To make system embedded and compact, 8 Analog Inputs ADC chip, 4M × 16 bit RAM memory, Field Programmable Gate Arrays, PC/104 platform and single board computer are used. High speed timing control signals for all ADCs and RAMs are generated by FPGA. The system is standalone, portable and interface through Ethernet. The acquisition application is developed in Qt. on Linux platform, in SBC. Due to ethernet connectivity and onboard processing, system can be integrated into Aditya and SST-1 data acquisition system. The performance of hardware is tested on Linux and Windows Embedded OS. The paper describes design, hardware and software architecture, implementation and results of 64 channel DAQ system.

  8. Native Frames: Disentangling Sequential from Concerted Three-Body Fragmentation

    Science.gov (United States)

    Rajput, Jyoti; Severt, T.; Berry, Ben; Jochim, Bethany; Feizollah, Peyman; Kaderiya, Balram; Zohrabi, M.; Ablikim, U.; Ziaee, Farzaneh; Raju P., Kanaka; Rolles, D.; Rudenko, A.; Carnes, K. D.; Esry, B. D.; Ben-Itzhak, I.

    2018-03-01

    A key question concerning the three-body fragmentation of polyatomic molecules is the distinction of sequential and concerted mechanisms, i.e., the stepwise or simultaneous cleavage of bonds. Using laser-driven fragmentation of OCS into O++C++S+ and employing coincidence momentum imaging, we demonstrate a novel method that enables the clear separation of sequential and concerted breakup. The separation is accomplished by analyzing the three-body fragmentation in the native frame associated with each step and taking advantage of the rotation of the intermediate molecular fragment, CO2 + or CS2 + , before its unimolecular dissociation. This native-frame method works for any projectile (electrons, ions, or photons), provides details on each step of the sequential breakup, and enables the retrieval of the relevant spectra for sequential and concerted breakup separately. Specifically, this allows the determination of the branching ratio of all these processes in OCS3 + breakup. Moreover, we find that the first step of sequential breakup is tightly aligned along the laser polarization and identify the likely electronic states of the intermediate dication that undergo unimolecular dissociation in the second step. Finally, the separated concerted breakup spectra show clearly that the central carbon atom is preferentially ejected perpendicular to the laser field.

  9. The Defense Systems Acquisition and Review Council

    Science.gov (United States)

    1976-09-15

    34 or budget subimittal and explained. f. w.hen an OSD-generated PPES document, such as tK2 Issue Paper or PPJ, offers an alternative to the 9CP/ )SARC...cost objectives, and operating constraints. A mission need may result from a deficiency in existing agency capabilities or the decision to establish new...missions, capabilities; deficiencies , and needs and objectives related to acquisition programs, in consonance with Section 601(i) of the Congressional

  10. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  11. A Fast Exact k-Nearest Neighbors Algorithm for High Dimensional Search Using k-Means Clustering and Triangle Inequality.

    Science.gov (United States)

    Wang, Xueyi

    2012-02-08

    The k-nearest neighbors (k-NN) algorithm is a widely used machine learning method that finds nearest neighbors of a test object in a feature space. We present a new exact k-NN algorithm called kMkNN (k-Means for k-Nearest Neighbors) that uses the k-means clustering and the triangle inequality to accelerate the searching for nearest neighbors in a high dimensional space. The kMkNN algorithm has two stages. In the buildup stage, instead of using complex tree structures such as metric trees, kd-trees, or ball-tree, kMkNN uses a simple k-means clustering method to preprocess the training dataset. In the searching stage, given a query object, kMkNN finds nearest training objects starting from the nearest cluster to the query object and uses the triangle inequality to reduce the distance calculations. Experiments show that the performance of kMkNN is surprisingly good compared to the traditional k-NN algorithm and tree-based k-NN algorithms such as kd-trees and ball-trees. On a collection of 20 datasets with up to 10(6) records and 10(4) dimensions, kMkNN shows a 2-to 80-fold reduction of distance calculations and a 2- to 60-fold speedup over the traditional k-NN algorithm for 16 datasets. Furthermore, kMkNN performs significant better than a kd-tree based k-NN algorithm for all datasets and performs better than a ball-tree based k-NN algorithm for most datasets. The results show that kMkNN is effective for searching nearest neighbors in high dimensional spaces.

  12. Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography

    International Nuclear Information System (INIS)

    Blanke, Philipp; Baumann, Tobias; Langer, Mathias; Pache, Gregor

    2010-01-01

    To prospectively investigate the feasibility, image quality and radiation dose estimates for computed tomography angiography (CTA) of the pulmonary veins and left atrium using prospective electrocardiography (ECG)-triggered sequential dual-source (DS) data acquisition at end-systole in patients with paroxysmal atrial fibrillation undergoing radiofrequency ablation. Thirty-five patients (mean age 66.2 ± 12.6 years) with paroxysmal atrial fibrillation underwent prospective ECG-triggered sequential DS-CTA with tube current (250 mAs/rotation) centred 250 ms past the R-peak. Tube voltage was adjusted to the BMI ( 2 : 100 kV, >25 kg/m 2 : 120 kV). Presence of motion or stair-step artefacts was assessed. Effective radiation dose was calculated from the dose-length product. All data sets could be integrated into the electroanatomical mapping system. Twenty-two patients (63%) were in sinus rhythm (mean heart rate 69.2 ± 11.1 bpm, variability 1.0 ± 1.7 bpm) and 13 (37%) showed an ECG pattern of atrial fibrillation (mean heart rate 84.8 ± 16.6 bpm, variability 17.9 ± 7.5 bpm). Minor step artefacts were observed in three patients (23%) with atrial fibrillation. Mean estimated effective dose was 1.1 ± 0.3 and 3.0 ± 0.5 mSv for 100 and 120 kV respectively. Imaging of pulmonary vein anatomy is feasible using prospective ECG-triggered sequential data acquisition at end-systole regardless of heart rate or rhythm at the benefit of low radiation dose. (orig.)

  13. Campbell and moment measures for finite sequential spatial processes

    NARCIS (Netherlands)

    M.N.M. van Lieshout (Marie-Colette)

    2006-01-01

    textabstractWe define moment and Campbell measures for sequential spatial processes, prove a Campbell-Mecke theorem, and relate the results to their counterparts in the theory of point processes. In particular, we show that any finite sequential spatial process model can be derived as the vector

  14. Information management system breadboard data acquisition and control system.

    Science.gov (United States)

    Mallary, W. E.

