WorldWideScience

Sample records for sensitive immunoblotting method

  1. A sensitive immunoblotting method for screening of microalbuminuria in diabetic patient's urine

    International Nuclear Information System (INIS)

    Abdolkhaleg, D.; Behrooz, S.

    2005-01-01

    Urinary albumin excretion is a useful marker in the prognosis of diabetic nephropathy and microvascular diseases. Methods such as enzyme linked immunosorbent assay (ELISA), radio immunoassay(RIA), radial immunodiffusion, albu screen, micro bumin and micral test are usually used for detection and screening of microalbuminuria in these patients. With consideration to the cost of an assay, methods such as ELISA and RIA are not suitable methods for screening purpose. Therefore, the aim of this work is to set a dot immunoblotting method for the measurement and screening of microalbumin in urine samples. The study was conducted during the period August 2001 to June 2003 at the National Research Center for Genetic Engineering and Biotechnology (NRCGEB) and Pars Hospital Laboratory of Tehran, Iran on 96 diabetic patients urine samples. First, anti human albumin antibodies (Abs) were produced in rabbit and immunoglobulin G (IgG) fraction was purified by protein-A affinity chromatography. Titer of Abs and optimum incubation conditions were tested by direct ELISA. Then different concentration of human albumin (0-300 mg/l) was loaded to nitrocellulose membranes and was assayed by dot immunoblotting method. The specificity and cross reactivity of Abs was tested by SDS-PAGE electrophoresis and western immunoblotting. The sensitivity of the method was calculated from human albumin calibration curve and compared with commercial immunoturbidimetric assays. Our results indicates that in using IgG with the concentrations 0.5-1 ug/ml (2 x 10-5 to 10-4 dilutions) the intensity of color directly increased with the increase of human albumin standards in blots. Western immunoblotting of urine samples did not show any cross reactivity with other urine proteins. Comparison of results of this method by commercial immunoturbidimetric methods indicates the correlation regression of approximately 0.979. The sensitivity of the method was approximately 5 mg/L of human albumin. This simple

  2. A simple immunoblotting method after separation of proteins in agarose gel

    DEFF Research Database (Denmark)

    Koch, C; Skjødt, K; Laursen, I

    1985-01-01

    A simple and sensitive method for immunoblotting of proteins after separation in agarose gels is described. It involves transfer of proteins onto nitrocellulose paper simply by diffusion through pressure, a transfer which only takes about 10 min. By this method we have demonstrated the existence ...

  3. Comparative sensitivity of 125I-protein A and enzyme-conjugated antibodies for detection of immunoblotted proteins

    International Nuclear Information System (INIS)

    Bernstein, J.M.; Stokes, C.E.; Fernie, B.

    1987-01-01

    Immunoblotting is a powerful technique for the detection of small amounts of immunologically interesting proteins in unpurified preparations. Iodinated protein A (PA) has been widely used as a second antibody for detection of proteins; however, it does not bind equally well to immunoglobulins from different species nor does it bind to all subclasses of immunoglobulin G (IgG). We compared the sensitivity of [ 125 I]PA with those of both horseradish peroxidase-conjugated second antibodies (HRP) and glucose oxidase-anti-glucose oxidase (GAG) soluble complexes for visualizing bovine serum albumin, human IgG, or human C3 which was either dot blotted or electroblotted to nitrocellulose. [ 125 I]PA was uniformly 10- to 100-fold less sensitive than either HRP or GAG. GAG was more sensitive than HRP except for C3 (electroblotting) and bovine serum albumin and IgG (dot blotting), in which they were equivalent. In general, dot blotting was 10- to 1000-fold more sensitive than electroblotting. Although relative sensitivities varied depending on the proteins analyzed and the antisera used, GAG appeared to be superior to [ 125 I]PA and HRP for detection of immunoblotted proteins

  4. Use of immunoblotting assay improves the sensitivity of paracoccidioidomycosis diagnosis

    Directory of Open Access Journals (Sweden)

    D. F. Silva

    2008-01-01

    Full Text Available The purpose of this work was to evaluate two serological assays: double immunodiffusion (DI and immunoblotting (IB in immunodiagnosis of paracoccidioidomycosis (PCM. We evaluated by IB assay 23 sera samples from patients with clinical confirmation of PCM, all of them with negative DI results against culture filtrate from Paracoccidioides brasiliensis isolate 113. For IB, as well as for comparative DI assay, we employed soluble components of the cell wall outer surface (SCCWOS from P. brasiliensis isolate 113 cultivated at 36°C in Fava-Neto's agar medium for 5 and 10 days. Among the 20 sera samples analyzed by DI, 13 (65% were negative and 7 (35% were positive against SCCWOS obtained on the 5th and 10th days. By IB assay, 95.4% and 100% of sera reacted against gp43 and gp70 present in SCCWOS from the 5th day and 95.6% recognized these fractions when evaluated against SCCWOS from the 10th day. Our results demonstrated that the use of an immunoenzymatic assay significantly improves the sensitivity of PCM immunodiagnosis and also suggests that at least two serological tests for antibody detection should be adopted in cases of questionable diagnosis.

  5. Comparison between dot-immunoblotting assay and clinical sign determination method for quantifying avian infectious bronchitis virus vaccine by titration in embryonated eggs.

    Science.gov (United States)

    Yuk, Seong-Su; Kwon, Jung-Hoon; Noh, Jin-Yong; Hong, Woo-Tack; Gwon, Gyeong-Bin; Jeong, Jei-Hyun; Jeong, Sol; Youn, Ha-Na; Heo, Yong-Hwan; Lee, Joong-Bok; Park, Seung-Yong; Choi, In-Soo; Song, Chang-Seon

    2016-04-01

    A sensitive and specific method for measuring the vaccine titer of infectious bronchitis virus (IBV) is important to commercial manufacturers for improving vaccine quality. Typically, IBV is titrated in embryonated chicken eggs, and the infectivity of the virus dilutions is determined by assessing clinical signs in the embryos as evidence of viral propagation. In this study, we used a dot-immunoblotting assay (DIA) to measure the titers of IBV vaccines that originated from different pathogenic strains or attenuation methods in embryonated eggs, and we compared this assay to the currently used method, clinical sign evaluation. To compare the two methods, we used real-time reverse transcription-PCR, which had the lowest limit of detection for propagated IBV. As a clinical sign of infection, dwarfism of the embryo was quantified using the embryo: egg (EE) index. The DIA showed 9.41% higher sensitivity and 15.5% higher specificity than the clinical sign determination method. The DIA was particularly useful for measuring the titer of IBV vaccine that did not cause apparent stunting but propagated in embryonated chicken eggs such as a heat-adapted vaccine strain. The results of this study indicate that the DIA is a rapid, sensitive, reliable method for determining IBV vaccine titer in embryonated eggs at a relatively low cost. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Immunoblot Patterns of Taenia asiatica Taeniasis

    Science.gov (United States)

    Jeon, Hyeong-Kyu

    2009-01-01

    Differential diagnosis of Taenia asiatica infection from other human taeniases by serology has been tested. An enzyme-linked immunoelectrotransfer blot (EITB) was applied to subjected human sera and tapeworm materials. Thirty-eight proteins reactive to serum IgG were observed between 121 and 10 kDa in adult worms, and more than 22 serum-reactive components between 97 kDa and 21.5 kDa were observed in eggs of T. asiatica. Antigens of adult T. asiatica revealed immunoblot bands between 120 and 21.5 kDa against T. asiatica infected sera. Antigens of adult Taenia saginata revealed 110-100, 66, 58-56, and 46 kDa immunoblot bands against T. asiatica infected sera. Antigens of adult Taenia solium also revealed 99-97, 68-66, and 46 kDa bands against T. asiatica infected sera. The immunoblot band of 21.5 kDa exhibited specificity to T. asiatica. PMID:19290097

  7. Immunoblot patterns of Taenia asiatica taeniasis.

    Science.gov (United States)

    Jeon, Hyeong-Kyu; Eom, Keeseon S

    2009-03-01

    Differential diagnosis of Taenia asiatica infection from other human taeniases by serology has been tested. An enzyme-linked immunoelectrotransfer blot (EITB) was applied to subjected human sera and tapeworm materials. Thirty-eight proteins reactive to serum IgG were observed between 121 and 10 kDa in adult worms, and more than 22 serum-reactive components between 97 kDa and 21.5 kDa were observed in eggs of T. asiatica. Antigens of adult T. asiatica revealed immunoblot bands between 120 and 21.5 kDa against T. asiatica infected sera. Antigens of adult Taenia saginata revealed 110-100, 66, 58-56, and 46 kDa immunoblot bands against T. asiatica infected sera. Antigens of adult Taenia solium also revealed 99-97, 68-66, and 46 kDa bands against T. asiatica infected sera. The immunoblot band of 21.5 kDa exhibited specificity to T. asiatica.

  8. Immunological diagnosis of human hydatid cyst using Western immunoblotting technique

    Directory of Open Access Journals (Sweden)

    Mahboubeh Hadipour

    2016-01-01

    Full Text Available Background: Echinococcosis is a parasitic disease with worldwide distribution which is caused by the tapeworms Echinococcus granulosus. Diagnosis of the disease relies on imaging techniques, but the techniques are not able to differentiate the cyst from benign or malignant tumors; hence, appropriate serologic methods are required for the differential diagnosis of the infection. Materials and Methods: In this investigation, different sheep hydatid cyst antigens probed with thirty sera of patients with hydatid cyst and also thirty human normal sera using Western immunoblotting technique. Considering results of surgery as gold standard, sensitivity and specificity of Western blotting was estimated. Results: Sera of 29, 26, and 16 patients with hydatid cyst reacted with specific bands of hydatid cyst fluid (HCF, protoscolex crude antigen, and cyst wall crude antigen, respectively. However, none of the normal human sera reacted with those specific bands. Conclusion: A 20 kDa band of sheep HCF is an appropriate antigen for serodiagnosis of hydatid cyst infection.

  9. Detection of Yersinia enterocolitica in milk powders by cross-priming amplification combined with immunoblotting analysis.

    Science.gov (United States)

    Zhang, Hongwei; Feng, Shaolong; Zhao, Yulong; Wang, Shuo; Lu, Xiaonan

    2015-12-02

    Yersinia enterocolitica (Y. enterocolitica) is frequently isolated from a wide variety of foods and can cause human yersiniosis. Biochemical and culture-based assays are common detection methods, but require a long incubation time and easily misidentify Y. enterocolitica as other non-pathogenic Yersinia species. Alternatively, cross-priming amplification (CPA) under isothermal conditions combined with immunoblotting analysis enables a more sensitive detection in a relatively short time period. A set of specific displacement primers, cross primers and testing primers was designed on the basis of six specific sequences in Y. enterocolitica 16S-23S rDNA internal transcribed spacer. Under isothermal condition, amplification and hybridization were conducted simultaneously at 63°C for 60 min. The specificity of CPA was tested for 96 different bacterial strains and 165 commercial milk powder samples. Two red lines were developed on BioHelix Express strip for all of the Y. enterocolitica strains, and one red line was shown for non-Y. enterocolitica strains. The limit of detection of CPA was 10(0)fg for genomic DNA (1000 times more sensitive than PCR assay), 10(1) CFU/ml for pure bacterial culture, and 10(0) CFU per 100 g milk powder with pre-enrichment at 37°C for 24 h. CPA combined with immunoblotting analysis can achieve highly specific and sensitive detection of Y. enterocolitica in milk powder in 90 min after pre-enrichment. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. 2D-immunoblotting analysis of Sporothrix schenckii cell wall

    Directory of Open Access Journals (Sweden)

    Estela Ruiz-Baca

    2011-03-01

    Full Text Available We utilized two-dimensional gel electrophoresis and immunoblotting (2D-immunoblotting with anti-Sporothrix schenckii antibodies to identify antigenic proteins in cell wall preparations obtained from the mycelial and yeast-like morphologies of the fungus. Results showed that a 70-kDa glycoprotein (Gp70 was the major antigen detected in the cell wall of both morphologies and that a 60-kDa glycoprotein was present only in yeast-like cells. In addition to the Gp70, the wall from filament cells showed four proteins with molecular weights of 48, 55, 66 and 67 kDa, some of which exhibited several isoforms. To our knowledge, this is the first 2D-immunoblotting analysis of the S. schenckii cell wall.

  11. Immunoblotting studies of coagulation factor XII, plasma prekallikrein, and high molecular weight kininogen

    International Nuclear Information System (INIS)

    Laemmle, B.B.; Berrettini, M.; Griffin, J.H.

    1987-01-01

    Immunoblotting techniques for the qualitative and quantitative analysis of FXII, PK, and HMWK in whole plasma are presented. Sensitive, specific, and quantitative immunodetection of FXII and PK can be achieved by developing the blots with polyclonal antiserum followed by radiolabeled FXII or PK, respectively. This approach is based on the assumption that bivalent antibodies bind monovalently to the NC-bound antigen and have available binding sites to bind radiolabeled antigen derived from the fluid phase. This radiolabeled antigen overlay principle may be generally useful for immunodetection of any trace protein in complex mixtures, provided that the radiolabeled purified antigen is available. Immunoblotting may also be helpful for the partial characterization of the structural or functional abnormalities of CRM-positive variant molecules. For example, earlier studies of a FXII-variant molecule that had been purified and characterized were supported by immunoblotting studies of the CRM-positive deficient plasma. Quantitative measurement of HMWK is possible using a monoclonal antibody directed against the light chain of HMWK followed by radiolabeled secondary antibody. Quantitation of cleaved and single-chain HMWK is possible using dilutions of dextran sulfate-activated NHP on unreduced SDS-PAGE and dilutions of unactivated NHP with reduced SDS-PAGE as standards. These assays allow assessment of the degree of in vivo activation of the contact system in various disease states

  12. A recombinant Toscana virus nucleoprotein in a diagnostic immunoblot test system.

    Science.gov (United States)

    Schwarz, T F; Gilch, S; Schätzl, H M

    1998-01-01

    Sandfly fever, a vector-borne disease endemic in the Mediterranean region, is caused by Toscana virus (TOS). The disease is increasingly important as a travel-related infection. Serological diagnosis is currently dependent on viral antigens derived from TOS-infected cell cultures. In this study, we report the cloning and expression of the TOS nucleoprotein (N) in Escherichia coli and evaluation of the recombinant (r) TOS N protein as an antigen for immunoblot assays. The TOS N gene was amplified by reverse-transcriptase polymerase chain reaction and cloned into the bacterial expression vector pTrcHis-A. Sera with known TOS antibody status were used to evaluate the immunoblot assay. The expressed rTOS N protein was purified and used as antigen for immunoblots. By recombinant immunoblot, the TOS antibody status (IgM and/or IgG) of the test panel was correctly identified. No cross-reactivity was detected. The rTOS N protein is useful as an antigen for immunoblot assays, and will enable more laboratories to perform TOS antibody diagnosis.

  13. Specific IgE Antibodies in Young Children with Atopic Dermatitis--Correlation of Multiple Allergen Simultaneous Immunoblot Test and ImmunoCap System.

    Science.gov (United States)

    Konopka, Ewa; Ceregra, Aldona; Maciorkowska, Elzbieta; Surowska, Barbara; Trojanowska, Ilona; Roszko-Kirpsza, Izabela; Cukrowska, Bozena

    2016-01-01

    Sensitization to food allergens is a common condition in pediatric atopic dermatitis (AD). Recently, the multiple allergen simultaneous test (MAST) allowing for a comprehensive assessment of atopy has been developed, but the usefulness in young AD children is not known. The aim of this study was to determine IgE specificity in AD children using MAST and to compare the results for selected food allergens with the reference ImmunoCap system. The study enrolled 50 children up to 2 years old with a diagnosis of AD. IgE antibodies were measured with the MAST-immunoblots. Children with specific IgE levels ≥ 0.35 kU/L were identified as sensitized to allergens. Most often children were sensitized to food allergens (egg white and yolk, hazelnuts, potato, cow's milk proteins, wheat flour, codfish, and soybean), but a high percentage of them also had IgE antibodies against house dust mites (12%), grass (10%), and birch (10%). Eight percent of children were sensitized to domestic animals (cats and dogs). Almost perfect (kappa index 0.8 - 1.0) and substantial (kappa index 0.6 - 0.8) agreement between MAST and ImmunoCap was found for food allergens except codfish. Pearson's analysis of antibody classes showed a very strong correlation between two methods (r = 0.8 - 1.0) for egg white, hazelnuts, potato, cow's milk proteins, wheat flour, and soybean, and a strong correlation (r = 0.6 - 0.79) was observed for peanut, egg yolk, and codfish. The study showed the frequent occurrence of IgE antibodies against food and airborne and animal allergens in young AD children and confirmed the usefulness of MAST-immunoblots for screening of sensitization in pediatric patients.

  14. Detection of serum anti-B/B’ UsnRNP antibodies in patients with connective tissue diseases by immunoblotting

    Directory of Open Access Journals (Sweden)

    L. Iaccarino

    2011-09-01

    Full Text Available Objective: To investigate the reliability of the immunoblot method in the detection of serum immunoreactivity towards the B/B’ polypeptides of U small nuclear ribonucleoproteins (UsnRNP and to assess the significance of these antibodies in connective tissue disease (CTD patients. Methods: We tested the sera of 348 patients with CTD (101 SLE, 51 systemic sclerosis, 53 primary Sjogren’s syndrome, 27 poly/dermatomyositis, 15 rheumatoid arthritis and 101 overlap CTD, of 31 matched healthy subjects and 13 patients with primary Epstein-Barr virus (EBV infection with high titre IgG anti-EBV antibodies. IgG anti-UsnRNP antibodies were determined by immunoblotting on nuclear extract from Raji cells (an EBV-immortalised human B lymphoid cell line and Jurkat cells (a human T lymphoid cell line. Anti-dsDNA antibodies were detected by indirect immunofluorescence on Crithidia luciliae and anti-ENA by counterimmunoelectrophoresis. Anti-dsDNA activity and avidity were measured in SLE sera by ELISA with Scatchard analysis. Results were statistically analysed by chi-square and Mann-Whitney tests. Results: A high frequency of anti-B/B’ antibodies was found in the sera of CTD patients, confined to SLE (54.4% and overlap CTD with SLE features (55,2%. Anti-B/B’ immune reactivity was closely associated with other anti-UsnRNP specificities, gel precipitating anti-nRNP and anti-P antibodies. Nine out of 15 (60% anti-B/B’ positive/anti-ENA negative lupus sera on Raji blots were confirmed to be positive also on Jurkat blots. The sera from patients with EBV infection provided, on Raji blots, completely different band patterns from those obtained with auto-immune sera. Conclusions. The Sm B/B’ proteins are the predominant or, at least, the most frequently targeted antigens of the UsnRNP auto-immune response in SLE and “lupus-like” overlap CTD. Moreover, anti-B/B’ is diagnostically specific for CTD with SLE features. Immunoblotting on human B lymphoid cells

  15. Soybean flour asthma: detection of allergens by immunoblotting

    International Nuclear Information System (INIS)

    Bush, R.K.; Schroeckenstein, D.; Meier-Davis, S.; Balmes, J.; Rempel, D.

    1988-01-01

    A 43-year-old woman developed asthma 6 years after beginning work in a food-processing plant in which soybean flour was used as a protein extender. Symptoms of sneezing, coughing, and wheezing would begin within minutes of exposure to soybean flour and resolve 2 hours after exposure ceased. Skin tests were positive to a soy extract prepared from the flour. Airway hyperreactivity was confirmed by a positive bronchial challenge to methacholine. Bronchial challenge with soybean flour produced an immediate increase in specific airway resistance from 5.0 to 22.7 L. cm of H2O/L/sec. There was no response to challenge with lactose. The patient's allergic response to soy-flour extract was further characterized by several immunologic methods. IgE binding to soy-flour protein by direct RAST was 5.98 times that of a normal control serum. The soy-flour extract was separated by dodecyl sulfate-polyacrylamide gel electrophoresis. Twenty-four protein bands were detected in the crude soy-flour extract. After immunoblotting and subsequent autoradiography, nine proteins with molecular weights ranging from 54,500 to 14,875 were found. Cross-reactivity studies with other legumes demonstrated apparent immunologic identity between a component in green pea extract and a soybean protein with a molecular weight of 17,000. The clinical significance of this cross-reactivity is not known. We conclude that in this case of occupational asthma to soybean flour, multiple allergens were involved. Immunoblotting may be useful in identifying the allergens involved in occupational asthma

  16. Comparison of two enzyme-linked immunosorbent assays and one rapid immunoblot assay for detection of herpes simplex virus type 2-specific antibodies in serum

    NARCIS (Netherlands)

    Groen, J; Van Dijk, G; Niesters, H G; Van Der Meijden, W I; Osterhaus, A D

    The sensitivities and specificities of three immunoassays for the detection of herpes simplex virus type 2 (HSV-2)-specific immunoglobulin G antibodies in serum, including the one-strip rapid immunoblot assay (RIBA; Chiron Corporation) and two indirect enzyme immunosorbent assays (EIA; Gull

  17. Comparison of Mother and Child Antibodies That Target High-Molecular-Mass Toxoplasma gondii Antigens by Immunoblotting Improves Neonatal Diagnosis of Congenital Toxoplasmosis

    Science.gov (United States)

    Wallon, Martine; Faucher, Benoit; Piarroux, Renaud; Peyron, François; Franck, Jacqueline

    2012-01-01

    This retrospective study proposes a new reading of immunoblotting (IB) in the diagnosis of congenital toxoplasmosis. Our findings demonstrate that a three-IgM-band association at 75, 90, and 100 kDa called the IgM triplet increases the sensitivity to 95.8% when combined with prenatal and serological neonatal tests. PMID:22695159

  18. Hyposensitization therapy with whole pollen extract or purified allergens monitored by immunoblotting

    DEFF Research Database (Denmark)

    Jarolim, E; Matthiesen, F; Skov, P S

    1990-01-01

    . Inhibition experiments using allergenic components isolated by preparative sodium dodecyl sulphate-polyacrylamide gel electrophoresis indicated that all antigenic components of timothy grass pollen detected in immunoblot dispose of private and cross-reactive determinants for binding of human IgE. The worse......Patients allergic to grass pollen were hyposensitized with two major allergenic components or whole extract of timothy grass pollen. Specific IgE, IgG1, and IgG4 formed during immunotherapy were analyzed by immunoblotting. Similar antibody-binding patterns were observed in both patient groups...

  19. Erythema migrans and serodiagnosis by enzyme immunoassay and immunoblot with three borrelia species.

    Science.gov (United States)

    Stanek, G; Breier, F; Menzinger, G; Schaar, B; Hafner, M; Partsch, H

    1999-12-10

    There is wide divergence of opinion between physicians regarding the use of serological measures for the diagnosis and treatment of erythema migrans, the hallmark of Lyme borreliosis. We studied the outcome of an enzyme immunoassay and immunoblot (Western blot) used on the sera of patients who had suffered tick bite and erythema migrans, and had been subsequently treated with various antibiotics. Ninety-nine consecutive patients presenting with erythema migrans after tick bite were prospectively recruited at the outpatient department of two Vienna City hospitals and at the consultation office for Lyme borreliosis of the Institute of Hygiene. University Vienna. Blood samples were taken before antibiotic treatment and 3 and 6 months thereafter. Blood samples from 100 blood donors served as controls. Antibodies against Borrelia burgdorferi sensu lato were determined by enzyme immunoassay (IgG and IgM EIA) and by IgG immunoblot. The latter was performed with isolates of B. alzelii (H2) B. burgdorferi sensu stricto (Le) and B. garinii (W) from Austrian patients. The 4 interpretation criteria for immunoblot results were: A (3 bands out of 8), B (2 bands out of 9), C and D (1 band out of 6). In all patients, the erythema resolved within the treatment period. No complications secondary to the borrelia infection were registered. After treatment there was no significant change in titre, nor was there a difference in the immunoblot pattern between the first, second and third serum samples. Serum antibodies to B. burgdorferi were positive by EIA in 22.9% (IgG) and 2.5% (IgM). Immunoblot results offered by borrelia species and by the interpretation criteria, ranging between 8.3% (criterion A, strain Le) and 44.2% (criterion D, strain H2). By EIA, control samples were IgG and IgM positive in 5% and 1%, respectively. Positive immunoblot results with strain H2 were found in 9%, 13%, 18%, and 20% by the criteria A through D respectively. After antibiotic treatment of erythema

  20. An immunoblotting analysis of cross-reactivity between melon, and plantago and grass pollens.

    Science.gov (United States)

    García Ortiz, J C; Ventas, P; Cosmes, P; López-Asunsolo, A

    1996-01-01

    It is known that most patients with type I allergy to pollens also suffer intolerance to fruits. Recently, an epidemiological and CAP-inhibition study has shown a new clustering of allergy between melon and Plantago and grass pollens. The aim of the present study was to confirm these results by immunoblotting analysis and inhibition of immunoblotting. Sera from 3 patients with confirmed allergy to melon, and Dactylis glomerata and Plantago lanceolata pollens were used for the in vitro studies. SDS-PAGE and immunoblotting analysis with a pool of sera revealed that several distinct protein bands were shared by the three extracts at 14, 31, and a spectrum between 40 and 70 kDa, approximately. Immunoblotting inhibition experiments, performed with extracts of melon, Plantago and Dactylis, showed that all allergens of melon blotting were almost completely inhibited by grass and Plantago pollen extracts. Inversely, the melon extract was capable of inhibiting IgE-binding to various allergens of Dactylis at high mol mass and partially to the band at 14 kDa. Moreover, the melon almost totally inhibited the IgE-binding capacity to the proteins of Plantago extract. Taken together, the results support the presence of structurally similar allergens in melon, Plantago and grass pollens, and that all allergenic epitopes of the melon are present in these pollens.

  1. Evaluation of antibody responses in american visceral leishmaniasis by ELISA and immunoblot Avaliação da resposta imune humoral na leishmaniose visceral americana pelos métodos ELISA e "immunoblot"

    Directory of Open Access Journals (Sweden)

    Thomas G. Evans

    1989-06-01

    Full Text Available American visceral leishmaniasis (AVL is an important disease among children of northeast Brazil. In order to characterize antibody responses during AVL, sera of hospitalized patients were analyzed by ELISA and Western blot using a Leishmania chagasi antigen preparation. The ELISA was positive (asorbance [greater than or equals to] 0.196 at a serum dilution of 1:1024 in all patients at presentation, and fell to ward control levels over the following year. Only one of 72 control subjects tested positive, and that donor had a sibling with AVL. Immunoblots of the patients' sera recognized multiple bands, the most frequent of which were at approximately 116 kDa, 70 kDa, and 26 kDa. Less frenquently observed were bands at approximately 93 kDa, 74 kDa, 62 kDa, 46 kDa and 32 kDa. The ELISA responses and patterns of banding were distinctive for AVL, and could be used to differentiate patients with AVL from those with Chagas' disease of cutaneous leishmaniasis. Sera from six AVL patients followed for up to six weeks after treatment identified no new bands. Sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE of surface iodinated parasite proteins showed one major band and four minor bands, whereas SDS-PAGE of biotinylated prarasite proteins revealed a banding pattern similar to those of patient sera. AVL appears to produce characteristic immunoblot patterns which can be used along with a sensitive screening ELISA to diagnose AVL.A leishmaniose visceral americana é uma doença importante entre crianças do nordeste do Brasil. Com o objetivo de caracterizar a resposta imune humoral durante o curso da doença, foram analisados soros de pacientes hospitalizados, pelos métodos ELISA e Western blot, usando-se preparaçöes de antígenos de Leishmania donovani chagasi. O teste de ELISA foi positivo (absorbância > 0,196, numa diluiçäo de 1: 1024, em todos os pacientes no início da doença, diminuindo no decorrer do ano, para os níveis dos

  2. A long-term follow-up study of hyposensitization with immunoblotting

    DEFF Research Database (Denmark)

    Jarolim, E; Poulsen, L K; Stadler, B M

    1990-01-01

    The formation of specific IgE, IgG1, and IgG4 antibodies was investigated by immunoblotting during hyposensitization with timothy grass-pollen extract and 6 years later, Until the end of immunotherapy, specific IgG antibody levels increased. Also simultaneously, the number of allergenic component...

  3. Signal Peptide and Denaturing Temperature are Critical Factors for Efficient Mammalian Expression and Immunoblotting of Cannabinoid Receptors*

    Science.gov (United States)

    WANG, Chenyun; WANG, Yingying; WANG, Miao; CHEN, Jiankui; YU, Nong; SONG, Shiping; KAMINSKI, Norbert E.; ZHANG, Wei

    2013-01-01

    Summary Many researchers employed mammalian expression system to artificially express cannabinoid receptors, but immunoblot data that directly prove efficient protein expression can hardly be seen in related research reports. In present study, we demonstrated cannabinoid receptor protein was not able to be properly expressed with routine mammalian expression system. This inefficient expression was rescued by endowing an exogenous signal peptide ahead of cannabinoid receptor peptide. In addition, the artificially synthesized cannabinoid receptor was found to aggregate under routine sample denaturing temperatures (i.e., ≥95°C), forming a large molecular weight band when analyzed by immunoblotting. Only denaturing temperatures ≤75°C yielded a clear band at the predicted molecular weight. Collectively, we showed that efficient mammalian expression of cannabinoid receptors need a signal peptide sequence, and described the requirement for a low sample denaturing temperature in immunoblot analysis. These findings provide very useful information for efficient mammalian expression and immunoblotting of membrane receptors. PMID:22528237

  4. Comparison of immunoblotting (IgA and IgG) and the Goldmann-Witmer coefficient for diagnosis of ocular toxoplasmosis in immunocompetent patients.

    Science.gov (United States)

    Mathis, Thibaud; Beccat, Sylvain; Sève, Pascal; Peyron, François; Wallon, Martine; Kodjikian, Laurent

    2018-01-17

    Ocular toxoplasmosis (OT) is a common cause of posterior uveitis worldwide. The diagnosis of OT is based on clinical findings, but in most cases, laboratory tests are required to confirm the aetiology, especially when other diseases are suspected. The aim of this study was to evaluate which methods, between the Goldmann-Witmer coefficient (GWC) and immunoblotting (IB) with both IgG and IgA, in aqueous humour (AH) samples, can be the most sensitive to diagnose OT, in current practice, especially in the first three weeks. Retrospectively reviewed records of 87 consecutive patients who had underwent AH and serum sample, 42 patients with suspected OT and 45 patients with suspected other ocular inflammatory diseases. All samples were analysed by both GWC and IB. The GWC was significant in 47.6% of patients presenting with suspected OT. The intraocular production of specific antibody anti-Toxoplasma gondii IgG and IgA was revealed by IB in 71.4% of samples. The combination of these two methods increased the sensitivity to 76.2%. Based on the interval between symptom onset and paracentesis, IB had a greater sensitivity than GWC when sample of AH was taken in the first three weeks (64.7% vs 23.5%, P=0.039), while the difference between the sensitivity of IB and GWC was less important in cases with an interval >3 weeks (76% vs 64% P=0.625). IB seems to be more useful than the GWC if only one of these methods can be performed, especially during the first three weeks after symptom onset. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Validation of commercially available sphingosine kinase 2 antibodies for use in immunoblotting, immunoprecipitation and immunofluorescence [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Heidi A. Neubauer

    2017-03-01

    Full Text Available Sphingosine kinase 2 (SK2 is a ubiquitously expressed lipid kinase that has important, albeit complex and poorly understood, roles in regulating cell survival and cell death. In addition to being able to promote cell cycle arrest and apoptosis under certain conditions, it has recently been shown that SK2 can promote neoplastic transformation and tumorigenesis in vivo. Therefore, well validated and reliable tools are required to study and better understand the true functions of SK2. Here, we compare two commercially available SK2 antibodies: a rabbit polyclonal antibody from Proteintech that recognizes amino acids 266-618 of human SK2a, and a rabbit polyclonal antibody from ECM Biosciences that recognizes amino acids 36-52 of human SK2a. We examine the performance of these antibodies for use in immunoblotting, immunoprecipitation and immunofluorescence staining of endogenous SK2, using human HEK293 and HeLa cell lines, as well as mouse embryonic fibroblasts (MEFs. Furthermore, we assess the specificity of these antibodies to the target protein through the use of siRNA-mediated SK2 knockdown and SK2 knockout (Sphk2-/- MEFs. Our results demonstrate that the Proteintech anti-SK2 antibody reproducibly displayed superior sensitivity and selectivity towards SK2 in immunoblot analyses, while the ECM Biosciences anti-SK2 antibody was reproducibly superior for SK2 immunoprecipitation and detection by immunofluorescence staining. Notably, both antibodies produced non-specific bands and staining in the MEFs, which was not observed with the human cell lines. Therefore, we conclude that the Proteintech SK2 antibody is a valuable reagent for use in immunoblot analyses, and the ECM Biosciences SK2 antibody is a useful tool for SK2 immunoprecipitation and immunofluorescence staining, at least in the human cell lines employed in this study.

  6. Immunomagnetic separation combined with colony immunoblotting for selective enrichment and detection of piliated Lactobacillus rhamnosus strains.

    Science.gov (United States)

    Yang, Z Q; Wei, Y F; Rao, S Q; Gao, L; Yin, Y Q; Xue, F; Fang, W M; Gu, R X; Jiao, X A

    2016-11-01

    Piliated Lactobacillus rhamnosus (pLR) strains have attracted much attention owing to their excellent mucus adhering capacity and immunomodulatory effects. Here, we aimed to develop a rapid, sensitive method for isolating pLR strains in complex ecosystems using immunomagnetic separation (IMS) with colony immunoblotting (CIB). Magnetic nanobeads (diameter: 180 nm) conjugated with anti-pLR SpaA pilin antibodies (anti-SpaA) were prepared and used to preconcentrate pLR strains in samples, followed by confirmation with anti-SpaA-based CIB analysis. Under optimized experimental conditions, IMS-CIB selectively recovered pLR strains from 10 7  CFU ml -1 of faecal microbiota samples spiked with 2·9 × 10 1 to 2·4 × 10 6  CFU ml -1 of pLR strains. No positive colonies were detected in samples without addition of pLR strains. The detection limit of IMS-CIB was 29 CFU pLR ml -1 of faecal microbiota, which is much lower than that of CIB without IMS preconcentration (2·0 × 10 4  CFU ml -1 ). IMS-CIB allowed selective preconcentration of pLR strains in highly heterogeneous bacterial suspensions and direct detection of pLR colonies, which remained readily available for subsequent isolation. Our findings established an effective method for selective enrichment and detection of pLR strains. © 2016 The Society for Applied Microbiology.

  7. Relevance of Allergenic Sensitization to Cynodon dactylon and Phragmites communis: Cross-reactivity With Pooideae Grasses.

    Science.gov (United States)

    López-Matas, M A; Moya, R; Cardona, V; Valero, A; Gaig, P; Malet, A; Viñas, M; García-Moral, A; Labrador, M; Alcoceba, E; Ibero, M; Carnés, J

    The homologous group of sweet grasses belongs to the Pooideae subfamily, but grass pollen species from other subfamilies can also cause allergy, such as Cynodon dactylon (Chloridoideae) and Phragmites communis (Arundinoideae). C dactylon and P communis have not been included in the sweet grasses homologous group because of their low cross-reactivity with other grasses. The aims of this study were to investigate the profile of sensitization to C dactylon and P communis in patients sensitized to grasses and to analyze cross-reactivity between these 2 species and temperate grasses. Patients were skin prick tested with a grass mixture (GM). Specific IgE to GM, C dactylon, P communis, Cyn d 1, and Phl p 1 was measured by ImmunoCAP. A pool of sera was used for the immunoblot assays. Cross-reactivity was studied by ELISA and immunoblot inhibition. Thirty patients had sIgE to GM. Twenty-four (80%) had positive results for C dactylon, 27 (90%) for P communis, 22 (73.3%) for nCyn d 1, and 92.9% for rPhl p 1. Bands were detected in the 3 extracts by immunoblot. Inhibition of GM was not observed with C dactylon or P communis by immunoblot or ELISA inhibition. When C dactylon or P communis were used in the solid phase, GM produced almost complete inhibition. Eighty percent of patients sensitized to grasses were also sensitized to C dactylon and 90% were sensitized to P communis. Sensitization to these species seems to be induced by allergens different to those in sweet grasses.

  8. IgG immune responses to different proteins of Helicobacter Pylori as defined by immunoblot assay

    Directory of Open Access Journals (Sweden)

    Raeiszadeh M

    2000-09-01

    Full Text Available Helicobacter pylori (H.pylori is an etiologic factor for chronic gastritis and peptic ulcers. Serological testing of H.pylori infection is common in Iran, as other parts of the world. There are geographical variations in the humoral immune response to various H. pylori strains in different parts of the worl. We studied the immunogenic proteins of H.pylori by means of an Immunoblot assay with antigens of H.pylori strains isolated in Iran. Sera of 64 patients suffering from dyspepsia were analyzed to determine antibodlies which were good marker of infection and the antibody patterns associated with peptic ulcer.54 out of 64 dyspeptic patients were infected by H. pylori based on positive culture or positive results of both rapid urease test and direct examination. 14 out of fity-four had peptic ulcers and the rest were catagoriied as patients with non-ulcer dyspepsia. Some of them had multiple erosions in the gut or deodenum. Tweny –two major bands were identified by immunoblot. Of these, IgG antibodies against 10 protients, and they produced immunoreative bands at 14, 16, 22, 26, 32 , 32, 44, 87, 92, 120 Kda. Antibody patterns were not identical in the patients. The presence of at least one band at 14, 16, 22, 26, 32, 35Kda was the best marker of infection(sensitivity, 90% and specificity, 80% Major serological cross reactions were found at moderate molecular weight bands (50, 52, 54, 60, 66 KDa. The presence of at least one band at 14, 16, 22, 26, 32, 35Kda was the best marker of infection (sensitivity, 90% and specificity, 80%. Major serological crossreactions were found at moderate molerate molecular weight bands (50, 52, 54, 60, 66 KDa. The presence of antibodies to 120 Kda protein (Cag A and 87 Kda Protein (Vac A were not associated with the presence of peptic ulcers. These were in contradiction to results obtained across Europe and U.S but in agreement with Asian studies. However the presence of at least one band at either 32 or 35 Kda was

  9. Sensitization and allergy to Cannabis sativa leaves in a population of tomato (Lycopersicon esculentum)-sensitized patients.

    Science.gov (United States)

    de Larramendi, Carlos Hernando; Carnés, Jerónimo; García-Abujeta, José Luís; García-Endrino, Ana; Muñoz-Palomino, Elena; Huertas, Angel Julio; Fernández-Caldas, Enrique; Ferrer, Angel

    2008-01-01

    Cases of allergy to Cannabis sativa have occasionally been reported, but both the allergenic profile and eventual cross-reactivity pattern remain unknown. To analyze the allergenic profile of a population of patients from Spain sensitized to C. sativa and to characterize the C. sativa leaf extract. A total of 32 subjects were enrolled in the study: group A, 10 individuals sensitized to tomato, reporting reactions by contact or inhalation to Cannabis; group B, 14 individuals sensitized to tomato, without reactions to Cannabis; group C, 8 individuals not sensitized to tomato and without reactions to Cannabis. Sensitivity to Cannabis, tomato and peach peel, Platanus hybrida and Artemisia vulgaris pollen extracts was measured by skin tests and specific IgE. Individual immunoblots and inhibition experiments with a pool of sera were conducted. All tomato-sensitized subjects (and 1 negative) had positive skin tests to C. sativa leaves and hashish. Specific IgE to C. sativa and peach peel was more common than to tomato. Immunoblot experiments showed 2 prominent bands of 10 and 14 kDa and 2 weakly recognized bands of 30 and 45 kDa. Tomato, peach and A. vulgaris extracts inhibited most of the bands present in C. sativa. P. hybrida inhibited only the high-molecular-weight bands. Sensitization to C. sativa with or without symptoms is frequent among patients in Spain sensitized to tomato. C. sativa leaves are a potential allergenic source and their allergens may cross-react with other allergenic sources from plants (fruit peels and pollen). (c) 2008 S. Karger AG, Basel

  10. Diagnostic performance of a commercial immunoblot assay for myositis antibody testing.

    Science.gov (United States)

    Bundell, Chris; Rojana-Udomsart, Arada; Mastaglia, Frank; Hollingsworth, Peter; McLean-Tooke, Andrew

    2016-06-01

    The objective of this study was to establish a population based reference range for a commercial immunoblot assay detecting myositis specific autoantibodies (MSAs) and myositis associated autoantibodies (MAAs), and to assess the diagnostic performance of this reference range against the manufacturer's recommended ranges in a myositis patient cohort. A total of 124 patients from a myositis cohort and 197 healthy controls were serologically assessed using a commercial immunoblot containing eleven autoantigens (Jo-1, EJ, OJ, PL7, PL12, Mi-2, SRP, Ku, PMScl75, PMScl100 and Ro52) according to the manufacturer's instructions. Use of the manufacturer's reference ranges resulted in detection of MSAs in 19.4% of myositis patients and 9.1% of controls; MAAs were detected in 41.1% of myositis patients and 14.2% of controls. Reference values derived from the healthy control population resulted in significant differences in cut-off values for some autoantibodies, particularly Ro52 and PMScl75. Use of local reference ranges reduced detection of MSAs to 16.9% of myositis patients and 3% of healthy controls, with MAAs 23.4% of patients and 2% of healthy controls. Application of population based reference ranges resulted in significant differences in detection of MSAs and MAAs compared to the manufacturer's recommended ranges. Cut-off levels should be assessed to ensure suitability for the population tested. Copyright © 2016. Published by Elsevier B.V.

  11. Identification of antigenic proteins of setaria cervi by immunoblotting technique

    International Nuclear Information System (INIS)

    Kaushal, N.A.; Kaushal, D.C.; Ghatak, S.

    1987-01-01

    Identification and characterization of antigenic proteins of Setaria cervi (bovine filarial parasite) adults and microfilariae was done by immunoblotting technique using hyperimmune rabbit sera against S. cervi and Brugia malayi. The antigens recognized by these sera were detected by using 125 I protein-A followed by autoradiography. Fifteen different antigens were observed to be common between adult and microfilarial stages of the parasite. Some stage specific antigens were also identified. Many antigens of S. cervi adults and microfilariae were also recognized by rabbit anti-B.malayi serum showing the existence of common antigenic determinants between the bovine and human filarial parasites

  12. Electrophoretic analysis of proteins from Mycoplasma hominis strains detected by SDS-PAGE, two-dimensional gel electrophoresis and immunoblotting

    DEFF Research Database (Denmark)

    Andersen, H; Birkelund, Svend; Christiansen, Gunna

    1987-01-01

    The proteins of 14 strains of Mycoplasma hominis were compared by SDS-PAGE in gradient gels, by two-dimensional (2D) gel electrophoresis of extracts of 35S-labelled cells and by immunoblot analysis of cell proteins. The strains examined included the M. hominis type strain PG21 and 13 others...... isolated variously from genital tract, mouth, blood, upper urinary tract and a wound. These 14 strains shared 76-99% of proteins in SDS-gradient gel analysis and 41-72% in the 2D gels. As expected, the immunoblot analysis likewise revealed the existence of an extensive common protein pattern in M. hominis...

  13. Diagnostic accuracy of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for the detection of antibodies against Neospora caninum in milk from dairy cows.

    Science.gov (United States)

    Chatziprodromidou, I P; Apostolou, T

    2018-04-01

    The aim of the study was to estimate the sensitivity and specificity of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for detecting antibodies of Neospora caninum in dairy cows, in the absence of a gold standard. The study complies with STRADAS-paratuberculosis guidelines for reporting the accuracy of the test. We tried to apply Bayesian models that do not require conditional independence of the tests under evaluation, but as convergence problems appeared, we used Bayesian methodology, that does not assume conditional dependence of the tests. Informative prior probability distributions were constructed, based on scientific inputs regarding sensitivity and specificity of the IB test and the prevalence of disease in the studied populations. IB sensitivity and specificity were estimated to be 98.8% and 91.3%, respectively, while the respective estimates for ELISA were 60% and 96.7%. A sensitivity analysis, where modified prior probability distributions concerning IB diagnostic accuracy applied, showed a limited effect in posterior assessments. We concluded that ELISA can be used to screen the bulk milk and secondly, IB can be used whenever needed.

  14. Ma2 antibodies: an evaluation of commercially available detection methods.

    Science.gov (United States)

    Johannis, Wibke; Renno, Joerg H; Wielckens, Klaus; Voltz, Raymond

    2011-01-01

    Ma2 antibodies belong to the onconeuronal antibodies which define a "definite" paraneoplastic neurological syndrome (PNS). Because of the clinical relevance, use of two separate methods (indirect immunofluorescence technique--IFT--and immunoblot) is advocated; however, with an increasing number of commercially available assay systems, usually only one assay is performed. We compared IFT and three commercially available immunoblots (ravo Diagnostika, Euroimmun, Milenia Biotec) on sera from 35 patients with clinically suspected PNS. 17 were Ma2 antibody associated as defined by consensus result (showing positive reactivity in 2 assays), 18 were Ma2 antibody negative controls. Sensitivity/specificity for single assays were for IFT 94%/94%, for ravo Diagnostika PNS blot 88%/100%, for Euroimmun Neuronal Antigens Profile blot 100%/89%, and for Milenia Biotec MTR blot 94%/100%. Our data confirm, although all tests performed well, a combination of 2 independent assays is still advisable for Ma2 antibody detection in order to achieve higher sensitivity and specificity rates.

  15. Simultaneous identification of Trypanosoma cruzi surface and internal antigens reactive to different immunoglobulin classes (radio-immunoblotting)

    International Nuclear Information System (INIS)

    Stolf, A.M.S.; Umezawa, E.S.; Zingales, B.

    1990-01-01

    A radioactive Western blotting technique was developed by which the reactivity of Immunoglobulins (IGs) from different classes to both membrane radiolabelled and internal parasite antigens is simultaneously identified. The method includes radioiodination of parasites, polypeptide fractionation by SDS-PAGE, Western-blot transfer and autoradiography of the immunoblots developed with anti-Igs conjugates labelled with enzymes. The analysis is then performed by the comparison of common bands on the autoradiograms and the respective substrate stained nitrocellulose blots. This technique was used to analyse. T.cruzi trypomastigote surface labelled antigens reactive to IgM, IgA and IgC specific antibodies. A different pattern of reactivity with acute Chagas disease patients sera was thus obtained. (author)

  16. ‘True’ antimitochondrial antibody-negative primary biliary cirrhosis, low sensitivity of the routine assays, or both?

    Science.gov (United States)

    MURATORI, P; MURATORI, L; GERSHWIN, M E; CZAJA, A J; PAPPAS, G; MACCARIELLO, S; GRANITO, A; CASSANI, F; LORIA, P; LENZI, M; BIANCHI, F B

    2004-01-01

    Anti-mitochondrial antibody (AMA) is considered the serological hallmark of primary biliary cirrhosis (PBC), but may be missing in a proportion of these patients. We assessed sensitivity and specificity of the currently available techniques for AMA detection in a large series of PBC patients and controls, and analysed their clinical and immunological features according to the AMA status. By indirect immunofluorescence on rat tissue sections and HEp-2 cells, Western immunoblot with bovine submitochondrial particles, and two ELISAs with AMA-specific recombinant proteins, we evaluated the presence of AMA in 127 PBC patients, 166 patients with type 1 autoimmune hepatitis and 100 with non alcoholic fatty liver disease. In PBC patients Western immunoblot detects AMA significantly more often than indirect immunofluorescence on HEp-2 cells (85% versus 72%, P = 0·02) or rodent tissue sections (71%, P = 0·01); both ELISAs are only slightly less sensitive than Western immunoblot (81% and 78%). Ten patients with non alcoholic fatty liver disease were AMA-positive by indirect immunofluorescence, but none recognized AMA-specific epitopes in Western immunoblot or in ELISAs. Twelve patients with type 1 autoimmune hepatitis were AMA-positive by indirect immunofluorescence, but only 6 (3·6%) reacted by Western immunoblot and ELISAs. Western immunoblot or ELISA should be regarded as first-line assay for the detection of AMA. Up to 15% of PBC patients are consistently AMA-negative, yet they share the same clinical, biochemical and histological features of AMA-positive PBC. Detection of AMA in type 1 autoimmune hepatitis might identify a subset of patients at risk of developing a hepatitic/cholestatic syndrome. PMID:14678277

  17. Comparative immunoblot analysis with 10 different, partially overlapping recombinant fusion proteins derived from 5 different cytomegalovirus proteins

    NARCIS (Netherlands)

    van Zanten, J.; LAZZAROTTO, T; CAMPISI, B; VORNHAGEN, R; JAHN, G; LANDINI, MP; The, T. Hauw

    Ten fusion proteins derived from five various CMV encoded proteins were used for the detection of specific antibody response by immunoblot technique in sera from renal transplant recipients. The fusion proteins were derived from the following CMV specific proteins: the assembly protein ppUL80a with

  18. [Fundamental evaluation of apolipoprotein B-48 by chemiluminescence enzyme immunoassay--identification of apolipoprotein B-48 with immunoblotting].

    Science.gov (United States)

    Sato, Itsuko; Fujioka, Yoshio; Hayashi, Fujio; Mukai, Masahiko; Kawano, Seiji; Ishikawa, Yuichi; Yamashita, Shizuya; Kumagai, Shunichi

    2007-06-01

    Apolipoprotein B-48 (apo B-48) is a constituent of chylomicrons and chylomicron remnants, and its fasting concentration has been reported to be a marker of postprandial hyperlipidemia, which is thought to be a risk factor of atherosclerosis. We evaluated the serum apo B-48 concentrations by chemiluminescence enzyme immunoassay (CLEIA), which was recently introduced as Lumipulse f fully automated immunosaasy analyzer by Fujirebio Inc (Tokyo, Japan), and performed immunoblotting on agarose gel electrophoresis with anti-apo B-48 antibody. Apo B-48 assay was intra-assay reproducible (CVs: 1.9-3.1%) and inter-assay reproducible (CVs: 2.2-4.4%). The assay range for apo B-48 was from 0.2 to 40.0 microg/ml. The effects of interfering substances such as free/conjugated birirubin, hemoglobin, Intrafat, ascorbic acid and rheumatoid factor were negligible. For storage, it was preferable to freeze, and to avoid frozen-thaw process as much as possible. Anti-apo B-48 antibody was reactive over a wide range from origin to the position of very-low-density lipoproteins in immunoblotting after agarose gel electrophoresis. Apo B-48 measurement by CLEIA was feasible to clinical use for the assessment of lipoprotein metabolism.

  19. Nonelectrophoretic bidirectional transfer of a single SDS-PAGE gel with multiple antigens to obtain 12 immunoblots.

    Science.gov (United States)

    Kurien, Biji T; Scofield, R Hal

    2009-01-01

    Protein blotting is an invaluable technique in immunology to detect and characterize proteins of low abundance. Proteins resolved on sodium dodecyl sulfate (SDS) polyacrylamide gels are normally transferred electrophoretically to adsorbent membranes such as nitrocellulose or polyvinylidene diflouride membranes. Here, we describe the nonelectrophroretic transfer of the Ro 60 (or SSA) autoantigen, 220- and 240-kD spectrin antigens, and prestained molecular weight standards from SDS polyacrylamide gels to obtain up to 12 immunoblots from a single gel and multiple sera.

  20. Frequency of serum anti-cysticercus antibodies in the population of a rural Brazilian community (Cássia dos Coqueiros, SP determined by ELISA and immunoblotting using Taenia crassiceps antigens

    Directory of Open Access Journals (Sweden)

    BRAGAZZA Lúcia M.

    2002-01-01

    Full Text Available Considering the impact of cysticercosis on public health, especially the neurologic form of the disease, neurocysticercosis (NC, we studied the frequency of positivity of anti-Taenia solium cysticercus antibodies in serum samples from 1,863 inhabitants of Cássia dos Coqueiros, SP, a municipal district located 80 km from Ribeirão Preto, an area considered endemic for cysticercosis. The 1,863 samples were tested by enzyme linked immunosorbent assay (ELISA using an antigenic extract from Taenia crassiceps vesicular fluid (Tcra. The reactive and inconclusive ELISA samples were tested by immunoblotting. Of the 459 samples submitted to immunoblotting, 40 were strongly immunoreactive to the immunodominant 18 and 14 kD peptides. Considering the use of immunoblotting as confirmatory due to its high specificity, the anti-cysticercus serum prevalence in this population was 2.1%.

  1. Assessment of Intrathecal Free Light Chain Synthesis: Comparison of Different Quantitative Methods with the Detection of Oligoclonal Free Light Chains by Isoelectric Focusing and Affinity-Mediated Immunoblotting.

    Science.gov (United States)

    Zeman, David; Kušnierová, Pavlína; Švagera, Zdeněk; Všianský, František; Byrtusová, Monika; Hradílek, Pavel; Kurková, Barbora; Zapletalová, Olga; Bartoš, Vladimír

    2016-01-01

    We aimed to compare various methods for free light chain (fLC) quantitation in cerebrospinal fluid (CSF) and serum and to determine whether quantitative CSF measurements could reliably predict intrathecal fLC synthesis. In addition, we wished to determine the relationship between free kappa and free lambda light chain concentrations in CSF and serum in various disease groups. We analysed 166 paired CSF and serum samples by at least one of the following methods: turbidimetry (Freelite™, SPAPLUS), nephelometry (N Latex FLC™, BN ProSpec), and two different (commercially available and in-house developed) sandwich ELISAs. The results were compared with oligoclonal fLC detected by affinity-mediated immunoblotting after isoelectric focusing. Although the correlations between quantitative methods were good, both proportional and systematic differences were discerned. However, no major differences were observed in the prediction of positive oligoclonal fLC test. Surprisingly, CSF free kappa/free lambda light chain ratios were lower than those in serum in about 75% of samples with negative oligoclonal fLC test. In about a half of patients with multiple sclerosis and clinically isolated syndrome, profoundly increased free kappa/free lambda light chain ratios were found in the CSF. Our results show that using appropriate method-specific cut-offs, different methods of CSF fLC quantitation can be used for the prediction of intrathecal fLC synthesis. The reason for unexpectedly low free kappa/free lambda light chain ratios in normal CSFs remains to be elucidated. Whereas CSF free kappa light chain concentration is increased in most patients with multiple sclerosis and clinically isolated syndrome, CSF free lambda light chain values show large interindividual variability in these patients and should be investigated further for possible immunopathological and prognostic significance.

  2. Identification of snake venom allergens by two-dimensional electrophoresis followed by immunoblotting.

    Science.gov (United States)

    Hu, Yujing; Yang, Liming; Yang, Haiwei; He, Shaoheng; Wei, Ji-Fu

    2017-01-01

    This allergic reaction to snake venom was described to occur in patients after recurrent exposure through bites in amateur and professional snake handlers, which might be underestimated and contribute to fatal snakebites in victim, independently from the toxicity of the venom itself. Few allergens were identified from snake venoms by normal SDS-PAGE, which cannot separate the snake venom completely. In the present study, we identified nine potential allergens by two-dimensional (2D) electrophoresis followed by immunoblotting (named as allergenomics) in Protobothrops mucrosquamatus venom. By multidimensional liquid chromatography-ion trap mass spectrometry (MDLC-ESI-LTQ-MS/MS) analysis, six allergens showed sequence similarity to snake venom serine proteinases. Other allergens showed sequence similarity to snake venom metalloproteinase. These allergic reactions to snake venom allergens might contribute to fatal snakebites in victim, independently. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Multiple predictor smoothing methods for sensitivity analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Helton, Jon Craig; Storlie, Curtis B.

    2006-08-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described: (1) locally weighted regression (LOESS), (2) additive models, (3) projection pursuit regression, and (4) recursive partitioning regression. The indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present.

  4. Multiple predictor smoothing methods for sensitivity analysis

    International Nuclear Information System (INIS)

    Helton, Jon Craig; Storlie, Curtis B.

    2006-01-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described: (1) locally weighted regression (LOESS), (2) additive models, (3) projection pursuit regression, and (4) recursive partitioning regression. The indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present

  5. An ESDIRK Method with Sensitivity Analysis Capabilities

    DEFF Research Database (Denmark)

    Kristensen, Morten Rode; Jørgensen, John Bagterp; Thomsen, Per Grove

    2004-01-01

    of the sensitivity equations. A key feature is the reuse of information already computed for the state integration, hereby minimizing the extra effort required for sensitivity integration. Through case studies the new algorithm is compared to an extrapolation method and to the more established BDF based approaches...

  6. A New Computationally Frugal Method For Sensitivity Analysis Of Environmental Models

    Science.gov (United States)

    Rakovec, O.; Hill, M. C.; Clark, M. P.; Weerts, A.; Teuling, R.; Borgonovo, E.; Uijlenhoet, R.

    2013-12-01

    Effective and efficient parameter sensitivity analysis methods are crucial to understand the behaviour of complex environmental models and use of models in risk assessment. This paper proposes a new computationally frugal method for analyzing parameter sensitivity: the Distributed Evaluation of Local Sensitivity Analysis (DELSA). The DELSA method can be considered a hybrid of local and global methods, and focuses explicitly on multiscale evaluation of parameter sensitivity across the parameter space. Results of the DELSA method are compared with the popular global, variance-based Sobol' method and the delta method. We assess the parameter sensitivity of both (1) a simple non-linear reservoir model with only two parameters, and (2) five different "bucket-style" hydrologic models applied to a medium-sized catchment (200 km2) in the Belgian Ardennes. Results show that in both the synthetic and real-world examples, the global Sobol' method and the DELSA method provide similar sensitivities, with the DELSA method providing more detailed insight at much lower computational cost. The ability to understand how sensitivity measures vary through parameter space with modest computational requirements provides exciting new opportunities.

  7. Recombinant immunoblot assay reaction patterns and hepatitis C virus RNA in blood donors and non-A, non-B hepatitis patients

    NARCIS (Netherlands)

    Bresters, D.; Zaaijer, H. L.; Cuypers, H. T.; Reesink, H. W.; Winkel, I. N.; van Exel-Oehlers, P. J.; van Drimmelen, A. A.; Jansen, P. L.; van der Poel, C. L.; Lelie, P. N.

    1993-01-01

    To establish the value of the second-generation recombinant immunoblot assay (RIBA-2) and cDNA polymerase chain reaction (cDNA PCR) for confirmation of hepatitis C virus (HCV) infection, anti-HCV reaction patterns and the presence of HCV RNA were examined in 610 blood donors and 255 non-A, non-B

  8. A general first-order global sensitivity analysis method

    International Nuclear Information System (INIS)

    Xu Chonggang; Gertner, George Zdzislaw

    2008-01-01

    Fourier amplitude sensitivity test (FAST) is one of the most popular global sensitivity analysis techniques. The main mechanism of FAST is to assign each parameter with a characteristic frequency through a search function. Then, for a specific parameter, the variance contribution can be singled out of the model output by the characteristic frequency. Although FAST has been widely applied, there are two limitations: (1) the aliasing effect among parameters by using integer characteristic frequencies and (2) the suitability for only models with independent parameters. In this paper, we synthesize the improvement to overcome the aliasing effect limitation [Tarantola S, Gatelli D, Mara TA. Random balance designs for the estimation of first order global sensitivity indices. Reliab Eng Syst Safety 2006; 91(6):717-27] and the improvement to overcome the independence limitation [Xu C, Gertner G. Extending a global sensitivity analysis technique to models with correlated parameters. Comput Stat Data Anal 2007, accepted for publication]. In this way, FAST can be a general first-order global sensitivity analysis method for linear/nonlinear models with as many correlated/uncorrelated parameters as the user specifies. We apply the general FAST to four test cases with correlated parameters. The results show that the sensitivity indices derived by the general FAST are in good agreement with the sensitivity indices derived by the correlation ratio method, which is a non-parametric method for models with correlated parameters

  9. Application of Stochastic Sensitivity Analysis to Integrated Force Method

    Directory of Open Access Journals (Sweden)

    X. F. Wei

    2012-01-01

    Full Text Available As a new formulation in structural analysis, Integrated Force Method has been successfully applied to many structures for civil, mechanical, and aerospace engineering due to the accurate estimate of forces in computation. Right now, it is being further extended to the probabilistic domain. For the assessment of uncertainty effect in system optimization and identification, the probabilistic sensitivity analysis of IFM was further investigated in this study. A set of stochastic sensitivity analysis formulation of Integrated Force Method was developed using the perturbation method. Numerical examples are presented to illustrate its application. Its efficiency and accuracy were also substantiated with direct Monte Carlo simulations and the reliability-based sensitivity method. The numerical algorithm was shown to be readily adaptable to the existing program since the models of stochastic finite element and stochastic design sensitivity are almost identical.

  10. Method-independent, Computationally Frugal Convergence Testing for Sensitivity Analysis Techniques

    Science.gov (United States)

    Mai, J.; Tolson, B.

    2017-12-01

    The increasing complexity and runtime of environmental models lead to the current situation that the calibration of all model parameters or the estimation of all of their uncertainty is often computationally infeasible. Hence, techniques to determine the sensitivity of model parameters are used to identify most important parameters. All subsequent model calibrations or uncertainty estimation procedures focus then only on these subsets of parameters and are hence less computational demanding. While the examination of the convergence of calibration and uncertainty methods is state-of-the-art, the convergence of the sensitivity methods is usually not checked. If any, bootstrapping of the sensitivity results is used to determine the reliability of the estimated indexes. Bootstrapping, however, might as well become computationally expensive in case of large model outputs and a high number of bootstraps. We, therefore, present a Model Variable Augmentation (MVA) approach to check the convergence of sensitivity indexes without performing any additional model run. This technique is method- and model-independent. It can be applied either during the sensitivity analysis (SA) or afterwards. The latter case enables the checking of already processed sensitivity indexes. To demonstrate the method's independency of the convergence testing method, we applied it to two widely used, global SA methods: the screening method known as Morris method or Elementary Effects (Morris 1991) and the variance-based Sobol' method (Solbol' 1993). The new convergence testing method is first scrutinized using 12 analytical benchmark functions (Cuntz & Mai et al. 2015) where the true indexes of aforementioned three methods are known. This proof of principle shows that the method reliably determines the uncertainty of the SA results when different budgets are used for the SA. The results show that the new frugal method is able to test the convergence and therefore the reliability of SA results in an

  11. Temperature sensitive surfaces and methods of making same

    Science.gov (United States)

    Liang, Liang [Richland, WA; Rieke, Peter C [Pasco, WA; Alford, Kentin L [Pasco, WA

    2002-09-10

    Poly-n-isopropylacrylamide surface coatings demonstrate the useful property of being able to switch charateristics depending upon temperature. More specifically, these coatings switch from being hydrophilic at low temperature to hydrophobic at high temperature. Research has been conducted for many years to better characterize and control the properties of temperature sensitive coatings. The present invention provides novel temperature sensitive coatings on articles and novel methods of making temperature sensitive coatings that are disposed on the surfaces of various articles. These novel coatings contain the reaction products of n-isopropylacrylamide and are characterized by their properties such as advancing contact angles. Numerous other characteristics such as coating thickness, surface roughness, and hydrophilic-to-hydrophobic transition temperatures are also described. The present invention includes articles having temperature-sensitve coatings with improved properties as well as improved methods for forming temperature sensitive coatings.

  12. Patrón de immunoblotting y niveles de anticuerpos anti-Toxoplasma gondii en suero y humor acuoso de pacientes con lesiones de toxoplasmosis ocular

    Directory of Open Access Journals (Sweden)

    Morella Bouchard Pereira

    2014-07-01

    parasite antigen recognition pattern by immunoblotting (IB in positive serology patients with or without ocular toxoplasmosis lesions. Serum and aqueous humor samples were simultaneously collected from 26 patients: a group of patients with ocular toxoplasmosis retinal lesions in active and inactive phase (n=17 and a control group that required ocular surgery because of cataract (n=9. IgM and IgG level tests were determined by immunocapture and indirect ELISA respectively, Radial immunodiffusion and immunoblotting. Radial immunodiffusion was used for quantification of total IgG, CGW > 2 indicated the local specific antibodies production in 12/17 patients, whereas in the control group none was observed. The GWC showed 71% sensitivity and 100% specificity. By IB test, the detection of two bands in aquous humor indicated a local specific antibodies production which were observed in 11/17 patients and 1/9 controls showing 65% sensibility and 89% specificity. By considering both tests the sensibility increased to 73% and the specificity decreased to 89%. In conclusion, the IB technique can be used as a complementary test to GWC, especially in patients with atypical lesions that lead to unclear clinical diagnosis

  13. A laser ablation ICP-MS based method for multiplexed immunoblot analysis

    DEFF Research Database (Denmark)

    de Bang, Thomas Christian; Petersen, Jørgen; Pedas, Pai Rosager

    2015-01-01

    developed a multiplexed antibody-based assay and analysed selected PSII subunits in barley (Hordeum vulgare L.). A selection of antibodies were labelled with specific lanthanides and immunoreacted with thylakoids exposed to Mn deficiency after western blotting. Subsequently, western blot membranes were...... analysed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), which allowed selective and relative quantitative analysis via the different lanthanides. The method was evaluated against established liquid chromatography electrospray ionization tandem mass spectrometry (LC...... by more than one technique. The developed method enables a higher number of proteins to be multiplexed in comparison to existing immunoassays. Furthermore, multiplexed protein analysis by LA-ICP-MS provides an analytical platform with high throughput appropriate for screening large collections of plants....

  14. Comparing sensitivity analysis methods to advance lumped watershed model identification and evaluation

    Directory of Open Access Journals (Sweden)

    Y. Tang

    2007-01-01

    Full Text Available This study seeks to identify sensitivity tools that will advance our understanding of lumped hydrologic models for the purposes of model improvement, calibration efficiency and improved measurement schemes. Four sensitivity analysis methods were tested: (1 local analysis using parameter estimation software (PEST, (2 regional sensitivity analysis (RSA, (3 analysis of variance (ANOVA, and (4 Sobol's method. The methods' relative efficiencies and effectiveness have been analyzed and compared. These four sensitivity methods were applied to the lumped Sacramento soil moisture accounting model (SAC-SMA coupled with SNOW-17. Results from this study characterize model sensitivities for two medium sized watersheds within the Juniata River Basin in Pennsylvania, USA. Comparative results for the 4 sensitivity methods are presented for a 3-year time series with 1 h, 6 h, and 24 h time intervals. The results of this study show that model parameter sensitivities are heavily impacted by the choice of analysis method as well as the model time interval. Differences between the two adjacent watersheds also suggest strong influences of local physical characteristics on the sensitivity methods' results. This study also contributes a comprehensive assessment of the repeatability, robustness, efficiency, and ease-of-implementation of the four sensitivity methods. Overall ANOVA and Sobol's method were shown to be superior to RSA and PEST. Relative to one another, ANOVA has reduced computational requirements and Sobol's method yielded more robust sensitivity rankings.

  15. Resonance-induced sensitivity enhancement method for conductivity sensors

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Shih, Chi-yuan (Inventor); Li, Wei (Inventor); Zheng, Siyang (Inventor)

    2009-01-01

    Methods and systems for improving the sensitivity of a variety of conductivity sensing devices, in particular capacitively-coupled contactless conductivity detectors. A parallel inductor is added to the conductivity sensor. The sensor with the parallel inductor is operated at a resonant frequency of the equivalent circuit model. At the resonant frequency, parasitic capacitances that are either in series or in parallel with the conductance (and possibly a series resistance) is substantially removed from the equivalent circuit, leaving a purely resistive impedance. An appreciably higher sensor sensitivity results. Experimental verification shows that sensitivity improvements of the order of 10,000-fold are possible. Examples of detecting particulates with high precision by application of the apparatus and methods of operation are described.

  16. NK sensitivity of neuroblastoma cells determined by a highly sensitive coupled luminescent method

    International Nuclear Information System (INIS)

    Ogbomo, Henry; Hahn, Anke; Geiler, Janina; Michaelis, Martin; Doerr, Hans Wilhelm; Cinatl, Jindrich

    2006-01-01

    The measurement of natural killer (NK) cells toxicity against tumor or virus-infected cells especially in cases with small blood samples requires highly sensitive methods. Here, a coupled luminescent method (CLM) based on glyceraldehyde-3-phosphate dehydrogenase release from injured target cells was used to evaluate the cytotoxicity of interleukin-2 activated NK cells against neuroblastoma cell lines. In contrast to most other methods, CLM does not require the pretreatment of target cells with labeling substances which could be toxic or radioactive. The effective killing of tumor cells was achieved by low effector/target ratios ranging from 0.5:1 to 4:1. CLM provides highly sensitive, safe, and fast procedure for measurement of NK cell activity with small blood samples such as those obtained from pediatric patients

  17. Sensitivity analysis methods and a biosphere test case implemented in EIKOS

    Energy Technology Data Exchange (ETDEWEB)

    Ekstroem, P.A.; Broed, R. [Facilia AB, Stockholm, (Sweden)

    2006-05-15

    Computer-based models can be used to approximate real life processes. These models are usually based on mathematical equations, which are dependent on several variables. The predictive capability of models is therefore limited by the uncertainty in the value of these. Sensitivity analysis is used to apportion the relative importance each uncertain input parameter has on the output variation. Sensitivity analysis is therefore an essential tool in simulation modelling and for performing risk assessments. Simple sensitivity analysis techniques based on fitting the output to a linear equation are often used, for example correlation or linear regression coefficients. These methods work well for linear models, but for non-linear models their sensitivity estimations are not accurate. Usually models of complex natural systems are non-linear. Within the scope of this work, various sensitivity analysis methods, which can cope with linear, non-linear, as well as non-monotone problems, have been implemented, in a software package, EIKOS, written in Matlab language. The following sensitivity analysis methods are supported by EIKOS: Pearson product moment correlation coefficient (CC), Spearman Rank Correlation Coefficient (RCC), Partial (Rank) Correlation Coefficients (PCC), Standardized (Rank) Regression Coefficients (SRC), Sobol' method, Jansen's alternative, Extended Fourier Amplitude Sensitivity Test (EFAST) as well as the classical FAST method and the Smirnov and the Cramer-von Mises tests. A graphical user interface has also been developed, from which the user easily can load or call the model and perform a sensitivity analysis as well as uncertainty analysis. The implemented sensitivity analysis methods has been benchmarked with well-known test functions and compared with other sensitivity analysis software, with successful results. An illustration of the applicability of EIKOS is added to the report. The test case used is a landscape model consisting of several

  18. Sensitivity analysis methods and a biosphere test case implemented in EIKOS

    International Nuclear Information System (INIS)

    Ekstroem, P.A.; Broed, R.

    2006-05-01

    Computer-based models can be used to approximate real life processes. These models are usually based on mathematical equations, which are dependent on several variables. The predictive capability of models is therefore limited by the uncertainty in the value of these. Sensitivity analysis is used to apportion the relative importance each uncertain input parameter has on the output variation. Sensitivity analysis is therefore an essential tool in simulation modelling and for performing risk assessments. Simple sensitivity analysis techniques based on fitting the output to a linear equation are often used, for example correlation or linear regression coefficients. These methods work well for linear models, but for non-linear models their sensitivity estimations are not accurate. Usually models of complex natural systems are non-linear. Within the scope of this work, various sensitivity analysis methods, which can cope with linear, non-linear, as well as non-monotone problems, have been implemented, in a software package, EIKOS, written in Matlab language. The following sensitivity analysis methods are supported by EIKOS: Pearson product moment correlation coefficient (CC), Spearman Rank Correlation Coefficient (RCC), Partial (Rank) Correlation Coefficients (PCC), Standardized (Rank) Regression Coefficients (SRC), Sobol' method, Jansen's alternative, Extended Fourier Amplitude Sensitivity Test (EFAST) as well as the classical FAST method and the Smirnov and the Cramer-von Mises tests. A graphical user interface has also been developed, from which the user easily can load or call the model and perform a sensitivity analysis as well as uncertainty analysis. The implemented sensitivity analysis methods has been benchmarked with well-known test functions and compared with other sensitivity analysis software, with successful results. An illustration of the applicability of EIKOS is added to the report. The test case used is a landscape model consisting of several linked

  19. Sensitivity analysis of infectious disease models: methods, advances and their application

    Science.gov (United States)

    Wu, Jianyong; Dhingra, Radhika; Gambhir, Manoj; Remais, Justin V.

