WorldWideScience

Sample records for sensitive photomultiplier tube

  1. photomultiplier tubes

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  2. photomultiplier tube

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  3. photomultiplier tube

    CERN Multimedia

    A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  4. photomultiplier tube

    CERN Multimedia

    Philips. 150AVP. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  5. Development of 2D-ACAR apparatus using position-sensitive photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, Yasuyoshi; Saito, Haruo; Iwata, Tetsuya; Nagashima, Yasuyuki; Hyodo, Toshio [Tokyo Univ. (Japan). Coll. of Arts and Sciences; Uchida, Hiroshi; Omura, Tomohide

    1997-03-01

    A new two-dimensional angular correlation of annihilation radiation apparatus is described. Position-sensitive photomultiplier tubes coupled with two-dimensional arrays of small BGO scintillator blocks make simple and compact position-sensitive {gamma}-ray detectors. With a sample-detector distance of 5m, an angular resolution of 1.1 mrad FWHM and a coincidence count rate of {approx}2.4 c.p.s. per mCi are obtained. Its performance is demonstrated by the result of a test measurement for KI crystal in which non-localized positronium exists at low temperatures. (author)

  6. Radionuclide mapping using a position sensitive photomultiplier tube and a germanium detector

    International Nuclear Information System (INIS)

    Dewaraja, Y.K.; He, Z.; Fleming, R.F.; Wehe, D.K.; Fleming, R.H.

    1995-01-01

    This paper demonstrates simultaneous two-dimensional mapping of multiple radionuclides which are present in a sample. The technique, which is based on position sensitive beta-gamma coincidence measurement, is applicable to most radionuclides that decay by beta emission followed by the emission of a coincident gamma-ray. In the present works, a Position Sensitive Photomultiplier Tube [PSPMT] is used for imaging the beta particles while a Ge detector is used to identify the radionuclides by detecting the coincident gamma-rays

  7. An overview of current developments in position-sensitive hybrid photon detectors and photo-multiplier tubes

    CERN Document Server

    Gys, Thierry

    1999-01-01

    Current developments in position-sensitive hybrid photon detectors and photo-multiplier tubes have stimulated increased interest from a variety of fields such as astronomy, biomedical imaging and high- energy physics. These devices are sensitive to single photons over a photon energy spectrum defined by the transmission of the optical entrance window and the photo-cathode type. Their spatial resolution ranges from a few millimeters for pad hybrid photon detectors and multi-anode photo-multiplier tubes down to a few tens of microns for pixel hybrid photon detectors and electron-bombarded charge-coupled devices. Basic technological and design aspects are assessed in this paper. (21 refs).

  8. Position sensitive gaseous photomultipliers

    CERN Document Server

    Biteman, V; Peskov, Vladimir; Sakuraï, H; Silin, E; Sokolova, T; Radionov, I

    2001-01-01

    In this paper a simple design of a gaseous photomultiplier, sensitive up to visible light, is described. It consists of a parallel plate chamber combined with a solid photocathode through a capillary plate, which works in a transmission mode and serves to suppress photon feedback. Ion feedback was minimized through the optimization of the gas mixture. A gain >10 sup 3 was achieved.

  9. An anti-Cherenkov photomultiplier tube

    International Nuclear Information System (INIS)

    Selove, W.; Cormell, L.R.; Dris, M.; Kononenko, W.; Robinson, B.; Yost, B.T.

    1982-01-01

    We have designed a special photomultiplier tube (PMT), with very much reduced sensitivity to Cherenkov light produced in the end window. These PMTs have been produced for us by EMI, and have been used in a modular calorimeter array. The design eliminates a 'hot-spot' problem which was of intolerable magnitude in our application. (orig.)

  10. Scintillation counter: photomultiplier tube alignment

    International Nuclear Information System (INIS)

    Olson, R.E.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into the sample receiving zone. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (auth)

  11. A position-sensitive scintillation detector for two-dimensional angular correlation of annihilation radiation using metal-package position-sensitive photomultiplier tubes

    International Nuclear Information System (INIS)

    Inoue, Koji; Nagai, Yasuyoshi; Saito, Haruo; Nagashima, Yasuyuki; Hyodo, Toshio; Muramatsu, Shinichi; Nagai, Shota

    1999-01-01

    We have constructed and tested a prototype of a new position sensitive γ-ray detector which consists of an array of 2.6x2.6x18 mm 3 BGO scintillator blocks, a light guide, and four metal-package position-sensitive photomultiplier tubes (R5900-00-C8) recently developed by Hamamatsu Photonics Co. Ltd. Scalability of the detector of this type makes it possible to construct a larger detector using many PS-PMTs, which will be useful for the two-dimensional angular correlation of annihilation radiation apparatus

  12. Position Sensitive Gaseous Photomultipliers

    CERN Document Server

    Martinengo, P; Peskov, V

    2010-01-01

    Advances in the technologies associated with position sensitive gaseous detectors especially featuring CsI as reflective photoconverters will be reviewed. These photodetectors represent the most effective solution for what concerns cost and performance in the case of large area Cherenkov imaging applications in relatively low rate (or low occupancy) high energy physics and astrophysics experiments. Moreover, they are the only choice when the Cherenkov detector is embedded in a magnetic field. Recently proposed single photon MPGDs (Micropattern Gaseous Detectors) will be also discussed in view of the successful efforts so far made to extend their sensitivity to visible light. With some modifications, photosensitive gaseous detectors can also be used in the imaging of X-rays and particles.

  13. Performance of the hybrid photomultiplier tube (HPMT)

    Energy Technology Data Exchange (ETDEWEB)

    Schomaker, R.J. [B.V. Delft Electronische Producten, Roden (Netherlands)

    1995-12-31

    The HPMT, which may be an alternative for PhotoMultiplier Tubes (PMT`s) in many applications, is a vacuum tube in which the latest technologies of photocathodes and photodiodes are combined. Photo-electrons are accelerated and bombarding a reversely biased PIN diode, where they create many electron-hole-pairs. The resulting charge pulse can be amplified and further processed. The HPMT shows many superior characteristics compared to regular PMT`s, because it does not suffer the statistical fluctuations common for electron multiplication processes. An energy resolution of up to 14 photo-electrons will be presented, together with striking figures for dynamic range and timing behavior.

  14. Improving the performance of photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Harmer, S W [Department of Engineering and Technology, Manchester Metropolitan University, Manchester M1 5GD (United Kingdom); Townsend, P D, E-mail: pdtownsend@googlemail.co [Science and Technology, University of Sussex, Brighton BN1 9QH (United Kingdom)

    2010-10-20

    Photomultipliers are ubiquitous detectors of low level light signals, but their performance is limited by the complexity of photocathode technology. Two contributory problems are that light is lost both by surface reflection and by transmission through the photocathode layer. Knowledge of the dielectric constants has allowed predictive modelling of the reflectivity and absorption of the light as a function of angle of incidence, cathode thickness and polarization. The predictions have stimulated designs of extremely simple and very low cost retrofit approaches to improve the overall effectiveness of photomultipliers. One simple design presented here exploits signal that is normally lost by the surface reflection. A simple external conical torch reflector is clipped over the photomultiplier end face. The reflector raised the efficiency of an S20 multialkali photocathode by between 20% and 10% across the blue to red spectral range. An alternative semi-cylindrical glass coupler has improved the absorption efficiency by allowing the input signal to arrive at 60{sup 0} incidence to the photocathode surface, rather than normal incidence as in the standard head-on geometry. Enhancements are from 30% to 500% across the spectral range. The greater gains are at long wavelengths, and so are particularly valuable as this is the region of lowest quantum efficiency. The latter high-incidence angle approach, when applied to a low-efficiency C grade tube, has raised the performance to greater than the best of the A grade tubes, as used in the normal head-on operation. Both methods are equally applicable to other cathode compositions.

  15. Cathode uniformity of new square photomultiplier tubes

    International Nuclear Information System (INIS)

    Brenner, R.; Chou, H.P.; Strauss, M.G.; Winiecki, A.L.

    1981-01-01

    Square photomultiplier tubes (PMTs) should have better light collection than round PMTs when used in square or rectangular Anger-type #betta#-ray or neutron position detectors. Photocathode response uniformity of new RCA square PMTs type S83003E (51.5 x 51.5 mm 2 ) was measured and compared with conventional round PMTs. The PMTs were scanned with a small scintillation source while the anode signal amplitudes were processed in a computer-based multichannel analyzer. The analyzer was programmed in a mode which virtually eliminates effects due to statistical fluctuations in source rate and output amplitude. Pulse heights as a function of source position on the PMT face are shown for typical tubes. The response uniformity of 64 square PMTs and 21 round ones was evaluated. It is shown that the center region of the square PMTs is as uniform as that of the round ones and that the response in the corners is comparable to that in the center. Thus square PMTs appear to have an advantage for use in square or rectangular position detectors

  16. A Cockcroft-Walton base for R329 photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kato, S.; Shiino, K.; Terada, S.; Kobayashi, N.; Takahashi, K.

    1995-06-01

    A Cockcroft-Walton photomultiplier tube base was constructed for the SDC muon scintillation counters which use a R329 photomultiplier tube (Hamamatsu). We present test results of linearity, load characteristics and power dissipation. The base was verified to be reliable, robust against magnetic field and easily computer controlled. The voltage distribution ratio of the cathode was adopted to be a value of 4:1:1:1:1:1:1:1:1:1:1:1:1. (author).

  17. Light Production in the Double Chooz Photomultiplier Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, E.; Cerrada, M.; Crespo, J. I.; Gil-Botella, I.; Jimenez, S.; Lopez, M.; Novella, P.; Palomares, C.; Santorelli, R.; Verdugo, A.

    2012-09-13

    In this document we present a study of the phenomenon of light emission (called glowing) in the bases of the Hamamatsu R7081MOD-ASSY photomultiplier tubes (PMTs) used in the Double Chooz experiment. The tests have been carried out at the CIEMAT laboratories over a photomultiplier tube of the same model. We have studied the phenomenon making first a characterization of it, and then focusing on the dependence of the rate and the amount of emitted light versus voltage and temperature. In addition, we have looked for the possible existence of an ultraviolet component in the light which would be harmful for the experiment because it could be able to excite the scintillator liquid. Finally, we propose and test a method to reduce the light emission using a cover on the base of the photomultiplier tube.. (Author)

  18. Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

    NARCIS (Netherlands)

    Aprile, E.; et al., [Unknown; Alfonsi, M.; Colijn, A.P.; Decowski, M.P.; Tiseni, A.; Tunnell, C.

    2015-01-01

    The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company

  19. A superconducting supercollider calorimeter photomultiplier tube preamplifier circuit

    International Nuclear Information System (INIS)

    Panescu, D.; Lackey, J.; Robl, P.; Smith, W.H.

    1992-01-01

    This study presents the design of the front end amplifier for a scintillator calorimeter with photomultiplier tube (PMT) readout. The design is based on analytical computations and SPICE simulations, and is checked against tests performed on a prototyped circuit. We were looking to achieve 1) a very low droop within the 4 ns after the integration of the photomultiplier tube (PMT) signal was completed, 2) a very low noise figure for the whole amplifier in a 100 MHz bandwidth, 3) an input impedance optimized for the PMT which is actually used, 4) baseline restoration as quick as possible at the output of the clip amps, 5) no loss of information due to the saturation at intermediary stages (e.g. integrator), and 6) an output driving 100 Ω twisted pair cables, or 50 Ω coaxial cables, in order to transmit the signal to switched capacitor arrays for analog storage. (orig.)

  20. Actively-stabilized photomultiplier tube base for vacuum operation

    International Nuclear Information System (INIS)

    Bryan, M.A; Morris, C.L.; Idzorek, G.C.

    1992-01-01

    An actively stabilized photomultiplier tube (PMT) base design for an Amperex XP-2262B PMT is described. Positive-negative-positive transistors are used as low-impedance current sources to maintain constant voltages on the last three dynodes. This technique results in a highly stable, low-power tube base ideal for use with low-duty-factor beams, such as those found at the Clinton P. Anderson Meson Physics Facility. Furthermore, because of the low power usage of this large design, these bases can be sealed in a heat-conductive, electrically insulating material and used in a vacuum

  1. Upgrading PhotoMultiplier Tube bases for FNAL E1039

    Science.gov (United States)

    Salinas, Roy; SeaQuest Collaboration

    2017-09-01

    Experiment 1039 at Fermilab National Laboratory is designed to study the spin structure within the nucleon. To effectively work towards a better understanding of the ``spin crisis'' concerning the quarks and gluons within the nucleon, E1039 will employ a polarized target and a 120 GeV proton beam. The E906/SeaQuest spectrometer will be reused for E1039 since it was designed to measure Drell-Yan events from interactions with quarks in the nucleon sea. The spectrometer consists of several detectors with multiple planes of scintillating hodoscopes, tracking chambers, and two large dipole magnets. An issue arose in the later stages of Experiment 906 regarding the scintillating PhotoMultiplier Tubes(PMTs) high current bases for the first two hodoscope stations. Heat produced in the PMT bases created damage to components on the primary circuit board resulting in failures after years of running. Multiple solutions focused on thermally connecting the daughter cards to the metal shielding pipe while also providing electrical isolation of the high voltages present. Comparisons of thermally conductive adhesive and epoxy were studied with several heat spreaders. This poster will cover the options considered and the chosen solution to the upgrade to the hodoscope PMT bases. Supported by U.S. D.O.E. Medium Energy Nuclear Physics under Grant DE-FG02-03ER41243.

  2. Characterization of Multianode Photomultiplier Tubes for a Cherenkov Detector

    Science.gov (United States)

    Benninghoff, Morgen; Turisini, Matteo; Kim, Andrey; Benmokhtar, Fatiha; Kubarovsky, Valery; Duquesne University Collaboration; Jefferson Lab Collaboration

    2017-09-01

    In the Fall of 2017, Jefferson Lab's CLAS12 (CEBAF Large Acceptance Spectrometer) detector is expecting the addition of a RICH (ring imaging Cherenkov) detector which will allow enhanced particle identification in the momentum range of 3 to 8 GeV/c. RICH detectors measure the velocity of charged particles through the detection of produced Cherenkov radiation and the reconstruction of the angle of emission. The emitted Cherenkov photons are detected by a triangular-shaped grid of 391 multianode photomultiplier tubes (MAPMTs) made by Hamamatsu. The custom readout electronics consist of MAROC (multianode read out chip) boards controlled by FPGA (Field Programmable Gate Array) boards, and adapters used to connect the MAROC boards and MAPMTs. The focus of this project is the characterization of the MAPMTs with the new front end electronics. To perform these tests, a black box setup with a picosecond diode laser was constructed with low and high voltage supplies. A highly automated procedure was developed to acquire data at different combinations of high voltage values, light intensities and readout electronics settings. Future work involves using the collected data in calibration procedures and analyzing that data to resolve the best location for each MAPMT. SULI, NSF.

  3. Position-sensitive gaseous photomultipliers research and applications

    CERN Document Server

    Francke, Tom; Peskov, Vladimir

    2016-01-01

    Gaseous photomultipliers are defined as gas-filled devices capable of recording single ultraviolet (UV) and visible photons with high position resolution. Used in a variety of research areas, these detectors can be paired with computers to treat and store imaging information of UV-light. Position-Sensitive Gaseous Photomultipliers: Research and Applications explores the advancement of gaseous detectors as applied for single photon detection. Emphasizing emerging perspectives and new ways to apply gaseous detectors across research fields, this research-based publication is an essential reference source for engineers, physicists, graduate-level students, and researchers.

  4. Study of large hemispherical photomultiplier tubes for the ANTARES neutrino telescope

    Science.gov (United States)

    Aguilar, J. A.; Albert, A.; Ameli, F.; Amram, P.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardellier-Desages, F. E.; Aslanides, E.; Aubert, J.-J.; Bailey, D.; Basa, S.; Battaglieri, M.; Becherini, Y.; Bellotti, R.; Beltramelli, J.; Bertin, V.; Billault, M.; Blaes, R.; Blanc, F.; de Botton, N.; Boulesteix, J.; Bouwhuis, M. C.; Brooks, C. B.; Bradbury, S. M.; Bruijn, R.; Brunner, J.; Burgio, G. F.; Cafagna, F.; Calzas, A.; Capone, A.; Caponetto, L.; Carmona, E.; Carr, J.; Cartwright, S. L.; Castorina, E.; Cavasinni, V.; Cecchini, S.; Charvis, P.; Circella, M.; Colnard, C.; Compère, C.; Coniglione, R.; Cooper, S.; Coyle, P.; Cuneo, S.; Damy, G.; van Dantzig, R.; Deschamps, A.; de Marzo, C.; Denans, D.; Destelle, J.-J.; de Vita, R.; Dinkelspiler, B.; Distefano, C.; Drogou, J.-F.; Druillole, F.; Engelen, J.; Ernenwein, J.-P.; Falchini, E.; Favard, S.; Feinstein, F.; Ferry, S.; Festy, D.; Flaminio, V.; Fopma, J.; Fuda, J.-L.; Gallone, J.-M.; Giacomelli, G.; Girard, N.; Goret, P.; Graf, K.; Hallewell, G.; Hartmann, B.; Heijboer, A.; Hello, Y.; Hernández-Rey, J. J.; Herrouin, G.; Hößl, J.; Hoffmann, C.; Hubbard, J. R.; Jaquet, M.; de Jong, M.; Jouvenot, F.; Kappes, A.; Karg, T.; Karkar, S.; Karolak, M.; Katz, U.; Keller, P.; Kooijman, P.; Korolkova, E. V.; Kouchner, A.; Kretschmer, W.; Kuch, S.; Kudryavtsev, V. A.; Lafoux, H.; Lagier, P.; Lahmann, R.; Lamare, P.; Languillat, J.-C.; Laschinsky, H.; Laubier, L.; Legou, T.; Le Guen, Y.; Le Provost, H.; Le van Suu, A.; Lo Nigro, L.; Lo Presti, D.; Loucatos, S.; Louis, F.; Lyashuk, V.; Marcelin, M.; Margiotta, A.; Maron, C.; Massol, A.; Masullo, R.; Mazéas, F.; Mazure, A.; McMillan, J. E.; Migneco, E.; Millot, C.; Milovanovic, A.; Montanet, F.; Montaruli, T.; Morel, J.-P.; Morganti, M.; Moscoso, L.; Musumeci, M.; Naumann, C.; Naumann-Godo, M.; Nezri, E.; Niess, V.; Nooren, G. J.; Ogden, P.; Olivetto, C.; Palanque-Delabrouille, N.; Papaleo, R.; Payre, P.; Petta, C.; Piattelli, P.; Pineau, J.-P.; Poinsignon, J.; Popa, V.; Potheau, R.; Pradier, T.; Racca, C.; Raia, G.; Randazzo, N.; Real, D.; van Rens, B. A. P.; Réthoré, F.; Riccobene, G.; Rigaud, V.; Ripani, M.; Roca-Blay, V.; Rolin, J.-F.; Romita, M.; Rose, H. J.; Rostovtsev, A.; Ruppi, M.; Russo, G. V.; Sacquin, Y.; Salesa, F.; Salomon, K.; Saouter, S.; Sapienza, P.; Shanidze, R.; Schuller, J.-P.; Schuster, W.; Sokalski, I.; Spurio, M.; Stolarczyk, T.; Stubert, D.; Taiuti, M.; Thompson, L. F.; Tilav, S.; Valdy, P.; Valente, V.; Vallage, B.; Vernin, P.; Virieux, J.; de Vries, G.; de Witt Huberts, P.; de Wolf, E.; Zaborov, D.; Zaccone, H.; Zakharov, V.; Zornoza, J. D.; Zúñiga, J.

    2005-12-01

    The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a three-dimensional matrix of 900 large area photomultiplier tubes housed in pressure-resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the photomultiplier tube chosen for ANTARES.

  5. High resolution scintillation hodoscope using a position sensitive photomultiplier

    International Nuclear Information System (INIS)

    Ditta, J.; Sillou, D.; Michalowicz, A.; Azaiez, H.; Kuroda, K.

    1983-09-01

    Using a position sensitive photomultiplier we have realized and tested a prototype of high resolution scintillation hodoscope. A space resolution of approximately 1 mm (FWHM) has been obtained by a single block of NE102A scintillator, 10 mm thick, with 10 GeV/c π - particles. An off-line analysis based on the moment method has confirmed the fact that suitable cuts in the second-order moments provides a powerful criterion for improving the image quality

  6. High Voltage Power Supply With High Output Current and Low Power Consumption for Photomultiplier Tubes

    Science.gov (United States)

    Cunha, José Paulo V. S.; Begalli, Marcia; Bellar, Maria Dias

    2012-04-01

    In some applications, photomultiplier tubes (PMTs) are powered by battery based circuits, where the available energy is severely limited. The most simple approach to design high voltage power supplies (HVPS) for PMTs has considered resistive voltage dividers in order to bias the dynodes. However, this approach usually results in high power losses and, consequently, this undermines the PMT performance. In this work, the proposed solution is the use of a power circuit based on the forward converter connected to a transformer built with several secondary windings. Each secondary voltage is rectified and filtered to eliminate voltage ripple. Each dynode voltage is supplied by a rectified secondary voltage. The proposed topology provides low power consumption as well as low sensitivity of the PMT gain with respect to the dynode currents. Taking into account the Waste Electrical and Electronic Equipment Directive (WEEE), this HVPS has been designed to allow the recycling of old PMTs.

  7. Characterization of photo-multiplier tube as ex-vessel radiation detector in tokamak

    Science.gov (United States)

    Jo, Jungmin; Cheon, MunSeong; Kim, Junghee; An, YoungHwa; Park, Seungil; Chung, Kyoung-Jae; Hwang, Y. S.

    2017-09-01

    Feasibility of using conventional photo-multiplier tubes (PMTs) without a scintillator as an ex-vessel radiation detector in a tokamak environment is studied. Basic irradiation tests using standard gamma ray sources and a d-d neutron generator showed that the PMT is responding both to gamma photons and neutrons, possibly due to the direct generation of secondary electrons inside the PMT by the impingement of high energy photons. Because of the selective sensitivity of the PMT to hard x-ray and neutrons in ohmic and neutral beam injected plasmas, respectively, it is shown that the PMT with certain configuration can be utilized either to monitor the fluctuation in the fusion neutron generation rate or to study the behavior of runaway electrons in tokamaks.

  8. Monte Carlo calculations of the optical coupling between bismuth germanate crystals and photomultiplier tubes

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Riles, J.K.

    1981-10-01

    The high density and atomic number of bismuth germanate (Bi 4 Ge 3 O 12 or BGO) make it a very useful detector for positron emission tomography. Modern tomograph designs use large numbers of small, closely-packed crystals for high spatial resolution and high sensitivity. However, the low light output, the high refractive index (n=2.15), and the need for accurate timing make it important to optimize the transfer of light to the photomultiplier tube (PMT). We describe the results of a Monte Carlo computer program developed to study the effect of crystal shape, reflector type, and the refractive index of the PMT window on coupling efficiency. The program simulates total internal, external, and Fresnel reflection as well as internal absorption and scattering by bubbles

  9. The photomultiplier tube testing facility for the Borexino experiment at LNGS

    Energy Technology Data Exchange (ETDEWEB)

    Brigatti, A. [INFN sez. di Milano, Via Celoria, 16, I-20133 Milan (Italy); Ianni, A. [INFN - Laboratori Nazionali del Gran Sasso, S.S. 17bis Km 18-910, I-67010 Assergi, Aquila (Italy); Lombardi, P. [Dipartimento di Fisica Universita and INFN. sez. di Milano, Via Celoria, 16, I-20133 Milan (Italy); Ranucci, G. [Dipartimento di Fisica Universita and INFN. sez. di Milano, Via Celoria, 16, I-20133 Milan (Italy); Smirnov, O.Ju. [Joint Institute for Nuclear Research, Joliot-Curie, 6, 141980 Dubna (Russian Federation)]. E-mail: smirnov@lngs.infn.it

    2005-02-01

    A facility to test the photomultiplier tubes (PMTs) for the solar neutrino detector Borexino was built at the Gran Sasso laboratory. Using the facility 2200 PMTs with optimal characteristics were selected from the 2350 delivered from the manufacturer. The details of the hardware used are presented.

  10. An efficient high-voltage power supply for a photomultiplier tube

    NARCIS (Netherlands)

    Ainutdinov, VM; Vonsovskii, NN; Kompaniets, KG; Kozyr, AI; Mikhailov, YV

    2003-01-01

    An adjustable power supply for a photomultiplier tube operating in the pulsed spectrometric mode with a wide range of linearity is described. The power consumed by the source is 50 mW. The output voltage is varied from 800 to 2000 V. The maximum ripple amplitude is 2.5 mV.

  11. Evaluation of magnetic defocusing for a photomultiplier tube with large area semitransparent photocathode.

    Science.gov (United States)

    Knight, W; Kohanzadeh, Y; Lengyel, G

    1968-06-01

    Reduction of the effective cathode area of photomultiplier tubes is known to yield lower dark currents and an improved signal-to-noise ratio. This can be accomplished either by electrostatic or magnetic defocusing of the electron beam between the cathode and the first dynode. Three magnetic lenses with different field geometries were tried with an EMI 9558B photomultiplier tube, and a noise reduction of more than an order of magnitude was observed. Magnetic defocusing changes the pulse height characteristies of the tube as well and improves the discrimination between signal pulses and dark pulses when using simple pulse height discrimination techniques. If the tube is operated as a photon counter, the light-to-dark count ratio may be improved by nearly two orders of magnitude with the application of a suitable magnetic lens.

  12. Model independent approach to the single photoelectron calibration of photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Saldanha, R.; Grandi, L.; Guardincerri, Y.; Wester, T.

    2017-08-01

    The accurate calibration of photomultiplier tubes is critical in a wide variety of applications in which it is necessary to know the absolute number of detected photons or precisely determine the resolution of the signal. Conventional calibration methods rely on fitting the photomultiplier response to a low intensity light source with analytical approximations to the single photoelectron distribution, often leading to biased estimates due to the inability to accurately model the full distribution, especially at low charge values. In this paper we present a simple statistical method to extract the relevant single photoelectron calibration parameters without making any assumptions about the underlying single photoelectron distribution. We illustrate the use of this method through the calibration of a Hamamatsu R11410 photomultiplier tube and study the accuracy and precision of the method using Monte Carlo simulations. The method is found to have significantly reduced bias compared to conventional methods and works under a wide range of light intensities, making it suitable for simultaneously calibrating large arrays of photomultiplier tubes.

  13. Dynamic magnetic shield for the CLAS12 central TOF detector photomultiplier tubes

    International Nuclear Information System (INIS)

    The Central Time-of-Flight detector for the Jefferson Laboratory 12-GeV upgrade is being designed with linear-focused photomultiplier tubes that require a robust magnetic shield against the CLAS12 main 5-T solenoid fringe fields of 100 mT (1 kG). Theoretical consideration of a ferromagnetic cylinder in an axial field has demonstrated that its shielding capability decreases with increasing length. This observation has been confirmed with finite element analysis using POISSON model software. Several shields composed of coaxial ferromagnetic cylinders have been studied. All difficulties caused by saturation effects were overcome with a novel dynamical shield, which utilizes a demagnetizing solenoid between the shielding cylinders. Basic dynamical shields for ordinary linear-focused 2-in. photomultiplier tubes were designed and tested both with models and experimental prototypes at different external field and demagnetizing current values. Our shield design reduces the 1 kG external axial field by a factor of 5000.

  14. Multi Anode Photomultiplier Tube Reliability Assessment for the JEM-EUSO Space Mission

    OpenAIRE

    Prieto-Alfonso, H.; del Peral, L.; Casolino, M.; Tsuno, K.; Ebisuzaki, T.; Frías, M. D. Rodríguez; Collaboration, JEM-EUSO

    2015-01-01

    Reliability assessment in concerned with the analysis of devices and systems whose individual components are prone to fail. This reliability analysis documents the process and results of reliability determination of the JEM-EUSO photomultiplier tube component using the methods 217 Plus. Quantum efficiency degradation and radiation hardness assurance. In conclussion, the levels of damage suffered by the PMTs which comprise the focal surface of JEM-EUSO Space Telescope, are acceptable. The resu...

  15. The characterisation of the multianode photomultiplier tubes for the RICH-1 upgrade project at COMPASS

    Science.gov (United States)

    Abbon, P.; Alexeev, M.; Angerer, H.; Birsa, R.; Bordalo, P.; Bradamante, F.; Bressan, A.; Chiosso, M.; Ciliberti, P.; Colantoni, M. L.; Dafni, T.; Dalla Torre, S.; Delagnes, E.; Denisov, O.; Deschamps, H.; Diaz, V.; Dibiase, N.; Duic, V.; Eyrich, W.; Ferrero, A.; Finger, M.; Finger, M.; Fischer, H.; Gerassimov, S.; Giorgi, M.; Gobbo, B.; Hagemann, R.; von Harrach, D.; Heinsius, F. H.; Joosten, R.; Ketzer, B.; Kolosov, V. N.; Königsmann, K.; Konorov, I.; Kramer, D.; Kunne, F.; Lehmann, A.; Levorato, S.; Maggiora, A.; Magnon, A.; Mann, A.; Martin, A.; Menon, G.; Mutter, A.; Nähle, O.; Nerling, F.; Neyret, D.; Panzieri, D.; Paul, S.; Pesaro, G.; Pizzolotto, C.; Polak, J.; Rebourgeard, P.; Robinet, F.; Rocco, E.; Schiavon, P.; Schill, C.; Schoenmeier, P.; Schroeder, W.; Silva, L.; Slunecka, M.; Sozzi, F.; Steiger, L.; Sulc, M.; Svec, M.; Takekawa, S.; Tessarotto, F.; Teufel, A.; Wollny, H.

    2008-09-01

    A major upgrade of the Cherenkov photon detection system of COMPASS RICH-1 has been performed and it has been in operation since the 2006 physics run. The inner part of the photon detector has been replaced by a different technology in order to measure Cherenkov photons at high photoelectron rates, up to several times 10 6 per second and per channel. Cherenkov photons from 200 to 750 nm are detected by 576 multianode photomultiplier tubes (MAPMTs) with 16 channels each, coupled to individual fused silica lens telescopes and fast, high sensitivity and high time resolution electronics read-out. To guarantee an optimal performance of the complete system, parameters like dark current, gain, uniformity, relative quantum efficiency have been measured for a totality of more than 600 MAPMTs (about 10 000 channels) in a fully automated test-stand, developed for this purpose. The ideal working point for each individual pixel could be ascertained by these measurements. In 2006 the newly equipped detector exhibited an excellent performance: about 56 detected photons per ring at saturation and a time resolution of better than 1 ns. We report about the MAPMT characterisation and the quality control set-up, protocol and results.

  16. Properties of 8-inch photomultiplier tubes for a large volume imaging water Cerenkov detector

    International Nuclear Information System (INIS)

    Oehler, Ch.

    1996-01-01

    In the Institut fuer Kernphysik I conceptional studies for a possible succession project for the KARMEN-ν-detector are performed. This design studies propose to build a large volume 1300 t imaging water Cerenkov detector. The main goal of this experiment will be the investigation of ν-e - -scattering in the medium energy range up to 50 MeV. The sensitive surface of this detector will be instrumented with about 3000 8-inch photomultiplier tubes (PMT) providing a coverage of 20%. In the framework of this detector design, studies of the properties of hemispherical 8-inch phototubes have been investigated in this work. The topic was to optimise the quality of the important PMT properties like time- and energy-resolution which are crucial to achieve the required spatial and angular resolutions. A second task of this work was to construct a test facility for the PMT, with the possibility to test large quantities. Monte Carlo calculations show that the required detector resolutions of σ E /E(E e ≤50 MeV)=5.2%+47%/√E, σ t (E e ∼30 MeV)=0.6 ns, σ x (E e ∼30 MeV)=13 cm, σ Θ (E e ∼30 MeV)=20 , can be achieved if the phototubes have a transit-time spread less than 1 ns. Up to now, two different 8-inch tubes are available and have been tested, the HAMAMATSU R5912 and the EMI 9353. (orig.)

  17. Test of multi-anode photomultiplier tubes for the LHCb scintillator pad detector

    CERN Document Server

    Aguiló, Ernest; Comerma-Montells, A; Garrido, Lluis; Gascon, David; Graciani, Ricardo; Grauges, Eugeni; Vilasis Cardona, Xavier; Xirgu, Xavier; Bohner, Gerard; Bonnefoy, Romeo; Borras, David; Cornat, Remi; Crouau, Michel; Deschamps, Olivier; Jacquet, Philippe; Lecoq, Jacques; Monteil, Stephane; Perret, Pascal; Reinmuth, Guy

    2005-01-01

    The LHCb experiment (The LHCb Technical Proposal, CERN/LHCC 98-4) is designed to study B meson physics in the LHC proton-proton collider at CERN. The Scintillator Pad Detector (SPD) has been designed to complete the calorimeter information performing an e/gamma identification for the experiment level-0 trigger system. The detection technology consists in transmitting scintillation light by means of both Wavelength Shifting and clear fibers to fast multi- anode photomultiplier tubes. In this paper, it is described the instrumentation and setup used to characterize the baseline photomultiplier solution (Hamamatsu R5900-00-M64) together with the scintillators and optical fibers for the SPD at LHCb.

  18. Effects of 1- and 2-MeV electrons on photomultiplier tubes

    Science.gov (United States)

    Beatty, M. E., III; Debnam, W. J., Jr.; Meredith, B. D.

    1976-01-01

    Various types of photomultiplier tubes useful for space applications were irradiated with 1- and 2-MeV electrons at Van Allen radiation belt fluxes of 100,000 to 10 millions electrons/sq cm-sec. The increase in the dark current due to electron irradiation was observed at various bias voltages under worst-case conditions (no shielding). Results were presented in the form of dark current plotted against electron flux. All the tubes tested showed extremely large increases in dark current. Tube types 541A, 6217, 6199, and 6903 exhibited the largest increases under irradiation, whereas type 1P22 was affected the least. All the damage observed was transient. The luminescence produced in the optical window probably accounts for a large part of the dark-current increases, but there were some effects possibly due to direct irradiation of the photocathode and dynode chain.

  19. Characterization of a multi-anode photo-multiplier tube for array detectors

    CERN Document Server

    Xu Li Bo; Li Yu Lan; Wang Shao Feng

    2002-01-01

    Two types of Haematomas R5900 series photomultiplier tubes (PMTs) have been evaluated for reading out arrays of small scintillator elements. Both PMTs have metal-channel dynode structures and compact dimensions. H6568 and H6568-10 have the same dimensions of 30 mm x 30 mm x 45 mm and different voltage distribution ratio. The authors report measurements that include gain, single photoelectron spectrum, linearity of anode output signal, cross-talk and gain variation. The characteristics of the MAPMT make it well suited for detection of light from scintillator array

  20. Test of digital neutron–gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)

    Energy Technology Data Exchange (ETDEWEB)

    Luo, X.L., E-mail: luo.xiaoliang@physics.uu.se [Department of Instrument Science and Technology, College of Mechatronics and Automation, National University of Defense Technology, Changsha (China); Department of Physics and Astronomy, Uppsala University, SE-75120 Uppsala (Sweden); Modamio, V. [INFN, Laboratori Nazionali di Legnaro, I-35020 Legnaro, Padova (Italy); Nyberg, J. [Department of Physics and Astronomy, Uppsala University, SE-75120 Uppsala (Sweden); Valiente-Dobón, J.J. [INFN, Laboratori Nazionali di Legnaro, I-35020 Legnaro, Padova (Italy); Nishada, Q. [Department of Physics and Astronomy, Uppsala University, SE-75120 Uppsala (Sweden); Angelis, G. de [INFN, Laboratori Nazionali di Legnaro, I-35020 Legnaro, Padova (Italy); Agramunt, J. [IFIC-CSIC, University of Valencia, Valencia (Spain); Egea, F.J. [IFIC-CSIC, University of Valencia, Valencia (Spain); Faculty of Engineering and Natural Sciences, Istanbul Sabahattin Zaim University, Istanbul (Turkey); Erduran, M.N.; Ertürk, S. [Nigde Universitesi, Fen-Edebiyat Falkültesi, Fizik Bölümü, Nigde (Turkey); France, G. de [GANIL, CEA/DSAM and CNRS/IN2P3, Bd Henri Becquerel, BP 55027, F-14076 Caen Cedex 05 (France); Gadea, A. [IFIC-CSIC, University of Valencia, Valencia (Spain); González, V. [Department of Electronic Engineering, University of Valencia, E-46071 Valencia (Spain); Hüyük, T. [IFIC-CSIC, University of Valencia, Valencia (Spain); Jaworski, G. [Faculty of Physics, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warszawa (Poland); Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, 02-093 Warszawa (Poland); Moszyński, M. [Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, 02-093 Warszawa (Poland); National Centre for Nuclear Research, A. Soltana 7, PL 05-400 Otwock-Swierk (Poland); and others

    2014-12-11

    A comparative study of the neutron–γ discrimination performance of a liquid scintillator detector BC501A coupled to four different 5 in. photomultiplier tubes (ET9390kb, R11833-100, XP4512 and R4144) was carried out. Both the Charge Comparison method and the Integrated Rise-Time method were implemented digitally to discriminate between neutrons and γ rays emitted by a {sup 252}Cf source. In both methods, the neutron–γ discrimination capabilities of the four photomultiplier tubes were quantitatively compared by evaluating their figure-of-merit values at different energy regions between 50 keVee and 1000 keVee. Additionally, the results were further verified qualitatively using time-of-flight to distinguish γ rays and neutrons. The results consistently show that photomultiplier tubes R11833-100 and ET9390kb generally perform best regarding neutron–γ discrimination with only slight differences in figure-of-merit values. This superiority can be explained by their relatively higher photoelectron yield, which indicates that a scintillator detector coupled to a photomultiplier tube with higher photoelectron yield tends to result in better neutron–γ discrimination performance. The results of this work will provide reference for the choice of photomultiplier tubes for future neutron detector arrays like NEDA.

  1. Light yield of an undoped CsI crystal coupled directly to a photomultiplier tube at 77 Kelvin

    International Nuclear Information System (INIS)

    Liu, J.; Soma, A.K.; Yamashita, M.

    2016-01-01

    A light yield of 20.4 ± 0.8 photoelectrons/keV was achieved with an undoped CsI crystal coupled directly to a photomultiplier tube at 77 Kelvin. This is by far the largest yield in the world achieved with CsI crystals. An energy threshold that is several times lower than the current dark matter experiments utilizing CsI(Tl) crystals may be achievable using this technique. Together with novel CsI crystal purification methods, the technique may be used to improve the sensitivities of dark matter and coherent elastic neutrino-nucleus scattering experiments. Also measured were the scintillation light decay constants of the undoped CsI crystal at both room temperature and 77 Kelvin. The results are consistent with those in the literature.

  2. X-ray detection with a scintillating YAP-window hybrid photomultiplier tube

    CERN Document Server

    D'Ambrosio, C; Leutz, H; Puertolas, D; Rosso, E

    2000-01-01

    A YAP(YAlO/sub 3/:Ce)-scintillating window, coated on its inner surface with an S20-photocathode, seals a cross-focusing hybrid photomultiplier tube (HPMT) equipped with a small p-i-n anode of 2-mm diameter. This new radiation detector separates X-ray lines down to about 2-keV peak energy from the HPMT noise. Its detection efficiency for high gamma energies depends on the YAP-window thickness and amounts to about 18% attenuation at 400-keV energy in the present version. Competitive radiation detectors like Si photodiodes and Si drift chambers are discussed and compared to our prototype, with particular attention given to their energy resolution and noise performance, which limits their active area considerably. (19 refs).

  3. Characterization of photomultiplier tubes with a realistic model through GPU-boosted simulation

    Science.gov (United States)

    Anthony, M.; Aprile, E.; Grandi, L.; Lin, Q.; Saldanha, R.

    2018-02-01

    The accurate characterization of a photomultiplier tube (PMT) is crucial in a wide-variety of applications. However, current methods do not give fully accurate representations of the response of a PMT, especially at very low light levels. In this work, we present a new and more realistic model of the response of a PMT, called the cascade model, and use it to characterize two different PMTs at various voltages and light levels. The cascade model is shown to outperform the more common Gaussian model in almost all circumstances and to agree well with a newly introduced model independent approach. The technical and computational challenges of this model are also presented along with the employed solution of developing a robust GPU-based analysis framework for this and other non-analytical models.

  4. A Near-Infrared Optical Tomography System Based on Photomultiplier Tube

    Directory of Open Access Journals (Sweden)

    Huacheng Feng

    2007-01-01

    Full Text Available Diffuse optical tomography (DOT is a rapidly growing discipline in recent years. It plays an important role in many fields, such as detecting breast cancer and monitoring the cerebra oxygenation. In this paper, a relatively simple, inexpensive, and conveniently used DOT system is presented in detail, in which only one photomultiplier tube is employed as the detector and an optical multiplexer is used to alter the detector channels. The 32-channel imager is consisted of 16-launch fibers and 16-detector fibers bundles, which works in the near-infrared (NIR spectral range under continuous-wave (CW model. The entire imaging system can work highly automatically and harmoniously. Experiments based on the proposed imaging system were performed, and the desired results can be obtained. The experimental results suggested that the proposed imaging instrumentation is effective.

  5. Evaluation of candidate photomultiplier tubes for the upgrade of the CDF end plug calorimeter

    International Nuclear Information System (INIS)

    Koska, W.; Delchamps, S.W.; Freeman, J.; Kinney, W.; Lewis, D.; Limon, P.; Strait, J.; Fiori, I.; Gallinaro, M.; Shen, Q.

    1994-01-01

    The Collider Detector at Fermilab is upgrading its end plug calorimeter from a gas detector system to one using scintillating tiles and wavelength shifting fibers. This tile-fiber calorimeter will be read out through 1,824 photomultiplier tubes. The performance requirements of the calorimeter require that the PMTs have good response to light in the 500 nm region, provide adequate amplification for signals from minimum ionizing particles yet provide linear response for peak anode currents up to 25 mA at a gain of 50,000, and fit into the restricted space at the rear of the plugs. This paper will describe the evaluation process used to determine the adequacy of the commercially available PMTs which appeared to meet these performance requirements

  6. Time fluctuations in the response of photomultiplier tubes Dario 56 AVP, XP 1021, XP 1210

    International Nuclear Information System (INIS)

    Breuze, G.; Sawine, P.

    1969-01-01

    The authors have studied experimentally the intrinsic time resolving power of 3 photomultiplier tubes, Dario 56 AVP, XP 1021, XP 1210 at various excitation levels produced by a source of short light pulses. They show, in agreement with present theories, that there exists an optimal resolving power for a certain trigger threshold, and they check the law governing the variations of this resolving power with the average number of photo-electrons emitted by light pulse, up to the limiting case of a single photo-electron. The results obtained show the progress which has been made by the constructor between the 56 AVP and the XP 1210 models: for 100 photo-electrons per pulse, for example, the times of resolution are 260 x 10 -12 s and 75 x 10 -12 s respectively; whereas the rise time for the anode pulses decreases from 2,3 to 1,2 x 10 -9 s. The intermediate tube XP 1021 has also a particularly good performance with respect to the 56 AVP, which it resembles very much both in its price and by its outer aspect. The authors stress finally the difficulties encountered in measuring with accuracy the time characteristics of PM as fast as the XP 1210, and in particular the limitation imposed by the light source. (author) [fr

  7. A useful method to monitor outputs from a pulsed light source and its application to rate effect studies in a photomultiplier tube

    CERN Document Server

    Takeuchi, Y; Kurashige, H; Matono, Y; Murakami, K; Nomura, T; Sakamoto, H; Sasao, N; Suehiro, M; Fukushima, Y; Ikegami, Y; Nakamura, T T; Taniguchi, T; Asai, M

    1999-01-01

    In order to study short-term gain stability in a photomultiplier tube at high counting rate, we constructed an LED pulsed light source and its output monitoring system. For the monitoring system, we employed a photon counting method using a photomultiplier as a monitor photon detector. It is found that the method offers a simple way to monitor outputs from a pulsed light source and that, together with an LED light source, it provides a useful method to investigate photomultiplier's rate effects.

  8. Replacement of a photomultiplier tube in a 2-inch thallium-doped sodium iodide gamma spectrometer with silicon photomultipliers and a light guide

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Kyu; Kim, Hyoung Taek; Kim, Jong Yul [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); and others

    2015-06-15

    The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) 2′ X 2′ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

  9. Replacement of a photomultiplier tube in a 2-inch thallium-doped sodium iodide gamma spectrometer with silicon photomultipliers and a light guide

    Directory of Open Access Journals (Sweden)

    Chankyu Kim

    2015-06-01

    Full Text Available The thallium-doped sodium iodide [NaI(Tl] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs. It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl 2′ × 2′ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

  10. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Qin, Hong [School of Computer Science and Technology, Xi' an University of Science and Technology, Xi' an 710054 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China)

    2017-04-11

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  11. Extension of photomultiplier tube dynamic range for the LHAASO-KM2A electromagnetic particle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Hongkui, E-mail: lvhk@ihep.ac.cn [Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Sheng, Xiangdong; He, Huihai; Liu, Jia [Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhang, Zhongquan [Shandong University, Jinan 250100 (China); Hou, Chao; Zhao, Jing [Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-05-01

    In the Large High Altitude Air Shower Observatory (LHAASO), the 1 km{sup 2} array (KM2A) requires linear measurement of optical intensity with a wide dynamic range. Over 5000 photomultiplier tubes (PMTs) are employed in this experiment and developed as “two outputs” device (anode and dynode) to meet the relevant requirements. In this study, the linearity of the anode and the eighth dynode (DY8), which is limited by space charge effects and mainly related to the relative dynode voltage ratios of the PMT divider, is examined. A voltage divider for the Hamamatsu R11102 PMT is designed and a dramatically enhanced linearity is demonstrated. Test results show that this design can cover a wide dynamic range from 20 to 2×10{sup 5} photoelectrons and achieve a peak anode current of 380 mA at a PMT gain of 10{sup 5}, which satisfies the requirements of KM2A electromagnetic particle detectors. The circuit design has been successfully simulated using the simulation software Multisim. The details of PMT performance tests and simulations are described.

  12. Extension of photomultiplier tube dynamic range for the LHAASO-KM2A electromagnetic particle detectors

    Science.gov (United States)

    Lv, Hongkui; Sheng, Xiangdong; He, Huihai; Liu, Jia; Zhang, Zhongquan; Hou, Chao; Zhao, Jing

    2015-05-01

    In the Large High Altitude Air Shower Observatory (LHAASO), the 1 km2 array (KM2A) requires linear measurement of optical intensity with a wide dynamic range. Over 5000 photomultiplier tubes (PMTs) are employed in this experiment and developed as "two outputs" device (anode and dynode) to meet the relevant requirements. In this study, the linearity of the anode and the eighth dynode (DY8), which is limited by space charge effects and mainly related to the relative dynode voltage ratios of the PMT divider, is examined. A voltage divider for the Hamamatsu R11102 PMT is designed and a dramatically enhanced linearity is demonstrated. Test results show that this design can cover a wide dynamic range from 20 to 2×105 photoelectrons and achieve a peak anode current of 380 mA at a PMT gain of 105, which satisfies the requirements of KM2A electromagnetic particle detectors. The circuit design has been successfully simulated using the simulation software Multisim. The details of PMT performance tests and simulations are described.

  13. Extension of photomultiplier tube dynamic range for the LHAASO-KM2A electromagnetic particle detectors

    International Nuclear Information System (INIS)

    Lv, Hongkui; Sheng, Xiangdong; He, Huihai; Liu, Jia; Zhang, Zhongquan; Hou, Chao; Zhao, Jing

    2015-01-01

    In the Large High Altitude Air Shower Observatory (LHAASO), the 1 km 2 array (KM2A) requires linear measurement of optical intensity with a wide dynamic range. Over 5000 photomultiplier tubes (PMTs) are employed in this experiment and developed as “two outputs” device (anode and dynode) to meet the relevant requirements. In this study, the linearity of the anode and the eighth dynode (DY8), which is limited by space charge effects and mainly related to the relative dynode voltage ratios of the PMT divider, is examined. A voltage divider for the Hamamatsu R11102 PMT is designed and a dramatically enhanced linearity is demonstrated. Test results show that this design can cover a wide dynamic range from 20 to 2×10 5 photoelectrons and achieve a peak anode current of 380 mA at a PMT gain of 10 5 , which satisfies the requirements of KM2A electromagnetic particle detectors. The circuit design has been successfully simulated using the simulation software Multisim. The details of PMT performance tests and simulations are described

  14. Performance of a C4F8O gas radiator ring imaging Cherenkov detector using multi-anode photomultiplier tubes

    International Nuclear Information System (INIS)

    Artuso, M.; Boulahouache, C.; Blusk, S.; Butt, J.; Dorjkhaidav, O.; Menaa, N.; Mountain, R.; Muramatsu, H.; Nandakumar, R.; Randrianarivony, K.; Sia, R.; Skwarnicki, T.; Stone, S.; Wang, J.C.; Zhang, K.

    2006-01-01

    We report on tests of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3-m-long gaseous C 4 F 8 O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes. This system was developed to identify charged particles in the momentum range from 3 to 70GeV/c for the BTeV experiment

  15. A novel compensation method for the anode gain non-uniformity of multi-anode photomultiplier tubes.

    Science.gov (United States)

    Lee, Chan Mi; Il Kwon, Sun; Ko, Guen Bae; Ito, Mikiko; Yoon, Hyun Suk; Lee, Dong Soo; Hong, Seong Jong; Lee, Jae Sung

    2012-01-07

    The position-sensitive multi-anode photomultiplier tube (MA-PMT) is widely used in high-resolution scintillation detectors. However, the anode gain nonuniformity of this device is a limiting factor that degrades the intrinsic performance of the detector module. The aim of this work was to develop a gain compensation method for the MA-PMT and evaluate the resulting enhancement in the performance of the detector. The method employs a circuit that is composed only of resistors and is placed between the MA-PMT and a resistive charge division network (RCN) used for position encoding. The goal of the circuit is to divide the output current from each anode, so the same current flows into the RCN regardless of the anode gain. The current division is controlled by the combination of a fixed-value series resistor with an output impedance that is much larger than the input impedance of the RCN, and a parallel resistor, which detours part of the current to ground. PSpice simulations of the compensation circuit and the RCN were performed to determine optimal values for the compensation resistors when used with Hamamatsu H8500 MAPMTs. The intrinsic characteristics of a detector module consisting of this MA-PMT and a lutetium-gadolinium-oxyorthosilicate (LGSO) crystal array were tested with and without the gain compensation method. In simulation, the average coefficient of variation and max/min ratio decreased from 15.7% to 2.7% and 2.0 to 1.2, respectively. In the flood map of the LGSO-H8500 detector, the uniformity of the photopeak position for individual crystals and the energy resolution were much improved. The feasibility of the method was shown by applying it to an octagonal prototype positron emission tomography scanner.

  16. Studies of relative gain and timing response of fine-mesh photomultiplier tubes in high magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Sulkosky, V.; Allison, L.; Barber, C.; Cao, T.; Ilieva, Y.; Jin, K.; Kalicy, G.; Park, K.; Ton, N.; Zheng, X.

    2016-08-01

    We investigated the use of Hamamatsu fine-mesh photomultiplier tube assemblies H6152-70 and H6614-70 with regards to their gain and timing resolution in magnetic fields up to 1.9 T. Our results show that the H6614-70 assembly can operate reliably in magnetic fields exceeding 1.5 T, while preserving a reasonable timing resolution even with a gain reduction of a factor of ~100. The reduction of the relative gain of the H6152-70 is similar to the H6614-70's near 1.5 T, but its timing resolution worsens considerably at this high field.

  17. Design and testing of a magnetic shield for the Thomson scattering photomultiplier tubes in the stray fields of the ERASMUS tokamak

    International Nuclear Information System (INIS)

    Desoppere, E.; Van Oost, G.

    1983-01-01

    A multiple coaxial shield system has been designed for the photomultiplier tubes of the ERASMUS tokamak Thomson scattering diagnostic. A stray field of 75 x 10 -4 T was reduced to 0.01 x 10 -4 T for a field parallel to the tube axis, and to 0.03 x 10 -4 T for a perpendicular field

  18. Ultrafast readout of scintillating fibers using upgraded position-sensitive photomultipliers

    International Nuclear Information System (INIS)

    Onel, Y.

    1994-01-01

    Experimental results obtained with commercially available position-sensitive photomultipliers (PSPM) coupled with 0.5 mm diameter scintillating fiber arrays show some promising performances such as space resolution better than 200 μm and time resolution ∼ 1.5 ns with a detection efficiency higher than 90%. Major progress has also been recently achieved with an upgrade of a PSPM based on new grid dynode structures. Two-track spatial resolution has been studied using the upgraded PSPM. Initial studies demonstrate that two tracks separated by a minimum distance of 3 mm are resolved

  19. Ultrafast Readout of Scintillating Fibres Using Upgraded Position-Sensitive Photomultipliers

    CERN Multimedia

    2002-01-01

    % RD-17 \\\\ \\\\To design a high rate topological trigger device for the future DIRAC Experiment at CERN an extensive work is in progress on a scintillating-fibre detector using a position-sensitive photomultiplier. Several detector prototypes with different lengths ($<$~50~cm) of sensitive area have been tested at T7S~PS beam. \\\\ \\\\With 0.5~mm diameter fibres a spatial resolution of $\\sim$125~$\\mu$m was obtained with a detection efficiency higher than 95\\%. The time resolution is $\\sim$600~ps, and the track position is properly digitized in real time (about 10~ns) by multi-channel peak sensing circuit. Based on experimental data simulations were also performed a comparison of different types of front-end electronics for multi-channel readout.

  20. A model for the Global Quantum Efficiency for a TPB-based wavelength-shifting system used with photomultiplier tubes in liquid argon in MicroBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Pate, S. F. [New Mexico State U.; Wester, T. [MIT, Cambridge, Dept. Phys.; Bugel, L. [MIT, Cambridge, Dept. Phys.; Conrad, J. [MIT, Cambridge, Dept. Phys.; Henderson, E. [New Mexico State U.; Jones, B. J.P. [Texas U., Arlington; McLean, A. I.L. [New Mexico State U.; Moon, J. S. [MIT, Cambridge, Dept. Phys.; Toups, M. [Fermilab; Wongjirad, T. [MIT, Cambridge, Dept. Phys.

    2018-02-28

    We present a model for the Global Quantum Efficiency (GQE) of the MicroBooNE optical units. An optical unit consists of a flat, circular acrylic plate, coated with tetraphenyl butadiene (TPB), positioned near the photocathode of a 20.2-cm diameter photomultiplier tube. The plate converts the ultra-violet scintillation photons from liquid argon into visible-spectrum photons to which the cryogenic phototubes are sensitive. The GQE is the convolution of the efficiency of the plates that convert the 128 nm scintillation light from liquid argon to visible light, the efficiency of the shifted light to reach the photocathode, and the efficiency of the cryogenic photomultiplier tube. We develop a GEANT4-based model of the optical unit, based on first principles, and obtain the range of probable values for the expected number of detected photoelectrons ($N_{\\rm PE}$) given the known systematic errors on the simulation parameters. We compare results from four measurements of the $N_{\\rm PE}$ determined using alpha-particle sources placed at two distances from a TPB-coated plate in a liquid argon cryostat test stand. We also directly measured the radial dependence of the quantum efficiency, and find that this has the same shape as predicted by our model. Our model results in a GQE of $0.0055\\pm0.0009$ for the MicroBooNE optical units. While the information shown here is MicroBooNE specific, the approach to the model and the collection of simulation parameters will be widely applicable to many liquid-argon-based light collection systems.

  1. A model for the Global Quantum Efficiency for a TPB-based wavelength-shifting system used with photomultiplier tubes in liquid argon in MicroBooNE

    Science.gov (United States)

    Pate, S. F.; Wester, T.; Bugel, L.; Conrad, J.; Henderson, E.; Jones, B. J. P.; McLean, A. I. L.; Moon, J. S.; Toups, M.; Wongjirad, T.

    2018-02-01

    We present a model for the Global Quantum Efficiency (GQE) of the MicroBooNE optical units. An optical unit consists of a flat, circular acrylic plate, coated with tetraphenyl butadiene (TPB), positioned near the photocathode of a 20.2-cm diameter photomultiplier tube. The plate converts the ultra-violet scintillation photons from liquid argon into visible-spectrum photons to which the cryogenic phototubes are sensitive. The GQE is the convolution of the efficiency of the plates that convert the 128 nm scintillation light from liquid argon to visible light, the efficiency of the shifted light to reach the photocathode, and the efficiency of the cryogenic photomultiplier tube. We develop a GEANT4-based model of the optical unit, based on first principles, and obtain the range of probable values for the expected number of detected photoelectrons (NPE) given the known systematic errors on the simulation parameters. We compare results from four measurements of the NPE determined using alpha-particle sources placed at two distances from a TPB-coated plate in a liquid argon cryostat test stand. We also directly measured the radial dependence of the quantum efficiency, and find that this has the same shape as predicted by our model. Our model results in a GQE of 0.0055±0.0009 for the MicroBooNE optical units. While the information shown here is MicroBooNE specific, the approach to the model and the collection of simulation parameters will be widely applicable to many liquid-argon-based light collection systems.

  2. LHCb: Characterisation and magnetic field properties of Multianode Photomultiplier tubes for the use in LHCb Upgrade RICH detectors

    CERN Multimedia

    Eisenhardt, S; Morris, A; Needham, M; Neill, J

    2013-01-01

    A key feature of the LHCb upgrade, scheduled for 2019, is to remove the first level trigger and its data reduction from 40MHz to 1MHz, which is implemented in the on-detector readout electronics. The consequence for the LHCb Ring Imaging Cherenkov (RICH) detectors is that the Hybrid Photon Detectors need to be replaced as the readout chip is embedded in the tubes. Baseline for replacement are Multianode Photomultiplier tubes (MaPMT) and new readout electronics. Here we report about characterisation studies of the model Hamamatsu R11265 in the effort to qualify them for use in the LHCb RICH upgrade. Comparisons to the known model R7600 are also made. Two types of readout electronics are used. Most measurements to characterise the properties of the MaPMTs are taken with a VME based reference readout, using a x100 linear amplification and the CAEN V792 12-bit charge integrating digitiser. This allows to derive the signal properties from fits to the single photon spectra. In addition a prototype readout using the...

  3. Integrating printed microfluidics with silicon photomultipliers for miniaturised and highly sensitive ATP bioluminescence detection.