    1972-01-01

    Description of a breadboard configuration of an advanced information management system based on requirements for high data rates and local and centralized computation for subsystems and experiments to be housed on a space station. The system is to contain a 10-megabit-per-second digital data bus, remote terminals with preprocessor capabilities, and a central multiprocessor. A concept definition is presented for the data acquisition and control system breadboard, and a detailed account is given of the operation of the bus control unit, the bus itself, and the remote acquisition and control unit. The data bus control unit is capable of operating under control of both its own test panel and the test processor. In either mode it is capable of both single- and multiple-message operation in that it can accept a block of data requests or update commands for transmission to the remote acquisition and control unit, which in turn is capable of three levels of data-handling complexity.

  15. Sequential Dependencies in Driving

    Science.gov (United States)

    Doshi, Anup; Tran, Cuong; Wilder, Matthew H.; Mozer, Michael C.; Trivedi, Mohan M.

    2012-01-01

    The effect of recent experience on current behavior has been studied extensively in simple laboratory tasks. We explore the nature of sequential effects in the more naturalistic setting of automobile driving. Driving is a safety-critical task in which delayed response times may have severe consequences. Using a realistic driving simulator, we find…

  16. Embedding a State Space Model Into a Markov Decision Process

    DEFF Research Database (Denmark)

    Nielsen, Lars Relund; Jørgensen, Erik; Højsgaard, Søren

    2011-01-01

    In agriculture Markov decision processes (MDPs) with finite state and action space are often used to model sequential decision making over time. For instance, states in the process represent possible levels of traits of the animal and transition probabilities are based on biological models...

  17. Effects of cueing and collaboration on the Acquisition of Complex Legal Skills

    NARCIS (Netherlands)

    Hummel, Hans; Paas, Fred; Koper, Rob

    2005-01-01

    Hummel, H. G. K., Paas, F., & Koper, R. (2006). Effects of cueing and collaboration on the Acquisition of Complex Legal Skills. British Journal of Educational Psychology, 76(3), 613-632. [Also availabe at http://hdl.handle.net/1820/1646

  18. Effects of cueing and collaboration on the Acquisition of Complex Legal Skills

    NARCIS (Netherlands)

    Hummel, Hans; Paas, Fred; Koper, Rob

    2008-01-01

    Hummel, H. G. K., Paas, F., & Koper, R. (2006). Effects of cueing and collaboration on the Acquisition of Complex Legal Skills. British Journal of Educational Psychology, 76(3), 613-632. [Also availabe at http://hdl.handle.net/1820/482

  19. Quantized fields and operators on a partial inner product space

    International Nuclear Information System (INIS)

    Shabani, J.

    1985-11-01

    We investigate the connection between the space OpV of all operators on a partial inner product space V and the weak sequential completion of the * algebra L + (Vsup(no.)) of all operators X such that Vsup(no.) is contained in D(X) intersection D(X*) and both X and its adjoint X* leave Vsup(no.) invariant. This connection gives a mathematical description of quantized fields in terms of elements of OpV. (author)

  20. Dual joint space arthrography in temporomandibular joint disorders: Comparison with single inferior joint space arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyung Sik; Chang, Duk Soo; Lee, Kyung Soo; Kim, Woo Sun; Sung, Jung Ho; Jun, Young Hwan [Capital Armed Forces General Hospital, Seoul (Korea, Republic of)

    1989-02-15

    The temporomandibular joint(TMJ) is really a complex of two synovial space separated by fibrocartilaginous disc. Single inferior joint space arthrography is commonly performed for evaluation of TMJ disorders, which is known to be superior in demonstrating joint dynamics. But it reveals only the inferior surface of the disc. Therefore, dual space arthrography is superior to demonstrate the soft tissue anatomic feature of the joint such as disc position and shape. Authors performed 83 TMJ arthrograms in TMJ problems. Initially, the inferior joint space was done and then the superior space was sequentially contrasted. The follow results were noted: 1. In all cases, dual space arthrography revealed accurate disc shape and positions. 2. Concordant findings between the two techniques: 68 cases (82%). Discordance between the two techniques: 15 cases (18%) 3. Possible causes of discordance between inferior and dual space arthrography. a) Normal varians of anterior recess: 3 cases b) Posterior disc displacement: 4 cases c) Influence of the patient's head position change :4 cases d) False perforation: 2 cases e) Reduction change: 2 cases 4. In 5 cases with anterior displacement, dual space arthrography gave additional findings such as adhesion within the superior space, which could not be evaluated by single inferior space.

  1. The GRIFFIN data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Garnsworthy, A.B., E-mail: garns@triumf.ca [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Pearson, C.J.; Bishop, D.; Shaw, B.; Smith, J.K.; Bowry, M. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Bildstein, V. [Department of Physics, University of Guelph, 50 Stone Rd E, Guelph, ON, Canada N1G 2W1 (Canada); Hackman, G. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Garrett, P.E. [Department of Physics, University of Guelph, 50 Stone Rd E, Guelph, ON, Canada N1G 2W1 (Canada); Linn, Y. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Martin, J.-P. [Department of Physics, Université de Montréal, 2900 Boulevard Edouard-Montpetit, Montréal, QC, Canada H3T 1J4 (Canada); Mills, W.J. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Svensson, C.E. [Department of Physics, University of Guelph, 50 Stone Rd E, Guelph, ON, Canada N1G 2W1 (Canada)

    2017-05-01

    Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. This article describes the details of the custom designed GRIFFIN digital data acquisition system. The features of the system that will enable high-precision half-life and branching ratio measurements with levels of uncertainty better than 0.05% are described. The system has demonstrated the ability to effectively collect signals from High-purity germanium crystals at counting rates up to 50 kHz while maintaining good energy resolution, detection efficiency and spectral quality.

  2. Smart acquisition EELS

    International Nuclear Information System (INIS)

    Sader, Kasim; Schaffer, Bernhard; Vaughan, Gareth; Brydson, Rik; Brown, Andy; Bleloch, Andrew

    2010-01-01

    We have developed a novel acquisition methodology for the recording of electron energy loss spectra (EELS) using a scanning transmission electron microscope (STEM): 'Smart Acquisition'. Smart Acquisition allows the independent control of probe scanning procedures and the simultaneous acquisition of analytical signals such as EELS. The original motivation for this work arose from the need to control the electron dose experienced by beam-sensitive specimens whilst maintaining a sufficiently high signal-to-noise ratio in the EEL signal for the extraction of useful analytical information (such as energy loss near edge spectral features) from relatively undamaged areas. We have developed a flexible acquisition framework which separates beam position data input, beam positioning, and EELS acquisition. In this paper we demonstrate the effectiveness of this technique on beam-sensitive thin films of amorphous aluminium trifluoride. Smart Acquisition has been used to expose lines to the electron beam, followed by analysis of the structures created by line-integrating EELS acquisitions, and the results are compared to those derived from a standard EELS linescan. High angle annular dark-field images show clear reductions in damage for the Smart Acquisition areas compared to the conventional linescan, and the Smart Acquisition low loss EEL spectra are more representative of the undamaged material than those derived using a conventional linescan. Atomically resolved EELS of all four elements of CaNdTiO show the high resolution capabilities of Smart Acquisition.