    2013-01-01

    Sensitivity analysis (SA) can aid in identifying influential model parameters and optimizing model structure, yet infectious disease modelling has yet to adopt advanced SA techniques that are capable of providing considerable insights over traditional methods. We investigate five global SA methods—scatter plots, the Morris and Sobol’ methods, Latin hypercube sampling-partial rank correlation coefficient and the sensitivity heat map method—and detail their relative merits and pitfalls when applied to a microparasite (cholera) and macroparasite (schistosomaisis) transmission model. The methods investigated yielded similar results with respect to identifying influential parameters, but offered specific insights that vary by method. The classical methods differed in their ability to provide information on the quantitative relationship between parameters and model output, particularly over time. The heat map approach provides information about the group sensitivity of all model state variables, and the parameter sensitivity spectrum obtained using this method reveals the sensitivity of all state variables to each parameter over the course of the simulation period, especially valuable for expressing the dynamic sensitivity of a microparasite epidemic model to its parameters. A summary comparison is presented to aid infectious disease modellers in selecting appropriate methods, with the goal of improving model performance and design. PMID:23864497

  20. Method of characteristics - Based sensitivity calculations for international PWR benchmark

    International Nuclear Information System (INIS)

    Suslov, I. R.; Tormyshev, I. V.; Komlev, O. G.

    2013-01-01

    Method to calculate sensitivity of fractional-linear neutron flux functionals to transport equation coefficients is proposed. Implementation of the method on the basis of MOC code MCCG3D is developed. Sensitivity calculations for fission intensity for international PWR benchmark are performed. (authors)

  1. Improved sensitivity testing of explosives using transformed Up-Down methods

    International Nuclear Information System (INIS)

    Brown, Geoffrey W

    2014-01-01

    Sensitivity tests provide data that help establish guidelines for the safe handling of explosives. Any sensitivity test is based on assumptions to simplify the method or reduce the number of individual sample evaluations. Two common assumptions that are not typically checked after testing are 1) explosive response follows a normal distribution as a function of the applied stimulus levels and 2) the chosen test level spacing is close to the standard deviation of the explosive response function (for Bruceton Up-Down testing for example). These assumptions and other limitations of traditional explosive sensitivity testing can be addressed using Transformed Up-Down (TUD) test methods. TUD methods have been developed extensively for psychometric testing over the past 50 years and generally use multiple tests at a given level to determine how to adjust the applied stimulus. In the context of explosive sensitivity we can use TUD methods that concentrate testing around useful probability levels. Here, these methods are explained and compared to Bruceton Up-Down testing using computer simulation. The results show that the TUD methods are more useful for many cases but that they do require more tests as a consequence. For non-normal distributions, however, the TUD methods may be the only accurate assessment method.

  2. Exploring Intercultural Sensitivity in Early Adolescence: A Mixed Methods Study

    Science.gov (United States)

    Mellizo, Jennifer M.

    2017-01-01

    The purpose of this mixed methods study was to explore levels of intercultural sensitivity in a sample of fourth to eighth grade students in the United States (n = 162). "Intercultural sensitivity" was conceptualised through Bennett's Developmental Model of Sensitivity, and assessed through the Adapted Intercultural Sensitivity Index.…

  3. Are LOD and LOQ Reliable Parameters for Sensitivity Evaluation of Spectroscopic Methods?

    Science.gov (United States)

    Ershadi, Saba; Shayanfar, Ali

    2018-03-22

    The limit of detection (LOD) and the limit of quantification (LOQ) are common parameters to assess the sensitivity of analytical methods. In this study, the LOD and LOQ of previously reported terbium sensitized analysis methods were calculated by different methods, and the results were compared with sensitivity parameters [lower limit of quantification (LLOQ)] of U.S. Food and Drug Administration guidelines. The details of the calibration curve and standard deviation of blank samples of three different terbium-sensitized luminescence methods for the quantification of mycophenolic acid, enrofloxacin, and silibinin were used for the calculation of LOD and LOQ. A comparison of LOD and LOQ values calculated by various methods and LLOQ shows a considerable difference. The significant difference of the calculated LOD and LOQ with various methods and LLOQ should be considered in the sensitivity evaluation of spectroscopic methods.

  4. [Research on medical speciality of traditional Chinese medicines using dot-immunoblotting method based on polyclonal antibody prepared from traditional Chinese medicines with hot/cold nature].

    Science.gov (United States)

    Wang, Houwei; Dou, Yanling; Tian, Jingzhen; Li, Feng; Wang, Shijun; Wang, Zhenguo

    2009-02-01

    with control antigen regularly varied with the alteration of medicine nature. The more similarity degree of the tested medicine to control antigen was smaller, the more distance of the tested medicine to control antigen was further. Dot immunoblotting was a practical and effective new method in researching the substantial foundation of the medical speciality of Chinese traditional medicines.

  5. Sensitivity Analysis of Structures by Virtual Distortion Method

    DEFF Research Database (Denmark)

    Gierlinski, J.T.; Holnicki-Szulc, J.; Sørensen, John Dalsgaard

    1991-01-01

    are used in structural optimization, see Haftka [4]. The recently developed Virtual Distortion Method (VDM) is a numerical technique which offers an efficient approach to calculation of the sensitivity derivatives. This method has been orginally applied to structural remodelling and collapse analysis, see...

  6. Fluorimetry as a Simple and Sensitive Method for Determination of Catalase

    Directory of Open Access Journals (Sweden)

    Mehdi Hedayati

    2014-02-01

    Full Text Available Background: Catalase enzyme plays an important role in the anti-oxidation defense of body so it is important to measure its activity. Nowadays catalase activity measurement is performed by expensive imported kits in various scientific fields. The purpose of this study was to design a sensitive fluorimetry method for measuring catalase activity with improved sensitivity, accuracy and speed. Materials and Methods: In this study, the reaction of hydrogen peroxide with peroxidase (as a reaction accelerator was used in fluorimetry for catalase activity measuring in serum samples in order to increase the sensitivity of the assay. The sensitivity and intra- and inter-assay accuracy, verification test, recovery and parallelism tests, comparison method and correlation and coherence investigation methods were also performed. In order to increase the accuracy and speed of reading, the assay was performed in microplates and reading was done in fluorimetry plates. Results: The percentage of intra- and inter-assay variation coefficients were measured 3.8- 6.6 % and 4.1-7.3%, respectively. Comparison of the results of mentioned method for 50 serum samples with common colorimetric method showed a good correlation (0.917. In assessing the accuracy, the recovery percent was obtained 91% to 107%. The test sensitivity was measured 0.02 IU/ml. Conclusion: The fluorimetry method by microplate reading has a sufficient precision, accuracy and efficiency for catalase activity measuring as well as speed of measurement. Thus it can be an alternative method to conventional imported colorimetric methods.

  7. Imunoblot como teste suplementar para detecção de anticorpos contra o vírus da hepatite C em doadores de sangue Immunoblot as a supplemental test to detect antibodies to hepatitis C virus in blood donors

    Directory of Open Access Journals (Sweden)

    Francisco José Dutra Souto

    2002-02-01

    Full Text Available Testes suplementares para melhorar a especificidade do anti-VHC por ELISA nos bancos de sangue não são oficialmente recomendados no Brasil. No intuito de avaliar a taxa de falso-positivos, 70 doadores com transaminases normais e anti-VHC por ELISA foram submetidos a imunoblot de 3ª geração no Hemocentro de Mato Grosso, que não dispõe da técnica da reação de cadeia de polimerase. O teste confirmou o anti-VHC em 44 (62,9%, sendo negativo em 22 (31,4% e indeterminado em 4 (5,7%. Confirmação pelo imunoblot ajuda a identificar os testes ELISA que são falso-positivos, tranqüilizando o grande contingente de doadores nessa situação e separando os que necessitam de acompanhamento médico. Com esse objetivo, sugere-se que o imunoblot poderia ser útil nos bancos de sangue brasileiros que não contam com técnicas de Biologia Molecular.Supplemental tests using Immunoblot are recommended to improve specificity of anti-HCV by ELISA. In Brazil immunoblot is not officially recommended. Aiming to identify EIA false-positive rate 70 positive EIA anti-HCV blood donors were submitted to 3rd generation immunoblot at Hemocentro of Mato Grosso State where polymerase chain reaction tests are not performed. There were 44 (62.9% immunoblot-positive, 22 (31.4% negative and 4 (5.7% indeterminate. Anti-HCV immunoblot can distinguish blood donors with false-positive ELISA from those who need medical assessment. Our data suggest that immunoblot could be useful in Brazilian blood banks where molecular biology tests are not available.

  8. Multiple predictor smoothing methods for sensitivity analysis: Example results

    International Nuclear Information System (INIS)

    Storlie, Curtis B.; Helton, Jon C.

    2008-01-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described in the first part of this presentation: (i) locally weighted regression (LOESS), (ii) additive models, (iii) projection pursuit regression, and (iv) recursive partitioning regression. In this, the second and concluding part of the presentation, the indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present

  9. Detection of toxoplasma gondii antigens in sera from experimentally infected mice

    International Nuclear Information System (INIS)

    Shojaee, S.; Keshavarz, H.; Rezaian, M.; Mohebali, M.

    2007-01-01

    Detection of Toxoplasma antigen in serum of mice by Immunoblotting. strain. IgG isolated from rabbits that were immunized with T. gondii Immunoblotting was performed to detect T. gondii antigens in sera of mice. Serum samples from mice experimentally infected with T. gondii RH strain. The value of Immunoblotting in diagnosis of toxoplasmosis in acute stage of infection. The antigen bands detected in serum sample of mice were experimentally infected with T. gondii tachyzoite in immunoblotting. Six bands demonstrated on seventh post infection day six bands were identified. Similarly on sixth day four bands, on day five three bands and on fourth post infection day two bands were identified. No band was detected in control group sera. Immunoblotting is a sensitive method for diagnosis of acute stage of toxoplasmosis. (author)

  10. SCALE-6 Sensitivity/Uncertainty Methods and Covariance Data

    International Nuclear Information System (INIS)

    Williams, Mark L.; Rearden, Bradley T.

    2008-01-01

    Computational methods and data used for sensitivity and uncertainty analysis within the SCALE nuclear analysis code system are presented. The methodology used to calculate sensitivity coefficients and similarity coefficients and to perform nuclear data adjustment is discussed. A description is provided of the SCALE-6 covariance library based on ENDF/B-VII and other nuclear data evaluations, supplemented by 'low-fidelity' approximate covariances. SCALE (Standardized Computer Analyses for Licensing Evaluation) is a modular code system developed by Oak Ridge National Laboratory (ORNL) to perform calculations for criticality safety, reactor physics, and radiation shielding applications. SCALE calculations typically use sequences that execute a predefined series of executable modules to compute particle fluxes and responses like the critical multiplication factor. SCALE also includes modules for sensitivity and uncertainty (S/U) analysis of calculated responses. The S/U codes in SCALE are collectively referred to as TSUNAMI (Tools for Sensitivity and UNcertainty Analysis Methodology Implementation). SCALE-6-scheduled for release in 2008-contains significant new capabilities, including important enhancements in S/U methods and data. The main functions of TSUNAMI are to (a) compute nuclear data sensitivity coefficients and response uncertainties, (b) establish similarity between benchmark experiments and design applications, and (c) reduce uncertainty in calculated responses by consolidating integral benchmark experiments. TSUNAMI includes easy-to-use graphical user interfaces for defining problem input and viewing three-dimensional (3D) geometries, as well as an integrated plotting package.

  11. Studies on analytical method and nondestructive measuring method on the sensitization of austenitic stainless steels

    International Nuclear Information System (INIS)

    Onimura, Kichiro; Arioka, Koji; Horai, Manabu; Noguchi, Shigeru.

    1982-03-01

    Austenitic stainless steels are widely used as structural materials for the machine and equipment of various kinds of plants, such as thermal power, nuclear power, and chemical plants. The machines and equipment using this kind of material, however, have the possibility of suffering corrosion damage while in service, and these damages are considered to be largely due to the sensitization of the material in sometimes. So, it is necessary to develop an analytical method for grasping the sensitization of the material more in detail and a quantitative nondestructive measuring method which is applicable to various kinds of structures in order to prevent the corrosion damage. From the above viewpoint, studies have been made on the analytical method based on the theory of diffusion of chromium in austenitic stainless steels and on Electro-Potentiokinetics Reactivation Method (EPR Method) as a nondestructive measuring method, using 304 and 316 austenitic stainless steels having different carbon contents in base metals. This paper introduces the results of EPR test on the sensitization of austenitic stainless steels and the correlation between analytical and experimental results. (author)

  12. Sensitivity analysis of the Two Geometry Method

    International Nuclear Information System (INIS)

    Wichers, V.A.

    1993-09-01

    The Two Geometry Method (TGM) was designed specifically for the verification of the uranium enrichment of low enriched UF 6 gas in the presence of uranium deposits on the pipe walls. Complications can arise if the TGM is applied under extreme conditions, such as deposits larger than several times the gas activity, small pipe diameters less than 40 mm and low pressures less than 150 Pa. This report presents a comprehensive sensitivity analysis of the TGM. The impact of the various sources of uncertainty on the performance of the method is discussed. The application to a practical case is based on worst case conditions with regards to the measurement conditions, and on realistic conditions with respect to the false alarm probability and the non detection probability. Monte Carlo calculations were used to evaluate the sensitivity for sources of uncertainty which are experimentally inaccessible. (orig.)

  13. Quantification of rapid Myosin regulatory light chain phosphorylation using high-throughput in-cell Western assays: comparison to Western immunoblots.

    Directory of Open Access Journals (Sweden)

    Hector N Aguilar

    2010-04-01

    Full Text Available Quantification of phospho-proteins (PPs is crucial when studying cellular signaling pathways. Western immunoblotting (WB is commonly used for the measurement of relative levels of signaling intermediates in experimental samples. However, WB is in general a labour-intensive and low-throughput technique. Because of variability in protein yield and phospho-signal preservation during protein harvesting, and potential loss of antigen during protein transfer, WB provides only semi-quantitative data. By comparison, the "in-cell western" (ICW technique has high-throughput capacity and requires less extensive sample preparation. Thus, we compared the ICW technique to WB for measuring phosphorylated myosin regulatory light chain (PMLC(20 in primary cultures of uterine myocytes to assess their relative specificity, sensitivity, precision, and quantification of biologically relevant responses.ICWs are cell-based microplate assays for quantification of protein targets in their cellular context. ICWs utilize a two-channel infrared (IR scanner (Odyssey(R to quantify signals arising from near-infrared (NIR fluorophores conjugated to secondary antibodies. One channel is dedicated to measuring the protein of interest and the second is used for data normalization of the signal in each well of the microplate. Using uterine myocytes, we assessed oxytocin (OT-stimulated MLC(20 phosphorylation measured by ICW and WB, both using NIR fluorescence. ICW and WB data were comparable regarding signal linearity, signal specificity, and time course of phosphorylation response to OT.ICW and WB yield comparable biological data. The advantages of ICW over WB are its high-throughput capacity, improved precision, and reduced sample preparation requirements. ICW might provide better sensitivity and precision with low-quantity samples or for protocols requiring large numbers of samples. These features make the ICW technique an excellent tool for the study of phosphorylation endpoints

  14. Comparative analysis of excretory-secretory antigens of Trichinella spiralis and Trichinella britovi muscle larvae by two-dimensional difference gel electrophoresis and immunoblotting.

    Science.gov (United States)

    Bien, Justyna; Näreaho, Anu; Varmanen, Pekka; Gozdzik, Katarzyna; Moskwa, Bozena; Cabaj, Wladyslaw; Nyman, Tuula A; Savijoki, Kirsi

    2012-02-11

    Trichinellosis is a zoonotic disease in humans caused by Trichinella spp. The present study was undertaken to discover excretory-secretory (E-S) proteins from T. spiralis and T. britovi muscle larvae (ML) that hold promise for species-specific diagnostics. To that end, the purified E-S proteins were analyzed by fluorescent two-dimensional difference gel electrophoresis (2-D DIGE) coupled with protein identification by liquid chromatography-tandem mass spectrometry (LC-MS/MS). To search for immunoreactive proteins that are specifically recognized by host antibodies the E-S proteins were subjected to two-dimensional (2-DE) immunoblotting with antisera derived from pigs experimentally infected with T. spiralis or T. britovi. According to 2-D DIGE analysis, a total of twenty-two proteins including potentially immunogenic proteins and proteins produced only by one of the two Trichinella species were subjected to LC-MS/MS for protein identification. From these proteins seventeen could be identified, of which many were identified in multiple spots, suggesting that they have undergone post-translational modification, possibly involving glycosylation and/or proteolysis. These proteins included 5'-nucleotidase, serine-type protease/proteinase, and p43 glycoprotein (gp43) as well as 49 kDa E-S protein (p49). Our findings also suggest that some of the commonly identified proteins were post-translationally modified to different extents, which in certain cases seemed to result in species-specific modification. Both commonly and specifically recognized immunoreactive proteins were identified by 2-DE immunoblotting; shared antigens were identified as gp43 and different protease variants, whereas those specific to T. britovi included multiple isoforms of the 5'-nucleotidase. Both 2-D DIGE and 2-DE immunoblotting approaches indicate that T. spiralis and T. britovi produce somewhat distinctive antigen profiles, which contain E-S antigens with potential as species-specific diagnostic

  15. Comparison of global sensitivity analysis methods – Application to fuel behavior modeling

    Energy Technology Data Exchange (ETDEWEB)

    Ikonen, Timo, E-mail: timo.ikonen@vtt.fi

    2016-02-15

    Highlights: • Several global sensitivity analysis methods are compared. • The methods’ applicability to nuclear fuel performance simulations is assessed. • The implications of large input uncertainties and complex models are discussed. • Alternative strategies to perform sensitivity analyses are proposed. - Abstract: Fuel performance codes have two characteristics that make their sensitivity analysis challenging: large uncertainties in input parameters and complex, non-linear and non-additive structure of the models. The complex structure of the code leads to interactions between inputs that show as cross terms in the sensitivity analysis. Due to the large uncertainties of the inputs these interactions are significant, sometimes even dominating the sensitivity analysis. For the same reason, standard linearization techniques do not usually perform well in the analysis of fuel performance codes. More sophisticated methods are typically needed in the analysis. To this end, we compare the performance of several sensitivity analysis methods in the analysis of a steady state FRAPCON simulation. The comparison of importance rankings obtained with the various methods shows that even the simplest methods can be sufficient for the analysis of fuel maximum temperature. However, the analysis of the gap conductance requires more powerful methods that take into account the interactions of the inputs. In some cases, moment-independent methods are needed. We also investigate the computational cost of the various methods and present recommendations as to which methods to use in the analysis.

  16. The expression and serological reactivity of recombinant canine herpesvirus 1 glycoprotein D

    Directory of Open Access Journals (Sweden)

    MarkéŽta Vaňkov‡á

    2016-01-01

    Full Text Available The aim of this work was to express recombinant glycoprotein D of canine herpesvirus 1 in bacterial cells and to evaluate its diagnostic sensitivity and specificity when compared to traditional serological methods. The gene fragment coding glycoprotein D of canine herpesvirus 1 was amplified by polymerase chain reaction, cloned into plasmid vector and expressed in Escherichia coli cells. Recombinant protein was then purified and used as an antigen in immunoblot for a detection of canine herpesvirus 1 specific antibodies. Antibody testing was performed on the panel of 100 canine sera by immunoblot with recombinant glycoprotein D as antigen and compared with indirect immunofluorescence assay. Serum samples were collected from 83 dogs with no history of canine herpesvirus 1 or reproductive disorders, and from 17 dogs from breeding kennels with a history of canine herpesvirus 1 related reproductive disorders. Sensitivity of glycoprotein D based immunoblot was 89.2% and specificity was 93%. Kappa value was calculated to be 0.8 between immunoblot and indirect immunofluorescence assay. Antibodies against canine herpesvirus 1 infection were detected in 33% of samples by immunoblot assay. Our study confirms that recombinant glycoprotein D expressed in bacterial cells could be used as a suitable and sensitive antigen for immunological tests and that herpesvirus infection seems to be common among the canine population in the Czech Republic.

  17. Design Optimization Method for Composite Components Based on Moment Reliability-Sensitivity Criteria

    Science.gov (United States)

    Sun, Zhigang; Wang, Changxi; Niu, Xuming; Song, Yingdong

    2017-08-01

    In this paper, a Reliability-Sensitivity Based Design Optimization (RSBDO) methodology for the design of the ceramic matrix composites (CMCs) components has been proposed. A practical and efficient method for reliability analysis and sensitivity analysis of complex components with arbitrary distribution parameters are investigated by using the perturbation method, the respond surface method, the Edgeworth series and the sensitivity analysis approach. The RSBDO methodology is then established by incorporating sensitivity calculation model into RBDO methodology. Finally, the proposed RSBDO methodology is applied to the design of the CMCs components. By comparing with Monte Carlo simulation, the numerical results demonstrate that the proposed methodology provides an accurate, convergent and computationally efficient method for reliability-analysis based finite element modeling engineering practice.

  18. A method of the sensitivity analysis of build-up and decay of actinides

    International Nuclear Information System (INIS)

    Mitani, Hiroshi; Koyama, Kinji; Kuroi, Hideo

    1977-07-01

    To make sensitivity analysis of build-up and decay of actinides, mathematical methods related to this problem have been investigated in detail. Application of time-dependent perturbation technique and Bateman method to sensitivity analysis is mainly studied. For the purpose, a basic equation and its adjoint equation for build-up and decay of actinides are systematically solved by introducing Laplace and modified Laplace transforms and their convolution theorems. Then, the mathematical method of sensitivity analyses is formulated by the above technique; its physical significance is also discussed. Finally, application of eigenvalue-method is investigated. Sensitivity coefficients can be directly calculated by this method. (auth.)

  19. Incorporation of β-actin loading control into zymography.

    Science.gov (United States)

    Govindasamy, Natasha; Yan, MengJie; Jurasz, Paul

    2016-11-01

    Gelatin zymography and immunoblot are widely used gel electrophoresis techniques to study matrix metalloproteinases-2 and -9. Each method has its advantages and disadvantages. Zymography is exquisitely sensitive but offers no loading control to ensure equal sample loading. Immunoblot is a 100-1000-fold less sensitive, but allows for the probing of a sample loading control such as β-actin to ensure accurate protein loading. In this report, we describe two simple protocols that combine gelatin zymography to study MMP-2 and -9 levels with an in-gel β-actin immunoblot loading control, thus combining sensitivity and accuracy in a single assay. The protocols incorporate the loading of molecular weight markers to demarcate MMP-2/-9 from the β-actin. The first protocol utilizes the overlay of a 10% zymography gel over a 5% Tris-Glycine separating gel from which the β-actin is transferred. The second protocol involves the direct transfer of the β-actin from a single 10% zymography gel.

  20. Sensitivity of radiation methods of diagnosis of electric potentials in dielectric materials

    International Nuclear Information System (INIS)

    Sapozhkov, Yu.I.; Smekalin, L.F.; Yagushkin, N.I.

    1985-01-01

    On the base of the albedo method the characteristics of radiation methods of diagnosis of electric potentials inside dielectrics, such as sensitivity and resolution are considered. Investigations are carried out for electron energies of tens keV. It is shown that with energy growth the sensitivity to electric field in the dielectrics volume drops. The target atomic number growth reduces the sensitivity approximately 1/lnz. The albedo method resolution in the investigated energy range is constant. The results obtained testify to the usability radiation methods of the diagnosis for control of electric fields of dielectric structural materials in the course of their operation

  1. Multiple predictor smoothing methods for sensitivity analysis: Description of techniques

    International Nuclear Information System (INIS)

    Storlie, Curtis B.; Helton, Jon C.

    2008-01-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described: (i) locally weighted regression (LOESS), (ii) additive models, (iii) projection pursuit regression, and (iv) recursive partitioning regression. Then, in the second and concluding part of this presentation, the indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present

  2. Deterministic methods for sensitivity and uncertainty analysis in large-scale computer models

    International Nuclear Information System (INIS)

    Worley, B.A.; Oblow, E.M.; Pin, F.G.; Maerker, R.E.; Horwedel, J.E.; Wright, R.Q.; Lucius, J.L.

    1987-01-01

    The fields of sensitivity and uncertainty analysis are dominated by statistical techniques when large-scale modeling codes are being analyzed. This paper reports on the development and availability of two systems, GRESS and ADGEN, that make use of computer calculus compilers to automate the implementation of deterministic sensitivity analysis capability into existing computer models. This automation removes the traditional limitation of deterministic sensitivity methods. The paper describes a deterministic uncertainty analysis method (DUA) that uses derivative information as a basis to propagate parameter probability distributions to obtain result probability distributions. The paper demonstrates the deterministic approach to sensitivity and uncertainty analysis as applied to a sample problem that models the flow of water through a borehole. The sample problem is used as a basis to compare the cumulative distribution function of the flow rate as calculated by the standard statistical methods and the DUA method. The DUA method gives a more accurate result based upon only two model executions compared to fifty executions in the statistical case

  3. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Zhang, Kai [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhu, Peiping; Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China and Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

  4. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili; Zhang, Kai; Zhu, Peiping; Wu, Ziyu

    2015-01-01

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations

  5. Comparison of diagnostic methods to detect Histoplasma capsulatum in serum and blood samples from AIDS patients

    Science.gov (United States)

    da Silva, Marcos Vinicius; Criado, Paulo Ricardo; Luiz, Olinda do Carmo; Vicentini, Adriana Pardini

    2018-01-01

    Background Although early and rapid detection of histoplasmosis is essential to prevent morbidity and mortality, few diagnostic tools are available in resource-limited areas, especially where it is endemic and HIV/AIDS is also epidemic. Thus, we compared conventional and molecular methods to detect Histoplasma capsulatum in sera and blood from HIV/AIDS patients. Methodology We collected a total of 40 samples from control volunteers and patients suspected of histoplasmosis, some of whom were also infected with other pathogens. Samples were then analyzed by mycological, serological, and molecular methods, and stratified as histoplasmostic with (group I) or without AIDS (group II), uninfected (group III), and infected with HIV and other pathogens only (group IV). All patients were receiving treatment for histoplasmosis and other infections at the time of sample collection. Results Comparison of conventional methods with nested PCR using primers against H. capsulatum 18S rRNA (HC18S), 5.8S rRNA ITS (HC5.8S-ITS), and a 100 kDa protein (HC100) revealed that sensitivity against sera was highest for PCR with HC5.8S-ITS, followed by immunoblotting, double immunodiffusion, PCR with HC18S, and PCR with HC100. Specificity was equally high for double immunodiffusion, immunoblotting and PCR with HC100, followed for PCR with HC18S and HC5.8-ITS. Against blood, sensitivity was highest for PCR with HC5.8S-ITS, followed by PCR with HC18S, Giemsa staining, and PCR with HC100. Specificity was highest for Giemsa staining and PCR with HC100, followed by PCR with HC18S and HC5.8S-ITS. PCR was less efficient in patients with immunodeficiency due to HIV/AIDS and/or related diseases. Conclusion Molecular techniques may detect histoplasmosis even in cases with negative serology and mycology, potentially enabling early diagnosis. PMID:29342162

  6. Comparison of diagnostic methods to detect Histoplasma capsulatum in serum and blood samples from AIDS patients.

    Directory of Open Access Journals (Sweden)

    Katia Cristina Dantas

    Full Text Available Although early and rapid detection of histoplasmosis is essential to prevent morbidity and mortality, few diagnostic tools are available in resource-limited areas, especially where it is endemic and HIV/AIDS is also epidemic. Thus, we compared conventional and molecular methods to detect Histoplasma capsulatum in sera and blood from HIV/AIDS patients.We collected a total of 40 samples from control volunteers and patients suspected of histoplasmosis, some of whom were also infected with other pathogens. Samples were then analyzed by mycological, serological, and molecular methods, and stratified as histoplasmostic with (group I or without AIDS (group II, uninfected (group III, and infected with HIV and other pathogens only (group IV. All patients were receiving treatment for histoplasmosis and other infections at the time of sample collection.Comparison of conventional methods with nested PCR using primers against H. capsulatum 18S rRNA (HC18S, 5.8S rRNA ITS (HC5.8S-ITS, and a 100 kDa protein (HC100 revealed that sensitivity against sera was highest for PCR with HC5.8S-ITS, followed by immunoblotting, double immunodiffusion, PCR with HC18S, and PCR with HC100. Specificity was equally high for double immunodiffusion, immunoblotting and PCR with HC100, followed for PCR with HC18S and HC5.8-ITS. Against blood, sensitivity was highest for PCR with HC5.8S-ITS, followed by PCR with HC18S, Giemsa staining, and PCR with HC100. Specificity was highest for Giemsa staining and PCR with HC100, followed by PCR with HC18S and HC5.8S-ITS. PCR was less efficient in patients with immunodeficiency due to HIV/AIDS and/or related diseases.Molecular techniques may detect histoplasmosis even in cases with negative serology and mycology, potentially enabling early diagnosis.

  7. An adjoint sensitivity-based data assimilation method and its comparison with existing variational methods

    Directory of Open Access Journals (Sweden)

    Yonghan Choi

    2014-01-01

    Full Text Available An adjoint sensitivity-based data assimilation (ASDA method is proposed and applied to a heavy rainfall case over the Korean Peninsula. The heavy rainfall case, which occurred on 26 July 2006, caused torrential rainfall over the central part of the Korean Peninsula. The mesoscale convective system (MCS related to the heavy rainfall was classified as training line/adjoining stratiform (TL/AS-type for the earlier period, and back building (BB-type for the later period. In the ASDA method, an adjoint model is run backwards with forecast-error gradient as input, and the adjoint sensitivity of the forecast error to the initial condition is scaled by an optimal scaling factor. The optimal scaling factor is determined by minimising the observational cost function of the four-dimensional variational (4D-Var method, and the scaled sensitivity is added to the original first guess. Finally, the observations at the analysis time are assimilated using a 3D-Var method with the improved first guess. The simulated rainfall distribution is shifted northeastward compared to the observations when no radar data are assimilated or when radar data are assimilated using the 3D-Var method. The rainfall forecasts are improved when radar data are assimilated using the 4D-Var or ASDA method. Simulated atmospheric fields such as horizontal winds, temperature, and water vapour mixing ratio are also improved via the 4D-Var or ASDA method. Due to the improvement in the analysis, subsequent forecasts appropriately simulate the observed features of the TL/AS- and BB-type MCSs and the corresponding heavy rainfall. The computational cost associated with the ASDA method is significantly lower than that of the 4D-Var method.

  8. On the Exploitation of Sensitivity Derivatives for Improving Sampling Methods

    Science.gov (United States)

    Cao, Yanzhao; Hussaini, M. Yousuff; Zang, Thomas A.

    2003-01-01

    Many application codes, such as finite-element structural analyses and computational fluid dynamics codes, are capable of producing many sensitivity derivatives at a small fraction of the cost of the underlying analysis. This paper describes a simple variance reduction method that exploits such inexpensive sensitivity derivatives to increase the accuracy of sampling methods. Three examples, including a finite-element structural analysis of an aircraft wing, are provided that illustrate an order of magnitude improvement in accuracy for both Monte Carlo and stratified sampling schemes.

  9. Demodulation method for tilted fiber Bragg grating refractometer with high sensitivity

    Science.gov (United States)

    Pham, Xuantung; Si, Jinhai; Chen, Tao; Wang, Ruize; Yan, Lihe; Cao, Houjun; Hou, Xun

    2018-05-01

    In this paper, we propose a demodulation method for refractive index (RI) sensing with tilted fiber Bragg gratings (TFBGs). It operates by monitoring the TFBG cladding mode resonance "cut-off wavelengths." The idea of a "cut-off wavelength" and its determination method are introduced. The RI sensitivities of TFBGs are significantly enhanced in certain RI ranges by using our demodulation method. The temperature-induced cross sensitivity is eliminated. We also demonstrate a parallel-double-angle TFBG (PDTFBG), in which two individual TFBGs are inscribed in the fiber core in parallel using a femtosecond laser and a phase mask. The RI sensing range of the PDTFBG is significantly broader than that of a conventional single-angle TFBG. In addition, its RI sensitivity can reach 1023.1 nm/refractive index unit in the 1.4401-1.4570 RI range when our proposed demodulation method is used.

  10. Simultaneous identification of Trypanosoma cruzi surface and internal antigens reactive to different immunoglobulin classes (radio-immunoblotting Identificação simultânea de antígenos internos e de superfície de Trypanosoma cruzi reativos para diferentes classes de imunoglobulinas (radio-immunoblotting

    Directory of Open Access Journals (Sweden)

    Anna Maria Simonsen Stolf

    1990-10-01

    Full Text Available A radioactive Western-blotting technique was developed by which the reactivity of Immunoglobulins (Igs from different classes to both membrane radiolabelled and internal parasite antigens is simultaneously identified. The method includes radioiodination of parasites, polypeptide fractionation by SDS-PAGE, Western-blot transfer and autoradiography of the immunoblots developed with anti-Igs conjugates labelled with enzymes. The analysis is then performed by the comparison of common bands on the autoradiograms and the respective substrate stained nitrocellulose blots. This technique was used to analyse T. cruzi trypomastigote surface labelled antigens reactive to IgM, IgA and IgG specific antibodies. A different pattern of reactivity with acute Chagas' disease patients sera was thus obtained.Classes e subclasses de anticorpos apresentam diferentes funções, influenciando a resposta imune humoral de um hospedeiro, frente a um agente infeccioso. Na maioria dos sistemas, o alvo principal é representado pelos antígenos de membrana do parasita. Entretanto, a identificação de antígenos de superfície de parasitas, reativos para classe (e subclasse de imunoglobulinas que não se ligam a proteína-A implica em imunoprecipitações sucessivas, que levam a perda de antígenos e/ou reações inespecíficas. Visando esse estudo, foi desenvolvida uma técnica denominada "radio-immunoblotting", através da qual a reatividade de imunoglobulinas de diferentes classes para antígenos de membrana (e/ou internos foi analisada simultaneamente. O método constitui na marcação prévia da superfície dos parasitas por radioiodação, fracionamento dos polipeptídeos por SDS/PA-GE, transferência das frações para nitrocelulose, reação com soros e conjugados anti-Igs - peroxidase e autoradiografia dos mesmos, a análise é feita comparando-se os antígenos comuns evidenciados na autoradiografia e nas tiras de nitrocelulose coradas com o substrato da peroxidase

  11. High sensitive quench detection method using an integrated test wire

    International Nuclear Information System (INIS)

    Fevrier, A.; Tavergnier, J.P.; Nithart, H.; Kiblaire, M.; Duchateau, J.L.

    1981-01-01

    A high sensitive quench detection method which works even in the presence of an external perturbing magnetic field is reported. The quench signal is obtained from the difference in voltages at the superconducting winding terminals and at the terminals at a secondary winding strongly coupled to the primary. The secondary winding could consist of a ''zero-current strand'' of the superconducting cable not connected to one of the winding terminals or an integrated normal test wire inside the superconducting cable. Experimental results on quench detection obtained by this method are described. It is shown that the integrated test wire method leads to efficient and sensitive quench detection, especially in the presence of an external perturbing magnetic field

  12. The adjoint sensitivity method, a contribution to the code uncertainty evaluation

    International Nuclear Information System (INIS)

    Ounsy, A.; Crecy, F. de; Brun, B.

    1993-01-01

    The application of the ASM (Adjoint Sensitivity Method) to thermohydraulic codes, is examined. The advantage of the method is to be very few CPU time consuming in comparison with usual approach requiring one complete code run per sensitivity determination. The mathematical aspects of the problem are first described, and the applicability of the method of the functional-type response of a thermalhydraulic model is demonstrated. On a simple example of non linear hyperbolic equation (Burgers equation) the problem has been analyzed. It is shown that the formalism used in the literature treating this subject is not appropriate. A new mathematical formalism circumventing the problem is proposed. For the discretized form of the problem, two methods are possible: the Continuous ASM and the Discrete ASM. The equivalence of both methods is demonstrated; nevertheless only the DASM constitutes a practical solution for thermalhydraulic codes. The application of the DASM to the thermalhydraulic safety code CATHARE is then presented for two examples. They demonstrate that ASM constitutes an efficient tool for the analysis of code sensitivity. (authors) 7 figs., 5 tabs., 8 refs

  13. The adjoint sensitivity method. A contribution to the code uncertainty evaluation

    International Nuclear Information System (INIS)

    Ounsy, A.; Brun, B.

    1993-01-01

    The application of the ASM (Adjoint Sensitivity Method) to thermohydraulic codes, is examined. The advantage of the method is to be very few CPU time consuming in comparison with usual approach requiring one complete code run per sensitivity determination. The mathematical aspects of the problem are first described, and the applicability of the method of the functional-type response of a thermalhydraulic model is demonstrated. On a simple example of non linear hyperbolic equation (Burgers equation) the problem has been analyzed. It is shown that the formalism used in the literature treating this subject is not appropriate. A new mathematical formalism circumventing the problem is proposed. For the discretized form of the problem, two methods are possible: the Continuous ASM and the Discrete ASM. The equivalence of both methods is demonstrated; nevertheless only the DASM constitutes a practical solution for thermalhydraulic codes. The application of the DASM to the thermalhydraulic safety code CATHARE is then presented for two examples. They demonstrate that ASM constitutes an efficient tool for the analysis of code sensitivity. (authors) 7 figs., 5 tabs., 8 refs

  14. The adjoint sensitivity method. A contribution to the code uncertainty evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ounsy, A; Brun, B

    1994-12-31

    The application of the ASM (Adjoint Sensitivity Method) to thermohydraulic codes, is examined. The advantage of the method is to be very few CPU time consuming in comparison with usual approach requiring one complete code run per sensitivity determination. The mathematical aspects of the problem are first described, and the applicability of the method of the functional-type response of a thermalhydraulic model is demonstrated. On a simple example of non linear hyperbolic equation (Burgers equation) the problem has been analyzed. It is shown that the formalism used in the literature treating this subject is not appropriate. A new mathematical formalism circumventing the problem is proposed. For the discretized form of the problem, two methods are possible: the Continuous ASM and the Discrete ASM. The equivalence of both methods is demonstrated; nevertheless only the DASM constitutes a practical solution for thermalhydraulic codes. The application of the DASM to the thermalhydraulic safety code CATHARE is then presented for two examples. They demonstrate that ASM constitutes an efficient tool for the analysis of code sensitivity. (authors) 7 figs., 5 tabs., 8 refs.

  15. The adjoint sensitivity method, a contribution to the code uncertainty evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ounsy, A; Crecy, F de; Brun, B

    1994-12-31

    The application of the ASM (Adjoint Sensitivity Method) to thermohydraulic codes, is examined. The advantage of the method is to be very few CPU time consuming in comparison with usual approach requiring one complete code run per sensitivity determination. The mathematical aspects of the problem are first described, and the applicability of the method of the functional-type response of a thermalhydraulic model is demonstrated. On a simple example of non linear hyperbolic equation (Burgers equation) the problem has been analyzed. It is shown that the formalism used in the literature treating this subject is not appropriate. A new mathematical formalism circumventing the problem is proposed. For the discretized form of the problem, two methods are possible: the Continuous ASM and the Discrete ASM. The equivalence of both methods is demonstrated; nevertheless only the DASM constitutes a practical solution for thermalhydraulic codes. The application of the DASM to the thermalhydraulic safety code CATHARE is then presented for two examples. They demonstrate that ASM constitutes an efficient tool for the analysis of code sensitivity. (authors) 7 figs., 5 tabs., 8 refs.

  16. Adjoint sensitivity analysis of plasmonic structures using the FDTD method.

    Science.gov (United States)

    Zhang, Yu; Ahmed, Osman S; Bakr, Mohamed H

    2014-05-15

    We present an adjoint variable method for estimating the sensitivities of arbitrary responses with respect to the parameters of dispersive discontinuities in nanoplasmonic devices. Our theory is formulated in terms of the electric field components at the vicinity of perturbed discontinuities. The adjoint sensitivities are computed using at most one extra finite-difference time-domain (FDTD) simulation regardless of the number of parameters. Our approach is illustrated through the sensitivity analysis of an add-drop coupler consisting of a square ring resonator between two parallel waveguides. The computed adjoint sensitivities of the scattering parameters are compared with those obtained using the accurate but computationally expensive central finite difference approach.

  17. Statistical Sensitive Data Protection and Inference Prevention with Decision Tree Methods

    National Research Council Canada - National Science Library

    Chang, LiWu

    2003-01-01

    .... We consider inference as correct classification and approach it with decision tree methods. As in our previous work, sensitive data are viewed as classes of those test data and non-sensitive data are the rest attribute values...

  18. Prediction of skin sensitizers using alternative methods to animal experimentation.

    Science.gov (United States)

    Johansson, Henrik; Lindstedt, Malin

    2014-07-01

    Regulatory frameworks within the European Union demand that chemical substances are investigated for their ability to induce sensitization, an adverse health effect caused by the human immune system in response to chemical exposure. A recent ban on the use of animal tests within the cosmetics industry has led to an urgent need for alternative animal-free test methods that can be used for assessment of chemical sensitizers. To date, no such alternative assay has yet completed formal validation. However, a number of assays are in development and the understanding of the biological mechanisms of chemical sensitization has greatly increased during the last decade. In this MiniReview, we aim to summarize and give our view on the recent progress of method development for alternative assessment of chemical sensitizers. We propose that integrated testing strategies should comprise complementary assays, providing measurements of a wide range of mechanistic events, to perform well-educated risk assessments based on weight of evidence. © 2014 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  19. Application of Wielandt method in continuous-energy nuclear data sensitivity analysis with RMC code

    International Nuclear Information System (INIS)

    Qiu Yishu; Wang Kan; She Ding

    2015-01-01

    The Iterated Fission Probability (IFP) method, an accurate method to estimate adjoint-weighted quantities in the continuous-energy Monte Carlo criticality calculations, has been widely used for calculating kinetic parameters and nuclear data sensitivity coefficients. By using a strategy of waiting, however, this method faces the challenge of high memory usage to store the tallies of original contributions which size is proportional to the number of particle histories in each cycle. Recently, the Wielandt method, applied by Monte Carlo code McCARD to calculate kinetic parameters, estimates adjoint fluxes in a single particle history and thus can save memory usage. In this work, the Wielandt method has been applied in Rector Monte Carlo code RMC for nuclear data sensitivity analysis. The methodology and algorithm of applying Wielandt method in estimation of adjoint-based sensitivity coefficients are discussed. Verification is performed by comparing the sensitivity coefficients calculated by Wielandt method with analytical solutions, those computed by IFP method which is also implemented in RMC code for sensitivity analysis, and those from the multi-group TSUNAMI-3D module in SCALE code package. (author)

  20. Sensitive high performance liquid chromatographic method for the ...

    African Journals Online (AJOL)

    A new simple, sensitive, cost-effective and reproducible high performance liquid chromatographic (HPLC) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 4-chlorophenylbiguanide (4-CPB) in urine and plasma is described. The extraction procedure is a simple three-step process ...

  1. Space-partition method for the variance-based sensitivity analysis: Optimal partition scheme and comparative study

    International Nuclear Information System (INIS)

    Zhai, Qingqing; Yang, Jun; Zhao, Yu

    2014-01-01

    Variance-based sensitivity analysis has been widely studied and asserted itself among practitioners. Monte Carlo simulation methods are well developed in the calculation of variance-based sensitivity indices but they do not make full use of each model run. Recently, several works mentioned a scatter-plot partitioning method to estimate the variance-based sensitivity indices from given data, where a single bunch of samples is sufficient to estimate all the sensitivity indices. This paper focuses on the space-partition method in the estimation of variance-based sensitivity indices, and its convergence and other performances are investigated. Since the method heavily depends on the partition scheme, the influence of the partition scheme is discussed and the optimal partition scheme is proposed based on the minimized estimator's variance. A decomposition and integration procedure is proposed to improve the estimation quality for higher order sensitivity indices. The proposed space-partition method is compared with the more traditional method and test cases show that it outperforms the traditional one

  2. The adjoint sensitivity method, a contribution to the code uncertainty evaluation

    International Nuclear Information System (INIS)

    Ounsy, A.; Brun, B.; De Crecy, F.

    1994-01-01

    This paper deals with the application of the adjoint sensitivity method (ASM) to thermal hydraulic codes. The advantage of the method is to use small central processing unit time in comparison with the usual approach requiring one complete code run per sensitivity determination. In the first part the mathematical aspects of the problem are treated, and the applicability of the method of the functional-type response of a thermal hydraulic model is demonstrated. On a simple example of non-linear hyperbolic equation (Burgers equation) the problem has been analysed. It is shown that the formalism used in the literature treating this subject is not appropriate. A new mathematical formalism circumventing the problem is proposed. For the discretized form of the problem, two methods are possible: the continuous ASM and the discrete ASM. The equivalence of both methods is demonstrated; nevertheless only the discrete ASM constitutes a practical solution for thermal hydraulic codes. The application of the discrete ASM to the thermal hydraulic safety code CATHARE is then presented for two examples. They demonstrate that the discrete ASM constitutes an efficient tool for the analysis of code sensitivity. ((orig.))

  3. Application of Monte Carlo filtering method in regional sensitivity analysis of AASHTOWare Pavement ME design

    Directory of Open Access Journals (Sweden)

    Zhong Wu

    2017-04-01

    Full Text Available Since AASHTO released the Mechanistic-Empirical Pavement Design Guide (MEPDG for public review in 2004, many highway research agencies have performed sensitivity analyses using the prototype MEPDG design software. The information provided by the sensitivity analysis is essential for design engineers to better understand the MEPDG design models and to identify important input parameters for pavement design. In literature, different studies have been carried out based on either local or global sensitivity analysis methods, and sensitivity indices have been proposed for ranking the importance of the input parameters. In this paper, a regional sensitivity analysis method, Monte Carlo filtering (MCF, is presented. The MCF method maintains many advantages of the global sensitivity analysis, while focusing on the regional sensitivity of the MEPDG model near the design criteria rather than the entire problem domain. It is shown that the information obtained from the MCF method is more helpful and accurate in guiding design engineers in pavement design practices. To demonstrate the proposed regional sensitivity method, a typical three-layer flexible pavement structure was analyzed at input level 3. A detailed procedure to generate Monte Carlo runs using the AASHTOWare Pavement ME Design software was provided. The results in the example show that the sensitivity ranking of the input parameters in this study reasonably matches with that in a previous study under a global sensitivity analysis. Based on the analysis results, the strengths, practical issues, and applications of the MCF method were further discussed.

  4. Sensitivity analysis of a complex, proposed geologic waste disposal system using the Fourier Amplitude Sensitivity Test method

    International Nuclear Information System (INIS)

    Lu Yichi; Mohanty, Sitakanta

    2001-01-01

    The Fourier Amplitude Sensitivity Test (FAST) method has been used to perform a sensitivity analysis of a computer model developed for conducting total system performance assessment of the proposed high-level nuclear waste repository at Yucca Mountain, Nevada, USA. The computer model has a large number of random input parameters with assigned probability density functions, which may or may not be uniform, for representing data uncertainty. The FAST method, which was previously applied to models with parameters represented by the uniform probability distribution function only, has been modified to be applied to models with nonuniform probability distribution functions. Using an example problem with a small input parameter set, several aspects of the FAST method, such as the effects of integer frequency sets and random phase shifts in the functional transformations, and the number of discrete sampling points (equivalent to the number of model executions) on the ranking of the input parameters have been investigated. Because the number of input parameters of the computer model under investigation is too large to be handled by the FAST method, less important input parameters were first screened out using the Morris method. The FAST method was then used to rank the remaining parameters. The validity of the parameter ranking by the FAST method was verified using the conditional complementary cumulative distribution function (CCDF) of the output. The CCDF results revealed that the introduction of random phase shifts into the functional transformations, proposed by previous investigators to disrupt the repetitiveness of search curves, does not necessarily improve the sensitivity analysis results because it destroys the orthogonality of the trigonometric functions, which is required for Fourier analysis

  5. Further development of LLNA:DAE method as stand-alone skin-sensitization testing method and applied for evaluation of relative skin-sensitizing potency between chemicals.

    Science.gov (United States)

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi

    2015-04-01

    To date, there has been no well-established local lymph node assay (LLNA) that includes an elicitation phase. Therefore, we developed a modified local lymph node assay with an elicitation phase (LLNA:DAE) to discriminate true skin sensitizers from chemicals that gave borderline positive results and previously reported this assay. To develop the LLNA:DAE method as a useful stand-alone testing method, we investigated the complete procedure for the LLNA:DAE method using hexyl cinnamic aldehyde (HCA), isoeugenol, and 2,4-dinitrochlorobenzene (DNCB) as test compounds. We defined the LLNA:DAE procedure as follows: in the dose-finding test, four concentrations of chemical applied to dorsum of the right ear on days 1, 2, and 3 and dorsum of both ears on day 10. Ear thickness and skin irritation score were measured on days 1, 3, 5, 10, and 12. Local lymph nodes were excised and weighed on day 12. The test dose for the primary LLNA:DAE study was selected as the dose that gave the highest left ear lymph node weight in the dose-finding study, or the lowest dose that produced a left ear lymph node of over 4 mg. This procedure was validated using nine different chemicals. Furthermore, qualitative relationship was observed between the degree of elicitation response in the left ear lymph node and the skin sensitizing potency of 32 chemicals tested in this study and the previous study. These results indicated that LLNA:DAE method was as first LLNA method that was able to evaluate the skin sensitizing potential and potency in elicitation response.

  6. A Sensitive Validated Spectrophotometric Method for the Determination of Flucloxacillin Sodium

    Directory of Open Access Journals (Sweden)

    R. Singh Gujral

    2009-01-01

    Full Text Available A simple and sensitive spectrophotometric method has been proposed for the determination of flucloxacillin sodium. The determination method is based on charge transfer complexation reaction of the drug with iodine in methanol-dichloromethane medium. The absorbance was measured at 362 nm against the reagent blank. Under optimized experimental conditions, Beer's law is obeyed in the concentration ranges 1-9 μg/mL for flucloxacillin. The method was validated for specificity, linearity, precision, accuracy. The degree of linearity of the calibration curves, the percent recoveries, limit of detection and quantitation for the spectrophotometric method were determined. No interferences could be observed from the additives commonly present in the pharmaceutical formulations. The method was successfully applied for in vitro determination of human urine samples with low RSD value. This is simple, specific, accurate and sensitive spectrophotometric method.

  7. A combination between the differential and the perturbation theory methods for calculating sensitivity coefficients

    International Nuclear Information System (INIS)

    Borges, Antonio Andrade

    1998-01-01

    A new method for the calculation of sensitivity coefficients is developed. The new method is a combination of two methodologies used for calculating theses coefficients, which are the differential and the generalized perturbation theory methods. The method utilizes as integral parameter the average flux in an arbitrary region of the system. Thus, the sensitivity coefficient contains only the component corresponding to the neutron flux. To obtain the new sensitivity coefficient, the derivatives of the integral parameter, Φ, with respect to σ are calculated using the perturbation method and the functional derivatives of this generic integral parameter with respect to σ and Φ are calculated using the differential method. (author)

  8. Partial purification and characterization of a wortmannin-sensitive and insulin-stimulated protein kinase that activates heart 6-phosphofructo-2-kinase.

    OpenAIRE

    Deprez, J; Bertrand, L; Alessi, D R; Krause, U; Hue, L; Rider, M H

    2000-01-01

    A wortmannin-sensitive and insulin-stimulated protein kinase (WISK), which phosphorylates and activates cardiac 6-phosphofructo-2-kinase (PFK-2), was partially purified from perfused rat hearts. Immunoblotting showed that WISK was devoid of protein kinase B (PKB), serum- and glucocorticoid-regulated protein kinase and protein kinase Czeta (PKCzeta). Comparison of the inhibition of WISK, PKCalpha and PKCzeta by different protein kinase inhibitors suggested that WISK was not a member of the PKC...

  9. Method and apparatus for formation logging using position sensitive neutron detectors

    International Nuclear Information System (INIS)

    Gadken, L.L.

    1986-01-01

    This patent describes a method for logging earth formations using position sensitive neutron detectors. The method consists of: 1) Irradiation of earth formations in the vicinity of a well borehole with a source of fast neutrons. 2) At four longitudinally spaced distances from the neutron source in the borehole, the epithermal neutron population is detected. Each of the four separate populations is detected in an epithermally sensitive and substantially thermally insensitive portion of the same position sensitive neutron detector. A representative signal from each is then individually generated. 3) First, second, third, and fourth neutron population representative signals are combined. They derive a simultaneous measurement signal. This signal is functionally related to the porosity and also a signal functionally related to a neutron characteristic length of the earth formations in the vicinity of the borehole

  10. A combination of differential method and perturbation theory for the calculation of sensitivity coefficients

    International Nuclear Information System (INIS)

    Santos, Adimir dos; Borges, A.A.

    2000-01-01

    A new method for the calculation of sensitivity coefficients is developed. The new method is a combination of two methodologies used for calculating these coefficients, which are the differential and the generalized perturbation theory methods. The proposed method utilizes as integral parameter the average flux in an arbitrary region of the system. Thus, the sensitivity coefficient contains only the component corresponding to the neutron flux. To obtain the new sensitivity coefficient, the derivates of the integral parameter, φ(ξ), with respect to σ are calculated using the perturbation method and the functional derivates of this generic integral parameter with respect to σ and φ are calculated using the differential method. The new method merges the advantages of the differential and generalized perturbation theory methods and eliminates their disadvantages. (author)

  11. Sensitivity Analysis of Dynamic Tariff Method for Congestion Management in Distribution Networks

    DEFF Research Database (Denmark)

    Huang, Shaojun; Wu, Qiuwei; Liu, Zhaoxi

    2015-01-01

    The dynamic tariff (DT) method is designed for the distribution system operator (DSO) to alleviate the congestions that might occur in a distribution network with high penetration of distribute energy resources (DERs). Sensitivity analysis of the DT method is crucial because of its decentralized...... control manner. The sensitivity analysis can obtain the changes of the optimal energy planning and thereby the line loading profiles over the infinitely small changes of parameters by differentiating the KKT conditions of the convex quadratic programming, over which the DT method is formed. Three case...

  12. Sensitivity analysis for decision-making using the MORE method-A Pareto approach

    International Nuclear Information System (INIS)

    Ravalico, Jakin K.; Maier, Holger R.; Dandy, Graeme C.

    2009-01-01

    Integrated Assessment Modelling (IAM) incorporates knowledge from different disciplines to provide an overarching assessment of the impact of different management decisions. The complex nature of these models, which often include non-linearities and feedback loops, requires special attention for sensitivity analysis. This is especially true when the models are used to form the basis of management decisions, where it is important to assess how sensitive the decisions being made are to changes in model parameters. This research proposes an extension to the Management Option Rank Equivalence (MORE) method of sensitivity analysis; a new method of sensitivity analysis developed specifically for use in IAM and decision-making. The extension proposes using a multi-objective Pareto optimal search to locate minimum combined parameter changes that result in a change in the preferred management option. It is demonstrated through a case study of the Namoi River, where results show that the extension to MORE is able to provide sensitivity information for individual parameters that takes into account simultaneous variations in all parameters. Furthermore, the increased sensitivities to individual parameters that are discovered when joint parameter variation is taken into account shows the importance of ensuring that any sensitivity analysis accounts for these changes.

  13. An efficient method of reducing glass dispersion tolerance sensitivity

    Science.gov (United States)

    Sparrold, Scott W.; Shepard, R. Hamilton

    2014-12-01

    Constraining the Seidel aberrations of optical surfaces is a common technique for relaxing tolerance sensitivities in the optimization process. We offer an observation that a lens's Abbe number tolerance is directly related to the magnitude by which its longitudinal and transverse color are permitted to vary in production. Based on this observation, we propose a computationally efficient and easy-to-use merit function constraint for relaxing dispersion tolerance sensitivity. Using the relationship between an element's chromatic aberration and dispersion sensitivity, we derive a fundamental limit for lens scale and power that is capable of achieving high production yield for a given performance specification, which provides insight on the point at which lens splitting or melt fitting becomes necessary. The theory is validated by comparing its predictions to a formal tolerance analysis of a Cooke Triplet, and then applied to the design of a 1.5x visible linescan lens to illustrate optimization for reduced dispersion sensitivity. A selection of lenses in high volume production is then used to corroborate the proposed method of dispersion tolerance allocation.

  14. Aspectos epidemiológicos da dirofilariose canina no perímetro urbano de Cuiabá, Mato Grosso: emprego do "Immunoblot" e do teste de Knott modificado

    Directory of Open Access Journals (Sweden)

    Cláudia Gorgulho Nogueira Fernandes

    2000-12-01

    Full Text Available O presente trabalho refere-se a pesquisa dos aspectos epidemiológicos da dirofilariose canina no perímetro urbano de Cuiabá, através de exame de sangue e sorologia. Examinou-se o sangue de 822 cães: em 11,81% das amostras, detectaram-se, por meio de "Immunoblot", anticorpos contra antígenos de Dirofilaria immitis adulto, enquanto em 0,41% foram encontradas, por meio do teste de Knott modificado, microfilárias de D. immitis. A prevalência da dirofilariose canina em Cuiabá, no período de junho a novembro de 1997, e com a metodologia aplicada, foi de 120,8 casos em cada 1.000 animais. O "Immunoblot" diagnosticou como positivas 11,27% das amostras que estavam consideradas negativas pelo teste de Knott modificado. Os autores analisaram estatisticamente informações sobre raça, sexo, idade e região administrativa de origem dos cães pesquisados. Foi questionada a possibilidade de que os animais pesquisados tivessem viajado a regiões endêmicas, usado microfilaricidas, ou apresentado sintomatologia compatível, bem como estudadas as características ecológicas do local de moradia. Cães com idade variando entre um e nove anos e residentes na região Centro-Oeste apresentaram maior índice de positividade. A maioria não apresentava sintomatologia compatível com a doença, não tinha história clínica do uso de microfilaricidas e/ou preventivos contra dirofilariose canina e nunca havia saído do perímetro urbano de Cuiabá, mas residiam em bairros próximos a rios ou córregos e/ou em casas contíguas a áreas de vegetação nativa. Pela primeira vez, o "Immunoblot" foi empregado no diagnóstico de dirofilariose canina no Brasil.

  15. A highly sensitive method for detection of molybdenum-containing proteins

    International Nuclear Information System (INIS)

    Kalakutskii, K.L.; Shvetsov, A.A.; Bursakov, S.A.; Letarov, A.V.; Zabolotnyi, A.I.; L'vov, N.P.

    1992-01-01

    A highly sensitive method for detection of molybdenum-containing proteins in gels after electrophoresis has been developed. The method involves in vitro labeling of the proteins with the radioactive isotope 185 W. The method used to detect molybdenum-accumulating proteins in lupine seeds, xanthine dehydrogenase and another molybdenum-containing protein in wheat, barley, and pea seedlings, and nitrate reductase and xanthine dehydrogenase in bacteroides from lupine nodules. Nitrogenase could not be detected by the method. 16 refs., 5 figs

  16. A simple method to estimate the episode and programme sensitivity of breast cancer screening programmes.

    Science.gov (United States)

    Zorzi, Manuel; Guzzinati, Stefano; Puliti, Donella; Paci, Eugenio

    2010-01-01

    The estimation of breast cancer screening sensitivity is a major aim in the quality assessment of screening programmes. The proportional incidence method for the estimation of the sensitivity of breast cancer screening programmes is rarely used to estimate the underlying incidence rates. We present a method to estimate episode and programme sensitivity of screening programmes, based solely on cancers detected within screening cycles (excluding breast cancer cases at prevalent screening round) and on the number of incident cases in the total target population (steady state). The assumptions, strengths and limitations of the method are discussed. An example of calculation of episode and programme sensitivities is given, on the basis of the data from the IMPACT study, a large observational study of breast cancer screening programmes in Italy. The programme sensitivity from the fifth year of screening onwards ranged between 41% and 48% of the total number of cases in the target population. At steady state episode sensitivity was 0.70, with a trend across age groups, with lowest values in women aged 50-54 years (0.52) and highest in those 65-69 (0.77). The method is a very serviceable tool for estimating sensitivity in service screening programmes, and the results are comparable with those of other methods of estimation.

  17. Sensitivity evaluation of dynamic speckle activity measurements using clustering methods

    International Nuclear Information System (INIS)

    Etchepareborda, Pablo; Federico, Alejandro; Kaufmann, Guillermo H.

    2010-01-01

    We evaluate and compare the use of competitive neural networks, self-organizing maps, the expectation-maximization algorithm, K-means, and fuzzy C-means techniques as partitional clustering methods, when the sensitivity of the activity measurement of dynamic speckle images needs to be improved. The temporal history of the acquired intensity generated by each pixel is analyzed in a wavelet decomposition framework, and it is shown that the mean energy of its corresponding wavelet coefficients provides a suited feature space for clustering purposes. The sensitivity obtained by using the evaluated clustering techniques is also compared with the well-known methods of Konishi-Fujii, weighted generalized differences, and wavelet entropy. The performance of the partitional clustering approach is evaluated using simulated dynamic speckle patterns and also experimental data.

  18. Drop weight impact measurements of HE sensitivity: modified detection methods

    International Nuclear Information System (INIS)

    Preston, D N; Brown, G W; Tappan, B C; Oshwald, D M; Koby, J R; Schoonover, M L

    2014-01-01

    High explosives small-scale sensitivity testing has been a hallmark of safety screening since WWII. Sensitivity testing was once crude and simple; broom sticks were used to scrape explosives on the floor while experimenters would look, listen, and smell for signs of a reaction. Since then, a wide variety of testing apparatus have been developed to explore the effects of different stimuli on explosives. In concert with the development of the machines themselves, the reaction detection methods have also evolved. This paper's focus is on the Los Alamos National Laboratory's (LANL) drop weight impact machine and reaction detection methods. A critical evaluation of results is presented with cautionary examples of false positives that can occur with non-explosive materials.

  19. An easily implemented static condensation method for structural sensitivity analysis

    Science.gov (United States)

    Gangadharan, S. N.; Haftka, R. T.; Nikolaidis, E.

    1990-01-01

    A black-box approach to static condensation for sensitivity analysis is presented with illustrative examples of a cube and a car structure. The sensitivity of the structural response with respect to joint stiffness parameter is calculated using the direct method, forward-difference, and central-difference schemes. The efficiency of the various methods for identifying joint stiffness parameters from measured static deflections of these structures is compared. The results indicate that the use of static condensation can reduce computation times significantly and the black-box approach is only slightly less efficient than the standard implementation of static condensation. The ease of implementation of the black-box approach recommends it for use with general-purpose finite element codes that do not have a built-in facility for static condensation.

  20. Parvalbumin, a cross-reactive fish allergen, contains IgE-binding epitopes sensitive to periodate treatment and Ca2+ depletion.

    Science.gov (United States)

    Bugajska-Schretter, A; Elfman, L; Fuchs, T; Kapiotis, S; Rumpold, H; Valenta, R; Spitzauer, S

    1998-01-01

    Type I allergy to fish is a severe health problem in countries in which a large percentage of the population derive income from fishing. The aim of the study was to characterize cross-reactive IgE-binding components in six different fish species (cod, tuna, salmon, perch, carp, and eel). The effect of reducing extraction conditions, periodate treatment, and depletion of Ca2+ on binding of IgE to the allergens was investigated. Extracts were prepared under nonreducing and reducing conditions. IgE-binding components were characterized by IgE immunoblotting, and cross-reactive epitopes were studied by IgE-immunoblot inhibition experiments. To reveal calcium-sensitive or carbohydrate-containing epitopes, nitrocellulose-blotted extracts were exposed to ethylene glycol bis(beta-aminoethyl ether)-N,N,N',N'-tetraacetic acid (EGTA) and periodate. Sera from all patients allergic to fish (n = 30) displayed IgE reactivity to parvalbumin, a 12 kd protein present in fish extracts from six different species. Reducing extraction conditions had no effect on IgE binding to parvalbumins, whereas periodate treatment and depletion of protein-bound calcium led to a substantial reduction of IgE binding. Parvalbumins from six different species contained cross-reactive IgE epitopes. Parvalbumin represents a cross-reactive fish allergen. It contains IgE epitopes that are sensitive to periodate treatment and Ca2+-depletion.

  1. Development of a localized probabilistic sensitivity method to determine random variable regional importance

    International Nuclear Information System (INIS)

    Millwater, Harry; Singh, Gulshan; Cortina, Miguel

    2012-01-01

    There are many methods to identify the important variable out of a set of random variables, i.e., “inter-variable” importance; however, to date there are no comparable methods to identify the “region” of importance within a random variable, i.e., “intra-variable” importance. Knowledge of the critical region of an input random variable (tail, near-tail, and central region) can provide valuable information towards characterizing, understanding, and improving a model through additional modeling or testing. As a result, an intra-variable probabilistic sensitivity method was developed and demonstrated for independent random variables that computes the partial derivative of a probabilistic response with respect to a localized perturbation in the CDF values of each random variable. These sensitivities are then normalized in absolute value with respect to the largest sensitivity within a distribution to indicate the region of importance. The methodology is implemented using the Score Function kernel-based method such that existing samples can be used to compute sensitivities for negligible cost. Numerical examples demonstrate the accuracy of the method through comparisons with finite difference and numerical integration quadrature estimates. - Highlights: ► Probabilistic sensitivity methodology. ► Determines the “region” of importance within random variables such as left tail, near tail, center, right tail, etc. ► Uses the Score Function approach to reuse the samples, hence, negligible cost. ► No restrictions on the random variable types or limit states.

  2. Radiation sensitive devices and systems for detection of radioactive materials and related methods

    Science.gov (United States)

    Kotter, Dale K

    2014-12-02

    Radiation sensitive devices include a substrate comprising a radiation sensitive material and a plurality of resonance elements coupled to the substrate. Each resonance element is configured to resonate responsive to non-ionizing incident radiation. Systems for detecting radiation from a special nuclear material include a radiation sensitive device and a sensor located remotely from the radiation sensitive device and configured to measure an output signal from the radiation sensitive device. In such systems, the radiation sensitive device includes a radiation sensitive material and a plurality of resonance elements positioned on the radiation sensitive material. Methods for detecting a presence of a special nuclear material include positioning a radiation sensitive device in a location where special nuclear materials are to be detected and remotely interrogating the radiation sensitive device with a sensor.

  3. Characterization of causative allergens for wheat-dependent exercise-induced anaphylaxis sensitized with hydrolyzed wheat proteins in facial soap.

    Science.gov (United States)

    Yokooji, Tomoharu; Kurihara, Saki; Murakami, Tomoko; Chinuki, Yuko; Takahashi, Hitoshi; Morita, Eishin; Harada, Susumu; Ishii, Kaori; Hiragun, Makiko; Hide, Michihiro; Matsuo, Hiroaki

    2013-12-01

    In Japan, hydrolyzed wheat proteins (HWP) have been reported to cause wheat-dependent exercise-induced anaphylaxis (WDEIA) by transcutaneous sensitization using HWP-containing soap. Patients develop allergic reactions not only with soap use, but also with exercise after the intake of wheat protein (WP). ω5-Gliadin and HMW-glutenin were identified as major allergens in conventional WP-WDEIA patients. However, the allergens in HWP-WDEIA have yet to be elucidated. Sera were obtained from 22 patients with HWP-sensitized WDEIA. The allergenic activities of HWP and six recombinant wheat gluten proteins, including α/β-, γ-, ω1,2- and ω5-gliadin and low- and high molecular weight (HMW)-glutenins, were characterized by immunoblot analysis and histamine releasing test. IgE-binding epitopes were identified using arrays of overlapping peptides synthesized on SPOTs membrane. Immunoblot analysis showed that IgE antibodies (Abs) from HWP-WDEIA bound to α/β-, γ- and ω1,2-gliadin. Recombinant γ-gliadin induced significant histamine release from basophils in eight of 11 patients with HWP-WDEIA. An IgE-binding epitope "QPQQPFPQ" was identified within the primary sequence of γ-gliadin, and the deamidated peptide containing the "PEEPFP" sequence bound with IgE Abs more strongly compared to the native epitope-peptide. The epitope-peptide inhibited IgE-binding to HWP, indicating that the specific IgE to HWP cross-reacts with γ-gliadin. HWP-WDEIA patients could be sensitized to HWP containing a PEEPFP sequence, and WDEIA symptoms after WP ingestion could partly be induced by γ-gliadin. These findings could be useful to help develop tools for diagnosis and desensitization therapy for HWP-WDEIA.

  4. Computational Methods for Sensitivity and Uncertainty Analysis in Criticality Safety

    International Nuclear Information System (INIS)

    Broadhead, B.L.; Childs, R.L.; Rearden, B.T.

    1999-01-01

    Interest in the sensitivity methods that were developed and widely used in the 1970s (the FORSS methodology at ORNL among others) has increased recently as a result of potential use in the area of criticality safety data validation procedures to define computational bias, uncertainties and area(s) of applicability. Functional forms of the resulting sensitivity coefficients can be used as formal parameters in the determination of applicability of benchmark experiments to their corresponding industrial application areas. In order for these techniques to be generally useful to the criticality safety practitioner, the procedures governing their use had to be updated and simplified. This paper will describe the resulting sensitivity analysis tools that have been generated for potential use by the criticality safety community

  5. A sensitive new method of ex vivo platelet deposition

    International Nuclear Information System (INIS)

    Badimon, L.; Fuster, V.; Dewanjee, M.K.; Romero, J.C.

    1982-01-01

    In 1978, an in vivo quantitative method of platelet aggregation based on the increment of weight of a rabbit tendon when superfused with flowing blood (3 ml/min) derived from a carotid artery of a cat and reentering the contralateral jugular vein was reported. TO increase the sensitivity of the method, researches labeled platelets with indium-111 and reinjected them after two hours; then, with a gamma counter, researches quantitated the 111 In-labeled platelets deposited on the superfused rabbit tendon. Results of the radioactivity method and of the weight method were compared. Researchers found that the 111 In-labeling of platelets was more precise and reproducible method, rendering possible the use of a small amount of blood without need for reentry into the venous system

  6. Computing eigenvalue sensitivity coefficients to nuclear data based on the CLUTCH method with RMC code

    International Nuclear Information System (INIS)

    Qiu, Yishu; She, Ding; Tang, Xiao; Wang, Kan; Liang, Jingang

    2016-01-01

    Highlights: • A new algorithm is proposed to reduce memory consumption for sensitivity analysis. • The fission matrix method is used to generate adjoint fission source distributions. • Sensitivity analysis is performed on a detailed 3D full-core benchmark with RMC. - Abstract: Recently, there is a need to develop advanced methods of computing eigenvalue sensitivity coefficients to nuclear data in the continuous-energy Monte Carlo codes. One of these methods is the iterated fission probability (IFP) method, which is adopted by most of Monte Carlo codes of having the capabilities of computing sensitivity coefficients, including the Reactor Monte Carlo code RMC. Though it is accurate theoretically, the IFP method faces the challenge of huge memory consumption. Therefore, it may sometimes produce poor sensitivity coefficients since the number of particles in each active cycle is not sufficient enough due to the limitation of computer memory capacity. In this work, two algorithms of the Contribution-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method, namely, the collision-event-based algorithm (C-CLUTCH) which is also implemented in SCALE and the fission-event-based algorithm (F-CLUTCH) which is put forward in this work, are investigated and implemented in RMC to reduce memory requirements for computing eigenvalue sensitivity coefficients. While the C-CLUTCH algorithm requires to store concerning reaction rates of every collision, the F-CLUTCH algorithm only stores concerning reaction rates of every fission point. In addition, the fission matrix method is put forward to generate the adjoint fission source distribution for the CLUTCH method to compute sensitivity coefficients. These newly proposed approaches implemented in RMC code are verified by a SF96 lattice model and the MIT BEAVRS benchmark problem. The numerical results indicate the accuracy of the F-CLUTCH algorithm is the same as the C

  7. Investigation of modern methods of probalistic sensitivity analysis of final repository performance assessment models (MOSEL)

    International Nuclear Information System (INIS)

    Spiessl, Sabine; Becker, Dirk-Alexander

    2017-06-01

    Sensitivity analysis is a mathematical means for analysing the sensitivities of a computational model to variations of its input parameters. Thus, it is a tool for managing parameter uncertainties. It is often performed probabilistically as global sensitivity analysis, running the model a large number of times with different parameter value combinations. Going along with the increase of computer capabilities, global sensitivity analysis has been a field of mathematical research for some decades. In the field of final repository modelling, probabilistic analysis is regarded a key element of a modern safety case. An appropriate uncertainty and sensitivity analysis can help identify parameters that need further dedicated research to reduce the overall uncertainty, generally leads to better system understanding and can thus contribute to building confidence in the models. The purpose of the project described here was to systematically investigate different numerical and graphical techniques of sensitivity analysis with typical repository models, which produce a distinctly right-skewed and tailed output distribution and can exhibit a highly nonlinear, non-monotonic or even non-continuous behaviour. For the investigations presented here, three test models were defined that describe generic, but typical repository systems. A number of numerical and graphical sensitivity analysis methods were selected for investigation and, in part, modified or adapted. Different sampling methods were applied to produce various parameter samples of different sizes and many individual runs with the test models were performed. The results were evaluated with the different methods of sensitivity analysis. On this basis the methods were compared and assessed. This report gives an overview of the background and the applied methods. The results obtained for three typical test models are presented and explained; conclusions in view of practical applications are drawn. At the end, a recommendation

  8. Investigation of modern methods of probalistic sensitivity analysis of final repository performance assessment models (MOSEL)

    Energy Technology Data Exchange (ETDEWEB)

    Spiessl, Sabine; Becker, Dirk-Alexander

    2017-06-15

    Sensitivity analysis is a mathematical means for analysing the sensitivities of a computational model to variations of its input parameters. Thus, it is a tool for managing parameter uncertainties. It is often performed probabilistically as global sensitivity analysis, running the model a large number of times with different parameter value combinations. Going along with the increase of computer capabilities, global sensitivity analysis has been a field of mathematical research for some decades. In the field of final repository modelling, probabilistic analysis is regarded a key element of a modern safety case. An appropriate uncertainty and sensitivity analysis can help identify parameters that need further dedicated research to reduce the overall uncertainty, generally leads to better system understanding and can thus contribute to building confidence in the models. The purpose of the project described here was to systematically investigate different numerical and graphical techniques of sensitivity analysis with typical repository models, which produce a distinctly right-skewed and tailed output distribution and can exhibit a highly nonlinear, non-monotonic or even non-continuous behaviour. For the investigations presented here, three test models were defined that describe generic, but typical repository systems. A number of numerical and graphical sensitivity analysis methods were selected for investigation and, in part, modified or adapted. Different sampling methods were applied to produce various parameter samples of different sizes and many individual runs with the test models were performed. The results were evaluated with the different methods of sensitivity analysis. On this basis the methods were compared and assessed. This report gives an overview of the background and the applied methods. The results obtained for three typical test models are presented and explained; conclusions in view of practical applications are drawn. At the end, a recommendation

  9. Survey of sampling-based methods for uncertainty and sensitivity analysis

    International Nuclear Information System (INIS)

    Helton, J.C.; Johnson, J.D.; Sallaberry, C.J.; Storlie, C.B.