    Science.gov (United States)

    Santangelo, M F; Libertino, S; Turner, A P F; Filippini, D; Mak, W C

    2018-01-15

    Bioluminescence has been widely used for important biosensing applications such as the measurement of adenosine triphosphate (ATP), the energy unit in biological systems and an indicator of vital processes. The current technology for detection is mainly based on large equipment such as readers and imaging systems, which require intensive and time-consuming procedures. A miniaturised bioluminescence sensing system, which would allow sensitive and continuous monitoring of ATP, with an integrated and low-cost disposable microfluidic chamber for handling of biological samples, is highly desirable. Here, we report the design, fabrication and testing of 3D printed microfluidics chips coupled with silicon photomultipliers (SiPMs) for high sensitive real-time ATP detection. The 3D microfluidic chip reduces reactant consumption and facilitates solution delivery close to the SiPM to increase the detection efficiency. Our system detects ATP with a limit of detection (LoD) of 8nM and an analytical dynamic range between 15nM and 1µM, showing a stability error of 3%, and a reproducibility error below of 20%. We demonstrate the dynamic monitoring of ATP in a continuous-flow system exhibiting a fast response time, ~4s, and a full recovery to the baseline level within 17s. Moreover, the SiPM-based bioluminescence sensing system shows a similar analytical dynamic range for ATP detection to that of a full-size PerkinElmer laboratory luminescence reader. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Tube to tube excursive instability - sensitivities and transients

    International Nuclear Information System (INIS)

    Brown, M.; Layland, M.W.

    1980-01-01

    A simple basic analysis of excursive instability in a boiler tube shows how it depends upon operating conditions and physical properties. A detailed mathematical model of an AGR boiler is used to conduct a steady state parameter sensitivity survey. It is possible from this basis to anticipate the effects of changes in operating conditions and changes in design parameters upon tube to tube stability. Dynamic responses of tubes operating near the stability threshold are examined using a mathematical model. Simulated excursions are triggered by imparting small abrupt pressure changes on the boiler inlet pressure. The influences of the magnitude of the pressure change, waterside friction factor and gas side coupling between tubes are examined. (author)

  5. Fast tracking detector with fiber scintillators and a position sensitive photomultiplier

    International Nuclear Information System (INIS)

    Salomon, M.; Li, V.; Smith, G.; Wu, Y.S.

    1988-11-01

    We have studied the properties of a tracking detector composed of 32 fiber scintillators coupled to a multianode photomultiplier placed in a pion beam at TRIUMF. We measured the efficiency of the detector, as well as its tracking capabilities and double hit resolution

  6. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto

    1997-01-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  7. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1997-10-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  8. The photomultiplier handbook

    CERN Document Server

    Wright, A G

    2017-01-01

    Photomultipliers are extremely sensitive light detectors that can detect single photons. In multiplying the charge produced by incident light by up to 100 million times, these devices are essential to a wide range of functions, from medical instrumentation to astronomical observations. This complete and authoritative guide will provide students, practitioners, and researchers with a deeper understanding of the operating principles of these devices. Authored by an experienced user and manufacturer of photomultipliers, this handbook gives the reader insights into photomultiplier behaviour as a means to optimize performance. Diffuse and low level light sources are best served with a photomultiplier for the detection of single photon emissions. Light detection and electron multiplication are statistical in nature and the mathematics of these processes is derived from first principles. The book covers other related topics such as scintillation counting, light guides, and large area detectors. The usually complicat...

  9. X-ray sensitive image intensifier tubes

    International Nuclear Information System (INIS)

    Wang, S.-H.; Robbins, C.D.

    1979-01-01

    In this patent, X-ray sensitive image intensifier tubes which provide multi-stage light amplification between a flat scintillator screen and the output display screen are described. A first amplification stage is constituted by a first photocathode and an intermediate display screen. A second amplification stage comprises a fibreoptic plate, a second photocathode and the output display screen. Accelerating electrostatic potentials are applied respectively between the first display screen and the first photocathode and between the second photocathode and the output display screen. Three or more amplification stages may be used. (author)

  10. Brachytherapy dosimeter with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Moutinho, L.M., E-mail: moutinho@ua.pt [i3N, Physics Department, University of Aveiro (Portugal); Castro, I.F.C. [i3N, Physics Department, University of Aveiro (Portugal); Peralta, L. [Faculdade de Ciências da Universidade de Lisboa (Portugal); Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Lisboa (Portugal); Abreu, M.C. [Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Lisboa (Portugal); Veloso, J.F.C.A. [i3N, Physics Department, University of Aveiro (Portugal)

    2015-07-01

    In-vivo and in-situ measurement of the radiation dose administered during brachytherapy faces several technical challenges, requiring a very compact, tissue-equivalent, linear and highly sensitive dosimeter, particularly in low-dose rate brachytherapy procedures, which use radioactive seeds with low energy and low dose deposition rate. In this work we present a scintillating optical fiber dosimeter composed of a flexible sensitive probe and a dedicated electronic readout system based on silicon photomultiplier photodetection, capable of operating both in pulse and current modes. The performance of the scintillating fiber optic dosimeter was evaluated in low energy regimes, using an X-ray tube operating at voltages of 40–50 kV and currents below 1 mA, to assess minimum dose response of the scintillating fiber. The dosimeter shows a linear response with dose and is capable of detecting mGy dose variations like an ionization chamber. Besides fulfilling all the requirements for a dosimeter in brachytherapy, the high sensitivity of this device makes it a suitable candidate for application in low-dose rate brachytherapy. According to Peralta and Rego [1], the BCF-10 and BCF-60 scintillating optical fibers used in dosimetry exhibit high variations in their sensitivity for photon beams in the 25–100 kVp energy range. Energy linearity for energies below 50 keV needs to be further investigated, using monochromatic X-ray photons.

  11. Development of gaseous photomultiplier

    International Nuclear Information System (INIS)

    Tokanai, F.; Sumiyoshi, T.; Sugiyama, H.; Okada, T.

    2014-01-01

    We have been developing gaseous photomultiplier tubes (PMTs) with alkali photocathode combined with micropattern gas detectors (MPGDs). The potential advantage of the gaseous PMT is that it can achieve a very large effective area with adequate position and timing resolutions. In addition, it will be easily operated under a very high magnetic field, compared with the conventional vacuum-based PMT. To evaluate the gaseous PMTs filled with Ne and Ar based gas mixture, we have developed gaseous PMTs with an alkali photocathode combined with MPGDs such as a glass capillary plate, GEM, and Micromegas detector. We describe the recent development of the gaseous PMTs, particularly the production of the photocathode, gas gain, ion and photon feedbacks, quantum efficiency, and the characteristics in the magnetic field environment. (author)

  12. Timing coincidence studies with fast photomultipliers

    International Nuclear Information System (INIS)

    Raoof, M.A.; Raoof, S.A.

    1981-01-01

    The time response of RCA C70045D photomultipliers was studied using a subnanosecond light flasher. The tubes, which have an output rise time of approximately 0.5 ns, were used in coincidence to study the variations in the fwhm of the time spectrum over a certain dynamic range of pulse amplitudes for both leading edge and constant fraction discrimination. A comparison has also been made for the measured time resolutions with some of the other fast photomultipliers. (orig.)

  13. Pressure effect on the sensitivity of quartz Bourdon tube gauges.

    Science.gov (United States)

    Szaniszlo, A. J.

    1972-01-01

    The sensitivity change for a commercial fused quartz Bourdon tube precision pressure gauge, due to a change in absolute pressure level, has been analytically computed and experimentally confirmed. The computed differential pressure error is 2.5% of full scale at a 100 atm absolute pressure level. The experimental method compared the fused quartz Bourdon tube gauge digital output to the results obtained from a nitrogen gas pressure system which had a high pressure, well-type mercury manometer as the differential pressure reference.

  14. Behaviour of an irradiated photomultiplier

    International Nuclear Information System (INIS)

    Verdant, R.

    1967-04-01

    With the aim of using scintillation detectors for the starting-up, the study of transient phenomena, the control or the safety of a nuclear reactor or of a critical assembly, the behaviour of 8 photomultipliers (Radiotechnique 51 AVP and UVP, and EMI 9524 B) has been studied in the gamma flux of 1 to 10 3 Rh -1 in a storage well, and in an EL 2 reactor channel where the exposures varied between 1 to 2 x 10 3 Rh -1 and 6 x 10 5 to 5 x 10 7 n.cm -2 .s -1 . Spurious pulses are produced by this radiation at the photomultiplier anode. By comparing the amplitudes of these pulses to those produced by a NaI scintillator, it was observed that their maximum energy level was about 100 keV at 10 3 Rh -1 in the gamma flow of the storage well and from 200 to 400 keV at 10 3 Rh -1 and 10 7 n.cm -2 .s -1 in the reactor channel. Furthermore, the detection of a luminous reference pulse corresponding to 200 keV (NaI) is only perturbed at values Of above a few hundred Rh -1 the γ radiation alone, and above 5 x 10 6 n.cm -2 .s -1 and ∼ 500 Rh -1 in the reactor channel. The dispersion of these results is of the order of 2 for the 8 tubes tested. The main part of the γ radiation effect is attributed to the Cerenkov effect in the window of the photomultiplier. The possibility of separating the respective effects of neutrons and of γ radiation is considered. No marked evolution in the photomultiplier parameters during exposure was noticed. Their characteristics were not modified by the doses received, the largest of which attained 4 x 10 12 neutrons.cm -2 and ≅ 3 x 10 4 roentgens. The advantages of using photomultipliers and fast circuits for widening the field of use of photomultipliers under irradiation is stressed. (author) [fr

  15. Characterization of New-Generation Silicon Photomultipliers for Nuclear Security Applications

    Directory of Open Access Journals (Sweden)

    Wonders Marc A.

    2018-01-01

    Full Text Available Silicon photomultipliers have received a great deal of interest recently for use in applications spanning a wide variety of fields, including nuclear safeguards and nonproliferation. For nuclear-related applications, the ability of silicon photomultipliers to discriminate neutrons from gamma rays using pulse shape discrimination when coupled with certain organic scintillators is a characteristic of utmost importance. This work reports on progress characterizing the performance of twenty different silicon photomultipliers from five manufacturers with an emphasis on pulse shape discrimination performance and timing. Results are presented on pulse shape discrimination performance as a function of overvoltage for 6-mm x 6-mm silicon photomultipliers, and the time response to stilbene is characterized for silicon photomultipliers of three different sizes. Finally, comparison with a photomultiplier tube shows that some new-generation silicon photomultipliers can perform as well as photomultiplier tubes in neutron-gamma ray discrimination.

  16. Characterization of New-Generation Silicon Photomultipliers for Nuclear Security Applications

    Science.gov (United States)

    Wonders, Marc A.; Chichester, David L.; Flaska, Marek

    2018-01-01

    Silicon photomultipliers have received a great deal of interest recently for use in applications spanning a wide variety of fields, including nuclear safeguards and nonproliferation. For nuclear-related applications, the ability of silicon photomultipliers to discriminate neutrons from gamma rays using pulse shape discrimination when coupled with certain organic scintillators is a characteristic of utmost importance. This work reports on progress characterizing the performance of twenty different silicon photomultipliers from five manufacturers with an emphasis on pulse shape discrimination performance and timing. Results are presented on pulse shape discrimination performance as a function of overvoltage for 6-mm x 6-mm silicon photomultipliers, and the time response to stilbene is characterized for silicon photomultipliers of three different sizes. Finally, comparison with a photomultiplier tube shows that some new-generation silicon photomultipliers can perform as well as photomultiplier tubes in neutron-gamma ray discrimination.

  17. MRI compatibility of position-sensitive photomultiplier depth-of-interaction PET detectors modules for in-line multimodality preclinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Vaquero, J.J., E-mail: juanjose.vaquero@uc3m.es [Universidad Carlos III de Madrid, Departamento de Bioingeniería e Ingeniería Aeroespacial, Avda. de la Universidad 30 Leganés, 28911 Madrid (Spain); Instituto de Investigación Sanitaria Gregorio Marañón, Madrid (Spain); Sánchez, J.J. [Instituto de Investigación Sanitaria Gregorio Marañón, Madrid (Spain); Udías, J.M.; Cal-González, J. [Grupo de Física Nuclear, Departamento de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Madrid (Spain); Desco, M. [Universidad Carlos III de Madrid, Departamento de Bioingeniería e Ingeniería Aeroespacial, Avda. de la Universidad 30 Leganés, 28911 Madrid (Spain); Instituto de Investigación Sanitaria Gregorio Marañón, Madrid (Spain)

    2013-02-21

    This work addresses the feasibility of a small-animal, in-line PET/MR system based on Position-Sensitive Photo Multiplier Tubes (PS-PMTs). To this end, we measured the effects of static magnetic fields on the PS-PMTs performance in order to explore the minimal tandem separation between the PET and MR subsystems to preserve their respective performances. We concluded that it is possible to achieve minimal degradation of the PET scanner performance (after a system recalibration) if the magnetic field strength influencing the PET detectors is less than 1 mT and if it is oriented perpendicularly to the longitudinal axis of the tube. Therefore, we predict that it will be possible to maintain the PET image quality if it is placed outside the 1 mT line.

  18. Silicon Photomultiplier Performance in High ELectric Field

    Science.gov (United States)

    Montoya, J.; Morad, J.

    2016-12-01

    Roughly 27% of the universe is thought to be composed of dark matter. The Large Underground Xenon (LUX) relies on the emission of light from xenon atoms after a collision with a dark matter particle. After a particle interaction in the detector, two things can happen: the xenon will emit light and charge. The charge (electrons), in the liquid xenon needs to be pulled into the gas section so that it can interact with gas and emit light. This allows LUX to convert a single electron into many photons. This is done by applying a high voltage across the liquid and gas regions, effectively ripping electrons out of the liquid xenon and into the gas. The current device used to detect photons is the photomultiplier tube (PMT). These devices are large and costly. In recent years, a new technology that is capable of detecting single photons has emerged, the silicon photomultiplier (SiPM). These devices are cheaper and smaller than PMTs. Their performance in a high electric fields, such as those found in LUX, are unknown. It is possible that a large electric field could introduce noise on the SiPM signal, drowning the single photon detection capability. My hypothesis is that SiPMs will not observe a significant increase is noise at an electric field of roughly 10kV/cm (an electric field within the range used in detectors like LUX). I plan to test this hypothesis by first rotating the SiPMs with no applied electric field between two metal plates roughly 2 cm apart, providing a control data set. Then using the same angles test the dark counts with the constant electric field applied. Possibly the most important aspect of LUX, is the photon detector because it's what detects the signals. Dark matter is detected in the experiment by looking at the ratio of photons to electrons emitted for a given interaction in the detector. Interactions with a low electron to photon ratio are more like to be dark matter events than those with a high electron to photon ratio. The ability to

  19. Photomultiplier tube artifacts on 67Ga-citrate imaging caused by loss of correction floods due to an off-peak status of one head of a dual-head γ-camera.

    Science.gov (United States)

    Glaser, Joseph E; Song, Na; Jaini, Sridivya; Lorenzo, Ruth; Love, Charito

    2012-12-01

    γ-cameras use flood-field corrections to ensure image uniformity during clinical imaging. A loss or corruption of the correction data of one head of a dual-head camera can result in an off-peak artifactual appearance. We present our experience with the occurrence of such an incident on a (67)Ga scan. A patient was referred for a whole-body (67)Ga scan to evaluate for causes of neutropenic fever. Whole-body planar and static images of the head, chest, abdomen, pelvis, and lower extremities in multiple projections were obtained. Whole-body images showed decreased image quality on the anterior view obtained with detector 1 and an unremarkable posterior image obtained with detector 2. A problem with detector 2 was suspected, and additional static images were obtained after rotation of the detector heads. The posterior images taken with detector 1 showed photomultiplier tube outlines. The anterior images taken with detector 2 showed improved count and image quality. It was later found that the uniformity map for detector 2 had been lost and that this software malfunction led to the resulting imaging problem. When artifacts with an off-peak appearance are seen on scintigraphic images, evaluation of possible causes should include not only isotope window settings but also an incorrect or corrupted uniformity map.

  20. Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers

    Science.gov (United States)

    Ren, Ming; Song, Bo; Dong, Ming

    2017-01-01

    Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring. PMID:29125544

  1. Silicon Photomultipliers for Compact Neutron Scatter Cameras

    Science.gov (United States)

    Ruch, Marc L.

    The ability to locate and identify special nuclear material (SNM) is critical for treaty verification and emergency response applications. SNM is used as the nuclear explosive in a nuclear weapon. This material emits neutrons, either spontaneously or when interrogated. The ability to form an image of the neutron source can be used for characterization and/or to confirm that the item is a weapon by determining whether its shape is consistent with that of a weapon. Additionally, treaty verification and emergency response applications might not be conducive to non-portable instruments. In future weapons treaties, for example, it is unlikely that host countries will make great efforts to facilitate large, bulky, and/or fragile inspection equipment. Furthermore, inspectors and especially emergency responders may need to access locations not easily approachable by vehicles. Therefore, there is a considerable need for a compact, human-portable neutron imaging system. Of the currently available neutron imaging technologies, only neutron scatter cameras (NSCs) can be made truly compact because aperture-based imagers, and time-encoded imagers, rely on large amounts of materials to modulate the neutron signal. NSCs, in contrast, can be made very small because most of the volume of the imager can be filled with active detector material. Also, unlike other neutron imaging technologies, NSCs have the inherent ability to act as neutron spectrometers which gives them an additional means of identifying a neutron source. Until recently, NSCs have relied on photomultiplier tubes (PMT) readouts, which are bulky and fragile, require high voltage, and are very sensitive to magnetic fields. Silicon photomultipliers (SiPMs) do not suffer from these drawbacks and are comparable to PMTs in many respects such as gain, and cost with better time resolution. Historically, SiPMs have been too noisy for these applications; however, recent advancements have greatly reduced this issue and they have

  2. PM-tube sensitivity as a function of heating current in thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Forslo, M.; Carlsson, C.A.; Spanne, O.; Wik, S.

    1974-01-01

    A decrease in the sensitivity of the PM-tube in a commercial TLD-reader with increased number of repeated measurements is reported. Variations in sensitivity during the readout cycle is also mentioned. (author)

  3. The long-term stability and reliability of photomultipliers used in Anger scintillation cameras

    International Nuclear Information System (INIS)

    Persyk, D.E.

    1991-01-01

    A test instrument has been designed to measure the stability of PMT's (photomultiplier tubes) used in Anger scintillation cameras. The instrument is comprised of a number of glass capsules containing beta-emitting tritium with a blue phosphor to provide very stable light sources along with a data logger to monitor anode current. Three hundred sixty PMT's are simultaneously tested for anode luminous sensitivity, dark current, long-term drift rate, erratic gain instabilities and rms noise. In this paper results in the use of the instrument to test over 300 000 PMTs are discussed and the impact upon Auger camera reliability is assessed

  4. The long-term stability and reliability of photomultipliers used in Anger scintillation cameras

    International Nuclear Information System (INIS)

    Persyk, D. E.

    1990-01-01

    A test instrument has been designed to measure the stability of PMT's (photomultiplier tubes) used in Anger scintillation cameras. The instrument is comprised of a number of glass capsules containing beta-emitting tritium with a blue phosphor to provide very stable light sources along with a data logger to monitor anode current. Three hundred sixty PMT's are simultaneously tested for anode luminous sensitivity, dark current, long-term drift rate, erratic gain instabilities and rms noise. This paper discusses results in the use of the instrument to test over 300 000 PMT's and the impact upon Anger camera reliability is assessed

  5. Silicon photomultipliers for positron emission tomography detectors with depth of interaction encoding capability

    Energy Technology Data Exchange (ETDEWEB)

    Taghibakhsh, Farhad, E-mail: farhadt@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Thunder Bay Regional Health Science Centre, Thunder Bay, ON (Canada); Reznik, Alla [Thunder Bay Regional Health Science Centre, Thunder Bay, ON (Canada); Department of Physics, Lake Head University, Thunder Bay, ON (Canada); Rowlands, John A. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Thunder Bay Regional Health Science Centre, Thunder Bay, ON (Canada); Department of Physics, Lake Head University, Thunder Bay, ON (Canada)

    2011-05-15

    Silicon photomultipliers (SiPMs) are receiving increasing attention in the field of positron emission tomography (PET) detectors. Compared to photomultiplier tubes, they offer novel detector configurations for the extraction of depth of interaction (DOI) information, or enable emerging medical imaging modalities such as simultaneous PET-magnetic resonant imaging (MRI). In this article, we used 2x2x20 mm{sup 3} LYSO scintillator crystals coupled to SiPMs on both ends (dual-ended readout configuration) to evaluate the detector performance for DOI-PET applications. We investigated the effect of scintillator crystal surface finishing on sensitivity and resolution of DOI, as well as on energy and timing resolution. Measurements indicate DOI sensitivity and resolution of 7.1% mm{sup -1} and 2.1{+-}0.6 mm for saw-cut, and 1.3% mm{sup -1} and 9.0{+-}1.5 mm, for polished scintillator crystals, respectively. Energy resolution varies from 19% when DOI is in the center, to 15% with DOI at either end of the saw-cut crystal, while it remains constant at {approx}14% for polished scintillators. Based on our results we conclude that 2x2x20 mm{sup 3} saw-cut (without any special side wall polishing) LYSO crystals coupled to 2x2 mm{sup 2} silicon photomultipliers are optimal for isotropic 2 mm resolution DOI-PET applications.

  6. Geneva University - Silicon photomultiplier : features and applications

    CERN Multimedia

    Université de Genève

    2012-01-01

    GENEVA UNIVERSITY École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 Genève 4 Tél.: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 7 March 2012 SEMINAIRE DE PHYSIQUE CORPUSCULAIRE 11.15 a.m. - Science II, Auditoire 1S081, 30, quai Ernest-Ansermet, 1211 Genève 4 SILICON PHOTOMULTIPLIER : FEATURES AND APPLICATIONS Dr Giulio SARACINO   University of Naples, Federico II   Silicon photomultipliers were developed about ten years ago and their use, unlike traditional photomultiplier tubes, is increasing more and more. They are an evolution of the avalanche photodiode working in Geiger mode regime. Hundreds of such diodes are connected in parallel, allowing single photon response, high detection efficiency, high gain at low bias voltage and very good timing performance. In spite of their Geiger regime, they can be considered linear devices, until the number of photon...

  7. Sensitivity of the improved Dutch tube diffusion test for detection of ...

    African Journals Online (AJOL)

    The sensitivity of the improved two-tube test for detection of antimicrobial residues in Kenyan milk was investigated by comparison with the commercial Delvo test SP. Suspect positive milk samples (n =244) from five milk collection centers, were analyzed with the improved two-tube and the commercial Delvo SP test as per ...

  8. The sensitivity calibration of the ultra-fast quench plastic scintillation detector for D-T neutrons

    International Nuclear Information System (INIS)

    Tang Changhuan; Yan Meiqiong; Xie Chaomei

    1998-01-01

    The authors introduce some characteristics of ultra-fast quench plastic scintillation detectors. When the detectors are composed of different scintillators, light guides and microchannel plate photomultiplier tube (MCP-PMT), their sensitivities to D-T neutrons are calibrated by a pulse neutron tube with a neutron pulse width about 10 ns

  9. Solid-State Photomultiplier Development for Radiation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Stuart [NSTec; Brown, Kristina [NSTec; Curtis, Alden [NSTec; Young, Jason [NSTec; Guise, Ronald [NSTec

    2012-06-12

    We are pursuing the sensitivity of back-thinned silicon (BT Si) with the gain of an SSPM (Baker 2011). Working in collaboration with Radiation Monitoring Devices, Inc., we are designing and fabricating prototype devices. Our original idea spurred from hybrid designs of advanced image sensors that use the sensitivity of BT Si that is then bump bonded to a CMOS readout device. As shown in the graph below (right), the BT Si has a far superior quantum efficiency (QE) than the standard photocathode response available in photomultiplier tubes (PMTs). Collecting as many scintillation photons as possible is the first objective. There has been major concern that the prototype could not deliver the ~105 electronic gain of a PMT. However, recently developed SSPMs do provide the electronic gain needed. We are now pursuing the design of a BTSSPM. With a smaller footprint, the SSPM can potentially lead to a simple, compact deployment package. Because the SSPM can be pixelated and tiled, we foresee developing an imaging detector. Pinhole imaging of radiation sources is a well-exercised technology. Our implementation of the coded aperture (Marks 2010) imager provides a high throughput pinhole imager. We intend to apply miniature coded apertures to minimal pixel count SSPMs to evaluate image quality.

  10. Position sensitive detector with semiconductor and image electron tube comprising such a detector

    International Nuclear Information System (INIS)

    Roziere, Guy.

    1977-01-01

    This invention concerns a position sensitive detector comprising a semiconducting substrate. It also concerns the electron tubes in which the detector may be incorporated in order to obtain an image formed at the tube input by an incident flux of particles or radiation. When a charged particle or group of such particles, electrons in particular, enter the space charge region of an inversely biased semiconductor diode, the energy supplied by these particles releases in the diode a certain number of electron-hole pairs which move in the field existing in the area towards the diode contacts. A corresponding current arises in the connections of this diode which constitutes the signal corresponding to the incident energy. Such a tube or chain of tubes is employed in nuclear medicine for observing parts of the human body, particularly by gamma radiation [fr

  11. Development of gamma spectrometer using silicon photomultiplier (SiPM)

    International Nuclear Information System (INIS)

    Kim, Chan Kyu

    2011-02-01

    Gamma spectroscopy is used to determine the identity and quantity of gamma-emitters in nuclear physics, geochemistry and astrophysics. The scintillation detectors are being used as a gamma spectrometer generally, because of their higher gamma-ray detection efficiency and cheaper price than germanium semi-conductor detectors. A typical scintillation detector is composed of a scintillator, a window, and a photodetector. The photomultiplier (PM) tube has been the most widely used as a photodetector because of its advantages like high sensitivity, high signal-to-noise ratio, and wide dynamic range. Recently, the Silicon Photomultiplier (SiPM) is being studied as a substitute of PM tube. The SiPM has almost same performance compared to PM tube but it has additional advantages; low operating voltage, small volume, and cheap production cost. In this research, the gamma spectrometer using SiPM instead of PM tube is developed. The use of SiPM as a photodetector makes the gamma spectrometer smaller, cheaper, easier to use. For photon transport and collection from the large area scintillator to the small area SiPM, a light guide is applied in this gamma spectrometer system. Before fabrication of light guide, DETECT simulation is performed to study and prospect characteristics of light guide structure. And actual light guides are fabricated on the basis of this simulation result. Poly(methyl methacrylate) (PMMA) is chosen as material of light guide, 5 sample light guides are fabricated in different lengths and coatings. As a scintillator crystal, same NaI(Tl) crystal is chosen. For measurement and analysis of gamma spectrometer system, 3 gamma spectrometer systems are composed: PM tube-based system, PM tube-based system with the light guide, SiPM-based system with the light guide. Through comparison between the results of each gamma spectrometer, the performances of gamma spectrometer system are analyzed by each component. Measurement results of the second system is well

  12. An amplifier for VUV photomultiplier operating in cryogenic environment

    Energy Technology Data Exchange (ETDEWEB)

    Arneodo, F.; Benabderrahmane, M.L.; Dahal, S. [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Di Giovanni, A., E-mail: adriano.digiovanni@nyu.edu [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); D' Inzeo, M.; Franchi, G. [Age Scientific srl – Capezzano Pianore (Italy); Pazos Clemens, L. [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates)

    2016-07-11

    We present the characterisation of an amplifier potentially interesting for noble liquid detectors. The design has been conceived considering the requirements of low power consumption (less than 30 mW), low noise, amplification factor of 10 at 100 MHz and use of commercial components. The amplifier has been integrated onto an electronic board with a voltage divider to operate an Hamamatsu R11410 photomultiplier tube (used in XENON1T, Aprile et al. (2014) [1] dark matter experiment).

  13. Batch production of microchannel plate photo-multipliers

    Energy Technology Data Exchange (ETDEWEB)

    Frisch, Henry J.; Wetstein, Matthew; Elagin, Andrey

    2018-03-06

    In-situ methods for the batch fabrication of flat-panel micro-channel plate (MCP) photomultiplier tube (PMT) detectors (MCP-PMTs), without transporting either the window or the detector assembly inside a vacuum vessel are provided. The method allows for the synthesis of a reflection-mode photocathode on the entrance to the pores of a first MCP or the synthesis of a transmission-mode photocathode on the vacuum side of a photodetector entrance window.

  14. Silicon Photomultipliers (SiPM) as novel photodetectors for PET

    International Nuclear Information System (INIS)

    Del Guerra, Alberto; Belcari, Nicola; Giuseppina Bisogni, Maria; Corsi, Francesco; Foresta, Maurizio; Guerra, Pedro; Marcatili, Sara; Santos, Andres; Sportelli, Giancarlo

    2011-01-01

    Next generation PET scanners should fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultipliers (SiPMs) is proposed for the construction of a 4D-PET module of 4.8x4.8 cm 2 aimed to replace the standard PMT based PET block detector. The module will be based on a LYSO continuous crystal read on two faces by Silicon Photomultipliers. A high granularity detection surface made by SiPM matrices of 1.5 mm pitch will be used for the x-y photon hit position determination with submillimetric accuracy, while a low granularity surface constituted by 16 mm 2 SiPM pixels will provide the fast timing information (t) that will be used to implement the Time of Flight technique (TOF). The spatial information collected by the two detector layers will be combined in order to measure the Depth of Interaction (DOI) of each event (z). The use of large area multi-pixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Data Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities and to manage many channels. The paper describes the progress made on the development of the proof of principle module under construction at the University of Pisa.

  15. Automatic arc welding of propulsion system tubing in close proximity to sensitive electronic devices

    Science.gov (United States)

    Lumsden, J. M.; Whittlesey, A. C.

    1981-01-01

    The planned final assembly of the Galileo spacecraft propulsion system tubing, which involves welding in close proximity to sensitive electronics, raised significant concerns about the effects of electromagnetic coupling of weld energy on CMOS and other sensitive integrated circuits. A test program was established to assess the potential of an orbital arc welder and an RF-induction brazing machine to damage sensitive electronic equipment. Test parameters were varied to assess the effectiveness of typical transient suppression practices such as grounding, bonding, and shielding. A technique was developed to calibrate the hazard levels at the victim-circuit location; this technique is described along with the results and conclusions of the test program.

  16. Development of a scintillating optical fiber dosimeter with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Moutinho, L.M., E-mail: moutinho@ua.pt [I3N, Physics Department, University of Aveiro (Portugal); Castro, I.F. [I3N, Physics Department, University of Aveiro (Portugal); Peralta, L. [Faculdade de Ciências da Universidade de Lisboa (Portugal); Laboratório de Instrumentação e Física Experimental de Partículas, LIP-Lisboa (Portugal); Abreu, M.C. [Laboratório de Instrumentação e Física Experimental de Partículas, LIP-Lisboa (Portugal); Veloso, J.F.C.A. [I3N, Physics Department, University of Aveiro (Portugal)

    2014-01-21

    A radiation dosimeter for low dose rates based on a scintillating optical fiber coupled to a high gain photon-counting silicon photomultiplier (SiPM) for light readout was developed. The dosimeter satisfies most of the requirements for in-vivo, low dose-rate and real-time dosimetry. The device uses a small scintillator, is flexible and reasonably water-equivalent for photon energies above 100 keV [1,2]. Promising results were obtained when operating the device in current mode, detecting radiation from an X-ray tube in the 15–40 kV range and for anode currents as low as a few μA. As single-photon detectors, the major drawback of SiPMs is their high dark count rate (noise), which is a problem for low dose rate measurements in single photon counting mode. This drawback can be reduced by cooling the SiPMs or by using a much more efficient proposed solution in which two SiPMs operate in coincidence mode reading out the same optical fiber, thus allowing the rejection of false events triggered by dark noise. We have implemented a simple low-cost system, with dedicated front-end electronics operating in pulse mode for coincidence detection. Performance studies of the dosimeter operating in current mode, as a function of the X-ray tube current and voltage, show good sensitivity even for low radiation dose. When operating in pulse mode under low activity gamma irradiation, the coincidence system was able to reduce the dark noise to a residual value. -- Highlights: • Development of a plastic scintillation detector for low dose and low energy dosimetry. • Possibility of SiPMs as photosensor for a real-time dosimetry. • Operation in coincidence mode minimizes the effect of dark noise of the SiPM.

  17. Studies on a silicon-photomultiplier-based camera for Imaging Atmospheric Cherenkov Telescopes

    Science.gov (United States)

    Arcaro, C.; Corti, D.; De Angelis, A.; Doro, M.; Manea, C.; Mariotti, M.; Rando, R.; Reichardt, I.; Tescaro, D.

    2017-12-01

    Imaging Atmospheric Cherenkov Telescopes (IACTs) represent a class of instruments which are dedicated to the ground-based observation of cosmic VHE gamma ray emission based on the detection of the Cherenkov radiation produced in the interaction of gamma rays with the Earth atmosphere. One of the key elements of such instruments is a pixelized focal-plane camera consisting of photodetectors. To date, photomultiplier tubes (PMTs) have been the common choice given their high photon detection efficiency (PDE) and fast time response. Recently, silicon photomultipliers (SiPMs) are emerging as an alternative. This rapidly evolving technology has strong potential to become superior to that based on PMTs in terms of PDE, which would further improve the sensitivity of IACTs, and see a price reduction per square millimeter of detector area. We are working to develop a SiPM-based module for the focal-plane cameras of the MAGIC telescopes to probe this technology for IACTs with large focal plane cameras of an area of few square meters. We will describe the solutions we are exploring in order to balance a competitive performance with a minimal impact on the overall MAGIC camera design using ray tracing simulations. We further present a comparative study of the overall light throughput based on Monte Carlo simulations and considering the properties of the major hardware elements of an IACT.

  18. Neutron detection with plastic scintillators coupled to solid state photomultiplier detectors

    Science.gov (United States)

    Christian, James F.; Johnson, Erik B.; Fernandez, Daniel E.; Vogel, Samuel; Frank, Rebecca; Stoddard, Graham; Stapels, Christopher; Pereira, Jorge; Zegers, Remco

    2017-09-01

    The recent reduction of dark current in Silicon Solid-state photomultipliers (SiSSPMs) makes them an attractive alternative to conventional photomultiplier tubes (PMTs) for scintillation detection applications. Nuclear Physics experiments often require large detector volumes made using scintillation materials, which require sensitive photodetectors, such as a PMTs. PMTs add to the size, fragility, and high-voltage requirements as well as distance requirements for experiments using magnetic fields. This work compares RMD's latest detector modules, denoted as the "year 2 prototype", of plastic scintillators that discriminate gamma and high-energy particle events from neutron events using pulse shape discrimination (PSD) coupled to a SiSSPM to the following two detector modules: a similar "year 1 prototype" and a scintillator coupled to a PMT module. It characterizes the noise floor, relative signal-to-noise ratio (SNR), the timing performance, the PSD figure-of-merit (FOM) and the neutron detection efficiency of RMD's detectors. This work also evaluates the scaling of SiSSPM detector modules to accommodate the volumes needed for many Nuclear Physics experiments. The Si SSPM detector module provides a clear advantage in Nuclear Physics experiments that require the following attributes: discrimination of neutron and gamma-ray events, operation in or near strong magnetic fields, and segmentation of the detector.

  19. Development of a large area microstructure photomultiplier assembly (LAMPA)

    Science.gov (United States)

    Clifford, E. T. H.; Dick, M.; Facina, M.; Wakeford, D.; Andrews, H. R.; Ing, H.; Best, D.; Baginski, M. J.

    2017-05-01

    Large area (> m2) position-sensitive readout of scintillators is important for passive/active gamma and neutron imaging for counter-terrorism applications. The goal of the LAMPA project is to provide a novel, affordable, large-area photodetector (8" x 8") by replacing the conventional dynodes of photomultiplier tubes (PMTs) with electron multiplier microstructure boards (MSBs) that can be produced using industrial manufacturing techniques. The square, planar format of the LAMPA assemblies enables tiling of multiple units to support large area applications. The LAMPA performance objectives include comparable gain, noise, timing, and energy resolution relative to conventional PMTs, as well as spatial resolution in the few mm range. The current LAMPA prototype is a stack of 8" x 8" MSBs made commercially by chemical etching of a molybdenum substrate and coated with hydrogen-terminated boron-doped diamond for high secondary emission yield (SEY). The layers of MSBs are electrically isolated using ceramic standoffs. Field-shaping grids are located between adjacent boards to achieve good transmission of electrons from one board to the next. The spacing between layers and the design of the microstructure pattern and grids were guided by simulations performed using an electro-optics code. A position sensitive anode board at the back of the stack of MSBs provides 2-D readout. This presentation discusses the trade studies performed in the design of the MSBs, the measurements of SEY from various electro-emissive materials, the electro-optics simulations conducted, the design of the 2-D readout, and the mechanical aspects of the LAMPA design, in order to achieve a gain of > 104 in an 8-stage stack of MSBs, suitable for use with various scintillators when coupled to an appropriate photocathode.

  20. The Megapixel EBCCD a high-resolution imaging tube sensitive to single photons

    CERN Document Server

    Buontempo, S; Dalinenko, I N; Ereditato, A; Ekimov, A V; Fabre, Jean-Paul; Fedorov, V Yu; Frenkel, A; Galeazzi, F; Garufi, F; Golovkin, S V; Govorun, V N; Kalashnikova, N N; Kosov, V G; Kozarenko, E N; Kreslo, I E; Lasovsky, L Y; Liberti, B; Malyarov, A V; Martellotti, G; Medvedkov, A M; Penso, G; Vishnevski, G I; Wolff, T; Zhuk, A

    1998-01-01

    A hybrid image-intensifier tube, suitable for extremely low-light imaging, has been tested. This device is based on an Electron-Bombarded CCD chip (EBCCD) with $1024 \\times 1024$ sensitive pixe ls. The tube, which has a photocathode diameter of 40 mm, is gateable and zoomable, with an image magnification varying from 0.62 to 1.3. The high gain (about 4000 collected electrons per photo electron at the operational voltage of 15 kV) and the relatively low noise (180 electrons per pixel at 10 MHz pixel-readout frequency), allows single-photoelectron signals to be separated from n oise with a signal-to-noise ratio greater than 10. By applying an appropriate threshold on the signal amplitude, the background can almost be eliminated, with a loss of few percent in single-ph otoelectron counting. High inner gain, low noise, single-photoelectron sensitivity, and high spatial resolution make the EBCCD imaging tube a unique device, attractive for many applications in h igh-energy physics, astrophysics, biomedical diagnos...

  1. Investigating the temperature dependence of photomultiplier quantum efficiency when operating in the visible spectrum

    CERN Document Server

    Clawson, Savannah Ellen

    2017-01-01

    The quantum efficiency of a Burle 8850 photomultiplier tube with a potassium-caesium-antimony (bialkali) photocathode was determined by attenuating a 1 mW HeNe laser emitting at 633 nm and measuring the signal frequency when the laser was incident on the photomultiplier. A temperature range of 5 $^{\\circ}$C $-$ 20 $^{\\circ}$C was investigated and it was found that the quantum efficiency decreases with temperature, with the signal frequency decreasing at a faster rate than the dark current frequency. Therefore, it was concluded that it would not be beneficial to cool photomultiplier tubes operating in the visible spectrum for use in collinear laser spectroscopy due to a decreasing signal-to-noise ratio. The signal pulse height distribution was also analysed and found to be independent of temperature within the range investigated.

  2. Silicon photomultipliers in AMIGA muon counters

    Energy Technology Data Exchange (ETDEWEB)

    Botti, Ana Martina [Institut fuer Kernphysik, Karlsruher Institut fuer Technologie (Germany); Instituto de Tecnologias en Deteccion y Astroparticulas (ITeDA) (Argentina); Collaboration: Pierre-Auger-Collaboration

    2016-07-01

    The project AMIGA (Auger Muons and Infill for the Ground Array) aims to extend the energy range at the Pierre Auger Observatory to observe cosmic rays of lower energies (down to ∝10{sup 17} eV) and to study the transition from extragalactic to galactic cosmic rays. AMIGA is compounded by an infill of surface detectors (employing Cherenkov radiation detection in water) and muon counters. The AMIGA muon counters consist of an array of buried modules composed of 64 scintillator bars, a multi-pixel Photo Multiplier Tube (PMT) and the corresponding electronic of acquisition which works along with the surface detector. Currently, ITeDA is evaluating the feasibility of replacing PMTs with silicon photomultipliers (SiPM) without performing any substantial modification in the digital readout nor in the mechanical design. I present calibration results of a prototype module associated to the surface detector Toune of the Pierre Auger Observatory using a SiPM Hamamatsu S1257-100C plugged to the standard AMIGA front-end electronics. In addition, a study concerning gain stability and temperature variation has also been performed and is reported. I finally discuss a comparison between traces measured by both photodetectors (PMT and SiPM) for modules associated to the surface detector Toune.

  3. Charge reconstruction in large-area photomultipliers

    Science.gov (United States)

    Grassi, M.; Montuschi, M.; Baldoncini, M.; Mantovani, F.; Ricci, B.; Andronico, G.; Antonelli, V.; Bellato, M.; Bernieri, E.; Brigatti, A.; Brugnera, R.; Budano, A.; Buscemi, M.; Bussino, S.; Caruso, R.; Chiesa, D.; Corti, D.; Dal Corso, F.; Ding, X. F.; Dusini, S.; Fabbri, A.; Fiorentini, G.; Ford, R.; Formozov, A.; Galet, G.; Garfagnini, A.; Giammarchi, M.; Giaz, A.; Insolia, A.; Isocrate, R.; Lippi, I.; Longhitano, F.; Lo Presti, D.; Lombardi, P.; Marini, F.; Mari, S. M.; Martellini, C.; Meroni, E.; Mezzetto, M.; Miramonti, L.; Monforte, S.; Nastasi, M.; Ortica, F.; Paoloni, A.; Parmeggiano, S.; Pedretti, D.; Pelliccia, N.; Pompilio, R.; Previtali, E.; Ranucci, G.; Re, A. C.; Romani, A.; Saggese, P.; Salamanna, G.; Sawy, F. H.; Settanta, G.; Sisti, M.; Sirignano, C.; Spinetti, M.; Stanco, L.; Strati, V.; Verde, G.; Votano, L.

    2018-02-01

    Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid Scintillator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos' extremely elusive nature. Depending on the detector light yield, several scintillation photons stemming from the same neutrino interaction are likely to hit a single PMT in a few tens/hundreds of nanoseconds, resulting in several photoelectrons (PEs) to pile-up at the PMT anode. In such scenario, the signal generated by each PE is entangled to the others, and an accurate PMT charge reconstruction becomes challenging. This manuscript describes an experimental method able to address the PMT charge reconstruction in the case of large PE pile-up, providing an unbiased charge estimator at the permille level up to 15 detected PEs. The method is based on a signal filtering technique (Wiener filter) which suppresses the noise due to both PMT and readout electronics, and on a Fourier-based deconvolution able to minimize the influence of signal distortions—such as an overshoot. The analysis of simulated PMT waveforms shows that the slope of a linear regression modeling the relation between reconstructed and true charge values improves from 0.769 ± 0.001 (without deconvolution) to 0.989 ± 0.001 (with deconvolution), where unitary slope implies perfect reconstruction. A C++ implementation of the charge reconstruction algorithm is available online at [1].

  4. Sensitive Mid-IR Laser Sensor Development and Mass Spectrometric Measurements in Shock Tube and Flames

    KAUST Repository

    Alquaity, Awad

    2016-11-01

    With global emission regulations becoming stringent, development of new combustion technologies that meet future emission regulations is essential. In this vein, this dissertation presents the application of sensitive diagnostic tools to validate and improve chemical kinetic mechanisms that play a fundamental role in the design of new combustion technologies. First, a novel high sensitivity laser-based sensor with a wide frequency tuning range (900 – 1000 cm-1) was developed utilizing pulsed cavity ringdown spectroscopy (CRDS) technique. The novel laser-based sensor was illustrated by measuring trace amounts of multiple combustion intermediates, namely ethylene, propene, allene, and 1-butene in a static cell at ambient conditions. Subsequently, pulsed CRDS technique was utilized to develop an ultra-fast, high sensitivity diagnostic to monitor trace concentrations of ethylene in shock tube pyrolysis experiments. This diagnostic represented the first ever successful application of CRDS technique to transient species measurements in a shock tube. The high sensitivity and fast time response (10μs) diagnostic may be utilized for measuring other key neutrals and radicals which are crucial in the oxidation chemistry of practical fuels. Secondly, a quadrupole mass spectrometer (QMS) was employed to measure relative cation mole fractions in atmospheric and low-pressure (30 Torr) flames of methane/oxygen diluted in argon. Lean, stoichiometric and rich flames were 4 examined to evaluate the dependence of ion chemistry on flame stoichiometry. Spatial distribution of cations was compared with predictions of an existing ion chemistry model. Based on the extensive measurements carried out in this work, modifications were suggested to improve the ion chemistry model to enhance the fidelity of such mechanisms. In-depth understanding of flame ion chemistry is vital to model the interaction of flames with electric fields and thereby pave the way to enable active combustion control

  5. An Educational Kit Based On a Modular Silicon Photomultiplier System

    International Nuclear Information System (INIS)

    Caccia, Massimo; Chmill, Valery; Ebolese, Amedeo; Martemyanov, Alexander; Risigo, Fabio; Santoro, Romualdo; Locatelli, Marco; Pieracci, Maura; Tintori, Carlo

    2013-06-01

    Silicon Photo-Multipliers (SiPM) are state of the art light detectors with unprecedented single photon sensitivity and photon number resolving capability, representing a breakthrough in several fundamental and applied Science domains. An educational experiment based on a SiPM set-up is proposed in this article, guiding the student towards a comprehensive knowledge of this sensor technology while experiencing the quantum nature of light and exploring the statistical properties of the light pulses emitted by a LED. (authors)

  6. Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes

    International Nuclear Information System (INIS)

    Sinha, A.; Panchal, C.G.; Shyam, A.; Srinivasan, M.; Joshi, V.M.

    1996-01-01

    An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.)

  7. Silicon photomultiplier timing performance study

    Science.gov (United States)

    Gamal, Ahmed; Paul, Bühler; Johann, Marton; Ken, Suzuki

    2011-10-01

    Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area Multi-Pixel Photon Counters (MPPCs) manufactured by Hamamatsu. Measurements at -10, 0, and 10 °C at different bias voltages were performed. The time resolution is best at low temperature and high over-voltage. Most significant improvements can be achieved in cases with low number of fired pixels (40 pixels) the effect of temperature and operation voltage becomes smaller. The timing performance still improves with decreasing temperature ( ≈factor of 2) but it hardly depends on the operation voltage. The study shows that especially in applications where only few photons are available for detection a careful optimization of temperature and operation voltage are advisable to obtain optimum timing results with the MPPC.

  8. Confirming nasogastric tube placement: Is the colorimeter as sensitive and specific as X-ray? A diagnostic accuracy study.

    Science.gov (United States)

    Mordiffi, Siti Zubaidah; Goh, Mien Li; Phua, Jason; Chan, Yiong-Huak

    2016-09-01

    The effect of delivering enteral nutrition or medications via a nasogastric tube that is inadvertently located in the tracheobronchial tract can cause respiratory complications. Although radiographic examination is accepted as the gold standard for confirming the position of patients' enteral tubes, it is costly, involves risks of radiation, and is not failsafe. Studies using carbon dioxide sensors to detect inadvertent nasogastric tube placements have been conducted in intensive care settings. However, none involved patients in general wards. The objective of this study was to ascertain the diagnostic measure of colorimeter, with radiographic examination as the reference standard, to confirm the location of nasogastric tubes in patients. A prospective observational study of a diagnostic test. This study was conducted in the general wards of an approximately 1100-bed acute care tertiary hospital of an Academic Medical Center in Singapore. Adult patients with nasogastric tubes admitted to the general wards were recruited into the study. The colorimeter was attached to the nasogastric tube to detect for the presence of carbon dioxide, suggestive of a tracheobronchial placement. The exact location of the nasogastric tube was subsequently confirmed by a radiographic examination. A total of 192 tests were undertaken. The colorimeter detected carbon dioxide in 29 tested nasogastric tubes, of which radiographic examination confirmed that four tubes were located in the tracheobronchial tract. The colorimeter failed to detect carbon dioxide in one nasogastric tube that was located in the tracheobronchial tract, thus, demonstrating a sensitivity of 0.80 [95% CI (0.376, 0.964)]. The colorimeter detected absence of carbon dioxide in 163 tested nasogastric tubes in which radiographic examination confirmed 160 gastrointestinal and one tracheobronchial placements, demonstrating a specificity of 0.865 [95% CI (0.808, 0.907)]. The colorimeter detected one tracheobronchial

  9. Silicon photomultipliers and their bio-medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Grigoriev, Eugene [Institute for Theoretical and Experimental Physics (ITEP), B.Cheremushkinskaya 25, Moscow 117218 (Russian Federation) and Forimtech S.A., Route de Malagnou 32, Geneva 1208 (Switzerland)]. E-mail: grigoriev@forimtech.ch; Akindinov, Alexander [Institute for Theoretical and Experimental Physics (ITEP), B.Cheremushkinskaya 25, Moscow 117218 (Russian Federation); Breitenmoser, Marco [Forimtech S.A., Route de Malagnou 32, Geneva 1208 (Switzerland); Buono, Stefano [Advanced Accelerator Applications S.A (AAA), 20 rue Diesel, 01630 St. Genis Pouilly (France); Charbon, Edoardo [Ecole Politechnique Federale de Lausanne (EPFL), AQUA Group, Lausanne 1015 (Switzerland); Niclass, Cristiano [Ecole Politechnique Federale de Lausanne (EPFL), AQUA Group, Lausanne 1015 (Switzerland); Desforges, Iris [Forimtech S.A., Route de Malagnou 32, Geneva 1208 (Switzerland); Rocca, Roberto [Advanced Accelerator Applications S.A (AAA), 20 rue Diesel, 01630 St. Genis Pouilly (France)

    2007-02-01

    Single Photon Avalanche Diodes (SPADs) have been used for photon counting since the 1960s, but only in the recent decade multi-pixel structures based on SPAD-arrays and silicon photomultipliers have been developed. These devices are finding more and more applications in many fields, where detection of light at the level of a single photon is needed. Due to their exclusive properties (fast response, low operating voltage, single photon sensitivity at room temperature, extremely high gain, stability, compactness, robustness and low price), such sensors are successfully replacing traditional vacuum photomultipliers in many devices. The paper briefly describes the state of the art and suggests some new applications in biology and medicine.

  10. Photocopia-A Unibody Mono-material Compact and Scalable Photomultiplier

    Energy Technology Data Exchange (ETDEWEB)

    Mulhollan, Gregory [Saxet Surface Science

    2014-12-01

    The Photocopia photomultiplier tube (PMT) takes advantage of two of the many unique properties of the hydrogenated amorphous silicon-germanium (a-SiGe) photoemitter material: its mechanical flexibility and mostly substrate-independent properties. The a-SiGe photoemitter has high secondary electron (SE) yield. It can be used both as the photocathode and as the gain medium. The active material can be grown on a flat, thin unibody substrate, formed and then “rolled up” ex situ. The completed structure would then be activated and sealed within a tube. The Ge component can be increased to enhance red-sensitivity. Compact sizes are possible, minimizing magnetic field effects. The Photocopia PMT will be a low cost alternative to MCPs for TOF detectors and provide better timing discrimination for Cherenkov detectors. Retention of the ability to activate to a normal photoyield state upon flexing (bending) the substrate of the a-SiGe material after growth, but prior to activation has been shown. The SE coefficient of the activated material has been characterized over the voltage range suitable for utilization as the gain material. The time response of the material is suited to PMT use.

  11. Simulation of Silicon Photomultiplier Signals

    Science.gov (United States)

    Seifert, Stefan; van Dam, Herman T.; Huizenga, Jan; Vinke, Ruud; Dendooven, Peter; Lohner, Herbert; Schaart, Dennis R.

    2009-12-01

    In a silicon photomultiplier (SiPM), also referred to as multi-pixel photon counter (MPPC), many Geiger-mode avalanche photodiodes (GM-APDs) are connected in parallel so as to combine the photon counting capabilities of each of these so-called microcells into a proportional light sensor. The discharge of a single microcell is relatively well understood and electronic models exist to simulate this process. In this paper we introduce an extended model that is able to simulate the simultaneous discharge of multiple cells. This model is used to predict the SiPM signal in response to fast light pulses as a function of the number of fired cells, taking into account the influence of the input impedance of the SiPM preamplifier. The model predicts that the electronic signal is not proportional to the number of fired cells if the preamplifier input impedance is not zero. This effect becomes more important for SiPMs with lower parasitic capacitance (which otherwise is a favorable property). The model is validated by comparing its predictions to experimental data obtained with two different SiPMs (Hamamatsu S10362-11-25u and Hamamatsu S10362-33-25c) illuminated with ps laser pulses. The experimental results are in good agreement with the model predictions.

  12. Modeling crosstalk in silicon photomultipliers

    International Nuclear Information System (INIS)

    Gallego, L; Rosado, J; Blanco, F; Arqueros, F

    2013-01-01

    Optical crosstalk seriously limits the photon-counting resolution of silicon photomultipliers. In this work, realistic analytical models to describe the crosstalk effects on the response of these photodetectors are presented and compared with experimental data. The proposed models are based on the hypothesis that each pixel of the array has a finite number of available neighboring pixels to excite via crosstalk. Dead-time effects and geometrical aspects of the propagation of crosstalk between neighbors are taken into account in the models for different neighborhood configurations. Simple expressions to account for crosstalk effects on the pulse-height spectrum as well as to evaluate the excess noise factor due to crosstalk are also given. Dedicated measurements were carried out under both dark-count conditions and pulsed illumination. Moreover, the influence of afterpulsing on the measured pulse-height spectrum was studied, and a measurement of the recovery time of pixels was reported. High-resolution pulse-height spectra were obtained by means of a detailed waveform analysis, and the results have been used to validate our crosstalk models.

  13. Silicon photomultiplier timing performance study

    Energy Technology Data Exchange (ETDEWEB)

    Gamal, Ahmed, E-mail: gamal.ahmed@assoc.oeaw.ac.at [Stefan Meyer Institute for Subatomic Physics of the Austrian Academy of Sciences, Vienna (Austria); Al-Azhar University, Faculty of Science, Physics Department, Cairo (Egypt); Paul, Buehler; Johann, Marton; Ken, Suzuki [Stefan Meyer Institute for Subatomic Physics of the Austrian Academy of Sciences, Vienna (Austria)

    2011-10-01

    Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area Multi-Pixel Photon Counters (MPPCs) manufactured by Hamamatsu. Measurements at -10, 0, and 10 deg. C at different bias voltages were performed. The time resolution is best at low temperature and high over-voltage. Most significant improvements can be achieved in cases with low number of fired pixels (<10pixels). Between the worst and best case among the considered conditions a factor of five improvement was observed. In cases with large number of fired pixels (>40pixels) the effect of temperature and operation voltage becomes smaller. The timing performance still improves with decreasing temperature ({approx}factor of 2) but it hardly depends on the operation voltage. The study shows that especially in applications where only few photons are available for detection a careful optimization of temperature and operation voltage are advisable to obtain optimum timing results with the MPPC.

  14. Highly sensitive contact pressure measurements using FBG patch in endotracheal tube cuff

    Science.gov (United States)

    Correia, R.; Blackman, O. R.; Hernandez, F. U.; Korposh, S.; Morgan, S. P.; Hayes-Gill, B. R.; James, S. W.; Evans, D.; Norris, A.

    2016-05-01

    A method for measuring the contact pressure between an endotracheal tube cuff and the trachea was designed and developed by using a fibre Bragg grating (FBG) based optical fibre sensor. The FBG sensor is encased in an epoxy based UV-cured cuboid patch and transduces the transversely loaded pressure into an axial strain that induces wavelength shift of the Bragg reflection. The polymer patch was created by using a PTFE based mould and increases tensile strength and sensitivity of the bare fibre FBG to pressure to 2.10×10-2 nm/kPa. The characteristics of the FBG patch allow for continuous measurement of contact pressure. The measurement of contact pressure was demonstrated by the use of a 3D printed model of a human trachea. The influence of temperature on the measurements is reduced significantly by the use of a second FBG sensor patch that is not in contact with the trachea. Intracuff pressure measurements performed using a commercial manometer agreed well with the FBG contact pressure measurements.

  15. Hybrid photomultipliers – their properties and application in scintillation studies

    CERN Document Server

    Mares, J A

    2007-01-01

    A principle of a hybrid photodetection and of a hybrid photomultiplier (HPMT) will be described. HPMT consists of a photocathode and an anode which is the silicon PIN diode. About 280 electron–hole pairs per 1 kV and up to 15 kV accelerating voltage can be used. From beginning of nineties of the last century the HPMTs are used in scintillation response studies. They show high sensitivity in the measurements of Nphels photoelectron yield starting from 20 ph/MeV (at PbWO4) without an upper limit.

  16. Modeling Photo-multiplier Gain and Regenerating Pulse Height Data for Application Development

    Science.gov (United States)

    Aspinall, Michael D.; Jones, Ashley R.

    2018-01-01

    Systems that adopt organic scintillation detector arrays often require a calibration process prior to the intended measurement campaign to correct for significant performance variances between detectors within the array. These differences exist because of low tolerances associated with photo-multiplier tube technology and environmental influences. Differences in detector response can be corrected for by adjusting the supplied photo-multiplier tube voltage to control its gain and the effect that this has on the pulse height spectra from a gamma-only calibration source with a defined photo-peak. Automated methods that analyze these spectra and adjust the photo-multiplier tube bias accordingly are emerging for hardware that integrate acquisition electronics and high voltage control. However, development of such algorithms require access to the hardware, multiple detectors and calibration source for prolonged periods, all with associated constraints and risks. In this work, we report on a software function and related models developed to rescale and regenerate pulse height data acquired from a single scintillation detector. Such a function could be used to generate significant and varied pulse height data that can be used to integration-test algorithms that are capable of automatically response matching multiple detectors using pulse height spectra analysis. Furthermore, a function of this sort removes the dependence on multiple detectors, digital analyzers and calibration source. Results show a good match between the real and regenerated pulse height data. The function has also been used successfully to develop auto-calibration algorithms.

  17. Characterization of the 10-stages R5900 Hamamatsu photomultipliers for the hadronic ATLAS calorimeter

    International Nuclear Information System (INIS)

    Montarou, G.; Bouhemaid, N.; Grenier, Ph.; Crouau, M.; Muanza, G.S.; Poirot, S.; Vazeille, F.; Gil Botella, I.; Hoz, S.G. de la

    1997-01-01

    The measurements carried out, at Clermont on the R5900 Hamamatsu photomultipliers for the ATLAS hadronic calorimeter are summarised. The TILECAL specifications are given. Amplification measurements, dark current measurements, linearity, magnetic sensitivity and the voltage divider optimisation are presented. (K.A.)

  18. Characterization of the 10-stages R5900 Hamamatsu photomultipliers for the hadronic ATLAS calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Montarou, G.; Bouhemaid, N.; Grenier, Ph.; Crouau, M.; Muanza, G.S.; Poirot, S.; Vazeille, F. [Clermont-Ferrand-2 Univ., 63 - Aubiere (France). Lab. de Physique Corpusculaire; Gil Botella, I.; Hoz, S.G. de la [Valencia Univ., Burjassot (Spain) Inst. de Fisica Corpuscular

    1997-12-31

    The measurements carried out, at Clermont on the R5900 Hamamatsu photomultipliers for the ATLAS hadronic calorimeter are summarised. The TILECAL specifications are given. Amplification measurements, dark current measurements, linearity, magnetic sensitivity and the voltage divider optimisation are presented. (K.A.).