  3. Smart acquisition EELS

    Energy Technology Data Exchange (ETDEWEB)

    Sader, Kasim, E-mail: k.sader@leeds.ac.uk [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Schaffer, Bernhard [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Department of Physics and Astronomy, University of Glasgow (United Kingdom); Vaughan, Gareth [Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Brydson, Rik [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Brown, Andy [Institute for Materials Research, University of Leeds, LS2 9JT (United Kingdom); Bleloch, Andrew [SuperSTEM, J block, Daresbury Laboratory, Warrington, Cheshire, WA4 4AD (United Kingdom); Department of Engineering, University of Liverpool, Liverpool (United Kingdom)

    2010-07-15

    We have developed a novel acquisition methodology for the recording of electron energy loss spectra (EELS) using a scanning transmission electron microscope (STEM): 'Smart Acquisition'. Smart Acquisition allows the independent control of probe scanning procedures and the simultaneous acquisition of analytical signals such as EELS. The original motivation for this work arose from the need to control the electron dose experienced by beam-sensitive specimens whilst maintaining a sufficiently high signal-to-noise ratio in the EEL signal for the extraction of useful analytical information (such as energy loss near edge spectral features) from relatively undamaged areas. We have developed a flexible acquisition framework which separates beam position data input, beam positioning, and EELS acquisition. In this paper we demonstrate the effectiveness of this technique on beam-sensitive thin films of amorphous aluminium trifluoride. Smart Acquisition has been used to expose lines to the electron beam, followed by analysis of the structures created by line-integrating EELS acquisitions, and the results are compared to those derived from a standard EELS linescan. High angle annular dark-field images show clear reductions in damage for the Smart Acquisition areas compared to the conventional linescan, and the Smart Acquisition low loss EEL spectra are more representative of the undamaged material than those derived using a conventional linescan. Atomically resolved EELS of all four elements of CaNdTiO show the high resolution capabilities of Smart Acquisition.

  4. Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging.

    Science.gov (United States)

    Zhou, Ruixi; Huang, Wei; Yang, Yang; Chen, Xiao; Weller, Daniel S; Kramer, Christopher M; Kozerke, Sebastian; Salerno, Michael

    2018-02-01

    Cardiovascular magnetic resonance (CMR) stress perfusion imaging provides important diagnostic and prognostic information in coronary artery disease (CAD). Current clinical sequences have limited temporal and/or spatial resolution, and incomplete heart coverage. Techniques such as k-t principal component analysis (PCA) or k-t sparcity and low rank structure (SLR), which rely on the high degree of spatiotemporal correlation in first-pass perfusion data, can significantly accelerate image acquisition mitigating these problems. However, in the presence of respiratory motion, these techniques can suffer from significant degradation of image quality. A number of techniques based on non-rigid registration have been developed. However, to first approximation, breathing motion predominantly results in rigid motion of the heart. To this end, a simple robust motion correction strategy is proposed for k-t accelerated and compressed sensing (CS) perfusion imaging. A simple respiratory motion compensation (MC) strategy for k-t accelerated and compressed-sensing CMR perfusion imaging to selectively correct respiratory motion of the heart was implemented based on linear k-space phase shifts derived from rigid motion registration of a region-of-interest (ROI) encompassing the heart. A variable density Poisson disk acquisition strategy was used to minimize coherent aliasing in the presence of respiratory motion, and images were reconstructed using k-t PCA and k-t SLR with or without motion correction. The strategy was evaluated in a CMR-extended cardiac torso digital (XCAT) phantom and in prospectively acquired first-pass perfusion studies in 12 subjects undergoing clinically ordered CMR studies. Phantom studies were assessed using the Structural Similarity Index (SSIM) and Root Mean Square Error (RMSE). In patient studies, image quality was scored in a blinded fashion by two experienced cardiologists. In the phantom experiments, images reconstructed with the MC strategy had higher

  5. Large-scale sequential quadratic programming algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Eldersveld, S.K.

    1992-09-01

    The problem addressed is the general nonlinear programming problem: finding a local minimizer for a nonlinear function subject to a mixture of nonlinear equality and inequality constraints. The methods studied are in the class of sequential quadratic programming (SQP) algorithms, which have previously proved successful for problems of moderate size. Our goal is to devise an SQP algorithm that is applicable to large-scale optimization problems, using sparse data structures and storing less curvature information but maintaining the property of superlinear convergence. The main features are: 1. The use of a quasi-Newton approximation to the reduced Hessian of the Lagrangian function. Only an estimate of the reduced Hessian matrix is required by our algorithm. The impact of not having available the full Hessian approximation is studied and alternative estimates are constructed. 2. The use of a transformation matrix Q. This allows the QP gradient to be computed easily when only the reduced Hessian approximation is maintained. 3. The use of a reduced-gradient form of the basis for the null space of the working set. This choice of basis is more practical than an orthogonal null-space basis for large-scale problems. The continuity condition for this choice is proven. 4. The use of incomplete solutions of quadratic programming subproblems. Certain iterates generated by an active-set method for the QP subproblem are used in place of the QP minimizer to define the search direction for the nonlinear problem. An implementation of the new algorithm has been obtained by modifying the code MINOS. Results and comparisons with MINOS and NPSOL are given for the new algorithm on a set of 92 test problems.

  6. A fast data acquisition system for PHA and MCS measurements

    International Nuclear Information System (INIS)

    Eijk, P.J.A. van; Keyser, C.J.; Rigterink, B.J.; Hasper, H.

    1985-01-01

    A microprocessor controlled data acquisition system for pulse height analysis and multichannel scaling is described. A 4K x 24 bit static memory is used to obtain a fast data acquisition rate. The system can store 12 bit ADC or TDC data within 150 ns. Operating commands can be entered via a small keyboard or by a RS-232-C interface. An oscilloscope is used to display a spectrum. The display of a spectrum or the transmission of spectrum data to an external computer causes only a short interruption of a measurement in progress and is accomplished by using a DMA circuit. The program is written in Modular Pascal and is divided into 15 modules. These implement 9 parallel processes which are synchronized by using semaphores. Hardware interrupts from the data acquisition, DMA, keyboard and RS-232-C circuits are used to signal these processes. (orig.)