    2006-01-01

    Sampling-based methods for uncertainty and sensitivity analysis are reviewed. The following topics are considered: (i) definition of probability distributions to characterize epistemic uncertainty in analysis inputs (ii) generation of samples from uncertain analysis inputs (iii) propagation of sampled inputs through an analysis (iv) presentation of uncertainty analysis results, and (v) determination of sensitivity analysis results. Special attention is given to the determination of sensitivity analysis results, with brief descriptions and illustrations given for the following procedures/techniques: examination of scatterplots, correlation analysis, regression analysis, partial correlation analysis, rank transformations, statistical tests for patterns based on gridding, entropy tests for patterns based on gridding, nonparametric regression analysis, squared rank differences/rank correlation coefficient test, two-dimensional Kolmogorov-Smirnov test, tests for patterns based on distance measures, top down coefficient of concordance, and variance decomposition

  10. Survey of sampling-based methods for uncertainty and sensitivity analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean; Helton, Jon Craig; Sallaberry, Cedric J. PhD. (.; .); Storlie, Curt B. (Colorado State University, Fort Collins, CO)

    2006-06-01

    Sampling-based methods for uncertainty and sensitivity analysis are reviewed. The following topics are considered: (1) Definition of probability distributions to characterize epistemic uncertainty in analysis inputs, (2) Generation of samples from uncertain analysis inputs, (3) Propagation of sampled inputs through an analysis, (4) Presentation of uncertainty analysis results, and (5) Determination of sensitivity analysis results. Special attention is given to the determination of sensitivity analysis results, with brief descriptions and illustrations given for the following procedures/techniques: examination of scatterplots, correlation analysis, regression analysis, partial correlation analysis, rank transformations, statistical tests for patterns based on gridding, entropy tests for patterns based on gridding, nonparametric regression analysis, squared rank differences/rank correlation coefficient test, two dimensional Kolmogorov-Smirnov test, tests for patterns based on distance measures, top down coefficient of concordance, and variance decomposition.

  11. A simple and sensitive method for determination of Norfloxacin in pharmaceutical preparations

    Directory of Open Access Journals (Sweden)

    Zhuo Ye

    2015-06-01

    Full Text Available In this approach, a new voltammetric method for determination of norfloxacin was proposed with high sensitivity and wider detection linear range. The used voltammetric sensor was fabricated simply by coating a layer of graphene oxide (GO and Nafion composited film on glassy carbon electrode. The advantage of proposed method was sensitive electrochemical response for norfloxacin, which was attributed to the excellent electrical conductivity of GO and the accumulating function of Nafion under optimum experimental conditions, the present method revealed a good linear response for determination of norfloxacin in the range of 1×10-8mol/L-7×10-6 mol/L with a detection limit of 5×10-9 mol/L. The proposed method was successfully applied in the determination of norfloxacin in capsules with satisfactory results.

  12. Aquifer sensitivity to pesticide leaching: Testing a soils and hydrogeologic index method

    Science.gov (United States)

    Mehnert, E.; Keefer, D.A.; Dey, W.S.; Wehrmann, H.A.; Wilson, S.D.; Ray, C.

    2005-01-01

    For years, researchers have sought index and other methods to predict aquifer sensitivity and vulnerability to nonpoint pesticide contamination. In 1995, an index method and map were developed to define aquifer sensitivity to pesticide leaching based on a combination of soil and hydrogeologic factors. The soil factor incorporated three soil properties: hydraulic conductivity, amount of organic matter within individual soil layers, and drainage class. These properties were obtained from a digital soil association map. The hydrogeologic factor was depth to uppermost aquifer material. To test this index method, a shallow ground water monitoring well network was designed, installed, and sampled in Illinois. The monitoring wells had a median depth of 7.6 m and were located adjacent to corn and soybean fields where the only known sources of pesticides were those used in normal agricultural production. From September 1998 through February 2001, 159 monitoring wells were sampled for 14 pesticides but no pesticide metabolites. Samples were collected and analyzed to assess the distribution of pesticide occurrence across three units of aquifer sensitivity. Pesticides were detected in 18% of all samples and nearly uniformly from samples from the three units of aquifer sensitivity. The new index method did not predict pesticide occurrence because occurrence was not dependent on the combined soil and hydrogeologic factors. However, pesticide occurrence was dependent on the tested hydrogeologic factor and was three times higher in areas where the depth to the uppermost aquifer was <6 m than in areas where the depth to the uppermost aquifer was 6 to <15 m. Copyright ?? 2005 National Ground Water Association.

  13. Highly sensitive high resolution Raman spectroscopy using resonant ionization methods

    International Nuclear Information System (INIS)

    Owyoung, A.; Esherick, P.

    1984-05-01

    In recent years, the introduction of stimulated Raman methods has offered orders of magnitude improvement in spectral resolving power for gas phase Raman studies. Nevertheless, the inherent weakness of the Raman process suggests the need for significantly more sensitive techniques in Raman spectroscopy. In this we describe a new approach to this problem. Our new technique, which we call ionization-detected stimulated Raman spectroscopy (IDSRS), combines high-resolution SRS with highly-sensitive resonant laser ionization to achieve an increase in sensitivity of over three orders of magnitude. The excitation/detection process involves three sequential steps: (1) population of a vibrationally excited state via stimulated Raman pumping; (2) selective ionization of the vibrationally excited molecule with a tunable uv source; and (3) collection of the ionized species at biased electrodes where they are detected as current in an external circuit

  14. Estimation of the sensitivity of various environmental sampling methods for detection of Salmonella in duck flocks.

    Science.gov (United States)

    Arnold, Mark E; Mueller-Doblies, Doris; Gosling, Rebecca J; Martelli, Francesca; Davies, Robert H

    2015-01-01

    Reports of Salmonella in ducks in the UK currently rely upon voluntary submissions from the industry, and as there is no harmonized statutory monitoring and control programme, it is difficult to compare data from different years in order to evaluate any trends in Salmonella prevalence in relation to sampling methodology. Therefore, the aim of this project was to assess the sensitivity of a selection of environmental sampling methods, including the sampling of faeces, dust and water troughs or bowls for the detection of Salmonella in duck flocks, and a range of sampling methods were applied to 67 duck flocks. Bayesian methods in the absence of a gold standard were used to provide estimates of the sensitivity of each of the sampling methods relative to the within-flock prevalence. There was a large influence of the within-flock prevalence on the sensitivity of all sample types, with sensitivity reducing as the within-flock prevalence reduced. Boot swabs (individual and pool of four), swabs of faecally contaminated areas and whole house hand-held fabric swabs showed the overall highest sensitivity for low-prevalence flocks and are recommended for use to detect Salmonella in duck flocks. The sample type with the highest proportion positive was a pool of four hair nets used as boot swabs, but this was not the most sensitive sample for low-prevalence flocks. All the environmental sampling types (faeces swabs, litter pinches, drag swabs, water trough samples and dust) had higher sensitivity than individual faeces sampling. None of the methods consistently identified all the positive flocks, and at least 10 samples would be required for even the most sensitive method (pool of four boot swabs) to detect a 5% prevalence. The sampling of dust had a low sensitivity and is not recommended for ducks.

  15. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

    Energy Technology Data Exchange (ETDEWEB)

    Avonto, Cristina; Chittiboyina, Amar G. [National Center for Natural Products Research, Research Institute of Pharmaceutical Sciences, School of Pharmacy, The University of Mississippi, University, MS 38677 (United States); Rua, Diego [The Center for Food Safety and Applied Nutrition, US Food and Drug Administration, College Park, MD 20740 (United States); Khan, Ikhlas A., E-mail: ikhan@olemiss.edu [National Center for Natural Products Research, Research Institute of Pharmaceutical Sciences, School of Pharmacy, The University of Mississippi, University, MS 38677 (United States); Division of Pharmacognosy, Department of BioMolecular Sciences, School of Pharmacy, The University of Mississippi, University, MS 38677 (United States)

    2015-12-01

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow

  16. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

    International Nuclear Information System (INIS)

    Avonto, Cristina; Chittiboyina, Amar G.; Rua, Diego; Khan, Ikhlas A.

    2015-01-01

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow

  17. Application of perturbation methods for sensitivity analysis for nuclear power plant steam generators

    International Nuclear Information System (INIS)

    Gurjao, Emir Candeia

    1996-02-01

    The differential and GPT (Generalized Perturbation Theory) formalisms of the Perturbation Theory were applied in this work to a simplified U-tubes steam generator model to perform sensitivity analysis. The adjoint and importance equations, with the corresponding expressions for the sensitivity coefficients, were derived for this steam generator model. The system was numerically was numerically solved in a Fortran program, called GEVADJ, in order to calculate the sensitivity coefficients. A transient loss of forced primary coolant in the nuclear power plant Angra-1 was used as example case. The average and final values of functionals: secondary pressure and enthalpy were studied in relation to changes in the secondary feedwater flow, enthalpy and total volume in secondary circuit. Absolute variations in the above functionals were calculated using the perturbative methods, considering the variations in the feedwater flow and total secondary volume. Comparison with the same variations obtained via direct model showed in general good agreement, demonstrating the potentiality of perturbative methods for sensitivity analysis of nuclear systems. (author)

  18. A sensitive new microculture method for diagnosis of cutaneous leishmaniasis.

    Science.gov (United States)

    Allahverdiyev, Adil M; Uzun, Soner; Bagirova, Malahat; Durdu, Murat; Memisoglu, Hamdi R

    2004-03-01

    A sensitive microcapillary culture method (MCM) was developed for rapid diagnosis of cutaneous leishmaniasis (CL). The MCM is superior to the traditional culture method (TCM) as determined by the smaller inoculum size, the higher sensitivity for detection of promastigotes, and the more rapid time for emergence of promastigotes. With lesion amastigote loads from grade III to 0, the positive rates and the periods for promastigote emergence were 3-4-fold higher and faster with the MCM than with the TCM, e.g., 83-97% positive in 4-7 days versus 20-40% positive in 15-30 days (P = 0.0001). The higher Pco(2) and lower Po(2) and pH presumably encourage a rapid amastigote-to-promastigote differentiation and/or the survival or growth of the latter. This MCM has the advantage of simplicity, and may be suitable for diagnostic use and for parasite retrieval in many other endemic sites where parasites are known to be difficult to grow.

  19. Manufacturing error sensitivity analysis and optimal design method of cable-network antenna structures

    Science.gov (United States)

    Zong, Yali; Hu, Naigang; Duan, Baoyan; Yang, Guigeng; Cao, Hongjun; Xu, Wanye

    2016-03-01

    Inevitable manufacturing errors and inconsistency between assumed and actual boundary conditions can affect the shape precision and cable tensions of a cable-network antenna, and even result in failure of the structure in service. In this paper, an analytical sensitivity analysis method of the shape precision and cable tensions with respect to the parameters carrying uncertainty was studied. Based on the sensitivity analysis, an optimal design procedure was proposed to alleviate the effects of the parameters that carry uncertainty. The validity of the calculated sensitivities is examined by those computed by a finite difference method. Comparison with a traditional design method shows that the presented design procedure can remarkably reduce the influence of the uncertainties on the antenna performance. Moreover, the results suggest that especially slender front net cables, thick tension ties, relatively slender boundary cables and high tension level can improve the ability of cable-network antenna structures to resist the effects of the uncertainties on the antenna performance.

  20. Approximate method in estimation sensitivity responses to variations in delayed neutron energy spectra

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, J; Shin, H S; Song, T Y; Park, W S [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    Previous our numerical results in computing point kinetics equations show a possibility in developing approximations to estimate sensitivity responses of nuclear reactor. We recalculate sensitivity responses by maintaining the corrections with first order of sensitivity parameter. We present a method for computing sensitivity responses of nuclear reactor based on an approximation derived from point kinetics equations. Exploiting this approximation, we found that the first order approximation works to estimate variations in the time to reach peak power because of their linear dependence on a sensitivity parameter, and that there are errors in estimating the peak power in the first order approximation for larger sensitivity parameters. To confirm legitimacy of out approximation, these approximate results are compared with exact results obtained from out previous numerical study. 4 refs., 2 figs., 3 tabs. (Author)

  1. Approximate method in estimation sensitivity responses to variations in delayed neutron energy spectra

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, J.; Shin, H. S.; Song, T. Y.; Park, W. S. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    Previous our numerical results in computing point kinetics equations show a possibility in developing approximations to estimate sensitivity responses of nuclear reactor. We recalculate sensitivity responses by maintaining the corrections with first order of sensitivity parameter. We present a method for computing sensitivity responses of nuclear reactor based on an approximation derived from point kinetics equations. Exploiting this approximation, we found that the first order approximation works to estimate variations in the time to reach peak power because of their linear dependence on a sensitivity parameter, and that there are errors in estimating the peak power in the first order approximation for larger sensitivity parameters. To confirm legitimacy of out approximation, these approximate results are compared with exact results obtained from out previous numerical study. 4 refs., 2 figs., 3 tabs. (Author)

  2. Capillary Electrophoresis Sensitivity Enhancement Based on Adaptive Moving Average Method.

    Science.gov (United States)

    Drevinskas, Tomas; Telksnys, Laimutis; Maruška, Audrius; Gorbatsova, Jelena; Kaljurand, Mihkel

    2018-06-05

    In the present work, we demonstrate a novel approach to improve the sensitivity of the "out of lab" portable capillary electrophoretic measurements. Nowadays, many signal enhancement methods are (i) underused (nonoptimal), (ii) overused (distorts the data), or (iii) inapplicable in field-portable instrumentation because of a lack of computational power. The described innovative migration velocity-adaptive moving average method uses an optimal averaging window size and can be easily implemented with a microcontroller. The contactless conductivity detection was used as a model for the development of a signal processing method and the demonstration of its impact on the sensitivity. The frequency characteristics of the recorded electropherograms and peaks were clarified. Higher electrophoretic mobility analytes exhibit higher-frequency peaks, whereas lower electrophoretic mobility analytes exhibit lower-frequency peaks. On the basis of the obtained data, a migration velocity-adaptive moving average algorithm was created, adapted, and programmed into capillary electrophoresis data-processing software. Employing the developed algorithm, each data point is processed depending on a certain migration time of the analyte. Because of the implemented migration velocity-adaptive moving average method, the signal-to-noise ratio improved up to 11 times for sampling frequency of 4.6 Hz and up to 22 times for sampling frequency of 25 Hz. This paper could potentially be used as a methodological guideline for the development of new smoothing algorithms that require adaptive conditions in capillary electrophoresis and other separation methods.

  3. Non-animal methods to predict skin sensitization (II): an assessment of defined approaches *.

    Science.gov (United States)

    Kleinstreuer, Nicole C; Hoffmann, Sebastian; Alépée, Nathalie; Allen, David; Ashikaga, Takao; Casey, Warren; Clouet, Elodie; Cluzel, Magalie; Desprez, Bertrand; Gellatly, Nichola; Göbel, Carsten; Kern, Petra S; Klaric, Martina; Kühnl, Jochen; Martinozzi-Teissier, Silvia; Mewes, Karsten; Miyazawa, Masaaki; Strickland, Judy; van Vliet, Erwin; Zang, Qingda; Petersohn, Dirk

    2018-05-01

    Skin sensitization is a toxicity endpoint of widespread concern, for which the mechanistic understanding and concurrent necessity for non-animal testing approaches have evolved to a critical juncture, with many available options for predicting sensitization without using animals. Cosmetics Europe and the National Toxicology Program Interagency Center for the Evaluation of Alternative Toxicological Methods collaborated to analyze the performance of multiple non-animal data integration approaches for the skin sensitization safety assessment of cosmetics ingredients. The Cosmetics Europe Skin Tolerance Task Force (STTF) collected and generated data on 128 substances in multiple in vitro and in chemico skin sensitization assays selected based on a systematic assessment by the STTF. These assays, together with certain in silico predictions, are key components of various non-animal testing strategies that have been submitted to the Organization for Economic Cooperation and Development as case studies for skin sensitization. Curated murine local lymph node assay (LLNA) and human skin sensitization data were used to evaluate the performance of six defined approaches, comprising eight non-animal testing strategies, for both hazard and potency characterization. Defined approaches examined included consensus methods, artificial neural networks, support vector machine models, Bayesian networks, and decision trees, most of which were reproduced using open source software tools. Multiple non-animal testing strategies incorporating in vitro, in chemico, and in silico inputs demonstrated equivalent or superior performance to the LLNA when compared to both animal and human data for skin sensitization.

  4. Sensitive emission spectrometric method for the analysis of airborne particulate matter

    International Nuclear Information System (INIS)

    Sugimae, A.

    1975-01-01

    A rapid and sensitive emission spectrometric method for the routine analysis of airborne particulate matter collected on the glass fiber filter is reported. The method is a powder--dc arc technique involving no chemical pre-enrichment procedures. The elements--Ag, BA: Be, Bi, Cd, Co, Cr, Cu, Fe, Ga, La, Mn, Ni, Pb, Sn, V, Y, Yb, and Zn--were determined. (U.S.)

  5. Complex finite element sensitivity method for creep analysis

    International Nuclear Information System (INIS)

    Gomez-Farias, Armando; Montoya, Arturo; Millwater, Harry

    2015-01-01

    The complex finite element method (ZFEM) has been extended to perform sensitivity analysis for mechanical and structural systems undergoing creep deformation. ZFEM uses a complex finite element formulation to provide shape, material, and loading derivatives of the system response, providing an insight into the essential factors which control the behavior of the system as a function of time. A complex variable-based quadrilateral user element (UEL) subroutine implementing the power law creep constitutive formulation was incorporated within the Abaqus commercial finite element software. The results of the complex finite element computations were verified by comparing them to the reference solution for the steady-state creep problem of a thick-walled cylinder in the power law creep range. A practical application of the ZFEM implementation to creep deformation analysis is the calculation of the skeletal point of a notched bar test from a single ZFEM run. In contrast, the standard finite element procedure requires multiple runs. The value of the skeletal point is that it identifies the location where the stress state is accurate, regardless of the certainty of the creep material properties. - Highlights: • A novel finite element sensitivity method (ZFEM) for creep was introduced. • ZFEM has the capability to calculate accurate partial derivatives. • ZFEM can be used for identification of the skeletal point of creep structures. • ZFEM can be easily implemented in a commercial software, e.g. Abaqus. • ZFEM results were shown to be in excellent agreement with analytical solutions

  6. Measuring sensitivity in pharmacoeconomic studies. Refining point sensitivity and range sensitivity by incorporating probability distributions.

    Science.gov (United States)

    Nuijten, M J

    1999-07-01

    The aim of the present study is to describe a refinement of a previously presented method, based on the concept of point sensitivity, to deal with uncertainty in economic studies. The original method was refined by the incorporation of probability distributions which allow a more accurate assessment of the level of uncertainty in the model. In addition, a bootstrap method was used to create a probability distribution for a fixed input variable based on a limited number of data points. The original method was limited in that the sensitivity measurement was based on a uniform distribution of the variables and that the overall sensitivity measure was based on a subjectively chosen range which excludes the impact of values outside the range on the overall sensitivity. The concepts of the refined method were illustrated using a Markov model of depression. The application of the refined method substantially changed the ranking of the most sensitive variables compared with the original method. The response rate became the most sensitive variable instead of the 'per diem' for hospitalisation. The refinement of the original method yields sensitivity outcomes, which greater reflect the real uncertainty in economic studies.

  7. An adjoint method of sensitivity analysis for residual vibrations of structures subject to impacts

    Science.gov (United States)

    Yan, Kun; Cheng, Gengdong

    2018-03-01

    For structures subject to impact loads, the residual vibration reduction is more and more important as the machines become faster and lighter. An efficient sensitivity analysis of residual vibration with respect to structural or operational parameters is indispensable for using a gradient based optimization algorithm, which reduces the residual vibration in either active or passive way. In this paper, an integrated quadratic performance index is used as the measure of the residual vibration, since it globally measures the residual vibration response and its calculation can be simplified greatly with Lyapunov equation. Several sensitivity analysis approaches for performance index were developed based on the assumption that the initial excitations of residual vibration were given and independent of structural design. Since the resulting excitations by the impact load often depend on structural design, this paper aims to propose a new efficient sensitivity analysis method for residual vibration of structures subject to impacts to consider the dependence. The new method is developed by combining two existing methods and using adjoint variable approach. Three numerical examples are carried out and demonstrate the accuracy of the proposed method. The numerical results show that the dependence of initial excitations on structural design variables may strongly affects the accuracy of sensitivities.

  8. Isolation of uv-sensitive variants of human FL cells by a viral suicide method

    International Nuclear Information System (INIS)

    Shiomi, T.; Sato, K.

    1979-01-01

    A new method (viral suicide method) for the isolation of uv-sensitive mutants is described. Colonies of mutagenized human FL cells were infected with uv-irradiated Herpes simplex viruses and surviving ones which seemed to be deficient in host cell reactivation (HCR) were examined for their uv sensitivity. Nineteen of 238 clones examined were sensitive to uv irradiation at the time of the isolation. After recloning, four of these clones have been studied and two (UVS-1 and UVS-2) of them are stable in their uv sensitivity for 4 months in culture. uv sensitivity of UVS-1, UVS-2, and the parental FL cells are as follows: the extrapolation numbers (n) are 2.2, 2.1, and 1.8 and mean lethal doses (DO) are 2.9, 3.7, and 7.8 J/m 2 for UVS-1, UVS-2, and the parental FL cells, respectively. They are no more sensitive than FL cells to x-irradiation. The ability of HCR in UVS-2 cells is apparently lower than that in FL cells, whereas UVS-1 cells are the same as FL cells in the ability

  9. Easy method enhancing the sensitivity of a helium mass-spectrometer leak detector

    International Nuclear Information System (INIS)

    Firpo, G.; Pozzo, A.

    2004-01-01

    Commercial He mass spectrometer leak detectors usually do not provide sufficient sensitivity to perform accurate measurements of the permeation rate of He through glass. Ultrasensitive dedicated systems have adeguate sensitivity but involve high costs and complex procedures. However, both cryogenics and photomultiplier technology routinely demand this goal. Here, we propose a novel method to increase the sensitivity of commercial devices to easily measure accurate permeation rate. We modified a commercial leak detector by reducing the pumping speed at the inlet of the rotary pump, thus increasing its sensitivity by one order of magnitude. The modified detector was used to measure the leak rate of the permeation of He through the glass walls of a photomultiplier. Further improvements made to decrease the minimum detectable signal were limited by the high ultimate pressure in the spectrometer tube

  10. Isolation of UV-sensitive mutants of mouse L5178Y cells by a cell suspension spotting method

    International Nuclear Information System (INIS)

    Shiomi, T.; Hieda-Shiomi, N.; Sato, K.

    1982-01-01

    We have isolated 56 UV-sensitive mutant clones from a mouse L51 T/t line of L5178Y cells by a cell suspension spotting method. Five mutants have also been isolated from L51 T/t and L5178Y cells by the method reported by Thompson and coworkers. We divided the mutants into two groups, highly sensitive and moderately sensitive mutants, according to their sensitivity to UV irradiation. Fifty-eight mutants were highly sensitive and three were moderately sensitive to UV. The reconstruction experiments indicate that more than 90% of highly sensitive mutants were recovered by the cell suspension spotting method. Frequencies of recovered mutants highly sensitive to UV increased with increasing dose of mutagens. Recovered mutant frequency reached 10(-2) after treatment with 1.5 micrograms/ml of N-methyl-N'-nitro-N-nitrosoguanidine (MNNG) (survival 0.2%). Eight UV-sensitive mutants were divided into four complementation groups. These mutants were 2-6 times more sensitive to UV than parental L51 T/t cells in terms of D37 (dose required to reduce survival to 37%). Four representative UV-sensitive mutants which are classified into different complementation groups were examined for their sensitivity to killing by UV, 4-nitroquinoline-1-oxide (4NQO), mitomycin C (MMC), X-rays, and MNNG. All four classes of mutants were found to be cross-sensitive to UV, 4NQO, and MMC, but not sensitive to X-rays and MNNG

  11. Sensitivity-based virtual fields for the non-linear virtual fields method

    Science.gov (United States)

    Marek, Aleksander; Davis, Frances M.; Pierron, Fabrice

    2017-09-01

    The virtual fields method is an approach to inversely identify material parameters using full-field deformation data. In this manuscript, a new set of automatically-defined virtual fields for non-linear constitutive models has been proposed. These new sensitivity-based virtual fields reduce the influence of noise on the parameter identification. The sensitivity-based virtual fields were applied to a numerical example involving small strain plasticity; however, the general formulation derived for these virtual fields is applicable to any non-linear constitutive model. To quantify the improvement offered by these new virtual fields, they were compared with stiffness-based and manually defined virtual fields. The proposed sensitivity-based virtual fields were consistently able to identify plastic model parameters and outperform the stiffness-based and manually defined virtual fields when the data was corrupted by noise.

  12. Aptamer-mediated colorimetric method for rapid and sensitive detection of chloramphenicol in food.

    Science.gov (United States)

    Yan, Chao; Zhang, Jing; Yao, Li; Xue, Feng; Lu, Jianfeng; Li, Baoguang; Chen, Wei

    2018-09-15

    We report an aptamer-mediated colorimetric method for sensitive detection of chloramphenicol (CAP). The aptamer of CAP is immobilized by the hybridization with pre-immobilized capture probe in the microtiter plate. The horseradish peroxidase (HRP) is covalently attached to the aptamer by the biotin-streptavidin system for signal production. CAP will preferably bind with aptamer due to the high binding affinity, which attributes to the release of aptamer and HRP and thus, affects the optical signal intensity. Quantitative determination of CAP is successfully achieved in the wide range from 0.001 to 1000 ng/mL with detection limit of 0.0031 ng/mL, which is more sensitive than traditional immunoassays. This method is further validated by measuring the recovery of CAP spiked in two different food matrices (honey and fish). The aptamer-mediated colorimetric method can be a useful protocol for rapid and sensitive screening of CAP, and may be used as an alternative means for traditional immunoassays. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Sensitivity and Uncertainty Analysis of Coupled Reactor Physics Problems : Method Development for Multi-Physics in Reactors

    NARCIS (Netherlands)

    Perkó, Z.

    2015-01-01

    This thesis presents novel adjoint and spectral methods for the sensitivity and uncertainty (S&U) analysis of multi-physics problems encountered in the field of reactor physics. The first part focuses on the steady state of reactors and extends the adjoint sensitivity analysis methods well

  14. A sensitive method for assay of beryllium with chromazurol S and 2,2'-bipyridyl

    International Nuclear Information System (INIS)

    Buhl, F.; Kwapulinska, G.

    1980-01-01

    A spectrophotometric method of assay for microgram amounts of beryllium by means of chromazurol S in presence of 2,2'-bipyridyl was described. The latter appreciably enhances the sensitivity of the method; epsilonsub(lambda=610nm) is 5.4X10 4 . The complex compound obeys the Lambert-Beer law in the concentration range 0.002 to 0.2 ppm Be. The maximum colour intensity is immediately attained at pH 5. The molar ratio Be: CHAS: bip is 1 : 2 : 1. The suggested method is sensitive and has satisfactory selectivity when EDTA is applied as masking agent. (author)

  15. Dynamic pressure sensitivity determination with Mach number method

    Science.gov (United States)

    Sarraf, Christophe; Damion, Jean-Pierre

    2018-05-01

    Measurements of pressure in fast transient conditions are often performed even if the dynamic characteristic of the transducer are not traceable to international standards. Moreover, the question of a primary standard in dynamic pressure is still open, especially for gaseous applications. The question is to improve dynamic standards in order to respond to expressed industrial needs. In this paper, the method proposed in the EMRP IND09 ‘Dynamic’ project, which can be called the ‘ideal shock tube method’, is compared with the ‘collective standard method’ currently used in the Laboratoire de Métrologie Dynamique (LNE/ENSAM). The input is a step of pressure generated by a shock tube. The transducer is a piezoelectric pressure sensor. With the ‘ideal shock tube method’ the sensitivity of a pressure sensor is first determined dynamically. This method requires a shock tube implemented with piezoelectric shock wave detectors. The measurement of the Mach number in the tube allows an evaluation of the incident pressure amplitude of a step using a theoretical 1D model of the shock tube. Heat transfer, other actual effects and effects of the shock tube imperfections are not taken into account. The amplitude of the pressure step is then used to determine the sensitivity in dynamic conditions. The second method uses a frequency bandwidth comparison to determine pressure at frequencies from quasi-static conditions, traceable to static pressure standards, to higher frequencies (up to 10 kHz). The measurand is also a step of pressure generated by a supposed ideal shock tube or a fast-opening device. The results are provided as a transfer function with an uncertainty budget assigned to a frequency range, also deliverable frequency by frequency. The largest uncertainty in the bandwidth of comparison is used to trace the final pressure step level measured in dynamic conditions, owing that this pressure is not measurable in a steady state on a shock tube. A reference

  16. A nanosilver-based spectrophotometry method for sensitive determination of tartrazine in food samples.

    Science.gov (United States)

    Sahraei, R; Farmany, A; Mortazavi, S S

    2013-06-01

    A new method is reported for sensitive determination of tartrazine in the food samples. The method is based on the catalytic effect of silver nanoparticle (AgNPs) on the oxidation reaction of tartrazine by potassium iodate in the acetate buffer medium. The reaction is followed spectrophotometrically by measuring the change in absorbance (ΔA) at 420 nm using a fixed time method (70 s). The reaction variables were optimised in order to achieve the highest sensitivity. The thirty six criterion detection limit was 0.3 ng/mL, and the relative standard deviation for ten replicate measurements of 30 ng/mL of tartrazine was 0.98% (n=10). The method was successfully applied to the determination of tartrazine in lemon, and papaya-flavoured gelatin, candy, and in fruit syrup. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. The Role of Numerical Methods in the Sensitivity Analysis of a ...

    African Journals Online (AJOL)

    The mathematical modelling of physiochemical interaction in the framework of industrial and environmental physics which relies on an initial value problem is defined by a first order ordinary differential equation. Two numerical methods of studying sensitivity analysis of physiochemical interaction data are developed.

  18. A sensitive fluorescence quenching method for determination of bismuth with tiron

    Energy Technology Data Exchange (ETDEWEB)

    Taher, Mohammad Ali; Rahimi, Mina [Department of Chemistry, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Fazelirad, Hamid, E-mail: hamidfazelirad@gmail.com [Department of Chemistry, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Department of Chemistry, Science and Research Branch, Islamic Azad University, Yazd (Iran, Islamic Republic of); Young Researchers Society, Shahid Bahonar University of Kerman, P.O. Box 76175-133, Kerman (Iran, Islamic Republic of)

    2014-01-15

    We describe a fluorescence quenching method for determination of bismuth with tiron. The method is based on the reaction of tiron by bismuth(III) in acidic media. The influence of variables such as the pH, type of buffer, tiron concentration, reaction time and temperature were investigated. Under optimized conditions, the fluorescence quenching extent is proportional to the concentration of bismuth for Bi–tiron system at the range 0.13–2.09 μg mL{sup −1} and the detection limit is 0.05 μg mL{sup −1}. The proposed sensor presented good repeatability, evaluated in terms of relative standard deviation (R.S.D.=±0.498%) for 11 replicates. This sensitive, rapid and accurate method has been successfully applied to the determination of trace bismuth(III) in water and hair samples and certified reference materials. -- Highlights: • No previous paper report on use of fluorescence quenching for determination of Bi. • Fluorescence quenching of trion is a sensitive method for determination of Bi(III). • Under the optimum conditions the detection limit is very low (0.05 μg mL{sup −1}). • The procedure is simple and safe and has high tolerance limit to interferences.

  19. Calibration method of the pulsed X-ray relative sensitivity for ST401 plastic scintillators

    International Nuclear Information System (INIS)

    Xie Hongwei; Song Guzhou; Wang Kuilu

    2011-01-01

    The relative sensitivity calibration method of the pulsed X-ray in ST401 plastic scintillator is presented. Experimental relative sensitivity calibrations of the plastic scintillators of different thicknesses from 1 mm to 50 mm are accomplished on the 'Chenguang' pulsed X-ray source and a Co radioactive source, The uncertainty of the calibration data is evaluated, which can be treated as the experimental evidence for the relative sensitivity conversion of ST401 plastic scintillator. (authors)

  20. Application of a path sensitizing method on automated generation of test specifications for control software

    International Nuclear Information System (INIS)

    Morimoto, Yuuichi; Fukuda, Mitsuko

    1995-01-01

    An automated generation method for test specifications has been developed for sequential control software in plant control equipment. Sequential control software can be represented as sequential circuits. The control software implemented in a control equipment is designed from these circuit diagrams. In logic tests of VLSI's, path sensitizing methods are widely used to generate test specifications. But the method generates test specifications at a single time only, and can not be directly applied to sequential control software. The basic idea of the proposed method is as follows. Specifications of each logic operator in the diagrams are defined in the software design process. Therefore, test specifications of each operator in the control software can be determined from these specifications, and validity of software can be judged by inspecting all of the operators in the logic circuit diagrams. Candidates for sensitized paths, on which test data for each operator propagates, can be generated by the path sensitizing method. To confirm feasibility of the method, it was experimentally applied to control software in digital control equipment. The program could generate test specifications exactly, and feasibility of the method was confirmed. (orig.) (3 refs., 7 figs.)

  1. Overview of hybrid subspace methods for uncertainty quantification, sensitivity analysis

    International Nuclear Information System (INIS)

    Abdel-Khalik, Hany S.; Bang, Youngsuk; Wang, Congjian

    2013-01-01

    Highlights: ► We overview the state-of-the-art in uncertainty quantification and sensitivity analysis. ► We overview new developments in above areas using hybrid methods. ► We give a tutorial introduction to above areas and the new developments. ► Hybrid methods address the explosion in dimensionality in nonlinear models. ► Representative numerical experiments are given. -- Abstract: The role of modeling and simulation has been heavily promoted in recent years to improve understanding of complex engineering systems. To realize the benefits of modeling and simulation, concerted efforts in the areas of uncertainty quantification and sensitivity analysis are required. The manuscript intends to serve as a pedagogical presentation of the material to young researchers and practitioners with little background on the subjects. We believe this is important as the role of these subjects is expected to be integral to the design, safety, and operation of existing as well as next generation reactors. In addition to covering the basics, an overview of the current state-of-the-art will be given with particular emphasis on the challenges pertaining to nuclear reactor modeling. The second objective will focus on presenting our own development of hybrid subspace methods intended to address the explosion in the computational overhead required when handling real-world complex engineering systems.

  2. Overview of methods for uncertainty analysis and sensitivity analysis in probabilistic risk assessment

    International Nuclear Information System (INIS)

    Iman, R.L.; Helton, J.C.

    1985-01-01

    Probabilistic Risk Assessment (PRA) is playing an increasingly important role in the nuclear reactor regulatory process. The assessment of uncertainties associated with PRA results is widely recognized as an important part of the analysis process. One of the major criticisms of the Reactor Safety Study was that its representation of uncertainty was inadequate. The desire for the capability to treat uncertainties with the MELCOR risk code being developed at Sandia National Laboratories is indicative of the current interest in this topic. However, as yet, uncertainty analysis and sensitivity analysis in the context of PRA is a relatively immature field. In this paper, available methods for uncertainty analysis and sensitivity analysis in a PRA are reviewed. This review first treats methods for use with individual components of a PRA and then considers how these methods could be combined in the performance of a complete PRA. In the context of this paper, the goal of uncertainty analysis is to measure the imprecision in PRA outcomes of interest, and the goal of sensitivity analysis is to identify the major contributors to this imprecision. There are a number of areas that must be considered in uncertainty analysis and sensitivity analysis for a PRA: (1) information, (2) systems analysis, (3) thermal-hydraulic phenomena/fission product behavior, (4) health and economic consequences, and (5) display of results. Each of these areas and the synthesis of them into a complete PRA are discussed

  3. Non-animal methods to predict skin sensitization (I): the Cosmetics Europe database.

    Science.gov (United States)

    Hoffmann, Sebastian; Kleinstreuer, Nicole; Alépée, Nathalie; Allen, David; Api, Anne Marie; Ashikaga, Takao; Clouet, Elodie; Cluzel, Magalie; Desprez, Bertrand; Gellatly, Nichola; Goebel, Carsten; Kern, Petra S; Klaric, Martina; Kühnl, Jochen; Lalko, Jon F; Martinozzi-Teissier, Silvia; Mewes, Karsten; Miyazawa, Masaaki; Parakhia, Rahul; van Vliet, Erwin; Zang, Qingda; Petersohn, Dirk

    2018-05-01

    Cosmetics Europe, the European Trade Association for the cosmetics and personal care industry, is conducting a multi-phase program to develop regulatory accepted, animal-free testing strategies enabling the cosmetics industry to conduct safety assessments. Based on a systematic evaluation of test methods for skin sensitization, five non-animal test methods (DPRA (Direct Peptide Reactivity Assay), KeratinoSens TM , h-CLAT (human cell line activation test), U-SENS TM , SENS-IS) were selected for inclusion in a comprehensive database of 128 substances. Existing data were compiled and completed with newly generated data, the latter amounting to one-third of all data. The database was complemented with human and local lymph node assay (LLNA) reference data, physicochemical properties and use categories, and thoroughly curated. Focused on the availability of human data, the substance selection resulted nevertheless resulted in a high diversity of chemistries in terms of physico-chemical property ranges and use categories. Predictivities of skin sensitization potential and potency, where applicable, were calculated for the LLNA as compared to human data and for the individual test methods compared to both human and LLNA reference data. In addition, various aspects of applicability of the test methods were analyzed. Due to its high level of curation, comprehensiveness, and completeness, we propose our database as a point of reference for the evaluation and development of testing strategies, as done for example in the associated work of Kleinstreuer et al. We encourage the community to use it to meet the challenge of conducting skin sensitization safety assessment without generating new animal data.

  4. Hydrocoin level 3 - Testing methods for sensitivity/uncertainty analysis

    International Nuclear Information System (INIS)

    Grundfelt, B.; Lindbom, B.; Larsson, A.; Andersson, K.

    1991-01-01

    The HYDROCOIN study is an international cooperative project for testing groundwater hydrology modelling strategies for performance assessment of nuclear waste disposal. The study was initiated in 1984 by the Swedish Nuclear Power Inspectorate and the technical work was finalised in 1987. The participating organisations are regulatory authorities as well as implementing organisations in 10 countries. The study has been performed at three levels aimed at studying computer code verification, model validation and sensitivity/uncertainty analysis respectively. The results from the first two levels, code verification and model validation, have been published in reports in 1988 and 1990 respectively. This paper focuses on some aspects of the results from Level 3, sensitivity/uncertainty analysis, for which a final report is planned to be published during 1990. For Level 3, seven test cases were defined. Some of these aimed at exploring the uncertainty associated with the modelling results by simply varying parameter values and conceptual assumptions. In other test cases statistical sampling methods were applied. One of the test cases dealt with particle tracking and the uncertainty introduced by this type of post processing. The amount of results available is substantial although unevenly spread over the test cases. It has not been possible to cover all aspects of the results in this paper. Instead, the different methods applied will be illustrated by some typical analyses. 4 figs., 9 refs

  5. A simple in chemico method for testing skin sensitizing potential of chemicals using small endogenous molecules.

    Science.gov (United States)

    Nepal, Mahesh Raj; Shakya, Rajina; Kang, Mi Jeong; Jeong, Tae Cheon

    2018-06-01

    Among many of the validated methods for testing skin sensitization, direct peptide reactivity assay (DPRA) employs no cells or animals. Although no immune cells are involved in this assay, it reliably predicts the skin sensitization potential of a chemical in chemico. Herein, a new method was developed using endogenous small-molecular-weight compounds, cysteamine and glutathione, rather than synthetic peptides, to differentiate skin sensitizers from non-sensitizers with an accuracy as high as DPRA. The percent depletion of cysteamine and glutathione by test chemicals was measured by an HPLC equipped with a PDA detector. To detect small-size molecules, such as cysteamine and glutathione, a derivatization by 4-(4-dimethylaminophenylazo) benzenesulfonyl chloride (DABS-Cl) was employed prior to the HPLC analysis. Following test method optimization, a cut-off criterion of 7.14% depletion was applied to differentiate skin sensitizers from non-sensitizers in combination of the ratio of 1:25 for cysteamine:test chemical with 1:50 for glutathione:test chemical for the best predictivity among various single or combination conditions. Although overlapping HPLC peaks could not be fully resolved for some test chemicals, high levels of sensitivity (100.0%), specificity (81.8%), and accuracy (93.3%) were obtained for 30 chemicals tested, which were comparable or better than those achieved with DPRA. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Sensitivity kernels for viscoelastic loading based on adjoint methods

    Science.gov (United States)

    Al-Attar, David; Tromp, Jeroen

    2014-01-01

    kernel' Kη determines the linearized sensitivity of J to viscosity perturbations defined with respect to a laterally heterogeneous reference earth model, while the `rate-of-loading kernel' K_{dot{σ }} determines the sensitivity to variations in the time derivative of the surface load. By restricting attention to spherically symmetric viscosity perturbations, we also obtain a `radial viscosity kernel' overline{K}_{η } such that the associated contribution to δJ can be written int _{IS}overline{K}_{η }δ ln η dr, where IS denotes the subset of radii lying in solid regions. In order to illustrate this theory, we describe its numerical implementation in the case of a spherically symmetric earth model using a 1-D spectral element method, and calculate sensitivity kernels for a range of realistic observables.

  7. Prospective memory tasks: a more sensitive method for screening cognitive impairment in ALS?

    Directory of Open Access Journals (Sweden)

    Ji Ying

    2012-11-01

    Full Text Available Abstract Background Cognitive change is prevalent in patients with amyotrophic lateral sclerosis (ALS, but still lack a widely accepted and sensitive screening method. In this study, we try to find a sensitive screening battery for detecting subtle cognitive deficits in patients with ALS. Methods Eighty consecutive ALS patients and 57 matched normal controls underwent the Mini-Mental Status Examination (MMSE, the verbal fluency test (VFT, the Stroop Color Word Interference Test (CWT, and the prospective memory (PM tests, including event-based (EBPM and time-based (TBPM. Results The patients did not differ from the controls in the MMSE, the VFT and the CWT. By contrast, statistically significant differences were found in the PM tests (EBPM: P=0.043; TBPM: P Conclusions Prefrontal lobar dysfunction does exist among ALS patients and may spread from the medial to the lateral region. The PM tests seem more sensitive in ALS patients with frontotemporal dysfunction than are the classical cognitive measures.

  8. Reliability and Sensitivity Analysis for Laminated Composite Plate Using Response Surface Method

    International Nuclear Information System (INIS)

    Lee, Seokje; Kim, Ingul; Jang, Moonho; Kim, Jaeki; Moon, Jungwon

    2013-01-01

    Advanced fiber-reinforced laminated composites are widely used in various fields of engineering to reduce weight. The material property of each ply is well known; specifically, it is known that ply is less reliable than metallic materials and very sensitive to the loading direction. Therefore, it is important to consider this uncertainty in the design of laminated composites. In this study, reliability analysis is conducted using Callosum and Meatball interactions for a laminated composite plate for the case in which the tip deflection is the design requirement and the material property is a random variable. Furthermore, the efficiency and accuracy of the approximation method is identified, and a probabilistic sensitivity analysis is conducted. As a result, we can prove the applicability of the advanced design method for the stabilizer of an underwater vehicle

  9. Reliability and Sensitivity Analysis for Laminated Composite Plate Using Response Surface Method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seokje; Kim, Ingul [Chungnam National Univ., Daejeon (Korea, Republic of); Jang, Moonho; Kim, Jaeki; Moon, Jungwon [LIG Nex1, Yongin (Korea, Republic of)

    2013-04-15

    Advanced fiber-reinforced laminated composites are widely used in various fields of engineering to reduce weight. The material property of each ply is well known; specifically, it is known that ply is less reliable than metallic materials and very sensitive to the loading direction. Therefore, it is important to consider this uncertainty in the design of laminated composites. In this study, reliability analysis is conducted using Callosum and Meatball interactions for a laminated composite plate for the case in which the tip deflection is the design requirement and the material property is a random variable. Furthermore, the efficiency and accuracy of the approximation method is identified, and a probabilistic sensitivity analysis is conducted. As a result, we can prove the applicability of the advanced design method for the stabilizer of an underwater vehicle.

  10. Using the Delphi method to develop nursing-sensitive quality indicators for the NICU.

    Science.gov (United States)

    Chen, Lin; Huang, Li-Hua; Xing, Mei-Yuan; Feng, Zhi-Xian; Shao, Le-Wen; Zhang, Mei-Yun; Shao, Rong-Ya

    2017-02-01

    To develop nursing-sensitive quality indicators consistent with current medical practices in Chinese neonatal intensive care units. The development of nursing-sensitive quality indicators has become a top priority in nursing management. To the best of our knowledge, there has been no objective, scientific and sensitive evaluation of the quality of neonatal intensive care unit nursing in China. A modified Delphi technique was used to seek opinions from experts about what should be used and prioritised as indicators of quality care in neonatal intensive care unit nursing. Based on a literature review, we identified 21 indicators of nursing-sensitive quality in the neonatal intensive care unit. Our group of 11 consultants chose 13 indicators to be discussed using the Delphi method. In October and November 2014, 39 neonatal intensive care unit experts in 18 tertiary hospitals spread across six provinces participated in two rounds of Delphi panels. Of the 13 indicators discussed, 11 were identified as indicators of nursing-sensitive quality in the neonatal intensive care unit: rate of nosocomial infections, rate of accidental endotracheal extubation, rate of errors in medication administration, rate of treatment for pain, rate of peripheral venous extravasation, rate of compliance with handwashing techniques, incidence of pressure ulcers, incidence of noise, the bed-to-care ratio, the proportion of nurses with greater than five years neonatal intensive care unit experience and incidence of retinopathy. The 11 neonatal intensive care unit nursing-sensitive indicators identified by the Delphi method integrated with basic Chinese practices provide a basis for nursing management and the monitoring of nursing quality. This study identified nursing-sensitive quality indicators for neonatal intensive care unit care that are suitable for current clinical practice in China. © 2016 John Wiley & Sons Ltd.

  11. Perturbative methods applied for sensitive coefficients calculations in thermal-hydraulic systems

    International Nuclear Information System (INIS)

    Andrade Lima, F.R. de

    1993-01-01

    The differential formalism and the Generalized Perturbation Theory (GPT) are applied to sensitivity analysis of thermal-hydraulics problems related to pressurized water reactor cores. The equations describing the thermal-hydraulic behavior of these reactors cores, used in COBRA-IV-I code, are conveniently written. The importance function related to the response of interest and the sensitivity coefficient of this response with respect to various selected parameters are obtained by using Differential and Generalized Perturbation Theory. The comparison among the results obtained with the application of these perturbative methods and those obtained directly with the model developed in COBRA-IV-I code shows a very good agreement. (author)

  12. EPR method for the detection of sensitization in stainless steels

    International Nuclear Information System (INIS)

    Clarke, W.L.; Cowan, R.L.

    1980-01-01

    The overall objective of the program was to improve the reliability of reactor system piping by increasing knowledge of failure causing mechanisms and by enhancing the capability for design evaluation and analysis. Toward the attainment of that objective, a technique has been developed to measure the degree of sensitization quantitatively in thermally treated AISI-304, -304L, -316 and 316L stainless steels. The Electrochemical Potentiokinetic Reactivation (EPR) test was developed because of an industrial need for a rapid, nondestructive, quantitative field test which could be used for assessing sensitization in reactor components. The EPR method consists of developing potentiokinetic curves on a polarized sample obtained by controlled potential sweep from the passive to the active region (reactivation) in a specific electrolyte; details of the test technique have been reported

  13. Perturbative methods for sensitivity calculation in safety problems of nuclear reactors: state-of-the-art

    International Nuclear Information System (INIS)

    Lima, Fernando R.A.; Lira, Carlos A.B.O.; Gandini, Augusto

    1995-01-01

    During the last two decades perturbative methods became an efficient tool to perform sensitivity analysis in nuclear reactor safety problems. In this paper, a comparative study taking into account perturbation formalisms (Diferential and Matricial Mthods and generalized Perturbation Theory - GPT) is considered. Then a few number of applications are described to analyze the sensitivity of some functions relavant to thermal hydraulics designs or safety analysis of nuclear reactor cores and steam generators. The behaviours of the nuclear reactor cores and steam generators are simulated, respectively, by the COBRA-IV-I and GEVAP codes. Results of sensitivity calculations have shown a good agreement when compared to those obtained directly by using the mentioned codes. So, a significative computational time safe can be obtained with perturbative methods performing sensitivity analysis in nuclear power plants. (author). 25 refs., 5 tabs

  14. Technical Note: Method of Morris effectively reduces the computational demands of global sensitivity analysis for distributed watershed models

    Directory of Open Access Journals (Sweden)

    J. D. Herman

    2013-07-01

    Full Text Available The increase in spatially distributed hydrologic modeling warrants a corresponding increase in diagnostic methods capable of analyzing complex models with large numbers of parameters. Sobol' sensitivity analysis has proven to be a valuable tool for diagnostic analyses of hydrologic models. However, for many spatially distributed models, the Sobol' method requires a prohibitive number of model evaluations to reliably decompose output variance across the full set of parameters. We investigate the potential of the method of Morris, a screening-based sensitivity approach, to provide results sufficiently similar to those of the Sobol' method at a greatly reduced computational expense. The methods are benchmarked on the Hydrology Laboratory Research Distributed Hydrologic Model (HL-RDHM over a six-month period in the Blue River watershed, Oklahoma, USA. The Sobol' method required over six million model evaluations to ensure reliable sensitivity indices, corresponding to more than 30 000 computing hours and roughly 180 gigabytes of storage space. We find that the method of Morris is able to correctly screen the most and least sensitive parameters with 300 times fewer model evaluations, requiring only 100 computing hours and 1 gigabyte of storage space. The method of Morris proves to be a promising diagnostic approach for global sensitivity analysis of highly parameterized, spatially distributed hydrologic models.

  15. Singularity-sensitive gauge-based radar rainfall adjustment methods for urban hydrological applications

    Directory of Open Access Journals (Sweden)

    L.-P. Wang

    2015-09-01

    Full Text Available Gauge-based radar rainfall adjustment techniques have been widely used to improve the applicability of radar rainfall estimates to large-scale hydrological modelling. However, their use for urban hydrological applications is limited as they were mostly developed based upon Gaussian approximations and therefore tend to smooth off so-called "singularities" (features of a non-Gaussian field that can be observed in the fine-scale rainfall structure. Overlooking the singularities could be critical, given that their distribution is highly consistent with that of local extreme magnitudes. This deficiency may cause large errors in the subsequent urban hydrological modelling. To address this limitation and improve the applicability of adjustment techniques at urban scales, a method is proposed herein which incorporates a local singularity analysis into existing adjustment techniques and allows the preservation of the singularity structures throughout the adjustment process. In this paper the proposed singularity analysis is incorporated into the Bayesian merging technique and the performance of the resulting singularity-sensitive method is compared with that of the original Bayesian (non singularity-sensitive technique and the commonly used mean field bias adjustment. This test is conducted using as case study four storm events observed in the Portobello catchment (53 km2 (Edinburgh, UK during 2011 and for which radar estimates, dense rain gauge and sewer flow records, as well as a recently calibrated urban drainage model were available. The results suggest that, in general, the proposed singularity-sensitive method can effectively preserve the non-normality in local rainfall structure, while retaining the ability of the original adjustment techniques to generate nearly unbiased estimates. Moreover, the ability of the singularity-sensitive technique to preserve the non-normality in rainfall estimates often leads to better reproduction of the urban

  16. Singularity-sensitive gauge-based radar rainfall adjustment methods for urban hydrological applications

    Science.gov (United States)

    Wang, L.-P.; Ochoa-Rodríguez, S.; Onof, C.; Willems, P.

    2015-09-01

    Gauge-based radar rainfall adjustment techniques have been widely used to improve the applicability of radar rainfall estimates to large-scale hydrological modelling. However, their use for urban hydrological applications is limited as they were mostly developed based upon Gaussian approximations and therefore tend to smooth off so-called "singularities" (features of a non-Gaussian field) that can be observed in the fine-scale rainfall structure. Overlooking the singularities could be critical, given that their distribution is highly consistent with that of local extreme magnitudes. This deficiency may cause large errors in the subsequent urban hydrological modelling. To address this limitation and improve the applicability of adjustment techniques at urban scales, a method is proposed herein which incorporates a local singularity analysis into existing adjustment techniques and allows the preservation of the singularity structures throughout the adjustment process. In this paper the proposed singularity analysis is incorporated into the Bayesian merging technique and the performance of the resulting singularity-sensitive method is compared with that of the original Bayesian (non singularity-sensitive) technique and the commonly used mean field bias adjustment. This test is conducted using as case study four storm events observed in the Portobello catchment (53 km2) (Edinburgh, UK) during 2011 and for which radar estimates, dense rain gauge and sewer flow records, as well as a recently calibrated urban drainage model were available. The results suggest that, in general, the proposed singularity-sensitive method can effectively preserve the non-normality in local rainfall structure, while retaining the ability of the original adjustment techniques to generate nearly unbiased estimates. Moreover, the ability of the singularity-sensitive technique to preserve the non-normality in rainfall estimates often leads to better reproduction of the urban drainage system

  17. Increased sensitivity of OSHA method analysis of diacetyl and 2,3-pentanedione in air.

    Science.gov (United States)

    LeBouf, Ryan; Simmons, Michael

    2017-05-01

    Gas chromatography/mass spectrometry (GC/MS) operated in selected ion monitoring mode was used to enhance the sensitivity of OSHA Methods 1013/1016 for measuring diacetyl and 2,3-pentanedione in air samples. The original methods use flame ionization detection which cannot achieve the required sensitivity to quantify samples at or below the NIOSH recommended exposure limits (REL: 5 ppb for diacetyl and 9.3 ppb for 2,3-pentanedione) when sampling for both diacetyl and 2,3-pentanedione. OSHA Method 1012 was developed to measure diacetyl at lower levels but requires an electron capture detector, and a sample preparation time of 36 hours. Using GC/MS allows detection of these two alpha-diketones at lower levels than OSHA Method 1012 for diacetyl and OSHA Method 1016 for 2,3-pentanedione. Acetoin and 2,3-hexanedione may also be measured using this technique. Method quantification limits were 1.1 ppb for diacetyl (22% of the REL), 1.1 ppb for 2,3-pentanedione (12% of the REL), 1.1 ppb for 2,3-hexanedione, and 2.1 ppb for acetoin. Average extraction efficiencies above the limit of quantitation were 100% for diacetyl, 92% for 2,3-pentanedione, 89% for 2,3-hexanedione, and 87% for acetoin. Mass spectrometry with OSHA Methods 1013/1016 could be used by analytical laboratories to provide more sensitive and accurate measures of exposure to diacetyl and 2,3-pentanedione.

  18. New computer-aided diagnosis of dementia using positron emission tomography: brain regional sensitivity-mapping method.

    Directory of Open Access Journals (Sweden)

    Akihiro Kakimoto

    Full Text Available PURPOSE: We devised a new computer-aided diagnosis method to segregate dementia using one estimated index (Total Z score derived from the Brodmann area (BA sensitivity map on the stereotaxic brain atlas. The purpose of this study is to investigate its accuracy to differentiate patients with Alzheimer's disease (AD or mild cognitive impairment (MCI from normal adults (NL. METHODS: We studied 101 adults (NL: 40, AD: 37, MCI: 24 who underwent (18FDG positron emission tomography (PET measurement. We divided NL and AD groups into two categories: a training group with (Category A and a test group without (Category B clinical information. In Category A, we estimated sensitivity by comparing the standard uptake value per BA (SUVR between NL and AD groups. Then, we calculated a summated index (Total Z score by utilizing the sensitivity-distribution maps and each BA z-score to segregate AD patterns. To confirm the validity of this method, we examined the accuracy in Category B. Finally, we applied this method to MCI patients. RESULTS: In Category A, we found that the sensitivity and specificity of differentiation between NL and AD were all 100%. In Category B, those were 100% and 95%, respectively. Furthermore, we found this method attained 88% to differentiate AD-converters from non-converters in MCI group. CONCLUSIONS: The present automated computer-aided evaluation method based on a single estimated index provided good accuracy for differential diagnosis of AD and MCI. This good differentiation power suggests its usefulness not only for dementia diagnosis but also in a longitudinal study.

  19. New Computer-Aided Diagnosis of Dementia Using Positron Emission Tomography: Brain Regional Sensitivity-Mapping Method

    Science.gov (United States)

    Kakimoto, Akihiro; Kamekawa, Yuichi; Ito, Shigeru; Yoshikawa, Etsuji; Okada, Hiroyuki; Nishizawa, Sadahiko; Minoshima, Satoshi; Ouchi, Yasuomi

    2011-01-01

    Purpose We devised a new computer-aided diagnosis method to segregate dementia using one estimated index (Total Z score) derived from the Brodmann area (BA) sensitivity map on the stereotaxic brain atlas. The purpose of this study is to investigate its accuracy to differentiate patients with Alzheimer's disease (AD) or mild cognitive impairment (MCI) from normal adults (NL). Methods We studied 101 adults (NL: 40, AD: 37, MCI: 24) who underwent 18FDG positron emission tomography (PET) measurement. We divided NL and AD groups into two categories: a training group with (Category A) and a test group without (Category B) clinical information. In Category A, we estimated sensitivity by comparing the standard uptake value per BA (SUVR) between NL and AD groups. Then, we calculated a summated index (Total Z score) by utilizing the sensitivity-distribution maps and each BA z-score to segregate AD patterns. To confirm the validity of this method, we examined the accuracy in Category B. Finally, we applied this method to MCI patients. Results In Category A, we found that the sensitivity and specificity of differentiation between NL and AD were all 100%. In Category B, those were 100% and 95%, respectively. Furthermore, we found this method attained 88% to differentiate AD-converters from non-converters in MCI group. Conclusions The present automated computer-aided evaluation method based on a single estimated index provided good accuracy for differential diagnosis of AD and MCI. This good differentiation power suggests its usefulness not only for dementia diagnosis but also in a longitudinal study. PMID:21966405

  20. Effect of irradiation on the Porphyromonas gingivalis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Hee; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    2008-03-15

    The aim of this study was to observe a direct effect of irradiation on the periodontopathic Porphyromonas gingivalis (P. gingivalis). P. gingivalis 2561 was exposed to irradiation with a single absorbed dose of 10, 20, 30, and 40 Gy. Changes in viability and antibiotic sensitivity, morphology, transcription, and protein profile of the bacterium after irradiation were examined by pour plating method, disc diffusion method, transmission electron microscopy, RT-PCR, and immunoblot, respectively. Viability of irradiated P. gingivalis drastically reduced as irradiation dose was increased. Irradiated P. gingivalis was found to have become more sensitive to antibiotics as radiation dose was increased. With observation under the transmission electron microscope, the number of morphologically abnormal cells was increased with increasing of irradiation dose. In RT-PCR, decrease in the expression of fim A and sod was observed in irradiated P. gingivalis. In immunoblot, change of profile in irradiated P. gingivalis was found in a number of proteins including 43-kDa fimbrillin. These results suggest that irradiation may affect the cell integrity of P. gingivalis, which is manifested by the change in cell morphology and antibiotic sensitivity, affecting viability of the bacterium.

  1. Effect of irradiation on the Porphyromonas gingivalis

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2008-01-01

    The aim of this study was to observe a direct effect of irradiation on the periodontopathic Porphyromonas gingivalis (P. gingivalis). P. gingivalis 2561 was exposed to irradiation with a single absorbed dose of 10, 20, 30, and 40 Gy. Changes in viability and antibiotic sensitivity, morphology, transcription, and protein profile of the bacterium after irradiation were examined by pour plating method, disc diffusion method, transmission electron microscopy, RT-PCR, and immunoblot, respectively. Viability of irradiated P. gingivalis drastically reduced as irradiation dose was increased. Irradiated P. gingivalis was found to have become more sensitive to antibiotics as radiation dose was increased. With observation under the transmission electron microscope, the number of morphologically abnormal cells was increased with increasing of irradiation dose. In RT-PCR, decrease in the expression of fim A and sod was observed in irradiated P. gingivalis. In immunoblot, change of profile in irradiated P. gingivalis was found in a number of proteins including 43-kDa fimbrillin. These results suggest that irradiation may affect the cell integrity of P. gingivalis, which is manifested by the change in cell morphology and antibiotic sensitivity, affecting viability of the bacterium.

  2. Community sensitization and decision-making for trial participation: a mixed-methods study from The Gambia.

    Science.gov (United States)

    Dierickx, Susan; O'Neill, Sarah; Gryseels, Charlotte; Immaculate Anyango, Edna; Bannister-Tyrrell, Melanie; Okebe, Joseph; Mwesigwa, Julia; Jaiteh, Fatou; Gerrets, René; Ravinetto, Raffaella; D'Alessandro, Umberto; Peeters Grietens, Koen

    2017-08-16

    Ensuring individual free and informed decision-making for research participation is challenging. It is thought that preliminarily informing communities through 'community sensitization' procedures may improve individual decision-making. This study set out to assess the relevance of community sensitization for individual decision-making in research participation in rural Gambia. This anthropological mixed-methods study triangulated qualitative methods and quantitative survey methods in the context of an observational study and a clinical trial on malaria carried out by the Medical Research Council Unit Gambia. Although 38.7% of the respondents were present during sensitization sessions, 91.1% of the respondents were inclined to participate in the trial when surveyed after the sensitization and prior to the informed consent process. This difference can be explained by the informal transmission of information within the community after the community sensitization, expectations such as the benefits of participation based on previous research experiences, and the positive reputation of the research institute. Commonly mentioned barriers to participation were blood sampling and the potential disapproval of the household head. Community sensitization is effective in providing first-hand, reliable information to communities as the information is cascaded to those who could not attend the sessions. However, further research is needed to assess how the informal spread of information further shapes people's expectations, how the process engages with existing social relations and hierarchies (e.g. local political power structures; permissions of heads of households) and how this influences or changes individual consent. © 2017 The Authors Developing World Bioethics Published by John Wiley & Sons Ltd.

  3. A new sensitive method for detecting human endogenous (leukocyte) pyrogen.

    Science.gov (United States)

    Bodel, P; Miller, H

    1978-03-01

    Endogenous, or leukocyte pyrogen (EP), the mediator of fever, is currently detected by injection of pyrogen-containing supernatants into rabbits. This assay has been of little value in the study of human fever because it required injection of relatively large amounts of pyrogen. We now report that injection of medium containing human EP produces fever in mice. Supernatant from 1 c 10(5) granulocytes, stimulated by phagocytosis of staphylococci and incubated overnight, or 1 x 10(4) monocytes similarly treated, produce clear pyrogenic responses. This method for detecting EP is about 100-fold more sensitive than the rabbit assay, and it appears to be specific for EP. Preliminary studies of EP released by small samples of needle liver biopsies from febrile and afebrile patients suggests that this sensitive assay may be useful for investigations into the mechanisms of clinical fever.

  4. Diagnostic capabilities of non-treponemal and treponemal reactions in the early forms of syphilis.

    OpenAIRE

    Zakharov, S. V.

    2017-01-01

    A comparative analysis of the sensitivity and specificity of immunoblotting against other non-treponemal and treponemal reactions was carried out in 215 patients with early forms of syphilis. A high diagnostic efficiency of immunoblotting in patients with early latent syphilis was established. It was found that only in case of primary syphilis, immunoblotting is inferior to Immunofluorescence reaction; this test can be used for differential diagnosis between hidden syphilis and false positive...

  5. Application of perturbation methods and sensitivity analysis to water hammer problems in hydraulic networks

    International Nuclear Information System (INIS)

    Balino, Jorge L.; Larreteguy, Axel E.; Andrade Lima, Fernando R.

    1995-01-01

    The differential method was applied to the sensitivity analysis for water hammer problems in hydraulic networks. Starting from the classical water hammer equations in a single-phase liquid with friction, the state vector comprising the piezometric head and the velocity was defined. Applying the differential method the adjoint operator, the adjoint equations with the general form of their boundary conditions, and the general form of the bilinear concomitant were calculated. The discretized adjoint equations and the corresponding boundary conditions were programmed and solved by using the so called method of characteristics. As an example, a constant-level tank connected through a pipe to a valve discharging to atmosphere was considered. The bilinear concomitant was calculated for this particular case. The corresponding sensitivity coefficients due to the variation of different parameters by using both the differential method and the response surface generated by the computer code WHAT were also calculated. The results obtained with these methods show excellent agreement. (author). 11 refs, 2 figs, 2 tabs

  6. Deterministic sensitivity analysis of two-phase flow systems: forward and adjoint methods. Final report

    International Nuclear Information System (INIS)

    Cacuci, D.G.

    1984-07-01

    This report presents a self-contained mathematical formalism for deterministic sensitivity analysis of two-phase flow systems, a detailed application to sensitivity analysis of the homogeneous equilibrium model of two-phase flow, and a representative application to sensitivity analysis of a model (simulating pump-trip-type accidents in BWRs) where a transition between single phase and two phase occurs. The rigor and generality of this sensitivity analysis formalism stem from the use of Gateaux (G-) differentials. This report highlights the major aspects of deterministic (forward and adjoint) sensitivity analysis, including derivation of the forward sensitivity equations, derivation of sensitivity expressions in terms of adjoint functions, explicit construction of the adjoint system satisfied by these adjoint functions, determination of the characteristics of this adjoint system, and demonstration that these characteristics are the same as those of the original quasilinear two-phase flow equations. This proves that whenever the original two-phase flow problem is solvable, the adjoint system is also solvable and, in principle, the same numerical methods can be used to solve both the original and adjoint equations

  7. Highly sensitive luminescence method of scandium determination in the products of metallurgical reprocessing

    International Nuclear Information System (INIS)

    Matveets, M.A.; Akhmetova, S.D.

    1988-01-01

    Highly sensitive reaction of scandium with 1,10-phenanthroline and eosin is used for the development of luminescence method of its determination in metallurgical products. The effect of interfering elements is eliminated by scandium extraction with monocarboxylic acids. The method permits to determine scandium content from 5 x 10 -5 % (Sr 0.15 - 0.25)

  8. Sensitive spectrophotometric methods for determination of some organophosphorus pesticides in vegetable samples

    Directory of Open Access Journals (Sweden)

    MAGDA A. AKL

    2010-03-01

    Full Text Available Three rapid, simple, reproducible and sensitive spectrophotometric methods (A, B and C are described for the determination of two organophosphorus pesticides, (malathion and dimethoate in formulations and vegetable samples. The methods A and B involve the addition of an excess of Ce4+ into sulphuric acid medium and the determination of the unreacted oxidant by decreasing the red color of chromotrope 2R (C2R at a suitable lmax = 528 nm for method A, or a decrease in the orange pink color of rhodamine 6G (Rh6G at a suitable lmax = = 525 nm. The method C is based on the oxidation of malathion or dimethoate with the slight excess of N-bromosuccinimide (NBS and the determination of unreacted oxidant by reacting it with amaranth dye (AM in hydrochloric acid medium at a suitable lmax = 520 nm. A regression analysis of Beer-Lambert plots showed a good correlation in the concentration range of 0.1-4.2 μg mL−1. The apparent molar absorptivity, Sandell sensitivity, the detection and quantification limits were calculated. For more accurate analysis, Ringbom optimum concentration ranges are 0.25-4.0 μg mL−1. The developed methods were successfully applied to the determination of malathion, and dimethoate in their formulations and environmental vegetable samples.

  9. Comparison of the Sensitivity of Three Methods for the Early Diagnosis of Sporotrichosis in Cats.

    Science.gov (United States)

    Silva, J N; Miranda, L H M; Menezes, R C; Gremião, I D F; Oliveira, R V C; Vieira, S M M; Conceição-Silva, F; Ferreiro, L; Pereira, S A

    2018-04-01

    Sporotrichosis is caused by species of fungi within the Sporothrix schenckii complex that infect man and animals. In Rio de Janeiro, Brazil, an epidemic has been observed since 1998, with most of the cases being related to transmission from infected cats. Although the definitive diagnosis of feline sporotrichosis is made by fungal culture, cytopathological and histopathological examinations are used routinely, because the long culture period may delay treatment onset. However, alternative methods are desirable in cases of low fungal burden. Immunohistochemistry (IHC) has been described as a sensitive method for diagnosing human and canine sporotrichosis, but there are no reports of its application to cats. The aim of this study was to analyse the sensitivity of cytopathological examination (Quick Panoptic method), histopathology (Grocott silver stain) and anti-Sporothrix IHC by blinded comparisons, using fungal culture as the reference standard. Samples were collected from 184 cats with sporotrichosis that exhibited skin ulcers. The sensitivities of Grocott silver stain, cytopathological examination and IHC were 91.3%, 87.0% and 88.6%, respectively. Grocott silver stain showed the best performance. IHC showed high sensitivity, as did cytopathological examination and these may be considered as alternative methodologies. When the three methods were combined, the diagnosis was established in 180 (97.8%) out of 184 cases. Taken together, these findings indicate the need to implement these methods as routine tools for the early diagnosis of sporotrichosis in cats, notably when fungal culture is not available. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. An UPLC-MS/MS method for highly sensitive high-throughput analysis of phytohormones in plant tissues

    Directory of Open Access Journals (Sweden)

    Balcke Gerd Ulrich

    2012-11-01

    Full Text Available Abstract Background Phytohormones are the key metabolites participating in the regulation of multiple functions of plant organism. Among them, jasmonates, as well as abscisic and salicylic acids are responsible for triggering and modulating plant reactions targeted against pathogens and herbivores, as well as resistance to abiotic stress (drought, UV-irradiation and mechanical wounding. These factors induce dramatic changes in phytohormone biosynthesis and transport leading to rapid local and systemic stress responses. Understanding of underlying mechanisms is of principle interest for scientists working in various areas of plant biology. However, highly sensitive, precise and high-throughput methods for quantification of these phytohormones in small samples of plant tissues are still missing. Results Here we present an LC-MS/MS method for fast and highly sensitive determination of jasmonates, abscisic and salicylic acids. A single-step sample preparation procedure based on mixed-mode solid phase extraction was efficiently combined with essential improvements in mobile phase composition yielding higher efficiency of chromatographic separation and MS-sensitivity. This strategy resulted in dramatic increase in overall sensitivity, allowing successful determination of phytohormones in small (less than 50 mg of fresh weight tissue samples. The method was completely validated in terms of analyte recovery, sensitivity, linearity and precision. Additionally, it was cross-validated with a well-established GC-MS-based procedure and its applicability to a variety of plant species and organs was verified. Conclusion The method can be applied for the analyses of target phytohormones in small tissue samples obtained from any plant species and/or plant part relying on any commercially available (even less sensitive tandem mass spectrometry instrumentation.