  19. Application of the silicon photomultipliers for detectors in the GlueX experiment

    Energy Technology Data Exchange (ETDEWEB)

    Somov, Sergey V. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Kashirskoe shosse 31, Moscow, 115409, Russia; Tolstukhin, Ivan [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Kashirskoe shosse 31, Moscow, 115409, Russia; Somov, Alexander S. [Jefferson Lab, Newport News, VA

    2015-11-01

    The GlueX detector in Hall D at Jefferson Lab is instrumented with about 5000 Silicon Photomultipliers (SiPM) manufactured by Hamamatsu Corporation [2]. These photo sensors have properties similar to conventional photomultipliers but can be operated at high magnetic fields. Silicon photomultipliers with a sensitive area of 3x3 mm2 are used to detect light from the following GlueX scintillator detectors: the tagger microscope, pair spectrometer, and start counter. Arrays of 4x4 SiPMs sensors were chosen for the instrumentation of the barrel electromagnetic calorimeter. The tagger microscope must operate at high rates (up to 2.5 MHz) and provide time measurements with a resolution better than 0.3 ns. The paper will describe some results of the characterization of SiPMs for various GlueX sub-detectors.

  20. Segmented scintillation detectors with silicon photomultiplier readout for measuring antiproton annihilations

    CERN Document Server

    Sótér, A.; Kobayashi, T.; Barna, D.; Horváth, D.; Hori, M.

    2014-01-01

    The Atomic Spectroscopy and Collisions Using Slow Antiprotons (ASACUSA) experiment at the Antiproton Decelerator (AD) facility of CERN constructed segmented scintillators to detect and track the charged pions which emerge from antiproton annihilations in a future superconducting radiofrequency Paul trap for antiprotons. A system of 541 cast and extruded scintillator bars were arranged in 11 detector modules which provided a spatial resolution of 17 mm. Green wavelength-shifting fibers were embedded in the scintillators, and read out by silicon photomultipliers which had a sensitive area of 1 x 1 mm^2. The photoelectron yields of various scintillator configurations were measured using a negative pion beam of momentum p ~ 1 GeV/c. Various fibers and silicon photomultipliers, fiber end terminations, and couplings between the fibers and scintillators were compared. The detectors were also tested using the antiproton beam of the AD. Nonlinear effects due to the saturation of the silicon photomultiplier were seen a...

  1. Photomultiplier pulse Read Out system for the preshower detector of the LHCb experiment

    International Nuclear Information System (INIS)

    Ajaltouni, Z.; Bohner, G.; Cornat, R.; Deschamps, O.; Lecoq, J.; Monteil, S.; Perret, P.

    2003-01-01

    The second generation experiment for CP violation studies in B decays, LHCb, is a 20-m-long single-arm spectrometer to be installed on the future Large Hadron Collider at CERN. For its precision measurement purpose, it combines precise vertex location and particle identification, in addition to a performance trigger system able to cope with high flux. The first level of trigger is mainly based on the fast response of the calorimetric subsystem. Of major importance is the 6000 channels preshower detector that aims to validate the electromagnetic nature of calorimetric showers. It consists of two-radiation-length lead sheet in front of a scintillator plane. Scintillator signals are extracted from plastic cells using wavelength-shifting fibres coupled to multi-anode photomultiplier tubes. The preshower Read Out system has to cope with fluctuating photomultiplier pulses caused by small amounts of photoelectrons, in addition to strong constraints imposed by the 40 MHz LHC bunch-crossing frequency. A special Read Out electronics including perfect 40 MHz integrators able to shape fluctuating photomultiplier pulses has been designed, and successfully realized. The temporal shape of photomultiplier pulse and the upstream Read Out system for preshower are described in this document

  2. Precise analysis of the metal package photomultiplier single photoelectron spectra

    International Nuclear Information System (INIS)

    Chirikov-Zorin, I.E.; Fedorko, I.; Sykora, I.; Tokar, S.; Menzione, A.

    2000-01-01

    A deconvolution method based on a sophisticated photomultiplier response function was used to analyse the compact metal package photomultiplier spectra taken in single photoelectron mode. The spectra taken by Hamamtsu R5600 and R5900 photomultipliers have been analysed. The detailed analysis shows that the method appropriately describes the process of charge multiplication in these photomultipliers in a wide range of working regimes and the deconvoluted parameters are established with about 1% accuracy. The method can be used for a detailed analysis of photomultiplier noise and for calibration purposes

  3. GEM photomultiplier operation in CF sub 4

    CERN Document Server

    Breskin, Amos; Chechik, R

    2002-01-01

    The properties of a 3-GEM (Gas Electron Multiplier) element photomultiplier, with a semitransparent CsI photocathode and CF sub 4 gas filling, are presented. Compared to other gas mixtures, such as CH sub 4 , Ar/CH sub 4 , Ar/N sub 2 and He/Ar/N sub 2 , CF sub 4 has superior performance: the highest gain, approaching 10 sup 7 , the fastest, 8 ns wide signal and the lowest photoelectron backscattering; the latter allows to reach photocathode quantum efficiency values approaching that in vacuum. The time resolution of the multi-GEM photomultiplier for single photoelectrons was measured to be 2 ns. These properties are of high relevance for applications in Cherenkov detectors and in tracking devices.

  4. Silicon photomultiplier (SPM) detection of low-level bioluminescence for the development of deployable whole-cell biosensors: possibilities and limitations.

    Science.gov (United States)

    Li, Huaqing; Lopes, Nicholas; Moser, Scott; Sayler, Gary; Ripp, Steven

    2012-03-15

    Whole-cell bacterial bioreporters await miniaturized photon counting modules with high sensitivity and robust compatible hardware to fulfill their promise of versatile, on-site biosensor functionality. In this study, we explore the photon counting readout properties of the silicon photomultiplier (SPM) with a thermoelectric cooler and the possibilities of detecting low-level bioluminescent signals. Detection performance was evaluated through a simulated LED light source and the bioluminescence produced by the genetically engineered Pseudomonas fluorescens bacterial bioreporter 5RL. Compared with the conventional photomultiplier tube (PMT), the results revealed that the cooled SPM exhibits a wider linear response to inducible substrate concentrations (salicylate) ranging from 250 to 5000 ppb. Although cooling of the SPM lowered dark count rates and improved the minimum detectable signal, and the application of a digital filter enhanced the signal-to-noise ratio, the detection of very low light signals is still limited and remains a challenge in the design of compact photon counting systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Stability and lifetime testing of photomultiplier detectors for the Earth observing system SOLSTICE program

    Science.gov (United States)

    Hadler, Joshua A.; van de Kop, Toni; Drake, Virginia A.; McClintock, William E.; Murphy, John; Rodgers, Paul

    1998-10-01

    The primary objective of the Earth Observing System (EOS) Solar Stellar Irradiance Comparison Experiment (SOLSTICE) is to accurately measure the absolute value of the solar UV irradiance at the top of the earth's atmosphere for a minimum mission lifetime of 5 years. To meet this objective, SOLSTICE employs a unique design to determine changes in instrument performance by routinely observing a series of early-type stars and comparing the irradiances directly with the solar value. Although the comparison techniques allows us to track instrument performance, the success of the SOLSTICE experiment depends upon photomultiplier detectors which have graceful degradation properties. Therefore, we have established a laboratory program to evaluate the characteristics of photomultiplier tubes which are exposed to long term fluxes similar to those we expected to encounter in flight. Three types of Hamamatsu photomultiplier tubes were tested as candidates for use in the EOS-SOLSTICE project. The results of these studies: pulse height distribution; quantum efficiency; surface maps,; and lifetime analysis are presented in this paper.

  6. Portable X-ray fluorescence analyzer of high sensitivity using X-ray tube excitation

    International Nuclear Information System (INIS)

    Vatai, E.; Ando, L.

    1982-01-01

    A review of the three main methods of X-ray fluorescence analysis and their problems is given. The attainable accuracy and effectiveness of each method are discussed. The main properties of portable X-ray analyzers required by the industry are described. The results and experiences of R and D activities in ATOMKI (Debrecen, Hungary) for developing portable X-ray analyzers are presented. The only way for increasing the accuracy and decreasing the measuring time is the application of X-ray tube excitation instead of radioactive sources. The new ATOMKI equipment presently under construction and patenting uses X-ray tube excitation; it will increase the accuracy of concentration determination by one order of magnitude. (D.Gy.)

  7. Photomultiplier pulse Read Out system for the preshower detector of the LHCb experiment

    CERN Document Server

    Ajaltouni, Ziad J; Cornat, R; Deschamps, O; Lecoq, J; Monteil, S; Perret, P

    2003-01-01

    The second generation experiment for CP violation studies in B decays, LHCb, is a 20-m-long single-arm spectrometer to be installed on the future Large Hadron Collider at CERN. For its precision measurement purpose, it combines precise vertex location and particle identification, in addition to a performance trigger system able to cope with high flux. The first level of trigger is mainly based on the fast response of the calorimetric subsystem. Of major importance is the 6000 channels preshower detector that aims to validate the electromagnetic nature of calorimetric showers. It consists of two- radiation-length lead sheet in front of a scintillator plane. Scintillator signals are extracted from plastic cells using wavelength-shifting fibres coupled to multi-anode photomultiplier tubes. The preshower Read Out system has to cope with fluctuating photomultiplier pulses caused by small amounts of photoelectrons, in addition to strong constraints imposed by the 40 MHz LHC bunch- crossing frequency. A special Read...

  8. The Fabrication and Test of 64-Channel Silicon Photomultipliers

    Science.gov (United States)

    Lee, H. Y.; Jeon, Jin-A.; Park, Il H.; Lee, Jik

    2017-11-01

    A silicon photomultiplier (SiPM) is a highly sensitive photo sensor, and it consists of many micropixels that operated in Geiger mode. The SiPM has various preferable characteristics, such as low voltage operation compactness and lightweight. Additionally, the SiPM is robust and insensitive to magnetic fields, and it is capable of the counting of single photons due to the high gain of 105 ∼ 106. The developments of UV enhanced SiPMs and large area matrices of SiPMs have been actively pursued in the world. The technology can be utilized for applications such as radiation detection, medical science, cameras, and telescopes. In this study, we present the design, fabrication, and test result of the 64-channel SiPM sensor as the first step toward the development of a large matrix of SiPMs.

  9. Thermoregulation of silicon photomultipliers for space

    Energy Technology Data Exchange (ETDEWEB)

    Baldazzi, G.; Foschi, E. [Department of Physics and INFN, Viale B.Pichat 4/2, 40127 Bologna (Italy); Laurenti, G. [INFN of Bologna, Viale B.Pichat 4/2, 40127 Bologna (Italy); Levi, G. [Department of Physics and INFN, Viale B.Pichat 4/2, 40127 Bologna (Italy); Guandalini, C. [INFN of Bologna, Viale B.Pichat 4/2, 40127 Bologna (Italy); Lanconelli, N. [Department of Physics and INFN, Viale B.Pichat 4/2, 40127 Bologna (Italy); Quadrani, L. [INFN of Bologna, Viale B.Pichat 4/2, 40127 Bologna (Italy); Rossi, P. [Department of Physics and INFN, Viale B.Pichat 4/2, 40127 Bologna (Italy); Sbarra, C. [Department of Physics and INFN, Viale B.Pichat 4/2, 40127 Bologna (Italy); Enrico Fermi Research Center, Via Panisperna 89, 06100 Roma (Italy)], E-mail: cristina.sbarra@bo.infn.it; Zuffa, M. [INFN of Bologna, Viale B.Pichat 4/2, 40127 Bologna (Italy)

    2009-10-21

    The silicon photomultiplier (SiPM) has been recently studied in the INFN laboratories of Bologna for Time of Flight (TOF) detectors in space missions. Low consumption, low cost, low weight, resistance to radiation damage and insensitivity to magnetic fields are the advantages that lead to the choice of the SiPM to be used in conjunction with optical fibres for detecting the scintillation light of a space counter. The SiPM response to various light intensities has been studied in laboratory and it was compared to the PM response in order to use it for scintillation light instead of a photomultiplier. The results were confirmed by a Monte Carlo. Nevertheless the SiPM gain depends on temperature and thermal stabilization of the device turns out to be necessary. A hybrid front-end circuit that amplifies the signal while controlling and stabilizing the device temperature has been developed and some tests are shown. A thermal electric cooler (TEC) module based on Peltier cell has been modeled. The TEC module operating in atmosphere showed it can stabilize the temperature of the SiPM to the chosen set-point (9{+-}3 K) in a few seconds.

  10. A new VME-based high voltage power supply for large photomultiplier systems

    International Nuclear Information System (INIS)

    Neumaier, S.; Hubbeling, T.; Kolb, B.W.; Purschke, M.L.; Ippolitov, M.; Blume, C.; Bohne, E.M.; Bucher, D.; Claussen, A.; Peitzmann, T.; Schepers, G.; Schlagheck, H.

    1995-01-01

    We describe a new high voltage power supply, developed for the leadglass calorimeter of the WA98 experiment at CERN. The high voltage is produced for each of the 10,080 photomultiplier tubes of the detector individually, by the same number of active bases with on-board Greinacher voltage multipliers. The full VME-based HV controller system, which addresses each base via bus cables once per second, is miniaturized and fits into a single VME crate. The main advantages of this approach are the low heat dissipation, the considerably reduced amount of cabling and cost, as well as the high stability and low noise of the system. (orig.)

  11. Highly sensitive biosensing based on interference from light scattering in capillary tubes

    DEFF Research Database (Denmark)

    Sørensen, H.S.; Larsen, N.B.; Latham, J.C.

    2006-01-01

    with the affinity layer on the fused silica capillary. Within the framework of the model it is of paramount importance to establish a valid stop criterion for the infinite summations involved in the fringe pattern computations. The high sensitivity towards surface changes, ease of changing the surface chemistry...

  12. Sensitivity analysis of CFD code FLUENT-12 for supercritical water in vertical bare tubes

    Energy Technology Data Exchange (ETDEWEB)

    Farah, A.; Haines, P.; Harvel, G.; Pioro, I., E-mail: amjad.farah@yahoo.com, E-mail: patrickjhaines@gmail.com, E-mail: glenn.harvel@uoit.ca, E-mail: igor.pioro@uoit.ca [Univ. of Ontario Inst. of Technology, Faculty of Energy Systems and Nuclear Science,Oshawa, Ontario (Canada)

    2012-07-01

    The ability to use FLUENT 12 or other CFD software to accurately model supercritical water flow through various geometries in diabatic conditions is integral to research involving coal-fired power plants as well as Supercritical Water-cooled Reactors (SCWR). The cost and risk associated with constructing supercritical water test loops are far too great to use in a university setting. Previous work has shown that FLUENT 12, specifically realizable k-ε model, can reasonably predict the bulk and wall temperature distributions of externally heated vertical bare tubes for cases with relatively low heat and mass fluxes. However, sizeable errors were observed for other cases, often those which involved large heat fluxes that produce deteriorated heat transfer (DHT) regimes. The goal of this research is to gain a more complete understanding of how FLUENT 12 models supercritical water cases and where errors can be expected to occur. One control case is selected where expected changes in bulk and wall temperatures occur and they match empirical correlations' predictions, and the operating parameters are varied individually to gauge their effect on FLUENT's solution. The model used is the realizable k-ε, and the parameters altered are inlet pressure, mass flux, heat flux, and inlet temperature. (author)

  13. Photosynthesis in a test tube- dye sensitized solar cells as a teaching tool

    Energy Technology Data Exchange (ETDEWEB)

    Raturi, Atul; Fepuleai, Yoheni [Division of Physics, School of Engineering and Physics, The University of the South Pacific, Suva (Fiji)

    2010-05-15

    Dye sensitized solar cells employing natural plant dyes as phosensitizers can be effectively used to train students in the science and technology of solar cells. This is especially relevant to developing countries where facilities for silicon cell fabrication are non-existent. The cross-disciplinary nature of this device makes it very attractive for student projects. The present work describes such a project where anthocyanin dye from hibiscus flowers has been used as the electron harvester. (author)

  14. Tests of timing properties of silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Ronzhin, A.; Albrow, M.; /Fermilab; Byrum, K.; /Argonne; Demarteau, M.; Los, S.; /Fermilab; May, E.; /Argonne; Ramberg, A.; /Fermilab; Va' vra, J.; /SLAC; Zatserklyaniy, A.; /Puerto Rico U., Mayaguez

    2010-03-01

    Timing measurements of Silicon Photomultipliers (SiPM) [1] and [2] at the picosecond level were performed at Fermilab. The core timing resolution of the electronic measurement technique is approximately 2 ps. The single photoelectron time resolution (SPTR) was measured for the signals coming from the SiPM's. A SPTR of about one hundred picoseconds was obtained for SiPM's illuminated by laser pulses. The dependence of the SPTR on applied bias voltage and on the wavelength of the light was measured. A simple model is proposed to explain the difference in the SPTR for blue and red light. A time of flight system based on the SiPM's, with quartz Cherenkov radiators, was tested in a proton beam at Fermilab. The time resolution obtained is 35 ps per SiPM. Finally, requirements for the SiPM's temperature and bias voltage stability to maintain the time resolution are discussed.

  15. LYSO crystal calorimeter readout with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Berra, A., E-mail: alessandro.berra@gmail.com [Università degli Studi dell' Insubria (Italy); INFN sezione di Milano Bicocca (Italy); Bonvicini, V. [INFN sezione di Trieste (Italy); Cecchi, C.; Germani, S. [INFN sezione di Perugia (Italy); Guffanti, D. [Università degli Studi dell' Insubria (Italy); Lietti, D. [Università degli Studi dell' Insubria (Italy); INFN sezione di Milano Bicocca (Italy); Lubrano, P.; Manoni, E. [INFN sezione di Perugia (Italy); Prest, M. [Università degli Studi dell' Insubria (Italy); INFN sezione di Milano Bicocca (Italy); Rossi, A. [INFN sezione di Perugia (Italy); Vallazza, E. [INFN sezione di Trieste (Italy)

    2014-11-01

    Large area Silicon PhotoMultipliers (SiPMs) are the new frontier of the development of readout systems for scintillating detectors. A SiPM consists of a matrix of parallel-connected silicon micropixels operating in limited Geiger–Muller avalanche mode, and thus working as independent photon counters with a very high gain (∼10{sup 6}). This contribution presents the performance in terms of linearity and energy resolution of an electromagnetic homogeneous calorimeter composed of 9∼18X{sub 0} LYSO crystals. The crystals were readout by 36 4×4 mm{sup 2} SiPMs (4 for each crystal) produced by FBK-irst. This calorimeter was tested at the Beam Test Facility at the INFN laboratories in Frascati with a single- and multi-particle electron beam in the 100–500 MeV energy range.

  16. Muon tracking system with Silicon Photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Arneodo, F.; Benabderrahmane, M.L.; Dahal, S. [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Di Giovanni, A., E-mail: adriano.digiovanni@nyu.edu [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Pazos Clemens, L. [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Candela, A.; D' Incecco, M.; Sablone, D. [Gran Sasso National Laboratory of INFN, Assergi (Italy); Franchi, G. [AGE Scientific Srl, Capezzano Pianore (Italy)

    2015-11-01

    We report the characterisation and performance of a low cost muon tracking system consisting of plastic scintillator bars and Silicon Photomultipliers equipped with a customised front-end electronics based on a fast preamplifier network. This system can be used as a detector test bench for astroparticle physics and for educational and outreach purposes. We investigated the device behaviour in self-trigger and coincidence mode, without using LED and pulse generators, showing that with a relatively simple set up a complete characterisation work can be carried out. A high definition oscilloscope, which can easily be found in many university physics or engineering departments, has been used for triggering and data acquisition. Its capabilities have been exploited to discriminate real particles from the background.

  17. The γ rays sensitivity measurement of CeF3 scintillator detector

    International Nuclear Information System (INIS)

    Hu Mengchun; Zhou Dianzhong; Li Rurong; Wang Zhentong; Yang Hongqiong; Zhang Jianhua; Hu Qingyuan; Peng Taiping

    2003-01-01

    The CeF 3 is an abio-scintillator developed in recent years, which are insensitive to neutron and sensitive to gamma rays and respond quickness. The relationship of CeF 3 scintillation detector gamma rays sensitivity with the change of crystal thickness was measured. The CeF 3 scintillation detector is composed by high liner current photomultiplier tube of CHφT3, CHφT5 and CeF 3 scintillator. The detector gamma rays sensitivity of purple photocell and common photocell with CeF 3 scintillator were measured too

  18. Testing and simulation of silicon photomultiplier readouts for scintillators in high-energy astronomy and solar physics

    Science.gov (United States)

    Bloser, P. F.; Legere, J. S.; Bancroft, C. M.; Jablonski, L. F.; Wurtz, J. R.; Ertley, C. D.; McConnell, M. L.; Ryan, J. M.

    2014-11-01

    Space-based gamma-ray detectors for high-energy astronomy and solar physics face severe constraints on mass, volume, and power, and must endure harsh launch conditions and operating environments. Historically, such instruments have usually been based on scintillator materials due to their relatively low cost, inherent ruggedness, high stopping power, and radiation hardness. New scintillator materials, such as LaBr3:Ce, feature improved energy and timing performance, making them attractive for future astronomy and solar physics space missions in an era of tightly constrained budgets. Despite this promise, the use of scintillators in space remains constrained by the volume, mass, power, and fragility of the associated light readout device, typically a vacuum photomultiplier tube (PMT). In recent years, silicon photomultipliers (SiPMs) have emerged as promising alternative light readout devices that offer gains and quantum efficiencies similar to those of PMTs, but with greatly reduced mass and volume, high ruggedness, low voltage requirements, and no sensitivity to magnetic fields. In order for SiPMs to replace PMTs in space-based instruments, however, it must be shown that they can provide comparable performance, and that their inherent temperature sensitivity can be corrected for. To this end, we have performed extensive testing and modeling of a small gamma-ray spectrometer composed of a 6 mm×6 mm SiPM coupled to a 6 mm×6 mm ×10 mm LaBr3:Ce crystal. A custom readout board monitors the temperature and adjusts the bias voltage to compensate for gain variations. We record an energy resolution of 5.7% (FWHM) at 662 keV at room temperature. We have also performed simulations of the scintillation process and optical light collection using Geant4, and of the SiPM response using the GosSiP package. The simulated energy resolution is in good agreement with the data from 22 keV to 662 keV. Above ~1 MeV, however, the measured energy resolution is systematically worse than

  19. Novel approach based on one-tube nested PCR and a lateral flow strip for highly sensitive diagnosis of tuberculous meningitis.

    Science.gov (United States)

    Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui; Hu, Guohua

    2017-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation.

  20. Novel approach based on one-tube nested PCR and a lateral flow strip for highly sensitive diagnosis of tuberculous meningitis.

    Directory of Open Access Journals (Sweden)

    Yajuan Sun

    Full Text Available Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM, but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST, was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation.

  1. Time resolution performance studies of contemporary high speed photomultipliers

    International Nuclear Information System (INIS)

    Leskovar, B.; Lo, C.C.

    1977-01-01

    The time resolution capabilities of prototype microchannel plate and static crossed-field photomultipliers have been investigated. Measurements were made of electron transit time, rise time, time response, single photoelectron time spread and multiphotoelectron time spread for LEP HR350 proximity focused high gain curved microchannel plate and VPM-154A/1.6L static crossed-field photomultipliers. The experimental data have been compared with results obtained with conventionally designed RCS 8850 and C31024 high speed photomultipliers. Descriptions are given of both the measuring techniques and the measuring systems

  2. Sensitive determination of cadmium using solidified floating organic drop microextraction-slotted quartz tube-flame atomic absorption spectroscopy.

    Science.gov (United States)

    Akkaya, Erhan; Chormey, Dotse Selali; Bakırdere, Sezgin

    2017-09-20

    In this study, solidified floating organic drop microextraction (SFODME) by 1-undecanol was combined with slotted quartz tube flame atomic absorption spectrometry (SQT-FAAS) for the determination of cadmium at trace levels. Formation of a complex with 4,4'-dimethyl-2,2'-bipyridine facilitated the extraction of cadmium from aqueous solutions. Several chemical variables were optimized in order to obtain high extraction outputs. Parameters such as concentration of the ligand, pH, and amount of buffer solution were optimized to enhance the formation of cadmium complex. The SFODME method was assisted by dispersion of extractor solvent into aqueous solutions using 2-propanol. Under the optimum extraction and instrumental conditions, the limit of detection and limit of quantitation values obtained for cadmium using the combined methods (SFODME-SQT-FAAS) were found to be 0.4 and 1.3 μg L -1 , respectively. Matrix effects on the method were also examined for tap water and wastewater, and spiked recovery results were found to be very satisfactory. Graphical Abstract SFODME-SQT-FAAS system for sensitive determination of cadmium.

  3. Performance evaluation of neuro-PET using silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jiwoong; Choi, Yong, E-mail: ychoi@sogang.ac.kr; Jung, Jin Ho, E-mail: jinho1115@gmail.com; Kim, Sangsu; Im, Ki Chun

    2016-05-21

    Recently, we have developed the second prototype Silicon photomultiplier (SiPM) based positron emission tomography (PET) scanner for human brain imaging. The PET system was comprised of detector block which consisted of 4×4 SiPMs and 4×4 Lutetium Yttrium Orthosilicate arrays, charge signal transmission method, high density position decoder circuit and FPGA-embedded ADC boards. The purpose of this study was to evaluate the performance of the newly developed neuro-PET system. The energy resolution, timing resolution, spatial resolution, sensitivity, stability of the photo-peak position and count rate performance were measured. Tomographic image of 3D Hoffman brain phantom was also acquired to evaluate imaging capability of the neuro-PET. The average energy and timing resolutions measured for 511 keV gamma rays were 17±0.1% and 3±0.3 ns, respectively. Spatial resolution and sensitivity at the center of field of view (FOV) were 3.1 mm and 0.8%, respectively. The average scatter fraction was 0.4 with an energy window of 350–650 keV. The maximum true count rate and maximum NECR were measured as 43.3 kcps and 6.5 kcps at an activity concentration of 16.7 kBq/ml and 5.5 kBq/ml, respectively. Long-term stability results show that there was no significant change in the photo-peak position, energy resolution and count rate for 60 days. Phantom imaging studies were performed and they demonstrated the feasibility for high quality brain imaging. The performance tests and imaging results indicate that the newly developed PET is useful for brain imaging studies, if the axial FOV is extended to improve the system sensitivity.

  4. Influence of incident light wavelength on time jitter of fast photomultipliers

    International Nuclear Information System (INIS)

    Moszynski, M.; Vacher, J.

    1977-01-01

    The study of the single photoelectron time resolution as a function of the wavelength of the incident light was performed for a 56 CVP photomultiplier having an S-1 photocathode. The light flash from the XP22 light emitting diode generator was passed through passband filters and illuminated the 5 mm diameter central part of the photocathode. A significant increase of the time resolution above 30% was observed when the wavelength of the incident light was changed from 790 nm to 580 nm. This gives experimental evidence that the time jitter resulting from the spread of the initial velocity of photoelectrons is proportional to the square root of the maximal initial energy of photoelectrons. Based on this conclusion the measured time jitter of C31024, RCA8850 and XP2020 photomultipliers with the use of the XP22 light emitting diode at 560 nm light wavelength was recalculated to estimate the time jitter at 400 nm near the maximum of the photocathode sensitivity. It shows an almost twice larger time spread at 400 nm for the C31024 and RCA8850 with a high gain first dynode and an about 1.5 times larger time spread for the XP2020 photomultiplier, than those measured at 560 nm. (Auth.)

  5. UNCONTROLLED PHOTOMULTIPLIER CURRENT IN PHOTOEMISSION ANALYSIS

    Directory of Open Access Journals (Sweden)

    K. A. Viazava

    2016-01-01

    Full Text Available The dependence of photon energy from energy of photoelectron is base of photoemission radiation analysis. In such photoemission measurements except current of photocathode is always exist a reverse current from the collector of electrons to the photocathode in two-electrode sensors. There are various ways of reverse and uncontrolled current eliminating or reducing their influence. The constructive method is based on creating an electron-optical system of photoelectronic device, which would be a photoelectron energy analyzer. The second method – technological. However, it requires the manufacture of the photocathode and the dynode system in different vacuum chamber with subsequent connection to a single device in vacuum environment without exposure to the atmosphere. The purpose of this article is to determinate the effect of photoemission from photocathode chamber and the first dynode of photomultiplier on energy distribution of the photoelectrons from photocathode. To solve this problem authors obtained calibration curves for measuring pyrometer module ПИФ 4/2 with ФЭУ-114 as a sensor at supply voltage 1350 V and different decelerating voltages. The effect of illumination on the value of modulation coefficient on temperature k(T and wavelength k(λ is shown. In temperature measurements, this effect is evident in fact that at temperatures below 1400 K linear dependence ln k – T-1 is broken. Still this linear dependence is a necessary consequence of the fact that the measured temperature is color temperature. However, this calibration curve can be used to measure low temperature if the target measurements condition and calibration conditions are identical. In wavelength calibration, curve k(λ at λ > 760 nm is two-valued, that doesn’t allow to identify monochromatic radiation by this method and bring in errors in temperature measurements. 

  6. Radiation sensitive area detection device and method

    Science.gov (United States)

    Carter, Daniel C. (Inventor); Hecht, Diana L. (Inventor); Witherow, William K. (Inventor)

    1991-01-01

    A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

  7. Pulse shape discrimination performance of stilbene coupled to low-noise silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Ruch, Marc Lavi, E-mail: mruch@umich.edu; Flaska, Marek; Pozzi, Sara A

    2015-09-01

    Pulse shape discrimination (PSD) techniques can be used to discern between neutron and gamma-ray interactions in certain organic scintillators. Traditionally, photomultiplier tubes (PMTs) have been used in organic-scintillator assemblies. However, silicon photomultipliers (SiPMs) have great potential to be used in many applications in which PMTs have been predominantly used, including those utilizing PSD techniques. To evaluate the current state of the art of the SiPM technology, SensL's 6-mm B-Series and C-Series SiPMs were compared to a fast Hamamatsu PMT in conjunction with a 6×6×6-mm{sup 3} stilbene organic scintillator to assess the PSD performance of the detector assemblies. Measurements with a Cf-252 source were performed and a figure of merit (FOM) for discriminating between neutron and gamma-ray pulses between 100 keVee and 200 keVee was calculated for each assembly. A digital charge-integration PSD technique was used to process all measured data. The FOM for the B-Series SiPM, PMT, and C-Series SiPM was 1.37, 1.93, and 2.13, respectively. The C-Series SiPM was shown to perform as well as the PMT in the experiments. - Highlights: • Silicon photomultipliers show potential for use in applications that employ PMTs. • SensL C-Series SiPMs have 21% reduction in RMS noise compared to B-Series. • PSD using stilbene coupled to SiPM has improved significantly with low-noise SiPMs. • Such SiPMs can be used to perform PSD as well as PMTs using simple PSD algorithms.

  8. Application of nitrogen-doped TiO2 nano-tubes in dye-sensitized solar cells

    DEFF Research Database (Denmark)

    Tran, Vy Anh; Thinh Troung, Trieu; Pham Phan, Thu Anh

    2017-01-01

    Our research aimed to improve the overall energy conversion efficiency of DSCs by applying nitrogen-doped TiO2 nano-tubes (N-TNT) for the preparation of DSCs photo-anodes. The none-doped TiO2 nano-tubes (TNTs) were synthesized by alkaline hydrothermal treatment of Degussa P25 TiO2 particles in 10 M...

  9. Development of a Modern Cosmic Ray Telescope based on Silicon Photomultipliers for use in High Schools

    Science.gov (United States)

    Ruiz Castruita, Daniel; Niduaza, Rommel; Hernandez, Victor; Knox, Adrian; Ramos, Daniel; Fan, Sewan; Fatuzzo, Laura

    2015-04-01

    Lately, a new light sensor technology based on the breakdown phenomenon in the reverse biased silicon diode has found many applications that span from particle physics to medical imaging science. The silicon photomultiplier (SiPM) has several notable advantages compared to conventional photomultiplier tubes which include: lower cost, lower operating voltage and the ability to measure very weak light signals at the single photon level. At this conference meeting, we describe our efforts to implement SiPMs as read out light detectors for plastic scintillators in a cosmic ray telescope for use in high schools. In particular, we describe our work in designing, testing and assembling the cosmic ray telescope. We include a high gain preamplifier, a custom coincidence circuit using fast comparators to discriminate the SiPM signal amplitudes and a monovibrator IC for lengthening the singles and coincidence logic pulses. An Arduino micro-controller and program sketches are used for processing and storing the singles and coincidence counts data. Results from our measurements would be illustrated and presented. US Department of Education Title V Grant Award PO31S090007.

  10. CLARO: an ASIC for high rate single photon counting with multi-anode photomultipliers

    Science.gov (United States)

    Baszczyk, M.; Carniti, P.; Cassina, L.; Cotta Ramusino, A.; Dorosz, P.; Fiorini, M.; Gotti, C.; Kucewicz, W.; Malaguti, R.; Pessina, G.

    2017-08-01

    The CLARO is a radiation-hard 8-channel ASIC designed for single photon counting with multi-anode photomultiplier tubes. Each channel outputs a digital pulse when the input signal from the photomultiplier crosses a configurable threshold. The fast return to baseline, typically within 25 ns, and below 50 ns in all conditions, allows to count up to 107 hits/s on each channel, with a power consumption of about 1 mW per channel. The ASIC presented here is a much improved version of the first 4-channel prototype. The threshold can be precisely set in a wide range, between 30 ke- (5 fC) and 16 Me- (2.6 pC). The noise of the amplifier with a 10 pF input capacitance is 3.5 ke- (0.6 fC) RMS. All settings are stored in a 128-bit configuration and status register, protected against soft errors with triple modular redundancy. The paper describes the design of the ASIC at transistor-level, and demonstrates its performance on the test bench.

  11. Characterization and Optimization of silicon photomultipliers for the development of intraoperative beta probes

    Energy Technology Data Exchange (ETDEWEB)

    Hudin, N.; Pinot, L. [Laboratoire Imagerie et Modelisation en Neurobiologie et Cancerologie (UMR 8165), Campus d' Orsay, IN2P3-CNRS, 91406 Orsay Cedex (France); Dinu, N. [Laboratoire de l' Accelerateur Lineaire, IN2P3-CNRS, 91898 Orsay (France); Charon, Y. [Laboratoire Imagerie et Modelisation en Neurobiologie et Cancerologie (UMR 8165), Campus d' Orsay, IN2P3-CNRS, 91406 Orsay Cedex (France); Puill, V. [Laboratoire de l' Accelerateur Lineaire, IN2P3-CNRS, 91898 Orsay (France); Janvier, B. [Laboratoire Imagerie et Modelisation en Neurobiologie et Cancerologie (UMR 8165), Campus d' Orsay, IN2P3-CNRS, 91406 Orsay Cedex (France); Chaumat, V. [Laboratoire de l' Accelerateur Lineaire, IN2P3-CNRS, 91898 Orsay (France); Duval, M.-A.; Abi Haidar, D.; Siebert, R. [Laboratoire Imagerie et Modelisation en Neurobiologie et Cancerologie (UMR 8165), Campus d' Orsay, IN2P3-CNRS, 91406 Orsay Cedex (France); Menard, L., E-mail: menard@imnc.in2p3.fr [Laboratoire Imagerie et Modelisation en Neurobiologie et Cancerologie (UMR 8165), Campus d' Orsay, IN2P3-CNRS, 91406 Orsay Cedex (France)

    2012-12-11

    This work reports the results of a comprehensive study aiming to characterize and optimize the performances of Silicon Photomultipliers (SiPM) as photodetectors for intraoperative beta detection of radiolabeled tumor tissues. In that purpose, we focused our measurements on the influence of temperature and operating voltage on dark noise (count rate and amplitude distribution), absolute photon detection efficiency and total gain of different SiPM devices from Hamamatsu. The impact of these parameters on the overall beta sensitivity of SiPM-based scintillation detectors was quantified as a function of the intensity of the incident light following a simple physical model that is shown to correspond well with measurements.

  12. Reconstruction of scintillations coordinates in cylindrical large detector with radial arrangement of photomultipliers

    CERN Document Server

    Alekseev, V M; Verbitskij, V S; Verbitskij, S S; Lapik, M A; Tselebrovskij, A N; Lapik, A M; Rusakov, A V; Savopulo, M L; Smirnov, V V; Chubarov, M N

    2002-01-01

    Paper describes algorithm to calculate scintillation coordinates elaborated for a coordinate-sensitive large detector based on liquid scintillator with radial arrangement of nine FEU-174 photomultipliers. Paper contains the simulation results of coordinate resolution dependence in detector centre on energy of gamma-quanta within 0.2-8 MeV range. Using this algorithm one processed the experimental data obtained with application of sup 6 sup 0 Co gamma-radiation source and the results of determination of scintillation coordinates for gamma-quanta beam. The accuracy of coordinate determination in detector centre when applying the descried algorithm constitutes approx 10 mm

  13. GEM-based gaseous photomultipliers for UV and visible photon imaging

    International Nuclear Information System (INIS)

    Moermann, D.; Balcerzyk, M.; Breskin, A.; Chechik, R.; Singh, B.K.; Buzulutskov, A.

    2003-01-01

    We present the current status of our research on GEM-based gaseous photomultipliers. Detectors combining multi-GEM electron multipliers with semi-transparent and reflective photocathodes are discussed. We present recent progress in extending the sensitivity of these detectors into the visible range. We demonstrate the long-term stability of an argon-sealed bi-alkali photo-diode and provide preliminary results of a gas-sealed Kapton-GEM detector with a bi-alkali photocathode. The problem of ion-induced secondary electron emission is addressed

  14. Accuracy of single photoelectron time spread measurement of fast photomultipliers

    International Nuclear Information System (INIS)

    Leskovar, B.

    1975-01-01

    The accuracy of time spread measurements of fast photomultipliers was investigated, using single photoelectrons. The effect of the finite light pulse width on the measurement accuracy was determined and discussed. Experimental data were obtained on a special measuring system for light pulse widths ranging from 200 psec to 10 nsec, using fast photomultipliers 8850 and C31024 with optimized operating conditions for minimum transit time spread. A modified exponential function expression and curve-fitting parameters are given, which fit closely the experimentally obtained data over a wide dynamic range of light pulse widths. (U.S.)

  15. Experimental study of non-linear effects on photomultiplier gain

    International Nuclear Information System (INIS)

    De Vincenzi, M.; Penso, G.; Sciubba, A.; Sposito, A.

    1984-01-01

    The experimental apparatus and the results of a study on the gain variation of photomultipliers at high average anode current are described. This gain variation was found to depend on the secondary emission process on dynodes; the last dynode gives the largest contribution to the overall photomultiplier effect. This contribution has been isolated and measured. The phenomenon may be due to more than one physical effect. The dominant one turns out to depend on the power released on the dynode by the incident electrons. A physical model is discussed which can take into account the observed phenomena. (orig.)

  16. Two types of photomultiplier voltage dividers for high and changing count rates

    International Nuclear Information System (INIS)

    Reiter, W.L.; Stengl, G.

    1980-01-01

    We report on the design of two types of voltage distribution circuits for high stability photomultiplier operation. 'Type A' voltage divider is an ohmic voltage divider with high bleeder current (up to 10 mA) and the resistor chain split at one of the last dynodes, usually the dynode where the analog signal is derived from. This simple constructive measure improves the stability of the dynode voltage by a factor of 5 compared with an unsplit conventional resistor chain. 'Type B' is a novel active voltage divider using cold cathode tubes ar regulating elements. This voltage divider exhibits excellent temperature stability (about 10 -4 / 0 C). With 'type B' an equal stability compared with conventional ohmic dividers can be achieved at a bleeder current smaller by one order of magnitude. Of course both concepts, 'type A' and 'type B', can be combined. (orig.)

  17. APPLICATION OF MULTILAYER FILM CONFIGURATION TO PROTECT PHOTOMULTIPLIER AGAINST EXTERNAL STATIC MAGNETIC FIELDS

    Directory of Open Access Journals (Sweden)

    A. G. Batische

    2012-01-01

    Full Text Available The effectiveness of the screening constant magnetic field is multi-layered film screens system of NiFe/Cu, formed on the cylindrical housing of photomultiplier tubes, and compared with screen-based steel material – brand 80NHS permalloy. It is shown that the most effective is the screen on the basis of the multilayered film screens, which provide shielding effectiveness value 8–10 in magnetic fields with induction of 0,1–1 mT, and 80–100 – in magnetic fields with induction of 2–4 mT , which is 4–5 times higher than for the screen of the material 80NHS.

  18. Counting efficiency formulae for two, three or four photomultiplier systems

    International Nuclear Information System (INIS)

    Grau Malonda, A.

    1993-01-01

    Counting efficiency formulae as a function of the non-detection probability and the electron distributions for systems with two, three or dour photomultipliers are obtained in this paper. It is assumed that the photocathode electron emission follows the Poisson distribution. The obtained formulae are basic to compute the counting efficiency in liquid scintillation spectrometers

  19. Timing optimization utilizing order statistics and multichannel digital silicon photomultipliers

    NARCIS (Netherlands)

    Mandai, S.; Venialgo, E.; Charbon, E.

    2014-01-01

    We present an optimization technique utilizing order statistics with a multichannel digital silicon photomultiplier (MD-SiPM) for timing measurements. Accurate timing measurements are required by 3D rangefinding and time-of-flight positron emission tomography, to name a few applications. We have

  20. Hybrid photomultipliers - their properties and application in scintillation studies

    Czech Academy of Sciences Publication Activity Database

    Mareš, Jiří A.; D'Ambrosio, C.

    2007-01-01

    Roč. 30, - (2007), s. 22-25 ISSN 0925-3467 Institutional research plan: CEZ:AV0Z10100521 Keywords : hybrid photodetection and photomultiplier * PIN silicon * pulse- height spectra Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.519, year: 2007

  1. Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers

    Science.gov (United States)

    Kwon, Sun Il; Ferri, Alessandro; Gola, Alberto; Berg, Eric; Piemonte, Claudio; Cherry, Simon R.; Roncali, Emilie

    2016-01-01

    Abstract. Current research in the field of positron emission tomography (PET) focuses on improving the sensitivity of the scanner with thicker detectors, extended axial field-of-view, and time-of-flight (TOF) capability. These create the need for depth-of-interaction (DOI) encoding to correct parallax errors. We have proposed a method to encode DOI using phosphor-coated crystals. Our initial work using photomultiplier tubes (PMTs) demonstrated the possibilities of the proposed method, however, a major limitation of PMTs for this application is poor quantum efficiency in yellow light, corresponding to the wavelengths of the converted light by the phosphor coating. In contrast, the red-green-blue-high-density (RGB-HD) silicon photomultipliers (SiPMs) have a high photon detection efficiency across the visible spectrum. Excellent coincidence resolving time (CRT; <210  ps) was obtained by coupling RGB-HD SiPMs and  3 × 3 × 20  mm3 lutetium fine silicate crystals coated on a third of one of their lateral sides. Events were classified in three DOI bins (∼6.7-mm width) with an average sensitivity of 83.1%. A CRT of ∼200  ps combined with robust DOI encoding is a marked improvement in the phosphor-coated approach that we pioneered. For the first time, we read out these crystals with SiPMs and clearly demonstrated the potential of the RGB-HD SiPMs for this TOF-DOI PET detector. PMID:27921069

  2. Application of nitrogen-doped TiO{sub 2} nano-tubes in dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Tran, Vy Anh; Truong, Trieu Thinh; Phan, Thu Anh Pham; Nguyen, Trang Ngoc [Faculty of Chemistry, University of Science, Vietnam National University, Ho Chi Minh City (Viet Nam); Huynh, Tuan Van [Faculty of Physics and Engineering Physics, University of Science, Vietnam National University, Ho Chi Minh City (Viet Nam); Agresti, Antonio; Pescetelli, Sara [CHOSE (Centre for Hybrid and Organic Solar Energy), Department of Electronic Engineering, University of Rome Tor Vergata (Italy); Le, Tien Khoa [Faculty of Chemistry, University of Science, Vietnam National University, Ho Chi Minh City (Viet Nam); Di Carlo, Aldo [CHOSE (Centre for Hybrid and Organic Solar Energy), Department of Electronic Engineering, University of Rome Tor Vergata (Italy); Lund, Torben [Department of Science and Environment, Roskilde University, DK-4000 (Denmark); Le, So-Nhu [Faculty of Chemistry, University of Science, Vietnam National University, Ho Chi Minh City (Viet Nam); Nguyen, Phuong Tuyet, E-mail: ngtuyetphuong@gmail.com [Faculty of Chemistry, University of Science, Vietnam National University, Ho Chi Minh City (Viet Nam)

    2017-03-31

    Highlights: • N-doped TiO{sub 2} nanotubes are synthesized by alkaline hydrothermal and reflux method. • Formation of TiO{sub 2} nanotube morphology and anatase phase is shown by TEM, XRD, Raman. • Coordination of NH{sub 4}{sup +} via Ti−O−NH{sub 4}{sup +} or H{sub 4}N{sup +}−Ti−O bonds is indicated by FT-IR and XPS. • Blocking effect of N-doped toward electron transfer on TiO{sub 2} anode is studied by CV. • N-doped TiO{sub 2} improved DSC performance up to 30–40% mainly due to an increase in J{sub sc}. - Abstract: Our research aimed to improve the overall energy conversion efficiency of DSCs by applying nitrogen-doped TiO{sub 2} nano-tubes (N-TNT) for the preparation of DSCs photo-anodes. The none-doped TiO{sub 2} nano-tubes (TNTs) were synthesized by alkaline hydrothermal treatment of Degussa P25 TiO{sub 2} particles in 10 M NaOH. The nano-tubes were N-doped by reflux in various concentrations of NH{sub 4}NO{sub 3}. The effects of nitrogen doping on the structure, morphology, and crystallography of N-TNT were analyzed by transmission electron microscopy (TEM), infrared spectroscopy (IR), Raman spectroscopy, and X-ray photoelectron spectra (XPS). DSCs fabricated with doped N-TNT and TNT was characterized by J-V measurements. Results showed that nitrogen doping significantly enhanced the efficiency of N-TNT cells, reaching the optimum value (η = 7.36%) with 2 M nitrogen dopant, compared to η = 4.75% of TNT cells. The high efficiency of the N-TNT cells was attributed to increased current density due to the reduction of dark current in the DSCs.

  3. The development of a high-resolution scintillating fiber tracker with silicon photomultiplier readout

    International Nuclear Information System (INIS)

    Roper Yearwood, Gregorio

    2013-01-01

    In this work I present the design and test results for a novel, modular tracking detector from scintillating fibers which are read out by silicon photomultiplier (SiPM) arrays. The detector modules consist of 0.25 mm thin scintillating fibers which are closely packed in five-layer ribbons. Two ribbons are fixed to both sides of a carbon-fiber composite structure. Custom made SiPM arrays with a photo-detection efficiency of about 50% read out the fibers. Several 860 mm long and 32 mm wide tracker modules were tested in a secondary 12 GeV/c beam at the PS facilities, CERN in November of 2009. During this test a spatial resolution better than 0.05 mm at an average light yield of about 20 photons for a minimum ionizing particle was determined. This work details the characterization of scintillating fibers and silicon photomultipliers of different make and model. It gives an overview of the production of scintillating fiber modules. The behavior of detector modules during the test-beam is analyzed in detail and different options for the front-end electronics are compared. Furthermore, the implementation of the proposed tracking detector from scintillating fibers within the scope of the PERDaix experiment is discussed. The PERDaix detector is a permanent magnet spectrometer with a weight of 40 kg. It consists of 8 tracking detector layers from scintillating fibers, a time-of-flight detector from plastic scintillator bars with silicon photomultiplier readout and a transition radiation detector from an irregular fleece radiator and Xe/CO 2 filled proportional counting tubes. The PERDaix detector was launched with a helium balloon within the scope of the ''Balloon-Experiments for University Students'' (BEXUS) program from Kiruna, Sweden in November 2010. For a few hours PERDaix reached an altitude of 33 km and measured cosmic rays. In May 2011, the PERDaix detector was characterized during a test-beam at the PS-facilities at CERN. This work introduces methods for event

  4. Characterization of a prototype matrix of Silicon PhotoMultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Dinu, N. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France)], E-mail: dinu@lal.in2p3.fr; Barrillon, P.; Bazin, C. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Belcari, N.; Bisogni, M.G. [Universita di Pisa, Dipartimento di Fisica ' E. Fermi' , 56127 Pisa (Italy); INFN, Sezione di Pisa, 56127 Pisa (Italy); Bondil-Blin, S. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Boscardin, M. [Fondazione Bruno Kessler (FBK-irst), 38050 Trento (Italy); Chaumat, V. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Collazuol, G. [Scuola Normale Superiore (SNS), 56127 Pisa (Italy); INFN, Sezione di Pisa, 56127 Pisa (Italy); De La Taille, C. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Del Guerra, A. [Universita di Pisa, Dipartimento di Fisica ' E. Fermi' , 56127 Pisa (Italy); INFN, Sezione di Pisa, 56127 Pisa (Italy); Llosa, G. [Universita di Pisa, Dipartimento di Fisica ' E. Fermi' , 56127 Pisa (Italy); Marcatili, S. [Universita di Pisa, Dipartimento di Fisica ' E. Fermi' , 56127 Pisa (Italy); INFN, Sezione di Pisa, 56127 Pisa (Italy); Melchiorri, M.; Piemonte, C. [Fondazione Bruno Kessler (FBK-irst), 38050 Trento (Italy); Puill, V. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Tarolli, A. [Fondazione Bruno Kessler (FBK-irst), 38050 Trento (Italy); Vagnucci, J.F. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Zorzi, N. [Fondazione Bruno Kessler (FBK-irst), 38050 Trento (Italy)

    2009-10-21

    This work reports on the electrical as well as the optical characterizations of a prototype matrix of Silicon PhotoMultipliers (SiPM). The electrical test consists of the measurement of the static (breakdown voltage, quenching resistance, post-breakdown dark current) as well as the dynamic characteristics (gain, dark count rate). The optical test consists of the estimation of the photon detection efficiency as a function of wavelength as well as operation voltage.

  5. Characterization of a prototype matrix of Silicon PhotoMultipliers

    International Nuclear Information System (INIS)

    Dinu, N.; Barrillon, P.; Bazin, C.; Belcari, N.; Bisogni, M.G.; Bondil-Blin, S.; Boscardin, M.; Chaumat, V.; Collazuol, G.; De La Taille, C.; Del Guerra, A.; Llosa, G.; Marcatili, S.; Melchiorri, M.; Piemonte, C.; Puill, V.; Tarolli, A.; Vagnucci, J.F.; Zorzi, N.

    2009-01-01

    This work reports on the electrical as well as the optical characterizations of a prototype matrix of Silicon PhotoMultipliers (SiPM). The electrical test consists of the measurement of the static (breakdown voltage, quenching resistance, post-breakdown dark current) as well as the dynamic characteristics (gain, dark count rate). The optical test consists of the estimation of the photon detection efficiency as a function of wavelength as well as operation voltage.

  6. Dynamic range broadening for photomultipliers in kinetic spectrophotometry

    International Nuclear Information System (INIS)

    Rumas, V.K.

    1983-01-01

    The circuit of switching on a photomultiplier with prestage modulation developed for kinetic spectrophotometry purposes is described. Distinguishing features of the scheme are wide range of control pulse duration (40 nc - 2.5 mc) and direct transistor photostart by laser light pulse. In the case of PM prestage modulation for the second dynode modulation depth attains 400 while PM opening time constitutes 40 nc

  7. Large-area CMOS solid-state photomultipliers and recent developments

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Erik B., E-mail: ejohnson@rmdinc.com [Radiation Monitoring Devices, Inc., 44 Hunt Street, Watertown, MA 02472 (United States); Stapels, Christopher J.; Xiao Jiechen [Radiation Monitoring Devices, Inc., 44 Hunt Street, Watertown, MA 02472 (United States); Augustine, Frank L. [Augustine Engineering, 2115 Park Dale Lane, Encinitas, CA 92024 (United States); Christian, James F. [Radiation Monitoring Devices, Inc., 44 Hunt Street, Watertown, MA 02472 (United States)

    2011-10-01

    The CMOS solid-state photomultiplier (SSPM) is an array of Geiger avalanche photodiodes (GPD) read out in parallel. These devices are not susceptible to magnetic fields, less expensive to fabricate than many other photodetector technologies, compact, and allow for on-chip integration of signal processing circuits. A number of nuclear detection applications require detector sizes on the order of 1 cm. Standard silicon fabrication technology limits the size of the SSPM die, and tiling of the silicon die can result in large-area devices but results in dead space between die for bonding purposes. Radiation Monitoring Devices (RMD) has fabricated 1x1 cm SSPM arrays on a single die. The size of these devices is large enough to provide an alternative detector for scintillation detector applications compared to photomultiplier tubes. Although the size increases the dark noise, we will demonstrate that the large-area SSPM can provide a PMT-like response for {sup 22}Na gamma rays using an LYSO crystal. Each of the noise terms associated with the large-area SSPM is discussed, quantifying the cross talk and after pulse multipliers, which are scaling factors to the gain to account for the additional output charge from the SSPM. The excess noise factor associated with cross talk and after pulsing has a linear dependence on the multiplier term. The signal and noise terms have been compiled to provide the best operating voltage of roughly 6 V above breakdown for a 1x1 cm CMOS SSPM to be operated with a short integration time (<10 ns) and at 0 deg. C.

  8. A novel and highly sensitive real-time nested RT-PCR assay in a single closed tube for detection of enterovirus.

    Science.gov (United States)

    Shen, Xin-Xin; Qiu, Fang-Zhou; Zhao, Huai-Long; Yang, Meng-Jie; Hong, Liu; Xu, Song-Tao; Zhou, Shuai-Feng; Li, Gui-Xia; Feng, Zhi-Shan; Ma, Xue-Jun

    2018-03-01

    The sensitivity of qRT-PCR assay is not adequate for the detection of the samples with lower viral load, particularly in the cerebrospinal fluid (CSF) of patients. Here, we present the development of a highly sensitive real-time nested RT-PCR (RTN RT-PCR) assay in a single closed tube for detection of human enterovirus (HEV). The clinical performance of both RTN RT-PCR and qRT-PCR was also tested and compared using 140 CSF and fecal specimens. The sensitivities of RTN RT-PCR assay for EV71, Coxsackievirus A (CVA)16, CVA6 and CVA10 achieved 10 -8 dilution with a corresponding Ct value of 38.20, 36.45, 36.75, and 36.45, respectively, which is equal to traditional two-step nested RT-PCR assay and approximately 2-10-fold lower than that of qRT-PCR assay. The specificity of RTN RT-PCR assay was extensively analyzed insilico and subsequently verified using the reference isolates and clinical samples. Sixteen qRT-PCR-negative samples were detected by RTN RT-PCR and a variety of enterovirus serotypes was identified by sequencing of inner PCR products. We conclude RTN RT-PCR is more sensitive than qRT-PCR for the detection of HEV in clinical samples. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for μSR measurements on a continuous-wave beam.

    Science.gov (United States)

    Amato, A; Luetkens, H; Sedlak, K; Stoykov, A; Scheuermann, R; Elender, M; Raselli, A; Graf, D

    2017-09-01

    We report on the design and commissioning of a new spectrometer for muon-spin relaxation/rotation studies installed at the Swiss Muon Source (SμS) of the Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially a new design and replaces the old general-purpose surface-muon (GPS) instrument that has been for long the workhorse of the μSR user facility at PSI. By making use of muon and positron detectors made of plastic scintillators read out by silicon photomultipliers, a time resolution of the complete instrument of about 160 ps (standard deviation) could be achieved. In addition, the absence of light guides, which are needed in traditionally built μSR instrument to deliver the scintillation light to photomultiplier tubes located outside magnetic fields applied, allowed us to design a compact instrument with a detector set covering an increased solid angle compared with the old GPS.

  10. Development and Validation of a Sensitive Method for Trace Nickel Determination by Slotted Quartz Tube Flame Atomic Absorption Spectrometry After Dispersive Liquid-Liquid Microextraction.

    Science.gov (United States)

    Yolcu, Şükran Melda; Fırat, Merve; Chormey, Dotse Selali; Büyükpınar, Çağdaş; Turak, Fatma; Bakırdere, Sezgin

    2018-05-01

    In this study, dispersive liquid-liquid microextraction was systematically optimized for the preconcentration of nickel after forming a complex with diphenylcarbazone. The measurement output of the flame atomic absorption spectrometer was further enhanced by fitting a custom-cut slotted quartz tube to the flame burner head. The extraction method increased the amount of nickel reaching the flame and the slotted quartz tube increased the residence time of nickel atoms in the flame to record higher absorbance. Two methods combined to give about 90 fold enhancement in sensitivity over the conventional flame atomic absorption spectrometry. The optimized method was applicable over a wide linear concentration range, and it gave a detection limit of 2.1 µg L -1 . Low relative standard deviations at the lowest concentration in the linear calibration plot indicated high precision for both extraction process and instrumental measurements. A coal fly ash standard reference material (SRM 1633c) was used to determine the accuracy of the method, and experimented results were compatible with the certified value. Spiked recovery tests were also used to validate the applicability of the method.

  11. Dynamics of tubes in fluid with tube-baffle interaction

    International Nuclear Information System (INIS)

    Chen, S.S.; Jendrzejczyk, J.A.; Wambsganss, M.W.

    1983-09-01

    Three series of tests are performed to evaluate the effects of tube to tube-support-plate (TSP) clearance on tube dynamic characteristics and instability phenomena for tube arrays in crossflow. Test results show that, for relatively large clearances, tubes may possess TSP-inactive modes in which the tubes rattle inside some of the tube-support-plate holes, and that the natural frequencies of TSP-inactive modes are lower than those of TSP-active modes, in which the support plates provide knife-edge type support. Tube response characteristics associated with TSP-inactive modes are sensitive to tube-to-TSP clearance, TSP thickness, excitation amplitude, tube alignment, and the fluid inside the clearance. In addition, tube response is intrinsically nonlinear, with the dominance of TSP-inactive or TSP-active modes depending on the magnitudes of different system parameters. In general, such a system is difficult to model; only a full-scale test can provide all the necessary characteristics. A tube array supported by TSPs with relatively large clearances may be subjected to dynamic instability in some of the TSP-inactive modes; tube response characteristics and impact forces on TSPs for a tube row are studied in detail in this report. Tube displacements associated with the instability of a TSP-inactive mode are small; however, impacts of the tube against TSPs may result in significant damage in a relatively short time. 52 figures

  12. Characterization and optimization of Silicon Photomultipliers and small size scintillator tiles for future calorimeter applications

    CERN Document Server

    AUTHOR|(CDS)2095312; Horváth, Ákos

    For the active layers of highly granular sampling calorimeters, small scintillator tiles read out by Silicon Photomultipliers (SiPM) can be an interesting and cost effective alternative to silicon sensors. At CERN a test setup was realized for the development of new generations of calorimeters to characterize new types of Silicon Photomultipliers in terms of gain, noise, afterpulses and crosstalk and to study the impact of scintillator wrappings and the tile size on the measured light yield and uniformity. In this thesis work, the experimental setup is described and the steps for commissioning the equipment are discussed. Then, the temperature dependence of the Silicon Photomultiplier response will be investigated, including the dependence of bare Silicon Photomultipliers as well as Silicon Photomultipliers coupled to scintillator tiles. Finally, the tile-photomultiplier response for different tile sizes and coating options will be evaluated. The experimental setup will be extended to allow for the characteri...

