WorldWideScience

Sample records for sensitive flow-based procedure

  1. A multi-pumping flow-based procedure with improved sensitivity for the spectrophotometric determination of acid-dissociable cyanide in natural waters.

    Science.gov (United States)

    Frizzarin, Rejane M; Rocha, Fábio R P

    2013-01-03

    An analytical procedure with improved sensitivity was developed for cyanide determination in natural waters, exploiting the reaction with the complex of Cu(I) with 2,2'-biquinoline 4,4'-dicarboxylic acid (BCA). The flow system was based on the multi-pumping approach and long pathlength spectrophotometry with a flow cell based on a Teflon AF 2400(®) liquid core waveguide was exploited to increase sensitivity. A linear response was achieved from 5 to 200μg L(-1), with coefficient of variation of 1.5% (n=10). The detection limit and the sampling rate were 2μg L(-1) (99.7% confidence level), and 22h(-1), respectively. Per determination, 48ng of Cu(II), 5μg of ascorbic acid and 0.9μg of BCA were consumed. As high as 100mg L(-1) thiocyanate, nitrite or sulfite did not affect cyanide determination. Sulfide did not interfere at concentrations lower than 40 and 200μg L(-1) before or after sample pretreatment with hydrogen peroxide. The results for natural waters samples agreed with those obtained by a fluorimetric flow-based procedure at the 95% confidence level. The proposed procedure is then a reliable, fast and environmentally friendly alternative for cyanide determination in natural waters. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Procedures for Sensitive Immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Givol, D. [Department of Chemical Immunology, Weizmann Institute of Science, Rehovot (Israel)

    1970-02-15

    Sensitive immunoassay methods should be applied to small molecules of biological importance, which are non-immunogenic by themselves, such as small peptide hormones (e.g. bradykinin), plant hormones (e.g. indoleacetic acid), nucleotides and other small molecules. Methods of binding these small molecules, as haptens, to immunogenic carriers by various cross-linking agents are described (dicyclohexylcarbodiimide, tolylene-diisocyanate and glutaraldehyde), and the considerations involved in relation to the methods of binding and the specificity of the antibodies formed are discussed. Some uses of antibody bound to bromoacetyl cellulose as an immuno adsorbent convenient for assay of immunoglobulins are described. Finally, the sensitive immunoassay method of chemically modified phage is described. This includes methods of binding small molecules (such as the dinitrophenyl group, penicillin, indoleacetic acid) or proteins (such as insulin, immunoglobulins) to phages. Methods of direct chemical conjugation, or an indirect binding via anti-phage Fab, are described. The phage inactivation method by direct plating and its modifications (such as decision technique and complex inactivation) are compared with the more simple end-point titration method. The inhibition of phage inactivation has some advantages as it does not require radioactive material, or expensive radioactive counters, and avoids the need for separation between bound and unbound antigen. Hence, if developed, it could be used as an alternative to radioimmunoassay. (author)

  3. The need for culture sensitive diagnostic procedures

    NARCIS (Netherlands)

    Zandi, Tekleh; Havenaar, Johan M.; Limburg-Okken, Annechien G.; van Es, Hans; Sidali, Salah; Kadri, Nadia; van den Brink, Wim; Kahn, Rene S.

    Objective We examine the procedural validity of a standardized instrument for the diagnosis of psychotic disorders in Morocco. Method Twenty-nine patients from Casablanca, Morocco, with a psychotic or mood disorder were examined using the Comprehensive Assessment of Symptoms and History (CASH) an

  4. OSL sensitivity changes during single aliquot procedures: Computer simulations

    DEFF Research Database (Denmark)

    McKeever, S.W.S.; Agersnap Larsen, N.; Bøtter-Jensen, L.

    1997-01-01

    We present computer simulations of sensitivity changes obtained during single aliquot, regeneration procedures. The simulations indicate that the sensitivity changes are the combined result of shallow trap and deep trap effects. Four separate processes have been identified. Although procedures can...... be suggested to eliminate the shallow trap effects, it appears that the deep trap effects cannot be removed. The character of the sensitivity changes which result from these effects is seen to be dependent upon several external parameters, including the extent of bleaching of the OSL signal, the laboratory...

  5. Parametric Sensitivity Tests- European PEM Fuel Cell Stack Test Procedures

    DEFF Research Database (Denmark)

    Araya, Samuel Simon; Andreasen, Søren Juhl; Kær, Søren Knudsen

    2014-01-01

    performed based on test procedures proposed by a European project, Stack-Test. The sensitivity of a Nafion-based low temperature PEMFC stack’s performance to parametric changes was the main objective of the tests. Four crucial parameters for fuel cell operation were chosen; relative humidity, temperature......As fuel cells are increasingly commercialized for various applications, harmonized and industry-relevant test procedures are necessary to benchmark tests and to ensure comparability of stack performance results from different parties. This paper reports the results of parametric sensitivity tests......, pressure, and stoichiometry at varying current density. Furthermore, procedures for polarization curve recording were also tested both in ascending and descending current directions....

  6. Simplified procedures for fast reactor fuel cycle and sensitivity analysis

    International Nuclear Information System (INIS)

    Badruzzaman, A.

    1979-01-01

    The Continuous Slowing Down-Integral Transport Theory has been extended to perform criticality calculations in a Fast Reactor Core-blanket system achieving excellent prediction of the spectrum and the eigenvalue. The integral transport parameters did not need recalculation with source iteration and were found to be relatively constant with exposure. Fuel cycle parameters were accurately predicted when these were not varied, thus reducing a principal potential penalty of the Intergal Transport approach where considerable effort may be required to calculate transport parameters in more complicated geometries. The small variation of the spectrum in the central core region, and its weak dependence on exposure for both this region, the core blanket interface and blanket region led to the extension and development of inexpensive simplified procedures to complement exact methods. These procedures gave accurate predictions of the key fuel cycle parameters such as cost and their sensitivity to variation in spectrum-averaged and multigroup cross sections. They also predicted the implications of design variation on these parameters very well. The accuracy of these procedures and their use in analyzing a wide variety of sensitivities demonstrate the potential utility of survey calculations in Fast Reactor analysis and fuel management

  7. Numerical Procedure for Optimizing Dye-Sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    Mihai Razvan Mitroi

    2014-01-01

    Full Text Available We propose a numerical procedure consisting of a simplified physical model and a numerical method with the aim of optimizing the performance parameters of dye-sensitized solar cells (DSSCs. We calculate the real rate of absorbed photons (in the dye spectral range Grealx by introducing a factor β<1 in order to simplify the light absorption and reflection on TCO electrode. We consider the electrical transport to be purely diffusive and the recombination process only to occur between electrons from the TiO2 conduction band and anions from the electrolyte. The used numerical method permits solving the system of differential equations resulting from the physical model. We apply the proposed numerical procedure on a classical DSSC based on Ruthenium dye in order to validate it. For this, we simulate the J-V characteristics and calculate the main parameters: short-circuit current density Jsc, open circuit voltage Voc, fill factor FF, and power conversion efficiency η. We analyze the influence of the nature of semiconductor (TiO2 and dye and also the influence of different technological parameters on the performance parameters of DSSCs. The obtained results show that the proposed numerical procedure is suitable for developing a numerical simulation platform for improving the DSSCs performance by choosing the optimal parameters.

  8. Sensitivity of Hydrologic Response to Climate Model Debiasing Procedures

    Science.gov (United States)

    Channell, K.; Gronewold, A.; Rood, R. B.; Xiao, C.; Lofgren, B. M.; Hunter, T.

    2017-12-01

    Climate change is already having a profound impact on the global hydrologic cycle. In the Laurentian Great Lakes, changes in long-term evaporation and precipitation can lead to rapid water level fluctuations in the lakes, as evidenced by unprecedented change in water levels seen in the last two decades. These fluctuations often have an adverse impact on the region's human, environmental, and economic well-being, making accurate long-term water level projections invaluable to regional water resources management planning. Here we use hydrological components from a downscaled climate model (GFDL-CM3/WRF), to obtain future water supplies for the Great Lakes. We then apply a suite of bias correction procedures before propagating these water supplies through a routing model to produce lake water levels. Results using conventional bias correction methods suggest that water levels will decline by several feet in the coming century. However, methods that reflect the seasonal water cycle and explicitly debias individual hydrological components (overlake precipitation, overlake evaporation, runoff) imply that future water levels may be closer to their historical average. This discrepancy between debiased results indicates that water level forecasts are highly influenced by the bias correction method, a source of sensitivity that is commonly overlooked. Debiasing, however, does not remedy misrepresentation of the underlying physical processes in the climate model that produce these biases and contribute uncertainty to the hydrological projections. This uncertainty coupled with the differences in water level forecasts from varying bias correction methods are important for water management and long term planning in the Great Lakes region.

  9. Flow-Based Provenance

    Directory of Open Access Journals (Sweden)

    Sabah Al-Fedaghi

    2017-02-01

    Full Text Available Aim/Purpose: With information almost effortlessly created and spontaneously available, current progress in Information and Communication Technology (ICT has led to the complication that information must be scrutinized for trustworthiness and provenance. Information systems must become provenance-aware to be satisfactory in accountability, reproducibility, and trustworthiness of data. Background:\tMultiple models for abstract representation of provenance have been proposed to describe entities, people, and activities involved in producing a piece of data, including the Open Provenance Model (OPM and the World Wide Web Consortium. These models lack certain concepts necessary for specifying workflows and encoding the provenance of data products used and generated. Methodology: Without loss of generality, the focus of this paper is on OPM depiction of provenance in terms of a directed graph. We have redrawn several case studies in the framework of our proposed model in order to compare and evaluate it against OPM for representing these cases. Contribution: This paper offers an alternative flow-based diagrammatic language that can form a foundation for modeling of provenance. The model described here provides an (abstract machine-like representation of provenance. Findings: The results suggest a viable alternative in the area of diagrammatic representation for provenance applications. Future Research: Future work will seek to achieve more accurate comparisons with current models in the field.

  10. A simple procedure for measuring pharyngeal sensitivity: a contribution to the diagnosis of sleep apnoea

    OpenAIRE

    Dematteis, M; Levy, P; Pepin, J

    2005-01-01

    Background: Patients with severe apnoea may have an impaired pharyngeal dilating reflex related to decreased pharyngeal sensitivity. The accuracy of a simple new procedure to measure pharyngeal sensitivity and to diagnose sleep disordered breathing (SDB) was investigated.

  11. Procedures for uncertainty and sensitivity analysis in repository performance assessment

    International Nuclear Information System (INIS)

    Poern, K.; Aakerlund, O.

    1985-10-01

    The objective of the project was mainly a literature study of available methods for the treatment of parameter uncertainty propagation and sensitivity aspects in complete models such as those concerning geologic disposal of radioactive waste. The study, which has run parallel with the development of a code package (PROPER) for computer assisted analysis of function, also aims at the choice of accurate, cost-affective methods for uncertainty and sensitivity analysis. Such a choice depends on several factors like the number of input parameters, the capacity of the model and the computer reresources required to use the model. Two basic approaches are addressed in the report. In one of these the model of interest is directly simulated by an efficient sampling technique to generate an output distribution. Applying the other basic method the model is replaced by an approximating analytical response surface, which is then used in the sampling phase or in moment matching to generate the output distribution. Both approaches are illustrated by simple examples in the report. (author)

  12. An improved approach for flow-based cloud point extraction.

    Science.gov (United States)

    Frizzarin, Rejane M; Rocha, Fábio R P

    2014-04-11

    Novel strategies are proposed to circumvent the main drawbacks of flow-based cloud point extraction (CPE). The surfactant-rich phase (SRP) was directly retained into the optical path of the spectrophotometric cell, thus avoiding its dilution previously to the measurement and yielding higher sensitivity. Solenoid micro-pumps were exploited to improve mixing by the pulsed flow and also to modulate the flow-rate for retention and removal of the SRP, thus avoiding the elution step, often carried out with organic solvents. The heat released and the increase of the salt concentration provided by an on-line neutralization reaction were exploited to induce the cloud point without an external heating device. These innovations were demonstrated by the spectrophotometric determination of iron, yielding a linear response from 10 to 200 μg L(-1) with a coefficient of variation of 2.3% (n=7). Detection limit and sampling rate were estimated at 5 μg L(-1) (95% confidence level) and 26 samples per hour, respectively. The enrichment factor was 8.9 and the procedure consumed only 6 μg of TAN and 390 μg of Triton X-114 per determination. At the 95% confidence level, the results obtained for freshwater samples agreed with the reference procedure and those obtained for digests of bovine muscle, rice flour, brown bread and tort lobster agreed with the certified reference values. The proposed procedure thus shows advantages in relation to previously proposed approaches for flow-based CPE, being a fast and environmental friendly alternative for on-line separation and pre-concentration. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. An automated sensitivity analysis procedure for the performance assessment of nuclear waste isolation systems

    International Nuclear Information System (INIS)

    Pin, F.G.; Worley, B.A.; Oblow, E.M.; Wright, R.Q.; Harper, W.V.

    1986-01-01

    To support an effort in making large-scale sensitivity analyses feasible, cost efficient and quantitatively complete, the authors have developed an automated procedure making use of computer calculus. The procedure, called GRESS (GRadient Enhanced Software System), is embodied in a precompiler that can process Fortran computer codes and add derivative-taking capabilities to the normal calculation scheme. In this paper, the automated GRESS procedure is described and applied to the code UCB-NE-10.2, which simulates the migration through a sorption medium of the radionuclide members of a decay chain. The sensitivity calculations for a sample problem are verified using comparison with analytical and perturbation analysis results. Conclusions are drawn relative to the applicability of GRESS for more general large-scale sensitivity studies, and the role of such techniques in an overall sensitivity and uncertainty analysis program is discussed

  14. A procedure for the improvement in the determination of a TXRF spectrometer sensitivity curve

    International Nuclear Information System (INIS)

    Bennun, Leonardo; Sanhueza, Vilma

    2010-01-01

    A simple procedure is proposed to determine the total reflection X-ray fluorescence (TXRF) spectrometer sensitivity curve; this procedure provides better accuracy and exactitude than the standard established method. It uses individual pure substances instead of the use of vendor-certified values of reference calibration standards, which are expensive and lack any method to check their quality. This method avoids problems like uncertainties in the determination of the sensitivity curve according to different standards. It also avoids the need for validation studies between different techniques, in order to assure the quality of their TXRF results. (author)

  15. Automated procedure for calculating time-dependent sensitivities in ORIGEN2

    International Nuclear Information System (INIS)

    Worley, B.A.; Wright, R.Q.

    1985-10-01

    ORIGEN2 is a widely used point-depletion and radioactive-decay computer code for use in simulating nuclear fuel cycles and/or spent fuel characteristics. This paper presents the application of the GRESS procedure to the ORIGEN2 code for performing a sensitivity analysis of a high-level waste disposal problem. The GRESS procedure uses computer calculus and the GRESS precompiler to automate the generation and calculation of gradients in a computer code. The GRESS version of ORIGEN2 is used to calculate the nuclide-dependent sensitivities of the decay heat and radioactivity of 1008 nuclides comprising reprocessed high-level waste to changes in data and input parameters. The sensitivities are calculated in a single execution of the revised code as compared to the conventional method of rerunning the code numerous times. The availability of sensitivity data as an option in ORIGEN2 reveals relationships not easily recognized even with reruns

  16. A Comparison of Procedures for Content-Sensitive Item Selection in Computerized Adaptive Tests.

    Science.gov (United States)

    Kingsbury, G. Gage; Zara, Anthony R.

    1991-01-01

    This simulation investigated two procedures that reduce differences between paper-and-pencil testing and computerized adaptive testing (CAT) by making CAT content sensitive. Results indicate that the price in terms of additional test items of using constrained CAT for content balancing is much smaller than that of using testlets. (SLD)

  17. Parametric Sensitivity Tests—European Polymer Electrolyte Membrane Fuel Cell Stack Test Procedures

    DEFF Research Database (Denmark)

    Araya, Samuel Simon; Andreasen, Søren Juhl; Kær, Søren Knudsen

    2014-01-01

    performed based on test procedures proposed by a European project, Stack-Test. The sensitivity of a Nafion-based low temperature PEMFC stack’s performance to parametric changes was the main objective of the tests. Four crucial parameters for fuel cell operation were chosen; relative humidity, temperature......As fuel cells are increasingly commercialized for various applications, harmonized and industry-relevant test procedures are necessary to benchmark tests and to ensure comparability of stack performance results from different parties. This paper reports the results of parametric sensitivity tests......, pressure, and stoichiometry at varying current density. Furthermore, procedures for polarization curve recording were also tested both in ascending and descending current directions....

  18. Thermoluminescence sensitivity variations in LiF PTFE dosemeters incurred by improper handling procedures

    CERN Document Server

    Mason, E W; MacKinlay, Alistair F; Saunders, D

    1975-01-01

    A systematic study of some anomalous darkening effects and thermoluminescence sensitivity variations observed in LiF:PTFE thermoluminescent dosemeters is described. Various likely causes of such effects have been investigated. The manufacturer's recommended cleaning procedures have been found to be inadequate and, in some cases, have been found to actually promote discolouration of the dosemeters. Recommendations are given for the successful use of LiF:PTFE thermoluminescent dosemeters in personal dosimetry.

  19. Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jones, A. Kyle, E-mail: kyle.jones@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Pasciak, Alexander S. [Department of Radiology, The University of Tennessee Medical Center at Knoxville, Knoxville, Tennessee 37922 (United States); Wagner, Louis K. [Department of Diagnostic and Interventional Imaging, The John P. and Katharine G. McGovern Medical School, Houston, Texas 77030 (United States)

    2016-07-15

    Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

  20. A Computational Model of the Temporal Dynamics of Plasticity in Procedural Learning: Sensitivity to Feedback Timing

    Directory of Open Access Journals (Sweden)

    Vivian V. Valentin

    2014-07-01

    Full Text Available The evidence is now good that different memory systems mediate the learning of different types of category structures. In particular, declarative memory dominates rule-based (RB category learning and procedural memory dominates information-integration (II category learning. For example, several studies have reported that feedback timing is critical for II category learning, but not for RB category learning – results that have broad support within the memory systems literature. Specifically, II category learning has been shown to be best with feedback delays of 500ms compared to delays of 0 and 1000ms, and highly impaired with delays of 2.5 seconds or longer. In contrast, RB learning is unaffected by any feedback delay up to 10 seconds. We propose a neurobiologically detailed theory of procedural learning that is sensitive to different feedback delays. The theory assumes that procedural learning is mediated by plasticity at cortical-striatal synapses that are modified by dopamine-mediated reinforcement learning. The model captures the time-course of the biochemical events in the striatum that cause synaptic plasticity, and thereby accounts for the empirical effects of various feedback delays on II category learning.

  1. Magnetic particles as powerful purification tool for high sensitive mass spectrometric screening procedures.

    Science.gov (United States)

    Peter, Jochen F; Otto, Angela M

    2010-02-01

    The effective isolation and purification of proteins from biological fluids is the most crucial step for a successful protein analysis when only minute amounts are available. While conventional purification methods such as dialysis, ultrafiltration or protein precipitation often lead to a marked loss of protein, SPE with small-sized particles is a powerful alternative. The implementation of particles with superparamagnetic cores facilitates the handling of those particles and allows the application of particles in the nanometer to low micrometer range. Due to the small diameters, magnetic particles are advantageous for increasing sensitivity when using subsequent MS analysis or gel electrophoresis. In the last years, different types of magnetic particles were developed for specific protein purification purposes followed by analysis or screening procedures using MS or SDS gel electrophoresis. In this review, the use of magnetic particles for different applications, such as, the extraction and analysis of DNA/RNA, peptides and proteins, is described.

  2. Method matters: systematic effects of testing procedure on visual working memory sensitivity.

    Science.gov (United States)

    Makovski, Tal; Watson, Leah M; Koutstaal, Wilma; Jiang, Yuhong V

    2010-11-01

    Visual working memory (WM) is traditionally considered a robust form of visual representation that survives changes in object motion, observer's position, and other visual transients. This article presents data that are inconsistent with the traditional view. We show that memory sensitivity is dramatically influenced by small variations in the testing procedure, supporting the idea that representations in visual WM are susceptible to interference from testing. In the study, participants were shown an array of colors to remember. After a short retention interval, memory for one of the items was tested with either a same-different task or a 2-alternative-forced-choice (2AFC) task. Memory sensitivity was much lower in the 2AFC task than in the same-different task. This difference was found regardless of encoding similarity or of whether visual WM required a fine or coarse memory resolution. The 2AFC disadvantage was reduced when participants were informed shortly before testing which item would be probed. The 2AFC disadvantage diminished in perceptual tasks and was not found in tasks probing visual long-term memory. These results support memory models that acknowledge the labile nature of visual WM and have implications for the format of visual WM and its assessment. (c) 2010 APA, all rights reserved

  3. The sensitivity of characteristics of cyclone activity to identification procedures in tracking algorithms

    Directory of Open Access Journals (Sweden)

    Irina Rudeva

    2014-12-01

    Full Text Available The IMILAST project (‘Intercomparison of Mid-Latitude Storm Diagnostics’ was set up to compare low-level cyclone climatologies derived from a number of objective identification algorithms. This paper is a contribution to that effort where we determine the sensitivity of three key aspects of Northern Hemisphere cyclone behaviour [namely the number of cyclones, their intensity (defined here in terms of the central pressure and their deepening rates] to specific features in the automatic cyclone identification. The sensitivity is assessed with respect to three such features which may be thought to influence the ultimate climatology produced (namely performance in areas of complicated orography, time of the detection of a cyclone, and the representation of rapidly propagating cyclones. We make use of 13 tracking methods in this analysis. We find that the filtering of cyclones in regions where the topography exceeds 1500 m can significantly change the total number of cyclones detected by a scheme, but has little impact on the cyclone intensity distribution. More dramatically, late identification of cyclones (simulated by the truncation of the first 12 hours of cyclone life cycle leads to a large reduction in cyclone numbers over the both continents and oceans (up to 80 and 40%, respectively. Finally, the potential splitting of the trajectories at times of the fastest propagation has a negligible climatological effect on geographical distribution of cyclone numbers. Overall, it has been found that the averaged deepening rates and averaged cyclone central pressure are rather insensitive to the specifics of the tracking procedure, being more sensitive to the data set used (as shown in previous studies and the geographical location of a cyclone.

  4. A Sensitive Photometric Procedure for Cobalt Determination in Water Employing a Compact Multicommuted Flow Analysis System.

    Science.gov (United States)

    da Silva Magalhães, Ticiane; Reis, Boaventura F

    2017-09-01

    In this work, a multicommuted flow analysis procedure is proposed for the spectrophotometric determination of cobalt in fresh water, employing an instrument setup of downsized dimension and improved cost-effectiveness. The method is based on the catalytic effect of Co(II) on the Tiron oxidation by hydrogen peroxide in alkaline medium, forming a complex that absorbs radiation at 425 nm. The photometric detection was accomplished using a homemade light-emitting-diode (LED)-based photometer designed to use a flow cell with an optical path-length of 100 mm to improve sensitivity. After selecting adequate values for the flow system variables, adherence to the Beer-Lambert-Bouguer law was observed for standard solution concentrations in the range of 0.13-1.5 µg L -1 Co(II). Other useful features including a relative standard deviation of 2.0% (n = 11) for a sample with 0.49 µg L -1 Co(II), a detection limit of 0.06 µg L -1 Co(II) (n = 20), an analytical frequency of 42 sample determinations per hour, and waste generation of 1.5 mL per determination were achieved.

  5. Sensitivity of tropical convection in cloud-resolving WRF simulations to model physics and forcing procedures

    Science.gov (United States)

    Endo, S.; Lin, W.; Jackson, R. C.; Collis, S. M.; Vogelmann, A. M.; Wang, D.; Oue, M.; Kollias, P.

    2017-12-01

    Tropical convection is one of the main drivers of the climate system and recognized as a major source of uncertainty in climate models. High-resolution modeling is performed with a focus on the deep convection cases during the active monsoon period of the TWP-ICE field campaign to explore ways to improve the fidelity of convection permitting tropical simulations. Cloud resolving model (CRM) simulations are performed with WRF modified to apply flexible configurations for LES/CRM simulations. We have enhanced the capability of the forcing module to test different implementations of large-scale vertical advective forcing, including a function for optional use of large-scale thermodynamic profiles and a function for the condensate advection. The baseline 3D CRM configurations are, following Fridlind et al. (2012), driven by observationally-constrained ARM forcing and tested with diagnosed surface fluxes and fixed sea-surface temperature and prescribed aerosol size distributions. After the spin-up period, the simulations follow the observed precipitation peaks associated with the passages of precipitation systems. Preliminary analysis shows that the simulation is generally not sensitive to the treatment of the large-scale vertical advection of heat and moisture, while more noticeable changes in the peak precipitation rate are produced when thermodynamic profiles above the boundary layer were nudged to the reference profiles from the forcing dataset. The presentation will explore comparisons with observationally-based metrics associated with convective characteristics and examine the model performance with a focus on model physics, doubly-periodic vs. nested configurations, and different forcing procedures/sources. A radar simulator will be used to understand possible uncertainties in radar-based retrievals of convection properties. Fridlind, A. M., et al. (2012), A comparison of TWP-ICE observational data with cloud-resolving model results, J. Geophys. Res., 117, D05204

  6. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Guogen Shan

    2015-01-01

    Full Text Available Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003. However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization.

  7. Implementation and evaluation of nonparametric regression procedures for sensitivity analysis of computationally demanding models

    International Nuclear Information System (INIS)

    Storlie, Curtis B.; Swiler, Laura P.; Helton, Jon C.; Sallaberry, Cedric J.

    2009-01-01

    The analysis of many physical and engineering problems involves running complex computational models (simulation models, computer codes). With problems of this type, it is important to understand the relationships between the input variables (whose values are often imprecisely known) and the output. The goal of sensitivity analysis (SA) is to study this relationship and identify the most significant factors or variables affecting the results of the model. In this presentation, an improvement on existing methods for SA of complex computer models is described for use when the model is too computationally expensive for a standard Monte-Carlo analysis. In these situations, a meta-model or surrogate model can be used to estimate the necessary sensitivity index for each input. A sensitivity index is a measure of the variance in the response that is due to the uncertainty in an input. Most existing approaches to this problem either do not work well with a large number of input variables and/or they ignore the error involved in estimating a sensitivity index. Here, a new approach to sensitivity index estimation using meta-models and bootstrap confidence intervals is described that provides solutions to these drawbacks. Further, an efficient yet effective approach to incorporate this methodology into an actual SA is presented. Several simulated and real examples illustrate the utility of this approach. This framework can be extended to uncertainty analysis as well.

  8. Testing taste sensitivity and aversion in very young children : development of a procedure

    NARCIS (Netherlands)

    Visser, J; Kroeze, J.H.A.; Kamps, WA; Bijleveld, CMA

    Taste perception in 45 3- to 6-year-old children was tested using procedures specifically designed for this age group. Detection thresholds for sucrose and urea were measured by a staircase method and aversion to urea was assessed hedonically, using drawings of facial expressions. All children

  9. SU-D-209-05: Sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to Procedural Factors in Fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jones, A [UT MD Anderson Cancer Center, Houston, TX (United States); Pasciak, A [University of Tennessee Medical Center, Knoxville, TN (United States); Wagner, L [UT Medical School, Houston, TX (United States)

    2016-06-15

    Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.

  10. Method Matters: Systematic Effects of Testing Procedure on Visual Working Memory Sensitivity

    Science.gov (United States)

    Makovski, Tal; Watson, Leah M.; Koutstaal, Wilma; Jiang, Yuhong V.

    2010-01-01

    Visual working memory (WM) is traditionally considered a robust form of visual representation that survives changes in object motion, observer's position, and other visual transients. This article presents data that are inconsistent with the traditional view. We show that memory sensitivity is dramatically influenced by small variations in the…

  11. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Directory of Open Access Journals (Sweden)

    Alexander J Taylor

    Full Text Available Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  12. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Science.gov (United States)

    Taylor, Alexander J; Granwehr, Josef; Lesbats, Clémentine; Krupa, James L; Six, Joseph S; Pavlovskaya, Galina E; Thomas, Neil R; Auer, Dorothee P; Meersmann, Thomas; Faas, Henryk M

    2016-01-01

    Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI) using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  13. Specific Disgust Sensitivities Differentially Predict Interest in Careers of Varying Procedural-Intensity among Medical Students

    Science.gov (United States)

    Consedine, Nathan S.; Windsor, John A.

    2014-01-01

    Mismatches between the needs of public health systems and student interests have led to renewed study on the factors predicting career specializations among medical students. While most work examines career and lifestyle values, emotional proclivities may be important; disgust sensitivity may help explain preferences for careers with greater and…

  14. A Highly Sensitive Multicommuted Flow Analysis Procedure for Photometric Determination of Molybdenum in Plant Materials without a Solvent Extraction Step

    Directory of Open Access Journals (Sweden)

    Felisberto G. Santos

    2017-01-01

    Full Text Available A highly sensitive analytical procedure for photometric determination of molybdenum in plant materials was developed and validated. This procedure is based on the reaction of Mo(V with thiocyanate ions (SCN− in acidic medium to form a compound that can be monitored at 474 nm and was implemented employing a multicommuted flow analysis setup. Photometric detection was performed using an LED-based photometer coupled to a flow cell with a long optical path length (200 mm to achieve high sensitivity, allowing Mo(V determination at a level of μg L−1 without the use of an organic solvent extraction step. After optimization of operational conditions, samples of digested plant materials were analyzed employing the proposed procedure. The accuracy was assessed by comparing the obtained results with those of a reference method, with an agreement observed at 95% confidence level. In addition, a detection limit of 9.1 μg L−1, a linear response (r=0.9969 over the concentration range of 50–500 μg L−1, generation of only 3.75 mL of waste per determination, and a sampling rate of 51 determinations per hour were achieved.

  15. Adjoint sensitivity analysis procedure of Markov chains with applications on reliability of IFMIF accelerator-system facilities

    Energy Technology Data Exchange (ETDEWEB)

    Balan, I.

    2005-05-01

    This work presents the implementation of the Adjoint Sensitivity Analysis Procedure (ASAP) for the Continuous Time, Discrete Space Markov chains (CTMC), as an alternative to the other computational expensive methods. In order to develop this procedure as an end product in reliability studies, the reliability of the physical systems is analyzed using a coupled Fault-Tree - Markov chain technique, i.e. the abstraction of the physical system is performed using as the high level interface the Fault-Tree and afterwards this one is automatically converted into a Markov chain. The resulting differential equations based on the Markov chain model are solved in order to evaluate the system reliability. Further sensitivity analyses using ASAP applied to CTMC equations are performed to study the influence of uncertainties in input data to the reliability measures and to get the confidence in the final reliability results. The methods to generate the Markov chain and the ASAP for the Markov chain equations have been implemented into the new computer code system QUEFT/MARKOMAGS/MCADJSEN for reliability and sensitivity analysis of physical systems. The validation of this code system has been carried out by using simple problems for which analytical solutions can be obtained. Typical sensitivity results show that the numerical solution using ASAP is robust, stable and accurate. The method and the code system developed during this work can be used further as an efficient and flexible tool to evaluate the sensitivities of reliability measures for any physical system analyzed using the Markov chain. Reliability and sensitivity analyses using these methods have been performed during this work for the IFMIF Accelerator System Facilities. The reliability studies using Markov chain have been concentrated around the availability of the main subsystems of this complex physical system for a typical mission time. The sensitivity studies for two typical responses using ASAP have been

  16. A very sensitive LSC procedure to determine Ni-63 in environmental samples, steel and concrete

    International Nuclear Information System (INIS)

    Scheuerer, C.; Schupfner, R.; Schuettelkopf, H.

    1995-01-01

    This procedure to determine Ni-63 contributes to a safe and economically reasonable decommissioning of nuclear power plants. Co-60, Fe-55 and Ni-63 are the most abundant long-lived radionuclides associated with contaminated piping, hardware and concrete for a period of several decades of years after shutdown. Samples are carefully ashed leached, or dissolved by suitable mixtures of acids. The analysis starts with the absorption Ni 2+ on the chelating resin CHELEX 100. The next purification steps include an anionic exchange column and a precipitation as Ni-dimethyl-glyoxime, which is extracted into chloroform. After reextraction with sulfuric acid the solution containing Ni 2+ is mixed with a scintillation cocktail and counted in an anticoincidence shielded LSC. The decontamination factors are determined for all important artificially and naturally occurring radionuclides ranging form above 10 4 to 10 9 . The chemical yield adopts a value of (95±5)%. Up to maximum sample amounts of 0.4 g steel, 5 g concrete and about 100 g of environmental samples the detection limits are about 5 mBq per sample or 12 mBq/g steel, 1 mBq/g concrete and 0.05 mBq/g environmental sample at a counting time of 1000 minutes. (author) 16 refs.; 2 figs.; 2 tabs

  17. A fast and very sensitive LSC procedure to determine Fe-55 in steel and concrete

    International Nuclear Information System (INIS)

    Koenig, W.; Schupfner, R.; Schuettelkopf, H.

    1995-01-01

    This procedure determining Fe-55 contributes to a safe and economically reasonable decommissioning of nuclear power plants. Co-60, Fe-55 and Ni-63 are the most abundant, long-lived radionuclides associated with contaminated piping, hardware, and concrete for several decades of years after shutdown. The analysis of Fe takes about three hours until the measurement with an anticoincidence shielded LSC Quantulus 1220 starts. The decontamination factors are ranging from greater than 10 5 to 10 9 for all important naturally and artificially occurring radionuclides except Sb. The chemical yield stays constant at a value of about 92% up to 0.1 g stable Fe in steel, concrete or other material. The detection limits (confidence level 95%) reach values of 8 mBq per sample or about 60 mBq/g steel and 1.5 mBq/g concrete at a counting time of 1000 minutes. Four to eight analyses are performed by one technician during eight hours. (author) 16 refs.; 2 figs.; 4 tabs

  18. Volcanic Ash and SO2 retrievals using synthetic MODIS TIR data: comparison between inversion procedures and sensitivity analysis

    Directory of Open Access Journals (Sweden)

    Stefano Corradini

    2015-02-01

    Full Text Available In this work the volcanic ash and SO2 retrievals obtained by applying three different procedures (LUT - Look Up Table, NN - Neural Network and VPR - Volcanic Plume Removal on MODIS Thermal InfraRed (TIR synthetic measurements have been compared. The synthetic measurements are generated using MODTRAN Radiative Transfer Model (RTM for defined volcanic cloud configurations. The results, presented as the percentage difference between the retrieved ash and SO2 total masses and the true values used for the synthetic data generation, indicate maximum differences of +/- 15% and +/- 10% for all the procedures and for ash and SO2 retrievals respectively. A sensitivity analysis has been also realized to investigate the influence of volcanic cloud altitude and water vapour profile on SO2 retrievals at 7.3 and 8.6 μm. Results confirm the high sensitivity of the 7.3 μm retrieval to the volcanic cloud altitude and show that the SO2 total masses estimated at 7.3 and 8.6 μm separately can be used to improve the information on the plume height. Finally, the water vapour profile is used to compute the minimum altitude over which the 7.3 μm retrieval is effective. 

  19. Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y.; Wuu, Cheng-Shie; Maryanski, Marek J. [Department of Radiation Oncology, Columbia University, New York, New York 10032 (United States); Department of Radiation Oncology, Columbia University, New York, New York 10032 and MGS Research Inc., Madison, Connecticut 06443 (United States)

    2010-02-15

    The dose response of the BANG 3 polymer gel dosimeter (MGS Research Inc., Madison, CT) was studied using the OCTOPUS laser CT scanner (MGS Research Inc., Madison, CT). Six 17 cm diameter and 12 cm high Barex cylinders, and 18 small glass vials were used to house the gel. The gel phantoms were irradiated with 6 and 10 MV photons, as well as 12 and 16 MeV electrons using a Varian Clinac 2100EX. Three calibration methods were used to obtain the dose response curves: (a) Optical density measurements on the 18 glass vials irradiated with graded doses from 0 to 4 Gy using 6 or 10 MV large field irradiations; (b) optical-CT scanning of Barex cylinders irradiated with graded doses (0.5, 1, 1.5, and 2 Gy) from four adjacent 4x4 cm{sup 2} photon fields or 6x6 cm{sup 2} electron fields; and (c) percent depth dose (PDD) comparison of optical-CT scans with ion chamber measurements for 6x6 cm{sup 2}, 12 and 16 MeV electron fields. The dose response of the BANG 3 gel was found to be linear and energy independent within the uncertainties of the experimental methods (about 3%). The slopes of the linearly fitted dose response curves (dose sensitivities) from the four field irradiations (0.0752{+-}3%, 0.0756{+-}3%, 0.0767{+-}3%, and 0.0759{+-}3% cm{sup -1} Gy{sup -1}) and the PDD matching methods (0.0768{+-}3% and 0.0761{+-}3% cm{sup -1} Gy{sup -1}) agree within 2.2%, indicating a good reproducibility of the gel dose response within phantoms of the same geometry. The dose sensitivities from the glass vial approach are different from those of the cylindrical Barex phantoms by more than 30%, owing probably to the difference in temperature inside the two types of phantoms during gel formation and irradiation, and possible oxygen contamination of the glass vial walls. The dose response curve obtained from the PDD matching approach with 16 MeV electron field was used to calibrate the gel phantom irradiated with the 12 MeV, 6x6 cm{sup 2} electron field. Three-dimensional dose distributions

  20. Risk evaluations of aging: Procedures guide for an age-dependent PSA with emphasis on prioritization and sensitivity studies

    International Nuclear Information System (INIS)

    Vesely, W.E.

    1991-01-01

    Based on the previous work which has been performed in the project, a procedures guide is being developed for carrying out an age-dependent probabilistic safety assessment (PSA) for evaluating the core damage frequency with aging effects explicitly treated. A PSA is basically a Level 1 Probabilistic Risk Assessment (PRA). The emphasis of the guide is on prioritization and sensitivity studies. Focus is also on active components although consideration of aging effects in passive components is also treated. The guide is intended to become a NUREG/CR and is the first of three volumes which are being developed. The following topics with demonstrations and applications are described in the presentation: (1) the age-dependent PSA versus the standard PSA; (2) component reliability models used in an age-dependent PSA; (3) approaches for transforming a PSA into an age-dependent PSA; (4) application of an age-dependent PSA; (5) using a PSA to evaluate the risk effects from aging passive components; (6) evaluation of the risk importance of passive components; (7) prioritizations of aging contributors; (8) evaluations of test and maintenance effectiveness; and (9) sensitivity studies and uncertainty analyses of aging effects

  1. A Labeled Data Set For Flow-based Intrusion Detection

    NARCIS (Netherlands)

    Sperotto, Anna; Sadre, R.; van Vliet, Frank; Pras, Aiko; Nunzi, Giorgio; Scoglio, Caterina; Li, Xing

    2009-01-01

    Flow-based intrusion detection has recently become a promising security mechanism in high speed networks (1-10 Gbps). Despite the richness in contributions in this field, benchmarking of flow-based IDS is still an open issue. In this paper, we propose the first publicly available, labeled data set

  2. Material flow-based economic assessment of landfill mining processes.

    Science.gov (United States)

    Kieckhäfer, Karsten; Breitenstein, Anna; Spengler, Thomas S

    2017-02-01

    This paper provides an economic assessment of alternative processes for landfill mining compared to landfill aftercare with the goal of assisting landfill operators with the decision to choose between the two alternatives. A material flow-based assessment approach is developed and applied to a landfill in Germany. In addition to landfill aftercare, six alternative landfill mining processes are considered. These range from simple approaches where most of the material is incinerated or landfilled again to sophisticated technology combinations that allow for recovering highly differentiated products such as metals, plastics, glass, recycling sand, and gravel. For the alternatives, the net present value of all relevant cash flows associated with plant installation and operation, supply, recycling, and disposal of material flows, recovery of land and landfill airspace, as well as landfill closure and aftercare is computed with an extensive sensitivity analyses. The economic performance of landfill mining processes is found to be significantly influenced by the prices of thermal treatment (waste incineration as well as refuse-derived fuels incineration plant) and recovered land or airspace. The results indicate that the simple process alternatives have the highest economic potential, which contradicts the aim of recovering most of the resources. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Patient flow based allocation of hospital resources.

    Science.gov (United States)

    Vissers, J M

    1995-01-01

    The current practice of allocating resources within a hospital introduces peaks and troughs in the workloads of departments and leads therefore to loss of capacity. This happens when requirements for capacity coordination are not adequately taken into account in the decision making process of allocating resources to specialties. The first part of this research involved an analysis of the hospital's production system on dependencies between resources, resulting in a number of capacity coordination requirements that need to be fulfilled for optimized resource utilization. The second, modelling, part of the study involved the development of a framework for resource management decision making, of a set of computer models to support hospital managerial decision making on resource allocation issues in various parts of the hospital, and of an implementation strategy for the application of the models to concrete hospital settings. The third part of the study was devoted to a number of case-studies, illustrating the use of the models when applied in various resource management projects, such as a reorganization of an operating theatre timetable, or the development of a master plan for activities of a group of general surgeons serving two locations of a merged hospital system. The paper summarizes the main findings of the study and concludes with a discussion of results obtained with the new allocation procedure and with recommendations for future research.

  4. Information-flow-based Access Control for Virtualized Systems

    Directory of Open Access Journals (Sweden)

    Dmitriy Aleksandrovich Postoev

    2014-12-01

    Full Text Available The article is devoted to the method of information-flow-based access control, adopted for virtualized systems. General structure of access control system for virtual infrastructure is proposed.

  5. A network-flow based valve-switching aware binding algorithm for flow-based microfluidic biochips

    DEFF Research Database (Denmark)

    Tseng, Kai-Han; You, Sheng-Chi; Minhass, Wajid Hassan

    2013-01-01

    -flow based resource binding algorithm based on breadth-first search (BFS) and minimum cost maximum flow (MCMF) in architectural-level synthesis. The experimental results show that our methodology not only makes significant reduction of valve-switching activities but also diminishes the application completion......Designs of flow-based microfluidic biochips are receiving much attention recently because they replace conventional biological automation paradigm and are able to integrate different biochemical analysis functions on a chip. However, as the design complexity increases, a flow-based microfluidic...... biochip needs more chip-integrated micro-valves, i.e., the basic unit of fluid-handling functionality, to manipulate the fluid flow for biochemical applications. Moreover, frequent switching of micro-valves results in decreased reliability. To minimize the valve-switching activities, we develop a network...

  6. Flowbca : A flow-based cluster algorithm in Stata

    NARCIS (Netherlands)

    Meekes, J.; Hassink, W.H.J.

    In this article, we introduce the Stata implementation of a flow-based cluster algorithm written in Mata. The main purpose of the flowbca command is to identify clusters based on relational data of flows. We illustrate the command by providing multiple applications, from the research fields of

  7. Towards Separation of Concerns in Flow-Based Programming

    DEFF Research Database (Denmark)

    Zarrin, Bahram; Baumeister, Hubert

    2015-01-01

    Flow-Based Programming (FBP) is a programming paradigm that models software systems as a directed graph of predefined processes which run asynchronously and exchange data through input and output ports. FBP decomposes software systems into a network of processes. However there are concerns...

  8. Trends in Flow-based Biosensing Systems for Pesticide Assessment

    Directory of Open Access Journals (Sweden)

    Jean-Louis Marty

    2006-10-01

    Full Text Available This review gives a survey on the state of the art of pesticide detection usingflow-based biosensing systems for sample screening. Although immunosensor systems havebeen proposed as powerful pesticide monitoring tools, this review is mainly focused onenzyme-based biosensors, as they are the most commonly employed when using a flowsystem. Among the different detection methods able to be integrated into flow-injectionanalysis (FIA systems, the electrochemical ones will be treated in more detail, due to theirhigh sensitivity, simple sample pretreatment, easy operational procedures and real-timedetection. During the last decade, new trends have been emerging in order to increase theenzyme stability, the sensitivity and selectivity of the measurements, and to lower thedetection limits. These approaches are based on (i the design of novel matrices for enzymeimmobilisation, (ii new manifold configurations of the FIA system, sometimes includingminiaturisation or lab-on-chip protocols thanks to micromachining technology, (iii the useof cholinesterase enzymes either from various commercial sources or genetically modifiedwith the aim of being more sensitive, (iv the incorporation of other highly specificenzymes, such as organophosphate hydrolase (OPH or parathion hydrolase (PH and (v thecombination of different electrochemical methods of detection. This article discusses thesenovel strategies and their advantages and limitations.

  9. Towards Domain-specific Flow-based Languages

    DEFF Research Database (Denmark)

    Zarrin, Bahram; Baumeister, Hubert; Sarjoughian, Hessam S.

    2018-01-01

    describe their problems and solutions, instead of using general purpose programming languages. The goal of these languages is to improve the productivity and efficiency of the development and simulation of concurrent scientific models and systems. Moreover, they help to expose parallelism and to specify...... the concurrency within a component or across different independent components. In this paper, we introduce the concept of domain-specific flowbased languages which allows domain experts to use flow-based languages adapted to a particular problem domain. Flow-based programming is used to support concurrency, while......Due to the significant growth of the demand for data-intensive computing, in addition to the emergence of new parallel and distributed computing technologies, scientists and domain experts are leveraging languages specialized for their problem domain, i.e., domain-specific languages, to help them...

  10. A sensitive analytical procedure for monitoring acrylamide in environmental water samples by offline SPE-UPLC/MS/MS.

    Science.gov (United States)

    Togola, Anne; Coureau, Charlotte; Guezennec, Anne-Gwenaëlle; Touzé, Solène

    2015-05-01

    The presence of acrylamide in natural systems is of concern from both environmental and health points of view. We developed an accurate and robust analytical procedure (offline solid phase extraction combined with UPLC/MS/MS) with a limit of quantification (20 ng L(-1)) compatible with toxicity threshold values. The optimized (considering the nature of extraction phases, sampling volumes, and solvent of elution) solid phase extraction (SPE) was validated according to ISO Standard ISO/IEC 17025 on groundwater, surface water, and industrial process water samples. Acrylamide is highly polar, which induces a high variability during the SPE step, therefore requiring the use of C(13)-labeled acrylamide as an internal standard to guarantee the accuracy and robustness of the method (uncertainty about 25 % (k = 2) at limit of quantification level). The specificity of the method and the stability of acrylamide were studied for these environmental media, and it was shown that the method is suitable for measuring acrylamide in environmental studies.

  11. LSENS: A General Chemical Kinetics and Sensitivity Analysis Code for homogeneous gas-phase reactions. Part 1: Theory and numerical solution procedures

    Science.gov (United States)

    Radhakrishnan, Krishnan

    1994-01-01

    LSENS, the Lewis General Chemical Kinetics and Sensitivity Analysis Code, has been developed for solving complex, homogeneous, gas-phase chemical kinetics problems and contains sensitivity analysis for a variety of problems, including nonisothermal situations. This report is part 1 of a series of three reference publications that describe LENS, provide a detailed guide to its usage, and present many example problems. Part 1 derives the governing equations and describes the numerical solution procedures for the types of problems that can be solved. The accuracy and efficiency of LSENS are examined by means of various test problems, and comparisons with other methods and codes are presented. LSENS is a flexible, convenient, accurate, and efficient solver for chemical reaction problems such as static system; steady, one-dimensional, inviscid flow; reaction behind incident shock wave, including boundary layer correction; and perfectly stirred (highly backmixed) reactor. In addition, the chemical equilibrium state can be computed for the following assigned states: temperature and pressure, enthalpy and pressure, temperature and volume, and internal energy and volume. For static problems the code computes the sensitivity coefficients of the dependent variables and their temporal derivatives with respect to the initial values of the dependent variables and/or the three rate coefficient parameters of the chemical reactions.

  12. Flow-based market coupling. Stepping stone towards nodal pricing?

    International Nuclear Information System (INIS)

    Van der Welle, A.J.

    2012-07-01

    For achieving one internal energy market for electricity by 2014, market coupling is deployed to integrate national markets into regional markets and ultimately one European electricity market. The extent to which markets can be coupled depends on the available transmission capacities between countries. Since interconnections are congested from time to time, congestion management methods are deployed to divide the scarce available transmission capacities over market participants. For further optimization of the use of available transmission capacities while maintaining current security of supply levels, flow-based market coupling (FBMC) will be implemented in the CWE region by 2013. Although this is an important step forward, important hurdles for efficient congestion management remain. Hence, flow based market coupling is compared to nodal pricing, which is often considered as the most optimal solution from theoretical perspective. In the context of decarbonised power systems it is concluded that advantages of nodal pricing are likely to exceed its disadvantages, warranting further development of FBMC in the direction of nodal pricing.

  13. Flow-Based Network Analysis of the Caenorhabditis elegans Connectome.

    Science.gov (United States)

    Bacik, Karol A; Schaub, Michael T; Beguerisse-Díaz, Mariano; Billeh, Yazan N; Barahona, Mauricio

    2016-08-01

    We exploit flow propagation on the directed neuronal network of the nematode C. elegans to reveal dynamically relevant features of its connectome. We find flow-based groupings of neurons at different levels of granularity, which we relate to functional and anatomical constituents of its nervous system. A systematic in silico evaluation of the full set of single and double neuron ablations is used to identify deletions that induce the most severe disruptions of the multi-resolution flow structure. Such ablations are linked to functionally relevant neurons, and suggest potential candidates for further in vivo investigation. In addition, we use the directional patterns of incoming and outgoing network flows at all scales to identify flow profiles for the neurons in the connectome, without pre-imposing a priori categories. The four flow roles identified are linked to signal propagation motivated by biological input-response scenarios.

  14. Loss of sensitivity of immunochromatographic test (ICT) for lymphatic filariasis diagnosis in low prevalence settings: consequence in the monitoring and evaluation procedures.