  11. Short ensembles: An Efficient Method for Discerning Climate-relevant Sensitivities in Atmospheric General Circulation Models

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Hui; Rasch, Philip J.; Zhang, Kai; Qian, Yun; Yan, Huiping; Zhao, Chun

    2014-09-08

    This paper explores the feasibility of an experimentation strategy for investigating sensitivities in fast components of atmospheric general circulation models. The basic idea is to replace the traditional serial-in-time long-term climate integrations by representative ensembles of shorter simulations. The key advantage of the proposed method lies in its efficiency: since fewer days of simulation are needed, the computational cost is less, and because individual realizations are independent and can be integrated simultaneously, the new dimension of parallelism can dramatically reduce the turnaround time in benchmark tests, sensitivities studies, and model tuning exercises. The strategy is not appropriate for exploring sensitivity of all model features, but it is very effective in many situations. Two examples are presented using the Community Atmosphere Model version 5. The first example demonstrates that the method is capable of characterizing the model cloud and precipitation sensitivity to time step length. A nudging technique is also applied to an additional set of simulations to help understand the contribution of physics-dynamics interaction to the detected time step sensitivity. In the second example, multiple empirical parameters related to cloud microphysics and aerosol lifecycle are perturbed simultaneously in order to explore which parameters have the largest impact on the simulated global mean top-of-atmosphere radiation balance. Results show that in both examples, short ensembles are able to correctly reproduce the main signals of model sensitivities revealed by traditional long-term climate simulations for fast processes in the climate system. The efficiency of the ensemble method makes it particularly useful for the development of high-resolution, costly and complex climate models.

  12. Synthesis of SnS nanoparticles by SILAR method for quantum dot-sensitized solar cells.

    Science.gov (United States)

    Tsukigase, Hiroki; Suzuki, Yoshikazu; Berger, Marie-Hélène; Sagawa, Takashi; Yoshikawa, Susumu

    2011-03-01

    SnS-sensitized TiO2 electrodes were applied in quantum dot-sensitized solar cells (QDSSCs) which are environmentally more favorable than conventional Cd or Pb-chalcogenide-sensitized electrodes. SnS nanoparticles were well-distributed over the surface of TiO2 nanoparticles by the successive ionic layer adsorption and reaction (SILAR) method. Deposited SnS nanoparticles had diameter about 3 nm. Under AM1.5 irradiation with 100 mW/cm2 light intensity (at 1 sun), the energy conversion efficiency of obtained cells reached a value of 0.21% (0.25 cm2) at SILAR coating cycles of 5. In addition, the photovoltaic performance was improved by additional ZnS coating on the surface of SnS-sensitized TiO2 electrodes.

  13. Short ensembles: an efficient method for discerning climate-relevant sensitivities in atmospheric general circulation models

    Directory of Open Access Journals (Sweden)

    H. Wan

    2014-09-01

    Full Text Available This paper explores the feasibility of an experimentation strategy for investigating sensitivities in fast components of atmospheric general circulation models. The basic idea is to replace the traditional serial-in-time long-term climate integrations by representative ensembles of shorter simulations. The key advantage of the proposed method lies in its efficiency: since fewer days of simulation are needed, the computational cost is less, and because individual realizations are independent and can be integrated simultaneously, the new dimension of parallelism can dramatically reduce the turnaround time in benchmark tests, sensitivities studies, and model tuning exercises. The strategy is not appropriate for exploring sensitivity of all model features, but it is very effective in many situations. Two examples are presented using the Community Atmosphere Model, version 5. In the first example, the method is used to characterize sensitivities of the simulated clouds to time-step length. Results show that 3-day ensembles of 20 to 50 members are sufficient to reproduce the main signals revealed by traditional 5-year simulations. A nudging technique is applied to an additional set of simulations to help understand the contribution of physics–dynamics interaction to the detected time-step sensitivity. In the second example, multiple empirical parameters related to cloud microphysics and aerosol life cycle are perturbed simultaneously in order to find out which parameters have the largest impact on the simulated global mean top-of-atmosphere radiation balance. It turns out that 12-member ensembles of 10-day simulations are able to reveal the same sensitivities as seen in 4-year simulations performed in a previous study. In both cases, the ensemble method reduces the total computational time by a factor of about 15, and the turnaround time by a factor of several hundred. The efficiency of the method makes it particularly useful for the development of

  14. Simplified methods of evaluating colonies for levels of Varroa Sensitive Hygiene (VSH)

    Science.gov (United States)

    Varroa sensitive hygiene (VSH) is a trait of honey bees, Apis mellifera, that supports resistance to varroa mites, Varroa destructor. Components of VSH were evaluated to identify simple methods for selection of the trait. Varroa mite population growth was measured in colonies with variable levels of...

  15. Diagnostic capabilities of non-treponemal and treponemal reactions in the early forms of syphilis

    Directory of Open Access Journals (Sweden)

    Zakharov S.V.

    2017-12-01

    Full Text Available A comparative analysis of the sensitivity and specificity of immunoblotting against other non-treponemal and treponemal reactions was carried out in 215 patients with early forms of syphilis. A high diagnostic efficiency of immunoblotting in patients with early latent syphilis was established. It was found that only in case of primary syphilis, immunoblotting is inferior to Immunofluorescence reaction; this test can be used for differential diagnosis between hidden syphilis and false positive reactions to syphilis.

  16. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

    Science.gov (United States)

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization integrated approaches combining different chemical, biological and in silico methods are recommended to r...

  17. 'PSA-SPN' - A Parameter Sensitivity Analysis Method Using Stochastic Petri Nets: Application to a Production Line System

    International Nuclear Information System (INIS)

    Labadi, Karim; Saggadi, Samira; Amodeo, Lionel

    2009-01-01

    The dynamic behavior of a discrete event dynamic system can be significantly affected for some uncertain changes in its decision parameters. So, parameter sensitivity analysis would be a useful way in studying the effects of these changes on the system performance. In the past, the sensitivity analysis approaches are frequently based on simulation models. In recent years, formal methods based on stochastic process including Markov process are proposed in the literature. In this paper, we are interested in the parameter sensitivity analysis of discrete event dynamic systems by using stochastic Petri nets models as a tool for modelling and performance evaluation. A sensitivity analysis approach based on stochastic Petri nets, called PSA-SPN method, will be proposed with an application to a production line system.

  18. Lake and Reservoir Evaporation Estimation: Sensitivity Analysis and Ranking Existing Methods

    Directory of Open Access Journals (Sweden)

    maysam majidi

    2016-02-01

    were acquired from the Doosti Dam weather station. Relative humidity, wind speed, atmospheric pressure and precipitation were acquired from the Pol−Khatoon weather station. Dew point temperature and sunshine data were collected from the Sarakhs weather station. Lake area was estimated from hypsometric curve in relation to lake level data. Temperature measurements were often performed in 16−day periods or biweekly from September 2011 to September 2012. Temperature profile of the lake (required for lake evaporation estimation was measured at different points of the reservoir using a portable multi−meter. The eighteen existing methods were compared and ranked based on Bowen ratio energy balance method (BREB. Results and Discussion: The estimated annual evaporation values by all of the applied methods in this study, ranged from 21 to 113mcm (million cubic meters. BREB annual evaporation obtained value was equal to 69.86mcm and evaporation rate averaged 5.47mm d-1 during the study period. According to the results, there is a relatively large difference between the obtained evaporation values from the adopted methods. The sensitivity analysis of evaporation methods for some input parameters indicated that the Hamon method (Eq. 16 was the most sensitive to the input parameters followed by the Brutsaert−Stricker and BREB, and radiation−temperature methods (Makkink, Jensen−Haise and Stephen−Stewart had the least sensitivity to input data. Besides, the air temperature, solar radiation (sunshine data, water surface temperature and wind speed data had the most effect on lake evaporation estimations, respectively. Finally, all evaporation estimation methods in this study have been ranked based on RMSD values. On a daily basis, the Jensen−Haise and the Makkink (solar radiation, temperature group, Penman (Combination group and Hamon (temperature, day length group methods had a relatively reasonable performance. As the results on a monthly scale, the Jensen−Haise and

  19. Effect of parameters in moving average method for event detection enhancement using phase sensitive OTDR

    Science.gov (United States)

    Kwon, Yong-Seok; Naeem, Khurram; Jeon, Min Yong; Kwon, Il-bum

    2017-04-01

    We analyze the relations of parameters in moving average method to enhance the event detectability of phase sensitive optical time domain reflectometer (OTDR). If the external events have unique frequency of vibration, then the control parameters of moving average method should be optimized in order to detect these events efficiently. A phase sensitive OTDR was implemented by a pulsed light source, which is composed of a laser diode, a semiconductor optical amplifier, an erbium-doped fiber amplifier, a fiber Bragg grating filter, and a light receiving part, which has a photo-detector and high speed data acquisition system. The moving average method is operated with the control parameters: total number of raw traces, M, number of averaged traces, N, and step size of moving, n. The raw traces are obtained by the phase sensitive OTDR with sound signals generated by a speaker. Using these trace data, the relation of the control parameters is analyzed. In the result, if the event signal has one frequency, then the optimal values of N, n are existed to detect the event efficiently.

  20. A Terbium Sensitized Luminescence Method for the Assay of Flubiprofen in Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Salma M.Z. Al-Kindy

    2014-12-01

    Full Text Available A sensitive time-resolved luminescence method for the determination of flubiprofen (FLP in methanol and in aqueous solution is described. The method is based on the luminescence sensitization of terbium (Tb3+ by the formation of a ternary complex with FLP in the presence of 4,7 diphenyl 1,10 phenanthroline (DPP as co-ligand, and Tween-20 as surfactant. The signal for Tb-FLP-DPP was monitored at λex  = 285 nm and λem  = 552 nm. Optimum conditions for the formation of the complex in an aqueous system were TRIS buffer, pH 8.0, DPP (2.5Å~10−7  M, Tween-20 (0.30% and 4Å~10-5  mol L-1  of Tb3+  which allowed the determination of 20–1000 ng mL-1  of FLP with a limit of detection (LOD of 10 ng mL-1 . The relative standard deviations of the method ranged between 0.6 and 1.4% indicating excellent reproducibility of the method. The proposed method was successfully applied for the assays of FLP in pharmaceutical formulations and spiked tap water samples with average recoveries of 87% – 95%.

  1. Energetic materials and methods of tailoring electrostatic discharge sensitivity of energetic materials

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, Michael A.; Heaps, Ronald J.; Wallace, Ronald S.; Pantoya, Michelle L.; Collins, Eric S.

    2016-11-01

    An energetic material comprising an elemental fuel, an oxidizer or other element, and a carbon nanofiller or carbon fiber rods, where the carbon nanofiller or carbon fiber rods are substantially homogeneously dispersed in the energetic material. Methods of tailoring the electrostatic discharge sensitivity of an energetic material are also disclosed.

  2. In vivo conditions to identify Prkci phosphorylation targets using the analog-sensitive kinase method in zebrafish.

    Directory of Open Access Journals (Sweden)

    Elena Cibrián Uhalte

    Full Text Available Protein kinase C iota is required for various cell biological processes including epithelial tissue polarity and organ morphogenesis. To gain mechanistic insight into different roles of this kinase, it is essential to identify specific substrate proteins in their cellular context. The analog-sensitive kinase method provides a powerful tool for the identification of kinase substrates under in vivo conditions. However, it has remained a major challenge to establish screens based on this method in multicellular model organisms. Here, we report the methodology for in vivo conditions using the analog-sensitive kinase method in a genetically-tractable vertebrate model organism, the zebrafish. With this approach, kinase substrates can uniquely be labeled in the developing zebrafish embryo using bulky ATPγS analogs which results in the thiophosphorylation of substrates. The labeling of kinase substrates with a thiophosphoester epitope differs from phosphoesters that are generated by all other kinases and allows for an enrichment of thiophosphopeptides by immunoaffinity purification. This study provides the foundation for using the analog-sensitive kinase method in the context of complex vertebrate development, physiology, or disease.

  3. A method for hardening or curing adhesives for flocking thermally sensitive substrata by means of an electron-beam

    International Nuclear Information System (INIS)

    Nablo, S.V.; Fussa, A.D.

    1975-01-01

    The invention relates to a method for hardening or curing adhesives for flocking thermally sensitive substrata by means of an electron-beam. That method consists in accurately adjusting the parameters of irradiation by an electron-beam and the beam velocity so as to obtain, a very rapid hardening of adhesives used for fixing flocking materials, or the like, to thermally sensitive substrate. That can be applied to hardening or curing adhesives for flocking thermally-sensitive substrata which normally restrict the hardening rate [fr

  4. Allergenicity and cross-reactivity of booklice (Liposcelis bostrichophila): a common household insect pest in Japan.

    Science.gov (United States)

    Fukutomi, Yuma; Kawakami, Yuji; Taniguchi, Masami; Saito, Akemi; Fukuda, Azumi; Yasueda, Hiroshi; Nakazawa, Takuya; Hasegawa, Maki; Nakamura, Hiroyuki; Akiyama, Kazuo

    2012-01-01

    Booklice (Liposcelis bostrichophila) are a common household insect pest distributed worldwide. Particularly in Japan, they infest 'tatami' mats and are the most frequently detected insect among all detectable insects, present at a frequency of about 90% in dust samples. Although it has been hypothesized that they are an important indoor allergen, studies on their allergenicity have been limited. To clarify the allergenicity of booklice and the cross-reactivity of this insect allergen with allergens of other insects, patients sensitized to booklice were identified from 185 Japanese adults with allergic asthma using skin tests and IgE-ELISA. IgE-inhibition analysis, immunoblotting and immunoblotting-inhibition analysis were performed using sera from these patients. Allergenic proteins contributing to specific sensitization to booklice were identified by two-dimensional electrophoresis and two-dimensional immunoblotting. The booklouse-specific IgE antibody was detected in sera from 41 patients (22% of studied patients). IgE inhibition analysis revealed that IgE reactivity to the booklouse allergen in the sera from one third of booklouse-sensitized patients was not inhibited by preincubation with extracts from any other environmental insects in this study. Immunoblotting identified a 26-kD protein from booklouse extract as the allergenic protein contributing to specific sensitization to booklice. The amino acid sequence of peptide fragments of this protein showed no homology to those of previously described allergenic proteins, indicating that this protein is a new allergen. Sensitization to booklice was relatively common and specific sensitization to this insect not related to insect panallergy was indicated in this population. Copyright © 2011 S. Karger AG, Basel.

  5. Efficiencies of Dye-Sensitized Solar Cells using Ferritin-Encapsulated Quantum Dots with Various Staining Methods

    Science.gov (United States)

    Perez, Luis

    Dye-sensitized solar cells (DSSC) have the potential to replace traditional and cost-inefficient crystalline silicon or ruthenium solar cells. This can only be accomplished by optimizing DSSC's energy efficiency. One of the major components in a dye-sensitized solar cell is the porous layer of titanium dioxide. This layer is coated with a molecular dye that absorbs sunlight. The research conducted for this paper focuses on the different methods used to dye the porous TiO2 layer with ferritin-encapsulated quantum dots. Multiple anodes were dyed using a method known as SILAR which involves deposition through alternate immersion in two different solutions. The efficiencies of DSSCs with ferritin-encapsulated lead sulfide dye deposited using SILAR were subsequently compared against the efficiencies produced by cells using the traditional immersion method. It was concluded that both methods resulted in similar efficiencies (? .074%) however, the SILAR method dyed the TiO2 coating significantly faster than the immersion method. On a related note, our experiments concluded that conducting 2 SILAR cycles yields the highest possible efficiency for this particular binding method. National Science Foundation.

  6. Estimating the Capacity of Urban Transportation Networks with an Improved Sensitivity Based Method

    Directory of Open Access Journals (Sweden)

    Muqing Du

    2015-01-01

    Full Text Available The throughput of a given transportation network is always of interest to the traffic administrative department, so as to evaluate the benefit of the transportation construction or expansion project before its implementation. The model of the transportation network capacity formulated as a mathematic programming with equilibrium constraint (MPEC well defines this problem. For practical applications, a modified sensitivity analysis based (SAB method is developed to estimate the solution of this bilevel model. The high-efficient origin-based (OB algorithm is extended for the precise solution of the combined model which is integrated in the network capacity model. The sensitivity analysis approach is also modified to simplify the inversion of the Jacobian matrix in large-scale problems. The solution produced in every iteration of SAB is restrained to be feasible to guarantee the success of the heuristic search. From the numerical experiments, the accuracy of the derivatives for the linear approximation could significantly affect the converging of the SAB method. The results also show that the proposed method could obtain good suboptimal solutions from different starting points in the test examples.

  7. An efficient computational method for global sensitivity analysis and its application to tree growth modelling

    International Nuclear Information System (INIS)

    Wu, Qiong-Li; Cournède, Paul-Henry; Mathieu, Amélie

    2012-01-01

    Global sensitivity analysis has a key role to play in the design and parameterisation of functional–structural plant growth models which combine the description of plant structural development (organogenesis and geometry) and functional growth (biomass accumulation and allocation). We are particularly interested in this study in Sobol's method which decomposes the variance of the output of interest into terms due to individual parameters but also to interactions between parameters. Such information is crucial for systems with potentially high levels of non-linearity and interactions between processes, like plant growth. However, the computation of Sobol's indices relies on Monte Carlo sampling and re-sampling, whose costs can be very high, especially when model evaluation is also expensive, as for tree models. In this paper, we thus propose a new method to compute Sobol's indices inspired by Homma–Saltelli, which improves slightly their use of model evaluations, and then derive for this generic type of computational methods an estimator of the error estimation of sensitivity indices with respect to the sampling size. It allows the detailed control of the balance between accuracy and computing time. Numerical tests on a simple non-linear model are convincing and the method is finally applied to a functional–structural model of tree growth, GreenLab, whose particularity is the strong level of interaction between plant functioning and organogenesis. - Highlights: ► We study global sensitivity analysis in the context of functional–structural plant modelling. ► A new estimator based on Homma–Saltelli method is proposed to compute Sobol indices, based on a more balanced re-sampling strategy. ► The estimation accuracy of sensitivity indices for a class of Sobol's estimators can be controlled by error analysis. ► The proposed algorithm is implemented efficiently to compute Sobol indices for a complex tree growth model.

  8. Testing the sensitivity of Nested PCR method to detect Aspergillus fumigates in experimentally infected Sputum samples

    International Nuclear Information System (INIS)

    Ramadan, A.; Soukkaria, S.

    2013-01-01

    Fungal infections caused by Aspergillus species generally are occupying a second place among invasive fungal infections in the world, especially A. fumigatus, which is considered the main cause of invasive Aspergillosis (IA). Although IA rarely infects immunocompetent individuals, however, it can lead to death in immunocompromised patients. Therefore, it is necessary to diagnose the infection early in order to treat the disease efficiently. However, the conventional diagnostic tools, currently used to detect infections, has low sensitivity and reliability. Polymerase chain reaction (PCR) technology distribution as a molecular and high sensitive technology has allowed us to make comparative study between sensitivity of traditional currently used diagnostic method and Nested-PCR, the result of the study of sputum samples that experimentally infected with different concentrations of A.fumigatus spores ramping from 10 to10 6 spore/ml, have high sensitivity and specificity of Nested-PCR in detecting the lower concentrations, comparing with traditional diagnostic method (culture on Sabouraud media) that were negative in all concetrations. (author)

  9. A rapid detection method for policy-sensitive amines real-time supervision.

    Science.gov (United States)

    Zhang, Haixu; Shu, Jinian; Yang, Bo; Zhang, Peng; Ma, Pengkun

    2018-02-01

    Many organic amines that comprise a benzene ring are policy-sensitive because of their toxicity and links to social harm. However, to date, detection of such compounds mainly relies on offline methods. This study proposes an online pptv (parts per trillion by volume) level of detection method for amines, using the recently-built vacuum ultraviolet photoionization mass spectrometer (VUV-PIMS) combined with a new doping technique. Thus, the dichloromethane doping-assisted photoionization mass spectra of aniline, benzylamine, phenethylamine, amphetamine, and their structural isomers were recorded. The dominant characteristic mass peaks for all amines are those afforded by protonated amines and the amino radical-loss. The signal intensities of the amines were enhanced by 60-130 times compared to those recorded without doping assistance. Under 10s detection time, the sensitivities of aniline and benzylamine in the gas phase were determined as 4.0 and 2.7 countspptv -1 , with limits of detection (LODs) of 36 and 22 pptv, respectively. Notably, the detection efficiency of this method can be tenfold better in future applications since the ion transmission efficiency of the mass spectrometer was intentionally reduced to ~ 10% in this study. Therefore, dichloromethane doping-assisted photoionization mass spectrometry has proven to be a highly promising on-line approach to amine detection in environmental and judicial supervision and shows great potential for application in the biological field. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Adjoint Parameter Sensitivity Analysis for the Hydrodynamic Lattice Boltzmann Method with Applications to Design Optimization

    DEFF Research Database (Denmark)

    Pingen, Georg; Evgrafov, Anton; Maute, Kurt

    2009-01-01

    We present an adjoint parameter sensitivity analysis formulation and solution strategy for the lattice Boltzmann method (LBM). The focus is on design optimization applications, in particular topology optimization. The lattice Boltzmann method is briefly described with an in-depth discussion...

  11. A simple, reproducible and sensitive spectrophotometric method to estimate microalgal lipids

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yimin [ChELSI Institute, Department of Chemical and Biological Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom); Vaidyanathan, Seetharaman, E-mail: s.vaidyanathan@sheffield.ac.uk [ChELSI Institute, Department of Chemical and Biological Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom)

    2012-04-29

    Highlights: Black-Right-Pointing-Pointer FAs released from lipids form complex with Cu-TEA in chloroform. Black-Right-Pointing-Pointer The FA-Cu-TEA complex gives strong absorbance at 260 nm. Black-Right-Pointing-Pointer The absorbance is sensitive and independent of C-atom number in the FAs (10-18). Black-Right-Pointing-Pointer Microalgal lipid extract and pure FA (such as C16) can both be used as standards. - Abstract: Quantification of total lipids is a necessity for any study of lipid production by microalgae, especially given the current interest in microalgal carbon capture and biofuels. In this study, we employed a simple yet sensitive method to indirectly measure the lipids in microalgae by measuring the fatty acids (FA) after saponification. The fatty acids were reacted with triethanolamine-copper salts (TEA-Cu) and the ternary TEA-Cu-FA complex was detected at 260 nm using a UV-visible spectrometer without any colour developer. The results showed that this method could be used to analyse low levels of lipids in the range of nano-moles from as little as 1 mL of microalgal culture. Furthermore, the structure of the TEA-Cu-FA complex and related reaction process are proposed to better understand this assay. There is no special instrument required and the method is very reproducible. To the best of our knowledge, this is the first report of the use of UV absorbance of copper salts with FA as a method to estimate lipids in algal cultures. It will pave the way for a more convenient assay of lipids in microalgae and can readily be expanded for estimating lipids in other biological systems.

  12. A simple, reproducible and sensitive spectrophotometric method to estimate microalgal lipids

    International Nuclear Information System (INIS)

    Chen Yimin; Vaidyanathan, Seetharaman

    2012-01-01

    Highlights: ► FAs released from lipids form complex with Cu–TEA in chloroform. ► The FA–Cu–TEA complex gives strong absorbance at 260 nm. ► The absorbance is sensitive and independent of C-atom number in the FAs (10–18). ► Microalgal lipid extract and pure FA (such as C16) can both be used as standards. - Abstract: Quantification of total lipids is a necessity for any study of lipid production by microalgae, especially given the current interest in microalgal carbon capture and biofuels. In this study, we employed a simple yet sensitive method to indirectly measure the lipids in microalgae by measuring the fatty acids (FA) after saponification. The fatty acids were reacted with triethanolamine–copper salts (TEA–Cu) and the ternary TEA–Cu–FA complex was detected at 260 nm using a UV–visible spectrometer without any colour developer. The results showed that this method could be used to analyse low levels of lipids in the range of nano-moles from as little as 1 mL of microalgal culture. Furthermore, the structure of the TEA–Cu–FA complex and related reaction process are proposed to better understand this assay. There is no special instrument required and the method is very reproducible. To the best of our knowledge, this is the first report of the use of UV absorbance of copper salts with FA as a method to estimate lipids in algal cultures. It will pave the way for a more convenient assay of lipids in microalgae and can readily be expanded for estimating lipids in other biological systems.

  13. Other notable protein blotting methods: a brief review.

    Science.gov (United States)

    Kurien, Biji T; Scofield, R Hal

    2015-01-01

    Proteins have been transferred from the gel to the membrane by a variety of methods. These include vacuum blotting, centrifuge blotting, electroblotting of proteins to Teflon tape and membranes for N- and C-terminal sequence analysis, multiple tissue blotting, a two-step transfer of low- and high-molecular-weight proteins, acid electroblotting onto activated glass, membrane-array method for the detection of human intestinal bacteria in fecal samples, protein microarray using a new black cellulose nitrate support, electrotransfer using square wave alternating voltage for enhanced protein recovery, polyethylene glycol-mediated significant enhancement of the immunoblotting transfer, parallel protein chemical processing before and during western blot and the molecular scanner concept, electronic western blot of matrix-assisted laser desorption/ionization mass spectrometric-identified polypeptides from parallel processed gel-separated proteins, semidry electroblotting of peptides and proteins from acid-urea polyacrylamide gels, transfer of silver-stained proteins from polyacrylamide gels to polyvinylidene difluoride (PVDF) membranes, and the display of K(+) channel proteins on a solid nitrocellulose support for assaying toxin binding. The quantification of proteins bound to PVDF membranes by elution of CBB, clarification of immunoblots on PVDF for transmission densitometry, gold coating of nonconductive membranes before matrix-assisted laser desorption/ionization tandem mass spectrometric analysis to prevent charging effect for analysis of peptides from PVDF membranes, and a simple method for coating native polysaccharides onto nitrocellulose are some of the methods involving either the manipulation of membranes with transferred proteins or just a passive transfer of antigens to membranes. All these methods are briefly reviewed in this chapter.

  14. Investigation of colistin sensitivity via three different methods in Acinetobacter baumannii isolates with multiple antibiotic resistance.

    Science.gov (United States)

    Sinirtaş, Melda; Akalin, Halis; Gedikoğlu, Suna

    2009-09-01

    In recent years there has been an increase in life-threatening infections caused by Acinetobacter baumannii with multiple antibiotic resistance, which has lead to the use of polymyxins, especially colistin, being reconsidered. The aim of this study was to investigate the colistin sensitivity of A. baumannii isolates with multiple antibiotic resistance via different methods, and to evaluate the disk diffusion method for colistin against multi-resistant Acinetobacter isolates, in comparison to the E-test and Phoenix system. The study was carried out on 100 strains of A. baumannii (colonization or infection) isolated from the microbiological samples of different patients followed in the clinics and intensive care units of Uludağ University Medical School between the years 2004 and 2005. Strains were identified and characterized for their antibiotic sensitivity by Phoenix system (Becton Dickinson, Sparks, MD, USA). In all studied A. baumannii strains, susceptibility to colistin was determined to be 100% with the disk diffusion, E-test, and broth microdilution methods. Results of the E-test and broth microdilution method, which are accepted as reference methods, were found to be 100% consistent with the results of the disk diffusion tests; no very major or major error was identified upon comparison of the tests. The sensitivity and the positive predictive value of the disk diffusion method were found to be 100%. Colistin resistance in A. baumannii was not detected in our region, and disk diffusion method results are in accordance with those of E-test and broth microdilution methods.

  15. LLNA variability: An essential ingredient for a comprehensive assessment of non-animal skin sensitization test methods and strategies.

    Science.gov (United States)

    Hoffmann, Sebastian

    2015-01-01

    The development of non-animal skin sensitization test methods and strategies is quickly progressing. Either individually or in combination, the predictive capacity is usually described in comparison to local lymph node assay (LLNA) results. In this process the important lesson from other endpoints, such as skin or eye irritation, to account for variability reference test results - here the LLNA - has not yet been fully acknowledged. In order to provide assessors as well as method and strategy developers with appropriate estimates, we investigated the variability of EC3 values from repeated substance testing using the publicly available NICEATM (NTP Interagency Center for the Evaluation of Alternative Toxicological Methods) LLNA database. Repeat experiments for more than 60 substances were analyzed - once taking the vehicle into account and once combining data over all vehicles. In general, variability was higher when different vehicles were used. In terms of skin sensitization potential, i.e., discriminating sensitizer from non-sensitizers, the false positive rate ranged from 14-20%, while the false negative rate was 4-5%. In terms of skin sensitization potency, the rate to assign a substance to the next higher or next lower potency class was approx.10-15%. In addition, general estimates for EC3 variability are provided that can be used for modelling purposes. With our analysis we stress the importance of considering the LLNA variability in the assessment of skin sensitization test methods and strategies and provide estimates thereof.

  16. Radioimmunoassay (RIA), a highly specific, extremely sensitive quantitative method of analysis

    Energy Technology Data Exchange (ETDEWEB)

    Strecker, H; Hachmann, H; Seidel, L [Farbwerke Hoechst A.G., Frankfurt am Main (Germany, F.R.). Radiochemisches Lab.

    1979-02-01

    Radioimmunoassay is an analytical method combining the sensitivity of radioactivity measurements and the specificity of the antigen-antibody-reaction. Thus, substances can be measured in concentrations as low as picograms per milliliter serum besides a millionfold excess of otherwise disturbing material (for example in serum). The method is simple to perform and is at present mainly used in the field of endocrinology. Further areas of possible application are in the diagnosis of infectious disease, drug research, environmental protection, forensic medicine as well as general analytics. Quantities of radioactivity, exclusively used in vitro, are in the nano-Curie range. Therefore the radiation dose is negligible.

  17. Study of the AISI 347 austenitic stainless steel sensitization through the potentiokinetic reactivation method

    International Nuclear Information System (INIS)

    Teodoro, Celso Antonio; Wolynec, Stephan

    1996-01-01

    The sensitization kinetics of AISI 347 austenitic stainless steel samples, removed from a forged bar, was investigated with an electrochemical potentiokinetic reactivation method. After the solution anneal at 1140 deg C, the steel was submitted to sensitization treatments at 550 deg C, 670 deg C, 790 deg C and 910 deg C during times that varied from 1 h to 62 h. It was found that samples treated at 550 deg C, 670 deg C and 790 deg C become sensitized. The activation energy was found to be 124 kJ/mol. The observed behaviour was discussed in terms of both carbon retention in solution after the solution anneal and kinetics of carbon combination with chromium and niobium. (author)

  18. Dye-Sensitized Solar Cells with Optimal Gel Electrolyte Using the Taguchi Design Method

    Directory of Open Access Journals (Sweden)

    Jenn-Kai Tsai

    2013-01-01

    Full Text Available The Taguchi method was adopted to determine the optimal gel electrolyte used in dye-sensitized solar cells (DSSCs. Since electrolyte is a very important factor in fabrication of high performance and long-term stability DSSCs, to find the optimal composition of gel electrolyte is desired. In this paper, the common ingredients used in the liquid electrolyte were chosen. The ingredients then mixed with cheap ionic liquids and poly(vinylidenefluoride-co-hexafluoropropylene (PVDF-HFP were added to form colloidal electrolyte (gel. The optimal composition of each materials in the gel electrolyte determined by Taguchi method consists of 0.03 M I2, 0.15 M KI, 0.6 M LiI, 0.5 M 4-tertbutylpyridine (TBP, and 10% PVDF-HFP dissolved in the acetonitrile and 3-methoxypropionitrile (MPN solution with volume ratio of 2 : 1. The short circuit current density of 14.11 mA/cm2, the conversion efficiency (η of 5.52%, and the lifetime of over 110 days were observed for the dye-sensitized solar cell assembled with optimal gel electrolyte. The lifetime increases 10 times when compared with the conventional dye-sensitized solar cell assembled with liquid electrolyte.

  19. Sensitivity and uncertainty analyses applied to criticality safety validation, methods development. Volume 1

    International Nuclear Information System (INIS)

    Broadhead, B.L.; Hopper, C.M.; Childs, R.L.; Parks, C.V.

    1999-01-01

    This report presents the application of sensitivity and uncertainty (S/U) analysis methodologies to the code/data validation tasks of a criticality safety computational study. Sensitivity and uncertainty analysis methods were first developed for application to fast reactor studies in the 1970s. This work has revitalized and updated the available S/U computational capabilities such that they can be used as prototypic modules of the SCALE code system, which contains criticality analysis tools currently used by criticality safety practitioners. After complete development, simplified tools are expected to be released for general use. The S/U methods that are presented in this volume are designed to provide a formal means of establishing the range (or area) of applicability for criticality safety data validation studies. The development of parameters that are analogous to the standard trending parameters forms the key to the technique. These parameters are the D parameters, which represent the differences by group of sensitivity profiles, and the ck parameters, which are the correlation coefficients for the calculational uncertainties between systems; each set of parameters gives information relative to the similarity between pairs of selected systems, e.g., a critical experiment and a specific real-world system (the application)

  20. An improved electrochemiluminescence polymerase chain reaction method for highly sensitive detection of plant viruses

    International Nuclear Information System (INIS)

    Tang Yabing; Xing Da; Zhu Debin; Liu Jinfeng

    2007-01-01

    Recently, we have reported an electrochemiluminescence polymerase chain reaction (ECL-PCR) method for detection of genetically modified organisms. The ECL-PCR method was further improved in the current study by introducing a multi-purpose nucleic acid sequence that was specific to the tris(bipyridine) ruthenium (TBR) labeled probe, into the 5' terminal of the primers. The method was applied to detect plant viruses. Conserved sequence of the plant viruses was amplified by PCR. The product was hybridized with a biotin labeled probe and a TBR labeled probe. The hybridization product was separated by streptavidin-coated magnetic beads, and detected by measuring the ECL signals of the TBR labeled. Under the optimized conditions, the experiment results show that the detection limit is 50 fmol of PCR products, and the signal-to-noise ratio is in excess of 14.6. The method was used to detect banana streak virus, banana bunchy top virus, and papaya leaf curl virus. The experiment results show that this method could reliably identity viruses infected plant samples. The improved ECL-PCR approach has higher sensitivity and lower cost than previous approach. It can effectively detect the plant viruses with simplicity, stability, and high sensitivity

  1. Evaluación de dos pruebas de inmunoblot con antígeno hidatídico de caprino y ovino para el diagnóstico de equinococosis humana Evaluation of two immunoblot tests with goat and sheep hydatid antigen for human echinococcosis diagnosis

    Directory of Open Access Journals (Sweden)

    Eduardo Miranda

    2010-06-01

    Full Text Available Para estimar el valor diagnóstico del antígeno hidatídico de caprino y de ovino en la prueba de inmunoblot para echinococosis quística, se usó 135 sueros, de los cuales 70 procedían de pacientes con hidatidosis confirmada por el hallazgo de protoescólices y membrana en el estudio anatomopatológico con la pieza quirúrgica; 45 a pacientes con otras enfermedades parasitarias y 20 a personas aparentemente sanas. La sensibilidad, la especificidad, el valor predictivo positivo y negativo de la prueba de inmunoblot, con antígeno hidatídico de caprino fue de 92,8%, 100%, 100% y 92,8%, respectivamente; mientras que de ovino fueron 91,4%, 95,3%, 95,5% y 91,1 %, respectivamente. El índice kappa fue de 0,93 para el antígeno caprino y de 0,86 con el ovino en relación con el estudio anatomopatológico. Se recomienda el uso de ambos antígenos para el diagnóstico serológico de la equinococosis quística humana.To estimate the diagnosis value of goat and ovine antigen for echinococcosis immunoblot test, 135 serums were used, of which 70 were coming from patients with hydatid disease confirmed by the finding of proto scolex and membrane in the pathology study of surgical piece, 45 from patients with other parasitic diseases and 20 apparently healthy people. The sensitivity, the specificity, positive and negative predictive value of immunoblot test, with hidatyd antigen of goat was of 92.8%, 100%, 100%, 92.8%, respectively, than for ovine antigen was 91.4%, 95.3%, 95.5%, 91.1%, respectively. Kappa index was 0.93 for goat antigen and 0.86 with sheep in relation to the pathological study. We recommended the use of both antigens for the serologic diagnosis of human echinococcosis.

  2. Rapid, sensitive and cost effective method for isolation of viral DNA from feacal samples of dogs

    Directory of Open Access Journals (Sweden)

    Savi.

    2010-06-01

    Full Text Available A simple method for viral DNA extraction using chelex resin was developed. The method used was eco-friendly and cost effective compared to other methods such as phenol chloroform method which use health hazardous organic reagents. Further, a polymerase chain reaction (PCR based detection of canine parvovirus (CPV using primers from conserved region of VP2 gene was developed. To increase the sensitivity and specificity of reaction, nested PCR was designed. PCR reaction was optimized to amplify 747bp product of VP2 gene. The assay can be completed in few hours and doesn’t need hazardous chemicals. Thus, the sample preparation using chelating resin along with nested PCR seems to be a sensitive, specific and practical method for the detection of CPV in diarrhoeal feacal samples. [Vet. World 2010; 3(3.000: 105-106

  3. Sensitive method for the determination of nitrated polycyclic aromatic hydrocarbons in the human diet

    Energy Technology Data Exchange (ETDEWEB)

    Siegmund, B.; Weiss, R.; Pfannhauser, W. [Graz Univ. of Technology (Austria). Inst. of Food Chemistry

    2003-01-01

    The presence of nitrated polycyclic aromatic hydrocarbons (nitro-PAHs) as contaminants in foods is nowadays a legitimate cause of concern, as they are reported to be strong direct-acting mutagens and carcinogens that may pose a risk to human health. Nevertheless, their concentrations in foods are in the ultra-trace region. In this study, we present a very sensitive analytical method for the determination of this compound class in complex food matrices. Special emphasis was put on sample extraction and clean up. Recoveries of 75% could be obtained for 1- and 2-nitronaphthalene; for all other compounds investigated the recoveries were {>=}94%. The determination of the compounds was performed by gas chromatography-mass spectrometry. The results show that the use of negative chemical ionization (NCI) increases the sensitivity by one order of magnitude in comparison to electron impact ionization (EI) (limits of detection 0.07-0.25 {mu}g kg{sup -1} for EI and 0.01-0.02 {mu}g kg{sup -1} for NCI). The influence of the sample matrix on the sensitivity of the method is demonstrated with extracts of a sample from a duplicate diet study. Due to the lack of a certified reference material the suitability of the method is demonstrated with pumpkin seed oil that was spiked with nitro-PAHs at two different concentration levels. (orig.)

  4. A counterselection method for Lactococcus lactis genome editing based on class IIa bacteriocin sensitivity.

    Science.gov (United States)

    Wan, Xing; Usvalampi, Anne M; Saris, Per E J; Takala, Timo M

    2016-11-01

    In this paper, we present a new counterselection method for deleting fragments from Lactococcus lactis chromosome. The method uses a non-replicating plasmid vector, which integrates into the chromosome and makes the cell sensitive to bacteriocins. The integration vector carries pUC ori functional in Escherichia coli but not in L. lactis, an erythromycin resistance gene for selecting single crossover integrants, and two fragments from L. lactis chromosome for homologous recombinations. In addition, the integration vector is equipped with the Listeria monocytogenes gene mptC encoding the mannose-phosphotransferase system component IIC, the receptor for class IIa bacteriocins. Expression of mptC from the integration vector renders the naturally resistant L. lactis sensitive to class IIa bacteriocins. This sensitivity is then used to select the double crossover colonies on bacteriocin agar. Only the cells which have regained the endogenous bacteriocin resistance through the loss of the mptC plasmid will survive. The colonies carrying the desired deletion can then be distinguished from the wild-type revertants by PCR. By using the class IIa bacteriocins leucocin A, leucocin C or pediocin AcH as the counterselective agents, we deleted 22- and 33-kb chromosomal fragments from the wild-type nisin producing L. lactis strain N8. In conclusion, this counterselection method presented here is a convenient, efficient and inexpensive technique to generate successive deletions in L. lactis chromosome.

  5. Single-acquisition method for simultaneous determination of extrinsic gamma-camera sensitivity and spatial resolution

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J.A.M. [Servico de Fisica Medica, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)], E-mail: a.miranda@portugalmail.pt; Sarmento, S. [Servico de Fisica Medica, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Alves, P.; Torres, M.C. [Departamento de Fisica da Universidade do Porto, Rua do Campo Alegre 687, 4169-007 Porto (Portugal); Bastos, A.L. [Servico de Medicina Nuclear, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Ponte, F. [Servico de Fisica Medica, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)

    2008-01-15

    A new method for measuring simultaneously both the extrinsic sensitivity and spatial resolution of a gamma-camera in a single planar acquisition was implemented. A dual-purpose phantom (SR phantom; sensitivity/resolution) was developed, tested and the results compared with other conventional methods used for separate determination of these two important image quality parameters. The SR phantom yielded reproducible and accurate results, allowing an immediate visual inspection of the spatial resolution as well as the quantitative determination of the contrast for six different spatial frequencies. It also proved to be useful in the estimation of the modulation transfer function (MTF) of the image formation collimator/detector system at six different frequencies and can be used to estimate the spatial resolution as function of the direction relative to the digital matrix of the detector.

  6. Single-acquisition method for simultaneous determination of extrinsic gamma-camera sensitivity and spatial resolution

    International Nuclear Information System (INIS)

    Santos, J.A.M.; Sarmento, S.; Alves, P.; Torres, M.C.; Bastos, A.L.; Ponte, F.

    2008-01-01

    A new method for measuring simultaneously both the extrinsic sensitivity and spatial resolution of a gamma-camera in a single planar acquisition was implemented. A dual-purpose phantom (SR phantom; sensitivity/resolution) was developed, tested and the results compared with other conventional methods used for separate determination of these two important image quality parameters. The SR phantom yielded reproducible and accurate results, allowing an immediate visual inspection of the spatial resolution as well as the quantitative determination of the contrast for six different spatial frequencies. It also proved to be useful in the estimation of the modulation transfer function (MTF) of the image formation collimator/detector system at six different frequencies and can be used to estimate the spatial resolution as function of the direction relative to the digital matrix of the detector

  7. State of the art in non-animal approaches for skin sensitization testing: from individual test methods towards testing strategies.

    Science.gov (United States)

    Ezendam, Janine; Braakhuis, Hedwig M; Vandebriel, Rob J

    2016-12-01

    The hazard assessment of skin sensitizers relies mainly on animal testing, but much progress is made in the development, validation and regulatory acceptance and implementation of non-animal predictive approaches. In this review, we provide an update on the available computational tools and animal-free test methods for the prediction of skin sensitization hazard. These individual test methods address mostly one mechanistic step of the process of skin sensitization induction. The adverse outcome pathway (AOP) for skin sensitization describes the key events (KEs) that lead to skin sensitization. In our review, we have clustered the available test methods according to the KE they inform: the molecular initiating event (MIE/KE1)-protein binding, KE2-keratinocyte activation, KE3-dendritic cell activation and KE4-T cell activation and proliferation. In recent years, most progress has been made in the development and validation of in vitro assays that address KE2 and KE3. No standardized in vitro assays for T cell activation are available; thus, KE4 cannot be measured in vitro. Three non-animal test methods, addressing either the MIE, KE2 or KE3, are accepted as OECD test guidelines, and this has accelerated the development of integrated or defined approaches for testing and assessment (e.g. testing strategies). The majority of these approaches are mechanism-based, since they combine results from multiple test methods and/or computational tools that address different KEs of the AOP to estimate skin sensitization potential and sometimes potency. Other approaches are based on statistical tools. Until now, eleven different testing strategies have been published, the majority using the same individual information sources. Our review shows that some of the defined approaches to testing and assessment are able to accurately predict skin sensitization hazard, sometimes even more accurate than the currently used animal test. A few defined approaches are developed to provide an

  8. Nickel contact sensitivity in the guinea pig. An efficient open application test method

    DEFF Research Database (Denmark)

    Nielsen, G D; Rohold, A E; Andersen, Klaus Ejner

    1992-01-01

    Nickel contact sensitivity was successfully induced in guinea pigs using an open epicutaneous application method. Immediately after pretreatment with 1% aqueous sodium lauryl sulfate, upper back skin was treated daily for 4 weeks with 0.3%-3% nickel sulfate in either a 1% lanolin cream (Vaseline, p...

  9. Pyocin-sensitivity testing as a method of typing Pseudomonas aeruginosa: use of "phage-free" preparations of pyocin.

    Science.gov (United States)

    Rampling, A; Whitby, J L; Wildy, P

    1975-11-01

    A method for pyocin-sensitivity typing by means of "phage-free" preparations of pyocin is described. The method was tested on 227 isolates of P. aeruginosa, collected from 34 different foci of infection in hospitals in the British Isles and the results were compared with those for combined serological and phage typing of all strains and pyocin production of 105 of the isolates. It is concluded that pyocin-sensitivity typing is a simple and reliable method giving a high degree of discrimination, comparable to that of combined serological and phage typing, and it is suitable for use in routine hospital laboratories.

  10. Fast and Sensitive Method for Determination of Domoic Acid in Mussel Tissue

    Directory of Open Access Journals (Sweden)

    Elena Barbaro

    2016-01-01

    Full Text Available Domoic acid (DA, a neurotoxic amino acid produced by diatoms, is the main cause of amnesic shellfish poisoning (ASP. In this work, we propose a very simple and fast analytical method to determine DA in mussel tissue. The method consists of two consecutive extractions and requires no purification steps, due to a reduction of the extraction of the interfering species and the application of very sensitive and selective HILIC-MS/MS method. The procedural method was validated through the estimation of trueness, extract yield, precision, detection, and quantification limits of analytical method. The sample preparation was also evaluated through qualitative and quantitative evaluations of the matrix effect. These evaluations were conducted both on the DA-free matrix spiked with known DA concentration and on the reference certified material (RCM. We developed a very selective LC-MS/MS method with a very low value of method detection limit (9 ng g−1 without cleanup steps.

  11. A sensitive fluorescence quenching method for the detection of tartrazine with acriflavine in soft drinks.

    Science.gov (United States)

    Yang, Huan; Ran, Guihua; Yan, Jingjing; Zhang, Hui; Hu, Xiaoli

    2018-03-01

    In this work, a simple, rapid, sensitive, selective spectrofluorimetric method was applied to detect tartrazine. The fluorescence of acriflavine could be efficiently quenched by tartrazine. The method manifested real time response as well as presented satisfied linear relationship to tartrazine. The linear response range of tartrazine (R 2 = 0.9995) was from 0.056 to 5 μmol L -1 . The detection limit (3σ/k) was 0.017 μmol L -1 , indicating that this method could be applied to detect traces of tartrazine. The accuracy and precision of the method was further assured by recovery studies via a standard addition method, with percentage recoveries in the range of 96.0% to 103.0%. Moreover, a quenching mechanism was investigated systematically by the linear plots at varying temperatures based on the Stern-Volmer equation, fluorescence lifetime and UV-visible absorption spectra, all of which proved to be static quenching. This sensitive, selective assay possessed a great application prospect for the food industry owing to its simplicity and rapidity for the detection of tartrazine. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Boundary integral method to calculate the sensitivity temperature error of microstructured fibre plasmonic sensors

    International Nuclear Information System (INIS)

    Esmaeilzadeh, Hamid; Arzi, Ezatollah; Légaré, François; Hassani, Alireza

    2013-01-01

    In this paper, using the boundary integral method (BIM), we simulate the effect of temperature fluctuation on the sensitivity of microstructured optical fibre (MOF) surface plasmon resonance (SPR) sensors. The final results indicate that, as the temperature increases, the refractometry sensitivity of our sensor decreases from 1300 nm/RIU at 0 °C to 1200 nm/RIU at 50 °C, leading to ∼7.7% sensitivity reduction and the sensitivity temperature error of 0.15% °C −1 for this case. These results can be used for biosensing temperature-error adjustment in MOF SPR sensors, since biomaterials detection usually happens in this temperature range. Moreover, the signal-to-noise ratio (SNR) of our sensor decreases from 0.265 at 0 °C to 0.154 at 100 °C with the average reduction rate of ∼0.42% °C −1 . The results suggest that at lower temperatures the sensor has a higher SNR. (paper)

  13. A simple method to measure critical angles for high-sensitivity differential refractometry.

    Science.gov (United States)

    Zilio, S C

    2012-01-16

    A total internal reflection-based differencial refractometer, capable of measuring the real and imaginary parts of the complex refractive index in real time, is presented. The device takes advantage of the phase difference acquired by s- and p-polarized light to generate an easily detectable minimum at the reflected profile. The method allows to sensitively measuring transparent and turbid liquid samples.

  14. Differentiation of the insulin-sensitive glucose transporter in 3T3-L1 adipocytes

    International Nuclear Information System (INIS)

    Frost, S.C.; Baly, D.L.; Cushman, S.W.; Lane, M.D.; Simpson, I.A.

    1986-01-01

    3T3-L1 fibroblasts differentiate in culture to resemble adipocytes both morphologically and biochemically. Insulin-sensitive glucose transport, as measured by 2-deoxy-[1- 14 C]- glucose uptake in the undifferentiated cell is small (2X). In contrast, the rate of glucose transport in fully differentiated cells is elevated 15-fold over basal in the presence of insulin. To determine if this is due to an increase in the number of transporters/cell or accessibility to the transporters, the number of transporters was measured in subcellular fractions over differentiation using a 3 H-cytochalasin B binding assay. The increase in the rate of insulin-sensitive glucose transport directly parallels an increase in the number of transporters which reside in an insulin-responsive intracellular compartment. This observation was confirmed by identifying the transporters by immunoblotting using an antibody generated against the human erythrocyte transporter. The molecular weight of this transporter increases over differentiation from a single band of 40kDa to a heterogeneous triplet of 40, 44 and 48kDa. These data suggest that the transporter undergoes differential processing and that the functional, insulin-responsive transporter may be different from the insulin-insensitive (basal) transporter

  15. An approach of sensitivity and uncertainty analyses methods installation in a safety calculation

    International Nuclear Information System (INIS)

    Pepin, G.; Sallaberry, C.

    2003-01-01

    Simulation of the migration in deep geological formations leads to solve convection-diffusion equations in porous media, associated with the computation of hydrogeologic flow. Different time-scales (simulation during 1 million years), scales of space, contrasts of properties in the calculation domain, are taken into account. This document deals more particularly with uncertainties on the input data of the model. These uncertainties are taken into account in total analysis with the use of uncertainty and sensitivity analysis. ANDRA (French national agency for the management of radioactive wastes) carries out studies on the treatment of input data uncertainties and their propagation in the models of safety, in order to be able to quantify the influence of input data uncertainties of the models on the various indicators of safety selected. The step taken by ANDRA consists initially of 2 studies undertaken in parallel: - the first consists of an international review of the choices retained by ANDRA foreign counterparts to carry out their uncertainty and sensitivity analysis, - the second relates to a review of the various methods being able to be used in sensitivity and uncertainty analysis in the context of ANDRA's safety calculations. Then, these studies are supplemented by a comparison of the principal methods on a test case which gathers all the specific constraints (physical, numerical and data-processing) of the problem studied by ANDRA

  16. Determination of Some Cephalosporins in Pharmaceutical Formulations by a Simple and Sensitive Spectrofluorimetric Method

    Directory of Open Access Journals (Sweden)

    Ali Abdollahi, Ahad Bavili-Tabrizi

    2016-03-01

    Full Text Available Background: Cephalosporins are among the safest and the most effective broad-spectrum bactericidal antimicrobial agents which have been prescribed by the clinician as antibiotics. Thus, the developing of simple, sensitive and rapid analytical methods for their determination can be attractive and desirable. Methods: A simple, rapid and sensitive spectrofluorimetric method was developed for the determination of cefixime, cefalexin and ceftriaxone in pharmaceutical formulations. Proposed method is based on the oxidation of these cephalosporins with cerium (IV to produce cerium (III, and its fluorescence was monitored at 356 ± 3 nm after excitation at 254 ± 3 nm. Results: The variables effecting oxidation of each cephalosporin with cerum (IV were studied and optimized. Under the experimental conditions used, the calibration graphs were linear over the range 0.1-4 µg/mL. The limit of detection and limit of quantification were in the range 0.031-0.054 and 0.102-0.172 µg/mL, respectively. Intra- and inter-day assay precisions, expressed as the relative standard deviation (RSD, were lower than 5.6 and 6.8%, respectively. Conclusion: The proposed method was applied to the determination of studied cephalosporins in pharmaceutical formulations by good recoveries in the range 91-110%.

  17. A simple method for measuring glucose utilization of insulin-sensitive tissues by using the brain as a reference

    International Nuclear Information System (INIS)

    Namba, Hiroki; Nakagawa, Keiichi; Iyo, Masaomi; Fukushi, Kiyoshi; Irie, Toshiaki

    1994-01-01

    A simple method, without measurement of the plasma input function, to obtain semiquantitative values of glucose utilization in tissues other than the brain with radioactive deoxyglucose is reported. The brain, in which glucose utilization is essentially insensitive to plasma glucose and insulin concentrations, was used as an internal reference. The effects of graded doses of oral glucose loading (0.5, 1 and 2 mg/g body weight) on insulin-sensitive tissues (heart, muscle and fat tissue) were studied in the rat. By using the brain-reference method, dose-dependent increases in glucose utilization were clearly shown in all the insulin-sensitive tissues examined. The method seems to be of value for measurement of glucose utilization using radioactive deoxyglucose and positron emission tomography in the heart or other insulin-sensitive tissues, especially during glucose loading. (orig.)

  18. Measurement of radon in air by α track method enhancement detection sensitivity using a lamp

    International Nuclear Information System (INIS)

    Maki, Y.; Tanaka, F.

    1983-01-01

    A new α track method is proposed for the measurement of 222 Rn concentration in environmental levels. This involves collecting radon daughters on the surface of pilot lamp and detecting α-particles emitted from the nuclides ( 218 Po and 214 Po) by a detector (LR 115). The detection sensitivity of this method is 6 times greater than that of the conventional α track method. (author)

  19. Quantitative Evaluation of Aged AISI 316L Stainless Steel Sensitization to Intergranular Corrosion: Comparison Between Microstructural Electrochemical and Analytical Methods

    Science.gov (United States)

    Sidhom, H.; Amadou, T.; Sahlaoui, H.; Braham, C.

    2007-06-01

    The evaluation of the degree of sensitization (DOS) to intergranular corrosion (IGC) of a commercial AISI 316L austenitic stainless steel aged at temperatures ranging from 550 °C to 800 °C during 100 to 80,000 hours was carried out using three different assessment methods. (1) The microstructural method coupled with the Strauss standard test (ASTM A262). This method establishes the kinetics of the precipitation phenomenon under different aging conditions, by transmission electronic microscope (TEM) examination of thin foils and electron diffraction. The subsequent chromium-depleted zones are characterized by X-ray microanalysis using scanning transmission electronic microscope (STEM). The superimposition of microstructural time-temperature-precipitation (TTP) and ASTM A262 time-temperature-sensitization (TTS) diagrams provides the relationship between aged microstructure and IGC. Moreover, by considering the chromium-depleted zone characteristics, sensitization and desensitization criteria could be established. (2) The electrochemical method involving the double loop-electrochemical potentiokinetic reactivation (DL-EPR) test. The operating conditions of this test were initially optimized using the experimental design method on the bases of the reliability, the selectivity, and the reproducibility of test responses for both annealed and sensitized steels. The TTS diagram of the AISI 316L stainless steel was established using this method. This diagram offers a quantitative assessment of the DOS and a possibility to appreciate the time-temperature equivalence of the IGC sensitization and desensitization. (3) The analytical method based on the chromium diffusion models. Using the IGC sensitization and desensitization criteria established by the microstructural method, numerical solving of the chromium diffusion equations leads to a calculated AISI 316L TTS diagram. Comparison of these three methods gives a clear advantage to the nondestructive DL-EPR test when it is

  20. Doppler method leak detection for LMFBR steam generators. Pt. 3. Investigation of detection sensitivity and method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kinoshita, Izumi

    2001-01-01

    To prevent the expansion of tube damage and to maintain structural integrity in the steam generators (SGs) of a fast breeder reactor (FBR), it is necessary to detect precisely and immediately any leakage of water from heat transfer tubes. Therefore, the Doppler method was developed. Previous studies have revealed that, in the SG full-sector model that simulates actual SGs, the Doppler method can detect bubbles of 0.4 l/s within a few seconds. However in consideration of the dissolution rate of hydrogen generated by a sodium-water reaction even from a small water leak, it is necessary to detect smaller leakages of water from the heat transfer tubes. The detection sensitivity of the Doppler method and the influence of background noise were experimentally investigated. In-water experiments were performed using the SG model. The results show that the Doppler method can detect bubbles of 0.01 l/s (equivalent to a water leak rate of about 0.01 g/s) within a few seconds and that the background noise has little effect on water leak detection performance. The Doppler method thus has great potential for the detection of water leakage in SGs. (author)

  1. The use of graph theory in the sensitivity analysis of the model output: a second order screening method

    International Nuclear Information System (INIS)

    Campolongo, Francesca; Braddock, Roger

    1999-01-01

    Sensitivity analysis screening methods aim to isolate the most important factors in experiments involving a large number of significant factors and interactions. This paper extends the one-factor-at-a-time screening method proposed by Morris. The new method, in addition to the 'overall' sensitivity measures already provided by the traditional Morris method, offers estimates of the two-factor interaction effects. The number of model evaluations required is O(k 2 ), where k is the number of model input factors. The efficient sampling strategy in the parameter space is based on concepts of graph theory and on the solution of the 'handcuffed prisoner problem'

  2. On the sensitivity of FPPE - TWRC method in thermal effusivity investigations of solids

    International Nuclear Information System (INIS)

    Dadarlat, Dorin; Streza, Mihaela; Pop, Mircea N; Tosa, Valer

    2009-01-01

    The front detection configuration (FPPE) together with the thermal-wave-resonator-cavity (TWRC) method was used for direct measurement of the thermal effusivity of solid materials inserted as backings in the FPPE detection cell. It was demonstrated that the normalized phase of the FPPE signal has an oscillating dependence as a function of sample's thickness. The paper presents experimental results on solid materials, with various values of thermal effusivity (Cu, brass, steel, bakelite, wood). A study of the sensitivity of the technique for different liquid/backing effusivity ratios is performed. The highest sensitivity was obtained when investigating solids with values of thermal effusivity not far from the effusivity of the liquid layer of the detection cell.

  3. Sensitivity assessment of direct method for diagnosis of Trichomonas vaginalis in comparison with Dorset Culture media

    Directory of Open Access Journals (Sweden)

    ebrahim badparva

    2010-04-01

    Full Text Available Trichomonas vaginalis is a flagellate protozoan that lives in the genital tract and causes trichomoniasis in women. About 200 million people all over the world are infected with T. vaginalis. There are various methods with different sensitivity and specificity for detection of this parasite, that one of them is direct smear of vaginal secretions which is simpler, rapid and cheaper than other diagnostic methods. Materials and Methods: Demographic data was gathered by a questionnaire which contained different variables. Vaginal secretions samples were taken by spicolum and two swaps that maintained in glucose solution in separate tubes from 160 women referred to health centers of Khorramabad. One of the vaginal samples was examined by direct smear in saline solution and the other was cultured in Dorse medium. Results: Of 160 women suspected of trichomoniasis, 11.8% and 18.75% were positive by direct smear and culture respectively. The sensitivity of the direct method was 63.3%. Our findings indicated that 30% of the infected women belonged to the 31 – 35 age group, which had the most relative frequency of positive cases. Most of the patients (43% were illiterate or had elementary educational level. Conclussion: The sensivity of direct method is 63% in compare to culture ( as a Gold standard , which is ralatively low . Although the efficacy of this test could be imporved by shortening the elapsed time between sampling and examination , use of skilled microscopists , and different samples , but we recommend that more sensitive methods such as culture and PCR should be used .

  4. Sensitivity analysis and parameter estimation for distributed hydrological modeling: potential of variational methods

    Directory of Open Access Journals (Sweden)

    W. Castaings

    2009-04-01

    Full Text Available Variational methods are widely used for the analysis and control of computationally intensive spatially distributed systems. In particular, the adjoint state method enables a very efficient calculation of the derivatives of an objective function (response function to be analysed or cost function to be optimised with respect to model inputs.

    In this contribution, it is shown that the potential of variational methods for distributed catchment scale hydrology should be considered. A distributed flash flood model, coupling kinematic wave overland flow and Green Ampt infiltration, is applied to a small catchment of the Thoré basin and used as a relatively simple (synthetic observations but didactic application case.

    It is shown that forward and adjoint sensitivity analysis provide a local but extensive insight on the relation between the assigned model parameters and the simulated hydrological response. Spatially distributed parameter sensitivities can be obtained for a very modest calculation effort (~6 times the computing time of a single model run and the singular value decomposition (SVD of the Jacobian matrix provides an interesting perspective for the analysis of the rainfall-runoff relation.

    For the estimation of model parameters, adjoint-based derivatives were found exceedingly efficient in driving a bound-constrained quasi-Newton algorithm. The reference parameter set is retrieved independently from the optimization initial condition when the very common dimension reduction strategy (i.e. scalar multipliers is adopted.

    Furthermore, the sensitivity analysis results suggest that most of the variability in this high-dimensional parameter space can be captured with a few orthogonal directions. A parametrization based on the SVD leading singular vectors was found very promising but should be combined with another regularization strategy in order to prevent overfitting.

  5. Sensitive double-antibody method for simultaneous determination of insulin and growth hormone

    International Nuclear Information System (INIS)

    Koparanova, O.; Sotirov, G.; Tyrkolev, N.

    1982-01-01

    A method is described for simultaneous determination of insulin and growth hormone in one sample, using double-antibody technique. The method is characterized by appreciable sensitivity (2.5 μE/ml for insulin and a.2 ng/ml for growth hormone), exactness (variation quotient 6-16 per cent) and reproducibility (96.9-117 per cent). There was no statistically significant difference in the insulin and growth hormone values of the same sera, determined by the here suggested and the standard methods. The necessary test material for examination of either hormone is minimal (0.2 ml). One may thus extend the possibilities for radioimmunologic determination of insulin and growth hormone, when only minor amounts of serum or other biological fluid are available. The method is also less time consuming. Results are reported of statistical processing of an experimental model and different sera determined by the standard method and the one described by the authors. (author)

  6. A simple, rapid, cost-effective and sensitive method for detection of Salmonella in environmental and pecan samples.

    Science.gov (United States)

    Dobhal, S; Zhang, G; Rohla, C; Smith, M W; Ma, L M

    2014-10-01

    PCR is widely used in the routine detection of foodborne human pathogens; however, challenges remain in overcoming PCR inhibitors present in some sample matrices. The objective of this study was to develop a simple, sensitive, cost-effective and rapid method for processing large numbers of environmental and pecan samples for Salmonella detection. This study was also aimed at validation of a new protocol for the detection of Salmonella from in-shell pecans. Different DNA template preparation methods, including direct boiling, prespin, multiple washing and commercial DNA extraction kits, were evaluated with pure cultures of Salmonella Typhimurium and with enriched soil, cattle feces and in-shell pecan each spiked individually with Salmonella Typhimurium. PCR detection of Salmonella was conducted using invA and 16S rRNA gene (internal amplification control) specific primers. The effect of amplification facilitators, including bovine serum albumin (BSA), polyvinylpyrrolidone (PVP), polyethylene glycol (PEG) and gelatin on PCR sensitivity, was also evaluated. Conducting a prespin of sample matrices in combination with the addition of 0·4% (w/v) BSA and 1% (w/v) PVP in PCR mix was the simplest, most rapid, cost-effective and sensitive method for PCR detection of Salmonella, with up to 40 CFU Salmonella per reaction detectable in the presence of over 10(9 ) CFU ml(-1) of background micro-organisms from enriched feces soil or pecan samples. The developed method is rapid, cost-effective and sensitive for detection of Salmonella from different matrices. This study provides a method with broad applicability for PCR detection of Salmonella in complex sample matrices. This method has a potential for its application in different research arenas and diagnostic laboratories. © 2014 The Society for Applied Microbiology.

  7. A new surface resistance measurement method with ultrahigh sensitivity

    International Nuclear Information System (INIS)

    Liang, Changnian.

    1993-01-01

    A superconducting niobium triaxial cavity has been designed and fabricated to study residual surface resistance of planar superconducting materials. The edge of a 25.4 mm or larger diameter sample in the triaxial cavity is located outside the strong field region. Therefore, the edge effects and possible losses between the thin film and the substrate have been minimized, ensuring that induced RF losses are intrinsic to the test material. The fundamental resonant frequency of the cavity is the same as the working frequency of CEBAF cavities. The cavity has a compact size compared to its TE 011 counterpart, which makes it more sensitive to the sample's loss. For even higher sensitivity, a calorimetry method has been used to measure the RF losses on the superconducting sample. At 2 K, a 2 μK temperature change can be resolved by using carbon resistor sensors. The temperature distribution caused by RF heating is measured by 16 carbon composition resistor sensors. A 0.05 μW heating power can be detected as such a resolution, which translates to a surface resistance of 0.02 nΩ at a surface magnetic field of 52 Oe. This is the most sensitive device for surface resistance measurements to date. In addition, losses due to the indium seal, coupling probes, field emission sites other than the sample, and all of the high field resonator surface, are excluded in the measurement. Surface resistance of both niobium and high-Tc superconducting thin films has been measured. A low R s of 35.2 μΩ was measured for a 25.4 mm diameter YBa 2 Cu 3 O 7 thin film at 1.5 GHz and at 2 K. The measurement result is the first result for a large area epitaxially grown thin film sample at such a low RF frequency. The abrupt disappearance of multipacting between two parallel plates has been observed and monitored with the 16 temperature mapping sensors. Field emission or some field dependent anomalous RF losses on the niobium plate have also been observed

  8. A sensitivity analysis method for the body segment inertial parameters based on ground reaction and joint moment regressor matrices.

    Science.gov (United States)

    Futamure, Sumire; Bonnet, Vincent; Dumas, Raphael; Venture, Gentiane

    2017-11-07

    This paper presents a method allowing a simple and efficient sensitivity analysis of dynamics parameters of complex whole-body human model. The proposed method is based on the ground reaction and joint moment regressor matrices, developed initially in robotics system identification theory, and involved in the equations of motion of the human body. The regressor matrices are linear relatively to the segment inertial parameters allowing us to use simple sensitivity analysis methods. The sensitivity analysis method was applied over gait dynamics and kinematics data of nine subjects and with a 15 segments 3D model of the locomotor apparatus. According to the proposed sensitivity indices, 76 segments inertial parameters out the 150 of the mechanical model were considered as not influent for gait. The main findings were that the segment masses were influent and that, at the exception of the trunk, moment of inertia were not influent for the computation of the ground reaction forces and moments and the joint moments. The same method also shows numerically that at least 90% of the lower-limb joint moments during the stance phase can be estimated only from a force-plate and kinematics data without knowing any of the segment inertial parameters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A DNA microarray-based methylation-sensitive (MS)-AFLP hybridization method for genetic and epigenetic analyses.

    Science.gov (United States)

    Yamamoto, F; Yamamoto, M

    2004-07-01

    We previously developed a PCR-based DNA fingerprinting technique named the Methylation Sensitive (MS)-AFLP method, which permits comparative genome-wide scanning of methylation status with a manageable number of fingerprinting experiments. The technique uses the methylation sensitive restriction enzyme NotI in the context of the existing Amplified Fragment Length Polymorphism (AFLP) method. Here we report the successful conversion of this gel electrophoresis-based DNA fingerprinting technique into a DNA microarray hybridization technique (DNA Microarray MS-AFLP). By performing a total of 30 (15 x 2 reciprocal labeling) DNA Microarray MS-AFLP hybridization experiments on genomic DNA from two breast and three prostate cancer cell lines in all pairwise combinations, and Southern hybridization experiments using more than 100 different probes, we have demonstrated that the DNA Microarray MS-AFLP is a reliable method for genetic and epigenetic analyses. No statistically significant differences were observed in the number of differences between the breast-prostate hybridization experiments and the breast-breast or prostate-prostate comparisons.

  10. Effect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope.

    Science.gov (United States)

    Sader, John E; Lu, Jianing; Mulvaney, Paul

    2014-11-01

    Calibration of the optical lever sensitivities of atomic force microscope (AFM) cantilevers is especially important for determining the force in AFM measurements. These sensitivities depend critically on the cantilever mode used and are known to differ for static and dynamic measurements. Here, we calculate the ratio of the dynamic and static sensitivities for several common AFM cantilevers, whose shapes vary considerably, and experimentally verify these results. The dynamic-to-static optical lever sensitivity ratio is found to range from 1.09 to 1.41 for the cantilevers studied - in stark contrast to the constant value of 1.09 used widely in current calibration studies. This analysis shows that accuracy of the thermal noise method for the static spring constant is strongly dependent on cantilever geometry - neglect of these dynamic-to-static factors can induce errors exceeding 100%. We also discuss a simple experimental approach to non-invasively and simultaneously determine the dynamic and static spring constants and optical lever sensitivities of cantilevers of arbitrary shape, which is applicable to all AFM platforms that have the thermal noise method for spring constant calibration.

  11. Masonry fireplace emissions test method: Repeatability and sensitivity to fueling protocol.

    Science.gov (United States)

    Stern, C H; Jaasma, D R; Champion, M R

    1993-03-01

    A test method for masonry fireplaces has been evaluated during testing on six masonry fireplace configurations. The method determines carbon monoxide and particulate matter emission rates (g/h) and factors (g/kg) and does not require weighing of the appliance to determine the timing of fuel loading.The intralaboratory repeatability of the test method has been determined from multiple tests on the six fireplaces. For the tested fireplaces, the ratio of the highest to lowest measured PM rate averaged 1.17 and in no case was greater than 1.32. The data suggest that some of the variation is due to differences in fuel properties.The influence of fueling protocol on emissions has also been studied. A modified fueling protocol, tested in large and small fireplaces, reduced CO and PM emission factors by roughly 40% and reduced CO and PM rates from 0 to 30%. For both of these fireplaces, emission rates were less sensitive to fueling protocol than emission factors.

  12. Screening, sensitivity, and uncertainty for the CREAM method of Human Reliability Analysis

    International Nuclear Information System (INIS)

    Bedford, Tim; Bayley, Clare; Revie, Matthew

    2013-01-01

    This paper reports a sensitivity analysis of the Cognitive Reliability and Error Analysis Method for Human Reliability Analysis. We consider three different aspects: the difference between the outputs of the Basic and Extended methods, on the same HRA scenario; the variability in outputs through the choices made for common performance conditions (CPCs); and the variability in outputs through the assignment of choices for cognitive function failures (CFFs). We discuss the problem of interpreting categories when applying the method, compare its quantitative structure to that of first generation methods and discuss also how dependence is modelled with the approach. We show that the control mode intervals used in the Basic method are too narrow to be consistent with the Extended method. This motivates a new screening method that gives improved accuracy with respect to the Basic method, in the sense that (on average) halves the uncertainty associated with the Basic method. We make some observations on the design of a screening method that are generally applicable in Risk Analysis. Finally, we propose a new method of combining CPC weights with nominal probabilities so that the calculated probabilities are always in range (i.e. between 0 and 1), while satisfying sensible properties that are consistent with the overall CREAM method

  13. Methods and computer codes for probabilistic sensitivity and uncertainty analysis

    International Nuclear Information System (INIS)

    Vaurio, J.K.

    1985-01-01

    This paper describes the methods and applications experience with two computer codes that are now available from the National Energy Software Center at Argonne National Laboratory. The purpose of the SCREEN code is to identify a group of most important input variables of a code that has many (tens, hundreds) input variables with uncertainties, and do this without relying on judgment or exhaustive sensitivity studies. Purpose of the PROSA-2 code is to propagate uncertainties and calculate the distributions of interesting output variable(s) of a safety analysis code using response surface techniques, based on the same runs used for screening. Several applications are discussed, but the codes are generic, not tailored to any specific safety application code. They are compatible in terms of input/output requirements but also independent of each other, e.g., PROSA-2 can be used without first using SCREEN if a set of important input variables has first been selected by other methods. Also, although SCREEN can select cases to be run (by random sampling), a user can select cases by other methods if he so prefers, and still use the rest of SCREEN for identifying important input variables

  14. Two-dimensional electrophoretic analysis of transformation-sensitive polypeptides during chemically, spontaneously, and oncogene-induced transformation of rat liver epithelial cells

    DEFF Research Database (Denmark)

    Wirth, P J; Luo, L D; Fujimoto, Y

    1992-01-01

    ; AFB), spontaneously, and oncogene (v-Ha-ras, v-raf, and v-myc/v-raf)-induced transformation of RLE cells. Two-dimensional mapping of [35S]methionine-labeled whole cell lysate, cell-free in vitro translation products and [32P]orthophosphate-labeled polypeptides revealed subsets of polypeptides specific...... for each transformation modality. A search of the RLE protein database indicated the specific subcellular location for the majority of these transformation-sensitive proteins. Significant alterations in the expression of the extracellular matrix protein, fibronectin, as well as tropomyosin......- and intermediate filament-related polypeptides (vimentin, beta-tubulin, the cytokeratins, and actin) were observed among the various transformant cell lines. Immunoprecipitation and Western immunoblot analysis of tropomyosin expression in four individual AFB-, as well as four spontaneously induced, and each...

