WorldWideScience

Sample records for semi-supine human body

  1. A study of semi-rigid support on ankle supination sprain kinematics.

    Science.gov (United States)

    Tang, Y M; Wu, Z H; Liao, W H; Chan, K M

    2010-12-01

    Ankle sprain injury is very common in sports and the use of ankle support is crucial. This research investigated the effect of an ankle brace in reducing the ankle angular displacement and angular velocity during sudden supination. In the experiment, 11 healthy males were tested. The bracing condition, semi-rigid ankle braces were investigated. The angular displacement and angular velocity of the ankle were computed. The motion-capture system was adopted to capture the three-dimensional coordinates of the reflective markers. The coordinates of the reflective markers were used to compute the ankle kinematics during simulated ankle supination. A mechanical supination platform was used to simulate the sprain motions. Experimental results showed that the semi-rigid brace tested significantly reduced the ankle angular displacement and angular velocity compared with control conditions during sudden supination. In conclusion, the semi-rigid-type brace can provide significant restriction to reduce the magnitudes of the angular displacement and angular velocity of the ankle during sudden supination sprain. The semi-rigid-type brace is suggested as the prophylactic bracing for the ankle. © 2009 John Wiley & Sons A/S.

  2. Finite element modeling for predicting the contact pressure between a foam mattress and the human body in a supine position.

    Science.gov (United States)

    Lee, Wookjin; Won, Byeong Hee; Cho, Seong Wook

    2017-01-01

    In this paper, we generated finite element (FE) models to predict the contact pressure between a foam mattress and the human body in a supine position. Twenty-year-old males were used for three-dimensional scanning to produce the FE human models, which was composed of skin and muscle tissue. A linear elastic isotropic material model was used for the skin, and the Mooney-Rivlin model was used for the muscle tissue because it can effectively represent the nonlinear behavior of muscle. The contact pressure between the human model and the mattress was predicted by numerical simulation. The human models were validated by comparing the body pressure distribution obtained from the same human subject when he was lying on two different mattress types. The experimental results showed that the slope of the lower part of the mattress caused a decrease in the contact pressure at the heels, and the effect of bone structure was most pronounced in the scapula. After inserting a simple structure to function as the scapula, the contact pressure predicted by the FE human models was consistent with the experimental body pressure distribution for all body parts. These results suggest that the models proposed in this paper will be useful to researchers and designers of products related to the prevention of pressure ulcers.

  3. Peridural anesthesia and the distribution of blood in supine humans

    International Nuclear Information System (INIS)

    Arndt, J.O.; Hoeck, A.S.; Stanton-Hicks, M.; Stuehmeier, K.D.

    1985-01-01

    To determine the effects of vasomotor tone on intrathoracic and splanchnic blood volume, the distribution of radioactively (/sup 99m/Tc) labeled erythrocytes was recorded by whole body scintigraphy before and during peridural anesthesia (PDA) in eight supine men. The radioactivity was recorded with a gamma camera and its distribution determined in the thorax, abdomen, and limbs. Arterial and central venous pressure, heart rate, and calf volume and flow also were measured. During PDA with a sensory block up to T4/5, radioactivity increased only in the denervated legs, whereas it decreased in all other regions, i.e., in the thorax, the innervated upper limbs, and in the splanchnic vasculature. However, in two of the subjects, after an initial decrease, splanchnic blood content increased while intrathoracic blood volume decreased further. The effects of PDA on thoracic and splanchnic filling could be duplicated by the sequestration of about 500-600 ml of blood in both legs. In supine humans high peridural anesthesia evokes the same decrease in intrathoracic blood volume as orthostasis. Potential circulatory collapse may ensue when the vasoconstrictor response fails in the splanchnic circulation

  4. Human semi-supervised learning.

    Science.gov (United States)

    Gibson, Bryan R; Rogers, Timothy T; Zhu, Xiaojin

    2013-01-01

    Most empirical work in human categorization has studied learning in either fully supervised or fully unsupervised scenarios. Most real-world learning scenarios, however, are semi-supervised: Learners receive a great deal of unlabeled information from the world, coupled with occasional experiences in which items are directly labeled by a knowledgeable source. A large body of work in machine learning has investigated how learning can exploit both labeled and unlabeled data provided to a learner. Using equivalences between models found in human categorization and machine learning research, we explain how these semi-supervised techniques can be applied to human learning. A series of experiments are described which show that semi-supervised learning models prove useful for explaining human behavior when exposed to both labeled and unlabeled data. We then discuss some machine learning models that do not have familiar human categorization counterparts. Finally, we discuss some challenges yet to be addressed in the use of semi-supervised models for modeling human categorization. Copyright © 2013 Cognitive Science Society, Inc.

  5. Semi-recumbent position versus supine position for the prevention of ventilator-associated pneumonia in adults requiring mechanical ventilation.

    Science.gov (United States)

    Wang, Li; Li, Xiao; Yang, Zongxia; Tang, Xueli; Yuan, Qiang; Deng, Lijing; Sun, Xin

    2016-01-08

    Ventilator-associated pneumonia (VAP) is associated with increased mortality, prolonged length of hospital stay and increased healthcare costs in critically ill patients. Guidelines recommend a semi-recumbent position (30º to 45º) for preventing VAP among patients requiring mechanical ventilation. However, due to methodological limitations in existing systematic reviews, uncertainty remains regarding the benefits and harms of the semi-recumbent position for preventing VAP. To assess the effectiveness and safety of semi-recumbent positioning versus supine positioning to prevent ventilator-associated pneumonia (VAP) in adults requiring mechanical ventilation. We searched CENTRAL (2015, Issue 10), which includes the Cochrane Acute Respiratory Infections Group's Specialised Register, MEDLINE (1946 to October 2015), EMBASE (2010 to October 2015), CINAHL (1981 to October 2015) and the Chinese Biomedical Literature Database (CBM) (1978 to October 2015). We included randomised controlled trials (RCTs) comparing semi-recumbent versus supine positioning (0º to 10º), or RCTs comparing alternative degrees of positioning in mechanically ventilated patients. Our outcomes included clinically suspected VAP, microbiologically confirmed VAP, intensive care unit (ICU) mortality, hospital mortality, length of ICU stay, length of hospital stay, duration of ventilation, antibiotic use and any adverse events. Two review authors independently and in duplicate screened titles, abstracts and full texts, assessed risk of bias and extracted data using standardised forms. We calculated the mean difference (MD) and 95% confidence interval (95% CI) for continuous data and the risk ratio (RR) and 95% CI for binary data. We performed meta-analysis using the random-effects model. We used the grading of recommendations, assessment, development and evaluation (GRADE) approach to grade the quality of evidence. We included 10 trials involving 878 participants, among which 28 participants in two

  6. Does the Supine Position Affect the Nasal Profile in Rhinoplasty Patients? A Comparison of Nasal Anthropometric Measurements in Different Body Positions.

    Science.gov (United States)

    Kim, Su Jin; Ryu, In Yong; Kim, Sung Wan; Lee, Kun Hee

    2017-10-16

    Rhinoplasty surgeons are aware that the nasal profile differs according to body position, namely, the erect position in the consultation room vs the supine position on the operating table. It is not clear whether this difference is caused by an optical illusion or skin laxity due to positional change. To evaluate anthropometric measurements of the nose with different body positions and determine whether the supine position affects the nasal profile. In this retrospective study, 103 patients who underwent primary rhinoplasty were enrolled. Preoperatively, all patients underwent lateral cephalography in the erect position, and facial computed tomography (CT), in the supine position. We measured four nasal anthropometric parameters (the nasofrontal, nasolabial, and nasomental angles, and Simon's ratio) on lateral cephalograms and facial CT images, and compared these parameters between the two body positions. The nasofrontal angle was greater on facial CT than on cephalograms (P sex, or body mass index (P > 0.05 each). We found no significant difference (P > 0.05) between the two positions in the nasolabial angle, nasomental angle, or Simon's ratio. The supine position does affect the nasal profile, especially in the radix area. Surgeons need to consider this difference in patients undergoing rhinoplasty. 2. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  7. Effects of supine, prone, and lateral positions on cardiovascular and renal variables in humans

    DEFF Research Database (Denmark)

    Pump, Bettina; Talleruphuus, Ulrik; Christensen, Niels Juel

    2002-01-01

    The hypothesis was tested that changing the direction of the transverse gravitational stress in horizontal humans modulates cardiovascular and renal variables. On different study days, 14 healthy males were placed for 6 h in either the horizontal supine or prone position following 3 h of being...... supine. Eight of the subjects were in addition investigated in the horizontal left lateral position. Compared with supine, the prone position slightly increased free water clearance (349 +/- 38 vs. 447 +/- 39 ml/6 h, P = 0.05) and urine output (1,387 +/- 55 vs. 1,533 +/- 52 ml/6 h, P = 0...

  8. Is the modified Tardieu scale in semi-standing position better associated with knee extension and hamstring activity in terminal swing than the supine Tardieu?

    NARCIS (Netherlands)

    Faber, I.R.; Nienhuis, B.; Rijs, N.P.; Geurts, A.C.H.; Duysens, J.E.J.

    2008-01-01

    The aim of this study was to investigate whether the modified Tardieu scale (MTS) in a semi-standing position, used for the assessment of hamstrings spasticity, was better associated with knee extension and hamstrings activity in terminal swing than the MTS in a supine position in children with

  9. Dynamic loop gain increases upon adopting the supine body position during sleep in patients with obstructive sleep apnoea.

    Science.gov (United States)

    Joosten, Simon A; Landry, Shane A; Sands, Scott A; Terrill, Philip I; Mann, Dwayne; Andara, Christopher; Skuza, Elizabeth; Turton, Anthony; Berger, Philip; Hamilton, Garun S; Edwards, Bradley A

    2017-11-01

    Obstructive sleep apnoea (OSA) is typically worse in the supine versus lateral sleeping position. One potential factor driving this observation is a decrease in lung volume in the supine position which is expected by theory to increase a key OSA pathogenic factor: dynamic ventilatory control instability (i.e. loop gain). We aimed to quantify dynamic loop gain in OSA patients in the lateral and supine positions, and to explore the relationship between change in dynamic loop gain and change in lung volume with position. Data from 20 patients enrolled in previous studies on the effect of body position on OSA pathogenesis were retrospectively analysed. Dynamic loop gain was calculated from routinely collected polysomnographic signals using a previously validated mathematical model. Lung volumes were measured in the awake state with a nitrogen washout technique. Dynamic loop gain was significantly higher in the supine than in the lateral position (0.77 ± 0.15 vs 0.68 ± 0.14, P = 0.012). Supine functional residual capacity (FRC) was significantly lower than lateral FRC (81.0 ± 15.4% vs 87.3 ± 18.4% of the seated FRC, P = 0.021). The reduced FRC we observed on moving to the supine position was predicted by theory to increase loop gain by 10.2 (0.6, 17.1)%, a value similar to the observed increase of 8.4 (-1.5, 31.0)%. Dynamic loop gain increased by a small but statistically significant amount when moving from the lateral to supine position and this may, in part, contribute to the worsening of OSA in the supine sleeping position. © 2017 Asian Pacific Society of Respirology.

  10. SU-E-J-227: Breathing Pattern Consistency and Reproducibility: Comparative Analysis for Supine and Prone Body Positioning

    International Nuclear Information System (INIS)

    Laugeman, E; Weiss, E; Chen, S; Hugo, G; Rosu, M

    2014-01-01

    Purpose: Evaluate and compare the cycle-to-cycle consistency of breathing patterns and their reproducibility over the course of treatment, for supine and prone positioning. Methods: Respiratory traces from 25 patients were recorded for sequential supine/prone 4DCT scans acquired prior to treatment, and during the course of the treatment (weekly or bi-weekly). For each breathing cycle, the average(AVE), end-of-exhale(EoE) and end-of-inhale( EoI) locations were identified using in-house developed software. In addition, the mean values and variations for the above quantities were computed for each breathing trace. F-tests were used to compare the cycle-to-cycle consistency of all pairs of sequential supine and prone scans. Analysis of variances was also performed using population means for AVE, EoE and EoI to quantify differences between the reproducibility of prone and supine respiration traces over the treatment course. Results: Consistency: Cycle-to-cycle variations are less in prone than supine in the pre-treatment and during-treatment scans for AVE, EoE and EoI points, for the majority of patients (differences significant at p<0.05). The few cases where the respiratory pattern had more variability in prone appeared to be random events. Reproducibility: The reproducibility of breathing patterns (supine and prone) improved as treatment progressed, perhaps due to patients becoming more comfortable with the procedure. However, variability in supine position continued to remain significantly larger than in prone (p<0.05), as indicated by the variance analysis of population means for the pretreatment and subsequent during-treatment scans. Conclusions: Prone positioning stabilizes breathing patterns in most subjects investigated in this study. Importantly, a parallel analysis of the same group of patients revealed a tendency towards increasing motion amplitude of tumor targets in prone position regardless of their size or location; thus, the choice for body positioning

  11. Difference in human cardiovascular response between upright and supine recovery from upright cycle exercise.

    Science.gov (United States)

    Takahashi, T; Okada, A; Saitoh, T; Hayano, J; Miyamoto, Y

    2000-02-01

    Cardiovascular responses were examined in seven healthy male subjects during 10 min of recovery in the upright or supine position following 5 min of upright cycle exercise at 80% peak oxygen uptake. An initial rapid decrease in heart rate (fc) during the early phase of recovery followed by much slower decrease was observed for both the upright and supine positions. The average fc at the 10th min of recovery was significantly lower (P position than in the upright position, while they were both significantly greater than the corresponding pre-exercise levels (each P positions was reduced with a decrease in mean R-R interval, the relationship being expressed by a regression line--mean R-R interval = 0.006 x HF amplitude + 0.570 (r = 0.905, n = 28, P positions is partly attributable to a retardation in the restoration of the activity of the cardiac parasympathetic nervous system. Post-exercise upright stroke volume (SV, by impedance cardiography) decreased gradually to just below the pre-exercise level, whereas post-exercise supine SV increased markedly to a level similar to that at rest before exercise. The resultant cardiac output (Qc) and the total peripheral vascular resistance (TPR) in the upright and supine positions returned gradually to their respective pre-exercise levels in the corresponding positions. At the 10th min of recovery, both average SV and Qc were significantly greater (each P position, while average TPR was significantly lower (P position. In contrast, immediately after exercise, mean blood pressure dropped markedly in both the supine and upright positions, and their levels at the 10th min of recovery were similar. Therefore we concluded that arterial blood pressure is maintained relatively constant through various compensatory mechanisms associated with fc, SV, Qc, and TPR during rest and recovery in different body positions.

  12. Supine exercise during lower body negative pressure effectively simulates upright exercise in normal gravity

    Science.gov (United States)

    Murthy, G.; Watenpaugh, D. E.; Ballard, R. E.; Hargens, A. R.

    1994-01-01

    Exercise within a lower body negative pressure (LBNP) chamber in supine posture was compared with similar exercise against Earth's gravity (without LBNP) in upright posture in nine healthy male volunteers. We measured footward force with a force plate, pressure in soleus and tibialis anterior muscles of the leg with transducer-tipped catheters, calf volume by strain gauge plethysmography, heart rate, and systolic and diastolic blood pressures during two conditions: 1) exercise in supine posture within an LBNP chamber during 100-mmHg LBNP (exercise-LBNP) and 2) exercise in upright posture against Earth's gravity without LBNP (exercise-1 G). Subjects exercised their ankle joints (dorsi- and plantarflexions) for 5 min during exercise-LBNP and for 5 min during exercise-1 G. Mean footward force produced during exercise-LBNP (743 +/- 37 N) was similar to that produced during exercise-1 G (701 +/- 24 N). Peak contraction pressure in the antigravity soleus muscle during exercise-LBNP (115 +/- 10 mmHg) was also similar to that during exercise-1 G (103 +/- 13 mmHg). Calf volume increased significantly by 3.3 +/- 0.5% during exercise-LBNP compared with baseline values. Calf volume did not increase significantly during exercise-1 G. Heart rate was significantly higher during exercise-LBNP (99 +/- 5 beats/min) than during exercise-1 G (81 +/- 3 beats/min). These results indicate that exercise in supine posture within an LBNP chamber can produce similar musculoskeletal stress in the legs and greater systemic cardiovascular stress than exercise in the upright posture against Earth's gravity.

  13. CT simulation technique for craniospinal irradiation in supine position

    International Nuclear Information System (INIS)

    Lee, Suk; Kim, Yong Bae; Chu, Sung Sil; Suh, Chang Ok; Kwon, Soo Il

    2002-01-01

    In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetric image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was performed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. CSI in the supine position was successfully performed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The difference between the DRRs and the portal films were less than 3 mm in the vertebral contour. CSI in the supine position is feasible in patients who cannot lie on

  14. CT simulation technique for craniospinal irradiation in supine position

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Suk; Kim, Yong Bae; Chu, Sung Sil; Suh, Chang Ok [Yonsei Cancer Center, College of Medicine, Yonsei University, Seoul (Korea, Republic of); Kwon, Soo Il [Kyonggi University, Seoul (Korea, Republic of)

    2002-06-15

    In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetric image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was performed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. CSI in the supine position was successfully performed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The difference between the DRRs and the portal films were less than 3 mm in the vertebral contour. CSI in the supine position is feasible in patients who cannot

  15. Conventional Supine MRI With a Lumbar Pillow-An Alternative to Weight-bearing MRI for Diagnosing Spinal Stenosis?

    DEFF Research Database (Denmark)

    Hansen, Bjarke Brandt; Hansen, Philip; Grindsted, Jacob

    2017-01-01

    to conventional MRI were included to an additional positional MRI scan (0.25T G-Scan) performed in: (1) conventional supine, (2) standing, (3) supine with a lumbar pillow in the lower back. LSS was evaluated for each position in consensus on a 0 to 3 semi-quantitative grading scale. Independently, L2-S1 lordosis...... included. The lordosis angle increased significantly from supine to standing (3.2° CI: 1.2-5.2) and with the lumbar pillow (12.8° CI: 10.3-15.3). One-way analysis of variance (ANOVA) showed significant differences between positions (P 

  16. Hemodynamic responses to seated and supine lower body negative pressure - Comparison with +Gz acceleration

    Science.gov (United States)

    Polese, Alvese; Sandler, Harold; Montgomery, Leslie D.

    1992-01-01

    The hemodynamic responses to LBNP in seated subjects and in subjects in supine body positions were compared and were correlated with hemodynamic changes which occurred during a simulated (by centrifugation) Shuttle reentry acceleration with a slow onset rate of 0.002 G/s and during gradual onset exposures to +3 Gz and +4 Gz. Results demonstrate that seated LBNP at a level of -40 mm Hg can serve as a static simulator for changes in the heart rate and in mean blood pressure induced by gradual onset acceleration stress occurring during Shuttle reentry. The findings also provide a rationale for using LBNP during weightlessness as a means of imposing G-loading on the circulation prior to reentry.

  17. Body height and arterial pressure in seated and supine young males during +2 G centrifugation

    DEFF Research Database (Denmark)

    Arvedsen, Sine K.; Eiken, Ola; Kölegård, Roger

    2015-01-01

    by the use of a human centrifuge would increase mean arterial pressure (MAP) more in tall than in short males in the seated position. In short (162-171cm, n=8) and tall (194-203cm, n=10) healthy males (18-41yr), brachial arterial pressure, heart rate (HR) and cardiac output were measured during +2G...... centrifugation, while they were seated upright with the legs kept horizontal (+2Gz). In a separate experiment, the same measurements were done with the subjects supine (+2Gx). During +2Gz MAP increased in the short (22±2 mmHg, P 

  18. In-to-out body path loss for wireless radio frequency capsule endoscopy in a human body.

    Science.gov (United States)

    Vermeeren, G; Tanghe, E; Thielens, A; Martens, L; Joseph, W

    2016-08-01

    Physical-layer characterization is important for design of in-to-out body communication for wireless body area networks (WBANs). This paper numerically investigates the path loss of an in-to-out body radio frequency (RF) wireless link between an endoscopy capsule and a receiver outside the body using a 3D electromagnetic solver. A spiral antenna in the endoscopy capsule is tuned to operate in the Medical Implant Communication Service (MICS) band at 402 MHz, accounting for the properties of the human body. The influence of misalignment, rotation of the capsule, and human body model are investigated. Semi-empirical path loss models for various homogeneous tissues and 3D realistic human body models are provided for manufacturers to evaluate the performance of in-to-out-body WBAN systems.

  19. Improving head and body pose estimation through semi-supervised manifold alignment

    KAUST Repository

    Heili, Alexandre

    2014-10-27

    In this paper, we explore the use of a semi-supervised manifold alignment method for domain adaptation in the context of human body and head pose estimation in videos. We build upon an existing state-of-the-art system that leverages on external labelled datasets for the body and head features, and on the unlabelled test data with weak velocity labels to do a coupled estimation of the body and head pose. While this previous approach showed promising results, the learning of the underlying manifold structure of the features in the train and target data and the need to align them were not explored despite the fact that the pose features between two datasets may vary according to the scene, e.g. due to different camera point of view or perspective. In this paper, we propose to use a semi-supervised manifold alignment method to bring the train and target samples closer within the resulting embedded space. To this end, we consider an adaptation set from the target data and rely on (weak) labels, given for example by the velocity direction whenever they are reliable. These labels, along with the training labels are used to bias the manifold distance within each manifold and to establish correspondences for alignment.

  20. Setup accuracy for prone and supine whole breast irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Mulliez, Thomas; Vercauteren, Tom; Greveling, Annick van; Speleers, Bruno; Neve, Wilfried de; Veldeman, Liv [University Hospital Ghent, Department of Radiotherapy, Ghent (Belgium); Gulyban, Akos [University Hospital Ghent, Department of Radiotherapy, Ghent (Belgium); University Hospital Liege, Department of Radiotherapy, Liege (Belgium)

    2016-04-15

    To evaluate cone-beam computed tomography (CBCT) based setup accuracy and margins for prone and supine whole breast irradiation (WBI). Setup accuracy was evaluated on 3559 CBCT scans of 242 patients treated with WBI and uncertainty margins were calculated using the van Herk formula. Uni- and multivariate analysis on individual margins was performed for age, body mass index (BMI) and cup size. The population-based margin in vertical (VE), lateral (LA) and longitudinal (LO) directions was 10.4/9.4/9.4 mm for the 103 supine and 10.5/22.4/13.7 mm for the 139 prone treated patients, being significantly (p < 0.01) different for the LA and LO directions. Multivariate analysis identified a significant (p < 0.05) correlation between BMI and the LO margin in supine position and the VE/LA margin in prone position. In this series, setup accuracy is significantly worse in prone compared to supine position for the LA and LO directions. However, without proper image-guidance, uncertainty margins of about 1 cm are also necessary for supine WBI. For patients with a higher BMI, larger margins are required. (orig.) [German] Ziel der Arbeit war es, die interfraktionelle Repositionierungsgenauigkeit in Bauchlage (BL) versus Rueckenlage (RL) bei Ganzbrustbestrahlung (GBB) mittels Cone-Beam-CT (CBCT) zu bestimmen, um die notwendigen PTV-Sicherheitsabstaende zu definieren. Die Repositionierungsgenauigkeit wurde basierend an 3559 CBCT-Scans von 242 mit GBB behandelten Patienten ausgewertet. Die PTV-Sicherheitsabstaende wurden unter Verwendung der ''van-Herk''-Formel berechnet. Uni- und multivariable Analysen wurden fuer Sicherheitsabstaende in jede Richtung auf Basis von Alter, Body-Mass-Index (BMI) und Koerbchengroesse durchgefuehrt. Die basierend auf den taeglichen CBCT-Verschiebungen berechneten PTV-Sicherheitsabstaende betrugen in anteroposteriorer (AP), lateraler (LT oder links-rechts) und kraniokaudaler (CC) Richtung 10,4/9,4/9,4 mm fuer die RL (103 Patienten) und

  1. Nasal obstruction and sleep-disordered breathing: the effect of supine body position on nasal measurements in snorers.

    Science.gov (United States)

    Virkkula, Paula; Maasilta, Paula; Hytönen, Maija; Salmi, Tapani; Malmberg, Henrik

    2003-06-01

    Nasal obstruction is considered to be a potential etiological factor in sleep-disordered breathing. However, a significant correlation between nasal measurements and obstructive sleep apnea has not been demonstrated so far. The aim of this study was to investigate the relationships between nasal resistance, nasal volumes and selected sleep parameters using nasal measurements performed in both seated and supine positions. We also investigated whether snoring patients in our clinical sample showed increased positional or decongestive nasal mucosal changes. Forty-one snoring men on a waiting list for correction of nasal obstruction underwent polysomnography, anterior rhinomanometry and acoustic rhinometry. Nineteen non-snoring control subjects were also recruited. Nasal measurements were performed in a seated position, after lying down in a supine position and, after decongestion of nasal mucosa, in a seated position again. In the overall patient group, nasal volume at a distance 2-4 cm from the nares in the supine position correlated inversely with apnea-hypopnea index (AHI) (r = -0.32, p patients, total nasal resistance measured in a supine position correlated with AHI (r = 0.50, p position and sleep parameters. Postural or decongestive changes in nasal measurements were not increased in snoring patients compared with control subjects. The relationship found between nasal measurements and sleep parameters suggests that nasal obstruction does augment airway collapse.

  2. Fluid Redistribution and Heart Rate in Humans During Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure

    Science.gov (United States)

    Watenpaugh, D. E.; Breit, G. A.; Ballard, R. E.; Murthy, G.; Hargens, A. R.

    1994-01-01

    Gravity creates blood pressure gradients which redistribute body fluids towards the feet. Positive G(z) centrifugation and lower body negative pressure (LBNP) have been proposed to simulate these and other effects of gravity during long-term existence in microgravity. We hypothesized that the magnitude of upper-to-lower body fluid redistribution would increase according to the following order: short-arm centrifugation (SAC), long-arm centrifugation (LAC), head-up tilt (HUT), and LBNP. To test this hypothesis, we employed strain gauge plethysmography of the neck, thigh and calf during HUT and supine SAC and LAC up to lG(z) at the feet, and during supine LBNP to 100 mm Hg. Supine 100 mm Hg LBNP generates footward force and produces transmural blood pressures in the foot approximately equal to 1 G(z) (90 deg) HUT. Heart rate was measured via cardiotachometry. Control measurements were made while supine. SAC and LAC elicited similar increases in thigh volume at 1 G(z) (2.3 +/- 0.4 and 2.1 +/- 0.1%, respectively; mean +/- se, n greater than or equal to 7). At 100 mm Hg LBNP, thigh volume increased (3.4 +/- 0.3%) significantly more than during l G(z) centrifugation (p less than 0.05). Surprisingly, due to a paradoxical 0.6% reduction of thigh volume between 0.8 and 1.0 G(z) HUT, thigh volume was increased only 0.6 +/- 0.3% at 1 G(z) HUT. The calf demonstrated similar, although less definitive, responses to the various gravitational stimuli. Neck volume tended to decrease less during HUT than during the other stimuli. Heart rate increased similarly during HUT (18 +/- 2 beats/min) and LAC (12 +/- 2 beats/min), and exhibited still greater elevation during LBNP (29 +/- 4 beats/min), yet did not increase during SAC. These results suggest upright posture activates mechanisms that counteract footward fluid redistribution which are not activated during supine applications of simulated gravity. LAC more closely approximated effects of normal gravity (HUT) than LBNP. Therefore

  3. Normovolemia defined according to cardiac stroke volume in healthy supine humans

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Morten; Jørgensen, Christoffer C; Kehlet, Henrik

    2010-01-01

    , mean +/- SD), SV was measured by esophageal Doppler before and after fluid administration to evaluate whether SV increases in healthy, non-fasting, supine subjects. Two hundred millilitres of a synthetic colloid (hydroxyethyl starch, HES 130/0.4) was provided and repeated if a >or=10% increment in SV...

  4. CHARACTERISTICS OF MAXIMUM PERFORMANCE OF PEDALING EXERCISE IN RECUMBENT AND SUPINE POSITIONS

    Directory of Open Access Journals (Sweden)

    Morimasa Kato

    2011-09-01

    Full Text Available To determine the characteristics of maximum pedaling performance in the recumbent and supine positions, maximum isokinetic leg muscle strength was measured in eight healthy male subjects during pedaling at three velocities (300°/s, 480°/s, and 660°/s, and maximum incremental tests were performed for each position. The maximum isokinetic muscle strength in the recumbent position was 210.0 ± 29.2 Nm at 300°/s, 158.4 ± 19.8 Nm at 480°/s, and 110.6 ± 13.2 at 660°/s. In contrast, the muscle strength in the supine position was 229.3 ± 36.7 Nm at 300°/s, 180. 7 ± 20.3 Nm at 480°/s, and 129.6 ± 14.0 Nm at 660°/s. Thus, the maximum isokinetic muscle strength showed significantly higher values in the supine position than in the recumbent position at all angular velocities. The knee and hip joint angles were measured at peak torque using a goniometer; the knee joint angle was not significantly different between both positions, whereas the hip joint angle was greater in the supine position than in the recumbent position (Supine position: 137.3 ± 9. 33 degree at 300°/s, 140.0 ± 11.13 degrees at 480°/s, and 141.0 ± 9.61 degrees at 660°/s. Recumbent position: 99.5 ± 12.21 degrees at 300°/s, 101.6 ± 12.29 degrees at 480°/s, and 105.8 ± 14.28 degrees at 660°/s. Peak oxygen uptake was higher in the recumbent position (50.3 ± 4.43 ml·kg-1·min-1 than in the supine position (48.7 ± 5.10 ml·kg-1·min-1. At maximum exertion, the heart rate and whole-body rate of perceived exertion (RPE were unaffected by position, but leg muscle RPE was higher in the supine position (19.5 ± 0.53 than in the recumbent position (18.8 ± 0.71. These results suggest that the supine position is more suitable for muscle strength exertion than the recumbent position, and this may be due to different hip joint angles between the positions. On the contrary, the endurance capacity was higher in the recumbent position than in the supine position. Since leg muscle

  5. Stress distribution in a semi-infinite body symmetrically loaded over a circular area

    Science.gov (United States)

    Mcginness, H.

    1980-01-01

    Algorithms are developed for computing stresses in a semi-infinite body when loaded by a uniform pressure acting over a circular area. The algorithm allows easy determination of any stress component in a semi-infinite body having a known Poisson's ratio. Example curves are plotted for Portland cement grout and metal representative values.

  6. Modified supine versus prone percutaneous nephrolithotomy: Surgical outcomes from a tertiary teaching hospital

    Directory of Open Access Journals (Sweden)

    Madeleine Nina Jones

    2016-07-01

    Full Text Available Purpose: The traditional prone positioning of percutaneous nephrolithotomy (PCNL is associated with various anesthetic and logistic difficulties. We aimed to compare the surgical outcomes of PCNLs performed using our modified supine position with those performed in the standard prone position. Materials and Methods: A prospective group of 236 renal units (224 patients undergoing PCNL were included in this 2 site study: 160 were performed in the modified supine position were compared with 76 undergoing PCNL in the prone position. The outcomes of radiation dose, radiation time, stone free rate, body mass index (BMI, stone size, operative time, length of stay (LOS, in hospital and complications were compared. Chi-square and t-tests were used. Results: There were no significant differences in mean radiation time, radiation dose or stone size between the modified supine and prone groups. The supine group had a higher mean BMI (31 kg/m2 vs. 28 kg/m2 , p=0.03, shorter mean surgical time (93 minutes vs. 123 minutes, p<0.001, shorter mean LOS (2 days vs. 3 days, p=0.005 and higher stone free rate (70% vs. 50%, p=0.005. There were no differences in septic or bleeding complications but the prone group had a higher rate of overall complications. Conclusions: Modified supine PCNL has significantly lower operative time, shorter LOS and higher stone-free rate compared with prone in our series, while remaining a safe procedure.

  7. Analysis of the effects of non-supine sleeping positions on the stress, strain, deformation and intraocular pressure of the human eye

    Science.gov (United States)

    Volpe, Peter A.

    This thesis presents analytical models, finite element models and experimental data to investigate the response of the human eye to loads that can be experienced when in a non-supine sleeping position. The hypothesis being investigated is that non-supine sleeping positions can lead to stress, strain and deformation of the eye as well as changes in intraocular pressure (IOP) that may exacerbate vision loss in individuals who have glaucoma. To investigate the quasi-static changes in stress and internal pressure, a Fluid-Structure Interaction simulation was performed on an axisymmetrical model of an eye. Common Aerospace Engineering methods for analyzing pressure vessels and hyperelastic structural walls are applied to developing a suitable model. The quasi-static pressure increase was used in an iterative code to analyze changes in IOP over time.

  8. Reliability of isometric subtalar pronator and supinator strength testing.

    Science.gov (United States)

    Hagen, Marco; Lahner, Matthias; Winhuysen, Martin; Maiwald, Christian

    2015-01-01

    Due to the specific anatomy of the subtalar joint with its oblique axis, isometric pronator and supinator strength is not well documented. The purpose of this study was to determine intra- and between-session reliability of pronator and supinator strength and lower leg muscle activity measurements during maximum voluntary isometric contractions (MVIC). Pronator and supinator peak torques (PT), with and without supplementary visual muscle strength biofeedback (FB), and muscular activities of peroneus longus (PL) and tibialis anterior (TA) were assessed twice 3 days apart by the same examiner in 21 healthy young male adults (mean age: 27.6 years; SD = 3.9). Limits of agreement (LoA) and minimum detectable change (MDC) were evaluated. By applying FB, reliability of both pronator and supinator PT was improved: LoA were reduced from 32% to 26% and from 20% to 18% and MDC from 20% to 15% and from 16% to 12% in supinator and pronator PT, respectively. Learning effects in pronator and supinator PT (p isometric subtalar pronator and supinator strength testing is reliable in healthy subjects. LoA of 18% and 26% have to be exceeded for pronator and supinator PT, respectively, to detect relevant effects in repeated measures.

  9. Isometric elbow extensors strength in supine- and prone-lying positions.

    Science.gov (United States)

    Abdelzaher, Ibrahim E; Ababneh, Anas F; Alzyoud, Jehad M

    2013-01-01

    The purpose of this study was to compare isometric strength of elbow extensors measured in supine- and prone-lying positions at elbow flexion angles of 45 and 90 degrees. Twenty-two male subjects under single-blind procedures participated in the study. Each subject participated in both supine-lying and prone-lying measuring protocols. Calibrated cable tensiometer was used to measure isometric strength of the right elbow extensors and a biofeedback electromyography was used to assure no substitution movements from shoulder girdle muscles. The mean values of isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees were 11.1  ±  4.2 kg and 13.1  ±  4.6 kg, while those measured from prone-lying position were 9.9  ±  3.6 kg and 12  ±  4.2 kg, respectively. There is statistical significant difference between the isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees compared to that measured from prone-lying position (p  isometric strength of elbow extensors since supine-lying starting position is better than prone-lying starting position.

  10. How well tolerated is supine percutaneous nephrolithotomy?

    NARCIS (Netherlands)

    Baard, Joyce; Kamphuis, Guido M.; Westendarp, Matias; de La Rosette, Jean J. M. C. H.

    2014-01-01

    Supine percutaneous nephrolithotomy (PCNL) has been described in 1988 and several modifications followed since. Despite claimed benefits, supine PCNL is still neglected by the majority of urologists. Lack of experience and the fear of complications are possible explanations for the resistance to

  11. Goal-directed fluid therapy: stroke volume optimisation and cardiac dimensions in supine healthy humans

    DEFF Research Database (Denmark)

    Jans, O.; Tollund, C.; Bundgaard-Nielsen, M.

    2008-01-01

    BACKGROUND: Based on maximisation of cardiac stroke volume (SV), peri-operative individualised goal-directed fluid therapy improves patient outcome. It remains, however, unknown how fluid therapy by this strategy relates to filling of the heart during supine rest as reference for the anaesthetised...... by thoracic electrical admittance, central venous oxygenation and pressure, and arterial plasma atrial natriuretic peptide. Also, muscle and brain oxygenation were assessed by near infrared spectroscopy (n=7). RESULTS: The HUT reduced the mentioned indices of CBV, the end-diastolic dimensions of the heart...... therapy is that when a maximal SV is established for patients, cardiac pre-load is comparable to that of supine healthy subjects Udgivelsesdato: 2008/4...

  12. Slice-based supine-to-standing posture deformation for chinese anatomical models and the dosimetric results with wide band frequency electromagnetic field exposure: Simulation

    International Nuclear Information System (INIS)

    Wu, T.; Tan, L.; Shao, Q.; Li, Y.; Yang, L.; Zhao, C.; Xie, Y.; Zhang, S.

    2013-01-01

    Standing Chinese adult anatomical models are obtained from supine-postured cadaver slices. This paper presents the dosimetric differences between the supine and the standing postures over wide band frequencies and various incident configurations. Both the body level and the tissue/organ level differences are reported for plane wave and the 3T magnetic resonance imaging radiofrequency electromagnetic field exposure. The influence of posture on the whole body specific absorption rate and tissue specified specific absorption rate values is discussed. . (authors)

  13. Cardiovascular regulation during body unweighting by lower body positive pressure.

    Science.gov (United States)

    Evans, Joyce M; Mohney, Lindsay; Wang, Siqi; Moore, Rachel K; Elayi, Samy-Claude; Stenger, Michael B; Moore, Fritz B; Knapp, Charles F

    2013-11-01

    We hypothesized that human cardiovascular responses to standing in reduced gravity environments, as on the Moon or Mars, could be modeled using a lower body positive pressure (LBPP) chamber. Heart rate, blood pressure, body segment fluid shifts, ECG, indexes of sympathetic, parasympathetic balance, and baroreflex control of the heart and periphery plus echocardiographic measures of cardiac function were recorded from seven men and seven women supine and standing at 100% (Earth), 40% (-Mars), and 20% (-Moon) bodyweights (BW). The fluid shifted from the chest was greater when standing at 100% BW than at 20% and 40% BW, while fluid pooled in the abdomen was similar at all BWs. Compared to moving from supine to standing at 100% BW, moving to 20% and 40% BW resulted in smaller decreases in stroke volume and pulse pressure, smaller increases in heart rate and smaller decreases in parasympathetic control of heart rate, baroreflex slope, numbers of blood pressure ramps, and much reduced indexes of sympathetic drive to the heart and periphery. However, peripheral vascular resistance, systolic pressure, and baroreflex effectiveness were elevated during 20% and 40% BW, compared to supine and standing at 100% BW. Standing at reduced bodyweight suppressed indexes of sympathetic control of heart rate and peripheral vasomotion. Regulatory responses indicated a combination of arterial and cardiopulmonary baroreflex control: mean heart rate, vasomotion, and baroreflex sensitivity appeared to be more under cardiopulmonary control while baroreflex effectiveness appeared to be driven more by the arterial baroreflex.

  14. Supinator Extender (SUE): a pneumatically actuated robot for forearm/wrist rehabilitation after stroke.

    Science.gov (United States)

    Allington, James; Spencer, Steven J; Klein, Julius; Buell, Meghan; Reinkensmeyer, David J; Bobrow, James

    2011-01-01

    The robot described in this paper, SUE (Supinator Extender), adds forearm/wrist rehabilitation functionality to the UCI BONES exoskeleton robot and to the ArmeoSpring rehabilitation device. SUE is a 2-DOF serial chain that can measure and assist forearm supination-pronation and wrist flexion-extension. The large power to weight ratio of pneumatic actuators allows SUE to achieve the forces needed for rehabilitation therapy while remaining lightweight enough to be carried by BONES and ArmeoSpring. Each degree of freedom has a range of 90 degrees, and a nominal torque of 2 ft-lbs. The cylinders are mounted away from the patient's body on the lateral aspect of the arm. This is to prevent the danger of a collision and maximize the workspace of the arm robot. The rotation axis used for supination-pronation is a small bearing just below the subject's wrist. The flexion-extension motion is actuated by a cantilevered pneumatic cylinder, which allows the palm of the hand to remain open. Data are presented that demonstrate the ability of SUE to measure and cancel forearm/wrist passive tone, thereby extending the active range of motion for people with stroke.

  15. Pronation-Supination Motion Is Altered in a Rat Model of Post-Traumatic Elbow Contracture.

    Science.gov (United States)

    Dunham, Chelsey L; Castile, Ryan M; Chamberlain, Aaron M; Galatz, Leesa M; Lake, Spencer P

    2017-07-01

    The elbow joint is highly susceptible to joint contracture, and treating elbow contracture is a challenging clinical problem. Previously, we established an animal model to study elbow contracture that exhibited features similar to the human condition including persistent decreased range of motion (ROM) in flexion-extension and increased capsule thickness/adhesions. The objective of this study was to mechanically quantify pronation-supination in different injury models to determine if significant differences compared to control or contralateral persist long-term in our animal elbow contracture model. After surgically inducing soft tissue damage in the elbow, Injury I (anterior capsulotomy) and Injury II (anterior capsulotomy with lateral collateral ligament transection), limbs were immobilized for 6 weeks (immobilization (IM)). Animals were evaluated after the IM period or following an additional 6 weeks of free mobilization (FM). Total ROM for pronation-supination was significantly decreased compared to the uninjured contralateral limb for both IM and FM, although not different from control limbs. Specifically, for both IM and FM, total ROM for Injury I and Injury II was significantly decreased by ∼20% compared to contralateral. Correlations of measurements from flexion-extension and pronation-supination divulged that FM did not affect these motions in the same way, demonstrating that joint motions need to be studied/treated separately. Overall, injured limbs exhibited persistent motion loss in pronation-supination when comparing side-to-side differences, similar to human post-traumatic joint contracture. Future work will use this animal model to study how elbow periarticular soft tissues contribute to contracture.

  16. The 2-Year Cosmetic Outcome of a Randomized Trial Comparing Prone and Supine Whole-Breast Irradiation in Large-Breasted Women

    Energy Technology Data Exchange (ETDEWEB)

    Veldeman, Liv, E-mail: liv.veldeman@uzgent.be [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); Department of Radiotherapy and Experimental Cancer Research, Ghent University, Ghent (Belgium); Schiettecatte, Kimberly; De Sutter, Charlotte; Monten, Christel; Greveling, Annick van [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); Berkovic, Patrick [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); Department of Radiation Oncology, Centre Hospitalier Universitaire de Liège, Liège (Belgium); Mulliez, Thomas [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); De Neve, Wilfried [Department of Radiation Oncology, University Hospital Ghent, Ghent (Belgium); Department of Radiotherapy and Experimental Cancer Research, Ghent University, Ghent (Belgium)

    2016-07-15

    Purpose: To report the 2-year cosmetic outcome of a randomized trial comparing prone and supine whole-breast irradiation in large-breasted patients. Methods and Materials: One hundred patients with a (European) cup size ≥C were included. Before and 2 years after radiation therapy, clinical endpoints were scored and digital photographs were taken with the arms alongside the body and with the arms elevated 180°. Three observers rated the photographs using the 4-point Harvard cosmesis scale. Cosmesis was also evaluated with the commercially available Breast Cancer Conservation Treatment.cosmetic results (BCCT.core) software. Results: Two-year follow-up data and photographs were available for 94 patients (47 supine treated and 47 prone treated). Patient and treatment characteristics were not significantly different between the 2 cohorts. A worsening of color change occurred more frequently in the supine than in the prone cohort (19/46 vs 10/46 patients, respectively, P=.04). Five patients in the prone group (11%) and 12 patients in the supine group (26%) presented with a worse scoring of edema at 2-year follow-up (P=.06). For retraction and fibrosis, no significant differences were found between the 2 cohorts, although scores were generally worse in the supine cohort. The cosmetic scoring by 3 observers did not reveal differences between the prone and supine groups. On the photographs with the hands up, 7 patients in the supine group versus none in the prone group had a worsening of cosmesis of 2 categories using the (BCCT.org) software (P=.02). Conclusion: With a limited follow-up of 2 years, better cosmetic outcome was observed in prone-treated than in supine-treated patients.

  17. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R(2) = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway...

  18. Supine vs decubitus lateral patient positioning in vertebral fracture assessment.

    Science.gov (United States)

    Paggiosi, Margaret Anne; Finigan, Judith; Peel, Nicola; Eastell, Richard; Ferrar, Lynne

    2012-01-01

    In vertebral fracture assessment (VFA), lateral scans are obtained with the patient positioned supine (C-arm densitometers) or lateral decubitus (fixed-arm densitometers). We aimed to determine the impact of positioning on image quality and fracture definition. We performed supine and decubitus lateral VFA in 50 postmenopausal women and used the algorithm-based qualitative method to identify vertebral fractures. We compared the 2 techniques for the identification of fractures (kappa analysis) and compared the numbers of unreadable vertebrae (indiscernible endplates) and vertebrae that were projected obliquely (Wilcoxon matched-pairs signed-rank test). The kappa score for agreement between the VFA techniques (to identify women with vertebral fractures) was 0.84 (95% confidence interval [CI]: 0.68-0.99), and for agreement with fracture assessments made from radiographs, kappa was 0.76 (95% CI: 0.57-0.94) for both supine and decubitus lateral VFA. There were more unreadable vertebrae with supine lateral (48 vertebrae in supine lateral compared with 14 in decubitus lateral; p=0.001), but oblique projection was less common (93 vertebrae compared with 145 in decubitus lateral; p=0.002). We conclude that there were significantly different projection effects with supine and decubitus lateral VFA, but these differences did not influence the identification of vertebral fractures in our study sample. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of supine and sitting cardiac blood pool scans with sup(99m)Tc-HSA

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Kuwajima, Akira; Hisada, Kinichi

    1977-01-01

    In the differential diagnosis of enlarged cardiac silhouette on plain chest x-ray film, cardiac blood pool scan was usually performed at first. However, small amount of pericardial effusion was difficult to detect on cardiac blood pool scan and differentiation of pericardial effusion from myocardial thickening was sometimes difficult. We evaluated cardiac blood pool scan with sup(99m)Tc-HSA(human serum albumin) and gamma camera imaged on both supine and sitting position, and evaluated diagnostic efficiency of criteria for pericardial effusion of these scans. Fifty-seven patients suspected of having pericardial effusion were included in the study. Sixteen of these patients had pericardial effusion and 2 of these 16 patients had free pleural effusion. Three patients had pleural effusion alone and excluded from the study. Of the five criteria for pericardial effusion, separation between heart and right lung activities was most frequent in both effusion (true positive, TP=100% on both supine and sitting) and no effusion (false positive, FP=18.4% on supine and 23.7% on sitting) groups. However, increased heart and right lung separation on sitting position was rather frequent in effusion group, and this finding was also thought to be typical for effusion but not for myocardial thickening. Decreased cardiohepatic separation on sitting position was frequent in no effusion group, and FP rate was decreased from 18.4% (supine) to 10.5% (sitting). Two patients with both pericardial effusion and free pleural effusion were easily diagnosed on sitting cardiac blood pool scan. With ROC(receiver operating characteristic) curve, three criteria should be agreed on either supine or sitting scan for diagnosis of pericardial effusion, and six criteria should be agreed when both supine and sitting scans were employed for diagnosis of pericardial effusion. (auth.)

  20. The diagnostic value of supine blood pressure in hypertension.

    Science.gov (United States)

    Krzesiński, Paweł; Stańczyk, Adam; Gielerak, Grzegorz; Piotrowicz, Katarzyna; Banak, Małgorzata; Wójcik, Agnieszka

    2016-04-01

    Correct blood pressure (BP) measurement is crucial in the diagnosis of arterial hypertension (AH), and controversy exists whether supine BP should be treated as equal to sitting BP. The aim of this study was to evaluate the relation of supine BP to sitting BP and ambulatory BP with regard to identification of diagnostic cut-offs for hypertension. This study included 280 patients with AH (mean age: 44.3 ±10.6 years). The following measurements of BP were performed and analyzed: 1) sitting office blood pressure measurement (OSBP and ODBP); 2) supine BP (supSBP and supDBP), measured automatically (5 times with a 2-minute interval) during evaluation by the Niccomo device (Medis, Germany); 3) 24-hour ambulatory blood pressure (ABP) monitoring. The mean supSBP and supDBP were found to be lower than OSBP and ODBP (130.9 ±14.2 vs. 136.6 ±15.5 mm Hg and 84.8 ±9.4 vs. 87.8 ±10.2 mm Hg, respectively; p AUC: 0.820 vs. 0.550; sensitivity 80.7% vs. 57.4%; specificity 83.2% vs. 52.7%; p blood pressure during a 10-minute supine rest was lower than in the sitting position. The supine blood pressure ≥ 130/80 mm Hg was found to be a specific and sensitive threshold for hypertension.

  1. Body position and late postoperative nocturnal hypoxaemia

    DEFF Research Database (Denmark)

    Rosenberg-Adamsen, S; Stausholm, K; Edvardsen, L

    1997-01-01

    Thirteen patients were monitored for nocturnal body position (supine vs. side) and arterial oxygen saturation pre-operatively and on the second postoperative night after major abdominal surgery. The number of positional changes were significantly decreased after operation (p ... position than on the side (p movements....... towards more time spent in the supine position (p = 0.1). Individual mean arterial oxygen saturation decreased postoperatively (p positions (p = 0.9). Pre-operatively, episodic desaturations were significantly more frequent in the supine...

  2. Peripheral Microvascular Responses to Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure Stresses in Humans

    Science.gov (United States)

    Breit, G. A.; Watenpaugh, D. E.; Buckley, T. M.; Ballard, R. E.; Murthy, G.; Hargens, A. R.

    1994-01-01

    The response of the cutaneous microcirculation to orthostatic stress varies along the length of the body due to the interaction of central controls with regional responses to local blood pressure. We hypothesize that artificial orthostatic stresses such as Gz centrifugation and LBNP differ from whole-body tilting in terms of the distribution of microvascular blood flow. Cutaneous microvascular flows were measured by laser Doppler flowmetry at the neck, thigh, and leg of 15 normal subjects. Volunteers underwent stepwise head-up tilt (HUT) and short- and long-arm centrifugation protocols from supine control (0 Gz) to 0.2, 0.4, 0.6, 0.8, 1.0, 0.8, 0.6, 0.4, 0.2, and 0 Gz at the feet, for 30-s periods with 10-s transitions between levels. The same subjects underwent a corresponding supine LBNP protocol, up to 100 mmHg (in 20 mmHg increments) and back to zero pressure, which produced transmural pressure across blood vessels in the foot approximately equal to the HUT protocol. In general, application of all orthostatic stresses produced significant flow reductions in the lower body (p less than 0.05) and inconsistent changes in the neck. At low levels of each stress (0.4 Gz, 40 mmHg), LBNP generated the greatest relative reduction in flow in the lower body (-66.9+/-5.7%, thigh; -60.6 +/-5.7%, leg, mean +/- SE). HUT caused a less severe flow reduction than LBNP at the thigh and leg (-39.9 +/- 8.1% and -55.9+/-4.8%), while the effects induced by both forms of centrifugation were the least profound. Higher levels of each stress generally resulted in similar responses. These responses exhibit a consistent relationship to hypothesized changes in local microvascular transmural pressure, suggesting that myogenic and veno-arteriolar reflexes play a significant role in determining microvascular perfusion during orthostatic stress.

  3. Comparison of supine and prone positions for percutaneous nephrolithotomy in treatment of staghorn stones.

    Science.gov (United States)

    Gökce, Mehmet İlker; Ibiş, Arif; Sancı, Adem; Akıncı, Aykut; Bağcı, Uygar; Ağaoğlu, Eylül Asya; Süer, Evren; Gülpınar, Ömer

    2017-12-01

    Percutaneous nephrolithotomy (PNL) is the primary treatment modality for management of staghorn stones. PNL in supine position has important advantages over prone positon. However, studies comparing prone and supine positions for PNL in staghorn stone patients have conflicting results, and the aim of the current study was to compare prone and supine positions for PNL in staghorn stone cases. Data of patients underwent PNL for staghorn stones in supine or prone position by a single urologist were collected prospectively. The supine and prone position groups were compared for stone free rate (SFR) and complication rates. All patients were evaluated with NCCT for evaluation of SFR. Chi-square test was used to compare categorical variables and Student t test was applied for continuous variables of the treatment groups. The groups were similar for demographic and stone-related characteristics. Multi-caliceal and intercostal access was more common in prone position. Operation duration was significantly shorter and hemoglobin drop was significantly less in supine group. SFR was 64.1 and 60.4% in the supine and prone groups, respectively (p = 0.72). Complication rates were similar in the two groups but Clavien III complications were observed in two patients in the prone group. PNL in supine position is an effective treatment for management of staghorn stones. The need for multi-caliceal and intercostal puncture is less when combined with retrograde intrarenal surgery. PNL in supine position should be considered as primary treatment option in staghorn stone cases.

  4. Comparison of Organ Location, Morphology, and Rib Coverage of a Midsized Male in the Supine and Seated Positions

    Directory of Open Access Journals (Sweden)

    Ashley R. Hayes

    2013-01-01

    Full Text Available The location and morphology of abdominal organs due to postural changes have implications in the prediction of trauma via computational models. The purpose of this study is to use data from a multimodality image set to devise a method for examining changes in organ location, morphology, and rib coverage from the supine to seated postures. Medical images of a male volunteer (78.6±0.77 kg, 175 cm in three modalities (Computed Tomography, Magnetic Resonance Imaging (MRI, and Upright MRI were used. Through image segmentation and registration, an analysis between organs in each posture was conducted. For the organs analyzed (liver, spleen, and kidneys, location was found to vary between postures. Increases in rib coverage from the supine to seated posture were observed for the liver, with a 9.6% increase in a lateral projection and a 4.6% increase in a frontal projection. Rib coverage area was found to increase 11.7% for the spleen. Morphological changes in the organs were also observed. The liver expanded 7.8% cranially and compressed 3.4% and 5.2% in the anterior-posterior and medial-lateral directions, respectively. Similar trends were observed in the spleen and kidneys. These findings indicate that the posture of the subject has implications in computational human body model development.

  5. A Prospective Study of Intrafraction Prostate Motion in the Prone vs. Supine Position

    International Nuclear Information System (INIS)

    Wilder, Richard B.; Chittenden, Lucy; Mesa, Albert V.; Bunyapanasarn, Jane; Agustin, Jeff; Lizarde, Jessica; Ravera, John; Tokita, Kenneth M.

    2010-01-01

    Purpose: To prospectively analyze prostate intrafraction motion in the prone vs. supine position and to assess patient satisfaction with these two positions. Methods and Materials: Fifteen prostate cancer patients underwent implantation of five fiducial gold seeds in their prostate for localization. Patients were treated with high-dose-rate brachytherapy to 2,200 cGy followed by intensity-modulated radiation therapy (IMRT) to 5,040 cGy. Patients underwent computed tomography simulation and IMRT in the prone position. For the first five IMRT treatments, an electronic portal imaging system was used to acquire anteroposterior (AP) and lateral images pretreatment and posttreatment. We then repositioned each patient supine and repeated the process, resulting in 600 images. Results: Mean ± standard deviation intrafraction prostate motion was 2.1 ± 1.2 mm and 1.7 ± 1.4 mm (AP, p = 0.47), 2.2 ± 2.0 mm and 1.6 ± 1.8 mm (superoinferior, p = 0.16), and 1.0 ± 1.2 mm and 0.6 ± 0.9 mm (left-right, p = 0.03) in the prone and supine positions, respectively. Eighty percent of patients stated that they were more comfortable in the supine position (p = 0.02). Conclusions: Prone and supine positions resulted in a similar magnitude of AP and superoinferior intrafraction prostate motion (2 mm). Because there was no significant difference in the magnitude of AP and superoinferior prostate motion prone vs. supine and patients were more comfortable in the supine position, patients now undergo IMRT to the prostate and seminal vesicles at our center in the supine position.