    Science.gov (United States)

    Gounoue-Kamkumo, Raceline; Nana-Djeunga, Hugues C; Bopda, Jean; Akame, Julie; Tarini, Ann; Kamgno, Joseph

    2015-12-23

    Diagnostic tools for lymphatic filariasis (LF) elimination programs are useful in mapping the distribution of the disease, delineating areas where mass drug administrations (MDA) are required, and determining when to stop MDA. The prevalence and burden of LF have been drastically reduced following mass treatments, and the evaluation of the performance of circulating filarial antigen (CFA)-based assays was acknowledged to be of high interest in areas with low residual LF endemicity rates after multiple rounds of MDA. The objective of this study was therefore to evaluate the immunochromatographic test (ICT) sensitivity in low endemicity settings and, specifically, in individuals with low intensity of lymphatic filariasis infection. To perform this study, calibrated thick blood smears, ICT and Og4C3 enzyme-linked immunosorbent assay (ELISA) were carried out by night to identify Wuchereria bancrofti microfilarial and circulating filarial antigen carriers. A threshold determination assay regarding ICT and ELISA was performed using serial plasma dilutions from individuals with positive microfilarial counts. All individuals harbouring microfilariae (positive blood films) were detected by ICT and ELISA, but among individuals positive for ELISA, only 35.7 % of them were detected using ICT (Chi square: 4.57; p-value = 0.03), indicating a moderate agreement between both tests (kappa statistics = 0.49). Threshold determination analyses showed that ELISA was still positive at the last plasma dilution with negative ICT result. These findings suggest a loss of sensitivity for ICT in low endemicity settings, especially in people exhibiting low levels of circulating filarial antigen, raising serious concern regarding the monitoring and evaluation procedures in the framework of LF elimination program.

  15. Flow-based model of computer hackers' motivation.

    Science.gov (United States)

    Voiskounsky, Alexander E; Smyslova, Olga V

    2003-04-01

    Hackers' psychology, widely discussed in the media, is almost entirely unexplored by psychologists. In this study, hackers' motivation is investigated, using the flow paradigm. Flow is likely to motivate hackers, according to views expressed by researchers and by hackers themselves. Taken as granted that hackers experience flow, it was hypothesized that flow increases with the increase of hackers' competence in IT use. Self-selected subjects were recruited on specialized web sources; 457 hackers filled out a web questionnaire. Competence in IT use, specific flow experience, and demographic data were questioned. An on-line research was administered within the Russian-speaking community (though one third of Ss are non-residents of Russian Federation); since hacking seems to be international, the belief is expressed that the results are universal. The hypothesis is not confirmed: flow motivation characterizes the least and the most competent hackers, and the members of an intermediate group, that is, averagely competent Ss report the "flow crisis"-no (or less) flow experience. Two differing strategies of task choice were self-reported by Ss: a step-by-step increase of the difficulty of choices leads to a match of challenges and skills (and to preserving the flow experience); putting choices irrespective of the likelihood of solution leads to a "flow crisis." The findings give productive hints on processes of hackers' motivational development. The flow-based model of computer hackers' motivation was developed. It combines both empirically confirmed and theoretically possible ways of hackers' "professional" growth.

  16. A rapid and sensitive loop-mediated isothermal amplification procedure (LAMP) for Mycoplasma hyopneumoniae detection based on the p36 gene.

    Science.gov (United States)

    Liu, M J; Du, G M; Bai, F F; Wu, Y Z; Xiong, Q Y; Feng, Z X; Li, B; Shao, G Q

    2015-05-04

    The aim of this study was to establish a method for sensitive and rapid diagnosis of Mycoplasma hyopneumoniae in clinical specimens. To this effect, we employed three sets of primers specifically designed for amplification of nucleic acids under isothermal conditions. After optimization of reaction conditions, M. hyopneumoniae could be successfully detected at 63°C in 45 min through use of the loop-mediated isothermal amplification (LAMP) assay. A positive reaction was identified visually as white precipitate and confirmed by gel electrophoresis. The detection limit for this assay was 10 copies/μL, as observed by electrophoretic analysis. The accuracy of the LAMP reaction was confirmed by restriction endonuclease digestion as well as by direct sequencing of the amplified product. This method can specifically detect M. hyopneumoniae; other species with high homology and other bacterial and virus strains gave negative results. To test the utility of this procedure, the LAMP assay was applied to 40 clinical samples collected from swine lung tissues experimentally challenged with M. hyopneumoniae isolates, and compared to the results from a real-time polymerase chain reaction (PCR) assay. A concordance of 100% was observed between the two assays. In conclusion, the results from our study demonstrated that the LAMP assay provided a rapid reaction and was inexpensive to perform, with no need of complex instruments or systems such as Geneamp PCR. The LAMP assay may therefore be applied in routine diagnosis in the clinical laboratory and for in-field detection of M. hyopneumoniae infection.

  17. Uncertainty in sap flow-based transpiration due to xylem properties

    Science.gov (United States)

    Looker, N. T.; Hu, J.; Martin, J. T.; Jencso, K. G.

    2014-12-01

    Transpiration, the evaporative loss of water from plants through their stomata, is a key component of the terrestrial water balance, influencing streamflow as well as regional convective systems. From a plant physiological perspective, transpiration is both a means of avoiding destructive leaf temperatures through evaporative cooling and a consequence of water loss through stomatal uptake of carbon dioxide. Despite its hydrologic and ecological significance, transpiration remains a notoriously challenging process to measure in heterogeneous landscapes. Sap flow methods, which estimate transpiration by tracking the velocity of a heat pulse emitted into the tree sap stream, have proven effective for relating transpiration dynamics to climatic variables. To scale sap flow-based transpiration from the measured domain (often area) to the whole-tree level, researchers generally assume constancy of scale factors (e.g., wood thermal diffusivity (k), radial and azimuthal distributions of sap velocity, and conducting sapwood area (As)) through time, across space, and within species. For the widely used heat-ratio sap flow method (HRM), we assessed the sensitivity of transpiration estimates to uncertainty in k (a function of wood moisture content and density) and As. A sensitivity analysis informed by distributions of wood moisture content, wood density and As sampled across a gradient of water availability indicates that uncertainty in these variables can impart substantial error when scaling sap flow measurements to the whole tree. For species with variable wood properties, the application of the HRM assuming a spatially constant k or As may systematically over- or underestimate whole-tree transpiration rates, resulting in compounded error in ecosystem-scale estimates of transpiration.

  18. Emergency procedures

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Emergency Procedures: emergency equipment, emergency procedures; emergency procedure involving X-Ray equipment; emergency procedure involving radioactive sources

  19. Evidence for a relationship between VEGF and BMI independent of insulin sensitivity by glucose clamp procedure in a homogenous group healthy young men.

    Directory of Open Access Journals (Sweden)

    Michaela Loebig

    Full Text Available BACKGROUND: This is the first study to experimentally explore the direct relationship between circulating VEGF levels and body mass index (BMI as well as to unravel the role of insulin sensitivity in this context under standardized glucose clamp conditions as the methodical gold-standard. In order to control for known influencing factors such as gender, medication, and arterial hypertension, we examined a highly homogeneous group of young male subjects. Moreover, to encompass also subjects beyond the normal BMI range, low weight and obese participants were additionally included and stress hormones as a main regulator of VEGF were assessed. METHODOLOGY/PRINCIPAL FINDINGS: Under euglycemic clamp conditions, VEGF was measured in 15 normal weight (BMI 20-25 kg/m(2, 15 low weight (BMI30 kg/m(2 male subjects aged 18-30 years and the insulin sensitivity index (ISI was calculated. Since stress axis activation promotes VEGF secretion, concentrations of ACTH, cortisol, and catecholamines were monitored. Despite of comparable ACTH (P = 0.145, cortisol (P = 0.840, and norepinephrine (P = 0.065 levels, VEGF concentrations differed significantly between BMI-groups (P = 0.008 with higher concentrations in obese subjects as compared to normal weight (P = 0.061 and low weight subjects (P = 0.002. Pearson's correlation analysis revealed a positive relationship between BMI and VEGF levels (r = 0.407; P = 0.010 but no correlation of VEGF with ISI (r = 0.224; P = 0.175. CONCLUSIONS/SIGNIFICANCE: Our data demonstrate a positive correlation between concentrations of circulating VEGF levels and BMI in healthy male subjects under highly controlled conditions. This relationship which is apparently disconnected from insulin sensitivity may be part of some pathogenetic mechanisms underlying obesity and type 2 diabetes.

  20. Inverse modeling for seawater intrusion in coastal aquifers: Insights about parameter sensitivities, variances, correlations and estimation procedures derived from the Henry problem

    Science.gov (United States)

    Sanz, E.; Voss, C.I.

    2006-01-01

    Inverse modeling studies employing data collected from the classic Henry seawater intrusion problem give insight into several important aspects of inverse modeling of seawater intrusion problems and effective measurement strategies for estimation of parameters for seawater intrusion. Despite the simplicity of the Henry problem, it embodies the behavior of a typical seawater intrusion situation in a single aquifer. Data collected from the numerical problem solution are employed without added noise in order to focus on the aspects of inverse modeling strategies dictated by the physics of variable-density flow and solute transport during seawater intrusion. Covariances of model parameters that can be estimated are strongly dependent on the physics. The insights gained from this type of analysis may be directly applied to field problems in the presence of data errors, using standard inverse modeling approaches to deal with uncertainty in data. Covariance analysis of the Henry problem indicates that in order to generally reduce variance of parameter estimates, the ideal places to measure pressure are as far away from the coast as possible, at any depth, and the ideal places to measure concentration are near the bottom of the aquifer between the center of the transition zone and its inland fringe. These observations are located in and near high-sensitivity regions of system parameters, which may be identified in a sensitivity analysis with respect to several parameters. However, both the form of error distribution in the observations and the observation weights impact the spatial sensitivity distributions, and different choices for error distributions or weights can result in significantly different regions of high sensitivity. Thus, in order to design effective sampling networks, the error form and weights must be carefully considered. For the Henry problem, permeability and freshwater inflow can be estimated with low estimation variance from only pressure or only

  1. Flow-Based Systems for Rapid and High-Precision Enzyme Kinetics Studies

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Enzyme kinetics studies normally focus on the initial rate of enzymatic reaction. However, the manual operation of steps of the conventional enzyme kinetics method has some drawbacks. Errors can result from the imprecise time control and time necessary for manual changing the reaction cuvettes into and out of the detector. By using the automatic flow-based analytical systems, enzyme kinetics studies can be carried out at real-time initial rate avoiding the potential errors inherent in manual operation. Flow-based systems have been developed to provide rapid, low-volume, and high-precision analyses that effectively replace the many tedious and high volume requirements of conventional wet chemistry analyses. This article presents various arrangements of flow-based techniques and their potential use in future enzyme kinetics applications.

  2. Architectural Synthesis of Flow-Based Microfluidic Large-Scale Integration Biochips

    DEFF Research Database (Denmark)

    Minhass, Wajid Hassan; Pop, Paul; Madsen, Jan

    2012-01-01

    ,we propose a top-down architectural synthesis methodology for the flow-based biochips. Starting from a given biochemical application and a microfluidic component library, we are interested in synthesizing a biochip architecture, i.e., performing component allocation from the library based on the biochemical....... By combining several microvalves, more complex units, such as micropumps, switches, mixers, and multiplexers, can be built. The manufacturing technology, soft lithography, used for the flow-based biochips is advancing faster than Moore's law, resulting in increased architectural complexity. However...... by synthesizing architectures for real-life applications as well as synthetic benchmarks....

  3. Control Synthesis for the Flow-Based Microfluidic Large-Scale Integration Biochips

    DEFF Research Database (Denmark)

    Minhass, Wajid Hassan; Pop, Paul; Madsen, Jan

    2013-01-01

    In this paper we are interested in flow-based microfluidic biochips, which are able to integrate the necessary functions for biochemical analysis on-chip. In these chips, the flow of liquid is manipulated using integrated microvalves. By combining severalmicrovalves, more complex units, such asmi......In this paper we are interested in flow-based microfluidic biochips, which are able to integrate the necessary functions for biochemical analysis on-chip. In these chips, the flow of liquid is manipulated using integrated microvalves. By combining severalmicrovalves, more complex units...

  4. Using accelerated life testing procedures to compare the relative sensitivity of rainbow trout and the federally listed threatened bull trout to three commonly used rangeland herbicides (picloram, 2,4-D, and clopyralid).

    Science.gov (United States)

    Fairchild, James F; Allert, Ann; Sappington, Linda S; Nelson, Karen J; Valle, Janet

    2008-03-01

    We conducted 96-h static acute toxicity studies to evaluate the relative sensitivity of juveniles of the threatened bull trout (Salvelinus confluentus) and the standard cold-water surrogate rainbow trout (Onchorhyncus mykiss) to three rangeland herbicides commonly used for controlling invasive weeds in the northwestern United States. Relative species sensitivity was compared using three procedures: standard acute toxicity testing, fractional estimates of lethal concentrations, and accelerated life testing chronic estimation procedures. The acutely lethal concentrations (ALC) resulting in 50% mortality at 96 h (96-h ALC50s) were determined using linear regression and indicated that the three herbicides were toxic in the order of picloram acid > 2,4-D acid > clopyralid acid. The 96-h ALC50 values for rainbow trout were as follows: picloram, 41 mg/L; 2.4-D, 707 mg/L; and clopyralid, 700 mg/L. The 96-h ALC50 values for bull trout were as follows: picloram, 24 mg/L; 2.4-D, 398 mg/L; and clopyralid, 802 mg/L. Fractional estimates of safe concentrations, based on 5% of the 96-h ALC50, were conservative (overestimated toxicity) of regression-derived 96-h ALC5 values by an order of magnitude. Accelerated life testing procedures were used to estimate chronic lethal concentrations (CLC) resulting in 1% mortality at 30 d (30-d CLC1) for the three herbicides: picloram (1 mg/L rainbow trout, 5 mg/L bull trout), 2,4-D (56 mg/L rainbow trout, 84 mg/L bull trout), and clopyralid (477 mg/L rainbow trout; 552 mg/L bull trout). Collectively, the results indicated that the standard surrogate rainbow trout is similar in sensitivity to bull trout. Accelerated life testing procedures provided cost-effective, statistically defensible methods for estimating safe chronic concentrations (30-d CLC1s) of herbicides from acute toxicity data because they use statistical models based on the entire mortality:concentration:time data matrix.

  5. Development of substance flow based Life Cycle Assessment tool for sewage sludge treatment and disposal

    DEFF Research Database (Denmark)

    Yoshida, Hiroko; Clavreul, Julie; Scheutz, Charlotte

    Life Cycle Assessment (LCA) is a method to quantify environmental impacts of products or systems. It is often done by correlating material and energy demands with certain input characteristics. An attempt was made to evaluate the robustness of the substance flow based LCA for wastewater and sludg...

  6. Flow-Based Network Management: A Report from the IRTF NMRG Workshop

    NARCIS (Netherlands)

    de Oliveira Schmidt, R.; Sadre, R.; Hendriks, Luuk

    This is the report on the Workshop on Flow-Based Network Management, held within the 37th IRTF NMRG meeting, during IETF 93, on 24th July 2015, in Prague, Czech Republic. Following the tradition of the IRTF NMRG, the workshop focused on technologies, developments, and challenges of using flow-level

  7. Fusion of optical flow based motion pattern analysis and silhouette classification for person tracking and detection

    NARCIS (Netherlands)

    Tangelder, J.W.H.; Lebert, E.; Burghouts, G.J.; Zon, K. van; Den Uyl, M.J.

    2014-01-01

    This paper presents a novel approach to detect persons in video by combining optical flow based motion analysis and silhouette based recognition. A new fast optical flow computation method is described, and its application in a motion based analysis framework unifying human tracking and detection is

  8. Real-Time and Resilient Intrusion Detection: A Flow-Based Approach

    NARCIS (Netherlands)

    Hofstede, R.J.; Pras, Aiko

    Due to the demanding performance requirements of packet-based monitoring solutions on network equipment, flow-based intrusion detection systems will play an increasingly important role in current high-speed networks. The required technologies are already available and widely deployed: NetFlow and

  9. Synthesis of Biochemical Applications on Flow-Based Microfluidic Biochips using Constraint Programming

    DEFF Research Database (Denmark)

    Minhass, Wajid Hassan; Pop, Paul; Madsen, Jan

    2012-01-01

    Microfluidic biochips are replacing the conventional biochemical analyzers and are able to integrate the necessary functions for biochemical analysis on-chip. In this paper we are interested in flow-based biochips, in which the flow of liquid is manipulated using integrated microvalves. By combin...

  10. Flow-based vulnerability measures for network component importance: Experimentation with preparedness planning

    International Nuclear Information System (INIS)

    Nicholson, Charles D.; Barker, Kash; Ramirez-Marquez, Jose E.

    2016-01-01

    This work develops and compares several flow-based vulnerability measures to prioritize important network edges for the implementation of preparedness options. These network vulnerability measures quantify different characteristics and perspectives on enabling maximum flow, creating bottlenecks, and partitioning into cutsets, among others. The efficacy of these vulnerability measures to motivate preparedness options against experimental geographically located disruption simulations is measured. Results suggest that a weighted flow capacity rate, which accounts for both (i) the contribution of an edge to maximum network flow and (ii) the extent to which the edge is a bottleneck in the network, shows most promise across four instances of varying network sizes and densities. - Highlights: • We develop new flow-based measures of network vulnerability. • We apply these measures to determine the importance of edges after disruptions. • Networks of varying size and density are explored.

  11. An efficient flow-based botnet detection using supervised machine learning

    DEFF Research Database (Denmark)

    Stevanovic, Matija; Pedersen, Jens Myrup

    2014-01-01

    Botnet detection represents one of the most crucial prerequisites of successful botnet neutralization. This paper explores how accurate and timely detection can be achieved by using supervised machine learning as the tool of inferring about malicious botnet traffic. In order to do so, the paper...... introduces a novel flow-based detection system that relies on supervised machine learning for identifying botnet network traffic. For use in the system we consider eight highly regarded machine learning algorithms, indicating the best performing one. Furthermore, the paper evaluates how much traffic needs...... to accurately and timely detect botnet traffic using purely flow-based traffic analysis and supervised machine learning. Additionally, the results show that in order to achieve accurate detection traffic flows need to be monitored for only a limited time period and number of packets per flow. This indicates...

  12. A distributed predictive control approach for periodic flow-based networks: application to drinking water systems

    Science.gov (United States)

    Grosso, Juan M.; Ocampo-Martinez, Carlos; Puig, Vicenç

    2017-10-01

    This paper proposes a distributed model predictive control approach designed to work in a cooperative manner for controlling flow-based networks showing periodic behaviours. Under this distributed approach, local controllers cooperate in order to enhance the performance of the whole flow network avoiding the use of a coordination layer. Alternatively, controllers use both the monolithic model of the network and the given global cost function to optimise the control inputs of the local controllers but taking into account the effect of their decisions over the remainder subsystems conforming the entire network. In this sense, a global (all-to-all) communication strategy is considered. Although the Pareto optimality cannot be reached due to the existence of non-sparse coupling constraints, the asymptotic convergence to a Nash equilibrium is guaranteed. The resultant strategy is tested and its effectiveness is shown when applied to a large-scale complex flow-based network: the Barcelona drinking water supply system.

  13. Sensitivity and uncertainty analysis

    CERN Document Server

    Cacuci, Dan G; Navon, Ionel Michael

    2005-01-01

    As computer-assisted modeling and analysis of physical processes have continued to grow and diversify, sensitivity and uncertainty analyses have become indispensable scientific tools. Sensitivity and Uncertainty Analysis. Volume I: Theory focused on the mathematical underpinnings of two important methods for such analyses: the Adjoint Sensitivity Analysis Procedure and the Global Adjoint Sensitivity Analysis Procedure. This volume concentrates on the practical aspects of performing these analyses for large-scale systems. The applications addressed include two-phase flow problems, a radiative c

  14. Quantization Procedures

    International Nuclear Information System (INIS)

    Cabrera, J. A.; Martin, R.

    1976-01-01

    We present in this work a review of the conventional quantization procedure, the proposed by I.E. Segal and a new quantization procedure similar to this one for use in non linear problems. We apply this quantization procedures to different potentials and we obtain the appropriate equations of motion. It is shown that for the linear case the three procedures exposed are equivalent but for the non linear cases we obtain different equations of motion and different energy spectra. (Author) 16 refs

  15. Risk of bacterial cross infection associated with inspiration through flow-based spirometers.

    Science.gov (United States)

    Bracci, Massimo; Strafella, Elisabetta; Croce, Nicola; Staffolani, Sara; Carducci, Annalaura; Verani, Marco; Valentino, Matteo; Santarelli, Lory

    2011-02-01

    Bacterial contamination of spirometers has been documented in water-sealed devices, mouthpieces, and connection tubes. Little information is available about bacterial contamination of flow-based apparatuses such as turbine-type spirometers and pneumotachographs. Inspiration through contaminated equipment is a potential source of cross infection. To investigate bacteria mobilization (ie, bacteria detachment and aerosolization from the instrument) during routine spirometric testing, 2 types of flow-based spirometers were used. Bacteria mobilization during artificial inspiration through in-line filters or cardboard mouthpieces was evaluated. Nine hundred workers undergoing periodic spirometric testing were enrolled at the occupational physician office in 30 sessions of 30 subjects each. The participants were asked to perform a forced vital capacity test in a turbine-type spirometer and in an unheated pneumotachograph fitted with disposable in-line filters or cardboard mouthpieces. To evaluate bacterial mobilization, an artificial inspiration was performed and bacterial growth determined. The bacterial growth analysis was assessed after the first and the thirtieth spirometric tests of each session without disinfecting the instruments between tests. In addition, instrument bacterial contamination was evaluated. No significant bacterial mobilization and instrument contamination were found in spirometric tests executed with in-line filters. Conversely, a significant bacterial mobilization and instrument contamination were observed in tests performed with cardboard mouthpieces. Differences between the 2 spirometers were not significant. In-line filters may effectively reduce the risk of bacterial cross infection. Inspiration through flow-based spirometers fitted with disposable cardboard mouthpieces is completely safe when combined with spirometer disinfection/sterilization between subjects. Copyright © 2011 Association for Professionals in Infection Control and

  16. A two-stage flow-based intrusion detection model for next-generation networks.

    Science.gov (United States)

    Umer, Muhammad Fahad; Sher, Muhammad; Bi, Yaxin

    2018-01-01

    The next-generation network provides state-of-the-art access-independent services over converged mobile and fixed networks. Security in the converged network environment is a major challenge. Traditional packet and protocol-based intrusion detection techniques cannot be used in next-generation networks due to slow throughput, low accuracy and their inability to inspect encrypted payload. An alternative solution for protection of next-generation networks is to use network flow records for detection of malicious activity in the network traffic. The network flow records are independent of access networks and user applications. In this paper, we propose a two-stage flow-based intrusion detection system for next-generation networks. The first stage uses an enhanced unsupervised one-class support vector machine which separates malicious flows from normal network traffic. The second stage uses a self-organizing map which automatically groups malicious flows into different alert clusters. We validated the proposed approach on two flow-based datasets and obtained promising results.

  17. An Analytical Cost Estimation Procedure

    National Research Council Canada - National Science Library

    Jayachandran, Toke

    1999-01-01

    Analytical procedures that can be used to do a sensitivity analysis of a cost estimate, and to perform tradeoffs to identify input values that can reduce the total cost of a project, are described in the report...

  18. Environmental procedures

    International Nuclear Information System (INIS)

    1992-01-01

    The European Bank has pledged in its Agreement to place environmental management at the forefront of its operations to promote sustainable economic development in central and eastern Europe. The Bank's environmental policy is set out in the document titled, Environmental Management: The Bank's Policy Approach. This document, Environmental Procedures, presents the procedures which the European Bank has adopted to implement this policy approach with respect to its operations. The environmental procedures aim to: ensure that throughout the project approval process, those in positions of responsibility for approving projects are aware of the environmental implications of the project, and can take these into account when making decisions; avoid potential liabilities that could undermine the success of a project for its sponsors and the Bank; ensure that environmental costs are estimated along with other costs and liabilities; and identify opportunities for environmental enhancement associated with projects. The review of environmental aspects of projects is conducted by many Bank staff members throughout the project's life. This document defines the responsibilities of the people and groups involved in implementing the environmental procedures. Annexes contain Environmental Management: The Bank's Policy Approach, examples of environmental documentation for the project file and other ancillary information

  19. Transformation of Commercial Flows into Physical Flows of Electricity – Flow Based Method

    Directory of Open Access Journals (Sweden)

    M. Adamec

    2009-01-01

    Full Text Available We are witnesses of large – scale electricity transport between European countries under the umbrella of the UCTE organization. This is due to the inabilyof generators to satisfy the growing consumption in some regions. In this content, we distinguish between two types of flow. The first type is physical flow, which causes costs in the transmission grid, whilst the second type is commercial flow, which provides revenues for the market participants. The old methods for allocating transfer capacity fail to take this duality into account. The old methods that allocate transmission border capacity to “virtual” commercial flows which, in fact, will not flow over this border, do not lead to optimal allocation. Some flows are uselessly rejected and conversely, some accepted flows can cause congestion on another border. The Flow Based Allocation method (FBA is a method which aims to solve this problem.Another goal of FBA is to ensure sustainable development of expansion of transmission capacity. Transmission capacity is important, because it represents a way to establish better transmission system stability, and it provides a distribution channel for electricity to customers abroad. For optimal development, it is necessary to ensure the right division of revenue allocation among the market participants.This paper contains a brief description of the FBA method. Problems of revenue maximization and optimal revenue distribution are mentioned. 

  20. FLOW-BASED NETWORK MEASURES OF BRAIN CONNECTIVITY IN ALZHEIMER'S DISEASE.

    Science.gov (United States)

    Prasad, Gautam; Joshi, Shantanu H; Nir, Talia M; Toga, Arthur W; Thompson, Paul M

    2013-01-01

    We present a new flow-based method for modeling brain structural connectivity. The method uses a modified maximum-flow algorithm that is robust to noise in the diffusion data and guided by biologically viable pathways and structure of the brain. A flow network is first created using a lattice graph by connecting all lattice points (voxel centers) to all their neighbors by edges. Edge weights are based on the orientation distribution function (ODF) value in the direction of the edge. The maximum-flow is computed based on this flow graph using the flow or the capacity between each region of interest (ROI) pair by following the connected tractography fibers projected onto the flow graph edges. Network measures such as global efficiency, transitivity, path length, mean degree, density, modularity, small world, and assortativity are computed from the flow connectivity matrix. We applied our method to diffusion-weighted images (DWIs) from 110 subjects (28 normal elderly, 56 with early and 11 with late mild cognitive impairment, and 15 with AD) and segmented co-registered anatomical MRIs into cortical regions. Experimental results showed better performance compared to the standard fiber-counting methods when distinguishing Alzheimer's disease from normal aging.

  1. A novel flow-based parameter of collateral function assessed by intracoronary thermodilution.

    Science.gov (United States)

    Lindner, Markus; Felix, Stephan B; Empen, Klaus; Reffelmann, Thorsten

    2014-04-01

    Currently, many methods for quantitation of coronary collateral function are based on intracoronary pressure measurements distal of an occluded balloon, which do not fully account for the dynamic nature of collateral flow. Therefore, a flow-based parameter of coronary collateral function based upon principles of thermodilution was evaluated. In 26 patients with a high-grade coronary artery stenosis, intracoronary hemodynamics were analyzed by the RadiAnalyzer system (St Jude Medical), including fractional flow reserve (FFR), index of microcirculatory resistance (IMR), and the pressure-based collateral flow index (CFI) during balloon occlusion and hyperemia (intravenous adenosine). Moreover, immediately after an intracoronary bolus of room-temperature saline, the balloon was occluded and the intracoronary temperature distal to the balloon was analyzed over time. The slope of the temperature-time curve was calculated after logarithmic transformation as an index of collateral blood flow (CBFI). The coefficient of variation between two measurements of CBFI amounted to 11 ± 2%. In patients with CFI ≥0.25, CBFI amounted to 0.55 ± 0.09, whereas in those with CFI function, and should be evaluated in further studies.

  2. Radiochemical procedures

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1982-01-01

    The modern counting instrumentation has largely obviated the need for separation processes in the radiochemical analysis but problems in low-level radioactivity measurement, environmental-type analyses, and special situations caused in the last years a renaissance of the need for separation techniques. Most of the radiochemical procedures, based on the classic works of the Manhattan Project chemists of the 1940's, were published in the National Nuclear Energy Series (NNES). Improvements such as new solvent extraction and ion exchange separations have been added to these methods throughout the years. Recently the Los Alamos Group have reissued their collected Radiochemical Procedures containing a short summary and review of basic inorganic chemistry - 'Chemistry of the Elements on the Basis of Electronic Configuration'. (A.L.)

  3. Exploring Flow Procedures for Diazonium Formation

    Directory of Open Access Journals (Sweden)

    Te Hu

    2016-07-01

    Full Text Available The synthesis of diazonium salts is historically an important transformation extensively utilized in dye manufacture. However the highly reactive nature of the diazonium functionality has additionally led to the development of many new reactions including several carbon-carbon bond forming processes. It is therefore highly desirable to determine optimum conditions for the formation of diazonium compounds utilizing the latest processing tools such as flow chemistry to take advantage of the increased safety and continuous manufacturing capabilities. Herein we report a series of flow-based procedures to prepare diazonium salts for subsequent in-situ consumption.

  4. Exploring Flow Procedures for Diazonium Formation.

    Science.gov (United States)

    Hu, Te; Baxendale, Ian R; Baumann, Marcus

    2016-07-14

    The synthesis of diazonium salts is historically an important transformation extensively utilized in dye manufacture. However the highly reactive nature of the diazonium functionality has additionally led to the development of many new reactions including several carbon-carbon bond forming processes. It is therefore highly desirable to determine optimum conditions for the formation of diazonium compounds utilizing the latest processing tools such as flow chemistry to take advantage of the increased safety and continuous manufacturing capabilities. Herein we report a series of flow-based procedures to prepare diazonium salts for subsequent in-situ consumption.

  5. A lightweight, flow-based toolkit for parallel and distributed bioinformatics pipelines

    Directory of Open Access Journals (Sweden)

    Cieślik Marcin

    2011-02-01

    Full Text Available Abstract Background Bioinformatic analyses typically proceed as chains of data-processing tasks. A pipeline, or 'workflow', is a well-defined protocol, with a specific structure defined by the topology of data-flow interdependencies, and a particular functionality arising from the data transformations applied at each step. In computer science, the dataflow programming (DFP paradigm defines software systems constructed in this manner, as networks of message-passing components. Thus, bioinformatic workflows can be naturally mapped onto DFP concepts. Results To enable the flexible creation and execution of bioinformatics dataflows, we have written a modular framework for parallel pipelines in Python ('PaPy'. A PaPy workflow is created from re-usable components connected by data-pipes into a directed acyclic graph, which together define nested higher-order map functions. The successive functional transformations of input data are evaluated on flexibly pooled compute resources, either local or remote. Input items are processed in batches of adjustable size, all flowing one to tune the trade-off between parallelism and lazy-evaluation (memory consumption. An add-on module ('NuBio' facilitates the creation of bioinformatics workflows by providing domain specific data-containers (e.g., for biomolecular sequences, alignments, structures and functionality (e.g., to parse/write standard file formats. Conclusions PaPy offers a modular framework for the creation and deployment of parallel and distributed data-processing workflows. Pipelines derive their functionality from user-written, data-coupled components, so PaPy also can be viewed as a lightweight toolkit for extensible, flow-based bioinformatics data-processing. The simplicity and flexibility of distributed PaPy pipelines may help users bridge the gap between traditional desktop/workstation and grid computing. PaPy is freely distributed as open-source Python code at http://muralab.org/PaPy, and

  6. Sensitivity analysis

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003741.htm Sensitivity analysis To use the sharing features on this page, please enable JavaScript. Sensitivity analysis determines the effectiveness of antibiotics against microorganisms (germs) ...

  7. Architecture Synthesis for Cost-Constrained Fault-Tolerant Flow-based Biochips

    DEFF Research Database (Denmark)

    Eskesen, Morten Chabert; Pop, Paul; Potluri, Seetal

    2016-01-01

    . This increase in fabrication complexity has led to an increase in defect rates during the manufacturing, thereby motivating the need to improve the yield, by designing these biochips such that they are fault tolerant. We propose an approach based on a Greedy Randomized Adaptive Search Procedure (GRASP...

  8. Pretreatment procedures

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    It is frequently in the patient's best interest that radiation treatments are initiated soon after the decision to treat is made. However, it is essential to good radiation therapy that the patient's treatment course be planned and beam-modifying devices be fabricated with utmost care prior to treatment. The objectives of the treatment, along with the treatment parameters and techniques necessary to achieve these objectives, must be discussed prior to initiating planning procedures. Determination of the target volume is made by the radiation oncologist; this is based on knowledge of the history of the tumor, the patterns of spread of the disease, and on diagnostic findings during the work-up of each patient. It is then necessary to obtain several measurements of the patient and also to identify the position of the target volume and of adjacent normal organs with respect to known external skin marks before the actual treatment planning is begun. Such localization can be done through several methods. The two most commonly used methods are radiographic and computed tomography (CT), both of which are discussed in this chapter. The measurements often include contours of the patient's external surface, usually in the axial plane of the central axis of the beam, and often in multiple levels within the region to be treated. Three dimensional localization and treatment planning requires thorough understanding of geometry as well as of patient positioning and immobilization. This chapter attempts to clarify some of these complicated but essential preparations for treatment

  9. Microwave-Assisted Sample Treatment in a Fully Automated Flow-Based Instrument: Oxidation of Reduced Technetium Species in the Analysis of Total Technetium-99 in Caustic Aged Nuclear Waste Samples

    International Nuclear Information System (INIS)

    Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.

    2004-01-01

    An automated flow-based instrument for microwave-assisted treatment of liquid samples has been developed and characterized. The instrument utilizes a flow-through reaction vessel design that facilitates the addition of multiple reagents during sample treatment, removal of the gaseous reaction products, and enables quantitative removal of liquids from the reaction vessel for carryover-free operations. Matrix modification and speciation control chemistries that are required for the radiochemical determination of total 99Tc in caustic aged nuclear waste samples have been investigated. A rapid and quantitative oxidation procedure using peroxydisulfate in acidic solution was developed to convert reduced technetium species to pertechnetate in samples with high content of reducing organics. The effectiveness of the automated sample treatment procedures has been validated in the radiochemical analysis of total 99Tc in caustic aged nuclear waste matrixes from the Hanford site

  10. Allergic sensitization

    DEFF Research Database (Denmark)

    van Ree, Ronald; Hummelshøj, Lone; Plantinga, Maud

    2014-01-01

    Allergic sensitization is the outcome of a complex interplay between the allergen and the host in a given environmental context. The first barrier encountered by an allergen on its way to sensitization is the mucosal epithelial layer. Allergic inflammatory diseases are accompanied by increased pe...

  11. Climate Sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Lindzen, Richard [M.I.T.

    2011-11-09

    Warming observed thus far is entirely consistent with low climate sensitivity. However, the result is ambiguous because the sources of climate change are numerous and poorly specified. Model predictions of substantial warming aredependent on positive feedbacks associated with upper level water vapor and clouds, but models are notably inadequate in dealing with clouds and the impacts of clouds and water vapor are intimately intertwined. Various approaches to measuring sensitivity based on the physics of the feedbacks will be described. The results thus far point to negative feedbacks. Problems with these approaches as well as problems with the concept of climate sensitivity will be described.

  12. Radioecological sensitivity

    International Nuclear Information System (INIS)

    Howard, Brenda J.; Strand, Per; Assimakopoulos, Panayotis

    2003-01-01

    After the release of radionuclide into the environment it is important to be able to readily identify major routes of radiation exposure, the most highly exposed individuals or populations and the geographical areas of most concern. Radioecological sensitivity can be broadly defined as the extent to which an ecosystem contributes to an enhanced radiation exposure to Man and biota. Radioecological sensitivity analysis integrates current knowledge on pathways, spatially attributes the underlying processes determining transfer and thereby identifies the most radioecologically sensitive areas leading to high radiation exposure. This identifies where high exposure may occur and why. A framework for the estimation of radioecological sensitivity with respect to humans is proposed and the various indicators by which it can be considered have been identified. These are (1) aggregated transfer coefficients (Tag), (2) action (and critical) loads, (3) fluxes and (4) individual exposure of humans. The importance of spatial and temporal consideration of all these outputs is emphasized. Information on the extent of radionuclide transfer and exposure to humans at different spatial scales is needed to reflect the spatial differences which can occur. Single values for large areas, such as countries, can often mask large variation within the country. Similarly, the relative importance of different pathways can change with time and therefore assessments of radiological sensitivity are needed over different time periods after contamination. Radioecological sensitivity analysis can be used in radiation protection, nuclear safety and emergency preparedness when there is a need to identify areas that have the potential of being of particular concern from a risk perspective. Prior identification of radioecologically sensitive areas and exposed individuals improve the focus of emergency preparedness and planning, and contribute to environmental impact assessment for future facilities. The

  13. Fully automatic flow-based device for monitoring of drug permeation across a cell monolayer.

    Science.gov (United States)

    Zelená, Lucie; Marques, Sara S; Segundo, Marcela A; Miró, Manuel; Pávek, Petr; Sklenářová, Hana; Solich, Petr

    2016-01-01

    A novel flow-programming setup based on the sequential injection principle is herein proposed for on-line monitoring of temporal events in cell permeation studies. The permeation unit consists of a Franz cell with its basolateral compartment mixed under mechanical agitation and thermostated at 37 °C. The apical compartment is replaced by commercially available Transwell inserts with a precultivated cell monolayer. The transport of drug substances across epithelial cells genetically modified with the P-glycoprotein membrane transporter (MDCKII-MDR1) is monitored on-line using rhodamine 123 as a fluorescent marker. The permeation kinetics of the marker is obtained in a fully automated mode by sampling minute volumes of solution from the basolateral compartment in short intervals (10 min) up to 4 h. The effect of a P-glycoprotein transporter inhibitor, verapamil as a model drug, on the efficiency of the marker transport across the cell monolayer is thoroughly investigated. The analytical features of the proposed flow method for cell permeation studies in real time are critically compared against conventional batch-wise procedures and microfluidic devices.

  14. A Laminar Flow-Based Microfluidic Tesla Pump via Lithography Enabled 3D Printing.

    Science.gov (United States)

    Habhab, Mohammed-Baker; Ismail, Tania; Lo, Joe Fujiou

    2016-11-23

    Tesla turbine and its applications in power generation and fluid flow were demonstrated by Nicholas Tesla in 1913. However, its real-world implementations were limited by the difficulty to maintain laminar flow between rotor disks, transient efficiencies during rotor acceleration, and the lack of other applications that fully utilize the continuous flow outputs. All of the aforementioned limits of Tesla turbines can be addressed by scaling to the microfluidic flow regime. Demonstrated here is a microscale Tesla pump designed and fabricated using a Digital Light Processing (DLP) based 3D printer with 43 µm lateral and 30 µm thickness resolutions. The miniaturized pump is characterized by low Reynolds number of 1000 and a flow rate of up to 12.6 mL/min at 1200 rpm, unloaded. It is capable of driving a mixer network to generate microfluidic gradient. The continuous, laminar flow from Tesla turbines is well-suited to the needs of flow-sensitive microfluidics, where the integrated pump will enable numerous compact lab-on-a-chip applications.

  15. A Laminar Flow-Based Microfluidic Tesla Pump via Lithography Enabled 3D Printing

    Directory of Open Access Journals (Sweden)

    Mohammed-Baker Habhab

    2016-11-01

    Full Text Available Tesla turbine and its applications in power generation and fluid flow were demonstrated by Nicholas Tesla in 1913. However, its real-world implementations were limited by the difficulty to maintain laminar flow between rotor disks, transient efficiencies during rotor acceleration, and the lack of other applications that fully utilize the continuous flow outputs. All of the aforementioned limits of Tesla turbines can be addressed by scaling to the microfluidic flow regime. Demonstrated here is a microscale Tesla pump designed and fabricated using a Digital Light Processing (DLP based 3D printer with 43 µm lateral and 30 µm thickness resolutions. The miniaturized pump is characterized by low Reynolds number of 1000 and a flow rate of up to 12.6 mL/min at 1200 rpm, unloaded. It is capable of driving a mixer network to generate microfluidic gradient. The continuous, laminar flow from Tesla turbines is well-suited to the needs of flow-sensitive microfluidics, where the integrated pump will enable numerous compact lab-on-a-chip applications.

  16. The risk of active sensitization to PPD.

    NARCIS (Netherlands)

    Devos, S.A.; Valk, P.G.M. van der

    2001-01-01

    Para-phenylenediamine (PPD) and para-aminoazobenzene are strong sensitizers. By the patch test procedure, the patient may be sensitized to these agents. Combined testing of para-compounds may increase the risk of active sensitization. We studied the % of positive patch test reactions and their

  17. Sensitivities of ionic explosives

    Science.gov (United States)

    Politzer, Peter; Lane, Pat; Murray, Jane S.

    2017-03-01

    We have investigated the relevance for ionic explosive sensitivity of three factors that have been demonstrated to be related to the sensitivities of molecular explosives. These are (1) the maximum available heat of detonation, (2) the amount of free space per molecule (or per formula unit) in the crystal lattice and (3) specific features of the electrostatic potential on the molecular or ionic surface. We find that for ionic explosives, just as for molecular ones, there is an overall tendency for impact sensitivity to increase as the maximum detonation heat release is greater. This means that the usual emphasis upon designing explosives with large heats of detonation needs to be tempered somewhat. We also show that a moderate detonation heat release does not preclude a high level of detonation performance for ionic explosives, as was already demonstrated for molecular ones. Relating the free space per formula unit to sensitivity may require a modified procedure for ionic explosives; this will continue to be investigated. Finally, an encouraging start has been made in linking impact sensitivities to the electrostatic potentials on ionic surfaces, although limited so far to ammonium salts.

  18. Optic flow-based collision-free strategies: From insects to robots.

    Science.gov (United States)

    Serres, Julien R; Ruffier, Franck

    2017-09-01

    Flying insects are able to fly smartly in an unpredictable environment. It has been found that flying insects have smart neurons inside their tiny brains that are sensitive to visual motion also called optic flow. Consequently, flying insects rely mainly on visual motion during their flight maneuvers such as: takeoff or landing, terrain following, tunnel crossing, lateral and frontal obstacle avoidance, and adjusting flight speed in a cluttered environment. Optic flow can be defined as the vector field of the apparent motion of objects, surfaces, and edges in a visual scene generated by the relative motion between an observer (an eye or a camera) and the scene. Translational optic flow is particularly interesting for short-range navigation because it depends on the ratio between (i) the relative linear speed of the visual scene with respect to the observer and (ii) the distance of the observer from obstacles in the surrounding environment without any direct measurement of either speed or distance. In flying insects, roll stabilization reflex and yaw saccades attenuate any rotation at the eye level in roll and yaw respectively (i.e. to cancel any rotational optic flow) in order to ensure pure translational optic flow between two successive saccades. Our survey focuses on feedback-loops which use the translational optic flow that insects employ for collision-free navigation. Optic flow is likely, over the next decade to be one of the most important visual cues that can explain flying insects' behaviors for short-range navigation maneuvers in complex tunnels. Conversely, the biorobotic approach can therefore help to develop innovative flight control systems for flying robots with the aim of mimicking flying insects' abilities and better understanding their flight. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Sensitive Media

    Directory of Open Access Journals (Sweden)

    Malinowska Anna

    2017-12-01

    Full Text Available The paper engages with what we refer to as “sensitive media,” a concept associated with developments in the overall media environment, our relationships with media devices, and the quality of the media themselves. Those developments point to the increasing emotionality of the media world and its infrastructures. Mapping the trajectories of technological development and impact that the newer media exert on human condition, our analysis touches upon various forms of emergent affect, emotion, and feeling in order to trace the histories and motivations of the sensitization of “the media things” as well as the redefinition of our affective and emotional experiences through technologies that themselves “feel.”

  20. Sensitive innovation

    DEFF Research Database (Denmark)

    Søndergaard, Katia Dupret

    Present paper discusses sources of innovation as heterogenic and at times intangible processes. Arguing for heterogeneity and intangibility as sources of innovation originates from a theoretical reading in STS and ANT studies (e.g. Callon 1986, Latour 1996, Mol 2002, Pols 2005) and from field work...... in the area of mental health (Dupret Søndergaard 2009, 2010). The concept of sensitive innovation is developed to capture and conceptualise exactly those heterogenic and intangible processes. Sensitive innovation is therefore primarily a way to understand innovative sources that can be......, but are not necessarily, recognized and acknowledged as such in the outer organisational culture or by management. The added value that qualifies these processes to be defined as “innovative” are thus argued for along different lines than in more traditional innovation studies (e.g. studies that build on the classic...

  1. Towards agile large-scale predictive modelling in drug discovery with flow-based programming design principles.

    Science.gov (United States)

    Lampa, Samuel; Alvarsson, Jonathan; Spjuth, Ola

    2016-01-01

    Predictive modelling in drug discovery is challenging to automate as it often contains multiple analysis steps and might involve cross-validation and parameter tuning that create complex dependencies between tasks. With large-scale data or when using computationally demanding modelling methods, e-infrastructures such as high-performance or cloud computing are required, adding to the existing challenges of fault-tolerant automation. Workflow management systems can aid in many of these challenges, but the currently available systems are lacking in the functionality needed to enable agile and flexible predictive modelling. We here present an approach inspired by elements of the flow-based programming paradigm, implemented as an extension of the Luigi system which we name SciLuigi. We also discuss the experiences from using the approach when modelling a large set of biochemical interactions using a shared computer cluster.Graphical abstract.

  2. System-Level Modeling and Synthesis Techniques for Flow-Based Microfluidic Very Large Scale Integration Biochips

    DEFF Research Database (Denmark)

    Minhass, Wajid Hassan

    Microfluidic biochips integrate different biochemical analysis functionalities on-chip and offer several advantages over the conventional biochemical laboratories. In this thesis, we focus on the flow-based biochips. The basic building block of such a chip is a valve which can be fabricated at very...... propose a framework for mapping the biochemical applications onto the mVLSI biochips, binding and scheduling the operations and performing fluid routing. A control synthesis framework for determining the exact valve activation sequence required to execute the application is also proposed. In order...... to reduce the macro-assembly around the chip and enhance chip scalability, we propose an approach for the biochip pin count minimization. We also propose a throughput maximization scheme for the cell culture mVLSI biochips, saving time and reducing costs. We have extensively evaluated the proposed...

  3. HASL procedures manual

    International Nuclear Information System (INIS)

    Harley, J.H.

    1977-08-01

    Additions and corrections to the following sections of the HASL Procedures Manual are provided: General, Sampling, Field Measurements; General Analytical Chemistry, Chemical Procedures, Data Section, and Specifications

  4. Sensitive Ceramics

    DEFF Research Database (Denmark)

    2014-01-01

    Sensitive Ceramics is showing an interactive digital design tool for designing wall like composition with 3d ceramics. The experiment is working on two levels. One which has to do with designing compositions and patterns in a virtual 3d universe based on a digital dynamic system that responds on ...... with realizing the modules in ceramics by 3d printing directly in porcelain with a RapMan printer that coils up the 3d shape in layers. Finally the ceramic modules are mounted in a laser cut board that reflects the captured composition of the movement of the hands....

  5. Flow-based market coupling. A joint ETSO-EuroPEX proposal for cross-border congestion management and integration of electricity markets in Europe. Interim report

    International Nuclear Information System (INIS)

    2004-09-01

    ETSO and EuroPEX have previously published separate proposals for congestion management and market operation across borders in Europe. ETSO has described a 'vision' in which Transmission System Operators (TSOs) would support trade between a variety of different markets by taking explicit account of the physical flows of electricity between them ('flow-based modelling'). EuroPEX has described 'Decentralized Market Coupling' as a method to integrate regional energy markets with cross-border congestion management. In most respects the ETSO and EuroPEX proposals are consistent and complementary. In particular, both organisations agree that market-based congestion management mechanisms should be used at all borders wherever possible, and that they should be co-ordinated to take account of the interdependence of physical flows. Furthermore, both ETSO and EuroPEX recognize that integrated markets are in general more efficient than separate ones, but accept that coupling of regional markets is the most realistic way of achieving efficiency benefits in the short and medium term. The commonalty between the ETSO and EuroPEX proposals has been noted by the 'Florence' Regulators' Forum, which has therefore encouraged ETSO and EuroPEX to work together to develop joint proposals. They have responded by setting up a Joint Working Group, which has produced this report to describe its progress to date. Currently, there exists a wide variety of organisational structures and operational practices in Europe. Consequently, ETSO and EuroPEX agreed at an early stage that, although a joint vision of a flow-based market coupling (FMC) model should be developed, it was equally important to identify how the current arrangements could evolve towards it in a series of practical steps. The work is not yet complete. This is an interim report designed to expose ideas at an early stage to enable Regulators, Users and other interested parties to join the debate and provide feedback. In particular

  6. Flow-based market coupling. A joint ETSO-EuroPEX proposal for cross-border congestion management and integration of electricity markets in Europe. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-09-01

    ETSO and EuroPEX have previously published separate proposals for congestion management and market operation across borders in Europe. ETSO has described a 'vision' in which Transmission System Operators (TSOs) would support trade between a variety of different markets by taking explicit account of the physical flows of electricity between them ('flow-based modelling'). EuroPEX has described 'Decentralized Market Coupling' as a method to integrate regional energy markets with cross-border congestion management. In most respects the ETSO and EuroPEX proposals are consistent and complementary. In particular, both organisations agree that market-based congestion management mechanisms should be used at all borders wherever possible, and that they should be co-ordinated to take account of the interdependence of physical flows. Furthermore, both ETSO and EuroPEX recognize that integrated markets are in general more efficient than separate ones, but accept that coupling of regional markets is the most realistic way of achieving efficiency benefits in the short and medium term. The commonalty between the ETSO and EuroPEX proposals has been noted by the 'Florence' Regulators' Forum, which has therefore encouraged ETSO and EuroPEX to work together to develop joint proposals. They have responded by setting up a Joint Working Group, which has produced this report to describe its progress to date. Currently, there exists a wide variety of organisational structures and operational practices in Europe. Consequently, ETSO and EuroPEX agreed at an early stage that, although a joint vision of a flow-based market coupling (FMC) model should be developed, it was equally important to identify how the current arrangements could evolve towards it in a series of practical steps. The work is not yet complete. This is an interim report designed to expose ideas at an early stage to enable Regulators, Users and other interested parties to join the

  7. Computer assisted procedure maintenance

    International Nuclear Information System (INIS)

    Bisio, R.; Hulsund, J. E.; Nilsen, S.