  15. Method of estimating the sensitivity of a calculated nuclide vector to deviations in initial data

    International Nuclear Information System (INIS)

    Ivanov, E.A.

    1998-12-01

    The application of perturbation theory algorithms in modelling of nuclides transmutation is considered. The perturbation theory is used to construct the analytical technique of sensitivity analysis. It is shown that such algorithms have to be used in modelling of lifetime performance of nuclear power installations with the Monte Carlo method. The present approach differs from others by consistent use of analytical methods. (author)

  16. A brief review of other notable protein blotting methods.

    Science.gov (United States)

    Kurien, Biji T; Scofield, R Hal

    2009-01-01

    A plethora of methods have been used for transferring proteins from the gel to the membrane. These include centrifuge blotting, electroblotting of proteins to Teflon tape and membranes for N- and C-terminal sequence analysis, multiple tissue blotting, a two-step transfer of low and high molecular weight proteins, blotting of Coomassie Brilliant Blue (CBB)-stained proteins from polyacrylamide gels to transparencies, acid electroblotting onto activated glass, membrane-array method for the detection of human intestinal bacteria in fecal samples, protein microarray using a new black cellulose nitrate support, electrotransfer using square wave alternating voltage for enhanced protein recovery, polyethylene glycol-mediated significant enhancement of the immunoblotting transfer, parallel protein chemical processing before and during western blot and the molecular scanner concept, electronic western blot of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry-identified polypeptides from parallel processed gel-separated proteins, semidry electroblotting of peptides and proteins from acid-urea polyacrylamide gels, transfer of silver-stained proteins from polyacrylamide gels to polyvinylidene difluoride (PVDF) membranes, and the display of K(+) channel proteins on a solid nitrocellulose support for assaying toxin binding. The quantification of proteins bound to PVDF membranes by elution of CBB, clarification of immunoblots on PVDF for transmission densitometry, gold coating of nonconductive membranes before MALDI tandem mass spectrometric analysis to prevent charging effect for analysis of peptides from PVDF membranes, and a simple method for coating native polysaccharides onto nitrocellulose are some of the methods involving either the manipulation of membranes with transferred proteins or just a passive transfer of antigens to membranes. All these methods are briefly reviewed in this chapter.

  17. Verification of intraspecimen method using constant stress tension test of sensitized alloy 600

    International Nuclear Information System (INIS)

    Lee, Seung Ki; Choi, Hoi Su; Hwang, Il Soon

    2005-01-01

    Stress corrosion cracking (SCC) occurring at the Nibase alloy 600 used in the nuclear power plant SG tubes and CRDM penetration nozzles had been reported after long-term operation in the harsh environment. Intraspecimen method was developed to predict the SCC initiation time statistically. [1] By dividing a test area into a number of smaller regions (intraspecimens) having homogeneous physical and chemical condition each SCC initiation in each intraspecimen could be counted as an independent outcome to provide enough number of statistical data. Earlier work of intraspecimen method had many problems in test method and didn't agree with Weibull statistics which is the theoretical base of intraspecimen method. The test method is improved in this intraspecimen test. To find out the root causes of the problems in earlier work and improve the accuracy of intraspecimen method, two kinds of materials are introduced, which are different in grain size but same in chemical composition. Ni-base alloy 600, heat no. J313 and J323 are used as test materials. Specimens of sensitized Alloy 600 are tested under the condition of constant tensile stress and well defined chemical environment therefore we can easily observe typical intergranular stress corrosion cracking (IGSCC). Material with finer grain (J323) showed the areadependence in agreement with theoretical prediction. But material with coarser grain (J313) did not show any significant area-dependence. While SCC initiates earlier at grain boundaries that are oriented close to normal to the stress axis, crack initiation time showed no correlation with grain boundary misorientation estimated by Electron Back Scattered Diffraction (EBSD). From the SCC initiation tests with two test materials, it is concluded that the number of grains in an intraspecimen, degree of sensitization and uniform stress distribution are important parameters to meet Weibull statistics

  18. A new method of removing the high value feedback resistor in the charge sensitive preamplifier

    International Nuclear Information System (INIS)

    Xi Deming

    1993-01-01

    A new method of removing the high value feedback resistor in the charge sensitive preamplifier is introduced. The circuit analysis of this novel design is described and the measured performances of a practical circuit are provided

  19. Kidney bean: a major sensitizer among legumes in asthma and rhinitis patients from India.

    Directory of Open Access Journals (Sweden)

    Ramkrashan Kasera

    Full Text Available BACKGROUND: The prevalence of IgE mediated food allergies has increased over the last two decades. Food allergy has been reported to be fatal in highly sensitive individuals. Legumes are important food allergens but their prevalence may vary among different populations. The present study identifies sensitization to common legumes among Indian population, characterizes allergens of kidney bean and establishes its cross reactivity with other legumes. METHODOLOGY: Patients (n = 355 with history of legume allergy were skin prick tested (SPT with 10 legumes. Specific IgE (sIgE and total IgE were estimated in sera by enzyme-linked immunosorbent assay. Characterization of kidney bean allergens and their cross reactivity was investigated by immunobiochemical methods. Identification of major allergens of kidney bean was carried out by mass spectrometry. PRINCIPAL FINDINGS: Kidney bean exhibited sensitization in 78 (22.0% patients followed by chickpea 65 (18.0% and peanut 53 (15%. SPT positive patients depicted significantly elevated sIgE levels against different legumes (r = 0.85, p<0.0001. Sera from 30 kidney bean sensitive individuals exhibited basophil histamine release (16-54% which significantly correlated with their SPT (r = 0.83, p<0.0001 and sIgE (r = 0.99, p<0.0001. Kidney bean showed eight major allergens of 58, 50, 45, 42, 40, 37, 34 and 18 kDa on immunoblot and required 67.3±2.51 ng of homologous protein for 50% IgE inhibition. Inhibition assays revealed extensive cross reactivity among kidney bean, peanut, black gram and pigeon pea. nLC-MS/MS analysis identified four allergens of kidney bean showing significant matches with known proteins namely lectin (phytohemagglutinin, phaseolin, alpha-amylase inhibitor precursor and group 3 late embryogenesis abundant protein. CONCLUSION/SIGNIFICANCE: Among legumes, kidney bean followed by chick pea and peanut are the major allergic triggers in asthma and rhinitis patients in India

  20. Leakage localisation method in a water distribution system based on sensitivity matrix: methodology and real test

    OpenAIRE

    Pascual Pañach, Josep

    2010-01-01

    Leaks are present in all water distribution systems. In this paper a method for leakage detection and localisation is presented. It uses pressure measurements and simulation models. Leakage localisation methodology is based on pressure sensitivity matrix. Sensitivity is normalised and binarised using a common threshold for all nodes, so a signatures matrix is obtained. A pressure sensor optimal distribution methodology is developed too, but it is not used in the real test. To validate this...

  1. Avoidance Behavior against Positive Allergens Detected with a Multiple Allergen Simultaneous Test Immunoblot Assay in Patients with Urticaria: Factors Associated with Avoidance Success/Failure.

    Science.gov (United States)

    Lee, Min Kyung; Kwon, In Ho; Kim, Han Su; Kim, Heung Yeol; Cho, Eun Byul; Bae, Youin; Park, Gyeong Hun; Park, Eun Joo; Kim, Kwang Ho; Kim, Kwang Joong

    2016-02-01

    Avoidance behavior against positive allergens detected by using multiple allergen simultaneous test (MAST)-immunoblot assay in patients with urticaria has been rarely reported. We aimed to assess the avoidance behavior of patients with urticaria against positive allergens detected with a MAST. One hundred and one urticaria patients who showed positivity to at least one allergen on a MAST completed a questionnaire regarding their test results. The avoidance behavior of the patients was evaluated, and relevant determining factors of avoidance success/failure were statistically assessed. We detected 144 different data (n=51, food allergens; n=17, pollen allergens; and n=76, aeroallergens) from 101 patients with urticaria. The avoidance failure rates were 33.3% for food allergens, 70.6% for pollen allergens, and 30.3% for aeroallergens. The pollen group showed a significantly higher avoidance failure rate than the food and aeroallergen groups (psuccessfully avoid allergens (psuccess or failure against allergens in patients with urticaria when clinicians conduct allergen-specific immunoglobulin E tests.

  2. Higher Levels of c-Met Expression and Phosphorylation Identify Cell Lines With Increased Sensitivity to AMG-458, a Novel Selective c-Met Inhibitor With Radiosensitizing Effects

    International Nuclear Information System (INIS)

    Li Bo; Torossian, Artour; Sun, Yunguang; Du, Ruihong; Dicker, Adam P.; Lu Bo

    2012-01-01

    Purpose: c-Met is overexpressed in some non-small cell lung cancer (NSCLC) cell lines and tissues. Cell lines with higher levels of c-Met expression and phosphorylation depend on this receptor for survival. We studied the effects of AMG-458 on 2 NSCLC cell lines. Methods and Materials: 3-(4,5-Dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl) -2H-tetrazolium assays assessed the sensitivities of the cells to AMG-458. Clonogenic survival assays illustrated the radiosensitizing effects of AMG-458. Western blot for cleaved caspase 3 measured apoptosis. Immunoblotting for c-Met, phospho-Met (p-Met), Akt/p-Akt, and Erk/p-Erk was performed to observe downstream signaling. Results: AMG-458 enhanced radiosensitivity in H441 but not in A549. H441 showed constitutive phosphorylation of c-Met. A549 expressed low levels of c-Met, which were phosphorylated only in the presence of exogenous hepatocyte growth factor. The combination of radiation therapy and AMG-458 treatment was found to synergistically increase apoptosis in the H441 cell line but not in A549. Radiation therapy, AMG-458, and combination treatment were found to reduce p-Akt and p-Erk levels in H441 but not in A549. H441 became less sensitive to AMG-458 after small interfering RNA knockdown of c-Met; there was no change in A549. After overexpression of c-Met, A549 became more sensitive, while H441 became less sensitive to AMG-458. Conclusions: AMG-458 was more effective in cells that expressed higher levels of c-Met/p-Met, suggesting that higher levels of c-Met and p-Met in NSCLC tissue may classify a subset of tumors that are more sensitive to molecular therapies against this receptor.

  3. A fast and highly sensitive blood culture PCR method for clinical detection of Salmonella enterica serovar Typhi

    Directory of Open Access Journals (Sweden)

    Zhou Liqing

    2010-04-01

    Full Text Available Abstract Background Salmonella Typhi causes an estimated 21 million new cases of typhoid fever and 216,000 deaths every year. Blood culture is currently the gold standard for diagnosis of typhoid fever, but it is time-consuming and takes several days for isolation and identification of causative organisms. It is then too late to initiate proper antibiotic therapy. Serological tests have very low sensitivity and specificity, and no practical value in endemic areas. As early diagnosis of the disease and prompt treatment are essential for optimal management, especially in children, a rapid sensitive detection method for typhoid fever is urgently needed. Although PCR is sensitive and rapid, initial research indicated similar sensitivity to blood culture and lower specificity. We developed a fast and highly sensitive blood culture PCR method for detection of Salmonella Typhi, allowing same-day initiation of treatment after accurate diagnosis of typhoid. Methods An ox bile tryptone soy broth was optimized for blood culture, which allows the complete lysis of blood cells to release intracellular bacteria without inhibiting the growth of Salmonella Typhi. Using the optimised broth Salmonella Typhi bacteria in artificial blood samples were enriched in blood culture and then detected by a PCR targeting the fliC-d gene of Salmonella Typhi. Results Tests demonstrated that 2.4% ox bile in blood culture not only lyzes blood cells completely within 1.5 hours so that the intracellular bacteria could be released, but also has no inhibiting effect on the growth of Salmonella Typhi. Three hour enrichment of Salmonella Typhi in tryptone soya broth containing 2.4% ox bile could increase the bacterial number from 0.75 CFU per millilitre of blood which is similar to clinical typhoid samples to the level which regular PCR can detect. The whole blood culture PCR assay takes less than 8 hours to complete rather than several days for conventional blood culture

  4. A combined HM-PCR/SNuPE method for high sensitive detection of rare DNA methylation

    Directory of Open Access Journals (Sweden)

    Tierling Sascha

    2010-06-01

    Full Text Available Abstract Background DNA methylation changes are widely used as early molecular markers in cancer detection. Sensitive detection and classification of rare methylation changes in DNA extracted from circulating body fluids or complex tissue samples is crucial for the understanding of tumor etiology, clinical diagnosis and treatment. In this paper, we describe a combined method to monitor the presence of methylated tumor DNA in an excess of unmethylated background DNA of non-tumorous cells. The method combines heavy methyl-PCR, which favors preferential amplification of methylated marker sequence from bisulfite-treated DNA with a methylation-specific single nucleotide primer extension monitored by ion-pair, reversed-phase, high-performance liquid chromatography separation. Results This combined method allows detection of 14 pg (that is, four to five genomic copies of methylated chromosomal DNA in a 2000-fold excess (that is, 50 ng of unmethylated chromosomal background, with an analytical sensitivity of > 90%. We outline a detailed protocol for the combined assay on two examples of known cancer markers (SEPT9 and TMEFF2 and discuss general aspects of assay design and data interpretation. Finally, we provide an application example for rapid testing on tumor methylation in plasma DNA derived from a small cohort of patients with colorectal cancer. Conclusion The method allows unambiguous detection of rare DNA methylation, for example in body fluid or DNA isolates from cells or tissues, with very high sensitivity and accuracy. The application combines standard technologies and can easily be adapted to any target region of interest. It does not require costly reagents and can be used for routine screening of many samples.

  5. Diagnostic sensitivity and specificity of a participatory disease surveillance method for highly pathogenic avian influenza in household chicken flocks in Indonesia.

    Science.gov (United States)

    Robyn, M; Priyono, W B; Kim, L M; Brum, E

    2012-06-01

    A study was conducted to assess the diagnostic sensitivity and specificity of a disease surveillance method for diagnosis of highly pathogenic avian influenza (HPAI) outbreaks in household chicken flocks used by participatory disease surveillance (PDS) teams in Yogyakarta Province, Indonesia. The Government of Indonesia, in partnership with the Food and Agriculture Organization of the United Nations, has implemented a PDS method for the detection of HPAI outbreaks in poultry since 2006. The PDS method in Indonesia utilizes both a clinical case definition (CD) and the result of a commercial rapid antigen test kit Yogyakarta 55611, to diagnose HPAI outbreaks, primarily in backyard chicken flocks. The following diagnostic sensitivities and specificities were obtained relative to real-time reverse transcription-PCR as the gold standard diagnostic test: 1) 89% sensitivity (CI95: 75%-97%) and 96% specificity (CI95: 89%-99%) for the PDS CD alone; 2) 86% sensitivity (CI95: 71%-95%) and 99% specificity (CI95: 94%-100%) for the rapid antigen test alone; and 3) 84% sensitivity (CI95: 68%-94%) and 100% specificity (CI95: 96%-100%) for the PDS CD result combined with the rapid antigen test result. Based on these results, HPAI outbreaks in extensively raised household chickens can be diagnosed with sufficient sensitivity and specificity using the PDS method as implemented in Indonesia. Subject to further field evaluation, data from this study suggest that the diagnostic sensitivity of the PDS method may be improved by expanding the PDS CD to include more possible clinical presentations of HPAI and by increasing the number of rapid antigen tests to three different birds with HPAI-compatible signs of same flock.

  6. Search for Allergens from the Pollen Proteome of Sunflower (Helianthus annuus L.): A Major Sensitizer for Respiratory Allergy Patients.

    Science.gov (United States)

    Ghosh, Nandini; Sircar, Gaurab; Saha, Bodhisattwa; Pandey, Naren; Gupta Bhattacharya, Swati

    2015-01-01

    Respiratory allergy triggered by pollen allergens is increasing at an alarming rate worldwide. Sunflower pollen is thought to be an important source of inhalant allergens. Present study aims to identify the prevalence of sunflower pollinosis among the Indian allergic population and characterizes the pollen allergens using immuno-proteomic tools. Clinico-immunological tests were performed to understand the prevalence of sensitivity towards sunflower pollen among the atopic population. Sera from selected sunflower positive patients were used as probe to detect the IgE-reactive proteins from the one and two dimensional electrophoretic separated proteome of sunflower pollen. The antigenic nature of the sugar moiety of the glycoallergens was studied by meta-periodate modification of IgE-immunoblot. Finally, these allergens were identified by mass-spectrometry. Prevalence of sunflower pollen sensitization was observed among 21% of the pollen allergic population and associated with elevated level of specific IgE and histamine in the sera of these patients. Immunoscreening of sunflower pollen proteome with patient sera detected seven IgE-reactive proteins with varying molecular weight and pI. Hierarchical clustering of 2D-immunoblot data highlighted three allergens characterized by a more frequent immuno-reactivity and increased levels of IgE antibodies in the sera of susceptible patients. These allergens were considered as the major allergens of sunflower pollen and were found to have their glycan moiety critical for inducing IgE response. Homology driven search of MS/MS data of these IgE-reactive proteins identified seven previously unreported allergens from sunflower pollen. Three major allergenic proteins were identified as two pectate lyases and a cysteine protease. Novelty of the present report is the identification of a panel of seven sunflower pollen allergens for the first time at immuno-biochemical and proteomic level, which substantiated the clinical evidence of

  7. PROMETHEE Method and Sensitivity Analysis in the Software Application for the Support of Decision-Making

    Directory of Open Access Journals (Sweden)

    Petr Moldrik

    2008-01-01

    Full Text Available PROMETHEE is one of methods, which fall into multi-criteria analysis (MCA. The MCA, as the name itself indicates, deals with the evaluation of particular variants according to several criteria. Developed software application (MCA8 for the support of multi-criteria decision-making was upgraded about PROMETHEE method and a graphic tool, which enables the execution of the sensitivity analysis. This analysis is used to ascertain how a given model output depends upon the input parameters. The MCA8 software application with mentioned graphic upgrade was developed for purposes of solving multi-criteria decision tasks. In the MCA8 is possible to perform sensitivity analysis by a simple form – through column graphs. We can change criteria significances (weights in these column graphs directly and watch the changes of the order of variants immediately.

  8. IGF-1 Prevents Diastolic and Systolic Dysfunction Associated with Cardiomyopathy and Preserves Adrenergic Sensitivity

    Science.gov (United States)

    Roof, Steve R.; Boslett, James; Russell, Duncan; del Rio, Carlos; Alecusan, Joe; Zweier, Jay L.; Ziolo, Mark T.; Hamlin, Robert; Mohler, Peter J.; Curran, Jerry

    2015-01-01

    Aims Insulin-like growth factor 1 (IGF-1)-dependent signaling promotes exercise-induced physiological cardiac hypertrophy. However, the in vivo therapeutic potential of IGF-1 for heart disease is not well established. Here we test the potential therapeutic benefits of IGF-1 on cardiac function using an in vivo model of chronic catecholamine-induced cardiomyopathy. Methods Rats were perfused with isoproterenol via osmotic pump (1 mg/kg/day) and treated with 2 mg/kg IGF-1 (2 mg/kg/day, 6 days a week) for 2 or 4 weeks. Echocardiography, ECG, and blood pressure were assessed. In vivo pressure-volume loop studies were conducted at 4 weeks. Heart sections were analyzed for fibrosis and apoptosis, and relevant biochemical signaling cascades were assessed. Results After 4 weeks, diastolic function (EDPVR, EDP, tau, E/A ratio), systolic function (PRSW, ESPVR, dP/dtmax), and structural remodeling (LV chamber diameter, wall thickness) were all adversely affected in isoproterenol-treated rats. All these detrimental effects were attenuated in rats treated with Iso+IGF-1. Isoproterenol-dependent effects on BP were attenuated by IGF-1 treatment. Adrenergic sensitivity was blunted in isoproterenol-treated rats but was preserved by IGF-1 treatment. Immunoblots indicate that cardioprotective p110α signaling and activated Akt are selectively upregulated in Iso+IGF-1 treated hearts. Expression of iNOS was significantly increased in both the Iso and Iso+IGF-1 groups, however tetrahydrobiopterin (BH4) levels were decreased in the Iso group and maintained by IGF-1 treatment. Conclusion IGF-1 treatment attenuates diastolic and systolic dysfunction associated with chronic catecholamine-induced cardiomyopathy while preserving adrenergic sensitivity and promoting BH4 production. These data support the potential use of IGF-1 therapy for clinical applications for cardiomyopathies. PMID:26399932

  9. Serological diagnosis of Besnoitia bennetti infection in donkeys (Equus asinus).

    Science.gov (United States)

    Ness, SallyAnne L; Schares, Gereon; Peters-Kennedy, Jeanine; Mittel, Linda D; Dubey, Jitender P; Bowman, Dwight D; Mohammed, Hussni O; Divers, Thomas J

    2014-11-01

    Besnoitiosis is an emerging infectious disease of donkeys (Equus asinus) in the United States for which there are currently no serologic methods of diagnosis. A study was performed to evaluate physical examination findings and 3 serologic assays for the detection of Besnoitia bennetti infection in donkeys. A prospective study of 416 donkeys from 6 privately owned herds across 5 U.S. states (New York, Pennsylvania, Vermont, Oregon, and Washington) was performed. Donkeys were examined for clinical lesions suggestive of besnoitiosis and evaluated for antibodies against B. bennetti using a fluorescent antibody test (FAT) and 2 immunoblot assays specific for bradyzoite and tachyzoite antigens, respectively. Donkeys were confirmed to be infected with B. bennetti by histology (cases; n = 32) and were compared to those with no clinical signs of besnoitiosis (controls; n = 384). Identifying clinical lesions in 2 or more locations correctly identified infected donkeys 83% of the time. Donkeys with besnoitiosis had significantly higher FAT titers (P donkeys. The sensitivity and specificity of the serologic assays for detecting besnoitiosis was 88% and 96% for FAT, 81% and 91% for bradyzoite immunoblot, and 91% and 92% for tachyzoite immunoblot, respectively. Fluorescent antibody and immunoblot assays are effective at identifying donkeys with besnoitiosis and provide a more efficient and less invasive diagnostic alternative to histology. © 2014 The Author(s).

  10. A rapid and sensitive method for measuring N-acetylglucosaminidase activity in cultured cells.

    Directory of Open Access Journals (Sweden)

    Victor Mauri

    Full Text Available A rapid and sensitive method to quantitatively assess N-acetylglucosaminidase (NAG activity in cultured cells is highly desirable for both basic research and clinical studies. NAG activity is deficient in cells from patients with Mucopolysaccharidosis type IIIB (MPS IIIB due to mutations in NAGLU, the gene that encodes NAG. Currently available techniques for measuring NAG activity in patient-derived cell lines include chromogenic and fluorogenic assays and provide a biochemical method for the diagnosis of MPS IIIB. However, standard protocols require large amounts of cells, cell disruption by sonication or freeze-thawing, and normalization to the cellular protein content, resulting in an error-prone procedure that is material- and time-consuming and that produces highly variable results. Here we report a new procedure for measuring NAG activity in cultured cells. This procedure is based on the use of the fluorogenic NAG substrate, 4-Methylumbelliferyl-2-acetamido-2-deoxy-alpha-D-glucopyranoside (MUG, in a one-step cell assay that does not require cell disruption or post-assay normalization and that employs a low number of cells in 96-well plate format. We show that the NAG one-step cell assay greatly discriminates between wild-type and MPS IIIB patient-derived fibroblasts, thus providing a rapid method for the detection of deficiencies in NAG activity. We also show that the assay is sensitive to changes in NAG activity due to increases in NAGLU expression achieved by either overexpressing the transcription factor EB (TFEB, a master regulator of lysosomal function, or by inducing TFEB activation chemically. Because of its small format, rapidity, sensitivity and reproducibility, the NAG one-step cell assay is suitable for multiple procedures, including the high-throughput screening of chemical libraries to identify modulators of NAG expression, folding and activity, and the investigation of candidate molecules and constructs for applications in

  11. Accuracy and Sensitivity of a Method of Jump Detection, Evaluated by Simulated Time Series

    Czech Academy of Sciences Publication Activity Database

    Chapanov, Y.; Ron, Cyril; Vondrák, Jan

    2017-01-01

    Roč. 14, č. 1 (2017), s. 73-82 ISSN 1214-9705 R&D Projects: GA ČR GA13-15943S Institutional support: RVO:67985815 Keywords : time series * data jump detection * high-sensitive method Subject RIV: DE - Earth Magnetism, Geodesy, Geography OBOR OECD: Physical geography Impact factor: 0.699, year: 2016

  12. A Fault Alarm and Diagnosis Method Based on Sensitive Parameters and Support Vector Machine

    Science.gov (United States)

    Zhang, Jinjie; Yao, Ziyun; Lv, Zhiquan; Zhu, Qunxiong; Xu, Fengtian; Jiang, Zhinong

    2015-08-01

    Study on the extraction of fault feature and the diagnostic technique of reciprocating compressor is one of the hot research topics in the field of reciprocating machinery fault diagnosis at present. A large number of feature extraction and classification methods have been widely applied in the related research, but the practical fault alarm and the accuracy of diagnosis have not been effectively improved. Developing feature extraction and classification methods to meet the requirements of typical fault alarm and automatic diagnosis in practical engineering is urgent task. The typical mechanical faults of reciprocating compressor are presented in the paper, and the existing data of online monitoring system is used to extract fault feature parameters within 15 types in total; the inner sensitive connection between faults and the feature parameters has been made clear by using the distance evaluation technique, also sensitive characteristic parameters of different faults have been obtained. On this basis, a method based on fault feature parameters and support vector machine (SVM) is developed, which will be applied to practical fault diagnosis. A better ability of early fault warning has been proved by the experiment and the practical fault cases. Automatic classification by using the SVM to the data of fault alarm has obtained better diagnostic accuracy.

  13. Efficient estimation of sensitivities for counterparty credit risk with the finite difference Monte Carlo method

    NARCIS (Netherlands)

    C.S.L. de Graaf (Kees); B.D. Kandhai; P.M.A. Sloot

    2017-01-01

    htmlabstractAccording to Basel III, financial institutions have to charge a credit valuation adjustment (CVA) to account for a possible counterparty default. Calculating this measure and its sensitivities is one of the biggest challenges in risk management. Here, we introduce an efficient method

  14. Ultra-sensitive chemiluminescence imaging DNA hybridization method in the detection of mosquito-borne viruses and parasites.

    Science.gov (United States)

    Zhang, Yingjie; Liu, Qiqi; Zhou, Biao; Wang, Xiaobo; Chen, Suhong; Wang, Shengqi

    2017-01-25

    Mosquito-borne viruses (MBVs) and parasites (MBPs) are transmitted through hematophagous arthropods-mosquitoes to homoiothermous vertebrates. This study aims at developing a detection method to monitor the spread of mosquito-borne diseases to new areas and diagnose the infections caused by MBVs and MBPs. In this assay, an ultra-sensitive chemiluminescence (CL) detection method was developed and used to simultaneously detect 19 common MBVs and MBPs. In vitro transcript RNA, virus-like particles (VLPs), and plasmids were established as positive or limit of detection (LOD) reference materials. MBVs and MBPs could be genotyped with high sensitivity and specificity. The cut-off values of probes were calculated. The absolute LODs of this strategy to detect serially diluted in vitro transcribed RNAs of MBVs and serially diluted plasmids of MBPs were 10 2 -10 3 copies/μl and 10 1 -10 2 copies/μl, respectively. Further, the LOD of detecting a strain of pre-quantified JEV was 10 1.8 -10 0.8 PFU/ml, fitted well in a linear regression model (coefficient of determination = 0.9678). Ultra-sensitive CL imaging DNA hybridization was developed and could simultaneously detect various MBVs and MBPs. The method described here has the potential to provide considerable labor savings due to its ability to screen for 19 mosquito-borne pathogens simultaneously.

  15. Sobol method application in dimensional sensitivity analyses of different AFM cantilevers for biological particles

    Science.gov (United States)

    Korayem, M. H.; Taheri, M.; Ghahnaviyeh, S. D.

    2015-08-01

    Due to the more delicate nature of biological micro/nanoparticles, it is necessary to compute the critical force of manipulation. The modeling and simulation of reactions and nanomanipulator dynamics in a precise manipulation process require an exact modeling of cantilevers stiffness, especially the stiffness of dagger cantilevers because the previous model is not useful for this investigation. The stiffness values for V-shaped cantilevers can be obtained through several methods. One of them is the PBA method. In another approach, the cantilever is divided into two sections: a triangular head section and two slanted rectangular beams. Then, deformations along different directions are computed and used to obtain the stiffness values in different directions. The stiffness formulations of dagger cantilever are needed for this sensitivity analyses so the formulations have been driven first and then sensitivity analyses has been started. In examining the stiffness of the dagger-shaped cantilever, the micro-beam has been divided into two triangular and rectangular sections and by computing the displacements along different directions and using the existing relations, the stiffness values for dagger cantilever have been obtained. In this paper, after investigating the stiffness of common types of cantilevers, Sobol sensitivity analyses of the effects of various geometric parameters on the stiffness of these types of cantilevers have been carried out. Also, the effects of different cantilevers on the dynamic behavior of nanoparticles have been studied and the dagger-shaped cantilever has been deemed more suitable for the manipulation of biological particles.

  16. Testing of the derivative method and Kruskal-Wallis technique for sensitivity analysis of SYVAC

    International Nuclear Information System (INIS)

    Prust, J.O.; Edwards, H.H.

    1985-04-01

    The Kruskal-Wallis method of one-way analysis of variance by ranks has proved successful in identifying input parameters which have an important influence on dose. This technique was extended to test for first order interactions between parameters. In view of a number of practical difficulties and the computing resources required to carry out a large number of runs, this test is not recommended for detecting interactions between parameters. The derivative method of sensitivity analysis examines the partial derivative values of each input parameter with dose at various points across the parameter range. Important input parameters are associated with high derivatives and the results agreed well with previous sensitivity studies. The derivative values also provided information on the data generation distributions to be used for the input parameters in order to concentrate sampling in the high dose region of the parameter space to improve the sampling efficiency. Furthermore, the derivative values provided information on parameter interactions, the feasibility of developing a high dose algorithm and formed the basis for developing a regression equation. (author)

  17. Radiation sensitive area detection device and method

    Science.gov (United States)

    Carter, Daniel C. (Inventor); Hecht, Diana L. (Inventor); Witherow, William K. (Inventor)

    1991-01-01

    A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

  18. Development of a Tandem Repeat-Based Polymerase Chain Displacement Reaction Method for Highly Sensitive Detection of 'Candidatus Liberibacter asiaticus'.

    Science.gov (United States)

    Lou, Binghai; Song, Yaqin; RoyChowdhury, Moytri; Deng, Chongling; Niu, Ying; Fan, Qijun; Tang, Yan; Zhou, Changyong

    2018-02-01

    Huanglongbing (HLB) is one of the most destructive diseases in citrus production worldwide. Early detection of HLB pathogens can facilitate timely removal of infected citrus trees in the field. However, low titer and uneven distribution of HLB pathogens in host plants make reliable detection challenging. Therefore, the development of effective detection methods with high sensitivity is imperative. This study reports the development of a novel method, tandem repeat-based polymerase chain displacement reaction (TR-PCDR), for the detection of 'Candidatus Liberibacter asiaticus', a widely distributed HLB-associated bacterium. A uniquely designed primer set (TR2-PCDR-F/TR2-PCDR-1R) and a thermostable Taq DNA polymerase mutant with strand displacement activity were used for TR-PCDR amplification. Performed in a regular thermal cycler, TR-PCDR could produce more than two amplicons after each amplification cycle. Sensitivity of the developed TR-PCDR was 10 copies of target DNA fragment. The sensitive level was proven to be 100× higher than conventional PCR and similar to real-time PCR. Data from the detection of 'Ca. L. asiaticus' with filed samples using the above three methods also showed similar results. No false-positive TR-PCDR amplification was observed from healthy citrus samples and water controls. These results thereby illustrated that the developed TR-PCDR method can be applied to the reliable, highly sensitive, and cost-effective detection of 'Ca. L. asiaticus'.

  19. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    Science.gov (United States)

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  20. Sensitivity improvement of an immuno-detection method for azaspiracids based on the use of microspheres coupled to a flow-fluorimetry system

    Directory of Open Access Journals (Sweden)

    María Fraga Corral

    2014-06-01

    These results demonstrate the high capability in terms of sensitivity of the microsphere-based immuno-detection assay for AZAs. The immobilization of AZA-1 instead of the synthetic AZA-2 used in Rodríguez et al (Rodriguez et al., 2014, combined with a lower mAb 8F4 concentration provided a remarkable improvement of sensitivity. The ON protocol used in Rodríguez et al. (Rodriguez et al., 2014 displayed a similar IC50 than the new short assay (around 1 nM while the new ON protocol provided an IC50 5-fold more sensitive (0.3 nM. Therefore, the new short assay allows a reduction of the experimental time. Additionally, the increase of sensitivity could help to avoid shellfish matrix interferences. Previously published works using immunoassays for the detection of phycotoxins present in shellfish avoided matrix interference by further extract dilution in combination with an increase of assay sensitivity (Fraga et al., 2012;Fraga et al., 2013. The extraction protocol described by Rodríguez et al. (Rodriguez et al., 2014 will probably be suitable for this newly optimized AZA-detection method since many reagents are the same and the higher sensitivity will allow higher extract dilution. Considering the extraction protocol recovery, sensitivity of the current assay and the regulated limit, shellfish extracts could be diluted up to 1:30 or 1:150 (v/v for detection with the short or long protocols, respectively. Additionally, mAb 8F4 was demonstrated to recognize AZA-2 and AZA-3 with cross-reactivities of 42 and 138 %, respectively. Presumably, this optimized assay will detect these analogs with similar cross-reactivity. The sensitivity of the microsphere-based assay for AZAs is enough to detect these compounds at the regulated levels in shellfish. This microsphere-based multi-detection method provides an easy-to-perform, highly sensitive and rapid method for the detection of AZAs. It could be included in a multi-detection method, which would allow time and sample volume

  1. Multisite-multivariable sensitivity analysis of distributed watershed models: enhancing the perceptions from computationally frugal methods

    Science.gov (United States)

    This paper assesses the impact of different likelihood functions in identifying sensitive parameters of the highly parameterized, spatially distributed Soil and Water Assessment Tool (SWAT) watershed model for multiple variables at multiple sites. The global one-factor-at-a-time (OAT) method of Morr...

  2. Efficient Estimation of Sensitivities for Counterparty Credit Risk with the Finite Difference Monte Carlo Method

    NARCIS (Netherlands)

    de Graaf, C.S.L.; Kandhai, D.; Sloot, P.M.A.

    According to Basel III, financial institutions have to charge a credit valuation adjustment (CVA) to account for a possible counterparty default. Calculating this measure and its sensitivities is one of the biggest challenges in risk management. Here, we introduce an efficient method for the

  3. Vector method for strain estimation in phase-sensitive optical coherence elastography

    Science.gov (United States)

    Matveyev, A. L.; Matveev, L. A.; Sovetsky, A. A.; Gelikonov, G. V.; Moiseev, A. A.; Zaitsev, V. Y.

    2018-06-01

    A noise-tolerant approach to strain estimation in phase-sensitive optical coherence elastography, robust to decorrelation distortions, is discussed. The method is based on evaluation of interframe phase-variation gradient, but its main feature is that the phase is singled out at the very last step of the gradient estimation. All intermediate steps operate with complex-valued optical coherence tomography (OCT) signals represented as vectors in the complex plane (hence, we call this approach the ‘vector’ method). In comparison with such a popular method as least-square fitting of the phase-difference slope over a selected region (even in the improved variant with amplitude weighting for suppressing small-amplitude noisy pixels), the vector approach demonstrates superior tolerance to both additive noise in the receiving system and speckle-decorrelation caused by tissue straining. Another advantage of the vector approach is that it obviates the usual necessity of error-prone phase unwrapping. Here, special attention is paid to modifications of the vector method that make it especially suitable for processing deformations with significant lateral inhomogeneity, which often occur in real situations. The method’s advantages are demonstrated using both simulated and real OCT scans obtained during reshaping of a collagenous tissue sample irradiated by an IR laser beam producing complex spatially inhomogeneous deformations.

  4. Radiation-sensitive material and method of recording information upon radiation-sensitive material

    International Nuclear Information System (INIS)

    Petrov, V.V.; Krjuchin, A.A.

    1981-01-01

    The invention can be employed for recording binary information in memory units of electronic computers, in video-recording equipment, laser recording devices and other recording means. The proposed radiation-sensitive material comprises a metallic layer made of silver, or copper, or nickel, or thallium, or alloy thereof, an inorganic material layer made of arsenic chalcogenide, or antimony chalcogenide, or bismuth chalcogenide, and a separation layer disposed between the metallic layer and the inorganic material layer made of a material which is inert relative to said layers, which separation layer has a thickness sufficient for preventing interaction between the metallic layer and the inorganic material layer when the radiation-sensitive materials is exposed to electromagnetic or corpuscular radiation having a power density lower than a threshold value required for the breakdown of the separation layer in the area exposed to radiation. The separation layer can be made from As, Sb, Si or Ge or their oxides, metallic oxides of e.g. Al, Ti, V or Fe, or from polyorganosiloxane films. (author)

  5. Sensitivity and Interaction Analysis Based on Sobol’ Method and Its Application in a Distributed Flood Forecasting Model

    Directory of Open Access Journals (Sweden)

    Hui Wan

    2015-06-01

    Full Text Available Sensitivity analysis is a fundamental approach to identify the most significant and sensitive parameters, helping us to understand complex hydrological models, particularly for time-consuming distributed flood forecasting models based on complicated theory with numerous parameters. Based on Sobol’ method, this study compared the sensitivity and interactions of distributed flood forecasting model parameters with and without accounting for correlation. Four objective functions: (1 Nash–Sutcliffe efficiency (ENS; (2 water balance coefficient (WB; (3 peak discharge efficiency (EP; and (4 time to peak efficiency (ETP were implemented to the Liuxihe model with hourly rainfall-runoff data collected in the Nanhua Creek catchment, Pearl River, China. Contrastive results for the sensitivity and interaction analysis were also illustrated among small, medium, and large flood magnitudes. Results demonstrated that the choice of objective functions had no effect on the sensitivity classification, while it had great influence on the sensitivity ranking for both uncorrelated and correlated cases. The Liuxihe model behaved and responded uniquely to various flood conditions. The results also indicated that the pairwise parameters interactions revealed a non-ignorable contribution to the model output variance. Parameters with high first or total order sensitivity indices presented a corresponding high second order sensitivity indices and correlation coefficients with other parameters. Without considering parameter correlations, the variance contributions of highly sensitive parameters might be underestimated and those of normally sensitive parameters might be overestimated. This research laid a basic foundation to improve the understanding of complex model behavior.

  6. Chemical kinetic functional sensitivity analysis: Elementary sensitivities

    International Nuclear Information System (INIS)

    Demiralp, M.; Rabitz, H.

    1981-01-01

    Sensitivity analysis is considered for kinetics problems defined in the space--time domain. This extends an earlier temporal Green's function method to handle calculations of elementary functional sensitivities deltau/sub i//deltaα/sub j/ where u/sub i/ is the ith species concentration and α/sub j/ is the jth system parameter. The system parameters include rate constants, diffusion coefficients, initial conditions, boundary conditions, or any other well-defined variables in the kinetic equations. These parameters are generally considered to be functions of position and/or time. Derivation of the governing equations for the sensitivities and the Green's funciton are presented. The physical interpretation of the Green's function and sensitivities is given along with a discussion of the relation of this work to earlier research

  7. Tetrathiomolybdate sensitizes ovarian cancer cells to anticancer drugs doxorubicin, fenretinide, 5-fluorouracil and mitomycin C

    International Nuclear Information System (INIS)

    Kim, Kyu Kwang; Lange, Thilo S; Singh, Rakesh K; Brard, Laurent; Moore, Richard G

    2012-01-01

    Our recent study showed that tetrathiomolybdate (TM), a drug to treat copper overload disorders, can sensitize drug-resistant endometrial cancer cells to reactive oxygen species (ROS)-generating anticancer drug doxorubicin. To expand these findings in the present study we explore TM efficacy in combination with a spectrum of ROS-generating anticancer drugs including mitomycin C, fenretinide, 5-fluorouracil and doxorubicin in ovarian cancer cells as a model system. The effects of TM alone or in combination with doxorubicin, mitomycin C, fenretinide, or 5-fluorouracil were evaluated using a sulforhodamine B assay. Flow cytometry was used to detect the induction of apoptosis and ROS generation. Immunoblot analysis was carried out to investigate changes in signaling pathways. TM potentiated doxorubicin-induced cytotoxicity and modulated key regulators of apoptosis (PARP, caspases, JNK and p38 MAPK) in SKOV-3 and A2780 ovarian cancer cell lines. These effects were linked to the increased production of ROS, as shown in SKOV-3 cells. ROS scavenging by ascorbic acid blocked the sensitization of cells by TM. TM also sensitized SKOV-3 to mitomycin C, fenretinide, and 5-fluorouracil. The increased cytotoxicity of these drugs in combination with TM was correlated with the activity of ROS, loss of a pro-survival factor (e.g. XIAP) and the appearance of a pro-apoptotic marker (e.g. PARP cleavage). Our data show that TM increases the efficacy of various anticancer drugs in ovarian cancer cells in a ROS-dependent manner

  8. Preliminary Structural Sensitivity Study of Hypersonic Inflatable Aerodynamic Decelerator Using Probabilistic Methods

    Science.gov (United States)

    Lyle, Karen H.

    2014-01-01

    Acceptance of new spacecraft structural architectures and concepts requires validated design methods to minimize the expense involved with technology validation via flighttesting. This paper explores the implementation of probabilistic methods in the sensitivity analysis of the structural response of a Hypersonic Inflatable Aerodynamic Decelerator (HIAD). HIAD architectures are attractive for spacecraft deceleration because they are lightweight, store compactly, and utilize the atmosphere to decelerate a spacecraft during re-entry. However, designers are hesitant to include these inflatable approaches for large payloads or spacecraft because of the lack of flight validation. In the example presented here, the structural parameters of an existing HIAD model have been varied to illustrate the design approach utilizing uncertainty-based methods. Surrogate models have been used to reduce computational expense several orders of magnitude. The suitability of the design is based on assessing variation in the resulting cone angle. The acceptable cone angle variation would rely on the aerodynamic requirements.

  9. Developing cultural sensitivity

    DEFF Research Database (Denmark)

    Ruddock, Heidi; Turner, deSalle

    2007-01-01

    . Background. Many countries are becoming culturally diverse, but healthcare systems and nursing education often remain mono-cultural and focused on the norms and needs of the majority culture. To meet the needs of all members of multicultural societies, nurses need to develop cultural sensitivity......Title. Developing cultural sensitivity: nursing students’ experiences of a study abroad programme Aim. This paper is a report of a study to explore whether having an international learning experience as part of a nursing education programme promoted cultural sensitivity in nursing students...... and incorporate this into caregiving. Method. A Gadamerian hermeneutic phenomenological approach was adopted. Data were collected in 2004 by using in-depth conversational interviews and analysed using the Turner method. Findings. Developing cultural sensitivity involves a complex interplay between becoming...

  10. Proteomic Analysis of Aphid-Resistant and -Sensitive Rose (Rosa Hybrida) Cultivars at Two Developmental Stages.

    Science.gov (United States)

    Muneer, Sowbiya; Jeong, Hai Kyoung; Park, Yoo Gyeong; Jeong, Byoung Ryong

    2018-05-25

    The rose is one the most commercially grown and costly ornamental plants because of its aesthetic beauty and aroma. A large number of pests attack its buds, flowers, leaves, and stem at every growing stage due to its high sugar content. The most common pest on roses are aphids which are considered to be the major cause for product loss. Aphid infestations lead to major changes in rose plants, such as large and irregular holes in petals, intact leaves and devouring tissues. It is hypothesized that different cut rose cultivars would have different levels of sensitivity or resistance to aphids, since different levels of infestation are observed in commercially cut rose production greenhouses. The present work compared four cut rose cultivars which were bred in Korea and were either resistant or sensitive to aphid infestation at different flower developmental stages. An integrative study was conducted using comprehensive proteome analyses. Proteins related to ubiquitin metabolism and the stress response were differentially expressed due to aphid infestation. The regulations and possible functions of identified proteins are presented in detail. The differential expressions of the identified proteins were validated by immunoblotting and blue native page. In addition, total sugar and carbohydrate content were also observed.

  11. LSHSIM: A Locality Sensitive Hashing based method for multiple-point geostatistics

    Science.gov (United States)

    Moura, Pedro; Laber, Eduardo; Lopes, Hélio; Mesejo, Daniel; Pavanelli, Lucas; Jardim, João; Thiesen, Francisco; Pujol, Gabriel

    2017-10-01

    Reservoir modeling is a very important task that permits the representation of a geological region of interest, so as to generate a considerable number of possible scenarios. Since its inception, many methodologies have been proposed and, in the last two decades, multiple-point geostatistics (MPS) has been the dominant one. This methodology is strongly based on the concept of training image (TI) and the use of its characteristics, which are called patterns. In this paper, we propose a new MPS method that combines the application of a technique called Locality Sensitive Hashing (LSH), which permits to accelerate the search for patterns similar to a target one, with a Run-Length Encoding (RLE) compression technique that speeds up the calculation of the Hamming similarity. Experiments with both categorical and continuous images show that LSHSIM is computationally efficient and produce good quality realizations. In particular, for categorical data, the results suggest that LSHSIM is faster than MS-CCSIM, one of the state-of-the-art methods.

  12. Preparation of colloidal gold for staining proteins electrotransferred onto nitrocellulose membranes.

    Science.gov (United States)

    Yamaguchi, K; Asakawa, H

    1988-07-01

    This paper describes a simple method of preparing colloidal gold for staining protein blots. Colloidal gold was prepared from 0.005 or 0.01% HAuCl4 by the addition of formalin as a reductant and potassium hydroxide. Staining of small cell carcinoma tissue extract blotted onto nitrocellulose membranes with this colloidal gold solution resulted in the appearance of a large number of clear wine-red bands. The sensitivity of gold staining was 60 times higher than that of Coomassie brilliant blue staining and almost comparable to that of silver staining of proteins in polyacrylamide gel. The sensitivity of this method was also satisfactory in comparison with that of enzyme immunoblotting. The colloidal gold prepared by this method is usable for routine work.

  13. Privacy Protection Method for Multiple Sensitive Attributes Based on Strong Rule

    Directory of Open Access Journals (Sweden)

    Tong Yi

    2015-01-01

    Full Text Available At present, most studies on data publishing only considered single sensitive attribute, and the works on multiple sensitive attributes are still few. And almost all the existing studies on multiple sensitive attributes had not taken the inherent relationship between sensitive attributes into account, so that adversary can use the background knowledge about this relationship to attack the privacy of users. This paper presents an attack model with the association rules between the sensitive attributes and, accordingly, presents a data publication for multiple sensitive attributes. Through proof and analysis, the new model can prevent adversary from using the background knowledge about association rules to attack privacy, and it is able to get high-quality released information. At last, this paper verifies the above conclusion with experiments.

  14. A Sensitivity Analysis Method to Study the Behavior of Complex Process-based Models

    Science.gov (United States)

    Brugnach, M.; Neilson, R.; Bolte, J.

    2001-12-01

    The use of process-based models as a tool for scientific inquiry is becoming increasingly relevant in ecosystem studies. Process-based models are artificial constructs that simulate the system by mechanistically mimicking the functioning of its component processes. Structurally, a process-based model can be characterized, in terms of its processes and the relationships established among them. Each process comprises a set of functional relationships among several model components (e.g., state variables, parameters and input data). While not encoded explicitly, the dynamics of the model emerge from this set of components and interactions organized in terms of processes. It is the task of the modeler to guarantee that the dynamics generated are appropriate and semantically equivalent to the phenomena being modeled. Despite the availability of techniques to characterize and understand model behavior, they do not suffice to completely and easily understand how a complex process-based model operates. For example, sensitivity analysis studies model behavior by determining the rate of change in model output as parameters or input data are varied. One of the problems with this approach is that it considers the model as a "black box", and it focuses on explaining model behavior by analyzing the relationship input-output. Since, these models have a high degree of non-linearity, understanding how the input affects an output can be an extremely difficult task. Operationally, the application of this technique may constitute a challenging task because complex process-based models are generally characterized by a large parameter space. In order to overcome some of these difficulties, we propose a method of sensitivity analysis to be applicable to complex process-based models. This method focuses sensitivity analysis at the process level, and it aims to determine how sensitive the model output is to variations in the processes. Once the processes that exert the major influence in

  15. [Sensitivity analysis of AnnAGNPS model's hydrology and water quality parameters based on the perturbation analysis method].

    Science.gov (United States)

    Xi, Qing; Li, Zhao-Fu; Luo, Chuan

    2014-05-01

    Sensitivity analysis of hydrology and water quality parameters has a great significance for integrated model's construction and application. Based on AnnAGNPS model's mechanism, terrain, hydrology and meteorology, field management, soil and other four major categories of 31 parameters were selected for the sensitivity analysis in Zhongtian river watershed which is a typical small watershed of hilly region in the Taihu Lake, and then used the perturbation method to evaluate the sensitivity of the parameters to the model's simulation results. The results showed that: in the 11 terrain parameters, LS was sensitive to all the model results, RMN, RS and RVC were generally sensitive and less sensitive to the output of sediment but insensitive to the remaining results. For hydrometeorological parameters, CN was more sensitive to runoff and sediment and relatively sensitive for the rest results. In field management, fertilizer and vegetation parameters, CCC, CRM and RR were less sensitive to sediment and particulate pollutants, the six fertilizer parameters (FR, FD, FID, FOD, FIP, FOP) were particularly sensitive for nitrogen and phosphorus nutrients. For soil parameters, K is quite sensitive to all the results except the runoff, the four parameters of the soil's nitrogen and phosphorus ratio (SONR, SINR, SOPR, SIPR) were less sensitive to the corresponding results. The simulation and verification results of runoff in Zhongtian watershed show a good accuracy with the deviation less than 10% during 2005- 2010. Research results have a direct reference value on AnnAGNPS model's parameter selection and calibration adjustment. The runoff simulation results of the study area also proved that the sensitivity analysis was practicable to the parameter's adjustment and showed the adaptability to the hydrology simulation in the Taihu Lake basin's hilly region and provide reference for the model's promotion in China.

  16. Protein and genetic diagnosis of limb girdle muscular dystrophy type 2A: The yield and the pitfalls.

    Science.gov (United States)

    Fanin, Marina; Angelini, Corrado

    2015-08-01

    Limb girdle muscular dystrophy type 2A (LGMD2A) is the most frequent form of LGMD worldwide. Comprehensive clinical assessment and laboratory testing is essential for diagnosis of LGMD2A. Muscle immunoblot analysis of calpain-3 is the most useful tool to direct genetic testing, as detection of calpain-3 deficiency has high diagnostic value. However, calpain-3 immunoblot testing lacks sensitivity in about 30% of cases due to gene mutations that inactivate the enzyme. The best diagnostic strategy should be determined on a case-by-case basis, depending on which tissues are available, and which molecular and/or genetic methods are adopted. In this work we survey the current knowledge, advantages, limitations, and pitfalls of protein testing and mutation detection in LGMD2A and provide an update of genetic epidemiology. © 2015 Wiley Periodicals, Inc.

  17. Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity.

    Science.gov (United States)

    Koefoed, Vilhelm F; Baste, Valborg; Roumes, Corinne; Høvding, Gunnar

    2015-03-01

    This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03). The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.

  18. A TOUCH-SENSITIVE DEVICE

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an optical touch-sensitive device and a method of determining a position and determining a position change of an object contacting an optical touch sensitive device. In particular, the present invention relates to an optical touch pad and a method of determining...... a position and determining a position change of an object contacting an optical touch pad. A touch-sensitive device, according to the present invention may comprise a light source, a touch- sensitive waveguide, a detector array, and a first light redirecting member, wherein at least a part of the light...... propagating towards a specific point of the detector array is prevented from being incident upon the specific point of the detector array when an object contacts a touch-sensitive surface of the touch-sensitive waveguide at a corresponding specific contact point....

  19. Sensitive method for the quantitative determination of bromocriptine in human plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Salvador, Arnaud; Dubreuil, Didier; Denouel, Jannick; Millerioux, L

    2005-06-25

    A sensitive LC-MS-MS assay for the quantitative determination of bromocriptine has been developed and validated and is described in this work. The assay involved the extraction of the analyte from 1 ml of human plasma using a solid phase extraction on Oasis MCX cartridges. Chromatography was performed on a Symmetry C18 (2.1 mm x 100 mm, 3.5 microm) column using a mobile phase consisting of 25:75:01 acetonitrile-water-formic acid with a flow rate of 250 microl/min. The linearity was within the concentration range of 2-500 pg/ml. The lower limit of quantification was 2 pg/ml. This method has been demonstrated to be an improvement over existing methods due to its greater sensitivity and specificity.

  20. A laboratory measurement method for pressure sensitive adhesives in agglomeration deinking of mixed office waste paper: The high-low scanning contrast method

    OpenAIRE

    Guolin Tong; Shuang Sun; Cuixia Wang; Kecheng Fu; Yungchang F. Chin

    2012-01-01

    A simple measurement method for pressure sensitive adhesives (PSA) in an agglomeration deinking system of mixed office waste paper was studied. This method was based on the different scanning performance of ink and PSA specks in hot-pressed and oven-dried handsheets with the change of contrast values that had been selected and set in the image analysis software. The numbers of ink specks per square meter (NPM) were well recognized at both low and high contrast values and exhibited a very good...

  1. Comparative Method for Indirect Sensitivity Measurement of UHF RFID Reader with Respect to Interoperability and Conformance Requirements

    Directory of Open Access Journals (Sweden)

    Lukas Kypus

    2014-01-01

    Full Text Available There is never-ending race for the competitive advantage that forces RFID technology service integrators to focus more on used technology qualitative aspects and theirs impacts inside RFID ecosystem. This paper contributes to UHF RFID reader qualitative parameters evaluation and assessment problematic. It presents and describes in details indirect method and procedure of sensitivity measurement created for UHF RFID readers. We applied this method on RFID readers within prepared test environment and confirmed long term intention and recognized trend. Due to regulations limitations, there is not possible to increase output power over defined limits, but there are possibilities to influence reader sensitivity. Our proposal is to use customized comparative measurement method with insertion loss compensation for return link. Beside the main goal achievement, results show as well the qualitative status of development snapshot of reader. Method and following experiment helped us to gain an external view, current values of important parameters and motivation we want to follow up on as well as compared developed reader with its commercial competitors.

  2. SuBSENSE: a universal change detection method with local adaptive sensitivity.

    Science.gov (United States)

    St-Charles, Pierre-Luc; Bilodeau, Guillaume-Alexandre; Bergevin, Robert

    2015-01-01

    Foreground/background segmentation via change detection in video sequences is often used as a stepping stone in high-level analytics and applications. Despite the wide variety of methods that have been proposed for this problem, none has been able to fully address the complex nature of dynamic scenes in real surveillance tasks. In this paper, we present a universal pixel-level segmentation method that relies on spatiotemporal binary features as well as color information to detect changes. This allows camouflaged foreground objects to be detected more easily while most illumination variations are ignored. Besides, instead of using manually set, frame-wide constants to dictate model sensitivity and adaptation speed, we use pixel-level feedback loops to dynamically adjust our method's internal parameters without user intervention. These adjustments are based on the continuous monitoring of model fidelity and local segmentation noise levels. This new approach enables us to outperform all 32 previously tested state-of-the-art methods on the 2012 and 2014 versions of the ChangeDetection.net dataset in terms of overall F-Measure. The use of local binary image descriptors for pixel-level modeling also facilitates high-speed parallel implementations: our own version, which used no low-level or architecture-specific instruction, reached real-time processing speed on a midlevel desktop CPU. A complete C++ implementation based on OpenCV is available online.

  3. Hamiltonian Markov Chain Monte Carlo Methods for the CUORE Neutrinoless Double Beta Decay Sensitivity

    Science.gov (United States)

    Graham, Eleanor; Cuore Collaboration

    2017-09-01

    The CUORE experiment is a large-scale bolometric detector seeking to observe the never-before-seen process of neutrinoless double beta decay. Predictions for CUORE's sensitivity to neutrinoless double beta decay allow for an understanding of the half-life ranges that the detector can probe, and also to evaluate the relative importance of different detector parameters. Currently, CUORE uses a Bayesian analysis based in BAT, which uses Metropolis-Hastings Markov Chain Monte Carlo, for its sensitivity studies. My work evaluates the viability and potential improvements of switching the Bayesian analysis to Hamiltonian Monte Carlo, realized through the program Stan and its Morpho interface. I demonstrate that the BAT study can be successfully recreated in Stan, and perform a detailed comparison between the results and computation times of the two methods.

  4. Correlation of radiation sensitivity and nitrofurantoin sensitivity of Escherichia coli K-12

    International Nuclear Information System (INIS)

    Kloeck, K.

    1981-01-01

    The Uvr- and rec-mutants of E.coli K-12 have been tested with a view to their radiation- and nitrofuration sensitivity. The tests showed that all mutants tested were more radiation- and NF-sensitive than the wild type AB 1157. When the NF-sensitivity had been compared to the UV- and X-ray sensitivity it became obvious that the NF-sensitivity is correlated to the UV-sensitivity. Studies carried out with regard to the time dependence of the NF-effect on E.coli showed that the effect of NF on E. Coli became weaker after about 1 1/2 to 2 hours. That is possibly caused by the fact that the E. coli bacteria succeed in reducing the NF to an inactive form. By means of nitrosoguanidine mutants of E-coli AB 1157 had been induced and by means of the Replicite Plating Method, NF-sensible mutants had been isolated from the plutonium mixture. Among the mutants which had been isolated by this method, 74% had been more UV-sensitive than the wild type and 55% more X-ray sensitive. Thus NF-sensitive mutants have not necessarily to be considered as rec-mutants as there are also uvr-mutants in the mixture. (orig.) [de

  5. Determining the sensitivity of Data Envelopment Analysis method used in airport benchmarking

    Directory of Open Access Journals (Sweden)

    Mircea BOSCOIANU

    2013-03-01

    Full Text Available In the last decade there were some important changes in the airport industry, caused by the liberalization of the air transportation market. Until recently airports were considered infrastructure elements, and they were evaluated only by traffic values or their maximum capacity. Gradual orientation towards commercial led to the need of finding another ways of evaluation, more efficiency oriented. The existing methods for assessing efficiency used for other production units were not suitable to be used in case of airports due to specific features and high complexity of airport operations. In the last years there were some papers that proposed the Data Envelopment Analysis as a method for assessing the operational efficiency in order to conduct the benchmarking. This method offers the possibility of dealing with a large number of variables of different types, which represents the main advantage of this method and also recommends it as a good benchmarking tool for the airports management. This paper goal is to determine the sensitivity of this method in relation with its inputs and outputs. A Data Envelopment Analysis is conducted for 128 airports worldwide, in both input- and output-oriented measures, and the results are analysed against some inputs and outputs variations. Possible weaknesses of using DEA for assessing airports performance are revealed and analysed against this method advantages.

  6. Sensitive enumeration of Listeria monocytogenes and other Listeria species in various naturally contaminated matrices using a membrane filtration method.

    Science.gov (United States)

    Barre, Léna; Brasseur, Emilie; Doux, Camille; Lombard, Bertrand; Besse, Nathalie Gnanou

    2015-06-01

    For the enumeration of Listeria monocytogenes (L. monocytogenes) in food, a sensitive enumeration method has been recently developed. This method is based on a membrane filtration of the food suspension followed by transfer of the filter on a selective medium to enumerate L. monocytogenes. An evaluation of this method was performed with several categories of foods naturally contaminated with L. monocytogenes. The results obtained with this technique were compared with those obtained from the modified reference EN ISO 11290-2 method for the enumeration of L. monocytogenes in food, and are found to provide more precise results. In most cases, the filtration method enabled to examine a greater quantity of food thus greatly improving the sensitivity of the enumeration. However, it was hardly applicable to some food categories because of filtration problems and background microbiota interference. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. [Influence of Sex and Age on Contrast Sensitivity Subject to the Applied Method].

    Science.gov (United States)

    Darius, Sabine; Bergmann, Lisa; Blaschke, Saskia; Böckelmann, Irina

    2018-02-01

    The aim of the study was to detect gender and age differences in both photopic and mesopic contrast sensitivity with different methods in relation to German driver's license regulations (Fahrerlaubnisverordnung; FeV). We examined 134 healthy volunteers (53 men, 81 women) with an age between 18 and 76 years, that had been divided into two groups (AG I Mars charts under standardized illumination were applied for photopic contrast sensitivity. We could not find any gender differences. When evaluating age, there were no differences between the two groups for the Mars charts nor in the Rodatest. In all other tests, the younger volunteers achieved significantly better results. For contrast vision, there exists age-adapted cut-off-values. Concerning the driving safety of traffic participants, sufficient photopic and mesopic contrast vision should be focused on, independent of age. Therefore, there is a need to reconsider the age-adapted cut-off-values. Georg Thieme Verlag KG Stuttgart · New York.

  8. Direct comparison of phase-sensitive vibrational sum frequency generation with maximum entropy method: case study of water.

    Science.gov (United States)

    de Beer, Alex G F; Samson, Jean-Sebastièn; Hua, Wei; Huang, Zishuai; Chen, Xiangke; Allen, Heather C; Roke, Sylvie

    2011-12-14

    We present a direct comparison of phase sensitive sum-frequency generation experiments with phase reconstruction obtained by the maximum entropy method. We show that both methods lead to the same complex spectrum. Furthermore, we discuss the strengths and weaknesses of each of these methods, analyzing possible sources of experimental and analytical errors. A simulation program for maximum entropy phase reconstruction is available at: http://lbp.epfl.ch/. © 2011 American Institute of Physics

  9. [The modified method registration of kinesthetic evoked potentials and its application for research of proprioceptive sensitivity disorders at spondylogenic cervical myelopathy].

    Science.gov (United States)

    Gordeev, S A; Voronin, S G

    2016-01-01

    To analyze the efficacy of modified (passive radiocarpal articulation flexion/extension) and «standard» (passive radiocarpal articulation flexion) methods of kinesthetic evoked potentials for proprioceptive sensitivity assessment in healthy subjects and patients with spondylotic cervical myelopathy. The study included 14 healthy subjects (4 women and 10 men, mean age 54.1±10.5 years) and 8 patients (2 women and 6 men, mean age 55.8±10.9 years) with spondylotic cervical myelopathy. Muscle-joint sensation was examined during the clinical study. A modified method of kinesthetic evoked potentials was developed. This method differed from the "standard" one by the organization of a cycle including several passive movements,where each new movement differed from the preceding one by the direction. The modified method of kinesthetic evoked potentials ensures more reliable kinesthetic sensitivity assessment due to movement variability. Asignificant increaseof the latent periods of the early components of the response was found in patients compared to healthy subjects. The modified method of kinesthetic evoked potentials can be used for objective diagnosis of proprioceptive sensitivity disorders in patients with spondylotic cervical myelopathy.

  10. A probabilistic method for species sensitivity distributions taking into account the inherent uncertainty and variability of effects to estimate environmental risk.

    Science.gov (United States)

    Gottschalk, Fadri; Nowack, Bernd

    2013-01-01

    This article presents a method of probabilistically computing species sensitivity distributions (SSD) that is well-suited to cope with distinct data scarcity and variability. First, a probability distribution that reflects the uncertainty and variability of sensitivity is modeled for each species considered. These single species sensitivity distributions are then combined to create an SSD for a particular ecosystem. A probabilistic estimation of the risk is carried out by combining the probability of critical environmental concentrations with the probability of organisms being impacted negatively by these concentrations. To evaluate the performance of the method, we developed SSD and risk calculations for the aquatic environment exposed to triclosan. The case studies showed that the probabilistic results reflect the empirical information well, and the method provides a valuable alternative or supplement to more traditional methods for calculating SSDs based on averaging raw data and/or on using theoretical distributional forms. A comparison and evaluation with single SSD values (5th-percentile [HC5]) revealed the robustness of the proposed method. Copyright © 2012 SETAC.

  11. Method of shaping of direction-characterization of sensitivity of ionizing radiation detection probe

    International Nuclear Information System (INIS)

    Czarnecki, J.; Jaszczuk, J.; Kruczyk, M.; Slapa, M.; Wroblewski, T.

    1986-01-01

    A method of shaping of direction-characterization of sensitivity of the ionizing radiation detection probe, especially equipped with small gamma detectors is described. Two detectors are placed coaxially in the bases of the cylindrical shield. One of them is uncovered in the highest degree and the second is not covered to a maximum. The signals from them are processed on the standarized sequences of electrical impulses (taking into account the heights and the widths of the amplitude). 2 figs., 1 tab. (A.S.)

  12. Development of a new, rapid and sensitive HPTLC method for estimation of Milnacipran in bulk, formulation and compatibility study

    Directory of Open Access Journals (Sweden)

    Gautam Singhvi

    2017-05-01

    Full Text Available A simple, sensitive and rapid high performance thin layer chromatographic (HPTLC method has been developed and validated for quantitative determination of Milnacipran Hydrochloride (MIL in bulk and formulations. The chromatographic development was carried out on HPTLC plates precoated with silica gel 60 F254 using a mixture of acetonitrile, water and ammonia (6:0.6:1.6 (v/v/v as mobile phase. Detection was carried out densitometrically at 220 nm. The Rf value of drug was found to be 0.63 ± 0.02. The method was validated as per ICH guideline with respect to linearity, accuracy, precision, robustness etc. The calibration curve was found to be linear over a range of 100–1000 ng μL−1 with a regression coefficient of 0.999. The accuracy was found to be very high (99.12–100.87%. %RSD values for intra-day and inter-day variation were not more than 1.43. The method has demonstrated high sensitivity and specificity. The method was applied for compatibility studies also. The method is new, simple and economic for routine estimation of MIL in bulk, preformulation studies and pharmaceutical formulation to help the industries as well as researchers for their sensitive determination of MIL rapidly at low cost in routine analysis.

  13. [Improvement of sensitivity in the second generation HCV core antigen assay by a novel concentration method using polyethylene glycol (PEG)].

    Science.gov (United States)

    Higashimoto, Makiko; Takahashi, Masahiko; Jokyu, Ritsuko; Syundou, Hiromi; Saito, Hidetsugu

    2007-11-01

    A HCV core antigen (Ag) detection assay system, Lumipulse Ortho HCV Ag has been developed and is commercially available in Japan with a lower detection level limit of 50 fmol/l, which is equivalent to 20 KIU/ml in PCR quantitative assay. HCV core Ag assay has an advantage of broader dynamic range compared with PCR assay, however the sensitivity is lower than PCR. We developed a novel HCV core Ag concentration method using polyethylene glycol (PEG), which can improve the sensitivity five times better than the original assay. The reproducibility was examined by consecutive five-time measurement of HCV patients serum, in which the results of HCV core Ag original and concentrated method were 56.8 +/- 8.1 fmol/l (mean +/- SD), CV 14.2% and 322.9 +/- 45.5 fmol/l CV 14.0%, respectively. The assay results of HCV negative samples in original HCV core Ag were all 0.1 fmol/l and the results were same even in the concentration method. The results of concentration method were 5.7 times higher than original assay, which was almost equal to theoretical rate as expected. The assay results of serially diluted samples were also as same as expected data in both original and concentration assay. We confirmed that the sensitivity of HCV core Ag concentration method had almost as same sensitivity as PCR high range assay in the competitive assay study using the serially monitored samples of five HCV patients during interferon therapy. A novel concentration method using PEG in HCV core Ag assay system seems to be useful for assessing and monitoring interferon treatment for HCV.

  14. Prediction of clamp-derived insulin sensitivity from the oral glucose insulin sensitivity index

    DEFF Research Database (Denmark)

    Tura, Andrea; Chemello, Gaetano; Szendroedi, Julia

    2018-01-01

    that underwent both a clamp and an OGTT or meal test, thereby allowing calculation of both the M value and OGIS. The population was divided into a training and a validation cohort (n = 359 and n = 154, respectively). After a stepwise selection approach, the best model for M value prediction was applied......AIMS/HYPOTHESIS: The euglycaemic-hyperinsulinaemic clamp is the gold-standard method for measuring insulin sensitivity, but is less suitable for large clinical trials. Thus, several indices have been developed for evaluating insulin sensitivity from the oral glucose tolerance test (OGTT). However......, most of them yield values different from those obtained by the clamp method. The aim of this study was to develop a new index to predict clamp-derived insulin sensitivity (M value) from the OGTT-derived oral glucose insulin sensitivity index (OGIS). METHODS: We analysed datasets of people...

  15. Variation of strain rate sensitivity index of a superplastic aluminum alloy in different testing methods

    Science.gov (United States)

    Majidi, Omid; Jahazi, Mohammad; Bombardier, Nicolas; Samuel, Ehab

    2017-10-01

    The strain rate sensitivity index, m-value, is being applied as a common tool to evaluate the impact of the strain rate on the viscoplastic behaviour of materials. The m-value, as a constant number, has been frequently taken into consideration for modeling material behaviour in the numerical simulation of superplastic forming processes. However, the impact of the testing variables on the measured m-values has not been investigated comprehensively. In this study, the m-value for a superplastic grade of an aluminum alloy (i.e., AA5083) has been investigated. The conditions and the parameters that influence the strain rate sensitivity for the material are compared with three different testing methods, i.e., monotonic uniaxial tension test, strain rate jump test and stress relaxation test. All tests were conducted at elevated temperature (470°C) and at strain rates up to 0.1 s-1. The results show that the m-value is not constant and is highly dependent on the applied strain rate, strain level and testing method.

  16. Sensitivity study with respect to direction of ADI method during re-flooding in AHWR

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, M.; Mukhopadhyay, D. [Bhabha Atomic Research Centre, Mumbai (India). Reactor Safety Div.; Ghosh, A.K. [Bhabha Atomic Research Centre, Mumbai (India). Raja Ramanna Fellow; Kumar, R. [Indian Institute of Technology, Roorkee (India)

    2015-05-15

    The Advanced Heavy water Reactor (AHWR) is a natural circulation vertical pressure tube type boiling light water cooled and heavy water moderated reactor. As the AHWR fuel bundle quenching under accident condition is designed primarily with radial jets at several axial locations, bottom re-flooding still remain open as another option. Radial direction injection of emergency core cooling leads to rewetting of AHWR fuel cluster in circumferential direction. A 3D fuel pin model has been developed by using Finite Difference Method (FDM) of transient heat conduction equation. Alternating Direction Implicit technique of Finite Difference Method (FDM) has been used for discretisation of numerical equation in different time step at different direction. Sensitivity numerical study with respect to direction of ADI method has been carried out to optimize the time step during the transient as well as steady state and is found that it is insensitivity with direction of solution. Further, to assess influence of circumferential rewetting vis-a-vis axial rewetting. Both the analyses are carried out with same fluid temperature and heat transfer coefficients as boundary conditions. It has been found from the analyses that for radial jet, the circumferential conduction is significant and overall the fuel temperature falls in the quench plane with the initiation of quenching event. The paper discusses the sensitivity study with respect to direction of ADI solution and comparison of numerical results for circumferential and axial rewetting for single pin.

  17. Risk Assessment Method for Offshore Structure Based on Global Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    Zou Tao

    2012-01-01

    Full Text Available Based on global sensitivity analysis (GSA, this paper proposes a new risk assessment method for an offshore structure design. This method quantifies all the significances among random variables and their parameters at first. And by comparing the degree of importance, all minor factors would be negligible. Then, the global uncertainty analysis work would be simplified. Global uncertainty analysis (GUA is an effective way to study the complexity and randomness of natural events. Since field measured data and statistical results often have inevitable errors and uncertainties which lead to inaccurate prediction and analysis, the risk in the design stage of offshore structures caused by uncertainties in environmental loads, sea level, and marine corrosion must be taken into account. In this paper, the multivariate compound extreme value distribution model (MCEVD is applied to predict the extreme sea state of wave, current, and wind. The maximum structural stress and deformation of a Jacket platform are analyzed and compared with different design standards. The calculation result sufficiently demonstrates the new risk assessment method’s rationality and security.