  6. Supinated forearm is correlated with the onset of medial epicondylitis in professional slalom water-skiers.

    Science.gov (United States)

    Rosa, Donato; Di Donato, Sigismondo Luca; Balato, Giovanni; D'Addona, Alessio; Schonauer, Fabrizio

    2016-01-01

    prolonged and laborious activities involving wrists and forearms has been long associated with the onset of epicondylitis. Slalom water-skiing can be included in this category. The purpose of the study is to analyse the correlation between the pronated or supinated position of forearms during water-skiing practice and the presence respectively of lateral and medial epicondylitis. sixty-six pro and semi-pro slalom water-skiers were enrolled in the study. A questionnaire was submitted to each athlete. Diagnosis of lateral or medial epicondylitis was made through anamnesis and clinical exam by an expert orthopaedic surgeon. Chi-squared were performed for categorical variables, and Mann-Whitney U test for continuous ones. from 116 upper limbs examined, we observed 15 (12.9%) cases of lateral epicondylitis, 30 (25.9%) cases of medial epicondylitis, 10 (8.6%) were affected by both lateral and medial epicondylitis. Lateral and medial epicondylitis were associated (95% C.I.=2,489-26,355; P=epicondylitis (95% C.I.=1,529-9,542; P=0.003). slalom water-skiing can be considered a high-risk sport for epicondylitis. In slalom water-skiers there is a correlation between development of lateral and medial epicondylitis in the same upper limb. Supinated position of forearms is strongly associated with the diagnosis of medial epicondylitis.

  7. Thermal impedance at the interface of contacting bodies: 1-D examples solved by semi-derivatives

    Directory of Open Access Journals (Sweden)

    Hristov Jordan

    2012-01-01

    Full Text Available Simple 1-D semi-infinite heat conduction problems enable to demonstrate the potential of the fractional calculus in determination of transient thermal impedances of two bodies with different initial temperatures contacting at the interface ( x = 0 at t = 0 . The approach is purely analytic and uses only semi-derivatives (half-time and semi-integrals in the Riemann-Liouville sense. The example solved clearly reveals that the fractional calculus is more effective in calculation the thermal resistances than the entire domain solutions.

  8. The Effect of Body Posture on Brain Glymphatic Transport.

    Science.gov (United States)

    Lee, Hedok; Xie, Lulu; Yu, Mei; Kang, Hongyi; Feng, Tian; Deane, Rashid; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2015-08-05

    The glymphatic pathway expedites clearance of waste, including soluble amyloid β (Aβ) from the brain. Transport through this pathway is controlled by the brain's arousal level because, during sleep or anesthesia, the brain's interstitial space volume expands (compared with wakefulness), resulting in faster waste removal. Humans, as well as animals, exhibit different body postures during sleep, which may also affect waste removal. Therefore, not only the level of consciousness, but also body posture, might affect CSF-interstitial fluid (ISF) exchange efficiency. We used dynamic-contrast-enhanced MRI and kinetic modeling to quantify CSF-ISF exchange rates in anesthetized rodents' brains in supine, prone, or lateral positions. To validate the MRI data and to assess specifically the influence of body posture on clearance of Aβ, we used fluorescence microscopy and radioactive tracers, respectively. The analysis showed that glymphatic transport was most efficient in the lateral position compared with the supine or prone positions. In the prone position, in which the rat's head was in the most upright position (mimicking posture during the awake state), transport was characterized by "retention" of the tracer, slower clearance, and more CSF efflux along larger caliber cervical vessels. The optical imaging and radiotracer studies confirmed that glymphatic transport and Aβ clearance were superior in the lateral and supine positions. We propose that the most popular sleep posture (lateral) has evolved to optimize waste removal during sleep and that posture must be considered in diagnostic imaging procedures developed in the future to assess CSF-ISF transport in humans. The rodent brain removes waste better during sleep or anesthesia compared with the awake state. Animals exhibit different body posture during the awake and sleep states, which might affect the brain's waste removal efficiency. We investigated the influence of body posture on brainwide transport of inert

  9. Comparison of supine and prone craniospinal irradiation in children with medulloblastoma.

    Science.gov (United States)

    Verma, Jonathan; Mazloom, Ali; Teh, Bin S; South, Michael; Butler, E Brian; Paulino, Arnold C

    2015-01-01

    To compare port film rejection and treatment outcome according to craniospinal irradiation (CSI) position for medulloblastoma. We retrospectively searched for patients ≤19 years treated with CSI for medulloblastoma at 1 department. We collected the following data: age; sex; risk group; need for general anesthesia; radiation therapy (RT) dose and fractionation; and the acceptance or rejection of weekly port films during treatment. We also collected data on outcomes, including neuraxis recurrence and possible complications such as myelitis. Of 46 children identified, 23 were treated prone (median age, 8.1 years) and 23 supine (median age, 7.2 years). High-risk disease was seen in 26% of prone and 35% of supine patients (P = .25). There was no difference in use of general anesthesia between those treated prone versus supine (57% vs 61%). The rejection rate of cranial port films in the prone position was 35%, which was significantly higher than the rate of 8% in patients treated supine (P < .0001). The 5-year progression-free (P = .37) and overall survival (P = .18) rates were 62% and 67% for prone and 76% and 84% for supine patients. There were no isolated junctional failures or radiation myelitis in either CSI position. The supine position for CSI was found to have similar survival outcomes compared with the prone position. A higher proportion of rejected cranial port films was seen in children treated in the prone position. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  10. Sonographic appearance of a partial rupture of the supinator muscle.

    Science.gov (United States)

    Chen, Chih-Chun; Chiou, Hong-Jen; Kao, Chung-Lan; Chan, Rai-Chi

    2008-05-01

    We report the case of a 51-year-old woman who experienced pain and swelling in the right forearm after spinning cotton. History taking and physical examinations helped identify a tear of the supinator muscle, which was confirmed via sonographic examination. To our knowledge, this article is the first report of a supinator muscle tear diagnosed with sonography. (c) 2008 Wiley Periodicals, Inc. J Clin Ultrasound, 2008.

  11. A Simple Technique of Supine Craniospinal Irradiation

    International Nuclear Information System (INIS)

    Munshi, Anusheel; Jalali, Rakesh

    2008-01-01

    We describe a simple procedure of craniospinal irradiation in supine position. The procedure was carried out with a 100-cm isocenter linear accelerator and compatible simulator. Treatment was with a 1 or 2 posteroanterior (PA)-directed spinal fields abutting lateral-directed cranial fields. Abutment of the fields was established by placement of markers on the neck of the patient, which provided a measure of the divergence of the spinal field. The precision and reproducibility of this technique, including the placement of junctions, appeared to be as good as for treatment in the prone position. The same could be verified with port films. We conclude that this new technique of supine craniospinal treatment is a simple and convenient alternative to traditional treatment in the prone position

  12. Human body communication performance simulations

    OpenAIRE

    Mufti, H. (Haseeb)

    2016-01-01

    Abstract Human Body Communication (HBC) is a novel communication method between devices which use human body as a transmission medium. This idea is mostly based on the concept of wireless biomedical monitoring system. The on-body sensor nodes can monitor vital signs of a human body and use the body as a transmission medium. This technology is convenient for long durations of clinical monitoring with the option of more mobil...

  13. SU-E-T-307: Dosimetric Comparison of Prone Versus Supine Positioning for Adjuvant Breast Radiation Therapy

    International Nuclear Information System (INIS)

    Pope, C; O’Connor, B; Hayes, L; Rella, J; Ruiz, B; Yang, J

    2015-01-01

    Purpose: The prone treatment position has been used to reduce ipsilateral lung and heart dose in left breast radiation. We conducted a retrospective study to evaluate the difference in the dosimetry between prone and supine treatment positions. Methods: Eight left breast cancer patients were simulated in both the supine and prone positions as a pretreatment evaluation for the optimal treatment position. Treatment plans were created for all patients in both the supine and prone positions using a field in field three dimensional planning technique. Prescribed dose was 45 Gy delivered by two tangential photon fields. Irradiated volume (IV) was evaluated by V50, V100, and dose to lung and heart by V5, V10, V20, and the mean dose were evaluated. Results: All dosimetry metrics for both the supine and prone plans met our internal normal structure guidelines which are based on Quantec data. The average IVs (50% and 100%) were 2223cc and 1361cc prone, 2315cc and 1315cc supine. The average ipsilateral lung Mean dose (0.83Gy prone vs 5.8Gy supine), V5 (1.6% prone vs 20.9% supine), V10 (0.78% prone vs 15% supine) and V20 (0.36% prone vs 11% supine) were significantly lower in prone position. Heart Mean dose (1.4Gy prone vs 2.9Gy supine), V10 (1.4% prone vs 5.0% supine) and V20 (0.4% prone vs 3.5% supine) were found improved for all patients except one where the mean dose was the same and all other values were improved. Conclusion: The prone position offer preferable dosimetry for all patients planned in our study. These patients were chosen based on the physician’s belief that they would benefit from prone treatment either because they had large pendulous breasts or due to the amount of heart seen in the field on CT simulation

  14. Physics of the Human Body

    CERN Document Server

    Herman, Irving P

    2007-01-01

    Physics of the Human Body comprehensively addresses the physical and engineering aspects of human physiology by using and building on first-year college physics and mathematics. Topics include the mechanics of the static body and the body in motion, the materials properties of the body, muscles in the body, the energetics of body metabolism, fluid flow in the cardiovascular and respiratory systems, the acoustics of sound waves in speaking and hearing, vision and the optics of the eye, the electrical properties of the body, and the basic engineering principles of feedback and control in regulating all aspects of function. The goal of this text is to understand physical issues concerning the human body, in part by developing and then using simple and subsequently more refined models of the macrophysics of the human body. Many chapters include a brief review of the necessary physical principles. There are problems at the end of each chapter; solutions to selected problems are also provided. This text is geared t...

  15. Radar cross section of human cardiopulmonary activity for recumbent subject.

    Science.gov (United States)

    Kiriazi, John E; Boric-Lubecke, Olga; Lubecke, Victor M

    2009-01-01

    The radar cross section (RCS) corresponding to human cardio-respiratory motion is measured for a subject in two different recumbent positions. Lying face-up (supine), the subject showed an RCS of 0.326 m(2). But when lying face-down (prone), the RCS increased to 2.9 m(2). This is the first reported RCS measurement corresponding to human cardio-respiratory motion. The results obtained in this experiment suggest modeling the upper part of the human body as a half-cylinder where the front body corresponds to the cylindrical surface and the back corresponds to the rectangular one.

  16. Slice-based supine to standing postured deformation for chinese anatomical models and the dosimetric results by wide band frequency electromagnetic field exposure: Morphing

    International Nuclear Information System (INIS)

    Wu, T.; Tan, L.; Shao, Q.; Li, Y.; Yang, L.; Zhao, C.; Xie, Y.; Zhang, S.

    2013-01-01

    Digital human models are frequently obtained from supine-postured medical images or cadaver slices, but many applications require standing models. This paper presents the work of reconstructing standing Chinese adult anatomical models from supine postured slices. Apart from the previous studies, the deformation works on 2-D segmented slices. The surface profile of the standing posture is adjusted by population measurement data. A non-uniform texture amplification approach is applied on the 2-D slices to recover the skin contour and to redistribute the internal tissues. Internal organ shift due to postures is taken into account. The feet are modified by matrix rotation. Then, the supine and standing models are utilised for the evaluation of electromagnetic field exposure over wide band frequency and different incident directions. . (authors)

  17. The supinated mediolateral radiograph for detection of humeral head osteochondrosis in the dog

    International Nuclear Information System (INIS)

    Callahan, T.F.; Ackerman, N.

    1985-01-01

    Mediolateral and supinated mediolateral radiographs of the shoulder joint were compared in 19 dogs. Twenty shoulders, representing 15 dogs (5 had bilateral lesions), had osteochondrosis of the humeral head. The flattened humeral head and subchondral defect were detectable in both views in all affected shoulders. The lesions were slightly more easily detected in the supinated view. The supinated view more consistently demonstrated the presence of a calcified cartilage flap and therefore, could be useful in determining a course of therapy. In four dogs (8 shoulders) without osteochondrosis and six normal shoulders from affected dogs, there were no instances in which a shoulder appeared normal on one view, but demonstrated a lesion on the other. The supinated view should be obtained in addition to the mediolateral view in dogs with osteochondrosis of the humeral head

  18. Vision in semi-aquatic snakes: Intraocular morphology, accommodation, and eye: Body allometry

    Science.gov (United States)

    Plylar, Helen Bond

    Vision in vertebrates generally relies on the refractive power of the cornea and crystalline lens to facilitate vision. Light from the environment enters the eye and is refracted by the cornea and lens onto the retina for production of an image. When an animal with a system designed for air submerges underwater, the refractive power of the cornea is lost. Semi-aquatic animals (e.g., water snakes, turtles, aquatic mammals) must overcome this loss of corneal refractive power through visual accommodation. Accommodation relies on change of the position or shape of the lens to change the focal length of the optical system. Intraocular muscles and fibers facilitate lenticular displacement and deformation. Snakes, in general, are largely unstudied in terms of visual acuity and intraocular morphology. I used light microscopy and scanning electron microscopy to examine differences in eye anatomy between five sympatric colubrid snake species (Nerodia cyclopion, N. fasciata, N. rhombifer, Pantherophis obsoletus, and Thamnophis proximus) from Southeast Louisiana. I discovered previously undescribed structures associated with the lens in semi-aquatic species. Photorefractive methods were used to assess refractive error. While all species overcame the expected hyperopia imposed by submergence, there was interspecific variation in refractive error. To assess scaling of eye size with body size, I measure of eye size, head size, and body size in Nerodia cyclopion and N. fasciata from the SLU Vertebrate Museum. In both species, body size increases at a significantly faster rate than head size and eye size (negative allometry). Small snakes have large eyes relative to body size, and large snakes have relatively small eyes. There were interspecific differences in scaling of eye size with body size, where N. fasciata had larger eye diameter, but N. cyclopion had longer eyes (axial length).

  19. Comparison of supine, upright, and prone positions for liver scans

    International Nuclear Information System (INIS)

    Harolds, J.A.; Brill, A.B.; Patton, J.A.; Touya, J.J.

    1983-01-01

    We compared liver scan interpretations based on anterior images obtained in the upright, prone, and supine positions. Receiver-operating-characteristic curves were generated for three well trained observers. Results showed that reading the three different views together was more accurate than the reading of any individual image. Furthermore, interpretations based on either the prone or upright view were superior to those using the supine view alone. The prone and upright views should be used more often in liver scanning

  20. Ventilatory sensitivity to mild asphyxia: prone versus supine sleep position

    OpenAIRE

    Galland, B; Bolton, D; Taylor, B; Sayers, R; Williams, S

    2000-01-01

    AIMS—To compare the effects of prone and supine sleep position on the main physiological responses to mild asphyxia: increase in ventilation and arousal.
METHODS—Ventilatory and arousal responses to mild asphyxia (hypercapnia/hypoxia) were measured in 53 healthy infants at newborn and 3 months of age, during quiet sleep (QS) and active sleep (AS), and in supine and prone sleep positions. The asphyxial test mimicked face down rebreathing by slowly altering the inspired air: C...

  1. Supine versus upright anterior images: comparison in T1-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Jacobson, A.F.; Parker, J.A.; Royal, H.D.; Silverman, K.J.; Gervino, E.V.; Kolodny, G.M.

    1987-01-01

    In patients undergoing exercise thallium-201 myocardial scintigraphy, activity in the inferior wall on anterior images may appear diminished when the standard supine view is used, but normal when the view is acquired with the patient upright. To determine the clinical significance of this observation, the distribution of thallium-201 activity was semiquantitatively assessed in supine and upright anterior images obtained immediately after exercise in 93 patients (65 men, 28 women). The presence of inferior wall and coronary artery disease was established with coronary angiography or from documentation of previous myocardial infarction. Supine and upright images were compared with use of receiver operating characteristic curves. In male patients diagnostic accuracy for identification of both inferior wall and coronary artery disease was improved through the use of the upright anterior image. In women, there was no significant difference in reader performance with upright and supine images. Upright anterior images should be routinely obtained in men in order to reduce the frequency of false-positive identification of inferior wall defects

  2. Dynamic representations of human body movement.

    Science.gov (United States)

    Kourtzi, Z; Shiffrar, M

    1999-01-01

    Psychophysical and neurophysiological studies suggest that human body motions can be readily recognized. Human bodies are highly articulated and can move in a nonrigid manner. As a result, we perceive highly dissimilar views of the human form in motion. How does the visual system integrate multiple views of a human body in motion so that we can perceive human movement as a continuous event? The results of a set of priming experiments suggest that motion can readily facilitate the linkage of different views of a moving human. Positive priming was found for novel views of a human body that fell within the path of human movement. However, no priming was observed for novel views outside the path of motion. Furthermore, priming was restricted to those views that satisfied the biomechanical constraints of human movement. These results suggest that visual representation of human movement may be based upon the movement limitations of the human body and may reflect a dynamic interaction of motion and object-recognition processes.

  3. Metabolite-cycled STEAM and semi-LASER localization for MR spectroscopy of the human brain at 9.4T.

    Science.gov (United States)

    Giapitzakis, Ioannis-Angelos; Shao, Tingting; Avdievich, Nikolai; Mekle, Ralf; Kreis, Roland; Henning, Anke

    2018-04-01

    Metabolite cycling (MC) is an MRS technique for the simultaneous acquisition of water and metabolite spectra that avoids chemical exchange saturation transfer effects and for which water may serve as a reference signal or contain additional information in functional or diffusion studies. Here, MC was developed for human investigations at ultrahigh field. MC-STEAM and MC-semi-LASER are introduced at 9.4T with an optimized inversion pulse and elaborate coil setup. Experimental and simulation results are given for the implementation of adiabatic inversion pulses for MC. The two techniques are compared, and the effect of frequency and phase correction based on the MC water spectra is evaluated. Finally, absolute quantification of metabolites is performed. The proposed coil configuration results in a maximum B1 + of 48 μΤ in a voxel within the occipital lobe. Frequency and phase correction of single acquisitions improve signal-to-noise ratio (SNR) and linewidth, leading to high-resolution spectra. The improvement of SNR of N-acetylaspartate (SNR NAA ) for frequency aligned data, acquired with MC-STEAM and MC-semi-LASER, are 37% and 30%, respectively (P < 0.05). Moreover, a doubling of the SNR NAA for MC-semi-LASER in comparison with MC-STEAM is observed (P < 0.05). Concentration levels for 18 metabolites from the human occipital lobe are reported, as acquired with both MC-STEAM and MC-semi-LASER. This work introduces a novel methodology for single-voxel MRS on a 9.4T whole-body scanner and highlights the advantages of semi-LASER compared to STEAM in terms of excitation profile. In comparison with MC-STEAM, MC-semi-LASER yields spectra with higher SNR. Magn Reson Med 79:1841-1850, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  4. Comparison of upright LBPP and supine LBNP in terms of cardiovascular and biomechanical parameters to simulate 1/6-G (lunar gravity) and 3/8-G (Martian gravity) activities

    Science.gov (United States)

    Schlabs, Thomas; Rosales-Velderrain, Armando; Ruckstuhl, Heidi; Richardson, Sara E.; Hargens, Alan

    Background: Missions of astronauts to Moon and Mars may be planned in the future. From over 40 years of manned spaceflight it is known that the human body experiences cardiovascular and musculoskeletal losses and a decrease in aerobic fitness while exposed to reduced gravity. Because future missions will be much longer than before, further research is needed to improve Earth-based simulations of reduced gravity. Among others, two methods are capable of simu-lating fractional gravity on Earth: upright Lower Body Positive Pressure (LBPP) and supine Lower Body Negative Pressure (LBNP). No previous study has directly compared these two methods to determine which method is better suited to simulate both the biomechanical and cardiovascular responses of performing activity in lunar (1/6-G) and Martian (3/8-G) gravities. Taken previous studies into account and considering the fact that supine posture is closer to the established 10 head-up-tilt lunar simulation, we hypothesized that exercise performed in supine LBNP better simulates the cardiovascular conditions that occur in lunar and Martian gravities. Methods: 12 healthy normal subjects underwent a protocol consisting of resting and walking (0.25 Froude) with LBNP and LBPP. Each protocol was performed in simulated 1/6-G and 3/8-G. Heart-rate (HR), blood pressure, oxygen consumption (VO2), vertical component of the ground reaction force, comfort of the subject and perceived exertion of the subject (Borg Scale) were assessed. The obtained parameters were compared to predicted values for lunar and Martian gravity conditions in order to determine the method that shows the best level of agreement. Results: There was no difference in gait parameters between LBPP and LBNP simulation of lunar and Martian gravity (cadence: P=0.427, normalized stride length: P=0.373, duty fac-tor: P=0.302, and normalized vertical peak force (P=0.064). Mean blood pressure (P=0.398), comfort (P=0.832) and BORG rating (P=0.186) did not differ

  5. The relationship between doses to human body organs and exposure in a cloud of gamma emitting nuclides

    International Nuclear Information System (INIS)

    Clarke, R.H.

    1976-10-01

    Monte Carlo computer techniques were recently developed in USA to derive the photon spectrum in a semi-infinite cloud of monoenergetic photon source of uniform concentration and the dose to human body organs was estimated computationally using further Monte Carlo techniques. These results are used here to derive the exposure to be expected from a cloud emitting monoenergetic photons at discrete energies between 0.01 and 4 MeV. The exposure contributions from scattered and unscattered photon fluxes are identified at each energy and the total exposure is related to doses in a range of human body organs. It is intended to use these values of rads per Roentgen to convert the exposures calculated by the reactor safety analysis code WEERIE and those derived from environmental measurements of known airborne discharges (e.g. 41 Ar, 85 Kr, 133 Xe) into doses to human body organs. (author)

  6. Physics of the human body

    CERN Document Server

    Herman, Irving P

    2016-01-01

    This book comprehensively addresses the physics and engineering aspects of human physiology by using and building on first-year college physics and mathematics. Topics include the mechanics of the static body and the body in motion, the mechanical properties of the body, muscles in the body, the energetics of body metabolism, fluid flow in the cardiovascular and respiratory systems, the acoustics of sound waves in speaking and hearing, vision and the optics of the eye, the electrical properties of the body, and the basic engineering principles of feedback and control in regulating all aspects of function. The goal of this text is to clearly explain the physics issues concerning the human body, in part by developing and then using simple and subsequently more refined models of the macrophysics of the human body. Many chapters include a brief review of the underlying physics. There are problems at the end of each chapter; solutions to selected problems are also provided. This second edition enhances the treat...

  7. Bilateral human-robot control for semi-autonomous UAV navigation

    NARCIS (Netherlands)

    Wopereis, Han Willem; Fumagalli, Matteo; Stramigioli, Stefano; Carloni, Raffaella

    2015-01-01

    This paper proposes a semi-autonomous bilateral control architecture for unmanned aerial vehicles. During autonomous navigation, a human operator is allowed to assist the autonomous controller of the vehicle by actively changing its navigation parameters to assist it in critical situations, such as

  8. Influence of body position on muscle deoxy[Hb+Mb] during ramp cycle exercise.

    Science.gov (United States)

    DiMenna, Fred J; Bailey, Stephen J; Jones, Andrew M

    2010-09-30

    We used near-infrared spectroscopy (NIRS) to test the hypothesis that body position alters the sigmoidal response profile of muscle fractional O(2) extraction (estimated using deoxy[Hb+Mb]) during incremental cycle exercise. Seven male subjects (mean±SD age 32±13 years) completed a ramp incremental cycling test to exhaustion (30W/min) in both the supine and upright body positions. The sigmoidal (as opposed to hyperbolic) model that provided the better fit to deoxy[Hb+Mb] data during upright cycling was also present for the supine response; however, the slope of the sigmoid was increased (upright: 0.052±0.012 vs. supine: 0.090±0.036%⋅%P(peak)(-1); Prate (upright: 83±8 vs. supine: 68±19%P(peak)(-1); Pchanges occurred in the absence of a leftward shift of the sigmoid. We also found a significantly greater deltaV(O)₂/deltaW slope above compared to below gas exchange threshold (GET) for both conditions (upright: 9.8±0.5 vs. 8.2±0.9; supine: 10.7±0.9 vs. 8.0±0.8) and for supine compared to upright cycling above GET. These findings suggest that the supine posture affects O₂ extraction and V(O)₂ kinetics to a greater extent as work rate progresses during ramp incremental exercise. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Effect of scanning in the supine and prone positions on dilation of air-charged colon in CTVC

    International Nuclear Information System (INIS)

    Ye Jing; Chen Junkun; Zhang Zongjun; Wang Junpeng; Gao Dazhi

    2003-01-01

    Objective: To evaluate the effect of scanning in the supine and prone positions on dilation of air-charged colon in CT virtual colonoscopy (CTVC). Methods: Thirty cases underwent CTVC scanning in both the supine and prone positions immediately before colonoscopy, and the dilation of each intestine was graded. The differences of colon dilation in different positions were compared. Results: In supine and prone position, there were 26 (17.3%) and 22 (14.7%) insufficient dilating colon segments, respectively, and only 5 (3.3%) insufficient dilating colon segments in double positions. 15(50.0%) and 13(43.3%) colons dilated insufficiently in supine and prone position, respectively, and decreased to 5 (16.7%) in double positions. The dilation of rectum, sigmoid colon, and transverse colon had significant difference in different positions. Conclusion: When performing CTVC, it is highly necessary to scan in both the supine and prone positions in order to ensure the sufficient dilation of colon. In supine position, the dilation of transverse colon is better, while the dilation of rectum and sigmoid colon in prone position is superior to that in supine position

  10. Supine or prone position for mini-PNL procedure: does it matter.

    Science.gov (United States)

    Tokatlı, Zafer; Gokce, Mehmet Ilker; Süer, Evren; Sağlam, Remzi

    2015-06-01

    In this study it is aimed to compare the success and complication rates of mini-PNL procedure in supine and prone positions. In this retrospective study data of 180 patients treated with MPNL either in supine (n = 54) or prone (n = 126) positions between May 2009 and August 2014 was investigated. Success was defined as no visible stones >2 mm. Perioperative complications were classified using the modified Clavien system. Groups were compared with Chi square test or Student t test and for statistical significance p value of 0.05 was accepted. Mean age of the population was 42.5 ± 8.2 years and mean stone size was 23.9 ± 4.1 mm. The two groups were similar with regard to demographic characteristics and stone related characteristics except the ASA status. Success rates of the supine and prone groups were 85.1 and 87.3%, respectively (p = 0.701). No statistically significant differences in terms of complications were observed. Mean operative time was the only parameter different between the two groups (55 vs 82 min, p = 0.001). Supine position for PNL seems to be promising and the complication and success rates are shown to be similar to the prone position with MPNL technique. The only significant benefit of this technique is shorter operative time.

  11. Proximal supination osteotomy of the first metatarsal for hallux valgus.

    Science.gov (United States)

    Yasuda, Toshito; Okuda, Ryuzo; Jotoku, Tsuyoshi; Shima, Hiroaki; Hida, Takashi; Neo, Masashi

    2015-06-01

    Risk factors for hallux valgus recurrence include postoperative round-shaped lateral edge of the first metatarsal head and postoperative incomplete reduction of the sesamoids. To prevent the occurrence of such conditions, we developed a proximal supination osteotomy of the first metatarsal. Our aim was to describe this novel technique and report the outcomes in this report. Sixty-six patients (83 feet) underwent a distal soft tissue procedure combined with a proximal supination osteotomy. After the proximal crescentic osteotomy, the proximal fragment was pushed medially, and the distal fragment was abducted, and then the distal fragment of the first metatarsal was manually supinated. Outcomes were assessed using the American Orthopaedic Foot & Ankle Society (AOFAS) score and radiographic examinations. The average follow-up duration was 34 (range, 25 to 52) months. The mean AOFAS score improved significantly from 58.0 points preoperatively to 93.8 points postoperatively (P hallux valgus and intermetatarsal angle decreased significantly from 38.6 and 18.0 degrees preoperatively to 11.0 and 7.9 degrees postoperatively, respectively (both, P hallux valgus, defined as a hallux valgus angle ≥ 25 degrees. The rates of occurrence of a positive round sign and incomplete reduction of the sesamoids significantly decreased postoperatively, which may have contributed to the low hallux valgus recurrence rates. We conclude that a proximal supination osteotomy was an effective procedure for correction of hallux valgus and can achieve a low rate of hallux valgus recurrence. Level IV, retrospective case series. © The Author(s) 2015.

  12. VALIDITY AND REPRODUCIBILITY OF MEASURING THE KINEMATIC COUPLING BEHAVIOR OF CALCANEAL PRONATION/SUPINATION AND SHANK ROTATION DURING WEIGHT BEARING USING AN OPTICAL THREE-DIMENSIONAL MOTION ANALYSIS SYSTEM

    Directory of Open Access Journals (Sweden)

    Masahiro Edo

    2017-12-01

    Full Text Available Background: It’s important to understand the kinematic coupling of calcaneus and shank to optimize the pathological movement of the lower extremity. However, the quantitative indicator to show the kinematic coupling hasn’t been clarified. We measured the angles of calcaneal pronation-to-supination and shank rotation during pronation and supination of both feet in standing position and devised a technique to quantify the kinematic coupling behavior of calcaneal pronation/supination and shank rotation as the linear regression coefficient (kinematic chain ratio: KCR of those measurements. Therefore, we verified the validity and reproducibility of this technique. Methods: This study is a non-comparative cross-sectional study. The KCR, which is an outcome, was measured using an optical three-dimensional motion analysis system in 10 healthy subjects. The coefficient of determination (R² was calculated for the linear regression equation of the angle of calcaneal pronation-to-supination and angle of shank rotation, and the intraclass correlation coefficient (ICC [1,1] was calculated for the KCR during foot pronation and foot supination and for the KCR measured on different days. And also, skin movement artifacts were investigated by measurement of the displacement of bone and body surface markers in one healthy subject. Results: The linear regression equation of calcaneal pronation/supination and the angle of shank rotation included R²≥0.9 for all subjects. The KCR on foot pronation and supination had an ICC(1,1 of 0.95. The KCR measured on different days had an ICC(1,1 of 0.72. Skin movement artifacts were within the allowable range. Conclusion: The validity and reproducibility of this technique were largely good, and the technique can be used to quantify kinematic coupling behavior.

  13. Effect of supine exercise on platelet aggregation and fibrinolytic activity

    DEFF Research Database (Denmark)

    Dag, B; Fornitz, Gitte Gleerup; Bak, A M

    1994-01-01

    In 12 healthy young men, strenuous cycling exercise in the supine position, caused platelet aggregability to decrease and the ADP threshold to rise from 7.0 microM resting, to 9.5 exercising (P ... from 178 to 68 min, PAI-1 fell from 8.91 to 5.16 IU ml-1, and t-PA rose from 0.56 to 3.95 IU ml-1, all three values were significant to P exercise, it did not increase platelet activity as expected, but caused a modest increase...... of fibrinolytic activity. These results suggest that supine exercise will not affect the haemostatic system adversely....

  14. Origins and early development of human body knowledge.

    Science.gov (United States)

    Slaughter, Virginia; Heron, Michelle

    2004-01-01

    As a knowable object, the human body is highly complex. Evidence from several converging lines of research, including psychological studies, neuroimaging and clinical neuropsychology, indicates that human body knowledge is widely distributed in the adult brain, and is instantiated in at least three partially independent levels of representation. Sensorimotor body knowledge is responsible for on-line control and movement of one's own body and may also contribute to the perception of others' moving bodies; visuo-spatial body knowledge specifies detailed structural descriptions of the spatial attributes of the human body; and lexical-semantic body knowledge contains language-based knowledge about the human body. In the first chapter of this Monograph, we outline the evidence for these three hypothesized levels of human body knowledge, then review relevant literature on infants' and young children's human body knowledge in terms of the three-level framework. In Chapters II and III, we report two complimentary series of studies that specifically investigate the emergence of visuo-spatial body knowledge in infancy. Our technique is to compare infants'responses to typical and scrambled human bodies, in order to evaluate when and how infants acquire knowledge about the canonical spatial layout of the human body. Data from a series of visual habituation studies indicate that infants first discriminate scrambled from typical human body picture sat 15 to 18 months of age. Data from object examination studies similarly indicate that infants are sensitive to violations of three-dimensional human body stimuli starting at 15-18 months of age. The overall pattern of data supports several conclusions about the early development of human body knowledge: (a) detailed visuo-spatial knowledge about the human body is first evident in the second year of life, (b) visuo-spatial knowledge of human faces and human bodies are at least partially independent in infancy and (c) infants' initial

  15. Phages in the Human Body.

    Science.gov (United States)

    Navarro, Ferran; Muniesa, Maite

    2017-01-01

    Bacteriophages, viruses that infect bacteria, have re-emerged as powerful regulators of bacterial populations in natural ecosystems. Phages invade the human body, just as they do other natural environments, to such an extent that they are the most numerous group in the human virome. This was only revealed in recent metagenomic studies, despite the fact that the presence of phages in the human body was reported decades ago. The influence of the presence of phages in humans has yet to be evaluated; but as in marine environments, a clear role in the regulation of bacterial populations could be envisaged, that might have an impact on human health. Moreover, phages are excellent vehicles of genetic transfer, and they contribute to the evolution of bacterial cells in the human body by spreading and acquiring DNA horizontally. The abundance of phages in the human body does not pass unnoticed and the immune system reacts to them, although it is not clear to what extent. Finally, the presence of phages in human samples, which most of the time is not considered, can influence and bias microbiological and molecular results; and, in view of the evidences, some studies suggest that more attention needs to be paid to their interference.

  16. Discrete-time semi-Markov modeling of human papillomavirus persistence

    Science.gov (United States)

    Mitchell, C. E.; Hudgens, M. G.; King, C. C.; Cu-Uvin, S.; Lo, Y.; Rompalo, A.; Sobel, J.; Smith, J. S.

    2011-01-01

    Multi-state modeling is often employed to describe the progression of a disease process. In epidemiological studies of certain diseases, the disease state is typically only observed at periodic clinical visits, producing incomplete longitudinal data. In this paper we consider fitting semi-Markov models to estimate the persistence of human papillomavirus (HPV) type-specific infection in studies where the status of HPV type(s) is assessed periodically. Simulation study results are presented indicating the semi-Markov estimator is more accurate than an estimator currently used in the HPV literature. The methods are illustrated using data from the HIV Epidemiology Research Study (HERS). PMID:21538985

  17. Comparison of effect of body position, prone or supine, on the result of extracorporeal shock wave lithotripsy in patients with stones in the proximal ureter

    International Nuclear Information System (INIS)

    Zomorrodi, A.; Elahian, A.; Ghorbani, N.; Tavoosi, A.

    2007-01-01

    The aim of this study was to determine whether positioning of patient, prone or supine, plays a significant role on the treatment of stones in the proximal ureter with extracorporeal shock wave lithotripsy (ESWL). 68 patients with proximal ureteric stones underwent ESWL. The procedure was performed in the supine position in 35 (Group1) and the prone position in 33 patients (Group2). Stone-free rates, repeat ESWL rates, shocks per patient and shocks per session were compared in both groups. The mean session number per patient was 1.93+-0.82 in Group 1 and 1.88+-0.79 in Group 2 (P=0.786). The stone free rates, three months after ESWL, were 81.8% in group 1 and 82.9% in Group 2 (P=>0.05). Thus these two parameters were similar in both groups. Also, the number of shocks per session was 3066.1 +- 346.3 in Group 1 and 3148+-621.0 in Group 2. This difference was no significant (P=0.49). Our study suggests that the treatment of proximal ureteric stones with ESWL in the prone position is a safe and effective as when the patient is placed in the supine position. (author)

  18. EFFECT OF BODY POSITIONS ON INTRA OCULAR PRESSURE

    Directory of Open Access Journals (Sweden)

    Rajendra

    2015-09-01

    Full Text Available BACKGROUND: Intra Ocular Pressure (IOP can be altered by changing body position. Very few studies are available in the Indian subjects. AIM: To study the effect of changes in the body position from upright posture to supine to head down tilt of - 60 0 . MATERIALS AND M ETHODS: The study group consisted of 60 subjects, 35 boys and 25 girls in the age group of 18 to 24 years, with no ocular pathology were chosen. Independent measurements of the IOP of each eye were obtained. Keelar Pulsair air impulse tonometer was used in all the subjects for IOP measurement. IOP was measured in the department of Ophthalmology, Teaching Hospital between 10AM to 12 Noon. STATISTICAL ANALYSIS : were done using Student’s paired ‘t’ test. RESULTS: The change of IOP (Increased induced by the change of position between the means of IOP’s for the sitting and supine positions was 2.789±1.03 mm Hg of all subjects, 2.825±0.226 mm Hg in males and 2.739±0.089 mm Hg in females and between the supine and in clined - 60 ⁰ position was 4.971±0.914 mm Hg of all subjects, 4.703±0.816mm Hg in males and 5.346±1.098 mm Hg in females. CONCLUSION: It is apparent that, the IOP is significantly higher in the supine than in the sitting and in the inclined than in the supin e positions. The difference was statistically significant (P<0.001.

  19. Association between CT-evaluated lumbar lordosis and features of spinal degeneration, evaluated in supine position

    Science.gov (United States)

    Kalichman, Leonid; Li, Ling; Hunter, David; Been, Ella

    2013-01-01

    Background Context Few studies have directly evaluated the association of lumbar lordosis and segmental wedging of the vertebral bodies and intervertebral disks with prevalence of spinal degenerative features. Purpose To evaluate the association of CT-evaluated lumbar lordosis, segmental wedging of the vertebral bodies and that of the intervertebral disks with various spinal degeneration features. Study design This cross-sectional study was a nested project to the Framingham Heart Study. Sample A random consecutive subset of 191 participants chosen from the 3590 participants enrolled in the Framingham Heart Study who underwent multi-detector CT to assess aortic calcification. Outcome Measures Physiologic Measures Dichotomous variables indicating the presence of intervertebral disc narrowing, facet joint osteoarthritis, spondylolysis, spondylolisthesis and spinal stenosis and density (in Hounsfield units) of multifidus and erector spinae muscles were evaluated on supine CT, as well as the lordosis angle (LA) and the wedging of the vertebral bodies and intervertebral disks. Sum of vertebral bodies wedging (ΣB) and sum of intervertebral discs wedging (ΣD) were used in analyses. Methods Mean values (±SD) of LA, ΣB and ΣD were calculated in males and females and compared using the t-test. Mean values (±SD) of LA, ΣB and ΣD in 4 age groups: 0.05) with increasing age. LA showed statistically significant association with presence of spondylolysis (OR(95%CI): 1.08(1.02–1.14)) and with density of multifidus (1.06 (1.01–1.11). as well as a marginally significant association with isthmic spondylolisthesis (1.07(1.00–1.14). ΣB showed a positive association with degenerative spondylolisthesis and disc narrowing ((1.14(1.06–1.23) and 1.04 (1.00–1.08), correspondingly), whereas ΣD showed negative one (0.93(0.87–0.98) and (0.93(0.89–0.97), correspondingly). Conclusions Significant associations were found between lumbar lordosis evaluated in supine position

  20. Dosimetric effects of the prone and supine positions on image guided localized prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Liu Bei; Lerma, Fritz A.; Patel, Shilpen; Amin, Pradip; Feng Yuanming; Yi, B.-Y.; Yu, Cedric

    2008-01-01

    Purpose: To compare target coverage and doses to rectum and bladder in IMRT of localized prostate cancer in the supine versus prone position, with the inclusion of image guidance. Materials and methods: Twenty patients with early stage localized prostate carcinoma who received external beam radiotherapy in the supine and prone positions underwent approximately 10 serial CT examinations in their respective treatment position in non-consecutive days, except for one patient who was treated prone but serially imaged supine. The prostate, bladder and rectum were contoured on all CT scans. A PTV was generated on the first scan of each patient's CT series by expanding the prostate with a 5 mm margin and an IMRT plan was created. The resultant IMRT plan was then applied to that patient's remaining serial CT scans by aligning the initial CT image set with the subsequent serial CT image sets using (1) skin marks, (2) bony anatomy and (3) center of mass of the prostate. The dosimetric results from these three alignments were compared between the supine and prone groups. To account for the uncertainties associated with prostate delineation and intra-fractional geometric changes, a fictional 'daily PTV' was generated by expanding the prostate with a 3 mm margin on each serial CT scan. Thus, a more realistic target coverage index, V95, was quantified as the fraction of the daily PTV receiving at least 95% of the prescription dose. Dose-volume measures of the organs at risk were also compared. The fraction of the daily PTV contained by the initial PTV after each alignment method was quantified on each patient's serial CT scan, and is defined as PTV overlap index. Results: As expected, alignment based on skin marks yielded unacceptable dose coverage for both groups of patients. Under bony alignment, the target coverage index, V95, was 97.3% and 93.6% for prone and supine patients (p < 0.0001), respectively. The mean PTV overlap indices were 90.7% and 84.7% for prone and supine

  1. Trunk muscle activity during different variations of the supine plank exercise

    DEFF Research Database (Denmark)

    Calatayud, Joaquin; Casaña, Jose; Martín, Fernando

    2017-01-01

    Background Exercises providing neuromuscular challenges of the spinal muscles are desired for core stability, which is important for workers with heavy manual labour as well as people recovering from back pain. Purpose This study evaluated whether using a suspended modality increases trunk muscle...... voluntary isometric contraction (MVIC). Results No differences between exercises were found for UP ABS, LOW ABS and OBLIQ muscle activity. The unilateral suspended supine plank provided the highest LUMB activity (20% of MVIC) whiles the bilateral stable supine plank provided the lowest activity (11% of MVIC...

  2. Body Size Predicts Cardiac and Vascular Resistance Effects on Men's and Women's Blood Pressure

    Directory of Open Access Journals (Sweden)

    Joyce M. Evans

    2017-08-01

    Full Text Available Key Points SummaryWe report how blood pressure, cardiac output and vascular resistance are related to height, weight, body surface area (BSA, and body mass index (BMI in healthy young adults at supine rest and standing.Much inter-subject variability in young adult's blood pressure, currently attributed to health status, may actually result from inter-individual body size differences.Each cardiovascular variable is linearly related to height, weight and/or BSA (more than to BMI.When supine, cardiac output is positively related, while vascular resistance is negatively related, to body size. Upon standing, the change in vascular resistance is positively related to size.The height/weight relationships of cardiac output and vascular resistance to body size are responsible for blood pressure relationships to body size.These basic components of blood pressure could help distinguish normal from abnormal blood pressures in young adults by providing a more effective scaling mechanism.Introduction: Effects of body size on inter-subject blood pressure (BP variability are not well established in adults. We hypothesized that relationships linking stroke volume (SV, cardiac output (CO, and total peripheral resistance (TPR with body size would account for a significant fraction of inter-subject BP variability.Methods: Thirty-four young, healthy adults (19 men, 15 women participated in 38 stand tests during which brachial artery BP, heart rate, SV, CO, TPR, and indexes of body size were measured/calculated.Results: Steady state diastolic arterial BP was not significantly correlated with any index of body size when subjects were supine. However, upon standing, the more the subject weighed, or the taller s/he was, the greater the increase in diastolic pressure. Systolic pressure strongly correlated with body weight and height both supine and standing. Diastolic and systolic BP were more strongly related to height, weight and body surface area than to body mass

  3. [Survival Strategies of Aspergillus in the Human Body].

    Science.gov (United States)

    Tashiro, Masato; Izumikawa, Koichi

    2017-01-01

     The human body is a hostile environment for Aspergillus species, which originally live outside the human body. There are lots of elimination mechanisms against Aspergillus inhaled into the human body, such as high body temperature, soluble lung components, mucociliary clearance mechanism, or responses of phagocytes. Aspergillus fumigatus, which is the primary causative agent of human infections among the human pathogenic species of Aspergillus, defend itself from the hostile human body environment by various mechanisms, such as thermotolerance, mycotoxin production, and characteristic morphological features. Here we review mechanisms of defense in Aspergillus against elimination from the human body.

  4. Biceps brachii can add to performance of tasks requiring supination in cerebral palsy patients

    NARCIS (Netherlands)

    de Bruin, M.; Veeger, H.E.J.; Kreulen, M.; Smeulders, M.J.C.; Bus, S.A.

    2013-01-01

    The aim of this study was to assess whether cerebral palsy patients can use biceps brachii for supination during movement tasks requiring supination and pronation. 3D upper extremity kinematic and EMG-data of 12 patients (mean age 13. y 8. mo. ±. 36. mo) were compared to 10 healthy age-matched

  5. Biceps brachii can add to performance of tasks requiring supination in cerebral palsy patients

    NARCIS (Netherlands)

    de Bruin, M.; Veeger, H. E. J.; Kreulen, M.; Smeulders, M. J. C.; Bus, S. A.

    2013-01-01

    The aim of this study was to assess whether cerebral palsy patients can use biceps brachii for supination during movement tasks requiring supination and pronation. 3D upper extremity kinematic and EMG-data of 12 patients (mean age 13 y 8 mo ± 36 mo) were compared to 10 healthy age-matched controls.

  6. Comparison of the kidney dose between supine and prone position for pelvic and periaortic irradiation

    International Nuclear Information System (INIS)

    Mison, Chun; Haejin, Kang; Juree, Kim; Heesuk, Ryu; Hyunsoo, Shin

    1996-01-01

    We compared the doses received by the kidney in supine and prone positions for pelvic and periaortic irradiation. Kidney locations were verified by CT images taken with patients in the same position as during the treatment. Due to the shift of the kidney anteriorly during prone position, treatment in supine position delivered a much lower dose to most of the kidney than treatment in the prone position. Therefore, for periaortic irradiation treatment, the supine position should be considered to minimize the dose to the kidneys, even though the prone position with a belly board can reduce the dose to the small bowel

  7. The amplitude of the Achilles tendon reflex in infants is related to body position

    NARCIS (Netherlands)

    Bruggink, Janneke L. M.; Bos, Arend F.; vd Hoeven, Johannes H.; Brouwer, Oebele F.; Sollie, Krystyna M.; Sival, Deborah A.

    2006-01-01

    In this study, we investigated whether the Achilles tendon reflex (ATR) in healthy infants is modulated by changes in body position (prone vs. supine). The amplitude of the ATR was compared at postnatal day 1, months 2, 3 and 6, while infants were placed in prone and supine position. The ATR was

  8. What is a Human Body?

    DEFF Research Database (Denmark)

    Nissen, Ulrik Becker

    2017-01-01

    The essay offers an overview of different understandings of what a body is. As such, it can be read as an overview of what we mean, when we speak of a “human body”. However, the article also goes a step further; in the last section, a responsive understanding of the human body is outlined....... This is understood as responsiveness in three ways: viz an embodied self that responds to natural life, other human beings and, ultimately, to God....

  9. Human Body Exergy Metabolism

    OpenAIRE

    Mady, Carlos Eduardo Keutenedjian

    2013-01-01

    The exergy analysis of the human body is a tool that can provide indicators of health and life quality. To perform the exergy balance it is necessary to calculate the metabolism on an exergy basis, or metabolic exergy, although there is not yet consensus in its calculation procedure. Hence, the aim of this work is to provide a general method to evaluate this physical quantity for human body based on indirect calorimetry data. To calculate the metabolism on an exergy basis it is necessary to d...

  10. Effects of upright and supine position on cardiac rest and exercise response in aortic regurgitation.

    Science.gov (United States)

    Shen, W F; Roubin, G S; Fletcher, P J; Choong, C Y; Hutton, B F; Harris, P J; Kelly, D T

    1985-02-01

    The effects of upright and supine position on cardiac response to exercise were assessed by radionuclide ventriculography in 15 patients with moderate to severe aortic regurgitation (AR) and in 10 control subjects. In patients with AR, heart rate was higher during upright exercise, but systolic and diastolic blood pressure and left ventricular (LV) output were similar during both forms of exercise. LV stroke volume and end-diastolic volume were not altered during supine exercise. LV end-systolic volume increased and ejection fraction decreased during supine exercise, but both were unchanged during upright exercise. Of 15 patients, 5 in the upright and 12 in the supine position had an abnormal LV ejection fraction response to exercise (p less than 0.01). Right ventricular ejection fraction increased and regurgitant index decreased with both forms of exercise and was not significantly different between the 2 positions. Thus, posture is important in determining LV response to exercise in patients with moderate to severe AR.

  11. Supraesophageal Reflux: Correlation of Position and Occurrence of Acid Reflux-Effect of Head-of-Bed Elevation on Supine Reflux.

    Science.gov (United States)

    Scott, David R; Simon, Ronald A

    2015-01-01

    Supraesophageal reflux of gastric contents can contribute to perennial nasopharyngitis, cough, and asthma. However, effective treatment strategies for supraesophageal reflux disease (SERD) remain inadequately defined. The purpose of this study is to assess the prevalence and timing of SERD and to investigate the efficacy of head-of-bed elevation in its treatment. A retrospective chart review of patients seen at Scripps Clinic Division of Allergy, Asthma and Immunology was performed who had undergone overnight nasopharyngeal pH monitoring with a commercially available nasopharyngeal pH-monitoring device, Dx-pH Measurement System from Restech, San Diego, Calif. Subjects with reflux were classified based on the position of reflux as either supine only, upright only, or both supine and upright. In a subset of subjects with supine-only reflux, pH monitoring was compared before and after elevating the head of bed 6 inches. Adequate nasopharyngeal pH-monitoring data were obtained for 235 patients. Reflux was detected in 113 (48%) patients. The pattern of reflux observed was 62 (55%) supine only, 4 (4%) upright only, and 47 (42%) upright and supine. Sequential overnight nasopharyngeal pH monitoring before and after head-of-bed elevation was obtained in 13 individuals with supine-only reflux. Ten subjects demonstrated significant improvement, 8 of whom demonstrated complete resolution of supine reflux with 6 inches of head-of-bed elevation. This study provides new evidence that SERD frequently occurs in the supine position and that 6 inches of head-of-bed elevation is effective in reducing supine SERD. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  12. Body position-dependent shift in odor percept present only for perithreshold odors.

    Science.gov (United States)

    Lundström, Johan N; Boyle, Julie A; Jones-Gotman, Marilyn

    2008-01-01

    We recently demonstrated that a supine position causes a decrease in olfactory sensitivity compared with an upright position. We pursued that initial finding in 3 separate experiments in which we explored the extent of, and mechanism underlying, this phenomenon. In Experiment 1, we replicated the decrease in olfactory sensitivity when in a supine compared with an upright position. In Experiment 2, we measured body position-dependent shifts in physiological variables and sniff measures while smelling suprathreshold odorants and performing a perithreshold odor intensity discrimination task. Olfactory performances were reduced while supine. However, no relationships between the shift in olfactory performances and either the physiological variables or sniff measures were found. In Experiment 3, we determined that there were no position-dependent shifts in ability to discriminate or identify suprathreshold odors or rate them for pleasantness, intensity, or familiarity. However, a drop in scores was observed, and performance was slowed, on a cognitive skill while supine. These results demonstrate a body position-dependent shift in olfactory sensitivity only for perithreshold odors that appears to be mediated by cognitive rather than physiological factors. Implications for olfactory imaging studies are discussed.

  13. ECIRS (Endoscopic Combined Intrarenal Surgery) in the Galdakao-modified supine Valdivia position: a new life for percutaneous surgery?

    Science.gov (United States)

    Cracco, Cecilia Maria; Scoffone, Cesare Marco

    2011-12-01

    Percutaneous nephrolithotomy (PNL) is still the gold-standard treatment for large and/or complex renal stones. Evolution in the endoscopic instrumentation and innovation in the surgical skills improved its success rate and reduced perioperative morbidity. ECIRS (Endoscopic Combined IntraRenal Surgery) is a new way of affording PNL in a modified supine position, approaching antero-retrogradely to the renal cavities, and exploiting the full array of endourologic equipment. ECIRS summarizes the main issues recently debated about PNL. The recent literature regarding supine PNL and ECIRS has been reviewed, namely about patient positioning, synergy between operators, procedures, instrumentation, accessories and diagnostic tools, step-by-step standardization along with versatility of the surgical sequence, minimization of radiation exposure, broadening to particular and/or complex patients, limitation of post-operative renal damage. Supine PNL and ECIRS are not superior to prone PNL in terms of urological results, but guarantee undeniable anesthesiological and management advantages for both patient and operators. In particular, ECIRS requires from the surgeon a permanent mental attitude to synergy, standardized surgical steps, versatility and adherence to the ongoing clinical requirements. ECIRS can be performed also in particular cases, irrespective to age or body habitus. The use of flexible endoscopes during ECIRS contributes to minimizing radiation exposure, hemorrhagic risk and post-PNL renal damage. ECIRS may be considered an evolution of the PNL procedure. Its proposal has the merit of having triggered the critical analysis of the various PNL steps and of patient positioning, and of having transformed the old static PNL into an updated approach.

  14. Human body segmentation via data-driven graph cut.

    Science.gov (United States)

    Li, Shifeng; Lu, Huchuan; Shao, Xingqing

    2014-11-01

    Human body segmentation is a challenging and important problem in computer vision. Existing methods usually entail a time-consuming training phase for prior knowledge learning with complex shape matching for body segmentation. In this paper, we propose a data-driven method that integrates top-down body pose information and bottom-up low-level visual cues for segmenting humans in static images within the graph cut framework. The key idea of our approach is first to exploit human kinematics to search for body part candidates via dynamic programming for high-level evidence. Then, by using the body parts classifiers, obtaining bottom-up cues of human body distribution for low-level evidence. All the evidence collected from top-down and bottom-up procedures are integrated in a graph cut framework for human body segmentation. Qualitative and quantitative experiment results demonstrate the merits of the proposed method in segmenting human bodies with arbitrary poses from cluttered backgrounds.

  15. Influence of heart rate in nonlinear HRV indices as a sampling rate effect evaluated on supine and standing

    Directory of Open Access Journals (Sweden)

    Juan Bolea

    2016-11-01

    Full Text Available The purpose of this study is to characterize and attenuate the influence of mean heart rate (HR on nonlinear heart rate variability (HRV indices (correlation dimension, sample and approximate entropy as a consequence of being the HR the intrinsic sampling rate of HRV signal. This influence can notably alter nonlinear HRV indices and lead to biased information regarding autonomic nervous system (ANS modulation.First, a simulation study was carried out to characterize the dependence of nonlinear HRV indices on HR assuming similar ANS modulation. Second, two HR-correction approaches were proposed: one based on regression formulas and another one based on interpolating RR time series. Finally, standard and HR-corrected HRV indices were studied in a body position change database.The simulation study showed the HR-dependence of non-linear indices as a sampling rate effect, as well as the ability of the proposed HR-corrections to attenuate mean HR influence. Analysis in a body position changes database shows that correlation dimension was reduced around 21% in median values in standing with respect to supine position (p < 0.05, concomitant with a 28% increase in mean HR (p < 0.05. After HR-correction, correlation dimension decreased around 18% in standing with respect to supine position, being the decrease still significant. Sample and approximate entropy showed similar trends.HR-corrected nonlinear HRV indices could represent an improvement in their applicability as markers of ANS modulation when mean HR changes.