  13. Time-Domain Functional Diffuse Optical Tomography System Based on Fiber-Free Silicon Photomultipliers

    Directory of Open Access Journals (Sweden)

    Andrea Farina

    2017-11-01

    Full Text Available Based on recent developments in both single-photon detectors and timing electronic circuits, we designed a compact and cost effective time-domain diffuse optical tomography system operated at 1 Hz acquisition rate, based on eight silicon photomultipliers and an 8-channel time-to-digital converter. The compact detectors are directly hosted on the probe in a circular arrangement around a single light injection fiber, so to maximize light harvesting. Tomography is achieved exploiting the depth sensitivity that is encoded in the arrival time of detected photons. The system performances were evaluated on simulations to assess possible the limitations arising from the use of a single injection point, and then on phantoms and in vivo to prove the eligibility of these technologies for diffuse optical tomography.

  14. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellermann, E.W.; Bateman, J.E.; Connolly, J.F.

    1978-03-01

    The properties of a prototype gas proportional scintillation detector, for use in large numbers, are examined. The detector is designed to focus a light signal, which is proportional to ionisation loss, into a fibre optic lightguide. It is shown that a single charged particle traversing the detector produces enough light out of the lightguide to be seen by a TV camera. Problems of lifetime and large scale detector production are discussed. Properties of saturation, linearity, position sensitivity, and operating limits are examined. It is shown that an array of gas proportional scintillation detectors when used with fibre optic lightguides and TV camera readout could offer significant improvements in cost per area and reliability over a scintillator plus photomultiplier or a wire proportional chamber array. (author)

  15. Study of a high gain microchannel plate photomultiplier having low statistical gain fluctuations

    International Nuclear Information System (INIS)

    Audier, M.

    1980-12-01

    A new photomultiplier configuration which synthesizes the performances of several models is proposed. The principles of microchannel plate photomultipliers are reviewed. The physical phenomena which limit the electron multiplication process in a microchannel and the detection efficiency of the microchannel plates are investigated. The operation of a herring-bone pattern device and of a system of two microchannel plate photomultipliers are described and characterized [fr

  16. Sensitivity Analysis of Dousing Spray Trip on Radioactive Release in Pressure Tube Rupture Accident with Both End Fitting Failures

    Energy Technology Data Exchange (ETDEWEB)

    Jang, M. S.; Kang, H. S; Kim, S. R. [NESS, Daejeon (Korea, Republic of)

    2015-10-15

    We analyzed the sensitivity analysis of dousing spray trip conditions on radioactive release. In terms of conservativeness, the set 1 trip would be more appropriate in RR analysis than set 2 trip, which is the general condition of RR analysis. Radioactive releases from the containment building is related to containment air pressure, which increases by the coolant discharge from loss of coolant accident and the actuation conditions of dousing spray and so on. In LOCA analysis, the dousing spray trip conditions are set for the analysis objectives; for peak pressure (PP), for pressure signal (PS), for radioactive release (RR) and etc. In RR analysis, we would determine the dousing spray trip condition to increase radioactive release to the public for conservatism. Therefore, we carried out the sensitivity analysis of dousing spray trip condition on radioactive release from containment building using GOTHIC and SMART program for CANDU.

  17. Feeding Tubes

    Science.gov (United States)

    ... the TPN. Tubes Used for Enteral Feeds NG (Nasogastric Tube) A flexible tube is placed via the nose, ... portion of the small intestine Naso – nose NG – Nasogastric Tube -ostomy – new opening Percutaneous – through the skin PEJ – ...

  18. Rapid and sensitive detection of canine distemper virus by one-tube reverse transcription-insulated isothermal polymerase chain reaction.

    Science.gov (United States)

    Wilkes, Rebecca P; Tsai, Yun-Long; Lee, Pei-Yu; Lee, Fu-Chun; Chang, Hsiao-Fen Grace; Wang, Hwa-Tang Thomas

    2014-09-09

    Canine distemper virus (CDV) has been associated with outbreaks of canine infectious respiratory disease in shelters and boarding kennel environments. POCKITTM Nucleic Acid Analyzer is a field-deployable device capable of generating automatically interpreted insulated isothermal polymerase chain reaction (iiPCR) results from extracted nucleic acid within one hour. In this study, reverse transcription iiPCR (RT-iiPCR) was developed to facilitate point-of-need diagnosis of CDV infection. Analytical sensitivity (limit of detection 95%) of the established CDV RT-iiPCR was about 11 copies of in vitro transcribed RNA per reaction. CDV RT-iiPCR generated positive signals from CDV, but not Bordetella bronchiseptica, canine parvovirus, canine herpesvirus, canine adenovirus 2, canine influenza virus (subtype H3N8), canine parainfluenza virus, and canine respiratory coronavirus. To evaluate accuracy of the established reaction in canine distemper clinical diagnosis, 110 specimens from dogs, raccoons, and foxes suspected with CDV infection were tested simultaneously by CDV RT-iiPCR and real-time RT-PCR. CDV RT-iiPCR demonstrated excellent sensitivity (100%) and specificity (100%), compared to real-time RT-PCR. The results indicated an excellent correlation between RT-iiPCR and a reference real time RT-PCR method. Working in a lyophilized format, the established method has great potential to be used for point-of-care diagnosis of canine distemper in animals, especially in resource-limited facilities.

  19. Precision analysis of the photomultiplier response to ultra low signals

    Science.gov (United States)

    Degtiarenko, Pavel

    2017-11-01

    A new computational model for the description of the photon detector response functions measured in conditions of low light is presented, together with examples of the observed photomultiplier signal amplitude distributions, successfully described using the parameterized model equation. In extension to the previously known approximations, the new model describes the underlying discrete statistical behavior of the photoelectron cascade multiplication processes in photon detectors with complex non-uniform gain structure of the first dynode. Important features of the model include the ability to represent the true single-photoelectron spectra from different photomultipliers with a variety of parameterized shapes, reflecting the variability in the design and in the individual parameters of the detectors. The new software tool is available for evaluation of the detectors' performance, response, and efficiency parameters that may be used in various applications including the ultra low background experiments such as the searches for Dark Matter and rare decays, underground neutrino studies, optimizing operations of the Cherenkov light detectors, help in the detector selection procedures, and in the experiment simulations.

  20. Investigating the baselines of Bismuth, Optical Fiber and LED calibrated photomultiplier tubes

    CERN Document Server

    Evans, Hywel Turner

    2016-01-01

    LUCID is a detector that is the luminosity monitor for the ATLAS experiment, and its aim is to determine luminosity with an uncertainty of a few percent. The main purpose of this work is the study of the baseline stability of the LUCID readout channels during calibration runs. This study represents the first systematic approach of this problem performed by the LUCID group. By replacing the mean baseline with the minimum baseline of each event, an upper limit of 2.85% was placed upon possible improvement in determining the LED amplitude. It is therefore better to use a fixed baseline for LED, as pollution has been observed when calculating event by event. For Bismuth and Fiber, the improvement cannot be more than the gain stability of 1%, therefore the existing method is verified as optimal.

  1. A high speed digitizing photomultiplier tube base for the KTeV CsI calorimeter

    International Nuclear Information System (INIS)

    Whitmore, J.

    1994-11-01

    A circuit has been designed to digitize PMT signals over an 18-bit dynamic range with 8-bits of resolution. The crucial element of the circuit is the custom charge integrating and encoding (QIE) ASIC. This chip is designed to operate at rates up to 53 MHz, and, in conjunction with an 8-bit FADC, generates 12-bit floating point output. Bench tests of a 17-bit version of the digital base demonstrated excellent noise performance, linearity and pedestal and gain stability. Twenty-five channels of digitizing PMT bases have been built and used for readout of a CsI array in a test beam at CERN. Performance of these devices in a beam environment is discussed

  2. Study of various photomultiplier tubes with muon beams and Cerenkov light produced in electron showers

    International Nuclear Information System (INIS)

    2010-01-01

    The PMTs of the CMS Hadron Forward calorimeter were found to generate a large size signal when their windows were traversed by energetic charged particles. This signal, which is due to Cerenkov light production at the PMT window, could interfere with the calorimeter signal and mislead the measurements. In order to find a viable solution to this problem, the response of four different types of PMTs to muons traversing their windows at different orientations is measured at the H2 beam-line at CERN. Certain kinds of PMTs with thinner windows show significantly lower response to direct muon incidence. For the four anode PMT, a simple and powerful algorithm to identify such events and recover the PMT signal using the signals of the quadrants without window hits is also presented. For the measurement of PMT responses to Cerenkov light, the Hadron Forward calorimeter signal was mimicked by two different setups in electron beams and the PMT performances were compared with each other. Superior performance of particular PMTs was observed.

  3. LHCb : Behaviour of Multi-anode Photomultipliers in Magnetic Fields for the LHCb RICH Upgrde

    CERN Multimedia

    Gambetta, Silvia

    2015-01-01

    A key feature of the LHCb upgrade, scheduled for 2019, is to remove the first level trigger and its data reduction from 40MHz to 1MHz, which is implemented in the on-detector readout electronics. The consequence for the LHCb Ring Imaging Cherenkov (RICH) detectors is that the Hybrid Photon Detectors need to be replaced as the readout chip is inside the detector vacuum. The baseline for replacement are Multianode Photomultiplier tubes (MaPMT) and new readout electronics. The MaPMTs will be located in the fringe field of the LHCb dipole magnet with residual fields up to 25 G. Therefore, their behaviour in magnetic fields is critical. Here we report about studies of the Hamamatsu models R11265 and H12700 in a magnetic field in an effort to qualify them for use in the LHCb RICH upgrade. Comparisons to the known model R7600 are also made. Measurements of the collection efficiency and gain were performed for all three space directions as a function of the magnetic field strength. In addition to measurements with ba...

  4. Properties and microstructure of the Ru-coated carbon nano tube counter electrode for dye-sensitized solar cells.

    Science.gov (United States)

    Han, Jeungjo; Yu, Byungkwan; Noh, Yunyoung; Suh, Young Joon; Kim, Moon J; Yoo, Kicheon; Ko, Min Jae; Song, Ohsung

    2014-08-01

    In this study, we investigated the performance of dye-sensitized solar cells (DSSCs) with the ruthenium (Ru) coated multi-walled carbon nanotube (MWCNT) on the counter electrode (CE). High purity MWCNT (0.01~0.06 g) was sprayed on glass/fluorine-doped tin oxide (FTO). Then 30 nm-thick Ru thin films were coated on a MWCNT template at low temperature by atomic layer deposition (ALD) using RuDi and O2 as precursor to prepare Ru-CNT CE and the 0.45 cm2 DSSC device of glass/FTO/TiO2/Dye (N719)/electrolyte (C6DMII, GSCN)/Ru-CNT CE was fabricated. The surface morphology of CEs and the energy conversion efficiency of the DSSC device were characterized by scanning electron microscope (SEM), high-resolution transmission electron microscope (HRTEM), and photocurrent-voltage (I-V) measurement. We confirmed that effective surface of the CE increased linearly as the amount of MWCNT spray increased and the crystallized Ru was deposited very conformally around the MWCNT nano template. Moreover, the efficiency of the DSSC increased up to 3.3% as the amount of MWCNT increased.

  5. Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Ciarrocchi, Esther; Belcari, Nicola; Guerra, Alberto Del [Department of Physics, University of Pisa, Pisa (Italy); INFN, section of Pisa, Pisa (Italy); Cherry, Simon R. [Department of Biomedical Engineering, University of California, Davis, CA (United States); Lehnert, Adrienne; Hunter, William C. J.; McDougald, Wendy; Miyaoka, Robert S.; Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, WA (United States)

    2015-11-16

    A feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silicon photomultipliers (SiPMs) are photon counting devices with a fast impulse response and can potentially be used to quantify β-emitting radiotracer distributions by CLI. In this study, a Philips digital photon counting (PDPC) silicon photomultiplier detector was evaluated for measuring Cherenkov luminescence. The PDPC detector is a matrix of avalanche photodiodes, which were read one at a time in a dark count map (DCM) measurement mode (much like a CCD). This reduces the device active area but allows the information from a single avalanche photodiode to be preserved, which is not possible with analog SiPMs. An algorithm to reject the noisiest photodiodes and to correct the measured count rate for the dark current was developed. The results show that, in DCM mode and at (10–13) °C, the PDPC has a dynamic response to different levels of Cherenkov luminescence emitted by a β source and transmitted through an opaque medium. This suggests the potential for this approach to provide quantitative activity measurements. Interestingly, the potential use of the PDPC in DCM mode for direct imaging of Cherenkov luminescence, as a opposed to a scalar measurement device, was also apparent. We showed that a PDPC tile in DCM mode is able to detect and image a β source through its Cherenkov radiation emission. The detector’s dynamic response to different levels of radiation suggests its potential quantitative capabilities, and the DCM mode allows imaging with a better spatial resolution than the conventional event-triggered mode. Finally, the same acquisition procedure and data processing could

  6. Sub-aquatic response of a scintillator, fibre optic and silicon photomultiplier based radiation sensor

    International Nuclear Information System (INIS)

    Jackson, Sarah-F.; Monk, Stephen D.; Lennox, Kathryn; Stanley, Steven-J.

    2013-06-01

    We describe here, the sub-aquatic response of the RadLine R detector (a small, novel, remotely operated radiation detection instrument) when irradiated with gamma doses between 6 and 400 Svhr -1 . The National Nuclear Laboratory's (NNL, UK) RadLine R consists of an inorganic scintillating crystal coupled to a fibre optic cable which transports scintillation photons to a detector at the other end. A CCD camera is normally used for photon collection, however in this paper we trial a newer technology; the silicon photomultiplier (SiPM), namely SensL's MiniSL. SiPMs have performance characteristics similar to photomultiplier tubes (PMT), whilst benefiting from the practical advantages of solid-state technology which include; low operating voltage, robustness, compactness, insensitivity to magnetic fields and over-exposure to light. The MiniSL was chosen as its peak photon wavelength is well matched to the output from the scintillation crystal, as well as its fast recovery time (within the nano-second range). We use a clinical radiotherapy linear accelerator (linac) machine which produces x-rays by accelerating elections onto a target which then emits x-rays by Bremsstrahlung. The linac is rated at 6 MeV in energy, with a peak of approximately 2 MeV. The machine is capable of generating a highly precise dose at known distances between treatment head and scintillation crystal. Analysing the data gathered we were also able consider how the RadLine R might perform in larger aquatic environments for example First Generation Magnox Storage Ponds (FGMSP). Built in the 1950's they were originally intended to hold spent nuclear fuel for reprocessing, however now parts of the spent fuel have corroded; some of which are buried under a layer of sediment. Removal is not a trivial task due to elevated radiation levels, and the complexity of the environment. RadLine R has the potential to be of significant use for this and in other similar situations. (authors)

  7. Study of silicon photomultipliers fast amplifier and thermoregulation

    International Nuclear Information System (INIS)

    D'antone, I.; Fabbri, L.; Foschi, E.; Guandalini, C.; Laurenti, G.; Lax, I.; Levi, G.; Quadrani, L.; Sbarra, Ca.; Sbarra, Cr.; Villa, M.; Zoccoli, A.; Zuffa, M.

    2011-01-01

    The silicon photomultipliers (SiPM) are adopted in various physical applications, from medical physics to astrophysics, for their advantages in terms of cost and weight with respect to traditional photo detectors. Their low bias voltage supply (about 30 V), hardiness and resistance to magnetic field are ideal characteristics for space application. In the frame of INFN-Irst collaboration, some of them have been developed and produced at FBK (Trento-Italy), and have been characterized in the INFN laboratories of Bologna (DaSiPM2 collaboration). The SiPM can be used in conjunction with fibres and counters in high energy physics experiments. To exploit the SiPM time resolution, a fast amplifier has been studied. The SiPM gain depends critically on temperature and a thermal stabilization is also necessary. The use of a thermoelectric cooler module based on a Peltier cell has been investigated, and the results are shown.

  8. Silicon Photomultipliers in High Energy and Space Applications

    CERN Document Server

    Berra, Alessandro; Vallazza, Erik

    In recent years Silicon Photomultipliers (SiPMs) have been proposed as a new type of readout system for scintillating detectors in many experiments. SiPMs consist of a matrix of parallel-connected silicon micro-pixels, which are independent photon counters working in limited Geiger mode with very high gain. The goal of this thesis work is to describe the use of SiPMs as a readout system for plastic scintillators, both for tracking and calorimetry purposes. Different prototypes of scintillating bar tracker and shashlik calorimeters have been tested at CERN on the PS and SPS extracted beamlines. All the tests have been performed in the framework of the FACTOR (Fiber Apparatus for Calorimetry and Tracking with Optoelectronic Read-out) collaboration, a three year R&D project started in 2007 and funded by the Italian Institute of Nuclear Physics (INFN).

  9. A study of timing properties of Silicon Photomultipliers

    Science.gov (United States)

    Avella, Paola; De Santo, Antonella; Lohstroh, Annika; Sajjad, Muhammad T.; Sellin, Paul J.

    2012-12-01

    Silicon Photomultipliers (SiPMs) are solid-state pixelated photodetectors. Lately these sensors have been investigated for Time of Flight Positron Emission Tomography (ToF-PET) applications, where very good coincidence time resolution of the order of hundreds of picoseconds imply spatial resolution of the order of cm in the image reconstruction. The very fast rise time typical of the avalanche discharge improves the time resolution, but can be limited by the readout electronics and the technology used to construct the device. In this work the parameters of the equivalent circuit of the device that directly affect the pulse shape, namely the quenching resistance and capacitance and the diode and parasitic capacitances, were calculated. The mean rise time obtained with different preamplifiers was also measured.

  10. Silicon photomultiplier arrays for the LHCb scintillating fibre tracker

    CERN Multimedia

    Girard, Olivier Goran; Kuonen, Axel Kevin; Stramaglia, Maria Elena

    2017-01-01

    For the LHCb detector upgrade in 2019, a large scale scintillating fibre tracker read out with silicon photomultipliers is under construction. The harsh radiation environment (neutron and ionising radiation), the 40MHz read-out rate of the trigger less system and the large detector surface of 320m2 impose many challenges. We present the results from lab tests with 1MeV electrons and from the SPS test facility at CERN for the mulitchannel SiPM array that combines peak photo-detection efficiency of 48% and extremely low correlated noise. The measurements were performed with detectors irradiated with neutrons up to a fluence of 12*1011 neq/cm2 and single photon detection was maintained. First results of the characterization of the pre-series of 500 detectors delivered by Hamamatsu and irradiation studies on a large sample will be included.

  11. Analysis of transit time spread on FBK silicon photomultipliers

    International Nuclear Information System (INIS)

    Acerbi, F.; Gola, A.; Ferri, A.; Zorzi, N.; Paternoster, G.; Piemonte, C.

    2015-01-01

    In this paper we studied one of the aspects potentially limiting the single-photon time-resolution (SPTR) of the silicon photomultiplier (SiPM): the transit time spread (TTS). We illuminated the SiPM in different positions with a fast-pulsed laser collimated to a circular spot of 0.2 mm-diameter and acquired bi-dimensional maps of the avalanche-signal arrival time of RGB and RGB-HD SiPMs, produced at FBK. We studied the effect of both the number of bonding wires connecting the device to the package and the layout of the top-metal connection (on the device). We found that the TTS does not simply depend on the trace length between the cell and the bonding pad and it could vary in the range between tens of picoseconds (with 3 bonding connections) to more than one hundred of picoseconds (with one connection)

  12. Characterization of silicon photomultipliers and validation of the electrical model

    Science.gov (United States)

    Peng, Peng; Qiang, Yi; Ross, Steve; Burr, Kent

    2018-04-01

    This paper introduces a systematic way to measure most features of the silicon photomultipliers (SiPM). We implement an efficient two-laser procedure to measure the recovery time. Avalanche probability was found to play an important role in explaining the right behavior of the SiPM recovery process. Also, we demonstrate how equivalent circuit parameters measured by optical tests can be used in SPICE modeling to predict details of the time constants relevant to the pulse shape. The SiPM properties measured include breakdown voltage, gain, diode capacitor, quench resistor, quench capacitor, dark count rate, photodetection efficiency, cross-talk and after-pulsing probability, and recovery time. We apply these techniques on the SiPMs from two companies: Hamamatsu and SensL.

  13. Study of silicon photomultipliers fast amplifier and thermoregulation

    Energy Technology Data Exchange (ETDEWEB)

    D' antone, I. [INFN of Bologna, Viale B.Pichat 4/2, 40127 Bologna (Italy); Fabbri, L.; Foschi, E. [Department of Physics and INFN, Viale B.Pichat 4/2, 40127 Bologna (Italy); Guandalini, C.; Laurenti, G.; Lax, I. [INFN of Bologna, Viale B.Pichat 4/2, 40127 Bologna (Italy); Levi, G.; Quadrani, L.; Sbarra, Ca. [Department of Physics and INFN, Viale B.Pichat 4/2, 40127 Bologna (Italy); Sbarra, Cr., E-mail: cristina.sbarra@bo.infn.i [Department of Physics and INFN, Viale B.Pichat 4/2, 40127 Bologna (Italy); Villa, M.; Zoccoli, A. [Department of Physics and INFN, Viale B.Pichat 4/2, 40127 Bologna (Italy); Zuffa, M. [INFN of Bologna, Viale B.Pichat 4/2, 40127 Bologna (Italy)

    2011-02-21

    The silicon photomultipliers (SiPM) are adopted in various physical applications, from medical physics to astrophysics, for their advantages in terms of cost and weight with respect to traditional photo detectors. Their low bias voltage supply (about 30 V), hardiness and resistance to magnetic field are ideal characteristics for space application. In the frame of INFN-Irst collaboration, some of them have been developed and produced at FBK (Trento-Italy), and have been characterized in the INFN laboratories of Bologna (DaSiPM2 collaboration). The SiPM can be used in conjunction with fibres and counters in high energy physics experiments. To exploit the SiPM time resolution, a fast amplifier has been studied. The SiPM gain depends critically on temperature and a thermal stabilization is also necessary. The use of a thermoelectric cooler module based on a Peltier cell has been investigated, and the results are shown.

  14. Precise method for determining avalanche breakdown voltage of silicon photomultipliers

    Science.gov (United States)

    Chirikov-Zorin, I.

    2017-07-01

    A physically motivated method is proposed for determining the avalanche breakdown voltage of silicon photomultipliers (SiPM). The method is based on measuring the dependence of the relative photon detection efficiency (PDErel) on the bias voltage when one type of carriers (electron or hole) is injected into the avalanche multiplication zone of the p-n junction. The injection of electrons or holes from the base region of the SiPM semiconductor structure is performed using short-wave or long-wave light. At a low overvoltage (1-2 V) the detection efficiency is linearly dependent on the bias voltage; therefore, extrapolation to zero PDErel value determines the SiPM avalanche breakdown voltage with an accuracy within a few millivolts.

  15. Fast light pulse measurements and temporal fluctuations in photomultipliers

    International Nuclear Information System (INIS)

    Miehe, J.A.; Sipp, B.

    1975-01-01

    This paper reviews the results on time fluctuations in high gain first dynode photomultipliers used in single photon timing experiments; the theoretical analysis of the measurement of the shape of light pulses is recalled and the previously obtained results concerning time dispersion in the photocathode, first dynode space are discussed. In addition, the influence of the variations of the electron transit time in the multiplier on the time resolution curves of the detector is examined: the curves obtained by leading-edge triggering of the anodic pulse show a strong dependence on the threshold level of the discriminator. A single-photoelectron timing resolution of 270ps is measured using a low leading edge discrimination [fr

  16. IceCube Sensitivity for Low-Energy Neutrinos from Nearby Supernovae

    Science.gov (United States)

    Stamatikos, M.; Abbasi, R.; Berghaus, P.; Chirkin, D.; Desiati, P.; Diaz-Velez, J.; Dumm, J. P.; Eisch, J.; Feintzeig, J.; Hanson, K.; hide

    2012-01-01

    This paper describes the response of the IceCube neutrino telescope located at the geographic South Pole to outbursts of MeV neutrinos from the core collapse of nearby massive stars. IceCube was completed in December 2010 forming a lattice of 5160 photomultiplier tubes that monitor a volume of approx. 1 cu km in the deep Antarctic ice for particle induced photons. The telescope was designed to detect neutrinos with energies greater than 100 GeV. Owing to subfreezing ice temperatures, the photomultiplier dark noise rates are particularly low. Hence IceCube can also detect large numbers of MeV neutrinos by observing a collective rise in all photomultiplier rates on top of the dark noise. With 2 ms timing resolution, IceCube can detect subtle features in the temporal development of the supernova neutrino burst. For a supernova at the galactic center, its sensitivity matches that of a background-free megaton-scale supernova search experiment. The sensitivity decreases to 20 standard deviations at the galactic edge (30 kpc) and 6 standard deviations at the Large Magellanic Cloud (50 kpc). IceCube is sending triggers from potential supernovae to the Supernova Early Warning System. The sensitivity to neutrino properties such as the neutrino hierarchy is discussed, as well as the possibility to detect the neutronization burst, a short outbreak's released by electron capture on protons soon after collapse. Tantalizing signatures, such as the formation of a quark star or a black hole as well as the characteristics of shock waves, are investigated to illustrate IceCube's capability for supernova detection.

  17. Procedures and results of the measurements on large area photomultipliers for the NEMO project

    Science.gov (United States)

    Aiello, S.; Leonora, E.; Aloisio, A.; Ameli, F.; Amore, I.; Anghinolfi, M.; Anzalone, A.; Barbarino, G.; Barbarito, E.; Battaglieri, M.; Bazzotti, M.; Bellotti, R.; Bersani, A.; Beverini, N.; Biagi, S.; Bonori, M.; Bouhdaef, B.; Cacopardo, G.; Calı, C.; Capone, A.; Caponetto, L.; Carminati, G.; Cassano, B.; Ceres, A.; Chiarusi, T.; Circella, M.; Cocimano, R.; Coniglione, R.; Cordelli, M.; Costa, M.; D'Amico, A.; DeBonis, G.; DeRosa, G.; DeRuvo, G.; DeVita, R.; Distefano, C.; Flaminio, V.; Fratini, K.; Gabrielli, A.; Galeotti, S.; Gandolfi, E.; Giacomelli, G.; Giorgi, F.; Giovanetti, G.; Grimaldi, A.; Grmek, A.; Habel, R.; Imbesi, M.; Lonardo, A.; LoPresti, D.; Lucarelli, F.; Margiotta, A.; Marinelli, A.; Martini, A.; Masullo, R.; Maugeri, F.; Migneco, E.; Minutoli, S.; Mongelli, M.; Morganti, M.; Musico, P.; Musumeci, M.; Orlando, A.; Osipenko, M.; Papaleo, R.; Pappalardo, V.; Piattelli, P.; Piombo, D.; Raffaelli, F.; Raia, G.; Randazzo, N.; Reito, S.; Ricco, G.; Riccobene, G.; Ripani, M.; Rovelli, A.; Ruppi, M.; Russo, G. V.; Russo, S.; Sapienza, P.; Sedita, M.; Shirokov, E.; Simeone, F.; Sciliberto, D.; Sipala, V.; Sollima, C.; Spurio, M.; Stefani, F.; Taiuti, M.; Terreni, G.; Trasatti, L.; Urso, S.; Vecchi, M.; Vicini, P.; Wischnewski, R.

    2010-03-01

    The selection of the photomultiplier plays a crucial role in the R&D activity related to a large-scale underwater neutrino telescope. This paper illustrates the main procedures and facilities used to characterize the performances of 72 large area photomultipliers, Hamamatsu model R7081 sel. The voltage to achieve a gain of 5×10 7, dark count rate and single photoelectron time and charge properties of the overall response were measured with a properly attenuated 410 nm pulsed laser. A dedicated study of the spurious pulses was also performed. The results prove that the photomultipliers comply with the general requirements imposed by the project.

  18. Cape Point GAW Station Rn-222 detector: factors affecting sensitivity and accuracy

    CSIR Research Space (South Africa)

    Brunke, EG

    2002-05-01

    Full Text Available . Furthermore, the new photomultiplier tube used (Elec- tron Tubes Model 9638B) differed somewhat from the one (Model 9531B) for which the head was originally designed. This note discusses these modifications, and provides a basis for evaluating future...

  19. Study of the radiation damage of silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Nitschke, Michael; Chmill, Valery; Garutti, Erika; Klanner, Robert; Schwandt, Joern [Institute for Experimental Physics, Hamburg University, Luruper Chaussee 149, D-22761 Hamburg (Germany)

    2016-07-01

    Radiation damage significantly changes the performance of silicon photomultipliers (SiPM). In this work, we first have characterized KETEK SiPMs with a pixel size of 15 x 15 μm{sup 2} using I-V (current-voltage), C/G-V/f (capacitance/impedance-voltage/frequency) and Q-V (charge-voltage) measurements with and without illumination with blue light of 470 nm from an LED. The SiPM parameters determined are DCR (dark count rate), relative PDE (photon detection efficiency), G (Gain), XT (cross-talk), Geiger breakdown characteristics, C{sub pix} (pixel capacitance) and R{sub q} (quenching resistance). Following this first characterization, the SiPMs were irradiated using reactor neutrons with fluences of 10{sup 9}, 10{sup 10}, 10{sup 11}, 5 . 10{sup 11}, and 10{sup 12} n/cm{sup 2}. Afterwards, the same measurements were repeated, and the dependence of the SiPM parameters on neutron fluence was determined. The results are used to optimize the radiation tolerance of SiPMs.

  20. Silicon photomultipliers. Properties and applications in a highly granular calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Feege, Nils

    2008-12-15

    Silicon Photomultipliers (SiPMs) are novel semiconductor-based photodetectors operated in Geiger mode. Their response is not linear, and both their gain and their photon detection efficiency depend on the applied bias voltage and on temperature. The CALICE collaboration investigates several technology options for highly granular calorimeters for the future ILC. The prototype of a scintillator-steel sampling calorimeter with analogue readout for hadrons constructed at DESY and successfully operated in testbeam experiments at DESY, CERN and FNAL by this collaboration is the first large scale application for 7608 SiPMs developed by MEPhI. This thesis deals with properties of the SiPMs used in the calorimeter prototype. The effective numer of pixels of the SiPMs, which influences their saturation behaviour, is extracted from in situ measurements and compared to results obtained for the bare SiPMs. In addition, the effects of temperature and voltage changes on the parameters necessary for the calibration of the SiPMs and the detector are determined. Methods which allow for correcting or compensating these effects are evaluated. An approach to improve the absolute calibration of the temperature sensors in the prototype is described and temperature profiles are studied. Finally, a procedure to adjust the light yield of the cells of the prototype is presented. The results of the application of this procedure during the commissioning of the detector at FNAL are discussed. (orig.)

  1. SENTIRAD—An innovative personal radiation detector based on a scintillation detector and a silicon photomultiplier

    Science.gov (United States)

    Osovizky, A.; Ginzburg, D.; Manor, A.; Seif, R.; Ghelman, M.; Cohen-Zada, I.; Ellenbogen, M.; Bronfenmakher, V.; Pushkarsky, V.; Gonen, E.; Mazor, T.; Cohen, Y.

    2011-10-01

    The alarming personal radiation detector (PRD) is a device intended for Homeland Security (HLS) applications. This portable device is designed to be worn or carried by security personnel to detect photon-emitting radioactive materials for the purpose of crime prevention. PRD is required to meet the scope of specifications defined by various HLS standards for radiation detection. It is mandatory that the device be sensitive and simultaneously small, pocket-sized, of robust mechanical design and carriable on the user's body. To serve these specialized purposes and requirements, we developed the SENTIRAD, a new radiation detector designed to meet the performance criteria established for counterterrorist applications. SENTIRAD is the first commercially available PRD based on a CsI(Tl) scintillation crystal that is optically coupled with a silicon photomultiplier (SiPM) serving as a light sensor. The rapidly developing technology of SiPM, a multipixel semiconductor photodiode that operates in Geiger mode, has been thoroughly investigated in previous studies. This paper presents the design considerations, constraints and radiological performance relating to the SENTIRAD radiation sensor.

  2. A robust and semi-automatic procedure for Silicon Photomultipliers characterisation

    Science.gov (United States)

    Arosio, V.; Beretta, M.; Caccia, M.; Santoro, R.

    2017-03-01

    Silicon Photomultipliers are state-of-the-art solid state sensors of light with single photon sensitivity, unprecedented photon number resolving capability and high photon detection efficiency. SiPM are cost effective, compact, magnetic field insensitive and with an extreme flexibility in the design to cope with different applications in fundamental and applied science and industry. As a rapidly evolving technology, new generation of sensors are being continuously proposed by different producers, requiring the development of reliable and efficient SiPM characterisation methods to perform a quick assessment and comparison. The procedure presented here is based on post-processing of digitised SiPM waveforms recording the response of the sensor to an ultra-fast light pulse. For every pulse, the signal is synchronously sampled, digitised and recorded on the timescale of a few microseconds with the objective of extracting from a single set of waveforms a full picture of the sensor characteristics in terms of Gain, Breakdown Voltage, Dark Count Rate , Optical Cross-Talk and After Pulse probability. The need of a unique and consistent data-set guarantees a fast and robust characterisation, stable against environmental condition changes, notably temperature.

  3. Possible application of silicon photomultiplier technology to detect the presence of spirit and intention: three proof-of-concept experiments.

    Science.gov (United States)

    Schwartz, Gary E

    2010-01-01

    Research investigating the survival of consciousness hypothesis has been hampered by the lack of an independent measure of the purported presence of spirit (POS). Although numerous anecdotes involving electronic devices (including tape recorders, answering machines, and computers) claim that POS can be detected with sensitive electromagnetic sensors, little systematic laboratory research has investigated this possibility. The purpose of this exploratory laboratory research was to test the feasibility of using a state-of-the-art silicon photomultiplier system to detect low photon levels potentially associated with POS. A PCDMini photon counting device manufactured by sensL provided a sensitive measure of sums of photons over time. Three proof-of-concept experiments were conducted. Each included multiple five-minute trials of "invited spirit" conditions as well as baseline controls. One experiment included a set of 10 noninvited control trials as well as controls for experimenter intention per se. Data were collected as part of a university laboratory devoted to researching advances in consciousness and health. The participants were purported spirits presumably motivated to participate in the research. The primary intervention was the experimenter's intention for purported spirits to enter the light-tight chamber on specified trials. In a light-tight chamber, the PCDMini device software counted and displayed individual sums of typically 13 to 25 photon detections per approximately 90-milliseconds time periods (in complete darkness, most time periods contained zero photons detected); the number of photon sums could be counted precisely in five-minute periods. The average number of photon sums was found to be significantly higher in purported POS trials compared with noninvited trials. Matched control trials as well as explicit experimenter intention trials showed no effects. Silicon photomultiplier devices may be sufficiently sensitive to investigate the POS and

  4. Silicon photomultiplier modules for MRI-compatible PET

    Science.gov (United States)

    Sul, Woo-Suk; Kim, Hyoungtaek; Cho, Gyuseong

    2015-04-01

    Silicon photomultiplier (SiPM) modules were developed for use in positron emission tomography-magnetic resonance imaging (PET-MRI), which is a hybrid medical imaging technology. A PET-MRI is very efficient in the early diagnosis of representative senile diseases, including cancer, Alzheimer's disease, and Parkinson's disease. SiPMs comprise the core image sensor for MR-compatible PET applications since they have a low operational voltage, high gain, good timing resolution, ruggedness, insensitivity to magnetic fields, compactness, and low cost. In PET systems, SiPM microcells can be optimized by making a trade-off between photon detection efficiency (PDE) and dynamic range. The SiPM modules used in this study were fabricated at the National NanoFab Center (NNFC) of South Korea by using a customized CMOS processes. The SiPM modules were evaluated by first packaging them with a cost-effective PCB package instead of with a conventional ceramic package. Measurements on 1,400 SiPMs indicated a uniform breakdown voltage of 20.54 V with a standard deviation of 0.07 V. Moreover, the SiPM modules present a high and uniform energy resolution of 13.6% with a standard deviation of 0.5% at 511 keV with 3 × 3 × 20 mm3 cerium-doped lutetium-yttrium oxyorthosilicate (Lu2(1-x)Y2xSiO5:Ce, LYSO) crystal coupling. These results indicated that the proposed devices offer adequate performance to form the foundation of an image sensor technology for MRI-compatible PET.

  5. On the sensitivity of the HAWC observatory to gamma-ray bursts

    Science.gov (United States)

    Abeysekara, A. U.; Aguilar, J. A.; Aguilar, S.; Alfaro, R.; Almaraz, E.; Álvarez, C.; Álvarez-Romero, J. de D.; Álvarez, M.; Arceo, R.; Arteaga-Velázquez, J. C.; Badillo, C.; Barber, A.; Baughman, B. M.; Bautista-Elivar, N.; Belmont, E.; Benítez, E.; BenZvi, S. Y.; Berley, D.; Bernal, A.; Bonamente, E.; Braun, J.; Caballero-Lopez, R.; Cabrera, I.; Carramiñana, A.; Carrasco, L.; Castillo, M.; Chambers, L.; Conde, R.; Condreay, P.; Cotti, U.; Cotzomi, J.; D'Olivo, J. C.; de la Fuente, E.; De León, C.; Delay, S.; Delepine, D.; DeYoung, T.; Diaz, L.; Diaz-Cruz, L.; Dingus, B. L.; Duvernois, M. A.; Edmunds, D.; Ellsworth, R. W.; Fick, B.; Fiorino, D. W.; Flandes, A.; Fraija, N. I.; Galindo, A.; García-Luna, J. L.; García-Torales, G.; Garfias, F.; González, L. X.; González, M. M.; Goodman, J. A.; Grabski, V.; Gussert, M.; Guzmán-Ceron, C.; Hampel-Arias, Z.; Harris, T.; Hays, E.; Hernandez-Cervantes, L.; Hüntemeyer, P. H.; Imran, A.; Iriarte, A.; Jimenez, J. J.; Karn, P.; Kelley-Hoskins, N.; Kieda, D.; Langarica, R.; Lara, A.; Lauer, R.; Lee, W. H.; Linares, E. C.; Linnemann, J. T.; Longo, M.; Luna-García, R.; Martínez, H.; Martínez, J.; Martínez, L. A.; Martínez, O.; Martínez-Castro, J.; Martos, M.; Matthews, J.; McEnery, J. E.; Medina-Tanco, G.; Mendoza-Torres, J. E.; Miranda-Romagnoli, P. A.; Montaruli, T.; Moreno, E.; Mostafa, M.; Napsuciale, M.; Nava, J.; Nellen, L.; Newbold, M.; Noriega-Papaqui, R.; Oceguera-Becerra, T.; Olmos Tapia, A.; Orozco, V.; Pérez, V.; Pérez-Pérez, E. G.; Perkins, J. S.; Pretz, J.; Ramirez, C.; Ramírez, I.; Rebello, D.; Rentería, A.; Reyes, J.; Rosa-González, D.; Rosado, A.; Ryan, J. M.; Sacahui, J. R.; Salazar, H.; Salesa, F.; Sandoval, A.; Santos, E.; Schneider, M.; Shoup, A.; Silich, S.; Sinnis, G.; Smith, A. J.; Sparks, K.; Springer, W.; Suárez, F.; Suarez, N.; Taboada, I.; Tellez, A. F.; Tenorio-Tagle, G.; Tepe, A.; Toale, P. A.; Tollefson, K.; Torres, I.; Ukwatta, T. N.; Valdes-Galicia, J.; Vanegas, P.; Vasileiou, V.; Vázquez, O.; Vázquez, X.; Villaseñor, L.; Wall, W.; Walters, J. S.; Warner, D.; Westerhoff, S.; Wisher, I. G.; Wood, J.; Yodh, G. B.; Zaborov, D.; Zepeda, A.

    2012-05-01

    We present the sensitivity of HAWC to gamma ray bursts (GRBs). HAWC is a very high-energy gamma-ray observatory currently under construction in Mexico at an altitude of 4100 m. It will observe atmospheric air showers via the water Cherenkov method. HAWC will consist of 300 large water tanks instrumented with 4 photomultipliers each. HAWC has two data acquisition (DAQ) systems. The main DAQ system reads out coincident signals in the tanks and reconstructs the direction and energy of individual atmospheric showers. The scaler DAQ counts the hits in each photomultiplier tube (PMT) in the detector and searches for a statistical excess over the noise of all PMTs. We show that HAWC has a realistic opportunity to observe the high-energy power law components of GRBs that extend at least up to 30 GeV, as it has been observed by Fermi LAT. The two DAQ systems have an energy threshold that is low enough to observe events similar to GRB 090510 and GRB 090902b with the characteristics observed by Fermi LAT. HAWC will provide information about the high-energy spectra of GRBs which in turn could help to understanding about e-pair attenuation in GRB jets, extragalactic background light absorption, as well as establishing the highest energy to which GRBs accelerate particles.

  6. Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Guen Bae; Kim, Kyeong Yun; Yoon, Hyun Suk; Son, Jeong-Whan [Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 110-799, South Korea and Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of); Lee, Min Sun [Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 110-799, South Korea and Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of); Im, Hyung-Jun [Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of); Lee, Jae Sung, E-mail: jaes@snu.ac.kr [Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of); Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of); Institute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of)

    2016-01-15

    Purpose: In this study, the authors present a silicon photomultiplier (SiPM)-based positron emission tomography (PET) insert dedicated to small animal imaging with high system performance and robustness to temperature change. Methods: The insert consists of 64 LYSO-SiPM detector blocks arranged in 4 rings of 16 detector blocks to yield a ring diameter of 64 mm and axial field of view of 55 mm. Each detector block consists of a 9 × 9 array of LYSO crystals (1.2 × 1.2 × 10 mm{sup 3}) and a monolithic 4 × 4 SiPM array. The temperature of each monolithic SiPM is monitored, and the proper bias voltage is applied according to the temperature reading in real time to maintain uniform performance. The performance of this PET insert was characterized using National Electrical Manufacturers Association NU 4-2008 standards, and its feasibility was evaluated through in vivo mouse imaging studies. Results: The PET insert had a peak sensitivity of 3.4% and volumetric spatial resolutions of 1.92 (filtered back projection) and 0.53 (ordered subset expectation maximization) mm{sup 3} at center. The peak noise equivalent count rate and scatter fraction were 42.4 kcps at 15.08 MBq and 16.5%, respectively. By applying the real-time bias voltage adjustment, an energy resolution of 14.2% ± 0.3% was maintained and the count rate varied ≤1.2%, despite severe temperature changes (10–30 °C). The mouse imaging studies demonstrate that this PET insert can produce high-quality images useful for imaging studies on the small animals. Conclusions: The developed MR-compatible PET insert is designed for insertion into a narrow-bore magnetic resonance imaging scanner, and it provides excellent imaging performance for PET/MR preclinical studies.

  7. Ear Tubes

    Science.gov (United States)

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  8. Multi-time-over-threshold technique for photomultiplier signal processing: Description and characterization of the SCOTT ASIC

    International Nuclear Information System (INIS)

    Ferry, S.; Guilloux, F.; Anvar, S.; Chateau, F.; Delagnes, E.; Gautard, V.; Louis, F.; Monmarthe, E.; Le Provost, H.; Russo, S.; Schuller, J.-P.; Stolarczyk, Th.; Vallage, B.; Zonca, E.

    2012-01-01

    KM3NeT aims to build a cubic-kilometer scale neutrino telescope in the Mediterranean Sea based on a 3D array of photomultiplier tubes. A dedicated ASIC, named SCOTT, has been developed for the readout electronics of the PMTs: it uses up to 16 adjustable thresholds to digitize the signals with the multi-time-over-threshold technique. Digital outputs of discriminators feed a circular sampling memory and a “first in first out” digital memory for derandomization. At the end of the data processing, the ASIC produces a digital waveform sampled at 800 MHz. A specific study was carried out to process PMT data and has showed that five specifically chosen thresholds are suited to reach the required timing precision. A dedicated method based on the duration of the signal over a given threshold allows an equivalent timing precision at any charge. A charge estimator using the information from the thresholds allows a charge determination within less than 20% up to 60 pe.

  9. Multi-time-over-threshold technique for photomultiplier signal processing: Description and characterization of the SCOTT ASIC

    Science.gov (United States)

    Ferry, S.; Guilloux, F.; Anvar, S.; Chateau, F.; Delagnes, E.; Gautard, V.; Louis, F.; Monmarthe, E.; Le Provost, H.; Russo, S.; Schuller, J.-P.; Stolarczyk, Th.; Vallage, B.; Zonca, E.; Representing the KM3NeT Consortium

    2012-12-01

    KM3NeT aims to build a cubic-kilometer scale neutrino telescope in the Mediterranean Sea based on a 3D array of photomultiplier tubes. A dedicated ASIC, named SCOTT, has been developed for the readout electronics of the PMTs: it uses up to 16 adjustable thresholds to digitize the signals with the multi-time-over-threshold technique. Digital outputs of discriminators feed a circular sampling memory and a “first in first out” digital memory for derandomization. At the end of the data processing, the ASIC produces a digital waveform sampled at 800 MHz. A specific study was carried out to process PMT data and has showed that five specifically chosen thresholds are suited to reach the required timing precision. A dedicated method based on the duration of the signal over a given threshold allows an equivalent timing precision at any charge. A charge estimator using the information from the thresholds allows a charge determination within less than 20% up to 60 pe.

  10. Photomultipliers gain monitoring at the one percent level with a blue light pulser

    International Nuclear Information System (INIS)

    Berger, J.; Bermond, M.; Besson, P.; Favier, J.; Pessard, H.; Poulet, M.

    1988-07-01

    We describe a method and an experimental layout allowing the monitoring of photomultipliers gain. We use artificial blue light (Spark-gap with filter: 436 ± 20 nm) and three reference detectors. Short term and long term measurements are presented. The results indicate a precision better than 0.5% for the short term and 1.4% for the long term determinations. This gain monitoring system has been developed for a new neutrino oscillation reactor experiment (600 photomultipliers) starting at the Bugey nuclear plant

  11. Study of the Light Emission Process from the Double Chooz Photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, E.; Cerrada, M.; Crespo, J. I.; Gil-Botella, I.; Jimenez, S.; Lopez, M.; Novella, P.; Palomares, C.; Santorelli, R.; Verdugo, A.

    2012-09-13

    In this document we present a study of the light emitted by the base of a Hamamatsu R7081MOD-ASSY photomultiplier (PMT) of the same type used in the Double Chooz experiment. Several characteristic features of the light signal have been found in terms of amplitude, length and pulse shape. Additional investigations on the properties of the epoxy used to cover the photomultiplier base have been carried out. A possible explanation of the light emission process is discussed at the end of the study. (Author) 1 ref.

  12. Characterization of 1600 Hamamatsu 16-anode photomultipliers for the MINOS Far detector

    International Nuclear Information System (INIS)

    Lang, K.; Day, J.; Eilerts, S.; Fuqua, S.; Guillen, A.; Kordosky, M.; Lang, M.; Liu, J.; Opaska, W.; Proga, M.; Vahle, P.; Winbow, A.; Drake, G.; Thomas, J.; Andreopoulos, C.; Saoulidou, N.; Stamoulis, P.; Tzanakos, G.; Zois, M.; Weber, A.; Michael, D.

    2005-01-01

    We are reporting results of the characterization of over 1600 multi-anode R5900-00-M16 photomultipliers manufactured by Hamamatsu Photonics K.K., and installed in the MINOS Far detector. We have conducted extensive tests of the uniformity of gain and collection efficiency of individual anodes, the cross-talk among all 16 channels, the dark noise, and the linearity of response. In our studies we used a blue light-emitting diode to illuminate phototubes through 1.2 mm diameter optical fibers. In this paper, we present summaries of the main characteristics of the tested photomultipliers

  13. Research on large area VUV-sensitive gaseous photomultipliers for cryogenic applications

    Science.gov (United States)

    Coimbra, Artur Emanuel Cardoso

    Desde cedo que a comunidade cientifica compreendeu que gases nobres em liquido sao excelentes meios de deteccao de radiacao, combinando a sua elevada densidade, elevado grau de homogeneidade e de elevado rendimento de cintilacao. Para alem destas caracteristicas inerentes, estes tem a potencialidade de fornecer ambos sinais de ionizacao - criando electroes livres - e cintilacao em resposta a interaccao com radiacao ionizante e, tendo em vista a sua aplicacao em experiencias de eventos raros relacionados com fisica de neutrinos ou materia-escura, a capacidade de autoblindagem garante a exclusao de eventos induzidos por radiacao de fundo. O facto de nao absorverem a sua propria luz, emergente dos eventos de cintilacao, permite a expansao deste tipo de detectores ate grandes volumes, sendo que as colaboracoes mais recentes propoem detectores com dezenas de toneladas de xenon em estado liquido. As experiencias actuais que usam gases nobres em estado liquido empregam xenon ou argon numa so fase (estado liquido) ou em dupla-fase (estado liquido + gasoso) e as suas aplicacoes abrangem desde as ja referidas experiencias de procura de eventos raros, passando por imagiologia medica tais como detectores de radiacao gama para PET ou câmaras Compton "3-gamma" em combinacao com PET, passando tambem por aplicacoes de seguranca como sistemas de inspeccao para deteccao de material fissil e, finalmente, em câmaras Compton para aplicacoes de astrofisica. Em ambas as configuracoes a leitura dos sinais de cintilacao e geralmente feita atraves de um grande numero de dispendiosos fotomultiplicadores de vacuo agrupados. A presente tese de doutoramento e dedicada aos fotomultiplicadores gasosos de grande area para aplicacoes criogenicas desenvolvidos no contexto do programa doutoral, tendo em vista a sua eventual aplicacao como um dispositivo complementar aos metodos existentes de deteccao de cintilacao, para aplicacao em futuras experiencias de grande escala. Esta pesquisa foi direccionada tendo em vista o desenvolvimento de eficientes fotomultiplicadores gasosos de grande area, potencialmente mais economicos por unidade de area, baseados em "Thick Gas-Electron Multipliers" (THGEMs). Combinando fotocatodos de alta eficiencia com multiplicadores gasosos de electroes capazes de atingir elevado ganho em carga obteve-se assim um dispositivo com elevada sensibilidade para a deteccao de fotoes unicos, com a possibilidade de discriminacao em posicao com resolucao espacial inferior a um milimetro e com resolucao temporal da ordem de poucos nano segundos. Contrariamente ao que sucede com a tecnologia de vacuo actualmente, com este dispositivo a localizacao em posicao de fotoes em grandes areas e feita num unico dispositivo integrando electronica habitualmente utilizada em experiencias de rastreamento de particulas. Neste trabalho o fotomultiplicador gasoso desenvolvido consiste numa cadeia de THGEMs combinados com um fotocatodo de iodeto de cesio (CsI) sensivel ao ultravioleta enquanto que os testes criogenicos foram realizados na Time Projection Chamber (TPC) de dupla fase de xenon liquido recentemente desenvolvida no Weizmann Institute of Science (WILiX). (Abstract shortened by ProQuest.).

  14. Neutron tubes

    Science.gov (United States)

    Leung, Ka-Ngo [Hercules, CA; Lou, Tak Pui [Berkeley, CA; Reijonen, Jani [Oakland, CA

    2008-03-11

    A neutron tube or generator is based on a RF driven plasma ion source having a quartz or other chamber surrounded by an external RF antenna. A deuterium or mixed deuterium/tritium (or even just a tritium) plasma is generated in the chamber and D or D/T (or T) ions are extracted from the plasma. A neutron generating target is positioned so that the ion beam is incident thereon and loads the target. Incident ions cause D-D or D-T (or T-T) reactions which generate neutrons. Various embodiments differ primarily in size of the chamber and position and shape of the neutron generating target. Some neutron generators are small enough for implantation in the body. The target may be at the end of a catheter-like drift tube. The target may have a tapered or conical surface to increase target surface area.

  15. A method to stabilise the performance of negatively fed KM3NeT photomultipliers

    NARCIS (Netherlands)

    Adrián-Martínez, S.; van Haren, H.; KM3NeT Collaboration

    2016-01-01

    The KM3NeT research infrastructure, currently under construction in the Mediterranean Sea, will host neutrino telescopes for the identification of neutrino sources in the Universe and for studies of the neutrino mass hierarchy. These telescopes will house hundreds of thousands of photomultiplier

  16. Silicon photomultiplier's gain stabilization by bias correction for compensation of the temperature fluctuations

    International Nuclear Information System (INIS)

    Dorosz, P.; Baszczyk, M.; Glab, S.; Kucewicz, W.; Mik, L.; Sapor, M.

    2013-01-01

    Gain of the silicon photomultiplier is strongly dependent on the value of bias voltage and temperature. This paper proposes a method for gain stabilization just by compensation of temperature fluctuations by bias correction. It has been confirmed that this approach gives good results and the gain can be kept very stable

  17. Electronics of the data acquisition system of the DANSS detector based on silicon photomultipliers

    Science.gov (United States)

    Svirida, D.

    2018-01-01

    The electronics of the data acquisition system based on silicon photomultipliers is briefly described. The elements and modules of the system were designed and constructed at ITEP especially for the DANSS detector. Examples of digitized signals obtained with the presented electronic modules and selected results on processing of the DANSS engineering data-taking run in spring 2016 are given.

  18. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  19. Digital position sensitive discrimination for 2-dimensional scintillation detectors

    International Nuclear Information System (INIS)

    Engels, R.; Reinartz, R.; Reinhart, P.

    1996-01-01

    The energy sensitivity of a two-dimensional scintillation gamma detector based on position sensitive photomultipliers has been minimized by a digital differential discrimination unit. Since the photomultiplier gain is position-dependent by 50%, a discrimination unit has been developed where digital upper and lower discrimination levels are set due to the position-dependent photomultiplier gain obtained from calibration measurements. Depending on the spatial resolution there can be up to 65.536 position-sensitive discriminator levels defining energy windows. By this method, narrow discriminator windows can be used for reducing the low and high energy quanta without effecting the sensitivity of the detector. The new discrimination method, its performance and test measurements with gamma rays will be described. Furthermore experimental results are presented

  20. High-speed digitization readout of silicon photomultipliers for time of flight positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ronzhin, A.; Los, S.; Martens, M.; Ramberg, E.; /Fermilab; Kim, H.; Chen, C.; Kao, C.; /Chicago U.; Niessen, K.; /SUNY, Buffalo; Zatserklyaniy, A.; /Puerto Rico U., Mayaguez; Mazzillo, M.; Carbone, B.; /SGS Thomson, Catania

    2011-02-01

    We report on work to develop a system with about 100 picoseconds (ps) time resolution for time of flight positron emission tomography [TOF-PET]. The chosen photo detectors for the study were Silicon Photomultipliers (SiPM's). This study was based on extensive experience in studying timing properties of SiPM's. The readout of these devices used the commercial high speed digitizer DRS4. We applied different algorithms to get the best time resolution of 155 ps Guassian (sigma) for a LYSO crystal coupled to a SiPM. We consider the work as a first step in building a prototype TOF-PET module. The field of positron-emission-tomography (PET) has been rapidly developing. But there are significant limitations in how well current PET scanners can reconstruct images, related to how fast data can be acquired, how much volume they can image, and the spatial and temporal resolution of the generated photons. Typical modern scanners now include multiple rings of detectors, which can image a large volume of the patient. In this type of scanner, one can treat each ring as a separate detector and require coincidences only within the ring, or treat the entire region viewed by the scanner as a single 3 dimensional volume. This 3d technique has significantly better sensitivity since more photon pair trajectories are accepted. However, the scattering of photons within the volume of the patient, and the effect of random coincidences limits the technique. The advent of sub-nanosecond timing resolution detectors means that there is potentially much better rejection of scattered photon events and random coincidence events in the 3D technique. In addition, if the timing is good enough, then the origin of photons pairs can be determined better, resulting in improved spatial resolution - so called 'Time-of-Flight' PET, or TOF-PET. Currently a lot of activity has occurred in applications of SiPMs for TOF-PET. This is due to the devices very good time resolution, low profile

  1. Studies of a Next-Generation Silicon-Photomultiplier-Based Time-of-Flight PET/CT System.

    Science.gov (United States)

    Hsu, David F C; Ilan, Ezgi; Peterson, William T; Uribe, Jorge; Lubberink, Mark; Levin, Craig S

    2017-09-01

    This article presents system performance studies for the Discovery MI PET/CT system, a new time-of-flight system based on silicon photomultipliers. System performance and clinical imaging were compared between this next-generation system and other commercially available PET/CT and PET/MR systems, as well as between different reconstruction algorithms. Methods: Spatial resolution, sensitivity, noise-equivalent counting rate, scatter fraction, counting rate accuracy, and image quality were characterized with the National Electrical Manufacturers Association NU-2 2012 standards. Energy resolution and coincidence time resolution were measured. Tests were conducted independently on two Discovery MI scanners installed at Stanford University and Uppsala University, and the results were averaged. Back-to-back patient scans were also performed between the Discovery MI, Discovery 690 PET/CT, and SIGNA PET/MR systems. Clinical images were reconstructed using both ordered-subset expectation maximization and Q.Clear (block-sequential regularized expectation maximization with point-spread function modeling) and were examined qualitatively. Results: The averaged full widths at half maximum (FWHMs) of the radial/tangential/axial spatial resolution reconstructed with filtered backprojection at 1, 10, and 20 cm from the system center were, respectively, 4.10/4.19/4.48 mm, 5.47/4.49/6.01 mm, and 7.53/4.90/6.10 mm. The averaged sensitivity was 13.7 cps/kBq at the center of the field of view. The averaged peak noise-equivalent counting rate was 193.4 kcps at 21.9 kBq/mL, with a scatter fraction of 40.6%. The averaged contrast recovery coefficients for the image-quality phantom were 53.7, 64.0, 73.1, 82.7, 86.8, and 90.7 for the 10-, 13-, 17-, 22-, 28-, and 37-mm-diameter spheres, respectively. The average photopeak energy resolution was 9.40% FWHM, and the average coincidence time resolution was 375.4 ps FWHM. Clinical image comparisons between the PET/CT systems demonstrated the high

  2. Balloon flight test of a Compton telescope based on scintillators with silicon photomultiplier readouts

    Science.gov (United States)

    Bloser, P. F.; Legere, J. S.; Bancroft, C. M.; Ryan, J. M.; McConnell, M. L.