  18. Fast and sensitive method for detecting volatile species in liquids

    Science.gov (United States)

    Trimarco, Daniel B.; Pedersen, Thomas; Hansen, Ole; Chorkendorff, Ib; Vesborg, Peter C. K.

    2015-07-01

    This paper presents a novel apparatus for extracting volatile species from liquids using a "sniffer-chip." By ultrafast transfer of the volatile species through a perforated and hydrophobic membrane into an inert carrier gas stream, the sniffer-chip is able to transport the species directly to a mass spectrometer through a narrow capillary without the use of differential pumping. This method inherits features from differential electrochemical mass spectrometry (DEMS) and membrane inlet mass spectrometry (MIMS), but brings the best of both worlds, i.e., the fast time-response of a DEMS system and the high sensitivity of a MIMS system. In this paper, the concept of the sniffer-chip is thoroughly explained and it is shown how it can be used to quantify hydrogen and oxygen evolution on a polycrystalline platinum thin film in situ at absolute faradaic currents down to ˜30 nA. To benchmark the capabilities of this method, a CO-stripping experiment is performed on a polycrystalline platinum thin film, illustrating how the sniffer-chip system is capable of making a quantitative in situ measurement of <1 % of a monolayer of surface adsorbed CO being electrochemically stripped off an electrode at a potential scan-rate of 50 mV s-1.

  19. High Temperature and High Sensitive NOx Gas Sensor with Hetero-Junction Structure using Laser Ablation Method

    Science.gov (United States)

    Gao, Wei; Shi, Liqin; Hasegawa, Yuki; Katsube, Teruaki

    In order to develop a high temperature (200°C˜400°C) and high sensitive NOx gas sensor, we developed a new structure of SiC-based hetero-junction device Pt/SnO2/SiC/Ni, Pt/In2O3/SiC/Ni and Pt/WO3/SiC/Ni using a laser ablation method for the preparation of both metal (Pt) electrode and metal-oxide film. It was found that Pt/In2O3/SiC/Ni sensor shows higher sensitivity to NO2 gas compared with the Pt/SnO2/SiC/Ni and Pt/WO3/SiC/Ni sensor, whereas the Pt/WO3/SiC/Ni sensor had better sensitivity to NO gas. These results suggest that selective detection of NO and NO2 gases may be obtained by choosing different metal oxide films.

  20. Progress in the development of phase-sensitive neutron reflectometry methods

    International Nuclear Information System (INIS)

    Majkrzak, C.F.; Berk, N.F.; Kienzle, P.; Perez-Salas, U.

    2009-01-01

    It has been a number of years since phase-sensitive specular neutron reflectometry (PSNR) methods employing reference layers were first introduced to help remove the ambiguity inherent in the reconstruction of scattering length density (SLD) depth profiles (Majkrzak, C. F.; Berk, N. F. Physica B 2003, 336, 27) from specular reflectivity measurements. Although a number of scientific applications of PSNR techniques have now been successfully realized (Majkrzak, C. F.; Berk, N. F.; Perez-Salas, U. A. Langmuir 2003, 19, 7796 and references therein), in certain cases practical difficulties remain. In this article, we describe possible solutions to two specific problems: (1) the need for explicit, detailed knowledge of the SLD profile of a given reference layer of finite thickness; and (2) for a reference layer of finite thickness in which only two density variations are possible, how to identify which of two mathematical solutions corresponds to the true physical structure.

  1. Progress in the development of phase-sensitive neutron reflectometry methods.

    Energy Technology Data Exchange (ETDEWEB)

    Majkrzak, C. F.; Berk, N. F.; Kienzle, P.; Perez-Salas, U. (Materials Science Division); (NIST Center for Neutron Research)

    2009-01-01

    It has been a number of years since phase-sensitive specular neutron reflectometry (PSNR) methods employing reference layers were first introduced to help remove the ambiguity inherent in the reconstruction of scattering length density (SLD) depth profiles (Majkrzak, C. F.; Berk, N. F. Physica B 2003, 336, 27) from specular reflectivity measurements. Although a number of scientific applications of PSNR techniques have now been successfully realized (Majkrzak, C. F.; Berk, N. F.; Perez-Salas, U. A. Langmuir 2003, 19, 7796 and references therein), in certain cases practical difficulties remain. In this article, we describe possible solutions to two specific problems: (1) the need for explicit, detailed knowledge of the SLD profile of a given reference layer of finite thickness; and (2) for a reference layer of finite thickness in which only two density variations are possible, how to identify which of two mathematical solutions corresponds to the true physical structure.

  2. Sensitive method for the analysis of carbohydrates by gas chromatography of 3H-labeled alditol acetates

    International Nuclear Information System (INIS)

    Prehm, P.; Scheid, A.

    1978-01-01

    A highly sensitive method has been developed for the analysis of carbohydrates from glycoproteins or lipopolysaccharides. The method is based on labeling the carbohydrates with [ 3 H] sodium borohydride, acetylating the resulting alditols and separating them by gas chromatography. The gas effluent is fractionated by trapping on silicone-coated glass beads and the amount of radioactivity is determined. This permits the quantitation of as little as 0.2 nmoles monosaccharide with an accuracy of 10 to 15%. (Auth)

  3. A simple and sensitive method for the determination of fibric acids in the liver by liquid chromatography.

    Science.gov (United States)

    Karahashi, Minako; Fukuhara, Hiroto; Hoshina, Miki; Sakamoto, Takeshi; Yamazaki, Tohru; Mitsumoto, Atsushi; Kawashima, Yoichi; Kudo, Naomi

    2014-01-01

    Fibrates are used in biochemical and pharmacological studies as bioactive tools. Nevertheless, most studies have lacked information concerning the concentrations of fibric acids working inside tissues because a simple and sensitive method is not available for their quantitation. This study aimed to develop a simple and sensitive bioanalytical method for the quantitation of clofibric, bezafibric and fenofibric acids in samples of very small portions of tissues. Fibric acids were extracted into n-hexane-ethyl acetate from tissue homogenates (10 mg of liver, kidney or muscle) or serum (100 µL) and were derivatized with 4-bromomethyl-6,7-dimethoxycoumarin, followed by HPLC with fluorescence detection. These compounds were separated isocratically on a reversed phase with acetonitrile-water. Standard analytical curves were linear over the concentration range of 0.2-20 nmol/10 mg of liver. Precision and accuracy were within acceptable limits. Recovery from liver homogenates ranged from 93.03 to 112.29%. This method enabled the quantitation of fibric acids in 10 mg of liver from rats treated with clofibric acid, bezafibric acid or fenofibrate. From these analytical data, it became clear that there was no large difference in ratio of acyl-CoA oxidase 1 (Acox1) mRNA level to fibric acid content in the liver among the three fibric acids, suggesting that these three fibric acids have similar potency to increase expression of the Acox1 gene, which is a target of peroxisome proliferator-activated receptor α. Thus, the proposed method is a simple, sensitive and reliable tool for the quantitation of fibric acids working in vivo inside livers.

  4. Sensitivity analysis of a coupled hydrodynamic-vegetation model using the effectively subsampled quadratures method (ESQM v5.2)

    Science.gov (United States)

    Kalra, Tarandeep S.; Aretxabaleta, Alfredo; Seshadri, Pranay; Ganju, Neil K.; Beudin, Alexis

    2017-12-01

    Coastal hydrodynamics can be greatly affected by the presence of submerged aquatic vegetation. The effect of vegetation has been incorporated into the Coupled Ocean-Atmosphere-Wave-Sediment Transport (COAWST) modeling system. The vegetation implementation includes the plant-induced three-dimensional drag, in-canopy wave-induced streaming, and the production of turbulent kinetic energy by the presence of vegetation. In this study, we evaluate the sensitivity of the flow and wave dynamics to vegetation parameters using Sobol' indices and a least squares polynomial approach referred to as the Effective Quadratures method. This method reduces the number of simulations needed for evaluating Sobol' indices and provides a robust, practical, and efficient approach for the parameter sensitivity analysis. The evaluation of Sobol' indices shows that kinetic energy, turbulent kinetic energy, and water level changes are affected by plant stem density, height, and, to a lesser degree, diameter. Wave dissipation is mostly dependent on the variation in plant stem density. Performing sensitivity analyses for the vegetation module in COAWST provides guidance to optimize efforts and reduce exploration of parameter space for future observational and modeling work.

  5. Global and Local Sensitivity Analysis Methods for a Physical System

    Science.gov (United States)

    Morio, Jerome

    2011-01-01

    Sensitivity analysis is the study of how the different input variations of a mathematical model influence the variability of its output. In this paper, we review the principle of global and local sensitivity analyses of a complex black-box system. A simulated case of application is given at the end of this paper to compare both approaches.…

  6. The diagnostic accuracy of serologic and molecular methods for detecting visceral leishmaniasis in HIV infected patients: meta-analysis.

    Directory of Open Access Journals (Sweden)

    Gláucia Fernandes Cota

    Full Text Available BACKGROUND: Human visceral leishmaniasis (VL, a potentially fatal disease, has emerged as an important opportunistic condition in HIV infected patients. In immunocompromised patients, serological investigation is considered not an accurate diagnostic method for VL diagnosis and molecular techniques seem especially promising. OBJECTIVE: This work is a comprehensive systematic review and meta-analysis to evaluate the accuracy of serologic and molecular tests for VL diagnosis specifically in HIV-infected patients. METHODS: Two independent reviewers searched PubMed and LILACS databases. The quality of studies was assessed by QUADAS score. Sensitivity and specificity were pooled separately and compared with overall accuracy measures: diagnostic odds ratio (DOR and symmetric summary receiver operating characteristic (sROC. RESULTS: Thirty three studies recruiting 1,489 patients were included. The following tests were evaluated: Immunofluorescence Antibody Test (IFAT, Enzyme linked immunosorbent assay (ELISA, immunoblotting (Blot, direct agglutination test (DAT and polimerase chain reaction (PCR in whole blood and bone marrow. Most studies were carried out in Europe. Serological tests varied widely in performance, but with overall limited sensitivity. IFAT had poor sensitivity ranging from 11% to 82%. DOR (95% confidence interval was higher for DAT 36.01 (9.95-130.29 and Blot 27.51 (9.27-81.66 than for IFAT 7.43 (3.08-1791 and ELISA 3.06 (0.71-13.10. PCR in whole blood had the highest DOR: 400.35 (58.47-2741.42. The accuracy of PCR based on Q-point was 0.95; 95%CI 0.92-0.97, which means good overall performance. CONCLUSION: Based mainly on evidence gained by infection with Leishmania infantum chagasi, serological tests should not be used to rule out a diagnosis of VL among the HIV-infected, but a positive test at even low titers has diagnostic value when combined with the clinical case definition. Considering the available evidence, tests based on DNA

  7. Highly sensitive electrochemical detection of human telomerase activity based on bio-barcode method.

    Science.gov (United States)

    Li, Ying; Liu, Bangwei; Li, Xia; Wei, Qingli

    2010-07-15

    In the present study, an electrochemical method for highly sensitive detection of human telomerase activity was developed based on bio-barcode amplification assay. Telomerase was extracted from HeLa cells, then the extract was mixed with telomerase substrate (TS) primer to perform extension reaction. The extension product was hybridized with the capture DNA immobilized on the Au electrode and then reacted with the signal DNA on Au nanoparticles to form a sandwich hybridization mode. Electrochemical signals were generated by chronocoulometric interrogation of [Ru(NH(3))(6)](3+) that quantitatively binds to the DNA on Au nanoparticles via electrostatic interaction. This method can detect the telomerase activity from as little as 10 cultured cancer cells without the polymerase chain reaction (PCR) amplification of telomerase extension product. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  8. New sensitive high-performance liquid chromatography-tandem mass spectrometry method for the detection of horse and pork in halal beef.

    Science.gov (United States)

    von Bargen, Christoph; Dojahn, Jörg; Waidelich, Dietmar; Humpf, Hans-Ulrich; Brockmeyer, Jens

    2013-12-11

    The accidental or fraudulent blending of meat from different species is a highly relevant aspect for food product quality control, especially for consumers with ethical concerns against species, such as horse or pork. In this study, we present a sensitive mass spectrometrical approach for the detection of trace contaminations of horse meat and pork and demonstrate the specificity of the identified biomarker peptides against chicken, lamb, and beef. Biomarker peptides were identified by a shotgun proteomic approach using tryptic digests of protein extracts and were verified by the analysis of 21 different meat samples from the 5 species included in this study. For the most sensitive peptides, a multiple reaction monitoring (MRM) method was developed that allows for the detection of 0.55% horse or pork in a beef matrix. To enhance sensitivity, we applied MRM(3) experiments and were able to detect down to 0.13% pork contamination in beef. To the best of our knowledge, we present here the first rapid and sensitive mass spectrometrical method for the detection of horse and pork by use of MRM and MRM(3).

  9. Calibration of the pressure sensitivity of microphones by a free-field method at frequencies up to 80 khz.

    Science.gov (United States)

    Zuckerwar, Allan J; Herring, G C; Elbing, Brian R

    2006-01-01

    A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal-incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the nonuniformity of the sound field and, as applied here, uses a 1/4-in. air-condenser pressure microphone as a known reference. Best results were obtained with a centrifugal fan, which is used as a random, broadband sound source. A broadband source minimizes reflection-related interferences that can plague FF measurements. Calibrations were performed on 1/4-in. FF air-condenser, electret, and microelectromechanical systems (MEMS) microphones in an anechoic chamber. The uncertainty of this FF method is estimated by comparing the pressure sensitivity of an air-condenser FF microphone, as derived from the FF measurement, with that of an electrostatic actuator calibration. The root-mean-square difference is found to be +/- 0.3 dB over the range 1-80 kHz, and the combined standard uncertainty of the FF method, including other significant contributions, is +/- 0.41 dB.

  10. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  11. The sensitivity of clinical diagnostic methods in the diagnosis of diabetic neuropathy.

    Science.gov (United States)

    Onde, M E; Ozge, A; Senol, M G; Togrol, E; Ozdag, F; Saracoglu, M; Misirli, H

    2008-01-01

    This study assessed the sensitivity of various methods for the clinical diagnosis of diabetic peripheral neuropathy. A total of 147 randomly selected patients with diabetes mellitus and 65 age- and sex-matched healthy controls were evaluated by various clinical (the neuropathy symptom score [NSS], the neuropathy disability score [NDS], vibration perception thresholds [VPTs], Tinel's sign and Phalen's sign), laboratory (fasting plasma glucose and glycosylated haemoglobin levels) and electro-physiological (nerve conduction studies, H-reflex and F-wave measurements) methods. In the patient group, 8.2% had an abnormal NSS, 28.5% had a positive Phalen's sign, 32.6% had a positive Tinel's sign, 42.8% had an abnormal VPT and 57.1% had an abnormal NDS. Significant correlations were found between electro-physiologically confirmed neuropathy and the two provocation tests and abnormal VPTs. In conclusion, assessment with a complete neurological examination and standard electrophysiological tests is very important for the diagnosis of diabetic peripheral neuropathy and the prevention of morbidity in patients with or without symptoms.

  12. Serodiagnosis of human neurocysticercosis using antigenic components of Taenia solium metacestodes derived from the unbound fraction from jacalin affinity chromatography

    Directory of Open Access Journals (Sweden)

    Gleyce Alves Machado

    2013-05-01

    Full Text Available The aim of the present study was to analyse Taenia solium metacestode antigens that were derived from the unbound fraction of jacalin affinity chromatography and subsequent tert-octylphenoxy poly (oxyethylene ethanol Triton X-114 (TX-114 partitioning in the diagnosis of human neurocysticercosis (NCC. Immunoassays were designed to detect T. solium-specific IgG antibodies by ELISA and immunoblot. Serum samples were collected from 132 individuals who were categorised as follows: 40 had NCC, 62 presented Taenia spp or other parasitic diseases and 30 were healthy individuals. The jacalin-unbound (J unbound fraction presented higher sensitivity and specificity rates than the jacalin-bound fraction and only this fraction was subjected to subsequent TX-114 partitioning, resulting in detergent (DJ unbound and aqueous (AJ unbound fractions. The ELISA sensitivity and specificity were 85% and 84.8% for J unbound , 92.5% and 93.5% for DJ unbound and 82.5% and 82.6% for AJ unbound . By immunoblot, the DJ unbound fraction showed 100% sensitivity and specificity and only serum samples from patients with NCC recognised the 50-70 kDa T. solium-specific components. We conclude that the DJ unbound fraction can serve as a useful tool for the differential immunodiagnosis of NCC by immunoblot.

  13. A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

    Science.gov (United States)

    Mulligan, Jeffrey B.

    2016-01-01

    Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

  14. A non-contact, thermal noise based method for the calibration of lateral deflection sensitivity in atomic force microscopy

    International Nuclear Information System (INIS)

    Mullin, Nic; Hobbs, Jamie K.

    2014-01-01

    Calibration of lateral forces and displacements has been a long standing problem in lateral force microscopies. Recently, it was shown by Wagner et al. that the thermal noise spectrum of the first torsional mode may be used to calibrate the deflection sensitivity of the detector. This method is quick, non-destructive and may be performed in situ in air or liquid. Here we make a full quantitative comparison of the lateral inverse optical lever sensitivity obtained by the lateral thermal noise method and the shape independent method developed by Anderson et al. We find that the thermal method provides accurate results for a wide variety of rectangular cantilevers, provided that the geometry of the cantilever is suitable for torsional stiffness calibration by the torsional Sader method, in-plane bending of the cantilever may be eliminated or accounted for and that any scaling of the lateral deflection signal between the measurement of the lateral thermal noise and the measurement of the lateral deflection is eliminated or corrected for. We also demonstrate that the thermal method may be used to characterize the linearity of the detector signal as a function of position, and find a deviation of less than 8% for the instrument used

  15. UV-sensitive photoreceptor protein OPN5 in humans and mice.

    Science.gov (United States)

    Kojima, Daisuke; Mori, Suguru; Torii, Masaki; Wada, Akimori; Morishita, Rika; Fukada, Yoshitaka

    2011-01-01

    A variety of animal species utilize the ultraviolet (UV) component of sunlight as their environmental cues, whereas physiological roles of UV photoreception in mammals, especially in human beings, remain open questions. Here we report that mouse neuropsin (OPN5) encoded by the Opn5 gene exhibited an absorption maximum (λmax) at 380 nm when reconstituted with 11-cis-retinal. Upon UV-light illumination, OPN5 was converted to a blue-absorbing photoproduct (λmax 470 nm), which was stable in the dark and reverted to the UV-absorbing state by the subsequent orange light illumination, indicating its bistable nature. Human OPN5 also had an absorption maximum at 380 nm with spectral properties similar to mouse OPN5, revealing that OPN5 is the first and hitherto unknown human opsin with peak sensitivity in the UV region. OPN5 was capable of activating heterotrimeric G protein Gi in a UV-dependent manner. Immuno-blotting analyses of mouse tissue extracts identified the retina, the brain and, unexpectedly, the outer ears as the major sites of OPN5 expression. In the tissue sections of mice, OPN5 immuno-reactivities were detected in a subset of non-rod/non-cone retinal neurons as well as in the epidermal and muscle cells of the outer ears. Most of these OPN5-immuno-reactivities in mice were co-localized with positive signals for the alpha-subunit of Gi. These results demonstrate the first example of UV photoreceptor in human beings and strongly suggest that OPN5 triggers a UV-sensitive Gi-mediated signaling pathway in the mammalian tissues.

  16. Sensitivity analysis and comparison of two methods of using heart rate to represent energy expenditure during walking.

    Science.gov (United States)

    Karimi, Mohammad Taghi

    2015-01-01

    Heart rate is an accurate and easy to use method to represent the energy expenditure during walking, based on physiological cost index (PCI). However, in some conditions the heart rate during walking does not reach to a steady state. Therefore, it is not possible to determine the energy expenditure by use of the PCI index. The total heart beat index (THBI) is a new method to solve the aforementioned problem. The aim of this research project was to find the sensitivity of both the physiological cost index (PCI) and total heart beat index (THBI). Fifteen normal subjects and ten patients with flatfoot disorder and two subjects with spinal cord injury were recruited in this research project. The PCI and THBI indexes were determined by use of heart beats with respect to walking speed and total distance walked, respectively. The sensitivity of PCI was more than that of THBI index in the three groups of subjects. Although the PCI and THBI indexes are easy to use and reliable parameters to represent the energy expenditure during walking, their sensitivity is not high to detect the influence of some orthotic interventions, such as use of insoles or using shoes on energy expenditure during walking.

  17. The use of carbon black-TiO2 composite prepared using solid state method as counter electrode and E. conferta as sensitizer for dye-sensitized solar cell (DSSC) applications

    Science.gov (United States)

    Jaafar, Hidayani; Ahmad, Zainal Arifin; Ain, Mohd Fadzil

    2018-05-01

    In this paper, counter electrodes based on carbon black (CB)-TiO2 composite are proposed as a cost-effective alternative to conventional Pt counter electrodes used in dye-sensitized solar cell (DSSC) applications. CB-TiO2 composite counter electrodes with different weight percentages of CB were prepared using the solid state method and coated onto fluorine-doped tin oxide (FTO) glass using doctor blade method while Eleiodoxa conferta (E. conferta) and Nb-doped TiO2 were used as sensitizer and photoanode, respectively, with electrolyte containing I-/I-3 redox couple. The experimental results revealed that the CB-TiO2 composite influenced the photovoltaic performance by enhancing the electrocatalytic activity. As the amount of CB increased, the catalytic activity improved due to the increase in surface area which then led to low charge-transfer resistance (RCT) at the electrolyte/CB electrode interface. Due to the use of the modified photoanode together with natural dye sensitizers, the counter electrode based on 15 wt% CB-TiO2 composite was able to produce the highest energy conversion efficiency (2.5%) making it a viable alternative counter electrode.

  18. The pointillism method for creating stimuli suitable for use in computer-based visual contrast sensitivity testing.

    Science.gov (United States)

    Turner, Travis H

    2005-03-30

    An increasingly large corpus of clinical and experimental neuropsychological research has demonstrated the utility of measuring visual contrast sensitivity. Unfortunately, existing means of measuring contrast sensitivity can be prohibitively expensive, difficult to standardize, or lack reliability. Additionally, most existing tests do not allow full control over important characteristics, such as off-angle rotations, waveform, contrast, and spatial frequency. Ideally, researchers could manipulate characteristics and display stimuli in a computerized task designed to meet experimental needs. Thus far, 256-bit color limitation in standard cathode ray tube (CRT) monitors has been preclusive. To this end, the pointillism method (PM) was developed. Using MATLAB software, stimuli are created based on both mathematical and stochastic components, such that differences in regional luminance values of the gradient field closely approximate the desired contrast. This paper describes the method and examines its performance in sine and square-wave image sets from a range of contrast values. Results suggest the utility of the method for most experimental applications. Weaknesses in the current version, the need for validation and reliability studies, and considerations regarding applications are discussed. Syntax for the program is provided in an appendix, and a version of the program independent of MATLAB is available from the author.

  19. Uncertainty and sensitivity assessments of an agricultural-hydrological model (RZWQM2) using the GLUE method

    Science.gov (United States)

    Sun, Mei; Zhang, Xiaolin; Huo, Zailin; Feng, Shaoyuan; Huang, Guanhua; Mao, Xiaomin

    2016-03-01

    Quantitatively ascertaining and analyzing the effects of model uncertainty on model reliability is a focal point for agricultural-hydrological models due to more uncertainties of inputs and processes. In this study, the generalized likelihood uncertainty estimation (GLUE) method with Latin hypercube sampling (LHS) was used to evaluate the uncertainty of the RZWQM-DSSAT (RZWQM2) model outputs responses and the sensitivity of 25 parameters related to soil properties, nutrient transport and crop genetics. To avoid the one-sided risk of model prediction caused by using a single calibration criterion, the combined likelihood (CL) function integrated information concerning water, nitrogen, and crop production was introduced in GLUE analysis for the predictions of the following four model output responses: the total amount of water content (T-SWC) and the nitrate nitrogen (T-NIT) within the 1-m soil profile, the seed yields of waxy maize (Y-Maize) and winter wheat (Y-Wheat). In the process of evaluating RZWQM2, measurements and meteorological data were obtained from a field experiment that involved a winter wheat and waxy maize crop rotation system conducted from 2003 to 2004 in southern Beijing. The calibration and validation results indicated that RZWQM2 model can be used to simulate the crop growth and water-nitrogen migration and transformation in wheat-maize crop rotation planting system. The results of uncertainty analysis using of GLUE method showed T-NIT was sensitive to parameters relative to nitrification coefficient, maize growth characteristics on seedling period, wheat vernalization period, and wheat photoperiod. Parameters on soil saturated hydraulic conductivity, nitrogen nitrification and denitrification, and urea hydrolysis played an important role in crop yield component. The prediction errors for RZWQM2 outputs with CL function were relatively lower and uniform compared with other likelihood functions composed of individual calibration criterion. This

  20. A high-sensitive and quantitative in-line monitoring method for transplutonium elements separation processes

    International Nuclear Information System (INIS)

    Zhu Rongbao; Wang Shiju; Xu Yingpu; Zhang Zengrui

    1986-04-01

    A high-sensitive monitoring device and a quantitative analys technigue for transplutonium elements separation processes are described. X-ray and low energy γ-ray are measured by means of a scintillation monitor with two NaI(Tl) thin crystals. The α spectra of the fluents of ion-exchange column is measured by means of Si(Au) surface barrier in-line monitor. The construction of the monitors, auxiliary electronics, investigation result for the α spectra character of thick source and the calibration method were described. The determination results for extracting process of 243 Am and 244 Cm by ion-exchange chromatography were given. The sensitivity of total adding amount for 243 Am using the 4π scintillation monitor is better than 0.1 μCi. The precision of 243 Am and 244 Cm concentration determination using Si(Au) monitor is +- 5%. The precision of the two metals contents in containers is about +- 10%

  1. High-resolution slab gel isoelectric focusing: methods for quantitative electrophoretic transfer and immunodetection of proteins as applied to the study of the multiple isoelectric forms of ornithine decarboxylase.

    Science.gov (United States)

    Reddy, S G; Cochran, B J; Worth, L L; Knutson, V P; Haddox, M K

    1994-04-01

    A high-resolution isoelectric focusing vertical slab gel method which can resolve proteins which differ by a single charge was developed and this method was applied to the study of the multiple isoelectric forms of ornithine decarboxylase. Separation of proteins at this high level of resolution was achieved by increasing the ampholyte concentration in the gels to 6%. Various lots of ampholytes, from the same or different commercial sources, differed significantly in their protein binding capacity. Ampholytes bound to proteins interfered both with the electrophoretic transfer of proteins from the gel to immunoblotting membranes and with the ability of antibodies to interact with proteins on the immunoblotting membranes. Increasing the amount of protein loaded into a gel lane also decreased the efficiency of the electrophoretic transfer and immunodetection. To overcome these problems, both gel washing and gel electrophoretic transfer protocols for disrupting the ampholyte-protein binding and enabling a quantitative electrophoretic transfer of proteins were developed. Two gel washing procedures, with either thiocyanate or borate buffers, and a two-step electrophoretic transfer method are described. The choice of which method to use to optimally disrupt the ampholyte-protein binding was found to vary with each lot of ampholytes employed.

  2. Sensitive silicon PIN-diode dosimeter for fast neutrons and method to control and increase its sensitivity

    International Nuclear Information System (INIS)

    Swinehart, P.R.; Swartz, J.M.

    1978-01-01

    With the personnel dosimeter, applicable e.g. in medicine, a dose of 0.1 rad for neutrons with an energy greater than 10 keV can be detected. In the range between 0.1 and 20 rad sensitivity is increased to 5 mV/rad. This sensitivity can be achieved by distributing the mass of the semiconductor material of the diode or equal to four times the reciprocal base width. Appropriate dimensions are 750 μm for the edge length of the end surface resp. diameter and 750 μm up to 5000 μm for the base width. (DG) [de

  3. Radiation-sensitive compounds and methods of using same

    International Nuclear Information System (INIS)

    DeMajistre, R.

    1977-01-01

    Novel diacrylates are prepared by reacting a monohydroxylated acrylic monomer with a polyisocyanate. The reaction product may be polymerized by subjecting to ionizing irradiation, actinic light or to free radical catalysis to form a useful coating material. The diacrylates may also be copolymerized with other radiation sensitive materials

  4. Sensitivity analysis of a coupled hydrodynamic-vegetation model using the effectively subsampled quadratures method (ESQM v5.2

    Directory of Open Access Journals (Sweden)

    T. S. Kalra

    2017-12-01

    Full Text Available Coastal hydrodynamics can be greatly affected by the presence of submerged aquatic vegetation. The effect of vegetation has been incorporated into the Coupled Ocean–Atmosphere–Wave–Sediment Transport (COAWST modeling system. The vegetation implementation includes the plant-induced three-dimensional drag, in-canopy wave-induced streaming, and the production of turbulent kinetic energy by the presence of vegetation. In this study, we evaluate the sensitivity of the flow and wave dynamics to vegetation parameters using Sobol' indices and a least squares polynomial approach referred to as the Effective Quadratures method. This method reduces the number of simulations needed for evaluating Sobol' indices and provides a robust, practical, and efficient approach for the parameter sensitivity analysis. The evaluation of Sobol' indices shows that kinetic energy, turbulent kinetic energy, and water level changes are affected by plant stem density, height, and, to a lesser degree, diameter. Wave dissipation is mostly dependent on the variation in plant stem density. Performing sensitivity analyses for the vegetation module in COAWST provides guidance to optimize efforts and reduce exploration of parameter space for future observational and modeling work.

  5. A practical sensitivity analysis method for ranking sources of uncertainty in thermal–hydraulics applications

    Energy Technology Data Exchange (ETDEWEB)

    Pourgol-Mohammad, Mohammad, E-mail: pourgolmohammad@sut.ac.ir [Department of Mechanical Engineering, Sahand University of Technology, Tabriz (Iran, Islamic Republic of); Hoseyni, Seyed Mohsen [Department of Basic Sciences, East Tehran Branch, Islamic Azad University, Tehran (Iran, Islamic Republic of); Hoseyni, Seyed Mojtaba [Building & Housing Research Center, Tehran (Iran, Islamic Republic of); Sepanloo, Kamran [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of)

    2016-08-15

    Highlights: • Existing uncertainty ranking methods prove inconsistent for TH applications. • Introduction of a new method for ranking sources of uncertainty in TH codes. • Modified PIRT qualitatively identifies and ranks uncertainty sources more precisely. • The importance of parameters is calculated by a limited number of TH code executions. • Methodology is applied successfully on LOFT-LB1 test facility. - Abstract: In application to thermal–hydraulic calculations by system codes, sensitivity analysis plays an important role for managing the uncertainties of code output and risk analysis. Sensitivity analysis is also used to confirm the results of qualitative Phenomena Identification and Ranking Table (PIRT). Several methodologies have been developed to address uncertainty importance assessment. Generally, uncertainty importance measures, mainly devised for the Probabilistic Risk Assessment (PRA) applications, are not affordable for computationally demanding calculations of the complex thermal–hydraulics (TH) system codes. In other words, for effective quantification of the degree of the contribution of each phenomenon to the total uncertainty of the output, a practical approach is needed by considering high computational burden of TH calculations. This study aims primarily to show the inefficiency of the existing approaches and then introduces a solution to cope with the challenges in this area by modification of variance-based uncertainty importance method. Important parameters are identified by the modified PIRT approach qualitatively then their uncertainty importance is quantified by a local derivative index. The proposed index is attractive from its practicality point of view on TH applications. It is capable of calculating the importance of parameters by a limited number of TH code executions. Application of the proposed methodology is demonstrated on LOFT-LB1 test facility.

  6. A practical sensitivity analysis method for ranking sources of uncertainty in thermal–hydraulics applications

    International Nuclear Information System (INIS)

    Pourgol-Mohammad, Mohammad; Hoseyni, Seyed Mohsen; Hoseyni, Seyed Mojtaba; Sepanloo, Kamran

    2016-01-01

    Highlights: • Existing uncertainty ranking methods prove inconsistent for TH applications. • Introduction of a new method for ranking sources of uncertainty in TH codes. • Modified PIRT qualitatively identifies and ranks uncertainty sources more precisely. • The importance of parameters is calculated by a limited number of TH code executions. • Methodology is applied successfully on LOFT-LB1 test facility. - Abstract: In application to thermal–hydraulic calculations by system codes, sensitivity analysis plays an important role for managing the uncertainties of code output and risk analysis. Sensitivity analysis is also used to confirm the results of qualitative Phenomena Identification and Ranking Table (PIRT). Several methodologies have been developed to address uncertainty importance assessment. Generally, uncertainty importance measures, mainly devised for the Probabilistic Risk Assessment (PRA) applications, are not affordable for computationally demanding calculations of the complex thermal–hydraulics (TH) system codes. In other words, for effective quantification of the degree of the contribution of each phenomenon to the total uncertainty of the output, a practical approach is needed by considering high computational burden of TH calculations. This study aims primarily to show the inefficiency of the existing approaches and then introduces a solution to cope with the challenges in this area by modification of variance-based uncertainty importance method. Important parameters are identified by the modified PIRT approach qualitatively then their uncertainty importance is quantified by a local derivative index. The proposed index is attractive from its practicality point of view on TH applications. It is capable of calculating the importance of parameters by a limited number of TH code executions. Application of the proposed methodology is demonstrated on LOFT-LB1 test facility.

  7. Acquisition and processing method for human sensorial, sensitive, motory and phonatory circuits reaction times

    International Nuclear Information System (INIS)

    Doche, Claude

    1972-01-01

    This work describes a storage and acquisition device and a method for human sensorial and sensitive motory and phonatory reaction times. The considered circuits are those made with the visual, auditory and sensory receptor organs and the motory or phonatory effector organs. The anatomo-physiological localization of these circuits allows us to appreciate the possibilities of the central nervous system for different angles. The experimental population is made of normal and pathological individuals (individuals having tumoral or vascular, localized or diffused cerebral lesions or parkinsonian individuals). The parameter processing method is based on the multivariate analysis results and allows us to position each individual compared to a normal individual and to appreciate the weight of each circuit in this positioning. Clinical exploitation results give to this method a prognosis and therapeutic interest. It seems though untimely to talk about its diagnosis value. (author) [fr

  8. Sensitivity and uncertainty analysis

    CERN Document Server

    Cacuci, Dan G; Navon, Ionel Michael

    2005-01-01

    As computer-assisted modeling and analysis of physical processes have continued to grow and diversify, sensitivity and uncertainty analyses have become indispensable scientific tools. Sensitivity and Uncertainty Analysis. Volume I: Theory focused on the mathematical underpinnings of two important methods for such analyses: the Adjoint Sensitivity Analysis Procedure and the Global Adjoint Sensitivity Analysis Procedure. This volume concentrates on the practical aspects of performing these analyses for large-scale systems. The applications addressed include two-phase flow problems, a radiative c

  9. Sensitivity study of a method for updating a finite element model of a nuclear power station cooling tower

    International Nuclear Information System (INIS)

    Billet, L.

    1994-01-01

    The Research and Development Division of Electricite de France is developing a surveillance method of cooling towers involving on-site wind-induced measurements. The method is supposed to detect structural damage in the tower. The damage is identified by tuning a finite element model of the tower on experimental mode shapes and eigenfrequencies. The sensitivity of the method was evaluated through numerical tests. First, the dynamic response of a damaged tower was simulated by varying the stiffness of some area of the model shell (from 1 % to 24 % of the total shell area). Second, the structural parameters of the undamaged cooling tower model were updated in order to make the output of the undamaged model as close as possible to the synthetic experimental data. The updating method, based on the minimization of the differences between experimental modal energies and modal energies calculated by the model, did not detect a stiffness change over less than 3 % of the shell area. Such a sensitivity is thought to be insufficient to detect tower cracks which behave like highly localized defaults. (author). 8 refs., 9 figs., 6 tabs

  10. An Adjoint Sensitivity Method Applied to Time Reverse Imaging of Tsunami Source for the 2009 Samoa Earthquake

    Science.gov (United States)

    Hossen, M. Jakir; Gusman, Aditya; Satake, Kenji; Cummins, Phil R.

    2018-01-01

    We have previously developed a tsunami source inversion method based on "Time Reverse Imaging" and demonstrated that it is computationally very efficient and has the ability to reproduce the tsunami source model with good accuracy using tsunami data of the 2011 Tohoku earthquake tsunami. In this paper, we implemented this approach in the 2009 Samoa earthquake tsunami triggered by a doublet earthquake consisting of both normal and thrust faulting. Our result showed that the method is quite capable of recovering the source model associated with normal and thrust faulting. We found that the inversion result is highly sensitive to some stations that must be removed from the inversion. We applied an adjoint sensitivity method to find the optimal set of stations in order to estimate a realistic source model. We found that the inversion result is improved significantly once the optimal set of stations is used. In addition, from the reconstructed source model we estimated the slip distribution of the fault from which we successfully determined the dipping orientation of the fault plane for the normal fault earthquake. Our result suggests that the fault plane dip toward the northeast.

  11. Sensitivity in risk analyses with uncertain numbers.

    Energy Technology Data Exchange (ETDEWEB)

    Tucker, W. Troy; Ferson, Scott

    2006-06-01

    Sensitivity analysis is a study of how changes in the inputs to a model influence the results of the model. Many techniques have recently been proposed for use when the model is probabilistic. This report considers the related problem of sensitivity analysis when the model includes uncertain numbers that can involve both aleatory and epistemic uncertainty and the method of calculation is Dempster-Shafer evidence theory or probability bounds analysis. Some traditional methods for sensitivity analysis generalize directly for use with uncertain numbers, but, in some respects, sensitivity analysis for these analyses differs from traditional deterministic or probabilistic sensitivity analyses. A case study of a dike reliability assessment illustrates several methods of sensitivity analysis, including traditional probabilistic assessment, local derivatives, and a ''pinching'' strategy that hypothetically reduces the epistemic uncertainty or aleatory uncertainty, or both, in an input variable to estimate the reduction of uncertainty in the outputs. The prospects for applying the methods to black box models are also considered.

  12. A rapid and efficient two-step gel electrophoresis method for the purification of major rye grass pollen allergens.

    Science.gov (United States)

    Levy, D; Davies, J; O'Hehir, R; Suphioglu, C

    2001-06-01

    Purified proteins are mandatory for molecular, immunological and cellular studies. However, purification of proteins from complex mixtures requires specialised chromatography methods (i.e., gel filtration, ion exchange, etc.) using fast protein liquid chromatography (FPLC) or high-performance liquid chromatography (HPLC) systems. Such systems are expensive and certain proteins require two or more different steps for sufficient purity and generally result in low recovery. The aim of this study was to develop a rapid, inexpensive and efficient gel-electrophoresis-based protein purification method using basic and readily available laboratory equipment. We have used crude rye grass pollen extract to purify the major allergens Lol p 1 and Lol p 5 as the model protein candidates. Total proteins were resolved on large primary gel and Coomassie Brilliant Blue (CBB)-stained Lol p 1/5 allergens were excised and purified on a secondary "mini"-gel. Purified proteins were extracted from unstained separating gels and subjected to sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and immunoblot analyses. Silver-stained SDS-PAGE gels resolved pure proteins (i.e., 875 microg of Lol p 1 recovered from a 8 mg crude starting material) while immunoblot analysis confirmed immunological reactivity of the purified proteins. Such a purification method is rapid, inexpensive, and efficient in generating proteins of sufficient purity for use in monoclonal antibody (mAb) production, protein sequencing and general molecular, immunological, and cellular studies.

  13. [Better performance of Western blotting: quick vs slow protein transfer, blotting membranes and the visualization methods].

    Science.gov (United States)

    Kong, Ling-Quan; Pu, Ying-Hui; Ma, Shi-Kun

    2008-01-01

    To study how the choices of the quick vs slow protein transfer, the blotting membranes and the visualization methods influence the performance of Western blotting. The cellular proteins were abstracted from human breast cell line MDA-MB-231 for analysis with Western blotting using quick (2 h) and slow (overnight) protein transfer, different blotting membranes (nitrocellulose, PVDF and nylon membranes) and different visualization methods (ECL and DAB). In Western blotting with slow and quick protein transfer, the prestained marker presented more distinct bands on nitrocellulose membrane than on the nylon and PVDF membranes, and the latter also showed clear bands on the back of the membrane to very likely cause confusion, which did not occur with nitrocellulose membrane. PVDF membrane allowed slightly clearer visualization of the proteins with DAB method as compared with nitrocellulose and nylon membranes, and on the latter two membranes, quick protein transfer was likely to result in somehow irregular bands in comparison with slow protein transfer. With slow protein transfer and chemiluminescence for visualization, all the 3 membranes showed clear background, while with quick protein transfer, nylon membrane gave rise to obvious background noise but the other two membranes did not. Different membranes should be selected for immunoblotting according to the actual needs of the experiment. Slow transfer of the proteins onto the membranes often has better effect than quick transfer, and enhanced chemiluminescence is superior to DAB for protein visualization and allows highly specific and sensitive analysis of the protein expressions.

  14. Mehar Methods for Fuzzy Optimal Solution and Sensitivity Analysis of Fuzzy Linear Programming with Symmetric Trapezoidal Fuzzy Numbers

    Directory of Open Access Journals (Sweden)

    Sukhpreet Kaur Sidhu

    2014-01-01

    Full Text Available The drawbacks of the existing methods to obtain the fuzzy optimal solution of such linear programming problems, in which coefficients of the constraints are represented by real numbers and all the other parameters as well as variables are represented by symmetric trapezoidal fuzzy numbers, are pointed out, and to resolve these drawbacks, a new method (named as Mehar method is proposed for the same linear programming problems. Also, with the help of proposed Mehar method, a new method, much easy as compared to the existing methods, is proposed to deal with the sensitivity analysis of the same type of linear programming problems.

  15. Standard test method for electrochemical reactivation (EPR) for detecting sensitization of AISI type 304 and 304L stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers a laboratory procedure for conducting an electrochemical reactivation (EPR) test on AISI Type 304 and 304L (UNS No. S30400 and S30403, respectively) stainless steels. This test method can provide a nondestructive means of quantifying the degree of sensitization in these steels (1, 2, 3). This test method has found wide acceptance in studies of the effects of sensitization on intergranular corrosion and intergranular stress corrosion cracking behavior (see Terminology G15). The EPR technique has been successfully used to evaluate other stainless steels and nickel base alloys (4), but the test conditions and evaluation criteria used were modified in each case from those cited in this test method. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this...

  16. Homologous Recombination Defective Arabidopsis Mutants Exhibit Enhanced Sensitivity to Abscisic Acid.

    Directory of Open Access Journals (Sweden)

    Sujit Roy

    Full Text Available Abscisic acid (ABA acts as an important plant hormone in regulating various aspects of plant growth and developmental processes particularly under abiotic stress conditions. An increased ABA level in plant cells inhibits DNA replication and cell division, causing plant growth retardation. In this study, we have investigated the effects of ABA on the growth responses of some major loss-of-function mutants of DNA double-stand break (DSB repair genes in Arabidopsis during seed germination and early stages of seedling growth for understanding the role of ABA in the induction of genome instability in plants. A comparative analysis of ABA sensitivity of wild-type Arabidopsis and the knockout mutant lines related to DSB sensors, including atatm, atatr, the non-homologous end joining (NHEJ pathway genes, and mutants related to homologous recombination (HR pathway genes showed relatively enhanced sensitivity of atatr and HR-related mutants to ABA treatment. The expression levels of HR-related genes were increased in wild-type Arabidopsis (Col-0 during seed germination and early stages of seedling growth. Immunoblotting experiments detected phosphorylation of histone H2AX in wild-type (Col-0 and DSB repair gene mutants after ABA treatment, indicating the activation of DNA damage response due to ABA treatment. Analyses of DSB repair kinetics using comet assay under neutral condition have revealed comparatively slower DSB repair activity in HR mutants. Overall, our results have provided comprehensive information on the possible effect of ABA on DNA repair machinery in plants and also indicated potential functional involvement of HR pathway in repairing ABA induced DNA damage in Arabidopsis.

  17. Post-staining electroblotting for efficient and reliable peptide blotting.

    Science.gov (United States)

    Lee, Der-Yen; Chang, Geen-Dong

    2015-01-01

    Post-staining electroblotting has been previously described to transfer Coomassie blue-stained proteins from polyacrylamide gel onto polyvinylidene difluoride (PVDF) membranes. Actually, stained peptides can also be efficiently and reliably transferred. Because of selective staining procedures for peptides and increased retention of stained peptides on the membrane, even peptides with molecular masses less than 2 kDa such as bacitracin and granuliberin R are transferred with satisfactory results. For comparison, post-staining electroblotting is about 16-fold more sensitive than the conventional electroblotting for visualization of insulin on the membrane. Therefore, the peptide blots become practicable and more accessible to further applications, e.g., blot overlay detection or immunoblotting analysis. In addition, the efficiency of peptide transfer is favorable for N-terminal sequence analysis. With this method, peptide blotting can be normalized for further analysis such as blot overlay assay, immunoblotting, and N-terminal sequencing for identification of peptide in crude or partially purified samples.

  18. Sensitivity analysis of an environmental model: an application of different analysis methods

    International Nuclear Information System (INIS)

    Campolongo, Francesca; Saltelli, Andrea

    1997-01-01

    A parametric sensitivity analysis (SA) was conducted on a well known model for the production of a key sulphur bearing compound from algal biota. The model is of interest because of the climatic relevance of the gas (dimethylsulphide, DMS), an initiator of cloud particles. A screening test at low sample size is applied first (Morris method) followed by a computationally intensive variance based measure. Standardised regression coefficients are also computed. The various SA measures are compared with each other, and the use of bootstrap is suggested to extract empirical confidence bounds on the SA estimators. For some of the input factors, investigators guess about the parameters relevance was confirmed; for some others, the results shed new light on the system mechanism and on the data parametrisation

  19. Assessment of the Allergenic Potential of Transgenic Wheat (Triticum aestivum) with Reduced Levels of ω5-Gliadins, the Major Sensitizing Allergen in Wheat-Dependent Exercise-Induced Anaphylaxis.

    Science.gov (United States)

    Altenbach, Susan B; Tanaka, Charlene K; Pineau, Florence; Lupi, Roberta; Drouet, Martine; Beaudouin, Etienne; Morisset, Martine; Denery-Papini, Sandra

    2015-10-28

    The ω5-gliadins are the major sensitizing allergens in wheat-dependent exercise-induced anaphylaxis (WDEIA). In this study, two-dimensional immunoblot analysis was used to assess the allergenic potential of two transgenic wheat lines in which ω5-gliadin genes were silenced by RNA interference. Sera from 7 of 11 WDEIA patients showed greatly reduced levels of immunoglobulin E (IgE) reactivity to ω5-gliadins in both transgenic lines. However, these sera also showed low levels of reactivity to other gluten proteins. Sera from three patients showed the greatest reactivity to proteins other than ω5-gliadins, either high-molecular-weight glutenin subunits (HMW-GSs), α-gliadins, or non-gluten proteins. The complexity of immunological responses among these patients suggests that flour from the transgenic lines would not be suitable for individuals already diagnosed with WDEIA. However, the introduction of wheat lacking ω5-gliadins could reduce the number of people sensitized to these proteins and thereby decrease the overall incidence of this serious food allergy.

  20. Determination of paraquat in water samples using a sensitive fluorescent probe titration method.

    Science.gov (United States)

    Yao, Feihu; Liu, Hailong; Wang, Guangquan; Du, Liming; Yin, Xiaofen; Fu, Yunlong

    2013-06-01

    Paraquat (PQ), a nonselective herbicide, is non-fluorescent in aqueous solutions. Thus, its determination through direct fluorescent methods is not feasible. The supramolecular inclusion interaction of PQ with cucurbit[7]uril was studied by a fluorescent probe titration method. Significant quenching of the fluorescence intensity of the cucurbit[7]uril-coptisine fluorescent probe was observed with the addition of PQ. A new fluorescent probe titration method with high selectivity and sensitivity at the ng/mL level was developed to determine PQ in aqueous solutions with good precision and accuracy based on the significant quenching of the supramolecular complex fluorescence intensity. The proposed method was successfully used in the determination of PQ in lake water, tap water, well water, and ditch water in an agricultural area, with recoveries of 96.73% to 105.77%. The fluorescence quenching values (deltaF) showed a good linear relationship with PQ concentrations from 1.0 x 10(-8) to 1.2 x 10(-5) mol/L with a detection limit of 3.35 x 10(-9) mol/L. In addition, the interaction models of the supramolecular complexes formed between the host and the guest were established using theoretical calculations. The interaction mechanism between the cucurbit[7]uril and PQ was confirmed by 1H NMR spectroscopy.

  1. Sensitivity analysis of the use of Life Cycle Impact Assessment methods: a case study on building materials

    DEFF Research Database (Denmark)

    Bueno, Cristiane; Hauschild, Michael Zwicky; Rossignolo, Joao Adriano

    2016-01-01

    The main aim of this research is to perform a sensitivity analysis of a Life Cycle Assessment (LCA) case study to understand if the use of different Life Cycle Impact Assessment (LCIA) methods may lead to different conclusions by decision makers and stakeholders. A complete LCA was applied to non...

  2. NCX-4040, a nitric oxide-releasing aspirin, sensitizes drug-resistant human ovarian xenograft tumors to cisplatin by depletion of cellular thiols

    Directory of Open Access Journals (Sweden)

    Ignarro Louis J

    2008-02-01

    Full Text Available Abstract Background Ovarian carcinoma is the leading cause of mortality among gynecological cancers in the world. The high mortality rate is associated with lack of early diagnosis and development of drug resistance. The antitumor efficacy and mechanism of NCX-4040, a nitric oxide-releasing aspirin derivative, against ovarian cancer is studied. Methods NCX-4040, alone or in combination with cisplatin (cis-diamminedichloroplatinum, cDDP, was studied in cisplatin-sensitive (A2780 WT and cisplatin-resistant (A2780 cDDP cell lines as well as xenograft tumors grown in nude mice. Electron paramagnetic resonance (EPR was used for measurements of nitric oxide and redox state. Immunoblotting analysis of A2780 cDDP tumor xenografts from mice was used for mechanistic studies. Results Cells treated with NCX-4040 (25 μM showed a significant reduction of cell viability (A2780 WT, 34.9 ± 8.7%; A2780 cDDP, 41.7 ± 7.6%; p versus NCX-4040+cisplatin, 26.4 ± 7.6%; p versus NCX-4040+cisplatin, 56.4 ± 7.8%; p Conclusion The results suggested that NCX-4040 could resensitize drug-resistant ovarian cancer cells to cisplatin possibly by depletion of cellular thiols. Thus NCX-4040 appears to be a potential therapeutic agent for the treatment of human ovarian carcinoma and cisplatin-resistant malignancies.

  3. Radiation and thermal characteristics of L5178Y-sensitive cells and usefulness of eosin staining method to detect heat-induced cell death

    Energy Technology Data Exchange (ETDEWEB)

    Nishioka, Yasuji (Hiroshima Univ. (Japan). School of Medicine)

    1990-08-01

    Radiosensitivity, thermosensitivity, drug sensitivity and their combined effects were investigated in mouse L5178Y-wild cells (LY-W) and L5178Y-sensitive cells (LY-S). The following results were obtained: LY-S were more radiosensitive than LY-W but were similar in their thermosensitivity. Thermotolerance induction was similar but the decay was faster in LY-W which had a shorter doubling time. The radiosensitizing effect of heating was similar in both cell lines. The thermal enhancement ratio was higher for a longer duration of heating at 42degC than for a shorter duration at 44degC, both of which exhibited a similar level of survival when applied alone. The eosin staining method was useful to detect heat-induced interphase death and thermal sensitizing effects of drugs. In LY-W, interphase death was the main mode of hyperthermic cell killing and was independent of the hyperthermic temperature, whereas in LY-S, the percentage of interphase death increased with the hyperthermic temperature. Procaine and bleomycin sensitized both cells to heat. Survival estimated by the eosin staining method shifted towards that obtained by colony forming method in heated LY-S after procaine. Sensitization to heat by procaine suggests that interphase death after hyperthermia is probably due to membrane damage. Comparison of the present work with previous ones, further suggests that with an increase in thermosensitivity, there is an increase in heat-induced interphase death. (author) 67 refs.

  4. Radiation and thermal characteristics of L5178Y-sensitive cells and usefulness of eosin staining method to detect heat-induced cell death

    International Nuclear Information System (INIS)

    Nishioka, Yasuji

    1990-01-01

    Radiosensitivity, thermosensitivity, drug sensitivity and their combined effects were investigated in mouse L5178Y-wild cells (LY-W) and L5178Y-sensitive cells (LY-S). The following results were obtained: LY-S were more radiosensitive than LY-W but were similar in their thermosensitivity. Thermotolerance induction was similar but the decay was faster in LY-W which had a shorter doubling time. The radiosensitizing effect of heating was similar in both cell lines. The thermal enhancement ratio was higher for a longer duration of heating at 42degC than for a shorter duration at 44degC, both of which exhibited a similar level of survival when applied alone. The eosin staining method was useful to detect heat-induced interphase death and thermal sensitizing effects of drugs. In LY-W, interphase death was the main mode of hyperthermic cell killing and was independent of the hyperthermic temperature, whereas in LY-S, the percentage of interphase death increased with the hyperthermic temperature. Procaine and bleomycin sensitized both cells to heat. Survival estimated by the eosin staining method shifted towards that obtained by colony forming method in heated LY-S after procaine. Sensitization to heat by procaine suggests that interphase death after hyperthermia is probably due to membrane damage. Comparison of the present work with previous ones, further suggests that with an increase in thermosensitivity, there is an increase in heat-induced interphase death. (author) 67 refs

  5. A Sensitive and Specific PCR Based Method for Identification of Cryptosporidium Sp. Using New Primers from 18S Ribosomal RNA

    Directory of Open Access Journals (Sweden)

    M Heydarnezhadi

    2011-09-01

    Full Text Available Background: The main goal of the present study was to develop a new sensitive and specific PCR based method for Identification of Cryptosporidium sp. using novel primers from 18S ribosomal RNA. Cryptosporidi­osis in high-risk host groups particularly in neonates and immuno-compromised individuals may result in death. To the best of our knowledge this is the first study regarding develop a new PCR based method to diagnose the cryptosporidiosis in Iran.Methods: A total of 850 human fecal samples from patients clinically suspected to cryptosporidiosis and 100 healthy and diarrheic cattle stool specimens were collected. The simplified formol-ether concentration method was carried out for all samples. They were then examined microscopically by modified Ziehl-Neel­sen staining method. Total DNA was extracted by QIA amp DNA stool mini kit was carried out by using designed prim­ers.Results: Twenty nine cases of cryptosporidiosis infection in human and 30 samples from cattle microscopi­cally were posi­tive. The described primary and nested PCR method could detect all Cryptospori­dium positive samples from human and cattle. Regards to suspected negative samples in pri­mary PCR examination, the Nested PCR could ap­prove two more positive results. Furthermore, Nested PCR analysis was able to detect one more case which was nega­tive in both microscopically examination and primary PCR. Specificity of the test was 100%. Sensitivity of Nested PCR in comparison to our gold standard; microscopy after Ridley concentration modified ziehl-Neelsen, was 100 %.Conclusion: Our developed PCR based method by using new primers devised from 18S ribosomal RNA revealed the ability for identification of the Cryptosporidium species such as C. parvum and C. huminis with high specificity and sensitivity.

  6. Development of a rapid, simple and sensitive HPLC-FLD method for determination of rhodamine B in chili-containing products.

    Science.gov (United States)

    Qi, Ping; Lin, Zhihao; Li, Jiaxu; Wang, ChengLong; Meng, WeiWei; Hong, Hong; Zhang, Xuewu

    2014-12-01

    In this work, a simple, rapid and sensitive analytical method for the determination of rhodamine B in chili-containing foodstuffs is described. The dye is extracted from samples with methanol and analysed without further cleanup procedure by high-performance liquid chromatography (HPLC) coupled to fluorescence detection (FLD). The influence of matrix fluorescent compounds (capsaicin and dihydrocapsaicin) on the analysis was overcome by the optimisation of mobile-phase composition. The limit of determination (LOD) and limit of quantification (LOQ) were 3.7 and 10 μg/kg, respectively. Validation data show a good repeatability and within-lab reproducibility with relative standard deviations rhodamine B in foodstuffs. This method is suitable for the routine analysis of rhodamine B due to its sensitivity, simplicity, reasonable time and cost. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Parallel replica dynamics method for bistable stochastic reaction networks: Simulation and sensitivity analysis

    Science.gov (United States)

    Wang, Ting; Plecháč, Petr

    2017-12-01

    Stochastic reaction networks that exhibit bistable behavior are common in systems biology, materials science, and catalysis. Sampling of stationary distributions is crucial for understanding and characterizing the long-time dynamics of bistable stochastic dynamical systems. However, simulations are often hindered by the insufficient sampling of rare transitions between the two metastable regions. In this paper, we apply the parallel replica method for a continuous time Markov chain in order to improve sampling of the stationary distribution in bistable stochastic reaction networks. The proposed method uses parallel computing to accelerate the sampling of rare transitions. Furthermore, it can be combined with the path-space information bounds for parametric sensitivity analysis. With the proposed methodology, we study three bistable biological networks: the Schlögl model, the genetic switch network, and the enzymatic futile cycle network. We demonstrate the algorithmic speedup achieved in these numerical benchmarks. More significant acceleration is expected when multi-core or graphics processing unit computer architectures and programming tools such as CUDA are employed.

  8. Parallel replica dynamics method for bistable stochastic reaction networks: Simulation and sensitivity analysis.

    Science.gov (United States)

    Wang, Ting; Plecháč, Petr

    2017-12-21

    Stochastic reaction networks that exhibit bistable behavior are common in systems biology, materials science, and catalysis. Sampling of stationary distributions is crucial for understanding and characterizing the long-time dynamics of bistable stochastic dynamical systems. However, simulations are often hindered by the insufficient sampling of rare transitions between the two metastable regions. In this paper, we apply the parallel replica method for a continuous time Markov chain in order to improve sampling of the stationary distribution in bistable stochastic reaction networks. The proposed method uses parallel computing to accelerate the sampling of rare transitions. Furthermore, it can be combined with the path-space information bounds for parametric sensitivity analysis. With the proposed methodology, we study three bistable biological networks: the Schlögl model, the genetic switch network, and the enzymatic futile cycle network. We demonstrate the algorithmic speedup achieved in these numerical benchmarks. More significant acceleration is expected when multi-core or graphics processing unit computer architectures and programming tools such as CUDA are employed.

  9. A rapid chemical method for lysing Arabidopsis cells for protein analysis

    Directory of Open Access Journals (Sweden)

    Takano Tetsuo

    2011-07-01

    Full Text Available Abstract Background Protein extraction is a frequent procedure in biological research. For preparation of plant cell extracts, plant materials usually have to be ground and homogenized to physically break the robust cell wall, but this step is laborious and time-consuming when a large number of samples are handled at once. Results We developed a chemical method for lysing Arabidopsis cells without grinding. In this method, plants are boiled for just 10 minutes in a solution containing a Ca2+ chelator and detergent. Cell extracts prepared by this method were suitable for SDS-PAGE and immunoblot analysis. This method was also applicable to genomic DNA extraction for PCR analysis. Our method was applied to many other plant species, and worked well for some of them. Conclusions Our method is rapid and economical, and allows many samples to be prepared simultaneously for protein analysis. Our method is useful not only for Arabidopsis research but also research on certain other species.

  10. Determination of IgE antibodies to the benzylpenicilloyl determinant: a comparison of the sensitivity and specificity of three radio allergo sorbent test methods.

    Science.gov (United States)

    Garcia, J J; Blanca, M; Moreno, F; Vega, J M; Mayorga, C; Fernandez, J; Juarez, C; Romano, A; de Ramon, E

    1997-01-01

    The quantitation of in vitro IgE antibodies to the benzylpenicilloyl determinant (BPO) is a useful tool for evaluating suspected penicillin allergic subjects. Although many different methods have been employed, few studies have compared their diagnostic specificity and sensitivity. In this study, the sensitivity and specificity of three different radio allergo sorbent test (RAST) methods for quantitating specific IgE antibodies to the BPO determinant were compared. Thirty positive control sera (serum samples from penicillin allergic subjects with a positive clinical history and a positive penicillin skin test) and 30 negative control sera (sera from subjects with no history of penicillin allergy and negative skin tests) were tested for BPO-specific IgE antibodies by RAST using three different conjugates coupled to the solid phase: benzylpenicillin conjugated to polylysine (BPO-PLL), benzylpenicillin conjugated to human serum albumin (BPO-HSA), and benzylpenicillin conjugated to an aminospacer (BPO-SP). Receiver operator control curves (ROC analysis) were carried out by determining different cut-off points between positive and negative values. Contingence tables were constructed and sensitivity, specificity, negative predictive values (PV-), and positive predictive values (PV+) were calculated. Pearson correlation coefficients (r) and intraclass correlation coefficients (ICC) were determined and the differences between methods were compared by chi 2 analysis. Analysis of the areas defined by the ROC curves showed statistical differences among the three methods. When cut-off points for optimal sensitivity and specificity were chosen, the BPO-HSA assay was less sensitive and less specific and had a lower PV- and PV+ than the BPO-PLL and BPO-SP assays. Assessment of r and ICC indicated that the correlation was very high, but the concordance between the PLL and SP methods was higher than between the PLL and HSA or SP and HSA methods. We conclude that for quantitating Ig

  11. A rule based method for context sensitive threshold segmentation in SPECT using simulation

    International Nuclear Information System (INIS)

    Fleming, John S.; Alaamer, Abdulaziz S.

    1998-01-01

    Robust techniques for automatic or semi-automatic segmentation of objects in single photon emission computed tomography (SPECT) are still the subject of development. This paper describes a threshold based method which uses empirical rules derived from analysis of computer simulated images of a large number of objects. The use of simulation allowed the factors affecting the threshold which correctly segmented objects to be investigated systematically. Rules could then be derived from these data to define the threshold in any particular context. The technique operated iteratively and calculated local context sensitive thresholds along radial profiles from the centre of gravity of the object. It was evaluated in a further series of simulated objects and in human studies, and compared to the use of a global fixed threshold. The method was capable of improving accuracy of segmentation and volume assessment compared to the global threshold technique. The improvements were greater for small volumes, shapes with large surface area to volume ratio, variable surrounding activity and non-uniform distributions. The method was applied successfully to simulated objects and human studies and is considered to be a significant advance on global fixed threshold techniques. (author)

  12. Sensitivity analysis approaches applied to systems biology models.

    Science.gov (United States)

    Zi, Z

    2011-11-01

    With the rising application of systems biology, sensitivity analysis methods have been widely applied to study the biological systems, including metabolic networks, signalling pathways and genetic circuits. Sensitivity analysis can provide valuable insights about how robust the biological responses are with respect to the changes of biological parameters and which model inputs are the key factors that affect the model outputs. In addition, sensitivity analysis is valuable for guiding experimental analysis, model reduction and parameter estimation. Local and global sensitivity analysis approaches are the two types of sensitivity analysis that are commonly applied in systems biology. Local sensitivity analysis is a classic method that studies the impact of small perturbations on the model outputs. On the other hand, global sensitivity analysis approaches have been applied to understand how the model outputs are affected by large variations of the model input parameters. In this review, the author introduces the basic concepts of sensitivity analysis approaches applied to systems biology models. Moreover, the author discusses the advantages and disadvantages of different sensitivity analysis methods, how to choose a proper sensitivity analysis approach, the available sensitivity analysis tools for systems biology models and the caveats in the interpretation of sensitivity analysis results.

  13. Characterization, localization and function of pertussis toxin-sensitive G proteins in the nervous systems of Aplysia and Loligo

    International Nuclear Information System (INIS)

    Vogel, S.S.

    1989-01-01

    The author has characterized pertussis toxin-sensitive G proteins in the nervous systems of the gastropod mollusc Aplysia and the cephalopod Loligo using [ 32 P]ADP-ribosylation and immunoblotting with G protein specific antisera. As in vertebrates, this class of G protein is associated with membranes and enriched in nervous tissue in Aplysia. Analysis of dissected Aplysia ganglia reveal that it is enriched in neuropil, a region containing most of the central nervous system synapses. Because both Aplysia and Loligo synaptosomes are enriched in pertussis toxin-sensitive G proteins, it is likely that they are found in synaptic terminals. Fractionation of Aplysia synaptosomes into membrane and vesicle fractions reveals that, although the majority of G protein is recovered in the plasma membrane fraction, a small proportion is recovered in the vesicle fraction. He shows that G proteins are on intracellular membranes by ADP-ribosylating extruded axoplasm with pertussis toxin. A plausible explanation for vesicular localization of G protein in axoplasm is that G proteins are transported to terminals on vesicles. He has shown, using ligature experiments with Aplysia connectives and temperature block experiments in the giant axon of Loligo, that G proteins move by anterograde fast axonal transport. Injection of pertussis toxin into the identified Aplysia neuron L10 blocks histamine-induced presynaptic inhibition of transmitter release. This suggests that pertussis toxin sensitive G proteins play a role in modulating transmitter release at synaptic terminals. In the giant synapse of Loligo, he presents preliminary data that demonstrates that the activation of G proteins in the presynaptic terminal results in decreased transmitter release

  14. High order depletion sensitivity analysis

    International Nuclear Information System (INIS)

    Naguib, K.; Adib, M.; Morcos, H.N.

    2002-01-01

    A high order depletion sensitivity method was applied to calculate the sensitivities of build-up of actinides in the irradiated fuel due to cross-section uncertainties. An iteration method based on Taylor series expansion was applied to construct stationary principle, from which all orders of perturbations were calculated. The irradiated EK-10 and MTR-20 fuels at their maximum burn-up of 25% and 65% respectively were considered for sensitivity analysis. The results of calculation show that, in case of EK-10 fuel (low burn-up), the first order sensitivity was found to be enough to perform an accuracy of 1%. While in case of MTR-20 (high burn-up) the fifth order was found to provide 3% accuracy. A computer code SENS was developed to provide the required calculations

  15. Applicability of the two-angle differential method to response measurement of neutron-sensitive devices at the RCNP high-energy neutron facility

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, Akihiko, E-mail: aki-masuda@aist.go.jp [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Matsumoto, Tetsuro [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Iwamoto, Yosuke [Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195 (Japan); Hagiwara, Masayuki [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Satoh, Daiki; Sato, Tatsuhiko [Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195 (Japan); Iwase, Hiroshi [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Yashima, Hiroshi [Research Reactor Institute, Kyoto University, 2-1010 Asashiro-nishi, Kumatori, Sennan, Osaka 590-0494 (Japan); Nakane, Yoshihiro [Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195 (Japan); Nishiyama, Jun [Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro, Tokyo 152-8550 (Japan); Shima, Tatsushi; Tamii, Atsushi; Hatanaka, Kichiji [Research Center for Nuclear Physics (RCNP), Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Harano, Hideki [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Nakamura, Takashi [Cyclotron and Radioisotope Center (CYRIC), Tohoku University, 6-3 Aramaki, Aoba, Sendai, Miyagi 980-8578 (Japan)

    2017-03-21

    Quasi-monoenergetic high-energy neutron fields induced by {sup 7}Li(p,n) reactions are used for the response evaluation of neutron-sensitive devices. The quasi-monoenergetic high-energy field consists of high-energy monoenergetic peak neutrons and unwanted continuum neutrons down to the low-energy region. A two-angle differential method has been developed to compensate for the effect of the continuum neutrons in the response measurements. In this study, the two-angle differential method was demonstrated for Bonner sphere detectors, which are typical examples of moderator-based neutron-sensitive detectors, to investigate the method's applicability and its dependence on detector characteristics. Experiments were performed under 96–387 MeV quasi-monoenergetic high-energy neutron fields at the Research Center for Nuclear Physics (RCNP), Osaka University. The measurement results for large high-density polyethylene (HDPE) sphere detectors agreed well with Monte Carlo calculations, which verified the adequacy of the two-angle differential method. By contrast, discrepancies were observed in the results for small HDPE sphere detectors and metal-induced sphere detectors. The former indicated that detectors that are particularly sensitive to low-energy neutrons may be affected by penetrating neutrons owing to the geometrical features of the RCNP facility. The latter discrepancy could be consistently explained by a problem in the evaluated cross-section data for the metals used in the calculation. Through those discussions, the adequacy of the two-angle differential method was experimentally verified, and practical suggestions were made pertaining to this method.

  16. Simple and sensitive detection method for diprophylline using glutathione-capped CdTe quantum dots as fluorescence probes

    Energy Technology Data Exchange (ETDEWEB)

    Ying, Suyan; Cui, Shumin [College of Chemistry and Life Science, Zhejiang Normal University, Jinhua 321004 (China); Wang, Weiping, E-mail: wangwp@zjnu.edu.cn [College of Chemistry and Life Science, Zhejiang Normal University, Jinhua 321004 (China); Feng, Jiuju [College of Chemistry and Life Science, Zhejiang Normal University, Jinhua 321004 (China); Chen, Jianrong [College of Geography and Environmental Science, Zhejiang Normal University, Jinhua 321004 (China)

    2014-01-15

    A simple and sensitive method for detecting diprophylline (DPP) was developed based on the fluorescence quenching of glutathione-capped CdTe quantum dots (GSH–CdTe QDs) by using diprophylline in a KH{sub 2}PO{sub 4}–Na{sub 2}HPO{sub 4} medium. Parameters affecting the quenching efficiency, including types and pH of buffer solutions as well as temperature, reaction time, adding sequence, and interfering substances, were investigated and optimized. In optimum conditions, the calibration plot of the quenched fluorescence intensity F{sub 0}/F with a DPP concentration range of 1.67×10{sup –6} mol L{sup −1} to 1.33×10{sup –5} mol L{sup −1} was linear. The detection limit (with signal to noise ratio of 3) for DPP was 2.24×10{sup –7} mol L{sup −1}. The proposed method was successfully applied for detecting DPP in human serum. The recovery of the method was in the range of 87.41% to 117.94%. Finally, the possible quenching mechanism of GSH–CdTe QDs and DPP was also discussed. -- Highlights: • Fluorescence of GSH/CdTe QDs was quenched by diprophylline in phosphate medium. • A simple and sensitive detection method for diprophylline based on fluorescence quenching was developed. • Quenching mechanism of GSH-capped CdTe QDs with diprophylline was discussed.

  17. Robust prediction of anti-cancer drug sensitivity and sensitivity-specific biomarker.

    Directory of Open Access Journals (Sweden)

    Heewon Park

    Full Text Available The personal genomics era has attracted a large amount of attention for anti-cancer therapy by patient-specific analysis. Patient-specific analysis enables discovery of individual genomic characteristics for each patient, and thus we can effectively predict individual genetic risk of disease and perform personalized anti-cancer therapy. Although the existing methods for patient-specific analysis have successfully uncovered crucial biomarkers, their performance takes a sudden turn for the worst in the presence of outliers, since the methods are based on non-robust manners. In practice, clinical and genomic alterations datasets usually contain outliers from various sources (e.g., experiment error, coding error, etc. and the outliers may significantly affect the result of patient-specific analysis. We propose a robust methodology for patient-specific analysis in line with the NetwrokProfiler. In the proposed method, outliers in high dimensional gene expression levels and drug response datasets are simultaneously controlled by robust Mahalanobis distance in robust principal component space. Thus, we can effectively perform for predicting anti-cancer drug sensitivity and identifying sensitivity-specific biomarkers for individual patients. We observe through Monte Carlo simulations that the proposed robust method produces outstanding performances for predicting response variable in the presence of outliers. We also apply the proposed methodology to the Sanger dataset in order to uncover cancer biomarkers and predict anti-cancer drug sensitivity, and show the effectiveness of our method.

  18. Global sensitivity analysis by polynomial dimensional decomposition

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Sharif, E-mail: rahman@engineering.uiowa.ed [College of Engineering, The University of Iowa, Iowa City, IA 52242 (United States)

    2011-07-15

    This paper presents a polynomial dimensional decomposition (PDD) method for global sensitivity analysis of stochastic systems subject to independent random input following arbitrary probability distributions. The method involves Fourier-polynomial expansions of lower-variate component functions of a stochastic response by measure-consistent orthonormal polynomial bases, analytical formulae for calculating the global sensitivity indices in terms of the expansion coefficients, and dimension-reduction integration for estimating the expansion coefficients. Due to identical dimensional structures of PDD and analysis-of-variance decomposition, the proposed method facilitates simple and direct calculation of the global sensitivity indices. Numerical results of the global sensitivity indices computed for smooth systems reveal significantly higher convergence rates of the PDD approximation than those from existing methods, including polynomial chaos expansion, random balance design, state-dependent parameter, improved Sobol's method, and sampling-based methods. However, for non-smooth functions, the convergence properties of the PDD solution deteriorate to a great extent, warranting further improvements. The computational complexity of the PDD method is polynomial, as opposed to exponential, thereby alleviating the curse of dimensionality to some extent.