  16. Human cerebral venous outflow pathway depends on posture and central venous pressure

    Science.gov (United States)

    Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348

  17. Human body may produce bacteria.

    Science.gov (United States)

    Salerian, Alen J

    2017-06-01

    "Human body may produce bacteria" proposes that human body may produce bacteria and represent an independent source of infections contrary to the current paradigm of infectious disorders proposed by Louis Pasteur in 1880. The following observations are consistent with this hypothesis: A. Bidirectional transformations of both living and nonliving things have been commonly observed in nature. B. Complex multicellular organisms harbor the necessary properties to produce bacteria (water, nitrogen and oxygen). C. Physical laws suggest any previously observed phenomenon or action will occur again (life began on earth; a non living thing). D. Animal muscle cells may generate energy (fermentation). E. Sterilized food products (i.e. boiled eggs), may produce bacteria and fungus under special conditions and without any exposure to foreign living cells. "Human body may produce bacteria" may challenge the current medical paradigm that views human infectious disorders as the exclusive causative byproducts of invading foreign cells. It may also introduce new avenues to treat infectious disorders. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Supine proton beam craniospinal radiotherapy using a novel tabletop adapter

    International Nuclear Information System (INIS)

    Buchsbaum, Jeffrey C.; Besemer, Abby; Simmons, Joseph; Hoene, Ted; Simoneaux, Victor; Sandefur, Amy; Wolanski, Mark; Li, Zhao; Cheng, Chee-Wei

    2013-01-01

    To develop a device that allows supine craniospinal proton and photon therapy to the vast majority of proton and photon facilities currently experiencing limitations as a result of couch design issues. Plywood and carbon fiber were used for the development of a prototype unit. Once this was found to be satisfactory after all design issues were addressed, computer-assisted design (CAD) was used and carbon fiber tables were built to our specifications at a local manufacturer of military and racing car carbon fiber parts. Clinic-driven design was done using real-time team discussion for a prototype design. A local machinist was able to construct a prototype unit for us in <2 weeks after the start of our project. Once the prototype had been used successfully for several months and all development issues were addressed, a custom carbon fiber design was developed in coordination with a carbon fiber manufacturer in partnership. CAD methods were used to design the units to allow oblique fields from head to thigh on patients up to 200 cm in height. Two custom-designed carbon fiber craniospinal tabletop designs now exist: one long and one short. Four are in successful use in our facility. Their weight tolerance is greater than that of our robot table joint (164 kg). The long unit allows for working with taller patients and can be converted into a short unit as needed. An affordable, practical means of doing supine craniospinal therapy with protons or photons can be used in most locations via the use of these devices. This is important because proton therapy provides a much lower integral dose than all other therapy methods for these patients and the supine position is easier for patients to tolerate and for anesthesia delivery. These units have been successfully used for adult and pediatric supine craniospinal therapy, proton therapy using oblique beams to the low pelvis, treatment of various spine tumors, and breast-sparing Hodgkin's therapy

  19. Supine proton beam craniospinal radiotherapy using a novel tabletop adapter

    Energy Technology Data Exchange (ETDEWEB)

    Buchsbaum, Jeffrey C., E-mail: jbuchsba@iupui.edu [IU Health Proton Therapy Center, Bloomington, IN (United States); Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States); Department of Pediatrics, Indiana University School of Medicine, Indianapolis, IN (United States); Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, IN (United States); Besemer, Abby; Simmons, Joseph; Hoene, Ted; Simoneaux, Victor; Sandefur, Amy [IU Health Proton Therapy Center, Bloomington, IN (United States); Wolanski, Mark; Li, Zhao; Cheng, Chee-Wei [IU Health Proton Therapy Center, Bloomington, IN (United States); Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States)

    2013-04-01

    To develop a device that allows supine craniospinal proton and photon therapy to the vast majority of proton and photon facilities currently experiencing limitations as a result of couch design issues. Plywood and carbon fiber were used for the development of a prototype unit. Once this was found to be satisfactory after all design issues were addressed, computer-assisted design (CAD) was used and carbon fiber tables were built to our specifications at a local manufacturer of military and racing car carbon fiber parts. Clinic-driven design was done using real-time team discussion for a prototype design. A local machinist was able to construct a prototype unit for us in <2 weeks after the start of our project. Once the prototype had been used successfully for several months and all development issues were addressed, a custom carbon fiber design was developed in coordination with a carbon fiber manufacturer in partnership. CAD methods were used to design the units to allow oblique fields from head to thigh on patients up to 200 cm in height. Two custom-designed carbon fiber craniospinal tabletop designs now exist: one long and one short. Four are in successful use in our facility. Their weight tolerance is greater than that of our robot table joint (164 kg). The long unit allows for working with taller patients and can be converted into a short unit as needed. An affordable, practical means of doing supine craniospinal therapy with protons or photons can be used in most locations via the use of these devices. This is important because proton therapy provides a much lower integral dose than all other therapy methods for these patients and the supine position is easier for patients to tolerate and for anesthesia delivery. These units have been successfully used for adult and pediatric supine craniospinal therapy, proton therapy using oblique beams to the low pelvis, treatment of various spine tumors, and breast-sparing Hodgkin's therapy.

  20. The possibility of access to the kidneys from posterior axillary line in supine position for percutaneous nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Ali Tabibi

    2013-11-01

    Full Text Available Please cite this article as: Tabibi A, Kashi AH, Mirjalili SAM, Mahmoudnejad N, Kashani P, Salavatipour B, Soltani MH. The possibility of access to the kidneys from posterior axillary line in supine position for percutaneous nephrolithotomy. Novel Biomed 2013;1(2:43-47.Objectives: To evaluate the possibility of access to the kidneys from posterior axillary line (PAL in supine position for percutaneous nephrolithotomy.Materials and Methods: 102 consecutive patients who were candidated for abdominal CT scan, enrolled in this study. In cases of impossible access, the point on the posterior surface of body which permitted safe access was determined and the percent of movement toward body midline (relative to PAL was calculated (M.PER.Results: Percutaneous access was simulated from upper and middle calyces of the kidney in 13% and 75% of cases, respectively. Access to the lower region was possible in 90% of right and 79% of left lower calyces, respectively (p=0.03. In cases with impossible access from PAL, the M.PER for a safe access was 46-47% for upper region and 34- 38% for middle and lower calyces of the kidney (P = 0.0001.Conclusions: Access to upper calyces from PAL was limited in some cases regarding to the presence of solid organs. Presence of colon made access impossible in the lower right and left calyces in about 10% and 20% of cases, respectively. In upper region, more deviation toward midline was necessary to establish a safe access compared with middle and lower calyces.

  1. Supine Percutaneous Nephrolithotripsy in Double-S Position.

    Science.gov (United States)

    Giusti, Giuseppe; De Lisa, Antonello

    2018-01-01

    At present, the percutaneous nephrolithotripsy (PCNL) is performed both in supine and in prone position. The aim of this paper is to describe an innovative position during PCNL. We describe a supine position. The patient's legs are slightly abducted at the hips. The thorax is laterally tilted (inclination 30°-35°) and kept in the right position by one or two gel pads placed between the scapula and the vertebrae. External genitalia can be accessed at any time, so that it is always possible to use flexible instruments in the upper urinary tract. We used this position for a period of 12 months to treat with PCNL 45 patients with renal lithiasis. All the procedures were successfully completed without complications, using the position we are describing. The following are some of its benefits: an easier positioning of the patient; a better exposure of the flank for an easier access to the posterior renal calyces of the kidney; a lower risk of pressure injuries compared to positions foreseeing the use of knee crutches; the possibility of combined procedures (ECIRS) through the use of flexible instruments; and a good fluoroscopic visualization of the kidney not overlapped by the vertebrae. This position is effective, safe, easy, and quick to prepare and allows for combined anterograde/retrograde operations.

  2. On scaling of human body models

    Directory of Open Access Journals (Sweden)

    Hynčík L.

    2007-10-01

    Full Text Available Human body is not an unique being, everyone is another from the point of view of anthropometry and mechanical characteristics which means that division of the human body population to categories like 5%-tile, 50%-tile and 95%-tile from the application point of view is not enough. On the other hand, the development of a particular human body model for all of us is not possible. That is why scaling and morphing algorithms has started to be developed. The current work describes the development of a tool for scaling of the human models. The idea is to have one (or couple of standard model(s as a base and to create other models based on these basic models. One has to choose adequate anthropometrical and biomechanical parameters that describe given group of humans to be scaled and morphed among.

  3. Effect of Pelvic Tilt and Rotation on Cup Orientation in Both Supine and Standing Positions.

    Science.gov (United States)

    Yun, Hohyun; Murphy, William S; Ward, Daniel M; Zheng, Guoyan; Hayden, Brett L; Murphy, Stephen B

    2018-05-01

    The purpose of this study is to analyze the effect of pelvic tilt and rotation on radiographic measurement of cup orientation. A total of 68 patients (79 hips) were included in this study. The patients had a computed tomography study and approximately 3 months of postoperative standing anteroposterior pelvic radiographs in both supine and standing positions. We used 2-dimensional (2D)/3-dimensional (3D) matching to measure pelvic tilt and rotation, and cup orientation. There was a wide range of pelvic tilt between individuals in both supine and standing positions. Supine pelvic tilt was different from standing pelvic tilt (P cup anteversion before and after 2D/3D matching in both supine and standing positions (P cup anteversion before and after 2D/3D matching. When all 79 hips were separated into right and left side, pelvic rotation inversely correlated with the pelvic tilt-adjusted difference in anteversion before and after 2D/3D matching of the right side but directly correlated with that of the left side in both supine and standing positions. This study demonstrated that the measurement of cup anteversion on anteroposterior radiographs is significantly affected by both pelvic tilt and pelvic rotation (depending on the side). Improved understanding of pelvic orientation and improved ability to measure pelvic orientation may eventually allow for desired cup positioning to potentially protect against complications associated with malposition of the cup. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Light bodies in human pituitary adenomas

    DEFF Research Database (Denmark)

    Holck, S; Wewer, U M; Albrechtsen, R

    1987-01-01

    Light bodies are large cytoplasmic granules originally described in the gonadotrophic cells of the rat pituitary gland. In order to determine whether similar bodies occur in the human anterior pituitary gland, 89 pituitary adenomas and periadenomatous tissue from 20 cases were examined...... cells in periadenomatous tissue from 20 cases. These results show that some human pituitary adenomas may contain light bodies identical to those seen in gonadotrophs of rat pituitary....... by transmission electron microscopy. Double membrane bound bodies with filamentous internal structure identical to rodent light bodies were identified in 10 hormone-producing adenomas: 5 PRL, 1 PRL-GH, 2 GH, and 2 ACTH-producing tumours. No light bodies were found in the remaining 79 tumours nor in the pituitary...

  5. Electrical stimulation of human lower extremities enhances energy consumption, carbohydrate oxidation, and whole body glucose uptake.

    Science.gov (United States)

    Hamada, Taku; Hayashi, Tatsuya; Kimura, Tetsuya; Nakao, Kazuwa; Moritani, Toshio

    2004-03-01

    Our laboratory has recently demonstrated that low-frequency electrical stimulation (ES) of quadriceps muscles alone significantly enhanced glucose disposal rate (GDR) during euglycemic clamp (Hamada T, Sasaki H, Hayashi T, Moritani T, and Nakao K. J Appl Physiol 94: 2107-2112, 2003). The present study is further follow-up to examine the acute metabolic effects of ES to lower extremities compared with voluntary cycle exercise (VE) at identical intensity. In eight male subjects lying in the supine position, both lower leg (tibialis anterior and triceps surae) and thigh (quadriceps and hamstrings) muscles were sequentially stimulated to cocontract in an isometric manner at 20 Hz with a 1-s on-off duty cycle for 20 min. Despite small elevation of oxygen uptake by 7.3 +/- 0.3 ml x kg(-1) x min(-1) during ES, the blood lactate concentration was significantly increased by 3.2 +/- 0.3 mmol/l in initial period (5 min) after the onset of the ES (P increased anaerobic glycolysis by ES. Furthermore, whole body glucose uptake determined by GDR during euglycemic clamp demonstrated a significant increase during and after the cessation of ES for at least 90 min (P energy consumption, carbohydrate oxidation, and whole body glucose uptake at low intensity of exercise. Percutaneous ES may become a therapeutic utility to enhance glucose metabolism in humans.

  6. The retrorenal colon in the supine and prone patient

    International Nuclear Information System (INIS)

    Hopper, K.D.; Sherman, J.L.; Luethke, J.M.; Ghaed, N.

    1986-01-01

    Ninety patients underwent CT in both supine and prone positions so that the orientation of the retroperitoneal colon about the kidneys could be determined. Particular attention was given to bowel found posterior to the kidneys, the so-called retrorenal colon. The frequency of retrorenal colon increased from 1.9% on supine studies to 10.7% on prone studies. Since most invasive renal procedures performed with the patient prone would miss retrorenal colon located behind the lateral one third of the kidney, the data were reevaluated, excluding these patients. The resulting frequency of significant retrorenal colon found on prone studies was 4.7%. Significant retrorenal colon was found exclusively at the level of the lower renal poles, and the involved colon in these patients was extensively distended with gas. Particular attention should be given, under fluoroscopic guidance, to detecting this unusual posteriorly positioned, air-filled colon before one undertakes any invasive renal procedure

  7. Video-assisted thoracic surgery for superior posterior mediastinal neurogenic tumour in the supine position

    Directory of Open Access Journals (Sweden)

    Darlong Laleng

    2009-01-01

    Full Text Available Video-assisted thoracic surgery (VATS for a superior posterior mediastinal lesion is routinely done in the lateral decubitus position similar to a standard thoracotomy using a double-lumen endotracheal tube for one-lung ventilation. This is an area above the level of the pericardium, with the superior thoracic opening as its superior limit and its inferior limit at the plane from the sternal angle to the level of intervertebral disc of thoracic 4 to 5 vertebra lying behind the great vessels. The lateral decubitus position has disadvantages of the double-lumen endotracheal tube getting malpositioned during repositioning from supine position to the lateral decubitus position, shoulder injuries due to the prolonged abnormal fixed posture and rarer injuries of the lower limb. There is no literature related to VATS in the supine position for treating lesions in the posterior mediastinum because the lung tissue falls in the dependent posterior mediastinum and obscures the field of surgery; however, VATS in the supine position is routinely done for lesions in the anterior mediastinum and single-stage bilateral spontaneous pneumothorax. Thus, in the selected cases, ′VATS in supine position′ allows an invasive procedure to be completed in the most stable anatomical posture.

  8. A modular approach to numerical human body modeling

    NARCIS (Netherlands)

    Forbes, P.A.; Griotto, G.; Rooij, L. van

    2007-01-01

    The choice of a human body model for a simulated automotive impact scenario must take into account both accurate model response and computational efficiency as key factors. This study presents a "modular numerical human body modeling" approach which allows the creation of a customized human body

  9. [Research progress on free radicals in human body].

    Science.gov (United States)

    Wang, Q B; Xu, F P; Wei, C X; Peng, J; Dong, X D

    2016-08-10

    Free radicals are the intermediates of metabolism, widely exist in the human bodies. Under normal circumstances, the free radicals play an important role in the metabolic process on human body, cell signal pathway, gene regulation, induction of cell proliferation and apoptosis, so as to maintain the normal growth and development of human body and to inhibit the growth of bacteria, virus and cancer. However, when organic lesion occurs affected by external factors or when equilibrium of the free radicals is tipped in the human body, the free radicals will respond integratedly with lipids, protein or nucleic acid which may jeopardize the health of human bodies. This paper summarizes the research progress of the free radicals conducted in recent years, in relations to the perspective of the types, origins, test methods of the free radicals and their relationship with human's health. In addition, the possible mechanisms of environmental pollutants (such as polycyclic aromatic hydrocarbons) mediating oxidative stress and free radicals scavenging in the body were also summarized.

  10. Study of the thermal shock between two semi-infinite bodies during ultra-fast transients

    International Nuclear Information System (INIS)

    Perret, R.

    1977-01-01

    For the heat-conduction system of two suddently-contacting semi-infinite bodies at different temperatures, the hyperbolic equation is compared with the Fourier equation. The times are reported during which the solutions differ significantly; in particular, at the initial instant of contact, the hyperbolic equation predicts a zero heat flux, while the classic equation an infinite heat flux. The temperature of contact obtained using the hyperbolic equation is used in a model of vapor explosion [fr

  11. How accurate are measurements of skin-lesion depths on prebiopsy supine chest computed tomography for transthoracic needle biopsies?

    International Nuclear Information System (INIS)

    Cheung, Joo Yeon; Kim, Yookyung; Shim, Sung Shine; Lee, Jin Hwa; Chang, Jung Hyun; Ryu, Yon Ju; Lee, Rena J.

    2012-01-01

    Aim: To evaluate the accuracy of depth measurements on supine chest computed tomography (CT) for transthoracic needle biopsy (TNB). Materials and methods: We measured skin-lesion depths from the skin surface to nodules on both prebiopsy supine CT scans and CT scans obtained during cone beam CT-guided TNB in the supine (n = 29) or prone (n = 40) position in 69 patients, and analyzed the differences between the two measurements, based on patient position for the biopsy and lesion location. Results: Skin-lesion depths measured on prebiopsy supine CT scans were significantly larger than those measured on CT scans obtained during TNB in the prone position (p < 0.001; mean difference ± standard deviation (SD), 6.2 ± 5.7 mm; range, 0–18 mm), but the differences showed marginal significance in the supine position (p = 0.051; 3.5 ± 3.9 mm; 0–13 mm). Additionally, the differences were significantly larger for the upper (mean ± SD, 7.8 ± 5.7 mm) and middle (10.1 ± 6.5 mm) lung zones than for the lower lung zones (3.1 ± 3.3 mm) in the prone position (p = 0.011), and were larger for the upper lung zone (4.6 ± 5.0 mm) than for the middle (2.4 ± 2.0 mm) and lower (2.3 ± 2.3 mm) lung zones in the supine position (p = 0.004). Conclusions: Skin-lesion depths measured on prebiopsy supine chest CT scans were inaccurate for TNB in the prone position, particularly for nodules in the upper and middle lung zones.

  12. A bacteriophages journey through the human body.

    Science.gov (United States)

    Barr, Jeremy J

    2017-09-01

    The human body is colonized by a diverse collective of microorganisms, including bacteria, fungi, protozoa and viruses. The smallest entity of this microbial conglomerate are the bacterial viruses. Bacteriophages, or phages for short, exert significant selective pressure on their bacterial hosts, undoubtedly influencing the human microbiome and its impact on our health and well-being. Phages colonize all niches of the body, including the skin, oral cavity, lungs, gut, and urinary tract. As such our bodies are frequently and continuously exposed to diverse collections of phages. Despite the prevalence of phages throughout our bodies, the extent of their interactions with human cells, organs, and immune system is still largely unknown. Phages physically interact with our mucosal surfaces, are capable of bypassing epithelial cell layers, disseminate throughout the body and may manipulate our immune system. Here, I establish the novel concept of an "intra-body phageome," which encompasses the collection of phages residing within the classically "sterile" regions of the body. This review will take a phage-centric view of the microbiota, human body, and immune system with the ultimate goal of inspiring a greater appreciation for both the indirect and direct interactions between bacteriophages and their mammalian hosts. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Functional neuronal processing of human body odors.

    Science.gov (United States)

    Lundström, Johan N; Olsson, Mats J

    2010-01-01

    Body odors carry informational cues of great importance for individuals across a wide range of species, and signals hidden within the body odor cocktail are known to regulate several key behaviors in animals. For a long time, the notion that humans may be among these species has been dismissed. We now know, however, that each human has a unique odor signature that carries information related to his or her genetic makeup, as well as information about personal environmental variables, such as diet and hygiene. Although a substantial number of studies have investigated the behavioral effects of body odors, only a handful have studied central processing. Recent studies have, however, demonstrated that the human brain responds to fear signals hidden within the body odor cocktail, is able to extract kin specific signals, and processes body odors differently than other perceptually similar odors. In this chapter, we provide an overview of the current knowledge of how the human brain processes body odors and the potential importance these signals have for us in everyday life. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. An IMU-to-Body Alignment Method Applied to Human Gait Analysis

    Directory of Open Access Journals (Sweden)

    Laura Susana Vargas-Valencia

    2016-12-01

    Full Text Available This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis.

  15. Body composition validation technique using anthropometrics ...

    African Journals Online (AJOL)

    The horizontal bodyweights of the participantsweremeasured inlying positionsusing anadaptation of theGuthri Smith apparatus frame towhich a firmstretcher and two spring balances were attached on a horizontal level position. The heights of the subjects were also taken on supine lying on a firm plinth. The body weight and ...

  16. Supine Percutaneous Nephrolithotripsy in Double-S Position

    Directory of Open Access Journals (Sweden)

    Giuseppe Giusti

    2018-01-01

    Full Text Available Background. At present, the percutaneous nephrolithotripsy (PCNL is performed both in supine and in prone position. The aim of this paper is to describe an innovative position during PCNL. Methods. We describe a supine position. The patient’s legs are slightly abducted at the hips. The thorax is laterally tilted (inclination 30°–35° and kept in the right position by one or two gel pads placed between the scapula and the vertebrae. External genitalia can be accessed at any time, so that it is always possible to use flexible instruments in the upper urinary tract. We used this position for a period of 12 months to treat with PCNL 45 patients with renal lithiasis. Results. All the procedures were successfully completed without complications, using the position we are describing. The following are some of its benefits: an easier positioning of the patient; a better exposure of the flank for an easier access to the posterior renal calyces of the kidney; a lower risk of pressure injuries compared to positions foreseeing the use of knee crutches; the possibility of combined procedures (ECIRS through the use of flexible instruments; and a good fluoroscopic visualization of the kidney not overlapped by the vertebrae. Conclusions. This position is effective, safe, easy, and quick to prepare and allows for combined anterograde/retrograde operations.

  17. Biodynamics of deformable human body motion

    Science.gov (United States)

    Strauss, A. M.; Huston, R. L.

    1976-01-01

    The objective is to construct a framework wherein the various models of human biomaterials fit in order to describe the biodynamic response of the human body. The behavior of the human body in various situations, from low frequency, low amplitude vibrations to impact loadings in automobile and aircraft crashes, is very complicated with respect to all aspects of the problem: materials, geometry and dynamics. The materials problem is the primary concern, but the materials problem is intimately connected with geometry and dynamics.

  18. Human body capacitance: static or dynamic concept? [ESD

    DEFF Research Database (Denmark)

    Jonassen, Niels M

    1998-01-01

    A standing human body insulated from ground by footwear and/or floor covering is in principle an insulated conductor and has, as such, a capacitance, i.e. the ability to store a charge and possibly discharge the stored energy in a spark discharge. In the human body, the human body capacitance (HBC...... when a substantial part of the flux extends itself through badly defined stray fields. Since the concept of human body capacitance is normally used in a static (electric) context, it is suggested that the HBC be determined by a static method. No theoretical explanation of the observed differences...

  19. Modeling the exergy behavior of human body

    International Nuclear Information System (INIS)

    Keutenedjian Mady, Carlos Eduardo; Silva Ferreira, Maurício; Itizo Yanagihara, Jurandir; Hilário Nascimento Saldiva, Paulo; Oliveira Junior, Silvio de

    2012-01-01

    Exergy analysis is applied to assess the energy conversion processes that take place in the human body, aiming at developing indicators of health and performance based on the concepts of exergy destroyed rate and exergy efficiency. The thermal behavior of the human body is simulated by a model composed of 15 cylinders with elliptical cross section representing: head, neck, trunk, arms, forearms, hands, thighs, legs, and feet. For each, a combination of tissues is considered. The energy equation is solved for each cylinder, being possible to obtain transitory response from the body due to a variation in environmental conditions. With this model, it is possible to obtain heat and mass flow rates to the environment due to radiation, convection, evaporation and respiration. The exergy balances provide the exergy variation due to heat and mass exchange over the body, and the exergy variation over time for each compartments tissue and blood, the sum of which leads to the total variation of the body. Results indicate that exergy destroyed and exergy efficiency decrease over lifespan and the human body is more efficient and destroys less exergy in lower relative humidities and higher temperatures. -- Highlights: ► In this article it is indicated an overview of the human thermal model. ► It is performed the energy and exergy analysis of the human body. ► Exergy destruction and exergy efficiency decreases with lifespan. ► Exergy destruction and exergy efficiency are a function of environmental conditions.

  20. PF-05231023, a long-acting FGF21 analogue, decreases body weight by reduction of food intake in non-human primates.

    Science.gov (United States)

    Thompson, W Clayton; Zhou, Yingjiang; Talukdar, Saswata; Musante, Cynthia J

    2016-08-01

    PF-05231023, a long-acting FGF21 analogue, is a promising potential pharmacotherapy for the treatment of obesity and associated comorbidities. Previous studies have shown the potential of FGF21 and FGF21-like compounds to decrease body weight in mice, non-human primates, and humans; the precise mechanisms of action remain unclear. In particular, there have been conflicting reports on the degree to which FGF21-induced weight loss in non-human primates is attributable to a decrease in food intake versus an increase in energy expenditure. Here, we present a semi-mechanistic mathematical model of energy balance and body composition developed from similar work in mice. This model links PF-05231023 administration and washout to changes in food intake, which in turn drives changes in body weight. The model is calibrated to and compared with recently published data from cynomolgus macaques treated with PF-05231023, demonstrating its accuracy in describing pharmacotherapy-induced weight loss in these animals. The results are consistent with the hypothesis that PF-05231023 decreases body weight in cynomolgus macaques solely by a reduction in food intake, with no direct effect on energy expenditure.

  1. Lower pole stones: prone PCNL versus supine PCNL in the International Cooperation in Endourology (ICE) group experience.

    Science.gov (United States)

    Sanguedolce, Francesco; Breda, Alberto; Millan, Felix; Brehmer, Marianne; Knoll, Thomas; Liatsikos, Evangelos; Osther, Palle; Traxer, Olivier; Scoffone, Cesare

    2013-12-01

    To assess efficacy and safety of prone- and supine percutaneous nephrolithotomy (PCNL) for the treatment of lower pole kidney stones. Data from patients affected by lower pole kidney stones and treated with PCNL between December 2005 and August 2010 were collected retrospectively by seven referral centres. Variables analysed included patient demographics, clinical and surgical characteristics, stone-free rates (SFR) and complications. Statistical analysis was conducted to compare the differences for SFRs and complication rates between prone- and supine PCNL. One hundred seventeen patients underwent PCNL (mean stone size: 19.5 mm) for stones harboured only in the lower renal pole (single stone: 53.6%; multiple stones: 46.4%). A higher proportion of patients with ASA score ≥ 3 and harbouring multiple lower pole stones were treated with supine PCNL (5.8 vs. 23.1%; p = 0.0001, and 25 vs. 81.5%; p = 0.0001, respectively, for prone- and supine PCNL). One-month SFR was 88.9%; an auxiliary procedure was needed in 6 patients; the 3-month SFR was 90.2%. There were 9 post-operative major complications (7.7%). No differences were observed in terms of 1- and 3-month SFRs (90.4 vs. 87.7%; p = 0.64; 92.3 vs. 89.2%; p = 0.4) and complication rates (7.6 vs. 7.7%; p = 0.83) when comparing prone- versus supine PCNL, respectively. The results confirm the high success rate and relatively low morbidity of modern PCNL for lower pole stones, regardless the position used. Supine PCNL was more frequently offered in case of patients at higher ASA score and in case of multiple lower pole stones.

  2. Anesthetic Efficacy of Supine and Upright Positions for the Inferior Alveolar Nerve Block: A Prospective, Randomized Study.

    Science.gov (United States)

    Crowley, Chase; Drum, Melissa; Reader, Al; Nusstein, John; Fowler, Sara; Beck, Mike

    2018-02-01

    It has been recommended to place patients in an upright position after administration of an inferior alveolar nerve block (IANB), theoretically allowing the anesthetic to diffuse in an inferior direction and resulting in better pulpal anesthesia. The purpose of this study was to compare an upright versus a supine position on the success of pulpal anesthesia when an IANB was administered in asymptomatic teeth. One hundred ten asymptomatic subjects were randomly given IANBs by using 2% lidocaine with 1:100,000 epinephrine while they were in an upright position and supine position at 2 different appointments spaced at least 2 weeks apart. Pulpal anesthesia was measured in the molars, premolars, and incisors with an electric pulp tester in 4-minute cycles for 60 minutes. Anesthetic success was defined as the subject achieving 2 consecutive 80 readings within 15 minutes of the injection and sustaining the 80 reading for 60 minutes. Success was analyzed by using a mixed model logistic regression. Pulpal anesthesia for the supine position was not statistically more successful than the upright position in the second molars (73% vs 65%), first molars (59% vs 54%), lateral incisors (28% vs 23%), and central incisors (11% vs 8%), respectively. The supine position significantly improved success in the second premolars (63% vs 53%) and first premolars (75% vs 64%). The supine and upright positions were equally successful in the molars and anterior teeth. The supine position was more successful in the premolars. However, clinically, neither position for the IANB administration would provide complete pulpal anesthesia. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Semi-automatic detection and correction of body organ motion, particularly cardiac motion in SPECT studies

    International Nuclear Information System (INIS)

    Quintana, J.C.; Caceres, F.; Vargas, P.

    2002-01-01

    patient and artificially imposed). The method is fast (<20s) and robust as compared with manual or other semi-automatic detection of body organ motions in nuclear medicine studies. Conclusion: A fast and robust semi-automatic patient motion detection and correction for SPECT studies has been developed

  4. A randomised trial of Supine versus Prone breast radiotherapy (SuPr study): Comparing set-up errors and respiratory motion

    International Nuclear Information System (INIS)

    Kirby, Anna M.; Evans, Philip M.; Helyer, Sarah J.; Donovan, Ellen M.; Convery, Helen M.; Yarnold, John R.

    2011-01-01

    Purpose: To test a prone position against the international-standard supine position in women undergoing whole-breast-radiotherapy (WBRT) after wide-local-excision (WLE) of early breast cancer (BC) in terms of feasibility, set-up errors, and respiratory motion. Methods: Following WLE of BC with insertion of tumour-bed clips, patients underwent 4D-CT for WBRT-planning in supine and prone positions (the latter using an in-house-designed platform). Patients were randomised to undergo WBRT fractions 1-7 in one position, switching to the alternate position for fractions 8-15 (40 Gy/15-fractions total). Cone-beam CT-images (CBCT) were acquired prior to fractions 1, 4, 7, 8, 11 and 14. CBCT data were matched to planning-CT data using (i) chest-wall and (ii) clips. Systematic and random errors were calculated. Maximal displacement of chest-wall and clips with respiration was measured on 4D-CT. Clinical- to planning-target-volume (CTV-PTV) margins were calculated. Patient-comfort-scores and treatment-times were evaluated. Results: Twenty-five patients were randomized. 192/192 (100%) planned supine fractions and 173/192 (90%) prone fractions were completed. 3D population systematic errors were 1.3-1.9 mm (supine) and 3.1-4.3 mm (prone) (p = 0.02) and random errors 2.6-3.2 mm (supine) and 3.8-5.4 mm (prone) (p = 0.02). Prone positioning reduced chest-wall and clip motion (0.5 ± 0.2 mm (prone) versus 2.7 ± 0.5 mm (supine) (p < 0.001)) with respiration. Calculated CTV-PTV margins were greater for prone (12-16 mm) than for supine treatment (10 mm). Patient-comfort-scores and treatment times were comparable (p = 0.06). Conclusions: Set-up errors were greater using our prone technique than for our standard supine technique, resulting in the need for larger CTV-PTV margins in the prone position. Further work is required to optimize the prone treatment-platform and technique before it can become a standard treatment option at our institution.

  5. Human body region enhancement method based on Kinect infrared imaging

    Science.gov (United States)

    Yang, Lei; Fan, Yubo; Song, Xiaowei; Cai, Wenjing

    2016-10-01

    To effectively improve the low contrast of human body region in the infrared images, a combing method of several enhancement methods is utilized to enhance the human body region. Firstly, for the infrared images acquired by Kinect, in order to improve the overall contrast of the infrared images, an Optimal Contrast-Tone Mapping (OCTM) method with multi-iterations is applied to balance the contrast of low-luminosity infrared images. Secondly, to enhance the human body region better, a Level Set algorithm is employed to improve the contour edges of human body region. Finally, to further improve the human body region in infrared images, Laplacian Pyramid decomposition is adopted to enhance the contour-improved human body region. Meanwhile, the background area without human body region is processed by bilateral filtering to improve the overall effect. With theoretical analysis and experimental verification, the results show that the proposed method could effectively enhance the human body region of such infrared images.

  6. Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

    International Nuclear Information System (INIS)

    Williams, Jason M.; Rani, Sudheer D.; Li, Xia; Whisenant, Jennifer G.; Abramson, Richard G.; Arlinghaus, Lori R.; Lee, Tzu-Cheng; MacDonald, Lawrence R.; Partridge, Savannah C.; Kang, Hakmook; Linden, Hannah M.; Kinahan, Paul E.; Yankeelov, Thomas E.

    2015-01-01

    Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [ 18 F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV peak and SUV max , respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV peak and SUV max from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV peak and SUV max were significantly lower than supine in both

  7. Influência do nível de habilidade e posição corporal no alcance de lactentes Influence of skill level and body position on infants’ reaching

    Directory of Open Access Journals (Sweden)

    RP Carvalho

    2008-06-01

    Full Text Available CONTEXTUALIZAÇÃO: Embora o desenvolvimento do alcance em diferentes posições corporais tem sido amplamente estudado, há poucas pesquisas sobre este assunto, considerando o nível de habilidade do lactente. Objetivo: Verificar como as posições corporais afetam os ajustes proximais e distais do alcance manual de lactentes de quatro a seis meses. MATERIAIS E MÉTODOS: Dez lactentes classificados como menos (n=6 e mais habilidosos (n=4 foram avaliados no mês de aquisição do alcance (M1 e após um mês de prática espontânea (M2, nas posições supina (0º, reclinada (45º e sentada (70º. Foram analisados os ajustes proximais (alcances uni ou bimanuais e distais (mão aberta, semi-aberta ou fechada, posição das mãos no início do movimento (perto ou longe do corpo e movimentos de preensão. RESULTADOS: Houve predomínio de alcances unimanuais para os lactentes mais habilidosos. Os lactentes menos habilidosos apresentaram maior freqüência de alcances unimanuais em M1 (sentado e M2 (supino e sentado. Houve predomínio de alcances com as mãos semi-abertas, exceto para lactentes mais habilidosos em M2 na posição reclinada. Lactentes menos habilidosos apresentaram mãos próximas ao corpo em M1 (reclinado e sentado e M2 (reclinado, enquanto os mais habilidosos iniciaram seus alcances com as mãos longe do corpo em M2 (supino. Lactentes mais habilidosos fizeram mais alcances seguidos de preensão em M2 nas posições supina e sentada. CONCLUSÕES: A posição corporal afeta os ajustes proximais e distais do alcance, de acordo com o nível de habilidade do lactente.BACKGROUND: Although the development of reaching under different body position conditions has been widely studied, little research has addressed this issue considering the infant’s skill level. OBJECTIVE: To investigate how different body positions affect proximal and distal reaching adjustments among four to six-month-old infants. Methods: Ten infants classified as less (n

  8. Human Body Image Edge Detection Based on Wavelet Transform

    Institute of Scientific and Technical Information of China (English)

    李勇; 付小莉

    2003-01-01

    Human dresses are different in thousands way.Human body image signals have big noise, a poor light and shade contrast and a narrow range of gray gradation distribution. The application of a traditional grads method or gray method to detect human body image edges can't obtain satisfactory results because of false detections and missed detections. According to tte peculiarity of human body image, dyadic wavelet transform of cubic spline is successfully applied to detect the face and profile edges of human body image and Mallat algorithm is used in the wavelet decomposition in this paper.

  9. Reproductive performance and body weight changes in draught cows in a smallholder semi-arid farming area of Zimbabwe.

    Science.gov (United States)

    Chimonyo, M; Kusina, N T; Hamudikuwanda, H; Nyoni, O

    2000-12-01

    The reproductive performance of 46 cows in a semi-arid, smallholder farming area of Zimbabwe was monitored for a year. Half the cows were used throughout the monitoring period for various draught purposes, including ploughing and procurement of farm produce for marketing using carts. All the cows lost body weight between July and October, after which the cows that were not worked gained weight until June of the following year. In contrast, the cows that were worked continued to lose body weight until January, throughout the time during which they were used to provide draught power, after which they gained weight. Body weights were significantly higher (p draught purposes caused loss of body weight and reduced ovarian activity and conception rates.

  10. TU-H-CAMPUS-TeP1-02: Seated Treatment: Setup Uncertainty Comparable to Supine

    Energy Technology Data Exchange (ETDEWEB)

    McCarroll, R [UT MD Anderson Cancer Center, Houston, TX (United States); UT Health Science Center, Graduate School of Biomedical Sciences, Houston, TX (United States); Beadle, B; Fullen, D; Balter, P; Followill, D; Stingo, F; Yang, J; Court, L [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: For some head and neck patients, positioning in the supine position is not well tolerated. For these patients, treatment in a seated position would be preferred. We have evaluated inter- and intra- fraction uncertainty of patient set-up in a novel treatment chair which is compatible with modern linac designs. Methods: Five head-and-neck cancer patients were positioned in the chair, fitted with immobilization devices, and imaged with orthogonal X-rays. The couch (with chair attached) was rotated to simulate delivery (without actual treatment), another set of images were acquired, providing a measure of intra-fraction displacement. The patient then got off of and back onto the chair and the process was repeated, thus providing a measure of inter-fraction set-up uncertainty. Six sub-regions in the head-and-neck were rigidly registered to evaluate local intra- and interfraction displacement. Image guidance was simulated by first registering one sub-region; the residual displacement of other sub-regions was then measured. Additionally, a patient questionnaire was administered to evaluate tolerance of the seated position. Results: The chair design is such that all advantages of couch motions may be utilized. Average inter- and intrafraction displacements of all sub-regions in the seated position were less than 2 and 3 mm, respectively. When image guidance was simulated, interfraction displacements were reduced by an average of 4 mm, providing comparable setup to the supine position. The enrolled patients, who had no indication for a seated treatment position, reported no preference for the seated or the supine position. Conclusion: The novel chair design provides acceptable inter- and intra-fraction displacement, with reproducibility similar to that observed for patients in the supine position. Such a chair will be utilized for patients who cannot tolerate the supine position and use with CBCT images for planning, in a fixed-beam linac system, and for other

  11. [Surgical treatment of pronation and supination external rotation trimalleolar fractures].

    Science.gov (United States)

    Xu, Ye-qing; Zhan, Bei-lei; He, Fei-xiong; Wei, Hong-da

    2008-04-01

    To explore the operative method and its clinical effects of pronation and supination external rotation trimalleolar fractures. From March 2000 to July 2006,42 patients of the pronation and supination external rotation trimalleolar fractures treated with open reduction and internal fixation. Thirty-one were males and 11 were females,with an average age of 40.5 years (from 19 to 76 years). Four cases were open fractures and 38 cases close fractures. The fractures were classified as pronation-external rotation (grade IV) injury in 18 cases and supination-external rotation (grade IV)in 24 cases according to the system of Lauge-Hansen. The time of injury to operation was 2 hours to 27 days. The medial, lateral and posterior malleolus were exposed by standard anteromedial and Gatellier-Chastang approaches. The reduction and internal fixation started with the posterior,then the medial and the lateral malleolus and distal tibiofibular syndesmosis in sequence. The anteroposterior, lateral and mostise X-ray films were taken after operation. All the patients were followed up for an average time of 13.5 months(from 6 to 24 months). The time of union was from 12 to 16 weeks. The results were excellent in 20,good in 16, fair in 4 and poor in 2 cases according to Baird-Jackson ankle scoring system based on pain, stability, walking ability,range of motion and radiological manifestations. The excellent and good rate was 85.7%. There were no infection,malunion and nonunion of the fractures except that the inserted screw to distal tibiofibular syndesmosis was broken in 1 case. The key of operative treatment is to restore the anatomy of ankle and to regain the ankle function maximally.

  12. Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions

    Energy Technology Data Exchange (ETDEWEB)

    Pogson, Elise M. [Centre for Medical Radiation Physics, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong (Australia); Liverpool and Macarthur Cancer Therapy Centres, Liverpool (Australia); Ingham Institute for Applied Medical Research, Liverpool (Australia); Delaney, Geoff P. [Liverpool and Macarthur Cancer Therapy Centres, Liverpool (Australia); Ingham Institute for Applied Medical Research, Liverpool (Australia); South Western Sydney Clinical School, University of New South Wales, Sydney (Australia); School of Medicine, University of Western Sydney, Sydney (Australia); Ahern, Verity [Crown Princess Mary Cancer Care Centre, Westmead Hospital, Westmead (Australia); Boxer, Miriam M. [Liverpool and Macarthur Cancer Therapy Centres, Liverpool (Australia); South Western Sydney Clinical School, University of New South Wales, Sydney (Australia); Chan, Christine [Department of Radiology, Liverpool Hospital, Liverpool (Australia); David, Steven [Peter MacCallum Cancer Centre, Melbourne (Australia); Dimigen, Marion [Department of Radiology, Liverpool Hospital, Liverpool (Australia); Harvey, Jennifer A. [School of Medicine, University of Queensland, Herston (Australia); Princess Alexandra Hospital, Woolloongabba (Australia); Koh, Eng-Siew [Liverpool and Macarthur Cancer Therapy Centres, Liverpool (Australia); Ingham Institute for Applied Medical Research, Liverpool (Australia); South Western Sydney Clinical School, University of New South Wales, Sydney (Australia); Lim, Karen [Liverpool and Macarthur Cancer Therapy Centres, Liverpool (Australia); South Western Sydney Clinical School, University of New South Wales, Sydney (Australia); Papadatos, George [Liverpool and Macarthur Cancer Therapy Centres, Liverpool (Australia); and others

    2016-11-15

    Purpose: To determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. Methods and Materials: Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. Results: Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57 (95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52 (95% CI 0.48-0.56) for MRI supine, 0.56 (95% CI 0.53-0.59) for CT prone and 0.55 (95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41 (95% CI 0.36-0.46) for supine and 0.38 (0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. Conclusions: Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images.

  13. [Case of awake intubation in semi-sitting position for a patient with myasthenia gravis combined with cervical disc hernia utilizing Pentax-AWS Airwayscope].

    Science.gov (United States)

    Komasawa, Nobuyasu; Ueki, Ryusuke; Tomita, Yukihiko; Kaminoh, Yoshiroh; Tashiro, Chikara

    2011-01-01

    We report a case of awake intubation utilizing Pentax-AWS Airwayscope in semi-sitting position. A 74-year-old man with myasthenia gravis and cervical disc hernia was scheduled for distal gastrectomy under general anesthesia. He could not move his head due to severe cervical disc hernia and also could not sufficiently breathe due to the fatigue of respiratory muscles by myasthenia gravis in supine position. With fentanyl bolus administration and lidocaine spray for laryngotracheal anesthesia, we performed awake intubation in semi-sitting position with AWS from cranial side. The patient did not buck during intubation and no hemodynamic change was observed.

  14. Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Jason M.; Rani, Sudheer D.; Li, Xia; Whisenant, Jennifer G.; Abramson, Richard G. [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 and Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee 37232 (United States); Arlinghaus, Lori R. [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 (United States); Lee, Tzu-Cheng [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); MacDonald, Lawrence R.; Partridge, Savannah C. [Department of Radiology, University of Washington, Seattle, Washington 98195 (United States); Kang, Hakmook [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 and Department of Biostatistics, Vanderbilt University, Nashville, Tennessee 37232 (United States); Linden, Hannah M. [Department of Medical Oncology, University of Washington, Seattle, Washington 98195 (United States); Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, Washington 98195 (United States); Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Physics, University of Washington, Seattle, Washington 98195 (United States); Department of Electrical Engineering, University of Washington, Seattle, Washington 98195 (United States); Yankeelov, Thomas E., E-mail: thomas.yankeelov@vanderbilt.edu [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Physics, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Cancer Biology, Vanderbilt University, Nashville, Tennessee 37232 (United States)

    2015-07-15

    Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were

  15. Dorian Supin käis Pärdi asjus Argentinas / T.T.

    Index Scriptorium Estoniae

    T.T.

    2003-01-01

    Dokumentaalfilm helilooja Arvo Pärdist "24 prelüüdi ühele fuugale". Filmi stsenarist, režissöör ja operaator Dorian Supin näitas seda suure menuga Buenos Airese San Martini ülikoolis spetsiaalse seminari osavõtjatele

  16. Multichannel Human Body Communication

    International Nuclear Information System (INIS)

    Przystup, Piotr; Bujnowski, Adam; Wtorek, Jerzy

    2016-01-01

    Human Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog signal has been tested. Experiment results show that HBC is a feasible solution for transmitting data between BSN nodes

  17. Human Identification at a Distance Using Body Shape Information

    International Nuclear Information System (INIS)

    Rashid, N K A M; Yahya, M F; Shafie, A A

    2013-01-01

    Shape of human body is unique from one person to another. This paper presents an intelligent system approach for human identification at a distance using human body shape information. The body features used are the head, shoulder, and trunk. Image processing techniques for detection of these body features were developed in this work. Then, the features are recognized using fuzzy logic approach and used as inputs to a recognition system based on a multilayer neural network. The developed system is only applicable for recognizing a person from its frontal view and specifically constrained to male gender to simplify the algorithm. In this research, the accuracy for human identification using the proposed method is 77.5%. Thus, it is proved that human can be identified at a distance using body shape information

  18. Prone versus supine thallium myocardial SPECT: A method to decrease artifactual inferior wall defects

    International Nuclear Information System (INIS)

    Segall, G.M.; Davis, M.J.

    1989-01-01

    Artifactual inferior wall defects as a result of diaphragmatic attenuation of activity are a frequent source of error in thallium myocardial single photon emission computed tomography (SPECT) studies. Thirty-four patients and 11 clinically normal volunteers were studied prospectively to see if specificity of inferior wall defects for right coronary artery disease could be improved by scanning patients prone versus supine. All individuals were scanned both prone and supine, in random order, following symptom limited treadmill exercise. Images were acquired at 3 degrees steps, 25 sec per frame, in a 180 degrees elliptical orbit always beginning in the 45 degrees right anterior oblique position relative to the patient. Polar maps generated from the short axis slices were used to calculate the average regional activity. The prone studies showed consistently higher inferior wall activity compared to the supine studies on both the exercise (182 +/- 22 vs. 160 +/- 23, p less than or equal to 0.001) and 4-hr delay studies (183 +/- 20 vs. 175 +/- 21, p less than or equal to 0.001). Prone imaging resulted in a significantly higher specificity for RCA disease compared to supine imaging (90% vs. 66%, p less than 0.05) with an improvement in accuracy from 71% to 82%. Sensitivity, specificity, and accuracy for left anterior descending and left circumflex artery disease were not significantly affected by patient position during imaging. All patients having SPECT thallium myocardial perfusion studies should be imaged prone to minimize artifactual inferior wall defects and improve accuracy

  19. [Outcome of operative treatment for supination-external rotation Lauge-Hansen stage IV ankle fractures].

    Science.gov (United States)

    Kołodziej, Łukasz; Boczar, Tomasz; Bohatyrewicz, Andrzej; Zietek, Paweł

    2010-01-01

    Ankle fractures are among the most common musculoskeletal injures. These fractures occur with an overall age- and sex-adjusted incidence rate around 180 per 100 000 person-years. The most frequent mechanism is considered to be supination-external rotation (60 to 80% of all ankle fractures) consisting of pathologic external rotation of the foot initially placed in some degree of supination. According to Lauge-Hansen classification, ankle joint structures are damaged in a sequence where the final, stage IV injuries, represents transverse fracture of the medial malleolus or its equivalent-rupture of the deltoid ligament. The aim of this study is to compare the results of two subtypes of supination-external rotation stage IV fractures. 43 patients treated surgically in 2006 to 2007 at Authors institution because of stage IV supination-external rotation ankle fracture were submitted to retrospective analysis. There were 25 patients with bimalleolar fracture (type 1) and in 18 patients with lateral malleolar fracture with accompanying rupture of the deltoid ligament (type 2). The mean age was 46 years (from 20 to 82 years). Average follow up period was 37 months (from 24 to 46 months). For the evaluation of treatment AOFAS hind-foot score (American Orthopedic Foot and Ankle Society) was used. The mean AOFAS score scale for Type 1 fractures was 85 points and for type 2 was significantly higher and amounted to 91 points (p ankle fractures with medial malleolar fracture, requires the implementation of additional diagnostic and therapeutic strategies and procedures in order to improve the outcome of results.

  20. Noninvasive, three-dimensional full-field body sensor for surface deformation monitoring of human body in vivo

    Science.gov (United States)

    Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin

    2017-09-01

    Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery.

  1. Comparison of CT myelography performed in the prone and supine positions in the detection of cervical spinal stenosis

    International Nuclear Information System (INIS)

    Blease Graham, Cole III; Wippold, Franz J. II; Bae, Kyongtae T.; Pilgram, Thomas K.; Shaibani, Ali; Kido, Daniel K.

    2001-01-01

    AIM: To quantify the change in the cross-sectional area of the cervical spinal cord and subarachnoid space (SAS) in the supine neutral vs prone extension positions in patients with myelopathy undergoing cervical CT myelography. MATERIAL AND METHODS: Axial CT myelgrams of 21 myelopathic patients were performed in both the supine neutral and prone extension positions. The SAS and cord cross-sectional areas were then measured at the disk spaces and mid-pedicle levels from C2 to T1 in both the supine and prone positions using a public domain NIH Image program, version 156b18. Mean area measurements in both positions were then compared for each level examined. RESULTS: Mean SAS cross-sectional area in the prone position was notably reduced compared with the supine position at C4-C5 [128.8 mm 2 vs 168.1 mm 2 (P 2 vs 143.2 mm 2 (P< .05)] disk levels. The mean cord cross-sectional area failed to change signficantly with positioning. CONCLUSIONS: Prone myelography may demonstrate a greater degree of cervical spine stenosis compared with CT myelography performed in the supine position in myelopathic patients. Imaging with the patient prone with neck extended in both myelography and CTM may improve precision in the results of measurements of the stenotic spinal canal when comparing these two methods. Blease Graham III, C. (2001)

  2. A normal mode treatment of semi-diurnal body tides on an aspherical, rotating and anelastic Earth

    Science.gov (United States)

    Lau, Harriet C. P.; Yang, Hsin-Ying; Tromp, Jeroen; Mitrovica, Jerry X.; Latychev, Konstantin; Al-Attar, David

    2015-08-01

    Normal mode treatments of the Earth's body tide response were developed in the 1980s to account for the effects of Earth rotation, ellipticity, anelasticity and resonant excitation within the diurnal band. Recent space-geodetic measurements of the Earth's crustal displacement in response to luni-solar tidal forcings have revealed geographical variations that are indicative of aspherical deep mantle structure, thus providing a novel data set for constraining deep mantle elastic and density structure. In light of this, we make use of advances in seismic free oscillation literature to develop a new, generalized normal mode theory for the tidal response within the semi-diurnal and long-period tidal band. Our theory involves a perturbation method that permits an efficient calculation of the impact of aspherical structure on the tidal response. In addition, we introduce a normal mode treatment of anelasticity that is distinct from both earlier work in body tides and the approach adopted in free oscillation seismology. We present several simple numerical applications of the new theory. First, we compute the tidal response of a spherically symmetric, non-rotating, elastic and isotropic Earth model and demonstrate that our predictions match those based on standard Love number theory. Second, we compute perturbations to this response associated with mantle anelasticity and demonstrate that the usual set of seismic modes adopted for this purpose must be augmented by a family of relaxation modes to accurately capture the full effect of anelasticity on the body tide response. Finally, we explore aspherical effects including rotation and we benchmark results from several illustrative case studies of aspherical Earth structure against independent finite-volume numerical calculations of the semi-diurnal body tide response. These tests confirm the accuracy of the normal mode methodology to at least the level of numerical error in the finite-volume predictions. They also demonstrate

  3. Physiological Response to Static Muscle Contractions in Standing and Supine Positions

    DEFF Research Database (Denmark)

    Pedersen, Jens Meldgaard; Andersen, T. Bull

    2013-01-01

    The purpose of this study was to investigate the physiological responses to static muscle contractions in the standing position and the supine position. Eight subjects performed static contractions of the ankle extensors in both positions. Blood pressure (SBP and DBP), heart rate (HR...

  4. SU-F-T-536: Contra-Lateral Breast Study for Prone Versus Supine Patients

    Energy Technology Data Exchange (ETDEWEB)

    Marrero, M; Joseph, K; Klein, E [Northwell Health, Lake Success, NY (United States)

    2016-06-15

    Purpose: There are several advantages to utilizing the prone technique for intact breast cancer patients. However, as the topography changes, accompanied by the influence of a supporting breast board and patient treatment couch, the question that arises is to whether there is a concern for contralateral breast dose for intact breast cancer patients being treated with this technique. Methods: An anthropomorphic phantom with breast mounds to duplicate intact breast cancer treatment was planned in prone and supine position. Two tangential beams were executed in the similar manner for as the radiotherapy planning system. For the prone setup, a breast dense foam board was used to support the phantom. A grid of 24 OSL nanodots was placed at 6cm, 4cm, and 2cm apart from the medial border for both prone and supine setups. The phantom was set up using megavoltage imaging and treated as per plan. Additional, a similar study was performed on a patient treated in prone position. Results: Overall, the contralateral breast dose was generally higher for prone setups at all locations especially when close to the medial border. The average mean dose was found to be 1.8%, 2.5% of the prescribed dose for supine respectively prone position. The average of the standard deviation is 1.04%, 1.38% for supine respectively prone position. As for patient treated in prone position average mean dose was found to be 1.165% of the prescribed dose and average of the standard deviation is 9.456%. Conclusion: There is minimal influence of scatter from the breast board. It appears that the volatility of the setup could lead to higher doses than expected from the planning system to the contralateral breast when the patient is in the prone position.

  5. Microwave non-contact imaging of subcutaneous human body tissues.

    Science.gov (United States)

    Kletsov, Andrey; Chernokalov, Alexander; Khripkov, Alexander; Cho, Jaegeol; Druchinin, Sergey

    2015-10-01

    A small-size microwave sensor is developed for non-contact imaging of a human body structure in 2D, enabling fitness and health monitoring using mobile devices. A method for human body tissue structure imaging is developed and experimentally validated. Subcutaneous fat tissue reconstruction depth of up to 70 mm and maximum fat thickness measurement error below 2 mm are demonstrated by measurements with a human body phantom and human subjects. Electrically small antennas are developed for integration of the microwave sensor into a mobile device. Usability of the developed microwave sensor for fitness applications, healthcare, and body weight management is demonstrated.

  6. Stretch sensors for human body motion

    Science.gov (United States)

    O'Brien, Ben; Gisby, Todd; Anderson, Iain A.

    2014-03-01

    Sensing motion of the human body is a difficult task. From an engineers' perspective people are soft highly mobile objects that move in and out of complex environments. As well as the technical challenge of sensing, concepts such as comfort, social intrusion, usability, and aesthetics are paramount in determining whether someone will adopt a sensing solution or not. At the same time the demands for human body motion sensing are growing fast. Athletes want feedback on posture and technique, consumers need new ways to interact with augmented reality devices, and healthcare providers wish to track recovery of a patient. Dielectric elastomer stretch sensors are ideal for bridging this gap. They are soft, flexible, and precise. They are low power, lightweight, and can be easily mounted on the body or embedded into clothing. From a commercialisation point of view stretch sensing is easier than actuation or generation - such sensors can be low voltage and integrated with conventional microelectronics. This paper takes a birds-eye view of the use of these sensors to measure human body motion. A holistic description of sensor operation and guidelines for sensor design will be presented to help technologists and developers in the space.

  7. Body Position Influences Which Neural Structures Are Recruited by Lumbar Transcutaneous Spinal Cord Stimulation.

    Directory of Open Access Journals (Sweden)

    Simon M Danner

    Full Text Available Transcutaneous stimulation of the human lumbosacral spinal cord is used to evoke spinal reflexes and to neuromodulate altered sensorimotor function following spinal cord injury. Both applications require the reliable stimulation of afferent posterior root fibers. Yet under certain circumstances, efferent anterior root fibers can be co-activated. We hypothesized that body position influences the preferential stimulation of sensory or motor fibers. Stimulus-triggered responses to transcutaneous spinal cord stimulation were recorded using surface-electromyography from quadriceps, hamstrings, tibialis anterior, and triceps surae muscles in 10 individuals with intact nervous systems in the supine, standing and prone positions. Single and paired (30-ms inter-stimulus intervals biphasic stimulation pulses were applied through surface electrodes placed on the skin between the T11 and T12 inter-spinous processes referenced to electrodes on the abdomen. The paired stimulation was applied to evaluate the origin of the evoked electromyographic response; trans-synaptic responses would be suppressed whereas direct efferent responses would almost retain their amplitude. We found that responses to the second stimulus were decreased to 14%±5% of the amplitude of the response to the initial pulse in the supine position across muscles, to 30%±5% in the standing, and to only 80%±5% in the prone position. Response thresholds were lowest during standing and highest in the prone position and response amplitudes were largest in the supine and smallest in the prone position. The responses obtained in the supine and standing positions likely resulted from selective stimulation of sensory fibers while concomitant motor-fiber stimulation occurred in the prone position. We assume that changes of root-fiber paths within the generated electric field when in the prone position increase the stimulation thresholds of posterior above those of anterior root fibers. Thus, we

  8. [Body modifications and sexual health : Impact of tattoos, body piercing and esthetic genital plastic surgery on the sexual health of women and men].