    2016-03-01

    We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of high-energy astronomy and solar physics for new medium-energy gamma-ray ( 0.4-10 MeV) detectors capable of making sensitive observations of both line and continuum sources over a wide dynamic range. A fast scintillator-based Compton telescope with SiPM readouts is a promising solution to this instrumentation challenge, since the fast response of the scintillators permits both the rejection of background via time-of-flight (ToF) discrimination and the ability to operate at high count rates. The Solar Compton Telescope (SolCompT) prototype presented here was designed to demonstrate stable performance of this technology under balloon-flight conditions. The SolCompT instrument was a simple two-element Compton telescope, consisting of an approximately one-inch cylindrical stilbene crystal for a scattering detector and a one-inch cubic LaBr3:Ce crystal for a calorimeter detector. Both scintillator detectors were read out by 2×2 arrays of Hamamatsu S11828-3344 MPPC devices. Custom front-end electronics provided optimum signal rise time and linearity, and custom power supplies automatically adjusted the SiPM bias voltage to compensate for temperature-induced gain variations. A tagged calibration source, consisting of 240 nCi of 60Co embedded in plastic scintillator, was placed in the field of view and provided a known source of gamma rays to measure in flight. The SolCompT balloon payload was launched on 24 August 2014 from Fort Sumner, NM, and spent 3.75 h at a float altitude of 123,000 ft. The instrument performed well throughout the flight. After correcting for small ( 10%) residual gain variations, we measured an in-flight ToF resolution of 760 ps (FWHM). Advanced scintillators with SiPM readouts continue to show great promise for

  3. Balloon flight test of a Compton telescope based on scintillators with silicon photomultiplier readouts

    International Nuclear Information System (INIS)

    Bloser, P.F.; Legere, J.S.; Bancroft, C.M.; Ryan, J.M.; McConnell, M.L.

    2016-01-01

    We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of high-energy astronomy and solar physics for new medium-energy gamma-ray (~0.4–10 MeV) detectors capable of making sensitive observations of both line and continuum sources over a wide dynamic range. A fast scintillator-based Compton telescope with SiPM readouts is a promising solution to this instrumentation challenge, since the fast response of the scintillators permits both the rejection of background via time-of-flight (ToF) discrimination and the ability to operate at high count rates. The Solar Compton Telescope (SolCompT) prototype presented here was designed to demonstrate stable performance of this technology under balloon-flight conditions. The SolCompT instrument was a simple two-element Compton telescope, consisting of an approximately one-inch cylindrical stilbene crystal for a scattering detector and a one-inch cubic LaBr 3 :Ce crystal for a calorimeter detector. Both scintillator detectors were read out by 2×2 arrays of Hamamatsu S11828-3344 MPPC devices. Custom front-end electronics provided optimum signal rise time and linearity, and custom power supplies automatically adjusted the SiPM bias voltage to compensate for temperature-induced gain variations. A tagged calibration source, consisting of ~240 nCi of 60 Co embedded in plastic scintillator, was placed in the field of view and provided a known source of gamma rays to measure in flight. The SolCompT balloon payload was launched on 24 August 2014 from Fort Sumner, NM, and spent ~3.75 h at a float altitude of ~123,000 ft. The instrument performed well throughout the flight. After correcting for small (~10%) residual gain variations, we measured an in-flight ToF resolution of ~760 ps (FWHM). Advanced scintillators with SiPM readouts continue to show great

  4. Balloon flight test of a Compton telescope based on scintillators with silicon photomultiplier readouts

    Energy Technology Data Exchange (ETDEWEB)

    Bloser, P.F., E-mail: Peter.Bloser@unh.edu; Legere, J.S.; Bancroft, C.M.; Ryan, J.M.; McConnell, M.L.

    2016-03-11

    We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of high-energy astronomy and solar physics for new medium-energy gamma-ray (~0.4–10 MeV) detectors capable of making sensitive observations of both line and continuum sources over a wide dynamic range. A fast scintillator-based Compton telescope with SiPM readouts is a promising solution to this instrumentation challenge, since the fast response of the scintillators permits both the rejection of background via time-of-flight (ToF) discrimination and the ability to operate at high count rates. The Solar Compton Telescope (SolCompT) prototype presented here was designed to demonstrate stable performance of this technology under balloon-flight conditions. The SolCompT instrument was a simple two-element Compton telescope, consisting of an approximately one-inch cylindrical stilbene crystal for a scattering detector and a one-inch cubic LaBr{sub 3}:Ce crystal for a calorimeter detector. Both scintillator detectors were read out by 2×2 arrays of Hamamatsu S11828-3344 MPPC devices. Custom front-end electronics provided optimum signal rise time and linearity, and custom power supplies automatically adjusted the SiPM bias voltage to compensate for temperature-induced gain variations. A tagged calibration source, consisting of ~240 nCi of {sup 60}Co embedded in plastic scintillator, was placed in the field of view and provided a known source of gamma rays to measure in flight. The SolCompT balloon payload was launched on 24 August 2014 from Fort Sumner, NM, and spent ~3.75 h at a float altitude of ~123,000 ft. The instrument performed well throughout the flight. After correcting for small (~10%) residual gain variations, we measured an in-flight ToF resolution of ~760 ps (FWHM). Advanced scintillators with SiPM readouts continue to show

  5. Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET

    Science.gov (United States)

    Kwon, Sun Il; Gola, Alberto; Ferri, Alessandro; Piemonte, Claudio; Cherry, Simon R.

    2016-09-01

    Bismuth germanate (BGO) was a very attractive scintillator in early-generation positron emission tomography (PET) scanners. However, the major disadvantages of BGO are lower light yield and longer rise and decay time compared to currently popular scintillators such as LSO and LYSO. This results in poorer coincidence timing resolution and it has generally been assumed that BGO is not a suitable scintillator for time-of-flight (TOF) PET applications. However, when a 511 keV photon interacts in a scintillator, a number of Cerenkov photons are produced promptly by energetic electrons released by photoelectric or Compton interactions. If these prompt photons can be captured, they could provide a better timing trigger for PET. Since BGO has a high refractive index (increasing the Cerenkov light yield) and excellent optical transparency down to 320 nm (Cerenkov light yield is higher at shorter wavelengths), we hypothesized that the coincidence timing resolution of BGO can be significantly improved by efficient detection of the Cerenkov photons. However, since the number of Cerenkov photons is far less than the number of scintillation photons, and they are more abundant in the UV and blue part of the spectrum, photosensors need to have high UV/blue sensitivity, fast temporal response, and very low noise in order to trigger on the faint Cerenkov signal. In this respect, NUV-HD silicon photomultipliers (SiPMs) (FBK, Trento, Italy) are an excellent fit for our approach. In this study, coincidence events were measured using BGO crystals coupled with NUV-HD SiPMs. The existence and influence of Cerenkov photons on the timing measurements were studied using different configurations to exploit the directionality of the Cerenkov emissions. Coincidence resolving time values (FWHM) of ~270 ps from 2  ×  3  ×  2 mm3 BGO crystals and ~560 ps from 3  ×  3  ×  20 mm3 BGO crystals were obtained. To our knowledge, these are the best

  6. Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET

    Science.gov (United States)

    Kwon, Sun Il; Gola, Alberto; Ferri, Alessandro; Piemonte, Claudio; Cherry, Simon R.

    2016-01-01

    Bismuth germanate (BGO) was a very attractive scintillator in early-generation positron emission tomography (PET) scanners. However, the major disadvantages of BGO are lower light yield and longer rise and decay time compared to currently popular scintillators such as LSO and LYSO. This results in poorer coincidence timing resolution and it has generally been assumed that BGO is not a suitable scintillator for time-of-flight (TOF) PET applications. However, when a 511-keV photon interacts in a scintillator, a number of Cerenkov photons are produced promptly by energetic electrons released by photoelectric or Compton interactions. If these prompt photons can be captured, they could provide a better timing trigger for PET. Since BGO has a high refractive index (increasing the Cerenkov light yield) and excellent optical transparency down to 320 nm (Cerenkov light yield is higher at shorter wavelengths), we hypothesized that the coincidence timing resolution of BGO can be significantly improved by efficient detection of the Cerenkov photons. However, since the number of Cerenkov photons is far less than the number of scintillation photons, and they are more abundant in the UV and blue part of the spectrum, photosensors need to have high UV/blue sensitivity, fast temporal response, and very low noise in order to trigger on the faint Cerenkov signal. In this respect, NUV-HD silicon photomultipliers (SiPMs) (FBK, Trento, Italy) are an excellent fit for our approach. In this study, coincidence events were measured using BGO crystals coupled with NUV-HD SiPMs. The existence and influence of Cerenkov photons on the timing measurements were studied using different configurations to exploit the directionality of the Cerenkov emissions. Coincidence resolving time values (FWHM) of ~270 ps from 2 × 3 × 2 mm3 BGO crystals and ~560 ps from 3 × 3 × 20 mm3 BGO crystals were obtained. To our knowledge, these are the best coincidence resolving time values reported for BGO to date

  7. Study of the silicon photomultipliers and their applications in positron emission tomography

    International Nuclear Information System (INIS)

    Xu, Chen

    2014-05-01

    This thesis deals with silicon photomultipliers (SiPM) used in scintillation detectors and their applications in positron emission tomography (PET). The study of the SiPM is mainly focused on the application to the proposed EndoTOFPET-US detector, which is a multi-modality PET detector facilitating the development of new biomarkers for pancreas and prostate cancers. A Monte Carlo simulation tool is developed for the optimization of the detector's single channel design. In order to obtain a 200 ps system coincidence time resolution and maximize the detector sensitivity, the requirements for the crystal geometry, light yield and SiPM photon detection efficiency are specified based on the simulation study. In addition, the nonlinear response of the SiPM can be corrected by the simulation tool and the energy resolution of the detector is extracted. A series of measurements are established to characterize SiPMs in a fast and reliable way with high precision. The static characterization measures the value of different components in the derived electrical model of the SiPM, whereas the dynamic characterization extracts parameters that is crucial for the operation of the SiPM. Several SiPM samples are tested and their characteristics are compared. The developed setup and the precision of the measurement fulfill the requirements of the quality assurance test for the commissioning of the EndoTOFPET-US detector. The test foresees large quantities of SiPMs to be characterized. In addition, the developed measuring procedure has contributed to the study of X-ray induced surface damage of a SiPM from Hamamatsu. Characteristics of the device are measured before and after irradiating the SiPM with different X-ray doses, the results are compared and discussed. A comparative study of a digital and an analog SiPM in gamma spectroscopy with the inorganic scintillator is presented. The characteristics of a prototype digital SiPM that is developed for the EndoTOFPETUS detector is

  8. Tube-wave seismic imaging

    Science.gov (United States)

    Korneev, Valeri A [LaFayette, CA

    2009-05-05

    The detailed analysis of cross well seismic data for a gas reservoir in Texas revealed two newly detected seismic wave effects, recorded approximately 2000 feet above the reservoir. A tube-wave (150) is initiated in a source well (110) by a source (111), travels in the source well (110), is coupled to a geological feature (140), propagates (151) through the geological feature (140), is coupled back to a tube-wave (152) at a receiver well (120), and is and received by receiver(s) (121) in either the same (110) or a different receiving well (120). The tube-wave has been shown to be extremely sensitive to changes in reservoir characteristics. Tube-waves appear to couple most effectively to reservoirs where the well casing is perforated, allowing direct fluid contact from the interior of a well case to the reservoir.

  9. Recent advances and future perspectives of position sensitive PMT

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Mattioli, M.; Trotta, C.; Montani, L.; Iurlaro, G.; Trotta, G.; D'Addio, L.; Ridolfi, S.; De Vincentis, G.; Weinberg, I.N.

    2004-01-01

    In recent years there has been a growing interest in developing compact gamma cameras to improve gamma ray imaging for application in nuclear medicine as well as in astrophysics, radiation physics and high energy physics. The gamma cameras based on position sensitive photomultipliers could be the best chance to obtain a realistic and low cost compact gamma camera. Since 1985 the development of position sensitive photo multiplier tubes (PSPMT) has shown the highest rate in technological advancement achieving very compact size (25 x 25 x 20 mm 3 ) by a novel charge multiplication system. The PSPMT shows the same advantages of a standard gamma camera with the additional possibility to utilize scintillation arrays with pixel dimension less than 1 mm, thus achieving sub-millimeter spatial resolution values. The last technological advance is a PSPMT with Flat Panel structure, named H8500. Its dimension is 50 x 50 mm 2 with a narrow peripheral dead zone to place closely different modules achieving large detection areas. In this paper the technological development of different PSPMT generations is reviewed and some measurements of the first Flat Panel PMT prototype are presented and compared with ones from previous generation. Flat Panel PMT could be the best trade-off between compactness, large detection areas, effective area (packing density) and imaging performance

  10. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Science.gov (United States)

    Starkenburg, Daken J.; Johns, Paul M.; Baciak, James E.; Nino, Juan C.; Xue, Jiangeng

    2017-12-01

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.18 μGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  11. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Energy Technology Data Exchange (ETDEWEB)

    Starkenburg, Daken J. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Johns, Paul M. [Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Detection Systems Group, Pacific Northwest National Laboratory, Richland, Washington 99354, USA; Baciak, James E. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Nino, Juan C. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Xue, Jiangeng [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA

    2017-12-14

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  12. Energy resolution measurements of LaBr3:Ce scintillating crystals with an ultra-high quantum efficiency photomultiplier tube

    International Nuclear Information System (INIS)

    Pani, R.; Cinti, M.N.; Scafe, R.; Pellegrini, R.; Vittorini, F.; Bennati, P.; Ridolfi, S.; Lo Meo, S.; Mattioli, M.; Baldazzi, G.; Pisacane, F.; Navarria, F.; Moschini, G.; Boccaccio, P.; Orsolini Cencelli, V.; Sacco, D.

    2009-01-01

    The performance of the new prototype of high quantum efficiency PMT (43% at 380 nm), Hamamatsu R7600U-200, was studied coupled to a LaBr 3 :Ce crystal with the size of o12.5 mmx12.5 mm. The energy resolution results were compared with ones from two PMTs, Hamamatsu R7600U and R6231MOD, with 22% and 30% quantum efficiency (QE), respectively. Moreover, the photodetectors were equipped with tapered and un-tapered voltage dividers to study the non-linearity effects on pulse height distribution, due to very high peak currents induced in the PMT by the fast and intense light pulse of LaBr 3 :Ce. The results show an energy resolution improvement with UBA PMT of about 20%, in the energy range of 80-662 keV, with respect to the BA one.

  13. Study of multianode photomultipliers for the electromagnetic calorimeter preshower read out of the LHCb experiment

    CERN Document Server

    Aguiló, Ernest; Gascon, David; Ajaltouni, Ziad J; Böhner, G; Cârloganu, C; Cornat, R; Crouau, M; Deschamps, O; Henrard, P; Lecoq, J; Lefèvre, R; Monteil, S; Perret, P; Rimbault, C

    2003-01-01

    The LHCb experiment will study the CP symmetry violation in the system of the beauty particles. The detector is a 20-m-long spectrometer, to be installed on the proton-proton collider LHC. Of major importance for the level 0 trigger is the preshower of the electromagnetic calorimeter designed to discriminate between electrons, hadrons and photons. The preshower cells consist of a two- radiation-length lead sheet located between two plastic scintillator planes. The scintillation light is extracted with wavelength-shifting fibres. The best candidates to read out the light of the 6000 detector cells are multianode photomultipliers. The HAMAMATSU photomultiplier R5900-00-M64 has been studied and its responses in terms of gain, linearity, uniformity within and between the anodes and cross-talk between the channels are addressed in this document.

  14. Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array

    International Nuclear Information System (INIS)

    Álvarez, V; Cárcel, S; Cervera, A; Díaz, J; Ferrario, P; Gil, A; Borges, F I G; Conde, C A N; Dias, T H V T; Fernandes, L M P; Freitas, E D C; Castel, J; Cebrián, S; Dafni, T; Egorov, M; Gehman, V M; Goldschmidt, A; Esteve, R; Evtoukhovitch, P; Ferreira, A L

    2013-01-01

    NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current configuration the apparatus fully implements the NEXT-100 design concept. This is an asymmetric TPC, with an energy plane made of photomultipliers and a tracking plane made of silicon photomultipliers (SiPM) coated with TPB. The detector in this new configuration has been used to reconstruct the characteristic signature of electrons in dense gas, demonstrating the ability to identify the MIP and ''blob'' regions. Moreover, the SiPM tracking plane allows for the definition of a large fiducial region in which an excellent energy resolution of 1.82% FWHM at 511 keV has been measured (a value which extrapolates to 0.83% at the xenon Q ββ )

  15. Analysis of single-photon time resolution of FBK silicon photomultipliers

    International Nuclear Information System (INIS)

    Acerbi, Fabio; Ferri, Alessandro; Gola, Alberto; Zorzi, Nicola; Piemonte, Claudio

    2015-01-01

    We characterized and analyzed an important feature of silicon photomultipliers: the single-photon time resolution (SPTR). We characterized the SPTR of new RGB (Red–Green–Blue) type Silicon Photomultipliers and SPADs produced at FBK (Trento, Italy), studying its main limiting factors. We compared time resolution of 1×1 mm 2 and 3×3 mm 2 SiPMs and a single SiPM cell (i.e. a SPAD with integrated passive-quenching), employing a mode-locked pulsed laser with 2-ps wide pulses. We estimated the contribution of front-end electronic-noise, of cell-to-cell uniformity, and intrinsic cell time-resolution. At a single-cell level, we compared the results obtained with different layouts. With a circular cell with a top metallization covering part of the edge and enhancing the signal extraction, we reached ~20 ps FWHM of time resolution

  16. Analysis of single-photon time resolution of FBK silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Acerbi, Fabio, E-mail: acerbi@fbk.eu; Ferri, Alessandro; Gola, Alberto; Zorzi, Nicola; Piemonte, Claudio

    2015-07-01

    We characterized and analyzed an important feature of silicon photomultipliers: the single-photon time resolution (SPTR). We characterized the SPTR of new RGB (Red–Green–Blue) type Silicon Photomultipliers and SPADs produced at FBK (Trento, Italy), studying its main limiting factors. We compared time resolution of 1×1 mm{sup 2} and 3×3 mm{sup 2} SiPMs and a single SiPM cell (i.e. a SPAD with integrated passive-quenching), employing a mode-locked pulsed laser with 2-ps wide pulses. We estimated the contribution of front-end electronic-noise, of cell-to-cell uniformity, and intrinsic cell time-resolution. At a single-cell level, we compared the results obtained with different layouts. With a circular cell with a top metallization covering part of the edge and enhancing the signal extraction, we reached ~20 ps FWHM of time resolution.

  17. Development of Silicon Photomultipliers and their Applications to GlueX Calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Elton S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-07-01

    The GlueX experiment is a photoproduction experiment in Hall D at Jefferson Lab that is being commissioned for use with the new 12 GeV accelerator. The purpose of the experiment is to search for Hybrid mesons, which are mesons with quark and gluon degrees of freedom. The barrel calorimeter of GlueX is instrumented with 4000 large-area (1.2 x1.2 cm2) silicon photomultipliers (SiPMs). These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment they operate in magnetic fields exceeding 1T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs). We will give an overview of this new technology as well as the experience gained during two commissioning periods with beam.

  18. Time-domain diffuse optical tomography using silicon photomultipliers: feasibility study

    OpenAIRE

    Di Sieno, Laura; Zouaoui, Judy; Hervé, Lionel; Pifferi, Antonio; Farina, Andrea; Martinenghi, Edoardo; Derouard, Jacques; Dinten, Jean-Marc; Dalla Mora, Alberto

    2016-01-01

    International audience; Silicon photomultipliers (SiPMs) have been very recently introduced as the most promising detectors in the field of diffuse optics, in particular due to the inherent low cost and large active area. We also demonstrate the suitability of SiPMs for time-domain diffuse optical tomography (DOT). The study is based on both simulations and experimental measurements. Results clearly show excellent performances in terms of spatial localization of an absorbing perturbation, thu...

  19. An innovative silicon photomultiplier digitizing camera for gamma-ray astronomy

    Czech Academy of Sciences Publication Activity Database

    Heller, M.; Schioppa, E.jr.; Porcelli, A.; Pujadas, I.T.; Zietara, K.; della Volpe, D.; Montaruli, T.; Cadoux, F.; Favre, Y.; Aguilar, J.A.; Christov, A.; Prandini, E.; Rajda, P.; Rameez, M.; Bilnik, W.; Blocki, J.; Bogacz, L.; Borkowski, J.; Bulik, T.; Frankowski, A.; Grudzinska, M.; Idzkowski, B.; Jamrozy, M.; Janiak, M.; Kasperek, J.; Lalik, K.; Lyard, E.; Mach, E.; Mandát, Dušan; Marszalek, A.; Medina Miranda, L. D.; Michałowski, J.; Moderski, R.; Neronov, A.; Niemiec, J.; Ostrowski, M.; Pasko, P.; Pech, Miroslav; Schovánek, Petr; Seweryn, K.; Sliusar, V.; Skowron, K.; Stawarz, L.; Stodulska, M.; Stodulski, M.; Walter, R.; Wiecek, M.; Zagdanski, A.

    2017-01-01

    Roč. 77, č. 1 (2017), s. 1-31, č. článku 47. ISSN 1434-6044 R&D Projects: GA MŠk LE13012; GA MŠk LG14019 Institutional support: RVO:68378271 Keywords : silicon photomultiplier * digitizing camera * gamma-ray astronomy Subject RIV: BF - Elementary Particles and High Energy Physics OBOR OECD: Particles and field physics Impact factor: 5.331, year: 2016

  20. Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems

    Energy Technology Data Exchange (ETDEWEB)

    Martinenghi, E., E-mail: edoardo.martinenghi@polimi.it; Di Sieno, L.; Contini, D.; Dalla Mora, A. [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Sanzaro, M. [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Pifferi, A. [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci 32, 20133 Milano (Italy)

    2016-07-15

    We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm{sup 2} together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).

  1. Tracheostomy tube - eating

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000464.htm Tracheostomy tube - eating To use the sharing features on ... when you swallow foods or liquids. Eating and Tracheostomy Tubes When you get your tracheostomy tube, or ...

  2. Eustachian tube patency

    Science.gov (United States)

    Eustachian tube patency refers to how much the eustachian tube is open. The eustachian tube runs between the middle ear and the throat. It controls the pressure behind the eardrum and middle ear space. This helps keep ...

  3. Study of sampling rate influence on neutron-gamma discrimination with stilbene coupled to a silicon photomultiplier.

    Science.gov (United States)

    Zhang, Jinglong; Moore, Michael E; Wang, Zhonghai; Rong, Zhou; Yang, Chaowen; Hayward, Jason P

    2017-10-01

    Choosing a digitizer with an appropriate sampling rate is often a trade-off between performance and economy. The influence of sampling rates on the neutron-gamma Pulse Shape Discrimination (PSD) with a solid stilbene scintillator coupled to a Silicon Photomultiplier was investigated in this work. Sampling rates from 125MSPS to 2GSPS from a 10-bit digitizer were used to collect detector pulses produced by the interactions of a Cf-252 source. Due to the decreased signal-to-noise ratio (SNR), the PSD performance degraded with reduced sampling rates. The reason of PSD performance degradation was discussed. Then, an efficient combination of filtering and digital signal processing (DSP) was then applied to suppress the timing noise and electronic background noise. The results demonstrate an improved PSD performance especially at low sampling rates, down to 125MSPS. Using filtering and DSP, the ascribed Figure of Merit (FOM) at 125keV ee (± 10keV ee ) increased from 0.95 to 1.02 at 125MSPS. At 300keV ee and above, all the FOMs are better than 2.00. Our study suggests that 250MSPS is a good enough sampling rate for neutron-gamma discrimination in this system in order to be sensitive to neutrons at and above ~ 125keV ee . Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Heat exchanger tube mounts

    Science.gov (United States)

    Wolowodiuk, W.; Anelli, J.; Dawson, B.E.

    1974-01-01

    A heat exchanger in which tubes are secured to a tube sheet by internal bore welding is described. The tubes may be moved into place in preparation for welding with comparatively little trouble. A number of segmented tube support plates are provided which allow a considerable portion of each of the tubes to be moved laterally after the end thereof has been positioned in preparation for internal bore welding to the tube sheet. (auth)

  5. Photoelectron backscattering from silicon anodes of hybrid photodetector tubes

    CERN Document Server

    D'Ambrosio, C

    2000-01-01

    The impact of photoelectron backscattering on spectral distributions measured with hybrid photodetector tubes has been calculated. The calculations are based on the backscattering coefficient mu , the average number of photoelectrons N/sub phel/ emitted from the photocathode, and on the distribution of the fractional photoelectron energy q absorbed in silicon during the backscattering process. We obtained the following results: the average number of absorbed (measured) photoelectrons N/sub meas/ in the silicon anode amounts to ~88% of the incident N/sub phel/. Photoelectron- and gamma-absorption peaks are broadened by a factor 1.043 due to backscattering. As an example, for photomultiplier tubes, this broadening can amount to an average factor of 1.18 due to statistic and gain fluctuations on the dynode chain. (15 refs).

  6. Phase I study of combination of vorinostat, carboplatin, and gemcitabine in women with recurrent, platinum-sensitive epithelial ovarian, fallopian tube, or peritoneal cancer.

    Science.gov (United States)

    Matulonis, Ursula; Berlin, Suzanne; Lee, Hang; Whalen, Christin; Obermayer, Elizabeth; Penson, Richard; Liu, Joyce; Campos, Susana; Krasner, Carolyn; Horowitz, Neil

    2015-08-01

    Combining histone deacetylase inhibitors and chemotherapy is synergistic. This phase I study combined escalating vorinostat doses with constant doses of carboplatin and gemcitabine for the treatment of recurrent platinum-sensitive ovarian cancer. The objectives of this study were to determine the maximally tolerated dose of this combination; secondary objectives included preliminary response rate of this regimen and toxicity profile. Fifteen patients with relapsed ovarian cancer were enrolled into this phase I study. Doses of carboplatin and gemcitabine were AUC 4 on day 1 and 1000 mg/m(2) on days 1 and 8, respectively; cycles were administered every 21 days. Vorinostat was tested using four different schedules. The first dose level (DL A) tested vorinostat as daily oral dosing from days 1 to 14. DL B tested twice daily (BID) vorinostat dosing on days 1-3 and 8-10. DL C tested BID vorinostat dosing on days 1, 2, 8, and 9, starting vorinostat 1 day prior to initiation of carboplatin and gemcitabine, and DL D tested vorinostat on days 1 and 2 with chemotherapy starting on day 2. All four DLs tested resulted in dose-limiting toxicities, and no MTD was determined. Toxicities were mostly hematologic. Seven patients were evaluable for RECIST assessment, and six of them had partial responses (PR) via RECIST. Combination of carboplatin, gemcitabine, and vorinostat has activity in relapsed platinum-sensitive ovarian cancer, but was difficult to combine because of hematologic toxicities in this phase I study. No maximally tolerated dose was found, and the study was terminated early.

  7. Direction sensitive neutron detector

    Science.gov (United States)

    Ahlen, Steven; Fisher, Peter; Dujmic, Denis; Wellenstein, Hermann F.; Inglis, Andrew

    2017-01-31

    A neutron detector includes a pressure vessel, an electrically conductive field cage assembly within the pressure vessel and an imaging subsystem. A pressurized gas mixture of CF.sub.4, .sup.3He and .sup.4He at respective partial pressures is used. The field cage establishes a relatively large drift region of low field strength, in which ionization electrons generated by neutron-He interactions are directed toward a substantially smaller amplification region of substantially higher field strength in which the ionization electrons undergo avalanche multiplication resulting in scintillation of the CF.sub.4 along scintillation tracks. The imaging system generates two-dimensional images of the scintillation patterns and employs track-finding to identify tracks and deduce the rate and direction of incident neutrons. One or more photo-multiplier tubes record the time-profile of the scintillation tracks permitting the determination of the third coordinate.

  8. Tube holding system

    International Nuclear Information System (INIS)

    Cunningham, R.C.

    1978-01-01

    A tube holding rig is described for the lateral support of tubes arranged in tight parcels in a heat exchanger. This tube holding rig includes not less than two tube supporting assemblies, with a space between them, located crosswise with respect to the tubes, each supporting assembly comprising a first set of parallel components in contact with the tubes, whilst a second set of components is also in contact with the tubes. These two sets of parts together define apertures through which the tubes pass [fr

  9. Effect of carbon nano tube working electrode thickness on charge transport kinetics and photo-electrochemical characteristics of dye-sensitized solar cells

    Science.gov (United States)

    Gacemi, Yahia; Cheknane, Ali; Hilal, Hikmat S.

    2018-02-01

    Physiochemical processes at the photo-electrode and the counter electrode of dye sensitized solar cells (DSSCs) involving having carbon nanotubes (CNTs) instead of the TiO2 layer, within the working electrode, are simulated in this work. Attention is paid to find the effect of CNT layer thickness on photo-electrochemical (PEC) characteristics of the CNT-DSSCs. Comparison with other conventional TiO2-DSSC systems, taking into account the working electrode film thickness, is also described here. To achieve these goals, a model is presented to explain charge transport and electron recombination which involve electron photo-excitation in dye molecules, injection of electrons from the excited dye to CNT working electrode conduction band, diffusion of electrons inside the CNT electrode, charge transfer between oxidized dye and (I-) and recombination of electrons. The simulation is based on solving non-linear equations using the Newton-Raphson numerical method. This concept is proposed for modelling numerical Faradaic impedance at the photo-electrode and the platinum counter electrode. It then simulates the cell impedance spectrum describing the locus of the three semicircles in the Nyquist diagram. The transient equivalent circuit model is also presented based on optimizing current-voltage curves of CNT-DSSCs so as to optimize the fill factor (FF) and conversion efficiency (η). The results show that the simulated characteristics of CNT-DSSCs, with different active CNT layer thicknesses, are superior to conventional TiO2-DSSCs.

  10. Sensitivity and specificity of QuantiFERON-TB Gold Plus compared with QuantiFERON-TB Gold In-Tube and T-SPOT.TB on active tuberculosis in Japan.

    Science.gov (United States)

    Takasaki, Jin; Manabe, Toshie; Morino, Eriko; Muto, Yoshikazu; Hashimoto, Masao; Iikura, Motoyasu; Izumi, Shinyu; Sugiyama, Haruhito; Kudo, Koichiro

    2018-03-01

    The QuantiFERON-TB Gold Plus (QFT-Plus) was introduced in 2015 as a new generation of interferon-gamma release assays (IGRAs) designed to detect Mycobacterium tuberculosis infection (TB). Examination of its diagnostic accuracy is crucial before it is launched in Japan. We examined 99 patients with laboratory-confirmed active TB (patients) and 117 healthy volunteers with no risk of TB infection (controls) at a medical center in Tokyo, Japan. Blood samples were collected from both the patients and controls and tested using three types of IGRAs: the QFT-Plus, the QuantiFERON-TB Gold In-Tube (QFT-GIT), and the T-SPOT.TB (T-SPOT). The sensitivity and specificity of each IGRA were examined and compared. The sensitivity of the QFT-Plus was 98.9% (95% confidence interval [CI], 0.934-0.998) and similar to that of the QFT-GIT (97.9%; 95% CI, 0.929-0.998) and T-SPOT (96.9%; 95% CI, 0.914-0.994). The specificity of the QFT-Plus was the same as that of the QFT-GIT and T-SPOT (98.1%; 95% CI, 0.934-0.998). One patient with uncontrolled diabetes mellitus showed negative results on all three IGRAs. The QFT-Plus showed a high degree of agreement with the QFT-GIT and T-SPOT, with high sensitivity and specificity. Severe diabetes mellitus may influence the results of IGRAs. Larger studies are needed to validate the accuracy of the GFT-Plus and determine whether it can contribute as adjunctive method for the early diagnosis of active TB in Japan. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  11. Impact of long-pass interferential filters on dark current and background light rejection in Silicon Photomultipliers

    Science.gov (United States)

    Mazzillo, M.; Sciuto, A.; Libertino, S.; Lombardo, S.; Fallica, G.

    2018-02-01

    There is an increasing interest in using Silicon Photomultipliers (SiPMs) in emerging applications where the detectors have to operate in ambient environment with high sensitivity and fast timing response in combination with narrow bandwidth light emitting sources like LEDs or VCSELs. The need to use large area detectors for optimizing the light collection efficiency, due to the low optical fluxes to be usually detected, imposes the optimization of the SiPM performance in specific wavelength ranges (usually visible or near infrared), to fully exploit the single photon sensitivity of these detectors and not to reduce at the same time their dynamic range. The use of proper optical long-pass filters on the detector's package can represent a suitable way to reach both these targets, through the reduction of environmental light absorption. Here we present the preliminary results obtained from the characterization of n+-p SiPMs with commercial long-pass filters with increasing cut-on wavelength in the range 500 nm-900 nm glued on the top side of the detector's package. The performance of the detectors has been evaluated in terms of dark current variation induced by the use of the filters and background light rejection under the illumination of white fluorescent lamps. The relevant reduction observed in the dark current (up to 90% at 13 V overvoltage) and the consistent reduction of stray light absorption (up to 90% at 3 V overvoltage with a 900 nm cut-on wavelength long-pass filter) are the main characterization results obtained and shown in this paper.

  12. A sampling ultra-high-speed streak camera based on the use of a unique photomultiplier

    International Nuclear Information System (INIS)

    Marode, Emmanuel

    An apparatus reproducing the ''streak'' mode of a high-speed camera is proposed for the case of a slit AB whose variations in luminosity are repetitive. A photomultiplier, analysing the object AB point by point, and a still camera, photographing a slit fixed on the oscilloscope screen parallel to the sweep direction are placed on a mobile platform P. The movement of P assures a time-resolved analysis of AB. The resolution is of the order of 2.10 -9 s, and can be improved [fr

  13. Tine-of-flight characteristics of the scintillation counters with microgrid photomultipliers

    International Nuclear Information System (INIS)

    Akindinov, A.V.; Kiselev, Yu.T.; Martem'yanov, A.N.; Ushakov, V.I.

    2003-01-01

    The time-of-flight characteristics of the scintillation counters with the microgrid dynodes magnetically stable photomultipliers are measured. The scintillation counters with thin plastic scintillators 1.3 and 5 mm thick were intended for operation in the relatively strong scattered magnetic fields up to several kilogauss. The measurements were accomplished in the proton synchrotron beams with the protons and π + -mesons pulses of 0.63 and 1.03 GeV/s and with the π - -mesons pulses of 1.28 GeV/s. The time resolutions in the interval of 45-180 ps are obtained [ru

  14. Time-domain diffuse optical tomography using silicon photomultipliers: feasibility study.

    Science.gov (United States)

    Di Sieno, Laura; Zouaoui, Judy; Hervé, Lionel; Pifferi, Antonio; Farina, Andrea; Martinenghi, Edoardo; Derouard, Jacques; Dinten, Jean-Marc; Mora, Alberto Dalla

    2016-11-01

    Silicon photomultipliers (SiPMs) have been very recently introduced as the most promising detectors in the field of diffuse optics, in particular due to the inherent low cost and large active area. We also demonstrate the suitability of SiPMs for time-domain diffuse optical tomography (DOT). The study is based on both simulations and experimental measurements. Results clearly show excellent performances in terms of spatial localization of an absorbing perturbation, thus opening the way to the use of SiPMs for DOT, with the possibility to conceive a new generation of low-cost and reliable multichannel tomographic systems.

  15. Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.; Chen, Ningshun; Chokheli, Davit; Davydov, Yuri; Dukes, E. Craig; Dychkant, Alexsander; Ehrlich, Ralf; Francis, Kurt; Frank, M. J.; Glagolev, Vladimir; Group, Craig; Hansen, Sten; Magill, Stephen; Oksuzian, Yuri; Pla-Dalmau, Anna; Rubinov, Paul; Simonenko, Aleksandr; Song, Enhao; Stetzler, Steven; Wu, Yongyi; Uzunyan, Sergey; Zutshi, Vishnu

    2018-05-01

    Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120\\,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\\&D program.

  16. Single photon timing resolution and detection efficiency of the IRST silicon photo-multipliers

    International Nuclear Information System (INIS)

    Collazuol, G.; Ambrosi, G.; Boscardin, M.; Corsi, F.; Dalla Betta, G.F.; Del Guerra, A.; Dinu, N.; Galimberti, M.; Giulietti, D.; Gizzi, L.A.; Labate, L.; Llosa, G.; Marcatili, S.; Morsani, F.; Piemonte, C.; Pozza, A.; Zaccarelli, L.; Zorzi, N.

    2007-01-01

    Silicon photo-multipliers (SiPM) consist in matrices of tiny, passive quenched avalanche photo-diode cells connected in parallel via integrated resistors and operated in Geiger mode. Novel types of SiPM are being developed at FBK-IRST (Trento, Italy). Despite their classical shallow junction n-on-p structure the devices are unique in their enhanced photo-detection efficiency (PDE) for short-wavelengths and in their low level of dark rate and excess noise factor. After a summary of the extensive SiPM characterization we will focus on the study of PDE and the single photon timing resolution

  17. Multiplex Nested Reverse Transcription-Polymerase Chain Reaction in a Single Tube for Sensitive and Simultaneous Detection of Four RNA Viruses and Pseudomonas savastanoi pv. savastanoi in Olive Trees.

    Science.gov (United States)

    Bertolini, Edson; Olmos, Antonio; López, María M; Cambra, Mariano

    2003-03-01

    ABSTRACT A multiplex nested reverse transcription-polymerase chain reaction (RT-PCR) in a single closed tube was developed for the simultaneous detection of four RNA viruses: Cucumber mosaic virus, Cherry leaf roll virus, Strawberry latent ringspot virus, and Arabis mosaic virus, and the bacterium Pseudomonas savastanoi pv. savastanoi. The method enabled, for the first time, the sensitive and simultaneous detection of RNA and DNA targets from plant viruses and a bacterium, saving time, decreasing risks of contamination, and reducing costs compared with conventional monospecific nested amplifications. The method was successfully coupled with colorimetric detection of amplicons using specific oligoprobes to simplify routine detection. Two hundred forty-five olive trees from 15 different cultivars were analyzed by multiplex RT-nested PCR coupled with colorimetric detection. Multiplex nested RT-PCR for viral detection increased the identification of positive trees by 8.1%. An uneven distribution of the viruses was observed in the infected trees. The bacterium was detected in 28.7% of the analyzed trees by the developed multiplex nested method and by a nested PCR previously developed. This powerful methodology could be applied to other models for the detection of several pathogens in a single assay.

  18. Fluid heating by current injection tubes; Chauffage de fluides par tubes a passage de courant

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, L.S. [Societe Parmilleux (France)

    1999-04-01

    Current injection tube technology may be applied in compact fluid heating installation with a very low level of thermal inertia. The technology is particularly suitable for heating heat-sensitive fluids or those with a tendency to foul other types of installations. Specific advantages of current injection tubes include the elimination of cold spots and their reduced volume requirements. (author)

  19. Development of high performance readout ASICs for silicon photomultipliers (SiPMs)

    International Nuclear Information System (INIS)

    Shen, Wei

    2012-01-01

    Silicon Photomultipliers (SiPMs) are novel kind of solid state photon detectors with extremely high photon detection resolution. They are composed of hundreds or thousands of avalanche photon diode pixels connected in parallel. These avalanche photon diodes are operated in Geiger Mode. SiPMs have the same magnitude of multiplication gain compared to the conventional photomultipliers (PMTs). Moreover, they have a lot of advantages such as compactness, relatively low bias voltage and magnetic field immunity etc. Special readout electronics are required to preserve the high performance of the detector. KLauS and STiC are two CMOS ASIC chips designed in particular for SiPMs. KLauS is used for SiPM charge readout applications. Since SiPMs have a much larger detector capacitance compared to other solid state photon detectors such as PIN diodes and APDs, a few special techniques are used inside the chip to make sure a descent signal to noise ratio for pixel charge signal can be obtained. STiC is a chip dedicated to SiPM time-of-flight applications. High bandwidth and low jitter design schemes are mandatory for such applications where time jitter less than tens of picoseconds is required. Design schemes and error analysis as well as measurement results are presented in the thesis.

  20. Characterization studies of Silicon Photomultipliers and crystals matrices for a novel time of flight PET detector

    CERN Document Server

    Auffray, Etiennette; Cortinovis, Daniele; Doroud, Katayoun; Garutti, Erika; Lecoq, Paul; Liu, Zheng; Martinez, Rosana; Paganoni, Marco; Pizzichemi, Marco; Silenzi, Alessandro; Xu, Chen; Zvolský, Milan

    2015-01-01

    This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration aims to integrate Time-Of-Flight PET with ultrasound endoscopy in a novel multimodal device, capable to support the development of new biomarkers for prostate and pancreatic tumors. The detector consists in two parts: a PET head mounted on an ultrasound probe and an external PET plate. The challenging goal of 1 mm spatial resolution for the PET image requires a detector with small crystal size, and therefore high channel density: 4096 LYSO crystals individually readout by Silicon Photomultipliers (SiPM) make up the external plate. The quality and properties of these components must be assessed before the assembly. The dark count rate, gain, breakdown voltage and correlated noise of the SiPMs are measured, while the LYSO crystals are evaluated in terms of light yield and en...

  1. Analytical models of probability distribution and excess noise factor of solid state photomultiplier signals with crosstalk

    International Nuclear Information System (INIS)

    Vinogradov, S.

    2012-01-01

    Silicon Photomultipliers (SiPM), also called Solid State Photomultipliers (SSPM), are based on Geiger mode avalanche breakdown that is limited by a strong negative feedback. An SSPM can detect and resolve single photons due to the high gain and ultra-low excess noise of avalanche multiplication in this mode. Crosstalk and afterpulsing processes associated with the high gain introduce specific excess noise and deteriorate the photon number resolution of the SSPM. The probabilistic features of these processes are widely studied because of its significance for the SSPM design, characterization, optimization and application, but the process modeling is mostly based on Monte Carlo simulations and numerical methods. In this study, crosstalk is considered to be a branching Poisson process, and analytical models of probability distribution and excess noise factor (ENF) of SSPM signals based on the Borel distribution as an advance on the geometric distribution models are presented and discussed. The models are found to be in a good agreement with the experimental probability distributions for dark counts and a few photon spectrums in a wide range of fired pixels number as well as with observed super-linear behavior of crosstalk ENF.

  2. Performance of CATIROC: ASIC for smart readout of large photomultiplier arrays

    Science.gov (United States)

    Blin, S.; Callier, S.; Conforti Di Lorenzo, S.; Dulucq, F.; De La Taille, C.; Martin-Chassard, G.; Seguin-Moreau, N.

    2017-03-01

    CATIROC (Charge And Time Integrated Read Out Chip) is a complete read-out chip manufactured in AustriaMicroSystem (AMS) SiGe 0.35 μm technology, designed to read arrays of 16 photomultipliers (PMTs). It is an upgraded version of PARISROC2 [1] designed in 2010 in the context of the PMm2 (square meter PhotoMultiplier) project [2]. CATIROC is a SoC (System on Chip) that processes analog signals up to the digitization and sparsification to reduce the cost and cable number. The ASIC is composed of 16 independent channels that work in triggerless mode, auto-triggering on the single photo-electron. It provides a charge measurement up to 400 photoelectrons (70 pC) on two scales of 10 bits and a timing information with an accuracy of 200 ps rms. The ASIC was sent for fabrication in February 2015 and then received in September 2015. It is a good candidate for two Chinese projects (LHAASO and JUNO). The architecture and the measurements will be detailed in the paper.

  3. Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Hatazawa, Jun; Aoki, Masaaki; Sugiyama, Eiji; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku

    2011-01-01

    The silicon-photomultiplier (Si-PM) is a promising photodetector, especially for integrated PET/MRI systems, due to its small size, high gain, and low sensitivity to static magnetic fields. The major problem using a Si-PM-based PET system within the MRI system is the interference between the PET and MRI units. We measured the interference by combining a Si-PM-based PET system with a permanent-magnet MRI system. When the RF signal-induced pulse height exceeded the lower energy threshold level of the PET system, interference between the Si-PM-based PET system and MRI system was detected. The prompt as well as the delayed coincidence count rates of the Si-PM-based PET system increased significantly. These noise counts produced severe artifacts on the reconstructed images of the Si-PM-based PET system. In terms of the effect of the Si-PM-based PET system on the MRI system, although no susceptibility artifact was observed on the MR images, electronic noise from the PET detector ring was detected by the RF coil and reduced the signal-to-noise ratio (S/N) of the MR images. The S/N degradation of the MR images was reduced when the distance between the RF coil and the Si-PM-based PET system was increased. We conclude that reducing the interference between the PET and MRI systems is essential for achieving the optimum performance of integrated Si-PM PET/MRI systems.

  4. Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi [Kobe City College of Technology, Kobe (Japan); Watabe, Hiroshi; Kanai, Yasukazu; Hatazawa, Jun [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine, Osaka (Japan); Aoki, Masaaki; Sugiyama, Eiji [Neomax Engineering, Takasaki (Japan); Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku, E-mail: s-yama@kobe-kosen.ac.jp [Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine, Osaka (Japan)

    2011-07-07

    The silicon-photomultiplier (Si-PM) is a promising photodetector, especially for integrated PET/MRI systems, due to its small size, high gain, and low sensitivity to static magnetic fields. The major problem using a Si-PM-based PET system within the MRI system is the interference between the PET and MRI units. We measured the interference by combining a Si-PM-based PET system with a permanent-magnet MRI system. When the RF signal-induced pulse height exceeded the lower energy threshold level of the PET system, interference between the Si-PM-based PET system and MRI system was detected. The prompt as well as the delayed coincidence count rates of the Si-PM-based PET system increased significantly. These noise counts produced severe artifacts on the reconstructed images of the Si-PM-based PET system. In terms of the effect of the Si-PM-based PET system on the MRI system, although no susceptibility artifact was observed on the MR images, electronic noise from the PET detector ring was detected by the RF coil and reduced the signal-to-noise ratio (S/N) of the MR images. The S/N degradation of the MR images was reduced when the distance between the RF coil and the Si-PM-based PET system was increased. We conclude that reducing the interference between the PET and MRI systems is essential for achieving the optimum performance of integrated Si-PM PET/MRI systems.

  5. Tracheostomy tube - speaking

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000465.htm Tracheostomy tube - speaking To use the sharing features on ... are even speaking devices that can help you. Tracheostomy Tubes and Speaking Air passing through vocal cords ( ...

  6. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  7. Neural Tube Defects

    Science.gov (United States)

    Neural tube defects are birth defects of the brain, spine, or spinal cord. They happen in the ... that she is pregnant. The two most common neural tube defects are spina bifida and anencephaly. In ...

  8. Jejunostomy feeding tube

    Science.gov (United States)

    ... may replace the tube every now and then. Cleaning the Skin Around the J-tube To clean ... this important distinction for online health information and services. Learn more about A.D.A.M.'s editorial ...

  9. Chemical milling of zircaloy tubing to produce integral OD spiral finned tubes. AWBA development program

    Science.gov (United States)

    Horwood, W. A.

    1982-02-01

    A detailed process description is provided for producing integral spiral fins on the outside surface of Zircaloy nuclear fuel cladding tubes by masking with pressure sensitive tape strips and then chemical milling (pickling) the tube wall between the tape strips to leave the fins in relief. Fins up to 0.020 inch high by 0.05 to 0.12 inch wide were consistently produced on tubes having wall thickness of 0.008 inch or greater after fin pickling. Wall thickness uniformity was excellent. Information is provided on tube surface preparation to maximize tape mask adhesion time during pickling, acid chemistry control to prevent local tube wall thinning near the fin, and pickling techniques to promote uniform material removal. Simple fixture designs are described for quickly and conveniently applying the tape strips to the tube wall in an accurate spiral.

  10. Optimizing Tube Precurvature to Enhance Elastic Stability of Concentric Tube Robots.

    Science.gov (United States)

    Ha, Junhyoung; Park, Frank C; Dupont, Pierre E

    2017-02-01

    Robotic instruments based on concentric tube technology are well suited to minimally invasive surgery since they are slender, can navigate inside small cavities and can reach around sensitive tissues by taking on shapes of varying curvature. Elastic instabilities can arise, however, when rotating one precurved tube inside another. In contrast to prior work that considered only tubes of piecewise constant precurvature, we allow precurvature to vary along the tube's arc length. Stability conditions for a planar tube pair are derived and used to formulate an optimal design problem. An analytic formulation of the optimal precurvature function is derived that achieves a desired tip orientation range while maximizing stability and respecting bending strain limits. This formulation also includes straight transmission segments at the proximal ends of the tubes. The result, confirmed by both numerical and physical experiment, enables designs with enhanced stability in comparison to designs of constant precurvature.

  11. Stabilization Strategies for Drift Tube Linacs

    CERN Document Server

    AUTHOR|(CDS)2085420; Lamehi Rashti, Mohammad

    The average axial electric fields in drift tube linac cavities are known to be sensitive with respect to the perturbation errors. Postcoupler is a powerful stabilizer devices that is used to reduce this sensitivity of average axial field. Postcouplers are the cylindrical rod which is extended from cavity wall toward the drift tube without touching the drift tube surface. Postcouplers need to be adjusted to the right length to stabilize the average axial field. Although postcouplers are used successfully in many projects, there is no straightforward procedure for postcouplers adjustment and it has been done almost based on trial and errors. In this thesis, the physics and characteristics of postcouplers has been studied by using an equivalent circuit model and 3D finite element method calculations. Finally, a straightforward and accurate method to adjust postcouplers has been concluded. The method has been verified by using experimental measurements on CERN Linac4 drift tube linac cavities.

  12. Nasogastric and feeding tubes.

    Science.gov (United States)

    Gharib, Ahmed M; Stern, Eric J; Sherbin, Vandy L; Rohrmann, Charles A

    1996-05-01

    Preview The authors' experience in a radiology department suggested to them that there is a wide range of beliefs among practitioners regarding proper placement of nasogastric and feeding tubes. Improper positioning can cause serious problems, as they explain. Indications for different tube positions, complications of incorrect tube placement, and directions for proper positioning are discussed and illustrated.

  13. Failure analysis of retired steam generator tubings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Pyo; Kim, J. S.; Hwang, S. S. and others

    2005-04-15

    Degradation of steam generator leads to forced outage and extension of outage, which causes increase in repair cost, cost of purchasing replacement power and radiation exposure of workers. Steam generator tube rupture incident occurred in Uljin 4 in 2002, which made public sensitive to nuclear power plant. To keep nuclear energy as a main energy source, integrity of steam generator should be demonstrated. Quantitative relationship between ECT(eddy current test) signal and crack size is needed in assesment of integrity of steam generator in pressurized water reactor. However, it is not fully established for application in industry. Retired steam generator of Kori 1 has many kinds of crack such as circumferential and axial primary water stress corrosion crack and outer diameter stress corrosion crack(ODSCC). So, it can be used in qualifying and improving ECT technology and in condition monitoring assesment for crack detected in ISI(in service inspection). In addition, examination of pulled tube of Kori 1 retired steam generator will give information about effectiveness of non welded sleeving technology which was employed to repair defect tubes and remedial action which was applied to mitigate ODSCC. In this project, hardware such as semi hot lab. for pulled tube examination and modification transportation cask for pulled tube and software such as procedure of transportation of radioactive steam generator tube and non-destructive and destructive examination of pulled tube were established. Non-destructive and destructive examination of pulled tubes from Kori 1 retired steam generator were performed in semi hot lab. Remedial actions applied to Kori 1 retired steam generator, PWSCC trend and bulk water chemistry and crevice chemistry in Kori 1 were evaluated. Electrochemical decontamination technology for pulled tube was developed to reduce radiation exposure and enhance effectiveness of pulled tube examination. Multiparameter algorithm developed at ANL, USA was

  14. 21 CFR 868.5800 - Tracheostomy tube and tube cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheostomy tube and tube cuff. 868.5800 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5800 Tracheostomy tube and tube cuff. (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a...

  15. Short and long range gain monitoring of photomultipliers by means of a light pulser and an optical fibers bunch

    International Nuclear Information System (INIS)

    Besson, P.

    1989-01-01

    The gain monitoring of 8 XP3462 photomultipliers has been studied during a period of 3 months with a spark gap as a light pulser, an optical fibres bunch and 3 reference detectors. One of the reference PM is monitored thanks to a cristal of NaI irradiated by an 241 Am radioactive source, whereas the photodiode and its associated electronic is monitored thanks to a 57 Co source directly coupled to the junction. Two experimental methods have been tested. First the short term method consists in estimating several means of charge distributions and supposes the stability of different optical parameters like quantum efficiency or photoelectrons collection efficiency. The long term method consists in estimating several variances of charge distributions and supposes the validity, at first order, of photomultipliers' equations. In spite of unpropitious experimental conditions (tension switch off, no climatisation..), our results indicate that the short term method provides a precision of about 0.5% for the relative gain value but only during a short period which has been of 20 days. The long term method provides a precision of about 1.5% but is remained available during the 3 months of our experiment. This study has been developed for the new Neutrino oscillation program taking place near the Bugey nuclear plant and using 600 photomultipliers. The conclusions mentioned above are nevertheless valid for any particle detectors using photomultipliers [fr

  16. The Strip Silicon Photo-Multiplier: An innovation for enhanced time and position measurement

    Energy Technology Data Exchange (ETDEWEB)

    Doroud, K., E-mail: Katayoun.Doroud@cern.ch [CERN, Geneva (Switzerland); Williams, M.C.S. [CERN, Geneva (Switzerland); INFN, Bologna (Italy); Yamamoto, K. [Solid State Division, Hamamatsu Photonics K.K., Hamamatsu (Japan)

    2017-05-01

    There is considerable R&D concerning precise time measurement from a variety of detectors, and in particular for the Silicon PhotoMultiplier (SiPM). In this paper we discuss a new geometry for the SiPM in the form of a strip. A strip can be read out at both end, with each end coupled to an individual TDC (time to digital converter). The time difference is related to the position of the firing SPAD along the length of the strip, while the average of the two times gives the time of the hit. Results from the testing of the first prototype Strip SiPMs are presented in this paper.

  17. Compact Quantum Random Number Generator with Silicon Nanocrystals Light Emitting Device Coupled to a Silicon Photomultiplier

    Science.gov (United States)

    Bisadi, Zahra; Acerbi, Fabio; Fontana, Giorgio; Zorzi, Nicola; Piemonte, Claudio; Pucker, Georg; Pavesi, Lorenzo

    2018-02-01

    A small-sized photonic quantum random number generator, easy to be implemented in small electronic devices for secure data encryption and other applications, is highly demanding nowadays. Here, we propose a compact configuration with Silicon nanocrystals large area light emitting device (LED) coupled to a Silicon photomultiplier to generate random numbers. The random number generation methodology is based on the photon arrival time and is robust against the non-idealities of the detector and the source of quantum entropy. The raw data show high quality of randomness and pass all the statistical tests in national institute of standards and technology tests (NIST) suite without a post-processing algorithm. The highest bit rate is 0.5 Mbps with the efficiency of 4 bits per detected photon.

  18. Characteristics of a prototype matrix of Silicon PhotoMultipliers (SiPM)

    Energy Technology Data Exchange (ETDEWEB)

    Dinu, N; Barrillon, P; Bazin, C; Bondil-Blin, S; Chaumat, V; Taille, C De La; Puill, V; Vagnucci, J F [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Belcari, N; Bisogni, M G; Guerra, A Del; Llosa, G; Marcatili, S [Universita di Pisa, Dipartimento di Fisica ' E. Fermi' , 56127 Pisa (Italy); Boscardin, M; Melchiorri, M; Piemonte, C; Tarolli, A; Zorzi, N [Fondazione Bruno Kessler (FBK-irst), 38050 Trento (Italy); Collazuol, G [Scuola Normale Superiore (SNS), 56127 Pisa (Italy)], E-mail: dinu@lal.in2p3.fr

    2009-03-15

    This work reports on the electrical (static and dynamic) as well as on the optical characteristics of a prototype matrix of Silicon Photomultipliers (SiPM). The prototype matrix consists of 4 x 4 SiPM's on the same substrat fabricated at FBK-irst (Trento, Italy). Each SiPM of the matrix has an area of 1 x 1mm{sup 2} and it is composed of 625 microcells connected in parallel. Each microcell of the SiPM is a GM-APD (n{sup +}/p junction on P+ substrate) with an area of 40 x 40 {mu}m{sup 2} connected in series with its integrated polysilicon quenching resistance. The static characteristics as breakdown voltage, quenching resistance, post-breakdown dark current as well as the dynamic characteristics as gain and dark count rate have been analysed. The photon detection efficiency as a function of wavelength and operation voltage has been also estimated.

  19. First results in the application of silicon photomultiplier matrices to small animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Llosa, G. [University of Pisa, Department of Physics, Pisa (Italy)], E-mail: gabriela.llosa@pi.infn.it; Belcari, N.; Bisogni, M.G. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy); Collazuol, G. [University of Pisa, Department of Physics, Pisa (Italy); Scuola Normale Superiore, Pisa (Italy); Marcatili, S. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy); Boscardin, M.; Melchiorri, M.; Tarolli, A.; Piemonte, C.; Zorzi, N. [FBK irst, Trento (Italy); Barrillon, P.; Bondil-Blin, S.; Chaumat, V.; La Taille, C. de; Dinu, N.; Puill, V.; Vagnucci, J-F. [Laboratoire de l' Accelerateur Lineaire, IN2P3-CNRS, Orsay (France); Del Guerra, A. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy)

    2009-10-21

    A very high resolution small animal PET scanner that employs matrices of silicon photomultipliers as photodetectors is under development at the University of Pisa and INFN Pisa. The first SiPM matrices composed of 16 (4x4)1mmx1mm pixel elements on a common substrate have been produced at FBK-irst, and are being evaluated for this application. The MAROC2 ASIC developed at LAL-Orsay has been employed for the readout of the SiPM matrices. The devices have been tested with pixelated and continuous LYSO crystals. The results show the good performance of the matrices and lead to the fabrication of matrices with 64 SiPM elements.

  20. Development of large-area silicon photomultiplier detectors for PET applications at FBK

    Energy Technology Data Exchange (ETDEWEB)

    Zorzi, Nicola, E-mail: zorzi@fbk.eu [Fondazione Bruno Kessler (FBK), Via Sommarive 18, I-38123 Trento Povo (Italy); Melchiorri, Mirko; Piazza, Alessandro; Piemonte, Claudio; Tarolli, Alessandro [Fondazione Bruno Kessler (FBK), Via Sommarive 18, I-38123 Trento Povo (Italy)

    2011-04-21

    This paper reports on the development of large-area silicon photomultiplier (SiPM) detectors specifically designed for positron emission tomography (PET) instruments. The sensors under study are monolithic arrays of two different types: a 2x2 array of {approx}4x4 mm{sup 2} elements and an 8x8 array of 1.5x1.5 mm{sup 2} pixels. These devices are characterized at wafer level by means of an automatic test procedure, consisting of current-voltage curves in forward and reverse bias. The tests allowed selection of functioning devices and evaluation of the uniformity of basic parameters. Results of the electrical characterization are reported showing that acceptable values of yield together with rather uniform distribution of parameters have been obtained. Reliability of produced SiPMs has been proved by long-term accelerated stress tests.