    2004-04-01

    The maintenance of operating procedures in a NPP is a tedious and complicated task. Through the whole life cycle of the procedures they will be dynamic, 'living' documents. Several aspects of the procedure must be considered in a revision process. Pertinent details and attributes of the procedure must be checked. An organizational structure must be created and responsibilities allotted for drafting, revising, reviewing and publishing procedures. Available powerful computer technology provides solutions within document management and computerisation of procedures. These solutions can also support the maintenance of procedures. Not all parts of the procedure life cycle are equally amenable to computerized support. This report looks at the procedure life cycle in todays NPPs and discusses the possibilities associated with introduction of computer technology to assist the maintenance of procedures. (Author)

  8. Multiple predictor smoothing methods for sensitivity analysis

    International Nuclear Information System (INIS)

    Helton, Jon Craig; Storlie, Curtis B.

    2006-01-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described: (1) locally weighted regression (LOESS), (2) additive models, (3) projection pursuit regression, and (4) recursive partitioning regression. The indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present

  9. Multiple predictor smoothing methods for sensitivity analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Helton, Jon Craig; Storlie, Curtis B.

    2006-08-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described: (1) locally weighted regression (LOESS), (2) additive models, (3) projection pursuit regression, and (4) recursive partitioning regression. The indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present.

  10. Analytical procedures. Pt. 4

    International Nuclear Information System (INIS)

    Rackwitz, R.

    1985-01-01

    The semi-analytical procedures are summarized under the heading 'first or second-order reliability method'. The asymptotic aggravation of the theory was repeatedly hinted at. In supporting structures the probability of outage of components always is also a function of the condition of all other components. It depends moreover on the stress affecting mostly all components. This fact causes a marked reduction of the effect of redundant component arrangements in the system. It moreover requires very special formulations. Although theoretically interesting and practically important developments will leave their mark on the further progress of the theory, the statements obtained by those approaches will continue to depend on how closely the chosen physical relationships and stoachstic models can come to the scatter quantities. Sensitivity studies show that these are partly aspects of substantially higher importance with a view to decision criteria than the refinement of the (probabilistic) method. Questions of relevance and reliability of data and their adequate treatment in reliability analyses seem to rank higher in order of sequence than exaggerated demands on methodics. (orig./HP) [de

  11. Windowed multipole sensitivity to target accuracy of the optimization procedure

    International Nuclear Information System (INIS)

    Josey, Colin; Forget, Benoit; Smith, Kord

    2015-01-01

    This paper compares the accuracy of the windowed multipole direct Doppler broadening method to that of the ENDF-B/VII.1 libraries that come with MCNP6. Various windowed multipole libraries were generated with different maximum allowed relative errors. Then, the libraries were compared to the MCNP6 data via resonance integral and through single assembly Monte Carlo analysis. Since the windowed multipole uses resonance parameters, resonance integrals are only affected by the number of resonances included in the library and not by the order of the background fitting function. The relative performance of each library with varying maximum allowed error was evaluated. It was found that setting a maximum target relative error of 0.1% in the library provided highly accurate data that closely matches the MCNP6 data for all temperatures of interest, while still having suitable computational performance. Additionally, a library with a maximum relative error of 1% also provided reasonable accuracy on eigenvalue and reaction rates with a noticeable improvement on performance, but with a few statistically significant differences with the MCNP6 data. (author)

  12. Computerized procedures system

    Science.gov (United States)

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  13. A flow-based methodology for the calculation of TSO to TSO compensations for cross-border flows

    International Nuclear Information System (INIS)

    Glavitsch, H.; Andersson, G.; Lekane, Th.; Marien, A.; Mees, E.; Naef, U.

    2004-01-01

    In the context of the development of the European internal electricity market, several methods for the tarification of cross-border flows have been proposed. This paper presents a flow-based method for the calculation of TSO to TSO compensations for cross-border flows. The basic principle of this approach is the allocation of the costs of cross-border flows to the TSOs who are responsible for these flows. This method is cost reflective, non-transaction based and compatible with domestic tariffs. It can be applied when limited data are available. Each internal transmission network is then modelled as an aggregated node, called 'supernode', and the European network is synthesized by a graph of supernodes and arcs, each arc representing all cross-border lines between two adjacent countries. When detailed data are available, the proposed methodology is also applicable to all the nodes and lines of the transmission network. Costs associated with flows transiting through supernodes or network elements are forwarded through the network in a way reflecting how the flows make use of the network. The costs can be charged either towards loads and exports or towards generations and imports. Combination of the two charging directions can also be considered. (author)

  14. Human factoring administrative procedures

    International Nuclear Information System (INIS)

    Grider, D.A.; Sturdivant, M.H.

    1991-01-01

    In nonnuclear business, administrative procedures bring to mind such mundane topics as filing correspondence and scheduling vacation time. In the nuclear industry, on the other hand, administrative procedures play a vital role in assuring the safe operation of a facility. For some time now, industry focus has been on improving technical procedures. Significant efforts are under way to produce technical procedure requires that a validated technical, regulatory, and administrative basis be developed and that the technical process be established for each procedure. Producing usable technical procedures requires that procedure presentation be engineered to the same human factors principles used in control room design. The vital safety role of administrative procedures requires that they be just as sound, just a rigorously formulated, and documented as technical procedures. Procedure programs at the Tennessee Valley Authority and at Boston Edison's Pilgrim Station demonstrate that human factors engineering techniques can be applied effectively to technical procedures. With a few modifications, those same techniques can be used to produce more effective administrative procedures. Efforts are under way at the US Department of Energy Nuclear Weapons Complex and at some utilities (Boston Edison, for instance) to apply human factors engineering to administrative procedures: The techniques being adapted include the following

  15. Procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Doyle, T.; Hare, W.S.C.; Thomson, K.; Tess, B.

    1989-01-01

    This book outlines the various procedures necessary for the successful practice of diagnostic radiology. Topics covered are: general principles, imaging of the urinary and gastrointestinal tracts, vascular radiology, arthrography, and miscellaneous diagnostic radiologic procedures

  16. Sensitivity analysis for large-scale problems

    Science.gov (United States)

    Noor, Ahmed K.; Whitworth, Sandra L.

    1987-01-01

    The development of efficient techniques for calculating sensitivity derivatives is studied. The objective is to present a computational procedure for calculating sensitivity derivatives as part of performing structural reanalysis for large-scale problems. The scope is limited to framed type structures. Both linear static analysis and free-vibration eigenvalue problems are considered.

  17. Procedural Media Representation

    OpenAIRE

    Henrysson, Anders

    2002-01-01

    We present a concept for using procedural techniques to represent media. Procedural methods allow us to represent digital media (2D images, 3D environments etc.) with very little information and to render it photo realistically. Since not all kind of content can be created procedurally, traditional media representations (bitmaps, polygons etc.) must be used as well. We have adopted an object-based media representation where an object can be represented either with a procedure or with its trad...

  18. A Computerized Procedure linked to Virtual Equipment

    International Nuclear Information System (INIS)

    Jung, Yeon Sub; Song, Tae Young

    2011-01-01

    Digital, information, and communication technologies have change human's behavior. This is because human has limitation to memorize and process information. Human has to access other information and real time information for important decisions. Those technologies are playing important roles. Nuclear power plants cannot be exception. Many accidents in nuclear power plants result from absent or incorrect information. The information for nuclear personnel is context sensitive. They don't have enough time to verify the context sensitive information. Therefore they skip the information, as resulting in incident. Nuclear personnel are usually carrying static paper procedures during local task performance. The procedure guides them steps to follow. There is, however, no dynamic and context sensitive information in the paper. The effect of the work is evaluated once while getting permission of the work. Afterward they are not informed. The static paper is generally simplified, so that it does not show detail of equipment being manipulated. Particularly novice workers feel difficult to understand the procedure due to lack of detail. Pictures of equipment inserted in the procedure are not enough for comprehension. A computerized procedure linked with virtual equipment is one of the best solutions to increase the detail of procedure. Virtual equipment, however, has still limitation not to provide real time information, because the virtual equipment is not synchronized with real plants

  19. Classification of radiological procedures

    International Nuclear Information System (INIS)

    1989-01-01

    A classification for departments in Danish hospitals which use radiological procedures. The classification codes consist of 4 digits, where the first 2 are the codes for the main groups. The first digit represents the procedure's topographical object and the second the techniques. The last 2 digits describe individual procedures. (CLS)

  20. Procedure generation and verification

    International Nuclear Information System (INIS)

    Sheely, W.F.

    1986-01-01

    The Department of Energy has used Artificial Intelligence of ''AI'' concepts to develop two powerful new computer-based techniques to enhance safety in nuclear applications. The Procedure Generation System, and the Procedure Verification System, can be adapted to other commercial applications, such as a manufacturing plant. The Procedure Generation System can create a procedure to deal with the off-normal condition. The operator can then take correct actions on the system in minimal time. The Verification System evaluates the logic of the Procedure Generator's conclusions. This evaluation uses logic techniques totally independent of the Procedure Generator. The rapid, accurate generation and verification of corrective procedures can greatly reduce the human error, possible in a complex (stressful/high stress) situation

  1. Generalized tolerance sensitivity and DEA metric sensitivity

    OpenAIRE

    Neralić, Luka; E. Wendell, Richard

    2015-01-01

    This paper considers the relationship between Tolerance sensitivity analysis in optimization and metric sensitivity analysis in Data Envelopment Analysis (DEA). Herein, we extend the results on the generalized Tolerance framework proposed by Wendell and Chen and show how this framework includes DEA metric sensitivity as a special case. Further, we note how recent results in Tolerance sensitivity suggest some possible extensions of the results in DEA metric sensitivity.

  2. Generalized tolerance sensitivity and DEA metric sensitivity

    Directory of Open Access Journals (Sweden)

    Luka Neralić

    2015-03-01

    Full Text Available This paper considers the relationship between Tolerance sensitivity analysis in optimization and metric sensitivity analysis in Data Envelopment Analysis (DEA. Herein, we extend the results on the generalized Tolerance framework proposed by Wendell and Chen and show how this framework includes DEA metric sensitivity as a special case. Further, we note how recent results in Tolerance sensitivity suggest some possible extensions of the results in DEA metric sensitivity.

  3. Civil Procedure In Denmark

    DEFF Research Database (Denmark)

    Werlauff, Erik

    scientific activities conducted by the author, partly based on the author's experience as a member, through a number of years, of the Danish Standing Committee on Procedural Law (Retsplejeraadet), which on a continuous basis evaluates the need for civil procedural reforms in Denmark, and finally also based......The book contains an up-to-date survey of Danish civil procedure after the profound Danish procedural reforms in 2007. It deals with questions concerning competence and function of Danish courts, commencement and preparation of civil cases, questions of evidence and burden of proof, international...... procedural questions, including relations to the Brussels I Regulation and Denmark's participation in this Regulation via a parallel convention with the EU countries, impact on Danish civil procedure of the convention on human rights, preparation and pronouncement of judgment and verdict, questions of appeal...

  4. Spline-procedures

    International Nuclear Information System (INIS)

    Schmidt, R.

    1976-12-01

    This report contains a short introduction to spline functions as well as a complete description of the spline procedures presently available in the HMI-library. These include polynomial splines (using either B-splines or one-sided basis representations) and natural splines, as well as their application to interpolation, quasiinterpolation, L 2 -, and Tchebycheff approximation. Special procedures are included for the case of cubic splines. Complete test examples with input and output are provided for each of the procedures. (orig.) [de

  5. Procedural sedation analgesia

    OpenAIRE

    Sheta, Saad A

    2010-01-01

    The number of noninvasive and minimally invasive procedures performed outside of the operating room has grown exponentially over the last several decades. Sedation, analgesia, or both may be needed for many of these interventional or diagnostic procedures. Individualized care is important when determining if a patient requires procedural sedation analgesia (PSA). The patient might need an anti-anxiety drug, pain medicine, immobilization, simple reassurance, or a combination of these interve...

  6. Measuring value sensitivity in medicine.

    Science.gov (United States)

    Ineichen, Christian; Christen, Markus; Tanner, Carmen

    2017-01-28

    Value sensitivity - the ability to recognize value-related issues when they arise in practice - is an indispensable competence for medical practitioners to enter decision-making processes related to ethical questions. However, the psychological competence of value sensitivity is seldom an explicit subject in the training of medical professionals. In this contribution, we outline the traditional concept of moral sensitivity in medicine and its revised form conceptualized as value sensitivity and we propose an instrument that measures value sensitivity. We developed an instrument for assessing the sensitivity for three value groups (moral-related values, values related to the principles of biomedical ethics, strategy-related values) in a four step procedure: 1) value identification (n = 317); 2) value representation (n = 317); 3) vignette construction and quality evaluation (n = 37); and 4) instrument validation by comparing nursing professionals with hospital managers (n = 48). We find that nursing professionals recognize and ascribe importance to principle-related issues more than professionals from hospital management. The latter are more likely to recognize and ascribe importance to strategy-related issues. These hypothesis-driven results demonstrate the discriminatory power of our newly developed instrument, which makes it useful not only for health care professionals in practice but for students and people working in the clinical context as well.

  7. Portal monitor evaluation and test procedure

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Rich, B.L.

    1983-10-01

    The purpose was to develop techniques and procedures to allow users to measure performance and sensitivity of portal monitors. Additionally, a methodology was developed to assist users in optimizing monitor performance. The two monitors tested utilized thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: a) background count rate and the statistical variability, b) detector efficiency at different distances, c) moving source sensitivity for various size sources and speeds, and d) false alarm rates at different background levels. A model was developed for the moving source measurements to compare the experimental data with measured results, and to test whether it is possible to adequately model the behavior of a portal monitor's response to a moving source. The model results were compared with the actual test results. A procedure for testing portal monitors is also given. 1 reference, 9 figures, 8 tables

  8. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  9. Decision-making Procedures

    DEFF Research Database (Denmark)

    Aldashev, Gani; Kirchsteiger, Georg; Sebald, Alexander Christopher

    2009-01-01

    define procedures as mechanisms that influence the probabilities of reaching different endnodes. We show that for such procedural games a sequential psychological equilibrium always exists. Applying this approach within a principal-agent context we show that the way less attractive jobs are allocated...

  10. Maintenance procedure upgrade programs

    International Nuclear Information System (INIS)

    Campbell, J.J.; Zimmerman, C.M.

    1988-01-01

    This paper describes a systematic approach to upgrading nuclear power plant maintenance procedures. The approach consists of four phases: diagnosis, program planning, program implementation, and program evaluation. Each phase is explained as a series of steps to ensure that all factors in a procedure upgrade program are considered

  11. Actor-Network Procedures

    NARCIS (Netherlands)

    Pavlovic, Dusko; Meadows, Catherine; Ramanujam, R.; Ramaswamy, Srini

    2012-01-01

    In this paper we propose actor-networks as a formal model of computation in heterogenous networks of computers, humans and their devices, where these new procedures run; and we introduce Procedure Derivation Logic (PDL) as a framework for reasoning about security in actor-networks, as an extension

  12. Analytical procedures. Pt. 1

    International Nuclear Information System (INIS)

    Weber, G.

    1985-01-01

    In analytical procedures (Boole procedures) there is certain to be a close relationship between the safety assessment and reliability assessment of technical facilities. The paper gives an overview of the organization of models, fault trees, the probabilistic evaluation of systems, evaluation with minimum steps or minimum paths regarding statistically dependent components and of systems liable to suffer different kinds of outages. (orig.) [de

  13. Play vs. Procedures

    DEFF Research Database (Denmark)

    Hammar, Emil

    Through the theories of play by Gadamer (2004) and Henricks (2006), I will show how the relationship between play and game can be understood as dialectic and disruptive, thus challenging understandings of how the procedures of games determine player activity and vice versa. As such, I posit some...... analytical consequences for understandings of digital games as procedurally fixed (Boghost, 2006; Flannagan, 2009; Bathwaite & Sharp, 2010). That is, if digital games are argued to be procedurally fixed and if play is an appropriative and dialectic activity, then it could be argued that the latter affects...... and alters the former, and vice versa. Consequently, if the appointed procedures of a game are no longer fixed and rigid in their conveyance of meaning, qua the appropriative and dissolving nature of play, then understandings of games as conveying a fixed meaning through their procedures are inadequate...

  14. HASL procedures manual

    International Nuclear Information System (INIS)

    1980-08-01

    Addition and corrections to the following sections of the HASL Procedures Manual are provided: Table of Contents; Bibliography; Fallout Collection Methods; Wet/Dry Fallout Collection; Fluoride in Soil and Sediment; Strontium-90; Natural Series; Alpha Emitters; and Gamma Emitters

  15. EML procedures manual

    International Nuclear Information System (INIS)

    Volchok, H.L.; de Planque, G.

    1982-01-01

    This manual contains the procedures that are used currently by the Environmental Measurements Laboratory of the US Department of Energy. In addition a number of analytical methods from other laboratories have been included. These were tested for reliability at the Battelle, Pacific Northwest Laboratory under contract with the Division of Biomedical and Environmental Research of the AEC. These methods are clearly distinguished. The manual is prepared in loose leaf form to facilitate revision of the procedures and inclusion of additional procedures or data sheets. Anyone receiving the manual through EML should receive this additional material automatically. The contents are as follows: (1) general; (2) sampling; (3) field measurements; (4) general analytical chemistry; (5) chemical procedures; (6) data section; (7) specifications

  16. Cosmetic Procedure Questions

    Science.gov (United States)

    ... for Every Season How to Choose the Best Skin Care Products In This Section Dermatologic Surgery What is dermatologic ... for Every Season How to Choose the Best Skin Care Products Cosmetic Procedure Questions Want to look younger? Start ...

  17. Modified arthroscopic Brostrom procedure.

    Science.gov (United States)

    Lui, Tun Hing

    2015-09-01

    The open modified Brostrom anatomic repair technique is widely accepted as the reference standard for lateral ankle stabilization. However, there is high incidence of intra-articular pathologies associated with chronic lateral ankle instability which may not be addressed by an isolated open Brostrom procedure. Arthroscopic Brostrom procedure with suture anchor has been described for anatomic repair of chronic lateral ankle instability and management of intra-articular lesions. However, the complication rates seemed to be higher than open Brostrom procedure. Modification of the arthroscopic Brostrom procedure with the use of bone tunnel may reduce the risk of certain complications. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  18. Assisted Medical Procedures (AMP)

    Data.gov (United States)

    National Aeronautics and Space Administration — DOCUMENTATION, DEVELOPMENT, AND PROGRESS The AMP was initially being developed as part the Advanced Integrated Clinical System (AICS)-Guided Medical Procedure System...

  19. Cosmetic Procedure Questions

    Science.gov (United States)

    ... Back Injectable Deoxycholic Acid Injectable Hyaluronic Acid Injectable Poly-l-lactic Acid Injectable Polymethylmethacrylate + Bovine Collagen Filler ... time of their procedure. 6. What are my pain management and anesthesia options? To help avoid the ...

  20. Special Blood Donation Procedures

    Science.gov (United States)

    ... Blood Products Special Blood Donation Procedures Precautions and Adverse Reactions During Blood Transfusion (See Overview of Blood Transfusion .) Plateletpheresis (platelet donation) In plateletpheresis, a donor gives only platelets rather than whole blood. Whole ...

  1. Dynamic alarm response procedures

    International Nuclear Information System (INIS)

    Martin, J.; Gordon, P.; Fitch, K.

    2006-01-01

    The Dynamic Alarm Response Procedure (DARP) system provides a robust, Web-based alternative to existing hard-copy alarm response procedures. This paperless system improves performance by eliminating time wasted looking up paper procedures by number, looking up plant process values and equipment and component status at graphical display or panels, and maintenance of the procedures. Because it is a Web-based system, it is platform independent. DARP's can be served from any Web server that supports CGI scripting, such as Apache R , IIS R , TclHTTPD, and others. DARP pages can be viewed in any Web browser that supports Javascript and Scalable Vector Graphics (SVG), such as Netscape R , Microsoft Internet Explorer R , Mozilla Firefox R , Opera R , and others. (authors)

  2. Radiochemical procedures and techniques

    International Nuclear Information System (INIS)

    Flynn, K.

    1975-04-01

    A summary is presented of the radiochemical procedures and techniques currently in use by the Chemistry Division Nuclear Chemistry Group at Argonne National Laboratory for the analysis of radioactive samples. (U.S.)

  3. Soil Sampling Operating Procedure

    Science.gov (United States)

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil samples for field screening or laboratory analysis.

  4. Bariatric Surgery Procedures

    Science.gov (United States)

    ... Meetings of Interest Online Education Job Board CME Policies CBN Fellowship Certificate Research Grant Program Resources All Resources Approved Procedures Patient Safety Vignettes Dr. Mason Historical Library Governing Documents Guidelines Access and Insurance Position and ...

  5. Nuclear materials management procedures

    International Nuclear Information System (INIS)

    Veevers, K.; Silver, J.M.; Quealy, K.J.; Steege, E. van der.

    1987-10-01

    This manual describes the procedures for the management of nuclear materials and associated materials at the Lucas Heights Research Laboratories. The procedures are designed to comply with Australia's nuclear non-proliferation obligations to the International Atomic Energy Agency (IAEA), bilateral agreements with other countries and ANSTO's responsibilities under the Nuclear Non-Proliferation (Safeguards) Act, 1987. The manual replaces those issued by the Australian Atomic Energy Commission in 1959, 1960 and 1969

  6. Sensitivity functions for uncertainty analysis: Sensitivity and uncertainty analysis of reactor performance parameters

    International Nuclear Information System (INIS)

    Greenspan, E.

    1982-01-01

    This chapter presents the mathematical basis for sensitivity functions, discusses their physical meaning and information they contain, and clarifies a number of issues concerning their application, including the definition of group sensitivities, the selection of sensitivity functions to be included in the analysis, and limitations of sensitivity theory. Examines the theoretical foundation; criticality reset sensitivities; group sensitivities and uncertainties; selection of sensitivities included in the analysis; and other uses and limitations of sensitivity functions. Gives the theoretical formulation of sensitivity functions pertaining to ''as-built'' designs for performance parameters of the form of ratios of linear flux functionals (such as reaction-rate ratios), linear adjoint functionals, bilinear functions (such as reactivity worth ratios), and for reactor reactivity. Offers a consistent procedure for reducing energy-dependent or fine-group sensitivities and uncertainties to broad group sensitivities and uncertainties. Provides illustrations of sensitivity functions as well as references to available compilations of such functions and of total sensitivities. Indicates limitations of sensitivity theory originating from the fact that this theory is based on a first-order perturbation theory

  7. Automating sensitivity analysis of computer models using computer calculus

    International Nuclear Information System (INIS)

    Oblow, E.M.; Pin, F.G.

    1986-01-01

    An automated procedure for performing sensitivity analysis has been developed. The procedure uses a new FORTRAN compiler with computer calculus capabilities to generate the derivatives needed to set up sensitivity equations. The new compiler is called GRESS - Gradient Enhanced Software System. Application of the automated procedure with direct and adjoint sensitivity theory for the analysis of non-linear, iterative systems of equations is discussed. Calculational efficiency consideration and techniques for adjoint sensitivity analysis are emphasized. The new approach is found to preserve the traditional advantages of adjoint theory while removing the tedious human effort previously needed to apply this theoretical methodology. Conclusions are drawn about the applicability of the automated procedure in numerical analysis and large-scale modelling sensitivity studies

  8. Automating sensitivity analysis of computer models using computer calculus

    International Nuclear Information System (INIS)

    Oblow, E.M.; Pin, F.G.

    1985-01-01

    An automated procedure for performing sensitivity analyses has been developed. The procedure uses a new FORTRAN compiler with computer calculus capabilities to generate the derivatives needed to set up sensitivity equations. The new compiler is called GRESS - Gradient Enhanced Software System. Application of the automated procedure with ''direct'' and ''adjoint'' sensitivity theory for the analysis of non-linear, iterative systems of equations is discussed. Calculational efficiency consideration and techniques for adjoint sensitivity analysis are emphasized. The new approach is found to preserve the traditional advantages of adjoint theory while removing the tedious human effort previously needed to apply this theoretical methodology. Conclusions are drawn about the applicability of the automated procedure in numerical analysis and large-scale modelling sensitivity studies. 24 refs., 2 figs

  9. An unstructured finite volume solver for two phase water/vapour flows based on an elliptic oriented fractional step method

    International Nuclear Information System (INIS)

    Mechitoua, N.; Boucker, M.; Lavieville, J.; Pigny, S.; Serre, G.

    2003-01-01

    Based on experience gained at EDF and Cea, a more general and robust 3-dimensional (3D) multiphase flow solver has been being currently developed for over three years. This solver, based on an elliptic oriented fractional step approach, is able to simulate multicomponent/multiphase flows. Discretization follows a 3D full unstructured finite volume approach, with a collocated arrangement of all variables. The non linear behaviour between pressure and volume fractions and a symmetric treatment of all fields are taken into account in the iterative procedure, within the time step. It greatly enforces the realizability of volume fractions (i.e 0 < α < 1), without artificial numerical needs. Applications to widespread test cases as static sedimentation, water hammer and phase separation are shown to assess the accuracy and the robustness of the flow solver in different flow conditions, encountered in nuclear reactors pipes. (authors)

  10. Procedural learning and dyslexia.

    Science.gov (United States)

    Nicolson, R I; Fawcett, A J; Brookes, R L; Needle, J

    2010-08-01

    Three major 'neural systems', specialized for different types of information processing, are the sensory, declarative, and procedural systems. It has been proposed (Trends Neurosci., 30(4), 135-141) that dyslexia may be attributable to impaired function in the procedural system together with intact declarative function. We provide a brief overview of the increasing evidence relating to the hypothesis, noting that the framework involves two main claims: first that 'neural systems' provides a productive level of description avoiding the underspecificity of cognitive descriptions and the overspecificity of brain structural accounts; and second that a distinctive feature of procedural learning is its extended time course, covering from minutes to months. In this article, we focus on the second claim. Three studies-speeded single word reading, long-term response learning, and overnight skill consolidation-are reviewed which together provide clear evidence of difficulties in procedural learning for individuals with dyslexia, even when the tasks are outside the literacy domain. The educational implications of the results are then discussed, and in particular the potential difficulties that impaired overnight procedural consolidation would entail. It is proposed that response to intervention could be better predicted if diagnostic tests on the different forms of learning were first undertaken. 2010 John Wiley & Sons, Ltd.

  11. Procedural sedation analgesia

    Directory of Open Access Journals (Sweden)

    Sheta Saad

    2010-01-01

    Full Text Available The number of noninvasive and minimally invasive procedures performed outside of the operating room has grown exponentially over the last several decades. Sedation, analgesia, or both may be needed for many of these interventional or diagnostic procedures. Individualized care is important when determining if a patient requires procedural sedation analgesia (PSA. The patient might need an anti-anxiety drug, pain medicine, immobilization, simple reassurance, or a combination of these interventions. The goals of PSA in four different multidisciplinary practices namely; emergency, dentistry, radiology and gastrointestinal endoscopy are discussed in this review article. Some procedures are painful, others painless. Therefore, goals of PSA vary widely. Sedation management can range from minimal sedation, to the extent of minimal anesthesia. Procedural sedation in emergency department (ED usually requires combinations of multiple agents to reach desired effects of analgesia plus anxiolysis. However, in dental practice, moderate sedation analgesia (known to the dentists as conscious sedation is usually what is required. It is usually most effective with the combined use of local anesthesia. The mainstay of success for painless imaging is absolute immobility. Immobility can be achieved by deep sedation or minimal anesthesia. On the other hand, moderate sedation, deep sedation, minimal anesthesia and conventional general anesthesia can be all utilized for management of gastrointestinal endoscopy.

  12. New optical sensing technique of tissue viability and blood flow based on nanophotonic iterative multi-plane reflectance measurements

    Directory of Open Access Journals (Sweden)

    Yariv I

    2016-10-01

    Full Text Available Inbar Yariv,1 Menashe Haddad,2,3 Hamootal Duadi,1 Menachem Motiei,1 Dror Fixler1 1Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel; 2Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel; 3Mayanei Hayeshua Medical Center, Benei Brak, Israel Abstract: Physiological substances pose a challenge for researchers since their optical properties change constantly according to their physiological state. Examination of those substances noninvasively can be achieved by different optical methods with high sensitivity. Our research suggests the application of a novel noninvasive nanophotonics technique, ie, iterative multi-plane optical property extraction (IMOPE based on reflectance measurements, for tissue viability examination and gold nanorods (GNRs and blood flow detection. The IMOPE model combines an experimental setup designed for recording light intensity images with the multi-plane iterative Gerchberg-Saxton algorithm for reconstructing the reemitted light phase and calculating its standard deviation (STD. Changes in tissue composition affect its optical properties which results in changes in the light phase that can be measured by its STD. We have demonstrated this new concept of correlating the light phase STD and the optical properties of a substance, using transmission measurements only. This paper presents, for the first time, reflectance based IMOPE tissue viability examination, producing a decrease in the computed STD for older tissues, as well as investigating their organic material absorption capability. Finally, differentiation of the femoral vein from adjacent tissues using GNRs and the detection of their presence within blood circulation and tissues are also presented with high sensitivity (better than computed tomography to low quantities of GNRs (<3 mg. Keywords: Gerchberg-Saxton, optical properties, gold nanorods, blood vessel, tissue viability

  13. Experimental demonstration of an OpenFlow based software-defined optical network employing packet, fixed and flexible DWDM grid technologies on an international multi-domain testbed.

    Science.gov (United States)

    Channegowda, M; Nejabati, R; Rashidi Fard, M; Peng, S; Amaya, N; Zervas, G; Simeonidou, D; Vilalta, R; Casellas, R; Martínez, R; Muñoz, R; Liu, L; Tsuritani, T; Morita, I; Autenrieth, A; Elbers, J P; Kostecki, P; Kaczmarek, P

    2013-03-11

    Software defined networking (SDN) and flexible grid optical transport technology are two key technologies that allow network operators to customize their infrastructure based on application requirements and therefore minimizing the extra capital and operational costs required for hosting new applications. In this paper, for the first time we report on design, implementation & demonstration of a novel OpenFlow based SDN unified control plane allowing seamless operation across heterogeneous state-of-the-art optical and packet transport domains. We verify and experimentally evaluate OpenFlow protocol extensions for flexible DWDM grid transport technology along with its integration with fixed DWDM grid and layer-2 packet switching.

  14. Anesthesia for radiologic procedures

    International Nuclear Information System (INIS)

    Forestner, J.E.

    1987-01-01

    Anesthetic techniques for neurodiagnostic studies and radiation therapy have been recently reviewed, but anesthetic involvement in thoracic and abdominal radiology has received little attention. Patient reactions to radiologic contrast media may be of concern to the anesthesiologist, who is often responsible for injecting these agents during diagnostic procedures, and thus is included in this discussion. Finally, the difficulties of administering anesthesia for magnetic resonance imaging (MRI) scans are outlined, in an effort to help anesthesiologist to anticipate problems with this new technologic development. Although there are very few indications for the use of general anesthesia for diagnostic radiologic studies in adults, most procedures performed with children, the mentally retarded, or the combative adult require either heavy sedation or general anesthesia. In selecting an anesthetic technique for a specific procedure, both the patient's disease process and the requirements of the radiologist must be carefully balanced

  15. Motive Criminal Procedure Evidence

    Directory of Open Access Journals (Sweden)

    В. В. Вапнярчук

    2015-03-01

    Full Text Available In the article the need for such a level of mental regulation of behavior of proving motivation. The latter refers to internal motivation conscious entity Criminal Procedure proof, due to specific needs, interests and goals that cause a person to act rishymist. Detailed attention is given to the first two determinants, namely the nature of needs and interests. In particular, analyzes highlighted in the literature variety of needs (physiological, ekzistentsionalni, social, prestige, cognitive, aesthetic and spiritual and the manifestation of some of them in the criminal procedural proof.

  16. 76 FR 62092 - Filing Procedures

    Science.gov (United States)

    2011-10-06

    ... INTERNATIONAL TRADE COMMISSION Filing Procedures AGENCY: International Trade Commission. ACTION: Notice of issuance of Handbook on Filing Procedures. SUMMARY: The United States International Trade Commission (``Commission'') is issuing a Handbook on Filing Procedures to replace its Handbook on Electronic...

  17. Electronic procedure distribution

    International Nuclear Information System (INIS)

    Slone, B.J. III; Richardson, C.E.

    1993-01-01

    Printed procedures can offer a mix of text and graphic information that improves readability and increases understanding. A typical procedure uses illustrations and graphics to clarify concepts, a variety of type styles and weights to make it easier to find different topics and sections, white space to improve readability, and familiar navigational clues such as page numbers and topic headers. Initially, electronic procedure systems had limited typeface options, often only a single typeface, with no capability for enhancing readability by varying type size bolding, italicizing, or underlining, and no ability to include graphics. Even recently, many text-only electronic procedures were originally created in a modern What-You-See-Is-What-You-Get (WYSI-WYG) document authoring system, only to be converted to pages and pages of plain type for electronic distribution. Given the choice of paper or on-line producers, most users have chosen paper for its readability. But current-generation electronic document systems that use formatted text and embedded graphics offer users vastly improved readability. Further, they are offering ever-better search tools to enable rapid location of material of interest

  18. The nuclear licensing procedure

    International Nuclear Information System (INIS)

    Wagner, H.

    1976-01-01

    To begin with, the present nuclear licensing procedure is illustrated by a diagram. The relationship between the state and the Laender, the various experts (GRS - IRS + LRA -, TUEV, DWD, university institutes, firms of consulting engineers, etc), participation of the public, e.g. publication of the relevant documents, questions, objections (made by individuals or by groups such as citizens' initiatives), public discussion, official notice, appeals against the decision, the right of immediate execution of the decision are shortly dealt with. Finally, ways to improve the licensing procedure are discussed, from the evaluation of the documents to be submitted, published, and examined by the authorities (and their experts) up to an improvement of the administrative procedure. An improved licensing procedure should satisfy the well-founded claims of the public for more transparency as well as the equally justifiable claims of industry and utilities in order to ensure that the citizens' legal right to have safe and adequate electric power is guaranteed. The updated energy programme established by the Federal Government is mentioned along with the effectiveness of dealing with nuclear problems on the various levels of a Land government. (orig.) [de

  19. OCRWM international procedures

    International Nuclear Information System (INIS)

    1986-03-01

    These international procedures provide guidance and assistance for the Office of Civilian Radioactive Waste Management (OCRWM) and for OCRWM Project Offices, contractors and subcontractors in conducting international activities. They supplement the relevant Department of Energy (DOE) orders (which are referenced), not supplant them

  20. Pneumomediastinum after odontologic procedure

    International Nuclear Information System (INIS)

    Olivella C, Fabio Alejandro; Bermudez G, Mary; Hidalgo M, Patricia; Sanchez M, Jully Mariana; Solarte R, Ivan; Uriza C, Felipe

    2005-01-01

    The sudden increase in alveolar pressure is a frequent cause of pneumomediastinum, but there are other reasons that could lead to it such as airway or esophagus trauma. The pneumomediastinum, which has been produced after dental procedures, is very rare and product deserves special attention by dentists and medical personnel in order to get its soon recognition and handling

  1. Educational Accounting Procedures.

    Science.gov (United States)

    Tidwell, Sam B.

    This chapter of "Principles of School Business Management" reviews the functions, procedures, and reports with which school business officials must be familiar in order to interpret and make decisions regarding the school district's financial position. Among the accounting functions discussed are financial management, internal auditing,…

  2. Robust procedures in chemometrics

    DEFF Research Database (Denmark)

    Kotwa, Ewelina

    properties of the analysed data. The broad theoretical background of robust procedures was given as a very useful supplement to the classical methods, and a new tool, based on robust PCA, aiming at identifying Rayleigh and Raman scatters in excitation-mission (EEM) data was developed. The results show...

  3. IXM gas sampling procedure

    International Nuclear Information System (INIS)

    Pingel, L.A.

    1995-01-01

    Ion Exchange Modules (IXMs) are used at the 105-KE and -KW Fuel Storage Basins to control radionuclide concentrations in the water. A potential safety concern relates to production of hydrogen gas by radiolysis of the water trapped in the ion exchange media of spent IXMs. This document provides a procedure for sampling the gases in the head space of the IXM

  4. 3. Procedures and Recursion

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 1; Issue 6. Algorithms Procedures and Recursion. R K Shyamasundar. Series Article Volume 1 ... Author Affiliations. R K Shyamasundar1. Computer Science Group, Tata Institute of Fundamental Research, Homi Bhabha Road Mumbai 400 005, India.

  5. The TOMAX-procedure

    NARCIS (Netherlands)

    Overgoor, M.L.E.

    2015-01-01

    Most patients with a low spinal lesion (LSL) have intact erectile function but no penile sensation, which can lead to frustration. To tackle this problem, we designed TOMAX, TOMAXimize sensation, sexuality and quality of life, a surgical procedure in which a functional "groin” nerve is connected to

  6. Experiments with Cloze Procedure

    Science.gov (United States)

    Evans, Gordon; Haastrup, Kirsten

    1976-01-01

    The Nordic Test Development Group prepared proficiency tests of English designed to provide reliable information on which to base decisions as to whether a candidate would be able to function in a job as described or whether he could be trained to do so. Two subtests used a modified cloze procedure. (Author/CFM)

  7. Formalizing physical security procedures

    NARCIS (Netherlands)

    Meadows, C.; Pavlovic, Dusko

    Although the problems of physical security emerged more than 10,000 years before the problems of computer security, no formal methods have been developed for them, and the solutions have been evolving slowly, mostly through social procedures. But as the traffic on physical and social networks is now

  8. DEVELOPMENT OF SENSITIVITY TO ESTHETIC VALUES.

    Science.gov (United States)

    CHILD, IRVIN L.

    THE OBJECTS OF THIS STUDY WERE (1) TO DETERMINE THE DEVELOPMENT OF AVERAGE ESTHETIC SENSITIVITY TO VISUAL ART THROUGH THE ELEMENTARY AND SECONDARY SCHOOL YEARS AND (2) TO DETERMINE IF APPROPRIATE TRAINING PROCEDURES WOULD LEAD CHILDREN TO DISCRIMINATE BETWEEN WORKS CONSIDERED BETTER OR POORER BY EXPERTS. CHILDREN FROM GRADES 1 TO 12 WERE PRESENTED…

  9. Entropy feature extraction on flow pattern of gas/liquid two-phase flow based on cross-section measurement

    International Nuclear Information System (INIS)

    Han, J; Dong, F; Xu, Y Y

    2009-01-01

    This paper introduces the fundamental of cross-section measurement system based on Electrical Resistance Tomography (ERT). The measured data of four flow regimes of the gas/liquid two-phase flow in horizontal pipe flow are obtained by an ERT system. For the measured data, five entropies are extracted to analyze the experimental data according to the different flow regimes, and the analysis method is examined and compared in three different perspectives. The results indicate that three different perspectives of entropy-based feature extraction are sensitive to the flow pattern transition in gas/liquid two-phase flow. By analyzing the results of three different perspectives with the changes of gas/liquid two-phase flow parameters, the dynamic structures of gas/liquid two-phase flow is obtained, and they also provide an efficient supplementary to reveal the flow pattern transition mechanism of gas/liquid two-phase flow. Comparison of the three different methods of feature extraction shows that the appropriate entropy should be used for the identification and prediction of flow regimes.

  10. Probabilistic Cash Flow-Based Optimal Investment Timing Using Two-Color Rainbow Options Valuation for Economic Sustainability Appraisement

    Directory of Open Access Journals (Sweden)

    Yonggu Kim

    2017-10-01

    Full Text Available This research determines the optimal investment timing using real options valuation to support decision-making for economic sustainability assessment. This paper illustrates an option pricing model using the Black-Scholes model applied to a case project to understand the model performance. Applicability of the project to the model requires two Monte Carlo simulations to satisfy a Markov process and a Wiener process. The position of project developers is not only the seller of products, but it is also the buyer of raw materials. Real options valuation can be influenced by the volatility of cash outflow, as well as the volatility of cash inflow. This study suggests two-color rainbow options valuation to overcome this issue, which is demonstrated for a steel plant project. The asymmetric results of the case study show that cash outflow (put option influences the value of the steel plant project more than cash inflow (call option does of which the discussion of the results is referred to a sensitivity analysis. The real options valuation method proposed in this study contributes to the literature on applying the new model, taking into consideration that investors maximize project profitability for economic sustainable development.

  11. Integrated light-sheet imaging and flow-based enquiry (iLIFE) system for 3D in-vivo imaging of multicellular organism

    Science.gov (United States)

    Rasmi, Chelur K.; Padmanabhan, Sreedevi; Shirlekar, Kalyanee; Rajan, Kanhirodan; Manjithaya, Ravi; Singh, Varsha; Mondal, Partha Pratim

    2017-12-01

    We propose and demonstrate a light-sheet-based 3D interrogation system on a microfluidic platform for screening biological specimens during flow. To achieve this, a diffraction-limited light-sheet (with a large field-of-view) is employed to optically section the specimens flowing through the microfluidic channel. This necessitates optimization of the parameters for the illumination sub-system (illumination intensity, light-sheet width, and thickness), microfluidic specimen platform (channel-width and flow-rate), and detection sub-system (camera exposure time and frame rate). Once optimized, these parameters facilitate cross-sectional imaging and 3D reconstruction of biological specimens. The proposed integrated light-sheet imaging and flow-based enquiry (iLIFE) imaging technique enables single-shot sectional imaging of a range of specimens of varying dimensions, ranging from a single cell (HeLa cell) to a multicellular organism (C. elegans). 3D reconstruction of the entire C. elegans is achieved in real-time and with an exposure time of few hundred micro-seconds. A maximum likelihood technique is developed and optimized for the iLIFE imaging system. We observed an intracellular resolution for mitochondria-labeled HeLa cells, which demonstrates the dynamic resolution of the iLIFE system. The proposed technique is a step towards achieving flow-based 3D imaging. We expect potential applications in diverse fields such as structural biology and biophysics.

  12. Chemical kinetic functional sensitivity analysis: Elementary sensitivities

    International Nuclear Information System (INIS)

    Demiralp, M.; Rabitz, H.

    1981-01-01

    Sensitivity analysis is considered for kinetics problems defined in the space--time domain. This extends an earlier temporal Green's function method to handle calculations of elementary functional sensitivities deltau/sub i//deltaα/sub j/ where u/sub i/ is the ith species concentration and α/sub j/ is the jth system parameter. The system parameters include rate constants, diffusion coefficients, initial conditions, boundary conditions, or any other well-defined variables in the kinetic equations. These parameters are generally considered to be functions of position and/or time. Derivation of the governing equations for the sensitivities and the Green's funciton are presented. The physical interpretation of the Green's function and sensitivities is given along with a discussion of the relation of this work to earlier research

  13. Cancer pancreatis, diagnostic procedures

    International Nuclear Information System (INIS)

    Graadal, Oe.; Schlichting, E.; Aasen, A.O.; Stadaas, J.O.

    1990-01-01

    151 patients treated for carcinoma of the pancreas at Ullevaal Hospital (Oslo University) during the period 1980-89 were studied. The most common initial symptom was abdominal pain. Other frequent debut symptoms were loss of weight and jaundice. ERCP and PTC were found to be the best diagnostic procedures. CT or ultrasonography were normal in 10-20% of the patients. Nearly all tumors of the pancreas were found by the ERCP procedure. Also angiography was used to evaluate operability of the pancreas tumor, but was found to be a very uncertain diagnostic method. This method will not be used in the future evaluation of patients with cancer of the pancreas. 13 refs., 1 fig., 2 tabs

  14. Subsea HIPPS design procedure

    International Nuclear Information System (INIS)

    Aaroe, R.; Lund, B.F.; Onshus, T.

    1995-01-01

    The paper is based on a feasibility study investigating the possibilities of using a HIPPS (High Integrity Pressure Protection System) to protect a subsea pipeline that is not rated for full wellhead shut-in pressure. The study was called the Subsea OPPS Feasibility Study, and was performed by SINTEF, Norway. Here, OPPS is an acronym for Overpressure Pipeline Protection System. A design procedure for a subsea HIPPS is described, based on the experience and knowledge gained through the ''Subsea OPPS Feasibility Study''. Before a subsea HIPPS can be applied, its technical feasibility, reliability and profitability must be demonstrated. The subsea HIPPS design procedure will help to organize and plan the design activities both with respect to development and verification of a subsea HIPPS. The paper also gives examples of how some of the discussed design steps were performed in the Subsea OPPS Feasibility Study. Finally, further work required to apply a subsea HIPPS is discussed

  15. Multiple predictor smoothing methods for sensitivity analysis: Description of techniques

    International Nuclear Information System (INIS)

    Storlie, Curtis B.; Helton, Jon C.

    2008-01-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described: (i) locally weighted regression (LOESS), (ii) additive models, (iii) projection pursuit regression, and (iv) recursive partitioning regression. Then, in the second and concluding part of this presentation, the indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present

  16. Multiple predictor smoothing methods for sensitivity analysis: Example results

    International Nuclear Information System (INIS)

    Storlie, Curtis B.; Helton, Jon C.

    2008-01-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described in the first part of this presentation: (i) locally weighted regression (LOESS), (ii) additive models, (iii) projection pursuit regression, and (iv) recursive partitioning regression. In this, the second and concluding part of the presentation, the indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present

  17. Headache and endovascular procedures.

    Science.gov (United States)

    de Biase, Stefano; Longoni, Marco; Gigli, Gian Luigi; Agostoni, Elio

    2017-05-01

    The International Classification of Headache Disorders (ICHD-3 beta) includes headache attributed to intracranial endovascular procedures (EVPs). The aim of this review is to describe the clinical and pathophysiological aspects of headache related to vascular lesions and EVPs. Current studies regarding this issue are contradictory, although generally favouring headache improvement after EVPs. Further large studies are needed to adequately assess the effect of EVPs on headache.

  18. Internal Control Organization Procedure

    OpenAIRE

    Radu Dorin Lenghel

    2013-01-01

    Internal control represents the totality of policies and procedures adopted by management, which contribute: to the fulfilment of managerial objectives, to the prevention and detection of frauds or errors, to the accuracy and exhaustiveness of accounting entries, as well as to the preparation in due course of financial accounting information. Internal control represents a managerial instrument which assures the fulfilment of objectives of the entity, being an ongoing process in which administ...

  19. Analytical Procedures for Testability.

    Science.gov (United States)

    1983-01-01

    Beat Internal Classifications", AD: A018516. "A System of Computer Aided Diagnosis with Blood Serum Chemistry Tests and Bayesian Statistics", AD: 786284...6 LIST OF TALS .. 1. Truth Table ......................................... 49 2. Covering Problem .............................. 93 3. Primary and...quential classification procedure in a coronary care ward is evaluated. In the toxicology field "A System of Computer Aided Diagnosis with Blood Serum

  20. The TOMAX-procedure

    OpenAIRE

    Overgoor, M.L.E.

    2015-01-01

    Most patients with a low spinal lesion (LSL) have intact erectile function but no penile sensation, which can lead to frustration. To tackle this problem, we designed TOMAX, TOMAXimize sensation, sexuality and quality of life, a surgical procedure in which a functional "groin” nerve is connected to the non-functional “penile” nerve on one side to bypass the LSL. Our goal was to increase LSL patients’ sexual health by restoring penile sensation: we show that TOMAX can achieve dramatic improvem...

  1. Start-up procedure

    International Nuclear Information System (INIS)

    Marchl, A.; Krebs, W.D.; Aleite, W.

    1975-01-01

    The start-up procedure will be shown on a pressurized water reactor, although most of the activities will occur similarly in other reactor types. The commissioning time can be divided into 5 sections, the phases A to E together lasting 26 months. Subsequently there are a test run of one month and the handling-over of the plant to the operator. A survey of the commissioning sections with several important main events is shown. (orig./TK) [de

  2. Numerical model for swirl flow cooling in high-heat-flux particle beam targets and the design of a swirl-flow-based plasma limiter

    International Nuclear Information System (INIS)

    Milora, S.L.; Combs, S.K.; Foster, C.A.