  7. 30-kW SEP Spacecraft as Secondary Payloads for Low-Cost Deep Space Science Missions

    Science.gov (United States)

    Brophy, John R.; Larson, Tim

    2013-01-01

    The Solar Array System contracts awarded by NASA's Space Technology Mission Directorate are developing solar arrays in the 30 kW to 50 kW power range (beginning of life at 1 AU) that have significantly higher specific powers (W/kg) and much smaller stowed volumes than conventional rigid-panel arrays. The successful development of these solar array technologies has the potential to enable new types of solar electric propulsion (SEP) vehicles and missions. This paper describes a 30-kW electric propulsion vehicle built into an EELV Secondary Payload Adapter (ESPA) ring. The system uses an ESPA ring as the primary structure and packages two 15-kW Megaflex solar array wings, two 14-kW Hall thrusters, a hydrazine Reaction Control Subsystem (RCS), 220 kg of xenon, 26 kg of hydrazine, and an avionics module that contains all of the rest of the spacecraft bus functions and the instrument suite. Direct-drive is used to maximize the propulsion subsystem efficiency and minimize the resulting waste heat and required radiator area. This is critical for packaging a high-power spacecraft into a very small volume. The fully-margined system dry mass would be approximately 1120 kg. This is not a small dry mass for a Discovery-class spacecraft, for example, the Dawn spacecraft dry mass was only about 750 kg. But the Dawn electric propulsion subsystem could process a maximum input power of 2.5 kW, and this spacecraft would process 28 kW, an increase of more than a factor of ten. With direct-drive the specific impulse would be limited to about 2,000 s assuming a nominal solar array output voltage of 300 V. The resulting spacecraft would have a beginning of life acceleration that is more than an order of magnitude greater than the Dawn spacecraft. Since the spacecraft would be built into an ESPA ring it could be launched as a secondary payload to a geosynchronous transfer orbit significantly reducing the launch costs for a planetary spacecraft. The SEP system would perform the escape

  8. Framework for sequential approximate optimization

    NARCIS (Netherlands)

    Jacobs, J.H.; Etman, L.F.P.; Keulen, van F.; Rooda, J.E.

    2004-01-01

    An object-oriented framework for Sequential Approximate Optimization (SAO) isproposed. The framework aims to provide an open environment for thespecification and implementation of SAO strategies. The framework is based onthe Python programming language and contains a toolbox of Python

  9. Antenatal magnesium sulphate may prevent cerebral palsy in preterm infants--but are we convinced? Evaluation of an apparently conclusive meta-analysis with trial sequential analysis

    DEFF Research Database (Denmark)

    Huusom, L D; Secher, N J; Pryds, O

    2011-01-01

    Please cite this paper as: Huusom L, Secher N, Pryds O, Whitfield K, Gluud C, Brok J. Antenatal magnesium sulphate may prevent cerebral palsy in preterm infants-but are we convinced? Evaluation of an apparently conclusive meta-analysis with trial sequential analysis. BJOG 2011;118:1-5....

  10. A Survey of Multi-Objective Sequential Decision-Making

    OpenAIRE

    Roijers, D.M.; Vamplew, P.; Whiteson, S.; Dazeley, R.

    2013-01-01

    Sequential decision-making problems with multiple objectives arise naturally in practice and pose unique challenges for research in decision-theoretic planning and learning, which has largely focused on single-objective settings. This article surveys algorithms designed for sequential decision-making problems with multiple objectives. Though there is a growing body of literature on this subject, little of it makes explicit under what circumstances special methods are needed to solve multi-obj...

  11. A Sequential Multiplicative Extended Kalman Filter for Attitude Estimation Using Vector Observations

    Science.gov (United States)

    Qin, Fangjun; Jiang, Sai; Zha, Feng

    2018-01-01

    In this paper, a sequential multiplicative extended Kalman filter (SMEKF) is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms. PMID:29751538

  12. A Sequential Multiplicative Extended Kalman Filter for Attitude Estimation Using Vector Observations

    Directory of Open Access Journals (Sweden)

    Fangjun Qin

    2018-05-01

    Full Text Available In this paper, a sequential multiplicative extended Kalman filter (SMEKF is proposed for attitude estimation using vector observations. In the proposed SMEKF, each of the vector observations is processed sequentially to update the attitude, which can make the measurement model linearization more accurate for the next vector observation. This is the main difference to Murrell’s variation of the MEKF, which does not update the attitude estimate during the sequential procedure. Meanwhile, the covariance is updated after all the vector observations have been processed, which is used to account for the special characteristics of the reset operation necessary for the attitude update. This is the main difference to the traditional sequential EKF, which updates the state covariance at each step of the sequential procedure. The numerical simulation study demonstrates that the proposed SMEKF has more consistent and accurate performance in a wide range of initial estimate errors compared to the MEKF and its traditional sequential forms.

  13. Asynchronous Operators of Sequential Logic Venjunction & Sequention

    CERN Document Server

    Vasyukevich, Vadim

    2011-01-01

    This book is dedicated to new mathematical instruments assigned for logical modeling of the memory of digital devices. The case in point is logic-dynamical operation named venjunction and venjunctive function as well as sequention and sequentional function. Venjunction and sequention operate within the framework of sequential logic. In a form of the corresponding equations, they organically fit analytical expressions of Boolean algebra. Thus, a sort of symbiosis is formed using elements of asynchronous sequential logic on the one hand and combinational logic on the other hand. So, asynchronous

  14. Language Acquisition without an Acquisition Device

    Science.gov (United States)

    O'Grady, William

    2012-01-01

    Most explanatory work on first and second language learning assumes the primacy of the acquisition phenomenon itself, and a good deal of work has been devoted to the search for an "acquisition device" that is specific to humans, and perhaps even to language. I will consider the possibility that this strategy is misguided and that language…

  15. Abdominal CT: An intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake, E-mail: yamada@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Jinzaki, Masahiro, E-mail: jinzaki@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Hosokawa, Takahiro, E-mail: snowglobe@infoseek.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Tanami, Yutaka, E-mail: tanami@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Abe, Takayuki, E-mail: tabe@z5.keio.jp [Center for Clinical Research, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Kuribayashi, Sachio, E-mail: skuribay@med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan)