  1. First results in the application of silicon photomultiplier matrices to small animal PET

    International Nuclear Information System (INIS)

    Llosa, G.; Belcari, N.; Bisogni, M.G.; Collazuol, G.; Marcatili, S.; Boscardin, M.; Melchiorri, M.; Tarolli, A.; Piemonte, C.; Zorzi, N.; Barrillon, P.; Bondil-Blin, S.; Chaumat, V.; La Taille, C. de; Dinu, N.; Puill, V.; Vagnucci, J-F.; Del Guerra, A.

    2009-01-01

    A very high resolution small animal PET scanner that employs matrices of silicon photomultipliers as photodetectors is under development at the University of Pisa and INFN Pisa. The first SiPM matrices composed of 16 (4x4)1mmx1mm pixel elements on a common substrate have been produced at FBK-irst, and are being evaluated for this application. The MAROC2 ASIC developed at LAL-Orsay has been employed for the readout of the SiPM matrices. The devices have been tested with pixelated and continuous LYSO crystals. The results show the good performance of the matrices and lead to the fabrication of matrices with 64 SiPM elements.

  2. Compact Quantum Random Number Generator with Silicon Nanocrystals Light Emitting Device Coupled to a Silicon Photomultiplier

    Directory of Open Access Journals (Sweden)

    Zahra Bisadi

    2018-02-01

    Full Text Available A small-sized photonic quantum random number generator, easy to be implemented in small electronic devices for secure data encryption and other applications, is highly demanding nowadays. Here, we propose a compact configuration with Silicon nanocrystals large area light emitting device (LED coupled to a Silicon photomultiplier to generate random numbers. The random number generation methodology is based on the photon arrival time and is robust against the non-idealities of the detector and the source of quantum entropy. The raw data show high quality of randomness and pass all the statistical tests in national institute of standards and technology tests (NIST suite without a post-processing algorithm. The highest bit rate is 0.5 Mbps with the efficiency of 4 bits per detected photon.

  3. Development of large-area silicon photomultiplier detectors for PET applications at FBK

    International Nuclear Information System (INIS)

    Zorzi, Nicola; Melchiorri, Mirko; Piazza, Alessandro; Piemonte, Claudio; Tarolli, Alessandro

    2011-01-01

    This paper reports on the development of large-area silicon photomultiplier (SiPM) detectors specifically designed for positron emission tomography (PET) instruments. The sensors under study are monolithic arrays of two different types: a 2x2 array of ∼4x4 mm 2 elements and an 8x8 array of 1.5x1.5 mm 2 pixels. These devices are characterized at wafer level by means of an automatic test procedure, consisting of current-voltage curves in forward and reverse bias. The tests allowed selection of functioning devices and evaluation of the uniformity of basic parameters. Results of the electrical characterization are reported showing that acceptable values of yield together with rather uniform distribution of parameters have been obtained. Reliability of produced SiPMs has been proved by long-term accelerated stress tests.

  4. Study of the photo-detection efficiency of FBK High-Density silicon photomultipliers

    International Nuclear Information System (INIS)

    Zappalà, G.; Regazzoni, V.; Acerbi, F.; Ferri, A.; Gola, A.; Paternoster, G.; Zorzi, N.; Piemonte, C.

    2016-01-01

    This work presents a study of the factors contributing to the Photo-Detection Efficiency of Silicon Photomultipliers (SiPMs): Quantum Efficiency, Triggering Probability and Fill Factor. Two different SiPM High-Density technologies are tested, NUV-HD, based on n-on-p junction, and RGB-HD, based on p-on-n junction, developed at FBK, Trento. The quantum efficiency was measured on photodiodes produced along with the SiPMs. The triggering probability, as a function of wavelength and bias voltage, was measured on circular Single Photon Avalanche Diodes (SPADs) with 100% fill factor. Square SPADs, having the same layout of single SiPM cells, were studied to measure the effective fill factor and compare it to the nominal value. The comparison of the circular and square SPADs allows to get the transition region size between the effective active area of the cell and the one defined by the layout.

  5. Time characteristics of detectors based on silicon photomultipliers for the GlueX experiment

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, F. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Somov, A. S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Somov, S. V. [National Research Nuclear Univ., Moscow (Russia); Tolstukhin, I. A. [National Research Nuclear Univ., Moscow (Russia); Indiana Univ., Bloomington, IN (United States)

    2017-06-16

    Here, silicon photomultipliers (SiPMs) are used in detectors of the GlueX experiment devoted to studying the nature of confinement. These detectors are operable at counting rates as high as 2 MHz with a time resolution (FWHM) of approximately 0.3 ns and a number of excited pixels of up to 104. For SiPMs that operate under these conditions, the measured dependences of the recovery time and the time resolution are presented as functions of the number of excited pixels and the excitation frequency. Using a picosecond laser, the time resolution has been measured for an array of 4 × 4 SiPMs, which was specially developed for the experiment.

  6. Gain monitoring of telescope array photomultiplier cameras for the first 4 years of operation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, B.K., E-mail: bkshin@hanyang.ac.kr [Hanyang University, Seongdong-gu, Seoul (Korea, Republic of); Tokuno, H.; Tsunesada, Y. [Tokyo Institute of Technology, Meguro, Tokyo (Japan); Abu-Zayyad, T. [University of Utah, High Energy Astrophysics Institute, Salt Lake City, UT (United States); Aida, R. [University of Yamanashi, Interdisciplinary Graduate School of Medicine and Engineering, Kofu, Yamanashi (Japan); Allen, M.; Anderson, R. [University of Utah, High Energy Astrophysics Institute, Salt Lake City, UT (United States); Azuma, R. [Tokyo Institute of Technology, Meguro, Tokyo (Japan); Barcikowski, E.; Belz, J.W.; Bergman, D.R.; Blake, S.A.; Cady, R. [University of Utah, High Energy Astrophysics Institute, Salt Lake City, UT (United States); Cheon, B.G., E-mail: bgcheon@hanyang.ac.kr [Hanyang University, Seongdong-gu, Seoul (Korea, Republic of); Chiba, J. [Tokyo University of Science, Noda, Chiba (Japan); Chikawa, M. [Kinki University, Higashi Osaka, Osaka (Japan); Cho, E.J. [Hanyang University, Seongdong-gu, Seoul (Korea, Republic of); Cho, W.R. [Yonsei University, Seodaemun-gu, Seoul (Korea, Republic of); Fujii, H. [Institute of Particle and Nuclear Studies, KEK, Tsukuba, Ibaraki (Japan); Fujii, T. [Osaka City University, Osaka, Osaka (Japan); and others

    2014-12-21

    The stability of the gain of the photomultiplier (PMT) camera for the Fluorescence Detector (FD) of the Telescope Array experiment was monitored using an {sup 241}Am loaded scintillator pulsers (YAP) and a diffused xenon flasher (TXF) for a selected set of 35 PMT-readout channels. From the monitoring of YAP pulses over four years of FD operation, we found slow monotonic drifts of PMT gains at a rate of −1.7∼+1.7%/year. An average of the PMT gains over the 35 channels stayed nearly constant with a rate of change measured at −0.01±0.31(stat)±0.21(sys)%/year. No systematic decrease of the PMT gain caused by the night sky background was observed. Monitoring by the TXF also tracked the PMT gain drift of the YAP at 0.88±0.14(stat)%/year.

  7. Study of timing performance of silicon photomultiplier and application for a Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, G.S.M., E-mail: gamal.ahmed@assoc.oeaw.ac.a [Stefan Meyer Institute, Austrian Academy of Sciences, Vienna (Austria); Al-Azhar University, Faculty of Science, Physics Department, Cairo (Egypt); Buehler, P.; Marton, J.; Suzuki, K. [Stefan Meyer Institute, Austrian Academy of Sciences, Vienna (Austria)

    2011-02-01

    Silicon photomultipliers are very versatile photo-detectors due to their high photon detection efficiency, fast response, single photon counting capability, high amplification, and their insensitivity to magnetic fields. At our institute we are studying the performance of these photo-detectors at various operating conditions. On the basis of the experience in the laboratory we built a prototype of a timing Cherenkov detector consisting of a quartz radiator with two 3x3 mm{sup 2} MPPCs S10362-33-100C from Hamamatsu Photonics as photo-detectors. The MPPC sensors were operated with Peltier cooling to minimize thermal noise and to avoid gain drifts. The test measurements at the DA {Phi} NE Beam-Test Facility (BTF) at the Laboratori Nazionali di Frascati (LNF) with pulsed 490 MeV electrons and the results on timing performance with Cherenkov photons are presented.

  8. Progress in CsI-wire chamber imaging photomultipliers and single electron counters

    International Nuclear Information System (INIS)

    Breskin, A.; Chechik, R.; Dagendorf, V.; Pansky, A.; Vartsky, D.

    1990-10-01

    Electrons photoproduced by UV-photons on a CsI photocathode, or deposited by ionizing particles and ultrasoft x- rays in low-pressure gas media, are efficiently detected in low pressure multistep avalanche electron multipliers. A solid photocathode avalanche chamber (SPAC) imaging photomultiplier was coupled to a Xe-filled gas scintillation detector. Its performance when exposed to 60 KeV x rays is presented. The stability of the CsI photocathode is discussed in detail. The latest experimental results from primary ionization cluster counting of charged particles and ultrasoft x-rays are presented. UV laser-induced ionization and Monte-Carlo simulations are used to study the processes involved. (author)

  9. The STiC ASIC. High precision timing with silicon photomultipliers

    International Nuclear Information System (INIS)

    Harion, Tobias

    2015-01-01

    In recent years, Silicon Photomultipliers are being increasingly used for Time of Flight measurements in particle detectors. To utilize the high intrinsic time resolution of these sensors in detector systems, the development of specialized, highly integrated readout electronics is required. In this thesis, a mixed-signal application specific integrated circuit, named STiC, has been developed, characterized and integrated in a detector system. STiC has been specifically designed for high precision timing measurements with SiPMs, and is in particular dedicated to the EndoTOFPET-US project, which aims to achieve a coincidence time resolution of 200 ps FWHM and an energy resolution of less than 20% in an endoscopic positron emission tomography system. The chip integrates 64 high precision readout channels for SiPMs together with a digital core logic to process, store and transfer the recorded events to a data acquisition system. The performance of the chip has been validated in coincidence measurements using detector modules consisting of 3.1 x 3.1 x 15 mm 3 LYSO crystals coupled to Silicon Photomultipliers from Hamamatsu. The measurements show an energy resolution of 15% FWHM for the detection of 511 keV photons. A coincidence time resolution of 213 ps FWHM has been measured, which is among the best resolution values achieved to date with this detector topology. STiC has been integrated in the EndoTOFPET-US detector system and has been chosen as the baseline design for the readout of SiPM sensors in the Mu3e experiment.

  10. Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

    Science.gov (United States)

    Moskal, P.; Rundel, O.; Alfs, D.; Bednarski, T.; Białas, P.; Czerwiński, E.; Gajos, A.; Giergiel, K.; Gorgol, M.; Jasińska, B.; Kamińska, D.; Kapłon, Ł.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krzemień, W.; Kubicz, E.; Niedźwiecki, Sz; Pałka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Słomski, A.; Silarski, M.; Strzelecki, A.; Wieczorek, A.; Wiślicki, W.; Witkowski, P.; Zieliński, M.; Zoń, N.

    2016-03-01

    Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the 2× 5 configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the 2× 5 matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of ≈ 0.170 ns for 15 cm axial field-of-view (AFOV) and ≈ 0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.

  11. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos >> NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  12. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia ... of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia ...

  13. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... NEI YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  14. Rejection index for pressure tubes

    International Nuclear Information System (INIS)

    Mitchell, A.B.; Meneley, D.

    1989-10-01

    The objective of the present study was to establish a set of criteria (or Rejection Index) which could be used to decide whether a zirconium-2 1/2 w/o niobium pressure tube in a CANDU reactor should be removed from service due to in-service degradation. A critique of key issues associated with establishing a realistic rejection index was prepared. Areas of uncertainty in available information were identified and recommendations for further analysis and laboratory testing made. A Rejection Index based on the following limits has been recommended: 1) Limits related to design intent and normal operation: any garter spring must remain within the tolerance band specified for its design location; the annulus gas system must normally be operated in a circulating mode with a procedure in place for purging to prevent accumulation of deuterium. It must remain sensitive to leaks into any part of the systems; and pressure tube dimensions and distortions must be limited to maintain the fuel channels within the original design intent; 2) Limits related to defect tolerance: adequate time margins between occurrence of a leaking crack and unstable failure must be demonstrated for all fuel channels; long lap-type flaws are unacceptable; crack-like defects of any size are unacceptable; and score marks, frat marks and other defects with contoured profiles must fall below certain depth, length and stress intensity limits; and 3) Limits related to property degradation: at operating temperature each pressure tube must be demonstrated to have a critical length in excess of a stipulated value; the maximum equivalent hydrogen level in any pressure tube should not exceed a limit which should be defined taking into account the known history of that tube; the maximum equivalent hydrogen level in any rolled joint should not exceed a limit which is presently recommended as 200 ppm equivalent hydrogen; and the maximum diametral creep strain should be limited to less than 5%

  15. Statistics of multi-tube detecting systems

    International Nuclear Information System (INIS)

    Grau Carles, P.; Grau Malonda, A.

    1994-01-01

    In this paper three new statistical theorems are demonstrated and applied. These theorems simplify very much the obtention of the formulae to compute the counting efficiency when the detection system is formed by several photomultipliers associated in coincidence and sume. These theorems are applied to several photomultiplier arrangements in order to show their potential and the application. way

  16. Statistics of multi-tube detecting systems

    International Nuclear Information System (INIS)

    Grau Carles, P.; Grau Malonda, A.

    1994-01-01

    In this paper three new statistical theorems are demonstrated and applied. These theorems simplify very much the obtention of the formulae to compute the counting efficiency when the detection system is formed by several photomultipliers associated in coincidence and sum. These theorems are applied to several photomultiplier arrangements in order to show their potential and the application way. (Author) 6 refs

  17. Ultrasonography for confirmation of gastric tube placement.

    Science.gov (United States)

    Tsujimoto, Hiraku; Tsujimoto, Yasushi; Nakata, Yukihiko; Akazawa, Mai; Kataoka, Yuki

    2017-04-17

    %) studies to have low risk of bias in the participant selection domain because they performed ultrasound after they confirmed correct position by other methods.Few data (43 participants) were available for misplacement detection (specificity) due to the low incidence of misplacement. We did not perform a meta-analysis because of considerable heterogeneity of the index test such as the difference of echo window, the combination of ultrasound with other confirmation methods (e.g. saline flush visualization by ultrasound) and ultrasound during the insertion of the tube. For all settings, sensitivity estimates for individual studies ranged from 0.50 to 1.00 and specificity estimates from 0.17 to 1.00. For settings where X-ray was not readily available and participants underwent gastric tube insertion for drainage (four studies, 305 participants), sensitivity estimates of ultrasound in combination with other confirmatory tests ranged from 0.86 to 0.98 and specificity estimates of 1.00 with wide confidence intervals.For the studies using ultrasound alone (four studies, 314 participants), sensitivity estimates ranged from 0.91 to 0.98 and specificity estimates from 0.67 to 1.00. Of 10 studies that assessed the diagnostic accuracy of gastric tube placement, few studies had a low risk of bias. Based on limited evidence, ultrasound does not have sufficient accuracy as a single test to confirm gastric tube placement. However, in settings where X-ray is not readily available, ultrasound may be useful to detect misplaced gastric tubes. Larger studies are needed to determine the possibility of adverse events when ultrasound is used to confirm tube placement.

  18. Lunar Lava Tube Sensing

    Science.gov (United States)

    York, Cheryl Lynn; Walden, Bryce; Billings, Thomas L.; Reeder, P. Douglas

    1992-01-01

    Large (greater than 300 m diameter) lava tube caverns appear to exist on the Moon and could provide substantial safety and cost benefits for lunar bases. Over 40 m of basalt and regolith constitute the lava tube roof and would protect both construction and operations. Constant temperatures of -20 C reduce thermal stress on structures and machines. Base designs need not incorporate heavy shielding, so lightweight materials can be used and construction can be expedited. Identification and characterization of lava tube caverns can be incorporated into current precursor lunar mission plans. Some searches can even be done from Earth. Specific recommendations for lunar lava tube search and exploration are (1) an Earth-based radar interferometer, (2) an Earth-penetrating radar (EPR) orbiter, (3) kinetic penetrators for lunar lava tube confirmation, (4) a 'Moon Bat' hovering rocket vehicle, and (5) the use of other proposed landers and orbiters to help find lunar lava tubes.

  19. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1983-08-01

    A review of the performance of steam generator tubes in 110 water-cooled nuclear power reactors showed that tubes were plugged at 46 (42 percent) of the reactors. The number of tubes removed from service increased from 1900 (0.14 percent) in 1980 to 4692 (0.30 percent) in 1981. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that used all-volatile treatment since start-up. At one reactor a large number of degraded tubes were repaired by sleeving which is expected to become an important method of tube repair in the future

  20. Manual tube welding torch

    International Nuclear Information System (INIS)

    Kiefer, J.H.; Smith, D.J.

    1981-01-01

    In a welding torch which fits over a tube intermediate the ends thereof for welding the juncture between the tube and a boss on the back side of a tube plate, a split housing encloses a tungsten electrode, a filler wire duct and a fiber optic bundle arranged to observe the welding process. A shielding gas duct is provided in the housing. A screw is provided for setting electrode/work distance. Difficult remote tube welding operations can be performed with the apparatus. (author)

  1. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1984-10-01

    A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization

  2. Wound tube heat exchanger

    Science.gov (United States)

    Ecker, Amir L.

    1983-01-01

    What is disclosed is a wound tube heat exchanger in which a plurality of tubes having flattened areas are held contiguous adjacent flattened areas of tubes by a plurality of windings to give a double walled heat exchanger. The plurality of windings serve as a plurality of effective force vectors holding the conduits contiguous heat conducting walls of another conduit and result in highly efficient heat transfer. The resulting heat exchange bundle is economical and can be coiled into the desired shape. Also disclosed are specific embodiments such as the one in which the tubes are expanded against their windings after being coiled to insure highly efficient heat transfer.

  3. Sapphire tube pressure vessel

    Science.gov (United States)

    Outwater, John O.

    2000-01-01

    A pressure vessel is provided for observing corrosive fluids at high temperatures and pressures. A transparent Teflon bag contains the corrosive fluid and provides an inert barrier. The Teflon bag is placed within a sapphire tube, which forms a pressure boundary. The tube is received within a pipe including a viewing window. The combination of the Teflon bag, sapphire tube and pipe provides a strong and inert pressure vessel. In an alternative embodiment, tie rods connect together compression fittings at opposite ends of the sapphire tube.

  4. Fuel nozzle tube retention

    Energy Technology Data Exchange (ETDEWEB)

    Cihlar, David William; Melton, Patrick Benedict

    2017-02-28

    A system for retaining a fuel nozzle premix tube includes a retention plate and a premix tube which extends downstream from an outlet of a premix passage defined along an aft side of a fuel plenum body. The premix tube includes an inlet end and a spring support feature which is disposed proximate to the inlet end. The premix tube extends through the retention plate. The spring retention feature is disposed between an aft side of the fuel plenum and the retention plate. The system further includes a spring which extends between the spring retention feature and the retention plate.

  5. Steam generator tube failures

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

  6. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  7. Eddy current inspection of tubing

    International Nuclear Information System (INIS)

    Bauza, J. L. R.; Herrero, J.; Diaz, J.

    1966-01-01

    The Experimental research work carried out to develop a Eddy current testing equipment is described. Search coils with ferrite or air cores were used and the obtained results are discussed. Valuable information was gained from a improved channel in which a direct measure of the defect and the reference signal phase difference is obtained. Artificial defect used to evaluate resolution and sensitivity were produced by electro-machining and mechanical means. Finned SAP tubing was tested in a routine basis with the described equipment and the results plotted. Basic and theoretical considerations on the Eddy current testing technique are given in the last section of this report. (Author)

  8. Chest Tube Thoracostomy

    Science.gov (United States)

    ... in the space around the lungs (called a pleural effusion) . A chest tube may also be needed when a patient has ... or chest CT are also done to evaluate pleural fluid. If the X-ray shows a need for a chest tube to drain fluid or air, the procedure is ...

  9. Resolution of heterogeneous fluorescence emission signals and decay lifetime measurement on fluorochrome-labeled cells by phase-sensitive FCM

    Energy Technology Data Exchange (ETDEWEB)

    Steinkamp, J.A.; Crissman, H.A.

    1993-01-01

    A phase-sensitive flow cytometer has been developed to resolve signals from heterogeneous fluorescence emission spectra and quantify fluorescence decay times on cells labeled with fluorescent dyes. This instrument combines flow cytometry (FCM) and fluorescence spectroscopy measurement principles to provide unique capabilities for making phase-resolved measurements on single cells in flow, while preserving conventional FCM measurement capabilities. Stained cells are analyzed as they pass through an intensity-modulated (sinusoid) laser excitation beam. Fluorescence is measured orthogonally using a s barrier filter to block scattered laser excitation light, and a photomultiplier tube detector output signals, which are shifted in phase from a reference signal and amplitude demodulated, are processed by phase-sensitive detection electronics to resolve signals from heterogeneous emissions and quantify decay lifetimes directly. The output signals are displayed as frequency distribution histograms and bivariate diagrams using a computer-based data acquisition system. Results have demonstrated signal phase shift, amplitude demodulation, and average measurement of fluorescence lifetimes on stained cells; a detection limit threshold of 300 to 500 fluorescein isothiocyanate (FITC); fluorescence measurement precision of 1.3% on alignment fluorospheres and 3.4% on propidium iodide (PI)-stained cells; the resolution of PI and FITC signals from cells stainedin combination with PI and FITC, based on differences in their decay lifetimes; and the ability to measure single decay nines by the two-phase, phase comparator, method.

  10. Resolution of heterogeneous fluorescence emission signals and decay lifetime measurement on fluorochrome-labeled cells by phase-sensitive FCM

    Energy Technology Data Exchange (ETDEWEB)

    Steinkamp, J.A.; Crissman, H.A.

    1993-02-01

    A phase-sensitive flow cytometer has been developed to resolve signals from heterogeneous fluorescence emission spectra and quantify fluorescence decay times on cells labeled with fluorescent dyes. This instrument combines flow cytometry (FCM) and fluorescence spectroscopy measurement principles to provide unique capabilities for making phase-resolved measurements on single cells in flow, while preserving conventional FCM measurement capabilities. Stained cells are analyzed as they pass through an intensity-modulated (sinusoid) laser excitation beam. Fluorescence is measured orthogonally using a s barrier filter to block scattered laser excitation light, and a photomultiplier tube detector output signals, which are shifted in phase from a reference signal and amplitude demodulated, are processed by phase-sensitive detection electronics to resolve signals from heterogeneous emissions and quantify decay lifetimes directly. The output signals are displayed as frequency distribution histograms and bivariate diagrams using a computer-based data acquisition system. Results have demonstrated signal phase shift, amplitude demodulation, and average measurement of fluorescence lifetimes on stained cells; a detection limit threshold of 300 to 500 fluorescein isothiocyanate (FITC); fluorescence measurement precision of 1.3% on alignment fluorospheres and 3.4% on propidium iodide (PI)-stained cells; the resolution of PI and FITC signals from cells stainedin combination with PI and FITC, based on differences in their decay lifetimes; and the ability to measure single decay nines by the two-phase, phase comparator, method.

  11. Ventricular tachycardia following tube thoracotomy.

    Science.gov (United States)

    Hibbert, Benjamin; Lim, Toon Wei; Hibbert, Rebecca; Green, Martin; Gollob, Michael H; Davis, Darryl R

    2010-10-01

    Arrhythmias provoked by tube thoracotomy are a rare complication. We report a ventricular tachycardia after chest tube insertion for a device-related pneumothorax. Sinus rhythm was restored only by removal of the chest tube and insertion of a pliable pleural drain. Identification of the chest tube as an arrhythmic trigger following tube thoracotomy is essential in definitive management of refractory arrhythmias.

  12. Molybdenum Tube Characterization report

    Energy Technology Data Exchange (ETDEWEB)

    Beaux II, Miles Frank [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Usov, Igor Olegovich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-07

    Chemical vapor deposition (CVD) techniques have been utilized to produce free-standing molybdenum tubes with the end goal of nuclear fuel clad applications. In order to produce tubes with properties desirable for this application, deposition rates were lowered requiring long deposition durations on the order of 50 hours. Standard CVD methods as well as fluidized-bed CVD (FBCVD) methods were applied towards these objectives. Characterization of the tubes produced in this manner revealed material suitable for fuel clad applications, but lacking necessary uniformity across the length of the tubes. The production of freestanding Mo tubes that possess the desired properties across their entire length represents an engineering challenge that can be overcome in a next iteration of the deposition system.

  13. Categorising YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s...... technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition...... and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within...

  14. Design of a portable fluoroquinolone analyzer based on terbium-sensitized luminescence

    Science.gov (United States)

    Chen, Guoying

    2007-09-01

    A portable fluoroquinolone (FQ) analyzer is designed and prototyped based on terbium-sensitized luminescence (TSL). The excitation source is a 327-nm light emitting diode (LED) operated in pulsed mode; and the luminescence signal is detected by a photomultiplier tube (PMT). In comparison to a conventional xenon flashlamp, an LED is small, light, robust, and energy efficient. More importantly, its narrow emission bandwidth and low residual radiation reduce background signal. In pulse mode, an LED operates at a current 1-2 orders of magnitude lower than that of a xenon flashlamp, thus minimizing electromagnetic interference (EMI) to the detector circuitry. The PMT is gated to minimize its response to the light source. These measures lead to reduced background noise in time domain. To overcome pulse-to-pulse variation signal normalization is implemented based on individual pulse energy. Instrument operation and data processing are controlled by a computer running a custom LabVIEW program. Enrofloxacin (ENRO) is used as a model analyte to evaluate instrument performance. The integrated TSL intensity reveals a linear dependence up to 2 ppm. A 1.1-ppb limit of detection (LOD) is achieved with relative standard deviation (RSD) averaged at 5.1%. The background noise corresponds to ~5 ppb. At 19 lbs, this portable analyzer is field deployable for agriculture, environmental and clinical analyses.

  15. Scalable gamma-ray camera for wide-area search based on silicon photomultipliers array

    Science.gov (United States)

    Jeong, Manhee; Van, Benjamin; Wells, Byron T.; D'Aries, Lawrence J.; Hammig, Mark D.

    2018-03-01

    Portable coded-aperture imaging systems based on scintillators and semiconductors have found use in a variety of radiological applications. For stand-off detection of weakly emitting materials, large volume detectors can facilitate the rapid localization of emitting materials. We describe a scalable coded-aperture imaging system based on 5.02 × 5.02 cm2 CsI(Tl) scintillator modules, each partitioned into 4 × 4 × 20 mm3 pixels that are optically coupled to 12 × 12 pixel silicon photo-multiplier (SiPM) arrays. The 144 pixels per module are read-out with a resistor-based charge-division circuit that reduces the readout outputs from 144 to four signals per module, from which the interaction position and total deposited energy can be extracted. All 144 CsI(Tl) pixels are readily distinguishable with an average energy resolution, at 662 keV, of 13.7% FWHM, a peak-to-valley ratio of 8.2, and a peak-to-Compton ratio of 2.9. The detector module is composed of a SiPM array coupled with a 2 cm thick scintillator and modified uniformly redundant array mask. For the image reconstruction, cross correlation and maximum likelihood expectation maximization methods are used. The system shows a field of view of 45° and an angular resolution of 4.7° FWHM.

  16. A design of a valid signal selecting and position decoding ASIC for PET using silicon photomultipliers

    Science.gov (United States)

    Cho, M.; Lim, K.-t.; Kim, H.; Yeom, J.-y.; Kim, J.; Lee, C.; Choi, H.; Cho, G.

    2017-01-01

    In most cases, a PET system has numerous electrical components and channel circuits and thus it would rather be a bulky product. Also, most existing systems receive analog signals from detectors which make them vulnerable to signal distortions. For these reasons, channel reduction techniques are important. In this work, an ASIC for PET module is being proposed. An ASIC chip for 16 PET detector channels, VSSPDC, has been designed and simulated. The main function of the chip is 16-to-1 channel reduction, i.e., finding the position of only the valid signals, signal timing, and magnitudes in all 16 channels at every recorded event. The ASIC comprises four of 4-channel modules and a 2nd 4-to-1 router. A single channel module comprises a transimpedance amplifier for the silicon photomultipliers, dual comparators with high and low level references, and a logic circuitry. While the high level reference was used to test the validity of the signal, the low level reference was used for the timing. The 1-channel module of the ASIC produced an energy pulse by time-over-threshold method and it also produced a time pulse with a fixed delayed time. Since the ASIC chip outputs only a few digital pulses and does not require an external clock, it has an advantage over noise properties. The cadence simulation showed the good performance of the chip as designed.

  17. An innovative silicon photomultiplier digitizing camera for gamma-ray astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Heller, M. [DPNC-Universite de Geneve, Geneva (Switzerland); Schioppa, E. Jr; Porcelli, A.; Pujadas, I.T.; Della Volpe, D.; Montaruli, T.; Cadoux, F.; Favre, Y.; Christov, A.; Rameez, M.; Miranda, L.D.M. [DPNC-Universite de Geneve, Geneva (Switzerland); Zietara, K.; Idzkowski, B.; Jamrozy, M.; Ostrowski, M.; Stawarz, L.; Zagdanski, A. [Jagellonian University, Astronomical Observatory, Krakow (Poland); Aguilar, J.A. [DPNC-Universite de Geneve, Geneva (Switzerland); Universite Libre Bruxelles, Faculte des Sciences, Brussels (Belgium); Prandini, E.; Lyard, E.; Neronov, A.; Walter, R. [Universite de Geneve, Department of Astronomy, Geneva (Switzerland); Rajda, P.; Bilnik, W.; Kasperek, J.; Lalik, K.; Wiecek, M. [AGH University of Science and Technology, Krakow (Poland); Blocki, J.; Mach, E.; Michalowski, J.; Niemiec, J.; Skowron, K.; Stodulski, M. [Instytut Fizyki Jadrowej im. H. Niewodniczanskiego Polskiej Akademii Nauk, Krakow (Poland); Bogacz, L. [Jagiellonian University, Department of Information Technologies, Krakow (Poland); Borkowski, J.; Frankowski, A.; Janiak, M.; Moderski, R. [Polish Academy of Science, Nicolaus Copernicus Astronomical Center, Warsaw (Poland); Bulik, T.; Grudzinska, M. [University of Warsaw, Astronomical Observatory, Warsaw (Poland); Mandat, D.; Pech, M.; Schovanek, P. [Institute of Physics of the Czech Academy of Sciences, Prague (Czech Republic); Marszalek, A.; Stodulska, M. [Instytut Fizyki Jadrowej im. H. Niewodniczanskiego Polskiej Akademii Nauk, Krakow (Poland); Jagellonian University, Astronomical Observatory, Krakow (Poland); Pasko, P.; Seweryn, K. [Centrum Badan Kosmicznych Polskiej Akademii Nauk, Warsaw (Poland); Sliusar, V. [Universite de Geneve, Department of Astronomy, Geneva (Switzerland); Taras Shevchenko National University of Kyiv, Astronomical Observatory, Kyiv (Ukraine)

    2017-01-15

    The single-mirror small-size telescope (SST-1M) is one of the three proposed designs for the small-size telescopes (SSTs) of the Cherenkov Telescope Array (CTA) project. The SST-1M will be equipped with a 4 m-diameter segmented reflector dish and an innovative fully digital camera based on silicon photo-multipliers. Since the SST sub-array will consist of up to 70 telescopes, the challenge is not only to build telescopes with excellent performance, but also to design them so that their components can be commissioned, assembled and tested by industry. In this paper we review the basic steps that led to the design concepts for the SST-1M camera and the ongoing realization of the first prototype, with focus on the innovative solutions adopted for the photodetector plane and the readout and trigger parts of the camera. In addition, we report on results of laboratory measurements on real scale elements that validate the camera design and show that it is capable of matching the CTA requirements of operating up to high moonlight background conditions. (orig.)

  18. Immersion cooling of silicon photomultipliers (SiPM) for nuclear medicine imaging applications

    International Nuclear Information System (INIS)

    Raylman, R.R.; Stolin, A.V.

    2016-01-01

    Silicon photomultipliers (SiPM) are compact, high amplification light detection devices that have recently been incorporated into magnetic field-compatible positron emission tomography (PET) scanners. To take full advantage of these devices, it is preferable to cool them below room temperature. Most current methods are limited to the cooling of individual detector modules, increasing complexity and cost of scanners made-up of a large number of modules. In this work we investigated a new method of cooling, immersion of the detector modules in non-electrically conductive, cooled liquid. A small-scale prototype system was constructed to cool a relatively large area SiPM-based, scintillator detector module by immersing it in a circulating bath of mineral oil. Testing demonstrated that the system rapidly decreased and stabilized the temperature of the device. Operation of the detector illustrated the expected benefits of cooling, with no apparent degradation of performance attributable to immersion in fluid. - Highlights: • Immersion cooling is new, simple and inexpensive method to cool solid state based nuclear medicine scanner. • Method successfully tested on a scaled version of an SiPM-based PET detector module. • Can be scaled up to cool a complete PET scanner.

  19. Silicon photomultipliers as readout elements for a Compton effect polarimeter: the COMPASS project

    CERN Document Server

    Del Monte, E; Brandonisio, A; Muleri, F; Soffitta, P; Costa, E; di Persio, G; Cosimo, S Di; Massaro, E; Morbidini, A; Morelli, E; Pacciani, L; Fabiani, S; Michilli, D; Giarrusso, S; Catalano, O; Impiombato, D; Mineo, T; Sottile, G; Billotta, S

    2016-01-01

    COMpton Polarimeter with Avalanche Silicon readout (COMPASS) is a research and development project that aims to measure the polarization of X-ray photons through Compton Scattering. The measurement is obtained by using a set of small rods of fast scintillation materials with both low-Z (as active scatterer) and high-Z (as absorber), all read-out with Silicon Photomultipliers. By this method we can operate scattering and absorbing elements in coincidence, in order to reduce the background. In the laboratory we are characterising the SiPMs using different types of scintillators and we are optimising the performances in terms of energy resolution, energy threshold and photon tagging efficiency. We aim to study the design of two types of satellite-borne instruments: a focal plane polarimeter to be coupled with multilayer optics for hard X-rays and a large area and wide field of view polarimeter for transients and Gamma Ray Bursts. In this paper we describe the status of the COMPASS project, we report about the la...

  20. Performance study of Philips digital silicon photomultiplier coupled to scintillating crystals

    CERN Document Server

    Liu, Z.; Auffray, E.; Lecoq, P.; Paganoni, M.

    2016-01-01

    Silicon photomultipliers (SiPMs) and scintillators are often arranged in the shape of arrays in Positron Emission Tomography (PET) systems. Digital SiPMs provide signal readout in single photon avalanche diode (SPAD) level. From the photon count rate measurement of each SPAD cell of digital SiPM, we found that the output scintillating photons distribute in an area larger than the scintillator physical coupling area. Taking advantage of the possibility to enable/disable individual cells of the digital SiPM, a group of Lutetium-yttrium oxyorthosilicate (LYSO) crystals with different dimensions coupled to a digital SiPM was used to study the influence of using different SiPM active area on the number of photons detected, energy resolution and coincidence time resolution (CTR). For the same crystal coupled to the digital SiPM, the larger the active area of digital SiPM, the higher the number of photons detected. The larger active area of the digital SiPM also results in a better energy resolution after saturation...

  1. A design of a valid signal selecting and position decoding ASIC for PET using silicon photomultipliers

    International Nuclear Information System (INIS)

    Cho, M.; Lim, K.-T.; Kim, J.; Lee, C.; Cho, G.; Kim, H.; Yeom, J.-Y.; Choi, H.

    2017-01-01

    In most cases, a PET system has numerous electrical components and channel circuits and thus it would rather be a bulky product. Also, most existing systems receive analog signals from detectors which make them vulnerable to signal distortions. For these reasons, channel reduction techniques are important. In this work, an ASIC for PET module is being proposed. An ASIC chip for 16 PET detector channels, VSSPDC, has been designed and simulated. The main function of the chip is 16-to-1 channel reduction, i.e., finding the position of only the valid signals, signal timing, and magnitudes in all 16 channels at every recorded event. The ASIC comprises four of 4-channel modules and a 2 nd 4-to-1 router. A single channel module comprises a transimpedance amplifier for the silicon photomultipliers, dual comparators with high and low level references, and a logic circuitry. While the high level reference was used to test the validity of the signal, the low level reference was used for the timing. The 1-channel module of the ASIC produced an energy pulse by time-over-threshold method and it also produced a time pulse with a fixed delayed time. Since the ASIC chip outputs only a few digital pulses and does not require an external clock, it has an advantage over noise properties. The cadence simulation showed the good performance of the chip as designed.

  2. Characterization of scintillating plastic fibers and silicon photomultipliers for their usage in a particle telescope

    Energy Technology Data Exchange (ETDEWEB)

    Pruefer, Lea; Losekamm, Martin; Poeschl, Thomas; Greenwald, Daniel; Paul, Stephan [Technische Universitaet Muenchen, 85748 Garching (Germany)

    2016-07-01

    The Multi-purpose Active-target Particle Telescope (MAPT) is a newly developed compact charged-particle detector. It can be used for space applications, such as radiation monitoring on spacecraft or for stratospheric research balloons. Its core consists of scintillating plastic fibers coupled to silicon photomultiplier (SiPMs). The energy reconstruction of the incoming particles is based on an extended Bragg curve spectroscopy technique, requiring a good measurement of the energy deposition. Therefore, non-linearities of the measured light output -such as quenching effects of the scintillating material or saturation of the SiPMs at high light yields- have to be known quantitatively. To investigate these effects, two scaled-down prototypes were built, consisting of 128 and 16 channels. The first one was tested at a stationary proton beam at Paul Scherrer Institute. We determine Birk's coefficient describing the ionization quenching of the scintillator and calculate the characteristic photon detection efficiency of the SiPMs. We explain the results of the first prototype tests and the characterization of the SiPMs.

  3. A Compact Cosmic Ray Telescope using Silicon Photomultipliers for use in High Schools

    Science.gov (United States)

    Castro, Luis; Elizondo, Leonardo; Shelor, Mark; Cervantes, Omar; Fan, Sewan; Ritt, Stefan

    2016-03-01

    Over the years, the QuarkNet and the LBL Cosmic Ray Project have helped trained thousands of high school students and teachers to explore cosmic ray physics. To get high school students in the Salinas, CA area also excited about cosmic rays, we constructed a cosmic ray telescope as a physics outreach apparatus. Our apparatus includes a pair of plastic scintillators coupled to silicon photomultipliers (SiPM) and a coincidence circuit board. We designed and constructed custom circuit boards for mounting the SiPM detectors, the high voltage power supplies and coincidence AND circuit. The AND logic signals can be used for triggering data acquisition devices including an oscilloscope, a waveform digitizer or an Arduino microcontroller. To properly route the circuit wire traces, the circuit boards were layout in Eagle and fabricated in-house using a circuit board maker from LPKF LASER, model Protomat E33. We used a Raspberry Pi computer to control a fast waveform sampler, the DRS4 to digitize the SiPM signal waveforms. The CERN PAW software package was used to analyze the amplitude and time distributions of SiPM detector signals. At this conference, we present our SiPM experimental setup, circuit board fabrication procedures and the data analysis work flow. AIP Megger's Award, Dept. of Ed. Title V Grant PO31S090007.

  4. Development and featuring of hemispherical photomultipliers for cosmic ray detection - calibration of surface detectors and analysis of horizontal showers at the Pierre Auger Observatory

    International Nuclear Information System (INIS)

    Dornic, D.

    2006-09-01

    The large photomultipliers (PMT) are currently used in astro-particle and neutrino experiments where they have to detect low levels of light. We have studied and characterised large PMTs developed by the PHOTONIS Group Company. The first part of this thesis is dedicated to the full characterization of two types of multipliers currently used in large PMTs. Then, we present results of a new photocathode process, applied on the XPI805 (PMT used in the Pierre Auger Observatory) in order to improve the quantum efficiency. Finally, we study the PMT diameter influence on main parameters (5, 8 and 10 inches). The second part is devoted to the study of the water Cerenkov tank (WCD) response to the shower particles and the horizontal air showers analysis with the Pierre Auger Observatory. The main parameters of a WCD simulation developed in the Auger IPN group were calibrated with several measurements on vertical and inclined muons, performed on dedicated test tanks. The kind of detector used in the surface detector allows detecting very inclined events with a good sensitivity (zenith angle superior to 70 degrees). We have established specific methods to analyze these events (selection and reconstruction). These methods were applied to the Auger data in order to obtain the energy spectrum of the horizontal events. Finally, we detailed two methods to test directly the hadronic models predictions by studying the air showers muonic component. (author)

  5. Isolated Fallopian Tube Torsion

    Directory of Open Access Journals (Sweden)

    S. Kardakis

    2013-01-01

    Full Text Available Isolated torsion of the Fallopian tube is a rare gynecological cause of acute lower abdominal pain, and diagnosis is difficult. There are no pathognomonic symptoms; clinical, imaging, or laboratory findings. A preoperative ultrasound showing tubular adnexal masses of heterogeneous echogenicity with cystic component is often present. Diagnosis can rarely be made before operation, and laparoscopy is necessary to establish the diagnosis. Unfortunately, surgery often is performed too late for tube conservation. Isolated Fallopian tube torsion should be suspected in case of acute pelvic pain, and prompt intervention is necessary.

  6. Automation in tube finishing bay

    International Nuclear Information System (INIS)

    Bhatnagar, Prateek; Satyadev, B.; Raghuraman, S.; Syama Sundara Rao, B.

    1997-01-01

    Automation concept in tube finishing bay, introduced after the final pass annealing of PHWR tubes resulted in integration of number of sub-systems in synchronisation with each other to produce final cut fuel tubes of specified length, tube finish etc. The tube finishing bay which was physically segregated into four distinct areas: 1. tube spreader and stacking area, 2. I.D. sand blasting area, 3. end conditioning, wad blowing, end capping and O.D. wet grinding area, 4. tube inspection, tube cutting and stacking area has been studied

  7. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  8. Tube Alinement for Machining

    Science.gov (United States)

    Garcia, J.

    1984-01-01

    Tool with stepped shoulders alines tubes for machining in preparation for welding. Alinement with machine tool axis accurate to within 5 mils (0.13mm) and completed much faster than visual setup by machinist.

  9. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1982-04-01

    The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1980. Tube defects occurred at 38% of the 97 reactors surveyed. This is a marginal improvement over 1979 when defects occurred at 41% of the reactors. The number of failed tubes was also lower, 0.14% of the tubes in service in 1980 compared with 0.20% of those in service in 1979. Analysis of the causes of these failures indicates that stress corrosion cracking was the leading failure mechanism. Reactors that used all-volatile treatment of secondary water, with or without full-flow condensate demineralization since start-up showed the lowest incidence of corrosion-related defects

  10. Ear tube insertion

    Science.gov (United States)

    ... mastoiditis) or the brain, or that damages nearby nerves Injury to the ear after sudden changes in ... does not heal after the tube falls out. Most of the time, these problems DO NOT last long. They also ...

  11. Tube Feeding Troubleshooting Guide

    Science.gov (United States)

    ... the diameter is measured in units known as French sizes, or “Fr”; a low profile tube also ... your quality of life. You are encouraged to speak with your physician, dietitian, home care company, or ...

  12. Magnesium tube hydroforming

    Energy Technology Data Exchange (ETDEWEB)

    Liewald, M.; Pop, R. [Institute for Metal Forming Technology (IFU), Stuttgart (Germany)

    2008-04-15

    Magnesium alloys reveal a good strength-to-weight ratio in the family of lightweight metals and gains potential to provide up to 30% mass savings compared to aluminium and up to 75 % compared to steel. The use of sheet magnesium alloys for auto body applications is however limited due to the relatively low formability at room temperature. Within the scope of this paper, extruded magnesium tubes, which are suitable for hydroforming applications, have been investigated. Results obtained at room temperature using magnesium AZ31 tubes show that circumferential strains are limited to a maximal value of 4%. In order to examine the influence of the forming temperature on tube formability, investigations have been carried out with a new die set for hot internal high pressure (IHP) forming at temperatures up to 400 C. Earlier investigations with magnesium AZ31 tubes have shown that fractures occur along the welding line at tubes extruded over a spider die, whereby a non-uniform expansion at bursting with an elongation value of 24% can be observed. A maximum circumferential strain of approx. 60% could be attained when seamless, mechanically pre-expanded and annealed tubes of the same alloy have been used. The effect of annealing time on materials forming properties shows a fine grained structure for sufficient annealing times as well as deterioration with a large increase at same time. Hence, seamless ZM21 tubes have been used in the current investigations. With these tubes, an increased tensile fracture strain of 116% at 350 C is observed as against 19% at 20 C, obtained by tensile testing of milled specimens from the extruded tubes. This behaviour is also seen under the condition of tool contact during the IHP forming process. To determine the maximum circumferential strain at different forming temperatures and strain rates, the tubes are initially bulged in a die with square cross-section under plane stress conditions. Thereafter, the tubes are calibrated by using an

  13. Power vacuum tubes handbook

    CERN Document Server

    Whitaker, Jerry

    2012-01-01

    Providing examples of applications, Power Vacuum Tubes Handbook, Third Edition examines the underlying technology of each type of power vacuum tube device in common use today. The author presents basic principles, reports on new development efforts, and discusses implementation and maintenance considerations. Supporting mathematical equations and extensive technical illustrations and schematic diagrams help readers understand the material. Translate Principles into Specific Applications This one-stop reference is a hands-on guide for engineering personnel involved in the design, specification,

  14. Low-cost, compact, cooled photomultiplier assembly for use in magnetic fields up to 1400 Gauss

    Science.gov (United States)

    Patch, R. W.; Tashjian, R. A.; Jentner, T. A.

    1975-01-01

    Use of vortex tube for cooling and concentric shielding have produced smaller and more compact unit than was previously available. Future uses of device could include installation in gas chromatographs and mass spectrometers. Additional uses would include measurements and controls in magnetohydrodynamic power generators and fusion reactors.

  15. Pulse Shape Analysis and Discrimination for Silicon-Photomultipliers in Helium-4 Gas Scintillation Neutron Detector

    Science.gov (United States)

    Barker, Cathleen; Zhu, Ting; Rolison, Lucas; Kiff, Scott; Jordan, Kelly; Enqvist, Andreas

    2018-01-01

    Using natural helium (helium-4), the Arktis 180-bar pressurized gas scintillator is capable of detecting and distinguishing fast neutrons and gammas. The detector has a unique design of three optically separated segments in which 12 silicon-photomultiplier (SiPM) pairs are positioned equilaterally across the detector to allow for them to be fully immersed in the helium-4 gas volume; consequently, no additional optical interfaces are necessary. The SiPM signals were amplified, shaped, and readout by an analog board; a 250 MHz, 14-bit digitizer was used to examine the output pulses from each SiPMpair channel. The SiPM over-voltage had to be adjusted in order to reduce pulse clipping and negative overshoot, which was observed for events with high scintillation production. Pulse shaped discrimination (PSD) was conducted by evaluating three different parameters: time over threshold (TOT), pulse amplitude, and pulse integral. In order to differentiate high and low energy events, a 30ns gate window was implemented to group pulses from two SiPM channels or more for the calculation of TOT. It was demonstrated that pulses from a single SiPM channel within the 30ns window corresponded to low-energy gamma events while groups of pulses from two-channels or more were most likely neutron events. Due to gamma pulses having lower pulse amplitude, the percentage of measured gamma also depends on the threshold value in TOT calculations. Similarly, the threshold values were varied for the optimal PSD methods of using pulse amplitude and pulse area parameters. Helium-4 detectors equipped with SiPMs are excellent for in-the-field radiation measurement of nuclear spent fuel casks. With optimized PSD methods, the goal of developing a fuel cask content monitoring and inspection system based on these helium-4 detectors will be achieved.

  16. Gastrostomy feeding tube - pump - child

    Science.gov (United States)

    ... tube feeding; PEG tube care; Feeding - gastrostomy tube - pump; G-tube - pump; Gastrostomy button - pump; Bard Button - pump; MIC-KEY - pump ... Gather supplies: Feeding pump (electronic or battery powered) Feeding ... pump (includes a feeding bag, drip chamber, roller clamp, ...

  17. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  18. Categorising YouTube

    Directory of Open Access Journals (Sweden)

    Thomas Mosebo Simonsen

    2011-09-01

    Full Text Available This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC of YouTube. The article investigates the construction of navigationprocesses on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within the interacting relationship of new and old genres are discussed. It is argued that the utility of a conventional categorical system is primarily of analytical and theoretical interest rather than as a practical instrument.

  19. Enriched Boron-Doped Amorphous Selenium Based Position-Sensitive Solid-State Thermal Neutron Detector for MPACT Applications

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Krishna [Univ. of South Carolina, Columbia, SC (United States)

    2017-09-29

    High-efficiency thermal neutron detectors with compact size, low power-rating and high spatial, temporal and energy resolution are essential to execute non-proliferation and safeguard protocols. The demands of such detector are not fully covered by the current detection system such as gas proportional counters or scintillator-photomultiplier tube combinations, which are limited by their detection efficiency, stability of response, speed of operation, and physical size. Furthermore, world-wide shortage of 3He gas, required for widely used gas detection method, has further prompted to design an alternative system. Therefore, a solid-state neutron detection system without the requirement of 3He will be very desirable. To address the above technology gap, we had proposed to develop new room temperature solidstate thermal neutron detectors based on enriched boron (10B) and enriched lithium (6Li) doped amorphous Se (As- 0.52%, Cl 5 ppm) semiconductor for MPACT applications. The proposed alloy materials have been identified for its many favorable characteristics - a wide bandgap (~2.2 eV at 300 K) for room temperature operation, high glass transition temperature (tg ~ 85°C), a high thermal neutron cross-section (for boron ~ 3840 barns, for lithium ~ 940 barns, 1 barn = 10-24 cm2), low effective atomic number of Se for small gamma ray sensitivity, and high radiation tolerance due to its amorphous structure.

  20. Simulations of the breakdown characteristics of n-on-p backside-illumination Silicon Photomultipliers by TCAD

    Science.gov (United States)

    He, Ran; Yan, Guangqing; Liu, Jian; Cheng, Wenxuan; Liu, Rongdan; Liang, Kun; Yang, Ru; Han, Dejun

    2018-03-01

    This paper investigates, using Synopsys Sentaurus TCAD simulation, the dependence of the breakdown voltage of n-on-p backside-illumination Silicon Photomultipliers (BSI-SiPM) on the implantation dose, the implantation energy and the screening SiO2 thickness for implantation in p-enrichment region. The simulation results indicate that the breakdown voltage decreases linearly with the implantation dose and a high implantation energy can minimize the impact of the screening SiO2 thickness on the breakdown voltage. Additionally, some key process parameters implemented in coming fabrication have been obtained.

  1. Tests of the new STIC scintillator ring prototype, the photomultipliers and optic fibers cables of the 40 deg C counters

    International Nuclear Information System (INIS)

    Silva, Tatiana da

    1997-01-01

    This paper reports the tests performed on the semicircular prototype of the new scintillator ring with readings obtained by WLS optic fibers. The prototype intends to verify the light collecting and investigate a method for fiber gluing in a circular surface, without the appearing of air bubbles which may restrain the light transmission. Also the optic fiber cables and the photomultipliers used in the 40 deg C counters have been tested in order to verify the electromagnetic energy which may leak from failures in the barrel, aiming the hermeticity enhancement, and also the existence of any damaged cable

  2. Silicon photomultipliers: On ground characterizations and modelling for use in front-end electronics aimed to space-borne experiments

    Energy Technology Data Exchange (ETDEWEB)

    Badoni, Davide [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy)]. E-mail: davide.badoni@roma2.infn.it; Altamura, Francesco [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Basili, Alessandro [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Bencardino, Raffaele [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Bidoli, Vittorio [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Casolino, Marco [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); De Carli, Anna [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Froysland, Tom [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Marchetti, Marcello [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Messi, Roberto [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Minori, Mauro [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Picozza, Piergiorgio [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Salina, Gaetano [Phy. Dep. Univ. ' Tor Vergata' , Tor Vergata Sect. INFN (Italy); Galper, Arkady [Moscow Engineering and Physics Institute (Russian Federation); Korotkov, Mikhail [Moscow Engineering and Physics Institute (Russian Federation); Popov, Alexander [Moscow Engineering and Physics Institute (Russian Federation)

    2007-03-01

    Silicon Photomultipliers (Si-PM) consist of an array of semiconductor photodiodes joint on the common substrate and operating in limited geiger mode. A new generation of Si-PM is currently under test in INFN Rome Tor Vergata facilities: they consist of a 5625 element, 3*3mm{sup 2} array with an improved light response. These elements have been characterized. Furthermore, a functional model of the Si-PM has been developed to be used in a VLSI development of front-end electronics.

  3. Development and characterisation of silicon photomultipliers with bulk-integrated quench resistors for future applications in particle and astroparticle physics

    International Nuclear Information System (INIS)

    Jendrysik, Christian

    2014-01-01

    This thesis deals with the development and characterisation of a novel silicon photomultiplier concept with bulk-integrated quench resistors. The approach allows the realisation of a free entrance window and high fill factors, which leads to an improvement of the detection efficiency. With first prototype productions a proof of concept was possible. A full characterisation provided promising results, in particular with respect to the photon detection efficiency. By customising the simulation tools, a reliable description of the devices was achieved. In addition, conceptual studies of the next device generation demonstrated the possibility of single cell readout, expanding the application range of those detectors to particle tracking.

  4. Fill tube fitted spheres

    International Nuclear Information System (INIS)

    Ives, B.H.

    1981-01-01

    The high temperature diffusion technique for fuel filling of some future direct drive cryogenic ICF targets may be unacceptable. The following describes a technique of fitting a 1 mm diameter x 6 μm thick glass microsphere with an approx. 50 μm O.D. glass fill tube. The process of laser drilling a 50 μm diameter hole in the microsphere wall, technique for making the epoxy joint between the sphere and fill tube, as well as the assembly procedure are also discussed

  5. Steam generator tube vibration study

    International Nuclear Information System (INIS)

    Enderlin, W.I.

    1986-01-01

    Chemical cleaning has been proposed to remove magnetite buildup in some pressurized water reactor steam generators. The US Nuclear Regulatory Commission (NRC) has expressed concern that such cleaning would combine with the tube denting caused by magnetite formation to enlarge tube/tube support plate clearances, increasing the level of flow-induced vibrations that could lead to unacceptably high tube wear and failure rates. In support of NRC, the Pacific Northwest Laboratory investigated whether such increased clearances would exacerbate tube fretting wear. Using a full-length scale model of a steam generator tube bundle, flow tests were conducted at an instrumented location through clearances representing as-built and post-cleaned tube conditions. Test results indicated little potential for increased tube wear as a result of chemical cleaning, under normal operating conditions at tube support locations similar to that tested

  6. Misdirected minitracheostomy tube

    Directory of Open Access Journals (Sweden)

    Ajmer Singh

    2017-01-01

    Full Text Available We report a patient who after an uneventful coronary artery bypass graft surgery and left ventricular aneurysmorrhaphy developed intracerebral hemorrhage and subsequently required minitracheostomy. Chest X-ray showed misdirected minitracheostomy tube facing upward toward the laryngeal opening which was repositioned using bronchoscope.

  7. A New Resonance Tube

    Science.gov (United States)

    Bates, Alan

    2017-01-01

    The measurement of the speed of sound in air with the resonance tube is a popular experiment that often yields accurate results. One approach is to hold a vibrating tuning fork over an air column that is partially immersed in water. The column is raised and lowered in the water until the generated standing wave produces resonance: this occurs at…

  8. Thoughts of accelerator tubes

    International Nuclear Information System (INIS)

    Larson, J.D.

    1977-01-01

    A brief, subjective review is given of mechanisms that may be limiting electrostatic accelerator tubes to present levels of performance. Suggestions are made for attacking these limitations with the purpose of stimulating the thinking of designers and users of electrostatic accelerators

  9. Thoughts of accelerator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Larson, J D

    1977-01-01

    A brief, subjective review is given of mechanisms that may be limiting electrostatic accelerator tubes to present levels of performance. Suggestions are made for attacking these limitations with the purpose of stimulating the thinking of designers and users of electrostatic accelerators.

  10. Eustachian Tube Dysfunction

    Science.gov (United States)

    ... When it is inflated, the balloon opens a pathway for mucus and air to flow through the tube. This can help it function properly. FDA warning The U.S. Food and Drug Administration (FDA) advises against the use of ear candles. ...

  11. Tube-dwelling invertebrates

    NARCIS (Netherlands)

    Hölker, Franz; Vanni, Michael J.; Kuiper, Jan J.; Meile, Christof; Grossart, Hans Peter; Stief, Peter; Adrian, Rita; Lorke, Andreas; Dellwig, Olaf; Brand, Andreas; Hupfer, Michael; Mooij, Wolf M.; Nützmann, Gunnar; Lewandowski, Jörg

    2015-01-01

    There is ample evidence that tube-dwelling invertebrates such as chironomids significantly alter multiple important ecosystem functions, particularly in shallow lakes. Chironomids pump large water volumes, and associated suspended and dissolved substances, through the sediment and thereby compete

  12. Chest tube insertion

    Science.gov (United States)

    ... of your chest cavity. This is called the pleural space. It is done to allow your lungs to fully expand. ... pneumothorax ) Fluid buildup in the chest (called a pleural ... in the esophagus (the tube that allows food to go from the mouth ...

  13. Large-Area, UV-Optimized, Back-Illuminated Silicon Photomultiplier Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Existing photocathode-based technologies for visible and UV instruments lack sensitivity, are bulky, and have limited reliability. Solid-state silicon...

  14. Time resolution of Burle 85001 micro-channel plate photo-multipliers in comparison with Hamamatsu R2083

    Energy Technology Data Exchange (ETDEWEB)

    V. Baturin; V. Burkert; W. Kim; S. Majewsky; D. Nekrasov; K. Park; V. Popov; E. S. Smith; D. Son; S. S. Stepanyan; C. Zorn

    2005-06-01

    The CLAS detector will require improvements in its particle identification system to take advantage of the higher energies provided by the Jefferson Laboratory accelerator upgrade to 12 GeV. To this end, we have studied the timing characteristics of the micro-channel plate photo-multiplier 85001 from Burle, which can be operated in a high magnetic field environment. For reference and comparison, measurements were also made using the standard PMT R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters 2cm x 3cm x 50cm with PMs at the ends, yields 59.1(0.7)ps. The location method of particles from radiative source with known coordinates has been used to compare timing resolutions of R2083 and Burle-85001. This ''coordinate method'' requires only one counter instrumented with two PMs and it yields 59.5(0.7)ps. For the micro-channel plate photomultiplier from Burle with an external amplification of 10 to the signals, the co ordinate method yields 130(4)ps. This method also makes it possible to estimate the number of primary photo-electrons.