    1984-11-01

    An unsteady, two-dimensional heat conduction code has been used to study the performance of swirl-flow-based neutral particle beam targets. The model includes the effects of two-phase heat transfer and asymmetric heating of tubular elements. The calorimeter installed in the Medium Energy Test Facility, which has been subjected to 30-s neutral beam pulses with incident heat flux intensities of greater than or equal to 5 kW/cm 2 , has been modeled. The numerical results indicate that local heat fluxes in excess of 7 kW/cm 2 occur at the water-cooled surface on the side exposed to the beam. This exceeds critical heat flux limits for uniformly heated tubes wih straight flow by approximately a factor of 5. The design of a plasma limiter based on swirl flow heat transfer is presented

  3. Coal pillar design procedures

    CSIR Research Space (South Africa)

    York, G

    2000-03-01

    Full Text Available Final Project Report Coal pillar design procedures G. York, I. Canbulat, B.W. Jack Research agency: CSIR Mining Technology Project number: COL 337 Date: March 2000 2 Executive Summary Examination of collapsed pillar cases outside of the empirical... in strength occurs with increasing specimen size. 45 40 35 30 25 20 15 10 5 0 20 40 60 80 100 120 140 160 UNIAX IA L COMPR EHEN SIV E S TR ENG TH (M Pa ) CUBE SIZE (cm) Figure 1...

  4. Emergency procedures in London

    International Nuclear Information System (INIS)

    Cree, D.

    1984-01-01

    This chapter discusses the following: emergency services (fire brigade, ambulance and police) that would be involved in dealing with an accident to a nuclear fuel flask in transport through London, with special reference to procedures used by the Metropolitan Police; geographical area covered by Metropolitan Police; initiation of action; decision whether to evacuate the area of the accident; examples of action taken to deal with non-radiation accidents (in absence of any example of relevant radiation accident); specific instructions, or advice, to police relating to the movement of irradiated fuel; training exercises. (U.K.)

  5. Cognition and procedure representational requirements for predictive human performance models

    Science.gov (United States)

    Corker, K.

    1992-01-01

    including procedural backtracking with concurrent search, temporal reasoning, and constraint checking for partial ordering of procedures. Finally, the representation is being linked to models of human decision making processes that include heuristic, propositional and prescriptive judgement models that are sensitive to the procedural content in which the valuative functions are being performed.

  6. Context Sensitive Modeling of Cancer Drug Sensitivity.

    Directory of Open Access Journals (Sweden)

    Bo-Juen Chen

    Full Text Available Recent screening of drug sensitivity in large panels of cancer cell lines provides a valuable resource towards developing algorithms that predict drug response. Since more samples provide increased statistical power, most approaches to prediction of drug sensitivity pool multiple cancer types together without distinction. However, pan-cancer results can be misleading due to the confounding effects of tissues or cancer subtypes. On the other hand, independent analysis for each cancer-type is hampered by small sample size. To balance this trade-off, we present CHER (Contextual Heterogeneity Enabled Regression, an algorithm that builds predictive models for drug sensitivity by selecting predictive genomic features and deciding which ones should-and should not-be shared across different cancers, tissues and drugs. CHER provides significantly more accurate models of drug sensitivity than comparable elastic-net-based models. Moreover, CHER provides better insight into the underlying biological processes by finding a sparse set of shared and type-specific genomic features.

  7. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-07-25

    The purpose of the Regulations and Procedures Manual (RPM) is to provide LBNL personnel with a reference to University and Lawrence Berkeley National Laboratory (LBNL or Laboratory) policies and regulations by outlining normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory organizations. Much of the information in this manual has been condensed from detail provided in LBNL procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. RPM sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the LBNL organization responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which organization is responsible for a policy, please contact Requirements Manager Lydia Young or the RPM Editor.

  8. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2010-09-30

    The purpose of the Regulations and Procedures Manual (RPM) is to provide Laboratory personnel with a reference to University and Lawrence Berkeley National Laboratory policies and regulations by outlining the normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory departments. Much of the information in this manual has been condensed from detail provided in Laboratory procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. The sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the department responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which department should be called, please contact the Associate Laboratory Director of Operations.

  9. Sensitivity to friction for primary explosives.

    Science.gov (United States)

    Matyáš, Robert; Šelešovský, Jakub; Musil, Tomáš

    2012-04-30

    The sensitivity to friction for a selection of primary explosives has been studied using a small BAM friction apparatus. The probit analysis was used for the construction of a sensitivity curve for each primary explosive tested. Two groups of primary explosives were chosen for measurement (a) the most commonly used industrially produced primary explosives (e.g. lead azide, tetrazene, dinol, lead styphnate) and (b) the most produced improvised primary explosives (e.g. triacetone triperoxide, hexamethylenetriperoxide diamine, mercury fulminate, acetylides of heavy metals). A knowledge of friction sensitivity is very important for determining manipulation safety for primary explosives. All the primary explosives tested were carefully characterised (synthesis procedure, shape and size of crystals). The sensitivity curves obtained represent a unique set of data, which cannot be found anywhere else in the available literature. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. The sensitivity of a syndromic management approach in detecting ...

    African Journals Online (AJOL)

    In this setting, the Western Cape syndromic diagnostic procedure achieved reasonable levels of sensitivity in detecting Neisseria gonorrhoeae and Chlamydia trachornatis ID men and women, and in detecting Trichomonas vaginalis and bacterial vaginosis ID women. However, it was estimated to be only 36.4% sensitive in ...

  11. Structure sensitivity in adsorption

    DEFF Research Database (Denmark)

    Hammer, Bjørk; Nielsen, Ole Holm; Nørskov, Jens Kehlet

    1997-01-01

    The structure sensitivity of CO adsorption on different flat, stepped, kinked and reconstructed Pt surfaces is studied using large-scale density-functional calculations. We find an extremely strong structure sensitivity in the adsorption energy with variations up to 1 eV (or 100%) from one...... structure to the next. We propose a model to explain this behavior, and use it to discuss more generally the origin of structure sensitivity in heterogeneous catalysis....

  12. How sensitizing is chlorocresol?

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Hamann, K

    1984-01-01

    Chlorocresol is a biocide with widespread use in industry and pharmaceutical products. It is an occasional human contact sensitizer. The sensitizing potential of chlorocresol was judged strong using the guinea pig maximization test (GPMT) and doubtful in the less sensitive open epicutaneous test......% in pet. showed 11 reactions among 1462 patients tested, but none were explainable and reproducible during re-tests and provocative use tests, indicating that the GPMT overestimated the sensitization potential. The results from guinea pig allergy tests cannot stand alone but have to be validated by other...

  13. Radiation dose electrophysiology procedures

    International Nuclear Information System (INIS)

    Hernandez-Armas, J.; Rodriguez, A.; Catalan, A.; Hernandez Armas, O.; Luque Japon, L.; Moral, S.; Barroso, L.; Rfuez-Hdez, R.

    2006-01-01

    The aim of this paper has been to measure and analyse some of the parameters which are directly related with the doses given to patients in two electrophysiology procedures: diagnosis and ablation with radiofrequency. 16 patients were considered in this study. 13 them had an ablation with radiofrequency at the Unit of Electrophysiology at the University Hospital of the Canaries, La Laguna., Tenerife. The results of skin doses, in the ablation cases, were higher than 2 Gy (threshold of some deterministic effects). The average value was 1.1 Gy. The personal doses, measured under the lead apron, for physician and nurses were 4 and 3 micro Sievert. These results emphasised the necessity of radiation protection measures in order to reduce, ad much as possible, the doses to patients. (Author)

  14. Decommissioning licensing procedure

    International Nuclear Information System (INIS)

    Perello, M.

    1979-01-01

    Decommissioning or closure of a nuclear power plant, defined as the fact that takes place from the moment that the plant stops producing for the purpose it was built, is causing preocupation. So this specialist meeting on Regulatory Review seems to be the right place for presenting and discusing the need of considering the decommissioning in the safety analysis report. The main goal of this paper related to the licensing procedure is to suggest the need of a new chapter in the Preliminary Safety Analysis Report (P.S.A.R.) dealing with the decommissioning of the nuclear power plant. Therefore, after a brief introduction the problem is exposed from the point of view of nuclear safety and finally a format of the new chapter is proposed. (author)

  15. Procedure for the analysis of americium in complex matrices

    International Nuclear Information System (INIS)

    Knab, D.

    1978-02-01

    A radioanalytical procedure for the analysis of americium in complex matrices has been developed. Clean separations of americium can be obtained from up to 100 g of sample ash, regardless of the starting material. The ability to analyze large masses of material provides the increased sensitivity necessary to detect americium in many environmental samples. The procedure adequately decontaminates from rare earth elements and natural radioactive nuclides that interfere with the alpha spectrometric measurements

  16. Toddler test or procedure preparation

    Science.gov (United States)

    ... a test or procedure: Explain the procedure in language your child understands, using plain words. Avoid abstract terms. Make sure your child understands the exact body part involved in the test, and that the ...

  17. Preschooler test or procedure preparation

    Science.gov (United States)

    ... your child during and after the procedure with books, songs, counting, deep breathing, or blowing bubbles. PLAY ... can be present during the procedure. Ask if anesthesia can be used to reduce your child's discomfort. ...

  18. Automation of the testing procedure

    International Nuclear Information System (INIS)

    Haas, H.; Fleischer, M.; Bachner, E.

    1979-01-01

    For the judgement of technologies applied and the testing of specific components of the HTR primary circuit, complex test procedures and data evaluations are required. Extensive automation of these test procedures is indispensable. (orig.) [de

  19. Probabilistic sensitivity analysis in health economics.

    Science.gov (United States)

    Baio, Gianluca; Dawid, A Philip

    2015-12-01

    Health economic evaluations have recently become an important part of the clinical and medical research process and have built upon more advanced statistical decision-theoretic foundations. In some contexts, it is officially required that uncertainty about both parameters and observable variables be properly taken into account, increasingly often by means of Bayesian methods. Among these, probabilistic sensitivity analysis has assumed a predominant role. The objective of this article is to review the problem of health economic assessment from the standpoint of Bayesian statistical decision theory with particular attention to the philosophy underlying the procedures for sensitivity analysis. © The Author(s) 2011.

  20. Quantization Procedures; Sistemas de cuantificacion

    Energy Technology Data Exchange (ETDEWEB)

    Cabrera, J. A.; Martin, R.

    1976-07-01

    We present in this work a review of the conventional quantization procedure, the proposed by I.E. Segal and a new quantization procedure similar to this one for use in non linear problems. We apply this quantization procedures to different potentials and we obtain the appropriate equations of motion. It is shown that for the linear case the three procedures exposed are equivalent but for the non linear cases we obtain different equations of motion and different energy spectra. (Author) 16 refs.

  1. Sensitivity to friction for primary explosives

    International Nuclear Information System (INIS)

    Matyáš, Robert; Šelešovský, Jakub; Musil, Tomáš

    2012-01-01

    Highlights: ► The friction sensitivity of 14 samples of primary explosives was determined. ► The same apparatus (small scale BAM) and the same method (probit analysis) was used. ► The crystal shapes and sizes were documented with microscopy. ► Almost all samples are less sensitive than lead azide, which is commercially used. ► The organic peroxides (TATP, DADP, HMTD) are not as sensitive as often reported. - Abstract: The sensitivity to friction for a selection of primary explosives has been studied using a small BAM friction apparatus. The probit analysis was used for the construction of a sensitivity curve for each primary explosive tested. Two groups of primary explosives were chosen for measurement (a) the most commonly used industrially produced primary explosives (e.g. lead azide, tetrazene, dinol, lead styphnate) and (b) the most produced improvised primary explosives (e.g. triacetone triperoxide, hexamethylenetriperoxide diamine, mercury fulminate, acetylides of heavy metals). A knowledge of friction sensitivity is very important for determining manipulation safety for primary explosives. All the primary explosives tested were carefully characterised (synthesis procedure, shape and size of crystals). The sensitivity curves obtained represent a unique set of data, which cannot be found anywhere else in the available literature.

  2. Sensitivity to friction for primary explosives

    Energy Technology Data Exchange (ETDEWEB)

    Matyas, Robert, E-mail: robert.matyas@upce.cz [Institute of Energetic Materials, Faculty of Chemical Technology, University of Pardubice, Pardubice 532 10 (Czech Republic); Selesovsky, Jakub; Musil, Tomas [Institute of Energetic Materials, Faculty of Chemical Technology, University of Pardubice, Pardubice 532 10 (Czech Republic)

    2012-04-30

    Highlights: Black-Right-Pointing-Pointer The friction sensitivity of 14 samples of primary explosives was determined. Black-Right-Pointing-Pointer The same apparatus (small scale BAM) and the same method (probit analysis) was used. Black-Right-Pointing-Pointer The crystal shapes and sizes were documented with microscopy. Black-Right-Pointing-Pointer Almost all samples are less sensitive than lead azide, which is commercially used. Black-Right-Pointing-Pointer The organic peroxides (TATP, DADP, HMTD) are not as sensitive as often reported. - Abstract: The sensitivity to friction for a selection of primary explosives has been studied using a small BAM friction apparatus. The probit analysis was used for the construction of a sensitivity curve for each primary explosive tested. Two groups of primary explosives were chosen for measurement (a) the most commonly used industrially produced primary explosives (e.g. lead azide, tetrazene, dinol, lead styphnate) and (b) the most produced improvised primary explosives (e.g. triacetone triperoxide, hexamethylenetriperoxide diamine, mercury fulminate, acetylides of heavy metals). A knowledge of friction sensitivity is very important for determining manipulation safety for primary explosives. All the primary explosives tested were carefully characterised (synthesis procedure, shape and size of crystals). The sensitivity curves obtained represent a unique set of data, which cannot be found anywhere else in the available literature.

  3. [Sensitization to chymopapain in patients treated with chemonucleolysis].

    Science.gov (United States)

    García-Ortega, P; Ramírez Ferreiras, W; Sancho, A; Urías, S; Cisteró, A

    1991-03-23

    Chemonucleolysis (intradisk administration of chymopapain) is a procedure to treat intervertebral disk hernia. Recently, its use has been questioned due to the development of anaphylactic reactions in patients sensitized to chymopapain. The prevalence of sensitization to chymopapain has been evaluated before and after chemonucleolysis, and the possibility to establish risk groups through the allergy history has been assessed. 104 consecutive patients who were candidates to chemonucleolysis were evaluated with an allergy questionnaire, cutaneous tests to aeroallergens and to chymopapain, and chymopapain-specific IgE. The two latter tests were repeated one month after chemonucleolysis. Only 2 patients (1.9%) showed evidence of chymopapain sensitization before the procedure. Sixteen patients (16%) were sensitized after chemonucleolysis. None of the possible risk factors evaluated in the allergy questionnaire (atopy, drug allergy, papaya occupational exposure or use of additives, cosmetics or drugs containing papaine) were significantly related with the risk of sensitization to chymopapain. The prevalence of chymopapain sensitization in the study group was low. The allergy questionnaire (atopy, drug allergy, use of papaya, occupational history did not identify sensitized patients. Cutaneous tests and specific IgE are the best method to detect chymopapain sensitization. The remarkable rate of sensitization after chemonucleolysis may partially limit the usefulness of the procedure.

  4. Tuned cavity magnetometer sensitivity.

    Energy Technology Data Exchange (ETDEWEB)

    Okandan, Murat; Schwindt, Peter

    2009-09-01

    We have developed a high sensitivity (sensitivity levels.

  5. Cobalt sensitization and dermatitis

    DEFF Research Database (Denmark)

    Thyssen, Jacob P

    2012-01-01

    : This clinical review article presents clinical and scientific data on cobalt sensitization and dermatitis. It is concluded that cobalt despite being a strong sensitizer and a prevalent contact allergen to come up on patch testing should be regarded as a very complex metal to test with. Exposure...

  6. Multiple chemical sensitivity

    DEFF Research Database (Denmark)

    Tran, Marie Thi Dao; Arendt-Nielsen, Lars; Kupers, Ron

    2013-01-01

    BACKGROUND: Multiple Chemical Sensitivity (MCS) is a chronic condition characterized by recurrent, non-specific symptoms in response to chemically unrelated exposures in non-toxic concentrations. Although the pathophysiology of MCS remains unknown, central sensitization may be an important factor...

  7. Assessing Sensitiveness to Transport

    DEFF Research Database (Denmark)

    Lieb, Christoph; Suter, Stefan; Sánchez, Alfredo

    Summary The EU-project ASSET (ASessing SEnsitiveness to Transport) aims at developing and implementing a concise concept to assess transport sensitive areas (TSA) in a European context, i.e. areas in which transport leads to more serious impacts than in other areas. The aim of work package 2 (WP2...

  8. Imaging procedures in spinal infectious diseases

    International Nuclear Information System (INIS)

    Rodiek, S.O.

    2001-01-01

    A targeted successful treatment of spinal infectious diseases requires clinical and laboratory data that are completed by the contribution of imaging procedures. Neuroimaging only provides essential informations on the correct topography, localisation, acuity and differential diagnosis of spinal infectious lesions. MRI with its sensitivity concerning soft tissue lesions is a useful tool in detecting infectious alterations of spinal bone marrow, intervertebral disks, leptomeninges and the spinal cord itself. Crucial imaging patterns of typical spinal infections are displayed and illustrated by clinical case studies. We present pyogenic, granulomatous and postoperative variants of spondylodicitis, spinal epidural abscess, spinal meningitis and spinal cord infections. The importance of intravenous contrastmedia application is pointed out. (orig.) [de

  9. Finnish Teachers’ Ethical Sensitivity

    Directory of Open Access Journals (Sweden)

    Elina Kuusisto

    2012-01-01

    Full Text Available The study examined the ethical sensitivity of Finnish teachers (=864 using a 28-item Ethical Sensitivity Scale Questionnaire (ESSQ. The psychometric qualities of this instrument were analyzed, as were the differences in self-reported ethical sensitivity between practicing and student teachers and teachers of different subjects. The results showed that the psychometric qualities of the ESSQ were satisfactory and enabled the use of an explorative factor analysis. All Finnish teachers rated their level of ethical sensitivity as high, which indicates that they had internalized the ethical professionalism of teaching. However, practicing teachers’ assessments were higher than student teachers’. Moreover, science as a subject was associated with lower self-ratings of ethical sensitivity.

  10. Insulin sensitivity and albuminuria

    DEFF Research Database (Denmark)

    Pilz, Stefan; Rutters, Femke; Nijpels, Giel

    2014-01-01

    OBJECTIVE: Accumulating evidence suggests an association between insulin sensitivity and albuminuria, which, even in the normal range, is a risk factor for cardiovascular diseases. We evaluated whether insulin sensitivity is associated with albuminuria in healthy subjects. RESEARCH DESIGN...... AND METHODS: We investigated 1,415 healthy, nondiabetic participants (mean age 43.9 ± 8.3 years; 54.3% women) from the RISC (Relationship between Insulin Sensitivity and Cardiovascular Disease) study, of whom 852 participated in a follow-up examination after 3 years. At baseline, insulin sensitivity...... was assessed by hyperinsulinemic-euglycemic clamps, expressed as the M/I value. Oral glucose tolerance test-based insulin sensitivity (OGIS), homeostasis model assessment of insulin resistance (HOMA-IR), and urinary albumin-to-creatinine ratio (UACR) were determined at baseline and follow-up. RESULTS...

  11. Automated sensitivity analysis using the GRESS language

    International Nuclear Information System (INIS)

    Pin, F.G.; Oblow, E.M.; Wright, R.Q.

    1986-04-01

    An automated procedure for performing large-scale sensitivity studies based on the use of computer calculus is presented. The procedure is embodied in a FORTRAN precompiler called GRESS, which automatically processes computer models and adds derivative-taking capabilities to the normal calculated results. In this report, the GRESS code is described, tested against analytic and numerical test problems, and then applied to a major geohydrological modeling problem. The SWENT nuclear waste repository modeling code is used as the basis for these studies. Results for all problems are discussed in detail. Conclusions are drawn as to the applicability of GRESS in the problems at hand and for more general large-scale modeling sensitivity studies

  12. Application of safeguards procedures

    International Nuclear Information System (INIS)

    1977-01-01

    The earliest applications of safeguards procedures took place in a political and technical climate far different from that of today. In the early 1960's there was a fear of the proliferation possibilities which could arise as more and more countries acquired nuclear power plants. Today nuclear power is being produced in some 20 countries without resulting in nuclear weapons proliferation. The export of equipment and technology for the nuclear fuel cycle, however, has become the subject of current concern. In view of these developments, it is not surprising that techniques in the application of safeguards have also changed. In order to appreciate the nature of these changes, it is important to be aware of the original general attitude towards the technical problems of safeguards applications. Originally, the common attitude was that the objectives of safeguards were self-evident and the methods, while in need of development, were known at least in outline. Today, it has become evident that before a safeguards procedure can be applied, the objectives must first be carefully defined, and the criteria against which success in meeting those objectives can be measured must also be developed. In line with this change, a significant part of the effort of the safeguards inspectorate is concerned with work preliminary and subsequent to the actual inspection work in the field. Over the last two years, for example, a considerable part of the work of experienced safeguards staff has been spent in analysing the possibilities of diverting material at each facility to be safeguarded. These analyses are carried out in depth by a 'facility officer' and are subjected to constructive criticism by teams composed of staff responsible for similar types of facilities as well as other technical experts. The analyses consider the measures currently considered practicable, to meet the diversion possibilities and where necessary list the development work needed to overcome any present

  13. Flow-based intrusion detection

    NARCIS (Netherlands)

    Sperotto, Anna

    2010-01-01

    The spread of 1-10Gbps technology has in recent years paved the way to a flourishing landscape of new, high-bandwidth Internet services. As users, we depend on the Internet in our daily life for simple tasks such as checking e-mails, but also for managing private and financial information. However,

  14. Flow-based Compromise Detection

    NARCIS (Netherlands)

    Hofstede, R.J.

    2016-01-01

    Brute-force attacks are omnipresent and manyfold on the Internet, and aim at compromising user accounts by issuing large numbers of authentication attempts on applications and daemons. Widespread targets of such attacks are Secure SHell (SSH) and Web applications, for example. The impact of

  15. Flow-Based Intrusion Detection

    NARCIS (Netherlands)

    Sperotto, Anna; Pras, Aiko

    The spread of 1-10 Gbps technology has in recent years paved the way to a flourishing landscape of new, high-bandwidth Internet services.At the same time, we have also observed increasingly frequent and widely diversified attacks. To this threat, the research community has answered with a growing

  16. 14 CFR 11.35 - Does FAA include sensitive security information and proprietary information in the Federal Docket...

    Science.gov (United States)

    2010-01-01

    ... RULEMAKING PROCEDURES Rulemaking Procedures General § 11.35 Does FAA include sensitive security information and proprietary information in the Federal Docket Management System (FDMS)? (a) Sensitive security information. You should not submit sensitive security information to the rulemaking docket, unless you are...

  17. BWR emergency procedure guidelines

    International Nuclear Information System (INIS)

    Post, J.S.; Karner, E.F.; Stratman, R.A.

    1984-01-01

    This chapter describes plans for dealing with reactor accidents developed by the Boiling Water Reactor (BWR) Owners' Group in response to post-Three Mile Island US NRC requirements. The devised Emergency Procedure Guidelines (EPGs), applicable to all BWRs, are symptom-based rather than event-based. According to the EPGs, the operator does not need to identify what event is occurring in the plant in order to decide what action to take, but need only observe the symptoms (values and trends of key control parameters) which exist and take appropriate action to control these symptoms. The original objective was to provide reactor operator guidance in responding to a small break loss-of-coolant accident (LOCA), but subsequent revisions have included other types of reactor accidents. Topics considered include the reactor pressure vessel (RPV) control guideline, the primary containment control guideline, the secondary containment control guideline, the radioactivity release control guideline, multiple failures vs. the design basis, safe limits vs. technical specifications, the technical status, licensing, and implementation. The EPGs are based upon maintaining both adequate core cooling and primary containment integrity

  18. Automated emergency operating procedures

    International Nuclear Information System (INIS)

    Perez-Ramirez, G.; Nelson, P.F.

    1990-01-01

    This paper describes the development of a training tool for the symptom oriented emergency operating procedures used at the Laguna Verde Nuclear Power Plant. EOPs and operator training are intended to assist the operator for managing accident situations. A prototype expert system based on the EOPs has been developed for operator training. The demonstration expert system was developed using a commercial shell. The knowledge base consists of two parts. The specific operator actions to be executed for 5 selected accident sequences and the EOPs steps for the reactor pressure vessel control of the water level, pressure, and power. The knowledge is expressed in the form of IF-THEN production rules. A typical training session will display a set of conditions and will prompt the trainee to indicate the appropriate step to perform. This mode will guide the trainee through selected accident sequences. A second mode of the expert system will prompt the trainee for the current plant conditions and the expert system will respond with the EOPs which are required to be performed under these conditions. This allows the trainee to study What if situations

  19. Computer software review procedures

    International Nuclear Information System (INIS)

    Mauck, J.L.

    1993-01-01

    This article reviews the procedures which are used to review software written for computer based instrumentation and control functions in nuclear facilities. The utilization of computer based control systems is becoming much more prevalent in such installations, in addition to being retrofit into existing systems. Currently, the Nuclear Regulatory System uses Regulatory Guide 1.152, open-quotes Criteria for Programmable Digital Computer System Software in Safety-Related Systems of Nuclear Power Plantsclose quotes and ANSI/IEEE-ANS-7-4.3.2-1982, open-quotes Application Criteria for Programmable Digital Computer Systems in Safety Systems of Nuclear Power Generating Stationsclose quotes for guidance when performing reviews of digital systems. There is great concern about the process of verification and validation of these codes, so when inspections are done of such systems, inspectors examine very closely the processes which were followed in developing the codes, the errors which were detected, how they were found, and the analysis which went into tracing down the causes behind the errors to insure such errors were not propagated again in the future

  20. [Costing nuclear medicine diagnostic procedures].

    Science.gov (United States)

    Markou, Pavlos

    2005-01-01

    To the Editor: Referring to a recent special report about the cost analysis of twenty-nine nuclear medicine procedures, I would like to clarify some basic aspects for determining costs of nuclear medicine procedure with various costing methodologies. Activity Based Costing (ABC) method, is a new approach in imaging services costing that can provide the most accurate cost data, but is difficult to perform in nuclear medicine diagnostic procedures. That is because ABC requires determining and analyzing all direct and indirect costs of each procedure, according all its activities. Traditional costing methods, like those for estimating incomes and expenses per procedure or fixed and variable costs per procedure, which are widely used in break-even point analysis and the method of ratio-of-costs-to-charges per procedure may be easily performed in nuclear medicine departments, to evaluate the variability and differences between costs and reimbursement - charges.

  1. Radiation dose during angiographic procedures

    International Nuclear Information System (INIS)

    Lavoie, Ch.; Rasuli, P.

    2001-01-01

    The use of angiographic procedures is becoming more prevalent as new techniques and equipment are developed. There have been concerns in the scientific community about the level of radiation doses received by patients, and indirectly by staff, during some of these radiological procedures. The purpose of this study was to assess the level of radiation dose from angiographic procedures to patient at the Ottawa Hospital, General Campus. Radiation dose measurements, using Thermo-Luminescent Dosimeters (TLDs), were performed on more than 100 patients on various procedures. The results show that while the patient dose from the great majority of angiographic procedures is less than 2 Gy, a significant number of procedures, especially interventional procedures may have doses greater than 2 Gy and may lead to deterministic effects. (author)

  2. Administrative Procedure Act and mass procedures (illustrated by the nuclear licensing procedure)

    International Nuclear Information System (INIS)

    Naumann, R.

    1977-01-01

    The report deals with the administrative procedure law of 25.5.76 of the Fed. Government, esp. with its meaning for the administrative procedures for the permission for nuclear power plants, as fas ar so-called mass procedures are concerned. (UN) [de

  3. Improved sensitivity of nucleic acid amplification for rapid diagnosis of tuberculous meningitis

    DEFF Research Database (Denmark)

    Johansen, Isik Somuncu; Lundgren, Bettina; Tabak, Fehmi

    2004-01-01

    was adjusted from the recommended value of 3,400 to 1,000, the sensitivity of the modified procedure increased to 84.7%, with unchanged specificity. Results were obtained in 3 to 4 h. The new pretreatment procedure with the ProbeTec assay described here provides a rapid, simple, and sensitive tool...

  4. Safeguards management inspection procedures

    International Nuclear Information System (INIS)

    Barth, M.J.; Dunn, D.R.

    1984-08-01

    The objective of this inspection module is to independently assess the contributions of licensee management to overall safeguards systems performance. The inspector accomplishes this objective by comparing the licensee's safeguards management to both the 10 CFR, parts 70 and 73, requirements and to generally accepted management practices. The vehicle by which this comparison is to be made consists of assessment questions and key issues which point the inspector to areas of primary concern to the NRC and which raise additional issues for the purpose of exposing management ineffectiveness. Further insight into management effectiveness is obtained through those assessment questions specifically directed toward the licensee's safeguards system performance. If the quality of the safeguards is poor, then the inspector should strongly suspect that management's role is ineffective and should attempt to determine management's influence (or lack thereof) on the underlying safeguards deficiencies. (The converse is not necessarily true, however.) The assessment questions in essence provide an opportunity for the inspector to identify, to single out, and to probe further, questionable management practices. Specific issues, circumstances, and concerns which point to questionable or inappropriate practices should be explicitly identified and referenced against the CFR and the assessment questions. The inspection report should also explain why the inspector feels certain management practices are poor, counter to the CFR, and/or point to ineffecive management. Concurrent with documenting the inspection results, the inspector should provide recommendations for alleviating observed management practices that are detrimental to effective safeguards. The recommendations could include: specific changes in the practices of the licensee, followup procedures on the part of NRC, and proposed license changes

  5. AGREED-UPON PROCEDURES, PROCEDURES FOR AUDITING EUROPEAN GRANTS

    Directory of Open Access Journals (Sweden)

    Daniel Petru VARTEIU

    2016-12-01

    The audit of EU-funded projects is an audit based on agreed-upon procedures, which are established by the Managing Authority or the Intermediate Body. Agreed-upon procedures can be defined as engagements made in accordance with ISRS 4400, applicable to agreed-upon procedures, where the auditor undertakes to carry out the agreed-upon procedures and issue a report on factual findings. The report provided by the auditor does not express any assurance. It allows users to form their own opinions about the conformity of the expenses with the project budget as well as the eligibility of the expenses.

  6. Developing cultural sensitivity

    DEFF Research Database (Denmark)

    Ruddock, Heidi; Turner, deSalle

    2007-01-01

    . Background. Many countries are becoming culturally diverse, but healthcare systems and nursing education often remain mono-cultural and focused on the norms and needs of the majority culture. To meet the needs of all members of multicultural societies, nurses need to develop cultural sensitivity......Title. Developing cultural sensitivity: nursing students’ experiences of a study abroad programme Aim. This paper is a report of a study to explore whether having an international learning experience as part of a nursing education programme promoted cultural sensitivity in nursing students...... and incorporate this into caregiving. Method. A Gadamerian hermeneutic phenomenological approach was adopted. Data were collected in 2004 by using in-depth conversational interviews and analysed using the Turner method. Findings. Developing cultural sensitivity involves a complex interplay between becoming...

  7. Spontaneous baroreflex sensitivity

    DEFF Research Database (Denmark)

    Barthel, Petra; Bauer, Axel; Müller, Alexander

    2012-01-01

    Low baroreflex sensitivity (BRS) indicates poor prognosis after acute myocardial infarction. Noninvasive BRS assessment is complicated by nonstationarities and noise in electrocardiogram and pressure signals. Phase-rectified signal averaging is a novel signal processing technology overcoming thes...

  8. Resonance sensitivity of hydropower and pumping stations

    Energy Technology Data Exchange (ETDEWEB)

    Popescu, M.; Halanay, A.

    1984-09-01

    Comparative analysis of resonance diagrams for several hydropower and pumping stations with surge tanks and air chambers shows large differences in the maximum resonance pressures. A strategy is advocated which consists of hydraulic resonance computations coupled with practical surveillance measures during the operation of resonance sensitive hydraulic systems. A fundamental hydraulic scheme is considered consisting of a reservoir, a pressure tunnel, a surge tank, a penstock and a turbine combined into a hydropower station. It is suggested that for each hydraulic surge system it is necessary to carry out special resonance analyses following the normal procedure to obtain the resonance sensitivity. For hydraulic systems which are resonance sensitive, mechanical electronic equipment should be used to measure non-stationary pressures of the water in the conduit as a way of continuous surveillance during functioning. 6 references, 6 figures.

  9. Aesthetic procedures in office practice.

    Science.gov (United States)

    Small, Rebecca

    2009-12-01

    Since the approval of botulinum toxin, dermal fillers, and lasers for cosmetic use, minimally invasive aesthetic procedures have rapidly become the treatments of choice for age-related facial changes. In the past 10 years, aesthetic procedures have increased nearly five-fold. Of the 10.2 million aesthetic treatments performed in 2008, 83 percent were minimally invasive procedures. Botulinum toxin and dermal filler injections, laser hair reduction, chemical peels, laser skin resurfacing, microdermabrasion, and intense pulsed light photorejuvenation were the most commonly performed procedures in 2008. These procedures are effective and associated with minimal discomfort, and they have a low incidence of adverse effects and short recovery times. High patient and physician satisfaction have contributed to their growing popularity and availability in the primary care setting. As patient demand for aesthetic treatments increases, family physicians should be familiar with common minimally invasive aesthetic procedures when advising patients or incorporating aesthetic care into office practice.

  10. Characteristics of Mobile Payment Procedures

    OpenAIRE

    Kreyer, Nina; Pousttchi, Key; Turowski, Klaus

    2002-01-01

    Companies are not going to invest into the development of innovative applications or services unless these can be charged for appropriately. Thus, the existence of standardized and widely accepted mobile payment procedures is crucial for successful business-to-customer mobile commerce. The acceptance of mobile payment procedures depends on costs, security and convenience issues. For the latter, it is important that a procedure can be used over the different payment scenarios mobile commerce, ...

  11. Multitarget global sensitivity analysis of n-butanol combustion.

    Science.gov (United States)

    Zhou, Dingyu D Y; Davis, Michael J; Skodje, Rex T

    2013-05-02

    A model for the combustion of butanol is studied using a recently developed theoretical method for the systematic improvement of the kinetic mechanism. The butanol mechanism includes 1446 reactions, and we demonstrate that it is straightforward and computationally feasible to implement a full global sensitivity analysis incorporating all the reactions. In addition, we extend our previous analysis of ignition-delay targets to include species targets. The combination of species and ignition targets leads to multitarget global sensitivity analysis, which allows for a more complete mechanism validation procedure than we previously implemented. The inclusion of species sensitivity analysis allows for a direct comparison between reaction pathway analysis and global sensitivity analysis.

  12. Applications of sensitivity function to dosimetric data adjustments

    International Nuclear Information System (INIS)

    Nakazawa, Masaharu

    1984-01-01

    Sensitivity functions are applied to the dosimetric field in the spectrum unfolding technique, also called as the data adjustment technique which are statistical estimation procedures of the neutron spectrum or relating dosimetric quantities basing on the reaction-rate data measurements. Using the practical formulae and numerical examples of the sensitivity functions in the dosimetric data adjustments, two comments are made that (1) present sensitivity values are highly depending on the initial spectrum inputs and (2) more attention should be paid to the dependency of the sensitivity on the very uncertain covariance data inputs of the initial neutron spectrum. (author)

  13. Coding for urologic office procedures.

    Science.gov (United States)

    Dowling, Robert A; Painter, Mark

    2013-11-01

    This article summarizes current best practices for documenting, coding, and billing common office-based urologic procedures. Topics covered include general principles, basic and advanced urologic coding, creation of medical records that support compliant coding practices, bundled codes and unbundling, global periods, modifiers for procedure codes, when to bill for evaluation and management services during the same visit, coding for supplies, and laboratory and radiology procedures pertinent to urology practice. Detailed information is included for the most common urology office procedures, and suggested resources and references are provided. This information is of value to physicians, office managers, and their coding staff. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Acquisition Policy and Procedures Program

    National Research Council Canada - National Science Library

    2001-01-01

    This Instruction establishes policies, responsibilities, and procedures for the procurement of goods and services to include supplies, equipment, publications, furniture, and information technology...

  15. Electronic Procedures for Medical Operations

    Science.gov (United States)

    2015-01-01

    Electronic procedures are replacing text-based documents for recording the steps in performing medical operations aboard the International Space Station. S&K Aerospace, LLC, has developed a content-based electronic system-based on the Extensible Markup Language (XML) standard-that separates text from formatting standards and tags items contained in procedures so they can be recognized by other electronic systems. For example, to change a standard format, electronic procedures are changed in a single batch process, and the entire body of procedures will have the new format. Procedures can be quickly searched to determine which are affected by software and hardware changes. Similarly, procedures are easily shared with other electronic systems. The system also enables real-time data capture and automatic bookmarking of current procedure steps. In Phase II of the project, S&K Aerospace developed a Procedure Representation Language (PRL) and tools to support the creation and maintenance of electronic procedures for medical operations. The goal is to develop these tools in such a way that new advances can be inserted easily, leading to an eventual medical decision support system.

  16. Pollutant Assessments Group procedures manual: Volume 2, Technical procedures

    Energy Technology Data Exchange (ETDEWEB)

    1992-03-01

    This is volume 2 of the manuals that describes the technical procedures currently in use by the Pollution Assessments Group. This manual incorporates new developments in hazardous waste assessment technology and administrative policy. Descriptions of the equipment, procedures and operations of such things as radiation detection, soil sampling, radionuclide monitoring, and equipment decontamination are included in this manual. (MB)

  17. WHAT IF (Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    Iulian N. BUJOREANU

    2011-01-01

    Full Text Available Sensitivity analysis represents such a well known and deeply analyzed subject that anyone to enter the field feels like not being able to add anything new. Still, there are so many facets to be taken into consideration.The paper introduces the reader to the various ways sensitivity analysis is implemented and the reasons for which it has to be implemented in most analyses in the decision making processes. Risk analysis is of outmost importance in dealing with resource allocation and is presented at the beginning of the paper as the initial cause to implement sensitivity analysis. Different views and approaches are added during the discussion about sensitivity analysis so that the reader develops an as thoroughly as possible opinion on the use and UTILITY of the sensitivity analysis. Finally, a round-up conclusion brings us to the question of the possibility of generating the future and analyzing it before it unfolds so that, when it happens it brings less uncertainty.

  18. Sensitivity Analysis Without Assumptions.

    Science.gov (United States)

    Ding, Peng; VanderWeele, Tyler J

    2016-05-01

    Unmeasured confounding may undermine the validity of causal inference with observational studies. Sensitivity analysis provides an attractive way to partially circumvent this issue by assessing the potential influence of unmeasured confounding on causal conclusions. However, previous sensitivity analysis approaches often make strong and untestable assumptions such as having an unmeasured confounder that is binary, or having no interaction between the effects of the exposure and the confounder on the outcome, or having only one unmeasured confounder. Without imposing any assumptions on the unmeasured confounder or confounders, we derive a bounding factor and a sharp inequality such that the sensitivity analysis parameters must satisfy the inequality if an unmeasured confounder is to explain away the observed effect estimate or reduce it to a particular level. Our approach is easy to implement and involves only two sensitivity parameters. Surprisingly, our bounding factor, which makes no simplifying assumptions, is no more conservative than a number of previous sensitivity analysis techniques that do make assumptions. Our new bounding factor implies not only the traditional Cornfield conditions that both the relative risk of the exposure on the confounder and that of the confounder on the outcome must satisfy but also a high threshold that the maximum of these relative risks must satisfy. Furthermore, this new bounding factor can be viewed as a measure of the strength of confounding between the exposure and the outcome induced by a confounder.

  19. Managing a sensitive project

    International Nuclear Information System (INIS)

    Etcheber, Pascal

    1998-01-01

    A 'sensitive' project needs to be managed differently from a 'normal' project. This statement might seem simple enough. However, it does not seem to be a simple task to prove it in twenty minutes. This paper is an attempt to share with the audience some of the experiences the company had dealing with sensitive projects. It describes what a sensitive project is, though of all people, the 'nuclear' should know. Then the common mistakes are described, that are made in the hoping that some personal experiences are recognised. Finally the company's strategy is shown, how we foster third party support and the main tools to be used. Ultimately, success is ensured by having a sufficient quantity of allies. A sensitive project does not die because it has too many opponents, but because it has too few allies. Finding and helping allies to act is the thrust of our activity. It enables sensitive projects which deserve to succeed to do so, where traditional management fails miserably

  20. Improving the efficiency of aerodynamic shape optimization procedures

    Science.gov (United States)

    Burgreen, Greg W.; Baysal, Oktay; Eleshaky, Mohamed E.

    1992-01-01

    The computational efficiency of an aerodynamic shape optimization procedure which is based on discrete sensitivity analysis is increased through the implementation of two improvements. The first improvement involves replacing a grid point-based approach for surface representation with a Bezier-Bernstein polynomial parameterization of the surface. Explicit analytical expressions for the grid sensitivity terms are developed for both approaches. The second improvement proposes the use of Newton's method in lieu of an alternating direction implicit (ADI) methodology to calculate the highly converged flow solutions which are required to compute the sensitivity coefficients. The modified design procedure is demonstrated by optimizing the shape of an internal-external nozzle configuration. A substantial factor of 8 decrease in computational time for the optimization process was achieved by implementing both of the design improvements.

  1. Evaluation of sensitivity and specificity of a standardized procedure using different reagents for the detection of lupus anticoagulants. The Working Group on Hemostasis of the Société Française de Biologie Clinique and for the Groupe d'Etudes sur I'Hémostase et la Thrombose.

    Science.gov (United States)

    Goudemand, J; Caron, C; De Prost, D; Derlon, A; Borg, J Y; Sampol, J; Sié, P

    1997-02-01

    This study was designed to test the sensitivity and specificity of a combination of 3 phospholipid-dependent assays performed with various reagents, for the detection of lupus anticoagulant (LA). Plasmas containing an LA (n = 56) or displaying various confounding pathologies [58 intrinsic pathway factor deficiencies, 9 factor VIII inhibitors, 28 plasmas from patients treated with an oral anticoagulant (OAC)] were selected. In a first step, the efficiency of each assay and reagent was assessed using the Receiving Operating Characteristic (ROC) method. Optimal cut-offs providing both sensitivity and specificity > or = 80% were determined. The APTT assay and most of the phospholipid neutralization assays failed to discriminate factor VIII inhibitors from LA. In a second step, using the optimal cut-offs determined above, the results of all the possible combinations of the 3 assays performed with 4 different reagents were analyzed. Thirteen combinations of reagents allowed > or = 80% of plasmas of each category (LA, factor deficiency or OAC) to be correctly classified (3/3 positive test results in LA-containing plasmas and 0/3 positive results in LA-negative samples).

  2. Green power production by co-gasification of biomass in coal-fired oxygen-blown entrained-flow based IGCC processes

    Energy Technology Data Exchange (ETDEWEB)

    Van Ree, R; Korbee, R; De Smidt, R P; Jansen, D [ECN Fuels Conversion and Environment, Petten (Netherlands); Baumann, H R; Ullrich, N [Krupp Uhde, Dortmund (Germany); Haupt, G; Zimmerman, [Siemens, Erlangen (Germany)

    1998-11-01

    The use of coal for large scale power production meets a growing environmental concern. In spite of the fact that clean coal conversion technologies integrated with high-efficiency power production facilities, such as IGCC, are developed, the aim for sustainable development strives for a power production system based on renewable energy sources. One of the most promising renewable energy sources that can be used in the Netherlands is biomass, i.e. organic waste materials and/or energy crops. To accelerate the introduction of this material, in a technical and economically acceptable way, co-gasification with fossil fuels, in particular coal, in large scale IGCC processes is considered. In this paper the technical feasibility, economic profitability, and environmental acceptability of co-gasification of biomass in coal-fired oxygen-blown entrained-flow based IGM is discussed. Both a base-case coal-fired oxygen-blown entrained-flow based IGCC process - showing strong resemblance to the Puertollano IGCC plant in Spain - and three co-gasification concepts, viz.: (1) a concept with separate dry coal and biomass feeding systems, (2) a concept with a combined dry coal/biomass-derived pyrolysis char feeding system, and (3) a concept with parallel biomass pre-treatment/gasification and combined fuel gas clean-up/power production, were defined for further consideration. The base-case system and the co-gasification concepts as well are modelled in the flowsheet simulation package ASPEN{sup +}. Steady-state integral system calculations resulted in an overall net electrical plant efficiency for the base-case system of 50. 1 %LHV (48.3 %HHV). Replacing about 10 % of the total thermal plant input (coal) by biomass (willow) resulted in a decrease of the overall net electrical plant efficiency of 1.4 to 2.1 %-points LHV, avoided specific CO2 emissions of 40-49 g/kWh{sub e}, and total avoided CO2 emissions of about 129 to 159 kt/a, all depending on the co-gasification concept

  3. Sensitizing properties of proteins

    DEFF Research Database (Denmark)

    Poulsen, Lars K.; Ladics, Gregory S; McClain, Scott

    2014-01-01

    The scope of allergy risk is diverse considering the myriad ways in which protein allergenicity is affected by physiochemical characteristics of proteins. The complexity created by the matrices of foods and the variability of the human immune system add additional challenges to understanding...... the relationship between sensitization potential and allergy disease. To address these and other issues, an April 2012 international symposium was held in Prague, Czech Republic, to review and discuss the state-of-the-science of sensitizing properties of protein allergens. The symposium, organized by the Protein...... Allergenicity Technical Committee of the International Life Sciences Institute's Health and Environmental Sciences Institute, featured presentations on current methods, test systems, research trends, and unanswered questions in the field of protein sensitization. A diverse group of over 70 interdisciplinary...

  4. Evaluation of a lateral flow-based technology card for blood typing using a simplified protocol in a model of extreme blood sampling conditions.

    Science.gov (United States)

    Clavier, Benoît; Pouget, Thomas; Sailliol, Anne

    2018-02-01

    Life-threatening situations requiring blood transfusion under extreme conditions or in remote and austere locations, such as the battlefield or in traffic accidents, would benefit from reliable blood typing practices that are easily understood by a nonscientist or nonlaboratory technician and provide quick results. A simplified protocol was developed for the lateral flow-based device MDmulticard ABO-D-Rh subgroups-K. Its performance was compared to a reference method (PK7300, Beckman Coulter) in native blood samples from donors. The method was tested on blood samples stressed in vitro as a model of hemorrhage cases (through hemodilution using physiologic serum) and dehydration (through hemoconcentration by removing an aliquot of plasma after centrifugation), respectively. A total of 146 tests were performed on 52 samples; 126 in the hemodilution group (42 for each native, diluted 1/2, and diluted 1/4 samples) and 20 in the hemoconcentration group (10 for each native and 10% concentrated samples). Hematocrit in the tested samples ranged from 9.8% to 57.6% while hemoglobin levels ranged from 3.2 to 20.1 g/dL. The phenotype profile detected with the MDmulticard using the simplified protocol resulted in 22 A, seven B, 20 O, and three AB, of which nine were D- and five were Kell positive. No discrepancies were found with respect to the results obtained with the reference method. The simplified protocol for MDmulticard use could be considered a reliable method for blood typing in extreme environment or emergency situations, worsened by red blood cell dilution or concentration. © 2017 AABB.

  5. Proof Rules for Recursive Procedures

    NARCIS (Netherlands)

    Hesselink, Wim H.

    1993-01-01

    Four proof rules for recursive procedures in a Pascal-like language are presented. The main rule deals with total correctness and is based on results of Gries and Martin. The rule is easier to apply than Martin's. It is introduced as an extension of a specification format for Pascal-procedures, with

  6. Laparoscopic reversal of Hartmann's procedure

    DEFF Research Database (Denmark)

    Svenningsen, Peter Olsen; Bulut, Orhan; Jess, Per

    2010-01-01

    of Hartmann's procedure as safely as in open surgery and with a faster recovery, shorter hospital stay and less blood loss despite a longer knife time. It therefore seems reasonable to offer patients a laparoscopic procedure at departments which are skilled in laparoscopic surgery and use it for standard...

  7. Developing Competency in Payroll Procedures

    Science.gov (United States)

    Jackson, Allen L.

    1975-01-01

    The author describes a sequence of units that provides for competency in payroll procedures. The units could be the basis for a four to six week minicourse and are adaptable, so that the student, upon completion, will be able to apply his learning to any payroll procedures system. (Author/AJ)

  8. Failure to Follow Written Procedures

    Science.gov (United States)

    2017-12-01

    Most tasks in aviation have a mandated written procedure to be followed specifically under the Code of Federal Regulations (CFR) Part 14, Section 43.13(a). However, the incidence of Failure to Follow Procedure (FFP) events continues to be a major iss...

  9. Procedure for taking physical inventories

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This session is intended to apprise one of the various aspects of procedures and routines that Exxon Nuclear uses with respect to its nuclear materials physical inventory program. The presentation describes how plant physical inventories are planned and taken. The description includes the planning and preparation for taking the inventory, the clean-out procedures for converting in-process material to measurable items, the administrative procedures for establishing independent inventory teams and for inventorying each inventory area, the verification procedures used to include previously measured tamper-safed items in the inventory, and lastly, procedures used to reconcile the inventory and calculate MUF (materials unaccounted for). The purpose of the session is to enable participants to: (1) understand the planning and pre-inventorty procedures and their importance; (2) understand the need for and the required intensity of clean-out procedures; (3) understand how inventory teams are formed, and how the inventory is conducted; (4) understand the distinction between inventory previously measured tamper-safed items and other materials not so characterized; (5) understand the reconciliation procedures; and (6) calculate a MUF given the book and inventory results

  10. Screening sensitivity theory

    International Nuclear Information System (INIS)

    Oblow, E.M.; Perey, F.G.