    Science.gov (United States)

    Stirn, Aglaja Valentina; Zannoni, Ronja

    2017-09-01

    The present paper addresses the psychological impact of body modifications (e.g. tattoos, body piercing and esthetic genital plastic surgery) on the sexual health of individuals and refers to past and present research insights. Body modifications are understood as invasive interventions on the human body, especially interventions on the human skin which result in (semi-)permanent changes. Tattoos and body piercing (in particular genital piercing) positively affect the sexual satisfaction and the sexual appeal of men and women but there is a controversial association with high risk sexual behavior. Moreover, this article focuses on esthetic genital plastic surgery based on the increasing interest and insights of the impact on female genital self-perception and sexual behavior.

  9. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans

    Directory of Open Access Journals (Sweden)

    Alizé Lacoste Jeanson

    2017-05-01

    Full Text Available Background Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. Methods We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT and lean tissue (LT in such material. An intra-class correlation coefficient (ICC was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS linear regressions and support vector machine regression (SVMR. Results and Discussion The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5 and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77 than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08 for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  10. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans.

    Science.gov (United States)

    Lacoste Jeanson, Alizé; Dupej, Ján; Villa, Chiara; Brůžek, Jaroslav

    2017-01-01

    Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT) and lean tissue (LT) in such material. An intra-class correlation coefficient (ICC) was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS) linear regressions and support vector machine regression (SVMR). The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5) and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77) than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08) for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  11. Post-human body and beauty.

    Science.gov (United States)

    Russo, Maria Teresa; Di Stefano, Nicola

    2014-01-01

    The article calls into question the very possibility of a post-human aesthetics, starting from the following premise: rather than post-human, it is more correct to speak of post-natural, indicating by this expression a reality produced through a new type of evolution, which does not simply change human nature, but de-natures it, radically transforming it into an artefact. This post-nature which aspires to be perfect, immortal, invulnerable, is entirely devoid of beauty. In fact, while there may be an aesthetic of the artificial and of the artefact if it is in relation to objects, there is, however, no aesthetic of the post-human body. This is because is configured as a non-body and does not have the characteristics for what is commonly intended as beauty (harmony between matter and form, a reflection of inner life, uniqueness). Also in this case, it is more correct to speak of post-beauty, which in its properties appears to be the mirror image of beauty and ultimately, represents its complete dissolution.

  12. Noninvasive, three-dimensional full-field body sensor for surface deformation monitoring of human body in vivo.

    Science.gov (United States)

    Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin

    2017-09-01

    Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  13. New reusable elastomer electrodes for assessing body composition

    International Nuclear Information System (INIS)

    Moreno, M-V; Chaset, L; Bittner, P A; Barthod, C; Passard, M

    2013-01-01

    The development of telemedicine requires finding solutions of reusable electrodes for use in patients' homes. The objective of this study is to evaluate the relevance of reusable elastomer electrodes for measuring body composition. We measured a population of healthy Caucasian (n = 17). A measurement was made with a reference device, the Xitron®, associated with AgCl Gel electrodes (Gel) and another measurement with a multifrequency impedancemeter Z-Metrix® associated with reusable elastomer electrodes (Elast). We obtained a low variability with an average error of repeatability of 0.39% for Re and 0.32% for Rinf. There is a non significantly difference (P T-test > 0.1) about 200 ml between extracellular water Ve measured with Gel and Elast in supine and in standing position. For total body water Vt, we note a non significantly difference (P T-test > 0.1) about 100 ml and 2.2 1 respectively in supine and standing position. The results give low dispersion, with R 2 superior to 0.90, with a 1.5% maximal error between Gel and Elast on Ve in standing position. It looks possible, taking a few precautions, using elastomer electrodes for assessing body composition.

  14. Effect of Sitting Pause Times on Balance After Supine to Standing Transfer in Dim Light.

    Science.gov (United States)

    Johnson, Eric G; Albalwi, Abdulaziz A; Al-Dabbak, Fuad M; Daher, Noha S

    2017-06-01

    The risk of falling for older adults increases in dimly lit environments. Longer sitting pause times, before getting out of bed and standing during the night, may improve postural stability. The purpose of this study was to measure the effect of sitting pause times on postural sway velocity immediately after a supine to standing transfer in a dimly lit room in older adult women. Eighteen healthy women aged 65 to 75 years who were able to independently perform supine to standing transfers participated in the study. On each of 2 consecutive days, participants assumed the supine position on a mat table and closed their eyes for 45 minutes. Then, participants were instructed to open their eyes and transfer from supine to sitting, with either 2- or 30-second pause in the sitting position followed by standing. The sitting pause time order was randomized. A significant difference was observed in postural sway velocity between the 2- and 30-second sitting pause times. The results revealed that there was less postural sway velocity after 30-second than 2-second sitting pause time (0.61 ± 0.19 vs 1.22 ± 0.68, P Falls related to bathroom usage at night are the most common reported falls among older adults. In the present study, the investigators studied the effect of sitting pause times on postural sway velocity after changing position from supine to standing in a dimly lit environment. The findings showed that the mean postural sway velocity was significantly less after 30-second sitting pause time compared with 2-second sitting pause time. Postural sway velocity decreased when participants performed a sitting pause of 30 seconds before standing in a dimly lit environment. These results suggest that longer sitting pause times may improve adaptability to dimly lit environments, contributing to improved postural stability and reduced risk of fall in older adult women when getting out of bed at night.

  15. Alternated Prone and Supine Whole-Breast Irradiation Using IMRT: Setup Precision, Respiratory Movement and Treatment Time

    International Nuclear Information System (INIS)

    Veldeman, Liv; De Gersem, Werner; Speleers, Bruno; Truyens, Bart; Van Greveling, Annick; Van den Broecke, Rudy; De Neve, Wilfried

    2012-01-01

    Purpose: The objective of this study was to compare setup precision, respiration-related breast movement and treatment time between prone and supine positions for whole-breast irradiation. Methods and Materials: Ten patients with early-stage breast carcinoma after breast-conserving surgery were treated with prone and supine whole breast-irradiation in a daily alternating schedule. Setup precision was monitored using cone-beam computed tomography (CBCT) imaging. Respiration-related breast movement in the vertical direction was assessed by magnetic sensors. The time needed for patient setup and for the CBCT procedure, the beam time, and the length of the whole treatment slot were also recorded. Results: Random and systematic errors were not significantly different between positions in individual patients for each of the three axes (left-right, longitudinal, and vertical). Respiration-related movement was smaller in prone position, but about 80% of observations showed amplitudes <1 mm in both positions. Treatment slots were longer in prone position (21.2 ± 2.5 min) than in supine position (19.4 ± 0.8 min; p = 0.044). Conclusion: Comparison of setup precision between prone and supine position in the same patient showed no significant differences in random and systematic errors. Respiratory movement was smaller in prone position. The longer treatment slots in prone position can probably be attributed to the higher repositioning need.

  16. Factors driving semi-aquatic predator occurrence in traditional cattle drinking pools: conservation issues

    Directory of Open Access Journals (Sweden)

    Raoul Manenti

    2016-08-01

    Full Text Available In several cases, human impact on water bodies and on their freshwater communities is detrimental, but in some cases the human activity may favour and enhance the biodiversity of small water bodies, as traditional cattle drinking pools. Despite their small size, small water bodies may constitute hot spot of biodiversity often representing the only lentic aquatic biotope in landscapes where superficial water lacks or flows in lotic environments like creeks and streams. Predators are good indicators of biodiversity in ponds and give information of food chain web complexity. In particular, semi-aquatic predators like amphibians and dragonflies may account for a substantial percentage of energy flow between aquatic and terrestrial ecosystems. In this study, we evaluated the conservation value of traditional cattle drinking pools building by assessing the factors determining the occurrence and distribution of the semi-aquatic predators. From April to August 2015, we investigated 30 distinct pools recording several abiotic and biotic environmental variables. We detected 4 semi-aquatic predators: Salamandra salamandra larvae, Triturus carnifex, Aeshna sp. larvae and Libellula sp. larvae. Abiotic features played a major role in shaping the predator community that resulted linked to stable, with no dryness period, and large drinking pools. Invertebrate prey biomass was not particularly important, while vegetation cover and occurrence of unpalatable tadpoles were the most important biotic features of the pools. Our study provides novel evidence on the importance of cattle drinking pools management to preserve biodiversity especially in areas where traditional pastoral activity is disappearing.

  17. Evaluation of a semi-automated computer algorithm for measuring total fat and visceral fat content in lambs undergoing in vivo whole body computed tomography.

    Science.gov (United States)

    Rosenblatt, Alana J; Scrivani, Peter V; Boisclair, Yves R; Reeves, Anthony P; Ramos-Nieves, Jose M; Xie, Yiting; Erb, Hollis N

    2017-10-01

    Computed tomography (CT) is a suitable tool for measuring body fat, since it is non-destructive and can be used to differentiate metabolically active visceral fat from total body fat. Whole body analysis of body fat is likely to be more accurate than single CT slice estimates of body fat. The aim of this study was to assess the agreement between semi-automated computer analysis of whole body volumetric CT data and conventional proximate (chemical) analysis of body fat in lambs. Data were collected prospectively from 12 lambs that underwent duplicate whole body CT, followed by slaughter and carcass analysis by dissection and chemical analysis. Agreement between methods for quantification of total and visceral fat was assessed by Bland-Altman plot analysis. The repeatability of CT was assessed for these measures using the mean difference of duplicated measures. When compared to chemical analysis, CT systematically underestimated total and visceral fat contents by more than 10% of the mean fat weight. Therefore, carcass analysis and semi-automated CT computer measurements were not interchangeable for quantifying body fat content without the use of a correction factor. CT acquisition was repeatable, with a mean difference of repeated measures being close to zero. Therefore, uncorrected whole body CT might have an application for assessment of relative changes in fat content, especially in growing lambs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. A Circuit Model of Real Time Human Body Hydration.

    Science.gov (United States)

    Asogwa, Clement Ogugua; Teshome, Assefa K; Collins, Stephen F; Lai, Daniel T H

    2016-06-01

    Changes in human body hydration leading to excess fluid losses or overload affects the body fluid's ability to provide the necessary support for healthy living. We propose a time-dependent circuit model of real-time human body hydration, which models the human body tissue as a signal transmission medium. The circuit model predicts the attenuation of a propagating electrical signal. Hydration rates are modeled by a time constant τ, which characterizes the individual specific metabolic function of the body part measured. We define a surrogate human body anthropometric parameter θ by the muscle-fat ratio and comparing it with the body mass index (BMI), we find theoretically, the rate of hydration varying from 1.73 dB/min, for high θ and low τ to 0.05 dB/min for low θ and high τ. We compare these theoretical values with empirical measurements and show that real-time changes in human body hydration can be observed by measuring signal attenuation. We took empirical measurements using a vector network analyzer and obtained different hydration rates for various BMI, ranging from 0.6 dB/min for 22.7 [Formula: see text] down to 0.04 dB/min for 41.2 [Formula: see text]. We conclude that the galvanic coupling circuit model can predict changes in the volume of the body fluid, which are essential in diagnosing and monitoring treatment of body fluid disorder. Individuals with high BMI would have higher time-dependent biological characteristic, lower metabolic rate, and lower rate of hydration.

  19. Polycyclic Aromatic Hydrocarbon (PAH Exposure and DNA Adduct Semi-Quantitation in Archived Human Tissues

    Directory of Open Access Journals (Sweden)

    M. Margaret Pratt

    2011-06-01

    Full Text Available Polycyclic aromatic hydrocarbons (PAHs are combustion products of organic materials, mixtures of which contain multiple known and probable human carcinogens. PAHs occur in indoor and outdoor air, as well as in char-broiled meats and fish. Human exposure to PAHs occurs by inhalation, ingestion and topical absorption, and subsequently formed metabolites are either rendered hydrophilic and excreted, or bioactivated and bound to cellular macromolecules. The formation of PAH-DNA adducts (DNA binding products, considered a necessary step in PAH-initiated carcinogenesis, has been widely studied in experimental models and has been documented in human tissues. This review describes immunohistochemistry (IHC studies, which reveal localization of PAH-DNA adducts in human tissues, and semi-quantify PAH-DNA adduct levels using the Automated Cellular Imaging System (ACIS. These studies have shown that PAH-DNA adducts concentrate in: basal and supra-basal epithelium of the esophagus, cervix and vulva; glandular epithelium of the prostate; and cytotrophoblast cells and syncitiotrophoblast knots of the placenta. The IHC photomicrographs reveal the ubiquitous nature of PAH-DNA adduct formation in human tissues as well as PAH-DNA adduct accumulation in specific, vulnerable, cell types. This semi-quantative method for PAH-DNA adduct measurement could potentially see widespread use in molecular epidemiology studies.

  20. Small-bodied humans from Palau, Micronesia.

    Directory of Open Access Journals (Sweden)

    Lee R Berger

    Full Text Available UNLABELLED: Newly discovered fossil assemblages of small bodied Homo sapiens from Palau, Micronesia possess characters thought to be taxonomically primitive for the genus Homo. BACKGROUND: Recent surface collection and test excavation in limestone caves in the rock islands of Palau, Micronesia, has produced a sizeable sample of human skeletal remains dating roughly between 940-2890 cal ybp. PRINCIPLE FINDINGS: Preliminary analysis indicates that this material is important for two reasons. First, individuals from the older time horizons are small in body size even relative to "pygmoid" populations from Southeast Asia and Indonesia, and thus may represent a marked case of human insular dwarfism. Second, while possessing a number of derived features that align them with Homo sapiens, the human remains from Palau also exhibit several skeletal traits that are considered to be primitive for the genus Homo. SIGNIFICANCE: These features may be previously unrecognized developmental correlates of small body size and, if so, they may have important implications for interpreting the taxonomic affinities of fossil specimens of Homo.

  1. Comparison of the outcomes of complete supine percutaneous nephrolithotomy in patients with radiopaque and radiolucent kidney stones.

    Science.gov (United States)

    Falahatkar, Siavash; Mokhtari, Gholamreza; Amin, Atiyeh; Kazemnezhad, Ehsan; Esmaeili, Samaneh; Herfeh, Nadia Rastjou; Falahatkar, Reza

    2017-12-01

    This study compared the stone opacity effect in patients who had radiopaque and radiolucent stones in percutaneous nephrolithotomy (PCNL) results. The medical records of 171 complete supine PCNL procedures were gathered. Patients were categorized into two groups: those with radiopaque (n=141) and those with radiolucent (n=30) stones. Kidney, ureter and bladder x-ray was done a day after PCNL and Ultrasound imaging was done two weeks later to evaluate the stone free rate. A stone free result was defined as having less than 4 mm residual stone size. Outcome parameters were compared by univariate analysis and those which were significantly different between the two groups were assessed by multivariate binary logistic regression analysis. There were no significant differences in age, sex, body mass index, hypertension, diabetes mellitus, pre-surgery hemoglobin, pre-surgery serum creatinine, stone and also surgery-related parameters between the two groups. Stone free rate, surgery time, complication-related parameters, hemoglobin drop, serum creatinine and glomerular filtration rate (GFR) changes were similar in both groups based on univariate analysis. The radiopaque group had higher post-surgery GFR (p=0.04) and longer hospital stay (p=0.009). However, opacity had no effect on these outcomes after multivariate analysis. Higher post-surgery GFR was seen in patient with higher GFR before surgery (p<0.0001). Also, higher hemoglobin before surgery was correlated with less hospital stay (p=0.001). The complete supine percutaneous nephrolithotomy outcomes are similar in patients with radiopaque and radiolucent stones.

  2. Gamma dose rates to body organs from immersion in a semi-infinite radioactive cloud; an alternate approach using absorbed fraction data for internal radionuclides

    International Nuclear Information System (INIS)

    Gillespie, F.C.

    1982-01-01

    This note shows that reasonable estimates of absorbed γ-dose rates for specific organs arising from whole body immersion in semi-infinite radioactive clouds may be obtained very simply from well known data on absorbed fractions for mono-energetic γ-sources uniformly distributed in the whole body. (author)

  3. A nonintrusive temperature measuring system for estimating deep body temperature in bed.

    Science.gov (United States)

    Sim, S Y; Lee, W K; Baek, H J; Park, K S

    2012-01-01

    Deep body temperature is an important indicator that reflects human being's overall physiological states. Existing deep body temperature monitoring systems are too invasive to apply to awake patients for a long time. Therefore, we proposed a nonintrusive deep body temperature measuring system. To estimate deep body temperature nonintrusively, a dual-heat-flux probe and double-sensor probes were embedded in a neck pillow. When a patient uses the neck pillow to rest, the deep body temperature can be assessed using one of the thermometer probes embedded in the neck pillow. We could estimate deep body temperature in 3 different sleep positions. Also, to reduce the initial response time of dual-heat-flux thermometer which measures body temperature in supine position, we employed the curve-fitting method to one subject. And thereby, we could obtain the deep body temperature in a minute. This result shows the possibility that the system can be used as practical temperature monitoring system with appropriate curve-fitting model. In the next study, we would try to establish a general fitting model that can be applied to all of the subjects. In addition, we are planning to extract meaningful health information such as sleep structure analysis from deep body temperature data which are acquired from this system.

  4. Sandia's severe human body Electrostatic Discharge Tester (SSET)

    International Nuclear Information System (INIS)

    Barnum, J.R.

    1991-01-01

    This paper reports that the Electromagnetic Testing Division at Sandia National Laboratories (SNL) has developed a simulator to replicate a severe human body electrostatic discharge event. This simulator is referred to as Sandia's Severe Human Body Electrostatic Discharge Tester (SSET). The SSET is configured as a coaxial transmission line, which allows control of parasitic inductance and capacitance to achieve the desired waveform signature, and operates reliably at voltages up to 35 kV. It is constructed from off-the-shelf or easily fabricated components and costs approximately $750 for materials, not including the power supply. The output is very repeatable and provides good simulation fidelity of a severe human body discharge

  5. Human body micro-environment: The benefits of controlling airflow interaction

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2015-01-01

    This paper focuses on the micro-environment around a human body, and especially on its interaction with the surrounding environment. Research on the free convection flow generated by a human body (including the convective boundary layer around the body and the thermal plume above the body), its...

  6. Arm rotated medially with supination – the ARMS variant: description of its surgical correction

    Directory of Open Access Journals (Sweden)

    Melcher Sonya E

    2009-03-01

    Full Text Available Abstract Background Patients who have suffered obstetric brachial plexus injury (OBPI have a high incidence of musculoskeletal complications stemming from the initial nerve injury. The presence of muscle imbalances and contractures leads to typical bony changes affecting the shoulder, including the SHEAR (Scapular Hypoplasia, Elevation and Rotation deformity. The SHEAR deformity commonly occurs in conjunction with Medial Rotation Contracture (MRC of the arm. OBPI also causes muscle imbalances at the level of the forearm, that lead to a fixed supination deformity (SD in a small number of patients. Both MRC and SD will cause severe functional limitations without surgical intervention. Methods Fourteen OBPI patients were diagnosed with MRC of the shoulder and SD of the forearm along with SHEAR deformity during a 16 month study period, with eight patients available to long-term follow-up (age range 2.2 – 18 years. Surgical correction of the MRC was performed as a triangle tilt or humeral osteotomy depending on the age of the child, after which, the patients were treated with a radial osteotomy to correct the fixed supination deformity. Function was assessed using the modified Mallet scale, examination of apparent supination and appearance of the extremity at rest. Results Significant functional improvements were observed in patients with surgical reconstruction. Mallet score increased by an average of 5.2 (p Conclusion The simultaneous presence of two opposing deformities in the same limb will visually offset each other at the level of the wrist and hand, giving the false impression of neutral positioning of the limb. In reality, the neutral-appearing position of the hand indicates a fixed supination posture of the forearm in the face of a medial rotation contracture of the shoulder. Both of these deformities require surgical attention, and the presence of concurrent MRC and SD should be monitored for in OBPI patients.

  7. The Reconfigured Body. Human-animal relations in xenotransplantation

    Directory of Open Access Journals (Sweden)

    Kristofer Hansson

    2011-12-01

    Full Text Available The article explores issues concerning the reconfiguration of human and animal bodies in modern biotechnology. The examples are based on xenotransplantation: Transplantation of cells, tissue and organs from animals to humans. Three thematic issues that emerged from xenotransplantation research in Sweden in the 1990s and early 2000s are examined in the article. The first issue concerns how the pig was introduced as a donor animal in xenotransplantation and, at the same time, dehumanized in relation to what is human. Baboons and chimpanzees that had previously been used in xenotransplantation now became an ethically problematic choice, and were in stead humanized. The second issue concerns the introduction of transgenic and cloned pigs as commoditized objects. The biotechnological development reconfigured the pig’s cells, tissue and organs to become more human-like. The third issue concerns the risk that pigs contain retrovirus that could infect the transplanted patients. The human body became part of a network of both animal and retrovirus. Boundlessness between human and animal bodies appears in these three thematic phases and is analysed from a cultural perspective.

  8. [Microbiota and representations of the human body].

    Science.gov (United States)

    Dodet, Betty

    2016-11-01

    Although the presence of an intestinal flora has been known for a long time, the discovery of the role of gut microbiota in human health and disease has been widely recognized as one of the most important advances in the recent years. Chronic diseases may result from dysbiosis, i.e. a disruption of the balance within the bacterial population hosted by the human body. These developments open new prospects in terms of prevention and treatment, including the design of adapted diets, the development of functional foods and fecal transplantation. These discoveries have profoundly altered our view of microbes, of health and disease, of self and non-self, as well as our representations of the body and its relationship with its ecosystem. Gut microbiota is now generally considered as an organ in its own right. A model of the "microbiotic person" thus arises, in which the human organism is defined as an ecosystem, a chimeric superorganism with a double genome, both human and microbial. Thought should be given to the way in which these new paradigms modify lay perceptions of the human body. © 2016 médecine/sciences – Inserm.

  9. Sensitivity of bedside ultrasound and supine anteroposterior chest radiographs for the identification of pneumothorax after blunt trauma.

    Science.gov (United States)

    Wilkerson, R Gentry; Stone, Michael B

    2010-01-01

    Supine anteroposterior (AP) chest radiographs in patients with blunt trauma have poor sensitivity for the identification of pneumothorax. Ultrasound (US) has been proposed as an alternative screening test for pneumothorax in this population. The authors conducted an evidence-based review of the medical literature to compare sensitivity of bedside US and AP chest radiographs in identifying pneumothorax after blunt trauma. MEDLINE and EMBASE databases were searched for trials from 1965 through June 2009 using a search strategy derived from the following PICO formulation of our clinical question: patients included adult (18 + years) emergency department (ED) patients in whom pneumothorax was suspected after blunt trauma. The intervention was thoracic ultrasonography for the detection of pneumothorax. The comparator was the supine AP chest radiograph during the initial evaluation of the patient. The outcome was the diagnostic performance of US in identifying the presence of pneumothorax in the study population. The criterion standard for the presence or absence of pneumothorax was computed tomography (CT) of the chest or a rush of air during thoracostomy tube placement (in unstable patients). Prospective, observational trials of emergency physician (EP)-performed thoracic US were included. Trials in which the exams were performed by radiologists or surgeons, or trials that investigated patients suffering penetrating trauma or with spontaneous or iatrogenic pneumothoraces, were excluded. The methodologic quality of the studies was assessed. Qualitative methods were used to summarize the study results. Data analysis consisted of test performance (sensitivity and specificity, with 95% confidence intervals [CIs]) of thoracic US and supine AP chest radiography. Four prospective observational studies were identified, with a total of 606 subjects who met the inclusion and exclusion criteria. The sensitivity and specificity of US for the detection of pneumothorax ranged from

  10. Differences in abdominal organ movement between supine and prone positions measured using four-dimensional computed tomography

    International Nuclear Information System (INIS)

    Kim, Young Seok; Park, Sung Ho; Ahn, Seung Do; Lee, Jeong Eun; Choi, Eun Kyung; Lee, Sang-wook; Shin, Seong Soo; Yoon, Sang Min; Kim, Jong Hoon

    2007-01-01

    Background and purpose: To analyze the differences in intrafractional organ movement throughout the breathing cycles between the supine and prone positions using four-dimensional computed tomography (4D CT). Materials and methods: We performed 4D CT on nine volunteers in the supine and prone positions, with each examinee asked to breathe normally during scanning. The movement of abdominal organs in the cranio-caudal (CC), anterior-posterior (AP) and right-left (RL) directions was quantified by contouring on each phase between inspiration and expiration. Results: The mean intrafractional motions of the hepatic dome, lower tip, pancreatic head and tail, both kidneys, spleen, and celiac axis in the supine/prone position were 17.3/13.0, 14.4/11.0, 12.8/8.9, 13.0/10.0, 14.3/12.1, 12.3/12.6, 11.7/12.6 and 2.2/1.8 mm, respectively. Intrafractional movements of the liver dome and pancreatic head were reduced significantly in the prone position. The CC directional excursions were major determinants of the 3D displacements of the abdominal organs. Alteration from the supine to the prone position did not change the amount of intrafractional movements of kidneys, spleen, and celiac axis. Conclusion: There was a significant reduction in the movements of the liver and pancreas during the prone position, especially in the CC direction, suggesting possible advantage of radiotherapy to these organs in this position

  11. [The gift of human body's products: philosophical and ethical aspects].

    Science.gov (United States)

    Baertschi, B

    2014-09-01

    In continental Europe, there is a very strong moral condemnation against putting parts or products of the human body on sale-and, consequently, against putting sperms and oocytes on sale. Only a gift is morally permissible. The situation is different in Anglo-Saxon countries. Who is right? Above all, it must be noticed that two views of the human body are facing each other here: for the first, the human body is a part of the person (so, it partakes of the person's dignity), whereas for the second, the human body is a possession of the person (the person is the owner of his/her body). In my opinion, the argument of dignity comes up against serious objections, and the property argument is more consistent. However, it does not follow that it would be judicious to put parts and products of the human body for sale on a market. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. An evaluation of intrafraction motion of the prostate in the prone and supine positions using electromagnetic tracking

    International Nuclear Information System (INIS)

    Shah, Amish P.; Kupelian, Patrick A.; Willoughby, Twyla R.; Langen, Katja M.; Meeks, Sanford L.

    2011-01-01

    Purpose: To evaluate differences in target motion during prostate irradiation in the prone versus supine position using electromagnetic tracking to measure prostate mobility. Materials/methods: Twenty patients received prostate radiotherapy in the supine position utilizing the Calypso Localization System (registered) for prostate positioning and monitoring. For each patient, 10 treatment fractions were followed by a session in which the patient was repositioned prone, and prostate mobility was tracked. The fraction of time that the prostate was displaced by >3, 5, 7, and 10 mm was calculated for each patient, for both positions (400 tracking sessions). Results: Clear patterns of respiratory motion were seen in the prone tracks due to the influence of increased abdominal motion. Averaged over all patients, the prostate was displaced >3 and 5 mm for 37.8% and 10.1% of the total tracking time in the prone position, respectively. In the supine position, the prostate was displaced >3 and 5 mm for 12.6% and 2.9%, respectively. With both patient setups, inferior and posterior drifts of the prostate position were observed. Averaged over all prone tracking sessions, the prostate was displaced >3 mm in the posterior and inferior directions for 11.7% and 9.5% of the total time, respectively. Conclusions: With real-time tracking of the prostate, it is possible to study the effects of different setup positions on the prostate mobility. The percentage of time the prostate moved >3 and 5 mm was increased by a factor of three in the prone versus supine position. For larger displacements (>7 mm) no difference in prostate mobility was observed between prone and supine positions. To reduce rectal toxicity, radiotherapy in the prone position may be a suitable alternative provided respiratory motion is accounted for during treatment. Acute and late toxicity results remain to be evaluated for both patient positions.

  13. Syndesmotic fixation in supination-external rotation ankle fractures: a prospective randomized study.

    Science.gov (United States)

    Pakarinen, Harri J; Flinkkilä, Tapio E; Ohtonen, Pasi P; Hyvönen, Pekka H; Lakovaara, Martti T; Leppilahti, Juhana I; Ristiniemi, Jukka Y

    2011-12-01

    This study was designed to assess whether transfixion of an unstable syndesmosis is necessary in supination-external rotation (Lauge-Hansen SE/Weber B)-type ankle fractures. A prospective study of 140 patients with unilateral Lauge-Hansen supination-external rotation type 4 ankle fractures was done. After bony fixation, the 7.5-Nm standardized external rotation (ER) stress test for both ankles was performed under fluoroscopy. A positive stress examination was defined as a difference of more than 2 mm side-to-side in the tibiotalar or tibiofibular clear spaces on mortise radiographs. If the stress test was positive, the patient was randomized to either syndesmotic transfixion with 3.5-mm tricortical screws or no syndesmotic fixation. Clinical outcome was assessed using the Olerud-Molander scoring system, RAND 36-Item Health Survey, and Visual Analogue Scale (VAS) to measure pain and function after a minimum 1-year of followup. Twenty four (17%) of 140 patients had positive standardized 7.5-Nm ER stress tests after malleolar fixation. The stress view was positive three times on tibiotalar clear space, seven on tibiofibular clear space, and 14 times on both tibiotalar and tibiofibular clear spaces. There was no significant difference between the two randomization groups with regards to Olerud-Molander functional score, VAS scale measuring pain and function, or RAND 36-Item Health Survey pain or physical function at 1 year. Relevant syndesmotic injuries are rare in supination-external rotation ankle fractures, and syndesmotic transfixion with a screw did not influence the functional outcome or pain after the 1-year followup compared with no fixation.

  14. Impact of body position on central and peripheral hemodynamic contributions to movement-induced hyperemia: implications for rehabilitative medicine

    OpenAIRE

    Trinity, Joel D.; McDaniel, John; Venturelli, Massimo; Fjeldstad, Anette S.; Ives, Stephen J.; Witman, Melissa A. H.; Barrett-O'Keefe, Zachary; Amann, Markus; Wray, D. Walter; Richardson, Russell S.

    2011-01-01

    This study used alterations in body position to identify differences in hemodynamic responses to passive exercise. Central and peripheral hemodynamics were noninvasively measured during 2 min of passive knee extension in 14 subjects, whereas perfusion pressure (PP) was directly measured in a subset of 6 subjects. Movement-induced increases in leg blood flow (LBF) and leg vascular conductance (LVC) were more than twofold greater in the upright compared with supine positions (LBF, supine: 462 ±...

  15. Media Representation of the Human Body: Discourse Analysis of Advertisements

    Directory of Open Access Journals (Sweden)

    Marija Lončar

    2015-09-01

    Full Text Available Even though advertisements represent a world of its own, they are an inevitable part of different kinds of media. The purpose of advertising is not only to promote a product but also to transfer messages, values and ideas in order to make emotional connections with brands. By building emotional attachment, advertisers increase and strengthen consumers’ responses. The promoting of the advertisements’ images becomes much more important than promoting the product itself. Nowadays, an increasing interest in representing a human body along with different kinds of products and services has become a commonplace among advertisers. Representation of the body is a socially constructed phenomenon. In other words, social processes shape perceptions of our bodies and these perceptions (recreate human experiences of the body. The authors’ approach includes qualitative discourse analysis of advertisements. The objective was to identify the relationship between the human body and textual messages as integral components of the advertised item taken in consideration, as well as the ways in which they interact with the reader’s overall experience. For this purpose, different advertisements that contain visual and textual messages representing human bodies have been analysed. They were all published in the following lifestyle magazines: Cosmopolitan, Playboy, Men’s Health, during 2012 and 2013. The authors conclude that media representations of a human body as social phenomena perceive value and treat the body in different ways depending on the relationship between the advertisement, the textual message and the human body.

  16. Evaluation of Propagation Characteristics Using the Human Body as an Antenna.

    Science.gov (United States)

    Li, Jingzhen; Nie, Zedong; Liu, Yuhang; Wang, Lei; Hao, Yang

    2017-12-11

    In this paper, an inhomogeneous human body model was presented to investigate the propagation characteristics when the human body was used as an antenna to achieve signal transmission. Specifically, the channel gain of four scenarios, namely, (1) both TX electrode and RX electrode were placed in the air, (2) TX electrode was attached on the human body, and RX electrode was placed in the air, (3) TX electrode was placed in the air, and RX electrode was attached on the human body, (4) both the TX electrode and RX electrode were attached on the human body, were studied through numerical simulation in the frequency range 1 MHz to 90 MHz. Furthermore, the comparisons of input efficiency, accepted efficiency, total efficiency, absorption power of human body, and electric field distribution of different distances of four aforementioned scenarios were explored when the frequency was at 44 MHz. In addition, the influences of different human tissues, electrode position, and the distance between electrode and human body on the propagation characteristics were investigated respectively at 44 MHz. The results showed that the channel gain of Scenario 4 was the maximum when the frequency was from 1 MHz to 90 MHz. The propagation characteristics were almost independent of electrode position when the human body was using as an antenna. However, as the distance between TX electrode and human body increased, the channel gain decreased rapidly. The simulations were verified by experimental measurements. The results showed that the simulations were in agreement with the measurements.

  17. Effect of Recumbent Body Positions on Dynamic Lung Function Parameters in Healthy Young Subjects.

    Science.gov (United States)

    Pal, Arvind Kumar; Tiwari, Sunita; Verma, Dileep Kumar

    2017-05-01

    The change in body position can alter pulmonary functions parameters, therefore it is important to understand the physiological basis of these alteration. Ideally, spirometry is done in sitting position until the subject is unable to do so. Hospitalized patients often assume recumbent body positions irrespective of underlying pathology. Hence, need arises to find out best recumbent body positions for the benefit of these patients to make breathing comfortable for them. The aim of this study was to find out whether the change from the supine position to crook lying and Fowler's position (45° dorsal elevation) causes change in spirometric parameters. The present work was carried out at Department of Physiology, King George's Medical University, Lucknow. A total 131 apparently healthy individuals were enrolled in this cross-sectional study. Lung function was assessed using a PC-based spirometer according to American Thoracic Society guideline in the supine, crook lying and Fowler's position (45° dorsal elevation). The study consisted of 131 subjects (male 66%, female 34%), with mean age of 20.15±2.71 years and BMI 21.20±3.28 Kg/m 2 . Repeated measures ANOVA with post hoc Bonferroni test was used to compare the mean values between each body position. Compared with the other two positions, Fowler's position showed significantly (p<0.05) higher values for FVC, FEV 1 , PEF, FEF 25-75% . Recumbent body position influences spirometric parameters in young healthy subjects. We demonstrated that spirometric values are higher in the Fowler's position than in the supine or crook lying position. The results of this study will help in the selection of the best alternative position for the spirometry in bed ridden patients.

  18. Dynamic Human Body Modeling Using a Single RGB Camera.

    Science.gov (United States)

    Zhu, Haiyu; Yu, Yao; Zhou, Yu; Du, Sidan

    2016-03-18

    In this paper, we present a novel automatic pipeline to build personalized parametric models of dynamic people using a single RGB camera. Compared to previous approaches that use monocular RGB images, our system can model a 3D human body automatically and incrementally, taking advantage of human motion. Based on coarse 2D and 3D poses estimated from image sequences, we first perform a kinematic classification of human body parts to refine the poses and obtain reconstructed body parts. Next, a personalized parametric human model is generated by driving a general template to fit the body parts and calculating the non-rigid deformation. Experimental results show that our shape estimation method achieves comparable accuracy with reconstructed models using depth cameras, yet requires neither user interaction nor any dedicated devices, leading to the feasibility of using this method on widely available smart phones.

  19. Human bipedalism and body-mass index.

    Science.gov (United States)

    Yi, Su Do; Noh, Jae Dong; Minnhagen, Petter; Song, Mi-Young; Chon, Tae-Soo; Kim, Beom Jun

    2017-06-16

    Body-mass index, abbreviated as BMI and given by M/H 2 with the mass M and the height H, has been widely used as a useful proxy to measure a general health status of a human individual. We generalise BMI in the form of M/H p and pursue to answer the question of the value of p for populations of animal species including human. We compare values of p for several different datasets for human populations with the ones obtained for other animal populations of fish, whales, and land mammals. All animal populations but humans analyzed in our work are shown to have p ≈ 3 unanimously. In contrast, human populations are different: As young infants grow to become toddlers and keep growing, the sudden change of p is observed at about one year after birth. Infants younger than one year old exhibit significantly larger value of p than two, while children between one and five years old show p ≈ 2, sharply different from other animal species. The observation implies the importance of the upright posture of human individuals. We also propose a simple mechanical model for a human body and suggest that standing and walking upright should put a clear division between bipedal human (p ≈ 2) and other animals (p ≈ 3).

  20. Functional Neuronal Processing of Human Body Odors

    OpenAIRE

    Lundström, Johan N.; Olsson, Mats J.

    2010-01-01

    Body odors carry informational cues of great importance for individuals across a wide range of species, and signals hidden within the body odor cocktail are known to regulate several key behaviors in animals. For a long time, the notion that humans may be among these species has been dismissed. We now know, however, that each human has a unique odor signature that carries information related to his or her genetic makeup, as well as information about personal environmental variables, such as d...

  1. Human whole body cold adaptation.

    OpenAIRE

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    ABSTRACT Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000?y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations...

  2. Human Body Representations in Didactic Books of Science

    Directory of Open Access Journals (Sweden)

    Emerson de Lima Soares

    2018-01-01

    Full Text Available Several authors have pointed out that Didactic Book still plays an important role in the teaching and learning process, and is often the main, and the only educational resource available to teachers. In this way, we will analyze human body representations in Didactic Books of science adopted by a municipal public school in the city of Uruguaiana/RS. In the context of writing, we understand that body's perceptions permeate a historical and cultural construction, constituted from the relationships lived by the subjects in society. This study is a qualitative research, based on the content analysis of Bardin, in which we seek to identify human body representations in the messages, characteristics, structures, contents, and figures present in books. For this, we set up an analytical matrix with guiding questions related to the approach of the body, showed in didactic books. The results demonstrate that the contents follow the same pattern, that is, a body divided into parts like a human body just formed by limbs, organs, and tissues. They present a detailed division of content, from the cellular organization, concepts, structures, and the images are presented in a fragmented way, always following normative standards. We found these books dedicate spaces to analyze and discuss the biosocial body, in a well-elaborated way, contemplating different visions, such as sexuality beyond human reproduction. We believe that these issues should be part of the Political Education Projects (PPPs of schools and the educational system as a whole because in this way more projects will be carried out contemplating the issue. However, it is still up to the teacher to take this approach, and if such issues are not addressed in the LD, he should keep in mind that if we are thinking beings, our body is much more than organic components, and so seek means to carry out this approach.

  3. Human whole body cold adaptation.

    NARCIS (Netherlands)

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced

  4. NATURAL USER INTERFACE SENSORS FOR HUMAN BODY MEASUREMENT

    Directory of Open Access Journals (Sweden)

    J. Boehm

    2012-08-01

    Full Text Available The recent push for natural user interfaces (NUI in the entertainment and gaming industry has ushered in a new era of low cost three-dimensional sensors. While the basic idea of using a three-dimensional sensor for human gesture recognition dates some years back it is not until recently that such sensors became available on the mass market. The current market leader is PrimeSense who provide their technology for the Microsoft Xbox Kinect. Since these sensors are developed to detect and observe human users they should be ideally suited to measure the human body. We describe the technology of a line of NUI sensors and assess their performance in terms of repeatability and accuracy. We demonstrate the implementation of a prototype scanner integrating several NUI sensors to achieve full body coverage. We present the results of the obtained surface model of a human body.

  5. Natural User Interface Sensors for Human Body Measurement

    Science.gov (United States)

    Boehm, J.

    2012-08-01

    The recent push for natural user interfaces (NUI) in the entertainment and gaming industry has ushered in a new era of low cost three-dimensional sensors. While the basic idea of using a three-dimensional sensor for human gesture recognition dates some years back it is not until recently that such sensors became available on the mass market. The current market leader is PrimeSense who provide their technology for the Microsoft Xbox Kinect. Since these sensors are developed to detect and observe human users they should be ideally suited to measure the human body. We describe the technology of a line of NUI sensors and assess their performance in terms of repeatability and accuracy. We demonstrate the implementation of a prototype scanner integrating several NUI sensors to achieve full body coverage. We present the results of the obtained surface model of a human body.

  6. Human body composition models and methodology : theory and experiment

    NARCIS (Netherlands)

    Wang, Z.M.

    1997-01-01


    The study of human body composition is a branch of human biology which focuses on the in vivo quantification of body components, the quantitative relationships between components, and the quantitative changes in these components related to various influencing factors.

  7. Effect of the Stroop test performed in supine position on the heart rate variability in both genders.

    Science.gov (United States)

    Vazan, Rastislav; Filcikova, Diana; Mravec, Boris

    2017-12-01

    The effect of Stroop test (ST)-induced stress on autonomic nervous system activity is often examined via measurement of heart rate variability (HRV). However, HRV may be significantly affected by interfering factors, including vocalization and inappropriate body position. Surprisingly, published studies ignore these issues, so the aim of our study was to test the innovative procedure for correct HRV measurement in individuals exposed to ST. Moreover, we examined possible gender differences in HRV and heart rate (HR) during ST. Healthy participants (21 men, 34 women) were placed in a supine position (no orthostatic activation) and then exposed to a 5 min relaxation period and a 5 min period of computerized ST (no vocalization). We found significant differences in HR and HRV parameters in both genders during ST when compared to relaxation (baseline) values. On the other hand, there were no significant differences in HR and HRV between males and females (except for a higher baseline HR in women). Also, reactivity to ST stress (difference between baseline and ST value) showed no gender differences. In conclusion, when performed in a supine position and without vocalization, the ST induces significant stress-related changes of HR and HRV in both genders, with no gender differences in the magnitude of reaction to ST stress. This experimental procedure can be used for correct examination of mental stress-related changes in the autonomic nervous system, and is particularly useful for examining mixed-gender experimental groups. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Cytoplasmic lipid bodies of human neutrophilic leukocytes

    International Nuclear Information System (INIS)

    Weller, P.F.; Ackerman, S.J.; Nicholson-Weller, A.; Dvorak, A.M.

    1989-01-01

    The morphology and function of cytoplasmic lipid bodies in human neutrophils were evaluated. By transmission electron microscopy, neutrophil lipid bodies were cytoplasmic inclusions, usually several microns in diameter, that occasionally coalesced to attain a diameter up to 7 microM. Neutrophil lipid bodies were not enveloped by membrane but were often surrounded by a more electron-dense shell at their periphery. Normal peripheral blood neutrophils contained an average of approximately one lipid body per cell. Lipid bodies appeared in greater numbers in neutrophils from inflammatory lesions. Perturbation of neutrophils during conventional methods of cell isolation and purification modestly increased lipid body numbers in neutrophils, whereas incubation of neutrophils with 1 microM oleic acid rapidly induced lipid body formation over 30 to 60 minutes. After granulocytes were incubated for 2 hours with 3H-fatty acids, including arachidonic, oleic, and palmitic acids, electron microscopic autoradiography demonstrated that lipid bodies represented the predominant intracellular sites of localization of each of the three 3H-fatty acids. There was lesser labeling noted in the perinuclear cisterna, but not in cell membranes. Virtually all of each of the three 3H-fatty acids incorporated by the neutrophils were esterified into chromatographically resolved classes of neutral lipids or phospholipids. These findings indicate that cytoplasmic lipid bodies are more prominent in neutrophils in vivo engaged in inflammatory responses and that these organelles in human neutrophils function as sites of deposition of esterified, incorporated fatty acids

  9. What happens to the triangular fibrocartilage complex during pronation and supination of the forearm? Analysis of its morphology and diagnostic assessment with MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Pfirrmann, C.W.A. [Dept. of Radiology, Veterans Administration Medical Center, San Diego, CA (United States); Dept. of Radiology, Orthopedic University Hospital Balgrist, Zurich (Switzerland); Theumann, N.H. [Dept. of Radiology, Veterans Administration Medical Center, San Diego, CA (United States); Service de Radiologie, CHUV, Lausanne (Switzerland); Chung, C.B.; Trudell, D.J.; Resnick, D. [Dept. of Radiology, Veterans Administration Medical Center, San Diego, CA (United States); Botte, M.J. [Div. of Orthopedic Surgery, Scripps Clinic and Research Foundation, La Jolla, CA (United States)

    2001-12-01

    Objective: To evaluate the dynamic morphologic changes of the triangular fibrocartilage complex (TFCC) during pronation and supination of the forearm using high-resolution MR arthrography in cadavers and to evaluate the impact of these changes on the diagnostic assessment of the normal and abnormal TFCC. Design and specimens: High-resolution MR arthrography of 10 wrists of cadaveric specimens was obtained in maximum pronation, in the neutral position, and in maximum supination of the forearm. The structures of the TFCC were evaluated by two musculoskeletal radiologists and correlated with anatomic sections. The position of the forearm that allowed the best visualization of normal structures and lesions of the TFCC was determined. Results: The shape and extent of the articular disc as well as the radial portions of the radioulnar ligaments did not change with pronation and supination. The articular disc was horizontal in the neutral position and tilted more distally to align with the proximal carpal row in pronation and supination. The fibers of the ulnar part of the radioulnar ligaments (ulnar attachment of the articular disc) revealed the most significant changes: their orientation was coronal in the neutral position and sagittal in positions of pronation and supination. The ulnomeniscal homologue was largest in the neutral position and was reduced in size during pronation and supination. The extensor carpi ulnaris tendon was centered in its groove in the neutral position and pronation. In supination this tendon revealed subluxation from this groove. The dorsal capsule of the distal radioulnar joint was taut in pronation, and the palmar capsule was taut in supination. The preferred forearm position for analysis of most of the structures of the TFCC was the neutral position, followed by the pronated position. The neutral position was rated best for the detection of ulnar and radial detachments of the TFCC, followed by the pronated position, except for two central

  10. New Window into the Human Body

    Science.gov (United States)

    1985-01-01

    Michael Vannier, MD, a former NASA engineer, recognized the similarity between NASA's computerized image processing technology and nuclear magnetic resonance. With technical assistance from Kennedy Space Center, he developed a computer program for Mallinckrodt Institute of Radiology enabling Nuclear Magnetic Resonance (NMR) to scan body tissue for earlier diagnoses. Dr. Vannier feels that "satellite imaging" has opened a new window into the human body.

  11. Comparison of the Effects of Seated, Supine, and Walking Interset Rest Strategies on Work Rate.

    Science.gov (United States)

    Ouellette, Kristen A; Brusseau, Timothy A; Davidson, Lance E; Ford, Candus N; Hatfield, Disa L; Shaw, Janet M; Eisenman, Patricia A

    2016-12-01

    Ouellette, KA, Brusseau, TA, Davidson, LE, Ford, CN, Hatfield, DL, Shaw, JM, and Eisenman, PA. Comparison of the effects of seated, supine, and walking interset rest strategies on work rate. J Strength Cond Res 30(12): 3396-3404, 2016-The idea that an upright posture should be maintained during the interset rest periods of training sessions is pervasive. The primary aim of this study was to determine differences in work rate associated with 3 interset rest strategies. Male and female members of the CrossFit community (male n = 5, female n = 10) were recruited to perform a strenuous training session designed to enhance work capacity that involved both cardiovascular and muscular endurance exercises. The training session was repeated on 3 separate occasions to evaluate 3 interset rest strategies, which included lying supine on the floor, sitting on a flat bench, and walking on a treadmill (0.67 m·s). Work rate was calculated for each training session by summing session joules of work and dividing by the time to complete the training session (joules of work per second). Data were also collected during the interset rest periods (heart rate [HR], respiratory rate [RR], and volume of oxygen consumed) and were used to explain why one rest strategy may positively impact work rate compared with another. Statistical analyses revealed significant differences (p ≤ 0.05) between the passive and active rest strategies, with the passive strategies allowing for improved work rate (supine = 62.77 ± 7.32, seated = 63.66 ± 8.37, and walking = 60.61 ± 6.42 average joules of work per second). Results also suggest that the passive strategies resulted in superior HR, RR, and oxygen consumption recovery. In conclusion, work rate and physiological recovery were enhanced when supine and seated interset rest strategies were used compared with walking interset rest.

  12. Anthropometric Renal Anatomic Alterations Between Supine and Prone Positions in Percutaneous Renal Ablation for Renal Cortical Neoplasms.

    Science.gov (United States)

    Lusch, Achim; Fujimoto, Scott; Findeiss, Laura K; Okhunov, Zhamshid; McDougall, Elspeth M; Landman, Jaime

    2016-02-01

    To establish patterns of anatomic changes relevant to the kidney and colon during positional change between the supine and prone positions as noted on CT scans performed during percutaneous cryoablation for renal cortical neoplasms (RCN). Nineteen patients undergoing percutaneous cryoablation for RCN with abdominal CT scan in both the supine and prone positions were included in the study. We documented the anterior/posterior, medial/lateral, and cranial/caudal anatomic changes of the kidney, kidney rotation, and the proportion of the kidney whose access was limited by the liver, spleen, and lung. We also calculated the length of the percutaneous access tract and the distance between the colon and kidney in hilar position as well as the anterior/posterior location of the colon relative to the kidney. In the prone position, the kidney lies significantly more anteriorly on both sides: 4.7 cm vs 4.3 cm (L) and 4.4 cm vs 4.1 cm (R) (p = 0.02 and p = 0.03, respectively). On prone CT images, both kidneys are more cranial when compared with the supine position: 80.4 mm vs 60.8 mm (L) and 87.2 mm vs 57.4 mm (R) (p = 0.002 and p anatomic alterations between supine and prone CT imaging. The changes associated with the prone position modify percutaneous access, particularly for right upper pole tumors. Prone imaging before surgery may be helpful in selected cases.

  13. Target volume shape variation during irradiation of rectal cancer patients in supine position: Comparison with prone position

    International Nuclear Information System (INIS)

    Nijkamp, Jasper; Jong, Rianne de; Sonke, Jan-Jakob; Vliet, Corine van; Marijnen, Corrie

    2009-01-01

    Purpose: To quantify the inter-fraction shape variation of the mesorectum for rectal cancer patients treated with 5 x 5 Gy in supine position and compare it to variation in prone position. Methods and materials: For 28 patients a planning CT (pCT) and five daily cone-beam-CT (CBCT) scans were acquired in supine position. The mesorectal part of the CTV (MesoRect) was delineated on all scans. The shape variation was quantified by the distance between the pCT- and the CBCT delineations and stored in surface maps after online setup correction. Data were analyzed for male and female patients separately and compared to prone data. Results: A large range of systematic, 1-8 mm (1SD), and random, 1-5 mm, shape variation was found, comparable to prone patients. Random-shape variation was comparable for male and female patients, while systematic variation was 3 mm larger for female patients. Conclusions: Shape variation of the MesoRect is substantial, heterogeneous and different between male and female patients. Differences between supine and prone orientation, however, are small. Clinical margins should be differentiated in position along the cranio-caudal axis, in anterior-posterior direction and for gender. Margins should also be increased, even when online setup correction is used. Due to the small margin differences between prone and supine treatments, the setup choice should be determined on dose to the organs at risk.

  14. Human whole body cold adaptation.

    Science.gov (United States)

    Daanen, Hein A M; Van Marken Lichtenbelt, Wouter D

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000 y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations, but also physiological adaptations to cold. Dedicated studies show that repeated whole body exposure of individual volunteers, mainly Caucasians, to severe cold results in reduced cold sensation but no major physiological changes. Repeated cold water immersion seems to slightly reduce metabolic heat production, while repeated exposure to milder cold conditions shows some increase in metabolic heat production, in particular non-shivering thermogenesis. In conclusion, human cold adaptation in the form of increased metabolism and insulation seems to have occurred during recent evolution in populations, but cannot be developed during a lifetime in cold conditions as encountered in temperate and arctic regions. Therefore, we mainly depend on our behavioral skills to live in and survive the cold.

  15. Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: Pilot study

    International Nuclear Information System (INIS)

    Li Ping; Napel, Sandy; Acar, Burak; Paik, David S.; Jeffrey, R. Brooke Jr.; Beaulieu, Christopher F.

    2004-01-01

    Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wall to be collapsed, covered with water, and/or covered with retained stool, patients are scanned in both prone and supine positions. We believe that both reading efficiency and computer aided detection (CAD) of CTC images can be improved by accurate registration of data from the supine and prone positions. We developed a two-stage approach that first registers the colonic central paths using a heuristic and automated algorithm and then matches polyps or polyp candidates (CAD hits) by a statistical approach. We evaluated the registration algorithm on 24 patient cases. After path registration, the mean misalignment distance between prone and supine identical anatomic landmarks was reduced from 47.08 to 12.66 mm, a 73% improvement. The polyp registration algorithm was specifically evaluated using eight patient cases for which radiologists identified polyps separately for both supine and prone data sets, and then manually registered corresponding pairs. The algorithm correctly matched 78% of these pairs without user input. The algorithm was also applied to the 30 highest-scoring CAD hits in the prone and supine scans and showed a success rate of 50% in automatically registering corresponding polyp pairs. Finally, we computed the average number of CAD hits that need to be manually compared in order to find the correct matches among the top 30 CAD hits. With polyp registration, the average number of comparisons was 1.78 per polyp, as opposed to 4.28 comparisons without polyp registration

  16. Effect of Body Position on Energy Expenditure of Preterm Infants as Determined by Simultaneous Direct and Indirect Calorimetry.

    Science.gov (United States)

    Bell, Edward F; Johnson, Karen J; Dove, Edwin L

    2017-04-01

    Background  Indirect calorimetry is the standard method for estimating energy expenditure in clinical research. Few studies have evaluated indirect calorimetry in infants by comparing it with simultaneous direct calorimetry. Our purpose was (1) to compare the energy expenditure of preterm infants determined by these two methods, direct calorimetry and indirect calorimetry; and (2) to examine the effect of body position, supine or prone, on energy expenditure. Study Design  We measured energy expenditure by simultaneous direct (heat loss by gradient-layer calorimeter corrected for heat storage) and indirect calorimetry (whole-body oxygen consumption and carbon dioxide production) in 15 growing preterm infants during two consecutive interfeeding intervals, once in the supine position and once in the prone position. Results  The mean energy expenditure for all measurements in both positions did not differ significantly by the method used: 2.82 (standard deviation [SD] 0.42) kcal/kg/h by direct calorimetry and 2.78 (SD 0.48) kcal/kg/h by indirect calorimetry. The energy expenditure was significantly lower, by 10%, in the prone than in the supine position, whether examined by direct calorimetry (2.67 vs. 2.97 kcal/kg/h, p  Direct calorimetry and indirect calorimetry gave similar estimates of energy expenditure. Energy expenditure was 10% lower in the prone position than in the supine position. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. Towards an IMU Evaluation Framework for Human Body Tracking.

    Science.gov (United States)

    Venek, Verena; Kremser, Wolfgang; Schneider, Cornelia

    2018-01-01

    Existing full-body tracking systems, which use Inertial Measurement Units (IMUs) as sensing unit, require expert knowledge for setup and data collection. Thus, the daily application for human body tracking is difficult. In particular, in the field of active and assisted living (AAL), tracking human movements would enable novel insights not only into the quantity but also into the quality of human movement, for example by monitoring functional training. While the current market offers a wide range of products with vastly different properties, literature lacks guidelines for choosing IMUs for body tracking applications. Therefore, this paper introduces developments towards an IMU evaluation framework for human body tracking which compares IMUs against five requirement areas that consider device features and data quality. The data quality is assessed by conducting a static and a dynamic error analysis. In a first application to four IMUs of different component consumption, the IMU evaluation framework convinced as promising tool for IMU selection.

  18. Reference values for total blood volume and cardiac output in humans

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L.R. [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

    1994-09-01

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

  19. Verification of supersonic and hypersonic semi-empirical predictions using CFD

    International Nuclear Information System (INIS)

    McIlwain, S.; Khalid, M.