  15. Drift tubes of Linac 2

    CERN Multimedia

    Photographic Service

    1977-01-01

    Being redied for installation, those at the right are for tank 1, those on the left for tank 2. Contrary to Linac 1, which had drift-tubes supported on stems, here the tubes are suspended, for better mechanical stability.

  16. Rubens Flame-Tube Demonstration.

    Science.gov (United States)

    Ficken, George W.; Stephenson, Francis C.

    1979-01-01

    Investigates and explains the phenomenon associated with Rubens flame-tube demonstration, specifically the persistance of flames at regular intervals along the tube for few minutes after the gas is turned off. (GA)

  17. Prospects for stronger calandria tubes

    International Nuclear Information System (INIS)

    Ells, C.E.; Coleman, C.E.; Hosbons, R.R.; Ibrahim, E.F.; Doubt, G.L.

    1990-12-01

    The CANDU calandria tubes, made of seam welded and annealed Zircaloy-2, have given exemplary service in-reactor. Although not designed as a system pressure containment, calandria tubes may remain intact even in the face of pressure tube rupture. One such incident at Pickering Unit 2 demonstrated the economic advantage of such an outcome, and a case can be made for increasing the probability that other calandria tubes would perform in a similar fashion. Various methods of obtaining stronger calandria tubes are available, and reviewed here. When the tubes are internally pressurized, the weld is the weak section of the tube. Increasing the oxygen concentration in the starting sheet, and thickening the weld, are promising routes to a stronger tube

  18. Expansion lyre-shaped tube

    International Nuclear Information System (INIS)

    Andro, Jean.

    1973-01-01

    The invention relates the expansion lyre-shaped tube portions formed in dudgeoned tubular bundles between two bottom plates. An expansion lyre comprises at least two sets of tubes of unequal lengths coplanar and symmetrical with respect to the main tube axis, with connecting portions between the tubes forming said sets. The invention applies to apparatus such as heat exchangers, heaters, superheaters or breeders [fr

  19. NEI You Tube Videos: Amblyopia

    Science.gov (United States)

    ... NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low ...

  20. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low ...

  1. Neutron image intensifier tubes

    International Nuclear Information System (INIS)

    Verat, M.; Rougeot, H.; Driard, B.

    1983-01-01

    The most frequently used techniques in neutron radiography employ a neutron converter consisting of either a scintillator or a thin metal sheet. The radiation created by the neutrons exposes a photographic film that is in contact with the converter: in the direct method, the film is exposed during the time that the object is irradiated with neutrons; in the transfer method, the film is exposed after the irradiation of the object with neutrons. In industrial non-destructive testing, when many identical objects have to be checked, these techniques have several disadvantages. Non-destructive testing systems without these disadvantages can be constructed around neutron-image intensifier tubes. A description and the operating characteristics of neutron-image intensifier tubes are given. (Auth.)

  2. Neural tube defects

    Directory of Open Access Journals (Sweden)

    M.E. Marshall

    1981-09-01

    Full Text Available Neural tube defects refer to any defect in the morphogenesis of the neural tube, the most common types being spina bifida and anencephaly. Spina bifida has been recognised in skeletons found in north-eastern Morocco and estimated to have an age of almost 12 000 years. It was also known to the ancient Greek and Arabian physicians who thought that the bony defect was due to the tumour. The term spina bifida was first used by Professor Nicolai Tulp of Amsterdam in 1652. Many other terms have been used to describe this defect, but spina bifida remains the most useful general term, as it describes the separation of the vertebral elements in the midline.

  3. Tomographic visualization of stress corrosion cracks in tubing

    International Nuclear Information System (INIS)

    Morris, R.A.; Kruger, R.P.; Wecksung, G.W.

    1979-06-01

    A feasibility study was conducted to determine the possibility of detecting and sizing cracks in reactor cooling water tubes using tomographic techniques. Due to time and financial constraints, only one tomographic reconstruction using the best technique available was made. The results indicate that tomographic reconstructions can, in fact, detect cracks in the tubing and might possibly be capable of measuring the depth of the cracks. Limits of detectability and sensitivity have not been determined but should be investigated in any future work

  4. Large-Area, UV-Optimized, Back-Illuminated Silicon Photomultiplier Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Large-area (3m2), UV-sensitive focal plane arrays are needed for observation of air showers from ultra-high energy cosmic rays (JEM-EUSO) as well as for...

  5. Instrumented tube burns: theoretical and experimental observations

    Energy Technology Data Exchange (ETDEWEB)

    Yarrington, Cole Davis [Los Alamos National Laboratory; Obrey, Stephen J [Los Alamos National Laboratory; Foley, Timothy J [Los Alamos National Laboratory; Son, Steven F [Los Alamos National Laboratory

    2009-01-01

    The advent of widely available nanoscale energetic composites has resulted in a flurry of novel applications. One of these applications is the use of nanomaterials in energetic compositions. In compositions that exhibit high sensitivity to stimulus, these materials are often termed metastable intermolecular composites (MIC). More generally, these compositions are simply called nanoenergetics. Researchers have used many different experimental techniques to analyze the various properties of nanoenergetic systems. Among these various techniques, the confined tube burn is a simple experiment that is capable of obtaining much data related to the combustion of these materials. The purpose of this report is to review the current state of the confined tube burn experiment, including the drawbacks of the technique and possible remedies. As this report is intended to focus on the specific experimental technique, data from many different energetic materials, and experimental configurations will be presented. The qualitative and quantitative data that can be gathered using confined tube burn experiments include burning rates, total impulse, pressure rise rate, and burning rate differences between different detector types. All of these measurements lend insight into the combustion properties and mechanisms of specific nanoenergetics. Finally, certain data indicates a more complicated flow scenario which may need to be considered when developing burn tube models.

  6. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  7. CRL X-RAY TUBE

    OpenAIRE

    Kolchevsky, N. N.; Petrov, P. V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed.

  8. Experimental and numerical studies of choked flow through adiabatic and diabatic capillary tubes

    International Nuclear Information System (INIS)

    Deodhar, Subodh D.; Kothadia, Hardik B.; Iyer, K.N.; Prabhu, S.V.

    2015-01-01

    Capillary tubes are extensively used in several cooling applications like refrigeration, electronic cooling etc. Local pressure variation in adiabatic straight capillary tube (mini channel) is studied experimentally and numerically with R134a as the working fluid. Experiments are performed on two straight capillary tubes. It is found that the diameter is the most sensitive design parameter of the capillary tube. Experiments are performed on five helically coiled capillary tubes to quantify the effect of pitch and curvature of helically coiled capillary tube on the pressure drop. Non dimensionalized factor to account coiling of capillary tube is derived to calculate mass flow rate in helically coiled capillary tubes. Flow visualization in adiabatic capillary tube confirms the bubbly nature of two phase flow. Numerical and experimental investigations in diabatic capillary tube suggest that the use of positive displacement pump and choking at the exit of the channel ensures flow stability. - Highlights: • Model is developed to design capillary tube in adiabatic and diabatic condition. • Effect of coil curvature on pressure drop is studied experimentally. • Correlation is developed to predict mass flow rate in helical capillary tubes. • Flow visualization is carried out to check the type of two phase flow. • Effect of choked flow on diabatic capillary tubes is studied experimentally.

  9. A luminescence imaging system based on a CCD camera

    DEFF Research Database (Denmark)

    Duller, G.A.T.; Bøtter-Jensen, L.; Markey, B.G.

    1997-01-01

    of the spectrum, the CCD system is less sensitive than the standard bi-alkali photocathode photomultipliers that are commonly used. However, the CCD has a peak performance between 500 and 900 nm. and is more sensitive than the photomultiplier tube over this range. (C) 1997 Elsevier Science Ltd....

  10. Development of the first prototypes of Silicon PhotoMultiplier (SiPM) at ITC-irst

    Energy Technology Data Exchange (ETDEWEB)

    Dinu, N. [INFN Sezione di Padova (Gruppo Collegato di Trento), Trento 38050 (Italy)]. E-mail: dinu@itc.it; Battiston, R. [Universita di Perugia and INFN Sezione di Perugia, Perugia 06123 (Italy); Boscardin, M. [ITC-irst, Divisione Microsistemi, Trento 38050 (Italy); Collazuol, G. [Scuola Normale Superiore and INFN Sezione di Pisa, Pisa 56127 (Italy); Corsi, F. [DEE-Politecnico di Bari and INFN Sezione di Bari, Bari I-70125 (Italy); Dalla Betta, G.F. [INFN Sezione di Padova (Gruppo Collegato di Trento), Trento 38050 (Italy); Dipartimento di Informatica e Telecomunicazioni, Universita di Trento, Trento 38050 (Italy); Del Guerra, A. [Dipartimento di Fisica ' E. Fermi' and INFN Sezione di Pisa, Pisa 56127 (Italy); Llosa, G. [Dipartimento di Fisica ' E. Fermi' and INFN Sezione di Pisa, Pisa 56127 (Italy); Ionica, M. [Universita di Perugia and INFN Sezione di Perugia, Perugia 06123 (Italy); Levi, G. [Dipartimento di Fisica and INFN Sezione di Bologna, Bologna 40127 (Italy); Marcatili, S. [Dipartimento di Fisica ' E. Fermi' and INFN Sezione di Pisa, Pisa 56127 (Italy); Marzocca, C. [DEE-Politecnico di Bari and INFN Sezione di Bari, Bari I-70125 (Italy); Piemonte, C. [ITC-irst, Divisione Microsistemi, Trento 38050 (Italy); Pignatel, G. [Universita di Perugia and INFN Sezione di Perugia, Perugia 06123 (Italy); Pozza, A. [ITC-irst, Divisione Microsistemi, Trento 38050 (Italy); Quadrani, L. [Dipartimento di Fisica and INFN Sezione di Bologna, Bologna 40127 (Italy); Sbarra, C. [Centro Studi e Ricerche ' E. Fermi' , Compendio Viminale, 00184 Rome (Italy); Zorzi, N. [ITC-irst, Divisione Microsistemi, Trento 38050 (Italy)

    2007-03-01

    In the frame of INFN-ITC-irst collaboration new Silicon PhotoMultiplier (SiPM) prototypes have been produced at ITC-irst (Trento, Italy). Each SiPM covers an area of 1 mm{sup 2} and brings together 625 micro-cells of 40x40 {mu}m{sup 2} size connected in parallel as to form a single read-out element. Each micro-cell consists of a Geiger Mode Avalanche Photodiode (GM-APD) in series with its quenching resistance. This article reports the main characteristics of these prototypes as well as the ongoing activity of our collaboration on the development of SiPM devices for medical and space physics applications.

  11. Silicon photomultiplier arrays - a novel photon detector for a high resolution tracker produced at FBK-irst, Italy

    International Nuclear Information System (INIS)

    Greim, R.; Gast, H.; Kirn, T.; Olzem, J.; Yearwood, G. Roper; Schael, S.; Zimmermann, N.; Ambrosi, G.; Azzarello, P.; Battiston, R.; Piemonte, C.

    2009-01-01

    A silicon photomultiplier (SiPM) array has been developed at FBK-irst [Piemonte C., Nucl. Instrum. Methods A, 568 (2006) 224; Piemonte C. et al., IEEE Trans. Nucl. Sci., 54 (2007) 236] having 32 channels and a dimension of 8.0x1.1mm 2 . Each 250 μm wide channel is subdivided into 5x22 rectangularly arranged pixels. These sensors are developed to read out a modular high resolution scintillating fiber tracker. Key properties like breakdown voltage, gain and photon detection efficiency (PDE) are found to be homogeneous over all 32 channels of an SiPM array. This could make scintillating fiber trackers with SiPM array readout a promising alternative to available tracker technologies, if noise properties and the PDE are improved.

  12. Silicon photomultiplier arrays - a novel photon detector for a high resolution tracker produced at FBK-irst, Italy

    Energy Technology Data Exchange (ETDEWEB)

    Greim, R.; Gast, H.; Kirn, T.; Olzem, J.; Yearwood, G. Roper; Schael, S.; Zimmermann, N. [I. Physikalisches Institut B, RWTH Aachen University, 52074 Aachen (Germany); Ambrosi, G.; Azzarello, P. [Dipartimento di Fisica, Universita di Perugia, 06123 Perugia (Italy); Battiston, R. [Dipartimento di Fisica, Universita di Perugia, 06123 Perugia (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Perugia, 06123 Perugia (Italy); Piemonte, C. [Fondazione Bruno Kessler - Istituto per la Ricerca Scientifica e tecnologica, 38050 Trento (Italy)

    2009-12-15

    A silicon photomultiplier (SiPM) array has been developed at FBK-irst [Piemonte C., Nucl. Instrum. Methods A, 568 (2006) 224; Piemonte C. et al., IEEE Trans. Nucl. Sci., 54 (2007) 236] having 32 channels and a dimension of 8.0x1.1mm{sup 2}. Each 250 mum wide channel is subdivided into 5x22 rectangularly arranged pixels. These sensors are developed to read out a modular high resolution scintillating fiber tracker. Key properties like breakdown voltage, gain and photon detection efficiency (PDE) are found to be homogeneous over all 32 channels of an SiPM array. This could make scintillating fiber trackers with SiPM array readout a promising alternative to available tracker technologies, if noise properties and the PDE are improved.

  13. Performance of a compact position-sensitive photon counting detector with image charge coupling to an air-side anode

    Science.gov (United States)

    Jagutzki, O.; Czasch, A.; Schössler, S.

    2013-05-01

    We discuss a novel micro-channel plate (MCP) photomultiplier with resistive screen (RS-PMT) as a detection device for space- and time-correlated single photon counting, illustrated by several applications. The photomultiplier tube resembles a standard image intensifier device. However, the rear phosphor screen is replaced by a ceramic "window" with resistive coating. The MCP output is transferred through the ceramic plate to the read-out electrode (on the air side) via capacity-coupling of the image charge. This design allows for an easy reconfiguration of the read-out electrode (e.g. pixel, charge-sharing, cross-strip, delay-line) without breaking the vacuum for optimizing the detector performance towards a certain task. It also eases the design and manufacturing process of such a multi-purpose photomultiplier tube. Temporal and spatial resolutions well below 100 ps and 100 microns, respectively, have been reported at event rates as high as 1 MHz, for up to 40 mm effective detection diameter. In this paper we will discuss several applications like wide-field fluorescence microscopy and dual γ/fast-neutron radiography for air cargo screening and conclude with an outlook on large-area detectors for thermal neutrons based on MCPs.

  14. Silicon photomultipliers in scintillation detectors used for gamma ray energies up to 6.1 MeV

    Science.gov (United States)

    Grodzicka-Kobylka, M.; Szczesniak, T.; Moszyński, M.; Swiderski, L.; Szawłowski, M.

    2017-12-01

    Majority of papers concerning scintillation detectors with light readout by means of silicon photomultipliers refer to nuclear medicine or radiation monitoring devices where energy of detected gamma rays do not exceed 2 MeV. Detection of gamma radiation with higher energies is of interest to e.g. high energy physics and plasma diagnostics. The aim of this paper is to study applicability (usefulness) of SiPM light readout in detection of gamma rays up to 6.1 MeV in combination with various scintillators. The reported measurements were made with 3 samples of one type of Hamamatsu TSV (Through-Silicon Via technology) MPPC arrays. These 4x4 channel arrays have a 50 × 50 μm2 cell size and 12 × 12 mm2 effective active area. The following scintillators were used: CeBr3, NaI:Tl, CsI:Tl. During all the tests detectors were located in a climatic chamber. The studies are focused on optimization of the MPPC performance for practical use in detection of high energy gamma rays. The optimization includes selection of the optimum operating voltage in respect to the required energy resolution, dynamic range, linearity and pulse amplitude. The presented temperature tests show breakdown voltage dependence on the temperature change and define requirements for a power supply and gain stabilization method. The energy spectra for energies between 511 keV and 6.1 MeV are also presented and compared with data acquired with a classic photomultiplier XP5212B readout. Such a comparison allowed study of nonlinearity of the tested MPPCs, correction of the energy spectra and proper analysis of the energy resolution.

  15. Free compression tube. Applications

    Science.gov (United States)

    Rusu, Ioan

    2012-11-01

    During the flight of vehicles, their propulsion energy must overcome gravity, to ensure the displacement of air masses on vehicle trajectory, to cover both energy losses from the friction between a solid surface and the air and also the kinetic energy of reflected air masses due to the impact with the flying vehicle. The flight optimization by increasing speed and reducing fuel consumption has directed research in the aerodynamics field. The flying vehicles shapes obtained through studies in the wind tunnel provide the optimization of the impact with the air masses and the airflow along the vehicle. By energy balance studies for vehicles in flight, the author Ioan Rusu directed his research in reducing the energy lost at vehicle impact with air masses. In this respect as compared to classical solutions for building flight vehicles aerodynamic surfaces which reduce the impact and friction with air masses, Ioan Rusu has invented a device which he named free compression tube for rockets, registered with the State Office for Inventions and Trademarks of Romania, OSIM, deposit f 2011 0352. Mounted in front of flight vehicles it eliminates significantly the impact and friction of air masses with the vehicle solid. The air masses come into contact with the air inside the free compression tube and the air-solid friction is eliminated and replaced by air to air friction.

  16. Shock tube Multiphase Experiments

    Science.gov (United States)

    Middlebrooks, John; Allen, Roy; Paudel, Manoj; Young, Calvin; Musick, Ben; McFarland, Jacob

    2017-11-01

    Shock driven multiphase instabilities (SDMI) are unique physical phenomena that have far-reaching practical applications in engineering and science. The instability is present in high energy explosions, scramjet combustors, and supernovae events. The SDMI arises when a multiphase interface is impulsively accelerated by the passage of a shockwave. It is similar in development to the Richtmyer-Meshkov (RM) instability however, particle-to-gas coupling is the driving mechanism of the SDMI. As particle effects such as lag and phase change become more prominent, the SDMI's development begins to significantly deviate from the RM instability. We have developed an experiment for studying the SDMI in our shock tube facility. In our experiments, a multiphase interface is created using a laminar jet and flowed into the shock tube where it is accelerated by the passage of a planar shockwave. The interface development is captured using CCD cameras synchronized with planar laser illumination. This talk will give an overview of new experiments conducted to examine the development of a shocked cylindrical multiphase interface. The effects of Atwood number, particle size, and a second acceleration (reshock) of the interface will be discussed.

  17. Bacterial Biofilms in Jones Tubes.

    Science.gov (United States)

    Ahn, Eric S; Hauck, Matthew J; Kirk Harris, Jonathan; Robertson, Charles E; Dailey, Roger A

    To investigate the presence and microbiology of bacterial biofilms on Jones tubes (JTs) by direct visualization with scanning electron microscopy and polymerase chain reaction (PCR) of representative JTs, and to correlate these findings with inflammation and/or infection related to the JT. In this study, prospective case series were performed. JTs were recovered from consecutive patients presenting to clinic for routine cleaning or recurrent irritation/infection. Four tubes were processed for scanning electron microscopy alone to visualize evidence of biofilms. Two tubes underwent PCR alone for bacterial quantification. One tube was divided in half and sent for scanning electron microscopy and PCR. Symptoms related to the JTs were recorded at the time of recovery. Seven tubes were obtained. Five underwent SEM, and 3 out of 5 showed evidence of biofilms (60%). Two of the 3 biofilms demonstrated cocci and the third revealed rods. Three tubes underwent PCR. The predominant bacteria identified were Pseudomonadales (39%), Pseudomonas (16%), and Staphylococcus (14%). Three of the 7 patients (43%) reported irritation and discharge at presentation. Two symptomatic patients, whose tubes were imaged only, revealed biofilms. The third symptomatic patient's tube underwent PCR only, showing predominantly Staphylococcus (56%) and Haemophilus (36%) species. Two of the 4 asymptomatic patients also showed biofilms. All symptomatic patients improved rapidly after tube exchange and steroid antibiotic drops. Bacterial biofilms were variably present on JTs, and did not always correlate with patients' symptoms. Nevertheless, routine JT cleaning is recommended to treat and possibly prevent inflammation caused by biofilms.

  18. Failure analysis of boiler tube

    International Nuclear Information System (INIS)

    Mehmood, K.; Siddiqui, A.R.

    2007-01-01

    Boiler tubes are energy conversion components where heat energy is used to convert water into high pressure superheated steam, which is then delivered to a turbine for electric power generation in thermal power plants or to run plant and machineries in a process or manufacturing industry. It was reported that one of the tubes of a fire-tube boiler used in a local industry had leakage after the formation of pits at the external surface of the tube. The inner side of the fire tube was working with hot flue gasses with a pressure of 10 Kg/cm/sup 2/ and temperature 225 degree C. The outside of the tube was surrounded by feed water. The purpose of this study was to determine the cause of pits developed at the external surface of the failed boiler tube sample. In the present work boiler tube samples of steel grade ASTM AI61/ASTM A192 were analyzed using metallographic analysis, chemical analysis, and mechanical testing. It was concluded that the appearance of defects on the boiler tube sample indicates cavitation type corrosion failure. Cavitation damage superficially resembled pitting, but surface appeared considerably rougher and had many closely spaced pits. (author)

  19. YouTube and 'psychiatry'.

    Science.gov (United States)

    Gordon, Robert; Miller, John; Collins, Noel

    2015-12-01

    YouTube is a video-sharing website that is increasingly used to share and disseminate health-related information, particularly among younger people. There are reports that social media sites, such as YouTube, are being used to communicate an anti-psychiatry message but this has never been confirmed in any published analysis of YouTube clip content. This descriptive study revealed that the representation of 'psychiatry' during summer 2012 was predominantly negative. A subsequent smaller re-analysis suggests that the negative portrayal of 'psychiatry' on YouTube is a stable phenomenon. The significance of this and how it could be addressed are discussed.

  20. Radiation-resistant camera tube

    International Nuclear Information System (INIS)

    Kuwahata, Takao; Manabe, Sohei; Makishima, Yasuhiro

    1982-01-01

    It was a long time ago that Toshiba launched on manufacturing black-and-white radiation-resistant camera tubes employing nonbrowning face-plate glass for ITV cameras used in nuclear power plants. Now in compliance with the increasing demand in nuclear power field, the Company is at grips with the development of radiation-resistant single color-camera tubes incorporating a color-stripe filter for color ITV cameras used under radiation environment. Herein represented are the results of experiments on characteristics of materials for single color-camera tubes and prospects for commercialization of the tubes. (author)

  1. Learning from YouTube [Video Book

    Science.gov (United States)

    Juhasz, Alexandra

    2011-01-01

    YouTube is a mess. YouTube is for amateurs. YouTube dissolves the real. YouTube is host to inconceivable combos. YouTube is best for corporate-made community. YouTube is badly baked. These are a few of the things Media Studies professor Alexandra Juhasz (and her class) learned about YouTube when she set out to investigate what actually happens…

  2. Scintillation hodoscope with 50x50 cm2 sensitive area on the basis of hodoscopic FEhU's

    International Nuclear Information System (INIS)

    Borog, V.V.; Dronov, V.V.; Vasil'chenko, V.G.; Rykalin, V.I.; Demekhin, A.B.

    1986-01-01

    The problems of choosing optimal constructions of sensitive elements of large hodoscopes on the base of hodoscopic photamultipliers are considered. The obtained results of numerical calculations for choosing optimal constructions and materials of hodoscope elements are confirmed by the results of the performed measurements. The measured spatial resolution of one of constructions of scintillation hodoscopes with the 50x50x2 cm 3 sensitive volume using two hodoscopic photomultipliers constituted ±3 mm

  3. Nasogastric tube syndrome induced by an indwelling long intestinal tube.

    Science.gov (United States)

    Sano, Naoki; Yamamoto, Masayoshi; Nagai, Kentaro; Yamada, Keiichi; Ohkohchi, Nobuhiro

    2016-04-21

    The nasogastric tube (NGT) has become a frequently used device to alleviate gastrointestinal symptoms. Nasogastric tube syndrome (NTS) is an uncommon but potentially life-threatening complication of an indwelling NGT. NTS is characterized by acute upper airway obstruction due to bilateral vocal cord paralysis. We report a case of a 76-year-old man with NTS, induced by an indwelling long intestinal tube. He was admitted to our hospital for treatment of sigmoid colon cancer. He underwent sigmoidectomy to release a bowel obstruction, and had a long intestinal tube inserted to decompress the intestinal tract. He presented acute dyspnea following prolonged intestinal intubation, and bronchoscopy showed bilateral vocal cord paralysis. The NGT was removed immediately, and tracheotomy was performed. The patient was finally discharged in a fully recovered state. NTS be considered in patients complaining of acute upper airway obstruction, not only with a NGT inserted but also with a long intestinal tube.

  4. A New Resonance Tube

    Science.gov (United States)

    Bates, Alan

    2017-12-01

    The measurement of the speed of sound in air with the resonance tube is a popular experiment that often yields accurate results. One approach is to hold a vibrating tuning fork over an air column that is partially immersed in water. The column is raised and lowered in the water until the generated standing wave produces resonance: this occurs at the point where sound is perceived to have maximum loudness, or at the point where the amplitude of the standing wave has maximum value, namely an antinode. An antinode coincides with the position of the tuning fork, beyond the end of the air column, which consequently introduces an end correction. One way to minimize this end correction is to measure the distance between consecutive antinodes.

  5. Piezoelectric Rotary Tube Motor

    Science.gov (United States)

    Fisher, Charles D.; Badescu, Mircea; Braun, David F.; Culhane, Robert

    2011-01-01

    A custom rotary SQUIGGLE(Registered TradeMark) motor has been developed that sets new benchmarks for small motor size, high position resolution, and high torque without gear reduction. Its capabilities cannot be achieved with conventional electromagnetic motors. It consists of piezoelectric plates mounted on a square flexible tube. The plates are actuated via voltage waveforms 90 out of phase at the resonant frequency of the device to create rotary motion. The motors were incorporated into a two-axis postioner that was designed for fiber-fed spectroscopy for ground-based and space-based projects. The positioner enables large-scale celestial object surveys to take place in a practical amount of time.

  6. Pressure tube reactor

    International Nuclear Information System (INIS)

    Matsumoto, Tomoyuki; Fujino, Michihira.

    1980-01-01

    Purpose: To equalize heavy water flow distribution by providing a nozzle for externally injecting heavy water from a vibration preventive plate to the upper portion to feed the heavy water in a pressure tube reactor and swallowing up heavy water in a calandria tank to supply the heavy water to the reactor core above the vibration preventive plate. Constitution: A moderator injection nozzle is mounted on the inner wall of a calandria tank. Heavy water is externally injected above the vibration preventive plate, and heavy water in the calandria tank is swallowed up to supply the heavy water to the core reactor above the vibration preventive plate. Therefore, the heavy water flow distribution can be equalized over the entire reactor core, and the distribution of neutron absorber dissolved in the heavy water is equalized. (Yoshihara, H.)

  7. Primary Fallopian Tube Carcinoma

    Directory of Open Access Journals (Sweden)

    Prasad K Shetty

    2011-01-01

    Full Text Available Primary Fallopian Tube Carcinoma (PFTC is rare and accounts for about 0.3% of all gynecologic cancers. Less than 1500 cases have been reported in the literature. It arises in postmenopausal women and typically presents with abdominal pelvic pain, vaginal bleeding and watery discharge. However, a correct diagnosis is rarely achieved preoperative, and in many cases, the diagnosis is made after incidental surgery for unrelated conditions commonly being ovarian carcinoma . Compared with ovarian carcinoma, PFTC more often presents at early stages, but it has a worse prognosis. PFTC is usually managed in the same manner as ovarian cancer. We report a case of Left PFTC that presented as Left ovarian mass, and we briefly review the literature.

  8. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  9. Characterization of tube support alloys

    International Nuclear Information System (INIS)

    Vaia, A.R.

    1985-01-01

    The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions

  10. Flaming on YouTube

    NARCIS (Netherlands)

    Moor, Peter J.; Heuvelman, A.; Verleur, R.

    2010-01-01

    In this explorative study, flaming on YouTube was studied using surveys of YouTube users. Flaming is defined as displaying hostility by insulting, swearing or using otherwise offensive language. Three general conclusions were drawn. First, although many users said that they themselves do not flame,

  11. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia NEI Home Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  12. 27 CFR 40.352 - Cigarette tubes.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Cigarette tubes. 40.352... OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED TOBACCO Manufacture of Cigarette Papers and Tubes Taxes § 40.352 Cigarette tubes. Cigarette tubes...

  13. Study on Acoustic Catheter of Boiler Tube Leakage Monitoring Systems

    Science.gov (United States)

    Lv, Yongxing; Feng, Qiang

    Boiler tube leakage is the major reason of affecting the safe operation of the unit now, there are 3 methods of the "four tube" leakage detection: Traditional method, filtering method and acoustic spectrum analysis, acoustic spectrum analysis is the common method, but this method have low sensitivity and the sensor damage easily. Therewith, designed the special acoustic catheter with acoustic resonance cavity type, proved by experiments, the acoustic catheter with acoustic resonance cavity type can enhance leakage sound, can accurately extract leakage signals, has high sensitivity, and can avoid the effect of sensor by fire and hot-gas when the furnace is in positive pressure situation, reduce the installation and maintenance costs of the boiler tube leakage monitor system.

  14. Practical acoustic thermometry with twin-tube and single-tube sensors

    International Nuclear Information System (INIS)

    De Podesta, M.; Sutton, G.; Edwards, G.; Stanger, L.; Preece, H.

    2015-01-01

    Accurate measurement of high temperatures in a nuclear environment presents unique challenges. All secondary techniques inevitably drift because the thermometric materials in thermocouples and resistance sensors are sensitive not just to temperature, but also their own chemical and physical composition. The solution is to use primary methods that rely on fundamental links between measurable physical properties and temperature. In the nuclear field the best known technique is the measurement of Johnson Noise in a resistor (See Paper 80 at this conference). In this paper we describe the measurement of temperature in terms of the speed of sound in a gas confined in a tube - an acoustic waveguide. Acoustic thermometry is the most accurate technique of primary thermometry ever devised with the best uncertainty of measurement below 0.001 C. In contrast, the acoustic technique described in this work has a much larger uncertainty, approximately 1 deg. C. But the cost and ease of use are improved by several orders of magnitude, making implementation eminently practical. We first describe the basic construction and method of operation of thermometers using twin-tubes and single tubes. We then present results using a twin-tube design showing that showing long term stability (i.e. no detectable drift) at 700 deg. C over periods of several weeks. We then outline how the technique may be developed for different nuclear applications. (authors)

  15. HF electronic tubes. Technologies, grid tubes and klystrons

    International Nuclear Information System (INIS)

    Lemoine, Th.

    2009-01-01

    This article gives an overview of the basic technologies of electronic tubes: cathodes, electronic optics, vacuum and high voltage. Then the grid tubes, klystrons and inductive output tubes (IOT) are introduced. Content: 1 - context and classification; 2 - electronic tube technologies: cathodes, electronic optics, magnetic confinement (linear tubes), periodic permanent magnet (PPM) focussing, collectors, depressed collectors; 3 - vacuum technologies: vacuum quality, surface effects and interaction with electrostatic and RF fields, secondary emission, multipactor effect, thermo-electronic emission; 4 - grid tubes: operation of a triode, tetrodes, dynamic operation and classes of use, 'common grid' and 'common cathode' operation, ranges of utilisation and limitations, operation of a tetrode on unadjusted load, lifetime of a tetrode, uses of grid tubes; 5 - klystrons: operation, impact of space charge, multi-cavity klystrons, interaction efficiency, extended interaction klystrons, relation between interaction efficiency, perveance and efficiency, ranges of utilization and power limitations, multi-beam klystrons and sheet beam klystrons, operation on unadjusted load, klystron band pass and lifetime, uses; 6 - IOT: principle of operation, ranges of utilisation and limitations, interaction efficiency and depressed collector IOT, IOT lifetime and uses. (J.S.)

  16. Method for estimating off-axis pulse tube losses

    Science.gov (United States)

    Fang, T.; Mulcahey, T. I.; Taylor, R. P.; Spoor, P. S.; Conrad, T. J.; Ghiaasiaan, S. M.

    2017-12-01

    Some Stirling-type pulse tube cryocoolers (PTCs) exhibit sensitivity to gravitational orientation and often exhibit significant cooling performance losses unless situated with the cold end pointing downward. Prior investigations have indicated that some coolers exhibit sensitivity while others do not; however, a reliable method of predicting the level of sensitivity during the design process has not been developed. In this study, we present a relationship that estimates an upper limit to gravitationally induced losses as a function of the dimensionless pulse tube convection number (NPTC) that can be used to ensure that a PTC would remain functional at adverse static tilt conditions. The empirical relationship is based on experimental data as well as experimentally validated 3-D computational fluid dynamics simulations that examine the effects of frequency, mass flow rate, pressure ratio, mass-pressure phase difference, hot and cold end temperatures, and static tilt angle. The validation of the computational model is based on experimental data collected from six commercial pulse tube cryocoolers. The simulation results are obtained from component-level models of the pulse tube and heat exchangers. Parameter ranges covered in component level simulations are 0-180° for tilt angle, 4-8 for length to diameter ratios, 4-80 K cold tip temperatures, -30° to +30° for mass flow to pressure phase angles, and 25-60 Hz operating frequencies. Simulation results and experimental data are aggregated to yield the relationship between inclined PTC performance and pulse tube convection numbers. The results indicate that the pulse tube convection number can be used as an order of magnitude indicator of the orientation sensitivity, but CFD simulations should be used to calculate the change in energy flow more accurately.

  17. Study of light detection and sensitivity for a ton-scale liquid xenon dark matter detector

    International Nuclear Information System (INIS)

    Wei, Y; Lin, Q; Xiao, X; Ni, K

    2013-01-01

    Ton-scale liquid xenon detectors operated in two-phase mode are proposed and being constructed recently to explore the favored parameter space for the Weakly Interacting Massive Particles (WIMPs) dark matter. To achieve a better light collection efficiency while limiting the number of electronics channels compared to the previous generation detectors, large-size photo-multiplier tubes (PMTs) such as the 3-inch-diameter R11410 from Hamamatsu are suggested to replace the 1-inch-square R8520 PMTs. In a two-phase xenon dark matter detector, two PMT arrays on the top and bottom are usually used. In this study, we compare the performance of two different ton-scale liquid xenon detector configurations with the same number of either R11410 (config.1) or R8520 (config.2) for the top PMT array, while both using R11410 PMTs for the bottom array. The self-shielding of liquid xenon suppresses the background from the PMTs and the dominant background is from the pp solar neutrinos in the central fiducial volume. The light collection efficiency for the primary scintillation light is largely affected by the xenon purity and the reflectivity of the reflectors. In the optimistic situation with a 10 m light absorption length and a 95% reflectivity, the light collection efficiency is 43%(34%) for config.1(config.2). In the conservative situation with a 2.5 m light absorption length and a 85% reflectivity, the value is only 18%(13%) for config.1(config.2). The difference between the two configurations is due to the larger PMT coverage on the top for config.1. The slightly different position resolutions for the two configurations have a negligible effect on the sensitivity. Based on the above considerations, we estimate the sensitivity reach of the two detector configurations. Both configurations can reach a sensitivity of 2 ∼ 3 × 10 −47 cm 2 for spin-independent WIMP-nucleon cross section for 100 GeV/c 2 WIMPs after two live-years of operation. The one with R8520 PMTs for the top

  18. Pulsed Drift Tube Accelerator

    International Nuclear Information System (INIS)

    Faltens, A.

    2004-01-01

    The pulsed drift-tube accelerator (DTA) concept was revived by Joe Kwan and John Staples and is being considered for the HEDP/WDM application. It could be used to reach the full energy or as an intermediate accelerator between the diode and a high gradient accelerator such as multi-beam r.f. In the earliest LBNL HIF proposals and conceptual drivers it was used as an extended injector to reach energies where an induction linac with magnetic quadrupoles is the best choice. For HEDP, because of the very short pulse duration, the DTA could provide an acceleration rate of about 1MV/m. This note is divided into two parts: the first, a design based on existing experience; the second, an optimistic extrapolation. The first accelerates 16 parallel K + beams at a constant line charge density of 0.25(micro) C/m per beam to 10 MeV; the second uses a stripper and charge selector at around 4MeV followed by further acceleration to reach 40 MeV. Both benefit from more compact sources than the present 2MV injector source, although that beam is the basis of the first design and is a viable option. A pulsed drift-tube accelerator was the first major HIF experiment at LBNL. It was designed to produce a 2(micro)s rectangular 1 Ampere C s + beam at 2MeV. It ran comfortably at 1.6MeV for several years, then at lower voltages and currents for other experiments, and remnants of that experiment are in use in present experiments, still running 25 years later. The 1A current, completely equivalent to 1.8A K + , was chosen to be intermediate between the beamlets appropriate for a multi-beam accelerator, and a single beam of, say, 10A, at injection energies. The original driver scenarios using one large beam on each side of the reactor rapidly fell out of favor because of the very high transverse and longitudinal fields from the beam space charge, circa 1MV/cm and 250 kV/cm respectively, near the chamber and because of aberrations in focusing a large diameter beam down to a 1mm radius spot at a

  19. Water-storage-tube systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hemker, P.

    1981-12-24

    Passive solar collection/storage/distribution systems were surveyed, designed, fabricated, and mechanically and thermally tested. The types studied were clear and opaque fiberglass tubes, metal tubes with plastic liners, and thermosyphoning tubes. (MHR)

  20. Conditioning and breakdown phenomena in accelerator tubes

    International Nuclear Information System (INIS)

    Skorka, S.J.

    1979-01-01

    Important breakdown mechanisms in accelerator tubes are reviewed, and discharge phenomena in NEC tubes are deduced from the surface appearance of the electrodes and insulators of a used tube. Microphotos of these surfaces are shown

  1. Eddy current signal comparison for tube identification

    Science.gov (United States)

    Glass, S. W.; Vojvodic, R.

    2015-03-01

    Inspection of nuclear power plant steam generator tubes is required to justify continued safe plant operation. The steam generators consist of thousands of tubes with nominal diameters of 15 to 22mm, approximately 1mm wall thickness, and 20 to 30m in length. The tubes are inspected by passing an eddy current probe through the tubes from tube end to tube end. It is critical to know exactly which tube identification (row and column) is associated with each tube's data. This is controlled by a precision manipulator that provides the tube ID to the eddy current system. Historically there have been some instances where the manipulator incorrectly reported the tube ID. This can have serious consequences including lack of inspection of a tube, or if a pluggable indication is detected, the tube is likely to be mis-plugged thereby risking a primary to secondary leak.

  2. [Correlation of fine structures of distributions of amplitudes of a photomultiplier dark current fluctuations with the Earth rotations about its axis].

    Science.gov (United States)

    Fedorov, M V; Belousov, L V; Voeĭkov, V L; Zenchenko, K I; Zenchenko, T A; Konradov, A A; Shnol', S E

    2001-01-01

    The fine structures of distributions of photomultiplier dark current fluctuations measured in two laboratories 2000 km distant from other: in the international Institute of Biophysics (Neuss, Germany) and in the Moscow State University (Moscow, Russia) were compared. It is shown that similar forms of appropriate histograms are apparently more often realized at both locations at the same local time. This confirms the previous conclusion that the fine structure of distributions correlates with rotation of the Earth about its axis.

  3. STiC — a mixed mode silicon photomultiplier readout ASIC for time-of-flight applications

    International Nuclear Information System (INIS)

    Harion, T; Briggl, K; Chen, H; Gil, A; Kiworra, V; Schultz-Coulon, H-C; Shen, W; Stankova, V; Fischer, P; Ritzert, M

    2014-01-01

    STiC is an application specific integrated circuit (ASIC) for the readout of silicon photomultipliers. The chip has been designed to provide a very high timing resolution for time-of-flight applications in medical imaging and particle physics. It is dedicated in particular to the EndoToFPET-US project, which is developing an endoscopic PET detector combined with ultrasound imaging for early pancreas and prostate cancer detection. This PET system aims to provide a spatial resolution of 1 mm and a time-of-flight resolution of 200 ps FWHM. The analog frontend of STiC can use either a differential or single ended connection to the SiPM. The time and energy information of the detector signal is encoded into two time stamps. A special linearized time-over-threshold method is used to obtain a linear relation between the signal charge and the measured signal width, improving the energy resolution. The trigger signals are digitized by an integrated TDC module with a resolution of less than 20 ps. The TDC data is stored in an internal memory and transfered over a 160 MBit/s serial link using 8/10 bit encoding. First coincidence measurements using a 3.1 × 3.1 × 15 mm 3 LYSO crystal and a S10362-33-50 Hamamtsu MPPC show a coincidence time resolution of less than 285 ps. We present details on the chip design as well as first characterization measurements

  4. Time-of-flight resolution of scintillating counters with Burle 85001 microchannel plate photomultipliers in comparison with Hamamatsu R2083

    Energy Technology Data Exchange (ETDEWEB)

    Baturin, V. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Burkert, V. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Kim, W. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of)]. E-mail: wooyoung@jlab.org; Majewsky, S. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Park, K. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Popov, V. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Smith, E.S. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Son, D. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Stepanyan, S.S. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Zorn, C. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States)

    2006-06-15

    Improvements in the time resolution of the CEBAF Large Acceptance Spectrometer (CLAS) below {approx}50ps will be required for experiments using the planned upgraded accelerator facility at Jefferson Lab. The improved time resolution will allow particle identification using time-of-flight techniques to be used effectively up to the proposed operating energy of 12GeV. The challenge of achieving this time resolution over a relatively large area is compounded because the photomultipliers (PM) in the CLAS 'time-zero' scintillating counters must operate in very high magnetic fields. Therefore, we have studied the resolution of 'time-zero' prototypes with microchannel plate PMs 85001-501 from Burle. For reference and comparison, measurements were also made using the standard PMs R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters (Bicron BC-408, 2x3x50cm{sup 3}) with PMs at the ends, yields {sigma}{sub R2083}=59.1+/-0.7ps. The location method of particles from a radiative source with known coordinates has been used to compare timing resolutions of R2083 and 85001-501. This method yields {sigma}{sub R2083}=59.5+/-0.7ps and it also provides an estimate of the number of primary photoelectrons. For the microchannel plate PM from Burle the method yields {sigma}{sub 85001}=130+/-4ps due to lower number of primary photoelectrons.

  5. Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier

    Science.gov (United States)

    Israelashvili, I.; Coimbra, A. E. C.; Vartsky, D.; Arazi, L.; Shchemelinin, S.; Caspi, E. N.; Breskin, A.

    2017-09-01

    Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe converter/scintillator, coupled to a triple-THGEM imaging-GPM, with its first electrode coated by a CsI UV-photocathode, operated in Ne/5%CH4 at cryogenic temperatures. Radiation localization in 2D was derived from scintillation-induced photoelectron avalanches, measured on the GPM's segmented anode. The localization properties of 60Co gamma-rays and a mixed fast-neutron/gamma-ray field from an AmBe neutron source were derived from irradiation of a Pb edge absorber. Spatial resolutions of 12± 2 mm and 10± 2 mm (FWHM) were reached with 60Co and AmBe sources, respectively. The experimental results are in good agreement with GEANT4 simulations. The calculated ultimate expected resolutions for our application-relevant 4.4 and 15.1 MeV gamma-rays and 1-15 MeV neutrons are 2-4 mm and ~ 2 mm (FWHM), respectively. These results indicate the potential applicability of the new detector concept to Fast-Neutron Resonance Radiography (FNRR) and Dual-Discrete-Energy Gamma Radiography (DDEGR) of large objects.

  6. Challenges of arbitrary waveform signal detection by Silicon Photomultipliers as readout for Cherenkov fibre based beam loss monitoring systems

    CERN Document Server

    Vinogradov, Sergey; Nebot del Busto, Eduardo; Kastriotou, Maria; Welsch, Carsten P

    2016-01-01

    Silicon Photomultipliers (SiPMs) are well recognised as very competitive photodetectors due to their exceptional photon number and time resolution, room-temperature low-voltage operation, insensitivity to magnetic fields, compactness, and robustness. Detection of weak light pulses of nanosecond time scale appears to be the best area for SiPM applications because in this case most of the SiPM drawbacks have a rather limited effect on its performance. In contrast to the more typical scintillation and Cherenkov detection applications, which demand information on the number of photons and/or the arrival time of the light pulse only, beam loss monitoring (BLM) systems utilising Cherenkov fibres with photodetector readout have to precisely reconstruct the temporal profile of the light pulse. This is a rather challenging task for any photon detector especially taking into account the high dynamic range of incident signals (100K – 1M) from a few photons to a few percents of destructive losses in a beam line and pre...

  7. mouseTube

    Science.gov (United States)

    Torquet, Nicolas; de Chaumont, Fabrice; Faure, Philippe; Bourgeron, Thomas; Ey, Elodie

    2016-01-01

    Ultrasonic vocalisation is a broadly used proxy to evaluate social communication in mouse models of neuropsychiatric disorders. The efficacy and robustness of testing these models suffer from limited knowledge of the structure and functions of these vocalisations as well as of the way to analyse the data. We created mouseTube , an open database with a web interface, to facilitate sharing and comparison of ultrasonic vocalisations data and metadata attached to a recording file. Metadata describe 1) the acquisition procedure, e.g ., hardware, software, sampling frequency, bit depth; 2) the biological protocol used to elicit ultrasonic vocalisations; 3) the characteristics of the individual emitting ultrasonic vocalisations ( e.g. , strain, sex, age). To promote open science and enable reproducibility, data are made freely available. The website provides searching functions to facilitate the retrieval of recording files of interest. It is designed to enable comparisons of ultrasonic vocalisation emission between strains, protocols or laboratories, as well as to test different analysis algorithms and to search for protocols established to elicit mouse ultrasonic vocalisations. Over the long term, users will be able to download and compare different analysis results for each data file. Such application will boost the knowledge on mouse ultrasonic communication and stimulate sharing and comparison of automatic analysis methods to refine phenotyping techniques in mouse models of neuropsychiatric disorders.

  8. X-ray tube

    International Nuclear Information System (INIS)

    Mayo, B.J.

    1980-01-01

    An x-ray tube in which the x-ray origin is scanned on a circle around the patient, comprises a ring-shaped anode, an electron beam travelling along a circular path being deflected onto the anode at the desired positions. The electron beam path may be in a plane parallel to the anode and perhaps at the same radius. It may be in the same plane as a transmission target/anode and at a greater radius. The anode should extend over at least 180 0 although it may extend to 360 0 . Electrostatic means may be provided to constrain the beam to the circular path and further electrostatic means deflect it to the anode of the beam and ensure it is focused at the point of incidence. Collimators provide a planar fan-shaped beam and the anode may be shaped to attenuate side lobes of the radiation. Electrode collects electrons not deflected. The focal regions may be adjacent or otherwise. Coils may provide periodic focusing to overcome space charge dispersion and dynamic adjustment of the focusing before deflection ensures focusing at target incidence. Focusing may be absent near the deflection region, and current in the coil section near the focal region should be zero. (author)

  9. Flux tubes at finite temperature

    Energy Technology Data Exchange (ETDEWEB)

    Cea, Paolo [INFN, Sezione di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Dipartimento di Fisica dell’Università di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Cosmai, Leonardo [INFN, Sezione di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Cuteri, Francesca; Papa, Alessandro [Dipartimento di Fisica, Università della Calabria & INFN-Cosenza,Ponte Bucci, cubo 31C, I-87036 Rende (Cosenza) (Italy)

    2016-06-07

    The chromoelectric field generated by a static quark-antiquark pair, with its peculiar tube-like shape, can be nicely described, at zero temperature, within the dual superconductor scenario for the QCD confining vacuum. In this work we investigate, by lattice Monte Carlo simulations of the SU(3) pure gauge theory, the fate of chromoelectric flux tubes across the deconfinement transition. We find that, if the distance between the static sources is kept fixed at about 0.76 fm ≃1.6/√σ and the temperature is increased towards and above the deconfinement temperature T{sub c}, the amplitude of the field inside the flux tube gets smaller, while the shape of the flux tube does not vary appreciably across deconfinement. This scenario with flux-tube “evaporation” above T{sub c} has no correspondence in ordinary (type-II) superconductivity, where instead the transition to the phase with normal conductivity is characterized by a divergent fattening of flux tubes as the transition temperature is approached from below. We present also some evidence about the existence of flux-tube structures in the magnetic sector of the theory in the deconfined phase.

  10. Very low power, high voltage base for a Photo Multiplier Tube for the KM3NeT deep sea neutrino telescope

    International Nuclear Information System (INIS)

    Timmer, P; Heine, E; Peek, H

    2010-01-01

    The described system is developed in the framework of a deep-sea submerged Very Large Volume neutrino Telescope where photons are detected by a large number of Photo Multiplier Tubes. These PMTs are placed in optical modules (OM). A basic Cockcroft-Walton (CW) voltage multiplier circuit design is used to generate multiple voltages to drive the dynodes of the photomultiplier tube. To achieve a long lifetime and a high reliability the dissipation in the OM must be kept to the minimum. The design is also constrained by size restrictions, load current, voltage range, and the maximum allowable ripple in the output voltage. A surface mount PMT-base PCB prototype is designed and successfully tested. The system draws less than 1.5 mA of supply current at a voltage of 3.3 V with outputs up to -1400 Vdc cathode voltage, a factor 10 less than the commercially available state of the art.

  11. Very low power, high voltage base for a Photo Multiplier Tube for the KM3NeT deep sea neutrino telescope

    CERN Document Server

    Timmer, P; Peek, H

    2010-01-01

    The described system is developed in the framework of a deep-sea submerged Very Large Volume neutrino Telescope where photons are detected by a large number of Photo Multiplier Tubes. These PMTs are placed in optical modules (OM). A basic Cockcroft-Walton (CW) voltage multiplier circuit design is used to generate multiple voltages to drive the dynodes of the photomultiplier tube. To achieve a long lifetime and a high reliability the dissipation in the OM must be kept to the minimum. The design is also constrained by size restrictions, load current, voltage range, and the maximum allowable ripple in the output voltage. A surface mount PMT-base PCB prototype is designed and successfully tested. The system draws less than 1.5 mA of supply current at a voltage of 3.3 V with outputs up to -1400 Vdc cathode voltage, a factor 10 less than the commercially available state of the art

  12. Studies on heat shrinkage PVC tubes

    International Nuclear Information System (INIS)

    Pyun, Hyung Chick; Kim, Ki Yup; Nho, Young Chang

    1991-01-01

    Radiation crosslinking of PVC was investigated for the purpose of obtaining a suitable formulation for heat shrinkable tube. PVC was not only compounded with various crosslinking agents and plasticizers to evaluate their effects on the radiation sensitivity, heat shrinkable property and other mechanical properties, but also mixed with NBR, crosslinking agents and plasticizers to obtain efficient crosslinking yield and suitable mechanical properties for heat shrinkable tube. Gel yield of PVC increased with increasing unsaturation levels per molecular weight of crosslinking agents. Among crosslinking agents tested, TMPTMA with three unsaturated groups showed highest gel yield, while PVC containing NBR was more sensitive to crosslinking than PVC itself regardless the types of crosslinking agents and plasticizers. Tensile strength was increased with increasing radiation dose and gel percent, but elongation decreased. It was found that gel percent was increased with increasing radiation dose, heat transformation was decreased with increasing gel percent. When NBR was mixed with PVC, the radiation dosage required for enhancing yield of gel percent and heat transformation were found to be much smaller comparing with the case containing no NBR. Therefore, the addition of NBR to PVC was very effective to increase heat-resisting property of PVC. Heat shrinkage was not much varied with radiation dose, the types of crosslinking agents and plasticizers, but it was increased remarkably with decreasing stretching temperature and increasing annealing temperature. (Author)

  13. PEG tubes: dealing with complications.

    Science.gov (United States)

    Malhi, Hardip; Thompson, Rosie

    A percutaneous endoscopic gastronomy tube can be used to deliver nutrition, hydration and medicines directly into the patient's stomach. Patients will require a tube if they are unable to swallow safely, putting them at risk of aspiration of food, drink and medicines into their lungs. It is vital that nurses are aware of the complications that may arise when caring for a patient with a PEG tube. It is equally important that nurses know how to deal with these complications or from where tc seek advice. This article provides a quick troubleshooting guide to help nurses deal with complications that can arise with PEG feeding.

  14. Rigid inflatable gastrostomy tube malposition

    Directory of Open Access Journals (Sweden)

    Timothy E. Murray, MB, MCh, MRCS, FFR

    2017-12-01

    Full Text Available Rigid inflatable gastrostomy (RIG tubes are widely used in contemporary clinical practice for a variety of indications. Insertion of RIG tubes is associated with a high technical success rate and low incidence of mortality. In this case report, a procedural pitfall associated with intraperitoneal-extragastric malposition is described. Rigorous assessment of abdominal radiographs, as well as awareness of the expected appearance of the RIG tube and gastropexy T-fasteners, allows the abdominal radiologist to detect early RIG position in the early postprocedural period. Abdominal radiography is a widely available and inexpensive technique. The high spatial resolution it provides makes it a valuable tool in determining hardware position.

  15. Expansion tube test time predictions

    Science.gov (United States)

    Gourlay, Christopher M.

    1988-01-01

    The interaction of an interface between two gases and strong expansion is investigated and the effect on flow in an expansion tube is examined. Two mechanisms for the unsteady Pitot-pressure fluctuations found in the test section of an expansion tube are proposed. The first mechanism depends on the Rayleigh-Taylor instability of the driver-test gas interface in the presence of a strong expansion. The second mechanism depends on the reflection of the strong expansion from the interface. Predictions compare favorably with experimental results. The theory is expected to be independent of the absolute values of the initial expansion tube filling pressures.

  16. Panel type X-ray image intensifier tube

    International Nuclear Information System (INIS)

    Wang, S.P.

    1977-01-01

    A panel shaped, proximity type, X-ray image intensifier tube for medical X-ray diagnostic is disclosed. It has all linear components and yet a high brightness gain, in the range of 500 to 20,000 cd-sec/m 2 -R, the tube being comprised of a rugged metallic tube envelope, an inwardly concave metallic input window of full size output display screen, an alkaline-halide scintillator photocathode screen suspended on insulators within the envelope and in between the input window and the output screen, and a high Z glass output window to reduce X-ray backscatter inside and outside of the tube. An X-ray sensitive photographic camera for medical diagnostic use is also disclosed which includes an X-ray sensitive image intensifier means of the proximity type and a reduction type optical system having an effective foral length in excess of 100mm for focusing the emage generated on the output display screen of the image intensifier tube onto a small size but directly viewable photographic film. The parameters of the image intensifier, the optics and the film are specified and linked to each other in a manner which maximizes the image quality for a camera system of this type and at the same time restricts the system speed of the camera to a range of 500 to 5,000 R -1 for the film to achieve a net density of 1.0. (Auth.)

  17. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  18. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home > NEI YouTube Videos > ...

  19. Lunar Core Drive Tubes Summary

    Data.gov (United States)

    National Aeronautics and Space Administration — Contains a brief summary and high resolution imagery from various lunar rock and core drive tubes collected from the Apollo and Luna missions to the moon.

  20. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division ... Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video ...

  1. Conditioning of NEC accelerator tubes

    International Nuclear Information System (INIS)

    Yntema, J.L.

    1979-01-01

    The conditioning process of NEC tubes was investigated by recording the fluctuations observed with a residual gas analyzer for a fixed mass and a simultaneous recording of the current fluctuations in background pressure

  2. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino ... To search for current job openings visit HHS USAJobs Home » NEI YouTube ...

  3. Eddy current tube testing unit

    International Nuclear Information System (INIS)

    Dufayet, J.P.; Duret, G.

    1975-01-01

    The unit described can check a wide variety of tubes in quick succession and its modular design gives it a high degree of versability. Suitably defined working conditions and specific fittings enable most of the faults encountered in the manufacture of a tube to be detected. By appropriate means of selection based on signal amplitude, phase and frequency analyses it is possible to adapt selection criteria to the seriousness of the different categories of defect [fr

  4. Electronics for proportional drift tubes

    International Nuclear Information System (INIS)

    Fremont, G.; Friend, B.; Mess, K.H.; Schmidt-Parzefall, W.; Tarle, J.C.; Verweij, H.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration); Geske, K.; Riege, H.; Schuett, J.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration); Semenov, Y.; CERN-Hamburg-Amsterdam-Rome-Moscow Collaboration)

    1980-01-01

    An electronic system for the read-out of a large number of proportional drift tubes (16,000) has been designed. This system measures deposited charge and drift-time of the charge of a particle traversing a proportional drift tube. A second event can be accepted during the read-out of the system. Up to 40 typical events can be collected and buffered before a data transfer to a computer is necessary. (orig.)

  5. The YouTube reader

    OpenAIRE

    Snickars, Pelle; Vonderau, Patrick

    2009-01-01

    YouTube has come to epitomize the possibilities of digital culture. With more than seventy million unique users a month and approximately eighty million videos online, this brand-name video distribution platform holds the richest repository of popular culture on the Internet. As the fastest growing site in the history of the Web, YouTube promises endless new opportunities for amateur video, political campaigning, entertainment formats, and viral marketing—a clip culture that has seemed to out...

  6. Dermatology on YouTube.

    Science.gov (United States)

    Boyers, Lindsay N; Quest, Tyler; Karimkhani, Chante; Connett, Jessica; Dellavalle, Robert P

    2014-06-15

    YouTube, reaches upwards of six billion users on a monthly basis and is a unique source of information distribution and communication. Although the influence of YouTube on personal health decision-making is well established, this study assessed the type of content and viewership on a broad scope of dermatology related content on YouTube. Select terms (i.e. dermatology, sun protection, skin cancer, skin cancer awareness, and skin conditions) were searched on YouTube. Overall, the results included 100 videos with over 47 million viewers. Advocacy was the most prevalent content type at 24% of the total search results. These 100 videos were "shared" a total of 101,173 times and have driven 6,325 subscriptions to distinct YouTube user pages. Of the total videos, 35% were uploaded by or featured an MD/DO/PhD in dermatology or other specialty/field, 2% FNP/PA, 1% RN, and 62% other. As one of the most trafficked global sites on the Internet, YouTube is a valuable resource for dermatologists, physicians in other specialties, and the general public to share their dermatology-related content and gain subscribers. However, challenges of accessing and determining evidence-based data remain an issue.

  7. Detection of magnetic monopoles in the future neutrino telescope Antares and characterization of the photomultiplier pulse treatment

    International Nuclear Information System (INIS)

    Ricol, J.St.