    1984-01-01

    A comprehensive rigorous theory is developed for screening sensitivity coefficients in largescale modeling applications. The theory uses Bayesian inference and group theory to establish a probabilistic framework for solving an underdetermined system of linear equations. The underdetermined problem is directly related to statistical screening sensitivity theory as developed in recent years. Several examples of the new approach to screening are worked out in detail and comparisons are made with statistical approaches to the problem. The drawbacks of these latter methods are discussed at some length

  11. Highly Sensitive Optical Receivers

    CERN Document Server

    Schneider, Kerstin

    2006-01-01

    Highly Sensitive Optical Receivers primarily treats the circuit design of optical receivers with external photodiodes. Continuous-mode and burst-mode receivers are compared. The monograph first summarizes the basics of III/V photodetectors, transistor and noise models, bit-error rate, sensitivity and analog circuit design, thus enabling readers to understand the circuits described in the main part of the book. In order to cover the topic comprehensively, detailed descriptions of receivers for optical data communication in general and, in particular, optical burst-mode receivers in deep-sub-µm CMOS are presented. Numerous detailed and elaborate illustrations facilitate better understanding.

  12. Tinnitus sensitization: a neurophysiological pathway of chronic complex tinnitus.

    Science.gov (United States)

    Zenner, Hans P

    2006-01-01

    A novel neuro- and psychophysiological pathway for central cognition of tinnitus, i.e. tinnitus sensitization, is presented here. As a complement to the neurophysiological pathway for the conditioned reflex according to Jastreboff, which permits therapeutic procedures to bring about an extinction of the tinnitus (e.g. by the acoustic tinnitus retraining therapy), sensitization can be treated with procedures that act at the cognitive level. Since on the one hand therapeutic extinction procedures (e.g. the therapeutic application of sound) are still to be proven effective in controlled studies, while on the other cognitive interventions such as cognitive behavioral therapies have in fact acquired evidence level IIa in prospective studies, it is indeed appropriate to discuss whether the earlier neurophysiological model of a conditioned reflex is sufficient on its own, and whether in fact it needs to be complemented with the sensitization model.

  13. Differentiation of ileostomy from colostomy procedures: assessing the accuracy of current procedural terminology codes and the utility of natural language processing.

    Science.gov (United States)

    Vo, Elaine; Davila, Jessica A; Hou, Jason; Hodge, Krystle; Li, Linda T; Suliburk, James W; Kao, Lillian S; Berger, David H; Liang, Mike K

    2013-08-01

    Large databases provide a wealth of information for researchers, but identifying patient cohorts often relies on the use of current procedural terminology (CPT) codes. In particular, studies of stoma surgery have been limited by the accuracy of CPT codes in identifying and differentiating ileostomy procedures from colostomy procedures. It is important to make this distinction because the prevalence of complications associated with stoma formation and reversal differ dramatically between types of stoma. Natural language processing (NLP) is a process that allows text-based searching. The Automated Retrieval Console is an NLP-based software that allows investigators to design and perform NLP-assisted document classification. In this study, we evaluated the role of CPT codes and NLP in differentiating ileostomy from colostomy procedures. Using CPT codes, we conducted a retrospective study that identified all patients undergoing a stoma-related procedure at a single institution between January 2005 and December 2011. All operative reports during this time were reviewed manually to abstract the following variables: formation or reversal and ileostomy or colostomy. Sensitivity and specificity for validation of the CPT codes against the mastery surgery schedule were calculated. Operative reports were evaluated by use of NLP to differentiate ileostomy- from colostomy-related procedures. Sensitivity and specificity for identifying patients with ileostomy or colostomy procedures were calculated for CPT codes and NLP for the entire cohort. CPT codes performed well in identifying stoma procedures (sensitivity 87.4%, specificity 97.5%). A total of 664 stoma procedures were identified by CPT codes between 2005 and 2011. The CPT codes were adequate in identifying stoma formation (sensitivity 97.7%, specificity 72.4%) and stoma reversal (sensitivity 74.1%, specificity 98.7%), but they were inadequate in identifying ileostomy (sensitivity 35.0%, specificity 88.1%) and colostomy (75

  14. Genetics Home Reference: warfarin sensitivity

    Science.gov (United States)

    ... Email Facebook Twitter Home Health Conditions Warfarin sensitivity Warfarin sensitivity Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Warfarin sensitivity is a condition in which individuals have ...

  15. PAYMENT CAPACITY SENSITIVITY FACTORS

    Directory of Open Access Journals (Sweden)

    Daniel BRÎNDESCU – OLARIU

    2014-11-01

    The results of the study facilitate the determination and classification of the main sensitivity factors for the payment capacity at sample level, the establishment of general benchmarks for the payment capacity (as no such benchmarks currently exist in the Romanian literature and the identification of the mechanisms through which the variation of different factors impacts the payment capacity.

  16. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  17. Sensitization of Parker fittings

    International Nuclear Information System (INIS)

    Wilber, W.W.

    1985-09-01

    At your request, ferrules from 316 SS Parker-Hannifen compression fittings at the FFTF have been examined and evaluated to determine the metallurgical condition as related to carbide precipitation in grain boundaries (known as sensitization) and the implications this may have with regard to corrosion resistance. To accomplish this, two ferrules from new stock, two ferrules from old stock and two ferrules that had seen service were examined metallurgically. The samples were prepared for optical metallography. They were viewed in both the etched and unetched condition and analyzed on the scanning electron microscope (SEM) for elemental content. It was confirmed that the ferrules from new stock had a 5 mil thick nitrided layer on the ferrule ID at the lead end and that the 316 SS ferrule material was in the sensitized condition, indicating low resistance to aqueous corrosion. The material from old stock had no nitride layer but was in the sensitized condition indicating low resistance to aqueous corrosion. The ferrules that had seen service had not been nitrided and were not sensitized indicating high resistance to aqueous corrosion

  18. Radiation-sensitive diacrylates

    International Nuclear Information System (INIS)

    Demajistre, R.

    1976-01-01

    Novel diacrylates are prepared by reacting a monohydroxylated acrylic monomer with a polyisocyanate. The reaction product may be polymerized by subjecting to ionizing irradiation, actinic light or to free radical catalysts to form a useful coating material. The diacrylates may also be copolymerized with other radiation sensitive materials. 6 claims, no drawings

  19. Multiple Chemical Sensitivity

    DEFF Research Database (Denmark)

    Junge, Anne Gram

    Et voksende antal mennesker i Danmark oplever at være overfølsomme over for dufte og kemikalier. Imidlertid er den tilskrevne diagnose Multiple Chemical Sensitivity (MCS) ikke medicinsk anerkendt i Danmark pga. mangel på organiske og patofysiologisk basis for symptomerne. Dette speciale bygger på...

  20. Biomass Compositional Analysis Laboratory Procedures | Bioenergy | NREL

    Science.gov (United States)

    Biomass Compositional Analysis Laboratory Procedures Biomass Compositional Analysis Laboratory Procedures NREL develops laboratory analytical procedures (LAPs) for standard biomass analysis. These procedures help scientists and analysts understand more about the chemical composition of raw biomass

  1. Influence of mixing procedure on robustness of self-consolidating concrete.

    Science.gov (United States)

    2014-08-01

    Self-Consolidating Concrete is, in the fresh state, more sensitive to small variations in the constituent elements and the mixing : procedure compared to Conventional Vibrated Concrete. Several studies have been performed recently to identify robustn...

  2. Simplified Laboratory Runoff Procedure (SLRP): Procedure and Application

    National Research Council Canada - National Science Library

    Price, Richard

    2000-01-01

    The Simplified Laboratory Runoff Procedure (SLRP) was developed to provide a faster, less expensive approach to evaluate surface runoff water quality from dredged material placed in an upland environment...

  3. Pelvic denervation procedures for dysmenorrhea.

    Science.gov (United States)

    Ramirez, Christina; Donnellan, Nicole

    2017-08-01

    Chronic pelvic pain and dysmenorrhea are common conditions affecting reproductive-age women. Surgical pelvic denervation procedures may be a treatment option for women with midline dysmenorrhea, in which medical management is declined by the patient, ineffective at managing symptoms, or medically contraindicated. This review describes the surgical techniques and complications associated with pelvic denervation procedures as well as the current evidence for these procedures in women with primary dysmenorrhea and dysmenorrhea secondary to endometriosis. Presacral neurectomy is the preferred pelvic denervation procedure in patients with primary dysmenorrhea and midline chronic pelvic pain associated with endometriosis. In patients with endometriosis presacral neurectomy is a useful adjunct to excision or ablation of all endometrial lesions to improve postoperative pain relief. There is no additional patient benefit of performing combined presacral neurectomy and uterine nerve ablation procedures. Pelvic denervation procedures can be performed safely and quickly with a low risk of complication if the surgeon is knowledgeable and skilled in operating in the presacral space. Patients should be adequately counseled on expected success rates and potential complications associated with pelvic denervation procedures.

  4. Specified assurance level sampling procedure

    International Nuclear Information System (INIS)

    Willner, O.

    1980-11-01

    In the nuclear industry design specifications for certain quality characteristics require that the final product be inspected by a sampling plan which can demonstrate product conformance to stated assurance levels. The Specified Assurance Level (SAL) Sampling Procedure has been developed to permit the direct selection of attribute sampling plans which can meet commonly used assurance levels. The SAL procedure contains sampling plans which yield the minimum sample size at stated assurance levels. The SAL procedure also provides sampling plans with acceptance numbers ranging from 0 to 10, thus, making available to the user a wide choice of plans all designed to comply with a stated assurance level

  5. Rehydrating dye sensitized solar cells

    Directory of Open Access Journals (Sweden)

    Christian Hellert

    2017-05-01

    Full Text Available Dye sensitized solar cells (DSSCs are silicon free, simply producible solar cells. Longevity, however, is a longstanding problem for DSSCs. Due to liquid electrolytes being commonly used, evaporation of the electrolyte causes a dramatic drop in electric output as cells continue to be used unmaintained. Stopping evaporation has been tried in different ways in the past, albeit with differing degrees of success. In a recent project, a different route was chosen, exploring ways of revitalizing DSSCs after varying periods of usage. For this, we focused on rehydration of the cells using distilled water as well as the electrolyte contained in the cells. The results show a significant influence of these rehydration procedures on the solar cell efficiency. In possible applications of DSSCs in tents etc., morning dew may thus be used for rehydration of solar cells. Refillable DSSCs can also be used in tropical climates or specific types of farms and greenhouses where high humidity serves the purpose of rehydrating DSSCs.

  6. Application of differential sensitivity theory to transients with scram

    International Nuclear Information System (INIS)

    Parks, C.V.; Maudlin, P.J.; Weber, C.F.

    1980-01-01

    Differential sensitivity theory (DST) based on adjoint functions has been applied to various reactor safety problems. The most comprehensive application of DST sensitivity analysis has addressed the coupled thermal-hydraulic equations of the MELT-III fast reactor safety code, where a power ramp was imposed to eliminate the neutron point kinetics equations. In extending the above work to include realistic neutronic coupling, a DST procedure was developed for dealing with parameter discontinuities induced by dependent variables

  7. ANAESTHESIA FOR OPHTHALMIC SURGICAL PROCEDURES

    African Journals Online (AJOL)

    Objective: To review factors influencing the choice of anaesthesia for ophthalmic surgical procedures. ... as risk associated with general anaesthesia (8) they are more .... Wilson ME, Pandey SK, Thakur J. Paediatric cataract blindness in the ...

  8. Adequate procedures for specific exams

    International Nuclear Information System (INIS)

    Staevie, G.L.G.; Gattringer, D.K.; Dal Mas, C.R.; Tessman, M.

    1996-01-01

    Some ideal procedures for specific radiographic exams are briefly presented. The aim is to improve the quality standard, establishing a specific method for each exam in order to decrease films waste and reduce the patient dose exposure

  9. Soil Gas Sampling Operating Procedure

    Science.gov (United States)

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil gas samples for field screening or laboratory analysis.

  10. Construction inspection manual of procedures

    Science.gov (United States)

    2009-01-01

    This manual provides highway construction personnel with relevant, practical information in order to perform accurate inspections and provide relevant construction procedural information for the various roadway and structures items of work. It is the...

  11. Fusion Imaging for Procedural Guidance.

    Science.gov (United States)

    Wiley, Brandon M; Eleid, Mackram F; Thaden, Jeremy J

    2018-05-01

    The field of percutaneous structural heart interventions has grown tremendously in recent years. This growth has fueled the development of new imaging protocols and technologies in parallel to help facilitate these minimally-invasive procedures. Fusion imaging is an exciting new technology that combines the strength of 2 imaging modalities and has the potential to improve procedural planning and the safety of many commonly performed transcatheter procedures. In this review we discuss the basic concepts of fusion imaging along with the relative strengths and weaknesses of static vs dynamic fusion imaging modalities. This review will focus primarily on echocardiographic-fluoroscopic fusion imaging and its application in commonly performed transcatheter structural heart procedures. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, RW; Dirkes, RL

    1990-02-01

    This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.

  13. FFTF reactor plant procedures plan

    International Nuclear Information System (INIS)

    1972-01-01

    The document presented defines the plan to be used to coordinate the preparation, review, approval, and issuance of the operating procedure documents required to ensure safe and efficient operation of FFTF

  14. Adolescent test or procedure preparation

    Science.gov (United States)

    ... someone else) during the procedure Playing hand-held video games Using guided imagery Trying other distractions, such as ... effects the test may cause. Older teens may benefit from videos that show adolescents of the same age explaining ...

  15. Environmental protection and procedural law

    International Nuclear Information System (INIS)

    Mutschler, U.

    1978-01-01

    For the power industry which is 'independent of licensing', the Ule/Laubinger statement as well as its discussion on the 52th German legal experts' day are of considerable importance. It is therefore absolutely necessary to critically investigate the statements of this expert's opinion and the considerations on which they are based. This investigation is limited to those licensing procedures which in the terminology of experts, are 'similar to the plan approval procedure'. This applies mainly to the procedures according to paragraph 4 ff of the Federal Act on the Protection Against Nuisances and paragraph 7 of the Atomic Energy Law: Preliminaries publication of documents, inspection of files, public hearing, taking of evidence, persons with special responsibilities, administrative proceedings, actions by associations. The deficiencies in the execution of environmental procedural law is briefly mentioned. The notes in the article refer only to air pollution. (orig./HP) [de

  16. Urinary incontinence - vaginal sling procedures

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007376.htm Urinary incontinence - vaginal sling procedures To use the sharing features ... are types of surgeries that help control stress urinary incontinence . This is urine leakage that happens when you ...

  17. Loop Electrosurgical Excision Procedure (LEEP)

    Science.gov (United States)

    ... applied to your cervix to stop any bleeding. Electrocautery also may be used to control bleeding. The ... the uterus at the top of the vagina. Electrocautery: A procedure in which an instrument works with ...

  18. Process & Quality procedures for transport & handling activities

    CERN Document Server

    Böttcher, O

    2002-01-01

    To respect the detailed and complex planning of the LHC installation project it is essential to reduce possible faults in every technical service that can cause delays in the schedule. In order to ensure proper execution of transport and handling activities it is important to get detailed information from the clients as early as possible in order to do the planning and the organisation of the required resources. One procedure that requires greater focus in the future is the preparation of the resources. The goal is to prevent equipment breakdowns and accidents while executing transport and handling activities. In the LEP dismantling project multiple breakdowns of important cranes caused serious problems in the project schedule. For the LHC installation project similar incidents in the reliability of the equipment cannot be accepted because of the high sensitivity of the whole schedule. This paper shall outline the efforts and methods that are put in place in order to meet the LHC installation requirements.

  19. PAYMENT CAPACITY SENSITIVITY FACTORS

    OpenAIRE

    Daniel BRÎNDESCU – OLARIU

    2014-01-01

    The current study focuses on the sensitivity of the corporate payment capacity. Through the nature of the subject, the research is based on simulating variations of the forecasted cash-flows of the companies included in the sample. The study employs 391 forecasted yearly cash-flows statements collected from 50 companies from Timis County (Romania), as well as the detailed hypotheses of the forecasts. The results of the study facilitate the determination and classification of the main se...

  20. Mutagenic sensitivity to triticales

    International Nuclear Information System (INIS)

    Reddy, V.R.K.

    1993-01-01

    The effect of gamma rays, ethyl methane sulphonate and their combined treatments on germination, survival, seedling height and sterility were studied in one winter Triticale var. 6TA 87 and one sprig Triticale var. cinnamon. Based on LD 50 , degree of reduction in seedling height and increase in seed and pollen sterility, it was concluded that Triticale var. cinnamon is highly sensitive and mutable compared to Triticale 6TA 876. (author). 5 refs., 2 tabs

  1. Interference and Sensitivity Analysis.

    Science.gov (United States)

    VanderWeele, Tyler J; Tchetgen Tchetgen, Eric J; Halloran, M Elizabeth

    2014-11-01

    Causal inference with interference is a rapidly growing area. The literature has begun to relax the "no-interference" assumption that the treatment received by one individual does not affect the outcomes of other individuals. In this paper we briefly review the literature on causal inference in the presence of interference when treatments have been randomized. We then consider settings in which causal effects in the presence of interference are not identified, either because randomization alone does not suffice for identification, or because treatment is not randomized and there may be unmeasured confounders of the treatment-outcome relationship. We develop sensitivity analysis techniques for these settings. We describe several sensitivity analysis techniques for the infectiousness effect which, in a vaccine trial, captures the effect of the vaccine of one person on protecting a second person from infection even if the first is infected. We also develop two sensitivity analysis techniques for causal effects in the presence of unmeasured confounding which generalize analogous techniques when interference is absent. These two techniques for unmeasured confounding are compared and contrasted.

  2. Tactual sensitivity in hypochondriasis.

    Science.gov (United States)

    Haenen, M A; Schmidi, A J; Schoenmakers, M; van den Hout, M A

    1997-01-01

    In his article on amplification, somatization and somatoform disorders Barsky [Psychosomatics 1992; 33:28-34] pointed out the importance of studying the perception and processing of somatic and visceral symptoms. Subsequently, it was demonstrated that hypochondriacal patients are not more accurately aware of cardiac activity than a group of non-hypochondriacal patients. Authors concluded that hypochondriacal somatic complaints do not result from an unusually fine discriminative ability to detect normal physiological sensations that non-hypochondriacal patients are unable to perceive. The aim of the present study was to investigate tactual sensitivity to non-painful stimuli in hypochondriacal patients and healthy subjects. Twenty-seven outpatients with DSM-III-R hypochondriasis and 27 healthy control subjects were compared. In all subjects the two-point discrimination threshold was measured, as well as subjective sensitivity to harmless bodily sensations as measured by the Somatosensory Amplification Scale. It was found that hypochondriacal patients reported more distress and discomfort with benign bodily sensations. The two-point discrimination threshold of hypochondriacal patients was not significantly lower in patients as compared to controls. Hypochondriacal subjects considered themselves more sensitive to benign bodily sensations without being better able to discriminate between two tactual bodily signals. These findings of the present study correspond quite closely to those reported earlier.

  3. Safety analysis procedures for PHWR

    International Nuclear Information System (INIS)

    Min, Byung Joo; Kim, Hyoung Tae; Yoo, Kun Joong

    2004-03-01

    The methodology of safety analyses for CANDU reactors in Canada, a vendor country, uses a combination of best-estimate physical models and conservative input parameters so as to minimize the uncertainty of the plant behavior predictions. As using the conservative input parameters, the results of the safety analyses are assured the regulatory requirements such as the public dose, the integrity of fuel and fuel channel, the integrity of containment and reactor structures, etc. However, there is not the comprehensive and systematic procedures for safety analyses for CANDU reactors in Korea. In this regard, the development of the safety analyses procedures for CANDU reactors is being conducted not only to establish the safety analyses system, but also to enhance the quality assurance of the safety assessment. In the first phase of this study, the general procedures of the deterministic safety analyses are developed. The general safety procedures are covered the specification of the initial event, selection of the methodology and accident sequences, computer codes, safety analysis procedures, verification of errors and uncertainties, etc. Finally, These general procedures of the safety analyses are applied to the Large Break Loss Of Coolant Accident (LBLOCA) in Final Safety Analysis Report (FSAR) for Wolsong units 2, 3, 4

  4. Collected radiochemical and geochemical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kleinberg, J [comp.

    1990-05-01

    This revision of LA-1721, 4th Ed., Collected Radiochemical Procedures, reflects the activities of two groups in the Isotope and Nuclear Chemistry Division of the Los Alamos National Laboratory: INC-11, Nuclear and radiochemistry; and INC-7, Isotope Geochemistry. The procedures fall into five categories: I. Separation of Radionuclides from Uranium, Fission-Product Solutions, and Nuclear Debris; II. Separation of Products from Irradiated Targets; III. Preparation of Samples for Mass Spectrometric Analysis; IV. Dissolution Procedures; and V. Geochemical Procedures. With one exception, the first category of procedures is ordered by the positions of the elements in the Periodic Table, with separate parts on the Representative Elements (the A groups); the d-Transition Elements (the B groups and the Transition Triads); and the Lanthanides (Rare Earths) and Actinides (the 4f- and 5f-Transition Elements). The members of Group IIIB-- scandium, yttrium, and lanthanum--are included with the lanthanides, elements they resemble closely in chemistry and with which they occur in nature. The procedures dealing with the isolation of products from irradiated targets are arranged by target element.

  5. Subset simulation for structural reliability sensitivity analysis

    International Nuclear Information System (INIS)

    Song Shufang; Lu Zhenzhou; Qiao Hongwei

    2009-01-01

    Based on two procedures for efficiently generating conditional samples, i.e. Markov chain Monte Carlo (MCMC) simulation and importance sampling (IS), two reliability sensitivity (RS) algorithms are presented. On the basis of reliability analysis of Subset simulation (Subsim), the RS of the failure probability with respect to the distribution parameter of the basic variable is transformed as a set of RS of conditional failure probabilities with respect to the distribution parameter of the basic variable. By use of the conditional samples generated by MCMC simulation and IS, procedures are established to estimate the RS of the conditional failure probabilities. The formulae of the RS estimator, its variance and its coefficient of variation are derived in detail. The results of the illustrations show high efficiency and high precision of the presented algorithms, and it is suitable for highly nonlinear limit state equation and structural system with single and multiple failure modes

  6. The Social Psychology of Gender Differences and Procedural Justice in Close Relationships

    NARCIS (Netherlands)

    Tumewu, M.

    2007-01-01

    In this dissertation the influence of procedural justice on the reactions of men and women in contexts related to close relationships. Women are thought to be more sensitive to procedural justice than men because women are more caring towards others and value their close relationships more than men.

  7. Measuring variability of procedure progression in proceduralized scenarios

    International Nuclear Information System (INIS)

    Kim, Yochan; Park, Jinkyun; Jung, Wondea

    2012-01-01

    Highlights: ► The VPP measure was developed to quantify how differently operators follow the procedures. ► Sources that cause variability of ways to follow a given procedure were identified. ► The VPP values for the scenarios are positively related to the scenario performance time. ► The VPP measure is meaningful for explaining characteristics of several PSFs. -- Abstract: Various performance shaping factors (PSFs) have been presented to explain the contributors to unsafe acts in a human failure event or predict a human error probability of new human performance. However, because most of these parameters of an HRA depend on the subjective knowledge and experience of HRA analyzers, the results of an HRA insufficiently provide unbiased standards to explain human performance variations or compare collected data with other data from different analyzers. To secure the validity of the HRA results, we propose a quantitative measure, which represents the variability of procedure progression (VPP) in proceduralized scenarios. A VPP measure shows how differently the operators follow the steps of the procedures. This paper introduces the sources of the VPP measure and relevance to PSFs. The assessment method of the VPP measure is also proposed, and the application examples are shown with a comparison of the performance time. Although more empirical studies should be conducted to reveal the relationship between the VPP measure and other PSFs, it is believed that the VPP measure provides evidence to quantitatively evaluate human performance variations and to cross-culturally compare the collected data.

  8. The influence of different measurement structures on NRTA test procedures

    International Nuclear Information System (INIS)

    Beedgen, R.

    1986-01-01

    The development of sequential statistical test procedures in the area of near real time material accountancy (NRTA) mostly assumed a fixed measurement model of a given model facility. In this paper different measurement models (dispersion matrices) for a sequence of balance periods are studied. They are used to compare the detection probabilities of three different sequential test procedures for losses of material. It is shown how different plant models have an influence on the sensitivity of specified tests. Great importance for that analysis have the optimal loss patterns in each measurement situation

  9. Kinematic sensitivity of robot manipulators

    Science.gov (United States)

    Vuskovic, Marko I.

    1989-01-01

    Kinematic sensitivity vectors and matrices for open-loop, n degrees-of-freedom manipulators are derived. First-order sensitivity vectors are defined as partial derivatives of the manipulator's position and orientation with respect to its geometrical parameters. The four-parameter kinematic model is considered, as well as the five-parameter model in case of nominally parallel joint axes. Sensitivity vectors are expressed in terms of coordinate axes of manipulator frames. Second-order sensitivity vectors, the partial derivatives of first-order sensitivity vectors, are also considered. It is shown that second-order sensitivity vectors can be expressed as vector products of the first-order sensitivity vectors.

  10. Sensitizing pigment in the fly

    International Nuclear Information System (INIS)

    Vogt, K.; Kirschfeld, K.

    1983-01-01

    The sensitizing pigment hypothesis for the high UV sensitivity in fly photoreceptors (R1-6) is further substantiated by measurements of the polarisation sensitivity in the UV. The quantum yield of the energy transfer from sensitizing pigment to rhodopsin was estimated by electrophysiological measurements of the UV sensitivity and the rhabdomeric absorptance (at 490 nm) in individual receptor cells. The transfer efficiency is >=0.75 in receptors with an absorptance in the rhabdomeres of 0.55-0.95. This result suggests that the sensitizing pigment is bound in some way to the rhodopsin. A ratio of two molecules of sensitizing pigment per one rhodopsin is proposed. (orig.)

  11. Phase sensitive multichannel OCT

    International Nuclear Information System (INIS)

    Trasischker, W.

    2015-01-01

    The main aim of this thesis was to develop and improve phase sensitive, multichannel methods for optical coherence tomography (OCT) using light in the 840 nm and 1040 nm regime. Conventional OCT provides purely structural information by illuminating the sample by one beam and recording the backscattered signal with one detection channel. Combination of this approach with a raster scan enables the acquisition of 2D and 3D structural information with a resolution in the micrometer regime. However, sometimes additional image contrast or information is desired. Amongst other approaches, this can be provided by a phase sensitive analysis of the interference pattern. Combining phase sensitivity with the illumination of the sample by more than one beam and/or by recording the data using more than one data acquisition channel allows for even more enhanced imaging. While phase sensitive OCT gives access to additional contrast and information, multichannel OCT can provide higher imaging speed, scan eld size and exible dierential measurements. Amongst the dierential, phase sensitive approaches, Doppler OCT (DOCT) and polarization sensitive OCT (PS-OCT) are two of the most promising OCT modalities. While the former targets information on the movement of backscattering particles, the latter measures alterations of the polarization state of the light induced by the sample. Both techniques provide additional image contrast and are, due to the non-invasive and fast character of OCT, well suited for in vivo imaging of the human eye. In the course of this thesis, two dierent multichannel, phase sensitive OCT systems will be presented. First, a D-OCT system with three dierent sampling beams is described. With a central wavelength of 840 nm these three beams are emitted by three individual laser sources. This eectively eliminates any cross talk and provides the full depth range for each channel. Furthermore, by illuminating the sample from three dierent directions, the absolute

  12. Renal diagnostic nuclear medicine procedures in progressive systemic scleroderma (PSS)

    Energy Technology Data Exchange (ETDEWEB)

    Ammari, B.; Hotze, A.; Gruenwald, F.; Biersack, H.J.; Blitz, H.; Kuester, W.; Kreysel, H.W.

    1989-02-01

    The involvement of kidneys in progressive systemic scleroderma (PSS) is one of the most frequent causes of death in this disease. Using clinical criteria and laboratory tests only the frequency of kidney involvement would be clearly underestimated. Invasive diagnostic procedures such as biopsy and angiography can not be applied in those patients. Nuclear medicine techniques (hippurate clearance, DMSA-scan), however, offer non invasive and sensitive methods in the diagnosis of renal involvement in PSS patients. In our study 46 of 76 patients (60%) revealed pathologic findings. The mentioned diagnostic techniques show a high sensitivity and are in agreement with pathological findings described in PSS.

  13. Renal diagnostic nuclear medicine procedures in progressive systemic scleroderma (PSS)

    International Nuclear Information System (INIS)

    Ammari, B.; Hotze, A.; Gruenwald, F.; Biersack, H.J.; Blitz, H.; Kuester, W.; Kreysel, H.W.

    1989-01-01

    The involvement of kidneys in progressive systemic scleroderma (PSS) is one of the most frequent causes of death in this disease. Using clinical criteria and laboratory tests only the frequency of kidney involvement would be clearly underestimated. Invasive diagnostic procedures such as biopsy and angiography can not be applied in those patients. Nuclear medicine techniques (hippurate clearance, DMSA-scan), however, offer non invasive and sensitive methods in the diagnosis of renal involvement in PSS patients. In our study 46 of 76 patients (60%) revealed pathologic findings. The mentioned diagnostic techniques show a high sensitivity and are in agreement with pathological findings described in PSS. (orig.) [de

  14. Deterministic Local Sensitivity Analysis of Augmented Systems - I: Theory

    International Nuclear Information System (INIS)

    Cacuci, Dan G.; Ionescu-Bujor, Mihaela

    2005-01-01

    This work provides the theoretical foundation for the modular implementation of the Adjoint Sensitivity Analysis Procedure (ASAP) for large-scale simulation systems. The implementation of the ASAP commences with a selected code module and then proceeds by augmenting the size of the adjoint sensitivity system, module by module, until the entire system is completed. Notably, the adjoint sensitivity system for the augmented system can often be solved by using the same numerical methods used for solving the original, nonaugmented adjoint system, particularly when the matrix representation of the adjoint operator for the augmented system can be inverted by partitioning

  15. Program Baseline Change Control Procedure

    International Nuclear Information System (INIS)

    1993-02-01

    This procedure establishes the responsibilities and process for approving initial issues of and changes to the technical, cost, and schedule baselines, and selected management documents developed by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System. This procedure implements the OCRWM Baseline Management Plan and DOE Order 4700.1, Chg 1. It streamlines the change control process to enhance integration, accountability, and traceability of Level 0 and Level I decisions through standardized Baseline Change Proposal (BCP) forms to be used by the Level 0, 1, 2, and 3 Baseline Change Control Boards (BCCBs) and to be tracked in the OCRWM-wide Configuration Information System (CIS) Database.This procedure applies to all technical, cost, and schedule baselines controlled by the Energy System Acquisition Advisory Board (ESAAB) BCCB (Level 0) and, OCRWM Program Baseline Control Board (PBCCB) (Level 1). All baseline BCPs initiated by Level 2 or lower BCCBs, which require approval from ESAAB or PBCCB, shall be processed in accordance with this procedure. This procedure also applies to all Program-level management documents controlled by the OCRWM PBCCB

  16. Designing Flightdeck Procedures: Literature Resources

    Science.gov (United States)

    Feldman, Jolene; Barshi, Immanuel; Degani, Asaf; Loukopoulou, Loukia; Mauro, Robert

    2017-01-01

    This technical publication contains the titles, abstracts, summaries, descriptions, and/or annotations of available literature sources on procedure design and development, requirements, and guidance. It is designed to provide users with an easy access to available resources on the topic of procedure design, and with a sense of the contents of these sources. This repository of information is organized into the following publication sources: Research (e.g., journal articles, conference proceedings), Manufacturers' (e.g., operation manuals, newsletters), and Regulatory and/or Government (e.g., advisory circulars, reports). An additional section contains synopses of Accident/Incident Reports involving procedures. This work directly supports a comprehensive memorandum by Barshi, Mauro, Degani, & Loukopoulou (2016) that summarizes the results of a multi-year project, partially funded by the FAA, to develop technical reference materials that support guidance on the process of developing cockpit procedures (see "Designing Flightdeck Procedures" https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/20160013263.pdf). An extensive treatment of this topic is presented in a forthcoming book by the same authors.

  17. Context Sensitive Health Informatics

    DEFF Research Database (Denmark)

    Kuziemsky, Craig; Nøhr, Christian; Aarts, Jos

    2013-01-01

    Context is a key consideration when designing and evaluating health information technology (HIT) and cannot be overstated. Unintended consequences are common post HIT implementation and even well designed technology may not achieve desired outcomes because of contextual issues. While context should...... be considered in the design and evaluation of health information systems (HISs) there is a shortcoming of empirical research on contextual aspects of HIT. This conference integrates the sociotechnical and Human-Centered-Design (HCD) approaches and showcases current research on context sensitive health...... informatics. The papers and presentations outlines theories and models for studying contextual issues and insights on how we can better design HIT to accommodate different healthcare contexts....

  18. Dye Sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    Di Wei

    2010-03-01

    Full Text Available Dye sensitized solar cell (DSSC is the only solar cell that can offer both the flexibility and transparency. Its efficiency is comparable to amorphous silicon solar cells but with a much lower cost. This review not only covers the fundamentals of DSSC but also the related cutting-edge research and its development for industrial applications. Most recent research topics on DSSC, for example, applications of nanostructured TiO2, ZnO electrodes, ionic liquid electrolytes, carbon nanotubes, graphene and solid state DSSC have all been included and discussed.

  19. Multiple Chemical Sensitivity

    DEFF Research Database (Denmark)

    Dantoft, Thomas Meinertz

    Multiple chemical sensitivity (MCS) is a chronic disorder characterized by reports of symptoms from various organ systems attributed by the individuals to exposure to common odors and airborne chemicals in doses far below those known to induce toxic effects. There exists a general lack of knowledge......, significantly reduced levels of IL-13 in the MCS group and no group differences in the allergen specific IgE measures. The differences were independent of factors such as sex, age, Body Mass Index, asthma, smoking, depression, anxiety and allergen-specific IgE. In conclusion, the study identified a distinct...

  20. Breastfeeding and its relation to maternal sensitivity and infant attachment.

    Science.gov (United States)

    Tharner, Anne; Luijk, Maartje P C M; Raat, Hein; Ijzendoorn, Marinus H; Bakermans-Kranenburg, Marian J; Moll, Henriette A; Jaddoe, Vincent W V; Hofman, Albert; Verhulst, Frank C; Tiemeier, Henning

    2012-06-01

    To examine the association of breastfeeding with maternal sensitive responsiveness and infant-mother attachment security and disorganization. We included 675 participants of a prospective cohort study. Questionnaires about breastfeeding practices were administered at 2 and 6 months postpartum. At 14 months, maternal sensitive responsiveness was assessed in a 13-minute laboratory procedure using Ainsworth's sensitivity scales, and attachment quality was assessed with the Strange Situation Procedure. Mothers were genotyped for oxytocin receptor genes OXTR rs53576 and OXTR rs2254298. Linear regressions and analyses of covariance adjusted for various background variables were conducted. We tested for mediation and moderation by maternal sensitive responsiveness and maternal oxytocin receptor genotype. Continuous analyses showed that longer duration of breastfeeding was associated with more maternal sensitive responsiveness (B = 0.11, 95% confidence interval [CI] 0.02; 0.20, p attachment security (B = 0.24, 95% CI = 0.02; 0.46, p attachment disorganization (B = -0.20, 95% CI -0.36; -0.03, p attachment classification, but longer duration of breastfeeding predicted a lower risk of disorganized versus secure attachment classification (n = 151; odds ratio [OR] = 0.81, 95% CI 0.66 to 0.99, p = .04). Maternal sensitive responsiveness did not mediate the associations, and maternal oxytocin receptor genotype was not a significant moderator. Although duration of breastfeeding was not associated with differences in infant-mother attachment classifications, we found subtle positive associations between duration of breastfeeding and sensitive responsiveness, attachment security, and disorganization.

  1. New procedure for departure formalities

    CERN Multimedia

    HR & GS Departments

    2011-01-01

    As part of the process of simplifying procedures and rationalising administrative processes, the HR and GS Departments have introduced new personalised departure formalities on EDH. These new formalities have applied to students leaving CERN since last year and from 17 October 2011 this procedure will be extended to the following categories of CERN personnel: Staff members, Fellows and Associates. It is planned to extend this electronic procedure to the users in due course. What purpose do departure formalities serve? The departure formalities are designed to ensure that members of the personnel contact all the relevant services in order to return any necessary items (equipment, cards, keys, dosimeter, electronic equipment, books, etc.) and are aware of all the benefits to which they are entitled on termination of their contract. The new departure formalities on EDH have the advantage of tailoring the list of services that each member of the personnel must visit to suit his individual contractual and p...

  2. Design Procedure for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Tjelflaat, Per Olaf

    Mechanical and natural ventilation systems have developed separately during many years. The natural next step in this development is development of ventilation concepts that utilises and combines the best features from each system into a new type of ventilation system - Hybrid Ventilation....... Buildings with hybrid ventilation often include other sustainable technologies and an energy optimisation requires an integrated approach in the design of the building and its mechanical systems. Therefore, the hybrid ventilation design procedure differs from the design procedure for conventional HVAC....... The first ideas on a design procedure for hybrid ventilation is presented and the different types of design methods, that is needed in different phases of the design process, is discussed....

  3. Acute Procedural Pain in Children

    DEFF Research Database (Denmark)

    Kristensen, Helle Nygård; Lundbye-Christensen, Søren; Haslund-Thomsen, Helle

    2018-01-01

    INTRODUCTION: Hospitalized children often describe needle-related procedures as the worst pain possible and such procedures may be emotionally traumatic. The use of hospital clowns related to painful medical procedures in children may offer pain relief, but this has not been systematically...... evaluated. The objective of this study was to assess the effect of a therapeutic clown in comparison to standard care on the experience of pain for children receiving venipuncture. METHODS: A sample of 116 children aged 4-15 years consecutively admitted to the hospital was allocated to either......: Without the clown present, the mean pain score (2.7±2.8) was not significantly different between the two age groups. Children aged 7-15 years had lower pain scores when the clown was present compared to the control group (P=0.025). Children aged 4-6 years had higher pain scores with the clown present...

  4. MITG test procedure and results

    International Nuclear Information System (INIS)

    Eck, M.E.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  5. Radiation control standards and procedures

    Energy Technology Data Exchange (ETDEWEB)

    1956-12-14

    This manual contains the Radiation Control Standards'' and Radiation Control Procedures'' at Hanford Operations which have been established to provide the necessary control radiation exposures within Irradiation Processing Department. Provision is also made for including, in the form of Bulletins'', other radiological information of general interest to IPD personnel. The purpose of the standards is to establish firm radiological limits within which the Irradiation Processing Department will operate, and to outline our radiation control program in sufficient detail to insure uniform and consistent application throughout all IPD facilities. Radiation Control Procedures are intended to prescribe the best method of accomplishing an objective within the limitations of the Radiation Control Standards. A procedure may be changed at any time provided the suggested changes is generally agreeable to management involved, and is consistent with department policies and the Radiation Control Standards.

  6. MR diagnostics after Ross procedure

    International Nuclear Information System (INIS)

    Steffens, J.C.; Link, J.; Harringer, W.; Haverich, A.; Heller, M.

    1996-01-01

    Purpose: To determine the ability of MRI to diagnose morphological and functional changes in patients after Ross procedure. Material and methods: During one year, 5 patients after Ross procedure were studied by MRI. T 1 -weighted spin-echo sequences in different orientations as well as cine sequences and a VENC-sequence were used. Results: In all patients the morphology including the postoperative changes could be visualised by MRI. The cine sequences provided functional information on valvular and ventricular function. VENC-MR yielded an exact quantification of the regurgitant fraction. Conclusion: MRI is capable of providing all important diagnostic information in patients after Ross procedure such as valvular and ventricular function and valvular and outflow tract morphology in a single examination. (orig.) [de

  7. Transversal of Procedure Elements in a Computerized Procedure System

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yeonsub [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    APR1400 MCR(Main Control Room) has introduced CPS(Computerized Procedure System). APR400 CPS is framed with overview pane, step detail pane, and monitoring pane. The overview shows the step in one dimensional array. Diagram in the step detail pane is called as flowlogic diagram. The flowlogic diagram has advantage of being intuitive and not being segmented so that the interfaces are easy to follow and understand. While developing CPS software or training operators these interfaces, however, there is still areas to refine behaviors of flowlogic diagram. If flowlogic diagram has contingency instructions, it is sometime difficult to interpret it properly. Therefore this paper is trying to explain behavior of flowlogic diagram in view of procedure elements. Procedure execution can be called as transversal of steps and instructions in flowlogic diagram. Both hierarchy of procedures elements and flowlogic diagram provides useful framework to test transversal with completeness. Navigation button behaviors are interpreted in view of flowlogic diagram. The framework and flowlogic diagram can be further applied to improve CPS user interfaces.

  8. [Sensitization to Lyral].

    Science.gov (United States)

    Heras, F; Díaz-Recuero, J L; Cabello, M J; Conde-Salazar, L

    2006-01-01

    Lyral is a fragrance that is present in many cosmetic products. It has turned into an emergent allergen during the last years. In studies carried out in other European countries, the prevalence of sensitization to Lyral has been found to be 1.9-2.7 %, but it is unknown the prevalence in Spain, as well as the need to include it or not in the standard series of the Spanish Group of Contact Dermatitis (GEIDC). We have patch-tested to Lyral all patients with suspicion of contact dermatitis of any origin who attended our Service between April and May-2005. From a total of 170 patients included in our study, 2 of them had a sensitization to Lyral (1.2 %). One of these two patients had an axillae contact dermatitis caused by a deodorant containing Lyral. The other patient was a masseur-woman with a contact dermatitis on both hands, with periods of dissemination to upper extremities and trunk, and who used several cosmetics products for private reasons and during her job. Although the sample of this study is quite small, we think that the results allow to suspect that Lyral is one of the main allergens, or even the most important, in causing allergic contact dermatitis to fragrances in our environment. Therefore, we believe that we must raise the inclusion of Lyral in the standard series of GEIDC, either as independent allergen, or including it in a new mixture of fragrances.

  9. Sensitive high performance liquid chromatographic method for the ...

    African Journals Online (AJOL)

    A new simple, sensitive, cost-effective and reproducible high performance liquid chromatographic (HPLC) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 4-chlorophenylbiguanide (4-CPB) in urine and plasma is described. The extraction procedure is a simple three-step process ...

  10. the sensitivity of a syndromic management approach in detecting ...

    African Journals Online (AJOL)

    MANAGEMENT APPROACH IN. DETECTING SEXUALLY. TRANSMITTED DISEASES IN. PATIENTS AT A PUBLIC HEALTH. CLINIC IN CAPE TOWN. C Mathews, A van Rensburg, N Coetzee. Objectives. To evaluate the sensitivity of a syndromic diagnostic procedure in detecting and treating sexually transmitted diseases ...

  11. Technique for Measuring Speed and Visual Motion Sensitivity in Lizards

    Science.gov (United States)

    Woo, Kevin L.; Burke, Darren

    2008-01-01

    Testing sensory characteristics on herpetological species has been difficult due to a range of properties related to physiology, responsiveness, performance ability, and the type of reinforcer used. Using the Jacky lizard as a model, we outline a successfully established procedure in which to test the visual sensitivity to motion characteristics.…

  12. Sensitivity and specificity of coherence and phase synchronization analysis

    International Nuclear Information System (INIS)

    Winterhalder, Matthias; Schelter, Bjoern; Kurths, Juergen; Schulze-Bonhage, Andreas; Timmer, Jens

    2006-01-01

    In this Letter, we show that coherence and phase synchronization analysis are sensitive but not specific in detecting the correct class of underlying dynamics. We propose procedures to increase specificity and demonstrate the power of the approach by application to paradigmatic dynamic model systems

  13. Procedures monitoring and MAAP analysis

    International Nuclear Information System (INIS)

    May, R.S.

    1991-01-01

    Numerous studies of severe accidents in light water reactors have shown that operator response can play a crucial role in the predicted outcomes of dominant accident scenarios. MAAP provides the capability to specify certain operator actions as input data. However, making reasonable assumptions about the nature and timing of operator response requires substantial knowledge about plant practices and procedures and what they imply for the event being analyzed. The appearance of knowledge based software technology in the mid-1980s provided a natural format for representing and maintaining procedures as IF-THEN rules. The boiling water reactor (BWR) Emergency Operating Procedures Tracking System (EOPTS) was composed of a rule base of procedures and a dedicated inference engine (problem-solver). Based on the general approach and experience of EOPTS, the authors have developed a prototype procedures monitoring system that reads MAAP transient output files and evaluate the EOP messages and instructions that would be implied during each transient time interval. The prototype system was built using the NEXPERT OBJECT expert system development system, running on a 386-class personal computer with 4 MB of memory. The limited scope prototype includes a reduced set of BWR6 EOPs procedures evaluation on a coarse time interval, a simple text-based user interface, and a summary-report generator. The prototype, which is limited to batch-mode analysis of MAAP output, is intended to demonstrate the concept and aid in the design of a production system, which will involve a direct link to MAAP and interactive capabilities

  14. A tool model for predicting atmospheric kinetics with sensitivity analysis

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A package( a tool model) for program of predicting atmospheric chemical kinetics with sensitivity analysis is presented. The new direct method of calculating the first order sensitivity coefficients using sparse matrix technology to chemical kinetics is included in the tool model, it is only necessary to triangularize the matrix related to the Jacobian matrix of the model equation. The Gear type procedure is used to integrate amodel equation and its coupled auxiliary sensitivity coefficient equations. The FORTRAN subroutines of the model equation, the sensitivity coefficient equations, and their Jacobian analytical expressions are generated automatically from a chemical mechanism. The kinetic representation for the model equation and its sensitivity coefficient equations, and their Jacobian matrix is presented. Various FORTRAN subroutines in packages, such as SLODE, modified MA28, Gear package, with which the program runs in conjunction are recommended.The photo-oxidation of dimethyl disulfide is used for illustration.

  15. Interventional chest procedures in pregnancy.

    LENUS (Irish Health Repository)

    Morgan, Ross K

    2012-02-01

    Interventional pulmonology encompasses diagnostic and therapeutic bronchoscopic procedures, and pleural interventions. In the last 10 years older techniques have been refined and exciting new technologies have extended the reach and application of the instruments used. The main areas within pulmonary medicine for which these interventions have a role are malignant and nonmalignant airway disease, pleural effusion, pneumothorax, and artificial airways. There are no data from well-designed prospective trials to guide recommendations for interventional pulmonary procedures in pregnancy. The recommendations provided in this article are based on critical review of reported case series, opinion from recognized experts, and personal observations.

  16. Interventional chest procedures in pregnancy.

    LENUS (Irish Health Repository)

    Morgan, Ross K

    2011-03-01

    Interventional pulmonology encompasses diagnostic and therapeutic bronchoscopic procedures, and pleural interventions. In the last 10 years older techniques have been refined and exciting new technologies have extended the reach and application of the instruments used. The main areas within pulmonary medicine for which these interventions have a role are malignant and nonmalignant airway disease, pleural effusion, pneumothorax, and artificial airways. There are no data from well-designed prospective trials to guide recommendations for interventional pulmonary procedures in pregnancy. The recommendations provided in this article are based on critical review of reported case series, opinion from recognized experts, and personal observations.

