WorldWideScience

Sample records for sendanryoku futan wariai

  1. Leveling of battery load and extension of battery life by serial connection of electric double layer capacitors with batteries for electric vehicles. Experimental results on the small model; Denki jidoshayo denchi to denki nijuso capacitor no chokuretsu setsuzoku ni yoru denchi futan no heijunka oyobi denchijumyo no enshinka. (kogata model ni yoru jikken seika). Kogata model ni yoru jikken seika

    Energy Technology Data Exchange (ETDEWEB)

    Takehara, J.; Okubo, N.; Miyaoka, K. [Chugoku Electric Power Co. Inc., Hiroshima (Japan)

    1996-10-25

    The load leveling method of batteries for electric vehicles was studied for extension of a battery life and mileage every charging. Under large load fluctuation conditions such as deceleration and acceleration, use of electric power sources other than battery for peek load at acceleration can improve a battery life, output power capacity and mileage every charging. Combination of effective recovery of regenerative power at deceleration with its discharge at acceleration is one of the effective methods. The electric double layer capacitors are serially connected with the batteries, regenerative power is charged only into the capacitors, and both voltages of the battery and capacitor are applied to a power circuit. Battery load is reduced by load on the capacitor. Until the capacitor is re-charged by regenerative power after full discharge, power is supplied only by battery through a diode. Capacitor power is used as effectively as possible until approaching considerably low voltage. As peak load of the battery is reduced by 30%, the mileage increases by 5.7%, and the battery cycle life becomes 1.5 times longer. 7 refs., 5 figs., 3 tabs.