    2014-10-15

    Highlights: • We compared virtual monochromatic spectral (VMS) images with 120-kVp images. • VMS images are generated using accurate two-material beam-hardening correction. • Abdominal 70-keV VMS images provide better image quality than 120-kVp images. • Iterative reconstruction can further improve the image quality of VMS images. - Abstract: Objectives: To compare quantitative and subjective image quality between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp imaging performed during the same abdominal computed tomography (CT) examination. Materials and methods: Our institutional review board approved this prospective study; each participant provided written informed consent. 51 patients underwent sequential fast kVp-switching dual-energy (80/140 kVp, volume CT dose index: 12.7 mGy) and single-energy (120-kVp, 12.7 mGy) abdominal enhanced CT over an 8 cm scan length with a random acquisition order and a 4.3-s interval. VMS images with filtered back projection (VMS-FBP) and adaptive statistical iterative reconstruction (so-called hybrid IR) (VMS-ASIR) (at 70 keV), as well as 120-kVp images with FBP (120-kVp-FBP) and ASIR (120-kVp-ASIR), were generated from dual-energy and single-energy CT data, respectively. The objective image noises, signal-to-noise ratios and contrast-to-noise ratios of the liver, kidney, pancreas, spleen, portal vein and aorta, and the lesion-to-liver and lesion-to-kidney contrast-to-noise ratios were measured. Two radiologists independently and blindly assessed the subjective image quality. The results were analyzed using the paired t-test, Wilcoxon signed rank sum test and mixed-effects model with Bonferroni correction. Results: VMS-ASIR images were superior to 120-kVp-FBP, 120-kVp-ASIR and VMS-FBP images for all the quantitative assessments and the subjective overall image quality (all P < 0.001), while VMS-FBP images were superior to 120-kVp-FBP and 120-kVp-ASIR images (all P < 0.004). Conclusions: VMS

  16. Abdominal CT: An intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination

    International Nuclear Information System (INIS)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hosokawa, Takahiro; Tanami, Yutaka; Abe, Takayuki; Kuribayashi, Sachio

    2014-01-01

    Highlights: • We compared virtual monochromatic spectral (VMS) images with 120-kVp images. • VMS images are generated using accurate two-material beam-hardening correction. • Abdominal 70-keV VMS images provide better image quality than 120-kVp images. • Iterative reconstruction can further improve the image quality of VMS images. - Abstract: Objectives: To compare quantitative and subjective image quality between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp imaging performed during the same abdominal computed tomography (CT) examination. Materials and methods: Our institutional review board approved this prospective study; each participant provided written informed consent. 51 patients underwent sequential fast kVp-switching dual-energy (80/140 kVp, volume CT dose index: 12.7 mGy) and single-energy (120-kVp, 12.7 mGy) abdominal enhanced CT over an 8 cm scan length with a random acquisition order and a 4.3-s interval. VMS images with filtered back projection (VMS-FBP) and adaptive statistical iterative reconstruction (so-called hybrid IR) (VMS-ASIR) (at 70 keV), as well as 120-kVp images with FBP (120-kVp-FBP) and ASIR (120-kVp-ASIR), were generated from dual-energy and single-energy CT data, respectively. The objective image noises, signal-to-noise ratios and contrast-to-noise ratios of the liver, kidney, pancreas, spleen, portal vein and aorta, and the lesion-to-liver and lesion-to-kidney contrast-to-noise ratios were measured. Two radiologists independently and blindly assessed the subjective image quality. The results were analyzed using the paired t-test, Wilcoxon signed rank sum test and mixed-effects model with Bonferroni correction. Results: VMS-ASIR images were superior to 120-kVp-FBP, 120-kVp-ASIR and VMS-FBP images for all the quantitative assessments and the subjective overall image quality (all P < 0.001), while VMS-FBP images were superior to 120-kVp-FBP and 120-kVp-ASIR images (all P < 0.004). Conclusions: VMS

  17. Using the "K[subscript 5]Connected Cognition Diagram" to Analyze Teachers' Communication and Understanding of Regions in Three-Dimensional Space

    Science.gov (United States)

    Moore-Russo, Deborah; Viglietti, Janine M.

    2012-01-01

    This paper reports on a study that introduces and applies the "K[subscript 5]Connected Cognition Diagram" as a lens to explore video data showing teachers' interactions related to the partitioning of regions by axes in a three-dimensional geometric space. The study considers "semiotic bundles" (Arzarello, 2006), introduces "semiotic connections,"…

  18. Duality relations between SU(N)k and SU(k)NWZW models and their braid matrices

    International Nuclear Information System (INIS)

    Naculich, S.G.; Schnitzer, H.J.

    1990-01-01

    Dual relations are found between the primary fields, correlators, and conformal blocks of SU(N) k and SU(k) N WZW models, which in turn imply dual relations between the braid matrices of the two theories. These results are a consequence of the fact that the spaces of conformal blocks of SU(N) k and SU(k) N correlation functions are dual. (orig.)

  19. Data acquisition system for segmented reactor antineutrino detector

    Czech Academy of Sciences Publication Activity Database

    Hons, Zdeněk; Vlášek, J.

    2017-01-01

    Roč. 12, č. 1 (2017), č. článku P01022. ISSN 1748-0221 R&D Projects: GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : Data acquisition concepts * Detector control systems (detector and experiment monitoring and slow-control system, architecture , hardware, algorithms, databases) * Neutrino detectors Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders OBOR OECD: Nuclear physics Impact factor: 1.220, year: 2016

  20. Working Papers in Acquisition of Knowledge for Image Understanding Research,

    Science.gov (United States)

    1976-12-15

    Rmvt 112,7,P IM Y. K3p ’Of’ z4-" odK zw Mw; OW, ev 6 "ONO T;I 11; "VI lip, IA wo 44 jo . ... . ...... I I WORKING PAPERS IN ACQUISITION OF...paradigm than any other. They have collected protocolt on subjects verbally describing scenes, after examining them visually. The control variable they... collection of Elements of Control Flow (ECF). To avoid creation of either file, the user presses the return key without typing a name to the respective

  1. Human visual system automatically encodes sequential regularities of discrete events.

    Science.gov (United States)