  17. Examining procedural working memory processing in obsessive-compulsive disorder.

    Science.gov (United States)

    Shahar, Nitzan; Teodorescu, Andrei R; Anholt, Gideon E; Karmon-Presser, Anat; Meiran, Nachshon

    2017-07-01

    Previous research has suggested that a deficit in working memory might underlie the difficulty of obsessive-compulsive disorder (OCD) patients to control their thoughts and actions. However, a recent meta-analyses found only small effect sizes for working memory deficits in OCD. Recently, a distinction has been made between declarative and procedural working memory. Working memory in OCD was tested mostly using declarative measurements. However, OCD symptoms typically concerns actions, making procedural working-memory more relevant. Here, we tested the operation of procedural working memory in OCD. Participants with OCD and healthy controls performed a battery of choice reaction tasks under high and low procedural working memory demands. Reaction-times (RT) were estimated using ex-Gaussian distribution fitting, revealing no group differences in the size of the RT distribution tail (i.e., τ parameter), known to be sensitive to procedural working memory manipulations. Group differences, unrelated to working memory manipulations, were found in the leading-edge of the RT distribution and analyzed using a two-stage evidence accumulation model. Modeling results suggested that perceptual difficulties might underlie the current group differences. In conclusion, our results suggest that procedural working-memory processing is most likely intact in OCD, and raise a novel, yet untested assumption regarding perceptual deficits in OCD. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  18. Culture-sensitive psychotraumatology

    Science.gov (United States)

    Schnyder, Ulrich; Bryant, Richard A.; Ehlers, Anke; Foa, Edna B.; Hasan, Aram; Mwiti, Gladys; Kristensen, Christian H.; Neuner, Frank; Oe, Misari; Yule, William

    2016-01-01

    Background Although there is some evidence of the posttraumatic stress disorder (PTSD) construct's cross cultural validity, trauma-related disorders may vary across cultures, and the same may be true for treatments that address such conditions. Experienced therapists tailor psychotherapy to each patient's particular situation, to the nature of the patient's psychopathology, to the stage of therapy, and so on. In addition, culture-sensitive psychotherapists try to understand how culture enhances the meaning of their patient's life history, the cultural components of their illness and help-seeking behaviors, as well as their expectations with regard to treatment. We cannot take for granted that all treatment-seeking trauma survivors speak our language or share our cultural values. Therefore, we need to increase our cultural competencies. Methods The authors of this article are clinicians and/or researchers from across the globe, working with trauma survivors in various settings. Each author focused on one or more specific cultural aspects of working with trauma survivors and highlighted the following aspects. Results As a result of culture-specific individual and collective meanings linked to trauma and trauma-related disorders survivors may be exposed to (self-)stigma in the aftermath of trauma. Patients who are reluctant to talk about their traumatic experiences may instead be willing to write or use other ways of accessing the painful memories such as drawing. In other cultures, community and family cohesion are crucial elements of recovery. While awareness of culture-specific aspects is important, we also need to beware of premature cultural stereotyping. When disseminating empirically supported psychotherapies for PTSD across cultures, a number of additional challenges need to be taken into account: many low and middle income countries have very limited resources available and suffer from a poor health infrastructure. Conclusions In summary, culture-sensitive

  19. Validity of diagnoses, procedures, and laboratory data in Japanese administrative data.

    Science.gov (United States)

    Yamana, Hayato; Moriwaki, Mutsuko; Horiguchi, Hiromasa; Kodan, Mariko; Fushimi, Kiyohide; Yasunaga, Hideo

    2017-10-01

    Validation of recorded data is a prerequisite for studies that utilize administrative databases. The present study evaluated the validity of diagnoses and procedure records in the Japanese Diagnosis Procedure Combination (DPC) data, along with laboratory test results in the newly-introduced Standardized Structured Medical Record Information Exchange (SS-MIX) data. Between November 2015 and February 2016, we conducted chart reviews of 315 patients hospitalized between April 2014 and March 2015 in four middle-sized acute-care hospitals in Shizuoka, Kochi, Fukuoka, and Saga Prefectures and used them as reference standards. The sensitivity and specificity of DPC data in identifying 16 diseases and 10 common procedures were identified. The accuracy of SS-MIX data for 13 laboratory test results was also examined. The specificity of diagnoses in the DPC data exceeded 96%, while the sensitivity was below 50% for seven diseases and variable across diseases. When limited to primary diagnoses, the sensitivity and specificity were 78.9% and 93.2%, respectively. The sensitivity of procedure records exceeded 90% for six procedures, and the specificity exceeded 90% for nine procedures. Agreement between the SS-MIX data and the chart reviews was above 95% for all 13 items. The validity of diagnoses and procedure records in the DPC data and laboratory results in the SS-MIX data was high in general, supporting their use in future studies. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  20. FFTF operations procedures preparation guide. Revision 2

    International Nuclear Information System (INIS)

    1976-12-01

    The Guide is intended to provide guidelines for the initial preparation of FFTF Operating Procedures. The Procedures Preparation Guide was developed from the plan presented and approved in the FFTF Reactor Plant Procedures Plan, PC-1, Revision 3

  1. SOX sensitivity study

    Energy Technology Data Exchange (ETDEWEB)

    Martyn, Johann [Johannes Gutenberg-Universitaet, Mainz (Germany); Collaboration: BOREXINO-Collaboration

    2016-07-01

    To this day most experimental results on neutrino oscillations can be explained in the standard three neutrino model. There are however a few experiments that show anomalous behaviour at a very short baselines. These anomalies can hypothetically be explained with the existence of one or additional more light neutrino states that do not take part in weak interactions and are thus called sterile. Although the anomalies only give a hint that such sterile neutrinos could exist the prospect for physics beyond the standard model is a major motivation to investigate the neutrino oscillations in new very short baseline experiments. The SOX (Short distance Oscillations in BoreXino) experiment will use the Borexino detector and a {sup 144}Ce source to search for sterile neutrinos via the occurance of an oscillation pattern at a baseline of several meters. This talk examines the impact of the Borexino detector systematics on the experimental sensitivity of SOX.

  2. Context Sensitive Health Informatics

    DEFF Research Database (Denmark)

    involves careful consideration of both human and organizational factors. This book presents the proceedings of the Context Sensitive Health Informatics (CSHI) conference, held in Copenhagen, Denmark, in August 2013. The theme of this year’s conference is human and sociotechnical approaches. The Human...... different healthcare contexts. Healthcare organizations, health policy makers and regulatory bodies globally are starting to acknowledge this essential role of human and organizational factors for safe and effective health information technology. This book will be of interest to all those involved......Healthcare information technologies are now routinely deployed in a variety of healthcare contexts. These contexts differ widely, but the smooth integration of IT systems is crucial, so the design, implementation, and evaluation of safe, effective, efficient and easy to adopt health informatics...

  3. Beyond sensitivity analysis

    DEFF Research Database (Denmark)

    Lund, Henrik; Sorknæs, Peter; Mathiesen, Brian Vad

    2018-01-01

    of electricity, which have been introduced in recent decades. These uncertainties pose a challenge to the design and assessment of future energy strategies and investments, especially in the economic assessment of renewable energy versus business-as-usual scenarios based on fossil fuels. From a methodological...... point of view, the typical way of handling this challenge has been to predict future prices as accurately as possible and then conduct a sensitivity analysis. This paper includes a historical analysis of such predictions, leading to the conclusion that they are almost always wrong. Not only...... are they wrong in their prediction of price levels, but also in the sense that they always seem to predict a smooth growth or decrease. This paper introduces a new method and reports the results of applying it on the case of energy scenarios for Denmark. The method implies the expectation of fluctuating fuel...

  4. EV range sensitivity analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ostafew, C. [Azure Dynamics Corp., Toronto, ON (Canada)

    2010-07-01

    This presentation included a sensitivity analysis of electric vehicle components on overall efficiency. The presentation provided an overview of drive cycles and discussed the major contributors to range in terms of rolling resistance; aerodynamic drag; motor efficiency; and vehicle mass. Drive cycles that were presented included: New York City Cycle (NYCC); urban dynamometer drive cycle; and US06. A summary of the findings were presented for each of the major contributors. Rolling resistance was found to have a balanced effect on each drive cycle and proportional to range. In terms of aerodynamic drive, there was a large effect on US06 range. A large effect was also found on NYCC range in terms of motor efficiency and vehicle mass. figs.

  5. Guide to Alabama Court Procedures.

    Science.gov (United States)

    Alabama Administrative Office of Courts, Montgomery.

    Designed to assist the public in understanding the judicial system and judicial process in Alabama, this handbook (1) presents an overview of Alabama's courts and their jurisdictions, (2) identifies the officers of the courts and the contributions each makes to the judicial process, and (3) narrates in general terms the procedures most common to…

  6. On Procedural Freedom of Choice

    NARCIS (Netherlands)

    Arlegi, R.; Dimitrov, D.A.

    2004-01-01

    Numerous works in the last decade have analyzed the question of how to compare opportunity sets as a way to measure and evaluate individual freedom of choice.This paper defends that, in many contexts, external procedural aspects that are associated to an opportunity set should be taken into account

  7. Core calculational techniques and procedures

    International Nuclear Information System (INIS)

    Romano, J.J.

    1977-10-01

    Described are the procedures and techniques employed by B and W in core design analyses of power peaking, control rod worths, and reactivity coefficients. Major emphasis has been placed on current calculational tools and the most frequently performed calculations over the operating power range

  8. Environmental Impact Assessment: A Procedure.

    Science.gov (United States)

    Stover, Lloyd V.

    Prepared by a firm of consulting engineers, this booklet outlines the procedural "whys and hows" of assessing environmental impact, particularly for the construction industry. Section I explores the need for environmental assessment and evaluation to determine environmental impact. It utilizes a review of the National Environmental Policy Act and…

  9. International evaluation procedure for Supergrants

    OpenAIRE

    2010-01-01

    Sergey Ivanets, director of the department of international integration at the Ministry of Education and Science, talks about the specifics of the evaluation procedures for inviting leading scientists (Decree of the Government of the Russian Federation dated April 9, 2010, N 220: "On Measures for Attracting Leading Scientists into Russian Higher Professional Educational Institutions")

  10. Cognitive Procedures and Hyperbolic Discounting

    NARCIS (Netherlands)

    Nir, A.

    2004-01-01

    "Hyperbolic discount functions are characterized by a relatively high discount rate over short horizons and a relatively low discount rate over long horizons" (Laibson 1997).We suggest two cognitive procedures where individuals perceive future utility as decreasing at a decreasing rate as a function

  11. Safety procedures for radiography works

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Work preparation: before exposure, during exposure, after work completion. Radiographic work at the open site: types of open sites, establishment of radiographic boundary, storage of radiographic equipment at sites. Safety procedures for radiography works; radiographic works in exposure room

  12. Postoperative Complications of Beger Procedure

    Directory of Open Access Journals (Sweden)

    Nayana Samejima Peternelli

    2015-01-01

    Full Text Available Introduction. Chronic pancreatitis (CP is considered an inflammatory disease that may cause varying degrees of pancreatic dysfunction. Conservative and surgical treatment options are available depending on dysfunction severity. Presentation of Case. A 36-year-old male with history of heavy alcohol consumption and diagnosed CP underwent a duodenal-preserving pancreatic head resection (DPPHR or Beger procedure after conservative treatment failure. Refractory pain was reported on follow-up three months after surgery and postoperative imaging uncovered stones within the main pancreatic duct and intestinal dilation. The patient was subsequently subjected to another surgical procedure and intraoperative findings included protein plugs within the main pancreatic duct and pancreaticojejunal anastomosis stricture. A V-shaped enlargement and main pancreatic duct dilation in addition to the reconstruction of the previous pancreaticojejunal anastomosis were performed. The patient recovered with no further postoperative complications in the follow-up at an outpatient clinic. Discussion. Main duct and pancreaticojejunal strictures are an unusual complication of the Beger procedure but were identified intraoperatively as the cause of patient’s refractory pain and explained intraductal protein plugs accumulation. Conclusion. Patients that undergo Beger procedures should receive close outpatient clinical follow-up in order to guarantee postoperative conservative treatment success and therefore guarantee an early detection of postoperative complications.

  13. Procedural learning during declarative control.

    Science.gov (United States)

    Crossley, Matthew J; Ashby, F Gregory

    2015-09-01

    There is now abundant evidence that human learning and memory are governed by multiple systems. As a result, research is now turning to the next question of how these putative systems interact. For instance, how is overall control of behavior coordinated, and does learning occur independently within systems regardless of what system is in control? Behavioral, neuroimaging, and neuroscience data are somewhat mixed with respect to these questions. Human neuroimaging and animal lesion studies suggest independent learning and are mostly agnostic with respect to control. Human behavioral studies suggest active inhibition of behavioral output but have little to say regarding learning. The results of two perceptual category-learning experiments are described that strongly suggest that procedural learning does occur while the explicit system is in control of behavior and that this learning might be just as good as if the procedural system was controlling the response. These results are consistent with the idea that declarative memory systems inhibit the ability of the procedural system to access motor output systems but do not prevent procedural learning. (c) 2015 APA, all rights reserved).

  14. Current procedural terminology; a primer.

    Science.gov (United States)

    Hirsch, Joshua A; Leslie-Mazwi, Thabele M; Nicola, Gregory N; Barr, Robert M; Bello, Jacqueline A; Donovan, William D; Tu, Raymond; Alson, Mark D; Manchikanti, Laxmaiah

    2015-04-01

    In 1966, The American Medical Association (AMA) working with multiple major medical specialty societies developed an iterative coding system for describing medical procedures and services using uniform language, the Current Procedural Terminology (CPT) system. The current code set, CPT IV, forms the basis of reporting most of the services performed by healthcare providers, physicians and non-physicians as well as facilities allowing effective, reliable communication among physician and other providers, third parties and patients. This coding system and its maintenance has evolved significantly since its inception, and now goes well beyond its readily perceived role in reimbursement. Additional roles include administrative management, tracking new and investigational procedures, and evolving aspects of 'pay for performance'. The system also allows for local, regional and national utilization comparisons for medical education and research. Neurointerventional specialists use CPT category I codes regularly--for example, 36,215 for first-order cerebrovascular angiography, 36,216 for second-order vessels, and 37,184 for acute stroke treatment by mechanical means. Additionally, physicians add relevant modifiers to the CPT codes, such as '-26' to indicate 'professional charge only,' or '-59' to indicate a distinct procedural service performed on the same day. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Development of Charge Sensitive Preamplifier and Readout Integrate Circuit Board for High Resolution Detector using ASIC Process

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, J. Y.; Kim, J. H.; Park, J. M.; Yang, J. Y.; Kim, K. Y.; Kim, Y. S. [RadTek Co., Daejeon (Korea, Republic of)

    2010-06-15

    - Design of discrete type charge sensitive amplifier for high resolution semi-conductor sensor - Design and develop the test board for the performance of charge sensitive amplifier with sensor - Performance of electrical test for the sensor and charge sensitive amplifier - Development of prototype 8 x 8 array type detector module - Noise equivalent charge test for the charge sensitive amplifier - Design and development of Micro SMD discrete type amplifier applying ASIC procedure - Development of Hybrid type charge sensitive amplifier including shape

  16. Computational Methods for Sensitivity and Uncertainty Analysis in Criticality Safety

    International Nuclear Information System (INIS)

    Broadhead, B.L.; Childs, R.L.; Rearden, B.T.

    1999-01-01

    Interest in the sensitivity methods that were developed and widely used in the 1970s (the FORSS methodology at ORNL among others) has increased recently as a result of potential use in the area of criticality safety data validation procedures to define computational bias, uncertainties and area(s) of applicability. Functional forms of the resulting sensitivity coefficients can be used as formal parameters in the determination of applicability of benchmark experiments to their corresponding industrial application areas. In order for these techniques to be generally useful to the criticality safety practitioner, the procedures governing their use had to be updated and simplified. This paper will describe the resulting sensitivity analysis tools that have been generated for potential use by the criticality safety community

  17. Sensitivity and uncertainty analysis of the PATHWAY radionuclide transport model

    International Nuclear Information System (INIS)

    Otis, M.D.

    1983-01-01

    Procedures were developed for the uncertainty and sensitivity analysis of a dynamic model of radionuclide transport through human food chains. Uncertainty in model predictions was estimated by propagation of parameter uncertainties using a Monte Carlo simulation technique. Sensitivity of model predictions to individual parameters was investigated using the partial correlation coefficient of each parameter with model output. Random values produced for the uncertainty analysis were used in the correlation analysis for sensitivity. These procedures were applied to the PATHWAY model which predicts concentrations of radionuclides in foods grown in Nevada and Utah and exposed to fallout during the period of atmospheric nuclear weapons testing in Nevada. Concentrations and time-integrated concentrations of iodine-131, cesium-136, and cesium-137 in milk and other foods were investigated. 9 figs., 13 tabs

  18. Culture-sensitive psychotraumatology

    Directory of Open Access Journals (Sweden)

    Ulrich Schnyder

    2016-07-01

    Full Text Available Background: Although there is some evidence of the posttraumatic stress disorder (PTSD construct's cross cultural validity, trauma-related disorders may vary across cultures, and the same may be true for treatments that address such conditions. Experienced therapists tailor psychotherapy to each patient's particular situation, to the nature of the patient's psychopathology, to the stage of therapy, and so on. In addition, culture-sensitive psychotherapists try to understand how culture enhances the meaning of their patient's life history, the cultural components of their illness and help-seeking behaviors, as well as their expectations with regard to treatment. We cannot take for granted that all treatment-seeking trauma survivors speak our language or share our cultural values. Therefore, we need to increase our cultural competencies. Methods: The authors of this article are clinicians and/or researchers from across the globe, working with trauma survivors in various settings. Each author focused on one or more specific cultural aspects of working with trauma survivors and highlighted the following aspects. Results: As a result of culture-specific individual and collective meanings linked to trauma and trauma-related disorders survivors may be exposed to (self-stigma in the aftermath of trauma. Patients who are reluctant to talk about their traumatic experiences may instead be willing to write or use other ways of accessing the painful memories such as drawing. In other cultures, community and family cohesion are crucial elements of recovery. While awareness of culture-specific aspects is important, we also need to beware of premature cultural stereotyping. When disseminating empirically supported psychotherapies for PTSD across cultures, a number of additional challenges need to be taken into account: many low and middle income countries have very limited resources available and suffer from a poor health infrastructure. Conclusions: In summary

  19. MOVES regional level sensitivity analysis

    Science.gov (United States)

    2012-01-01

    The MOVES Regional Level Sensitivity Analysis was conducted to increase understanding of the operations of the MOVES Model in regional emissions analysis and to highlight the following: : the relative sensitivity of selected MOVES Model input paramet...

  20. Cooling, cryporitectant and hypersaline sensitivity of Penaeid shrimp embryos and nauplii larvae

    NARCIS (Netherlands)

    Alfaro Montoya, J.; Komen, J.; Huisman, E.A.

    2001-01-01

    The sensitivity of embryos of the penaeid shrimp, Trachypenaeus byrdi, to cooling, cryoprotectant exposure (dimethyl sulfoxide : DMSO, sucrose, methanol and glycerol), and hypersaline treatment was assessed in order to gain basic knowledge for cryopreservation procedures. In addition, cooling and

  1. Procedural Personas for Player Decision Modeling and Procedural Content Generation

    DEFF Research Database (Denmark)

    Holmgård, Christoffer

    2016-01-01

    ." These methods for constructing procedural personas are then integrated with existing procedural content generation systems, acting as critics that shape the output of these systems, optimizing generated content for different personas and by extension, different kinds of players and their decision making styles......How can player models and artificially intelligent (AI) agents be useful in early-stage iterative game and simulation design? One answer may be as ways of generating synthetic play-test data, before a game or level has ever seen a player, or when the sampled amount of play test data is very low....... This thesis explores methods for creating low-complexity, easily interpretable, generative AI agents for use in game and simulation design. Based on insights from decision theory and behavioral economics, the thesis investigates how player decision making styles may be defined, operationalised, and measured...

  2. A Posteriori Finite Element Bounds for Sensitivity Derivatives of Partial-Differential-Equation Outputs. Revised

    Science.gov (United States)

    Lewis, Robert Michael; Patera, Anthony T.; Peraire, Jaume

    1998-01-01

    We present a Neumann-subproblem a posteriori finite element procedure for the efficient and accurate calculation of rigorous, 'constant-free' upper and lower bounds for sensitivity derivatives of functionals of the solutions of partial differential equations. The design motivation for sensitivity derivative error control is discussed; the a posteriori finite element procedure is described; the asymptotic bounding properties and computational complexity of the method are summarized; and illustrative numerical results are presented.

  3. Sensitivity Analysis in Ictneo

    Energy Technology Data Exchange (ETDEWEB)

    Bielza, C.; Rios-Insua, S.; Gomez, M.; Fernandez del Pozo, J. A.

    2001-07-01

    Neonatal jaundice is a common medical problem which arises in a healthy newborn because of the breakdown of excess red blood cells in his system. Bilirubin accumulates when the liver does not excrete it at a normal rate. Pathological jaundice may cause potentially serious central nervous system damages. Current recommendations try to balance out the risks of under treatment and over treatment, but the current protocol does not delimit clearly when it is best to start each treatment and which treatment to administer. As a consequence of this difficulty among others, the Neonatology Service of Gregorio Maranon Hospital in Madrid suggested the development of a decision support system IctNeo to provide the doctors with an automated problem-solving tool as an aid improving jaundice management. The development of the system has been very complex and time consuming, both the structuring of the diagram and the elicitation of probabilities and utilities. IctNeo finds a maximum expected utility treatment strategy based on an influence diagram (ID). Due to the computational intractability of its large ID, IctNeo incorporates some procedures to the standard evaluation algorithm. A user-friendly interface allows for data entry of a patient already treated by the doctor. Then, we can compare the system recommendations and the doctor decisions in order to draw conclusions. (Author) 5 refs.

  4. A frame work for heat generation/absorption and modified homogeneous–heterogeneous reaction in flow based on non-Darcy–Forchheimer medium

    Directory of Open Access Journals (Sweden)

    Tasawar Hayat

    2018-04-01

    Full Text Available The present work aims to report the consequences of Darcy–Forchheimer medium in flow of Cross fluid model toward a stretched surface. Flow in porous space is categorized by Darcy–Forchheimer medium. Further heat transfer characteristics are examined via thermal radiation and heat generation/absorption. Transformation procedure is used. The arising system of nonlinear ordinary differential equations is solved numerically by means of shooting method. The effects of different flow variables on velocity, temperature, concentration, skin friction, and heat transfer rate are discussed. The obtained outcomes show that velocity was enhanced with the increase in the Weissenberg number but decays with increase in the porosity parameter and Hartman number. Temperature field is boosted by thermal radiation and heat generation; however, it decays with the increase in the Prandtl number. Keywords: Cross Fluid, Heat Generation/Absorption, Homogeneous–Heterogeneous Reactions, Non-Darcy–Forchheimer Medium, Thermal Radiation

  5. Stellarator Coil Design and Plasma Sensitivity

    International Nuclear Information System (INIS)

    Ku, Long-Poe; Boozer, Allen H.

    2010-01-01

    The rich information contained in the plasma response to external magnetic perturbations can be used to help design stellarator coils more effectively. We demonstrate the feasibility by first devel oping a simple, direct method to study perturbations in stellarators that do not break stellarator symmetry and periodicity. The method applies a small perturbation to the plasma boundary and evaluates the resulting perturbed free-boundary equilibrium to build up a sensitivity matrix for the important physics attributes of the underlying configuration. Using this sensitivity information, design methods for better stellarator coils are then developed. The procedure and a proof-of-principle application are given that (1) determine the spatial distributions of external normal magnetic field at the location of the unperturbed plasma boundary to which the plasma properties are most sen- sitive, (2) determine the distributions of external normal magnetic field that can be produced most efficiently by distant coils, (3) choose the ratios of the magnitudes of the the efficiently produced magnetic distributions so the sensitive plasma properties can be controlled. Using these methods, sets of modular coils are found for the National Compact Stellarator Experiment (NCSX) that are either smoother or can be located much farther from the plasma boundary than those of the present design.

  6. Biomonitoring test procedures and biological criteria

    Energy Technology Data Exchange (ETDEWEB)

    Kszos, L.A. [Oak Ridge National Lab., TN (United States); Lipschultz, M.J. [City of Las Vegas, NV (United States); Foster, W.E. [Saint Mary`s Coll., Winona, MN (United States)

    1997-10-01

    The Water Environment Federation recently issued a special publication, Biomonitoring in the Water Environment. In this paper, the authors highlight the contents of the chapter 3, Biomonitoring Test Procedures, identify current trends in test procedures and introduce the concept of biological criteria (biocriteria). The book chapter (and this paper) focuses on freshwater and marine chronic and acute toxicity tests used in the National Pollutant Discharge Elimination System (NPDES) permits program to identify effluents and receiving waters containing toxic materials in acutely or chronically toxic concentrations. The two major categories of toxicity tests include acute tests and chronic tests. The USEPA chronic tests required in NPDEs permits have been shortened to 7 days by focusing on the most sensitive life-cycle stages; these tests are often referred to as short-term chronic tests. The type of test(s) required depend on NPDES permit requirements, objectives of the test, available resources, requirements of the test organisms, and effluent characteristics such as variability in flow or toxicity. The permit writer will determine the requirements for toxicity test(s) by considering such factors as dilution, effluent variability, and exposure variability. Whether the required test is acute or chronic, the objective of the test is to estimate the safe or no effect concentration which is defined as the concentration which will permit normal propagation of fish and other aquatic life in the receiving waters. In this paper, the authors review the types of toxicity tests, the commonly used test organisms, and the uses of toxicity test data. In addition, they briefly describe research on new methods and the use of biological criteria.

  7. Sex: a sensitive issue.

    Science.gov (United States)

    1997-01-01

    Health care workers and educators may need to improve their skills in discussing sensitive issues in order to elicit and understand what influences people's attitudes toward sex. While the health worker may be bent upon preventing HIV infection, advising on family planning, or teaching youth about sexual relationships, his or her audience may have other priorities. A good counselor/teacher must learn what people's concerns are and discuss sexual health within that context. It can be difficult talking about sex because sex is a private concern and many people are embarrassed discussing it. Even sex partners often find it difficult to talk to each other about sex. Appropriate communication techniques vary depending upon the situation. It depends upon whether one is addressing people on an individual basis or in groups, which people are being addressed, which organization one is representing, and what one's role is. Good communication is a two-way sharing of information. The different stages of life, common beliefs and myths, culture and religion, relationships between men and women, reasons for having sex, and sex practices are discussed.

  8. Hypoxic sensitizers (A review)

    International Nuclear Information System (INIS)

    Ohno, Tadao; Shikita, Mikio

    1976-01-01

    Since the early works of Bridges (1960) and Adams (1963), electron-affinic compounds have long been the subject of a number of studies in the search for a drug which sensitizes radio-resistant hypoxic tumor cells for improvement of radiotherapy of cancer. However, clinical application of this kind of drugs has been hampered by the fact that most of the compounds which exhibited radiosensitizing action in vitro exerted no such action against hypoxic tumor cells in vivo, because of rapid metabolical decomposition or because of great toxicity in vivo. Low solubility of these compounds in aqueous solution was another problem which made it difficult to use the compounds in proper concentrations. The authors have found that furylfuramide (AF-2), possesses a typical radiosensitizing potency. The radiosensitizing action of AF-2 was demonstrated in hypoxic yeasts as well as in mouse leukemic cells (L-5178 Y). Injection of 4.7 μg of AF-2 into a mouse mammary carcinoma 5 min before a single dose (3500 rad) of x-irradiation reduced regrowth of the tumors to a greater extent than irradiation alone, giving an enhancing ratio of 1.6. The effect of AF-2 was insignificant when radiation was given in divided doses (800 rad for 5 times) with the drug injected each time prior to irradiation. (auth.)

  9. Radiation Sensitivity of Societies

    International Nuclear Information System (INIS)

    Uray, I.; Hille, R.; Rohloff, F.

    1998-01-01

    Investigating the mean dose values as well as dose distributions of the inhabitants in a large number of settlements maybe set down, that the generally calculated mean exposure is a good measure to estimate the collective dose for a settlement or for a large region. Its uncertainty is however too high, and the dose distribution is very broad (250-300%) to estimate the external exposure of any single person. However, models may take into account more details of influencing factors. First of all the surveying of the local contamination density distribution could be more detailed and more accurate. Measure and distribution of the internal exposure (is not the subject of the present work, but it is similarly problematic. In this situation it is very difficult to search the dose-effect relationships exactly, and is also difficult to satisfy the people that their fears are unjustified. Society pays the costs of the nuclear industry and of the possible consequences as well. But society can neither control the nuclear industry nor the possible consequences at all. Both science and single people are waiting for more and detailed information. If we can not decrease the r adiation sensitivity of societies , then the consequences of Chernobyl will be growing unnecessarily, and it can strongly retard the justified development of the nuclear industry as well. (author)

  10. Hypoxic-cell sensitizers

    International Nuclear Information System (INIS)

    Dische, S.

    1983-01-01

    There is now 6 years of clinical experience with misonidazole as a hypoxic-cell sensitizer. Neurotoxicity limits the total dose which may be given, and so relatively low concentrations of radiosensitizing drugs are likely to be achieved in hypoxic cells in man as compared with those in animal tumors. It is likely that benefit will only be shown in those situations where radioresistant hypoxic cells strongly dominate as a cause of radiation failure. Many clinical trials are underway, and thus far some show no benefit while in others there is a definite advantage to the patients given the drug. These trials must be continued to their conclusion, but misonidazole must be regarded as the first of a series of radiosensitizers to reach the clinic for trial. There is a promise of more effective drugs becoming available within the next few years. Those showing a lower lipophilicity than misonidazole have been found to have a shorter half-life and a lower uptake in neural tissue in animal studies. One such drug, desmethylmisonidazole, is presently undergoing clinical trial

  11. Pediatric procedural sedation and analgesia

    Directory of Open Access Journals (Sweden)

    Meredith James

    2008-01-01

    Full Text Available Procedural sedation and analgesia (PSA is an evolving field in pediatric emergency medicine. As new drugs breach the boundaries of anesthesia in the Pediatric Emergency Department, parents, patients, and physicians are finding new and more satisfactory methods of sedation. Short acting, rapid onset agents with little or no lingering effects and improved safety profiles are replacing archaic regimens. This article discusses the warning signs and areas of a patient′s medical history that are particularly pertinent to procedural sedation and the drugs used. The necessary equipment is detailed to provide the groundwork for implementing safe sedation in children. It is important for practitioners to familiarize themselves with a select few of the PSA drugs, rather than the entire list of sedatives. Those agents most relevant to PSA in the pediatric emergency department are presented.

  12. Investigative procedures in thyroid cancer

    International Nuclear Information System (INIS)

    Samuel, A.M.

    1999-01-01

    One of the main objectives of the procedures is to establish the likelihood of malignancy in the thyroid gland prior to surgery and detect metastases after surgery. Thyroid imaging is discussed in the context of (a) its role in the diagnosis of the primary disease (b) in the investigation of post-operative residual disease and (c) its role in the follow-up of patients after radioiodine therapy

  13. New procedures in nuclear medicine

    International Nuclear Information System (INIS)

    Spencer, R.P.

    1989-01-01

    The authors review the recent emergence of functional studies in nuclear medicine in this critical and informative text. The new procedures are presented in terms of their underlying physiology, indications, contraindications, methodology, results, interpretation and relationship to other evaluations. The volume includes discussions on the central nervous system, interventional studies, cardiac studies, bone densitometry, plus radiolabeled antibodies, radiolabeling of blood elements and flow and distribution

  14. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    RW Hanf; TM Poston

    2000-09-20

    Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual.

  15. Operating procedures and safety culture

    International Nuclear Information System (INIS)

    Carnino, A.

    1993-01-01

    The development of new technologies in recent years has led to a tremendous increase in the information to be mastered by operators in industrial processes. The information at operators disposal both in routine situations and accidental ones needs to be well prepared and organized to ensure reliability and safety. The man-machine interface should give operators all the necessary and clear indications on the process status and evolution so that the operators can operate the installation through adequate procedures. Procedures represent the real interface and mode of action of the operators on the machine, and they are of prime importance. Although they are by essence quite different, the routine, accident, and emergency procedures have in common one attribute: They all require a good safety culture both in their development and their implementation. From the definition given by the members of the International Nuclear Safety Advisory Group (INSAG), open-quotes Safety culture is that assembly of characteristics and attitudes in organizations and individuals which establishes that, as an overriding priority, nuclear plant safety issues receive the attention warranted by their significance,close quotes one can see that two aspects are embedded, a collective attitude that in fact is reflected in the managerial framework and an individual one that is linked to personnel behavior and work practices

  16. Computer managed emergency operating procedures

    International Nuclear Information System (INIS)

    Salamun, I.; Mavko, B.; Stritar, A.

    1994-01-01

    New computer technology is a very effective tool for developing a new design of nuclear power plant control room. It allows designer possibility to create a tool for managing with large database of power plant parameters and displaying them in different graphic forms and possibility of automated execution of well known task. The structure of Emergency Operating Procedures (EOP) is very suitable for programming and for creating expert system. The Computerized Emergency Operating Procedures (CEOP) described in this paper can be considered as an upgrading of standard EOP approach. EmDiSY (Emergency Display System - computer code name for CEOP) main purpose is to supply the operator with necessary information, to document all operator actions and to execute well known tasks. It is a function oriented CEOP that gives operator guidance on how to verify the critical safety functions and how to restore and maintain these functions where they are degraded. All knowledge is coded and stored in database files. The knowledge base consists from stepping order for verifying plant parameters, desired values of parameters, conditions for comparison and links between procedures and actions. Graphical shell allows users to read database, to follow instruction and to find out correct task. The desired information is concentrated in one screen and allows users to focus on a task. User is supported in two ways: desired parameter values are displayed on the process picture and automated monitoring critical safety function status trees are all time in progress and available to the user. (author). 4 refs, 4 figs

  17. INADMISSIBLE EVIDENCE IN CIVIL PROCEDURE

    Directory of Open Access Journals (Sweden)

    Mihajlo Dika

    2016-01-01

    Full Text Available This paper examines the exclusion of specific means of evidence as instruments for determining the object of evidence, as well as the taking of evidence in the framework of the Croatian civil procedure law. The introduction lays the grounds for classifying and qualifying exclusion of evidence (general, special; absolute, relative; removable, irremovable; direct, indirect, after which greater attention is paid to the so called absolute and relative type; exclusionary evidence of the direct relative type pertaining to the establishing of facts, and evidence dismissals. With regard to the indirect relative type, the paper examines exclusionary evidence concerning the object of evidence. The remainder of the paper focuses on illegally obtained evidence, while outlining the constitutional, statutory, judicature and doctrinaire premises of bearing for such evidence. Subsequently, the question of evidence obtained in violation of the Constitutional guarantee of respect and legal protection of private and family life, dignity, reputation and honour, as well as evidence obtained by breach of the Constitutional guarantee of freedom and secrecy of correspondence and all other forms of communication, and in violation of the right to safety and privacy of personal data, are discussed too. In addition, the paper analyses the institutions of preclusion of evidence and the so called informative evidence. Concluding, the author points to a lacking regulation of inadmissible evidence within the Croatian civil procedure law, underlining the need to determine de lege ferenda legal requirements with a view to operationalizing inadmissible evidence within the Croatian civil procedure law.

  18. 18 CFR 301.3 - Filing procedures.

    Science.gov (United States)

    2010-04-01

    ... FOR SALES FROM UTILITIES TO BONNEVILLE POWER ADMINISTRATION UNDER NORTHWEST POWER ACT § 301.3 Filing procedures. (a) Bonneville's ASC review procedures. The procedures established by Bonneville's Administrator... Bonneville's ASC review procedures. (b) Exchange Period. The Exchange Period will be equal to the term of...

  19. An improved ashing procedure for biologic sample

    Energy Technology Data Exchange (ETDEWEB)

    Zongmei, Wu [Zhejiang Province Enviromental Radiation Monitoring Centre (China)

    1992-07-01

    The classical ashing procedure in muffle was modified for biologic samples. In the modified procedure the door of muffle was open in the duration of ashing process, the ashing was accelerated and the ashing product quality was comparable to that the classical procedure. The modified procedure is suitable for ashing biologic samples in large batches.

  20. An improved ashing procedure for biologic sample

    International Nuclear Information System (INIS)

    Wu Zongmei

    1992-01-01

    The classical ashing procedure in muffle was modified for biologic samples. In the modified procedure the door of muffle was open in the duration of ashing process, the ashing was accelerated and the ashing product quality was comparable to that the classical procedure. The modified procedure is suitable for ashing biologic samples in large batches

  1. Series expansion of the modified Einstein Procedure

    Science.gov (United States)

    Seema Chandrakant Shah-Fairbank

    2009-01-01

    This study examines calculating total sediment discharge based on the Modified Einstein Procedure (MEP). A new procedure based on the Series Expansion of the Modified Einstein Procedure (SEMEP) has been developed. This procedure contains four main modifications to MEP. First, SEMEP solves the Einstein integrals quickly and accurately based on a series expansion. Next,...

  2. Multipurpose ANSYS FE procedure for welding processes simulation

    Energy Technology Data Exchange (ETDEWEB)

    Capriccioli, Andrea [ENEA CR Frascati, Via Enrico Fermi 45, 00044 Frascati (Italy); Frosi, Paolo [ENEA CR Frascati, Via Enrico Fermi 45, 00044 Frascati (Italy)], E-mail: frosi@frascati.enea.it

    2009-06-15

    ANSYS FE procedures and 3D models for thermal and mechanical simulation of both Laser and TIG welding processes are presented. The special features are the applicability to a non uniform gap and the use of a fast iterative procedure that assures the constancy of the fixed maximum temperature along the single pass and between each pass and the following, apart from their shapes and sizes. All the thermal and mechanical material properties of both INCONEL 625 and AISI 316 are described till to liquid phase; convection and radiation effects are considered. The 3D ANSYS models use both brick and non linear contact elements and elastic and elastic-plastic materials. Two full simulation are presented: a laser welding test (taken from ENEA) and a TIG welding one (source W7-X) with the root seam plus 14 passes; thermal and mechanical results are reported in the two cases and for the latter an extensive sensitivity analysis, changing mesh size of the filling material, welding speed and material properties, is explained with results and comparisons. This large sensitivity analysis has been executed for TIG welding because in this case (multi-pass welding) the reduction of CPU time is a strong requirement; but some conclusions are helpful for laser welding too. The mechanical calculation results very sensitive to the mesh shape: this fact implies very fine and regular meshes. The specimens are first restrained and then welded with the foreseen welding procedure; after that it is released and the final linear and angular shrinkages are calculated. The ANSYS birth and death procedure is used and the CPU time was strongly reduced.

  3. Multipurpose ANSYS FE procedure for welding processes simulation

    International Nuclear Information System (INIS)

    Capriccioli, Andrea; Frosi, Paolo

    2009-01-01

    ANSYS FE procedures and 3D models for thermal and mechanical simulation of both Laser and TIG welding processes are presented. The special features are the applicability to a non uniform gap and the use of a fast iterative procedure that assures the constancy of the fixed maximum temperature along the single pass and between each pass and the following, apart from their shapes and sizes. All the thermal and mechanical material properties of both INCONEL 625 and AISI 316 are described till to liquid phase; convection and radiation effects are considered. The 3D ANSYS models use both brick and non linear contact elements and elastic and elastic-plastic materials. Two full simulation are presented: a laser welding test (taken from ENEA) and a TIG welding one (source W7-X) with the root seam plus 14 passes; thermal and mechanical results are reported in the two cases and for the latter an extensive sensitivity analysis, changing mesh size of the filling material, welding speed and material properties, is explained with results and comparisons. This large sensitivity analysis has been executed for TIG welding because in this case (multi-pass welding) the reduction of CPU time is a strong requirement; but some conclusions are helpful for laser welding too. The mechanical calculation results very sensitive to the mesh shape: this fact implies very fine and regular meshes. The specimens are first restrained and then welded with the foreseen welding procedure; after that it is released and the final linear and angular shrinkages are calculated. The ANSYS birth and death procedure is used and the CPU time was strongly reduced.

  4. NK sensitivity of neuroblastoma cells determined by a highly sensitive coupled luminescent method

    International Nuclear Information System (INIS)

    Ogbomo, Henry; Hahn, Anke; Geiler, Janina; Michaelis, Martin; Doerr, Hans Wilhelm; Cinatl, Jindrich

    2006-01-01

    The measurement of natural killer (NK) cells toxicity against tumor or virus-infected cells especially in cases with small blood samples requires highly sensitive methods. Here, a coupled luminescent method (CLM) based on glyceraldehyde-3-phosphate dehydrogenase release from injured target cells was used to evaluate the cytotoxicity of interleukin-2 activated NK cells against neuroblastoma cell lines. In contrast to most other methods, CLM does not require the pretreatment of target cells with labeling substances which could be toxic or radioactive. The effective killing of tumor cells was achieved by low effector/target ratios ranging from 0.5:1 to 4:1. CLM provides highly sensitive, safe, and fast procedure for measurement of NK cell activity with small blood samples such as those obtained from pediatric patients

  5. Assessment of patients' skin dose during interventional cardiology procedures

    International Nuclear Information System (INIS)

    Tsapaki, V.; Vardalaki, E.; Kottou, S.; Molfetas, M.; Neofotistou, V.

    2002-01-01

    During the last 30 years the use of Interventional Cardiology (IC) procedures has increased significantly, mainly due to the benefits and advantages of the method that offers more accurate diagnosis and treatment along with less complications and hospitalization. However, IC procedures are based on the use of x-ray radiation, mostly localized at certain areas of patient's body and for extended periods of time. Consequently, patient may receive high radiation dose and deterministic effects, such as erythema, epilation or even dermal necrosis may be observed. Therefore, the need for reducing radiation dose is highly important. In order to achieve this, good knowledge of the dose levels delivered to the patient during IC procedures is essential since radiation effects are known to increase with dose. It is of great interest to know the point where the maximum skin dose (MSD) is noted since individual sensitivity may vary. MSDs greater than 1 Gy should be recorded. Patient dosimetry during IC procedures is a complex task since these type of procedures depend on various factors, such as complexity and severity of case, different specifications of x-ray equipment and patient's physical characteristics. Moreover, cardiologist's experience plays an important role. For these reasons, Food and Drug Administration (FDA), the International Commission on Radiological Protection (ICRP) as well as the World Health Organization (WHO), have published documents on radiation safety and ways to reduce skin injuries during IC procedures. Various methods have been proposed for measuring MSD such as the use of slow radiotherapy films, thermoluminescent detectors (TLD), scintillation detectors, Dose-Area Product (DAP) meter, as well as a combination of DAP and air kerma. A literature review on MSDs measured during IC procedures showed that doses ranged from 300 to 43000 mGy

  6. Changes of retinal light sensitivity after YAG-laser capsulotomy

    International Nuclear Information System (INIS)

    Pahor, D.; Gracner, B.

    2003-01-01

    The aim of this prospective study was to investigate the changes of retinal light sensitivity of central visual field in patients with posterior capsule opacification (PCO) after YAG-laser capsulotomy. Our study includes 18 eyes ( 18 patients) with PCO after phacoemulsification and intraocular lens implantation. In all patients YAG-laser capsulotomy was performed. In all patients, a threshold visual field analysis was carried out with the C 30-2 program of the automated Humphrey Field Analyzer before and one month after the procedure. In all patients a significant improvement of visual acuity was observed one month after capsulotomy (p 0.00004). One month after YAG-laser treatment, a significant improvement of retinal light sensitivity in the central visual field was also observed. The average MD (mean deviation) before the procedure was -6.88 db (±3.9, max. -11.7, min. 2.17) and after the procedure --4.58 db (±4.37, max. -10.87, min. +0.51). The improvement in MD was statistically significant (p = 0.00475). No correlation was established between the improvement of retinal light sensitivity and patient age or the size of capsulotomy. Our study shows that the improvement of retinal light sensitivity is significant after YAG-laser capsulotomy and does not depend on patient age or capsulotomy size. (author)

  7. Revised Unfilling Procedure for Solid Lithium Lenses

    International Nuclear Information System (INIS)

    Leveling, A.

    2003-01-01

    A procedure for unfilling used lithium lenses to has been described in Pbar Note 664. To date, the procedure has been used to disassemble lenses 20, 21, 17, 18, and 16. As a result of this work, some parts of the original procedure were found to be time consuming and ineffective. Modifications to the original procedure have been made to streamline the process and are discussed in this note. The revised procedure is included in this note.

  8. Defense Logistics: Enhanced Policy and Procedures Needed to Improve Management of Sensitive Conventional Ammunition

    Science.gov (United States)

    2016-02-01

    Information System-Retail OIS-MC Ordnance Information System-Marine Corps SAAS -MOD Standard Army Ammunition System-Modernization SRC Security Risk...automated information systems. For the Army we used LMP, SAAS , and WARS-NT; for the Navy and Marine Corps we used OIS-W, OIS-R, and OIS-MC; and for the Air...Army we used LMP, SAAS , and WARS-NT; for the Navy and Marine Corps we used OIS-W, OIS-R, and OIS-MC; and for the Air Force we used CAS. Military

  9. Global Sensitivity Analysis of Environmental Models: Convergence, Robustness and Validation

    Science.gov (United States)

    Sarrazin, Fanny; Pianosi, Francesca; Khorashadi Zadeh, Farkhondeh; Van Griensven, Ann; Wagener, Thorsten

    2015-04-01

    Global Sensitivity Analysis aims to characterize the impact that variations in model input factors (e.g. the parameters) have on the model output (e.g. simulated streamflow). In sampling-based Global Sensitivity Analysis, the sample size has to be chosen carefully in order to obtain reliable sensitivity estimates while spending computational resources efficiently. Furthermore, insensitive parameters are typically identified through the definition of a screening threshold: the theoretical value of their sensitivity index is zero but in a sampling-base framework they regularly take non-zero values. There is little guidance available for these two steps in environmental modelling though. The objective of the present study is to support modellers in making appropriate choices, regarding both sample size and screening threshold, so that a robust sensitivity analysis can be implemented. We performed sensitivity analysis for the parameters of three hydrological models with increasing level of complexity (Hymod, HBV and SWAT), and tested three widely used sensitivity analysis methods (Elementary Effect Test or method of Morris, Regional Sensitivity Analysis, and Variance-Based Sensitivity Analysis). We defined criteria based on a bootstrap approach to assess three different types of convergence: the convergence of the value of the sensitivity indices, of the ranking (the ordering among the parameters) and of the screening (the identification of the insensitive parameters). We investigated the screening threshold through the definition of a validation procedure. The results showed that full convergence of the value of the sensitivity indices is not necessarily needed to rank or to screen the model input factors. Furthermore, typical values of the sample sizes that are reported in the literature can be well below the sample sizes that actually ensure convergence of ranking and screening.

  10. Intraregional and inter-regional variability of herbicide sensitivity in common arable weed populations

    DEFF Research Database (Denmark)

    de Mol, Friederike; Gerowitt, Bärbel; Kaczmarek, Sylwia

    2015-01-01

    The question on intraregional versus inter-regional variability in herbicide sensitivity for weed populations is of major importance, both in extrapolation of model parameters and in herbicide zonal approval procedures. We hypothesised that inter-regional variability in herbicide sensitivity for ...

  11. A TOUCH-SENSITIVE DEVICE

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an optical touch-sensitive device and a method of determining a position and determining a position change of an object contacting an optical touch sensitive device. In particular, the present invention relates to an optical touch pad and a method of determining...... a position and determining a position change of an object contacting an optical touch pad. A touch-sensitive device, according to the present invention may comprise a light source, a touch- sensitive waveguide, a detector array, and a first light redirecting member, wherein at least a part of the light...... propagating towards a specific point of the detector array is prevented from being incident upon the specific point of the detector array when an object contacts a touch-sensitive surface of the touch-sensitive waveguide at a corresponding specific contact point....

  12. Efficiency of performing pulmonary procedures in a shared endoscopy unit: procedure time, turnaround time, delays, and procedure waiting time.

    Science.gov (United States)

    Verma, Akash; Lee, Mui Yok; Wang, Chunhong; Hussein, Nurmalah B M; Selvi, Kalai; Tee, Augustine

    2014-04-01

    The purpose of this study was to assess the efficiency of performing pulmonary procedures in the endoscopy unit in a large teaching hospital. A prospective study from May 20 to July 19, 2013, was designed. The main outcome measures were procedure delays and their reasons, duration of procedural steps starting from patient's arrival to endoscopy unit, turnaround time, total case durations, and procedure wait time. A total of 65 procedures were observed. The most common procedure was BAL (61%) followed by TBLB (31%). Overall procedures for 35 (53.8%) of 65 patients were delayed by ≥ 30 minutes, 21/35 (60%) because of "spillover" of the gastrointestinal and surgical cases into the time block of pulmonary procedure. Time elapsed between end of pulmonary procedure and start of the next procedure was ≥ 30 minutes in 8/51 (16%) of cases. In 18/51 (35%) patients there was no next case in the room after completion of the pulmonary procedure. The average idle time of the room after the end of pulmonary procedure and start of next case or end of shift at 5:00 PM if no next case was 58 ± 53 minutes. In 17/51 (33%) patients the room's idle time was >60 minutes. A total of 52.3% of patients had the wait time >2 days and 11% had it ≥ 6 days, reason in 15/21 (71%) being unavailability of the slot. Most pulmonary procedures were delayed due to spillover of the gastrointestinal and surgical cases into the block time allocated to pulmonary procedures. The most common reason for difficulty encountered in scheduling the pulmonary procedure was slot unavailability. This caused increased procedure waiting time. The strategies to reduce procedure delays and turnaround times, along with improved scheduling methods, may have a favorable impact on the volume of procedures performed in the unit thereby optimizing the existing resources.

  13. Analytical evaluation of actinide sensitivities

    International Nuclear Information System (INIS)

    Sola, A.

    1977-01-01

    The analytical evaluation of the sensitivities of actinides to various parameters such as cross sections, decay constants, flux and time is presented. The formulae are applied to isotopes of the Uranium, Neptunium, Plutonium and Americium series. The agreement between analytically obtained and computer evaluated sensitivities being always good, it is throught that the formulation includes all the important parameters entering in the evaluation of sensitivities. A study of the published data is made

  14. PRINCIPLES AND PROCEDURES ON FISCAL

    Directory of Open Access Journals (Sweden)

    Morar Ioan Dan

    2011-07-01

    Full Text Available Fiscal science advertise in most analytical situations, while the principles reiterated by specialists in the field in various specialized works The two components of taxation, the tax system relating to the theoretical and the practical procedures relating to tax are marked by frequent references and invocations of the underlying principles to tax. This paper attempts a return on equity fiscal general vision as a principle often invoked and used to justify tax policies, but so often violated the laws fiscality . Also want to emphasize the importance of devising procedures to ensure fiscal equitable treatment of taxpayers. Specific approach of this paper is based on the notion that tax equity is based on equality before tax and social policies of the executive that would be more effective than using the other tax instruments. I want to emphasize that if the scientific approach to justify the unequal treatment of the tax law is based on the various social problems of the taxpayers, then deviates from the issue of tax fairness justification explaining the need to promote social policies usually more attractive to taxpayers. Modern tax techniques are believed to be promoted especially in order to ensure an increasing level of high efficiency at the expense of the taxpayers obligations to ensure equality before the law tax. On the other hand, tax inequities reaction generates multiple recipients from the first budget plan, but finalities unfair measures can not quantify and no timeline for the reaction, usually not known. But while statistics show fluctuations in budgetary revenues and often find in literature reviews and analysis relevant to a connection between changes in government policies, budget execution and outcome. The effects of inequality on tax on tax procedures and budgetary revenues are difficult to quantify and is among others to this work. Providing tax equity without combining it with the principles of discrimination and neutrality

  15. Sensitivity Analysis of the Integrated Medical Model for ISS Programs

    Science.gov (United States)

    Goodenow, D. A.; Myers, J. G.; Arellano, J.; Boley, L.; Garcia, Y.; Saile, L.; Walton, M.; Kerstman, E.; Reyes, D.; Young, M.