    2004-01-01

    CFD was used to verify the accuracy of the axial force, normal force, and pitching moment predictions of two semi-empirical codes. This analysis considered the flow around the forebody of four different aerodynamic shapes. These included geometries with equal-volume straight or tapered bodies, with either standard or double-angle nose cones. The flow was tested at freestream Mach numbers of M = 1.5, 4.0, and 7.0. The CFD results gave the expected flow pressure contours for each geometry. The geometries with straight bodies produced larger axial forces, smaller normal forces, and larger pitching moments compared to the geometries with tapered bodies. The double-angle nose cones introduced a shock into the flow, but affected the straight-body geometries more than the tapered-body geometries. Both semi-empirical codes predicted axial forces that were consistent with the CFD data. The agreement between the normal forces and pitching moments was not as good, particularly for the straight-body geometries. But even though the semi-empirical results were not exactly the same as the CFD data, the semi-empirical codes provided rough estimates of the aerodynamic parameters in a fraction of the time required to perform a CFD analysis. (author)

  20. Digitization of the human body in the present-day economy

    Science.gov (United States)

    D'Apuzzo, Nicola

    2005-01-01

    In this paper we report on the historic development of human body digitization and on the actual state of commercially available technology. Complete systems for the digitization of the human body exist since more than ten years. One of the main users of this technology was the entertainment industry. Every new movie excited with attractive visual effects, but only few people knew that the most thrilling cuts were realized by using virtual persons. The faces and bodies of actors were digitized and the "virtual twin" replaced the actor in the movie. Nowadays, the state of the human body digitization is so high that it is not possible any more to distinguish the real actor from the virtual one. Indeed, for the rush technical development has to be thanked the movie industry, which was one of the strong economic motors for this technology. Today, with the possibility of a massive cost reduction given by new technologies, methods for digitization of the human body are used also in other fields of application, such as ergonomics, medical applications, computer games, biometry and anthropometrics. With the time, this technology becomes interesting also for sport, fitness, fashion and beauty. A large expansion of human body digitization is expected in the near future. To date, different technologies are used commercially for the measurement of the human body. They can be divided into three distinguished groups: laser-scanning, projection of light patterns, combination modeling and image processing. The different solutions have strengths and weaknesses that profile their suitability for specific applications. This paper gives an overview of their differences and characteristics and expresses clues for the selection of the adequate method. Practical examples of commercial exploitation of human body digitization are also presented and new interesting perspectives are introduced.

  1. Effect of reducing abdominal compression during prone CT colonography on ascending colonic rotation during supine-to-prone positional change

    International Nuclear Information System (INIS)

    Jang, Jong eon; Park, Seong Ho; Lee, Jong Seok; Kim, Hyun Jin; KIm, Ah Young; Ha, Hyun Kwon

    2016-01-01

    To determine the effect of reduced abdominal compression in prone position on ascending colonic movement during supine-to-prone positional change during CT colonography (CTC). Eighteen consecutive patients who had undergone prone CTC scanning with cushion blocks placed under the chest and hip/thigh to reduce abdominal compression and had confirmed sessile polyps ≥ 6 mm in the well-distended, straight, mid-ascending colon, were included. Radial location along the ascending colonic luminal circumference (°) was measured for 24 polyps and 54 colonic teniae on supine and prone CTC images. The supine-to-prone change ranging between -180° and +180° (- and + for internal and external colonic rotations, respectively), was determined. In addition, possible causes of any ascending colonic rotations were explored. Abdominal compression during prone CTC scanning completely disappeared with the use of cushion blocks in 17 of 18 patients. However, some degrees of ascending colonic rotation were still observed, with the radial location changes of -22° to 61° (median, 13.9°) for the polyps and similar degrees for teniae. Fifty-four percent and 56% of polyps and teniae, respectively, showed changes > 10°. The radial location change of the polyps was significantly associated with the degree of anterior shift of the small bowel and mesentery (r = 0.722, p < 0.001) and the degree of posterior displacement of the ascending colon (r = 0.566, p = 0.004) during supine-to-prone positional change. Ascending colonic rotation upon supine-to-prone positional change during CTC, mostly in the form of external rotation, is not eliminated by removing abdominal compression in prone position

  2. Consideration of Shoulder Joint's Image with the Changed Tube Angle of the Shoulder Oblique Projection in Supine Position

    International Nuclear Information System (INIS)

    Seo, Jae Hyun; Choi, Nam Gil

    2008-01-01

    There is a standard shoulder oblique method (Grashey method) available to view the shoulder joint. This method projects AP view of the shoulder joint so that the Humerus head's subuxation or joint degeneration can be easily visualized. However, in this view, the patients, with supine or sitting or erect position, have to keep their body obliquely. Whereas, the patients who are not well or operated, usually feel very uncomfortable to keep their body in this position and hence, we need other persons' help and much efforts will be needed to get the good quality shoulder joint view. Therefore, we thought of examining a method which shows the joint well by angling the tube to Medio-Lateral direction and without keeping the patients' one side upward in supine position. For this study, total 15 subjects with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 9 males and 6 females. Statistic group analysis was performed with ANOVA test. Scores of the evaluation of the experts were 1.01±0.54 at 25 degrees, 2.50±0.50 at 30 degrees, 2.85±0.36 at 35 degrees and 2.33±0.47 at 40 degrees, respectively, and they were significant(p<0.05, Table 1). Joint space of the Humerus head and Scapula were well distinguished at 35 degrees, 30 degrees and 40 degrees with the almost same score. However, the degree of distortion at 40 degrees was more severe than that at 30 degrees. Ultimately, 30-35 degrees views were shown to yield good quality shoulder oblique images. In conclusion, this method may be very useful for the patients who are uncomfortable and for the emergency patients. In order to get similar or comparable view, the same X-tube angle is recommended to be used before and after the operation. Therefore, we hope that this new angled method seems to be efficient.

  3. Energy Generation in the Human Body by the Human Cells ...

    African Journals Online (AJOL)

    We adapted the thermodynamics equation for energy generation in a diesel engine in modeling energy generation in human body by the human cells by doing a thorough study on both systems and saw that the process of energy generation is the same in them. We equally saw that the stages involved in energy generation ...

  4. Dispersions in Semi-Classical Dynamics

    International Nuclear Information System (INIS)

    Zielinska-Pfabe, M.; Gregoire, C.

    1987-01-01

    Dispersions around mean values of one-body observables are obtained by restoring classical many-body correlations in Vlasov and Landau-Vlasov dynamics. The method is applied to the calculation of fluctuations in mass, charge and linear momentum in heavy-ion collisions. Results are compared to those obtained by the Balian-Veneroni variational principle in semi-classical approximation

  5. Injury to the human body, part 2

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Injuries by exposure to the atomic bomb at Hiroshima and Nagasaki and its effects were studied as follows: 1) Injury to the human body following exposure to the atomic bomb; 2) Body injury in the initial stage-acute stage of atomic bomb injury; 3) Aftereffects and genetic effects. (J.P.N.)

  6. Study on the exchangeable body sodium in diabetes mellitus

    International Nuclear Information System (INIS)

    de Chatel, Rudolf; Barna, Istvan; Krasznai, Istvan

    1985-01-01

    Ten patients with diabetes mellitus, apperently free of any complications of diabetes and of hypertension, had a significantly (p<0.01) increased exchangeable body sodium compared to 10 sex-matched control subjects of comparable age, body weight and height, and blood pressure. Exchangeable sodium correlated significantly (p<0.01) with supine mean blood pressure in the diabetic patients (r=0.822) but not in the control subjects (r=0.276). It is suggested that the early increase of exchangeable body sodium in diabetes mellitus might play a part in the high incidence of hypertension in such patients. (author)

  7. Experimental investigation of biodynamic human body models subjected to whole-body vibration during a vehicle ride.

    Science.gov (United States)

    Taskin, Yener; Hacioglu, Yuksel; Ortes, Faruk; Karabulut, Derya; Arslan, Yunus Ziya

    2018-02-06

    In this study, responses of biodynamic human body models to whole-body vibration during a vehicle ride were investigated. Accelerations were acquired from three different body parts, such as the head, upper torso and lower torso, of 10 seated passengers during a car ride while two different road conditions were considered. The same multipurpose vehicle was used during all experiments. Additionally, by two widely used biodynamic models in the literature, a set of simulations were run to obtain theoretical accelerations of the models and were compared with those obtained experimentally. To sustain a quantified comparison between experimental and theoretical approaches, the root mean square acceleration and acceleration spectral density were calculated. Time and frequency responses of the models demonstrated that neither of the models showed the best prediction performance of the human body behaviour in all cases, indicating that further models are required for better prediction of the human body responses.

  8. "Scientific peep show": the human body in contemporary science museums.

    Science.gov (United States)

    Canadelli, Elena

    2011-01-01

    The essay focuses on the discourse about the human body developed by contemporary science museums with educational and instructive purposes directed at the general public. These museums aim mostly at mediating concepts such as health and prevention. The current scenario is linked with two examples of past museums: the popular anatomical museums which emerged during the 19th century and the health museums thrived between 1910 and 1940. On the museological path about the human body self-care we went from the emotionally involving anatomical Venuses to the inexpressive Transparent Man, from anatomical specimens of ill organs and deformed subjects to the mechanical and electronic models of the healthy body. Today the body is made transparent by the new medical diagnostics and by the latest discoveries of endoscopy. The way museums and science centers presently display the human body involves computers, 3D animation, digital technologies, hands-on models of large size human parts.

  9. Transport of gaseous pollutants around a human body in quiescent indoor environment

    DEFF Research Database (Denmark)

    Licina, Dusan; Melikov, Arsen Krikor; Mioduszewski, Pawel

    2014-01-01

    (CBL) to transport the pollution in quiescent indoor environment. A human body is resembled by a thermal manikin with a body shape and surface temperature distribution of a real person. The objective of the study is to examine the impact of the pollutant location around the human body on the pollution...... concentration levels in the breathing zone. The results show that the location of the pollution source has a considerable influence of the breathing zone concentrations. This is contributed to the human CBL, as it pulls the pollution emitted close to the human body and transports it to the breathing zone...... the human body should be recognized in ventilation design practice....

  10. The Human Body Sword

    Directory of Open Access Journals (Sweden)

    Kris Borer

    2010-08-01

    Full Text Available The human body shield problem involves an apparent dilemma for a libertarian, forcing him to choose between his own death and the death of an innocent person. This paper argues that the non-aggression principle permits a forceful response against the property of innocent individuals when a conflict is initiated with that property. In other words, a libertarian may shoot the hostage in order to save himself.

  11. Rapid intravenous infusion of 20 mL/kg saline alters the distribution of perfusion in healthy supine humans.

    Science.gov (United States)

    Henderson, A C; Sá, R C; Barash, I A; Holverda, S; Buxton, R B; Hopkins, S R; Prisk, G K

    2012-03-15

    Rapid intravenous saline infusion, a model meant to replicate the initial changes leading to pulmonary interstitial edema, increases pulmonary arterial pressure in humans. We hypothesized that this would alter lung perfusion distribution. Six healthy subjects (29 ± 6 years) underwent magnetic resonance imaging to quantify perfusion using arterial spin labeling. Regional proton density was measured using a fast-gradient echo sequence, allowing blood delivered to the slice to be normalized for density and quantified in mL/min/g. Contributions from flow in large conduit vessels were minimized using a flow cutoff value (blood delivered > 35% maximum in mL/min/cm(3)) in order to obtain an estimate of blood delivered to the capillary bed (perfusion). Images were acquired supine at baseline, after infusion of 20 mL/kg saline, and after a short upright recovery period for a single sagittal slice in the right lung during breath-holds at functional residual capacity. Thoracic fluid content measured by impedance cardiography was elevated post-infusion by up to 13% (pchanges in conduit vessels, there were no significant changes in perfusion in dependent lung following infusion (7.8 ± 1.9 mL/min/g baseline, 7.9 ± 2.0 post, 8.5 ± 2.1 recovery, p=0.36). There were no significant changes in lung density. These data suggest that saline infusion increased perfusion to nondependent lung, consistent with an increase in intravascular pressures. Dependent lung may have been "protected" from increases in perfusion following infusion due to gravitational compression of the pulmonary vasculature. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. High School Students' Understanding of the Human Body System

    Science.gov (United States)

    Assaraf, Orit Ben-Zvi; Dodick, Jeff; Tripto, Jaklin

    2013-01-01

    In this study, 120 tenth-grade students from 8 schools were examined to determine the extent of their ability to perceive the human body as a system after completing the first stage in their biology curriculum--"The human body, emphasizing homeostasis". The students' systems thinking was analyzed according to the STH thinking model, which roughly…

  13. Human vocal attractiveness as signaled by body size projection.

    Directory of Open Access Journals (Sweden)

    Yi Xu

    Full Text Available Voice, as a secondary sexual characteristic, is known to affect the perceived attractiveness of human individuals. But the underlying mechanism of vocal attractiveness has remained unclear. Here, we presented human listeners with acoustically altered natural sentences and fully synthetic sentences with systematically manipulated pitch, formants and voice quality based on a principle of body size projection reported for animal calls and emotional human vocal expressions. The results show that male listeners preferred a female voice that signals a small body size, with relatively high pitch, wide formant dispersion and breathy voice, while female listeners preferred a male voice that signals a large body size with low pitch and narrow formant dispersion. Interestingly, however, male vocal attractiveness was also enhanced by breathiness, which presumably softened the aggressiveness associated with a large body size. These results, together with the additional finding that the same vocal dimensions also affect emotion judgment, indicate that humans still employ a vocal interaction strategy used in animal calls despite the development of complex language.

  14. Single-staged uniportal VATS in the supine position for simultaneous bilateral primary spontaneous pneumothorax.

    Science.gov (United States)

    Kim, Kyung Soo

    2017-05-15

    Simultaneous bilateral primary spontaneous pneumothorax (SBPSP) is rare, but requires surgery on both sides, in patients with definite bilateral bullae to prevent life-threatening conditions. Recently, uniportal video-assisted thoracoscopic surgery (VATS) has been widely accepted as a less invasive technique for the treatment of pneumothorax. Thus, we introduced single-staged uniportal VATS technique in the supine position, for the management of two cases of SBPSP. A 17-year-old boy presented with bilateral spontaneous pneumothorax and he underwent single-staged uniportal VATS in the supine position. Single wide draping in consecutive bilateral approaches removes the needs of changing patients' position. Whole thoracoscopic procedure for wedge resection of bullae lesions was conducted without difficulty. The total operation time took 65 min and the patient discharged 3 days after the operation. The patient was followed for 24 months without recurrence of both sides. Another 18-year-old boy was admitted with bilateral spontaneous pneumothorax and single-staged uniportal VATS was also performed in the supine position. The total operation time took 79 min and the patient discharged on postoperative day 4. He was followed for 19 months without recurrence of both sides. Single-staged uniportal VATS approach yielded satisfactory results from simplicity that not requires position change compared to conventional multi-ports VATS in the lateral position, and with better cosmetics. This technique is thought to be a feasible procedure in selective patients with SBPSP or with contralateral bullae for preventive role.

  15. Relationship between alertness, performance, and body temperature in humans

    Science.gov (United States)

    Wright, Kenneth P Jr; Hull, Joseph T.; Czeisler, Charles A.

    2002-01-01

    Body temperature has been reported to influence human performance. Performance is reported to be better when body temperature is high/near its circadian peak and worse when body temperature is low/near its circadian minimum. We assessed whether this relationship between performance and body temperature reflects the regulation of both the internal biological timekeeping system and/or the influence of body temperature on performance independent of circadian phase. Fourteen subjects participated in a forced desynchrony protocol allowing assessment of the relationship between body temperature and performance while controlling for circadian phase and hours awake. Most neurobehavioral measures varied as a function of internal biological time and duration of wakefulness. A number of performance measures were better when body temperature was elevated, including working memory, subjective alertness, visual attention, and the slowest 10% of reaction times. These findings demonstrate that an increased body temperature, associated with and independent of internal biological time, is correlated with improved performance and alertness. These results support the hypothesis that body temperature modulates neurobehavioral function in humans.

  16. Human and animal sounds influence recognition of body language.

    Science.gov (United States)

    Van den Stock, Jan; Grèzes, Julie; de Gelder, Beatrice

    2008-11-25

    In naturalistic settings emotional events have multiple correlates and are simultaneously perceived by several sensory systems. Recent studies have shown that recognition of facial expressions is biased towards the emotion expressed by a simultaneously presented emotional expression in the voice even if attention is directed to the face only. So far, no study examined whether this phenomenon also applies to whole body expressions, although there is no obvious reason why this crossmodal influence would be specific for faces. Here we investigated whether perception of emotions expressed in whole body movements is influenced by affective information provided by human and by animal vocalizations. Participants were instructed to attend to the action displayed by the body and to categorize the expressed emotion. The results indicate that recognition of body language is biased towards the emotion expressed by the simultaneously presented auditory information, whether it consist of human or of animal sounds. Our results show that a crossmodal influence from auditory to visual emotional information obtains for whole body video images with the facial expression blanked and includes human as well as animal sounds.

  17. The influence of body position on Bielschowsky's test

    Directory of Open Access Journals (Sweden)

    Carlos R. Souza-Dias

    2014-04-01

    Full Text Available Purpose: To investigate the veracity of Jampolsky's statement that Bielschowsky's head tilt test is inverted if performed with the patient in the upside-down position and to interpret its neuromuscular mechanism. Methods: We present a series of 10 patients selected from a referred sample who were diagnosed with superior oblique paresis. Hypertropia was measured in the primary position, with the head erect and tilted toward both shoulders with the patient in the erect, supine, and upside-down positions. The last position was achieved by hanging the patient upside-down. Results: As expected, our results showed the veracity of Jampolsky's statement. The forced head tilt difference was inverted or significantly decreased when the test was performed in the upside-down position. Moreover, in all patients, Bielschowsky's phenomenon was neutralized in the supine body position, in which hypertropia with the head erect tended to vanish. In 3 patients, it disappeared completely. Conclusions: This study showed that, in patients with superior oblique paresis, differences in the extent of hypertropia in Bielschowsky's test tended to vanish when the test was performed with the patient in the supine position and invert when it was performed with the patient in the upside-down position.

  18. Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis

    International Nuclear Information System (INIS)

    Wang Shijun; Yao Jianhua; Liu Jiamin; Petrick, Nicholas; Van Uitert, Robert L.; Periaswamy, Senthil; Summers, Ronald M.

    2009-01-01

    Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice--Once supine and once prone--to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined by the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27±52.97 to 14.98 mm±11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline.

  19. Energetic and exergetic comparison of the human body for the summer season

    International Nuclear Information System (INIS)

    Caliskan, Hakan

    2013-01-01

    Highlights: • Energetic and exergetic comparison of the human body. • Usage of summer season data. • Calculation of entropy generation of the human body. • Thermal comfort. • Determining predicted mean vote rate and predicted percentage dissatisfied rate for the human comfort. - Abstract: The energy and exergy analyses are performed to the human body for the summer season of the Izmir city in Turkey. It is found that the metabolism energy and exergy rates are the major part of the human body’s energy generation. However, metabolism energy rate (58.326 W/m 2 ) is much higher than corresponding exergetic one (1.661 W/m 2 ). The maximum energy loss of the human body (70.59%) occurs due to heat exchange such as radiation, convection, and conduction. On the other hand, the maximum exergy loss of the human body happens due to exhaled humid air (6.393%), while the most of the total exergy is consumed by the human body (90.786%). Thermal comfort condition is also calculated. The Predicted Mean Vote (PMV) rate is found as 0.028 which means that the thermal sensation of the human body is called as comfortable. Furthermore, the Predicted Percentage Dissatisfied (PPD) rate is determined to be 5.017% which is low and shows the thermally dissatisfied people percentages

  20. Human cutaneous vascular responses to whole-body tilting, Gz centrifugation, and LBNP

    Science.gov (United States)

    Watenpaugh, Donald E.; Breit, Gregory A.; Buckley, Theresa M.; Ballard, Richard E.; Murthy, Gita; Hargens, Alan R.

    2004-01-01

    We hypothesized that gravitational stimuli elicit cardiovascular responses in the following order with gravitational stress equalized at the level of the feet, from lowest to highest response: short-(SAC) and long-arm centrifugation (LAC), tilt, and lower body negative pressure (LBNP). Up to 15 healthy subjects underwent graded application of the four stimuli. Laser-Doppler flowmetry measured regional skin blood flow. At 0.6 G(z) (60 mmHg LBNP), tilt and LBNP similarly reduced leg skin blood flow to approximately 36% of supine baseline levels. Flow increased back toward baseline levels at 80-100 mmHg LBNP yet remained stable during 0.8-1.0 G(z) tilt. Centrifugation usually produced less leg vasoconstriction than tilt or LBNP. Surprisingly, SAC and LAC did not differ significantly. Thigh responses were less definitive than leg responses. No gravitational vasoconstriction occurred in the neck. All conditions except SAC increased heart rate, according to our hypothesized order. LBNP may be a more effective and practical means of simulating cardiovascular effects of gravity than centrifugation.

  1. Heart-Rate Variability During Deep Sleep in World-Class Alpine Skiers: A Time-Efficient Alternative to Morning Supine Measurements.

    Science.gov (United States)

    Herzig, David; Testorelli, Moreno; Olstad, Daniela Schäfer; Erlacher, Daniel; Achermann, Peter; Eser, Prisca; Wilhelm, Matthias

    2017-05-01

    It is increasingly popular to use heart-rate variability (HRV) to tailor training for athletes. A time-efficient method is HRV assessment during deep sleep. To validate the selection of deep-sleep segments identified by RR intervals with simultaneous electroencephalography (EEG) recordings and to compare HRV parameters of these segments with those of standard morning supine measurements. In 11 world-class alpine skiers, RR intervals were monitored during 10 nights, and simultaneous EEGs were recorded during 2-4 nights. Deep sleep was determined from the HRV signal and verified by delta power from the EEG recordings. Four further segments were chosen for HRV determination, namely, a 4-h segment from midnight to 4 AM and three 5-min segments: 1 just before awakening, 1 after waking in supine position, and 1 in standing after orthostatic challenge. Training load was recorded every day. A total of 80 night and 68 morning measurements of 9 athletes were analyzed. Good correspondence between the phases selected by RR intervals vs those selected by EEG was found. Concerning root-mean-squared difference of successive RR intervals (RMSSD), a marker for parasympathetic activity, the best relationship with the morning supine measurement was found in deep sleep. HRV is a simple tool for approximating deep-sleep phases, and HRV measurement during deep sleep could provide a time-efficient alternative to HRV in supine position.

  2. Wave excited motion of a body floating on water confined between two semi-infinite ice sheets

    Science.gov (United States)

    Ren, K.; Wu, G. X.; Thomas, G. A.

    2016-12-01

    The wave excited motion of a body floating on water confined between two semi-infinite ice sheets is investigated. The ice sheet is treated as an elastic thin plate and water is treated as an ideal and incompressible fluid. The linearized velocity potential theory is adopted in the frequency domain and problems are solved by the method of matched eigenfunctions expansion. The fluid domain is divided into sub-regions and in each sub-region the velocity potential is expanded into a series of eigenfunctions satisfying the governing equation and the boundary conditions on horizontal planes including the free surface and ice sheets. Matching is conducted at the interfaces of two neighbouring regions to ensure the continuity of the pressure and velocity, and the unknown coefficients in the expressions are obtained as a result. The behaviour of the added mass and damping coefficients of the floating body with the effect of the ice sheets and the excitation force are analysed. They are found to vary oscillatorily with the wave number, which is different from that for a floating body in the open sea. The motion of the body confined between ice sheets is investigated, in particular its resonant behaviour with extremely large motion found to be possible under certain conditions. Standing waves within the polynya are also observed.

  3. Electric field prediction for a human body-electric machine system.

    Science.gov (United States)

    Ioannides, Maria G; Papadopoulos, Peter J; Dimitropoulou, Eugenia

    2004-01-01

    A system consisting of an electric machine and a human body is studied and the resulting electric field is predicted. A 3-phase induction machine operating at full load is modeled considering its geometry, windings, and materials. A human model is also constructed approximating its geometry and the electric properties of tissues. Using the finite element technique the electric field distribution in the human body is determined for a distance of 1 and 5 m from the machine and its effects are studied. Particularly, electric field potential variations are determined at specific points inside the human body and for these points the electric field intensity is computed and compared to the limit values for exposure according to international standards.

  4. Semi-Metric Topology of the Human Connectome: Sensitivity and Specificity to Autism and Major Depressive Disorder.

    Directory of Open Access Journals (Sweden)

    Tiago Simas

    Full Text Available The human functional connectome is a graphical representation, consisting of nodes connected by edges, of the inter-relationships of blood oxygenation-level dependent (BOLD time-series measured by MRI from regions encompassing the cerebral cortices and, often, the cerebellum. Semi-metric analysis of the weighted, undirected connectome distinguishes an edge as either direct (metric, such that there is no alternative path that is accumulatively stronger, or indirect (semi-metric, where one or more alternative paths exist that have greater strength than the direct edge. The sensitivity and specificity of this method of analysis is illustrated by two case-control analyses with independent, matched groups of adolescents with autism spectrum conditions (ASC and major depressive disorder (MDD.Significance differences in the global percentage of semi-metric edges was observed in both groups, with increases in ASC and decreases in MDD relative to controls. Furthermore, MDD was associated with regional differences in left frontal and temporal lobes, the right limbic system and cerebellum. In contrast, ASC had a broadly increased percentage of semi-metric edges with a more generalised distribution of effects and some areas of reduction. In summary, MDD was characterised by localised, large reductions in the percentage of semi-metric edges, whilst ASC is characterised by more generalised, subtle increases. These differences were corroborated in greater detail by inspection of the semi-metric backbone for each group; that is, the sub-graph of semi-metric edges present in >90% of participants, and by nodal degree differences in the semi-metric connectome.These encouraging results, in what we believe is the first application of semi-metric analysis to neuroimaging data, raise confidence in the methodology as potentially capable of detection and characterisation of a range of neurodevelopmental and psychiatric disorders.

  5. ESTIMATION OF HUMAN BODY SHAPE PARAMETERS USING MICROSOFT KINECTSENCOR

    Directory of Open Access Journals (Sweden)

    D. M. Vasilkov

    2017-01-01

    Full Text Available In the paper a human body shape estimation technology based on scan data acquired from sensor controller Microsoft Kinect is described. This device includes an RGB camera and a depth sensor that provides, for each pixel of the image,a distance from the camera focus to the object. A scan session produces a triangulated high-density surface noised with oscillations, isolated fragments and holes. When scanning a human, additional noise comes from garment folds and wrinkles. An algorithm of creating a sparse and regular 3D human body model (avatar free of these defects, which approximates shape, posture and basic metrics of the scanned body is proposed. This solution finds application in individual clothing industry and computer games, as well.

  6. Gender Recognition from Unconstrained and Articulated Human Body

    Directory of Open Access Journals (Sweden)

    Qin Wu

    2014-01-01

    human body images acquired from an unconstrained environment in the real world. A systematic study of some critical issues in body-based gender recognition, such as which body parts are informative, how many body parts are needed to combine together, and what representations are good for articulated body-based gender recognition, is also presented. This paper also pursues data fusion schemes and efficient feature dimensionality reduction based on the partial least squares estimation. Extensive experiments are performed on two unconstrained databases which have not been explored before for gender recognition.

  7. Coronary perfusion pressure and compression quality in maternal cardiopulmonary resuscitation in supine and left-lateral tilt positions: A prospective, crossover study using mannequins and swine models.

    Science.gov (United States)

    Dohi, Satoshi; Ichizuka, Kiyotake; Matsuoka, Ryu; Seo, Kohei; Nagatsuka, Masaaki; Sekizawa, Akihiko

    2017-09-01

    The risk of maternal and fetal mortality is high if cardiopulmonary arrest occurs during pregnancy. To assess the best position for maternal cardiopulmonary resuscitation (CPR), a prospective randomized crossover study was undertaken, involving basic life support mannequin-based simulation (BLS-MS) and a swine model of pulseless electrical activity (an unstable cardiac state) incorporating a fetal mannequin (PEA-FM). The BLS-MS (performed by certified rescuers) served to evaluate the quality of chest compressions in 30° left lateral tilt (LLT) and supine positions. Based on a 5-point scale, each rescuer subjectively graded their experience. The PEA-FM model was used to compare coronary perfusion pressure readings during CPR in supine, supine with left uterine displacement, 30° LLT, and 30° right lateral tilt positions. Compression rate and correctness of hand position, compression depth, and recoil were measures of compression quality (BLS-MS). Compared with LLT position, supine position enabled correct hand position (rate: 0.99 vs 0.88; p<0.05) and compression depth (rate: 0.76 vs 0.36; p<0.001) significantly more often. Moreover, BLS-MS rescuers found chest compressions significantly easier to perform with the mannequin in supine (vs LLT) position (difficulty score: 1.75 vs 3.95; p<0.001). In the PEA-FM study arm, supine position with left uterine displacement and right lateral tilt positions had the highest and lowest recorded coronary perfusion pressure readings, respectively. Supine position with left uterine displacement is optimal for maternal CPR. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  8. Measurement of hemothorax amount in patients with non-penetrating chest trauma by supine chest AP radiograph

    International Nuclear Information System (INIS)

    Han, Heon; Yang, Joo Hyun; Na, Myung Hoon; Baik, Hee Jong

    1994-01-01

    To evaluate the predictability of amount of hemothorax in the patients with blunt chest trauma, supine chest AP radiographs of 66 patients were reviewed and statistically analyzed. In 66 patients, rib fractures were present in 53 patients, hemothorax in 46 patients, pneumothorax in 25 patients, and pulmonary contusions in 18 patients. Width and length of hemothorax were measured on supine chest AP radiograph, and were correlated with known drained amount of hemothorax. The presence and number of rib fracture, pulmonary contusion, subcutaneous emphysema, fracture of scapula and clavicle, and total opacification of hemithorax were also correlated with the drained amount of hemothorax. In multiple logistic regression analysis, width of hemothorax had the highest correlation with drained amount of hemothorax(regression coeffcient 0.718, p value 0.00005). The presence and number of rib fracture, scapular fracture, subcutaneous emphysema were also correlated with drained amount of hemothorax. But length of hemothorax, pulmonary contusion, clavicular fracture, total opacification of hemithorax were not correlated with drained amount of hemothorax. Measured width of hemothorax in supine chest AP radiograph is the most reliable predictor for estimation of the amount of hemothorax, and may also be used as an indication for the application of closed thoracostomy in the treatment of hemothorax

  9. Measurement of hemothorax amount in patients with non-penetrating chest trauma by supine chest AP radiograph

    Energy Technology Data Exchange (ETDEWEB)

    Han, Heon; Yang, Joo Hyun; Na, Myung Hoon; Baik, Hee Jong [Chung-Ang Gil Hospital, Incheon (Korea, Republic of)

    1994-10-15

    To evaluate the predictability of amount of hemothorax in the patients with blunt chest trauma, supine chest AP radiographs of 66 patients were reviewed and statistically analyzed. In 66 patients, rib fractures were present in 53 patients, hemothorax in 46 patients, pneumothorax in 25 patients, and pulmonary contusions in 18 patients. Width and length of hemothorax were measured on supine chest AP radiograph, and were correlated with known drained amount of hemothorax. The presence and number of rib fracture, pulmonary contusion, subcutaneous emphysema, fracture of scapula and clavicle, and total opacification of hemithorax were also correlated with the drained amount of hemothorax. In multiple logistic regression analysis, width of hemothorax had the highest correlation with drained amount of hemothorax(regression coeffcient 0.718, p value 0.00005). The presence and number of rib fracture, scapular fracture, subcutaneous emphysema were also correlated with drained amount of hemothorax. But length of hemothorax, pulmonary contusion, clavicular fracture, total opacification of hemithorax were not correlated with drained amount of hemothorax. Measured width of hemothorax in supine chest AP radiograph is the most reliable predictor for estimation of the amount of hemothorax, and may also be used as an indication for the application of closed thoracostomy in the treatment of hemothorax.

  10. Exaggerated supine oblique view of the cervical spine

    International Nuclear Information System (INIS)

    Abel, M.S.

    1982-01-01

    The technique of the 60 degree supine oblique view is described together with anatomic skeletal studies of this projection. The view is convenient for emergency room radiography and useful in other clinical radiography. The view separates widely the anterior and posterior portions of the vertebrae in a side to side projection. This makes for an elongated but detailed view of the articular processes, pedicles, and intervertebral foramina. In the cadavar specimen and clinically the view is shown to be useful in delineating fracture deformities of the articular process and visualizing constriction of the intervertebral foramen superiorly. Encroachment of the foramen superiorly is likely to compromise the emerging nerve root in this area

  11. A semi-automatic method for developing an anthropomorphic numerical model of dielectric anatomy by MRI

    International Nuclear Information System (INIS)

    Mazzurana, M; Sandrini, L; Vaccari, A; Malacarne, C; Cristoforetti, L; Pontalti, R

    2003-01-01

    Complex permittivity values have a dominant role in the overall consideration of interaction between radiofrequency electromagnetic fields and living matter, and in related applications such as electromagnetic dosimetry. There are still some concerns about the accuracy of published data and about their variability due to the heterogeneous nature of biological tissues. The aim of this study is to provide an alternative semi-automatic method by which numerical dielectric human models for dosimetric studies can be obtained. Magnetic resonance imaging (MRI) tomography was used to acquire images. A new technique was employed to correct nonuniformities in the images and frequency-dependent transfer functions to correlate image intensity with complex permittivity were used. The proposed method provides frequency-dependent models in which permittivity and conductivity vary with continuity-even in the same tissue-reflecting the intrinsic realistic spatial dispersion of such parameters. The human model is tested with an FDTD (finite difference time domain) algorithm at different frequencies; the results of layer-averaged and whole-body-averaged SAR (specific absorption rate) are compared with published work, and reasonable agreement has been found. Due to the short time needed to obtain a whole body model, this semi-automatic method may be suitable for efficient study of various conditions that can determine large differences in the SAR distribution, such as body shape, posture, fat-to-muscle ratio, height and weight

  12. A novel human body exergy consumption formula to determine indoor thermal conditions for optimal human performance in office buildings

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Olesen, Bjarne W.

    2013-01-01

    In this paper, a novel human body exergy consumption formula was derived strictly according to Gagge's two-node thermal transfer model. The human body exergy consumption calculated by the formula was compared with values calculated using Shukuya's formula for a typical office environment....... The results show that human body exergy consumption calculated by either of these formulas reaches a minimum under the same thermal condition. It is shown that this is in accordance with expectation. The relation between human performance and human body exergy consumption was studied by analyzing the data...... obtained in simulated office environments in winter. The results show that human body exergy consumption and human performance are inversely as operative temperature changes from 17 to 28°C or human thermal sensation changes from −1.0 to +1.4, and that optimum thermal comfort cannot be expected to lead...

  13. The technique of craniospinal irradiation of paediatric patients in supine position

    International Nuclear Information System (INIS)

    Slampa, P.; Seneklova, Z.; Simicek, J.; Soumarova, R.; Burkon, P.; Burianova, L.

    2001-01-01

    Background. Postoperative radiation therapy has significant impact on local control and overall survival of paediatric patients with brain tumours but an irradiated volume is often a controversial issue. Our aim was to describe a new technique of craniospinal irradiation as a postoperative treatment in patients with the risk of relapse of brain tumours as well as to estimate the side effects of such craniospinal irradiation. Patients and methods. In the last 4 years, 17 paediatric patients under 15 years of age with medulloblastoma (8) ependymoma (6) and glioblastoma (3) received postoperative craniospinal axis radiotherapy by a new technique developed in our departments. This technique is based on irradiation in supine position with the use of asymmetric jaws of the linear accelerator. Results. Radiotherapy was well tolerated and dose-reduction was not needed in any case. Skin reactions were mild in all patients. The gastrointestinal and haematological toxicity was mild to moderate (WHO grade I-II). Conclusion. The proposed new technique of craniospinal irradiation is advantageous in terms of side effects and could be recommended to be widely used. Craniospinal irradiation in supine position is an alternative method to the treatment in prone position. The evaluation of the effectiveness was limited by a short follow-up interval. (author)

  14. Scandinavian Semantics and the Human Body

    DEFF Research Database (Denmark)

    Levisen, Carsten

    2015-01-01

    , it is demonstrated that Scandinavian and English systems differ significantly in some aspects of the way in which the construe the human body with words. The study ventures an innovative combination of methods, pairing the Natural Semantic Metalanguage (NSM) approach to linguistic and conceptual analysis......This paper presents an ethnolinguistic analysis of how the space between the head and the body is construed in Scandinavian semantic systems vis-a-vis the semantic system of English. With an extensive case study of neck-related meanings in Danish, and with cross-Scandinavian reference...... with empirical evidence from the Evolution of Semantic Systems (EoSS) project. This combination of empirical and interpretative tools helps to integrate evidence from semantics and semiotics, pinning out in great detail the intricacies of the meanings of particular body words. The paper concludes that body words...

  15. Sensing power transfer between the human body and the environment

    NARCIS (Netherlands)

    Veltink, Petrus H.; Kortier, H.G.; Schepers, H. Martin

    The power transferred between the human body and the environment at any time and the work performed are important quantities to be estimated when evaluating and optimizing the physical interaction between the human body and the environment in sports, physical labor, and rehabilitation. It is the

  16. Heat Exchange in “Human body - Thermal protection - Environment” System

    Science.gov (United States)

    Khromova, I. V.

    2017-11-01

    This article is devoted to the issues of simulation and calculation of thermal processes in the system called “Human body - Thermal protection - Environment” under low temperature conditions. It considers internal heat sources and convective heat transfer between calculated elements. Overall this is important for the Heat Transfer Theory. The article introduces complex heat transfer calculation method and local thermophysical parameters calculation method in the system called «Human body - Thermal protection - Environment», considering passive and active thermal protections, thermophysical and geometric properties of calculated elements in a wide range of environmental parameters (water, air). It also includes research on the influence that thermal resistance of modern materials, used in special protective clothes development, has on heat transfer in the system “Human body - Thermal protection - Environment”. Analysis of the obtained results allows adding of the computer research data to experiments and optimizing of individual life-support system elements, which are intended to protect human body from exposure to external factors.

  17. Scanning 3D full human bodies using Kinects.

    Science.gov (United States)

    Tong, Jing; Zhou, Jin; Liu, Ligang; Pan, Zhigeng; Yan, Hao

    2012-04-01

    Depth camera such as Microsoft Kinect, is much cheaper than conventional 3D scanning devices, and thus it can be acquired for everyday users easily. However, the depth data captured by Kinect over a certain distance is of extreme low quality. In this paper, we present a novel scanning system for capturing 3D full human body models by using multiple Kinects. To avoid the interference phenomena, we use two Kinects to capture the upper part and lower part of a human body respectively without overlapping region. A third Kinect is used to capture the middle part of the human body from the opposite direction. We propose a practical approach for registering the various body parts of different views under non-rigid deformation. First, a rough mesh template is constructed and used to deform successive frames pairwisely. Second, global alignment is performed to distribute errors in the deformation space, which can solve the loop closure problem efficiently. Misalignment caused by complex occlusion can also be handled reasonably by our global alignment algorithm. The experimental results have shown the efficiency and applicability of our system. Our system obtains impressive results in a few minutes with low price devices, thus is practically useful for generating personalized avatars for everyday users. Our system has been used for 3D human animation and virtual try on, and can further facilitate a range of home–oriented virtual reality (VR) applications.

  18. Investigation of human body potential measured by a non-contact measuring system.

    Science.gov (United States)

    Ichikawa, Norimitsu

    2016-12-07

    A human body is occasionally electrified in a room. This charged object will be a source of electrostatic accidents, including the malfunction of electronic equipment. Hence, prevention of these accidents is required. Accidents occasionally occur, even though antistatic clothes and shoes are used. One of the causes for these accidents is that there is a lack of the preventive measures. This situation occurs when using, for example, unconductive wax. In this study, human body potential (voltage) is measured using a non-contact measuring system. An investigation of the human body's voltage when using this system is conducted. The result demonstrates that the voltage of a human body wearing antistatic clothes and shoes or light clothes and slippers exceeds a malfunctioning voltage of a microelectronics device when the body walks on floors. Thus, accidents may occur even if a human body wearing the antistatic clothes walks on flooring. These results will be useful in estimating determination whether electrostatic accidents occur or not.

  19. Reliability of Heart Rate Variability in Children: Influence of Sex and Body Position During Data Collection.

    Science.gov (United States)

    Silva, Carla Cristiane; Bertollo, Maurizio; Reichert, Felipe Fossati; Boullosa, Daniel Alexandre; Nakamura, Fábio Yuzo

    2017-05-01

    To examine which body position and indices present better reliability of heart rate variability (HRV) measures in children and to compare the HRV analyzed in different body positions between sexes. Twenty eutrophic prepubertal children of each sex participated in the study. The RR intervals were recorded using a portable heart rate monitor twice a day for 7 min in the supine, sitting, and standing positions. The reproducibility was analyzed using the intraclass correlation coefficient (ICC; two way mixed) and within-subject coefficient of variation (CV).Two-way ANOVA with repeated measures was used to compare the sexes. High levels of reproducibility were indicated by higher ICC in the root-mean-square difference of successive normal RR intervals (RMSSD: 0.93 and 0.94) and Poincaré plot of the short-term RR interval variability (SD1: 0.92 and 0.94) parameters for boys and girls, respectively, in the supine position. The ICCs were lower in the sitting and standing positions for all HRV indices. In addition, the girls presented significantly higher values than the boys for SDNN and absolute high frequency (HF; p position. The supine position is the most reproducible for the HRV indices in both sexes, especially the vagal related indices.

  20. The evolution of body size and shape in the human career

    Science.gov (United States)

    Grabowski, Mark; Hatala, Kevin G.; Richmond, Brian G.

    2016-01-01

    Body size is a fundamental biological property of organisms, and documenting body size variation in hominin evolution is an important goal of palaeoanthropology. Estimating body mass appears deceptively simple but is laden with theoretical and pragmatic assumptions about best predictors and the most appropriate reference samples. Modern human training samples with known masses are arguably the ‘best’ for estimating size in early bipedal hominins such as the australopiths and all members of the genus Homo, but it is not clear if they are the most appropriate priors for reconstructing the size of the earliest putative hominins such as Orrorin and Ardipithecus. The trajectory of body size evolution in the early part of the human career is reviewed here and found to be complex and nonlinear. Australopith body size varies enormously across both space and time. The pre-erectus early Homo fossil record from Africa is poor and dominated by relatively small-bodied individuals, implying that the emergence of the genus Homo is probably not linked to an increase in body size or unprecedented increases in size variation. Body size differences alone cannot explain the observed variation in hominin body shape, especially when examined in the context of small fossil hominins and pygmy modern humans. This article is part of the themed issue ‘Major transitions in human evolution’. PMID:27298459

  1. Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions

    International Nuclear Information System (INIS)

    Kitamura, Kei; Shirato, Hiroki; Seppenwoolde, Yvette; Onimaru, Rikiya; Oda, Makoto; Fujita, Katsuhisa; Shimizu, Shinichi; Shinohara, Nobuo; Harabayashi, Toru; Miyasaka, Kazuo

    2002-01-01

    Purpose: To quantify three-dimensional (3D) movement of the prostate gland with the patient in the supine and prone positions and to analyze the movement frequency for each treatment position. Methods and Materials: The real-time tumor-tracking radiotherapy (RTRT) system was developed to identify the 3D position of a 2-mm gold marker implanted in the prostate 30 times/s using two sets of fluoroscopic images. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within the region of the planned coordinates relative to the isocenter. Ten patients with prostate cancer treated with RTRT were the subjects of this study. The coordinates of the gold marker were recorded every 0.033 s during RTRT in the supine treatment position for 2 min. The patient was then moved to the prone position, and the marker was tracked for 2 min to acquire data regarding movement in this position. Measurements were taken 5 times for each patient (once a week); a total of 50 sets for the 10 patients was analyzed. The raw data from the RTRT system were filtered to reduce system noise, and the amplitude of movement was then calculated. The discrete Fourier transform of the unfiltered data was performed for the frequency analysis of prostate movement. Results: No apparent difference in movement was found among individuals. The amplitude of 3D movement was 0.1-2.7 mm in the supine and 0.4-24 mm in the prone positions. The amplitude in the supine position was statistically smaller in all directions than that in the prone position (p < 0.0001). The amplitude in the craniocaudal and AP directions was larger than in the left-right direction in the prone position (p < 0.0001). No characteristic movement frequency was detected in the supine position. The respiratory frequency was detected for all patients regarding movement in the craniocaudal and AP directions in the prone position. The results of the frequency analysis suggest that prostate movement is

  2. [The solidarity of the human body].

    Science.gov (United States)

    Bioy, Xavier

    2014-06-01

    The legal and bioethical regulation of the uses of the elements of the human body can be described by means of the concept of solidarity. From the French example, we can so show that the State tries to frame solidarities which already exist, for example between people who share the same genome, in the family, or, on the contrary, tent to impose or to direct the sharing of the human biological resources (organs, tissues, gametes, stem cell...).

  3. Improvement in Obstructive Sleep Apnea With Weight Loss is Dependent on Body Position During Sleep.

    Science.gov (United States)

    Joosten, Simon A; Khoo, Jun K; Edwards, Bradley A; Landry, Shane A; Naughton, Matthew T; Dixon, John B; Hamilton, Garun S

    2017-05-01

    Weight loss fails to resolve obstructive sleep apnea (OSA) in most patients; however, it is unknown as to whether weight loss differentially affects OSA in the supine compared with nonsupine sleeping positions. We aimed to determine if weight loss in obese patients with OSA results in a greater reduction in the nonsupine apnea/hypopnea index (AHI) compared with the supine AHI, thus converting participants into supine-predominant OSA. Post hoc analysis of data from a randomized controlled trial assessing the effect of weight loss (bariatric surgery vs. medical weight loss) on OSA in 60 participants with obesity (body mass index: >35 and sleep study at 2 years. Eight of 37 (22%) patients demonstrated a normal nonsupine AHI (sleep avoidance may cure their OSA. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  4. Statistical multi-path exposure method for assessing the whole-body SAR in a heterogeneous human body model in a realistic environment.

    Science.gov (United States)

    Vermeeren, Günter; Joseph, Wout; Martens, Luc

    2013-04-01

    Assessing the whole-body absorption in a human in a realistic environment requires a statistical approach covering all possible exposure situations. This article describes the development of a statistical multi-path exposure method for heterogeneous realistic human body models. The method is applied for the 6-year-old Virtual Family boy (VFB) exposed to the GSM downlink at 950 MHz. It is shown that the whole-body SAR does not differ significantly over the different environments at an operating frequency of 950 MHz. Furthermore, the whole-body SAR in the VFB for multi-path exposure exceeds the whole-body SAR for worst-case single-incident plane wave exposure by 3.6%. Moreover, the ICNIRP reference levels are not conservative with the basic restrictions in 0.3% of the exposure samples for the VFB at the GSM downlink of 950 MHz. The homogeneous spheroid with the dielectric properties of the head suggested by the IEC underestimates the absorption compared to realistic human body models. Moreover, the variation in the whole-body SAR for realistic human body models is larger than for homogeneous spheroid models. This is mainly due to the heterogeneity of the tissues and the irregular shape of the realistic human body model compared to homogeneous spheroid human body models. Copyright © 2012 Wiley Periodicals, Inc.

  5. Variability in human body size

    Science.gov (United States)

    Annis, J. F.

    1978-01-01

    The range of variability found among homogeneous groups is described and illustrated. Those trends that show significantly marked differences between sexes and among a number of racial/ethnic groups are also presented. Causes of human-body size variability discussed include genetic endowment, aging, nutrition, protective garments, and occupation. The information is presented to aid design engineers of space flight hardware and equipment.

  6. Measurement of Radioactivity in the Human Body

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Nilsson, I

    1960-12-15

    A body counter with a steel room and a 4-inch-diameter by 4-inch thick Nal scintillation counter has been in operation since February 1958. It is used to control the internal contamination in people working with radioactive materials. Measurements have also been made on the natural activity in the human body. The average cesium-137/potassium ratio in a group of Swedish males was in May 1959 73 {mu}{mu}c per gram of body potassium and in June 1960 55 {mu}{mu}c per gram of body potassium. The cessation of the nuclear bomb tests has caused a decrease in the cesium level in people. This gives some information of how cesium is entering the biosphere.

  7. Measurement of Radioactivity in the Human Body

    International Nuclear Information System (INIS)

    Andersson, I.Oe.; Nilsson, I.

    1960-12-01

    A body counter with a steel room and a 4-inch-diameter by 4-inch thick Nal scintillation counter has been in operation since February 1958. It is used to control the internal contamination in people working with radioactive materials. Measurements have also been made on the natural activity in the human body. The average cesium-137/potassium ratio in a group of Swedish males was in May 1959 73 μμc per gram of body potassium and in June 1960 55 μμc per gram of body potassium. The cessation of the nuclear bomb tests has caused a decrease in the cesium level in people. This gives some information of how cesium is entering the biosphere

  8. Teaching exploration and practice of the human body structure course

    Institute of Scientific and Technical Information of China (English)

    Feng LI; Ming-feng CHEN; Wen-long DING

    2015-01-01

    In the 21 st century,the medical model has transformed from the biological model to the biopsycho-social medical model. The transformation of medical model raises higher requirements for the training of medical staff. Comprehensive promotion of the reform of medical education has become the consensus and trend,which breeds the integrated medical teaching that is based on modules and organ systems. As one of eight integrated modules,the human body structure course of Shanghai Jiao Tong University School of Medicine introduces morphological structures of normal human organs according to function systems( such as locomotor system,digestive system,angiological system,and nervous system) of human organs and parts of human body. This course endeavors to integrate theories with practices,contents of disciplines of basic medicine,and basic medicine with clinical medicine. The human body structure course combines basic medicine with clinical medicine and is an important part of medical science.

  9. Growth and relationship of live weight to body measurements in semi-domesticated reindeer (Rangifer tarandus tarandus L.

    Directory of Open Access Journals (Sweden)

    Mauri Nieminen

    1990-09-01

    Full Text Available Estimation of live weight from measurements of body dimensions is useful in many management activities with domestic animals. In present study live weight was measured from 2932 female and 1037 male semi-domesticated reindeer (Rangifer tarandus tarandus L. during different seasons in 1969-85. The age of reindeer varied between 1 day and 14 yrs. Back length (along back from second spinous process to base of tail and chest girth (just behind front legs were taken also from 1490 female and 510 male reindeer. The growth of reindeer from birth to adulthood was cumulative consisting of a rapid weight accretion during summers followed by a weight loss or stasis during winters. The mathematical analyses of the growth based on exponential solutions gave average values for growth of female and male reindeer. Body weight of females increased until the age of 4.5 yrs and that of males until the age of 5.5 yrs. During winter and spring body weight of hinds decreased 10 to 15 kg and that of stags 30 to 50 kg in different age groups. Significant linear regressions were found between live weight and back length (r = 0.809 and 0.892, live weight and chest girth (r = 0.860 and 0.872 and live weight and combined body measure (back length + chest girth (r = 0.877 and 0.941 and live weight and body volume (r = 0.905 and 0.954, respectively in female and male reindeer. Exponential regressions gave, however, the best estimations of live weight with combined body measure.

  10. Human body motion tracking based on quantum-inspired immune cloning algorithm

    Science.gov (United States)

    Han, Hong; Yue, Lichuan; Jiao, Licheng; Wu, Xing

    2009-10-01

    In a static monocular camera system, to gain a perfect 3D human body posture is a great challenge for Computer Vision technology now. This paper presented human postures recognition from video sequences using the Quantum-Inspired Immune Cloning Algorithm (QICA). The algorithm included three parts. Firstly, prior knowledge of human beings was used, the key joint points of human could be detected automatically from the human contours and skeletons which could be thinning from the contours; And due to the complexity of human movement, a forecasting mechanism of occlusion joint points was addressed to get optimum 2D key joint points of human body; And then pose estimation recovered by optimizing between the 2D projection of 3D human key joint points and 2D detection key joint points using QICA, which recovered the movement of human body perfectly, because this algorithm could acquire not only the global optimal solution, but the local optimal solution.

  11. Staying human in the 21st century : thinking beyond human enhancement technologies inside the body

    NARCIS (Netherlands)

    Est, van Q.C.; Schuijff, M.; Boer, de T.; Fischer, R.

    2013-01-01

    The debate on human enhancement has focused so far on invasive biomedical technologies that work inside the body. To fully address the question of what does it mean to be human in the 21st century, we should also pay attention to a broad range of technologies that work outside the body, but still

  12. A Dosimetric Comparison of Accelerated Partial Breast Irradiation Techniques: Multicatheter Interstitial Brachytherapy, Three-Dimensional Conformal Radiotherapy, and Supine Versus Prone Helical Tomotherapy

    International Nuclear Information System (INIS)

    Patel, Rakesh R.; Becker, Stewart J.; Das, Rupak K.; Mackie, Thomas R.

    2007-01-01

    Purpose: To compare dosimetrically four different techniques of accelerated partial breast irradiation (APBI) in the same patient. Methods and Materials: Thirteen post-lumpectomy interstitial brachytherapy (IB) patients underwent imaging with preimplant computed tomography (CT) in the prone and supine position. These CT scans were then used to generate three-dimensional conformal radiotherapy (3D-CRT) and prone and supine helical tomotherapy (PT and ST, respectively) APBI plans and compared with the treated IB plans. Dose-volume histogram analysis and the mean dose (NTD mean ) values were compared. Results: Planning target volume coverage was excellent for all methods. Statistical significance was considered to be a p value mean dose of 1.3 Gy 3 and 1.2 Gy 3 , respectively. Both of these methods were statistically significantly lower than the supine external beam techniques. Overall, all four methods yielded similar low doses to the heart. Conclusions: The use of IB and PT resulted in greater normal tissue sparing (especially ipsilateral breast and lung) than the use of supine external beam techniques of 3D-CRT or ST. However, the choice of APBI technique must be tailored to the patient's anatomy, lumpectomy cavity location, and overall treatment goals

  13. Subjective thermal sensation and human body exergy consumption rate: analysis and correlation

    DEFF Research Database (Denmark)

    Simone, Angela; Dovjak, M.; Kolarik, Jakub

    2011-01-01

    , it is reasonable to consider both the exergy flows in building and those within the human body. There is a need to verify the human-body exergy model with the Thermal-Sensation (TS) response of subjects exposed to different combinations of indoor climate parameters (temperature, humidity, etc.). First results...... available on the relation between human-body exergy consumption rates and subjectively assessed thermal sensation showed that the minimum human body exergy consumption rate is associated with thermal sensation votes close to thermal neutrality, tending to slightly cool side of thermal sensation. By applying...... the exergy concept to the built indoor environment, additional results are going to be explored. By using the data available so far of operative temperature (to), the human body exergy consumption rates increase as to increases above 24°C or decreases below 22°C at relative humidity (RH) lower than 50...

  14. Gender Recognition from Unconstrained and Articulated Human Body

    OpenAIRE

    Wu, Qin; Guo, Guodong

    2014-01-01

    Gender recognition has many useful applications, ranging from business intelligence to image search and social activity analysis. Traditional research on gender recognition focuses on face images in a constrained environment. This paper proposes a method for gender recognition in articulated human body images acquired from an unconstrained environment in the real world. A systematic study of some critical issues in body-based gender recognition, such as which body parts are informative, ho...

  15. Consideration of Shoulder Joint's Image with the Changed Tube Angle of the Shoulder Oblique Projection in Supine Position

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jae Hyun; Choi, Nam Gil [Dept. of Radiology, Chonnam National University Hospital, Kwangju (Korea, Republic of)

    2008-06-15

    There is a standard shoulder oblique method (Grashey method) available to view the shoulder joint. This method projects AP view of the shoulder joint so that the Humerus head's subuxation or joint degeneration can be easily visualized. However, in this view, the patients, with supine or sitting or erect position, have to keep their body obliquely. Whereas, the patients who are not well or operated, usually feel very uncomfortable to keep their body in this position and hence, we need other persons' help and much efforts will be needed to get the good quality shoulder joint view. Therefore, we thought of examining a method which shows the joint well by angling the tube to Medio-Lateral direction and without keeping the patients' one side upward in supine position. For this study, total 15 subjects with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 9 males and 6 females. Statistic group analysis was performed with ANOVA test. Scores of the evaluation of the experts were 1.01{+-}0.54 at 25 degrees, 2.50{+-}0.50 at 30 degrees, 2.85{+-}0.36 at 35 degrees and 2.33{+-}0.47 at 40 degrees, respectively, and they were significant(p<0.05, Table 1). Joint space of the Humerus head and Scapula were well distinguished at 35 degrees, 30 degrees and 40 degrees with the almost same score. However, the degree of distortion at 40 degrees was more severe than that at 30 degrees. Ultimately, 30-35 degrees views were shown to yield good quality shoulder oblique images. In conclusion, this method may be very useful for the patients who are uncomfortable and for the emergency patients. In order to get similar or comparable view, the same X-tube angle is recommended to be used before and after the operation. Therefore, we hope that this new angled method seems to be efficient.