    Kimura, Motohiro; Schröger, Erich; Czigler, István; Ohira, Hideki

    2010-06-01

    For our adaptive behavior in a dynamically changing environment, an essential task of the brain is to automatically encode sequential regularities inherent in the environment into a memory representation. Recent studies in neuroscience have suggested that sequential regularities embedded in discrete sensory events are automatically encoded into a memory representation at the level of the sensory system. This notion is largely supported by evidence from investigations using auditory mismatch negativity (auditory MMN), an event-related brain potential (ERP) correlate of an automatic memory-mismatch process in the auditory sensory system. However, it is still largely unclear whether or not this notion can be generalized to other sensory modalities. The purpose of the present study was to investigate the contribution of the visual sensory system to the automatic encoding of sequential regularities using visual mismatch negativity (visual MMN), an ERP correlate of an automatic memory-mismatch process in the visual sensory system. To this end, we conducted a sequential analysis of visual MMN in an oddball sequence consisting of infrequent deviant and frequent standard stimuli, and tested whether the underlying memory representation of visual MMN generation contains only a sensory memory trace of standard stimuli (trace-mismatch hypothesis) or whether it also contains sequential regularities extracted from the repetitive standard sequence (regularity-violation hypothesis). The results showed that visual MMN was elicited by first deviant (deviant stimuli following at least one standard stimulus), second deviant (deviant stimuli immediately following first deviant), and first standard (standard stimuli immediately following first deviant), but not by second standard (standard stimuli immediately following first standard). These results are consistent with the regularity-violation hypothesis, suggesting that the visual sensory system automatically encodes sequential

  2. Impact of Diagrams on Recalling Sequential Elements in Expository Texts.

    Science.gov (United States)

    Guri-Rozenblit, Sarah

    1988-01-01

    Examines the instructional effectiveness of abstract diagrams on recall of sequential relations in social science textbooks. Concludes that diagrams assist significantly the recall of sequential relations in a text and decrease significantly the rate of order mistakes. (RS)

  3. Multiple acquisition of magic angle spinning solid-state NMR experiments using one receiver: Application to microcrystalline and membrane protein preparations

    Science.gov (United States)

    Gopinath, T.; Veglia, Gianluigi

    2015-04-01

    Solid-state NMR spectroscopy of proteins is a notoriously low-throughput technique. Relatively low-sensitivity and poor resolution of protein samples require long acquisition times for multidimensional NMR experiments. To speed up data acquisition, we developed a family of experiments called Polarization Optimized Experiments (POE), in which we utilized the orphan spin operators that are discarded in classical multidimensional NMR experiments, recovering them to allow simultaneous acquisition of multiple 2D and 3D experiments, all while using conventional probes with spectrometers equipped with one receiver. POE allow the concatenation of multiple 2D or 3D pulse sequences into a single experiment, thus potentially combining all of the aforementioned advances, boosting the capability of ssNMR spectrometers at least two-fold without the addition of any hardware. In this perspective, we describe the first generation of POE, such as dual acquisition MAS (or DUMAS) methods, and then illustrate the evolution of these experiments into MEIOSIS, a method that enables the simultaneous acquisition of multiple 2D and 3D spectra. Using these new pulse schemes for the solid-state NMR investigation of biopolymers makes it possible to obtain sequential resonance assignments, as well as distance restraints, in about half the experimental time. While designed for acquisition of heteronuclei, these new experiments can be easily implemented for proton detection and coupled with other recent advancements, such as dynamic nuclear polarization (DNP), to improve signal to noise. Finally, we illustrate the application of these methods to microcrystalline protein preparations as well as single and multi-span membrane proteins reconstituted in lipid membranes.

  4. Quantum Probability Zero-One Law for Sequential Terminal Events

    Science.gov (United States)

    Rehder, Wulf

    1980-07-01

    On the basis of the Jauch-Piron quantum probability calculus a zero-one law for sequential terminal events is proven, and the significance of certain crucial axioms in the quantum probability calculus is discussed. The result shows that the Jauch-Piron set of axioms is appropriate for the non-Boolean algebra of sequential events.

  5. Concatenated coding system with iterated sequential inner decoding

    DEFF Research Database (Denmark)

    Jensen, Ole Riis; Paaske, Erik

    1995-01-01

    We describe a concatenated coding system with iterated sequential inner decoding. The system uses convolutional codes of very long constraint length and operates on iterations between an inner Fano decoder and an outer Reed-Solomon decoder......We describe a concatenated coding system with iterated sequential inner decoding. The system uses convolutional codes of very long constraint length and operates on iterations between an inner Fano decoder and an outer Reed-Solomon decoder...

  6. Free-piston Stirling technology for space power

    International Nuclear Information System (INIS)

    Slaby, J.G.

    1994-01-01

    An overview is presented of the NASA Lewis Research Center free-piston Stirling engine activities directed toward space power. This work is being carried out under NASA's new Civil Space Technology Initiative (CSTI). The overall goal of CSTI's High Capacity Power element is to develop the technology base needed to meet the long duration, high capacity power requirements for future NASA space missions. The Stirling cycle offers an attractive power conversion concept for space power needs. Discussed in this paper is the completion of the Space Power Demonstrator Engine (SPDE) testing - culminating in the generation of 25 kW of engine power from a dynamically-balanced opposed-piston Stirling engine at a temperature ratio of 2.0. Engine efficiency was approximately 22 percent. The SPDE recently has been divided into two separate single-cylinder engines, called Space Power Research Engines (SPRE), that now serve as test beds for the evaluation of key technology disciplines. These disciplines include hydrodynamic gas bearings, high-efficiency linear alternators, space qualified heat pipe heat exchangers, oscillating flow code validation, and engine loss understanding. The success of the SPDE at 650 K has resulted in a more ambitious Stirling endeavor - the design, fabrication, test and evaluation of a designed-for-space 25 kW per cylinder Stirling Space Engine (SSE). The SSE will operate at a hot metal temperature of 1050 K using superalloy materials. This design is a low temperature confirmation of the 1300 K design. It is the 1300 K free-piston Stirling power conversion system that is the ultimate goal; to be used in conjunction with the SP-100 reactor. The approach to this goal is in three temperature steps. However, this paper concentrates on the first two phases of this program - the 650 K SPDE and the 1050 K SSE

  7. Space science technology: In-situ science. Sample Acquisition, Analysis, and Preservation Project summary

    Science.gov (United States)

    Aaron, Kim

    1991-01-01

    The Sample Acquisition, Analysis, and Preservation Project is summarized in outline and graphic form. The objective of the project is to develop component and system level technology to enable the unmanned collection, analysis and preservation of physical, chemical and mineralogical data from the surface of planetary bodies. Technology needs and challenges are identified and specific objectives are described.