    2002-10-01

    Grand unified theories (GUT) involve phase transitions in the early universe, that could create topological defects, like magnetic monopoles. Monopoles main characteristics are shown and in particular energy losses and flux limits. High energy neutrino telescopes offer a new opportunity for magnetic monopole search. The study of the photomultiplier pulse treatment by the Antares detector front-end electronics indicates that this one is well adapted to the telescope needs. The pulses detailed analysis has allowed to obtain a time measurement precision lower than 0.6 ns and electronic noise and saturation have no relevant effect on the telescope performances. Relativistic monopoles generate a large amount of light, that leads to an effective area for the Antares detector of about 0.06 km 2 for velocities β mon = 0.6 and 0.35 km 2 for velocities β mon ∼ 1. Monopole track are well reconstructed and the velocity determination is made with an error lower than few percents, which represents a decisive result for the background rejection, caused by high energy muons with a velocity β μ ∼ 1. The very dispersive light emission of monopoles below the Cherenkov limit, 0.6 ∼ mon ≤ 0.74, via the delta-rays produced by ionisation, does not allow an accurate expecting signal and the bad reconstructed muons rejection must be improved. Above the Cherenkov limit, β mon ≥ 0.8, bad reconstructed events can be rejected from the Cherenkov emission parametrisation. A magnetic monopole signal can then clearly be distinguished from background. (author)

  8. A depth-encoding PET detector that uses light sharing and single-ended readout with silicon photomultipliers.

    Science.gov (United States)

    Kuang, Zhonghua; Yang, Qian; Wang, Xiaohui; Fu, Xin; Ren, Ning; Sang, Ziru; Wu, San; Zheng, Yunfei; Zhang, Xianming; Hu, Zhanli; Du, Junwei; Liang, Dong; Liu, Xin; Zheng, Hairong; Yang, Yongfeng

    2018-02-13

    Detectors with depth-encoding capability and good timing resolution are required to develop high-performance whole-body or total-body PET scanners. In this work, depth-encoding PET detectors that use light sharing between two discrete crystals and single-ended readout with silicon photomultipliers (SiPMs) were manufactured and evaluated. The detectors consisted of two unpolished 3  ×  3  ×  20 mm 3 LYSO crystals with different coupling materials between them and were read out by Hamamatsu 3  ×  3 mm 2 SiPMs with one-to-one coupling. The ratio of the energy of one SiPM to the total energy of two SiPMs was used to measure the depth of interaction (DOI). Detectors with different coupling materials in-between the crystals were measured in the singles mode in an effort to obtain detectors that can provide good DOI resolution. The DOI resolution and energy resolution of three types of detector were measured and the timing resolution was measured for the detector with the best DOI and energy resolution. The optimum detector, with 5 mm optical glue, a 9 mm triangular ESR and a 6 mm rectangular ESR in-between the unpolished crystals, provides a DOI resolution of 2.65 mm, an energy resolution of 10.0% and a timing resolution of 427 ps for events of E  >  400 keV. The detectors simultaneously provide good DOI and timing resolution, and show great promise for the development of high-performance whole-body and total-body PET scanners.

  9. A depth-encoding PET detector that uses light sharing and single-ended readout with silicon photomultipliers

    Science.gov (United States)

    Kuang, Zhonghua; Yang, Qian; Wang, Xiaohui; Fu, Xin; Ren, Ning; Sang, Ziru; Wu, San; Zheng, Yunfei; Zhang, Xianming; Hu, Zhanli; Du, Junwei; Liang, Dong; Liu, Xin; Zheng, Hairong; Yang, Yongfeng

    2018-02-01

    Detectors with depth-encoding capability and good timing resolution are required to develop high-performance whole-body or total-body PET scanners. In this work, depth-encoding PET detectors that use light sharing between two discrete crystals and single-ended readout with silicon photomultipliers (SiPMs) were manufactured and evaluated. The detectors consisted of two unpolished 3  ×  3  ×  20 mm3 LYSO crystals with different coupling materials between them and were read out by Hamamatsu 3  ×  3 mm2 SiPMs with one-to-one coupling. The ratio of the energy of one SiPM to the total energy of two SiPMs was used to measure the depth of interaction (DOI). Detectors with different coupling materials in-between the crystals were measured in the singles mode in an effort to obtain detectors that can provide good DOI resolution. The DOI resolution and energy resolution of three types of detector were measured and the timing resolution was measured for the detector with the best DOI and energy resolution. The optimum detector, with 5 mm optical glue, a 9 mm triangular ESR and a 6 mm rectangular ESR in-between the unpolished crystals, provides a DOI resolution of 2.65 mm, an energy resolution of 10.0% and a timing resolution of 427 ps for events of E  >  400 keV. The detectors simultaneously provide good DOI and timing resolution, and show great promise for the development of high-performance whole-body and total-body PET scanners.

  10. Radiation hardness test of un-doped CsI crystals and Silicon Photomultipliers for the Mu2e calorimeter

    Science.gov (United States)

    Baccaro, S.; Cemmi, A.; Cordelli, M.; Diociaiuti, E.; Donghia, R.; Giovannella, S.; Loreti, S.; Miscetti, S.; Pillon, M.; Sarra, I.

    2017-11-01

    The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It should also be fast enough to handle the high rate background and it must operate and survive in a high radiation environment. Simulation studies estimated that, in the hottest regions, each crystal will absorb a dose of 300 Gy and will be exposed to a neutron fluency of 6 × 1011 n/cm2 in 3 years of running. Test of un-doped CsI crystals irradiated up to 900 Gy and to a neutron fluency up to 9 × 1011 n/cm2 have been performed at CALLIOPE and FNG ENEA facilities in Italy. We present our study on the variation of light yield (LY) and longitudinal response uniformity (LRU) of these crystals after irradiation. The ionization dose does not modify LRU while a 20% reduction in LY is observed at 900 Gy. Similarly, the neutron flux causes an acceptable LY deterioration (≤ 15%). A neutron irradiation test on different types of SIPMs (two different array models from Hamamatsu and one from FBK) have also been carried out by measuring the variation of the leakage current and the charge response to an ultraviolet led. We concluded that, in the experiment, we will need to cool down the SIPMs to 0 °C reduce the leakage current to an acceptable level.

  11. Performance evaluation of a sub-millimeter spatial resolution PET detector module using a digital silicon photomultiplier coupled LGSO array

    Energy Technology Data Exchange (ETDEWEB)

    Leem, Hyun Tae [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul (Korea, Republic of); Choi, Yong, E-mail: ychoi@sogang.ac.kr [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul (Korea, Republic of); Kim, Kyu Bom; Lee, Sangwon [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul (Korea, Republic of); Yamamoto, Seiichi [Department of Medical Technology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Yeom, Jung-Yeol, E-mail: jungyeol@korea.ac.kr [School of Biomedical Engineering, Korea University, Seoul (Korea, Republic of)

    2017-02-21

    In positron emission tomography (PET) for breast, brain and small animal imaging, the spatial resolution of a PET detector is crucial to obtain high quality PET images. In this study, a PET detector for sub-millimeter spatial resolution imaging purpose was assembled using 4×4 pixels of a digital silicon photomultiplier (dSiPM, DPC-3200-22-44, Philips) coupled with a 15×15 LGSO array with BaSO{sub 4} reflector, and a 1 mm thick acrylic light guide for light distribution between the dSiPM pixels. The active area of each dSiPM pixel was 3.2×3.9 mm{sup 2} and the size of each LGSO scintillator element was 0.7×0.7×6 mm{sup 3}. In this paper, we experimentally demonstrated the performance of the PET detector by measuring the energy resolution, 2D flood map, peak to valley (P/V) ratio, and coincidence resolving time (CRT). All measurements were performed at a temperature of 10±1 ℃. The average energy resolution was 15.6% (without correcting for saturation effects) at 511 keV and the best CRT was 242±5 ps. The 2D flood map obtained with an energy window of 400–600 keV demonstrated clear identification of all pixels, and the average P/V ratio of the X- and Y-directions were 7.31 and 7.81, respectively. This study demonstrated that the PET detector could be suitable for application in high resolution PET while achieving good timing resolution.

  12. Multi-anode wire straw tube tracker

    International Nuclear Information System (INIS)

    Oh, S.H.; Ebenstein, W.L.; Wang, C.W.

    2011-01-01

    We report on a test of a straw tube detector design having several anode (sense) wires inside a straw tube. The anode wires form a circle inside the tube and are read out independently. This design could solve several shortcomings of the traditional single wire straw tube design such as double hit capability and stereo configuration.

  13. 21 CFR 872.6570 - Impression tube.

    Science.gov (United States)

    2010-04-01

    ... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6570 Impression tube. (a) Identification. An impression tube is a device consisting of a hollow copper tube intended to take an impression of a single tooth... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Impression tube. 872.6570 Section 872.6570 Food...

  14. 27 CFR 41.35 - Cigarette tubes.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Cigarette tubes. 41.35... OF THE TREASURY (CONTINUED) TOBACCO IMPORTATION OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED TOBACCO Taxes Tax Rates § 41.35 Cigarette tubes. Cigarette tubes are taxed at the following rates...

  15. Tubing vs. buckets: a cost comparison

    Science.gov (United States)

    Neil K. Huyler

    1975-01-01

    Equipment investment for tubing-vacuum systems was significantly less than that for bucket systems. Tubing-vacuum systems required about 22 percent less labor input, the major labor input being completed before sap-flow periods. Annual cost of operation was less for tubing-vacuum than the bucket system. Small tubing-vacuum operations showed more profit potential than...

  16. X-ray-sensitive hybrid photon detectors with Be-windows

    CERN Document Server

    D'Ambrosio, Carmelo; Leutz, Heinrich; Puertolas, D; Rosso, Ettore

    2005-01-01

    A 0.3-mm thin YAlO/sub 3/(Ce) scintillating crystal plate of 22 mm diameter was mounted inside an electrostatic-focussed hybrid photomultiplier tube (HPMT). The photocathode was evaporated directly on this scintillating plate opposite to the HPMT-anode. The HPMT was vacuum-sealed with a 1-mm thick Be radiation entrance window. Photoelectron numbers at their peak energies of photoabsorption and energy resolutions were measured between 3.69 and 59.6 keV. The average number of photoelectrons produced per keV radiation energy was determined to be 4.457 phel/keV and the energy resolution at 59.6 keV was 17%. Introducing in the same way such a thin YAlO/sub 3/(Ce) plate inside an imaging silicon pixel array (ISPA) tube would improve its spatial resolution, since it depends on the thickness of the X- ray detector.

  17. Performance characterization of the TRW 35K pulse tube cooler

    International Nuclear Information System (INIS)

    Collins, S.A.; Johnson, D.L.; Smedley, G.T.; Ross, R.G. Jr.

    1996-01-01

    The TRW 35K pulse tube cooler is configured as an integral cooler, with the pulse tube attached perpendicular to a pair of compressors operating into a common compression chamber. The cooler was optimized for 35K operation and has a nominal cooling capacity of 850 mW at 35 K with a cooler input power of 200 W. It also provides 2 W of cooling at 60 K for 90 W of input power. The cooler was extensively characterized by JPL, measuring the thermal performance and the cooler-generated vibration and EMI as a function of piston stroke and offset position. The thermal performance was found to be quite sensitive to the piston offset position. The pulse tube parasitic conduction levels were also measured and shown to have a strong angular dependence relative to gravity. Magnetic shielding studies were performed to examine radiated magnetic emission levels from compressors with and without shielding

  18. Analysis of forming limit in tube hydroforming

    International Nuclear Information System (INIS)

    Kim, Chan Il; Yang, Seung Hang; Kim, Young Suk

    2013-01-01

    The automotive industry has shown increasing interest in tube hydroforming. Despite many automobile structural parts being produced from cylindrical tubes, failures frequently occur during tube hydroforming under improper forming conditions. These problems include wrinkling, buckling, folding back, and bursting. We perform analytical studies to determine forming limits in tube hydroforming and demonstrate how these forming limits are influenced by the loading path. Theoretical results for the forming limits of wrinkling and bursting are compared with experimental results for an aluminum tube.

  19. Physics of magnetic flux tubes

    CERN Document Server

    Ryutova, Margarita

    2015-01-01

    This book is the first account of the physics of magnetic flux tubes from their fundamental properties to collective phenomena in an ensembles of flux tubes. The physics of magnetic flux tubes is absolutely vital for understanding fundamental physical processes in the solar atmosphere shaped and governed by magnetic fields. High-resolution and high cadence observations from recent space and  ground-based instruments taken simultaneously at different heights and temperatures not only show the ubiquity of filamentary structure formation but also allow to study how various events are interconnected by system of magnetic flux tubes. The book covers both theory and observations. Theoretical models presented in analytical and phenomenological forms are tailored for practical applications. These are welded with state-of-the-art observations from early decisive ones to the most recent data that open a new phase-space for exploring the Sun and sun-like stars. Concept of magnetic flux tubes is central to various magn...

  20. Comprehensive modelling for eddy current based pressure tube to calandria tube gap measurements

    Science.gov (United States)

    Klein, Geoffrey

    The separation between the pressure tube (PT) and calandria tube (CT), known as gap, in the CANada Uranium Deuterium (CANDURTM) nuclear reactor fuel channels is monitored using a drive-receive eddy current probe. Gap measurement accuracy is crucial to ensure contact does not occur between the PT and CT, as contact can lead to cracking of the PT. Variation of in-reactor parameters can compromise gap measurement accuracy. Validated models of the eddy current response to changes in gap can be used to help identify parameters whose variations most affect gap measurement accuracy. However, current models are limited, since they assume the PT and CT are infinite parallel conductive plates, thereby, neglecting the potential effects of PT and CT curvature. Finite Element Method (FEM) models of flat-plate geometry, true PT-CT gap probe geometry, and concentric tube geometry were developed to explore how different geometric approximations can model gap response. The concentric tube geometry, where the CT remains axially concentric with the PT, accurately accounted for curvature of the PT and varied gap by changing the radius of the CT, had the possibility of an analytical solution. Comparison between the three FEM models and experimental measurements showed that both curved models gave similar accuracy and were more accurate than the flat-plate geometry model. A Second Order Vector Potential (SOVP) formalism was used to develop a semi-analytical model of the concentric tube geometry. This semi-analytical model was shown to be three to five times more accurate than the analytical flat-plate model, when compared with experimental measurements for varying PT wall thickness and resistivity. Using the semi-analytical concentric model, a sensitivity analysis was performed to evaluate which parameter variations had the largest effect on gap measurements. It was shown that variations in liftoff had the largest effect on predicted gap and were approximately two to three times more

  1. Tube and column agglutination technology for autocontrol testing.

    Science.gov (United States)

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  2. On hydraulics of capillary tubes

    Directory of Open Access Journals (Sweden)

    N.G. Aloyan

    2016-03-01

    Full Text Available The article considers the laws of motion of water in the capillary tubes, taken as a model for flowing well, on the analogical net count device. For capillary tube the lower limit value of flow rate is empirically determined above which the total hydraulic resistance of the capillary is practically constant. The specificity of the phenomenon is that the regime of motion, by a Reynolds number, for a given flow rate still remains laminar. This circumstance can perplex the specialists, so the author invites them to the scientific debate on the subject of study. Obviously, to identify the resulting puzzle it is necessary to conduct a series of experiments using capillaries of different lengths and diameters and with different values of overpressure. The article states that in tubes with very small diameter the preliminary magnitude of capillary rise of water in the presence of flow plays no role and can be neglected.

  3. Patient identification and tube labelling

    DEFF Research Database (Denmark)

    van Dongen-Lases, Edmée C; Cornes, Michael P; Grankvist, Kjell

    2016-01-01

    of phlebotomy procedures with the CLSI H3-A6 guideline was unacceptably low, and that patient identification and tube labelling are amongst the most critical steps in need of immediate attention and improvement. The process of patient identification and tube labelling is an essential safety barrier to prevent......Venous blood sampling (phlebotomy) is the most common invasive procedure performed in patient care. Guidelines on the correct practice of phlebotomy are available, including the H3-A6 guideline issued by the Clinical Laboratory Standards Institute (CLSI). As the quality of practices and procedures...... patient identity mix-up. Therefore, the EFLM Working Group aims to encourage and support worldwide harmonisation of patient identification and tube labelling procedures in order to reduce the risk of preanalytical errors and improve patient safety. With this Position paper we wish to raise awareness...

  4. Drift tubes of Linac 2

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    With the advent of the 800 MeV PS Booster in 1972, the original injector of the PS, a 50 MeV Alvarez-type proton linac, had reached its limits, in terms of intensity and stability. In 1973 one therefore decided to build a new linac (Linac 2), also with a drift-tube Alvarez structure and an energy of 50 MeV. It had a new Cockcroft-Walton preinjector with 750 keV, instead of the previous one with 500 keV. Linac 2 was put into service in 1980. The old Linac 1 was then used for the study of, and later operation with, various types of ions. This picture shows Linac 2 drift-tubes, suspended on stems coming from the top, in contrast to Linac 1, where the drift-tubes stood on stems coming from the bottom.

  5. Miniature X-Ray Tubes

    Science.gov (United States)

    Bearman, Gregory H.

    1995-01-01

    Miniature x-ray tubes proposed for use in portable instruments used to analyze minerals. Electrons from field emitter (instead of thermionic emitter) accelerated to target to generate x-rays. Fabricated from silicon wafers, micromachined field emitters (MFEs) not subject to breakage or restrictions on lifetimes, and tolerate vacuums that filaments cannot. Miniature x-ray tubes very robust, immune to shock and vibration, and permanently sealed with getter for continued pumping. Combined with solid-state x-ray detectors for analysis of x-ray fluorescence.

  6. Working session 3: Tubing integrity

    International Nuclear Information System (INIS)

    Cueto-Felgueroso, C.; Strosnider, J.

    1997-01-01

    Twenty-three individuals representing nine countries (Belgium, Canada, the Czech Republic, France, Japan, the Slovak Republic, Spain, the UK, and the US) participated in the session on tube integrity. These individuals represented utilities, vendors, consultants and regulatory authorities. The major subjects discussed by the group included overall objectives of managing steam generator tube degradation, necessary elements of a steam generator degradation management program, the concept of degradation specific management, structural integrity evaluations, leakage evaluations, and specific degradation mechanisms. The group's discussions on these subjects, including conclusions and recommendations, are summarized in this article

  7. Opposed slant tube diabatic sorber

    Science.gov (United States)

    Erickson, Donald C.

    2004-01-20

    A sorber comprised of at least three concentric coils of tubing contained in a shell with a flow path for liquid sorbent in one direction, a flow path for heat transfer fluid which is in counter-current heat exchange relationship with sorbent flow, a sorbate vapor port in communication with at least one of sorbent inlet or exit ports, wherein each coil is coiled in opposite direction to those coils adjoining it, whereby the opposed slant tube configuration is achieved, with structure for flow modification in the core space inside the innermost coil.

  8. YouTube and Facebook

    DEFF Research Database (Denmark)

    Robertson, Scott P.; Vatrapu, Ravi; Medina, Richard

    This paper examines the links to YouTube from the Facebook “walls” of Barack Obama, Hillary Clinton, and John McCain over two years prior to the 2008 U.S. Presidential election. User-generated linkage patterns show how participants in these politically-related social networking dialogues used...... online video to make their points. We show a strong integration of the Web 2.0 and new media technologies of social networking and online video. We argue that political discussion in social networking environments can no longer be viewed as primarily textual, and that neither Facebook nor YouTube can...

  9. Energy resolution and light yield non-proportionality of ZnSe Te scintillator studied by large area avalanche photodiodes and photomultipliers

    CERN Document Server

    Balcerzyk, M; Moszynski, M; Kapusta, M; Szawlowski, M

    2002-01-01

    The ZnSe : Te scintillator has been studied by means of a photomultiplier with an extended bialkali photocathode, a large area avalanche photodiode (LAAPD) and a PIN photodiode. The light output was determined to be 28 300+-1700 photons/MeV. Results indicate good proportionality for light output versus gamma-ray energy. Measurements of the 662 keV gamma-ray energy spectrum recorded using a LAAPD resulted in an energy resolution of 5.4+-0.3%. Based on these results, an intrinsic energy resolution of 3.3+-0.7% has been calculated.

  10. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...... pump as mentioned above, thereby acting to generate a fluid flow through the tube upon repeated deformation of the tube between the two valve members. The pump element may comprise a connecting part for coupling to another tube and may comprise a sealing part establishing a fluid tight connection...

  11. Investigations on the limits of uncertainty of gas density measurements with vibrating tube densimeters

    Science.gov (United States)

    Laznickova, Romana; Huemer, Hans

    1998-05-01

    The aim of this work was to examine the scope and limitations of gas density measurements with vibrating tube densimeters, especially their limits of measurement uncertainty. For this purpose, equipment was designed with glass and stainless steel vibrating tubes. The stability and sensitivity of the equipment were tested by measuring empty tubes (vacuum); the reproducibility of gas density measurements was examined with argon and methane. A calibration equation was derived from measurements with evacuated tubes, liquid water, argon and methane by means of the Wagner equation optimization method. With the gases helium, nitrogen, carbon dioxide, butane, tetrafluoromethane and sulphur hexafluoride the uncertainty of gas density measurements was tested. The measurements were performed in the range 30-0957-0233/9/5/001/img1 C in the pressure range 0-2.7 MPa. The uncertainty of gas density measurements with vibrating tubes is in the range of hundredths of kg 0957-0233/9/5/001/img2; the sensitivity of the equipment to density changes is higher by at least one order of magnitude. The primary reason for the great difference between the sensitivity and the uncertainty of measurements is the inadequate pressure stability of the vibrating tubes. In order to perform gas density measurements of higher quality (for example for scientific purposes) it would be necessary to increase the stability of the vibrating tubes at changing pressure loads by modifying their construction and/or materials.

  12. Study on antioxidant experiment on forged steel tube sheet and tube hole for steam generator

    International Nuclear Information System (INIS)

    Zong Hai; Wang Detai; Ding Yang

    2012-01-01

    Antioxidant experiment on forged steel tube sheet and tube hole for steam generator was studied and the influence of different simulated heat treatments on the antioxidant performance of tube sheet and tube hole was made. The influence of different antioxidant methods on the size of tube hole was drawn. Furthermore, the change of size and weight of 18MnD5 forged steel tube sheet on the condition of different simulated heat treatments was also studied. The analytical results have proved reference information for the use of 18MnD5 material and for key processes of processing tube hole and wearing and expanding U-style tube. (authors)

  13. Mechanical support for straw tubes

    International Nuclear Information System (INIS)

    Joestlein, H.

    1990-01-01

    A design is proposed for mounting a large number of straw tubes to form an SSC central tracking chamber. The assembly is precise and of very low mass. The fabrication is modular and can be carried out with a minimum of tooling and instrumentation. Testing of modules is possible prior to the final assembly. 4 figs

  14. OurTube / David Talbot

    Index Scriptorium Estoniae

    Talbot, David

    2009-01-01

    USA California Ülikooli töötajate Abram Stern'i ja Michael Dale'i poolt 2005. a. algatatud USA kongressis peetud kõnede videoremiksidest ja nende poolt loodud veebisaidist Metavid.org. Ka YouTube keskkonnast ja wikipedia katsetustest muuta oma keskkond multimeedialisemaks

  15. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  16. Working session 1: Tubing degradation

    International Nuclear Information System (INIS)

    Kharshafdjian, G.; Turluer, G.

    1997-01-01

    A general introductory overview of the purpose of the group and the general subject area of SG tubing degradation was given by the facilitator. The purpose of the session was described as to open-quotes develop conclusions and proposals on regulatory and technical needs required to deal with the issues of SG tubing degradation.close quotes Types, locations and characteristics of tubing degradation in steam generators were briefly reviewed. The well-known synergistic effects of materials, environment, and stress and strain/strain rate, subsequently referred to by the acronym open-quotes MESSclose quotes by some of the group members, were noted. The element of time (i.e., evolution of these variables with time) was emphasized. It was also suggested that the group might want to consider the related topics of inspection capabilities, operational variables, degradation remedies, and validity of test data, and some background information in these areas was provided. The presentation given by Peter Millet during the Plenary Session was reviewed; Specifically, the chemical aspects and the degradation from the secondary side of the steam generator were noted. The main issues discussed during the October 1995 EPRI meeting on secondary side corrosion were reported, and a listing of the potential SG tube degradations was provided and discussed

  17. Case of nasogastric tube dysfunction.

    Science.gov (United States)

    Rainer, Florian; Prenner, Guenther; Binder, Lukas Peter; Fickert, Peter; Plank, Johannes

    2018-01-05

    An elderly female patient was admitted to intensive care for prolonged vasopressor therapy and mechanical ventilation after cardiac arrest and acute percutaneous coronary intervention. Antiplatelet, thyroid hormone replacement and statin therapies were administered through a 14-French nasogastric tube (Nestlé Health Science) and enteral feeding was initiated. Correct position of the nasogastric tube was confirmed radiologically. On the seventh day in the intensive care, our patient was seen to regurgitate soft crumbs into her mouth. The blocked nasogastric tube was removed, but attempts to reinsert another tube failed.Upper GI endoscopy revealed an obstruction of the oesophagus with a milky-yellowish caseous substance 20 cm from the incisors (figure 1). The proximal part of the mass showed a central hole and ring-shaped layers resembling the cut face of a tree trunk.gutjnl;gutjnl-2017-315619v1/F1F1F1Figure 1Obstruction of the oesophagus with a milky-yellowish caseous substance. What caused the obstruction?How should we manage such a problem? © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Kundt's Tube Experiment Using Smartphones

    Science.gov (United States)

    Parolin, Sara Orsola; Pezzi, Giovanni

    2015-01-01

    This article deals with a modern version of Kundt's tube experiment. Using economic instruments and a couple of smartphones, it is possible to "see" nodes and antinodes of standing acoustic waves in a column of vibrating air and to measure the speed of sound.

  19. Steam generator tube integrity program

    International Nuclear Information System (INIS)

    Diercks, D.R.; Shack, W.J.

    1996-01-01

    The degradation of steam generator tubes in pressurized water nuclear reactors continues to be a serious problem, and the US Nuclear Regulatory Commission (NRC) is developing a performance-based rule and regulatory guide for steam generator tube integrity. To support the evaluation of industry-proposed implementation of these performance-based criteria, the NRC is sponsoring a new research program at Argonne National Laboratory on steam generator tubing degradation. The objective of the new program is to provide the necessary experimental data and predictive correlations and models that will permit the NRC to independently evaluate the integrity of steam generator tubes. The technical work in the program is divided into four tasks, (1) assessment of inspection reliability, (2) research on in-service inspection technology, (3) research on degradation modes and integrity, and (4) development of methodology and technical assessments for current and emerging regulatory issues. The objectives of and planned research activities under each of these four tasks are described here. (orig.)

  20. Tube in shell heat exchangers

    International Nuclear Information System (INIS)

    Hayden, O.; Willby, C.R.; Sheward, G.E.; Ormrod, D.T.; Firth, G.F.

    1980-01-01

    An improved tube-in-shell heat exchanger to be used between liquid metal and water is described for use in the liquid metal coolant system of fast breeder reactors. It is stated that this design is less prone to failures which could result in sodium water reactions than previous exchangers. (UK)

  1. Tubing with high corrosion resistance

    Science.gov (United States)

    Ioffe, A. V.; Tetyueva, T. V.; Vyboyshchik, M. A.; Trifonova, E. A.; Lutsenko, E. S.

    2010-07-01

    The optimum chemical composition and the regime for heat treatment of heat-resistant steel 15Kh5M are determined for the production of tubing with strength of group L80 (API 5CT) and high cold resistance and resistance to carbon dioxide and sulfurated hydrogen corrosion at low alloying additives of chromium and molybdenum.

  2. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube ...

  3. Welding the CNGS decay tube

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    3.6 km of welds were required for the 1 km long CERN Neutrinos to Gran Sasso (CNGS) decay tube, in which particles produced in the collision with a proton and a graphite target will decay into muons and muon neutrinos. Four highly skilled welders performed this delicate task.

  4. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » ...

  5. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Science.gov (United States)

    2010-04-01

    ... intubation, feeding tube, gastroenterostomy tube, Levine tube, nasogastric tube, single lumen tube with... § 876.9. (2) Class I (general controls) for the dissolvable nasogastric feed tube guide for the nasogastric tube. The class I device is exempt from the premarket notification procedures in subpart E of part...

  6. Thermoluminescence dosimeter reader

    International Nuclear Information System (INIS)

    Robertson, M.E.A.; Marshall, J.; Brabants, J.A.P.; Davies, M.E.

    1975-01-01

    An electric circuit arrangement is described including a photomultiplier tube and a high voltage source therefor also includes a feedback loop from the output of the tube to the high voltage source, and loop providing automatic gain stabilization for the tube. The arrangement is used in a dosimeter reader to provide sensitivity correction for the reader each time the reader is to be used

  7. Schizophrenia on YouTube.

    Science.gov (United States)

    Nour, Matthew M; Nour, Murraih H; Tsatalou, Olga-Maria; Barrera, Alvaro

    2017-01-01

    YouTube ( www.youtube.com ) is the most popular video-sharing Web site on the Internet and is used by medical students as a source of information regarding mental health conditions, including schizophrenia. The accuracy and educational utility of schizophrenia presentations on YouTube are unknown. The purpose of this study was to analyze the accuracy of depictions of psychosis in the context of a diagnosis of schizophrenia (referred to in this article as "acute schizophrenia") on YouTube and to assess the utility of these videos as educational tools for teaching medical students to recognize the clinical features of acute schizophrenia. YouTube was searched for videos purporting to show acute schizophrenia. Eligible videos were independently rated by two consultant psychiatrists on two separate occasions 22 days apart for diagnostic accuracy, psychopathology, and educational utility. Videos (N=4,200) were assessed against predefined inclusion and exclusion criteria. The majority were not eligible for further analysis, mostly because they did not claim to show a patient with schizophrenia (74%) or contained duplicated content (11%). Of 35 videos that met the eligibility and adequacy criteria, only 12 accurately depicted acute schizophrenia. Accurate videos were characterized by persecutory delusions (83%), inappropriate affect (75%), and negative symptoms (83%). Despite the fact that 83% of accurate videos were deemed to have good educational utility compared with 15% of inaccurate videos, accurate and inaccurate videos had similar view counts (290,048 versus 186,124). Schizophrenia presentations on YouTube offer a distorted picture of the condition.

  8. Preparation of metallic uranium tubes

    International Nuclear Information System (INIS)

    Lerouge, G.; Decours, J.

    1964-01-01

    The production furnace is an induction heated vacuum furnace having a capacity at the moment of 250 kg. Previously the crucible was heated by the inductor, the mould being outside the inductor. The tubes thus produced contained cavities, the alloy structure was fine; this was cold-mould casting, At the moment the top of the moulds are pre-heated, this is the so called hot-mould casting. This method has the advantage of eliminating the cavities but leads to a less fine microstructure. The alloy used for the 18 x 40 mm and 23 x 43 mm tubes is U-Mo (1.1 per cent). Since the moulds are now heated at the top, the solidification of the metal is very slow in this zone leading to a pronounced γ grain, whereas towards the base the faster cooling leads to a smaller γ grain. The γ structure depends essentially on the solidification rate and on the time spent in this zone. In order to obtain a fine and homogeneous grain along the whole length of the tube, a controlled cooling treatment is effected. It consists in heating the uranium tubes in the γ place and then in cooling them at a rate of between 20 and 50 deg C/mm down to 400 deg C. The 77 x 95 mm and 54 x 70 mm annular elements are at the moment being produced for research purposes. Their preparation is similar to that of 18 x 40 mm and 23 x 43 mm elements. The 77 x 95 mm tubes are at the moment made from U-Cr alloy (0.1 per cent); because of their size, their preparation is carried out in 600 mm diameter furnaces. (authors) [fr

  9. Improving the calandria tubes for CANDU reactors

    International Nuclear Information System (INIS)

    Coleman, C.E.; Fong, R.W.L.; Doubt, G.L.

    1997-01-01

    CANDU calandria tubes are made from annealed Zircaloy-2 sheet formed into a cylinder and welded along its length to make the tube. The current calandria tubes have given exemplary service for many years. With more stringent regulations and the need to accommodate warm cooling water in tropical countries, we started a development program to increase the margins for failure during postulated accidents. These improvements involve increasing the tube strength and optimising the heat-transfer from an excessively hot fuel channel to the cool moderator. If the postulated accident involves a pressure tube break, it would be desirable if the calandria tube withstood the full pressure of the heat-transport system. The weakest link in current calandria tubes is the weld. Thickening the weld can increase the strength by 20% while seamless tubes can be 45% stronger than current tubes. The latter tubes can hold full system pressure for many hours without failure. If during the postulated accident the fuel and pressure tube become excessively hot but do not touch the calandria tube, the radiant heat loss must be maximised. Current calandria tubes have an absorptivity (emissivity) of about 0.2. To protect the fuel and the fuel channel we have devised a finish to the inside surface of the calandria tube that increases the emissivity to 0.7. If during the postulated accident the hot pressure tube touches the cool calandria tube, the contact conductance and the critical heat flux must be optimised to ensure nucleate boiling of the moderator at the outside surface of the calandria tube and therefore efficient exploitation of the moderator as a heat sink. In laboratory tests small ridges on the inside surface and roughening of the outside surface have been shown to increase the margins against failure and increase the possible moderator temperatures thus providing the opportunity to decrease the cost of the moderator heat-exchange system and remove restrictions on reactor operation in

  10. A case of a 'lost' nasogastric tube.

    Science.gov (United States)

    Sankar, V; Shakeel, M; Keh, S; Ah-See, K W

    2012-12-01

    To present the case of a 'lost' nasogastric tube and to highlight the importance of imaging and/or chest X-ray after nasogastric tube insertion, especially in unreliable patients. A 50-year-old man, undergoing radiotherapy treatment for squamous cell carcinoma of the tongue base, was admitted for pain control and nasogastric tube feeding. This patient required multiple nasogastric tubes over a two-week period. The patient repeatedly denied pulling the nasogastric tube out and we were unable to establish the exact mode of nasogastric tube removal. On one such occasion another tube was inserted and a check X-ray showed two feeding tubes; the latest one was lying in the left main bronchus and the old nasogastric tube was observed in the oesophagus, with its upper end jutting above the hypopharynx. It was apparent that the patient had somehow cut the tube and swallowed it. This case not only illustrates the importance of flexible nasendoscopy and/or chest X-ray for checking the position of the nasogastric tube, but also highlights that some patients are not tolerant of nasogastric tubes. The use of nasogastric tubes should be avoided in these patients to prevent any self-inflicted injury.

  11. [Tracheal intubation with Parker Flex-Tip tubes assisted by tube-guiding devices].

    Science.gov (United States)

    Mizuno, Ju; Morita, Shigeho; Suzuki, Maya; Arita, Hideko; Hanaoka, Kazuo

    2010-04-01

    In tracheal intubation assisted by tube-guiding devices passing through the tube, such as fiberoptic scopes, bougies, tracheal tube exchange catheters, and light wands, passage of the tube-guiding device, by itself, is often easy. But advancing a tracheal tube with a conventional distal tip over these tube-guiding devices is frequently difficult or impossible, because its rigid, side-beveled tip frequently catches on anatomical features of the airway. A novel tracheal tube, the Parker Flex-Tip tube (Parker Medical, Colorado, USA) has a centered, curved, tapered and flexible distal tip that passes through the airway faster and easier than conventional tracheal tubes. As it is advanced along a tube-guiding device, the tip of the Parker tube travels along the midline of the airway, without the gap that usually exists between the distal edge of a conventional tracheal tube and the tube-guiding device. The gapless, midline travel of the Parker tube leads to a greater incidence of first-attempt intubation success with tube-guiding devices, because there is less risk of tube tip hang-ups on the arytenoids and the vocal cords. Clinically, use of the Parker tube is helpful for oral and nasal intubations, especially in patients with difficult airways.

  12. Outcomes of Infants with Home Tube Feeding: Comparing Nasogastric Versus Gastrostomy Tubes

    Science.gov (United States)

    Khalil, Syed Tariq; Uhing, Michael R.; Duesing, Lori; Visotcky, Alexis; Tarima, Sergey; Nghiem-Rao, T. Hang

    2017-01-01

    Background Determine the tube-related complications and feeding outcomes of infants discharged home from the NICU with nasogastric (NG) tube feeding or gastrostomy (G-tube) feeding. Material & Methods We performed a chart review of 335 infants discharged from our NICU with home NG tube or G-tube feeding between January 2009 – December 2013. The primary outcome was the incidence of feeding tube-related complications requiring emergency department (ED) visits, hospitalizations, or deaths. Secondary outcome was feeding status at 6 months post-discharge. Univariate and multivariate analyses were conducted. Results There were 322 infants discharged with home enteral tube feeding, 84 NG tube and 238 G-tube, with available out-patient data for the 6 month post-discharge period. A total of 115 ED visits, 28 hospitalizations, and 2 deaths were due to a tube-related complication. The incidence of tube-related complications requiring an ED visit was significantly higher in the G-tube group compared to the NG tube group (33.6% vs 9.5%, p tube related complication. By 6 months post-discharge, full oral feeding was achieved in 71.4% of infants in the NG tube group compared to 19.3% in the G-tube group (p tube and percentage of oral feeding at discharge were significantly associated with continued tube feeding at 6 months post-discharge. Conclusion Home NG tube feeding is associated with fewer ED visits for tube-related complications compared to home G-tube feeding. There may be some infants who could benefit from a trial home NG tube feeding. PMID:27647478

  13. Outcomes of Infants With Home Tube Feeding: Comparing Nasogastric vs Gastrostomy Tubes.

    Science.gov (United States)

    Khalil, Syed Tariq; Uhing, Michael R; Duesing, Lori; Visotcky, Alexis; Tarima, Sergey; Nghiem-Rao, T Hang

    2017-11-01

    The aim of this study was to determine the tube-related complications and feeding outcomes of infants discharged home from the neonatal intensive care unit (NICU) with nasogastric (NG) tube feeding or gastrostomy (G-tube) feeding. We performed a chart review of 335 infants discharged from our NICU with home NG tube or G-tube feeding between January 2009 and December 2013. The primary outcome was the incidence of feeding tube-related complications requiring emergency department (ED) visits, hospitalizations, or deaths. Secondary outcome was feeding status at 6 months postdischarge. Univariate and multivariate analyses were conducted. There were 322 infants discharged with home enteral tube feeding (NG tube, n = 84; G-tube, n = 238), with available outpatient data for the 6-month postdischarge period. A total of 115 ED visits, 28 hospitalizations, and 2 deaths were due to a tube-related complication. The incidence of tube-related complications requiring an ED visit was significantly higher in the G-tube group compared with the NG tube group (33.6% vs 9.5%, P tube-related complication. By 6 months postdischarge, full oral feeding was achieved in 71.4% of infants in the NG tube group compared with 19.3% in the G-tube group ( P tube and percentage of oral feeding at discharge were significantly associated with continued tube feeding at 6 months postdischarge. Home NG tube feeding is associated with fewer ED visits for tube-related complications compared with home G-tube feeding. Some infants could benefit from a trial home NG tube feeding.

  14. In service inspection for steam generator tubes

    International Nuclear Information System (INIS)

    Comby, R.; Eyrolles, Ph.

    1988-01-01

    In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations [fr

  15. X-ray tube current control

    International Nuclear Information System (INIS)

    Dupuis, W.A.; Resnick, T.A.

    1982-01-01

    A closed loop feedback system for controlling the current output of an x-ray tube. The system has circuitry for improving the transient response and stability of the x-ray tube current over a substantial nonlinear portion of the tube current production characteristic. The system includes a reference generator for applying adjustable step function reference signals representing desired tube currents. The system also includes means for instantaneous sensing of actual tube current. An error detector compares the value of actual and reference tube current and produces an error signal as a function of their difference. The system feedback loop includes amplification circuitry for controlling x-ray tube filament dc voltage to regulate tube current as a function of the error signal value. The system also includes compensation circuitry, between the reference generator and the amplification circuitry, to vary the loop gain of the feedback control system as a function of the reference magnitude

  16. The accessory fallopian tube: A rare anomaly

    Directory of Open Access Journals (Sweden)

    Kusum R Gandhi

    2012-01-01

    Full Text Available This paper presents a rare anatomical variation in the form of accessory fallopian tube on right side. The duplication of fallopian tube was observed in a 34-year-old female during routine undergraduate dissection in our department. Fallopian tube is the part of uterus that carries the ovum from the ovary to the uterus. Accessory fallopian tube is the congenital anomaly attached to the ampullary part of main tube. This accessory tube is common site of pyosalpinx, hydrosalpinx, cystic swelling and torsion. The ovum released by the ovary may also be captured by the blind accessory tube leading to infertility or ectopic pregnancy. Hence, all patients of infertility or pelvic inflammatory disease should be screened to rule out the presence of accessory fallopian tube and if encountered should be removed.

  17. Chemical cleaning specification: few tube test model

    International Nuclear Information System (INIS)

    Hampton, L.V.; Simpson, J.L.

    1979-09-01

    The specification is for the waterside chemical cleaning of the 2 1/4 Cr - 1 Mo steel steam generator tubes. It describes the reagents and conditions for post-chemical cleaning passivation of the evaporator tubes

  18. Prestressed Carbon Fiber Composite Overwrapped Gun Tube

    National Research Council Canada - National Science Library

    Littlefield, Andrew; Hyland, Edward

    2006-01-01

    .... Using composite materials not only directly removes weight from the gun tube but, by better balancing the tube, allows the use of smaller drive systems, thus further enhancing the system weight loss...

  19. [Ultrasound evaluation of the nasogastric tube position in prehospital].

    Science.gov (United States)

    Brun, P-M; Chenaitia, H; Bessereau, J; Leyral, J; Barberis, C; Pradel-Thierry, A-L; Stephan, J; Benner, P; Querellou, E; Topin, F

    2012-05-01

    To assess the feasibility and actual performance of ultrasound control in verification of the correct positioning of a nasogastric tube in pre-hospital settings. Prospective, observational, single-centre study. Correct positioning of nasogastric tubes in patients intubated in a pre-hospital setting was verified by ultrasound and routinely compared with the results of two pre-hospital tests, namely a test involving insufflation of air through a syringe coupled with epigastric auscultation and a test involving aspiration of gastric fluid with a syringe. Routine x-ray control was carried out and compared with the pre-hospital results. Ninety-six patients were included. Mean age was 52 years (median: 53.5 years, SD: 23 years). In 83% of the patients (n=80), the nasogastric tube was located by ultrasound immediately during the insertion procedure. The mean times to ultrasound confirmation of correct positioning of the nasogastric tube were 7s (median: 2s; SD: 16s) and 19s for the syringe tests (median 19s, SD: 5s). Eight ultrasound control tests were negative. Location coupled with insufflation of air through a syringe allowed detection of the nasogastric tube in the stomach but without providing confirmation of the actual gastric position. The pre-hospital ultrasound results were confirmed by subsequent radiological controls at the hospital. The ultrasound test performed in our study to verify correct positioning of a nasogastric tube is feasible in a pre-hospital setting. This technique is rapid and non-irradiating and is more sensitive and specific than the syringe tests commonly used in pre-hospital settings, and it may be performed in place of the latter tests. Copyright © 2012 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  20. Ceramic vacuum tubes for geothermal well logging

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, R.D.

    1977-01-01

    Useful design data acquired in the evaluation of ceramic vacuum tubes for the development of a 500/sup 0/C instrumentation amplifier are presented. The general requirements for ceramic vacuum tubes are discussed for application to the development of high temperature well logs. Commercially available tubes are described and future contract activities that specifically relate to ceramic vacuum tubes are detailed. Supplemental data are presented in the appendix.

  1. Thermal stresses in composite tubes using complementary virtual work

    Science.gov (United States)

    Hyer, M. W.; Cooper, D. E.

    1988-01-01

    This paper addresses the computation of thermally induced stresses in layered, fiber-reinforced composite tubes subjected to a circumferential gradient. The paper focuses on using the principle of complementary virtual work, in conjunction with a Ritz approximation to the stress field, to study the influence on the predicted stresses of including temperature-dependent material properties. Results indicate that the computed values of stress are sensitive to the temperature dependence of the matrix-direction compliance and matrix-direction thermal expansion in the plane of the lamina. There is less sensitivity to the temperature dependence of the other material properties.

  2. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing

  3. Spring/dimple instrument tube restraint

    Science.gov (United States)

    DeMario, E.E.; Lawson, C.N.

    1993-11-23

    A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs. 7 figures.

  4. Manual tube-to-tubesheet welding torch

    Science.gov (United States)

    Kiefer, Joseph H.; Smith, Danny J.

    1982-01-01

    A welding torch made of a high temperature plastic which fits over a tube intermediate the ends thereof for welding the juncture between the tube and the back side of a tube plate and has a ballooned end in which an electrode, filler wire guide, fiber optic bundle, and blanketing gas duct are disposed.

  5. Heat exchanger with a removable tube section

    Science.gov (United States)

    Wolowodiuk, W.; Anelli, J.

    1975-07-29

    A heat exchanger is described in which the tube sheet is secured against primary liquid pressure, but which allows for easy removal of the tube section. The tube section is supported by a flange which is secured by a number of shear blocks, each of which extends into a slot which is immovable with respect to the outer shell of the heat exchanger. (auth)

  6. The Fuge Tube Diode Array Spectrophotometer

    Science.gov (United States)

    Arneson, B. T.; Long, S. R.; Stewart, K. K.; Lagowski, J. J.

    2008-01-01

    We present the details for adapting a diode array UV-vis spectrophotometer to incorporate the use of polypropylene microcentrifuge tubes--fuge tubes--as cuvettes. Optical data are presented validating that the polyethylene fuge tubes are equivalent to the standard square cross section polystyrene or glass cuvettes generally used in…

  7. Sensitivity analysis

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003741.htm Sensitivity analysis To use the sharing features on this page, please enable JavaScript. Sensitivity analysis determines the effectiveness of antibiotics against microorganisms (germs) ...

  8. Numerical and experimental study of an annular pulse tube used in the pulse tube cooler

    Science.gov (United States)

    Pang, Xiaomin; Chen, Yanyan; Wang, Xiaotao; Dai, Wei; Luo, Ercang

    2017-12-01

    Multi-stage pulse tube coolers normally use a U-type configuration. For compactness, it is attractive to build a completely co-axial multi-stage pulse tube cooler. In this way, an annular shape pulse tube is inevitable. Although there are a few reports about previous annular pulse tubes, a detailed study and comparison with a circular pulse tube is lacking. In this paper, a numeric model based on CFD software is carried out to compare the annular pulse tube and circular pulse tube used in a single stage in-line type pulse tube cooler with about 10 W of cooling power at 77 K. The length and cross sectional area of the two pulse tubes are kept the same. Simulation results show that the enthalpy flow in the annular pulse tube is lower by 1.6 W (about 11% of the enthalpy flow) compared to that in circular pulse tube. Flow and temperature distribution characteristics are also analyzed in detail. Experiments are then conducted for comparison with an in-line type pulse tube cooler. With the same acoustic power input, the pulse tube cooler with a circular pulse tube obtains 7.88 W of cooling power at 77 K, while using an annular pulse tube leads to a cooling power of 7.01 W, a decrease of 0.9 W (11.4%) on the cooling performance. The study sets the basis for building a completely co-axial two-stage pulse tube cooler.

  9. Morphomechanics: transforming tubes into organs.

    Science.gov (United States)

    Taber, Larry A

    2014-08-01

    After decades focusing on the molecular and genetic aspects of organogenesis, researchers are showing renewed interest in the physical mechanisms that create organs. This review deals with the mechanical processes involved in constructing the heart and brain, concentrating primarily on cardiac looping, shaping of the primitive brain tube, and folding of the cerebral cortex. Recent studies suggest that differential growth drives large-scale shape changes in all three problems, causing the heart and brain tubes to bend and the cerebral cortex to buckle. Relatively local changes in form involve other mechanisms such as differential contraction. Understanding the mechanics of organogenesis is central to determining the link between genetics and the biophysical creation of form and structure. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Microwave discharges in capillary tubes

    International Nuclear Information System (INIS)

    Dervisevic, Emil

    1984-01-01

    This research thesis aims at being a contribution to the study of microwave discharge by a surface wave, and more precisely focusses on the discharge in capillary tubes filled with argon. The author first present theoretical models which describe, on the one hand, the propagation of the surface wave along the plasma column, and, on the other hand, longitudinal and radial profiles of the main discharge characteristics. The second part addresses the study of the influence of parameters (gas pressure and tube radius) on discharge operation and characteristics. Laws of similitude as well as empirical relationships between argon I and argon II emission line intensities, electron density, and electric field in the plasma have been established [fr

  11. Ionization tube simmer current circuit

    Science.gov (United States)

    Steinkraus, R.F. Jr.

    1994-12-13

    A highly efficient flash lamp simmer current circuit utilizes a fifty percent duty cycle square wave pulse generator to pass a current over a current limiting inductor to a full wave rectifier. The DC output of the rectifier is then passed over a voltage smoothing capacitor through a reverse current blocking diode to a flash lamp tube to sustain ionization in the tube between discharges via a small simmer current. An alternate embodiment of the circuit combines the pulse generator and inductor in the form of an FET off line square wave generator with an impedance limited step up output transformer which is then applied to the full wave rectifier as before to yield a similar simmer current. 6 figures.

  12. ATLAS Muon Drift Tube Electronics

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Y [KEK, High Energy Accelerator Research Organisation, Tsukuba (Japan); Ball, B; Chapman, J W; Dai, T; Ferretti, C; Gregory, J [University of Michigan, Department of Physics, Ann Arbor, MI (United States); Beretta, M [INFN Laboratori Nazionali di Frascati, Frascati (Italy); Boterenbrood, H; Jansweijer, P P M [Nikhef National Institute for Subatomic Physics, Amsterdam (Netherlands); Brandenburg, G W; Fries, T; Costa, J Guimaraes da; Harder, S; Huth, J [Harvard University, Laboratory for Particle Physics and Cosmology, Cambridge, MA (United States); Ceradini, F [INFN Roma Tre and Universita Roma Tre, Dipartimento di Fisica, Roma (Italy); Hazen, E [Boston University, Physics Department, Boston, MA (United States); Kirsch, L E [Brandeis University, Department of Physics, Waltham, MA (United States); Koenig, A C [Radboud University Nijmegen/Nikhef, Dept. of Exp. High Energy Physics, Nijmegen (Netherlands); Lanza, A [INFN Pavia, Pavia (Italy); Mikenberg, G [Weizmann Institute of Science, Department of Particle Physics, Rehovot (Israel)], E-mail: brandenburg@physics.harvard.edu (and others)

    2008-09-15

    This paper describes the electronics used for the ATLAS monitored drift tube (MDT) chambers. These chambers are the main component of the precision tracking system in the ATLAS muon spectrometer. The MDT detector system consists of 1,150 chambers containing a total of 354,000 drift tubes. It is capable of measuring the sagitta of muon tracks to an accuracy of 60 {mu}m, which corresponds to a momentum accuracy of about 10% at p{sub T}= 1 TeV. The design and performance of the MDT readout electronics as well as the electronics for controlling, monitoring and powering the detector will be discussed. These electronics have been extensively tested under simulated running conditions and have undergone radiation testing certifying them for more than 10 years of LHC operation. They are now installed on the ATLAS detector and are operating during cosmic ray commissioning runs.

  13. ATLAS Muon Drift Tube Electronics

    CERN Document Server

    Arai, Y; Beretta, M; Boterenbrood, H; Brandenburg, G W; Ceradini, F; Chapman, J W; Dai, T; Ferretti, C; Fries, T; Gregory, J; Guimarães da Costa, J; Harder, S; Hazen, E; Huth, J; Jansweijer, P P M; Kirsch, L E; König, A C; Lanza, A; Mikenberg, G; Oliver, J; Posch, C; Richter, R; Riegler, W; Spiriti, E; Taylor, F E; Vermeulen, J; Wadsworth, B; Wijnen, T A M

    2008-01-01

    This paper describes the electronics used for the ATLAS monitored drift tube (MDT) chambers. These chambers are the main component of the precision tracking system in the ATLAS muon spectrometer. The MDT detector system consists of 1,150 chambers containing a total of 354,000 drift tubes. It is capable of measuring the sagitta of muon tracks to an accuracy of 60 microns, which corresponds to a momentum accuracy of about 10% at pT = 1 TeV. The design and performance of the MDT readout electronics as well as the electronics for controlling, monitoring and powering the detector will be discussed. These electronics have been extensively tested under simulated running conditions and have undergone radiation testing certifying them for more than 10 years of LHC operation. They are now installed on the ATLAS detector and are operating during cosmic ray commissioning runs.

  14. Origami interleaved tube cellular materials

    International Nuclear Information System (INIS)

    Cheung, Kenneth C; Tachi, Tomohiro; Calisch, Sam; Miura, Koryo

    2014-01-01

    A novel origami cellular material based on a deployable cellular origami structure is described. The structure is bi-directionally flat-foldable in two orthogonal (x and y) directions and is relatively stiff in the third orthogonal (z) direction. While such mechanical orthotropicity is well known in cellular materials with extruded two dimensional geometry, the interleaved tube geometry presented here consists of two orthogonal axes of interleaved tubes with high interfacial surface area and relative volume that changes with fold-state. In addition, the foldability still allows for fabrication by a flat lamination process, similar to methods used for conventional expanded two dimensional cellular materials. This article presents the geometric characteristics of the structure together with corresponding kinematic and mechanical modeling, explaining the orthotropic elastic behavior of the structure with classical dimensional scaling analysis. (paper)

  15. Design and construction of tetrode tube modulator for high power electron accelerator

    Directory of Open Access Journals (Sweden)

    A M Poursaleh

    2015-09-01

    Full Text Available In this paper, a high power tetrode tube (TH781-200kW, cw modulator is designed and implemented. This modulator is used for a part of RF system of the first Iranian high power electron accelerator project with similar structure to Rhodotron accelerator. Regarding to the level of sensitive and importance of TH781 tube the modulator system designed with high accuracy. So beside of power supplies design the control circuits for protection of the tube have been considered. The results of test and operation of this system that have been constructed in Iran for fist time is very satisfactory

  16. X-ray tube target

    International Nuclear Information System (INIS)

    Weber, R.G.

    1980-01-01

    A target with an improved heat emissive surface for use in a rotating anode type x-ray tube is described. The target consists of a body having a first surface portion made of x-ray emissive material and a second surface portion made of a heat emissive material comprising at least one of hafnium boride, hafnium oxide, hafnium nitride, hafnium silicide, and hafnium aluminide. (U.K.)

  17. The comparison of corrosion resistance between Baosteel's alloy 690 tube and foreign alloy 690 tube

    International Nuclear Information System (INIS)

    Ma Mingjuan; Zhang Lefu; Li Yan

    2012-01-01

    Alloy 690 having excellent corrosion resistance is widely used for SG tubes. The intergranular corrosion and pitting corrosion resistance of Baosteel's alloy 690 tube, Country A alloy 690 tube and Country B alloy 690 tube have been analysed by comparison. It shows that: The intergranular corrosion of Baosteel's alloy 690 tube tested complied with ASTM G28 Standard could satisfy the technical requirement. However.some of Baosteel's alloy 690 tube in intergranular corrosion resistance had less performance than Country A. In addition, pitting corrosion tested with ASTM G48 Standard shown the Baosteel's alloy 690 tube better than Country B. (authors)

  18. Dynamic characteristics of heat exchanger tubes vibrating in a tube support plate inactive mode

    International Nuclear Information System (INIS)

    Jendrzejczyk, J.A.

    1985-01-01

    Tubes in shell-and-tube heat exchangers, including nuclear plant steam generators, derive their support from longitudinally positioned tube support plates (TSPs). Typically there is a clearance between the tube and TSP hole. Depending on design and fabrication tolerances, the tube may or may not contact all of the TSPs. Noncontact results in an inactive TSP which can lead to detrimental flow induced tube vibrations under certain conditions dependent on the resulting tube-TSP interaction dynamics and the fluid excitation forces. The purpose of this study is to investigate the tube-TSP interaction dynamics. Results of an experimental study of damping and natural frequency as functions of tube-TSP diametral clearance and TSP thickness are reported. Calculated values of damping ratio and frequency of a tube vibrating within an inactive TSP are also presented together with a comparison of calculated and experimetnal quantities

  19. Advanced pressure tube sampling tools

    International Nuclear Information System (INIS)

    Wittich, K.C.; King, J.M.

    2002-01-01

    Deuterium concentration is an important parameter that must be assessed to evaluate the Fitness for service of CANDU pressure tubes. In-reactor pressure tube sampling allows accurate deuterium concentration assessment to be made without the expenses associated with fuel channel removal. This technology, which AECL has developed over the past fifteen years, has become the standard method for deuterium concentration assessment. AECL is developing a multi-head tool that would reduce in-reactor handling overhead by allowing one tool to sequentially sample at all four axial pressure tube locations before removal from the reactor. Four sets of independent cutting heads, like those on the existing sampling tools, facilitate this incorporating proven technology demonstrated in over 1400 in-reactor samples taken to date. The multi-head tool is delivered by AECL's Advanced Delivery Machine or other similar delivery machines. Further, AECL has developed an automated sample handling system that receives and processes the tool once out of the reactor. This system retrieves samples from the tool, dries, weighs and places them in labelled vials which are then directed into shielded shipping flasks. The multi-head wet sampling tool and the automated sample handling system are based on proven technology and offer continued savings and dose reduction to utilities in a competitive electricity market. (author)

  20. EP 1000 steam generator tube rupture analyses

    International Nuclear Information System (INIS)

    Saiu, G.; Frogheri, M.; Schulz, T.L.

    2001-01-01

    European electrical utility organizations together with Westinghouse and Ansaldo are participating in a program to utilize the Westinghouse passive nuclear plant technology to develop a plant which meets the European Utility Requirements (EUR) and is expected to be licensable in Europe. The program was initiated in 1994 and the plant is designated EP1000. The EP1000 design is notable for simplicity that comes from a reliance on passive safety systems to enhance plant safety. The use of passive safety systems has provided significant and measurable improvements in plant simplification, safety, reliability, investment protection and plant costs. These systems use only natural forces such as gravity, natural circulation, and compressed gas to provide the driving forces for the systems to adequately cool the reactor core following an initiating event. The EP1000 builds up on the Westinghouse passive nuclear plant technology to enhance plant safety and meet European Utility Requirements and specific European National Safety Criteria. This paper summarizes the main results of the Steam Generator Tube Rupture (SGTR) analysis activity, performed in Phase 2B of the European Passive Plant Program. The purpose of the study is to provide evidence that the passive safety system performance provides a significant improvement in terms of safety, providing significant margins to steam generator overfilling and reducing the need for operator actions. The behavior of the EP1000 plant following SGTR accidents has been analyzed by means of the RELAP5/Mod3.2 code. Sensitivity cases were performed, to address the impact of varying the number of steam generator tubes that rupture, and the potential adverse interactions that could result from operation of control systems (i.e., Chemical and Volume Control System, Startup Feedwater). Analyses have also been performed to define and verify improved protection system logic to avoid possible steam generator safety valve challenges both in the