  16. Transport of gaseous pollutants by convective boundary layer around a human body

    DEFF Research Database (Denmark)

    Licina, Dusan; Melikov, Arsen Krikor; Sekhar, Chandra

    2015-01-01

    This study investigates the ability of the human convective boundary layer to transport pollution in a quiescent indoor environment. The impact of the source location in the vicinity of a human body is examined in relation to pollution distribution in the breathing zone and the thickness...... of the pollution boundary layer. The study, in addition, evaluates the effects of the room air temperature, table positioning, and seated body inclination. The human body is represented by a thermal manikin that has a body shape, size, and surface temperature that resemble those of a real person. The results show...... at the upper back or behind the chair. The results also indicate that a decrease in personal exposure to pollutants released from or around the human body increases the extent to which the pollution spreads to the surroundings. Reducing the room air temperature or backward body inclination intensifies...

  17. Steady-state visually evoked potential correlates of human body perception.

    Science.gov (United States)

    Giabbiconi, Claire-Marie; Jurilj, Verena; Gruber, Thomas; Vocks, Silja

    2016-11-01

    In cognitive neuroscience, interest in the neuronal basis underlying the processing of human bodies is steadily increasing. Based on functional magnetic resonance imaging studies, it is assumed that the processing of pictures of human bodies is anchored in a network of specialized brain areas comprising the extrastriate and the fusiform body area (EBA, FBA). An alternative to examine the dynamics within these networks is electroencephalography, more specifically so-called steady-state visually evoked potentials (SSVEPs). In SSVEP tasks, a visual stimulus is presented repetitively at a predefined flickering rate and typically elicits a continuous oscillatory brain response at this frequency. This brain response is characterized by an excellent signal-to-noise ratio-a major advantage for source reconstructions. The main goal of present study was to demonstrate the feasibility of this method to study human body perception. To that end, we presented pictures of bodies and contrasted the resulting SSVEPs to two control conditions, i.e., non-objects and pictures of everyday objects (chairs). We found specific SSVEPs amplitude differences between bodies and both control conditions. Source reconstructions localized the SSVEP generators to a network of temporal, occipital and parietal areas. Interestingly, only body perception resulted in activity differences in middle temporal and lateral occipitotemporal areas, most likely reflecting the EBA/FBA.

  18. Protective effect of prone posture against hypergravity-induced arterial hypoxaemia in humans

    Science.gov (United States)

    Rohdin, M; Petersson, J; Mure, M; Glenny, R W; Lindahl, S G E; Linnarsson, D

    2003-01-01

    Patients with acute respiratory distress syndrome have increased lung tissue weight and therefore an increased hydrostatic pressure gradient down the lung. Also, they have a better arterial oxygenation in prone (face down) than in supine (face up) posture. We hypothesized that this effect of the direction of gravity also existed in healthy humans, when increased hydrostatic gradients were induced by hypergravity. Ten healthy subjects were studied in a human centrifuge while exposed to 1 or 5 G in anterio-posterior (supine) or posterio-anterior (prone) direction. We measured blood gases using remote-controlled sampling and gas exchange by mass spectrometry. Hypergravity led to marked impairments of arterial oxygenation in both postures and more so in supine posture. At 5 G, the arterial oxygen saturation was 84.6 ± 1.2 % (mean ±s.e.m.) in supine and 89.7 ± 1.4 % in prone posture (P postures. The alveolar-to-arterial PO2 difference increased at 5 G to 8.0 ± 0.2 kPa and 6.6 ± 0.3 kPa in supine and prone postures (P = 0.003). Arterial oxygenation was less impaired in prone during hypergravity due to a better-preserved alveolo-arterial oxygen transport. We speculate that mammals have developed a cardiopulmonary structure that favours function with the gravitational vector in the posterio-anterior direction. PMID:12598589

  19. Locatable-body temperature monitoring based on semi-active UHF RFID tags.

    Science.gov (United States)

    Liu, Guangwei; Mao, Luhong; Chen, Liying; Xie, Sheng

    2014-03-26

    This paper presents the use of radio-frequency identification (RFID) technology for the real-time remote monitoring of body temperature, while an associated program can determine the location of the body carrying the respective sensor. The RFID chip's internal integrated temperature sensor is used for both the human-body temperature detection and as a measurement device, while using radio-frequency communication to broadcast the temperature information. The adopted RFID location technology makes use of reference tags together with a nearest neighbor localization algorithm and a multiple-antenna time-division multiplexing location system. A graphical user interface (GUI) was developed for collecting temperature and location data for the data fusion by using RFID protocols. With a puppy as test object, temperature detection and localization experiments were carried out. The measured results show that the applied method, when using a mercury thermometer for comparison in terms of measuring the temperature of the dog, has a good consistency, with an average temperature error of 0.283 °C. When using the associated program over the area of 12.25 m2, the average location error is of 0.461 m, which verifies the feasibility of the sensor-carrier location by using the proposed program.

  20. Locatable-Body Temperature Monitoring Based on Semi-Active UHF RFID Tags

    Directory of Open Access Journals (Sweden)

    Guangwei Liu

    2014-03-01

    Full Text Available This paper presents the use of radio-frequency identification (RFID technology for the real-time remote monitoring of body temperature, while an associated program can determine the location of the body carrying the respective sensor. The RFID chip’s internal integrated temperature sensor is used for both the human-body temperature detection and as a measurement device, while using radio-frequency communication to broadcast the temperature information. The adopted RFID location technology makes use of reference tags together with a nearest neighbor localization algorithm and a multiple-antenna time-division multiplexing location system. A graphical user interface (GUI was developed for collecting temperature and location data for the data fusion by using RFID protocols. With a puppy as test object, temperature detection and localization experiments were carried out. The measured results show that the applied method, when using a mercury thermometer for comparison in terms of measuring the temperature of the dog, has a good consistency, with an average temperature error of 0.283 °C. When using the associated program over the area of 12.25 m2, the average location error is of 0.461 m, which verifies the feasibility of the sensor-carrier location by using the proposed program.

  1. Vertebral Fracture Assessment in Supine Position : Comparison by Using Conventional Semiquantitative Radiography and Visual Radiography

    NARCIS (Netherlands)

    Hospers, Ilone C.; van der Laan, Johan G.; Zeebregts, Clark J.; Nieboer, Patrick; Wolffenbuttel, Bruce H. R.; Dierckx, Rudi A.; Kreeftenberg, Herman G.; Jager, Pieter L.; Slart, Riemer H. J. A.

    Purpose: To retrospectively evaluate the accuracy of vertebral fracture assessment (VFA) performed with the patient in the supine position and conventional semiquantitative radiography of the spine by using conventional visual radiography of the spine as the reference standard. Materials and

  2. Optimization study of using PTC for human body heating dissipation

    Directory of Open Access Journals (Sweden)

    Tiberiu Adrian SALAORU

    2014-06-01

    Full Text Available A better knowledge of the human body heat loses mechanisms is important for both diminishing the number of deaths during the surgical procedures of the patients under effect of full anaesthesia and increasing the efficiency of the Heating, Ventilation and Air Conditioning (HVAC systems. For these studies it is necessary to manufacture a human body mannequin having its surface temperature maintained on a value close to the real human body temperature. A number of PTC (Positive Temperature Coefficient thermistors placed on the entire external surface of the mannequin can be used for this purpose. This paper presents a study of the transient heating regime and the stability of the maintained temperature, performed on these devices.

  3. Prior exercise speeds pulmonary oxygen uptake kinetics and increases critical power during supine but not upright cycling.

    Science.gov (United States)

    Goulding, Richie P; Roche, Denise M; Marwood, Simon

    2017-09-01

    What is the central question of this study? Critical power (CP) represents the highest work rate for which a metabolic steady state is attainable. The physiological determinants of CP are unclear, but research suggests that CP might be related to the time constant of phase II oxygen uptake kinetics (τV̇O2). What is the main finding and its importance? We provide the first evidence that τV̇O2 is mechanistically related to CP. A reduction of τV̇O2 in the supine position was observed alongside a concomitant increase in CP. This effect may be contingent on measures of oxygen availability derived from near-infrared spectroscopy. Critical power (CP) is a fundamental parameter defining high-intensity exercise tolerance and is related to the time constant of phase II pulmonary oxygen uptake kinetics (τV̇O2). To test the hypothesis that this relationship is causal, we determined the impact of prior exercise ('priming') on CP and τV̇O2 in the upright and supine positions. Seventeen healthy men were assigned to either upright or supine exercise groups, whereby CP, τV̇O2 and muscle deoxyhaemoglobin kinetics (τ [HHb] ) were determined via constant-power tests to exhaustion at four work rates with (primed) and without (control) priming exercise at ∼31%Δ. During supine exercise, priming reduced τV̇O2 (control 54 ± 18 s versus primed 39 ± 11 s; P exercise had no effect on τV̇O2 (control 37 ± 12 s versus primed 35 ± 8 s; P = 0.82), τ [HHb] (control 10 ± 5 s versus primed 14 ± 10 s; P = 0.10) or CP (control 235 ± 42 W versus primed 232 ± 35 W; P = 0.57) during upright exercise. The concomitant reduction of τV̇O2 and increased CP following priming in the supine group, effects that were absent in the upright group, provide the first experimental evidence that τV̇O2 is mechanistically related to critical power. The increased τ [HHb+Mb] suggests that this effect was mediated, at least in part, by improved oxygen

  4. A semi-spring and semi-edge combined contact model in CDEM and its application to analysis of Jiweishan landslide

    Directory of Open Access Journals (Sweden)

    Chun Feng

    2014-02-01

    Full Text Available Continuum-based discrete element method (CDEM is an explicit numerical method used for simulation of progressive failure of geological body. To improve the efficiency of contact detection and simplify the calculation steps for contact forces, semi-spring and semi-edge are introduced in calculation. Semi-spring is derived from block vertex, and formed by indenting the block vertex into each face (24 semi-springs for a hexahedral element. The formation process of semi-edge is the same as that of semi-spring (24 semi-edges for a hexahedral element. Based on the semi-springs and semi-edges, a new type of combined contact model is presented. According to this model, six contact types could be reduced to two, i.e. the semi-spring target face contact and semi-edge target edge contact. By the combined model, the contact force could be calculated directly (the information of contact type is not necessary, and the failure judgment could be executed in a straightforward way (each semi-spring and semi-edge own their characteristic areas. The algorithm has been successfully programmed in C++ program. Some simple numerical cases are presented to show the validity and accuracy of this model. Finally, the failure mode, sliding distance and critical friction angle of Jiweishan landslide are studied with the combined model.

  5. Emergency Handling for MAC Protocol in Human Body Communication

    Directory of Open Access Journals (Sweden)

    Kwon Youngmi

    2011-01-01

    Full Text Available The human body communication (HBC is a technology that enables short range data communication using the human body as a medium, like an electrical wire. Thus it removes the need for a traditional antenna. HBC may be used as a type of data communication in body area network (BAN, while the devices are being in contact with body. One of important issues in BAN is an emergency alarm because it may be closely related to human life. For emergency data communication, the most critical factor is the time constraint. IEEE 802.15.6 specifies that the emergency alarm for the BAN must be notified in less than 1 sec and must provide prioritization mechanisms for emergency traffic and notification. As one type of BAN, the HBC must follow this recommendation, too. Existing emergency handling methods in BAN are based on the carrier sensing capability on radio frequencies to detect the status of channels. However, PHY protocol in HBC does not provide the carrier sensing. So the previous methods are not well suitable for HBC directly. Additionally, in the environment that the emergency rate is very low, the allocation of dedicated slot(s for emergency in each superframe is very wasteful. In this work, we proposed specific emergency handling operation for human body communication's medium access control (HBC-MAC protocol to meet the emergency requirements for BAN. We also showed the optimal number of emergency slots for the various combinations of beacon intervals and emergency rates.

  6. Semi-automated preparation of the dopamine transporter ligand [18F]FECNT for human PET imaging studies

    International Nuclear Information System (INIS)

    Voll, Ronald J.; McConathy, Jonathan; Waldrep, Michael S.; Crowe, Ronald J.; Goodman, Mark M.

    2005-01-01

    The fluorine-18 labeled dopamine transport (DAT) ligand 2β-carbomethoxy-3β-(4-chlorophenyl)-8-(2-fluoroethyl)nortropane (FECNT) has shown promising properties as an in vivo DAT imaging agent in human and monkey PET studies. A semi-automated synthesis has been developed to reliably produce [ 18 F]FECNT in a 16% decay corrected yield. This method utilizes a new [ 18 F]fluoralkylating agent and provides high purity [ 18 F]FECNT in a formulation suitable for human use

  7. Convolutional Neural Networks for Human Activity Recognition Using Body-Worn Sensors

    Directory of Open Access Journals (Sweden)

    Fernando Moya Rueda

    2018-05-01

    Full Text Available Human activity recognition (HAR is a classification task for recognizing human movements. Methods of HAR are of great interest as they have become tools for measuring occurrences and durations of human actions, which are the basis of smart assistive technologies and manual processes analysis. Recently, deep neural networks have been deployed for HAR in the context of activities of daily living using multichannel time-series. These time-series are acquired from body-worn devices, which are composed of different types of sensors. The deep architectures process these measurements for finding basic and complex features in human corporal movements, and for classifying them into a set of human actions. As the devices are worn at different parts of the human body, we propose a novel deep neural network for HAR. This network handles sequence measurements from different body-worn devices separately. An evaluation of the architecture is performed on three datasets, the Oportunity, Pamap2, and an industrial dataset, outperforming the state-of-the-art. In addition, different network configurations will also be evaluated. We find that applying convolutions per sensor channel and per body-worn device improves the capabilities of convolutional neural network (CNNs.

  8. Hypoxia regulates microRNA expression in the human carotid body

    International Nuclear Information System (INIS)

    Mkrtchian, Souren; Lee, Kian Leong; Kåhlin, Jessica; Ebberyd, Anette; Poellinger, Lorenz; Fagerlund, Malin Jonsson; Eriksson, Lars I.

    2017-01-01

    The carotid body (CB) is the key sensing organ for physiological oxygen levels in the body. Under conditions of low oxygen (hypoxia), the CB plays crucial roles in signaling to the cardiorespiratory center in the medulla oblongata for the restoration of oxygen homeostasis. How hypoxia regulates gene expression in the human CB remains poorly understood. While limited information on transcriptional regulation in animal CBs is available, the identity and impact of important post-transcriptional regulators such as non-coding RNAs, and in particular miRNAs are not known. Here we show using ex vivo experiments that indeed a number of miRNAs are differentially regulated in surgically removed human CB slices when acute hypoxic conditions were applied. Analysis of the hypoxia-regulated miRNAs shows that they target biological pathways with upregulation of functions related to cell proliferation and immune response and downregulation of cell differentiation and cell death functions. Comparative analysis of the human CB miRNAome with the global miRNA expression patterns of a large number of different human tissues showed that the CB miRNAome had a unique profile which reflects its highly specialized functional status. Nevertheless, the human CB miRNAome is most closely related to the miRNA expression pattern of brain tissues indicating that they may have the most similar developmental origins. - Highlights: • Hypoxia triggers differential expression of many miRNAs in the human carotid body. • This can lead to the upregulation of proliferation and immune response functions. • CB expression profile in the carotid body resembles the miRNA expression pattern in the brain. • miRNAs are involved in the regulation of carotid body functions including oxygen sensing.

  9. Hypoxia regulates microRNA expression in the human carotid body

    Energy Technology Data Exchange (ETDEWEB)

    Mkrtchian, Souren, E-mail: souren.mkrtchian@ki.se [Section for Anesthesiology and Intensive Care Medicine, Department of Physiology and Pharmacology, Karolinska Institute, SE-171 77 Stockholm (Sweden); Lee, Kian Leong, E-mail: csilkl@nus.edu.sg [Cancer Science Institute of Singapore, National University of Singapore, 117599 Singapore (Singapore); Kåhlin, Jessica [Section for Anesthesiology and Intensive Care Medicine, Department of Physiology and Pharmacology, Karolinska Institute, SE-171 77 Stockholm (Sweden); Function Perioperative Medicine and Intensive Care, Karolinska University Hospital, SE-171 76 Stockholm (Sweden); Ebberyd, Anette [Section for Anesthesiology and Intensive Care Medicine, Department of Physiology and Pharmacology, Karolinska Institute, SE-171 77 Stockholm (Sweden); Poellinger, Lorenz [Cancer Science Institute of Singapore, National University of Singapore, 117599 Singapore (Singapore); Department of Cell and Molecular Biology, Karolinska Institute, SE-171 77 Stockholm (Sweden); Fagerlund, Malin Jonsson; Eriksson, Lars I. [Section for Anesthesiology and Intensive Care Medicine, Department of Physiology and Pharmacology, Karolinska Institute, SE-171 77 Stockholm (Sweden); Function Perioperative Medicine and Intensive Care, Karolinska University Hospital, SE-171 76 Stockholm (Sweden)

    2017-03-15

    The carotid body (CB) is the key sensing organ for physiological oxygen levels in the body. Under conditions of low oxygen (hypoxia), the CB plays crucial roles in signaling to the cardiorespiratory center in the medulla oblongata for the restoration of oxygen homeostasis. How hypoxia regulates gene expression in the human CB remains poorly understood. While limited information on transcriptional regulation in animal CBs is available, the identity and impact of important post-transcriptional regulators such as non-coding RNAs, and in particular miRNAs are not known. Here we show using ex vivo experiments that indeed a number of miRNAs are differentially regulated in surgically removed human CB slices when acute hypoxic conditions were applied. Analysis of the hypoxia-regulated miRNAs shows that they target biological pathways with upregulation of functions related to cell proliferation and immune response and downregulation of cell differentiation and cell death functions. Comparative analysis of the human CB miRNAome with the global miRNA expression patterns of a large number of different human tissues showed that the CB miRNAome had a unique profile which reflects its highly specialized functional status. Nevertheless, the human CB miRNAome is most closely related to the miRNA expression pattern of brain tissues indicating that they may have the most similar developmental origins. - Highlights: • Hypoxia triggers differential expression of many miRNAs in the human carotid body. • This can lead to the upregulation of proliferation and immune response functions. • CB expression profile in the carotid body resembles the miRNA expression pattern in the brain. • miRNAs are involved in the regulation of carotid body functions including oxygen sensing.

  10. Fast detection and modeling of human-body parts from monocular video

    NARCIS (Netherlands)

    Lao, W.; Han, Jungong; With, de P.H.N.; Perales, F.J.; Fisher, R.B.

    2009-01-01

    This paper presents a novel and fast scheme to detect different body parts in human motion. Using monocular video sequences, trajectory estimation and body modeling of moving humans are combined in a co-operating processing architecture. More specifically, for every individual person, features of

  11. Postural change from lateral to supine is an important mechanism enhancing cephalic spread after injection of intrathecal 0.5% plain bupivacaine for cesarean section.

    Science.gov (United States)

    Xu, F; Qian, M; Wei, Y; Wang, Y; Wang, J; Li, M; Zhang, Y; Zhao, Y; Guo, X

    2015-11-01

    Spinal anesthesia is widely used for cesarean section, but the factors that affect the spread of the block in pregnant patients are still not fully explained. This study was designed to investigate the effect of postural changes on sensory block level. Thirty patients scheduled for elective cesarean section under combined spinal-epidural anesthesia were randomly allocated into three groups. After intrathecal injection of 0.5% plain bupivacaine 7.5mg, patients in group S were immediately placed in the supine position with left tilt, patients in group L5 were kept lateral for 5 min and then turned to the supine position with left tilt, and patients in group L10 were kept lateral for 10 min and then turned to the supine position with left tilt. At 5 min, median cephalad level of sensory block was lower in groups L5 and L10 compared with group S (corrected Ppostural change from the lateral position to the supine position is an important mechanism enhancing cephalic spread of spinal anesthesia during late pregnancy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. DEVELOPMENT OF 2D HUMAN BODY MODELING USING THINNING ALGORITHM

    Directory of Open Access Journals (Sweden)

    K. Srinivasan

    2010-11-01

    Full Text Available Monitoring the behavior and activities of people in Video surveillance has gained more applications in Computer vision. This paper proposes a new approach to model the human body in 2D view for the activity analysis using Thinning algorithm. The first step of this work is Background subtraction which is achieved by the frame differencing algorithm. Thinning algorithm has been used to find the skeleton of the human body. After thinning, the thirteen feature points like terminating points, intersecting points, shoulder, elbow, and knee points have been extracted. Here, this research work attempts to represent the body model in three different ways such as Stick figure model, Patch model and Rectangle body model. The activities of humans have been analyzed with the help of 2D model for the pre-defined poses from the monocular video data. Finally, the time consumption and efficiency of our proposed algorithm have been evaluated.

  13. A finite-element simulation of galvanic coupling intra-body communication based on the whole human body.

    Science.gov (United States)

    Song, Yong; Zhang, Kai; Hao, Qun; Hu, Lanxin; Wang, Jingwen; Shang, Fuzhou

    2012-10-09

    Simulation based on the finite-element (FE) method plays an important role in the investigation of intra-body communication (IBC). In this paper, a finite-element model of the whole body model used for the IBC simulation is proposed and verified, while the FE simulation of the galvanic coupling IBC with different signal transmission paths has been achieved. Firstly, a novel finite-element method for modeling the whole human body is proposed, and a FE model of the whole human body used for IBC simulation was developed. Secondly, the simulations of the galvanic coupling IBC with the different signal transmission paths were implemented. Finally, the feasibility of the proposed method was verified by using in vivo measurements within the frequency range of 10 kHz-5 MHz, whereby some important conclusions were deduced. Our results indicate that the proposed method will offer significant advantages in the investigation of the galvanic coupling intra-body communication.

  14. Effects of MDMA on body temperature in humans

    Science.gov (United States)

    Liechti, Matthias E

    2014-01-01

    Hyperthermia is a severe complication associated with the recreational use of 3,4-methylenedioxymethamphetamine (MDMA, Ecstasy). In this review, the clinical laboratory studies that tested the effects of MDMA on body temperature are summarized. The mechanisms that underlie the hyperthermic effects of MDMA in humans and treatment of severe hyperthermia are presented. The data show that MDMA produces an acute and dose-dependent rise in core body temperature in healthy subjects. The increase in body temperature is in the range of 0.2-0.8°C and does not result in hyperpyrexia (>40°C) in a controlled laboratory setting. However, moderately hyperthermic body temperatures >38.0°C occur frequently at higher doses, even in the absence of physical activity and at room temperature. MDMA primarily releases serotonin and norepinephrine. Mechanistic clinical studies indicate that the MDMA-induced elevations in body temperature in humans partially depend on the MDMA-induced release of norepinephrine and involve enhanced metabolic heat generation and cutaneous vasoconstriction, resulting in impaired heat dissipation. The mediating role of serotonin is unclear. The management of sympathomimetic toxicity and associated hyperthermia mainly includes sedation with benzodiazepines and intravenous fluid replacement. Severe hyperthermia should primarily be treated with additional cooling and mechanical ventilation. PMID:27626046

  15. The construction of human body--from model to reality.

    Science.gov (United States)

    Motoc, A; Motoc, Marilena; Bolintineanu, S; Muşuroi, Corina; Munteanu, M

    2005-01-01

    The human body building represented a complex research topic for the scientist in the most diverse domains. Although their interests and reasons were different, the goal was always the same: establishing a relation to verify the ratio between the dimensions of the constituent segments It appears that the mystery was solved out in the XIX-th century by Adolf Zeising, a German, who, using the statistic calculus, defined the division of a segment by the gold section. This purely mathematic logic confirms the human body's integration in proportion to the finest segments, thus providing the technical instrument of building a fully harmonious human body. The present study aims to compare the ideal, the calculated perfection to the reality, namely the theoretically obtained values to the average values of an 18-year-old male. It appears that the differences refer especially to the limbs; both the superior ones and the inferior ones being longer comparing to the ideal pattern while the bust is shorter and broader.

  16. Air temperature investigation in microenvironment around a human body

    DEFF Research Database (Denmark)

    Licina, Dusan; Melikov, Arsen Krikor; Sekhar, Chandra

    2015-01-01

    The aim of this study is to investigate the temperature boundary layer around a human body in a quiescent indoor environment. The air temperature, mean in time and standard deviation of the temperature fluctuations around a breathing thermal manikin are examined in relation to the room temperature......, body posture and human respiratory flow. To determine to what extent the experiments represent the realistic scenario, the additional experiments were performed with a real human subject. The results show that at a lower room air temperature (20°C), the fluctuations of air temperature increased close...... to the surface of the body. The large standard deviation of air temperature fluctuations, up to 1.2°C, was recorded in the region of the chest, and up to 2.9°C when the exhalation was applied. The manikin leaned backwards increased the air temperature in the breathing zone, which was opposite from the forward...

  17. Wearable health monitoring using capacitive voltage-mode Human Body Communication.

    Science.gov (United States)

    Maity, Shovan; Das, Debayan; Sen, Shreyas

    2017-07-01

    Rapid miniaturization and cost reduction of computing, along with the availability of wearable and implantable physiological sensors have led to the growth of human Body Area Network (BAN) formed by a network of such sensors and computing devices. One promising application of such a network is wearable health monitoring where the collected data from the sensors would be transmitted and analyzed to assess the health of a person. Typically, the devices in a BAN are connected through wireless (WBAN), which suffers from energy inefficiency due to the high-energy consumption of wireless transmission. Human Body Communication (HBC) uses the relatively low loss human body as the communication medium to connect these devices, promising order(s) of magnitude better energy-efficiency and built-in security compared to WBAN. In this paper, we demonstrate a health monitoring device and system built using Commercial-Off-The-Shelf (COTS) sensors and components, that can collect data from physiological sensors and transmit it through a) intra-body HBC to another device (hub) worn on the body or b) upload health data through HBC-based human-machine interaction to an HBC capable machine. The system design constraints and signal transfer characteristics for the implemented HBC-based wearable health monitoring system are measured and analyzed, showing reliable connectivity with >8× power savings compared to Bluetooth low-energy (BTLE).

  18. Measuring Accurate Body Parameters of Dressed Humans with Large-Scale Motion Using a Kinect Sensor

    Directory of Open Access Journals (Sweden)

    Sidan Du

    2013-08-01

    Full Text Available Non-contact human body measurement plays an important role in surveillance, physical healthcare, on-line business and virtual fitting. Current methods for measuring the human body without physical contact usually cannot handle humans wearing clothes, which limits their applicability in public environments. In this paper, we propose an effective solution that can measure accurate parameters of the human body with large-scale motion from a Kinect sensor, assuming that the people are wearing clothes. Because motion can drive clothes attached to the human body loosely or tightly, we adopt a space-time analysis to mine the information across the posture variations. Using this information, we recover the human body, regardless of the effect of clothes, and measure the human body parameters accurately. Experimental results show that our system can perform more accurate parameter estimation on the human body than state-of-the-art methods.

  19. Persons and their bodies: how we should think about human embryos.

    Science.gov (United States)

    McLachlan, Hugh V

    2002-01-01

    The status of human embryos is discussed particularly in the light of the claim by Fox, in Health Care Analysis 8 that it would be useful to think of them in terms of cyborg metaphors. It is argued that we should consider human embryos for what they are--partially formed human bodies--rather than for what they are like in some respects (and unlike in others)--cyborgs. However to settle the issue of the status of the embryo is not to answer the moral questions which arise concerning how embryos should be treated. Since persons rather than bodies have rights, embryos do not have rights. However, whether or not embryos have rights, people can have duties concerning them. Furthermore, the persons whose fully developed bodies embryos will, might (or might have) become can have rights. Contrary to what is often assumed, it is not merely persons who have (or have had) living, developed human bodies who have moral rights: so it is argued in this paper.

  20. Signal transmission in a human body medium-based body sensor network using a Mach-Zehnder electro-optical sensor.

    Science.gov (United States)

    Song, Yong; Hao, Qun; Zhang, Kai; Wang, Jingwen; Jin, Xuefeng; Sun, He

    2012-11-30

    The signal transmission technology based on the human body medium offers significant advantages in Body Sensor Networks (BSNs) used for healthcare and the other related fields. In previous works we have proposed a novel signal transmission method based on the human body medium using a Mach-Zehnder electro-optical (EO) sensor. In this paper, we present a signal transmission system based on the proposed method, which consists of a transmitter, a Mach-Zehnder EO sensor and a corresponding receiving circuit. Meanwhile, in order to verify the frequency response properties and determine the suitable parameters of the developed system, in-vivo measurements have been implemented under conditions of different carrier frequencies, baseband frequencies and signal transmission paths. Results indicate that the proposed system will help to achieve reliable and high speed signal transmission of BSN based on the human body medium.

  1. Distortion-product otoacoustic emissions: body position effects with simultaneous presentation of tone pairs

    Directory of Open Access Journals (Sweden)

    Samuel R. Atcherson

    2011-11-01

    Full Text Available This study examined the effect of three different body positions on distortion-product otoacoustic emission (DPOAE amplitude and noise levels with multiple primary tone pairs simultaneously-presented to 36 normal-hearing female human adults. Other studies have demonstrated that the simultaneously presented tone pairs method shows clinical promise as a screener, but the sequential method remains in widespread clinical use. Postural changes have been suggested to have an effect not only on DPOAEs, but also transient-evoked OAEs and stimulus- frequency OAEs. DPOAE amplitude and noise levels were recorded in seated, supine, and side-lying positions to the following order of simultaneously-presented tone pairs relative to the f2 frequencies: 1187, 2375, and 4812 Hz; 1500, 3000, and 6062 Hz; and 1875, 3812, and 7625 Hz. No DPOAE could be detected reliably at 7625 Hz as result of poor signal-to-noise ratio. For remaining DPOAEs, statistical analyses revealed that amplitudes were not significantly different among the three body positions. However, at 1500 Hz and below, body position did have a statistically significant effect on noise levels though they are likely clinically negligible. Except at 7625 Hz, results suggest that DPOAEs recorded using a simultaneously presented tone pairs appear to be comparably recorded regardless of an individual’s body position.

  2. Rupture of the Distal Biceps Tendon Combined with a Supinator Muscle Tear in a 51-Year-Old Woman: A Case Report

    OpenAIRE

    Nayyar, Samir; Quirno, Martin; Hasan, Saqib; Rybak, Leon; Meislin, Robert J.

    2011-01-01

    Distal biceps tendon rupture is a relatively uncommon occurrence in the general female population, and to our knowledge, has not been reported in association with a supinator muscle tear. We report a case of 51-year-old woman who experienced sharp pain in her forearm and elbow after lifting a heavy object. History and physical examination raised suspicion for a distal biceps tendon rupture. MRI imaging determined a combined distal biceps tendon tear with a supinator muscle tear with subsequen...

  3. Arterial wave reflection decreases gradually from supine to upright

    DEFF Research Database (Denmark)

    van den Bogaard, Bas; Westerhof, Berend E; Best, Hendrik

    2011-01-01

    BACKGROUND. An increase in total peripheral resistance (TPR) usually increases arterial wave reflection. During passive head-up tilt (HUT), however, arterial wave reflection decreases with increasing TPR. This study addressed whether arterial wave reflection gradually decreases during HUT. METHODS....... In 10 healthy volunteers (22-39 years, nine males), we recorded finger arterial pressures in supine position (0°), and 30°and 70°degrees HUT and active standing (90°). Aortic pressure was constructed from the finger pressure signal and hemodynamics were calculated. Arterial wave reflection...... from 0.9 dyn s/cm(5) at 0? to 1.2, 1.4 and 1.4 dyn s/cm(5) at 30°, 70° and 90° (p wave reflection...

  4. Face-down positioning versus non-supine positioning in macular hole surgery

    DEFF Research Database (Denmark)

    Alberti, Mark; Dornonville de la Cour, Morten

    2015-01-01

    AIM: To evaluate the full thickness macular hole (FTMH) closure rate in patients positioning non-supine (NSP) compared with patients positioning face-down (FDP). METHODS: We retrospectively reviewed two FTMH case series-postoperative positioning was FDP and NSP, respectively. All eyes were...... group fully complied with the recommended positioning protocol. CONCLUSIONS: Results from consistent FTMH repair indicate similar anatomical success rates in FDP and NSP groups, suggesting that FDP is unnecessary. Objective monitoring of positioning would be beneficial in future FTMH studies to be able...

  5. Supine position and nonmodifiable risk factors for ventilator-associated pneumonia in trauma patients.

    Science.gov (United States)

    Michetti, Christopher P; Prentice, Heather A; Rodriguez, Jennifer; Newcomb, Anna

    2017-02-01

    We studied trauma-specific conditions precluding semiupright positioning and other nonmodifiable risk factors for their influence on ventilator-associated pneumonia (VAP). We performed a retrospective study at a Level I trauma center from 2008 to 2012 on ICU patients aged ≥15, who were intubated for more than 2 days. Using backward logistic regression, a composite of 4 factors (open abdomen, acute spinal cord injury, spine fracture, spine surgery) that preclude semiupright positioning (supine composite) and other variables were analyzed. In total, 77 of 374 (21%) patients had VAP. Abbreviated Injury Score head/neck greater than 2 (odds ratio [OR] 2.79, P = .006), esophageal obturator airway (OR 4.25, P = .015), red cell/plasma transfusion in the first 2 intensive care unit days (OR 2.59, P = .003), and 11 or more ventilator days (OR 17.38, P VAP risk factors, whereas supine composite, scene vs emergency department airway intervention, brain injury, and coma were not. Factors that may temporarily preclude semiupright positioning in intubated trauma patients were not associated with a higher risk for VAP. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Human cerebral venous outflow pathway depends on posture and central venous pressure

    DEFF Research Database (Denmark)

    Gisolf, J; van Lieshout, J J; van Heusden, K

    2004-01-01

    and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest......Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture...... and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position...

  7. Image to physical space registration of supine breast MRI for image guided breast surgery

    Science.gov (United States)

    Conley, Rebekah H.; Meszoely, Ingrid M.; Pheiffer, Thomas S.; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    Breast conservation therapy (BCT) is a desirable option for many women diagnosed with early stage breast cancer and involves a lumpectomy followed by radiotherapy. However, approximately 50% of eligible women will elect for mastectomy over BCT despite equal survival benefit (provided margins of excised tissue are cancer free) due to uncertainty in outcome with regards to complete excision of cancerous cells, risk of local recurrence, and cosmesis. Determining surgical margins intraoperatively is difficult and achieving negative margins is not as robust as it needs to be, resulting in high re-operation rates and often mastectomy. Magnetic resonance images (MRI) can provide detailed information about tumor margin extents, however diagnostic images are acquired in a fundamentally different patient presentation than that used in surgery. Therefore, the high quality diagnostic MRIs taken in the prone position with pendant breast are not optimal for use in surgical planning/guidance due to the drastic shape change between preoperative images and the common supine surgical position. This work proposes to investigate the value of supine MRI in an effort to localize tumors intraoperatively using image-guidance. Mock intraoperative setups (realistic patient positioning in non-sterile environment) and preoperative imaging data were collected from a patient scheduled for a lumpectomy. The mock intraoperative data included a tracked laser range scan of the patient's breast surface, tracked center points of MR visible fiducials on the patient's breast, and tracked B-mode ultrasound and strain images. The preoperative data included a supine MRI with visible fiducial markers. Fiducial markers localized in the MRI were rigidly registered to their mock intraoperative counterparts using an optically tracked stylus. The root mean square (RMS) fiducial registration error using the tracked markers was 3.4mm. Following registration, the average closest point distance between the MR

  8. Human body as a food for sexuality

    Directory of Open Access Journals (Sweden)

    Everton Luiz de Oliveira

    2017-06-01

    Full Text Available The present article depicts a theoretical walk, based on a historical and cultural narrative, that presents the body as a central element in the formatting and construction of human sexuality. Such walk intuits to show some projections, thoughts and materialization which ascertained the physical beauty as a promoter of desires, intentions and erotic feelings, in favor of an announced sexuality and common sense as ideal. The objective was also discuss, how the physical body aesthetic has been the driving force for configuring standard discourses on sexuality, distorting the idea that only the similar bodies to the hegemonic body models can be considered as object of desire, pleasure, and sexual and erotic practices. Finally, it learns that the body can also be admitted as an instrument to subvert the predetermined logic that body, beauty and sexual practices appear to form a triad in favor of the myth of perfect or performative sexuality. As the bodies (all of them has been recognized by the community as promoters of pleasures, desires and foundation for effective practices and sexual/erotic routines, regardless of their physiological, anatomical and aesthetic formatting.

  9. Comparison of Radiation Treatment Plans for Breast Cancer between 3D Conformal in Prone and Supine Positions in Contrast to VMAT and IMRT Supine Positions

    Science.gov (United States)

    Bejarano Buele, Ana Isabel

    The treatment regimen for breast cancer patients typically involves Whole Breast Irradiation (WBI). The coverage and extent of the radiation treatment is dictated by location of tumor mass, breast tissue distribution, involvement of lymph nodes, and other factors. The current standard treatment approach used at our institution is a 3D tangential beam geometry, which involves two fields irradiating the breast, or a four field beam arrangement covering the whole breast and involved nodes, while decreasing the dose to organs as risk (OARs) such as the lung and heart. The coverage of these targets can be difficult to achieve in patients with unfavorable thoracic geometries, especially in those cases in which the planning target volume (PTV) is extended to the chest wall. It is a well-known fact that exposure of the heart to ionizing radiation has been proved to increase the subsequent rate of ischemic heart disease. In these cases, inverse planned treatments have become a proven alternative to the 3D approach. The goal of this research project is to evaluate the factors that affect our current techniques as well as to adapt the development of inverse modulated techniques for our clinic, in which breast cancer patients are one of the largest populations treated. For this purpose, a dosimetric comparison along with the evaluation of immobilization devices was necessary. Radiation treatment plans were designed and dosimetrically compared for 5 patients in both, supine and prone positions. For 8 patients, VMAT and IMRT plans were created and evaluated in the supine position. Skin flash incorporation for inverse modulated plans required measurement of the surface dose as well as an evaluation of breast volume changes during a treatment course. It was found that prone 3D conformal plans as well as the VMAT and IMRT plans are generally superior in sparing OARs to supine plans with comparable PTV coverage. Prone setup leads to larger shifts in breast volume as well as in

  10. Determination of functional residual capacity with 133-xenon radiospirometry. Comparison with body plethysmography and helium spirometry. Effect of body position

    International Nuclear Information System (INIS)

    Kauppinen-Walin, K.; Sovijaervi, A.R.A.; Muittari, A.; Uusitalo, A.

    1980-01-01

    The accuracy of 133-xenon radiospirometry for determination of FRC in healthy subjects was studied. Forty volunteers, both smokers and non-smokers, were examined. The FRC of each subject was concurrently determined with radiospirometric, He-dilution in closed circuit, and body plethysmographic methods. The mean FRC measured by radiospirometry (FRCsub(RS)) was 0.72 1 larger than that measured by helium spirometry (FRCsub(He)) in sitting position (P<0.01). In supine position the FRCsub(RS) was 0.65 1 larger than the FRCsub(He) (P<0.01). The body plethysmography (sitting position) gave FRC (TGV) 0.35 1 larger than the FRCsub(He) sitting (P<0.01). The FRCsub(He) and the FRCsub(RS) in the sitting position were 0.48 and 0.55 1 larger than in the supine position (P<0.01), respectively. Trapped air correlated significantly (P<0.01) with the difference FRCsub(RS) - FRCsub(He), when sitting. The results indicated that the FRC determined radiospirometrically is significantly larger than the FRC determined with He-spirometry. The difference is systematic, suggesting that it is caused by 133-xenon dissolved in blood and accumulated in tissues of the thoracic cage and by dissimilar representation of trapped air in FRCsub(RS) and FRCsub(He). After correction for systematic error, the FRC obtained as a by-product of radiospirometry may be used. (author)

  11. Ultrasound and supine chest radiograph in road traffic accident patients: a reliable and convenient way to diagnose pleural effusion

    International Nuclear Information System (INIS)

    Mumtaz, U.; Zahur, Z.; Raza, M.A.

    2017-01-01

    Background: Portable bed side ultrasound and supine chest radiograph of 80 traumatic patients excluding very clinically unstable patients who subsequently underwent CT scan chest was done for traumatic effusion showing that ultrasound had a higher sensitivity than CXR, 88.23% and 77.94%, respectively, and a similar specificity of 100% and 100%, respectively. Objective of the study is to compare the diagnostic accuracy of high resolution ultrasound and supine chest x-ray in detection of pleural effusion in road traffic accident patients keeping plain CT chest as gold standard. Methods: This study was conducted in PIMS and PAEC General Hospital, Islamabad from 1st January to 15th December 2015. The current study examined total of 80 trauma (blunt and penetrating) patients coming to emergency departments of both hospitals specifically those who had road traffic accident history. Their portable bed side ultrasound and supine chest radiograph were performed for assessing pleural effusion and subsequently CT scan chest was done for confirmation as it's a gold standard. Results: Using CT findings as gold standard the sensitivity, specificity, positive predictive value and negative predictive value was assessed for both ultrasonography and chest radiography and found to be 88.23%,100%, 100%, 40% and 77.94%, 100%, 100%, 55.55% respectively with diagnostic accuracy of ultrasound 90% as compared to 81.25% for supine chest x-rays when compared with gold standard. Conclusion: Ultrasound and chest x-ray can be used as a useful and suitable adjunct to CT in road traffic accident patients as these are easily available, non-invasive, no contrast required, can be performed on bed side and carries no or little radiation risk. (author)

  12. More-Realistic Digital Modeling of a Human Body

    Science.gov (United States)

    Rogge, Renee

    2010-01-01

    A MATLAB computer program has been written to enable improved (relative to an older program) modeling of a human body for purposes of designing space suits and other hardware with which an astronaut must interact. The older program implements a kinematic model based on traditional anthropometric measurements that do provide important volume and surface information. The present program generates a three-dimensional (3D) whole-body model from 3D body-scan data. The program utilizes thin-plate spline theory to reposition the model without need for additional scans.

  13. Semi-automated scoring of triple-probe FISH in human sperm using confocal microscopy.

    Science.gov (United States)

    Branch, Francesca; Nguyen, GiaLinh; Porter, Nicholas; Young, Heather A; Martenies, Sheena E; McCray, Nathan; Deloid, Glen; Popratiloff, Anastas; Perry, Melissa J

    2017-09-01

    Structural and numerical sperm chromosomal aberrations result from abnormal meiosis and are directly linked to infertility. Any live births that arise from aneuploid conceptuses can result in syndromes such as Kleinfelter, Turners, XYY and Edwards. Multi-probe fluorescence in situ hybridization (FISH) is commonly used to study sperm aneuploidy, however manual FISH scoring in sperm samples is labor-intensive and introduces errors. Automated scoring methods are continuously evolving. One challenging aspect for optimizing automated sperm FISH scoring has been the overlap in excitation and emission of the fluorescent probes used to enumerate the chromosomes of interest. Our objective was to demonstrate the feasibility of combining confocal microscopy and spectral imaging with high-throughput methods for accurately measuring sperm aneuploidy. Our approach used confocal microscopy to analyze numerical chromosomal abnormalities in human sperm using enhanced slide preparation and rigorous semi-automated scoring methods. FISH for chromosomes X, Y, and 18 was conducted to determine sex chromosome disomy in sperm nuclei. Application of online spectral linear unmixing was used for effective separation of four fluorochromes while decreasing data acquisition time. Semi-automated image processing, segmentation, classification, and scoring were performed on 10 slides using custom image processing and analysis software and results were compared with manual methods. No significant differences in disomy frequencies were seen between the semi automated and manual methods. Samples treated with pepsin were observed to have reduced background autofluorescence and more uniform distribution of cells. These results demonstrate that semi-automated methods using spectral imaging on a confocal platform are a feasible approach for analyzing numerical chromosomal aberrations in sperm, and are comparable to manual methods. © 2017 International Society for Advancement of Cytometry. © 2017

  14. Intellectual property rights and detached human body parts.

    Science.gov (United States)

    Pila, Justine

    2014-01-01

    This paper responds to an invitation by the editors to consider whether the intellectual property (IP) regime suggests an appropriate model for protecting interests in detached human body parts. It begins by outlining the extent of existing IP protection for body parts in Europe, and the relevant strengths and weaknesses of the patent system in that regard. It then considers two further species of IP right of less obvious relevance. The first are the statutory rights of ownership conferred by domestic UK law in respect of employee inventions, and the second are the economic and moral rights recognised by European and international law in respect of authorial works. In the argument made, both of these species of IP right may suggest more appropriate models of sui generis protection for detached human body parts than patent rights because of their capacity better to accommodate the relevant public and private interests in respect of the same.

  15. Perspective of the Human Body in Sasang Constitutional Medicine

    Directory of Open Access Journals (Sweden)

    Junhee Lee

    2009-01-01

    Full Text Available The Sasang constitutional medicine (SCM, a medical tradition originating from Korea, is distinguished from the traditional Chinese medicine in its philosophical background, theoretical development and especially, the fundamental rationale that analyzes the structure and function of the human body within a quadrifocal scheme. In SCM, the structure of the body is comprehended within the Sasang quadrifocal scheme, and the function of the body is understood within the context of the energy-fluid metabolism and the water-food metabolism controlled by the four main organs (lung, spleen, liver and kidney. Also, the concept of Seong-Jeong is used to explain the structural and functional variations between different constitutional types that arise from the constitutional variations in organ system scheme, which are in turn caused by deviations in the constitutional Seong-Jeong. Therefore, understanding the SCM perspective of the human body is essential in order to fully appreciate the advantages of the constitutional typological system (which focuses on individual idiosyncrasies found in SCM.

  16. Resourcifying human bodies--Kant and bioethics.

    Science.gov (United States)

    Miyasaka, Michio

    2005-01-01

    This essay roughly sketches two major conceptions of autonomy in contemporary bioethics that promote the resourcification of human body parts: (1) a narrow conception of autonomy as self-determination; and (2) the conception of autonomy as dissociated from human dignity. In this paper I will argue that, on the one hand, these two conceptions are very different from that found in the modern European tradition of philosophical inquiry, because bioethics has concentrated on an external account of patient's self-determination and on dissociating dignity from internal human nature. However, on the other hand, they are consistent with more recent European philosophy. In this more recent tradition, human dignity has gradually been dissociated from contextual values, and human subjectivity has been dissociated from objectivity and absolutized as never to be objectified. In the concluding part, I will give a speculative sketch in which Kant's internal inquiry of maxim of ends, causality and end, and dignity as iirreplaceability is recombined with bioethics' externalized one and used to support an extended human resourcification.

  17. Body maps on the human genome.

    Science.gov (United States)

    Cherniak, Christopher; Rodriguez-Esteban, Raul

    2013-12-20

    Chromosomes have territories, or preferred locales, in the cell nucleus. When these sites are taken into account, some large-scale structure of the human genome emerges. The synoptic picture is that genes highly expressed in particular topologically compact tissues are not randomly distributed on the genome. Rather, such tissue-specific genes tend to map somatotopically onto the complete chromosome set. They seem to form a "genome homunculus": a multi-dimensional, genome-wide body representation extending across chromosome territories of the entire spermcell nucleus. The antero-posterior axis of the body significantly corresponds to the head-tail axis of the nucleus, and the dorso-ventral body axis to the central-peripheral nucleus axis. This large-scale genomic structure includes thousands of genes. One rationale for a homuncular genome structure would be to minimize connection costs in genetic networks. Somatotopic maps in cerebral cortex have been reported for over a century.

  18. A DXA Whole Body Composition Cross-Calibration Experience: Evaluation With Humans, Spine, and Whole Body Phantoms.

    Science.gov (United States)

    Krueger, Diane; Libber, Jessie; Sanfilippo, Jennifer; Yu, Hui Jing; Horvath, Blaine; Miller, Colin G; Binkley, Neil

    2016-01-01

    New densitometer installation requires cross-calibration for accurate longitudinal assessment. When replacing a unit with the same model, the International Society for Clinical Densitometry recommends cross-calibrating by scanning phantoms 10 times on each instrument and states that spine bone mineral density (BMD) should be within 1%, whereas total body lean, fat, and %fat mass should be within 2% of the prior instrument. However, there is limited validation that these recommendations provide adequate total body cross-calibration. Here, we report a total body cross-calibration experience with phantoms and humans. Cross-calibration between an existing and new Lunar iDXA was performed using 3 encapsulated spine phantoms (GE [GE Lunar, Madison, WI], BioClinica [BioClinica Inc, Princeton, NJ], and Hologic [Hologic Inc, Bedford, MA]), 1 total body composition phantom (BioClinica), and 30 human volunteers. Thirty scans of each phantom and a total body scan of human volunteers were obtained on each instrument. All spine phantom BMD means were similar (within 1%; g/cm2 bias) between the existing and new dual-energy X-ray absorptiometry unit. The BioClinica body composition phantom (BBCP) BMD and bone mineral content (BMC) values were within 2% with biases of 0.005 g/cm2 and -3.4 g. However, lean and fat mass and %fat differed by 4.6%-7.7% with biases of +463 g, -496 g, and -2.8%, respectively. In vivo comparison supported BBCP data; BMD and BMC were within ∼2%, but lean and fat mass and %fat differed from 1.6% to 4.9% with biases of +833 g, -860 g, and -1.1%. As all body composition comparisons exceeded the recommended 2%, the new densitometer was recalibrated. After recalibration, in vivo bias was lower (g, respectively. Similarly, BBCP lean and fat agreement improved. In conclusion, the BBCP behaves similarly, but not identical, to human in vivo measurements for densitometer cross-calibration. Spine phantoms, despite good BMD and BMC agreement, did not detect

  19. Half-life of each dioxin and PCB congener in the human body

    Energy Technology Data Exchange (ETDEWEB)

    Ogura, Isamura [National Institute of Advanced Industrial Science and Technology, Tsukuba (Japan)

    2004-09-15

    It is well known that dioxin and PCB congeners accumulate in the human body. For assessing their toxicological risk, it is important to know the half-life of each congener in the human body. This study summarizes the overall half-lives of congeners in humans as reported in the literature, and compares them with the half-lives due to fecal and sebum excretions, as estimated by data on the concentrations of congeners in feces and sebum in the literature. In addition, the overall half-lives of congeners for the general Japanese population were estimated from the data on dietary intakes and concentrations in the human body reported by the municipalities.

  20. Posture and movement in healthy preterm infants in supine position in and outside the nest

    NARCIS (Netherlands)

    Ferrari, F.; Bertoncelli, N.; Gallo, C.; Roversi, M. F.; Guerra, M. P.; Ranzi, A.; Madders-Algra, M.

    Objective: To evaluate whether lying in a nest affects the posture and spontaneous movements of healthy preterm infants. Method: 10 healthy preterm infants underwent serial video recording in the supine position, when lying in a nest and outside it, at three ages: 30-33 weeks postmenstrual age (PMA)

  1. Teaching practices epistemologically differentiated about human body learning

    Directory of Open Access Journals (Sweden)

    Rosália Maria Ribeiro de Aragão

    2011-12-01

    Full Text Available How could we teach about THE HUMAN BODY as a different way, in both epistemological and pedagogical approaches? How could we leave behind stagnant as well as stagnating aspects of traditional way of teaching, such as the fragmentation/segmentation of contents, the far away reality, the excessive use of details or else, whenever learning about our own body? These are some of the questions we have considered when trying to escape the bad influence which came from our "environment formation" - putting it on all the marks we have acquired inside or even outside school - trying to overview as meaning our body working...in constant interaction with the surrounding ambient. Among those pointed kind of formation marks we frequently acquire from studying at the University - which need to be transcended —here we come to detach those innumerable contacts with both anatomized and misfigurated supposed human bodies' which didn't even look like actual human bodies, because they could never seem to have sheltered life inside themselves. They were inert as well as static bodies, only used as a such of vain "didactic materials" that could/can permit many teachers on their educational formation to focus a certain teaching approach which only seeks both the students' memorization of an infinitude of "complicated words", and to structure the systems -by several procedures of nouns definition and/or classification - as part of the so called biological organism. In order to do a different way of teaching, we have based our approach on three alternative teaching methodologies which focus these matters under a constructive perspective. On those three focused studies, it is possible to observe that some very principles of a present day teaching approach were there considered to achieve some of them: the respect for the students' previous ideas; the understanding about knowledge as something that is not established for good but as ever changeable and, at last, the

  2. Human Activity Recognition from Body Sensor Data using Deep Learning.

    Science.gov (United States)

    Hassan, Mohammad Mehedi; Huda, Shamsul; Uddin, Md Zia; Almogren, Ahmad; Alrubaian, Majed

    2018-04-16

    In recent years, human activity recognition from body sensor data or wearable sensor data has become a considerable research attention from academia and health industry. This research can be useful for various e-health applications such as monitoring elderly and physical impaired people at Smart home to improve their rehabilitation processes. However, it is not easy to accurately and automatically recognize physical human activity through wearable sensors due to the complexity and variety of body activities. In this paper, we address the human activity recognition problem as a classification problem using wearable body sensor data. In particular, we propose to utilize a Deep Belief Network (DBN) model for successful human activity recognition. First, we extract the important initial features from the raw body sensor data. Then, a kernel principal component analysis (KPCA) and linear discriminant analysis (LDA) are performed to further process the features and make them more robust to be useful for fast activity recognition. Finally, the DBN is trained by these features. Various experiments were performed on a real-world wearable sensor dataset to verify the effectiveness of the deep learning algorithm. The results show that the proposed DBN outperformed other algorithms and achieves satisfactory activity recognition performance.

  3. Quasi-static modeling of human limb for intra-body communications with experiments.

    Science.gov (United States)

    Pun, Sio Hang; Gao, Yue Ming; Mak, PengUn; Vai, Mang I; Du, Min

    2011-11-01

    In recent years, the increasing number of wearable devices on human has been witnessed as a trend. These devices can serve for many purposes: personal entertainment, communication, emergency mission, health care supervision, delivery, etc. Sharing information among the devices scattered across the human body requires a body area network (BAN) and body sensor network (BSN). However, implementation of the BAN/BSN with the conventional wireless technologies cannot give optimal result. It is mainly because the high requirements of light weight, miniature, energy efficiency, security, and less electromagnetic interference greatly limit the resources available for the communication modules. The newly developed intra-body communication (IBC) can alleviate most of the mentioned problems. This technique, which employs the human body as a communication channel, could be an innovative networking method for sensors and devices on the human body. In order to encourage the research and development of the IBC, the authors are favorable to lay a better and more formal theoretical foundation on IBC. They propose a multilayer mathematical model using volume conductor theory for galvanic coupling IBC on a human limb with consideration on the inhomogeneous properties of human tissue. By introducing and checking with quasi-static approximation criteria, Maxwell's equations are decoupled and capacitance effect is included to the governing equation for further improvement. Finally, the accuracy and potential of the model are examined from both in vitro and in vivo experimental results.

  4. Exploring the human body space: A geographical information system based anatomical atlas

    Directory of Open Access Journals (Sweden)

    Antonio Barbeito

    2016-06-01

    Full Text Available Anatomical atlases allow mapping the anatomical structures of the human body. Early versions of these systems consisted of analogical representations with informative text and labeled images of the human body. With computer systems, digital versions emerged and the third and fourth dimensions were introduced. Consequently, these systems increased their efficiency, allowing more realistic visualizations with improved interactivity and functionality. The 4D atlases allow modeling changes over time on the structures represented. The anatomical atlases based on geographic information system (GIS environments allow the creation of platforms with a high degree of interactivity and new tools to explore and analyze the human body. In this study we expand the functions of a human body representation system by creating new vector data, topology, functions, and an improved user interface. The new prototype emulates a 3D GIS with a topological model of the human body, replicates the information provided by anatomical atlases, and provides a higher level of functionality and interactivity. At this stage, the developed system is intended to be used as an educational tool and integrates into the same interface the typical representations of surface and sectional atlases.