  19. A simple and sensitive method for L-cysteine detection based on the fluorescence intensity increment of quantum dots

    International Nuclear Information System (INIS)

    Huang Shan; Xiao Qi; Li Ran; Guan Hongliang; Liu Jing; Liu Xiaorong; He Zhike; Liu Yi

    2009-01-01

    In this contribution, a simple and sensitive method for L-cysteine detection was established based on the increment of the fluorescence intensity of mercaptoacetic acid-capped CdSe/ZnS quantum dots (QDs) in aqueous solution. Meanwhile, the fluorescence characteristics and the optimal conditions were investigated in detail. Under the optimized conditions, the linear range of QDs fluorescence intensity versus the concentration of L-cysteine was 10-800 nmol L -1 , with a correlation coefficient (R) of 0.9969 and a limit of detection (3σ black) of 3.8 nmol L -1 . The relative standard deviation (R.S.D.) for 0.5 μmol L -1 L-cysteine was 1.1% (n = 5). There was no interference to coexisting foreign substances including common ions, carbohydrates, nucleotide acids and other 19 amino acids. The proposed method possessed the advantages of simplicity, rapidity and sensitivity. Synthetic amino acid samples, medicine sample together with human urine samples were analyzed by the methodology and the results were satisfying.

  20. Highly sensitive methanol chemical sensor based on undoped silver oxide nanoparticles prepared by a solution method

    International Nuclear Information System (INIS)

    Rahman, M.M.; Khan, S.B.; Asiri, A.M.; Jamal, A.; Faisal, M.

    2012-01-01

    We have prepared silver oxide nanoparticles (NPs) by a simple solution method using reducing agents in alkaline medium. The resulting NPs were characterized by UV-vis and FT-IR spectroscopy, X-ray powder diffraction, and field-emission scanning electron microscopy. They were deposited on a glassy carbon electrode to give a sensor with a fast response towards methanol in liquid phase. The sensor also displays good sensitivity and long-term stability, and enhanced electrochemical response. The calibration plot is linear (r 2 = 0.8294) over the 0.12 mM to 0.12 M methanol concentration range. The sensitivity is ∼ 2.65 μAcm -2 mM -1 , and the detection limit is 36.0 μM (at a SNR of 3). We also discuss possible future prospective uses of this metal oxide semiconductor nanomaterial in terms of chemical sensing. (author)

  1. Dye-Sensitized Solar Cells with Anatase TiO2 Nanorods Prepared by Hydrothermal Method

    Directory of Open Access Journals (Sweden)

    Ming-Jer Jeng

    2013-01-01

    Full Text Available The hydrothermal method provides an effective reaction environment for the synthesis of nanocrystalline materials with high purity and well-controlled crystallinity. In this work, we started with various sizes of commercial TiO2 powders and used the hydrothermal method to prepare TiO2 thin films. We found that the synthesized TiO2 nanorods were thin and long when smaller TiO2 particles were used, while larger TiO2 particles produced thicker and shorter nanorods. We also found that TiO2 films prepared by TiO2 nanorods exhibited larger surface roughness than those prepared by the commercial TiO2 particles. It was found that a pure anatase phase of TiO2 nanorods can be obtained from the hydrothermal method. The dye-sensitized solar cells fabricated with TiO2 nanorods exhibited a higher solar efficiency than those fabricated with commercial TiO2 nanoparticles directly. Further, triple-layer structures of TiO2 thin films with different particle sizes were investigated to improve the solar efficiency.

  2. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment.

    Science.gov (United States)

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-08-04

    Digital PCR has developed rapidly since it was first reported in the 1990 s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products.

  3. Application of the Tikhonov regularization method to wind retrieval from scatterometer data I. Sensitivity analysis and simulation experiments

    International Nuclear Information System (INIS)

    Zhong Jian; Huang Si-Xun; Du Hua-Dong; Zhang Liang

    2011-01-01

    Scatterometer is an instrument which provides all-day and large-scale wind field information, and its application especially to wind retrieval always attracts meteorologists. Certain reasons cause large direction error, so it is important to find where the error mainly comes. Does it mainly result from the background field, the normalized radar cross-section (NRCS) or the method of wind retrieval? It is valuable to research. First, depending on SDP2.0, the simulated ‘true’ NRCS is calculated from the simulated ‘true’ wind through the geophysical model function NSCAT2. The simulated background field is configured by adding a noise to the simulated ‘true’ wind with the non-divergence constraint. Also, the simulated ‘measured’ NRCS is formed by adding a noise to the simulated ‘true’ NRCS. Then, the sensitivity experiments are taken, and the new method of regularization is used to improve the ambiguity removal with simulation experiments. The results show that the accuracy of wind retrieval is more sensitive to the noise in the background than in the measured NRCS; compared with the two-dimensional variational (2DVAR) ambiguity removal method, the accuracy of wind retrieval can be improved with the new method of Tikhonov regularization through choosing an appropriate regularization parameter, especially for the case of large error in the background. The work will provide important information and a new method for the wind retrieval with real data. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  4. Detection of anti-liver cytosol antibody type 1 (anti-LC1) by immunodiffusion, counterimmunoelectrophoresis and immunoblotting: comparison of different techniques.

    Science.gov (United States)

    Muratori, L; Cataleta, M; Muratori, P; Manotti, P; Lenzi, M; Cassani, F; Bianchi, F B

    1995-12-01

    Liver cytosol specific antibody type 1 (anti-LC1) was first described in a proportion of patients with liver/kidney microsomal antibody type 1 (anti-LKM1)-positive autoimmune hepatitis (AIH) and is routinely evaluated by immunodiffusion (ID). Using human liver cytosol as the source of antigen, we have used ID, counterimmunoelectrophoresis (CIE) and immunoblotting (IB), to test sera from 167 patients with documented chronic liver diseases of different etiology. 15 patients had antinuclear antibody (ANA) and/or smooth muscle antibody (SMA)-positive AIH, 13 had anti-LKM1-positive AIH, four had ANA/SMA/anti-LKM1-negative AIH, 76 had anti-LKM1-positive hepatitis C (recently renamed unclassified chronic hepatitis-UCH), 40 had chronic hepatitis C, 15 had chronic hepatitis B, and 4 had chronic hepatitis D. A precipitin line of identity with an anti-LC1 reference serum was detected both by ID and CIE in 16 patients: six with anti-LKM1-positive 'definite' AIH, four with ANA/SMA/anti-LKM1-negative 'definite' AIH, and six with anti-LKM1-positive UCH. By IB, 14 out of the 16 anti-LC1-positive sera (87.5%) reacted with a 58 kDa human liver cytosolic polypeptide, whereas three out of 16 (19%) recognised an additional 60 kDa band. Compared to ID, CIE is more economical in terms of both time and reagents and provides more clear-cut results. The 58 kDa reactivity by IB was detectable in nearly all CIE/ID anti-LC1-positive patients, was not found among CIE/ID anti-LC1-negative patients. In conclusion, CIE is the ideal screening test for the detection of anti-LC1, an autoantibody that can be regarded as an additional serological marker of AIH and is especially useful in ANA/SMA/anti-LKM1 negative cases.

  5. Evaluation of a new Syphilis assay on Vitros® 5600 Integrated System

    Directory of Open Access Journals (Sweden)

    Giusy Longo

    2010-12-01

    Full Text Available Introduction. A new homogeneous immunoassay for detection of primary infection of Treponema Pallidum (TP on Vitros® 5600 Integrated System was evaluated.The scope of the study was to verify analytical performances and diagnostic accuracy in comparison to commercial methods (Immunoblotting test, ELISA test, Immunoturbidimetric test. Methods. The new Syphilis assay from SENTINEL CH. SpA, is an immunoturbidimetric assay, using microparticles coated with TP fixed on the surface of polystyrene latex particles which agglutinate by an antigen-antibody reaction when anti-TP antigen is present in the specimen. The assay was implemented on Vitros® 5600 Integrated System. Modified CLSI protocols were adopted. Acceptance criteria for total imprecision were 5% for negative samples (or SD 0.5 U/mL and 4% for positive samples. In comparison to commercial methods, sensitivity must be 99.5% and specificity 99.5%. Results. Total imprecision (22 days gave SD at 6 U/mL lower than 0.5 U/mL, and CV% at 10 U/mL and 45 U/mL lower than 4%. Low quantitation limit is 5 U/mL. No prozone up to 13000 U/mL was found. In the on-board calibration stability study no drift was found up to 4 weeks. 153 samples were tested vs immunoblotting method and specificity was 100%, sensitivity was 100%. 495 samples were tested vs ELISA method and test specificity and sensitivity were 99.6% and 100% respectively. 521 samples were tested vs immunoturbidimetric method and specificity was 99.8%, sensitivity was 100%. Interference from Bilirubin (20 mg/dL, Hemoglobin (500 mg/dL and Triglycerides (1000 mg/dL was not detected.All the sample collection tubes tested (K2EDTA, SST, LH PST II, LH, NH did not interfere with the assay. Conclusion. Performances of the new SENTINEL Syphilis assay on Vitros® 5600 Integrated System meet the requirements for its use as screening tool in blood bank, thus allowing consolidation with general chemistry on a single high volume chemistry analyzer, which is

  6. Extended forward sensitivity analysis of one-dimensional isothermal flow

    International Nuclear Information System (INIS)

    Johnson, M.; Zhao, H.

    2013-01-01

    Sensitivity analysis and uncertainty quantification is an important part of nuclear safety analysis. In this work, forward sensitivity analysis is used to compute solution sensitivities on 1-D fluid flow equations typical of those found in system level codes. Time step sensitivity analysis is included as a method for determining the accumulated error from time discretization. The ability to quantify numerical error arising from the time discretization is a unique and important feature of this method. By knowing the relative sensitivity of time step with other physical parameters, the simulation is allowed to run at optimized time steps without affecting the confidence of the physical parameter sensitivity results. The time step forward sensitivity analysis method can also replace the traditional time step convergence studies that are a key part of code verification with much less computational cost. One well-defined benchmark problem with manufactured solutions is utilized to verify the method; another test isothermal flow problem is used to demonstrate the extended forward sensitivity analysis process. Through these sample problems, the paper shows the feasibility and potential of using the forward sensitivity analysis method to quantify uncertainty in input parameters and time step size for a 1-D system-level thermal-hydraulic safety code. (authors)

  7. Utility of Western Blot Analysis for the Diagnosis of Cutaneous Leishmaniasis

    Directory of Open Access Journals (Sweden)

    Marzieh ASHRAFMANSOURI

    2015-12-01

    Full Text Available Background: Cutaneous leishmaniasis (CL is a parasitic disease with a relatively wide distribution in different areas of the world, including Iran. The parasite is mainly diagnosed microscopically, but serological approaches might be useful for diagnosis as well.  This study aimed to assess the efficacy of an immunoblotting system for serodiagnosis of cutaneous leishmaniasis in Iran.Methods: Sixty-one sera samples from parasitologically confirmed CL patients and 50 sera samples from healthy controls along with 50 sera sample from non-CL patients were collected. Native strain of Leishmania major was cultured in Schnei­der medium and soluble Leishmania antigens were prepared from amastigotes-like parasites. All of sera samples were evaluated by an immunoblot­ting system.Results: Components of 14 to 135 kDa were detectable by the sera of CL pa­tients. From 61 sera of CL patients, 59 cases (96.7% detected a 63 kDa subunit and 51 cases (83.6% recognized a 32-35 kDa component. Among all subunits, the 63 kDa band showed the highest sensitivity (96.7% and a 75 kDa band had the highest (98% specificity.Conclusion: Immunoblotting has a satisfactory performance in diagnosis of CL and this test can be used, as an aid, for proper diagnosis of CL.

  8. Methods for global sensitivity analysis in life cycle assessment

    NARCIS (Netherlands)

    Groen, Evelyne A.; Bokkers, Eddy; Heijungs, Reinout; Boer, de Imke J.M.

    2017-01-01

    Purpose: Input parameters required to quantify environmental impact in life cycle assessment (LCA) can be uncertain due to e.g. temporal variability or unknowns about the true value of emission factors. Uncertainty of environmental impact can be analysed by means of a global sensitivity analysis to

  9. Plasma levels of leptin, omentin, collagenous repeat-containing sequence of 26-kDa protein (CORS-26 and adiponectin before and after oral glucose uptake in slim adults

    Directory of Open Access Journals (Sweden)

    Schäffler Andreas

    2007-02-01

    Full Text Available Abstract Background Adipose tissue secreted proteins are collectively named adipocytokines and include leptin, adiponectin, resistin, collagenous repeat-containing sequence of 26-kDa protein (CORS-26 and omentin. Several of these adipocytokines influence insulin sensitivity and glucose metabolism and therefore systemic levels may be affected by oral glucose uptake. Whereas contradictory results have been published for leptin and adiponectin, resistin has not been extensively investigated and no reports on omentin and CORS-26 do exist. Methods Therefore the plasma levels of these proteins before and 120 min after an oral glucose load were analyzed in 20 highly-insulin sensitive, young adults by ELISA or immunoblot. Results Circulating leptin was reduced 2 h after glucose uptake whereas adiponectin and resistin levels are not changed. Distribution of adiponectin and CORS-26 isoforms were similar before and after glucose ingestion. Omentin is highly abundant in plasma and immunoblot analysis revealed no alterations when plasma levels before and 2 h after glucose intake were compared. Conclusion Taken together our data indicate that only leptin is reduced by glucose uptake in insulin-sensitive probands whereas adiponectin and resistin are not altered. CORS-26 was demonstrated for the first time to circulate as high molecular weight form in plasma and like omentin was not influenced by oral glucose load. Omentin was shown to enhance insulin-stimulated glucose uptake but systemic levels are not correlated to postprandial blood glucose.

  10. Extreme Thermal Sensitivity and Pain-Induced Sensitization in a Fibromyalgia Patient

    Directory of Open Access Journals (Sweden)

    Fong Wong

    2010-01-01

    Full Text Available During the course of a psychophysical study of fibromyalgia syndrome (FMS, one of the subjects with a long history of headache and facial pain displayed an extraordinarily severe thermal allodynia. Her stimulus-response function for ratings of cutaneous heat pain revealed a sensitivity clearly beyond that of normal controls and most FMS subjects. Specially designed psychophysical methods showed that heat sensitivity sometimes increased dramatically within a series of stimuli. Prior exposure to moderate heat pain served as a trigger for allodynic ratings of series of normally neutral thermal stimulation. These observations document a case of breakthrough pain sensitivity with implications for mechanisms of FMS pain.

  11. A highly sensitive kinetic spectrophotometric method for the determination of ascorbic Acid in pharmaceutical samples.

    Science.gov (United States)

    Shishehbore, Masoud Reza; Aghamiri, Zahra

    2014-01-01

    In this study, a new reaction system for quantitative determination of ascorbic acid was introduced. The developed method is based on inhibitory effect of ascorbic acid on the Orange G-bromate system. The change in absorbance was followed spectrophotometrically at 478 nm. The dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investigated. Under optimum experimental conditions, calibration curve was linear over the range 0.7 - 33.5 μg mL(-1) of ascorbic acid including two linear segments and the relative standard deviations (n = 6) for 5.0 and 20.0 μg mL(-1) of ascorbic acid were 1.08 and 1.02%, respectively. The limit of detection was 0.21 μg mL(-) (1) of ascorbic acid. The effect of diverse species was also investigated. The developed method was successfully applied for the determination of ascorbic acid in pharmaceutical samples. The results were in a good agreement with those of reference method.

  12. Enhanced specificity in immunoscreening of expression cDNA clones using radiolabeled antigen overlay

    International Nuclear Information System (INIS)

    Chao, S.; Chao, L.; Chao, J.

    1989-01-01

    A highly sensitive and specific method has been developed for immunoscreening clones from an expression cDNA library. The procedures utilize a radiolabeled antigen detection method described originally for the immunoblotting of plasma proteins. Screening of rat alpha 1-antitrypsin clones was used. Comparison between Western blots of alpha 1-antitrypsin using both labeled antigen and protein A detection methods showed that the former yielded lower background and greater sensitivity than the latter. Further, this technique was shown to have a lower detection limit of less than 20 ng through Western blot analysis of varying concentrations of alpha 1-antitrypsin. The procedures are based on the expression of the protein by cDNA clones containing the DNA inserts in the correct reading frame. Following the transfer of phage proteins to nitrocellulose membranes, the bivalent antibodies bind monovalently to both nitrocellulose-bound-antigen in the phage lysates and radiolabeled antigen. The radiolabeled antigen overlay method is superior to the protein A detection method in sensitivity, specificity and reproducibility. This improved method can be applied in general for screening expression cDNA libraries, provided that the specific antiserum and radiolabeled antigen are available

  13. Low-Cost and Rapid Fabrication of Metallic Nanostructures for Sensitive Biosensors Using Hot-Embossing and Dielectric-Heating Nanoimprint Methods

    Directory of Open Access Journals (Sweden)

    Kuang-Li Lee

    2017-07-01

    Full Text Available We propose two approaches—hot-embossing and dielectric-heating nanoimprinting methods—for low-cost and rapid fabrication of periodic nanostructures. Each nanofabrication process for the imprinted plastic nanostructures is completed within several seconds without the use of release agents and epoxy. Low-cost, large-area, and highly sensitive aluminum nanostructures on A4 size plastic films are fabricated by evaporating aluminum film on hot-embossing nanostructures. The narrowest bandwidth of the Fano resonance is only 2.7 nm in the visible light region. The periodic aluminum nanostructure achieves a figure of merit of 150, and an intensity sensitivity of 29,345%/RIU (refractive index unit. The rapid fabrication is also achieved by using radio-frequency (RF sensitive plastic films and a commercial RF welding machine. The dielectric-heating, using RF power, takes advantage of the rapid heating/cooling process and lower electric power consumption. The fabricated capped aluminum nanoslit array has a 5 nm Fano linewidth and 490.46 nm/RIU wavelength sensitivity. The biosensing capabilities of the metallic nanostructures are further verified by measuring antigen–antibody interactions using bovine serum albumin (BSA and anti-BSA. These rapid and high-throughput fabrication methods can benefit low-cost, highly sensitive biosensors and other sensing applications.

  14. Insulin sensitivity and albuminuria

    DEFF Research Database (Denmark)

    Pilz, Stefan; Rutters, Femke; Nijpels, Giel

    2014-01-01

    OBJECTIVE: Accumulating evidence suggests an association between insulin sensitivity and albuminuria, which, even in the normal range, is a risk factor for cardiovascular diseases. We evaluated whether insulin sensitivity is associated with albuminuria in healthy subjects. RESEARCH DESIGN...... AND METHODS: We investigated 1,415 healthy, nondiabetic participants (mean age 43.9 ± 8.3 years; 54.3% women) from the RISC (Relationship between Insulin Sensitivity and Cardiovascular Disease) study, of whom 852 participated in a follow-up examination after 3 years. At baseline, insulin sensitivity...... was assessed by hyperinsulinemic-euglycemic clamps, expressed as the M/I value. Oral glucose tolerance test-based insulin sensitivity (OGIS), homeostasis model assessment of insulin resistance (HOMA-IR), and urinary albumin-to-creatinine ratio (UACR) were determined at baseline and follow-up. RESULTS...

  15. Near-infrared responsive PbS-sensitized photovoltaic photodetectors fabricated by the spin-assisted successive ionic layer adsorption and reaction method

    International Nuclear Information System (INIS)

    Im, Sang Hyuk; Kim, Hi-jung; Seok, Sang Il

    2011-01-01

    A PbS-sensitized photovoltaic photodetector responsive to near-infrared (NIR) light was fabricated by depositing monolayered PbS nanoparticles on a mesoporous TiO 2 (mp-TiO 2 ) film via the spin-assisted successive ionic layer adsorption and reaction (SILAR) method. By adjusting the size and morphology of the PbS nanoparticles through repeated spin-assisted SILAR cycles, the PbS-sensitized photovoltaic photodetector achieved an external quantum efficiency of 9.3% at 1140 nm wavelength and could process signals up to 1 kHz.

  16. A novel method of sensitivity analysis testing by applying the DRASTIC and fuzzy optimization methods to assess groundwater vulnerability to pollution: the case of the Senegal River basin in Mali

    Science.gov (United States)

    Souleymane, Keita; Zhonghua, Tang

    2017-08-01

    Vulnerability to groundwater pollution in the Senegal River basin was studied by two different but complementary methods: the DRASTIC method (which evaluates the intrinsic vulnerability) and the fuzzy method (which assesses the specific vulnerability by taking into account the continuity of the parameters). The validation of this application has been tested by comparing the connection in groundwater and distribution of different established classes of vulnerabilities as well as the nitrate distribution in the study area. Three vulnerability classes (low, medium and high) have been identified by both the DRASTIC method and the fuzzy method (between which the normalized model was used). An integrated analysis reveals that high classes with 14.64 % (for the DRASTIC method), 21.68 % (for the normalized DRASTIC method) and 18.92 % (for the fuzzy method) are not the most dominant. In addition, a new method for sensitivity analysis was used to identify (and confirm) the main parameters which impact the vulnerability to pollution with fuzzy membership. The results showed that the vadose zone is the main parameter which impacts groundwater vulnerability to pollution while net recharge contributes least to pollution in the study area. It was also found that the fuzzy method better assesses the vulnerability to pollution with a coincidence rate of 81.13 % versus that of 77.35 % for the DRASTIC method. These results serve as a guide for policymakers to identify areas sensitive to pollution before such sites are used for socioeconomic infrastructures.

  17. Sensitivity Weaknesses in Application of some Statistical Distribution in First Order Reliability Methods

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Enevoldsen, I.

    1993-01-01

    It has been observed and shown that in some examples a sensitivity analysis of the first order reliability index results in increasing reliability index, when the standard deviation for a stochastic variable is increased while the expected value is fixed. This unfortunate behaviour can occur when...... a stochastic variable is modelled by an asymmetrical density function. For lognormally, Gumbel and Weibull distributed stochastic variables it is shown for which combinations of the/3-point, the expected value and standard deviation the weakness can occur. In relation to practical application the behaviour...... is probably rather infrequent. A simple example is shown as illustration and to exemplify that for second order reliability methods and for exact calculations of the probability of failure this behaviour is much more infrequent....

  18. A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

    Science.gov (United States)

    Wang, Zuwei; Vaksman, Zalman; Putcha, Lakshmi

    2008-01-01

    Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC

  19. Developing a Method for Resolving NOx Emission Inventory Biases Using Discrete Kalman Filter Inversion, Direct Sensitivities, and Satellite-Based Columns

    Science.gov (United States)

    An inverse method was developed to integrate satellite observations of atmospheric pollutant column concentrations and direct sensitivities predicted by a regional air quality model in order to discern biases in the emissions of the pollutant precursors.

  20. Highly sensitive detection of influenza virus in saliva by real-time PCR method using sugar chain-immobilized gold nanoparticles; application to clinical studies

    Directory of Open Access Journals (Sweden)

    Yasuo Suda

    2015-09-01

    Full Text Available A highly sensitive and convenient method for detecting influenza virus was developed using modified end-point melt curve analysis of a RT-qPCR SYBR Green method and influenza virus-binding sugar chain-immobilized gold-nanoparticles (SGNP. Because SGNPs capture influenza viruses, the virus-SGNP complex was separated easily by centrifugation. Viral RNA was detected at very low concentrations, suggesting that SGNP increased sensitivity compared with standard methods. This method was applied to clinical studies. Influenza viruses were detected in saliva of patients or inpatients who had been considered influenza-free by a rapid diagnostic assay of nasal swabs. Furthermore, the method was applied to a human trial of prophylactic anti-influenza properties of yogurt containing Lactobacillus acidophilus L-92. The incidence of influenza viruses in saliva of the L-92 group was found to be significantly lower compared to the control group. Thus, this method was useful for monitoring the course of anti-influenza treatment or preventive measures against nosocomial infection.

  1. Sensitivity and specificity of various beta-lactam antibiotics and phenotypical methods for detection of TEM, SHV and CTX-M extended-spectrum beta-lactamases.

    Science.gov (United States)

    Bedenic, B; Vranes, J; Mihaljevic, Lj; Tonkic, M; Sviben, M; Plecko, V; Kalenic, S

    2007-04-01

    The aim of this study was to compare the sensitivity and specificity of six different beta-lactam antibiotics using five phenotypical tests for detection of extended spectrum beta-lactamases (ESBLs) based on synergism of beta-lactam antibiotics and clavulanate. Experiments were performed on a set of 80 Klebsiella pneumoniae strains and 105 Escherichia coli strains with previously characterized ESBLs (SHV, TEM and CTX-M). ESBLs were detected by five different phenotypical methods: MIC (minimum inhibitory concentration) determination of beta-lactam antibiotics with and without clavulanate, double-disk synergy test (DDST), inhibitor-potentiated disk-diffusion test (IPDDT), CLSI-Clinical and Laboratory Standard Institution (former NCCLS) combined-disk-test, and modified MAST-disk-diffusion test (MAST-DD-test). Seven antibiotics were tested as indicators of ESBL production: ceftazidime, cefotaxime, ceftriaxone, aztreonam, ceftibuten, cefpodoxime and cefepime. Ceftazidime and aztreonam were the best indicators for SHV-5, SHV-12 and TEM beta-lactamases whereas cefotaxime and ceftriaxone were the most sensitive in detection of SHV-2 and CTX-M beta-lactamases in DDST, IPDDT and CLSI test. MIC determination of beta-lactam antibiotics with and without clavulanate was the most sensitive method. DDST was the least sensitive test. Double-disk synergy test, which is the most frequently used test for detection of ESBLs in routine laboratories, was the least sensitive independently of the indicator antibiotic. Since MIC determination is a very laborious and time consuming method, we would recommend the NCCLS combined disk test or IPDD test for detection of ESBLs in routine laboratories with 5 mm zone augmentation breakpoint.

  2. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Science.gov (United States)

    Arampatzis, Georgios; Katsoulakis, Markos A; Pantazis, Yannis

    2015-01-01

    Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially) sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of parameters over the

  3. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Directory of Open Access Journals (Sweden)

    Georgios Arampatzis

    Full Text Available Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of

  4. Electrophysiological measurements of spectral sensitivities: a review

    Directory of Open Access Journals (Sweden)

    R.D. DeVoe

    1997-02-01

    Full Text Available Spectral sensitivities of visual systems are specified as the reciprocals of the intensities of light (quantum fluxes needed at each wavelength to elicit the same criterion amplitude of responses. This review primarily considers the methods that have been developed for electrophysiological determinations of criterion amplitudes of slow-wave responses from single retinal cells. Traditional flash methods can require tedious dark adaptations and may yield erroneous spectral sensitivity curves which are not seen in such modifications as ramp methods. Linear response methods involve interferometry, while constant response methods involve manual or automatic adjustments of continuous illumination to keep response amplitudes constant during spectral scans. In DC or AC computerized constant response methods, feedback to determine intensities at each wavelength is derived from the response amplitudes themselves. Although all but traditional flash methods have greater or lesser abilities to provide on-line determinations of spectral sensitivities, computerized constant response methods are the most satisfactory due to flexibility, speed and maintenance of a constant adaptation level

  5. 1HNMR-Based metabolomic profiling method to develop plasma biomarkers for sensitivity to chronic heat stress in growing pigs.

    Directory of Open Access Journals (Sweden)

    Samir Dou

    Full Text Available The negative impact of heat stress (HS on the production performances in pig faming is of particular concern. Novel diagnostic methods are needed to predict the robustness of pigs to HS. Our study aimed to assess the reliability of blood metabolome to predict the sensitivity to chronic HS of 10 F1 (Large White × Creole sire families (SF reared in temperate (TEMP and in tropical (TROP regions (n = 56±5 offsprings/region/SF. Live body weight (BW and rectal temperature (RT were recorded at 23 weeks of age. Average daily feed intake (AFDI and average daily gain were calculated from weeks 11 to 23 of age, together with feed conversion ratio. Plasma blood metabolome profiles were obtained by Nuclear Magnetic Resonance spectroscopy (1HNMR from blood samples collected at week 23 in TEMP. The sensitivity to hot climatic conditions of each SF was estimated by computing a composite index of sensitivity (Isens derived from a linear combination of t statistics applied to familial BW, ADFI and RT in TEMP and TROP climates. A model of prediction of sensitivity was established with sparse Partial Least Square Discriminant Analysis (sPLS-DA between the two most robust SF (n = 102 and the two most sensitive ones (n = 121 using individual metabolomic profiles measured in TEMP. The sPLS-DA selected 29 buckets that enabled 78% of prediction accuracy by cross-validation. On the basis of this training, we predicted the proportion of sensitive pigs within the 6 remaining families (n = 337. This proportion was defined as the predicted membership of families to the sensitive category. The positive correlation between this proportion and Isens (r = 0.97, P < 0.01 suggests that plasma metabolome can be used to predict the sensitivity of pigs to hot climate.

  6. Coexistence of protease sensitive and resistant prion protein in 129VV homozygous sporadic Creutzfeldt–Jakob disease: a case report

    Directory of Open Access Journals (Sweden)

    Rodríguez-Martínez Ana B

    2012-10-01

    Full Text Available Abstract Introduction The coexistence of different molecular types of classical protease-resistant prion protein in the same individual have been described, however, the simultaneous finding of these with the recently described protease-sensitive variant or variably protease-sensitive prionopathy has, to the best of our knowledge, not yet been reported. Case presentation A 74-year-old Caucasian woman showed a sporadic Creutzfeldt–Jakob disease clinical phenotype with reactive depression, followed by cognitive impairment, akinetic-rigid Parkinsonism with pseudobulbar syndrome and gait impairment with motor apraxia, visuospatial disorientation, and evident frontal dysfunction features such as grasping, palmomental reflex and brisk perioral reflexes. She died at age 77. Neuropathological findings showed: spongiform change in the patient’s cerebral cortex, striatum, thalamus and molecular layer of the cerebellum with proteinase K-sensitive synaptic-like, dot-like or target-like prion protein deposition in the cortex, thalamus and striatum; proteinase K-resistant prion protein in the same regions; and elongated plaque-like proteinase K-resistant prion protein in the molecular layer of the cerebellum. Molecular analysis of prion protein after proteinase K digestion revealed decreased signal intensity in immunoblot, a ladder-like protein pattern, and a 71% reduction of PrPSc signal relative to non-digested material. Her cerebellum showed a 2A prion protein type largely resistant to proteinase K. Genotype of polymorphism at codon 129 was valine homozygous. Conclusion Molecular typing of prion protein along with clinical and neuropathological data revealed, to the best of our knowledge, the first case of the coexistence of different protease-sensitive prion proteins in the same patient in a rare case that did not fulfill the current clinical diagnostic criteria for either probable or possible sporadic Creutzfeldt–Jakob disease. This highlights the

  7. Enhanced Sensitivity to Detection Nanomolar Level of Cu2 + Compared to Spectrophotometry Method by Functionalized Gold Nanoparticles: Design of Sensor Assisted by Exploiting First-order Data with Chemometrics

    Science.gov (United States)

    Rasouli, Zolaikha; Ghavami, Raouf

    2018-02-01

    A simple, sensitive and efficient colorimetric assay platform for the determination of Cu2 + was proposed with the aim of developing sensitive detection based on the aggregation of AuNPs in presence of a histamine H2-receptor antagonist (famotidine, FAM) as recognition site. This study is the first to demonstrate that the molar extinction coefficients of the complexes formed by FAM and Cu2 + are very low (by analyzing the chemometrics methods on the first order data arising from different metal to ligand ratio method), leading to the undesirable sensitivity of FAM-based assays. To resolve the problem of low sensitivity, the colorimetry method based on the Cu2 +-induced aggregation of AuNPs functionalized with FAM was introduced. This procedure is accompanied by a color change from bright red to blue which can be observed with the naked eyes. Detection sensitivity obtained by the developed method increased about 100 fold compared with the spectrophotometry method. This sensor exhibited a good linear relation between the absorbance ratios at 670 to 520 nm (A670/520) and the concentration in the range 2-110 nM with LOD = 0.76 nM. The satisfactory analytical performance of the proposed sensor facilitates the development of simple and affordable UV-Vis chemosensors for environmental applications.

  8. An overview of the environmental applicability of vermicompost: from wastewater treatment to the development of sensitive analytical methods.

    Science.gov (United States)

    Pereira, Madson de Godoi; Neta, Lourdes Cardoso de Souza; Fontes, Maurício Paulo Ferreira; Souza, Adriana Nascimento; Matos, Thaionara Carvalho; Sachdev, Raquel de Lima; dos Santos, Arnaud Victor; da Guarda Souza, Marluce Oliveira; de Andrade, Marta Valéria Almeida Santana; Paulo, Gabriela Marinho Maciel; Ribeiro, Joselito Nardy; Ribeiro, Araceli Verónica Flores Nardy

    2014-01-01

    The use of vermicompost (humified material) for treating wastewaters, remediating polluted soils, improving agricultural productivity, protecting crop production, and developing sensitive analytical methods is reviewed here, covering the past 17 years. The main advantages of vermicompost, considering all applications covered in this paper, comprise (i) easy acquisition, (ii) low costs, (iii) structural, chemical, and biological characteristics responsible for exceptional adsorptive capacities as well as pollutant degradation, and (iv) the promotion of biocontrol. Specifically, for wastewater decontamination, a considerable number of works have verified the adsorption of toxic metals, but the application of vermicompost is still scarce for the retention of organic compounds. Problems related to the final disposal of enriched vermicompost (after treatment steps) are often found, in spite of some successful destinations such as organic fertilizer. For decontaminating soils, the use of vermicompost is quite scarce, mainly for inorganic pollutants. In agricultural productivity and biocontrol, vermicompost imparts remarkable benefits regarding soil aggregation, plant nutrition, and the development of beneficial microorganisms against phytopathogens. Finally, the use of vermicompost in sensitive analytical methods for quantifying toxic metals is the newest application of this adsorbent.

  9. Methylated site display (MSD)-AFLP, a sensitive and affordable method for analysis of CpG methylation profiles.

    Science.gov (United States)

    Aiba, Toshiki; Saito, Toshiyuki; Hayashi, Akiko; Sato, Shinji; Yunokawa, Harunobu; Maruyama, Toru; Fujibuchi, Wataru; Kurita, Hisaka; Tohyama, Chiharu; Ohsako, Seiichiroh

    2017-03-09

    It has been pointed out that environmental factors or chemicals can cause diseases that are developmental in origin. To detect abnormal epigenetic alterations in DNA methylation, convenient and cost-effective methods are required for such research, in which multiple samples are processed simultaneously. We here present methylated site display (MSD), a unique technique for the preparation of DNA libraries. By combining it with amplified fragment length polymorphism (AFLP) analysis, we developed a new method, MSD-AFLP. Methylated site display libraries consist of only DNAs derived from DNA fragments that are CpG methylated at the 5' end in the original genomic DNA sample. To test the effectiveness of this method, CpG methylation levels in liver, kidney, and hippocampal tissues of mice were compared to examine if MSD-AFLP can detect subtle differences in the levels of tissue-specific differentially methylated CpGs. As a result, many CpG sites suspected to be tissue-specific differentially methylated were detected. Nucleotide sequences adjacent to these methyl-CpG sites were identified and we determined the methylation level by methylation-sensitive restriction endonuclease (MSRE)-PCR analysis to confirm the accuracy of AFLP analysis. The differences of the methylation level among tissues were almost identical among these methods. By MSD-AFLP analysis, we detected many CpGs showing less than 5% statistically significant tissue-specific difference and less than 10% degree of variability. Additionally, MSD-AFLP analysis could be used to identify CpG methylation sites in other organisms including humans. MSD-AFLP analysis can potentially be used to measure slight changes in CpG methylation level. Regarding the remarkable precision, sensitivity, and throughput of MSD-AFLP analysis studies, this method will be advantageous in a variety of epigenetics-based research.

  10. Near-infrared responsive PbS-sensitized photovoltaic photodetectors fabricated by the spin-assisted successive ionic layer adsorption and reaction method

    Energy Technology Data Exchange (ETDEWEB)

    Im, Sang Hyuk; Kim, Hi-jung; Seok, Sang Il, E-mail: seoksi@krict.re.kr [KRICT-EPFL Global Research Laboratory, Advanced Materials Division, Korea Research Institute of Chemical Technology, 19 Sinseongno, Yuseong, Daejeon 305-600 (Korea, Republic of)

    2011-09-30

    A PbS-sensitized photovoltaic photodetector responsive to near-infrared (NIR) light was fabricated by depositing monolayered PbS nanoparticles on a mesoporous TiO{sub 2} (mp-TiO{sub 2}) film via the spin-assisted successive ionic layer adsorption and reaction (SILAR) method. By adjusting the size and morphology of the PbS nanoparticles through repeated spin-assisted SILAR cycles, the PbS-sensitized photovoltaic photodetector achieved an external quantum efficiency of 9.3% at 1140 nm wavelength and could process signals up to 1 kHz.

  11. Unique proteomic signature for radiation sensitive patients; a comparative study between normo-sensitive and radiation sensitive breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Skiöld, Sara [Center for Radiation Protection Research, Department of Molecular Biosciences, The Wernner-Gren Institute, Stockholm University, Stockholm (Sweden); Azimzadeh, Omid [Institute of Radiation Biology, German Research Center for Environmental Health, Helmholtz Zentrum München (Germany); Merl-Pham, Juliane [Research Unit Protein Science, German Research Center for Environmental Health, Helmholtz Zentrum München, Neuherberg (Germany); Naslund, Ingemar; Wersall, Peter; Lidbrink, Elisabet [Division of Radiotherapy, Radiumhemmet, Karolinska University Hospital, Stockholm (Sweden); Tapio, Soile [Institute of Radiation Biology, German Research Center for Environmental Health, Helmholtz Zentrum München (Germany); Harms-Ringdahl, Mats [Center for Radiation Protection Research, Department of Molecular Biosciences, The Wernner-Gren Institute, Stockholm University, Stockholm (Sweden); Haghdoost, Siamak, E-mail: Siamak.Haghdoost@su.se [Center for Radiation Protection Research, Department of Molecular Biosciences, The Wernner-Gren Institute, Stockholm University, Stockholm (Sweden)

    2015-06-15

    Highlights: • The unique protein expression profiles were found that separate radiosensitive from normal sensitive breast cancer patients. • The oxidative stress response, coagulation properties and acute phase response suggested to be the hallmarks of radiation sensitivity. - Abstract: Radiation therapy is a cornerstone of modern cancer treatment. Understanding the mechanisms behind normal tissue sensitivity is essential in order to minimize adverse side effects and yet to prevent local cancer reoccurrence. The aim of this study was to identify biomarkers of radiation sensitivity to enable personalized cancer treatment. To investigate the mechanisms behind radiation sensitivity a pilot study was made where eight radiation-sensitive and nine normo-sensitive patients were selected from a cohort of 2914 breast cancer patients, based on acute tissue reactions after radiation therapy. Whole blood was sampled and irradiated in vitro with 0, 1, or 150 mGy followed by 3 h incubation at 37 °C. The leukocytes of the two groups were isolated, pooled and protein expression profiles were investigated using isotope-coded protein labeling method (ICPL). First, leukocytes from the in vitro irradiated whole blood from normo-sensitive and extremely sensitive patients were compared to the non-irradiated controls. To validate this first study a second ICPL analysis comparing only the non-irradiated samples was conducted. Both approaches showed unique proteomic signatures separating the two groups at the basal level and after doses of 1 and 150 mGy. Pathway analyses of both proteomic approaches suggest that oxidative stress response, coagulation properties and acute phase response are hallmarks of radiation sensitivity supporting our previous study on oxidative stress response. This investigation provides unique characteristics of radiation sensitivity essential for individualized radiation therapy.

  12. Unique proteomic signature for radiation sensitive patients; a comparative study between normo-sensitive and radiation sensitive breast cancer patients

    International Nuclear Information System (INIS)

    Skiöld, Sara; Azimzadeh, Omid; Merl-Pham, Juliane; Naslund, Ingemar; Wersall, Peter; Lidbrink, Elisabet; Tapio, Soile; Harms-Ringdahl, Mats; Haghdoost, Siamak

    2015-01-01

    Highlights: • The unique protein expression profiles were found that separate radiosensitive from normal sensitive breast cancer patients. • The oxidative stress response, coagulation properties and acute phase response suggested to be the hallmarks of radiation sensitivity. - Abstract: Radiation therapy is a cornerstone of modern cancer treatment. Understanding the mechanisms behind normal tissue sensitivity is essential in order to minimize adverse side effects and yet to prevent local cancer reoccurrence. The aim of this study was to identify biomarkers of radiation sensitivity to enable personalized cancer treatment. To investigate the mechanisms behind radiation sensitivity a pilot study was made where eight radiation-sensitive and nine normo-sensitive patients were selected from a cohort of 2914 breast cancer patients, based on acute tissue reactions after radiation therapy. Whole blood was sampled and irradiated in vitro with 0, 1, or 150 mGy followed by 3 h incubation at 37 °C. The leukocytes of the two groups were isolated, pooled and protein expression profiles were investigated using isotope-coded protein labeling method (ICPL). First, leukocytes from the in vitro irradiated whole blood from normo-sensitive and extremely sensitive patients were compared to the non-irradiated controls. To validate this first study a second ICPL analysis comparing only the non-irradiated samples was conducted. Both approaches showed unique proteomic signatures separating the two groups at the basal level and after doses of 1 and 150 mGy. Pathway analyses of both proteomic approaches suggest that oxidative stress response, coagulation properties and acute phase response are hallmarks of radiation sensitivity supporting our previous study on oxidative stress response. This investigation provides unique characteristics of radiation sensitivity essential for individualized radiation therapy

  13. PCR diagnostics underestimate the prevalence of avian malaria (Plasmodium relictum) in experimentally-infected passerines

    Science.gov (United States)

    Jarvi, Susan I.; Schultz, Jeffrey J.; Atkinson, Carter T.

    2002-01-01

    Several polymerase chain reaction (PCR)-based methods have recently been developed for diagnosing malarial infections in both birds and reptiles, but a critical evaluation of their sensitivity in experimentally-infected hosts has not been done. This study compares the sensitivity of several PCR-based methods for diagnosing avian malaria (Plasmodium relictum) in captive Hawaiian honeycreepers using microscopy and a recently developed immunoblotting technique. Sequential blood samples were collected over periods of up to 4.4 yr after experimental infection and rechallenge to determine both the duration and detectability of chronic infections. Two new nested PCR approaches for detecting circulating parasites based on P. relictum 18S rRNA genes and the thrombospondin-related anonymous protein (TRAP) gene are described. The blood smear and the PCR tests were less sensitive than serological methods for detecting chronic malarial infections. Individually, none of the diagnostic methods was 100% accurate in detecting subpatent infections, although serological methods were significantly more sensitive (97%) than either nested PCR (61–84%) or microscopy (27%). Circulating parasites in chronically infected birds either disappear completely from circulation or to drop to intensities below detectability by nested PCR. Thus, the use of PCR as a sole means of detection of circulating parasites may significantly underestimate true prevalence.

  14. Sensitivity technologies for large scale simulation

    International Nuclear Information System (INIS)

    Collis, Samuel Scott; Bartlett, Roscoe Ainsworth; Smith, Thomas Michael; Heinkenschloss, Matthias; Wilcox, Lucas C.; Hill, Judith C.; Ghattas, Omar; Berggren, Martin Olof; Akcelik, Volkan; Ober, Curtis Curry; van Bloemen Waanders, Bart Gustaaf; Keiter, Eric Richard

    2005-01-01

    Sensitivity analysis is critically important to numerous analysis algorithms, including large scale optimization, uncertainty quantification,reduced order modeling, and error estimation. Our research focused on developing tools, algorithms and standard interfaces to facilitate the implementation of sensitivity type analysis into existing code and equally important, the work was focused on ways to increase the visibility of sensitivity analysis. We attempt to accomplish the first objective through the development of hybrid automatic differentiation tools, standard linear algebra interfaces for numerical algorithms, time domain decomposition algorithms and two level Newton methods. We attempt to accomplish the second goal by presenting the results of several case studies in which direct sensitivities and adjoint methods have been effectively applied, in addition to an investigation of h-p adaptivity using adjoint based a posteriori error estimation. A mathematical overview is provided of direct sensitivities and adjoint methods for both steady state and transient simulations. Two case studies are presented to demonstrate the utility of these methods. A direct sensitivity method is implemented to solve a source inversion problem for steady state internal flows subject to convection diffusion. Real time performance is achieved using novel decomposition into offline and online calculations. Adjoint methods are used to reconstruct initial conditions of a contamination event in an external flow. We demonstrate an adjoint based transient solution. In addition, we investigated time domain decomposition algorithms in an attempt to improve the efficiency of transient simulations. Because derivative calculations are at the root of sensitivity calculations, we have developed hybrid automatic differentiation methods and implemented this approach for shape optimization for gas dynamics using the Euler equations. The hybrid automatic differentiation method was applied to a first

  15. In chemico skin sensitization risk assessment of botanical ingredients.

    Science.gov (United States)

    Avonto, Cristina; Chittiboyina, Amar G; Sadrieh, Nakissa; Vukmanovic, Stanislav; Khan, Ikhlas A

    2018-03-24

    Skin sensitization risk assessment of botanical ingredients is necessary for consumers' protection and occupational hazard identification. There are currently very few available alternative methods that can assist in the evaluation of complex mixtures. Chemical methods can provide essential information in a timely manner and thus help to reduce the need for in vivo testing, and they can complement and facilitate targeted in vitro assays. In the present work, the applicability of the high-throughput screening with dansyl cysteamine (DCYA) method for the systematic evaluation of skin sensitization of complex botanicals was explored. Botanical ingredients of four unrelated plant species were obtained and tested with the high-throughput fluorescence method at three concentrations. To illustrate the minimal matrix effects of the tested extracts on the developed method, the least DCYA-reactive extract (Rosa canina) was spiked with known sensitizers at different concentrations. The data obtained from the four plant extracts and the spiking experiments with known sensitizers, suggest that the high-throughput screening-DCYA method can be successfully applied for estimating the skin sensitization potential of complex botanical matrices. This is the first report of an attempt to develop a versatile in chemico method for the rapid detection of reactive skin sensitizers in complex botanical extracts, which could complement the battery of existing validated, non-animal methods. Copyright © 2018 John Wiley & Sons, Ltd.

  16. A Comparison of the Capability of Sensitivity Level 3 and Sensitivity Level 4 Fluorescent Penetrants to Detect Fatigue Cracks in Aluminum

    Science.gov (United States)

    Parker, Bradford, H.

    2009-01-01

    Historically both sensitivity level 3 and sensitivity level 4 fluorescent penetrants have been used to perform NASA Standard Level inspections of aerospace hardware. In April 2008, NASA-STD-5009 established a requirement that only sensitivity level 4 penetrants were acceptable for inspections of NASA hardware. Having NASA contractors change existing processes or perform demonstration tests to certify sensitivity level 3 penetrants posed a potentially huge cost to the Agency. This study was conducted to directly compare the probability of detection sensitivity level 3 and level 4 penetrants using both Method A and Method D inspection processes. The study results strongly support the conclusion that sensitivity level 3 penetrants are acceptable for NASA Standard Level inspections

  17. A simple, rapid and green method based on pulsed potentiostatic electrodeposition of reduced graphene oxide on glass carbon electrode for sensitive voltammetric detection of sophoridine

    International Nuclear Information System (INIS)

    Wang, Fei; Wu, Yanju; Lu, Kui; Gao, Lin; Ye, Baoxian

    2014-01-01

    Graphical abstract: A simple, rapid and green method, based on graphene nanosheets directly deposited onto a glassy carbon electrode by pulsed potentiostatic reduction of a graphene oxide colloidal solution, to build sensitive voltammetric sensor for the determination of sophoridine was presented. - Highlights: • A simple, rapid and green method to build sensitive voltammetric sensor was presented. • The proposed sensor has a high electrochemical sensitivity for determination of sophoridine. • The proposed sensor exhibited an excellent selectivity. - Abstract: A simple, rapid and green method was described for sensitive voltammetric detection of sophoridine based on graphene nanosheets directly deposited onto a glassy carbon electrode (GCE) by pulsed potentiostatic reduction of a graphene oxide (GO) colloidal solution. The resulting electrodes (PP-ERGO/GCE) were characterized by electrochemical methods and scanning electron microscopy. Moreover, the electrochemical behaviors of sophoridine at the modified electrode were investigated in detail by cyclic voltammetry (CV), chronoamperometry (CA) and chronocoulometry (CC). Compared with the bare GCE and the preparation of reduced graphene oxide (RGO) films by potentiostatic method (PM) modified GCE, PP-ERGO/GCE could intensively enhance the oxidation peak currents and decrease the overpotential of sophoridine. Under the selected conditions, the modified electrode showed a linear voltammetric response to sophoridine within the concentration range of 8.0 × 10 −7 ∼ 1.0 × 10 −4 mol L −11 , with the detection limit of 2.0 × 10 −7 mol L −1 . And, the method was also applied to detect sophoridine in spiked human urine with wonderful satisfactory

  18. Assay of Aliphatic Phthalates in Polymer Products by Sensitive Polarographic Method: Health and Environmental Issue

    Directory of Open Access Journals (Sweden)

    Munawar Saeed

    2010-06-01

    Full Text Available A faster, simpler and sensitive method was developed for determination of aliphatic phthalates using differential pulse polarography (DPP as standard technique. The choice and concentration of base electrolyte, solvent, initial potential, effect of water addition and interference by other phthalates were the main parameters to optimize for enhancement of peak current and to obtain well-defined polarogram with lower background current using 1.3 x 10-4 M di-butyl phthalate (DBP solution. Best results were obtained in the presence of tetra methyl ammonium bromide (TMAB as electrolyte in methanol solvent with initial potential, -1.4 V. A linear calibration plot was observed in the range of 3 x 10-7 – 1.6 x 10-4 M DBP solution as aliphatic phthalates with lower detection limit of 5.9 x 10-8 M and linear regression coefficient of 0.9987. The developed polarographic method was successfully applied for analysis of aliphtaic phthalates in various samples of locally available polymer products such as baby toys, nipples, teethers, infusion blood bags and shopping bags. The results of the current method were compared with those obtained by a reported method and good agreement was found between them.

  19. Fabrication of an Open Microfluidic Device for Immunoblotting.

    Science.gov (United States)

    Abdel-Sayed, Philippe; Yamauchi, Kevin A; Gerver, Rachel E; Herr, Amy E

    2017-09-19

    Given the wide adoption of polydimethylsiloxane (PDMS) for the rapid fabrication of microfluidic networks and the utility of polyacrylamide gel electrophoresis (PAGE), we develop a technique for fabrication of PAGE molecular sieving gels in PDMS microchannel networks. In developing the fabrication protocol, we trade-off constraints on materials properties of these two polymer materials: PDMS is permeable to O 2 and the presence of O 2 inhibits the polymerization of polyacrylamide. We present a fabrication method compatible with performing PAGE protein separations in a composite PDMS-glass microdevice, that toggles from an "enclosed" microchannel for PAGE and blotting to an "open" PA gel lane for immunoprobing and readout. To overcome the inhibitory effects of O 2 , we coat the PDMS channel with a 10% benzophenone solution, which quenches the inhibiting effect of O 2 when exposed to UV, resulting in a PAGE-in-PDMS device. We then characterize the PAGE separation performance. Using a ladder of small-to-mid mass proteins (Trypsin Inhibitor (TI); Ovalbumin (OVA); Bovine Serum Albumin (BSA)), we observe resolution of the markers in TI, with comparable reproducibility to glass microdevice PAGE. We show that benzophenone groups incorporated into the gel through methacrylamide can be UV-activated multiple times to photocapture protein. PDMS microchannel network is reversibly bonded to a glass slide allowing direct access to separated proteins and subsequent in situ diffusion-driven immunoprobing and total protein Sypro red staining. We see this PAGE-in-PDMS fabrication technique as expanding the application and use of microfluidic PAGE without the need for a glass microfabrication infrastructure.

  20. A novel method to reduce postoperative sensitivity after composite restoration: A triple-blinded in-vivo study

    Directory of Open Access Journals (Sweden)

    Chitra Janardhanan Vejai Vekaash

    2018-01-01

    Full Text Available Objective: To evaluate the efficacy of Zinc-carbonated hydroxyapatite in the reduction of postoperative sensitivity during composite placement. Context: Postoperative sensitivity after composite restoration still remains a major clinical challenge. Materials and Methods: Sixty class I cavities were prepared in 60 patients by the same operator with the following inclusion and exclusion criteria: The patients selected for the study were between 20–45 years with vital pulp and having remaining dentin thickness of 1mm. Previously restored, nonvital and tooth with periodical changes were excluded. Patients were randomly divided into two groups of 30 each—Group I self-etch and Group II selective-etch with Subgroup A- zinc-carbonated hydroxyapatite applied and Subgroup B- zinc-carbonated hydroxyapatite not applied. After the surface treatment, the teeth were restored with composite resin. The patients were evaluated with visual analogue scale (VAS at the end of one week and one month. Statistical Analysis: Data were analyzed using Kruskal–Wallis one-way analysis. Results: Comparing within groups, Group I self-etch mean values showed statistically significant lower values compared with Group II selective-etch (P < 0.01. Zinc-carbonated hydroxyapatite Subgroup A showed statistically significant lower values compared with Subgroup B where zinc-carbonated hydroxyapatite was not applied (P < 0.01. Conclusion: Application of zinc-carbonated hydroxyapatite showed significant reduction in postoperative sensitivity after composite placement.

  1. Gamma-index method sensitivity for gauging plan delivery accuracy of volumetric modulated arc therapy.

    Science.gov (United States)

    Park, Jong In; Park, Jong Min; Kim, Jung-In; Park, So-Yeon; Ye, Sung-Joon

    2015-12-01

    The aim of this study was to investigate the sensitivity of the gamma-index method according to various gamma criteria for volumetric modulated arc therapy (VMAT). Twenty head and neck (HN) and twenty prostate VMAT plans were retrospectively selected for this study. Both global and local 2D gamma evaluations were performed with criteria of 3%/3 mm, 2%/2 mm, 1%/2 mm and 2%/1 mm. In this study, the global and local gamma-index calculated the differences in doses relative to the maximum dose and the dose at the current measurement point, respectively. Using log files acquired during delivery, the differences in parameters at every control point between the VMAT plans and the log files were acquired. The differences in dose-volumetric parameters between reconstructed VMAT plans using the log files and the original VMAT plans were calculated. The Spearman's rank correlation coefficients (rs) were calculated between the passing rates and those differences. Considerable correlations with statistical significances were observed between global 1%/2 mm, local 1%/2 mm and local 2%/1 mm and the MLC position differences (rs = -0.712, -0.628 and -0.581). The numbers of rs values with statistical significance between the passing rates and the changes in dose-volumetric parameters were largest in global 2%/2 mm (n = 16), global 2%/1 mm (n = 15) and local 2%/1 mm (n = 13) criteria. Local gamma-index method with 2%/1 mm generally showed higher sensitivity to detect deviations between a VMAT plan and the delivery of the VMAT plan. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Screening sensitivity theory

    International Nuclear Information System (INIS)

    Oblow, E.M.; Perey, F.G.

    1984-01-01

    A comprehensive rigorous theory is developed for screening sensitivity coefficients in largescale modeling applications. The theory uses Bayesian inference and group theory to establish a probabilistic framework for solving an underdetermined system of linear equations. The underdetermined problem is directly related to statistical screening sensitivity theory as developed in recent years. Several examples of the new approach to screening are worked out in detail and comparisons are made with statistical approaches to the problem. The drawbacks of these latter methods are discussed at some length

  3. An Overview of the Environmental Applicability of Vermicompost: From Wastewater Treatment to the Development of Sensitive Analytical Methods

    OpenAIRE

    Pereira, Madson de Godoi; Cardoso de Souza Neta, Lourdes; Fontes, Maurício Paulo Ferreira; Souza, Adriana Nascimento; Carvalho Matos, Thaionara; de Lima Sachdev, Raquel; dos Santos, Arnaud Victor; Oliveira da Guarda Souza, Marluce; de Andrade, Marta Valéria Almeida Santana; Marinho Maciel Paulo, Gabriela; Ribeiro, Joselito Nardy; Verónica Flores Nardy Ribeiro, Araceli

    2014-01-01

    The use of vermicompost (humified material) for treating wastewaters, remediating polluted soils, improving agricultural productivity, protecting crop production, and developing sensitive analytical methods is reviewed here, covering the past 17 years. The main advantages of vermicompost, considering all applications covered in this paper, comprise (i) easy acquisition, (ii) low costs, (iii) structural, chemical, and biological characteristics responsible for exceptional adsorptive capacities...

  4. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    International Nuclear Information System (INIS)

    Izumi, Yoshihiro; Okazawa, Atsushi; Bamba, Takeshi; Kobayashi, Akio; Fukusaki, Eiichiro

    2009-01-01

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R 2 values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  5. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, Yoshihiro; Okazawa, Atsushi; Bamba, Takeshi; Kobayashi, Akio [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Fukusaki, Eiichiro, E-mail: fukusaki@bio.eng.osaka-u.ac.jp [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2009-08-26

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R{sup 2} values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  6. Hypoallergenic properties of donkey's milk: a preliminary study

    Directory of Open Access Journals (Sweden)

    Silvia Vincenzetti

    2014-06-01

    Full Text Available Cow's milk protein allergy (CMPA is an abnormal immunological response to cow milk proteins, which results in IgE-mediated reactions. The therapeutic strategy to respond to CMPA envisages the total elimination of milk or the administration of cow's milk substitutes. For this reason the use of milk from other mammalian species was tested. Among them, donkey's milk proved to be the best alternative in feeding infants affected by CMPA, since its chemical composition is comparable to human milk. In this work an in vitro study was performed in order to analyze the IgE reactivity to milk protein allergens from cow, donkey and goat. In particular, immunoblotting experiments using sera from milk-allergic and non-allergic adult volunteers were conducted with the aim of verifying the hypoallergenic property of donkey's milk. This study provided a preliminary evidence of the hypoallergenicity of donkey's milk when compared to bovine and goat milk. Considering the obtained results, it would be possible to develop a sensitive diagnostic method for CMPA detection, based on chromatographic and immunoblotting analysis.

  7. Continuous integration congestion cost allocation based on sensitivity

    International Nuclear Information System (INIS)

    Wu, Z.Q.; Wang, Y.N.

    2004-01-01

    Congestion cost allocation is a very important topic in congestion management. Allocation methods based on the Aumann-Shapley value use the discrete numerical integration method, which needs to solve the incremented OPF solution many times, and as such it is not suitable for practical application to large-scale systems. The optimal solution and its sensitivity change tendency during congestion removal using a DC optimal power flow (OPF) process is analysed. A simple continuous integration method based on the sensitivity is proposed for the congestion cost allocation. The proposed sensitivity analysis method needs a smaller computation time than the method based on using the quadratic method and inner point iteration. The proposed congestion cost allocation method uses a continuous integration method rather than discrete numerical integration. The method does not need to solve the incremented OPF solutions; which allows it use in large-scale systems. The method can also be used for AC OPF congestion management. (author)

  8. Wheat IgE-mediated food allergy in European patients: alpha-amylase inhibitors, lipid transfer proteins and low-molecular-weight glutenins

    DEFF Research Database (Denmark)

    Pastorello, Elide A; Farioli, Laura; Conti, Amedeo

    2007-01-01

    for sodium dodecyl sulfate-polyacrylamide gel electrophoresis/immunoblotting of the three Osborne's protein fractions (albumin/globulin, gliadins and glutenins) of raw and cooked wheat. Thermal sensitivity of wheat lipid transfer protein (LTP) was investigated by spectroscopic approaches. IgE cross...

  9. A hybrid approach for global sensitivity analysis

    International Nuclear Information System (INIS)

    Chakraborty, Souvik; Chowdhury, Rajib

    2017-01-01

    Distribution based sensitivity analysis (DSA) computes sensitivity of the input random variables with respect to the change in distribution of output response. Although DSA is widely appreciated as the best tool for sensitivity analysis, the computational issue associated with this method prohibits its use for complex structures involving costly finite element analysis. For addressing this issue, this paper presents a method that couples polynomial correlated function expansion (PCFE) with DSA. PCFE is a fully equivalent operational model which integrates the concepts of analysis of variance decomposition, extended bases and homotopy algorithm. By integrating PCFE into DSA, it is possible to considerably alleviate the computational burden. Three examples are presented to demonstrate the performance of the proposed approach for sensitivity analysis. For all the problems, proposed approach yields excellent results with significantly reduced computational effort. The results obtained, to some extent, indicate that proposed approach can be utilized for sensitivity analysis of large scale structures. - Highlights: • A hybrid approach for global sensitivity analysis is proposed. • Proposed approach integrates PCFE within distribution based sensitivity analysis. • Proposed approach is highly efficient.

  10. Highly sensitive detection of the PIK3CAH1047R mutation in colorectal cancer using a novel PCR-RFLP method

    International Nuclear Information System (INIS)

    Li, Wan-Ming; Hu, Ting-Ting; Zhou, Lin-Lin; Feng, Yi-Ming; Wang, Yun-Yi; Fang, Jin

    2016-01-01

    The PIK3CA H1047R mutation is considered to be a potential predictive biomarker for EGFR-targeted therapies. In this study, we developed a novel PCR-PFLP approach to detect the PIK3CA H1047R mutation in high effectiveness. A 126-bp fragment of PIK3CA exon-20 was amplified by PCR, digested with FspI restriction endonuclease and separated by 3 % agarose gel electrophoresis for the PCR-RFLP analysis. The mutant sequence of the PIK3CA H1047R was spiked into the corresponding wild-type sequence in decreasing ratios for sensitivity analysis. Eight-six cases of formalin-fixed paraffin-embedded colorectal cancer (CRC) specimens were subjected to PCR-RFLP to evaluate the applicability of the method. The PCR-RFLP method had a capability to detect as litter as 0.4 % of mutation, and revealed 16.3 % of the PIK3CA H1047R mutation in 86 CRC tissues, which was significantly higher than that discovered by DNA sequencing (9.3 %). A positive association between the PIK3CA H1047R mutation and the patients’ age was first found, except for the negative relationship with the degree of tumor differentiation. In addition, the highly sensitive detection of a combinatorial mutation of PIK3CA, KRAS and BRAF was achieved using individual PCR-RFLP methods. We developed a sensitive, simple and rapid approach to detect the low-abundance PIK3CA H1047R mutation in real CRC specimens, providing an effective tool for guiding cancer targeted therapy

  11. Discrimination of skin sensitizers from non-sensitizers by interleukin-1α and interleukin-6 production on cultured human keratinocytes.

    Science.gov (United States)

    Jung, Daun; Che, Jeong-Hwan; Lim, Kyung-Min; Chun, Young-Jin; Heo, Yong; Seok, Seung Hyeok

    2016-09-01

    In vitro testing methods for classifying sensitizers could be valuable alternatives to in vivo sensitization testing using animal models, such as the murine local lymph node assay (LLNA) and the guinea pig maximization test (GMT), but there remains a need for in vitro methods that are more accurate and simpler to distinguish skin sensitizers from non-sensitizers. Thus, the aim of our study was to establish an in vitro assay as a screening tool for detecting skin sensitizers using the human keratinocyte cell line, HaCaT. HaCaT cells were exposed to 16 relevant skin sensitizers and 6 skin non-sensitizers. The highest dose used was the dose causing 75% cell viability (CV75) that we determined by an MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] assay. The levels of extracellular production of interleukin-1α (IL-1α) and IL-6 were measured. The sensitivity of IL-1α was 63%, specificity was 83% and accuracy was 68%. In the case of IL-6, sensitivity: 69%, specificity: 83% and accuracy: 73%. Thus, this study suggests that measuring extracellular production of pro-inflammatory cytokines IL-1α and IL-6 by human HaCaT cells may potentially classify skin sensitizers from non-sensitizers. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Development of a highly sensitive loop-mediated isothermal amplification (LAMP) method for the detection of Loa loa.

    Science.gov (United States)

    Fernández-Soto, Pedro; Mvoulouga, Prosper Obolo; Akue, Jean Paul; Abán, Julio López; Santiago, Belén Vicente; Sánchez, Miguel Cordero; Muro, Antonio

    2014-01-01

    The filarial parasite Loa loa, the causative agent of loiasis, is endemic in Central and Western Africa infecting 3-13 million people. L. loa has been associated with fatal encephalopathic reactions in high Loa-infected individuals receiving ivermectin during mass drug administration programs for the control of onchocerciasis and lymphatic filariasis. In endemic areas, the only diagnostic method routinely used is the microscopic examination of mid-day blood samples by thick blood film. Improved methods for detection of L. loa are needed in endemic regions with limited resources, where delayed diagnosis results in high mortality. We have investigated the use of a loop-mediated isothermal amplification (LAMP) assay to facilitate rapid, inexpensive, molecular diagnosis of loiasis. Primers for LAMP were designed from a species-specific repetitive DNA sequence from L. loa retrieved from GenBank. Genomic DNA of a L. loa adult worm was used to optimize the LAMP conditions using a thermocycler or a conventional heating block. Amplification of DNA in the LAMP mixture was visually inspected for turbidity as well as addition of fluorescent dye. LAMP specificity was evaluated using DNA from other parasites; sensitivity was evaluated using DNA from L. loa 10-fold serially diluted. Simulated human blood samples spiked with DNA from L. loa were also tested for sensitivity. Upon addition of fluorescent dye, all positive reactions turned green while the negative controls remained orange under ambient light. After electrophoresis on agarose gels, a ladder of multiple bands of different sizes could be observed in positive samples. The detection limit of the assay was found to be as little as 0.5 ag of L. loa genomic DNA when using a heating block. We have designed, for the first time, a highly sensitive LAMP assay for the detection of L. loa which is potentially adaptable for field diagnosis and disease surveillance in loiasis-endemic areas.

  13. Development of the high-order decoupled direct method in three dimensions for particulate matter: enabling advanced sensitivity analysis in air quality models

    Directory of Open Access Journals (Sweden)

    W. Zhang

    2012-03-01

    Full Text Available The high-order decoupled direct method in three dimensions for particulate matter (HDDM-3D/PM has been implemented in the Community Multiscale Air Quality (CMAQ model to enable advanced sensitivity analysis. The major effort of this work is to develop high-order DDM sensitivity analysis of ISORROPIA, the inorganic aerosol module of CMAQ. A case-specific approach has been applied, and the sensitivities of activity coefficients and water content are explicitly computed. Stand-alone tests are performed for ISORROPIA by comparing the sensitivities (first- and second-order computed by HDDM and the brute force (BF approximations. Similar comparison has also been carried out for CMAQ sensitivities simulated using a week-long winter episode for a continental US domain. Second-order sensitivities of aerosol species (e.g., sulfate, nitrate, and ammonium with respect to domain-wide SO2, NOx, and NH3 emissions show agreement with BF results, yet exhibit less noise in locations where BF results are demonstrably inaccurate. Second-order sensitivity analysis elucidates poorly understood nonlinear responses of secondary inorganic aerosols to their precursors and competing species. Adding second-order sensitivity terms to the Taylor series projection of the nitrate concentrations with a 50% reduction in domain-wide NOx or SO2 emissions rates improves the prediction with statistical significance.

  14. A novel chemotherapeutic sensitivity-testing system based on collagen gel droplet embedded 3D-culture methods for hepatocellular carcinoma.

    Science.gov (United States)

    Hou, Jun; Hong, Zhixian; Feng, Fan; Chai, Yantao; Zhang, Yunkai; Jiang, Qiyu; Hu, Yan; Wu, Shunquan; Wu, Yingsong; Gao, Xunian; Chen, Qiong; Wan, Yong; Bi, Jingfeng; Zhang, Zheng

    2017-11-08

    Patients suffering from advanced stage hepatocellular carcinoma (HCC) often exhibit a poor prognosis or dismal clinical outcomes due to ineffective chemotherapy or a multi-drug resistance (MDR) process. Thus, it is urgent to develop a new chemotherapeutic sensitivity testing system for HCC treatment. The presence study investigated the potential application of a novel chemotherapeutic sensitivity-testing system based on a collagen gel droplet embedded 3D-culture system (CD-DST). Primary cells were separating from surgical resection specimens and then tested by CD-DST. To identify whether HCC cell lines or cells separating from clinical specimens contain MDR features, the cells were treated with an IC 50 (half maximal inhibitory concentration) or IC max (maximal inhibitory concentration) concentration of antitumor agents, e.g., 5-furuolouracil (5-FU), paclitaxel (PAC), cisplatin (CDDP), epirubicin (EPI), or oxaliplatin (L-OHP), and the inhibitory rates (IRs) were calculated. HepG2 cells were sensitive to 5-FU, PAC, CDDP, EPI, or L-OHP; the IC 50 value is 0.83 ± 0.45 μg/ml, 0.03 ± 0.02 μg/ml, 1.15 ± 0.75 μg/ml, 0.09 ± 0.03 μg/ml, or 1.76 ± 0.44 μg/ml, respectively. Only eight (8/26), nine (9/26), or five (5/26) patients were sensitive to the IC max concentration of CDDP, EPI, or L-OHP; whereas only three (3/26), four (4/26), or two (2/26) patients were sensitive to the IC 50 concentration of CDDP, EPI, or L-OHP. No patients were sensitive to 5-FU or PAC. The in vitro drug sensitivity exanimation revealed the MDR features of HCC and examined the sensitivity of HCC cells from clinical specimens to anti-tumor agents. CD-DST may be a useful method to predict the potential clinical benefits of anticancer agents for HCC patients.

  15. Development of Visible Light-Responsive Sensitized Photocatalysts

    Directory of Open Access Journals (Sweden)

    Donghua Pei

    2012-01-01

    Full Text Available The paper presents a review of studies about the visible-light-promoted photodegradation of the contaminants and energy conversion with sensitized photocatalysts. Herein we studied mechanism, physical properties, and synergism effect of the sensitized photocatalysts as well as the method for enhancing the photosensitized effect. According to the reported studies in the literature, inorganic sensitizers, organic dyes, and coordination metal complexes were very effective sensitizers that were studied mostly, of which organic dyes photosensitization is the most widely studied modified method. Photosensitization is an important way to extend the excitation wavelength to the visible range, and therefore sensitized photocatalysts play an important role in the development of visible light-responsive photocatalysts for future industrialized applications. This paper mainly describes the types, modification, photocatalytic performance, application, and the developments of photosensitization for environmental application.

  16. An Overview of the Environmental Applicability of Vermicompost: From Wastewater Treatment to the Development of Sensitive Analytical Methods

    Science.gov (United States)

    Pereira, Madson de Godoi; Cardoso de Souza Neta, Lourdes; Fontes, Maurício Paulo Ferreira; Souza, Adriana Nascimento; Carvalho Matos, Thaionara; de Lima Sachdev, Raquel; dos Santos, Arnaud Victor; Oliveira da Guarda Souza, Marluce; de Andrade, Marta Valéria Almeida Santana; Marinho Maciel Paulo, Gabriela; Ribeiro, Joselito Nardy; Verónica Flores Nardy Ribeiro, Araceli

    2014-01-01

    The use of vermicompost (humified material) for treating wastewaters, remediating polluted soils, improving agricultural productivity, protecting crop production, and developing sensitive analytical methods is reviewed here, covering the past 17 years. The main advantages of vermicompost, considering all applications covered in this paper, comprise (i) easy acquisition, (ii) low costs, (iii) structural, chemical, and biological characteristics responsible for exceptional adsorptive capacities as well as pollutant degradation, and (iv) the promotion of biocontrol. Specifically, for wastewater decontamination, a considerable number of works have verified the adsorption of toxic metals, but the application of vermicompost is still scarce for the retention of organic compounds. Problems related to the final disposal of enriched vermicompost (after treatment steps) are often found, in spite of some successful destinations such as organic fertilizer. For decontaminating soils, the use of vermicompost is quite scarce, mainly for inorganic pollutants. In agricultural productivity and biocontrol, vermicompost imparts remarkable benefits regarding soil aggregation, plant nutrition, and the development of beneficial microorganisms against phytopathogens. Finally, the use of vermicompost in sensitive analytical methods for quantifying toxic metals is the newest application of this adsorbent. PMID:24578668

  17. A New Approach for the Analysis of Hyperspectral Data: Theory and Sensitivity Analysis of the Moment Distance Method

    Directory of Open Access Journals (Sweden)

    Eric Ariel L. Salas

    2013-12-01

    Full Text Available We present the Moment Distance (MD method to advance spectral analysis in vegetation studies. It was developed to take advantage of the information latent in the shape of the reflectance curve that is not available from other spectral indices. Being mathematically simple but powerful, the approach does not require any curve transformation, such as smoothing or derivatives. Here, we show the formulation of the MD index (MDI and demonstrate its potential for vegetation studies. We simulated leaf and canopy reflectance samples derived from the combination of the PROSPECT and SAIL models to understand the sensitivity of the new method to leaf and canopy parameters. We observed reasonable agreements between vegetation parameters and the MDI when using the 600 to 750 nm wavelength range, and we saw stronger agreements in the narrow red-edge region 720 to 730 nm. Results suggest that the MDI is more sensitive to the Chl content, especially at higher amounts (Chl > 40 mg/cm2 compared to other indices such as NDVI, EVI, and WDRVI. Finally, we found an indirect relationship of MDI against the changes of the magnitude of the reflectance around the red trough with differing values of LAI.