  8. Memory of conditioned taste aversion is erased by inhibition of PI3K in the insular cortex.

    Science.gov (United States)

    Slouzkey, Ilana; Rosenblum, Kobi; Maroun, Mouna

    2013-06-01

    The conditioned taste aversion (CTA) paradigm, in which association between a novel taste and visceral malaise is formed, gives a unique experimental setting to examine the mechanisms underlying memory acquisition and extinction processes. AKT is a main kinase of the phosphoinositide 3-kinase cascade (PI3K) and has been implicated in long-term memory. We have recently reported that blockade of PI3K in the basolateral amygdala (BLA) before retrieval of fear memory was associated with long-term reduction in fear responses, suggesting a possible role of PI3K inhibition in fear erasure. In this study, we aimed to elucidate whether PI3K has a similar role in the insular cortex (IC), which has a crucial role in CTA acquisition, consolidation, maintenance, and extinction. To that end, we (1) monitored AKT phosphorylation in the IC following CTA acquisition and extinction and (2) inhibited PI3K by local microinjection of the PI3K inhibitor LY294002 at different stages of CTA acquisition and extinction. Our results show that while AKT phosphorylation is increased following CTA learning, it is decreased following CTA extinction. Inhibition of AKT phosphorylation in the IC before or after the first CTA retrieval test resulted in reduction in the aversion index. This reduction in aversion is due to the erasure of the original CTA trace memory, as re-application of the unconditioned stimulus (lithium chloride) did not induce the recovery of aversion in LY294002-treated animals. Our present data add new evidence to suggest that PI3K is engaged in consolidation of aversive memories, as its inhibition is associated with erasure of CTA memory.

  9. Lineup Composition, Suspect Position, and the Sequential Lineup Advantage

    Science.gov (United States)

    Carlson, Curt A.; Gronlund, Scott D.; Clark, Steven E.

    2008-01-01

    N. M. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001) argued that sequential lineups reduce the likelihood of mistaken eyewitness identification. Experiment 1 replicated the design of R. C. L. Lindsay and G. L. Wells (1985), the first study to show the sequential lineup advantage. However, the innocent suspect was chosen at a lower rate…

  10. Trial Sequential Analysis in systematic reviews with meta-analysis

    Directory of Open Access Journals (Sweden)

    Jørn Wetterslev

    2017-03-01

    Full Text Available Abstract Background Most meta-analyses in systematic reviews, including Cochrane ones, do not have sufficient statistical power to detect or refute even large intervention effects. This is why a meta-analysis ought to be regarded as an interim analysis on its way towards a required information size. The results of the meta-analyses should relate the total number of randomised participants to the estimated required meta-analytic information size accounting for statistical diversity. When the number of participants and the corresponding number of trials in a meta-analysis are insufficient, the use of the traditional 95% confidence interval or the 5% statistical significance threshold will lead to too many false positive conclusions (type I errors and too many false negative conclusions (type II errors. Methods We developed a methodology for interpreting meta-analysis results, using generally accepted, valid evidence on how to adjust thresholds for significance in randomised clinical trials when the required sample size has not been reached. Results The Lan-DeMets trial sequential monitoring boundaries in Trial Sequential Analysis offer adjusted confidence intervals and restricted thresholds for statistical significance when the diversity-adjusted required information size and the corresponding number of required trials for the meta-analysis have not been reached. Trial Sequential Analysis provides a frequentistic approach to control both type I and type II errors. We define the required information size and the corresponding number of required trials in a meta-analysis and the diversity (D2 measure of heterogeneity. We explain the reasons for using Trial Sequential Analysis of meta-analysis when the actual information size fails to reach the required information size. We present examples drawn from traditional meta-analyses using unadjusted naïve 95% confidence intervals and 5% thresholds for statistical significance. Spurious conclusions in

  11. Assured Mission Support Space Architecture (AMSSA) study

    Science.gov (United States)

    Hamon, Rob

    1993-01-01

    The assured mission support space architecture (AMSSA) study was conducted with the overall goal of developing a long-term requirements-driven integrated space architecture to provide responsive and sustained space support to the combatant commands. Although derivation of an architecture was the focus of the study, there are three significant products from the effort. The first is a philosophy that defines the necessary attributes for the development and operation of space systems to ensure an integrated, interoperable architecture that, by design, provides a high degree of combat utility. The second is the architecture itself; based on an interoperable system-of-systems strategy, it reflects a long-range goal for space that will evolve as user requirements adapt to a changing world environment. The third product is the framework of a process that, when fully developed, will provide essential information to key decision makers for space systems acquisition in order to achieve the AMSSA goal. It is a categorical imperative that military space planners develop space systems that will act as true force multipliers. AMSSA provides the philosophy, process, and architecture that, when integrated with the DOD requirements and acquisition procedures, can yield an assured mission support capability from space to the combatant commanders. An important feature of the AMSSA initiative is the participation by every organization that has a role or interest in space systems development and operation. With continued community involvement, the concept of the AMSSA will become a reality. In summary, AMSSA offers a better way to think about space (philosophy) that can lead to the effective utilization of limited resources (process) with an infrastructure designed to meet the future space needs (architecture) of our combat forces.

  12. The OmegaCAM 16K x 16K CCD detector system for the ESO VLT Survey Telescope (VST)

    Science.gov (United States)

    Iwert, Olaf; Baade, D.; Balestra, A.; Baruffolo, A.; Bortolussi, A.; Christen, F.; Cumani, C.; Deiries, S.; Downing, M.; Geimer, C.; Hess, G.; Hess, J.; Kuijken, K.; Lizon, J.; Muschielok, B.; Nicklas, H.; Reiss, R.; Reyes, J.; Silber, A.; Thillerup, J.; Valentijn, E.

    2006-06-01

    A 16K x 16K, 1 degree x 1 degree field, detector system was developed by ESO for the OmegaCAM instrument for use on the purpose built ESO VLT Survey Telescope (VST). The focal plane consists of an 8 x 4 mosaic of 2K x 4K 15um pixel e2v CCDs and four 2K x 4K CCDs on the periphery for the opto-mechanical control of the telescope. The VST is a single instrument telescope. This placed stringent reliability requirements on the OmegaCAM detector system such as 10 years lifetime and maximum downtime of 1.5 %. Mounting at Cassegrain focus required a highly autonomous self-contained cooling system that could deliver 65 W of cooling power. Interface space for the detector head was severely limited by the way the instrument encloses the CCD cryostat. The detector system features several novel ideas tailored to meet these requirements and described in this paper: Key design drivers of the detector head were the easily separable but precisely aligned connections to the optical field flattener on the top and the cooling system at the bottom. Material selection, surface treatment, specialized coatings and in-situ plasma cleaning were crucial to prevent contamination of the detectors. Inside the cryostat, cryogenic and electrical connections were disentangled to keep the configuration modular, integration friendly and the detectors in a safe condition during all mounting steps. A compact unit for logging up to 125 Pt100 temperature sensors and associated thermal control loops was developed (ESO's new housekeeping unit PULPO 2), together with several new modular Pt100 packaging and mounting concepts. The electrical grouping of CCDs based on process parameters and test results is explained. Three ESO standardized FIERA CCD controllers in different configurations are used. Their synchronization mechanism for read-out is discussed in connection with the CCD grouping scheme, the shutter, and the integrated guiding and image analysis facility with four independent 2K x 4K CCDs. An