  5. Gender recognition from unconstrained and articulated human body.

    Science.gov (United States)

    Wu, Qin; Guo, Guodong

    2014-01-01

    Gender recognition has many useful applications, ranging from business intelligence to image search and social activity analysis. Traditional research on gender recognition focuses on face images in a constrained environment. This paper proposes a method for gender recognition in articulated human body images acquired from an unconstrained environment in the real world. A systematic study of some critical issues in body-based gender recognition, such as which body parts are informative, how many body parts are needed to combine together, and what representations are good for articulated body-based gender recognition, is also presented. This paper also pursues data fusion schemes and efficient feature dimensionality reduction based on the partial least squares estimation. Extensive experiments are performed on two unconstrained databases which have not been explored before for gender recognition.

  6. Gender Recognition from Unconstrained and Articulated Human Body

    Science.gov (United States)

    Wu, Qin; Guo, Guodong

    2014-01-01

    Gender recognition has many useful applications, ranging from business intelligence to image search and social activity analysis. Traditional research on gender recognition focuses on face images in a constrained environment. This paper proposes a method for gender recognition in articulated human body images acquired from an unconstrained environment in the real world. A systematic study of some critical issues in body-based gender recognition, such as which body parts are informative, how many body parts are needed to combine together, and what representations are good for articulated body-based gender recognition, is also presented. This paper also pursues data fusion schemes and efficient feature dimensionality reduction based on the partial least squares estimation. Extensive experiments are performed on two unconstrained databases which have not been explored before for gender recognition. PMID:24977203

  7. CAD Design of Human Male Body for Mass–Inertial Characteristics Studies

    Directory of Open Access Journals (Sweden)

    Nikolova Gergana

    2018-01-01

    Full Text Available The aim of the present research is to present a 16-segmental biomechanical model of the Bulgarian male to determine the mass-inertial characteristics of the body of the Bulgarian male based on parameters available in the literature and its 3D generation within SolidWorks software. The motivation of the research is to support mainly sport, rehabilitation, wearable robots and furniture design users. The proposed CAD model of the human body of men is verified against the analytical results from our previous investigation, as well as through comparison with data available in the provided references. In this paper we model two basic human body positions: standing position and sitting with thighs elevated. The comparison performed between our model results and data reported in literature gives us confidence that this model can be reliably used to calculate the mass-inertial characteristics of male body at any postures of the body that is of interest. Therefore, our model can be used to obtain data for positions which the human body has to take in everyday live, in sport, leisure, including space exploration, for investigating criminology cases – body fall, car crash, etc. The model is suitable for performing computer simulation in robotics, medicine, sport and other areas.

  8. Mathematical human body modelling for impact loading

    NARCIS (Netherlands)

    Happee, R.; Morsink, P.L.J.; Wismans, J.S.H.M.

    1999-01-01

    Mathematical modelling of the human body is widely used for automotive crash safety research and design. Simulations have contributed to a reduction of injury numbers by optimisation of vehicle structures and restraint systems. Currently such simulations are largely performed using occupant models

  9. Optimal Patient Positioning (Prone Versus Supine) for VMAT in Gynecologic Cancer: A Dosimetric Study on the Effect of Different Margins

    Energy Technology Data Exchange (ETDEWEB)

    Heijkoop, Sabrina T., E-mail: s.heijkoop@erasmusmc.nl [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Westerveld, Henrike; Bijker, Nina [Department of Radiation Oncology, Academic Medical Center, Amsterdam (Netherlands); Feije, Raphael; Sharfo, Abdul W. [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Wieringen, Niek van [Department of Radiation Oncology, Academic Medical Center, Amsterdam (Netherlands); Mens, Jan Willem M. [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands); Stalpers, Lukas J.A. [Department of Radiation Oncology, Academic Medical Center, Amsterdam (Netherlands); Hoogeman, Mischa S. [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam (Netherlands)

    2016-10-01

    Purpose/Objective: It is unknown whether the historically found dosimetric advantages of treating gynecologic cancer with the patient in a prone position with use of a small-bowel displacement device (belly-board) remain when volumetric arc therapy (VMAT) is used and whether these advantages depend on the necessary margin between clinical target volume (CTV) and planning target volume (PTV). The aim of this study is to determine the best patient position (prone or supine) in terms of sparing organs at risk (OAR) for various CTV-to-PTV margins and VMAT dose delivery. Methods and Materials: In an institutional review board—approved study, 26 patients with gynecologic cancer scheduled for primary (9) or postoperative (17) radiation therapy were scanned in a prone position on a belly-board and in a supine position on the same day. The primary tumor CTV, nodal CTV, bladder, bowel, and rectum were delineated on both scans. The PTVs were created each with a different margin for the primary tumor and nodal CTV. The VMAT plans were generated with our in-house system for automated treatment planning. For all margin combinations, the supine and prone plans were compared with consideration of all OAR dose-volume parameters but with highest priority given to bowel cavity V{sub 45Gy} (cm{sup 3}). Results: For both groups, the prone position reduced the bowel cavity V{sub 45Gy}, in particular for nodal margins ≥10 mm (ΔV{sub 45Gy} = 23.9 ± 10.6 cm{sup 3}). However, for smaller margins, the advantage was much less pronounced (ΔV{sub 45Gy} = 6.5 ± 3.0 cm{sup 3}) and did not reach statistical significance. The rectum mean dose (D{sub mean}) was significantly lower (ΔD{sub mean} = 2.5 ± 0.3 Gy) in the prone position for both patient groups and for all margins, and the bladder D{sub mean} was significantly lower in the supine position (ΔD{sub mean} = 2.6 ± 0.4 Gy) only for the postoperative group. The advantage of the prone position was not present if it

  10. Multi-modal RGB–Depth–Thermal Human Body Segmentation

    DEFF Research Database (Denmark)

    Palmero, Cristina; Clapés, Albert; Bahnsen, Chris

    2016-01-01

    This work addresses the problem of human body segmentation from multi-modal visual cues as a first stage of automatic human behavior analysis. We propose a novel RGB-Depth-Thermal dataset along with a multi-modal seg- mentation baseline. The several modalities are registered us- ing a calibration...... to other state-of-the-art meth- ods, obtaining an overlap above 75% on the novel dataset when compared to the manually annotated ground-truth of human segmentations....

  11. Transfer of radionuclides by terrestrial food products from semi-natural ecosystems to humans

    International Nuclear Information System (INIS)

    Howard, B.J.

    1996-01-01

    The potential radiological significance of radionuclide transfer to humans via foodstuffs derived from semi-natural ecosystems has become apparent since the Chernobyl accident. Foodchain models developed before this time usually did not take such transfers into account. The processes leading to contamination of food in these environments are complex and current understanding of the transfer mechanisms is incomplete. For these reasons the approach adopted in Chapter 3 is to represent, by means of aggregated parameters, the empirical relationships between ground deposits and concentration in the food product. 107 refs, 2 figs, 9 tabs

  12. Combined hyperextension and supination of the elbow joint induces lateral ligament lesions. An experimental study of the pathoanatomy and kinematics in elbow ligament injuries

    DEFF Research Database (Denmark)

    Tyrdal, Stein; Olsen, Bo Sanderhoff

    1998-01-01

    An epidemiological study suggested that the injury mechanism of 'handball goalie's elbow' may be hyperextension. The pathomechanics of hyperextension combined with supination was studied in ten macroscopically normal, male, cadaveric elbow joint specimens. The age of the donors was 28.8 years...... rupture of the lateral collateral ligament. The lesions indicate that combined hyperextension and supination represent a possible mechanism leading to 'handball goalie's elbow'....

  13. Modeling and characterization of different channels based on human body communication.

    Science.gov (United States)

    Jingzhen Li; Zedong Nie; Yuhang Liu; Lei Wang

    2017-07-01

    Human body communication (HBC), which uses the human body as a transmission medium for electrical signals, provides a prospective communication solution for body sensor networks (BSNs). In this paper, an inhomogeneous model which includes the tissue layers of skin, fat, and muscle is proposed to study the propagation characteristics of different HBC channels. Specifically, the HBC channels, namely, the on-body to on-body (OB-OB)channel, on-body to in-body (OB-IB) channel, in-body to on-body (IB-OB) channel, and in-body to in-body (IB-IB)channel, are studied over different frequencies (from 1MHz to 100MHz) through numerical simulations with finite-difference time-domain (FDTD) method. The results show that the gain of OB-IB channel and IB-OB channel is almost the same. The gain of IB-IB channel is greater than other channels in the frequency range 1MHz to 70MHz. In addition, the gain of all channels is associated with the channel length and communication frequency. The simulations are verified by experimental measurements in a porcine tissue sample. The results show that the simulations are in agreement with the measurements.

  14. Medidas espirométricas em pessoas eutróficas e obesas nas posições ortostática, sentada e deitada Spirometric values of obese and non-obese subjects on orthostatic, sitting and supine positions

    Directory of Open Access Journals (Sweden)

    Nilsa Cristina Domingos-Benício

    2004-04-01

    Full Text Available OBJETIVO: Alguns autores demonstraram que a obesidade gera restrição pulmonar, levando a uma redução dos volumes pulmonares. Entretanto, ainda existem controvérsias acerca da existência dessa restrição e do possível mecanismo responsável por essa alteração. Frente a isso, esse estudo teve como objetivo avaliar a influência do excesso de peso corporal na espirometria, em três diferentes posições corporais, avaliado pelo Índice de Massa Corpórea (IMC, percentual de gordura e relação cintura/quadril. MÉTODOS: Quarenta e seis universitários sedentários, com idades entre 20 e 40 anos, foram avaliados e distribuídos em cinco grupos, de acordo com o IMC. Os voluntários foram submetidos ao exame físico e à mensuração das pregas cutâneas e da circunferência da cintura e do quadril. CVF, VEF1 e VEF1/CVF foram avaliados em três diferentes posições - sentado, deitado e em pé. RESULTADOS: Quando comparados os valores obtidos e previstos entre os grupos, nenhuma diferença estatisticamente significante foi detectada. Quando comparadas as posições corporais, a posição deitada apresentou valores menores que as posições sentado e em pé (pBACKGROUND: It is possible that obesity could lead to pulmonary restriction with decreasing lung volumes. However, controversies about this restriction and its etiology still exist. Thus, the purpose of this report was to evaluate the effects of body weigh excess on spirometry, on three different body positions, evaluated by Body Mass Index (BMI, percentage of fatness and the ratio of abdominal girth to hip breadth (AG/HB. METHODS: Forty-six sedentary volunteers, with ages between 20 and 40 years, were studied and distributed on five groups, based on BMI. Skin fold thickness and ratio of abdominal girth to hip breadth (AG/HB of the volunteers were measured. FVC, FEV1 and ratio of FEV1 to FVC were measured on three different body positions - sitting, supine and orthostatic positions

  15. Investigation of the effects of human body stability on joint angles’ prediction

    International Nuclear Information System (INIS)

    Pasha Zanoosi, A. A.; Naderi, D.; Sadeghi-Mehr, M.; Feri, M.; Beheshtiha, A. Sh.; Fallahnejad, K.

    2015-01-01

    Loosing stability control in elderly or paralyzed has motivated researchers to study how a stability control system works and how to determine its state at every time instant. Studying the stability of a human body is not only an important problem from a scientific viewpoint, but also finally leads to new designs of prostheses and orthoses and rehabilitation methods. Computer modeling enables researchers to study and describe the reactions and propose a suitable and optimized motion pattern to strengthen the neuromuscular system and helps a human body maintain its stability. A perturbation as a tilting is exposed to an underfoot plate of a musculoskeletal model of the body to study the stability. The studied model of a human body included four links and three degrees of freedom with eight muscles in the sagittal plane. Lagrangian dynamics was used for deriving equations of motion and muscles were modeled using Hill’s model. Using experimental data of joint trajectories for a human body under tilting perturbation, forward dynamics has been applied to predict joint trajectories and muscle activation. This study investigated the effects of stability on predicting body joints’ motion. A new stability function for a human body, based on the zero moment point, has been employed in a forward dynamics procedure using a direct collocation method. A multi-objective optimization based on genetic algorithm has been proposed to employ stability as a robotic objective function along with muscle stresses as a biological objective function. The obtained results for joints’ motion were compared to experimental data. The results show that, for this type of perturbations, muscle stresses are in conflict with body stability. This means that more body stability requires more stresses in muscles and reverse. Results also show the effects of the stability objective function in better prediction of joint trajectories

  16. Investigation of the effects of human body stability on joint angles’ prediction

    Energy Technology Data Exchange (ETDEWEB)

    Pasha Zanoosi, A. A., E-mail: aliakbar.pasha@yahoo.com, E-mail: aliakbar.pasha@qiau.ac.ir [Islamic Azad University, Faculty of Industrial & Mechanical Engineering, Qazvin Branch (Iran, Islamic Republic of); Naderi, D.; Sadeghi-Mehr, M.; Feri, M. [Bu Ali-Sina University, Mechanical Engineering Department, Faculty of Engineering (Iran, Islamic Republic of); Beheshtiha, A. Sh. [Leibniz Universität Hannover, Institute of Mechanics and Computational Mechanics (Germany); Fallahnejad, K. [Flinders University, Discipline of Mechanical Engineering, School of Computer Science, Engineering and Mathematics (Australia)

    2015-10-15

    Loosing stability control in elderly or paralyzed has motivated researchers to study how a stability control system works and how to determine its state at every time instant. Studying the stability of a human body is not only an important problem from a scientific viewpoint, but also finally leads to new designs of prostheses and orthoses and rehabilitation methods. Computer modeling enables researchers to study and describe the reactions and propose a suitable and optimized motion pattern to strengthen the neuromuscular system and helps a human body maintain its stability. A perturbation as a tilting is exposed to an underfoot plate of a musculoskeletal model of the body to study the stability. The studied model of a human body included four links and three degrees of freedom with eight muscles in the sagittal plane. Lagrangian dynamics was used for deriving equations of motion and muscles were modeled using Hill’s model. Using experimental data of joint trajectories for a human body under tilting perturbation, forward dynamics has been applied to predict joint trajectories and muscle activation. This study investigated the effects of stability on predicting body joints’ motion. A new stability function for a human body, based on the zero moment point, has been employed in a forward dynamics procedure using a direct collocation method. A multi-objective optimization based on genetic algorithm has been proposed to employ stability as a robotic objective function along with muscle stresses as a biological objective function. The obtained results for joints’ motion were compared to experimental data. The results show that, for this type of perturbations, muscle stresses are in conflict with body stability. This means that more body stability requires more stresses in muscles and reverse. Results also show the effects of the stability objective function in better prediction of joint trajectories.

  17. Effect of postural changes on ICP in healthy and ill subjects

    DEFF Research Database (Denmark)

    Petersen, Lonnie G; Juhler, Marianne

    2015-01-01

    to distinguish normal human physiology from disease entities such as idiopathic intracranial hypertension and normal pressure hydrocephalus, we investigated ICP in different body postures in both normal and ill subjects. METHODS: Thirty-one patients were included: four normal patients following complete removal......: upright standing, sitting in a chair, supine and right lateral lumbar puncture position. RESULTS: Linear regression of median ICP based on patient posture, group, and purpose of monitoring presented a significant model (p ... of differences in median ICP between body postures and supine ICP as the baseline, presented a highly significant model (p posture (p postures enabled...

  18. Posture-specific phantoms representing female and male adults in Monte Carlo-based simulations for radiological protection

    Science.gov (United States)

    Cassola, V. F.; Kramer, R.; Brayner, C.; Khoury, H. J.

    2010-08-01

    Does the posture of a patient have an effect on the organ and tissue absorbed doses caused by x-ray examinations? This study aims to find the answer to this question, based on Monte Carlo (MC) simulations of commonly performed x-ray examinations using adult phantoms modelled to represent humans in standing as well as in the supine posture. The recently published FASH (female adult mesh) and MASH (male adult mesh) phantoms have the standing posture. In a first step, both phantoms were updated with respect to their anatomy: glandular tissue was separated from adipose tissue in the breasts, visceral fat was separated from subcutaneous fat, cartilage was segmented in ears, nose and around the thyroid, and the mass of the right lung is now 15% greater than the left lung. The updated versions are called FASH2_sta and MASH2_sta (sta = standing). Taking into account the gravitational effects on organ position and fat distribution, supine versions of the FASH2 and the MASH2 phantoms have been developed in this study and called FASH2_sup and MASH2_sup. MC simulations of external whole-body exposure to monoenergetic photons and partial-body exposure to x-rays have been made with the standing and supine FASH2 and MASH2 phantoms. For external whole-body exposure for AP and PA projection with photon energies above 30 keV, the effective dose did not change by more than 5% when the posture changed from standing to supine or vice versa. Apart from that, the supine posture is quite rare in occupational radiation protection from whole-body exposure. However, in the x-ray diagnosis supine posture is frequently used for patients submitted to examinations. Changes of organ absorbed doses up to 60% were found for simulations of chest and abdomen radiographs if the posture changed from standing to supine or vice versa. A further increase of differences between posture-specific organ and tissue absorbed doses with increasing whole-body mass is to be expected.

  19. Deciphering the iron isotope message of the human body

    Science.gov (United States)

    Walczyk, Thomas; von Blanckenburg, Friedhelm

    2005-04-01

    Mass-dependent variations in isotopic composition are known since decades for the light elements such as hydrogen, carbon or oxygen. Multicollector-inductively coupled plasma mass spectrometry (MC-ICP-MS) and double-spike thermal ionization mass spectrometry (TIMS) permit us now to resolve small variations in isotopic composition even for the heavier elements such as iron. Recent studies on the iron isotopic composition of human blood and dietary iron sources have shown that lighter iron isotopes are enriched along the food chain and that each individual bears a certain iron isotopic signature in blood. To make use of this finding in biomedical research, underlying mechanisms of isotope fractionation by the human body need to be understood. In this paper available iron isotope data for biological samples are discussed within the context of isotope fractionation concepts and fundamental aspects of human iron metabolism. This includes evaluation of new data for body tissues which show that blood and muscle tissue have a similar iron isotopic composition while heavier iron isotopes are concentrated in the liver. This new observation is in agreement with our earlier hypothesis of a preferential absorption of lighter iron isotopes by the human body. Possible mechanisms for inducing an iron isotope effect at the cellular and molecular level during iron uptake are presented and the potential of iron isotope effects in human blood as a long-term measure of dietary iron absorption is discussed.

  20. The major histocompatibility complex and perfumers' descriptions of human body odors

    OpenAIRE

    Wedekind, C.; Escher, S.; Van de Waal, M.; Frei, E.

    2007-01-01

    The MHC (major histocompatibility complex) is a group of genes that play a crucial role in immune recognition and in tolerance of tissue grafting. The MHC has also been found to influence body odors, body odor preferences, and mate choice in mice and humans. Here we test whether verbal descriptions of human body odors can be linked to the MHC. We asked 45 male students to live as odor neutral as possible for two consecutive days and to wear a T-shirt during the nights. The odors of these T-sh...

  1. Supine spinal magnetic resonance imaging with straightened lower extremities in spondylolisthesis: A comparison with the conventional technique

    International Nuclear Information System (INIS)

    Daghighi, Mohammad Hossein; Poureisa, Masoud; Arablou, Farid; Fouladi, Daniel F.

    2015-01-01

    Highlights: • MR imaging with straightened lower extremities was tested in spondylolisthesis. • This technique is more accurate than conventional MR imaging in detecting slip. • Level of spondylolisthesis is the only independent predictor of severity of slip. - Abstract: Objectives: To compare the degree of slip in spondylolisthesis on supine magnetic resonance (MR) images obtained with flexed and straightened lower extremities. Methods: Supine spinal MR studies were performed in 100 cases of symptomatic spondylolisthesis with flexed and then straightened lower extremities. The angle of lumbar lordosis (by Cobb's method) and the degree of slip (by Taillard's method) were compared between the two sets of images. Results: The mean angle of lumbar lordosis increased from 51.65 ± 8.57° on MR images with flexed lower limbs to 57.39 ± 9.05° on MR images with straightened lower limbs (p < 0.001; mean percent increase: 11.51%). Similar change was also observed for the mean degree of slip (from 25.80 ± 7.74% to 28.68 ± 7.93%, p < 0.001; mean percent increase: 12.60%). After MR imaging with straightened lower extremities 22 out of 54 initially grade I cases had grade II disease (p < 0.001). Conclusions: Supine magnetic resonance imaging with straightened lower extremities detects higher degree of slippage in symptomatic patients with spondylolisthesis compared to conventional MRI with flexed lower extremities

  2. Supine spinal magnetic resonance imaging with straightened lower extremities in spondylolisthesis: A comparison with the conventional technique

    Energy Technology Data Exchange (ETDEWEB)

    Daghighi, Mohammad Hossein; Poureisa, Masoud; Arablou, Farid [Department of Radiology, Imam Reza Teaching Center, Tabriz University of Medical Sciences, Tabriz (Iran, Islamic Republic of); Fouladi, Daniel F., E-mail: medicorelax@yahoo.com [Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz (Iran, Islamic Republic of)

    2015-05-15

    Highlights: • MR imaging with straightened lower extremities was tested in spondylolisthesis. • This technique is more accurate than conventional MR imaging in detecting slip. • Level of spondylolisthesis is the only independent predictor of severity of slip. - Abstract: Objectives: To compare the degree of slip in spondylolisthesis on supine magnetic resonance (MR) images obtained with flexed and straightened lower extremities. Methods: Supine spinal MR studies were performed in 100 cases of symptomatic spondylolisthesis with flexed and then straightened lower extremities. The angle of lumbar lordosis (by Cobb's method) and the degree of slip (by Taillard's method) were compared between the two sets of images. Results: The mean angle of lumbar lordosis increased from 51.65 ± 8.57° on MR images with flexed lower limbs to 57.39 ± 9.05° on MR images with straightened lower limbs (p < 0.001; mean percent increase: 11.51%). Similar change was also observed for the mean degree of slip (from 25.80 ± 7.74% to 28.68 ± 7.93%, p < 0.001; mean percent increase: 12.60%). After MR imaging with straightened lower extremities 22 out of 54 initially grade I cases had grade II disease (p < 0.001). Conclusions: Supine magnetic resonance imaging with straightened lower extremities detects higher degree of slippage in symptomatic patients with spondylolisthesis compared to conventional MRI with flexed lower extremities.

  3. The venality of human body parts and products in French law and common law.

    Science.gov (United States)

    Haoulia, Naima

    2012-03-01

    The successive bioethics laws in France have constantly argued that the human body is not for sale and consecrated an absolute principle of free and anonymous donations, whether of semen, ova, blood, tissues or organs. Nonetheless, this position is not shared by all countries. These legal divergences upset today our moral principles and the development of these practices leads us to question the legal status of human biological material and its gradual commodification. This paper outlines the current law principles that protect people's interests in their bodies, excised body parts and tissues without conferring the rights of full legal ownership in French law and in Common law. Contrary to what many people believe, people do not legally 'own' their bodies, body parts or tissues. However, they do have some legal rights in relation to their bodies and excised body material. For lawyers, the exact relationship people have with their bodies has raised a host of complex questions and long debates about the status we should grant to human body parts. The significance of this issue is due to two reasons:first, because of the imperative protection we have to assure to human dignity and then, because of the economic value which is attached to human products.

  4. PROBING THE ROLE OF DYNAMICAL FRICTION IN SHAPING THE BSS RADIAL DISTRIBUTION. I. SEMI-ANALYTICAL MODELS AND PRELIMINARY N-BODY SIMULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Miocchi, P.; Lanzoni, B.; Ferraro, F. R.; Dalessandro, E.; Alessandrini, E. [Dipartimento di Fisica e Astronomia, Università di Bologna, Viale Berti Pichat 6/2, I-40127 Bologna (Italy); Pasquato, M.; Lee, Y.-W. [Department of Astronomy and Center for Galaxy Evolution Research, Yonsei University, Seoul 120-749 (Korea, Republic of); Vesperini, E. [Department of Astronomy, Indiana University, Bloomington, IN 47405 (United States)

    2015-01-20

    We present semi-analytical models and simplified N-body simulations with 10{sup 4} particles aimed at probing the role of dynamical friction (DF) in determining the radial distribution of blue straggler stars (BSSs) in globular clusters. The semi-analytical models show that DF (which is the only evolutionary mechanism at work) is responsible for the formation of a bimodal distribution with a dip progressively moving toward the external regions of the cluster. However, these models fail to reproduce the formation of the long-lived central peak observed in all dynamically evolved clusters. The results of N-body simulations confirm the formation of a sharp central peak, which remains as a stable feature over time regardless of the initial concentration of the system. In spite of noisy behavior, a bimodal distribution forms in many cases, with the size of the dip increasing as a function of time. In the most advanced stages, the distribution becomes monotonic. These results are in agreement with the observations. Also, the shape of the peak and the location of the minimum (which, in most of cases, is within 10 core radii) turn out to be consistent with observational results. For a more detailed and close comparison with observations, including a proper calibration of the timescales of the dynamical processes driving the evolution of the BSS spatial distribution, more realistic simulations will be necessary.

  5. A relation between calculated human body exergy consumption rate and subjectively assessed thermal sensation

    DEFF Research Database (Denmark)

    Simone, Angela; Kolarik, Jakub; Iwamatsu, Toshiya

    2011-01-01

    occupants, it is reasonable to consider both the exergy flows in building and those within the human body. Until now, no data have been available on the relation between human-body exergy consumption rates and subjectively assessed thermal sensation. The objective of the present work was to relate thermal...... sensation data, from earlier thermal comfort studies, to calculated human-body exergy consumption rates. The results show that the minimum human body exergy consumption rate is associated with thermal sensation votes close to thermal neutrality, tending to the slightly cool side of thermal sensation....... Generally, the relationship between air temperature and the exergy consumption rate, as a first approximation, shows an increasing trend. Taking account of both convective and radiative heat exchange between the human body and the surrounding environment by using the calculated operative temperature, exergy...

  6. Estimation of temperature change in human body using MRI

    International Nuclear Information System (INIS)

    Nikawa, Yoshio; Nakamura, Suguru

    2016-01-01

    In the field of traditional oriental medicine, two types of treatment style, which are an acupuncture treatment and a moxibustion treatment have been performed. These treatments are used and effected by doctor or acupuncturist in their clinic or hospital and are widely spread. In spite of such a general treatment, it is not deeply discussed about mechanism of heat transfer modality and about temperature distribution in the treatment of moxibustion. Also, it is not discussed about temperature distribution deep inside human tissue during acupuncture treatment. It comes from the difficulty of noninvasive measurement of temperature deep inside human body. In this study, a temperature distribution for acupuncture and moxibustion treatment is measured and analyzed using thermograph and MRI by measuring the phase of longitudinal relaxation time of protons. The experimental results of measured temperature distribution under the human legs have been demonstrated. The result of temperature analysis in the human body is also reported. (author)

  7. Centralized Networks to Generate Human Body Motions.

    Science.gov (United States)

    Vakulenko, Sergei; Radulescu, Ovidiu; Morozov, Ivan; Weber, Andres

    2017-12-14

    We consider continuous-time recurrent neural networks as dynamical models for the simulation of human body motions. These networks consist of a few centers and many satellites connected to them. The centers evolve in time as periodical oscillators with different frequencies. The center states define the satellite neurons' states by a radial basis function (RBF) network. To simulate different motions, we adjust the parameters of the RBF networks. Our network includes a switching module that allows for turning from one motion to another. Simulations show that this model allows us to simulate complicated motions consisting of many different dynamical primitives. We also use the model for learning human body motion from markers' trajectories. We find that center frequencies can be learned from a small number of markers and can be transferred to other markers, such that our technique seems to be capable of correcting for missing information resulting from sparse control marker settings.

  8. Nuclear body formation and PML body remodeling by the human cytomegalovirus protein UL35

    International Nuclear Information System (INIS)

    Salsman, Jayme; Wang Xueqi; Frappier, Lori

    2011-01-01

    The human cytomegalovirus (HCMV) UL35 gene encodes two proteins, UL35 and UL35a. Expression of UL35 in transfected cells results in the formation of UL35 nuclear bodies that associate with promyelocytic leukemia (PML) protein. PML forms the basis for PML nuclear bodies that are important for suppressing viral lytic gene expression. Given the important relationship between PML and viral infection, we have further investigated the association of UL35 with PML bodies. We demonstrate that UL35 bodies form independently of PML and subsequently recruit PML, Sp100 and Daxx. In contrast, UL35a did not form bodies; however, it could bind UL35 and inhibit the formation of UL35 bodies. The HCMV tegument protein pp71 promoted the formation of UL35 bodies and the cytoplasmic localization of UL35a. Similarly, UL35a shifted pp71 to the cytoplasm. These results indicate that the interplay between UL35, UL35a and pp71 affects their subcellular localization and likely their functions throughout infection.

  9. [Usefulness of a protocol for carotid sinus massage in supine and erect postures in patients with syncope without other cardiovascular or neurological diseases].

    Science.gov (United States)

    Bocchiardo, M; Alciati, M; Buscemi, A; Cravetto, A; Richiardi, E; Gaita, F

    1995-05-01

    Carotid sinus massage is a first level test when investigating the cause of syncope. It is normally performed in the supine and erect positions. However, there is no standard complete protocol. So we have devised a new protocol to evaluate the utility of carotid sinus massage in different postures and the influence of patients age on the response. Two groups of subjects were selected: a group of 167 patients (mean age 50 ys +/- 18, 105 males, 62 females) with a history of syncope without cardiovascular and neurological disease and 20 asymptomatic control subjects (mean age 52 ys +/- 13, 11 males, 9 females). Carotid sinus massage was performed supine, just after passive tilt, after 5 minutes of tilt and just after passive return to supine. If a pause > 3" was detected, the protocol was repeated after atropine i.v. injection. Borderline vasodepressor: blood pressure reduction > 30 but blood pressure reduction > 50 mm Hg or > 30 mm Hg with symptoms like dizziness, vertigo or syncope; cardioinhibitory: pause > 3"; mixed: cardioinhibitory with blood pressure reduction > 30 mm Hg after atropine. Carotid sinus massage gave all informations in the supine position in 14 (12%) patients, after passive tilt in 67 (57%), after 5 minutes of tilt in 30 (26%), and after return to supine in 6 (5%). The responses were: 13 (8%) borderline vasodepressor, 32 (19%) vasodepressor, 2 (1%) cardioinhibitory, 70 (42%) mixed, 50 (30%) negative. Positive responses were more frequent in patients over 45 years (90% versus 43%). In the control group only 3 (15%) positive responses were elicited (2 borderline vasodepressor, and 1 vasodepressor, all in subjects over 45). This protocol for carotid sinus massage evidenced positive responses in 70% of patients with syncope without cardiovascular and neurological disease; cardioinhibitory responses are rare (2%); positive responses are more frequent in patients over 45 years; the protocol specificity was 85%.

  10. Body position and motor imagery strategy effects on imagining gait in healthy adults: Results from a cross-sectional study.

    Science.gov (United States)

    Beauchet, Olivier; Launay, Cyrille P; Sekhon, Harmehr; Gautier, Jennifer; Chabot, Julia; Levinoff, Elise J; Allali, Gilles

    2018-01-01

    Assessment of changes in higher levels of gait control with aging is important to better understand age-related gait instability, with the perspective to improve the screening of individuals at risk for falls. The comparison between actual Timed Up and Go test (aTUG) and its imagined version (iTUG) is a simple clinical way to assess age-related changes in gait control. The modulations of iTUG performances by body positions and motor imagery (MI) strategies with normal aging have not been evaluated yet. This study aims 1) to compare the aTUG time with the iTUG time under different body positions (i.e., sitting, standing or supine) in healthy young and middle age, and older adults, and 2) to examine the associations of body positions and MI strategies (i.e., egocentric versus allocentric) with the time needed to complete the iTUG and the delta TUG time (i.e., relative difference between aTUG and iTUG) while taking into consideration clinical characteristics of participants. A total of 60 healthy individuals (30 young and middle age participants 26.6±7.4 years, and 30 old participants 75.0±4.4 years) were recruited in this cross-sectional study. The iTUG was performed while sitting, standing and in supine position. Times of the aTUG, the iTUG under the three body positions, the TUG delta time and the strategies of MI (i.e., ego representation, defined as representation of the location of objects in space relative to the body axes of the self, versus allocentric representation defined as encoding information about body movement with respect to other object, the location of body being defined relative to the location of other objects) were used as outcomes. Age, sex, height, weight, number of drugs taken daily, level of physical activity and prevalence of closed eyes while performing iTUG were recorded. The aTUG time is significantly greater than iTUG while sitting and standing (Pposition. The multiple linear regressions confirm that the supine position is associated

  11. Review-Research on the physical training model of human body based on HQ.

    Science.gov (United States)

    Junjie, Liu

    2016-11-01

    Health quotient (HQ) is the newest health culture and concept in the 21st century, and the analysis of the human body sports model is not enough mature at present, what's more, the purpose of this paper is to study the integration of the two subjects the health quotient and the sport model. This paper draws the conclusion that physical training and education in colleges and universities can improve the health quotient, and it will make students possess a more healthy body and mind. Then through a new rigid body model of sports to simulate the human physical exercise. After that this paper has an in-depth study on the dynamic model of the human body movement on the basis of establishing the matrix and equation. The simulation results of the human body bicycle riding and pole throwing show that the human body joint movement simulation can be realized and it has a certain operability as well. By means of such simulated calculation, we can come to a conclusion that the movement of the ankle joint, knee joint and hip joint's motion law and real motion are basically the same. So it further verify the accuracy of the motion model, which lay the foundation of other research movement model, also, the study of the movement model is an important method in the study of human health in the future.

  12. Realistic Modeling and Animation of Human Body Based on Scanned Data

    Institute of Scientific and Technical Information of China (English)

    Yong-You Ma; Hui Zhang; Shou-Wei Jiang

    2004-01-01

    In this paper we propose a novel method for building animation model of real human body from surface scanned data.The human model is represented by a triangular mesh and described as a layered geometric model.The model consists of two layers: the control skeleton generating body animation from motion capture data,and the simplified surface model providing an efficient representation of the skin surface shape.The skeleton is generated automatically from surface scanned data using the feature extraction,and thena point-to-line mapping is used to map the surface model onto the underlying skeleton.The resulting model enables real-time and smooth animation by manipulation of the skeleton while maintaining the surface detail.Compared with earlier approach,the principal advantages of our approach are the automated generation of body control skeletons from the scanned data for real-time animation,and the automatic mapping and animation of the captured human surface shape.The human model constructed in this work can be used for applications of ergonomic design,garment CAD,real-time simulating humans in virtual reality environment and so on.

  13. A topological multilayer model of the human body.

    Science.gov (United States)

    Barbeito, Antonio; Painho, Marco; Cabral, Pedro; O'Neill, João

    2015-11-04

    Geographical information systems deal with spatial databases in which topological models are described with alphanumeric information. Its graphical interfaces implement the multilayer concept and provide powerful interaction tools. In this study, we apply these concepts to the human body creating a representation that would allow an interactive, precise, and detailed anatomical study. A vector surface component of the human body is built using a three-dimensional (3-D) reconstruction methodology. This multilayer concept is implemented by associating raster components with the corresponding vector surfaces, which include neighbourhood topology enabling spatial analysis. A root mean square error of 0.18 mm validated the three-dimensional reconstruction technique of internal anatomical structures. The expansion of the identification and the development of a neighbourhood analysis function are the new tools provided in this model.

  14. Transfer of fallout tritium from environment to human body

    International Nuclear Information System (INIS)

    Hisamatsu, Shun-ichi; Takizawa, Yukio

    1989-01-01

    A large quntity of tritium will be used as a fuel of nuclear fusion in the future. It is, therefore, considered important to elucidate tritium behavior present in the environment and the process of tritium transfer from the environment to the human body. Fallout tritium is an applicable material in searching for the long term behavior of tritium in the environment. This paper focuses on the American, Italian, Japanese literature concerning fallout tritium in food and in the human body. The specific activity ratio of bound to free tritium poses an important problem. The mechanism of biological concentration must await further studies. (N.K.) 63 refs

  15. Effect of the environmental stimuli upon the human body in winter outdoor thermal environment

    DEFF Research Database (Denmark)

    Sakoi, Tomonori; Kondo, Emi; Ishii, Jin

    2013-01-01

    the psychological thermal responses of the human body and winter outdoor thermal environment variables. Subjective experiments were conducted in the winter outdoor environment. Environmental factors and human psychological responses were measured. The relationship between the psychological thermal responses...... of the human body and the outdoor thermal environment index ETFe (enhanced conduction-corrected modified effective temperature) in winter was shown. The variables which influence the thermal sensation vote of the human body are air temperature, long-wave thermal radiation and short-wave solar radiation....... The variables that influence the thermal comfort vote of the human body are air temperature, humidity, short-wave solar radiation, long-wave thermal radiation, and heat conduction. Short-wave solar radiation, and heat conduction are among the winter outdoor thermal environment variables that affect...

  16. Medical Sequencing at the extremes of Human Body Mass

    Energy Technology Data Exchange (ETDEWEB)

    Ahituv, Nadav; Kavaslar, Nihan; Schackwitz, Wendy; Ustaszewski,Anna; Martin, Joes; Hebert, Sybil; Doelle, Heather; Ersoy, Baran; Kryukov, Gregory; Schmidt, Steffen; Yosef, Nir; Ruppin, Eytan; Sharan,Roded; Vaisse, Christian; Sunyaev, Shamil; Dent, Robert; Cohen, Jonathan; McPherson, Ruth; Pennacchio, Len A.

    2006-09-01

    Body weight is a quantitative trait with significantheritability in humans. To identify potential genetic contributors tothis phenotype, we resequenced the coding exons and splice junctions of58 genes in 379 obese and 378 lean individuals. Our 96Mb survey included21 genes associated with monogenic forms of obesity in humans or mice, aswell as 37 genes that function in body weight-related pathways. We foundthat the monogenic obesity-associated gene group was enriched for rarenonsynonymous variants unique to the obese (n=46) versus lean (n=26)populations. Computational analysis further predicted a significantlygreater fraction of deleterious variants within the obese cohort.Consistent with the complex inheritance of body weight, we did notobserve obvious familial segregation in the majority of the 28 availablekindreds. Taken together, these data suggest that multiple rare alleleswith variable penetrance contribute to obesity in the population andprovide a deep medical sequencing based approach to detectthem.

  17. Electromagnetic Modeling of Human Body Using High Performance Computing

    Science.gov (United States)

    Ng, Cho-Kuen; Beall, Mark; Ge, Lixin; Kim, Sanghoek; Klaas, Ottmar; Poon, Ada

    Realistic simulation of electromagnetic wave propagation in the actual human body can expedite the investigation of the phenomenon of harvesting implanted devices using wireless powering coupled from external sources. The parallel electromagnetics code suite ACE3P developed at SLAC National Accelerator Laboratory is based on the finite element method for high fidelity accelerator simulation, which can be enhanced to model electromagnetic wave propagation in the human body. Starting with a CAD model of a human phantom that is characterized by a number of tissues, a finite element mesh representing the complex geometries of the individual tissues is built for simulation. Employing an optimal power source with a specific pattern of field distribution, the propagation and focusing of electromagnetic waves in the phantom has been demonstrated. Substantial speedup of the simulation is achieved by using multiple compute cores on supercomputers.

  18. Influence of position and stimulation parameters on intracortical inhibition and facilitation in human tongue motor cortex

    DEFF Research Database (Denmark)

    Kothari, Mohit; Svensson, Peter; Nielsen, Jørgen Feldbæk

    Paired-pulse transcranial magnetic stimulation (ppTMS) can be used to assess short-interval intracortical inhibitory (SICI) and facilitatory (ICF) networks. The aim of the study was to examine the influence of body positions (recline and supine), inter-stimulus intervals (ISI) between the test...... recorded from contralateral tongue muscles. In study 1, single pulse and three ppTMS ISIs: 2, 10, 15 ms were applied 8 times each in three blocks (TS: 120%, 140% and 160% of resting motor threshold (rMT); CS: 80% of rMT) in two different body positions (recline and supine) randomly. In study 2, single...... pulse and four ppTMS ISIs: 2, 2.5, 3, 3.5 ms were applied 8 times each in randomized order in two blocks (CS: 70% and 80% of rMT; TS: 120% of rMT). There was a significant effect of body position (P=0.049), TS intensities (P

  19. The Effect of Body Mass on Outdoor Adult Human Decomposition.

    Science.gov (United States)

    Roberts, Lindsey G; Spencer, Jessica R; Dabbs, Gretchen R

    2017-09-01

    Forensic taphonomy explores factors impacting human decomposition. This study investigated the effect of body mass on the rate and pattern of adult human decomposition. Nine males and three females aged 49-95 years ranging in mass from 73 to 159 kg who were donated to the Complex for Forensic Anthropology Research between December 2012 and September 2015 were included in this study. Kelvin accumulated degree days (KADD) were used to assess the thermal energy required for subjects to reach several total body score (TBS) thresholds: early decomposition (TBS ≥6.0), TBS ≥12.5, advanced decomposition (TBS ≥19.0), TBS ≥23.0, and skeletonization (TBS ≥27.0). Results indicate no significant correlation between body mass and KADD at any TBS threshold. Body mass accounted for up to 24.0% of variation in decomposition rate depending on stage, and minor differences in decomposition pattern were observed. Body mass likely has a minimal impact on postmortem interval estimation. © 2017 American Academy of Forensic Sciences.

  20. Structure-cytotoxicity relationships of a series of natural and semi-synthetic simple coumarins as assessed in two human tumour cell lines

    NARCIS (Netherlands)

    Kolodziej, H; Kayser, O; Woerdenbag, HJ; vanUden, W; Pras, N

    1997-01-01

    The cytotoxicity of 22 natural and semi-synthetic simple coumarins was evaluated in GLC(4), a human small cell lung carcinoma cell line, and in COLO 320, a human colorectal cancer cell line, using the microculture tetrazolium (MTT) assay. With IC50 values > 100 mu M, following a continuous (96h)

  1. Visuals and Visualisation of Human Body Systems

    Science.gov (United States)

    Mathai, Sindhu; Ramadas, Jayashree

    2009-01-01

    This paper explores the role of diagrams and text in middle school students' understanding and visualisation of human body systems. We develop a common framework based on structure and function to assess students' responses across diagram and verbal modes. Visualisation is defined in terms of understanding transformations on structure and relating…

  2. The radioecological significance of semi-natural ecosystems

    International Nuclear Information System (INIS)

    Howard, B.J.; Howard, D.C.

    1997-01-01

    The transfer of radiocaesium to many food products either produced in or harvested from semi-natural ecosystems is high compared with intensive agricultural areas. Radiocaesium contamination levels in semi-natural foods are highly variable and difficult to predict. Spatial analysis may help to explain some of the variability and give improved estimates of the total output of radiocaesium in food products produced or harvested from semi-natural ecosystems. Consumption of foodstuffs from semi-natural ecosystems can contribute significantly to radiocaesium ingestion by humans. The long effective half-lives that occur for some semi-natural products lead to an increase with time in their importance compared with agricultural products. In determining the importance of semi-natural food products, the diet needs to be considered for both the average population and for special groups who utilize these environments to a greater extent than normal. Effective countermeasures have been developed to reduce radiocaesium levels in some semi-natural products. (author)

  3. The effect of low ambient temperature on the febrile responses of rats to semi-purified human endogenous pyrogen.

    Science.gov (United States)

    Stitt, J T; Shimada, S G

    1985-01-01

    The febrile responses of Sprague-Dawley rats to semi-purified human endogenous pyrogen were studied at a thermoneutral ambient temperature (26 degrees C) and in the cold (3 degrees C). It was found that while rats developed typical monophasic febrile responses at thermoneutrality, febrile responses were absent in the cold-exposed rats. Experiments were conducted to determine whether this lack of febrile responses in cold-exposed rats was due to an inability of these animals to generate or retain heat in the cold. Thermogenesis and vasoconstriction were stimulated in cold-exposed rats by selectively cooling the hypothalamus, using chronically implanted thermodes. It was shown that, using this stimulus, metabolic rate could be increased by more than 50 percent and body temperature could be driven up at a rate of 5 degrees C/hour in rats exposed to the cold. Therefore, it was concluded that the lack of febrile responses of cold-exposed rats to pyrogen is in no way due to a physical or physiological inability to retain heat. Instead, it appears that in some manner cold exposure suppresses the sensitivity or responsiveness of the rat to pyrogenic stimuli.

  4. SU-E-J-21: Setup Variability of Colorectal Cancer Patients Treated in the Prone Position and Dosimetric Comparison with the Supine Position

    Energy Technology Data Exchange (ETDEWEB)

    Kim, A; Foster, J; Chu, W; Karotki, A [Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, Ontario (Canada)

    2015-06-15

    Purpose: Many cancer centers treat colorectal patients in the prone position on a belly board to minimize dose to the small bowel. That may potentially Result in patient setup instability with corresponding impact on dose delivery accuracy for highly conformal techniques such as IMRT/VMAT. Two aims of this work are 1) to investigate setup accuracy of rectum patients treated in the prone position on a belly board using CBCT and 2) to evaluate dosimetric impact on bladder and small bowel of treating rectum patients in supine vs. prone position. Methods: For the setup accuracy study, 10 patients were selected. Weekly CBCTs were acquired and matched to bone. The CBCT-determined shifts were recorded. For the dosimetric study, 7 prone-setup patients and 7 supine-setup patients were randomly selected from our clinical database. Various clinically relevant dose volume histogram values were recorded for the small bowel and bladder. Results: The CBCT-determined rotational shifts had a wide variation. For the dataset acquired at the time of this writing, the ranges of rotational setup errors for pitch, roll, and yaw were [−3.6° 4.7°], [−4.3° 3.2°], and [−1.4° 1.4°]. For the dosimetric study: the small bowel V(45Gy) and mean dose for the prone position was 5.6±12.1% and 18.4±6.2Gy (ranges indicate standard deviations); for the supine position the corresponding dose values were 12.9±15.8% and 24.7±8.8Gy. For the bladder, the V(30Gy) and mean dose for prone position were 68.7±12.7% and 38.4±3.3Gy; for supine position these dose values were 77.1±13.7% and 40.7±3.1Gy. Conclusion: There is evidence of significant rotational instability in the prone position. The OAR dosimetry study indicates that there are some patients that may still benefit from the prone position, though many patients can be safely treated supine.

  5. A new approach to the semi-classical relativistic two-body problem for charged fermions

    International Nuclear Information System (INIS)

    Leiter, D.

    1978-01-01

    Generalizing from a recently developed hybrid formulation of classical electrodynamics with ''direct (charge-field) action'' structure an analogous semi-classical Dirac formulation of the theory is constructed, which is capable of describing the semi-classical quantum mechanics of two identical spin-1/2 particles. This semi-classical formulation is to be used as a heuristic aid in searching for the theoretical structure of a fully ''second quantized'' theory. The Pauli exclusion principle is incorporated by making the interaction fields (in the action principle) antisymmetric with respect to ''charge-field'' labeling. In this manner, ''position correlation'' effects associated with ''configuration interaction'' can also be accounted for. By studying the nature of the stationary-state solutions, the formalism is compared with the conventional quantum-mechanical one (to understand the similarities and the differences between this approach and the usual correlated Hartree-Fock approximation of ordinary relativistic quantum theory). The stationary-state solutions to the semi-classical formalism are shown to closely approximate the usual quantum-mechanical solutions when the wave functions are represented as a superposition of Slater determinants of Dirac-Coulombic-type wave functions with radial parts having a form which extremizes the total Breit energy. The manner in which this semi-classical theory might be extended to a fully ''second quantized'' formalism is sketched. (author)

  6. Inverse correlation between the standard deviation of R-R intervals in supine position and the simplified menopausal index in women with climacteric symptoms.

    Science.gov (United States)

    Yanagihara, Nobuyuki; Seki, Meikan; Nakano, Masahiro; Hachisuga, Toru; Goto, Yukio

    2014-06-01

    Disturbance of autonomic nervous activity has been thought to play a role in the climacteric symptoms of postmenopausal women. This study was therefore designed to investigate the relationship between autonomic nervous activity and climacteric symptoms in postmenopausal Japanese women. The autonomic nervous activity of 40 Japanese women with climacteric symptoms and 40 Japanese women without climacteric symptoms was measured by power spectral analysis of heart rate variability using a standard hexagonal radar chart. The scores for climacteric symptoms were determined using the simplified menopausal index. Sympathetic excitability and irritability, as well as the standard deviation of mean R-R intervals in supine position, were significantly (P standard deviation of mean R-R intervals in supine position and the simplified menopausal index score. The lack of control for potential confounding variables was a limitation of this study. In climacteric women, the standard deviation of mean R-R intervals in supine position is negatively correlated with the simplified menopausal index score.

  7. Point-Structured Human Body Modeling Based on 3D Scan Data

    Directory of Open Access Journals (Sweden)

    Ming-June Tsai

    2018-01-01

    Full Text Available A novel point-structured geometrical modelling for realistic human body is introduced in this paper. This technique is based on the feature extraction from the 3D body scan data. Anatomic feature such as the neck, the arm pits, the crotch points, and other major feature points are recognized. The body data is then segmented into 6 major parts. A body model is then constructed by re-sampling the scanned data to create a point-structured mesh. The body model contains body geodetic landmarks in latitudinal and longitudinal curves passing through those feature points. The body model preserves the perfect body shape and all the body dimensions but requires little space. Therefore, the body model can be used as a mannequin in garment industry, or as a manikin in various human factor designs, but the most important application is to use as a virtue character to animate the body motion in mocap (motion capture systems. By adding suitable joint freedoms between the segmented body links, kinematic and dynamic properties of the motion theories can be applied to the body model. As a result, a 3D virtual character that is fully resembled the original scanned individual is vividly animating the body motions. The gaps between the body segments due to motion can be filled up by skin blending technique using the characteristic of the point-structured model. The model has the potential to serve as a standardized datatype to archive body information for all custom-made products.

  8. Earthing the human body influences physiologic processes.

    Science.gov (United States)

    Sokal, Karol; Sokal, Pawel

    2011-04-01

    This study was designed to answer the question: Does the contact of the human organism with the Earth via a copper conductor affect physiologic processes? Subjects and experiments: Five (5) experiments are presented: experiment 1-effect of earthing on calcium-phosphate homeostasis and serum concentrations of iron (N = 84 participants); experiment 2-effect of earthing on serum concentrations of electrolytes (N = 28); experiment 3-effect of earthing on thyroid function (N = 12); experiment 4-effect of earthing on glucose concentration (N = 12); experiment 5-effect of earthing on immune response to vaccine (N = 32). Subjects were divided into two groups. One (1) group of people was earthed, while the second group remained without contact with the Earth. Blood and urine samples were examined. Earthing of an electrically insulated human organism during night rest causes lowering of serum concentrations of iron, ionized calcium, inorganic phosphorus, and reduction of renal excretion of calcium and phosphorus. Earthing during night rest decreases free tri-iodothyronine and increases free thyroxine and thyroid-stimulating hormone. The continuous earthing of the human body decreases blood glucose in patients with diabetes. Earthing decreases sodium, potassium, magnesium, iron, total protein, and albumin concentrations while the levels of transferrin, ferritin, and globulins α1, α2, β, and γ increase. These results are statistically significant. Earthing the human body influences human physiologic processes. This influence is observed during night relaxation and during physical activity. Effect of the earthing on calcium-phosphate homeostasis is the opposite of that which occurs in states of weightlessness. It also increases the activity of catabolic processes. It may be the primary factor regulating endocrine and nervous systems.

  9. A randomized clinical trial to compare the immediate effects of seated thoracic manipulation and targeted supine thoracic manipulation on cervical spine flexion range of motion and pain.

    Science.gov (United States)

    Karas, Steve; Olson Hunt, Megan J

    2014-05-01

    Randomized clinical trial. To determine the effectiveness of seated thoracic manipulation versus targeted supine thoracic manipulation on cervical spine pain and flexion range of motion (ROM). There is evidence that thoracic spine manipulation is an effective treatment for patients with cervical spine pain. This evidence includes a variety of techniques to manipulate the thoracic spine. Although each of them is effective, no research has compared techniques to determine which produces the best outcomes. A total of 39 patients with cervical spine pain were randomly assigned to either a seated thoracic manipulation or targeted supine thoracic manipulation group. Pain and flexion ROM measures were taken before and after the intervention. Pain reduction (post-treatment-pre-treatment) was significantly greater in those patients receiving the targeted supine thoracic manipulation compared to the seated thoracic manipulation (Pmanipulation group. The results of this study indicate that a targeted supine thoracic manipulation may be more effective in reducing cervical spine pain and improving cervical flexion ROM than a seated thoracic manipulation. Future studies should include a variety of patients and physical therapists (PTs) to validate our findings.

  10. Representational Momentum for the Human Body: Awkwardness Matters, Experience Does Not

    Science.gov (United States)

    Wilson, Margaret; Lancaster, Jessy; Emmorey, Karen

    2010-01-01

    Perception of the human body appears to involve predictive simulations that project forward to track unfolding body-motion events. Here we use representational momentum (RM) to investigate whether implicit knowledge of a learned arbitrary system of body movement such as sign language influences this prediction process, and how this compares to…

  11. Development of the ventral body wall in the human embryo

    NARCIS (Netherlands)

    Mekonen, Hayelom K.; Hikspoors, Jill P. J. M.; Mommen, Greet; Köhler, S. Eleonore; Lamers, Wouter H.

    2015-01-01

    Migratory failure of somitic cells is the commonest explanation for ventral body wall defects. However, the embryo increases ~ 25-fold in volume in the period that the ventral body wall forms, so that differential growth may, instead, account for the observed changes in topography. Human embryos

  12. Governing the postmortem procurement of human body material for research.

    Science.gov (United States)

    Van Assche, Kristof; Capitaine, Laura; Pennings, Guido; Sterckx, Sigrid

    2015-03-01

    Human body material removed post mortem is a particularly valuable resource for research. Considering the efforts that are currently being made to study the biochemical processes and possible genetic causes that underlie cancer and cardiovascular and neurodegenerative diseases, it is likely that this type of research will continue to gain in importance. However, post mortem procurement of human body material for research raises specific ethical concerns, more in particular with regard to the consent of the research participant. In this paper, we attempt to determine which consent regime should govern the post mortem procurement of body material for research. In order to do so, we assess the various arguments that could be put forward in support of a duty to make body material available for research purposes after death. We argue that this duty does in practice not support conscription but is sufficiently strong to defend a policy of presumed rather than explicit consent.

  13. Localization of the surgical bed using supine magnetic resonance and computed tomography scan fusion for planification of breast interstitial brachytherapy

    International Nuclear Information System (INIS)

    Jolicoeur, Marjory; Racine, Marie-Lynn; Trop, Isabelle; Hathout, Lara; Nguyen, David; Derashodian, Talar; David, Sandrine

    2011-01-01

    Purpose: To evaluate the feasibility of supine breast magnetic resonance imaging (MR) for definition and localization of the surgical bed (SB) after breast conservative surgery. To assess the inter-observer variability of surgical bed delineation on computed tomography (CT) and supine MR. Materials and methods: Patients candidate for breast brachytherapy and no contra-indications for MR were eligible for this study. Patients were placed in supine position, with the ipsilateral arm above the head in an immobilization device. All patients underwent CT and MR in the same implant/treatment position. Four points were predefined for CT-MRI image fusion. The surgical cavity was drawn on CT then MRI, by three independent observers. Fusion and analysis of CT and MR images were performed using the ECLIPSE treatment planning software. Results: From September 2005 to November 2008, 70 patients were included in this prospective study. For each patient, we were able to acquire axial T1 and T2 images of good quality. Using the predefined fusion points, the median error following the fusion was 2.7 mm. For each observer, volumes obtained on MR were, respectively, 30%, 38% and 40% smaller than those derived from CT images. A highly significant inter-observer variability in the delineation of the SB on CT was demonstrated (p < 0.0001). On the contrary, all three observers agreed on the volume of the SB drawn on MR. Conclusion: Supine breast MRI yields a more precise definition of the SB with a smaller inter-observer variability than CT and may obviate the need for surgical clips. The volume of the SB is smaller with MRI. In our opinion, CT-MRI fusion should be used for SB delineation, in view of partial breast irradiation.