    2016-01-01

    Sensitivity analysis estimates the relative contribution of the uncertainty in input values to the uncertainty of model outputs. Partial Rank Correlation Coefficient (PRCC) and Standardized Rank Regression Coefficient (SRRC) are methods of conducting sensitivity analysis on nonlinear simulation models like the Integrated Medical Model (IMM). The PRCC method estimates the sensitivity using partial correlation of the ranks of the generated input values to each generated output value. The partial part is so named because adjustments are made for the linear effects of all the other input values in the calculation of correlation between a particular input and each output. In SRRC, standardized regression-based coefficients measure the sensitivity of each input, adjusted for all the other inputs, on each output. Because the relative ranking of each of the inputs and outputs is used, as opposed to the values themselves, both methods accommodate the nonlinear relationship of the underlying model. As part of the IMM v4.0 validation study, simulations are available that predict 33 person-missions on ISS and 111 person-missions on STS. These simulated data predictions feed the sensitivity analysis procedures. The inputs to the sensitivity procedures include the number occurrences of each of the one hundred IMM medical conditions generated over the simulations and the associated IMM outputs: total quality time lost (QTL), number of evacuations (EVAC), and number of loss of crew lives (LOCL). The IMM team will report the results of using PRCC and SRRC on IMM v4.0 predictions of the ISS and STS missions created as part of the external validation study. Tornado plots will assist in the visualization of the condition-related input sensitivities to each of the main outcomes. The outcomes of this sensitivity analysis will drive review focus by identifying conditions where changes in uncertainty could drive changes in overall model output uncertainty. These efforts are an integral

  16. Instrument Calibration and Certification Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Davis, R. Wesley [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-05-31

    The Amptec 640SL-2 is a 4-wire Kelvin failsafe resistance meter, designed to reliably use very low-test currents for its resistance measurements. The 640SL-1 is a 2-wire version, designed to support customers using the Reynolds Industries type 311 connector. For both versions, a passive (analog) dual function DC Milliameter/Voltmeter allows the user to verify the actual 640SL output current level and the open circuit voltage on the test leads. This procedure includes tests of essential performance parameters. Any malfunction noticed during calibration, whether specifically tested for or not, shall be corrected before calibration continues or is completed.

  17. Inspection system performance test procedure

    International Nuclear Information System (INIS)

    Jensen, C.E.

    1995-01-01

    This procedure establishes requirements to administer a performance demonstration test. The test is to demonstrate that the double-shell tank inspection system (DSTIS) supplied by the contractor performs in accordance with the WHC-S-4108, Double-Shell Tank Ultrasonic Inspection Performance Specification, Rev. 2-A, January, 1995. The inspection system is intended to provide ultrasonic (UT) and visual data to determine integrity of the Westinghouse Hanford Company (WHC) site underground waste tanks. The robotic inspection system consists of the following major sub-systems (modules) and components: Mobile control center; Deployment module; Cable management assembly; Robot mechanism; Ultrasonic testing system; Visual testing system; Pneumatic system; Electrical system; and Control system

  18. Procedure for taking physical inventories

    International Nuclear Information System (INIS)

    Boston, R.A.

    1984-01-01

    Physical inventories are taken periodically to meet Company, State and IAEA requirements. Those physical inventories may be verified by IAEA and/or State inspectors. This presentation describes in an introductory but detailed manner the approaches and procedures used in planning, preparing, conducting, reconciling and reporting physical inventories for the Model Plant. Physical inventories are taken for plant accounting purposes to provide an accurate basis for starting and closing the plant material balance. Physical inventories are also taken for safeguards purposes to provide positive assurance that the nuclear materials of concern are indeed present and accounted for

  19. Capital Investment Procedures for FEMYSO

    OpenAIRE

    Oluduro, Francis Oladele; Duru, Longinus; Al Jaafar, Mofid

    2008-01-01

    Date: 2008-06-05 Level: Bachelor Thesis in Business Administration EF0703, 15 ECTS Credits. Authors: Longinus Duru (Stockholm), Francis O.Oluduro (Västerås) and Mofid Al Jaafar (Västerås) Title: Capital Investment Procedures for FEMYSO Problem Area: Undertaking an investment by FEMYSO involves weighing up the risk against the returns but still capital investment decision are still one of the most undertaken decisions by organization managers because it involves commitment of huge amount of mo...

  20. Forthcoming indefinite contract review procedure

    CERN Multimedia

    Human Resources Department

    2011-01-01

    The vacancy notices for posts opened with a view to the award of an indefinite contract will be published in early April 2011. In the meantime, the list of posts to be opened this spring is available at the following address: Indefinite contract posts - spring 2011 A second exercise will take place in autumn 2011 and, as of 2012, the indefinite contract award procedure will only be held once a year, in autumn. For more information please consult: https://hr-recruit.web.cern.ch/hr-recruit/staff/IndefiniteContracts.asp  

  1. Waste segregation procedures and benefits

    International Nuclear Information System (INIS)

    Fish, J.D.; Massey, C.D.; Ward, S.J.

    1990-01-01

    Segregation is a critical first step in handling hazardous and radioactive materials to minimize the generation of regulated wastes. In addition, segregation can significantly reduce the complexity and the total cost of managing waste. Procedures at Sandia National Laboratories, Albuquerque require that wastes be segregated, first, by waste type (acids, solvents, low level radioactive, mixed, classified, etc.). Higher level segregation requirements, currently under development, are aimed at enhancing the possibilities for recovery, recycle and reapplication; reducing waste volumes; reducing waste disposal costs, and facilitating packaging storage, shipping and disposal. 2 tabs

  2. Vasoplegic syndrome during Whipple procedure.

    Science.gov (United States)

    Anandaswamy, Tejesh C; Rajappa, Geetha C; Krishnamachar, Harish

    2017-02-01

    Vasoplegic syndrome is an unusual cause of refractory hypotension under general anesthesia. It is commonly described in the setting of cardiac surgery, but rarely seen in noncardiac setting. We describe successful management of vasoplegic syndrome during Whipple procedure with vasopressin infusion. A high index of suspicion and prompt treatment with vasopressin can be lifesaving in patients with risk factors for vasoplegic syndrome who present with severe refractory hypotension and who respond poorly to fluid administration and routine vasopressor infusion. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Entangled entanglement: A construction procedure

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Gabriele, E-mail: Gabriele.Uchida@univie.ac.at [University of Vienna, Faculty of Computer Science, Währinger Strasse 29, 1090 Vienna (Austria); Bertlmann, Reinhold A., E-mail: Reinhold.Bertlmann@univie.ac.at [University of Vienna, Faculty of Physics, Boltzmanngasse 5, 1090 Vienna (Austria); Hiesmayr, Beatrix C., E-mail: Beatrix.Hiesmayr@univie.ac.at [University of Vienna, Faculty of Physics, Boltzmanngasse 5, 1090 Vienna (Austria)

    2015-10-30

    The familiar Greenberger–Horne–Zeilinger (GHZ) states can be rewritten by entangling the Bell states for two qubits with a third qubit state, which is dubbed entangled entanglement. We show that in a constructive way we obtain all eight independent GHZ states that form the simplex of entangled entanglement, the magic simplex. The construction procedure allows a generalization to higher dimensions both, in the degrees of freedom (considering qudits) as well as in the number of particles (considering n-partite states). Such bases of GHZ-type states exhibit a cyclic geometry, a Merry Go Round, that is relevant for experimental and quantum information theoretic applications.

  4. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  5. Dye Sensitized Solar Cell, DSSC

    Directory of Open Access Journals (Sweden)

    Pongsatorn Amornpitoksuk

    2003-07-01

    Full Text Available A dye sensitized solar cell is a new type of solar cell. The operating system of this solar cell type is similar to plant’s photosynthesis process. The sensitizer is available for absorption light and transfer electrons to nanocrystalline metal oxide semiconductor. The ruthenium(II complexes with polypyridyl ligands are usually used as the sensitizers in solar cell. At the present time, the complex of [Ru(2,2',2'’-(COOH3- terpy(NCS3] is the most efficient sensitizer. The total photon to current conversion efficiency was approximately 10% at AM = 1.5.

  6. Infrared sensing based sensitive skin

    Institute of Scientific and Technical Information of China (English)

    CAO Zheng-cai; FU Yi-li; WANG Shu-guo; JIN Bao

    2006-01-01

    Developed robotics sensitive skin is a modularized, flexible, mini-type array of infrared sensors with data processing capabilities, which can be used to cover the body of a robot. Depending on the infrared sensors and periphery processing circuit, robotics sensitive skin can in real-time provide existence and distance information about obstacles for robots within sensory areas. The methodology of designing sensitive skin and the algorithm of a mass of IR data fusion are presented. The experimental results show that the multi-joint robot with this sensitive skin can work autonomously in an unknown environment.

  7. Maternal sensitivity: a concept analysis.

    Science.gov (United States)

    Shin, Hyunjeong; Park, Young-Joo; Ryu, Hosihn; Seomun, Gyeong-Ae

    2008-11-01

    The aim of this paper is to report a concept analysis of maternal sensitivity. Maternal sensitivity is a broad concept encompassing a variety of interrelated affective and behavioural caregiving attributes. It is used interchangeably with the terms maternal responsiveness or maternal competency, with no consistency of use. There is a need to clarify the concept of maternal sensitivity for research and practice. A search was performed on the CINAHL and Ovid MEDLINE databases using 'maternal sensitivity', 'maternal responsiveness' and 'sensitive mothering' as key words. The searches yielded 54 records for the years 1981-2007. Rodgers' method of evolutionary concept analysis was used to analyse the material. Four critical attributes of maternal sensitivity were identified: (a) dynamic process involving maternal abilities; (b) reciprocal give-and-take with the infant; (c) contingency on the infant's behaviour and (d) quality of maternal behaviours. Maternal identity and infant's needs and cues are antecedents for these attributes. The consequences are infant's comfort, mother-infant attachment and infant development. In addition, three positive affecting factors (social support, maternal-foetal attachment and high self-esteem) and three negative affecting factors (maternal depression, maternal stress and maternal anxiety) were identified. A clear understanding of the concept of maternal sensitivity could be useful for developing ways to enhance maternal sensitivity and to maximize the developmental potential of infants. Knowledge of the attributes of maternal sensitivity identified in this concept analysis may be helpful for constructing measuring items or dimensions.

  8. Visualization of Nonlinear Classification Models in Neuroimaging - Signed Sensitivity Maps

    DEFF Research Database (Denmark)

    Rasmussen, Peter Mondrup; Schmah, Tanya; Madsen, Kristoffer Hougaard

    2012-01-01

    Classification models are becoming increasing popular tools in the analysis of neuroimaging data sets. Besides obtaining good prediction accuracy, a competing goal is to interpret how the classifier works. From a neuroscientific perspective, we are interested in the brain pattern reflecting...... the underlying neural encoding of an experiment defining multiple brain states. In this relation there is a great desire for the researcher to generate brain maps, that highlight brain locations of importance to the classifiers decisions. Based on sensitivity analysis, we develop further procedures for model...... direction the individual locations influence the classification. We illustrate the visualization procedure on a real data from a simple functional magnetic resonance imaging experiment....

  9. Triggered by Medication Used in Dental Procedures: A Case Report

    Directory of Open Access Journals (Sweden)

    Aristo Vojdani

    2012-01-01

    Full Text Available Enhanced intestinal permeability and food sensitivity are two of the many proven causes of gastrointestinal disorders. This present report describes a woman with no previous gastrointestinal (GI complaints, who underwent dental root canal, bone graft, and implant procedures. Postsurgery she experienced an allergic reaction to the combined medications. In the weeks that followed, she presented with multiple food intolerances. Four weeks after the final dental procedure, she was assessed serologically for mucosal immune function, salivary, and blood-gluten reactivity, intestinal permeability, and other food sensitivities. Compared to her test reports from two months prior to her first dental procedure, the patient’s results showed high total secretory IgA (SIgA and elevated salivary antibodies to alpha-gliadin, indicating abnormal mucosal immunity and loss of tolerance to gluten. Her serologic assessments revealed immunoglobulin G (IgG and IgA antibodies to a range of wheat/gluten proteins and peptides, gut bacterial endotoxins and tight junction proteins. These test results indicate gut dysbiosis, enhanced intestinal permeability, systemic gluten-reactivity, and immune response to other dietary macromolecules. The present case suggests that patients who experience severe allergic or pseudoallergic reactions to medication should be assessed and monitored for gut dysfunction. If left untreated this could lead to autoimmune reactions to self tissues.

  10. Auditory phase and frequency discrimination: a comparison of nine procedures.

    Science.gov (United States)

    Creelman, C D; Macmillan, N A

    1979-02-01

    Two auditory discrimination tasks were thoroughly investigated: discrimination of frequency differences from a sinusoidal signal of 200 Hz and discrimination of differences in relative phase of mixed sinusoids of 200 Hz and 400 Hz. For each task psychometric functions were constructed for three observers, using nine different psychophysical measurement procedures. These procedures included yes-no, two-interval forced-choice, and various fixed- and variable-standard designs that investigators have used in recent years. The data showed wide ranges of apparent sensitivity. For frequency discrimination, models derived from signal detection theory for each psychophysical procedure seem to account for the performance differences. For phase discrimination the models do not account for the data. We conclude that for some discriminative continua the assumptions of signal detection theory are appropriate, and underlying sensitivity may be derived from raw data by appropriate transformations. For other continua the models of signal detection theory are probably inappropriate; we speculate that phase might be discriminable only on the basis of comparison or change and suggest some tests of our hypothesis.

  11. A general sensitivity theory for simulations of nonlinear systems

    International Nuclear Information System (INIS)

    Kenton, M.A.

    1981-01-01

    A general sensitivity theory is developed for nonlinear lumped-parameter system simulations. The point-of-departure is general perturbation theory, which has long been used for linear systems in nuclear engineering and reactor physics. The theory allows the sensitivity of particular figures-of-merit of the system behavior to be calculated with respect to any parameter.An explicit procedure is derived for applying the theory to physical systems undergoing sudden events (e.g., reactor scrams, tank ruptures). A related problem, treating figures-of-merit defined as functions of extremal values of system variables occurring at sudden events, is handled by the same procedure. The general calculational scheme for applying the theory to numerical codes is discussed. It is shown that codes which use pre-packaged implicit integration subroutines can be augmented to include sensitivity theory: a companion set of subroutines to solve the sensitivity problem is listed. This combined system analysis code is applied to a simple model for loss of post-accident heat removal in a liquid metal-cooled fast breeder reactor. The uses of the theory for answering more general sensitivity questions are discussed. One application of the theory is to systematically determine whether specific physical processes in a model contribute significantly to the figures-of-merit. Another application of the theory is for selecting parameter values which enable a model to match experimentally observed behavior

  12. Radiation risk of diagnostical procedures

    International Nuclear Information System (INIS)

    Pohlit, W.

    1986-01-01

    The environmental radiation burden of man in Germany is about 1 mGy (Milligray) per year. This is, of course, also valid for children. Due to diagnostical procedures this burden is increased to about 1.3 mGy. The question arises wether this can be neglected, or important consequences have to be drawn. To give a clear answer, the action of ionizing radiation in living cells and in organisms is explained in detail. Many of the radiation actions at the DNA can soon be repaired by the cell, if the radiation dose was small. Some damage, however will remain irreparable for the cell and consequently leads to cell death, to mutations or to cell transformation. The number of these lesion increases or decreases linearily with radiation dose. Therefore, it must be expected that the risk of tumour induction is increased to above the normal background even by the smallest doses. This small but not negligible risk has to be compared with other risks of civilization or with other medical risks. But also the benefit and the efficacy of diagnostic procedures have to be considered. (orig./HSCH) [de

  13. Procedure to describe clavicular motion.

    Science.gov (United States)

    Gutierrez Delgado, Guivey; De Beule, Matthieu; Ortega Cardentey, Dolgis R; Segers, Patrick; Iznaga Benítez, Arsenio M; Rodríguez Moliner, Tania; Verhegghe, Benedict; Palmans, Tanneke; Van Hoof, Tom; Van Tongel, Alexander

    2017-03-01

    For many years, researchers have attempted to describe shoulder motions by using different mathematical methods. The aim of this study was to describe a procedure to quantify clavicular motion. The procedure proposed for the kinematic analysis consists of 4 main processes: 3 transcortical pins in the clavicle, motion capture, obtaining 3-dimensional bone models, and data processing. Clavicular motion by abduction (30° to 150°) and flexion (55° to 165°) were characterized by an increment of retraction of 27° to 33°, elevation of 25° to 28°, and posterior rotation of 14° to 15°, respectively. In circumduction, clavicular movement described an ellipse, which was reflected by retraction and elevation. Kinematic analysis shows that the articular surfaces move by simultaneously rolling and sliding on the convex surface of the sternum for the 3 movements of abduction, flexion, and circumduction. The use of 3 body landmarks in the clavicle and the direct measurement of bone allowed description of the osteokinematic and arthrokinematic movement of the clavicle. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Geologic mapping procedure: Final draft

    International Nuclear Information System (INIS)

    1987-09-01

    Geologic mapping will provide a baseline record of the subsurface geology in the shafts and drifts of the Exploratory Shaft Facility (ESF). This information will be essential in confirming the specific repository horizon, selecting representative locations for the in situ tests, providing information for construction and decommissioning seal designs, documenting the excavation effects, and in providing information for performance assessment, which relates to the ultimate suitability of the site as a nuclear waste repository. Geologic mapping will be undertaken on the walls and roof, and locally on the floor within the completed At-Depth Facility (ADF) and on the walls of the two access shafts. Periodic mapping of the exposed face may be conducted during construction of the ADF. The mapping will be oriented toward the collection and presentation of geologic information in an engineering format and the portrayal of detailed stratigraphic information which may be useful in confirmation of drillhole data collected as part of the surface-based testing program. Geologic mapping can be considered as a predictive tool as well as a means of checking design assumptions. This document provides a description of the required procedures for geologic mapping for the ESF. Included in this procedure is information that qualified technical personnel can use to collect the required types of geologic descriptions, at the appropriate level of detail. 5 refs., 3 figs., 1 tab

  15. Surface Environmental Surveillance Procedures Manual

    International Nuclear Information System (INIS)

    Hanf, Robert W.; Poston, Ted M.

    2000-01-01

    Shows and explains certain procedures needed for surface environmental surveillance. Hanford Site environmental surveillance is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) under the Surface Environmental Surveillance Project (SESP). The basic requirements for site surveillance are set fourth in DOE Order 5400.1, General Environmental Protection Program Requirements. Guidance for the SESP is provided in DOE Order 5484.1, Environmental Protection, Safety, and Health Protection Information Reporting Requirements and DOE Order 5400.5, Radiation Protection of the Public and Environment. Guidelines for environmental surveillance activities are provided in DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance. An environmental monitoring plan for the Hanford Site is outlined in DOE/RL 91-50 Rev. 2, Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual. Personnel training requirements are documented in SESP-TP-01 Rev.2, Surface Environmental Surveillance Project Training Program.

  16. CMOS gate array characterization procedures

    Science.gov (United States)

    Spratt, James P.

    1993-09-01

    Present procedures are inadequate for characterizing the radiation hardness of gate array product lines prior to personalization because the selection of circuits to be used, from among all those available in the manufacturer's circuit library, is usually uncontrolled. (Some circuits are fundamentally more radiation resistant than others.) In such cases, differences in hardness can result between different designs of the same logic function. Hardness also varies because many gate arrays feature large custom-designed megacells (e.g., microprocessors and random access memories-MicroP's and RAM's). As a result, different product lines cannot be compared equally. A characterization strategy is needed, along with standardized test vehicle(s), methodology, and conditions, so that users can make informed judgments on which gate arrays are best suited for their needs. The program described developed preferred procedures for the radiation characterization of gate arrays, including a gate array evaluation test vehicle, featuring a canary circuit, designed to define the speed versus hardness envelope of the gate array. A multiplier was chosen for this role, and a baseline multiplier architecture is suggested that could be incorporated into an existing standard evaluation circuit chip.

  17. [Procedural learning disorder: neuropsychological characteristics].

    Science.gov (United States)

    Crespo-Eguílaz, N; Narbona, J

    This research aims at neurocognitive delineation of the core features of procedural learning disorder (PLD), otherwise labeled as motor coordination disorder or non-verbal learning disorder. A sample of 209 correlative outpatients (73% males), aged 6-12 years, all of them having QI ranging from 81 to 120, was clustered into the following neurobehavioural groups: PLD (n = 16), PLD plus attention deficit hyperactivity disorder (ADHD) (n = 37), ADHD combined type (n = 47), ADHD predominantly inattentive type (n = 23), specific language impairment (n = 68), and semantic-pragmatic language impairment (n = 18). Two additional groups of patients were included for some comparisons: children with periventricular leukomalacia (PVL) without learning disability (n = 8) or associating PLD (n = 17). A set of behavioural scales and neurocognitive tests was used to evaluate verbal and non-verbal IQ, attention, impulsivity control, visuo-motor coordination, declarative memory, procedural memory and learning, formal and functional dimensions of language, peer relationships and academic achievement. Parametric analysis were used to test the differences and similarities of neurobehavioural variables between groups. Our results allow us to conclude that PLD implies a difficult acquisition of automatized motor, cognitive and communicative abilities required in school work and peer social relationships. PLD is different from autistic spectrum disorders. It is frequently associated to inattentive ADHD. Operational criteria for diagnosis of PLD are proposed, according to our results. A bilateral posterior parietal dysfunction is a plausible explanation of its physiopathology. Preserved general intelligence and formal linguistic abilities are the clues for intervention designs.

  18. Space Stirling Cryocooler Contamination Lessons Learned and Recommended Control Procedures

    Science.gov (United States)

    Glaister, D. S.; Price, K.; Gully, W.; Castles, S.; Reilly, J.

    The most important characteristic of a space cryocooler is its reliability over a lifetime typically in excess of 7 years. While design improvements have reduced the probability of mechanical failure, the risk of internal contamination is still significant and has not been addressed in a consistent approach across the industry. A significant fraction of the endurance test and flight units have experienced some performance degradation related to internal contamination. The purpose of this paper is to describe and assess the contamination issues inside long life, space cryocoolers and to recommend procedures to minimize the probability of encountering contamination related failures and degradation. The paper covers the sources of contamination, the degradation and failure mechanisms, the theoretical and observed cryocooler sensitivity, and the recommended prevention procedures and their impact. We begin with a discussion of the contamination sources, both artificial and intrinsic. Next, the degradation and failure mechanisms are discussed in an attempt to arrive at a contaminant susceptibility, from which we can derive a contamination budget for the machine. This theoretical sensitivity is then compared with the observed sensitivity to illustrate the conservative nature of the assumed scenarios. A number of lessons learned on Raytheon, Ball, Air Force Research Laboratory, and NASA GSFC programs are shared to convey the practical aspects of the contamination problem. Then, the materials and processes required to meet the proposed budget are outlined. An attempt is made to present a survey of processes across industry.

  19. Precipitates/Salts Model Sensitivity Calculation

    International Nuclear Information System (INIS)

    Mariner, P.

    2001-01-01

    The objective and scope of this calculation is to assist Performance Assessment Operations and the Engineered Barrier System (EBS) Department in modeling the geochemical effects of evaporation on potential seepage waters within a potential repository drift. This work is developed and documented using procedure AP-3.12Q, ''Calculations'', in support of ''Technical Work Plan For Engineered Barrier System Department Modeling and Testing FY 02 Work Activities'' (BSC 2001a). The specific objective of this calculation is to examine the sensitivity and uncertainties of the Precipitates/Salts model. The Precipitates/Salts model is documented in an Analysis/Model Report (AMR), ''In-Drift Precipitates/Salts Analysis'' (BSC 2001b). The calculation in the current document examines the effects of starting water composition, mineral suppressions, and the fugacity of carbon dioxide (CO 2 ) on the chemical evolution of water in the drift

  20. Antibiotic prophylaxis in obstetric procedures.

    Science.gov (United States)

    van Schalkwyk, Julie; Van Eyk, Nancy

    2010-09-01

    To review the evidence and provide recommendations on antibiotic prophylaxis for obstetrical procedures. Outcomes evaluated include need and effectiveness of antibiotics to prevent infections in obstetrical procedures. Published literature was retrieved through searches of Medline and The Cochrane Library on the topic of antibiotic prophylaxis in obstetrical procedures. Results were restricted to systematic reviews, randomized controlled trials/controlled clinical trials, and observational studies. Searches were updated on a regular basis and articles published from January 1978 to June 2009 were incorporated in the guideline. Current guidelines published by the American College of Obstetrics and Gynecology were also incorporated. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. The evidence obtained was reviewed and evaluated by the Infectious Diseases Committee of the Society of Obstetricians and Gynaecologists of Canada under the leadership of the principal authors, and recommendations were made according to guidelines developed by the Canadian Task Force on Preventive Health Care (Table 1). Implementation of this guideline should reduce the cost and harm resulting from the administration of antibiotics when they are not required and the harm resulting from failure to administer antibiotics when they would be beneficial. SUMMARY STATEMENTS: 1. Available evidence does not support the use of prophylactic antibiotics to reduce infectious morbidity following operative vaginal delivery. (II-1) 2. There is insufficient evidence to argue for or against the use of prophylactic antibiotics to reduce infectious morbidity for manual removal of the placenta. (III) 3. There is insufficient evidence to argue for or against the use of

  1. Increasing sensitivity of MOS dosemeters in cascade connection

    International Nuclear Information System (INIS)

    Vychytil, F.; Cechak, T.; Gerndt, J.; Petr, I.

    1978-01-01

    The possibilities of increasing the sensitivity of MOS transistors in their cascade connection were studied theoretically and experimentally. The measurements confirmed the presumption that the instability of cascade-connected MOS transistors increased with the square of the number of transistors in the system. This allows systems to be formed with different sensitivity to ionizing radiation by encasing 10 to 10 4 transistors connected in cascade, which is technologically feasible. The procedure is also acceptable from the point of view of cost. (Z.M.)

  2. Thermoluminescence in fluorite: sensitization mechanism

    International Nuclear Information System (INIS)

    Cruz, M.T. da; Watanabe, S.; Mayhugh, M.R.

    1974-01-01

    The sensitization of the major glow peaks (approximately to 100 and 200 0 C) in fluorite correlates with population of traps causing higher temperature glow peaks. When considered with supralinearity results, it is concluded that either the sensitization results from an increase in trap-filling efficiencies, or the deeper traps are not filled during irradiation

  3. Netlist Oriented Sensitivity Evaluation (NOSE)

    Science.gov (United States)

    2017-03-01

    representing the official policies or endorsements, either expressed or implied, of Air Force Research Laboratory (AFRL) and the Defense Advanced Research... Heuristics for generating an alternative netlist implementation for the same logic function to achieve a better robustness measure 2...sensitivity study: 1. Tools to calculate sensitivity of netlist nodes (signals) and heuristics for generating alternative netlist implementations

  4. Sensitization to palladium in Europe

    DEFF Research Database (Denmark)

    Muris, Joris; Goossens, An; Gonçalo, Margarida

    2015-01-01

    BACKGROUND: Recently, sodium tetrachloropalladate (Na2 PdCl4 ) was found to be a more sensitive palladium patch test allergen than palladium dichloride (PdCl2 ). OBJECTIVES: To determine the optimal test concentration of Na2 PdCl4 , to evaluate the prevalence of palladium sensitization with Na2 P...... patch test concentration. Sensitization to palladium is almost as prevalent as sensitization to nickel. The sex distribution is different between nickel-sensitized and palladium-sensitized patients, suggesting different sources of exposure.......Cl4 and PdCl2 , and to compare the results with nickel sensitization in a European multicentre study. MATERIALS AND METHODS: In addition to the European or national baseline series including NiSO4 ·6H2 0 5% pet., consecutive patients were tested with PdCl2 and Na2 PdCl4 2%, 3% and 4% pet. in eight...... European dermatology clinics. The age and sex distributions were also evaluated in patients sensitized to nickel and palladium. RESULTS: In total, 1651 patients were tested. Relative to 3% Na2 PdCl4 , 4% Na2 PdCl4 did not add any information. Two per cent Na2 PdCl4 resulted in more doubtful reactions...

  5. Local Sensitivity and Diagnostic Tests

    NARCIS (Netherlands)

    Magnus, J.R.; Vasnev, A.L.

    2004-01-01

    In this paper we confront sensitivity analysis with diagnostic testing.Every model is misspecified, but a model is useful if the parameters of interest (the focus) are not sensitive to small perturbations in the underlying assumptions. The study of the e ect of these violations on the focus is

  6. Cheat Sensitive Quantum Bit Commitment

    OpenAIRE

    Hardy, Lucien; Kent, Adrian

    1999-01-01

    We define cheat sensitive cryptographic protocols between mistrustful parties as protocols which guarantee that, if either cheats, the other has some nonzero probability of detecting the cheating. We give an example of an unconditionally secure cheat sensitive non-relativistic bit commitment protocol which uses quantum information to implement a task which is classically impossible; we also describe a simple relativistic protocol.

  7. Cheat sensitive quantum bit commitment.

    Science.gov (United States)

    Hardy, Lucien; Kent, Adrian

    2004-04-16

    We define cheat sensitive cryptographic protocols between mistrustful parties as protocols which guarantee that, if either cheats, the other has some nonzero probability of detecting the cheating. We describe an unconditionally secure cheat sensitive nonrelativistic bit commitment protocol which uses quantum information to implement a task which is classically impossible; we also describe a simple relativistic protocol.

  8. Thermoluminescence in fluorite: sensitization mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, M.T. da; Watanabe, S; Mayhugh, M R

    1974-11-01

    The sensitization of the major glow peaks (approximately to 100 and 200/sup 0/ C) in fluorite correlates with population of traps causing higher temperature glow peaks. When considered with supralinearity results, it is concluded that either the sensitization results from an increase in trap-filling efficiencies, or the deeper traps are not filled during irradiation.

  9. Radiation sensitive solid state devices

    International Nuclear Information System (INIS)

    Shannon, J.M.; Ralph, J.E.

    1975-01-01

    A solid state radiation sensitive device is described employing JFETs as the sensitive elements. Two terminal construction is achieved by using a common conductor to capacitively couple to the JFET gate and to one of the source and drain connections. (auth)

  10. Time-sensitive remote sensing

    CERN Document Server

    Lippitt, Christopher; Coulter, Lloyd

    2015-01-01

    This book documents the state of the art in the use of remote sensing to address time-sensitive information requirements. Specifically, it brings together a group of authors who are both researchers and practitioners, who work toward or are currently using remote sensing to address time-sensitive information requirements with the goal of advancing the effective use of remote sensing to supply time-sensitive information. The book addresses the theoretical implications of time-sensitivity on the remote sensing process, assessments or descriptions of methods for expediting the delivery and improving the quality of information derived from remote sensing, and describes and analyzes time-sensitive remote sensing applications, with an emphasis on lessons learned. This book is intended for remote sensing scientists, practitioners (e.g., emergency responders or administrators of emergency response agencies), and students, but will also be of use to those seeking to understand the potential of remote sensing to addres...

  11. Physiotherapy following elective orthopaedic procedures.

    Science.gov (United States)

    De Kleijn, P; Blamey, G; Zourikian, N; Dalzell, R; Lobet, S

    2006-07-01

    As haemophilic arthropathy and chronic synovitis are still the most important clinical features in people with haemophilia, different kinds of invasive and orthopaedic procedures have become more common during the last decades. The availability of clotting factor has made arthroplasty of one, or even multiple joints possible. This article highlights the role of physiotherapy before and after such procedures. Synovectomies are sometimes advocated in people with haemophilia to stop repetitive cycles of intra-articular bleeds and/or chronic synovitis. The synovectomy itself, however, does not solve the muscle atrophy, loss of range of motion (ROM), instability and poor propriocepsis, often developed during many years. The key is in taking advantage of the subsequent, relatively safe, bleed-free period to address these important issues. Although the preoperative ROM is the most important variable influencing the postoperative ROM after total knee arthroplasty, there are a few key points that should be considered to improve the outcome. Early mobilization, either manual or by means of a continuous passive mobilization machine, can be an optimal solution during the very first postoperative days. Muscle isometric contractions and light open kinetic chain exercises should also be started in order to restore the quadriceps control. Partial weight bearing can be started shortly after, because of quadriceps inhibition and to avoid excessive swelling. The use of continuous clotting factor replacement permits earlier and intensive rehabilitation during the postoperative period. During the rehabilitation of shoulder arthroplasty restoring the function of the rotator cuff is of utmost importance. Often the rotator cuff muscles are inhibited in the presence of pain and loss of ROM. Physiotherapy also assists in improving pain and maintaining ROM and strength. Functional weight-bearing tasks, such as using the upper limbs to sit and stand, are often discouraged during the first 6

  12. Context awareness and sensitivity in SEA implementation

    International Nuclear Information System (INIS)

    Hilding-Rydevik, Tuija; Bjarnadottir, Holmfridur

    2007-01-01

    The Impact Assessment research community repeatedly asserts that the implementation of Strategic Environmental Assessment (SEA) should take the issue of context into consideration. The primary aim of this paper then is to attempt to give substance to the concept of 'context' in relation to the implementation of SEA. The second aim is to discuss the relevance of context consciousness and sensitivity in relation to one of the main aims given to SEA implementation i.e. to contribute to the 'integration' of environmental perspectives in planning processes. Context must be defined in relation to a certain question. In this paper the question in focus is the assumption that SEA implementation will contribute to integration of environmental issues in planning processes. Research results relating to the use of environmental tools, like for example SEA, and experiences of integration efforts, strongly indicate that the use of a single tool like SEA is not enough to achieve this integration. The current 'context free' normative and procedural assumptions concerning the aim of SEA implementation and 'best practice' in term of SEA can be criticised on the same grounds as normative and procedural planning theories, as being context free. The assumptions behind the current formulations of the aim and best practice of SEA need to be revisited. A firm empirical and theoretical knowledge and discussion is needed, especially in relation to the issue of context and integration. This paper provides a starting point in this direction

  13. Delay Discounting Rates Are Temporally Stable in an Equivalent Present Value Procedure Using Theoretical and Area under the Curve Analyses

    Science.gov (United States)

    Harrison, Justin; McKay, Ryan

    2012-01-01

    Temporal discounting rates have become a popular dependent variable in social science research. While choice procedures are commonly employed to measure discounting rates, equivalent present value (EPV) procedures may be more sensitive to experimental manipulation. However, their use has been impeded by the absence of test-retest reliability data.…

  14. Procedure for preparation of dispersions

    International Nuclear Information System (INIS)

    1978-01-01

    Procedure for the preparation of a water based dispersion of cerium oxide, characterised in that a suspension of cerium (IV) hydroxide is formed with an acid, where the acid is in the state of a disaggregation of aggregated crystalline cerium hydroxide, the suspension being preheated for a specified time and to a specified temperature, so that the pH value becomes constant, and whereby the quantity of acid in the suspension is such that the constant pH value is lower than 5.4, so that a conditioned suspension may be obtained, and water may be mixed with the conditioned suspension for making a water based dispersion of cerium oxide. (G.C.)

  15. Geometric procedures for civil engineers

    CERN Document Server

    Tonias, Elias C

    2016-01-01

    This book provides a multitude of geometric constructions usually encountered in civil engineering and surveying practice.  A detailed geometric solution is provided to each construction as well as a step-by-step set of programming instructions for incorporation into a computing system. The volume is comprised of 12 chapters and appendices that may be grouped in three major parts: the first is intended for those who love geometry for its own sake and its evolution through the ages, in general, and, more specifically, with the introduction of the computer. The second section addresses geometric features used in the book and provides support procedures used by the constructions presented. The remaining chapters and the appendices contain the various constructions. The volume is ideal for engineering practitioners in civil and construction engineering and allied areas.

  16. Radiological Work Planning and Procedures

    CERN Document Server

    Kurtz, J E

    2000-01-01

    Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In add...

  17. Procedures for maintenance and repairs

    International Nuclear Information System (INIS)

    Pickel, E.

    1981-01-01

    After a general review of the operation experience in the history of more than 12 operating years, the organization in the plant will be shown with special aspect to quality assurance, capacity of the workshops and connected groups as radiation protection, chemical laboratories etc. The number, time intervals and manpower effort for the repeating tests will be discussed. Reasons and examples for back-fitting activities in the plant are given. Besides special repair and maintenance procedures as repair of the steam generators, in-service inspection of the reactor pressure vessel, repair of a feed-water pipe and repair of the core structure in the pressure vessel, the general system to handle maintenance and repair-work in the KWO-plant will be shown. This includes also the detailed planning of the annual refueling and revision of the plant. (orig./RW)

  18. Headache following intracranial neuroendovascular procedures.

    Science.gov (United States)

    Baron, Eric P; Moskowitz, Shaye I; Tepper, Stewart J; Gupta, Rishi; Novak, Eric; Hussain, Muhammad Shazam; Stillman, Mark J

    2012-05-01

    Predicting who will develop post-procedure headache (PPH) following intracranial endovascular procedures (IEPs) would be clinically useful and potentially could assist in reducing the excessive diagnostic testing so often obtained in these patients. Although limited safety data exist, the use of triptans or dihydroergotamine (DHE) often raise concern when used with pre/post-coiled aneurysms. We sought to determine risk factors for PPH following IEP, to evaluate the utility of diagnostic testing in patients with post-coil acute headache (HA), and to record whether triptans and DHE have been used safely in this clinical setting. We conducted a retrospective chart review of adult patients undergoing IEPs. Bivariate analyses were conducted to compare patients who did and did not develop PPH. We reviewed records pertaining to 372 patients, of whom 263 underwent intracranial coil embolizations, 21 acrylic glue embolizations, and 88 stent placements. PPH occurred in 72% of coil patients, 33% of glue patients, and 14% of stent patients. Significant risk factors for post-coil HA were female gender, any pre-coil HA history, smoking, and anxiety/depression. A pre-stent history of HA exceeding 1 year's duration, and smoking were risk factors for post-stent HA. A pre-glue history of HA exceeding 1 year was the only risk factor for post-glue HA. In the small subgroup available for study, treatment with triptans or DHE was not associated with adverse events in pre/post-coiled aneurysms. Diagnostic testing was low yield. Occurrence of PPH was common after IEPs and especially so with coiling and in women, smokers, and those with anxiety/depression, and was often of longer duration than allowed by current International Classification of Headache Disorders-II criteria. The yield of diagnostic testing was low, and in a small subgroup treatment with triptans or DHE did not cause adverse events in pre/post-coiled aneurysms. Prospective studies are needed to confirm these findings.

  19. Comparing adaptive procedures for estimating the psychometric function for an auditory gap detection task.

    Science.gov (United States)

    Shen, Yi

    2013-05-01

    A subject's sensitivity to a stimulus variation can be studied by estimating the psychometric function. Generally speaking, three parameters of the psychometric function are of interest: the performance threshold, the slope of the function, and the rate at which attention lapses occur. In the present study, three psychophysical procedures were used to estimate the three-parameter psychometric function for an auditory gap detection task. These were an up-down staircase (up-down) procedure, an entropy-based Bayesian (entropy) procedure, and an updated maximum-likelihood (UML) procedure. Data collected from four young, normal-hearing listeners showed that while all three procedures provided similar estimates of the threshold parameter, the up-down procedure performed slightly better in estimating the slope and lapse rate for 200 trials of data collection. When the lapse rate was increased by mixing in random responses for the three adaptive procedures, the larger lapse rate was especially detrimental to the efficiency of the up-down procedure, and the UML procedure provided better estimates of the threshold and slope than did the other two procedures.

  20. Family presence during cardiopulmonary resuscitation and invasive procedures in children

    Directory of Open Access Journals (Sweden)

    Cristiana Araujo G. Ferreira

    2014-03-01

    Full Text Available Objective: To identify literature evidences related to actions to promote family's presence during cardiopulmonary resuscitation and invasive procedures in children hospitalized in pediatric and neonatal critical care units. Data sources : Integrative literature review in PubMed, SciELO and Lilacs databases, from 2002 to 2012, with the following inclusion criteria: research article in Medicine, or Nursing, published in Portuguese, English or Spanish, using the keywords "family", "invasive procedures", "cardiopulmonary resuscitation", "health staff", and "Pediatrics". Articles that did not refer to the presence of the family in cardiopulmonary resuscitation and invasive procedures were excluded. Therefore, 15 articles were analyzed. Data synthesis : Most articles were published in the United States (80%, in Medicine and Nursing (46%, and were surveys (72% with healthcare team members (67% as participants. From the critical analysis, four themes related to the actions to promote family's presence in invasive procedures and cardiopulmonary resuscitation were obtained: a to develop a sensitizing program for healthcare team; b to educate the healthcare team to include the family in these circumstances; c to develop a written institutional policy; d to ensure the attendance of family's needs. Conclusions: Researches on these issues must be encouraged in order to help healthcare team to modify their practice, implementing the principles of the Patient and Family Centered Care model, especially during critical episodes.

  1. Long terms results of Draf 3 procedure

    NARCIS (Netherlands)

    Georgalas, C.; Hansen, F.; Videler, W. J. M.; Fokkens, W. J.

    2011-01-01

    To assess the effectiveness and factors associated with restenosis after Draf type III (Endoscopic Modified Lothrop) frontal sinus drainage procedure. Retrospective analysis of prospectively collected data. A hundred and twenty two consecutive patients undergoing Draf III procedure for recalcitrant

  2. Procedure Integrated Development Environment (PRIDE), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA captures and distributes operational knowledge in the form of procedures. These procedures are created and accessed by a range of people performing many...

  3. Procedures For Microbial-Ecology Laboratory

    Science.gov (United States)

    Huff, Timothy L.

    1993-01-01

    Microbial Ecology Laboratory Procedures Manual provides concise and well-defined instructions on routine technical procedures to be followed in microbiological laboratory to ensure safety, analytical control, and validity of results.

  4. Typical NRC inspection procedures for model plant

    International Nuclear Information System (INIS)

    Blaylock, J.

    1984-01-01

    A summary of NRC inspection procedures for a model LEU fuel fabrication plant is presented. Procedures and methods for combining inventory data, seals, measurement techniques, and statistical analysis are emphasized

  5. TMACS Test Procedure TP011: Panalarm Interface

    International Nuclear Information System (INIS)

    Seghers, R.; Washburn, S.J.

    1994-01-01

    The TMACS Software Test Procedures translate the project's acceptance criteria into test steps. The TMACS Test Plan (WHC-SD-WM-TP-148) is fulfilled when all Test Cases are approved. This Test Procedure tests the TMACS Panalarm Interface functions

  6. Heuristic procedures for transmission planning in competitive electricity markets

    International Nuclear Information System (INIS)

    Lu, Wene; Bompard, Ettore; Napoli, Roberto; Jiang, Xiuchen

    2007-01-01

    The network structure of the power system, in an electricity market under the pool model, may have severe impacts on market performance, reducing market efficiency considerably, especially when producers bid strategically. In this context network re-enforcement plays a major role and proper strategies of transmission planning need to be devised. This paper presents, for pool-model electricity markets, two heuristic procedures to select the most effective subset of lines that would reduce the impacts on the market, from a set of predefined candidate lines and within the allowed budget for network expansion. A set of indices that account for the economic impacts of the re-enforcing of the candidate lines, both in terms of construction cost and market efficiency, are proposed and used as sensitivity indices in the heuristic procedure. The proposed methods are applied and compared with reference to an 18-bus test system. (author)

  7. Emotion Monitoring – Verification of Physiological Characteristics Measurement Procedures

    Directory of Open Access Journals (Sweden)

    Landowska Agnieszka

    2014-12-01

    Full Text Available This paper concerns measurement procedures on an emotion monitoring stand designed for tracking human emotions in the Human-Computer Interaction with physiological characteristics. The paper addresses the key problem of physiological measurements being disturbed by a motion typical for human-computer interaction such as keyboard typing or mouse movements. An original experiment is described, that aimed at practical evaluation of measurement procedures performed at the emotion monitoring stand constructed at GUT. Different locations of sensors were considered and evaluated for suitability and measurement precision in the Human- Computer Interaction monitoring. Alternative locations (ear lobes and forearms for skin conductance, blood volume pulse and temperature sensors were proposed and verified. Alternative locations proved correlation with traditional locations as well as lower sensitiveness to movements like typing or mouse moving, therefore they can make a better solution for monitoring the Human-Computer Interaction.

  8. Sensitization development in austenitic stainless steel piping

    International Nuclear Information System (INIS)

    Bruemmer, S.M.; Page, R.E.; Atteridge, D.G.

    1984-10-01

    Pacific Northwest Laboratory and the Division of Engineering Technology of the US Nuclear Regulatory Commission are conducting a program to determine a method for evaluating welded and rapair-welded stainless steel piping for light-water reactor service. Validated models, based on experimental data, are being developed to predict the degree of sensitization (DOS) and the intergranular stress corrosion cracking (IGSCC) susceptibility in the heat-affected zone (HAZ) of the SS weldments. The cumulative effects of material composition, past fabrication procedures, past service exposure, weldment thermomechanical (TM) history, and projected post-repair component life are being considered. This program will measure and model the development of HAZ TM history and resultant sensitized microstructure in welded and repair-welded piping. An empirical correlation between a material's DOS and its susceptibility to SCC will be determined using slow strain rate tensile tests. Mill heat chemistries and processing/fabrication records already required in the nuclear industry will be used as input for initial DOS predictions

  9. Polarization sensitive optical coherence tomography in dentistry

    International Nuclear Information System (INIS)

    Dichtl, S.

    1998-01-01

    Optical coherence tomography (OCT) is a noninvasive and noncontact technique for obtaining cross-sectional images of biologic structure, which was initially introduced to depict the transparent tissue of the eye. It employs the partial coherence properties of a light source to image structures with high resolution (< 20 (m). Recently, this technique has also been applied in turbid media. This tomographic imaging is analogous to conventional ultrasound B mode imaging, except that OCT measures the intensity of backreflected infrared light rather than acoustical waves. First applications, of OCT in dentistry for diagnosing periodontal disease have been reported by Colston et al. presenting in vitro OCT images of the dental and periodontal tissues of porcine premolar teeth. In this work, the feasibility of polarisation sensitive OCT for dental material is suggested. In contrast with conventional OCT, where the magnitude of backscattered light as a function of depth is imaged, backscattered light is used to image the magnitude of the birefringence in the sample as a function of depth. Partial loss of birefringence is known to be an early indication of incipient caries or tissue thermal damage. Applying this technique for caries diagnosis or guidance regarding optimal dosimetry for thermally mediated laser therapeutic procedures, polarisation sensitive OCT would represent a promising new technology for dentistry. (author)

  10. XML Syntax for Clinical Laboratory Procedure Manuals

    OpenAIRE

    Saadawi, Gilan; Harrison, James H.

    2003-01-01

    We have developed a document type description (DTD) in Extensable Markup Language (XML)1 for clinical laboratory procedures. Our XML syntax can adequately structure a variety of procedure types across different laboratories and is compatible with current procedure standards. The combination of this format with an XML content management system and appropriate style sheets will allow efficient procedure maintenance, distributed access, customized display and effective searching across a large b...

  11. The new numbers contrast sensitivity chart for contrast sensitivity measurement

    Directory of Open Access Journals (Sweden)

    Bharkbhum Khambhiphant

    2011-10-01

    Conclusions: These charts show reasonable agreement and can be used interchangeably with the MARS. It is helpful for Thai people who can only read numbers in doing the test. We can use them in routinely contrast sensitivity measurement.

  12. Environmental Sensitivity in Children: Development of the Highly Sensitive Child Scale and Identification of Sensitivity Groups

    Science.gov (United States)

    Pluess, Michael; Assary, Elham; Lionetti, Francesca; Lester, Kathryn J.; Krapohl, Eva; Aron, Elaine N.; Aron, Arthur

    2018-01-01

    A large number of studies document that children differ in the degree they are shaped by their developmental context with some being more sensitive to environmental influences than others. Multiple theories suggest that "Environmental Sensitivity" is a common trait predicting the response to negative as well as positive exposures.…

  13. Dual Globalizations and Intercultural Sensitivities

    Directory of Open Access Journals (Sweden)

    Saeid Reza Ameli

    2009-08-01

    Full Text Available This article aimed to investigate the intercultural sensitivities between Sunnite Turkmen groups and Shiite groups in Golestan province of Iran through considering the most important factors influenced it. The intercultural development inventory (IDI, which designed according to Milton Bennet's the intercultural sensitivities theory, was utilised to examine the intercultural sensitivities between those Muslim groups. The intercultural sensitivities theory essentially states that the more communication among people leads them to have the less intercultural sensitivities. In other words, the development of communications among people causes to diminish their intercultural sensitivities. In this study, both virtual and actual measurement domains were used in order to measure the communications development of two groups. The development of virtual communications was measured according people's interactivity with different types of media, especially Satellite and Internet, whereas the actual one was measured based on three cities varying according to different religious distribution. Finally this article concluded that the development of virtual and actual communications led to decreasing intercultural sensitivities among people in this area.