  18. An Overview of the Environmental Applicability of Vermicompost: From Wastewater Treatment to the Development of Sensitive Analytical Methods

    Directory of Open Access Journals (Sweden)

    Madson de Godoi Pereira

    2014-01-01

    Full Text Available The use of vermicompost (humified material for treating wastewaters, remediating polluted soils, improving agricultural productivity, protecting crop production, and developing sensitive analytical methods is reviewed here, covering the past 17 years. The main advantages of vermicompost, considering all applications covered in this paper, comprise (i easy acquisition, (ii low costs, (iii structural, chemical, and biological characteristics responsible for exceptional adsorptive capacities as well as pollutant degradation, and (iv the promotion of biocontrol. Specifically, for wastewater decontamination, a considerable number of works have verified the adsorption of toxic metals, but the application of vermicompost is still scarce for the retention of organic compounds. Problems related to the final disposal of enriched vermicompost (after treatment steps are often found, in spite of some successful destinations such as organic fertilizer. For decontaminating soils, the use of vermicompost is quite scarce, mainly for inorganic pollutants. In agricultural productivity and biocontrol, vermicompost imparts remarkable benefits regarding soil aggregation, plant nutrition, and the development of beneficial microorganisms against phytopathogens. Finally, the use of vermicompost in sensitive analytical methods for quantifying toxic metals is the newest application of this adsorbent.

  19. A strategy of combining SILAR with solvothermal process for In2S3 sensitized quantum dot-sensitized solar cells

    Science.gov (United States)

    Yang, Peizhi; Tang, Qunwei; Ji, Chenming; Wang, Haobo

    2015-12-01

    Pursuit of an efficient strategy for quantum dot-sensitized photoanode has been a persistent objective for enhancing photovoltaic performances of quantum dot-sensitized solar cell (QDSC). We present here the fabrication of the indium sulfide (In2S3) quantum dot-sensitized titanium dioxide (TiO2) photoanode by combining successive ionic layer adsorption and reaction (SILAR) with solvothermal processes. The resultant QDSC consists of an In2S3 sensitized TiO2 photoanode, a liquid polysulfide electrolyte, and a Co0.85Se counter electrode. The optimized QDSC with photoanode prepared with the help of a SILAR method at 20 deposition cycles and solvothermal method yields a maximum power conversion efficiency of 1.39%.

  20. A novel method of selective removal of human DNA improves PCR sensitivity for detection of Salmonella Typhi in blood samples.

    Science.gov (United States)

    Zhou, Liqing; Pollard, Andrew J

    2012-07-27

    Enteric fever is a major public health problem, causing an estimated 21million new cases and 216,000 or more deaths every year. Current diagnosis of the disease is inadequate. Blood culture only identifies 45 to 70% of the cases and is time-consuming. Serological tests have very low sensitivity and specificity. Clinical samples obtained for diagnosis of enteric fever in the field generally have blood, so that even PCR-based methods, widely used for detection of other infectious diseases, are not a straightforward option in typhoid diagnosis. We developed a novel method to enrich target bacterial DNA by selective removal of human DNA from blood samples, enhancing the sensitivity of PCR tests. This method offers the possibility of improving PCR assays directly using clinical specimens for diagnosis of this globally important infectious disease. Blood samples were mixed with ox bile for selective lysis of human blood cells and the released human DNA was then digested with addition of bile resistant micrococcal nuclease. The intact Salmonella Typhi bacteria were collected from the specimen by centrifugation and the DNA extracted with QIAamp DNA mini kit. The presence of Salmonella Typhi bacteria in blood samples was detected by PCR with the fliC-d gene of Salmonella Typhi as the target. Micrococcal nuclease retained activity against human blood DNA in the presence of up to 9% ox bile. Background human DNA was dramatically removed from blood samples through the use of ox bile lysis and micrococcal nuclease for removal of mammalian DNA. Consequently target Salmonella Typhi DNA was enriched in DNA preparations and the PCR sensitivity for detection of Salmonella Typhi in spiked blood samples was enhanced by 1,000 fold. Use of a combination of selective ox-bile blood cell lysis and removal of human DNA with micrococcal nuclease significantly improves PCR sensitivity and offers a better option for improved typhoid PCR assays directly using clinical specimens in diagnosis of

  1. Estimating Sobol Sensitivity Indices Using Correlations

    Science.gov (United States)

    Sensitivity analysis is a crucial tool in the development and evaluation of complex mathematical models. Sobol's method is a variance-based global sensitivity analysis technique that has been applied to computational models to assess the relative importance of input parameters on...

  2. Time-sensitive remote sensing

    CERN Document Server

    Lippitt, Christopher; Coulter, Lloyd

    2015-01-01

    This book documents the state of the art in the use of remote sensing to address time-sensitive information requirements. Specifically, it brings together a group of authors who are both researchers and practitioners, who work toward or are currently using remote sensing to address time-sensitive information requirements with the goal of advancing the effective use of remote sensing to supply time-sensitive information. The book addresses the theoretical implications of time-sensitivity on the remote sensing process, assessments or descriptions of methods for expediting the delivery and improving the quality of information derived from remote sensing, and describes and analyzes time-sensitive remote sensing applications, with an emphasis on lessons learned. This book is intended for remote sensing scientists, practitioners (e.g., emergency responders or administrators of emergency response agencies), and students, but will also be of use to those seeking to understand the potential of remote sensing to addres...

  3. Human papillomavirus type 16 E7 oncoprotein causes a delay in repair of DNA damage

    International Nuclear Information System (INIS)

    Park, Jung Wook; Nickel, Kwangok P.; Torres, Alexandra D.; Lee, Denis; Lambert, Paul F.; Kimple, Randall J.

    2014-01-01

    Background and purpose: Patients with human papillomavirus related (HPV+) head and neck cancers (HNCs) demonstrate improved clinical outcomes compared to traditional HPV negative (HPV−) HNC patients. We have recently shown that HPV+ HNC cells are more sensitive to radiation than HPV− HNC cells. However, roles of HPV oncogenes in regulating the response of DNA damage repair remain unknown. Material and methods: Using immortalized normal oral epithelial cell lines, HPV+ HNC derived cell lines, and HPV16 E7-transgenic mice we assessed the repair of DNA damage using γ-H2AX foci, single and split dose clonogenic survival assays, and immunoblot. The ability of E7 to modulate expression of proteins associated with DNA repair pathways was assessed by immunoblot. Results: HPV16 E7 increased retention of γ-H2AX nuclear foci and significantly decreased sublethal DNA damage repair. While phospho-ATM, phospho-ATR, Ku70, and Ku80 expressions were not altered by E7, Rad51 was induced by E7. Correspondingly, HPV+ HNC cell lines showed retention of Rad51 after γ-radiation. Conclusions: Our findings provide further understanding as to how HPV16 E7 manipulates cellular DNA damage responses that may underlie its oncogenic potential and influence the altered sensitivity to radiation seen in HPV+ HNC as compared to HPV− HNC

  4. Suppression of Homologous Recombination by insulin-like growth factor-1 inhibition sensitizes cancer cells to PARP inhibitors

    International Nuclear Information System (INIS)

    Amin, Oreekha; Beauchamp, Marie-Claude; Nader, Paul Abou; Laskov, Ido; Iqbal, Sanaa; Philip, Charles-André; Yasmeen, Amber; Gotlieb, Walter H.

    2015-01-01

    Impairment of homologous recombination (HR) is found in close to 50 % of ovarian and breast cancer. Tumors with BRCA1 mutations show increased expression of the Insulin-like growth factor type 1 receptor (IGF-1R). We previously have shown that inhibition of IGF-1R results in growth inhibition and apoptosis of ovarian tumor cells. In the current study, we aimed to investigate the correlation between HR and sensitivity to IGF-1R inhibition. Further, we hypothesized that IGF-1R inhibition might sensitize HR proficient cancers to Poly ADP ribose polymerase (PARP) inhibitors. Using ovarian and breast cancer cellular models with known BRCA1 status, we evaluated their HR functionality by RAD51 foci formation assay. The 50 % lethal concentration (LC50) of Insulin-like growth factor type 1 receptor kinase inhibitor (IGF-1Rki) in these cells was assessed, and western immunoblotting was performed to determine the expression of proteins involved in the IGF-1R pathway. Moreover, IGF-1R inhibitors were added on HR proficient cell lines to assess mRNA and protein expression of RAD51 by qPCR and western blot. Also, we explored the interaction between RAD51 and Insulin receptor substance 1 (IRS-1) by immunoprecipitation. Next, combination effect of IGF-1R and PARP inhibitors was evaluated by clonogenic assay. Cells with mutated/methylated BRCA1 showed an impaired HR function, and had an overactivation of the IGF-1R pathway. These cells were more sensitive to IGF-1R inhibition compared to HR proficient cells. In addition, the IGF-IR inhibitor reduced RAD51 expression at mRNA and protein levels in HR proficient cells, and sensitized these cells to PARP inhibitor. Targeting IGF-1R might lead to improved personalized therapeutic approaches in cancer patients with HR deficiency. Targeting both PARP and IGF-1R might increase the clinical efficacy in HR deficient patients and increase the population of patients who may benefit from PARP inhibitors

  5. SENSITIVITY ANALYSIS as a methodical approach to the development of design strategies for environmentally sustainable buildings

    DEFF Research Database (Denmark)

    Hansen, Hanne Tine Ring

    . The research methodology applied in the project combines a literature study of descriptions of methodical approaches and built examples with a sensitivity analysis and a qualitative interview with two designers from a best practice example of a practice that has achieved environmentally sustainable...... architecture, such as: ecological, green, bio-climatic, sustainable, passive, low-energy and environmental architecture. This PhD project sets out to gain a better understanding of environmentally sustainable architecture and the methodical approaches applied in the development of this type of architecture...... an increase in scientific and political awareness, which has lead to an escalation in the number of research publications in the field, as well as, legislative demands for the energy consumption of buildings. The publications in the field refer to many different approaches to environmentally sustainable...

  6. In vitro method determing sensitivity of anticancer agents by incorporation of radioactive precursors

    International Nuclear Information System (INIS)

    Sakakibara, Satoshi

    1983-01-01

    A new sensitivity test of anticancer agents was developed to measure the lethal effects of cancer cells by the incorporation of radioactive precursors. The thousand cancer cells were cultured in a microplate in the presence of anticancer agents. These cells were exposed to radioactive precursors. Two or three days later, the cancer cells were harvested on a glass fiver filter by a multiple automatic cell-harvester and the incorporation of precursors was counted by a liquid scintillation counter. In this study, the in vivo results of drug testing in animal model systems were compared with drug sensitivities. Mice inoculated Ehrlich ascites cells were treated with various kinds of anticancer drugs. The development of the cells was compatible with the result of the sensitivity test. The growths of Lauson and ME-180 cells derived from human cancers implanted subcutaneously to nude mice were also well correlated with this sensitivity test. (author)

  7. A combination between the differential and the perturbation theory methods for calculating sensitivity coefficients; Uma combinacao entre os metodos diferencial e da teoria de pertubacao para o calculo dos coeficientes de sensibilidade

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Antonio Andrade

    1998-07-01

    A new method for the calculation of sensitivity coefficients is developed. The new method is a combination of two methodologies used for calculating theses coefficients, which are the differential and the generalized perturbation theory methods. The method utilizes as integral parameter the average flux in an arbitrary region of the system. Thus, the sensitivity coefficient contains only the component corresponding to the neutron flux. To obtain the new sensitivity coefficient, the derivatives of the integral parameter, {phi}, with respect to {sigma} are calculated using the perturbation method and the functional derivatives of this generic integral parameter with respect to {sigma} and {phi} are calculated using the differential method. (author)

  8. A fatigue test method for Pb(Zr,Ti)O3 thin films by using MEMS-based self-sensitive piezoelectric microcantilevers

    Science.gov (United States)

    Kobayashi, T.; Maeda, R.; Itoh, T.

    2008-11-01

    In the present study, we propose a new method for the fatigue test of lead zirconate titanate (PZT) thin films for MEMS devices by using self-sensitive piezoelectric microcantilevers developed in our previous study. We have deposited PZT thin films on SOI wafers and fabricated the microcantilevers through the MEMS microfabrication process. In the self-sensitive piezoelectric microcantilevers, the PZT thin films are separated in order to act as an actuator and a sensor. The fatigue characteristic of the PZT thin films can be evaluated by measuring the output voltage of the sensor as a function of time. When a sine wave of 20 Vpp and a dc bias of 10 V were applied to the PZT thin films for an actuator, the output voltage of the sensor fell down after 107 fatigue cycles. We have also investigated the influence of amplitude of the actuation sine wave and dc bias on the fatigue of the PZT thin films by using the proposed fatigue test method.

  9. A fatigue test method for Pb(Zr,Ti)O3 thin films by using MEMS-based self-sensitive piezoelectric microcantilevers

    International Nuclear Information System (INIS)

    Kobayashi, T; Maeda, R; Itoh, T

    2008-01-01

    In the present study, we propose a new method for the fatigue test of lead zirconate titanate (PZT) thin films for MEMS devices by using self-sensitive piezoelectric microcantilevers developed in our previous study. We have deposited PZT thin films on SOI wafers and fabricated the microcantilevers through the MEMS microfabrication process. In the self-sensitive piezoelectric microcantilevers, the PZT thin films are separated in order to act as an actuator and a sensor. The fatigue characteristic of the PZT thin films can be evaluated by measuring the output voltage of the sensor as a function of time. When a sine wave of 20 V pp and a dc bias of 10 V were applied to the PZT thin films for an actuator, the output voltage of the sensor fell down after 10 7 fatigue cycles. We have also investigated the influence of amplitude of the actuation sine wave and dc bias on the fatigue of the PZT thin films by using the proposed fatigue test method

  10. Large area two dimensional position sensitive detectors

    International Nuclear Information System (INIS)

    Sann, H.; Olmi, A.; Lynen, U.; Stelzer, H.; Gobbi, A.; Bock, R.

    1979-02-01

    After an introduction, a position-sensitive ionization chamber, a parallel-plate detector, and a multiwire position-sensitive chamber are described. Then the data acquisition and analysis methods are considered. Furthermore, the experimental methods for a multi-parameter experiment are described. Finally, the measurement of gamma-ray and neutron multiplicities and sequential fission is considered, and the results are presented. (HSI) [de

  11. Evaluation of sensitivity of modified star protocol microbiological method for beta-lactame antibiotics detection in raw cow milk

    Directory of Open Access Journals (Sweden)

    Borović Branka

    2013-01-01

    Full Text Available Antibiotic residues when present in animal tissues, through food chain, can enter human body, causing allergic reactions or facilitating the development of resistant bacterial strains. In order to determine the presence of antibiotics in animal tissues, it is appropriate to use convenient, reliable and sensitive methods. Microbiological methods applied for the detection of antibiotic residues in primary products of animal origin are based on the sensitivity of specific bacterial strains to a particular group of antibiotics. Regulatives on the amount of pesticides, metals and metalloids and other toxic substances, chemotherapeutics, anabolics and other substances which can be found in food ("Off. Gazette", No. 5/92, 11/92 - corr. and 32/02, state that milk and milk products can be used in commercial purposes only if not contain antibiotics in quantities that can be detected by reference methods. The applied method is modified STAR (Screening test for detection of antibiotics protocol, regulated by the CRL (Community Reference Laboratory Fougeres, France, in which the initial validation of the method had been carried out. In accordance with the demands of Regulative Commission EC No657/2002, the sensitivity of modified STAR protocol for beta lactam antibiotics group was examined , that is, there was carried out a contracted validation of the method, which initial validation had been performed at CRL. In a couple of series of experiments, 20 blank samples of raw cow milk originating from animals not treated by antibiotics, had been examined. By the beginning of the experiment samples were stored in a freezer at -20ºC. Samples of raw cow milk enriched by working solutions of seven beta-lactam antibiotics, in order to obtain concentrations at the level of 0.5, 1 and 1.5 MRL (Maximmum Residue Limit for each given antibiotic (Commission Regulation EC No. 37/2010. For detection of beta-lactam antibiotics, there was used Kundrat agar test with

  12. Ambient light-based optical biosensing platform with smartphone-embedded illumination sensor.

    Science.gov (United States)

    Park, Yoo Min; Han, Yong Duk; Chun, Hyeong Jin; Yoon, Hyun C

    2017-07-15

    We present a hand-held optical biosensing system utilizing a smartphone-embedded illumination sensor that is integrated with immunoblotting assay method. The smartphone-embedded illumination sensor is regarded as an alternative optical receiver that can replaces the conventional optical analysis apparatus because the illumination sensor can respond to the ambient light in a wide range of wavelengths, including visible and infrared. To demonstrate the biosensing applicability of our system employing the enzyme-mediated immunoblotting and accompanying light interference, various types of ambient light conditions including outdoor sunlight and indoor fluorescent were tested. For the immunoblotting assay, the biosensing channel generating insoluble precipitates as an end product of the enzymatic reaction is fabricated and mounted on the illumination sensor of the smartphone. The intensity of penetrating light arrives on the illumination sensor is inversely proportional to the amount of precipitates produced in the channel, and these changes are immediately analyzed and quantified via smartphone software. In this study, urinary C-terminal telopeptide fragment of type II collagen (uCTX-II), a biomarker of osteoarthritis diagnosis, was tested as a model analyte. The developed smartphone-based sensing system efficiently measured uCTX-II in the 0-5ng/mL concentration range with a high sensitivity and accuracy under various light conditions. These assay results show that the illumination sensor-based optical biosensor is suitable for point-of-care testing (POCT). Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Eliciting Information on Sensitive Matters Without Inviting ...

    Indian Academy of Sciences (India)

    Eliciting Information on Sensitive Matters. Without Inviting Respondents' ... methods based on Randomized Response tech- niques. ... while collecting data on some sensitive issues are well ..... Suppose there is an association of professionals.

  14. A novel method for assessing position-sensitive detector performance

    International Nuclear Information System (INIS)

    Clinthorne, N.H.; Rogers, W.L.; Shao, L.; Hero, A.O. III; Koral, K.F.

    1989-01-01

    A marked point process model of a position-sensitive detector is developed which includes the effects of detector efficiency, spatial response, energy response, and source statistics. The average mutual information between the incident distribution of γ rays and the detector response is derived and used as a performance index for detector optimization. A brief example is presented which uses this figure-of-merit for optimization of light guide dimensions for a modular scintillation camera

  15. Probability density adjoint for sensitivity analysis of the Mean of Chaos

    Energy Technology Data Exchange (ETDEWEB)

    Blonigan, Patrick J., E-mail: blonigan@mit.edu; Wang, Qiqi, E-mail: qiqi@mit.edu

    2014-08-01

    Sensitivity analysis, especially adjoint based sensitivity analysis, is a powerful tool for engineering design which allows for the efficient computation of sensitivities with respect to many parameters. However, these methods break down when used to compute sensitivities of long-time averaged quantities in chaotic dynamical systems. This paper presents a new method for sensitivity analysis of ergodic chaotic dynamical systems, the density adjoint method. The method involves solving the governing equations for the system's invariant measure and its adjoint on the system's attractor manifold rather than in phase-space. This new approach is derived for and demonstrated on one-dimensional chaotic maps and the three-dimensional Lorenz system. It is found that the density adjoint computes very finely detailed adjoint distributions and accurate sensitivities, but suffers from large computational costs.

  16. Sensitivity Analysis of Fire Dynamics Simulation

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter V.; Petersen, Arnkell J.

    2007-01-01

    (Morris method). The parameters considered are selected among physical parameters and program specific parameters. The influence on the calculation result as well as the CPU time is considered. It is found that the result is highly sensitive to many parameters even though the sensitivity varies...

  17. Evaluation of the skin sensitizing potency of chemicals by using the existing methods and considerations of relevance for elicitation

    DEFF Research Database (Denmark)

    Basketter, David A; Andersen, Klaus E; Liden, Carola

    2005-01-01

    be translated into practical thresholds and whether these could be set for both induction and elicitation. Examples are given for substances falling into various potency groups for skin sensitization relating to results from the local lymph node assay, the guinea pig maximization test, the Buehler method...... products, cosmetics, food and feeding stuffs, which are subject to specific community legislation. The main questions that are answered in this report are whether it would be possible to give detailed guidance on how to grade allergen potency based on the existing methods, whether such grading could...

  18. Sensitivity analysis in optimization and reliability problems

    International Nuclear Information System (INIS)

    Castillo, Enrique; Minguez, Roberto; Castillo, Carmen

    2008-01-01

    The paper starts giving the main results that allow a sensitivity analysis to be performed in a general optimization problem, including sensitivities of the objective function, the primal and the dual variables with respect to data. In particular, general results are given for non-linear programming, and closed formulas for linear programming problems are supplied. Next, the methods are applied to a collection of civil engineering reliability problems, which includes a bridge crane, a retaining wall and a composite breakwater. Finally, the sensitivity analysis formulas are extended to calculus of variations problems and a slope stability problem is used to illustrate the methods

  19. Sensitivity analysis in optimization and reliability problems

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, Enrique [Department of Applied Mathematics and Computational Sciences, University of Cantabria, Avda. Castros s/n., 39005 Santander (Spain)], E-mail: castie@unican.es; Minguez, Roberto [Department of Applied Mathematics, University of Castilla-La Mancha, 13071 Ciudad Real (Spain)], E-mail: roberto.minguez@uclm.es; Castillo, Carmen [Department of Civil Engineering, University of Castilla-La Mancha, 13071 Ciudad Real (Spain)], E-mail: mariacarmen.castillo@uclm.es

    2008-12-15

    The paper starts giving the main results that allow a sensitivity analysis to be performed in a general optimization problem, including sensitivities of the objective function, the primal and the dual variables with respect to data. In particular, general results are given for non-linear programming, and closed formulas for linear programming problems are supplied. Next, the methods are applied to a collection of civil engineering reliability problems, which includes a bridge crane, a retaining wall and a composite breakwater. Finally, the sensitivity analysis formulas are extended to calculus of variations problems and a slope stability problem is used to illustrate the methods.

  20. Glycosaminoglycan-resistant and pH-sensitive lipid-coated DNA complexes produced by detergent removal method.

    Science.gov (United States)

    Lehtinen, Julia; Hyvönen, Zanna; Subrizi, Astrid; Bunjes, Heike; Urtti, Arto

    2008-10-21

    Cationic polymers are efficient gene delivery vectors in in vitro conditions, but these carriers can fail in vivo due to interactions with extracellular polyanions, i.e. glycosaminoglycans (GAG). The aim of this study was to develop a stable gene delivery vector that is activated at the acidic endosomal pH. Cationic DNA/PEI complexes were coated by 1,2-dioleylphosphatidylethanolamine (DOPE) and cholesteryl hemisuccinate (CHEMS) (3:2 mol/mol) using two coating methods: detergent removal and mixing with liposomes prepared by ethanol injection. Only detergent removal produced lipid-coated DNA complexes that were stable against GAGs, but were membrane active at low pH towards endosome mimicking liposomes. In relation to the low cellular uptake of the coated complexes, their transfection efficacy was relatively high. PEGylation of the coated complexes increased their cellular uptake but reduced the pH-sensitivity. Detergent removal was thus a superior method for the production of stable, but acid activatable, lipid-coated DNA complexes.

  1. Staying theoretically sensitive when conducting grounded theory research.

    Science.gov (United States)

    Reay, Gudrun; Bouchal, Shelley Raffin; A Rankin, James

    2016-09-01

    Background Grounded theory (GT) is founded on the premise that underlying social patterns can be discovered and conceptualised into theories. The method and need for theoretical sensitivity are best understood in the historical context in which GT was developed. Theoretical sensitivity entails entering the field with no preconceptions, so as to remain open to the data and the emerging theory. Investigators also read literature from other fields to understand various ways to construct theories. Aim To explore the concept of theoretical sensitivity from a classical GT perspective, and discuss the ontological and epistemological foundations of GT. Discussion Difficulties in remaining theoretically sensitive throughout research are discussed and illustrated with examples. Emergence - the idea that theory and substance will emerge from the process of comparing data - and staying open to the data are emphasised. Conclusion Understanding theoretical sensitivity as an underlying guiding principle of GT helps the researcher make sense of important concepts, such as delaying the literature review, emergence and the constant comparative method (simultaneous collection, coding and analysis of data). Implications for practice Theoretical sensitivity and adherence to the GT research method allow researchers to discover theories that can bridge the gap between theory and practice.

  2. Antigenic stability of pecan [Carya illinoinensis (Wangenh.) K. Koch] proteins: effects of thermal treatments and in vitro digestion.

    Science.gov (United States)

    Venkatachalam, Mahesh; Teuber, Suzanne S; Peterson, W Rich; Roux, Kenneth H; Sathe, Shridhar K

    2006-02-22

    Rabbit polyclonal antibody-based inhibition ELISA as well as immunoblotting analyses of proteins extracted from variously processed pecans (cv. Desirable) indicate that pecan proteins are antigenically stable. Pecan antigens were more sensitive to moist heat than dry heat processing treatments. SDS-PAGE and immunoblotting analysis of the native and heat-denatured proteins that were previously subjected to in vitro simulated gastric fluid digestions indicate that stable antigenic peptides were produced. Both enzyme-to-substrate ratio and digestion time were influential in determining the stability of pecan polypeptides. The stable antigenic polypeptides may serve as useful markers in developing assays suitable for the detection of trace amounts of pecans in foods.

  3. Meat authentication: a new HPLC-MS/MS based method for the fast and sensitive detection of horse and pork in highly processed food.

    Science.gov (United States)

    von Bargen, Christoph; Brockmeyer, Jens; Humpf, Hans-Ulrich

    2014-10-01

    Fraudulent blending of food products with meat from undeclared species is a problem on a global scale, as exemplified by the European horse meat scandal in 2013. Routinely used methods such as ELISA and PCR can suffer from limited sensitivity or specificity when processed food samples are analyzed. In this study, we have developed an optimized method for the detection of horse and pork in different processed food matrices using MRM and MRM(3) detection of species-specific tryptic marker peptides. Identified marker peptides were sufficiently stable to resist thermal processing of different meat products and thus allow the sensitive and specific detection of pork or horse in processed food down to 0.24% in a beef matrix system. In addition, we were able to establish a rapid 2-min extraction protocol for the efficient protein extraction from processed food using high molar urea and thiourea buffers. Together, we present here the specific and sensitive detection of horse and pork meat in different processed food matrices using MRM-based detection of marker peptides. Notably, prefractionation of proteins using 2D-PAGE or off-gel fractionation is not necessary. The presented method is therefore easily applicable in analytical routine laboratories without dedicated proteomics background.

  4. Sensitivity analysis in life cycle assessment

    NARCIS (Netherlands)

    Groen, E.A.; Heijungs, R.; Bokkers, E.A.M.; Boer, de I.J.M.

    2014-01-01

    Life cycle assessments require many input parameters and many of these parameters are uncertain; therefore, a sensitivity analysis is an essential part of the final interpretation. The aim of this study is to compare seven sensitivity methods applied to three types of case stud-ies. Two

  5. Simple and sensitive method for the quantification of total bilirubin in human serum using 3-methyl-2-benzothiazolinone hydrazone hydrochloride as a chromogenic probe

    Science.gov (United States)

    Nagaraja, Padmarajaiah; Avinash, Krishnegowda; Shivakumar, Anantharaman; Dinesh, Rangappa; Shrestha, Ashwinee Kumar

    2010-11-01

    We here describe a new spectrophotometric method for measuring total bilirubin in serum. The method is based on the cleavage of bilirubin giving formaldehyde which further reacts with diazotized 3-methyl-2-benzothiazolinone hydrazone hydrochloride giving blue colored solution with maximum absorbance at 630 nm. Sensitivity of the developed method was compared with Jendrassik-Grof assay procedure and its applicability has been tested with human serum samples. Good correlation was attained between both methods giving slope of 0.994, intercept 0.015, and R2 = 0.997. Beers law obeyed in the range of 0.068-17.2 μM with good linearity, absorbance y = 0.044 Cbil + 0.003. Relative standard deviation was 0.006872, within day precision ranged 0.3-1.2% and day-to-day precision ranged 1-6%. Recovery of the method varied from 97 to 102%. The proposed method has higher sensitivity with less interference. The obtained product was extracted and was spectrally characterized for structural confirmation with FT-IR, 1H NMR.

  6. A specific and sensitive method for visualization of tumor necrosis factor in the murine central nervous system

    DEFF Research Database (Denmark)

    Lambertsen, K L; Drøjdahl, N; Owens, T

    2001-01-01

    -PCR and Western blot analysis on homogenates prepared from microdissected brain regions. Advantages and disadvantages of the methods are discussed with emphasis on the specificity and sensitivity of the histological procedures. Our strategy for detection of TNF mRNA and protein provides a solid basis...... for clarifying the cellular synthesis, regulation and function of TNF in the normal, injured or diseased CNS. Furthermore, the methodology can readily be applied in studies of other cytokines and growth factors in the CNS....

  7. A more sensitive, efficient and ISO 17025 validated Magnetic Capture real time PCR method for the detection of archetypal Toxoplasma gondii strains in meat.

    Science.gov (United States)

    Gisbert Algaba, Ignacio; Geerts, Manon; Jennes, Malgorzata; Coucke, Wim; Opsteegh, Marieke; Cox, Eric; Dorny, Pierre; Dierick, Katelijne; De Craeye, Stéphane

    2017-11-01

    Toxoplasma gondii is a globally prevalent, zoonotic parasite of major importance to public health. Various indirect and direct methods can be used for the diagnosis of toxoplasmosis. Whereas serological tests are useful to prove contact with the parasite has occurred, the actual presence of the parasite in the tissues of a seropositive animal is not demonstrated. For this, a bioassay is still the reference method. As an alternative, various PCR methods have been developed, but due to the limited amount of sample that can be tested, combined with a low tissue cyst density, those have proved to be insufficiently sensitive. A major improvement of the sensitivity was achieved with magnetic capture-based DNA extraction. By combining the hybridization of specific, biotinylated probes with the capture of those probes with streptavidin-coated paramagnetic beads, T. gondii DNA can selectively be "fished out" from a large volume of meat lysate. Still, several studies showed an insufficient sensitivity compared with the mouse bioassay. Here we present a method that is more sensitive (99% limit of detection: 65.4 tachyzoites per 100g of meat), economical and reliable (ISO 17025 validated) by adding a non-competitive PCR inhibition control (co-capture of cellular r18S) and making the release of the target DNA from the streptavidin-coated paramagnetic beads UV-dependent. The presented results demonstrate the potential of the modified Magnetic Capture real time PCR as a full alternative to the mouse bioassay for the screening of various types of tissues and meat, with the additional advantage of being quantitative. Copyright © 2017 Australian Society for Parasitology. Published by Elsevier Ltd. All rights reserved.

  8. Studies on mycobacterium tuberculosis sensitivity test by using the method of rapid radiometry with appendixes of clinical results

    International Nuclear Information System (INIS)

    Yang Yongqing; Jiang Yimin; Lu Wendong; Zhu Rongen

    1987-01-01

    Three standard strains of mycobacterium tuberculosis (H 37 RV-fully sensitive, SM-R1000 μg/ml, RFP-R 100 μg/ml) were tested with 10 concentration of 5 antitubercular agent, INH, SM, PAS, RFP and EB. 114 isolates of mycobacterium tuberculosis taken from patients were tested with INH, PAS, SM and RFP. They were agreed with the results of standard Lowenstein-Jensen method in 81.7%. 82% of the isolate test were completed within 5 days. The method may be used in routine clinical work. The liquid media prepared by authors do not require human serum albumin and it is less expensive and readily available

  9. Sensitivity ranking for freshwater invertebrates towards hydrocarbon contaminants.

    Science.gov (United States)

    Gerner, Nadine V; Cailleaud, Kevin; Bassères, Anne; Liess, Matthias; Beketov, Mikhail A

    2017-11-01

    Hydrocarbons have an utmost economical importance but may also cause substantial ecological impacts due to accidents or inadequate transportation and use. Currently, freshwater biomonitoring methods lack an indicator that can unequivocally reflect the impacts caused by hydrocarbons while being independent from effects of other stressors. The aim of the present study was to develop a sensitivity ranking for freshwater invertebrates towards hydrocarbon contaminants, which can be used in hydrocarbon-specific bioindicators. We employed the Relative Sensitivity method and developed the sensitivity ranking S hydrocarbons based on literature ecotoxicological data supplemented with rapid and mesocosm test results. A first validation of the sensitivity ranking based on an earlier field study has been conducted and revealed the S hydrocarbons ranking to be promising for application in sensitivity based indicators. Thus, the first results indicate that the ranking can serve as the core component of future hydrocarbon-specific and sensitivity trait based bioindicators.

  10. A new method for assessing how sensitivity and specificity of linkage studies affects estimation.

    Directory of Open Access Journals (Sweden)

    Cecilia L Moore

    Full Text Available While the importance of record linkage is widely recognised, few studies have attempted to quantify how linkage errors may have impacted on their own findings and outcomes. Even where authors of linkage studies have attempted to estimate sensitivity and specificity based on subjects with known status, the effects of false negatives and positives on event rates and estimates of effect are not often described.We present quantification of the effect of sensitivity and specificity of the linkage process on event rates and incidence, as well as the resultant effect on relative risks. Formulae to estimate the true number of events and estimated relative risk adjusted for given linkage sensitivity and specificity are then derived and applied to data from a prisoner mortality study. The implications of false positive and false negative matches are also discussed.Comparisons of the effect of sensitivity and specificity on incidence and relative risks indicate that it is more important for linkages to be highly specific than sensitive, particularly if true incidence rates are low. We would recommend that, where possible, some quantitative estimates of the sensitivity and specificity of the linkage process be performed, allowing the effect of these quantities on observed results to be assessed.

  11. Demonstration of a Sensitive Method to Measure Nuclear-Spin-Dependent Parity Violation

    Science.gov (United States)

    Altuntaş, Emine; Ammon, Jeffrey; Cahn, Sidney B.; DeMille, David

    2018-04-01

    Nuclear-spin-dependent parity violation (NSD-PV) effects in atoms and molecules arise from Z0 boson exchange between electrons and the nucleus, and from the magnetic interaction between electrons and the parity-violating nuclear anapole moment. We demonstrate measurements of NSD-PV that use an enhancement of the effect in diatomic molecules, here using the test system 138Ba 19. Our sensitivity surpasses that of any previous atomic parity violation measurement. We show that systematic errors can be suppressed to at least the level of the present statistical sensitivity. We measure the matrix element W of the NSD-PV interaction with total uncertainty δ W /(2 π )<0.7 Hz , for each of two configurations where W must have different signs. This sensitivity would be sufficient to measure NSD-PV effects of the size anticipated across a wide range of nuclei including 137Ba in 137BaF, where |W |/(2 π )≈5 Hz is expected.

  12. Procedures for Sensitive Immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Givol, D. [Department of Chemical Immunology, Weizmann Institute of Science, Rehovot (Israel)

    1970-02-15

    Sensitive immunoassay methods should be applied to small molecules of biological importance, which are non-immunogenic by themselves, such as small peptide hormones (e.g. bradykinin), plant hormones (e.g. indoleacetic acid), nucleotides and other small molecules. Methods of binding these small molecules, as haptens, to immunogenic carriers by various cross-linking agents are described (dicyclohexylcarbodiimide, tolylene-diisocyanate and glutaraldehyde), and the considerations involved in relation to the methods of binding and the specificity of the antibodies formed are discussed. Some uses of antibody bound to bromoacetyl cellulose as an immuno adsorbent convenient for assay of immunoglobulins are described. Finally, the sensitive immunoassay method of chemically modified phage is described. This includes methods of binding small molecules (such as the dinitrophenyl group, penicillin, indoleacetic acid) or proteins (such as insulin, immunoglobulins) to phages. Methods of direct chemical conjugation, or an indirect binding via anti-phage Fab, are described. The phage inactivation method by direct plating and its modifications (such as decision technique and complex inactivation) are compared with the more simple end-point titration method. The inhibition of phage inactivation has some advantages as it does not require radioactive material, or expensive radioactive counters, and avoids the need for separation between bound and unbound antigen. Hence, if developed, it could be used as an alternative to radioimmunoassay. (author)

  13. Alternative global goodness metrics and sensitivity analysis: heuristics to check the robustness of conclusions from studies comparing virtual screening methods.

    Science.gov (United States)

    Sheridan, Robert P

    2008-02-01

    We introduce two ways of testing the robustness of conclusions from studies comparing virtual screening methods: alternative "global goodness" metrics and sensitivity analysis. While the robustness tests cannot eliminate all biases in virtual screening comparisons, they are useful as a "reality check" for any given study. To illustrate this, we apply them to a set of enrichments published in McGaughey et al. (J. Chem. Inf. Model. 2007, 47, 1504-1519) where 11 target protein/ligand combinations are tested on 2D and 3D similarity methods, plus docking. The major conclusions in that paper, for instance, that ligand-based methods are better than docking methods, hold up. However, some minor conclusions, such as Glide being the best docking method, do not.

  14. Segmental analysis of amphetamines in hair using a sensitive UHPLC-MS/MS method.

    Science.gov (United States)

    Jakobsson, Gerd; Kronstrand, Robert

    2014-06-01

    A sensitive and robust ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine and 3,4-methylenedioxy methamphetamine in hair samples. Segmented hair (10 mg) was incubated in 2M sodium hydroxide (80°C, 10 min) before liquid-liquid extraction with isooctane followed by centrifugation and evaporation of the organic phase to dryness. The residue was reconstituted in methanol:formate buffer pH 3 (20:80). The total run time was 4 min and after optimization of UHPLC-MS/MS-parameters validation included selectivity, matrix effects, recovery, process efficiency, calibration model and range, lower limit of quantification, precision and bias. The calibration curve ranged from 0.02 to 12.5 ng/mg, and the recovery was between 62 and 83%. During validation the bias was less than ±7% and the imprecision was less than 5% for all analytes. In routine analysis, fortified control samples demonstrated an imprecision <13% and control samples made from authentic hair demonstrated an imprecision <26%. The method was applied to samples from a controlled study of amphetamine intake as well as forensic hair samples previously analyzed with an ultra high performance liquid chromatography time of flight mass spectrometry (UHPLC-TOF-MS) screening method. The proposed method was suitable for quantification of these drugs in forensic cases including violent crimes, autopsy cases, drug testing and re-granting of driving licences. This study also demonstrated that if hair samples are divided into several short segments, the time point for intake of a small dose of amphetamine can be estimated, which might be useful when drug facilitated crimes are investigated. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Coupling between the differential and perturbation theory methods for calculating sensitivity coefficients in nuclear transmutation problems

    International Nuclear Information System (INIS)

    Rossi, Lubianka Ferrari Russo

    2014-01-01

    The main target of this study is to introduce a new method for calculating the coefficients of sensibility through the union of differential method and generalized perturbation theory, which are the two methods generally used in reactor physics to obtain such variables. These two methods, separated, have some issues turning the sensibility coefficients calculation slower or computationally exhaustive. However, putting them together, it is possible to repair these issues and build a new equation for the coefficient of sensibility. The method introduced in this study was applied in a PWR reactor, where it was performed the sensibility analysis for the production and 239 Pu conversion rate during 120 days (1 cycle) of burnup. The computational code used for both burnup and sensibility analysis, the CINEW, was developed in this study and all the results were compared with codes widely used in reactor physics, such as CINDER and SERPENT. The new mathematical method for calculating the sensibility coefficients and the code CINEW provide good numerical agility and also good efficiency and security, once the new method, when compared with traditional ones, provide satisfactory results, even when the other methods use different mathematical approaches. The burnup analysis, performed using the code CINEW, was compared with the code CINDER, showing an acceptable variation, though CINDER presents some computational issues due to the period it was built. The originality of this study is the application of such method in problems involving temporal dependence and, not least, the elaboration of the first national code for burnup and sensitivity analysis. (author)

  16. How can we measure insulin sensitivity?

    International Nuclear Information System (INIS)

    Hovorka, R.

    1999-01-01

    Insulin resistance is common in general population and prevalent in patients with obesity and Type 2 diabetes. Insulin sensitivity, reciprocal to insulin resistance, can be measured with a variety of experimental methods ranging from the 'gold' standard glucose clamp to the simple HOMA assessment. Each method has its merit and is applicable under different circumstances. Adoption of glucose tracers in the experimental protocols and more specifically in glucose clamp and minimal model allows hepatic vs. peripheral insulin sensitivity to be discriminated and estimated separately. The objective of this review is to give an account of the minimal modelling approach and provide summary information about other measurement methods together with information about reproducibility of the most popular methods, the minimal model and the glucose clamp techniques. (author)

  17. Detection of endotoxins in radiopharmaceutical preparations. II. Comparison of the sensitivity of methods using the rabbit and the Limulus amoebocyte lysate for the detection of endotoxins

    Energy Technology Data Exchange (ETDEWEB)

    Bruneau, J; Cohen, Y; Merlin, L; Peysson, S

    1986-01-01

    The rise of the rabbit internal temperature after i.v. injection of an endotoxin solution is proportional to concentration. Gelation of Limulus amoebocyte, when in presence of an endotoxin solution, is also related to concentration. We compared the sensitivity of these two methods. With our experimental procedure, the rabbit is sensitive to a 0.40 ng/mL solution and the Limulus amoebocyte lysate to a 0.14 ng/mL solution. The rabbit sensitivity increase is related to the per kilogramme injected volume, whereas sensitivity is not related to the volume to check in the case of the lysate.

  18. Interactive Building Design Space Exploration Using Regionalized Sensitivity Analysis

    DEFF Research Database (Denmark)

    Østergård, Torben; Jensen, Rasmus Lund; Maagaard, Steffen

    2017-01-01

    simulation inputs are most important and which have negligible influence on the model output. Popular sensitivity methods include the Morris method, variance-based methods (e.g. Sobol’s), and regression methods (e.g. SRC). However, all these methods only address one output at a time, which makes it difficult...... in combination with the interactive parallel coordinate plot (PCP). The latter is an effective tool to explore stochastic simulations and to find high-performing building designs. The proposed methods help decision makers to focus their attention to the most important design parameters when exploring......Monte Carlo simulations combined with regionalized sensitivity analysis provide the means to explore a vast, multivariate design space in building design. Typically, sensitivity analysis shows how the variability of model output relates to the uncertainties in models inputs. This reveals which...

  19. Sensitivity analysis in a structural reliability context

    International Nuclear Information System (INIS)

    Lemaitre, Paul

    2014-01-01

    This thesis' subject is sensitivity analysis in a structural reliability context. The general framework is the study of a deterministic numerical model that allows to reproduce a complex physical phenomenon. The aim of a reliability study is to estimate the failure probability of the system from the numerical model and the uncertainties of the inputs. In this context, the quantification of the impact of the uncertainty of each input parameter on the output might be of interest. This step is called sensitivity analysis. Many scientific works deal with this topic but not in the reliability scope. This thesis' aim is to test existing sensitivity analysis methods, and to propose more efficient original methods. A bibliographical step on sensitivity analysis on one hand and on the estimation of small failure probabilities on the other hand is first proposed. This step raises the need to develop appropriate techniques. Two variables ranking methods are then explored. The first one proposes to make use of binary classifiers (random forests). The second one measures the departure, at each step of a subset method, between each input original density and the density given the subset reached. A more general and original methodology reflecting the impact of the input density modification on the failure probability is then explored. The proposed methods are then applied on the CWNR case, which motivates this thesis. (author)

  20. Monte Carlo evaluation of derivative-based global sensitivity measures

    International Nuclear Information System (INIS)

    Kucherenko, S.; Rodriguez-Fernandez, M.; Pantelides, C.; Shah, N.

    2009-01-01

    A novel approach for evaluation of derivative-based global sensitivity measures (DGSM) is presented. It is compared with the Morris and the Sobol' sensitivity indices methods. It is shown that there is a link between DGSM and Sobol' sensitivity indices. DGSM are very easy to implement and evaluate numerically. The computational time required for numerical evaluation of DGSM is many orders of magnitude lower than that for estimation of the Sobol' sensitivity indices. It is also lower than that for the Morris method. Efficiencies of Monte Carlo (MC) and quasi-Monte Carlo (QMC) sampling methods for calculation of DGSM are compared. It is shown that the superiority of QMC over MC depends on the problem's effective dimension, which can also be estimated using DGSM.

  1. Rapid, Simple, and Sensitive Spectrofluorimetric Method for the Estimation of Ganciclovir in Bulk and Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Garima Balwani

    2013-01-01

    Full Text Available A new, simple, rapid, sensitive, accurate, and affordable spectrofluorimetric method was developed and validated for the estimation of ganciclovir in bulk as well as in marketed formulations. The method was based on measuring the native fluorescence of ganciclovir in 0.2 M hydrochloric acid buffer of pH 1.2 at 374 nm after excitation at 257 nm. The calibration graph was found to be rectilinear in the concentration range of 0.25–2.00 μg mL−1. The limit of quantification and limit of detection were found to be 0.029 μg mL−1 and 0.010 μg mL−1, respectively. The method was fully validated for various parameters according to ICH guidelines. The results demonstrated that the procedure is accurate, precise, and reproducible (relative standard deviation <2% and can be successfully applied for the determination of ganciclovir in its commercial capsules with average percentage recovery of 101.31 ± 0.90.

  2. Sensitivity of ab Initio vs Empirical Methods in Computing Structural Effects on NMR Chemical Shifts for the Example of Peptides.

    Science.gov (United States)

    Sumowski, Chris Vanessa; Hanni, Matti; Schweizer, Sabine; Ochsenfeld, Christian

    2014-01-14

    The structural sensitivity of NMR chemical shifts as computed by quantum chemical methods is compared to a variety of empirical approaches for the example of a prototypical peptide, the 38-residue kaliotoxin KTX comprising 573 atoms. Despite the simplicity of empirical chemical shift prediction programs, the agreement with experimental results is rather good, underlining their usefulness. However, we show in our present work that they are highly insensitive to structural changes, which renders their use for validating predicted structures questionable. In contrast, quantum chemical methods show the expected high sensitivity to structural and electronic changes. This appears to be independent of the quantum chemical approach or the inclusion of solvent effects. For the latter, explicit solvent simulations with increasing number of snapshots were performed for two conformers of an eight amino acid sequence. In conclusion, the empirical approaches neither provide the expected magnitude nor the patterns of NMR chemical shifts determined by the clearly more costly ab initio methods upon structural changes. This restricts the use of empirical prediction programs in studies where peptide and protein structures are utilized for the NMR chemical shift evaluation such as in NMR refinement processes, structural model verifications, or calculations of NMR nuclear spin relaxation rates.

  3. A Simple and Sensitive Plant-Based Western Corn Rootworm Bioassay Method for Resistance Determination and Event Selection.

    Science.gov (United States)

    Wen, Zhimou; Chen, Jeng Shong

    2018-05-26

    We report here a simple and sensitive plant-based western corn rootworm, Diabrotica virgifera virgifera LeConte (Coleoptera: Chrysomelidae), bioassay method that allows for examination of multiple parameters for both plants and insects in a single experimental setup within a short duration. For plants, injury to roots can be visually examined, fresh root weight can be measured, and expression of trait protein in plant roots can be analyzed. For insects, in addition to survival, larval growth and development can be evaluated in several aspects including body weight gain, body length, and head capsule width. We demonstrated using the method that eCry3.1Ab-expressing 5307 corn was very effective against western corn rootworm by eliciting high mortality and significantly inhibiting larval growth and development. We also validated that the method allowed determination of resistance in an eCry3.1Ab-resistant western corn rootworm strain. While data presented in this paper demonstrate the usefulness of the method for selection of events of protein traits and for determination of resistance in laboratory populations, we envision that the method can be applied in much broader applications.

  4. The Assessment of Cognitive Emotion Regulation Strategies, Sensory Processing Sensitivity and Anxiety Sensitivity in Patients with Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Esmeil Soleymani

    2016-11-01

    Full Text Available Abstract Background: The purpose of this study was to compare the cognitive emotional regulation strategies, sensory processing sensitivity and anxiety sensitivity in patients with multiple sclerosis and normal people. Materials and Methods: Statistical population of this study was all of patients with multiple sclerosis that referred to M.S association of Iran in the tehran. Sample of this study was 30 individuals of patients with multiple sclerosis selected by available sampling method and were matched with 30 individuals of normal people. Two groups completed cognitive emotion regulation, high sensory processing sensitivity and anxiety sensitivity questionnaires. Data were analyzed by one-way analysis of variance and Multivariate Analysis of Variance. Results: The results indicated that there is significant difference between two groups in view of cognitive emotion regulation strategies in which the mean of scores of patients with multiple sclerosis in maladaptive strategies of self- blame, catastrophizing and other blame were more than normal people and mean of scores of them in adaptive strategies of positive refocusing, positive reappraisal and putting into perspective were less than normal people. The results also indicated that there is a significant difference between two groups in anxiety sensitivity and sensory processing sensitivity. Conclusion: The most of emotional problems in patients with multiple sclerosis can be the result of more application of maladaptive strategies of cognitive emotion regulation, high sensory processing sensitivity and high anxiety sensitivity.

  5. Time-dependent reliability sensitivity analysis of motion mechanisms

    International Nuclear Information System (INIS)

    Wei, Pengfei; Song, Jingwen; Lu, Zhenzhou; Yue, Zhufeng

    2016-01-01

    Reliability sensitivity analysis aims at identifying the source of structure/mechanism failure, and quantifying the effects of each random source or their distribution parameters on failure probability or reliability. In this paper, the time-dependent parametric reliability sensitivity (PRS) analysis as well as the global reliability sensitivity (GRS) analysis is introduced for the motion mechanisms. The PRS indices are defined as the partial derivatives of the time-dependent reliability w.r.t. the distribution parameters of each random input variable, and they quantify the effect of the small change of each distribution parameter on the time-dependent reliability. The GRS indices are defined for quantifying the individual, interaction and total contributions of the uncertainty in each random input variable to the time-dependent reliability. The envelope function method combined with the first order approximation of the motion error function is introduced for efficiently estimating the time-dependent PRS and GRS indices. Both the time-dependent PRS and GRS analysis techniques can be especially useful for reliability-based design. This significance of the proposed methods as well as the effectiveness of the envelope function method for estimating the time-dependent PRS and GRS indices are demonstrated with a four-bar mechanism and a car rack-and-pinion steering linkage. - Highlights: • Time-dependent parametric reliability sensitivity analysis is presented. • Time-dependent global reliability sensitivity analysis is presented for mechanisms. • The proposed method is especially useful for enhancing the kinematic reliability. • An envelope method is introduced for efficiently implementing the proposed methods. • The proposed method is demonstrated by two real planar mechanisms.

  6. Multivariate Models for Prediction of Human Skin Sensitization Hazard

    Science.gov (United States)

    Strickland, Judy; Zang, Qingda; Paris, Michael; Lehmann, David M.; Allen, David; Choksi, Neepa; Matheson, Joanna; Jacobs, Abigail; Casey, Warren; Kleinstreuer, Nicole

    2016-01-01

    One of ICCVAM’s top priorities is the development and evaluation of non-animal approaches to identify potential skin sensitizers. The complexity of biological events necessary to produce skin sensitization suggests that no single alternative method will replace the currently accepted animal tests. ICCVAM is evaluating an integrated approach to testing and assessment based on the adverse outcome pathway for skin sensitization that uses machine learning approaches to predict human skin sensitization hazard. We combined data from three in chemico or in vitro assays—the direct peptide reactivity assay (DPRA), human cell line activation test (h-CLAT), and KeratinoSens™ assay—six physicochemical properties, and an in silico read-across prediction of skin sensitization hazard into 12 variable groups. The variable groups were evaluated using two machine learning approaches, logistic regression (LR) and support vector machine (SVM), to predict human skin sensitization hazard. Models were trained on 72 substances and tested on an external set of 24 substances. The six models (three LR and three SVM) with the highest accuracy (92%) used: (1) DPRA, h-CLAT, and read-across; (2) DPRA, h-CLAT, read-across, and KeratinoSens; or (3) DPRA, h-CLAT, read-across, KeratinoSens, and log P. The models performed better at predicting human skin sensitization hazard than the murine local lymph node assay (accuracy = 88%), any of the alternative methods alone (accuracy = 63–79%), or test batteries combining data from the individual methods (accuracy = 75%). These results suggest that computational methods are promising tools to effectively identify potential human skin sensitizers without animal testing. PMID:27480324

  7. Sensitive method for dosing carboxylic functions of carbons and its application to the study of thermally processed carbon blacks

    International Nuclear Information System (INIS)

    Bernardin, Jacques

    1968-01-01

    This research thesis reports the development of a sensitive method for the dosing of carboxylic functions present at the surface of carbon blacks, and the use of this method to study the evolution of a carbon black during heat treatments. After a brief description of modes of fabrication of carbon blacks and of their structure, the author proposes an overview of knowledge on their oxidation and functional analysis. After having outlined that existing methods do not allow the measurement of function quantities less than ten micro-equivalent per gram of carbon, the author reports the development of a method which allows such measurements. By using this method, the author shows that carboxylic groups of a carbon black, oxidized by air or not, decompose during degassing by forming carbon dioxide, and that, reciprocally, the released carbon dioxide is exclusively produced by the decomposition of carboxylic groups [fr

  8. Application of Monte Carlo Methods to Perform Uncertainty and Sensitivity Analysis on Inverse Water-Rock Reactions with NETPATH

    Energy Technology Data Exchange (ETDEWEB)

    McGraw, David [Desert Research Inst. (DRI), Reno, NV (United States); Hershey, Ronald L. [Desert Research Inst. (DRI), Reno, NV (United States)

    2016-06-01

    Methods were developed to quantify uncertainty and sensitivity for NETPATH inverse water-rock reaction models and to calculate dissolved inorganic carbon, carbon-14 groundwater travel times. The NETPATH models calculate upgradient groundwater mixing fractions that produce the downgradient target water chemistry along with amounts of mineral phases that are either precipitated or dissolved. Carbon-14 groundwater travel times are calculated based on the upgradient source-water fractions, carbonate mineral phase changes, and isotopic fractionation. Custom scripts and statistical code were developed for this study to facilitate modifying input parameters, running the NETPATH simulations, extracting relevant output, postprocessing the results, and producing graphs and summaries. The scripts read userspecified values for each constituent’s coefficient of variation, distribution, sensitivity parameter, maximum dissolution or precipitation amounts, and number of Monte Carlo simulations. Monte Carlo methods for analysis of parametric uncertainty assign a distribution to each uncertain variable, sample from those distributions, and evaluate the ensemble output. The uncertainty in input affected the variability of outputs, namely source-water mixing, phase dissolution and precipitation amounts, and carbon-14 travel time. Although NETPATH may provide models that satisfy the constraints, it is up to the geochemist to determine whether the results are geochemically reasonable. Two example water-rock reaction models from previous geochemical reports were considered in this study. Sensitivity analysis was also conducted to evaluate the change in output caused by a small change in input, one constituent at a time. Results were standardized to allow for sensitivity comparisons across all inputs, which results in a representative value for each scenario. The approach yielded insight into the uncertainty in water-rock reactions and travel times. For example, there was little

  9. The clinical relevance of sensitization to pollen-related fruits and vegetables in unselected pollen-sensitized adults

    DEFF Research Database (Denmark)

    Osterballe, M.; Hansen, T.K.; Mørtz, Charlotte G

    2005-01-01

    BACKGROUND: Previous studies have described cross-reactivity between fresh fruits, vegetables and pollen. However, no data demonstrates the clinical relevance of sensitization to pollen-related fruits and vegetables in unselected pollen-sensitized adults with and without symptoms in the pollen...... season. OBJECTIVE: The aim of this study was to estimate the clinical relevance of sensitization to pollen-related fruits and vegetables in unselected pollen-sensitized adults and to examine the diagnostic value of skin-prick test (SPT), histamine release and specific IgE compared with the outcome...... of oral challenge. METHODS: In total, 936 unselected adults (female : male 479 : 457, median age 33.7 years) were examined for pollen sensitization and clinical cross-reactivity with pollen-related fruits and vegetables by questionnaire, SPT, histamine release, specific IgE and oral challenge. RESULTS...

  10. The sensitivity and efficacy method of PIK3CA exon 9 E545A as a high diagnostic accuracy in breast cancer

    Directory of Open Access Journals (Sweden)

    Desriani

    2018-06-01

    Full Text Available The phosphatidylinositol 3-kinases (PIK3s are lipid kinases. Mutation in the exon 9 and exon 20 determined as a predictive factor in anti-HER-2 therapy. In some countries, such as Singapore, China, and Peru, PIK3CA exon 9 E545A was reported to produce the highest rate of mutation. In this research, we developed and optimized PIK3CA exon 9 E545A detection methods with intercalating dye SYBR Green I based on the Tm Shift approach by using prepared recombinant plasmid pGEMT-easy PIK3CA exon 9 and PIK3CA exon 9 E545A. Recombinant plasmid was used due to the limited number of samples. Methods: Recombinant plasmid was prepared based on manufactured procedures, and this process was then followed by Tm prediction with Poland software, Tm Shift SYBR Green I development, and its characterization (reproducibility, repeatability, sensitivity, qPCR efficiency, and qPCR amplification, respectively. Result: A method for PIK3CA E545A detection based on TM shift SYBR Green I has been successfully developed. The melting temperature for PIK3CA exon 9 was 78.1 ± 0.1 °C, while that for PIK3CA exon E545A was 80.20 °C. The Tm of mutant was the same as that predicted using Polland Software. The reproducibility of the methods was high, with the coefficient values for inter and intra assays were below 10% with a high sensitivity at 1%, while R2 0.99 and PCR efficiency was 97.75%. Conclusion: The results presented here demonstrate that the PIK3CA exon 9 E545A detection method has a good sensitivity and efficacy assay, which proves that the method has a high diagnostic accuracy in breast cancer. Keywords: SYBR Green I, PIK3CA E545A, Breast cancer, Real time PCR, Recombinant plasmid

  11. GI-SVM: A sensitive method for predicting genomic islands based on unannotated sequence of a single genome.

    Science.gov (United States)

    Lu, Bingxin; Leong, Hon Wai

    2016-02-01

    Genomic islands (GIs) are clusters of functionally related genes acquired by lateral genetic transfer (LGT), and they are present in many bacterial genomes. GIs are extremely important for bacterial research, because they not only promote genome evolution but also contain genes that enhance adaption and enable antibiotic resistance. Many methods have been proposed to predict GI. But most of them rely on either annotations or comparisons with other closely related genomes. Hence these methods cannot be easily applied to new genomes. As the number of newly sequenced bacterial genomes rapidly increases, there is a need for methods to detect GI based solely on sequences of a single genome. In this paper, we propose a novel method, GI-SVM, to predict GIs given only the unannotated genome sequence. GI-SVM is based on one-class support vector machine (SVM), utilizing composition bias in terms of k-mer content. From our evaluations on three real genomes, GI-SVM can achieve higher recall compared with current methods, without much loss of precision. Besides, GI-SVM allows flexible parameter tuning to get optimal results for each genome. In short, GI-SVM provides a more sensitive method for researchers interested in a first-pass detection of GI in newly sequenced genomes.

  12. Sensitization of gastric cancer cells to alkylating agents by glaucocalyxin B via cell cycle arrest and enhanced cell death.

    Science.gov (United States)

    Ur Rahman, Muhammad Saif; Zhang, Ling; Wu, Lingyan; Xie, Yuqiong; Li, Chunchun; Cao, Jiang

    2017-01-01

    Severe side effects are major problems with chemotherapy of gastric cancer (GC). These side effects can be reduced by using sensitizing agents in combination with therapeutic drugs. In this study, the low/nontoxic dosage of glaucocalyxin B (GLB) was used with other DNA linker agents mitomycin C (MMC), cisplatin (DDP), or cyclophosphamide (CTX) to treat GC cells. Combined effectiveness of GLB with drugs was determined by proliferation assay. The molecular mechanisms associated with cell proliferation, migration, invasion, cell cycle, DNA repair/replication, apoptosis, and autophagy were investigated by immunoblotting for key proteins involved. Cell cycle and apoptosis analysis were performed by flow cytometry. Reactive oxygen species level was also examined for identification of its role in apoptosis. Proliferation assay revealed that the addition of 5 µM GLB significantly sensitizes gastric cancer SGC-7901 cells to MMC, DDP, and CTX by decreasing half-maximal inhibitory concentration (IC 50 ) by up to 75.40%±5%, 45.10%±5%, and 52.10%±5%, respectively. GLB + drugs decreased the expression level of proteins involved in proliferation and migration, suggesting the anticancer potential of GLB + drugs. GLB + MMC, GLB + CTX, and GLB + DDP arrest the cells in G 0 /G 1 and G 1 /S phase, respectively, which may be the consequence of significant decrease in the level of enzymes responsible for DNA replication and telomerase shortening. Combined use of GLB with these drugs also induces DNA damage and apoptosis by activating caspase/PARP pathways and increased production of reactive oxygen species and increased autophagy in GC cells. GLB dosage sensitizes GC cells to the alkylating agents via arresting the cell cycle and enhancing cell death. This is of significant therapeutic importance in the reduction of side effects associated with these drugs.

  13. Sensitivity analysis techniques applied to a system of hyperbolic conservation laws

    International Nuclear Information System (INIS)

    Weirs, V. Gregory; Kamm, James R.; Swiler, Laura P.; Tarantola, Stefano; Ratto, Marco; Adams, Brian M.; Rider, William J.; Eldred, Michael S.

    2012-01-01

    Sensitivity analysis is comprised of techniques to quantify the effects of the input variables on a set of outputs. In particular, sensitivity indices can be used to infer which input parameters most significantly affect the results of a computational model. With continually increasing computing power, sensitivity analysis has become an important technique by which to understand the behavior of large-scale computer simulations. Many sensitivity analysis methods rely on sampling from distributions of the inputs. Such sampling-based methods can be computationally expensive, requiring many evaluations of the simulation; in this case, the Sobol' method provides an easy and accurate way to compute variance-based measures, provided a sufficient number of model evaluations are available. As an alternative, meta-modeling approaches have been devised to approximate the response surface and estimate various measures of sensitivity. In this work, we consider a variety of sensitivity analysis methods, including different sampling strategies, different meta-models, and different ways of evaluating variance-based sensitivity indices. The problem we consider is the 1-D Riemann problem. By a careful choice of inputs, discontinuous solutions are obtained, leading to discontinuous response surfaces; such surfaces can be particularly problematic for meta-modeling approaches. The goal of this study is to compare the estimated sensitivity indices with exact values and to evaluate the convergence of these estimates with increasing samples sizes and under an increasing number of meta-model evaluations. - Highlights: ► Sensitivity analysis techniques for a model shock physics problem are compared. ► The model problem and the sensitivity analysis problem have exact solutions. ► Subtle details of the method for computing sensitivity indices can affect the results.

  14. A method of increasing the sensitivity of protection from single-phase short-circuits to ground in the 6 – 10 kV network

    International Nuclear Information System (INIS)

    Manilov, A. M.; Mel’nik, D. A.

    2012-01-01

    A method of increasing the sensitivity of protection from single-phase short-circuits to ground by acting on the signal with brief dummy grounding of the neutral is described. After determining the damage, the neutral is again grounded through a high resistance and an arc-quenching reactor. An increase in the protection sensitivity is thereby obtained, the damage detection time is shortened, and the probability of the single-phase short-circuit to ground converting into double and multipoint earth faults is reduced.

  15. Evaluation of phase sensitive detection method and Si avalanche photodiode for radiation thermometry

    International Nuclear Information System (INIS)

    Hobbs, M J; Tan, C H; Willmott, J R

    2013-01-01

    We report the evaluation of Si avalanche photodiodes (APDs) for use in radiation thermometry as an alternative to Si photodiodes. We compared their performance when operated under phase sensitive detection (PSD), where the signal is modulated, and direct detection (DD) methods. A Si APD was compared with a Si photodiode with reference black body temperatures of 275 to 600°C, in terms of the mean output voltage and signal-to-noise ratio (SNR), measured at different APD gain values. We found that using both PSD and DD methods, the high internal gain of the Si APD achieved a lower minimum detection temperature in order to satisfy a specific minimum output voltage of the detector-preamplifier combination employed. The use of PSD over DD for the Si APD allowed for improved performance of the thermometer, with a lower minimum measurable temperature, as well as improvement in the SNR. For instance we found that at 350°C, the Si APD biased at 150 V using PSD can provide ∼ 88 times enhancement in the system SNR over that of a Si photodiode using DD. A corresponding temperature error of ±0.05°C was achieved using the APD with PSD compared to an error of ±2.75°C measured using the Si photodiode with DD.

  16. Sensitization to palladium in Europe

    DEFF Research Database (Denmark)

    Muris, Joris; Goossens, An; Gonçalo, Margarida

    2015-01-01

    BACKGROUND: Recently, sodium tetrachloropalladate (Na2 PdCl4 ) was found to be a more sensitive palladium patch test allergen than palladium dichloride (PdCl2 ). OBJECTIVES: To determine the optimal test concentration of Na2 PdCl4 , to evaluate the prevalence of palladium sensitization with Na2 P...... patch test concentration. Sensitization to palladium is almost as prevalent as sensitization to nickel. The sex distribution is different between nickel-sensitized and palladium-sensitized patients, suggesting different sources of exposure.......Cl4 and PdCl2 , and to compare the results with nickel sensitization in a European multicentre study. MATERIALS AND METHODS: In addition to the European or national baseline series including NiSO4 ·6H2 0 5% pet., consecutive patients were tested with PdCl2 and Na2 PdCl4 2%, 3% and 4% pet. in eight...... European dermatology clinics. The age and sex distributions were also evaluated in patients sensitized to nickel and palladium. RESULTS: In total, 1651 patients were tested. Relative to 3% Na2 PdCl4 , 4% Na2 PdCl4 did not add any information. Two per cent Na2 PdCl4 resulted in more doubtful reactions...

  17. Monte Carlo evaluation of derivative-based global sensitivity measures

    Energy Technology Data Exchange (ETDEWEB)

    Kucherenko, S. [Centre for Process Systems Engineering, Imperial College London, London SW7 2AZ (United Kingdom)], E-mail: s.kucherenko@ic.ac.uk; Rodriguez-Fernandez, M. [Process Engineering Group, Instituto de Investigaciones Marinas, Spanish Council for Scientific Research (C.S.I.C.), C/ Eduardo Cabello, 6, 36208 Vigo (Spain); Pantelides, C.; Shah, N. [Centre for Process Systems Engineering, Imperial College London, London SW7 2AZ (United Kingdom)

    2009-07-15

    A novel approach for evaluation of derivative-based global sensitivity measures (DGSM) is presented. It is compared with the Morris and the Sobol' sensitivity indices methods. It is shown that there is a link between DGSM and Sobol' sensitivity indices. DGSM are very easy to implement and evaluate numerically. The computational time required for numerical evaluation of DGSM is many orders of magnitude lower than that for estimation of the Sobol' sensitivity indices. It is also lower than that for the Morris method. Efficiencies of Monte Carlo (MC) and quasi-Monte Carlo (QMC) sampling methods for calculation of DGSM are compared. It is shown that the superiority of QMC over MC depends on the problem's effective dimension, which can also be estimated using DGSM.

  18. Application of Sensitivity and Uncertainty Analysis Methods to a Validation Study for Weapons-Grade Mixed-Oxide Fuel

    International Nuclear Information System (INIS)

    Dunn, M.E.

    2001-01-01

    At the Oak Ridge National Laboratory (ORNL), sensitivity and uncertainty (S/U) analysis methods and a Generalized Linear Least-Squares Methodology (GLLSM) have been developed to quantitatively determine the similarity or lack thereof between critical benchmark experiments and an application of interest. The S/U and GLLSM methods provide a mathematical approach, which is less judgment based relative to traditional validation procedures, to assess system similarity and estimate the calculational bias and uncertainty for an application of interest. The objective of this paper is to gain experience with the S/U and GLLSM methods by revisiting a criticality safety evaluation and associated traditional validation for the shipment of weapons-grade (WG) MOX fuel in the MO-1 transportation package. In the original validation, critical experiments were selected based on a qualitative assessment of the MO-1 and MOX contents relative to the available experiments. Subsequently, traditional trending analyses were used to estimate the Δk bias and associated uncertainty. In this paper, the S/U and GLLSM procedures are used to re-evaluate the suite of critical experiments associated with the original MO-1 evaluation. Using the S/U procedures developed at ORNL, critical experiments that are similar to the undamaged and damaged MO-1 package are identified based on sensitivity and uncertainty analyses of the criticals and the MO-1 package configurations. Based on the trending analyses developed for the S/U and GLLSM procedures, the Δk bias and uncertainty for the most reactive MO-1 package configurations are estimated and used to calculate an upper subcritical limit (USL) for the MO-1 evaluation. The calculated bias and uncertainty from the S/U and GLLSM analyses lead to a calculational USL that supports the original validation study for the MO-1

  19. Sensitivity/uncertainty analysis of a borehole scenario comparing Latin Hypercube Sampling and deterministic sensitivity approaches

    International Nuclear Information System (INIS)

    Harper, W.V.; Gupta, S.K.

    1983-10-01

    A computer code was used to study steady-state flow for a hypothetical borehole scenario. The model consists of three coupled equations with only eight parameters and three dependent variables. This study focused on steady-state flow as the performance measure of interest. Two different approaches to sensitivity/uncertainty analysis were used on this code. One approach, based on Latin Hypercube Sampling (LHS), is a statistical sampling method, whereas, the second approach is based on the deterministic evaluation of sensitivities. The LHS technique is easy to apply and should work well for codes with a moderate number of parameters. Of deterministic techniques, the direct method is preferred when there are many performance measures of interest and a moderate number of parameters. The adjoint method is recommended when there are a limited number of performance measures and an unlimited number of parameters. This unlimited number of parameters capability can be extremely useful for finite element or finite difference codes with a large number of grid blocks. The Office of Nuclear Waste Isolation will use the technique most appropriate for an individual situation. For example, the adjoint method may be used to reduce the scope to a size that can be readily handled by a technique such as LHS. Other techniques for sensitivity/uncertainty analysis, e.g., kriging followed by conditional simulation, will be used also. 15 references, 4 figures, 9 tables

  20. High-sensitivity imaging method of singlet oxygen and superoxide anion in photodynamic and sonodynamic actions

    Science.gov (United States)

    Xing, Da; He, Yonghong; Hao, Min; Chen, Qun

    2004-07-01

    A novel method of photodynamic diagnosis (PDD) of cancer mediated by chemiluminescence (CL) probe is presented. The mechanism for photodynamic therapy (PDT) involves reactive oxygen species (ROS), such as singlet oxygen (1O2) and superoxide (O2-), generated by during the photochemical process. Both 1O2 and O2- can react with Cypridina luciferin analogue (FCLA), a highly selective CL probe for detecting the ROS. Chemiluminescence from the reaction of FCLA with the ROS, at about 530 nm, was detected by a highly sensitive ICCD system. The CL was markedly inhibited by the addition of 10 mmol/L sodium azide (NaN3) in a sample solution. Similar phenomena, with lesser extents of changes, were observed at the additions of 10 μmol/L superoxide dismutase (SOD), 10 mmol/L mannitol, and 100 μg/mL catalase, respectively. This indicates that the detected CL signals were mainly from ROS generated during the photosensitization reactions. Also, the chemiluminescence method was used to detect the ROS during sonodynamic action, both in vitro and in vivo. ROS formation during sonosensitizations of HpD and ATX-70 were detected using our newly-developed imaging technique, in real time, on tumor bearing animals. This method can provide a new means in clinics for tumor diagnosis.