  13. Management and Oversight of Services Acquisition Within the United States Air Force

    Science.gov (United States)

    2008-12-01

    Air Mobility Command AFDW Air Force District of Washington AFSPC Air Force Space Command AT&L Acquisition Technologies and Logistics CPM ...were commonly performed in industry. The types of services included advertising for Navy recruitment, custodial services on Air Force bases, and on

  14. Development of a custom monolithic device for data acquisition from a scintillating calorimeter at the superconducting super collider

    International Nuclear Information System (INIS)

    Ekenberg, T.; Dawson, J.W.; Talaga, R.L.; Stevens, A.E.; Haberichter, W.N.

    1991-01-01

    A clock-driven continuous sequential write/random read data acquisition architecture for a scintillating calorimeter at the SSC is presented. Simplicity of design and operation as well as potentially dead time-less operation are the motivations of this effort. The architecture minimizes the number of fast control signals, thereby reducing pickup from digital control lines by sensitive analog circuits in the front-end device. This architecture also reduces the logic necessary on the front-end device improving reliability and easing design and operation. Operation and design of the front-end device are discussed. 3 refs., 7 figs

  15. K/sup -/n and K/sup -/p elastic scattering in K/sup -/d collisions from 12 to 22 GeV/c

    CERN Document Server

    Déclais, Y; Bricman, C; Duchon, J; Ferro-Luzzi, M; Louvel, M; Patry, J P; Perreau, J M; Séguinot, Jacques; Ypsilantis, Thomas

    1977-01-01

    The elastic scattering of negative K-mesons on the proton and on the neutron of the deuterium has been measured at six incident momenta equally spaced between 1.2 and 2.2 GeV/c. Differential cross sections over the almost complete angular range have been obtained for K/sup - /p and K/sup -/n. The aim of the experiment was the measurement of the pure isospin I=1 reaction K/sup -/n to K/sup -/n. The results for the reaction on proton are a by-product and provide a verification of the assumptions necessary for the analysis of the neutron reaction.

  16. Cognition and learning in space technology

    Directory of Open Access Journals (Sweden)

    Kelber Ruhena Abrão

    2016-12-01

    Full Text Available This work analyzes the impact of new technologies in everyday teaching situations. This is a qualitative research, one study of descriptive case, based on observations of the spaces of the classrooms, the same group of children between June 2013 and April 2015, the 1st, 2nd and 3rd years of Primary Education a Catholic private school, as well as interviews with the regents’ teachers of these classes. We seek to establish links between the acquisition of written language in conventional texts and those in hypertext, as well as understand how to structure the scientific and digital literacy in these areas. In that sense, it was found that these experiences are possible to happen in designed spaces antagonistically to traditional spaces as often, it is less rigid, more flexible, a fact that makes the pleasant atmosphere and at the same time, more accessible, providing an environment sometimes hybrid, in which the dimensions of notebook and tablet coexist and fusion of these opposed pairs of written language acquisition occurs.

  17. Cost-effectiveness of simultaneous versus sequential surgery in head and neck reconstruction.

    Science.gov (United States)

    Wong, Kevin K; Enepekides, Danny J; Higgins, Kevin M

    2011-02-01

    To determine whether simultaneous (ablation and reconstruction overlaps by two teams) head and neck reconstruction is cost effective compared to sequentially (ablation followed by reconstruction) performed surgery. Case-controlled study. Tertiary care hospital. Oncology patients undergoing free flap reconstruction of the head and neck. A match paired comparison study was performed with a retrospective chart review examining the total time of surgery for sequential and simultaneous surgery. Nine patients were selected for both the sequential and simultaneous groups. Sequential head and neck reconstruction patients were pair matched with patients who had undergone similar oncologic ablative or reconstructive procedures performed in a simultaneous fashion. A detailed cost analysis using the microcosting method was then undertaken looking at the direct costs of the surgeons, anesthesiologist, operating room, and nursing. On average, simultaneous surgery required 3 hours 15 minutes less operating time, leading to a cost savings of approximately $1200/case when compared to sequential surgery. This represents approximately a 15% reduction in the cost of the entire operation. Simultaneous head and neck reconstruction is more cost effective when compared to sequential surgery.

  18. SpaceTwist

    DEFF Research Database (Denmark)

    Yiu, Man Lung; Jensen, Christian Søndergaard; Xuegang, Huang

    2008-01-01

    -based matching generally fall short in offering practical query accuracy guarantees. Our proposed framework, called SpaceTwist, rectifies these shortcomings for k nearest neighbor (kNN) queries. Starting with a location different from the user's actual location, nearest neighbors are retrieved incrementally...

  19. DAISY - the Oslo Cyclotron data acquisition system

    International Nuclear Information System (INIS)

    Ramsoey, T.

    1991-08-01

    The new CACTUS multidetector system for the Oslo Cyclotron consists of 8 particle telescopes, 28 NAI detectors and 2 Ge detectors. Each detector gives rise to one energy parameter and one time parameter. Thus, a total of 80 parameters are present. The counting rate is 100 kByte/s for the highest beam intensities. A new data acquisition system, DAISY, satisfying these demands has been designed. The present report is intended as a complete technical manual for the new system. 24 refs

  20. Dihydroazulene photoswitch operating in sequential tunneling regime

    DEFF Research Database (Denmark)

    Broman, Søren Lindbæk; Lara-Avila, Samuel; Thisted, Christine Lindbjerg

    2012-01-01

    to electrodes so that the electron transport goes by sequential tunneling. To assure weak coupling, the DHA switching kernel is modified by incorporating p-MeSC6H4 end-groups. Molecules are prepared by Suzuki cross-couplings on suitable halogenated derivatives of DHA. The synthesis presents an expansion of our......, incorporating a p-MeSC6H4 anchoring group in one end, has been placed in a silver nanogap. Conductance measurements justify that transport through both DHA (high resistivity) and VHF (low resistivity) forms goes by sequential tunneling. The switching is fairly reversible and reenterable; after more than 20 ON...