  14. Dye Sensitizers for Photodynamic Therapy

    Directory of Open Access Journals (Sweden)

    Harold S. Freeman

    2013-03-01

    Full Text Available Photofrin® was first approved in the 1990s as a sensitizer for use in treating cancer via photodynamic therapy (PDT. Since then a wide variety of dye sensitizers have been developed and a few have been approved for PDT treatment of skin and organ cancers and skin diseases such as acne vulgaris. Porphyrinoid derivatives and precursors have been the most successful in producing requisite singlet oxygen, with Photofrin® still remaining the most efficient sensitizer (quantum yield = 0.89 and having broad food and drug administration (FDA approval for treatment of multiple cancer types. Other porphyrinoid compounds that have received approval from US FDA and regulatory authorities in other countries include benzoporphyrin derivative monoacid ring A (BPD-MA, meta-tetra(hydroxyphenylchlorin (m-THPC, N-aspartyl chlorin e6 (NPe6, and precursors to endogenous protoporphyrin IX (PpIX: 1,5-aminolevulinic acid (ALA, methyl aminolevulinate (MAL, hexaminolevulinate (HAL. Although no non-porphyrin sensitizer has been approved for PDT applications, a small number of anthraquinone, phenothiazine, xanthene, cyanine, and curcuminoid sensitizers are under consideration and some are being evaluated in clinical trials. This review focuses on the nature of PDT, dye sensitizers that have been approved for use in PDT, and compounds that have entered or completed clinical trials as PDT sensitizers.

  15. Procedural Attack! Procedural Generation for Populated Virtual Cities: A Survey

    Directory of Open Access Journals (Sweden)

    Werner Gaisbauer

    2017-06-01

    Full Text Available On the one hand, creating rich virtual worlds "by hand" like in the game Grand Theft Auto V is hugely expensive and limited to large studios. On the other hand, procedural content generation (PCG allows tiny teams to create huge worlds like Hello Games did with only four people (in the beginning for the recently released game No Man's Sky. Following in the footsteps of Hello Games, this paper tries to equip the reader with an overview about the state-of-the-art of how to build such a virtual world, i.e., a populated virtual city with buildings, streets, parks, vegetation, humans, and vehicles, using just PCG assets. Each PCG asset that is envisioned to bring the city to life is grouped and discussed in detail and the latest research trends in PCG are presented together with open questions. Using the above-mentioned PCG assets, instead of months, a city can be built in a mere couple of minutes by a user without much experience in designing 3D assets. The city can then be used for many applications like games, virtual reality (VR, or film.

  16. New procedures to evaluate visually lossless compression for display systems

    Science.gov (United States)

    Stolitzka, Dale F.; Schelkens, Peter; Bruylants, Tim

    2017-09-01

    Visually lossless image coding in isochronous display streaming or plesiochronous networks reduces link complexity and power consumption and increases available link bandwidth. A new set of codecs developed within the last four years promise a new level of coding quality, but require new techniques that are sufficiently sensitive to the small artifacts or color variations induced by this new breed of codecs. This paper begins with a summary of the new ISO/IEC 29170-2, a procedure for evaluation of lossless coding and reports the new work by JPEG to extend the procedure in two important ways, for HDR content and for evaluating the differences between still images, panning images and image sequences. ISO/IEC 29170-2 relies on processing test images through a well-defined process chain for subjective, forced-choice psychophysical experiments. The procedure sets an acceptable quality level equal to one just noticeable difference. Traditional image and video coding evaluation techniques, such as, those used for television evaluation have not proven sufficiently sensitive to the small artifacts that may be induced by this breed of codecs. In 2015, JPEG received new requirements to expand evaluation of visually lossless coding for high dynamic range images, slowly moving images, i.e., panning, and image sequences. These requirements are the basis for new amendments of the ISO/IEC 29170-2 procedures described in this paper. These amendments promise to be highly useful for the new content in television and cinema mezzanine networks. The amendments passed the final ballot in April 2017 and are on track to be published in 2018.

  17. 40 CFR 791.30 - Hearing procedures.

    Science.gov (United States)

    2010-07-01

    ... officer may deem necessary to an understanding and determination of the dispute. The hearing officer shall... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Hearing procedures. 791.30 Section 791... (CONTINUED) DATA REIMBURSEMENT Hearing Procedures § 791.30 Hearing procedures. (a) Representation by counsel...

  18. 49 CFR 195.214 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding procedures. 195.214 Section 195.214... PIPELINE Construction § 195.214 Welding procedures. (a) Welding must be performed by a qualified welder in accordance with welding procedures qualified under Section 5 of API 1104 or Section IX of the ASME Boiler and...

  19. 46 CFR 154.665 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Welding procedures. 154.665 Section 154.665 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS... Construction § 154.665 Welding procedures. Welding procedure tests for cargo tanks for a design temperature...

  20. 49 CFR 192.225 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding procedures. 192.225 Section 192.225... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.225 Welding procedures. (a) Welding must be performed by a qualified welder in accordance with welding procedures...

  1. 40 CFR 1065.10 - Other procedures.

    Science.gov (United States)

    2010-07-01

    ... importance of pursuing changes to the procedures: (i) Whether supplemental emission standards or other... procedures, such as those of the California Air Resources Board or the International Organization for... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Other procedures. 1065.10 Section 1065...

  2. TMACS Test Procedure TP009: Acromag Driver

    International Nuclear Information System (INIS)

    Washburn, S.J.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS Acromag Software Driver (Bridge Code)

  3. Environmental Measurements Laboratory (EML) procedures manual

    International Nuclear Information System (INIS)

    Chieco, N.A.; Bogen, D.C.; Knutson, E.O.

    1990-11-01

    Volume 1 of this manual documents the procedures and existing technology that are currently used by the Environmental Measurements Laboratory. A section devoted to quality assurance has been included. These procedures have been updated and revised and new procedures have been added. They include: sampling; radiation measurements; analytical chemistry; radionuclide data; special facilities; and specifications. 228 refs., 62 figs., 37 tabs. (FL)

  4. 39 CFR 5.2 - Committee procedure.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Committee procedure. 5.2 Section 5.2 Postal Service UNITED STATES POSTAL SERVICE THE BOARD OF GOVERNORS OF THE U.S. POSTAL SERVICE COMMITTEES (ARTICLE V) § 5.2 Committee procedure. Each committee establishes its own rules of procedure, consistent with...

  5. WSSDA's Guide to Parliamentary Procedures. Revised

    Science.gov (United States)

    Randolph, Mary

    2004-01-01

    This guide to parliamentary procedures is presented by the Washington State School Directors' Association (WSSDA) for use by local school boards within the State of Washington. Parliamentary law and parliamentary procedure is the key to order and to provide justice and fairness to all. Through both formal and informal parliamentary procedures,…

  6. Intake Procedures in College Counseling Centers.

    Science.gov (United States)

    Pappas, James P.; And Others

    Intake procedures is the common subject of four papers presented in this booklet. James P. Pappas discusses trends, a decision theory model, information and issues in his article "Intake Procedures in Counseling Centers--Trends and Theory." In the second article "The Utilization of Standardized Tests in Intake Procedures or 'Where's the Post…

  7. Objective Truth Institution in Criminal Procedure

    Directory of Open Access Journals (Sweden)

    Voltornist O. A.

    2012-11-01

    Full Text Available The article deals with the category of objective truth in criminal procedure, its importance for correct determination of criminal court procedure aims. The author analyzes also the bill draft offered by the RF Committee of Inquiry “On amending in the RF Criminal Procedure Code due to the implementation ofobjective truth institution in criminal procedure”

  8. TMACS Test Procedure TP007: System administration

    International Nuclear Information System (INIS)

    Scanlan, P.; Washburn, S.; Seghers, R.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS System Administration functions

  9. MITS Feed and Withdrawal Subsystem: operating procedures

    International Nuclear Information System (INIS)

    Brown, W.S.

    1980-01-01

    This document details procedures for the operation of the MITS (Machine Interface Test System) Feed and Withdrawal Subsystem (F and W). Included are fill with UF 6 , establishment of recycle and thruput flows, shutdown, UF 6 makeup, dump to supply container, Cascade dump to F and W, and lights cold trap dump, all normal procedures, plus an alternate procedure for trapping light gases

  10. 32 CFR 635.35 - Procedures.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Procedures. 635.35 Section 635.35 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS LAW ENFORCEMENT REPORTING Victim and Witness Assistance Procedures § 635.35 Procedures. (a) As required by Federal law, Army personnel...

  11. 21 CFR 211.150 - Distribution procedures.

    Science.gov (United States)

    2010-04-01

    ...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Holding and Distribution § 211.150 Distribution procedures. Written procedures shall be established, and followed, describing the... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Distribution procedures. 211.150 Section 211.150...

  12. 40 CFR 205.54 - Test procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test procedures. 205.54 Section 205.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54 Test procedures. The procedures described...

  13. TMACS Test Procedure TP002: Trending

    International Nuclear Information System (INIS)

    Scanlan, P.K.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS Trending functions

  14. 28 CFR 79.73 - Appeals procedures.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Appeals procedures. 79.73 Section 79.73 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) CLAIMS UNDER THE RADIATION EXPOSURE COMPENSATION ACT Procedures § 79.73 Appeals procedures. (a) An appeal must be in writing and must be received by...

  15. Film dosimetry for IMRT: sensitivity corrections

    International Nuclear Information System (INIS)

    Suchowerska, N.; Hoban, P.; Davison, A.; Metcalfe, P.

    2000-01-01

    Full text: The trend towards conformal, dynamic and intensity modulated radiotherapy treatments has furthered the need for true integrating dosimetry. In traditional radiotherapy, film dosimetry is commonly used. The accuracy and reproducibility of film optical density as an indicator of dose, has been associated with several variables. These include the effects of film specific sensitivity, direction of exposure, chemical processing and film scanner sensitivity. In this study, a procedure is developed to account for these variables, with a particular view to film being used as a dosimeter for conformal treatments. An effective sensitometric curve was established by exposing part of a single sheet of film to known doses. All films were processed together and scanned using a DuoscanT1200 transmission scanner, resulting in 12 bit image files. The images were analysed using Osiris software and the results fitted to the modified Williamson equation: P P s (l - 10 αD ) This yields values of α [film sensitivity], and P s [saturation pixel value], allowing individual dosimetry films to be normalised to this sensitometric calibration curve. For validation, a piece of Kodak X Omat-V film was sealed in a head phantom and exposed to a total of 51 IMRT fields, delivered from 6 gantry angles. The rest of the sheet of film was resealed and exposed to four known doses, providing sensitometric data, specific to this exposure. All films were then processed, scanned and analysed as described above. Observed variations in serial films exposed to 50cGy is in the order of 9% [mean 25.0,standard deviation = 3.2]. The automatic gain of the scanner system typically contributed 4% variation and needs to be carefully monitored. Results indicate that by using the sensitometric data from each exposure, the collective errors can be minimised. The IMRT exposure results confirm that the above process is viable for use in dosimetry for conformal radiation therapy. Copyright (2000) Australasian

  16. Sensitive Interviewing in Qualitative Research.

    Science.gov (United States)

    Dempsey, Laura; Dowling, Maura; Larkin, Philip; Murphy, Kathy

    2016-12-01

    In this paper we focus on important considerations when planning and conducting qualitative interviews on sensitive topics. Drawing on experiences of conducting interviews with dementia caregivers, a framework of essential elements in qualitative interviewing was developed to emphasize study participants' needs while also providing guidance for researchers. Starting with a definition of sensitive research, the framework includes preparing for interviews, interacting with gatekeepers of vulnerable groups, planning for interview timing, and location, building relationships and conducting therapeutic interactions, protecting ethically vulnerable participants, and planning for disengagement. This framework has the potential to improve the effectiveness of sensitive interviewing with vulnerable groups. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Thickly Syndetical Sensitivity of Topological Dynamical System

    Directory of Open Access Journals (Sweden)

    Heng Liu

    2014-01-01

    Full Text Available Consider the surjective continuous map f:X→X, where X is a compact metric space. In this paper we give several stronger versions of sensitivity, such as thick sensitivity, syndetic sensitivity, thickly syndetic sensitivity, and strong sensitivity. We establish the following. (1 If (X,f is minimal and sensitive, then (X,f is syndetically sensitive. (2 Weak mixing implies thick sensitivity. (3 If (X,f is minimal and weakly mixing, then it is thickly syndetically sensitive. (4 If (X,f is a nonminimal M-system, then it is thickly syndetically sensitive. Devaney chaos implies thickly periodic sensitivity. (5 We give a syndetically sensitive system which is not thickly sensitive. (6 We give thickly syndetically sensitive examples but not cofinitely sensitive ones.

  18. Modified Arthroscopic Brostrom Procedure With Bone Tunnels.

    Science.gov (United States)

    Lui, Tun Hing

    2016-08-01

    The open anatomic repair of the anterior talofibular and calcaneofibular ligaments (modified Brostrom procedure) is widely accepted as the standard surgical stabilization procedure for lateral ankle instability that does not respond to conservative measures. Arthroscopic Brostrom procedures with a suture anchor have been reported to achieve both anatomic repair of the lateral ankle ligaments and management of the associated intra-articular lesions. However, the complication rates are higher than open Brostom procedures. Many of these complications are associated with the use of a suture anchor. We report a modified arthroscopic Brostrom procedure in which the anterolateral ankle capsule is anchored to the lateral malleolus through small bone tunnels instead of suture anchors.

  19. Standard practice for detection sensitivity mapping of In-Plant Walk-through metal detectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This standard practice covers a procedure for determining the weakest detection path through the portal aperture and the worst-case orthogonal orientation of metallic test objects. It results in detection sensitivity maps, which model the detection zone in terms related to detection sensitivity and identify the weakest detection paths. Detection sensitivity maps support sensitivity adjustment and performance evaluation procedures (see Practices C1269 and C1309). Note 1—Unsymmetrical metal objects possessing a primary longitudinal component, such as handguns and knives, usually have one particular orientation that produces the weakest detection signal. The orientation and the path through the detector aperture where the weakest response is produced may not be the same for all test objects, even those with very similar appearance. Note 2—In the case of multiple specified test objects or for test objects that are orientation sensitive, it may be necessary to map each object several times to determine ...

  20. High order depletion sensitivity analysis

    International Nuclear Information System (INIS)

    Naguib, K.; Adib, M.; Morcos, H.N.

    2002-01-01

    A high order depletion sensitivity method was applied to calculate the sensitivities of build-up of actinides in the irradiated fuel due to cross-section uncertainties. An iteration method based on Taylor series expansion was applied to construct stationary principle, from which all orders of perturbations were calculated. The irradiated EK-10 and MTR-20 fuels at their maximum burn-up of 25% and 65% respectively were considered for sensitivity analysis. The results of calculation show that, in case of EK-10 fuel (low burn-up), the first order sensitivity was found to be enough to perform an accuracy of 1%. While in case of MTR-20 (high burn-up) the fifth order was found to provide 3% accuracy. A computer code SENS was developed to provide the required calculations

  1. A procedure for estimation of pipe break probabilities due to IGSCC

    International Nuclear Information System (INIS)

    Bergman, M.; Brickstad, B.; Nilsson, F.

    1998-06-01

    A procedure has been developed for estimation of the failure probability of welds joints in nuclear piping susceptible to intergranular stress corrosion cracking. The procedure aims at a robust and rapid estimate of the failure probability for a specific weld with known stress state. Random properties are taken into account of the crack initiation rate, the initial crack length, the in-service inspection efficiency and the leak rate. A computer realization of the procedure has been developed for user friendly applications by design engineers. Some examples are considered to investigate the sensitivity of the failure probability to different input quantities. (au)

  2. Measuring sensitivity in pharmacoeconomic studies. Refining point sensitivity and range sensitivity by incorporating probability distributions.

    Science.gov (United States)

    Nuijten, M J

    1999-07-01

    The aim of the present study is to describe a refinement of a previously presented method, based on the concept of point sensitivity, to deal with uncertainty in economic studies. The original method was refined by the incorporation of probability distributions which allow a more accurate assessment of the level of uncertainty in the model. In addition, a bootstrap method was used to create a probability distribution for a fixed input variable based on a limited number of data points. The original method was limited in that the sensitivity measurement was based on a uniform distribution of the variables and that the overall sensitivity measure was based on a subjectively chosen range which excludes the impact of values outside the range on the overall sensitivity. The concepts of the refined method were illustrated using a Markov model of depression. The application of the refined method substantially changed the ranking of the most sensitive variables compared with the original method. The response rate became the most sensitive variable instead of the 'per diem' for hospitalisation. The refinement of the original method yields sensitivity outcomes, which greater reflect the real uncertainty in economic studies.

  3. Micromycetes sensitiveness to heavy metals

    OpenAIRE

    O. N. Korinovskaya; V. N. Gryshko

    2011-01-01

    The sensitivity of 33 micromycete species to nitric compounds of copper, lead, zinc, nickel and cadmium has been determined. Absidia butleri Lendn, Mortierella vanesae Dixon-Stewart, Cunninghamella echinulata Thaxte, Curvularia tuberculata Jain, Cladosporium cladosporiodes (Fresen) G. A. de Vries and Fusarium solani (C. Mart.) Appel et Wollenw are sensitive to minimal content of the heavy metals (0.75 of maximum permissible concentration (MPC)) in the growth medium. At the same time Trixoderm...

  4. Photogrammetry procedures applied to anthropometry.

    Science.gov (United States)

    Okimoto, Maria Lúcialeite Ribeiro; Klein, Alison Alfred

    2012-01-01

    This study aims to evaluate the reliability and establish procedures for the use of digital photogrammetry in anthropometric measurements of the human hand. The methodology included the construction of a platform to allow the placement of the hand always equivalent to a distance of the camera lens and to annul the effects of parallax. We developed a software to perform the measurements from the images and built up a subject of proof in a cast from a negative mold, this object was subjected to measurements with digital photogrammetry using the data collection platform in caliper and the Coordinate Measuring Machine (MMC). The results of the application of photogrammetry in the data collection segment hand, allow us to conclude that photogrammetry is an effective presenting precision coefficient below 0.940. Within normal and acceptable values, given the magnitude of the data used in anthropometry. It was concluded photogrammetry then be reliable, accurate and efficient for carrying out anthropometric surveys of population, and presents less difficulty to collect in-place.

  5. Training review criteria and procedures

    International Nuclear Information System (INIS)

    1986-07-01

    The industry, through commitment to the INPO-managed Training Accreditation Program, is implementing what is referred to as performance-based training, or the Systems Approach to Training (SAT). The NRC considers the following five elements as essential to these training programs: Systematic analysis of the jobs to be performed; learning objectives that are derived from the analysis and that describe desired performance after training; Training design and implementation based on the learning objectives; Evaluation of trainee mastery of the objectives during training; and evaluation and revision of the training based on the performance of trained personnel in the job setting. As indicated in the ''Commission Policy Statement on Training and Qualifications of Nuclear Power Plant Personnel'' of March 20, 1985,''the NRC will continue to closely monitor the process [INPO Accreditation] and its results, and ''It remains the continuing responsibility of the NRC to independently evaluate applicants' and licensees' implementation of improvement programs....'' These procedures provide a systematic means for implementing two of the NRC monitoring functions identified in the Commission Policy Statement: ''Continuing evaluation of industry training and qualification program effectiveness,''; and ''Monitoring plant and industry trends and events involving personnel errors.''

  6. Radiological Work Planning and Procedures

    International Nuclear Information System (INIS)

    KURTZ, J.E.

    2000-01-01

    Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In addition, there seems to be confusion as to what should be and what should not be included in the TWD

  7. Imaging of cartilage repair procedures

    International Nuclear Information System (INIS)

    Sanghvi, Darshana; Munshi, Mihir; Pardiwala, Dinshaw

    2014-01-01

    The rationale for cartilage repair is to prevent precocious osteoarthritis in untreated focal cartilage injuries in the young and middle-aged population. The gamut of surgical techniques, normal postoperative radiological appearances, and possible complications have been described. An objective method of recording the quality of repair tissue is with the magnetic resonance observation of cartilage repair tissue (MOCART) score. This scoring system evaluates nine parameters that include the extent of defect filling, border zone integration, signal intensity, quality of structure and surface, subchondral bone, subchondral lamina, and records presence or absence of synovitis and adhesions. The five common techniques of cartilage repair currently offered include bone marrow stimulation (microfracture or drilling), mosaicplasty, synthetic resorbable scaffold grafts, osteochondral allograft transplants, and autologous chondrocyte implantation (ACI). Complications of cartilage repair procedures that may be demonstrated on magnetic resonance imaging (MRI) include plug loosening, graft protuberance, graft depression, and collapse in mosaicplasty, graft hypertrophy in ACI, and immune response leading to graft rejection, which is more common with synthetic grafts and cadaveric allografts

  8. Remote handling procedures in JET

    International Nuclear Information System (INIS)

    Raimondi, T.; Huguet, M.

    1976-01-01

    Remote maintenance will be needed in the second phase of operation due to the structural activation produced by deuterium-tritium discharges. Priority will be given to tasks which require frequent intervention, but efforts will be made also to tackle larger operations such as replacement of an octant. Owing to the variety and unpredictability of the operations which may be required, general purpose telemanipulator and TV systems will be used, mounted on versatile articulated supports capable of reaching the various parts of the machine. An experimental programme is planned to test the envisaged equipment and develop procedures for carrying out the various tasks as they are more clearly identified. Design of peripheral equipment for easy accessibility, choice of simple connection methods, development of auxiliary tools, as well as careful programming of the operations, will be essential for successful remote maintenance. The effort put into these areas will, however, also result in considerable time saving during the assembly and maintenance in non-active conditions. Preliminary feasibility tests of some difficult operations have already been done with a force-reflecting servo-manipulator and two TV sets for front and side viewing. Leak identification and precision welding for vacuum tightness were demonstrated

  9. Probabilistic safety analysis procedures guide

    International Nuclear Information System (INIS)

    Papazoglou, I.A.; Bari, R.A.; Buslik, A.J.

    1984-01-01

    A procedures guide for the performance of probabilistic safety assessment has been prepared for interim use in the Nuclear Regulatory Commission programs. The probabilistic safety assessment studies performed are intended to produce probabilistic predictive models that can be used and extended by the utilities and by NRC to sharpen the focus of inquiries into a range of tissues affecting reactor safety. This guide addresses the determination of the probability (per year) of core damage resulting from accident initiators internal to the plant and from loss of offsite electric power. The scope includes analyses of problem-solving (cognitive) human errors, a determination of importance of the various core damage accident sequences, and an explicit treatment and display of uncertainties for the key accident sequences. Ultimately, the guide will be augmented to include the plant-specific analysis of in-plant processes (i.e., containment performance) and the risk associated with external accident initiators, as consensus is developed regarding suitable methodologies in these areas. This guide provides the structure of a probabilistic safety study to be performed, and indicates what products of the study are essential for regulatory decision making. Methodology is treated in the guide only to the extent necessary to indicate the range of methods which is acceptable; ample reference is given to alternative methodologies which may be utilized in the performance of the study

  10. Crisis management and warning procedures

    Directory of Open Access Journals (Sweden)

    Valérie November

    2009-03-01

    territoriale du risque s’avère nécessaire.Based on two flood events that recently affected new housing areas in very different political, organisational and hydrological contexts, this article examines the practices of actors involved in emergency and crisis situations in Switzerland. In both cases, the actors are identified – through their role and their position in the various procedures related to crisis management – and an inventory is made of the documents used. The study examines how the flood events were managed, identifies the organisational changes that followed the crises, and determines how the risk was conceived and to what extent it was formalised by the different actors both before and after the floods. Finally new forecasting and warning procedures that were set up following the events are described. The study shows that floods have a decisive impact on the production of knowledge, but that this phenomenon varies according to the actors. Events such as floods also sometimes reveal the existence of "latent" knowledge, or knowledge that is available but has not yet been integrated into institutional procedures. In terms of both forecasting and crisis management, these events also provide the opportunity to test information channels and to identify and correct any problems relating to organisation, cooperation or the reliability of means of communication. Among other things, the risks and crises related to flooding modify the dynamics and policies of the local area as a result of readjustments in the networks of actors. The introduction of emergency and crisis management measures appears more effective, however, than the reorganisation of planning and development procedures, a process which generally takes a lot longer. Nevertheless, since the recollection of events tends to fade with time, it is important that risks find a more concrete form of spatial expression on the landscape.

  11. DACS upgrade acceptance test procedure

    International Nuclear Information System (INIS)

    Zuehlke, A.C.

    1994-01-01

    The readiness of the Data Acquisition and Control System (DACS) to provide monitoring and control of the mixer pump, directional drive system, and the instrumentation associated with the SY-101 tank and support systems, and the proper functioning of the DACS with new Model 984-785 Programmable Logic Controllers (PLCs), new MODBUS PLUS version 2.01 software for the PLCs, and version 3.72 of the GENESIS software will be systematically evaluated by performance of this procedure. The DACS, which is housed in a trailer located just outside of the north fence at the SY tank farm, receives input signals from a variety of sensors located in and around the SY-101 tanks. These sensors provide information such as: tank vapor space and ventilation system H 2 concentration; tank waste temperature; tank pressure; waste density; operating pump parameters such as speed, flow, rotational position, discharge pressure, and internal temperature; strain (for major equipment); and waste level. The output of these sensors is conditioned and transmitted to the DACS computers where these signals are displayed, recorded, and monitored for out-of-specification conditions. If abnormal conditions are detected, then, in certain situations, the DACS automatically generates alarms and causes the system to abort pump operations

  12. Developing, adopting and adapting operating procedures

    International Nuclear Information System (INIS)

    Rabouhams, J.

    1986-01-01

    This lecture specifies all the dispositions which have been taken by EDF Nuclear and Fossil Generation Department - according to the fact that availability and safety largely depend on the quality of the procedures and their easy handling - in order to develop, adopt and adapt the operating procedures. The following points are treated: General organization of procedures for plant operation during normal and abnormal conditions; Personnel and extend of responsibility involved into the development of procedures (research center, training center, specialized services, nuclear station, etc.); Validation of the procedures by means of full-scope simulators; Modifications of the procedures taking into account operation experience in material and human fields; Development of simulation softs in order to perform the procedures in abnormal situations; Evolution of operating technics and future skills. (orig.)

  13. Surgeon-patient communication during awake procedures.

    Science.gov (United States)

    Smith, Claire S; Guyton, Kristina; Pariser, Joseph J; Siegler, Mark; Schindler, Nancy; Langerman, Alexander

    2017-06-01

    Surgeons are increasingly performing procedures on awake patients. Communication during such procedures is complex and underexplored in the literature. Surgeons were recruited from the faculty of 2 hospitals to participate in an interview regarding their approaches to communication during awake procedures. Three researchers used the constant comparative method to transcribe, code, and review interviews until saturation was reached. Twenty-three surgeons described the advantages and disadvantages of awake procedures, their communication with the awake patient, their interactions with staff and with trainees, the environment of awake procedures, and how communication in this context is taught and learned. Surgeons recognized communication during awake procedures as important and reported varied strategies for ensuring patient comfort in this context. However, they also acknowledged challenges with multiparty communication during awake procedures, especially in balancing commitments to teaching with their duty to comfort the patient. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Human Reliability Analysis For Computerized Procedures

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Gertman, David I.; Le Blanc, Katya

    2011-01-01

    This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

  15. Multiple position borehole extensometer procedure: Final draft

    International Nuclear Information System (INIS)

    1986-08-01

    The purpose of the Multiple Position Borehole Extensometer Procedure is to provide detailed information for MPBXs installed at the salt Deaf Smith County ESF. This procedure includes design of equipment, installation, instructions, instrument locations, measurement requirements, support requirements, quality assurance procedures, and data acquisition requirements. Data reduction procedures are also discussed; however, the relevance of the data is discussed elsewhere in the appropriate test plans. Sufficient detail is provided in this procedure to allow for integrating the requirements of this procedure into both the facility construction and overall underground testing programs; identifying necessary equipment for procurement; determining data acquisition requirements as input to Automatic Data Acquisition System (ADAS) design; providing step-by-step procedures for training personnel as well as for directing field operations; establishing quality assurance (QA) checkpoints and implementation methods; and defining data reduction methods and providing the anticipated accuracy of the system. 11 refs., 14 figs

  16. Writer`s guide for technical procedures

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    A primary objective of operations conducted in the US Department of Energy (DOE) complex is safety. Procedures are a critical element of maintaining a safety envelope to ensure safe facility operation. This DOE Writer`s Guide for Technical Procedures addresses the content, format, and style of technical procedures that prescribe production, operation of equipment and facilities, and maintenance activities. The DOE Writer`s Guide for Management Control Procedures and DOE Writer`s Guide for Emergency and Alarm Response Procedures are being developed to assist writers in developing nontechnical procedures. DOE is providing this guide to assist writers across the DOE complex in producing accurate, complete, and usable procedures that promote safe and efficient operations that comply with DOE orders, including DOE Order 5480.19, Conduct of Operations for DOE Facilities, and 5480.6, Safety of Department of Energy-Owned Nuclear Reactors.

  17. ADGEN: a system for automated sensitivity analysis of predictive models

    International Nuclear Information System (INIS)

    Pin, F.G.; Horwedel, J.E.; Oblow, E.M.; Lucius, J.L.

    1987-01-01

    A system that can automatically enhance computer codes with a sensitivity calculation capability is presented. With this new system, named ADGEN, rapid and cost-effective calculation of sensitivities can be performed in any FORTRAN code for all input data or parameters. The resulting sensitivities can be used in performance assessment studies related to licensing or interactions with the public to systematically and quantitatively prove the relative importance of each of the system parameters in calculating the final performance results. A general procedure calling for the systematic use of sensitivities in assessment studies is presented. The procedure can be used in modeling and model validation studies to avoid over modeling, in site characterization planning to avoid over collection of data, and in performance assessments to determine the uncertainties on the final calculated results. The added capability to formally perform the inverse problem, i.e., to determine the input data or parameters on which to focus to determine the input data or parameters on which to focus additional research or analysis effort in order to improve the uncertainty of the final results, is also discussed. 7 references, 2 figures

  18. ADGEN: a system for automated sensitivity analysis of predictive models

    International Nuclear Information System (INIS)

    Pin, F.G.; Horwedel, J.E.; Oblow, E.M.; Lucius, J.L.

    1986-09-01

    A system that can automatically enhance computer codes with a sensitivity calculation capability is presented. With this new system, named ADGEN, rapid and cost-effective calculation of sensitivities can be performed in any FORTRAN code for all input data or parameters. The resulting sensitivities can be used in performance assessment studies related to licensing or interactions with the public to systematically and quantitatively prove the relative importance of each of the system parameters in calculating the final performance results. A general procedure calling for the systematic use of sensitivities in assessment studies is presented. The procedure can be used in modelling and model validation studies to avoid ''over modelling,'' in site characterization planning to avoid ''over collection of data,'' and in performance assessment to determine the uncertainties on the final calculated results. The added capability to formally perform the inverse problem, i.e., to determine the input data or parameters on which to focus additional research or analysis effort in order to improve the uncertainty of the final results, is also discussed

  19. Sensitivity analysis of EQ3

    International Nuclear Information System (INIS)

    Horwedel, J.E.; Wright, R.Q.; Maerker, R.E.

    1990-01-01

    A sensitivity analysis of EQ3, a computer code which has been proposed to be used as one link in the overall performance assessment of a national high-level waste repository, has been performed. EQ3 is a geochemical modeling code used to calculate the speciation of a water and its saturation state with respect to mineral phases. The model chosen for the sensitivity analysis is one which is used as a test problem in the documentation of the EQ3 code. Sensitivities are calculated using both the CHAIN and ADGEN options of the GRESS code compiled under G-float FORTRAN on the VAX/VMS and verified by perturbation runs. The analyses were performed with a preliminary Version 1.0 of GRESS which contains several new algorithms that significantly improve the application of ADGEN. Use of ADGEN automates the implementation of the well-known adjoint technique for the efficient calculation of sensitivities of a given response to all the input data. Application of ADGEN to EQ3 results in the calculation of sensitivities of a particular response to 31,000 input parameters in a run time of only 27 times that of the original model. Moreover, calculation of the sensitivities for each additional response increases this factor by only 2.5 percent. This compares very favorably with a running-time factor of 31,000 if direct perturbation runs were used instead. 6 refs., 8 tabs

  20. Limit of sensitivity of low-background counting equipment

    International Nuclear Information System (INIS)

    Homann, S.G.

    1991-01-01

    The Hazards Control Department's Radiological Measurements Laboratory (RML) analyzes many types of sample media in support of the Laboratory's health and safety program. The Department has determined that the equation for the minimum limit of sensitivity, MDC(α,β) = 2.71 + 3.29 (r b t s ) 1/2 is also adequate for RML counting systems with very-low-background levels. This paper reviews the normal distribution case and address the special case of determining the limit of sensitivity of a counting system when the background count rate is well known and small. In the latter case, we must use an exact test procedure based on the binomial distribution. However, the error in using the normal distribution for calculating a detection system's limit of sensitivity is not significant even as the total observed number of counts approaches or equals zero. 2 refs., 4 figs

  1. Sensitivity of wildlife habitat models to uncertainties in GIS data

    Science.gov (United States)

    Stoms, David M.; Davis, Frank W.; Cogan, Christopher B.

    1992-01-01

    Decision makers need to know the reliability of output products from GIS analysis. For many GIS applications, it is not possible to compare these products to an independent measure of 'truth'. Sensitivity analysis offers an alternative means of estimating reliability. In this paper, we present a CIS-based statistical procedure for estimating the sensitivity of wildlife habitat models to uncertainties in input data and model assumptions. The approach is demonstrated in an analysis of habitat associations derived from a GIS database for the endangered California condor. Alternative data sets were generated to compare results over a reasonable range of assumptions about several sources of uncertainty. Sensitivity analysis indicated that condor habitat associations are relatively robust, and the results have increased our confidence in our initial findings. Uncertainties and methods described in the paper have general relevance for many GIS applications.

  2. Linear Array Ultrasonic Transducers: Sensitivity and Resolution Study

    International Nuclear Information System (INIS)

    Kramb, V.A.

    2005-01-01

    The University of Dayton Research Institute (UDRI) under contract by the US Air Force has designed and integrated a fully automated inspection system for the inspection of turbine engines that incorporates linear phased array ultrasonic transducers. Phased array transducers have been successfully implemented into weld and turbine blade root inspections where the defect types are well known and characterized. Embedded defects in aerospace turbine engine components are less well defined, however. In order to determine the applicability of linear arrays to aerospace inspections the sensitivity of array transducers to embedded defects in engine materials must be characterized. In addition, the implementation of array transducers into legacy inspection procedures must take into account any differences in sensitivity between the array transducer and that of the single element transducer currently used. This paper discusses preliminary results in a study that compares the sensitivity of linear array and conventional single element transducers to synthetic hard alpha defects in a titanium alloy

  3. INITIATION AND CONDUCT OF ADMINISTRATIVE PROCEDURE

    Directory of Open Access Journals (Sweden)

    Milan Stipic

    2013-12-01

    Full Text Available General administrative procedure act contains legal norms that are valid for all identical cases. In addition to the general, there are special administrative procedures, customized to the specific administrative areas. Procedure initiation is regulated. Administrative procedure can be initiated at the request of the proponent and ex officio. When the official determines that the conditions for the conduct of administrative procedure are met, before making a decision, all the facts and circumstances relevant to the resolution of administrative matter have to be identified. When there are no legal requirements for the initiation of procedures, the official shall make a decision to reject the application of the party. The procedure is initiated ex officio when stipulated by law or when protection of public interest requires it. When initiating procedure ex officio, the public authority shall take into consideration the petition or other information that indicate the need to protect the public interest. In such cases the applicant is not a party, and the official is obliged to notify the applicant, if initiation of procedures is not accepted ex officio. Based on the notification, the applicant has a right to complain, including the situation when there is no response within the prescribed period of 30 days. Public authority may, therefore it is not obliged to, initiate administrative procedure by public announcement only in a situation where the parties are unknown, while it is obliged to initiate procedure by public announcement when this method of initiating the procedure is prescribed by law. Initiation of procedure with public announcement occurs in rare cases. Due to the application of efficiency and cost-effectiveness principle, two or more administrative procedures can be merged into one procedure by a conclusion. The condition for this is that the rights or obligations of the parties are based on the same legal basis and on the same or

  4. Prenatal diagnosis--principles of diagnostic procedures and genetic counseling.

    Directory of Open Access Journals (Sweden)

    Ryszard Slezak

    2008-04-01

    Full Text Available The frequency of inherited malformations as well as genetic disorders in newborns account for around 3-5%. These frequency is much higher in early stages of pregnancy, because serious malformations and genetic disorders usually lead to spontaneous abortion. Prenatal diagnosis allowed identification of malformations and/or some genetic syndromes in fetuses during the first trimester of pregnancy. Thereafter, taking into account the severity of the disorders the decision should be taken in regard of subsequent course of the pregnancy taking into account a possibilities of treatment, parent's acceptation of a handicapped child but also, in some cases the possibility of termination of the pregnancy. In prenatal testing, both screening and diagnostic procedures are included. Screening procedures such as first and second trimester biochemical and/or ultrasound screening, first trimester combined ultrasound/biochemical screening and integrated screening should be widely offered to pregnant women. However, interpretation of screening results requires awareness of both sensitivity and predictive value of these procedures. In prenatal diagnosis ultrasound/MRI searching as well as genetic procedures are offered to pregnant women. A variety of approaches for genetic prenatal analyses are now available, including preimplantation diagnosis, chorion villi sampling, amniocentesis, fetal blood sampling as well as promising experimental procedures (e.g. fetal cell and DNA isolation from maternal blood. An incredible progress in genetic methods opened new possibilities for valuable genetic diagnosis. Although karyotyping is widely accepted as golden standard, the discussion is ongoing throughout Europe concerning shifting to new genetic techniques which allow obtaining rapid results in prenatal diagnosis of aneuploidy (e.g. RAPID-FISH, MLPA, quantitative PCR.

  5. The mediation procedure in Romania

    Directory of Open Access Journals (Sweden)

    Alexandrina Zaharia

    2009-06-01

    Full Text Available The mediation activity as an alternative way of solving conflicts occupies an important place in modernsociety. Currently, the mediation reached its maturity worldwide being adopted without reservations.The future of solving conflicts is undoubtedly closely related to mediation. XXth century is the century of solvingconflicts amiably outside the court room. In Romania and the mediation profession were regulated by the Law no.192/2006, on the basis of the idea that mediation is one of the major themes of the reform strategy of the judicialsystem 2005-2007. By adopting the mentioned law it was followed the idea of reducing the volume of activitycourts, and therefore, relieve them of as many cases, with the direct effect on the quality of justice. Mediation is avoluntary process in which the parties with a neutral and impartial third party, without power of decision - themediator - who is qualified to assist the parties to negotiate, facilitating the communication between them andhelping them to reach a unanimous effective and sustainable agreement. The parties may resort to mediation beforeor after triggering a trial. Mediation can be applied, in principle, on any type of conflict. However, theRomanian legislator has established special stipulations on conflict mediation in criminal, civil and familylaw. Although not expressly provided, the stipulations regarding the civil conflicts and also apply to commercialconflicts. Therefore, the mediation is applicable to most types of lawsuits, except those relating to personalrights. As a "win- win" principle, the mediation does not convert any of the parties defeated or victorious; allthose involved have gained by applying this procedure.

  6. Vaginal hysterectomy, an outpatient procedure.

    Science.gov (United States)

    Engh, Marie Ellström; Hauso, Wenche

    2012-11-01

    To report our experience of treating women undergoing vaginal hysterectomy in an outpatient setting and to identify risk factors for hospital admission and women dissatisfied with care. Prospective observational report. department of obstetrics and gynecology, university hospital in Norway. 150 women who underwent vaginal hysterectomy at the outpatient clinic from February 2009 to April 2010. Perioperative data were collected prospectively and case notes were searched for complications. On the first postoperative day all women were contacted by telephone by a nurse. A visual analogue scale (VAS) was used to monitor pain and nausea during the stay at the outpatient clinic and the day after surgery. VAS was also used to specify the women's degree of satisfaction with care the day after surgery. The number of women who could be discharged from the outpatient unit and had a satisfaction score of ≥7 the day after surgery. Of the 150 women, 84% could be discharged after a mean observation period of 276 min (SD ± 80 min). The mean satisfaction score was 9.0, SD ± 1.4, and 92.6% of the women reported ≥7 points in the satisfaction score. No women with serious complications were sent home. Using a multivariable logistic regression model only pain at discharge was found as significant (p= 0.009) for admittance to hospital. Vaginal hysterectomy is a feasible outpatient procedure and the majority of women were satisfied with the care they received. © 2012 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2012 Nordic Federation of Societies of Obstetrics and Gynecology.

  7. Dependencies of the radiation sensitivity of human tooth enamel in EPR dosimetry

    International Nuclear Information System (INIS)

    Wieser, A.; El-Faramawy, N.; Meckbach, R.

    2001-01-01

    The EPR dose response of tooth enamel was determined for human molars collected in Egypt. The influence of age, gender and residence of the tooth donors as well as tooth position and sample preparation on EPR sensitivity and its variability over the enamel samples was investigated. The EPR sensitivity and its variability were found to depend only on the sample preparation procedure. The variability in EPR sensitivity of enamel from Egyptian teeth was maximally 10% and the mean sensitivity was in good agreement with that of German teeth

  8. Serine Protease Zymography: Low-Cost, Rapid, and Highly Sensitive RAMA Casein Zymography.

    Science.gov (United States)

    Yasumitsu, Hidetaro

    2017-01-01

    To detect serine protease activity by zymography, casein and CBB stain have been used as a substrate and a detection procedure, respectively. Casein zymography has been using substrate concentration at 1 mg/mL and employing conventional CBB stain. Although ordinary casein zymography provides reproducible results, it has several disadvantages including time-consuming and relative low sensitivity. Improved casein zymography, RAMA casein zymography, is rapid and highly sensitive. RAMA casein zymography completes the detection process within 1 h after incubation and increases the sensitivity at least by tenfold. In addition to serine protease, the method also detects metalloprotease 7 (MMP7, Matrilysin) with high sensitivity.

  9. Dye-sensitized solar cells based on purple corn sensitizers

    Science.gov (United States)

    Phinjaturus, Kawin; Maiaugree, Wasan; Suriharn, Bhalang; Pimanpaeng, Samuk; Amornkitbamrung, Vittaya; Swatsitang, Ekaphan

    2016-09-01

    Natural dye extracted from husk, cob and silk of purple corn, were used for the first time as photosensitizers in dye sensitized solar cells (DSSCs). The dye sensitized solar cells fabrication process has been optimized in terms of solvent extraction. The resulting maximal efficiency of 1.06% was obtained from purple corn husk extracted by acetone. The ultraviolet-visible (UV-vis) spectroscopy, Fourier transform infrared spectroscopy (FTIR), electrochemical impedance spectroscopy (EIS) and incident photon-to-current efficiency (IPCE) were employed to characterize the natural dye and the DSSCs.

  10. Role of microextraction sampling procedures in forensic toxicology.

    Science.gov (United States)

    Barroso, Mário; Moreno, Ivo; da Fonseca, Beatriz; Queiroz, João António; Gallardo, Eugenia

    2012-07-01

    The last two decades have provided analysts with more sensitive technology, enabling scientists from all analytical fields to see what they were not able to see just a few years ago. This increased sensitivity has allowed drug detection at very low concentrations and testing in unconventional samples (e.g., hair, oral fluid and sweat), where despite having low analyte concentrations has also led to a reduction in sample size. Along with this reduction, and as a result of the use of excessive amounts of potentially toxic organic solvents (with the subsequent environmental pollution and costs associated with their proper disposal), there has been a growing tendency to use miniaturized sampling techniques. Those sampling procedures allow reducing organic solvent consumption to a minimum and at the same time provide a rapid, simple and cost-effective approach. In addition, it is possible to get at least some degree of automation when using these techniques, which will enhance sample throughput. Those miniaturized sample preparation techniques may be roughly categorized in solid-phase and liquid-phase microextraction, depending on the nature of the analyte. This paper reviews recently published literature on the use of microextraction sampling procedures, with a special focus on the field of forensic toxicology.

  11. Sentinel lymph node procedure is highly accurate in squamous cell carcinoma of the vulva

    NARCIS (Netherlands)

    de Hullu, JA; Hollema, H; Piers, DA; Verheijen, RHM; van Diest, PJ; Mourits, MJE; Aalders, JG; van der Zee, AGJ

    Purpose: To determine the diagnostic accuracy of the sentinel lymph node procedure in patients with squamous cell carcinoma of the vulva and to investigate whether step sectioning and immunohistochemistry of sentinel lymph nodes increase the sensitivity for detection of metastases. Patients and

  12. PC based temporary shielding administrative procedure (TSAP)

    International Nuclear Information System (INIS)

    Olsen, D.E.; Pederson, G.E.; Hamby, P.N.

    1995-01-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison's six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met

  13. PC based temporary shielding administrative procedure (TSAP)

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, D.E.; Pederson, G.E. [Sargent & Lundy, Chicago, IL (United States); Hamby, P.N. [Commonwealth Edison Co., Downers Grove, IL (United States)

    1995-03-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison`s six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met.

  14. Global optimization and sensitivity analysis

    International Nuclear Information System (INIS)

    Cacuci, D.G.

    1990-01-01

    A new direction for the analysis of nonlinear models of nuclear systems is suggested to overcome fundamental limitations of sensitivity analysis and optimization methods currently prevalent in nuclear engineering usage. This direction is toward a global analysis of the behavior of the respective system as its design parameters are allowed to vary over their respective design ranges. Presented is a methodology for global analysis that unifies and extends the current scopes of sensitivity analysis and optimization by identifying all the critical points (maxima, minima) and solution bifurcation points together with corresponding sensitivities at any design point of interest. The potential applicability of this methodology is illustrated with test problems involving multiple critical points and bifurcations and comprising both equality and inequality constraints

  15. Selective sensitivity in Kerr microscopy.

    Science.gov (United States)

    Soldatov, I V; Schäfer, R

    2017-07-01

    A new technique for contrast separation in wide-field magneto-optical Kerr microscopy is introduced. Utilizing the light from eight light emitting diodes, guided to the microscope by glass fibers and being switched synchronously with the camera exposure, domain images with orthogonal in-plane sensitivity can be displayed simultaneously at real-time, and images with pure in-plane or polar contrast can be obtained. The benefit of this new method of contrast separation is demonstrated for Permalloy films, a NdFeB sinter magnet, and a cobalt crystal. Moreover, the new technique is shown to strongly enhance the sensitivity of Kerr microscopy by eliminating parasitic contrast contributions occurring in conventional setups. A doubling of the in-plane domain contrast and a sensitivity to Kerr rotations as low as 0.6 mdeg is demonstrated.

  16. Phase-sensitive flow cytometer

    Energy Technology Data Exchange (ETDEWEB)

    Steinkamp, J.A.

    1992-12-31

    This report describes phase-sensitive flow cytometer (FCM) which provides additional FCM capability to use the fluorescence lifetime of one or more fluorochromes bound to single cells to provide additional information regarding the cells. The resulting fluorescence emission can be resolved into individual fluorescence signals if two fluorochromes are present or can be converted directly to a decay lifetime from a single fluorochrome. The excitation light for the fluorochromes is modulated to produce an amplitude modulated fluorescence pulse as the fluorochrome is excited in the FCM. The modulation signal also forms a reference signal that is phase-shifted a selected amount for subsequent mixing with the output modulated fluorescence intensity signal in phase-sensitive detection circuitry. The output from the phase-sensitive circuitry is then an individual resolved fluorochrome signal or a single fluorochrome decay lifetime, depending on the applied phase shifts.

  17. Selective sensitivity in Kerr microscopy

    Science.gov (United States)

    Soldatov, I. V.; Schäfer, R.

    2017-07-01

    A new technique for contrast separation in wide-field magneto-optical Kerr microscopy is introduced. Utilizing the light from eight light emitting diodes, guided to the microscope by glass fibers and being switched synchronously with the camera exposure, domain images with orthogonal in-plane sensitivity can be displayed simultaneously at real-time, and images with pure in-plane or polar contrast can be obtained. The benefit of this new method of contrast separation is demonstrated for Permalloy films, a NdFeB sinter magnet, and a cobalt crystal. Moreover, the new technique is shown to strongly enhance the sensitivity of Kerr microscopy by eliminating parasitic contrast contributions occurring in conventional setups. A doubling of the in-plane domain contrast and a sensitivity to Kerr rotations as low as 0.6 mdeg is demonstrated.

  18. Uncertainty and Sensitivity Analyses Plan

    International Nuclear Information System (INIS)

    Simpson, J.C.; Ramsdell, J.V. Jr.

    1993-04-01

    Hanford Environmental Dose Reconstruction (HEDR) Project staff are developing mathematical models to be used to estimate the radiation dose that individuals may have received as a result of emissions since 1944 from the US Department of Energy's (DOE) Hanford Site near Richland, Washington. An uncertainty and sensitivity analyses plan is essential to understand and interpret the predictions from these mathematical models. This is especially true in the case of the HEDR models where the values of many parameters are unknown. This plan gives a thorough documentation of the uncertainty and hierarchical sensitivity analysis methods recommended for use on all HEDR mathematical models. The documentation includes both technical definitions and examples. In addition, an extensive demonstration of the uncertainty and sensitivity analysis process is provided using actual results from the Hanford Environmental Dose Reconstruction Integrated Codes (HEDRIC). This demonstration shows how the approaches used in the recommended plan can be adapted for all dose predictions in the HEDR Project

  19. complexes as sensitizers for dye sensitized solar cells

    Indian Academy of Sciences (India)

    Compared to N719, H112 sensitizer showed enhanced molar extinction coefficient and relatively better monochromatic incident photon-to-current conversion efficiency (IPCE) across the spectral range of 400 to 800 nm with solar energy-to-electrical conversion efficiency () of 2.43% [open circuit photovoltage (VOC) ...

  20. Lessening Sensitivity: Student Experiences of Teaching and Learning Sensitive Issues

    Science.gov (United States)

    Lowe, Pam

    2015-01-01

    Despite growing interest in learning and teaching as emotional activities, there is still very little research on experiences of sensitive issues. Using qualitative data from students from a range of social science disciplines, this study investigates student's experiences. The paper highlights how, although they found it difficult and distressing…