  14. Investigation and Modeling of Capacitive Human Body Communication.

    Science.gov (United States)

    Zhu, Xiao-Qi; Guo, Yong-Xin; Wu, Wen

    2017-04-01

    This paper presents a systematic investigation of the capacitive human body communication (HBC). The measurement of HBC channels is performed using a novel battery-powered system to eliminate the effects of baluns, cables and instruments. To verify the measured results, a numerical model incorporating the entire HBC system is established. Besides, it is demonstrated that both the impedance and path gain bandwidths of HBC channels is affected by the electrode configuration. Based on the analysis of the simulated electric field distribution, an equivalent circuit model is proposed and the circuit parameters are extracted using the finite element method. The transmission capability along the human body is also studied. The simulated results using the numerical and circuit models coincide very well with the measurement, which demonstrates that the proposed circuit model can effectively interpret the operation mechanism of the capacitive HBC.

  15. Real-time stylistic prediction for whole-body human motions.

    Science.gov (United States)

    Matsubara, Takamitsu; Hyon, Sang-Ho; Morimoto, Jun

    2012-01-01

    The ability to predict human motion is crucial in several contexts such as human tracking by computer vision and the synthesis of human-like computer graphics. Previous work has focused on off-line processes with well-segmented data; however, many applications such as robotics require real-time control with efficient computation. In this paper, we propose a novel approach called real-time stylistic prediction for whole-body human motions to satisfy these requirements. This approach uses a novel generative model to represent a whole-body human motion including rhythmic motion (e.g., walking) and discrete motion (e.g., jumping). The generative model is composed of a low-dimensional state (phase) dynamics and a two-factor observation model, allowing it to capture the diversity of motion styles in humans. A real-time adaptation algorithm was derived to estimate both state variables and style parameter of the model from non-stationary unlabeled sequential observations. Moreover, with a simple modification, the algorithm allows real-time adaptation even from incomplete (partial) observations. Based on the estimated state and style, a future motion sequence can be accurately predicted. In our implementation, it takes less than 15 ms for both adaptation and prediction at each observation. Our real-time stylistic prediction was evaluated for human walking, running, and jumping behaviors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Thermoregulation under semi-natural conditions in speckled ...

    African Journals Online (AJOL)

    We recorded body temperature (Tb) in speckled mousebirds (Colius striatus) under semi-natural conditions in outdoor aviaries, and examined interactions between behavioural and metabolic thermoregulation by experimentally manipulating food availability and communal roosting behaviour. When food was available ad ...

  17. Optimization of wearable microwave antenna with simplified electromagnetic model of the human body

    Science.gov (United States)

    Januszkiewicz, Łukasz; Barba, Paolo Di; Hausman, Sławomir

    2017-12-01

    In this paper the problem of optimization design of a microwave wearable antenna is investigated. Reference is made to a specific antenna design that is a wideband Vee antenna the geometry of which is characterized by 6 parameters. These parameters were automatically adjusted with an evolution strategy based algorithm EStra to obtain the impedance matching of the antenna located in the proximity of the human body. The antenna was designed to operate in the ISM (industrial, scientific, medical) band which covers the frequency range of 2.4 GHz up to 2.5 GHz. The optimization procedure used the finite-difference time-domain method based full-wave simulator with a simplified human body model. In the optimization procedure small movements of antenna towards or away of the human body that are likely to happen during real use were considered. The stability of the antenna parameters irrespective of the movements of the user's body is an important factor in wearable antenna design. The optimization procedure allowed obtaining good impedance matching for a given range of antenna distances with respect to the human body.

  18. Supine breast US: how to correlate breast lesions from prone MRI.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato A; Angelelli, Giuseppe; Moschetta, Marco

    2016-01-01

    To evaluate spatial displacement of breast lesions from prone MR to supine ultrasound positions, and to determine whether the degree of displacement may be associated with breast density and lesion histotype. 380 patients underwent breast MR and second-look ultrasound. The MR and ultrasound lesion location within the breast gland, distances from anatomical landmarks (nipple, skin and pectoral muscle), spatial displacement (distance differences from the landmarks within the same breast region) and region displacement (breast region change) were prospectively evaluated. Differences between MR and ultrasound measurements, association between the degree of spatial displacement and both breast density and lesion histotypes were calculated. In 290/380 (76%) patients, 300 MR lesions were detected. 285/300 (95%) lesions were recognized on ultrasound. By comparing MR and ultrasound, spatial displacement occurred in 183/285 (64.3%) cases while region displacement in 102/285 (35.7%) cases with a circumferential movement along an arc centred on the nipple, having supine ultrasound as the reference standard. A significant association between the degree of lesion displacement and breast density was found (p < 0.00001) with a significant higher displacement in case of fatty breasts. No significant association between the degree of displacement and lesion histotype was found (p = 0.1). Lesion spatial displacement from MRI to ultrasound may occur especially in adipose breasts. Lesion-nipple distance and circumferential displacement from the nipple need to be considered for ultrasound lesion detection. Second-look ultrasound breast lesion detection could be improved by calculating the lesion-nipple distance and considering that spatial displacement from MRI occurs with a circumferential movement along an arc centred on the nipple.

  19. Impact of body position on central and peripheral hemodynamic contributions to movement-induced hyperemia: implications for rehabilitative medicine.

    Science.gov (United States)

    Trinity, Joel D; McDaniel, John; Venturelli, Massimo; Fjeldstad, Anette S; Ives, Stephen J; Witman, Melissa A H; Barrett-O'Keefe, Zachary; Amann, Markus; Wray, D Walter; Richardson, Russell S

    2011-05-01

    This study used alterations in body position to identify differences in hemodynamic responses to passive exercise. Central and peripheral hemodynamics were noninvasively measured during 2 min of passive knee extension in 14 subjects, whereas perfusion pressure (PP) was directly measured in a subset of 6 subjects. Movement-induced increases in leg blood flow (LBF) and leg vascular conductance (LVC) were more than twofold greater in the upright compared with supine positions (LBF, supine: 462 ± 6, and upright: 1,084 ± 159 ml/min, P different between positions (supine: 8 ± 1, and upright: 10 ± 1 beats/min, P = 0.22); however, the elevated HR was maintained for a longer duration when upright. Stroke volume contributed to the increase in cardiac output (CO) during the upright movement only. CO increased in both positions; however, the magnitude and duration of the CO response were greater in the upright position. Mean arterial pressure and PP were higher at baseline and throughout passive movement when upright. Thus exaggerated central hemodynamic responses characterized by an increase in stroke volume and a sustained HR response combined to yield a greater increase in CO during upright movement. This greater central response coupled with the increased PP and LVC explains the twofold greater and more sustained increase in movement-induced hyperemia in the upright compared with supine position and has clinical implications for rehabilitative medicine.

  20. Going to sleep in the supine position is a modifiable risk factor for late pregnancy stillbirth; Findings from the New Zealand multicentre stillbirth case-control study.

    Directory of Open Access Journals (Sweden)

    Lesley M E McCowan

    Full Text Available Our objective was to test the primary hypothesis that maternal non-left, in particular supine going-to-sleep position, would be a risk factor for late stillbirth (≥28 weeks of gestation.A multicentre case-control study was conducted in seven New Zealand health regions, between February 2012 and December 2015. Cases (n = 164 were women with singleton pregnancies and late stillbirth, without congenital abnormality. Controls (n = 569 were women with on-going singleton pregnancies, randomly selected and frequency matched for health region and gestation. The primary outcome was adjusted odds of late stillbirth associated with self-reported going-to-sleep position, on the last night. The last night was the night before the late stillbirth was thought to have occurred or the night before interview for controls. Going-to-sleep position on the last night was categorised as: supine, left-side, right-side, propped or restless. Multivariable logistic regression adjusted for known confounders.Supine going-to-sleep position on the last night was associated with increased late stillbirth risk (adjusted odds ratios (aOR 3.67, 95% confidence interval (CI 1.74 to 7.78 with a population attributable risk of 9.4%. Other independent risk factors for late stillbirth (aOR, 95% CI were: BMI (1.04, 1.01 to 1.08 per unit, maternal age ≥40 (2.88, 1.31 to 6.32, birthweight <10th customised centile (2.76, 1.59 to 4.80, and <6 hours sleep on the last night (1.81, 1.14 to 2.88. The risk associated with supine-going-to-sleep position was greater for term (aOR 10.26, 3.00 to 35.04 than preterm stillbirths (aOR 3.12, 0.97 to 10.05.Supine going-to-sleep position is associated with a 3.7 fold increase in overall late stillbirth risk, independent of other common risk factors. A public health campaign encouraging women not to go-to-sleep supine in the third trimester has potential to reduce late stillbirth by approximately 9%.

  1. Rupture of the Distal Biceps Tendon Combined with a Supinator Muscle Tear in a 51-Year-Old Woman: A Case Report

    Directory of Open Access Journals (Sweden)

    Samir Nayyar

    2011-01-01

    Full Text Available Distal biceps tendon rupture is a relatively uncommon occurrence in the general female population, and to our knowledge, has not been reported in association with a supinator muscle tear. We report a case of 51-year-old woman who experienced sharp pain in her forearm and elbow after lifting a heavy object. History and physical examination raised suspicion for a distal biceps tendon rupture. MRI imaging determined a combined distal biceps tendon tear with a supinator muscle tear with subsequent confirmation at surgery. Surgical repair was performed for the distal biceps tendon only through a single incision approach using the Endobutton technique.

  2. More accurate picture of human body organs

    International Nuclear Information System (INIS)

    Kolar, J.

    1985-01-01

    Computerized tomography and nucler magnetic resonance tomography (NMRT) are revolutionary contributions to radiodiagnosis because they allow to obtain a more accurate image of human body organs. The principles are described of both methods. Attention is mainly devoted to NMRT which has clinically only been used for three years. It does not burden the organism with ionizing radiation. (Ha)

  3. Total and regional deposition of inhaled aerosols in supine healthy subjects and subjects with mild-to-moderate COPD

    Energy Technology Data Exchange (ETDEWEB)

    Darquenne, Chantal; Lamm, Wayne J.; Fine, Janelle M.; Corley, Richard A.; Glenny, Robb W.

    2016-09-01

    Despite substantial development of sophisticated subject-specific computational models of aerosol transport and deposition in human lungs, experimental validation of predic- tions from these new models is sparse. We collected aerosol retention and exhalation profiles in seven healthy volunteers and six subjects with mild-to-moderate COPD (FEV1 ¼ 50–80%predicted) in the supine posture. Total deposition was measured during continuous breathing of 1 and 2.9 mm-diameter particles (tidal volume of 1 L, flow rate of 0.3 L/s and 0.75 L/s). Bolus inhalations of 1 mm particles were performed to penetration volumes of 200, 500 and 800 mL (flow rate of 0.5 L/s). Aerosol bolus dispersion (H), deposition, and mode shift (MS) were calculated from these data. There was no significant difference in total deposition between healthy subjects and those with COPD. Total deposition increased with increasing particle size and also with increasing flow rate. Similarly, there was no significant difference in aerosol bolus deposition between subject groups. Yet, the rate of increase in dispersion and of decrease in MS with increasing penetration volume was higher in subjects with COPD than in healthy volunteers (H: 0.79870.205 vs. 0.52770.122 mL/mL, p¼ 0.01; MS: - 0.27170.129 vs. - 0.145 70.076 mL/mL, p¼ 0.05) indicating larger ventilation inhomogeneities (based on H) and increased flow sequencing (based on MS) in the COPD than in the healthy group. In conclusion, in the supine posture, deposition appears to lack sensitivity for assessing the effect of lung morphology and/or ventilation distribution alteration induced by mild-to- moderate lung disease on the fate of inhaled aerosols. However, other parameters such as aerosol bolus dispersion and mode shift may be more sensitive parameters for evaluating models of lungs with moderate disease.

  4. Modal analysis of human body vibration model for Indian subjects under sitting posture.

    Science.gov (United States)

    Singh, Ishbir; Nigam, S P; Saran, V H

    2015-01-01

    Need and importance of modelling in human body vibration research studies are well established. The study of biodynamic responses of human beings can be classified into experimental and analytical methods. In the past few decades, plenty of mathematical models have been developed based on the diverse field measurements to describe the biodynamic responses of human beings. In this paper, a complete study on lumped parameter model derived from 50th percentile anthropometric data for a seated 54- kg Indian male subject without backrest support under free un-damped conditions has been carried out considering human body segments to be of ellipsoidal shape. Conventional lumped parameter modelling considers the human body as several rigid masses interconnected by springs and dampers. In this study, concept of mass of interconnecting springs has been incorporated and eigenvalues thus obtained are found to be closer to the values reported in the literature. Results obtained clearly establish decoupling of vertical and fore-and-aft oscillations. The mathematical modelling of human body vibration studies help in validating the experimental investigations for ride comfort of a sitting subject. This study clearly establishes the decoupling of vertical and fore-and-aft vibrations and helps in better understanding of possible human response to single and multi-axial excitations.

  5. Data Fusion Research of Triaxial Human Body Motion Gesture based on Decision Tree

    Directory of Open Access Journals (Sweden)

    Feihong Zhou

    2014-05-01

    Full Text Available The development status of human body motion gesture data fusion domestic and overseas has been analyzed. A triaxial accelerometer is adopted to develop a wearable human body motion gesture monitoring system aimed at old people healthcare. On the basis of a brief introduction of decision tree algorithm, the WEKA workbench is adopted to generate a human body motion gesture decision tree. At last, the classification quality of the decision tree has been validated through experiments. The experimental results show that the decision tree algorithm could reach an average predicting accuracy of 97.5 % with lower time cost.

  6. Prospective Assessment of Optimal Individual Position (Prone Versus Supine) for Breast Radiotherapy: Volumetric and Dosimetric Correlations in 100 Patients

    International Nuclear Information System (INIS)

    Lymberis, Stella C.; Wyngaert, John Keith de; Parhar, Preeti; Chhabra, Arpit M.; Fenton-Kerimian, Maria; Chang Jengwha; Hochman, Tsivia; Guth, Amber; Roses, Daniel; Goldberg, Judith D.; Formenti, Silvia C.

    2012-01-01

    Purpose: Damage to heart and lung from breast radiotherapy is associated with increased cardiovascular mortality and lung cancer development. We conducted a prospective study to evaluate which position is best to spare lung and heart from radiotherapy exposure. Methods and Materials: One hundred consecutive Stage 0–IIA breast cancer patients consented to participate in a research trial that required two computed tomography simulation scans for planning both supine and prone positions. The optimal position was defined as that which best covered the contoured breast and tumor bed while it minimized critical organ irradiation, as quantified by the in-field heart and lung volume. The trial was designed to plan the first 100 patients in each position to study correlations between in-field volumes of organs at risk and dose. Results: Fifty-three left and 47 right breast cancer patients were consecutively accrued to the trial. In all patients, the prone position was optimal for sparing lung volume compared to the supine setup (mean lung volume reduction was 93.5 cc for right and 103.6 cc for left breast cancer patients). In 46/53 (87%) left breast cancer patients best treated prone, in-field heart volume was reduced by a mean of 12 cc and by 1.8 cc for the other 7/53 (13%) patients best treated supine. As predicted, supine-prone differences in in-field volume and mean dose of heart and lung were highly correlated (Spearman's correlation coefficient for left breast cancer patients was 0.90 for heart and 0.94 for lung and 0.92 for right breast cancer patients for lung). Conclusions: Prone setup reduced the amount of irradiated lung in all patients and reduced the amount of heart volume irradiated in 87% of left breast cancer patients. In-field organ volume is a valid surrogate for predicting dose; the trial continued to the planned target of 400.

  7. An Impact of Thermodynamic Processes in Human Bodies on Performance Reliability of Individuals

    Directory of Open Access Journals (Sweden)

    Smalko Zbigniew

    2015-01-01

    Full Text Available The article presents the problem of the influence of thermodynamic factors on human fallibility in different zones of thermal discomfort. Describes the processes of energy in the human body. Been given a formal description of the energy balance of the human body thermoregulation. Pointed to human reactions to temperature changes of internal and external environment, including reactions associated with exercise. The methodology to estimate and determine the reliability of indicators of human basal acting in different zones of thermal discomfort. The significant effect of thermodynamic factors on the reliability and security ofperson.

  8. Earthing the Human Body Influences Physiologic Processes

    Science.gov (United States)

    Sokal, Karol

    2011-01-01

    Abstract Objectives This study was designed to answer the question: Does the contact of the human organism with the Earth via a copper conductor affect physiologic processes? Subjects and experiments Five (5) experiments are presented: experiment 1—effect of earthing on calcium–phosphate homeostasis and serum concentrations of iron (N = 84 participants); experiment 2—effect of earthing on serum concentrations of electrolytes (N = 28); experiment 3—effect of earthing on thyroid function (N = 12); experiment 4—effect of earthing on glucose concentration (N = 12); experiment 5—effect of earthing on immune response to vaccine (N = 32). Subjects were divided into two groups. One (1) group of people was earthed, while the second group remained without contact with the Earth. Blood and urine samples were examined. Results Earthing of an electrically insulated human organism during night rest causes lowering of serum concentrations of iron, ionized calcium, inorganic phosphorus, and reduction of renal excretion of calcium and phosphorus. Earthing during night rest decreases free tri-iodothyronine and increases free thyroxine and thyroid-stimulating hormone. The continuous earthing of the human body decreases blood glucose in patients with diabetes. Earthing decreases sodium, potassium, magnesium, iron, total protein, and albumin concentrations while the levels of transferrin, ferritin, and globulins α1, α2, β, and γ increase. These results are statistically significant. Conclusions Earthing the human body influences human physiologic processes. This influence is observed during night relaxation and during physical activity. Effect of the earthing on calcium–phosphate homeostasis is the opposite of that which occurs in states of weightlessness. It also increases the activity of catabolic processes. It may be the primary factor regulating endocrine and nervous systems. PMID:21469913

  9. Effect of Lumbar Disc Degeneration and Low-Back Pain on the Lumbar Lordosis in Supine and Standing

    DEFF Research Database (Denmark)

    Hansen, Bjarke B; Bendix, Tom; Grindsted, Jacob

    2015-01-01

    STUDY DESIGN: Cross-sectional study. OBJECTIVE: To examine the influence of low-back pain (LBP) and lumbar disc degeneration (LDD) on the lumbar lordosis in weight-bearing positional magnetic resonance imaging (pMRI). SUMMARY OF BACKGROUND DATA: The lumbar lordosis increases with a change...... of position from supine to standing and is known as an essential contributor to dynamic changes. However, the lordosis may be affected by disc degeneration and pain. METHODS: Patients with LBP >40 on a 0 to 100 mm Visual Analog Scale (VAS) both during activity and rest and a sex and age-decade matching...... control group without LBP were scanned in the supine and standing position in a 0.25-T open MRI unit. LDD was graded using Pfirrmann's grading-scale. Subsequently, the L2-to-S1 lumbar lordosis angle (LA) was measured. RESULTS: Thirty-eight patients with an average VAS of 58 (±13.8) mm during rest and 75...

  10. A long term model of circulation. [human body

    Science.gov (United States)

    White, R. J.

    1974-01-01

    A quantitative approach to modeling human physiological function, with a view toward ultimate application to long duration space flight experiments, was undertaken. Data was obtained on the effect of weightlessness on certain aspects of human physiological function during 1-3 month periods. Modifications in the Guyton model are reviewed. Design considerations for bilateral interface models are discussed. Construction of a functioning whole body model was studied, as well as the testing of the model versus available data.

  11. A Balanced-Fed Dual Inverted-F Antenna with Reduced Human Body Effects

    Directory of Open Access Journals (Sweden)

    Wang-Sang Lee

    2013-01-01

    Full Text Available A balanced-fed dual inverted-F antenna with reduced human body effects for WLAN applications at 2.45 GHz is presented. In order to reduce the influence by a close proximity or a touch of a human body, the proposed antenna employs an impedance matching using a lumped LC-balun which has the simple and compact structure applying for mobile handsets. The resonant frequency of the proposed antenna is fixed at 2.45 GHz regardless of the close proximity of a human body. By applying for the L-shape ground plane, the proposed antenna has the wide impedance bandwidth of about 150 MHz and the peak realized gain of about 4 dBi.

  12. Simulation of the infiltration process of a ceramic open-pore body with a metal alloy in semi-solid state to design the manufacturing of interpenetrating phase composites

    Science.gov (United States)

    Schomer, Laura; Liewald, Mathias; Riedmüller, Kim Rouven

    2018-05-01

    Metal-ceramic Interpenetrating Phase Composites (IPC) belong to a special subcategory of composite materials and reveal enhanced properties compared to conventional composite materials. Currently, IPC are produced by infiltration of a ceramic open-pore body with liquid metal applying high pressure and I or high temperature to avoid residual porosity. However, these IPC are not able to gain their complete potential, because of structural damages and interface reactions occurring during the manufacturing process. Compared to this, the manufacturing of IPC using the semi-solid forming technology offers great perspectives due to relative low processing temperatures and reduced mechanical pressure. In this context, this paper is focusing on numerical investigations conducted by using the FLOW-3D software for gaining a deeper understanding of the infiltration of open-pore bodies with semi-solid materials. For flow simulation analysis, a geometric model and different porous media drag models have been used. They have been adjusted and compared to get a precise description of the infiltration process. Based on these fundamental numerical investigations, this paper also shows numerical investigations that were used for basically designing a semi-solid forming tool. Thereby, the development of the flow front and the pressure during the infiltration represent the basis of the evaluation. The use of an open and closed tool cavity combined with various geometries of the upper die shows different results relating to these evaluation arguments. Furthermore, different overflows were designed and its effects on the pressure at the end of the infiltration process were investigated. Thus, this paper provides a general guideline for a tool design for manufacturing of metal-ceramic IPC using semi-solid forming.

  13. Effect of different seated positions on lung volume and oxygenation in acute respiratory distress syndrome.

    Science.gov (United States)

    Dellamonica, J; Lerolle, N; Sargentini, C; Hubert, S; Beduneau, G; Di Marco, F; Mercat, A; Diehl, J L; Richard, J C M; Bernardin, G; Brochard, L

    2013-06-01

    Lung volume available for ventilation is markedly decreased during acute respiratory distress syndrome. Body positioning may contribute to increase lung volume and partial verticalization is simple to perform. This study evaluated whether verticalization had parallel effects on oxygenation and end expiratory lung volume (EELV). Prospective multicenter study in 40 mechanically ventilated patients with ALI/ARDS in five university hospital MICUs. We evaluated four 45-min successive trunk position epochs (supine slightly elevated at 15°; semi recumbent with trunk elevated at 45°; seated with trunk elevated at 60° and legs down at 45°; back to supine). Arterial blood gases, EELV measured using the nitrogen washin/washout, and static compliance were measured. Responders were defined by a PaO₂/FiO₂ increase >20 % between supine and seated position. Results are median [25th-75th percentiles]. With median PEEP = 10 cmH₂O, verticalization increased lung volume but only responders (13 patients, 32 %) had a significant increase in EELV/PBW (predicted body weight) compared to baseline. This increase persisted at least partially when patients were positioned back to supine. Responders had a lower EELV/PBW supine [14 mL/kg (13-15) vs. 18 mL/kg (15-27) (p = 0.005)] and a lower compliance [30 mL/cmH₂O (22-38) vs. 42 (30-46) (p = 0.01)] than non-responders. Strain decreased with verticalization for responders. EELV/PBW increase and PaO₂/FiO₂ increase were not correlated. Verticalization is easily achieved and improves oxygenation in approximately 32 % of the patients together with an increase in EELV. Nonetheless, effect of verticalization on EELV/PBW is not predictable by PaO₂/FiO₂ increase, its monitoring may be helpful for strain optimization.

  14. Robotic Reconnaissance Missions to Small Bodies and Their Potential Contributions to Human Exploration

    Science.gov (United States)

    Abell, P. A.; Rivkin, A. S.

    2015-01-01

    Introduction: Robotic reconnaissance missions to small bodies will directly address aspects of NASA's Asteroid Initiative and will contribute to future human exploration. The NASA Asteroid Initiative is comprised of two major components: the Grand Challenge and the Asteroid Mission. The first component, the Grand Challenge, focuses on protecting Earth's population from asteroid impacts by detecting potentially hazardous objects with enough warning time to either prevent them from impacting the planet, or to implement civil defense procedures. The Asteroid Mission involves sending astronauts to study and sample a near- Earth asteroid (NEA) prior to conducting exploration missions of the Martian system, which includes Phobos and Deimos. The science and technical data obtained from robotic precursor missions that investigate the surface and interior physical characteristics of an object will help identify the pertinent physical properties that will maximize operational efficiency and reduce mission risk for both robotic assets and crew operating in close proximity to, or at the surface of, a small body. These data will help fill crucial strategic knowledge gaps (SKGs) concerning asteroid physical characteristics that are relevant for human exploration considerations at similar small body destinations. Small Body Strategic Knowledge Gaps: For the past several years NASA has been interested in identifying the key SKGs related to future human destinations. These SKGs highlight the various unknowns and/or data gaps of targets that the science and engineering communities would like to have filled in prior to committing crews to explore the Solar System. An action team from the Small Bodies Assessment Group (SBAG) was formed specifically to identify the small body SKGs under the direction of the Human Exploration and Operations Missions Directorate (HEOMD), given NASA's recent interest in NEAs and the Martian moons as potential human destinations [1]. The action team

  15. Alternated prone and supine whole-breast irradiation using IMRT: setup precision, respiratory movement and treatment time.

    Science.gov (United States)

    Veldeman, Liv; De Gersem, Werner; Speleers, Bruno; Truyens, Bart; Van Greveling, Annick; Van den Broecke, Rudy; De Neve, Wilfried

    2012-04-01

    The objective of this study was to compare setup precision, respiration-related breast movement and treatment time between prone and supine positions for whole-breast irradiation. Ten patients with early-stage breast carcinoma after breast-conserving surgery were treated with prone and supine whole breast-irradiation in a daily alternating schedule. Setup precision was monitored using cone-beam computed tomography (CBCT) imaging. Respiration-related breast movement in the vertical direction was assessed by magnetic sensors. The time needed for patient setup and for the CBCT procedure, the beam time, and the length of the whole treatment slot were also recorded. Random and systematic errors were not significantly different between positions in individual patients for each of the three axes (left-right, longitudinal, and vertical). Respiration-related movement was smaller in prone position, but about 80% of observations showed amplitudes movement was smaller in prone position. The longer treatment slots in prone position can probably be attributed to the higher repositioning need. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Measuring the thermal insulation and evaporative resistance of sleeping bags using a supine sweating fabric manikin

    International Nuclear Information System (INIS)

    Wu, Y S; Fan, Jintu

    2009-01-01

    For testing the thermal insulation of sleeping bags, standard test methods and procedures using heated manikins are provided in ASTM F1720-06 and EN 13537:2002. However, with regard to the evaporative resistance of sleeping bags, no instrument or test method has so far been established to give a direct measurement. In this paper, we report on a novel supine sweating fabric manikin system for directly measuring the evaporative resistance of sleeping bags. Eleven sleeping bags were tested using the manikin under the isothermal condition, namely, both the mean skin temperature of the manikin and that of the environment were controlled to be the same at 35 °C, with the wind speed and ambient relative humidity at 0.3 m s −1 and 50%, respectively. The results showed that the novel supine sweating fabric manikin is reproducible and accurate in directly measuring the evaporative resistance of sleeping bags, and the measured evaporative resistance can be combined with thermal insulation to calculate the moisture permeability index of sleeping bags

  17. Preference for human body odors is influenced by gender and sexual orientation.

    Science.gov (United States)

    Martins, Yolanda; Preti, George; Crabtree, Christina R; Runyan, Tamar; Vainius, Aldona A; Wysocki, Charles J

    2005-09-01

    Human body odor may contribute to selection of partners. If so, sexual orientation may influence preference for and perhaps production of human body odors. In a test of these hypotheses, heterosexual and homosexual males and females made two-alternative forced-choice preference judgments for body odors obtained from other heterosexual and homosexual males and females. Subjects chose between odors from (a) heterosexual males and gay males, (b) heterosexual males and heterosexual females, (c) heterosexual females and lesbians, and (d) gay males and lesbians. Results indicate that differences in body odor are detected and responded to on the basis of, in part, an individual's gender and sexual orientation. Possible mechanisms underlying these findings are discussed.

  18. Body Topography Parcellates Human Sensory and Motor Cortex.

    Science.gov (United States)

    Kuehn, Esther; Dinse, Juliane; Jakobsen, Estrid; Long, Xiangyu; Schäfer, Andreas; Bazin, Pierre-Louis; Villringer, Arno; Sereno, Martin I; Margulies, Daniel S

    2017-07-01

    The cytoarchitectonic map as proposed by Brodmann currently dominates models of human sensorimotor cortical structure, function, and plasticity. According to this model, primary motor cortex, area 4, and primary somatosensory cortex, area 3b, are homogenous areas, with the major division lying between the two. Accumulating empirical and theoretical evidence, however, has begun to question the validity of the Brodmann map for various cortical areas. Here, we combined in vivo cortical myelin mapping with functional connectivity analyses and topographic mapping techniques to reassess the validity of the Brodmann map in human primary sensorimotor cortex. We provide empirical evidence that area 4 and area 3b are not homogenous, but are subdivided into distinct cortical fields, each representing a major body part (the hand and the face). Myelin reductions at the hand-face borders are cortical layer-specific, and coincide with intrinsic functional connectivity borders as defined using large-scale resting state analyses. Our data extend the Brodmann model in human sensorimotor cortex and suggest that body parts are an important organizing principle, similar to the distinction between sensory and motor processing. © The Author 2017. Published by Oxford University Press.

  19. Lower core body temperature and greater body fat are components of a human thrifty phenotype.

    Science.gov (United States)

    Reinhardt, M; Schlögl, M; Bonfiglio, S; Votruba, S B; Krakoff, J; Thearle, M S

    2016-05-01

    In small studies, a thrifty human phenotype, defined by a greater 24-hour energy expenditure (EE) decrease with fasting, is associated with less weight loss during caloric restriction. In rodents, models of diet-induced obesity often have a phenotype including a reduced EE and decreased core body temperature. We assessed whether a thrifty human phenotype associates with differences in core body temperature or body composition. Data for this cross-sectional analysis were obtained from 77 individuals participating in one of two normal physiology studies while housed on our clinical research unit. Twenty-four-hour EE using a whole-room indirect calorimeter and 24-h core body temperature were measured during 24 h each of fasting and 200% overfeeding with a diet consisting of 50% carbohydrates, 20% protein and 30% fat. Body composition was measured by dual X-ray absorptiometry. To account for the effects of body size on EE, changes in EE were expressed as a percentage change from 24-hour EE (%EE) during energy balance. A greater %EE decrease with fasting correlated with a smaller %EE increase with overfeeding (r=0.27, P=0.02). The %EE decrease with fasting was associated with both fat mass and abdominal fat mass, even after accounting for covariates (β=-0.16 (95% CI: -0.26, -0.06) %EE per kg fat mass, P=0.003; β=-0.0004 (-0.0007, -0.00004) %EE kg(-1) abdominal fat mass, P=0.03). In men, a greater %EE decrease in response to fasting was associated with a lower 24- h core body temperature, even after adjusting for covariates (β=1.43 (0.72, 2.15) %EE per 0.1 °C, P=0.0003). Thrifty individuals, as defined by a larger EE decrease with fasting, were more likely to have greater overall and abdominal adiposity as well as lower core body temperature consistent with a more efficient metabolism.

  20. A comparative study of set up variations and bowel volumes in supine versus prone positions of patients treated with external beam radiation for carcinoma rectum.

    Science.gov (United States)

    Rajeev, K R; Menon, Smrithy S; Beena, K; Holla, Raghavendra; Kumar, R Rajaneesh; Dinesh, M

    2014-01-01

    A prospective study was undertaken to evaluate the influence of patient positioning on the set up variations to determine the planning target volume (PTV) margins and to evaluate the clinical relevance volume assessment of the small bowel (SB) within the irradiated volume. During the period of months from December 2011 to April 2012, a computed tomography (CT) scan was done either in supine position or in prone position using a belly board (BB) for 20 consecutive patients. All the patients had histologically proven rectal cancer and received either post- or pre-operative pelvic irradiation. Using a three-dimensional planning system, the dose-volume histogram for SB was defined in each axial CT slice. Total dose was 46-50 Gy (2 Gy/fraction), delivered using the 4-field box technique. The set up variation of the study group was assessed from the data received from the electronic portal imaging device in the linear accelerator. The shift along X, Y, and Z directions were noted. Both systematic and random errors were calculated and using both these values the PTV margin was calculated. The systematic errors of patients treated in the supine position were 0.87 (X-mm), 0.66 (Y-mm), 1.6 (Z-mm) and in the prone position were 1.3 (X-mm), 0.59 (Y-mm), 1.17 (Z-mm). The random errors of patients treated in the supine positions were 1.81 (X-mm), 1.73 (Y-mm), 1.83 (Z-mm) and in prone position were 2.02 (X-mm), 1.21 (Y-mm), 3.05 (Z-mm). The calculated PTV margins in the supine position were 3.45 (X-mm), 2.87 (Y-mm), 5.31 (Z-mm) and in the prone position were 4.91 (X-mm), 2.32 (Y-mm), 5.08 (Z-mm). The mean volume of the peritoneal cavity was 648.65 cm 3 in the prone position and 1197.37 cm 3 in the supine position. The prone position using BB device was more effective in reducing irradiated SB volume in rectal cancer patients. There were no significant variations in the daily set up for patients treated in both supine and prone positions.

  1. Robot and Human Surface Operations on Solar System Bodies

    Science.gov (United States)

    Weisbin, C. R.; Easter, R.; Rodriguez, G.

    2001-01-01

    This paper presents a comparison of robot and human surface operations on solar system bodies. The topics include: 1) Long Range Vision of Surface Scenarios; 2) Human and Robots Complement Each Other; 3) Respective Human and Robot Strengths; 4) Need More In-Depth Quantitative Analysis; 5) Projected Study Objectives; 6) Analysis Process Summary; 7) Mission Scenarios Decompose into Primitive Tasks; 7) Features of the Projected Analysis Approach; and 8) The "Getting There Effect" is a Major Consideration. This paper is in viewgraph form.

  2. Mechanical impedance of the human body in vertical direction.

    Science.gov (United States)

    Holmlund, P; Lundström, R; Lindberg, L

    2000-08-01

    The mechanical impedance of the human body in sitting posture and vertical direction was measured during different experimental conditions, such as vibration level (0.5-1.4 m/s2), frequency (2-100 Hz), body weight (57-92 kg), relaxed and erect upper body posture. The outcome shows that impedance increases with frequency up to a peak at about 5 Hz after which it decreases in a complex manner which includes two additional peaks. The frequency at which the first and second impedance peak occurs decreases with higher vibration level. Erect, compared with relaxed body posture resulted in higher impedance magnitudes and with peaks located at somewhat higher frequencies. Heavy persons show higher impedance magnitudes and peaks at lower frequencies.

  3. Brazilian legal and bioethical approach about donation for research and patents of human body parts.

    Science.gov (United States)

    Fernandes, Márcia Santana; Silla, Lúcia; Goldim, José Roberto; Martins-Costa, Judith

    2017-07-01

    The aim of this paper is to explain why the Brazilian legal system does not accept commercialization or commodification of human body parts, including genes or cells. As a consequence, in Brazil, the donation of human body parts for research-including basic or translational-must be made altruistically. For the same reason, the Brazilian patent system cannot be applied to human parts, cells or genes. Here, we present a qualitative analysis of juridical, bioethical, and social reasoning related to the legal status of human body parts especially in biobanks, as well as a description of the Brazilian legal system for clarification. Our aim is to discuss the responsibility of researchers for making available the scientific information resulting from scientific research and biobank storage of human body parts and to ensure the free utilization of knowledge in human health research.

  4. Redesigning Human Body Systems: Effective Pedagogical Strategy for Promoting Active Learning and STEM Education

    Directory of Open Access Journals (Sweden)

    Abour H. Cherif

    2012-01-01

    Full Text Available The human body is a remarkable biological machine maintained by interdependent body systems and organized biochemical reactions. Evolution has worked on humans for hundreds of thousands of years, yet the current pace of technological and social change have radically affected our life style and have exposed possible human frailties. This raises the question of whether or not nature’s work could be improved upon. We provide two-sided perspectives as a rationale for the need for the redesign of the human body. Then, we describe pedagogical strategy through which students study morphological and anatomical structures and the physiological functions of the human body systems and their respective organs and parts. The students select their own favorite system or organ to redesign in order to optimize the efficiency of the anatomical structural, physiological function, and/or the aesthetic and functional morphology; a redesign that might lead to, for example, lowering risk of diabetes, heart attack, and/or stroke. Through group work and interaction (student groups compete for a prestigious “in-house” patent award, students actively engage in the learning process in order to understand the role of design in the efficiency and functionality and vulnerability to disease of the human body system.

  5. Influence of the model's degree of freedom on human body dynamics identification.

    Science.gov (United States)

    Maita, Daichi; Venture, Gentiane

    2013-01-01

    In fields of sports and rehabilitation, opportunities of using motion analysis of the human body have dramatically increased. To analyze the motion dynamics, a number of subject specific parameters and measurements are required. For example the contact forces measurement and the inertial parameters of each segment of the human body are necessary to compute the joint torques. In this study, in order to perform accurate dynamic analysis we propose to identify the inertial parameters of the human body and to evaluate the influence of the model's number of degrees of freedom (DoF) on the results. We use a method to estimate the inertial parameters without torque sensor, using generalized coordinates of the base link, joint angles and external forces information. We consider a 34DoF model, a 58DoF model, as well as the case when the human is manipulating a tool (here a tennis racket). We compare the obtained in results in terms of contact force estimation.

  6. Performance of human body communication-based wearable ECG with capacitive coupling electrodes.

    Science.gov (United States)

    Sakuma, Jun; Anzai, Daisuke; Wang, Jianqing

    2016-09-01

    Wearable electrocardiogram (ECG) is attracting much attention in daily healthcare applications, and human body communication (HBC) technology provides an evident advantage in making the sensing electrodes of ECG also working for transmission through the human body. In view of actual usage in daily life, however, non-contact electrodes to the human body are desirable. In this Letter, the authors discussed the ECG circuit structure in the HBC-based wearable ECG for removing the common mode noise when employing non-contact capacitive coupling electrodes. Through the comparison of experimental results, they have shown that the authors' proposed circuit structure with the third electrode directly connected to signal ground can provide an effect on common mode noise reduction similar to the usual drive-right-leg circuit, and a sufficiently good acquisition performance of ECG signals.

  7. Embalmment: a veritable source of human body preservation ...

    African Journals Online (AJOL)

    Embalmment is the process of chemically treating the dead human body to reduce the presence and growth of microorganisms, in order to retard organic decomposition and restore acceptable physical appearance. This paper presents a synopsis of the historical aspect of embalming and the various documented ...

  8. Development of Swimming Human Simulation Model Considering Rigid Body Dynamics and Unsteady Fluid Force for Whole Body

    Science.gov (United States)

    Nakashima, Motomu; Satou, Ken; Miura, Yasufumi

    The purpose of this study is to develop a swimming human simulation model considering rigid body dynamics and unsteady fluid force for the whole body, which will be utilized to analyze various dynamical problems in human swimming. First, the modeling methods and their formulations for the human body and the fluid force are respectively described. Second, experiments to identify the coefficients of the normal drag and the added mass are conducted by use of an experimental setup, in which a limb model rotates in the water, and its rotating angle and the bending moment at the root are measured. As the result of the identification, the present model for the fluid force was found to have satisfactory performance in order to represent the unsteady fluctuations of the experimental data, although it has 10% error. Third, a simulation for the gliding position is conducted in order to identify the tangential drag coefficient. Finally, a simulation example of standard six beat front crawl swimming is shown. The swimming speed of the simulation became a reasonable value, indicating the validity of the present simulation model, although it is 7.5% lower than the actual swimming.

  9. Supine Craniospinal Irradiation Using Intrafractional Junction Shifts and Field-in-Field Dose Shaping: Early Experience at Methodist Hospital

    International Nuclear Information System (INIS)

    South, Michael C.; Chiu, J. Kam; Teh, Bin S.; Bloch, Charles; Schroeder, Thomas M.; Paulino, Arnold C.

    2008-01-01

    Purpose: To describe our preliminary experience with supine craniospinal irradiation. The advantages of the supine position for craniospinal irradiation include patient comfort, easier access to maintain an airway for anesthesia, and reduced variability of the head tilt in the face mask. Methods and Materials: The cranial fields were treated with near lateral fields and a table angle to match their divergence to the superior edge of the spinal field. The collimator was rotated to match the divergence from the superior spinal field. The spinal fields were treated using a source to surface distance (SSD) technique with the couch top at 100 cm. When a second spinal field was required, the table and collimator were rotated 90 o to allow for the use of the multileaf collimator and so the gantry could be rotated to match the divergence of the superior spinal field. The multileaf collimator was used for daily dynamic featherings and field-in-field dose control. Results: With a median follow-up of 20.2 months, five documented failures and no cases of radiation myelitis occurred in 23 consecutive patients. No failures occurred in the junctions of the spine-spine or brain-spine fields. Two failures occurred in the primary site alone, two in the spinal axis alone, and one primary site failure plus distant metastasis. The median time to recurrence was 17 months. Conclusion: The results of our study have shown that supine approach for delivering craniospinal irradiation is not associated with increased relapses at the field junctions. To date, no cases of radiation myelitis have developed

  10. Prostaglandins - universal biological regulators in the human body (literature review

    Directory of Open Access Journals (Sweden)

    О. V. Tymoshchuk

    2018-02-01

    Full Text Available Recently, researchers of different industries pay great attention to the problem of prostaglandins. Objective: to study and systematize the basic questions of structure, biological action and metabolism of prostaglandins in the human body and using their analogues in pharmacy through the domestic and foreign literature data analysis. Prostaglandins – biologically active substances which are similar in effect to hormones, but are synthesized in cells of different tissues. Prostaglandins as universal cellular mediators are widely distributed in the body, synthesized in small amounts in almost all tissues, have both local and systemic effects. For each prostaglandin there is a target organ. On chemical structure they are small molecules related to eicosanoids - a group of fat-like substances (lipids. Depending on the chemical structure prostaglandins are divided into series (A, B, C, D, E, F, G, H, I and J and three groups (1–3; type F isomers are to be indicated by additional letters α and β. Prostaglandins have an extremely wide range of physiological effects in the body and have three main functions: supporting, molecular, neurotransmitter. Most prostaglandins interact with specific receptors of plasma membranes, but some prostaglandins (group A can act without receptors. There is no stock of prostaglandins in the body, their life cycle is short, and they are quickly produced in response to biological stimulants exposure, have their effect in extremely small quantity and are rapidly inactivated in the bloodstream. Due to the extremely rapid breakdown of prostaglandins in the body they work near their place of secretion. Preparations of prostaglandins and their derivatives are used in experimental and clinical medicine for abortion and induction of labor, treatment of stomach ulcers, asthma, certain heart diseases, congenital heart defects in newborns, glaucoma, atherosclerosis, rheumatic and neurological diseases, kidney diseases, diabetes

  11. Assessment of body doses from photon exposures using human voxel models

    International Nuclear Information System (INIS)

    Zankl, M.; Fill, U.; Petoussi-Henss, N.; Regulla, D.

    2000-01-01

    For the scope of risk assessment in protection against ionising radiation (occupational, environmental and medical) it is necessary to determine the radiation dose to specific body organs and tissues. For this purpose, a series of models of the human body were designed in the past, together with computer codes simulating the radiation transport and energy deposition in the body. Most of the computational body models in use are so-called mathematical models; the most famous is the MIRD-5 phantom developed at Oak Ridge National Laboratory. In the 1980s, a new generation of human body models was introduced at GSF, constructed from whole body CT data. Due to being constructed from image data of real persons, these 'voxel models' offer an improved realism of external and internal shape of the body and its organs, compared to MIRD-type models. Comparison of dose calculations involving voxel models with respective dose calculations for MIRD-type models revealed that the deviation of the individual anatomy from that described in the MIRD-type models indeed introduces significant deviations of the calculated organ doses. Specific absorbed fractions of energy released in a source organ due to incorporated activity which are absorbed in target organs may differ by more than an order of magnitude between different body models; for external photon irradiation, the discrepancies are more moderate. (author)

  12. Computational modeling of blast wave interaction with a human body and assessment of traumatic brain injury

    Science.gov (United States)

    Tan, X. G.; Przekwas, A. J.; Gupta, R. K.

    2017-11-01

    The modeling of human body biomechanics resulting from blast exposure poses great challenges because of the complex geometry and the substantial material heterogeneity. We developed a detailed human body finite element model representing both the geometry and the materials realistically. The model includes the detailed head (face, skull, brain and spinal cord), the neck, the skeleton, air cavities (lungs) and the tissues. Hence, it can be used to properly model the stress wave propagation in the human body subjected to blast loading. The blast loading on the human was generated from a simulated C4 explosion. We used the highly scalable solvers in the multi-physics code CoBi for both the blast simulation and the human body biomechanics. The meshes generated for these simulations are of good quality so that relatively large time-step sizes can be used without resorting to artificial time scaling treatments. The coupled gas dynamics and biomechanics solutions were validated against the shock tube test data. The human body models were used to conduct parametric simulations to find the biomechanical response and the brain injury mechanism due to blasts impacting the human body. Under the same blast loading condition, we showed the importance of inclusion of the whole body.

  13. Systematic feasibility analysis of a quantitative elasticity estimation for breast anatomy using supine/prone patient postures.

    Science.gov (United States)

    Hasse, Katelyn; Neylon, John; Sheng, Ke; Santhanam, Anand P

    2016-03-01

    Breast elastography is a critical tool for improving the targeted radiotherapy treatment of breast tumors. Current breast radiotherapy imaging protocols only involve prone and supine CT scans. There is a lack of knowledge on the quantitative accuracy with which breast elasticity can be systematically measured using only prone and supine CT datasets. The purpose of this paper is to describe a quantitative elasticity estimation technique for breast anatomy using only these supine/prone patient postures. Using biomechanical, high-resolution breast geometry obtained from CT scans, a systematic assessment was performed in order to determine the feasibility of this methodology for clinically relevant elasticity distributions. A model-guided inverse analysis approach is presented in this paper. A graphics processing unit (GPU)-based linear elastic biomechanical model was employed as a forward model for the inverse analysis with the breast geometry in a prone position. The elasticity estimation was performed using a gradient-based iterative optimization scheme and a fast-simulated annealing (FSA) algorithm. Numerical studies were conducted to systematically analyze the feasibility of elasticity estimation. For simulating gravity-induced breast deformation, the breast geometry was anchored at its base, resembling the chest-wall/breast tissue interface. Ground-truth elasticity distributions were assigned to the model, representing tumor presence within breast tissue. Model geometry resolution was varied to estimate its influence on convergence of the system. A priori information was approximated and utilized to record the effect on time and accuracy of convergence. The role of the FSA process was also recorded. A novel error metric that combined elasticity and displacement error was used to quantify the systematic feasibility study. For the authors' purposes, convergence was set to be obtained when each voxel of tissue was within 1 mm of ground-truth deformation. The authors

  14. Isomap transform for segmenting human body shapes.

    Science.gov (United States)

    Cerveri, P; Sarro, K J; Marchente, M; Barros, R M L

    2011-09-01

    Segmentation of the 3D human body is a very challenging problem in applications exploiting volume capture data. Direct clustering in the Euclidean space is usually complex or even unsolvable. This paper presents an original method based on the Isomap (isometric feature mapping) transform of the volume data-set. The 3D articulated posture is mapped by Isomap in the pose of Da Vinci's Vitruvian man. The limbs are unrolled from each other and separated from the trunk and pelvis, and the topology of the human body shape is recovered. In such a configuration, Hoshen-Kopelman clustering applied to concentric spherical shells is used to automatically group points into the labelled principal curves. Shepard interpolation is utilised to back-map points of the principal curves into the original volume space. The experimental results performed on many different postures have proved the validity of the proposed method. Reliability of less than 2 cm and 3° in the location of the joint centres and direction axes of rotations has been obtained, respectively, which qualifies this procedure as a potential tool for markerless motion analysis.

  15. ¿Disposable Matter or Personal Entity? The Human Body, Biotechnology and the Juridical Requirements of Dignity

    Directory of Open Access Journals (Sweden)

    Jorge Nicolás Lafferriere

    2018-01-01

    Full Text Available Biotechnological interventions affect the human body in new and powerful ways in the process of procreation, through actions of enhancement or replacement of the body, or by the search of the immortality of the body. This implies new legal challenges to prevent biotechnoscience from considering the human body as "operable and disposable matter", and treating it as the human person himself. In this article, we will study these challenges, starting from human dignity as a fundamental principle for an assessment of this biotechnology, and focusing on four legal issues: improvement interventions and their legal enforceability; the commodification of human life; growing social inequalities and the emergence of new forms of discrimination; and the principle of integrity of the human species.

  16. Human body contour data based activity recognition.

    Science.gov (United States)

    Myagmarbayar, Nergui; Yuki, Yoshida; Imamoglu, Nevrez; Gonzalez, Jose; Otake, Mihoko; Yu, Wenwei

    2013-01-01

    This research work is aimed to develop autonomous bio-monitoring mobile robots, which are capable of tracking and measuring patients' motions, recognizing the patients' behavior based on observation data, and providing calling for medical personnel in emergency situations in home environment. The robots to be developed will bring about cost-effective, safe and easier at-home rehabilitation to most motor-function impaired patients (MIPs). In our previous research, a full framework was established towards this research goal. In this research, we aimed at improving the human activity recognition by using contour data of the tracked human subject extracted from the depth images as the signal source, instead of the lower limb joint angle data used in the previous research, which are more likely to be affected by the motion of the robot and human subjects. Several geometric parameters, such as, the ratio of height to weight of the tracked human subject, and distance (pixels) between centroid points of upper and lower parts of human body, were calculated from the contour data, and used as the features for the activity recognition. A Hidden Markov Model (HMM) is employed to classify different human activities from the features. Experimental results showed that the human activity recognition could be achieved with a high correct rate.

  17. Human body scents: do they influence our behavior?

    Science.gov (United States)

    Mildner, Sophie; Buchbauer, Gerhard

    2013-11-01

    Pheromonal communication in the animal world has been of great research interest for a long time. While extraordinary discoveries in this field have been made, the importance of the human sense of smell was of far lower interest. Humans are seen as poor smellers and therefore research about human olfaction remains quite sparse compared with other animals. Nevertheless amazing achievements have been made during the past 15 years. This is a collection of available data on this topic and a controversial discussion on the role of putative human pheromones in our modem way of living. While the focus was definitely put on behavioral changes evoked by putative human pheromones this article also includes other important aspects such as the possible existence of a human vomeronasal organ. If pheromones do have an influence on human behavior there has to be a receptor organ. How are human body scents secreted and turned into odorous substances? And how can con-specifics detect those very odors and transmit them to the brain? Apart from that the most likely candidates for human pheromones are taken on account and their impact on human behavior is shown in various detail.

  18. Analysis of measured data of human body based on error correcting frequency

    Science.gov (United States)

    Jin, Aiyan; Peipei, Gao; Shang, Xiaomei

    2014-04-01

    Anthropometry is to measure all parts of human body surface, and the measured data is the basis of analysis and study of the human body, establishment and modification of garment size and formulation and implementation of online clothing store. In this paper, several groups of the measured data are gained, and analysis of data error is gotten by analyzing the error frequency and using analysis of variance method in mathematical statistics method. Determination of the measured data accuracy and the difficulty of measured parts of human body, further studies of the causes of data errors, and summarization of the key points to minimize errors possibly are also mentioned in the paper. This paper analyses the measured data based on error frequency, and in a way , it provides certain reference elements to promote the garment industry development.

  19. Plantar flexor stretch reflex responses to whole body loading/unloading during human walking

    DEFF Research Database (Denmark)

    Grey, Michael James; van Doornik, Johannes; Sinkjær, Thomas

    2002-01-01

    Numerous animal and human studies have shown that afferent information from the periphery contributes to the control of walking. In particular, recent studies have consistently shown that load receptor input is an important element of the locomotion control mechanism. The objective of this study...... perturbation during human walking. Three body load conditions were investigated: normal body load, a 30% increase in body load, and a 30% decrease in body load. Healthy subjects walked on a treadmill at approximately 3.6 km/h with the left ankle attached to a portable stretching device. Dorsiflexion...... strongly to the corrective response of the stretch reflex in the plantar flexor muscles during walking....

  20. The Major Histocompatibility Complex and Perfumers' Descriptions of Human Body Odors

    Directory of Open Access Journals (Sweden)

    Claus Wedekind

    2007-04-01

    Full Text Available The MHC (major histocompatibility complex is a group of genes that play a crucial role in immune recognition and in tolerance of tissue grafting. The MHC has also been found to influence body odors, body odor preferences, and mate choice in mice and humans. Here we test whether verbal descriptions of human body odors can be linked to the MHC. We asked 45 male students to live as odor neutral as possible for two consecutive days and to wear a T-shirt during the nights. The odors of these T-shirts were then described by five evaluators: two professional perfumers and three laymen. One of the perfumers was able to describe the T-shirt odors in such a way that some of the allelic specificity of the MHC was significantly revealed (after Bonferroni correction for multiple testing. This shows that, although difficult, some people are able to describe MHC-correlated body odor components.

  1. Lack of body positional effects on paresthesias when stimulating the dorsal root ganglion (DRG) in the treatment of chronic pain.

    Science.gov (United States)

    Kramer, Jeffery; Liem, Liong; Russo, Marc; Smet, Iris; Van Buyten, Jean-Pierre; Huygen, Frank

    2015-01-01

    One prominent side effect from neurostimulation techniques, and in particular spinal cord stimulation (SCS), is the change in intensity of stimulation when moving from an upright (vertical) to a recumbent or supine (horizontal) position and vice versa. It is well understood that the effects of gravity combined with highly conductive cerebrospinal fluid provide the mechanism by which changes in body position can alter the intensity of stimulation-induced paresthesias. While these effects are well established for leads that are placed within the more medial aspects of the spinal canal, little is known about these potential effects in leads placed in the lateral epidural space and in particular within the neural foramina near the dorsal root ganglion (DRG). We prospectively validated a newly developed paresthesia intensity rating scale and compared perceived paresthesia intensities when subjects assumed upright vs. supine bodily positions during neuromodulation of the DRG. On average, the correlation coefficient between stimulation intensity (pulse amplitude) and perceived paresthesia intensity was 0.83, demonstrating a strong linear relationship. No significant differences in paresthesia intensities were reported within subjects when moving from an upright (4.5 ± 0.14) to supine position 4.5 (± 0.12) (p > 0.05). This effect persisted through 12 months following implant. Neuromodulation of the DRG produces paresthesias that remain consistent across body positions, suggesting that this paradigm may be less susceptible to positional effects than dorsal column stimulation. © 2014 International Neuromodulation Society.

  2. An investigation on the assessed thermal sensation and human body exergy consumption rate

    DEFF Research Database (Denmark)

    Simone, Angela; Kolarik, Jakub; Iwamatsu, Toshiya

    2010-01-01

    perception of the indoor environment is rare. As the building should provide healthy and comfortable environment for its occupants, it is reasonable to consider both the exergy flows in the building and within the human body. A relatively new approach of the relation between the exergy concept and the built......-environment research has been explored in the present work. The relationship of subjectively assessed thermal sensation data, from earlier thermal comfort studies, to the calculated human-body exergy consumption has been analysed. The results show that the minimum human body exergy consumption rate was related......The exergy concept helps to optimize indoor climate conditioning systems to meet the requirements of sustainable building design. While the exergy approach to design and operation of indoor climate conditioning systems is relatively well established, its exploitation in connection to human...

  3. Students' Conceptions about Energy and the Human Body

    Science.gov (United States)

    Mann, Michael; Treagust, David F.

    2010-01-01

    Students' understanding of energy has been primarily within the domain of physics. This study sought to examine students' understanding of concepts relating to energy and the human body using pencil and paper questionnaires administered to 610 students in Years 8-12. From students' responses to the questionnaires, conceptual patterns were…

  4. Genotyping of human lice suggests multiple emergencies of body lice from local head louse populations.

    Directory of Open Access Journals (Sweden)

    Wenjun Li

    Full Text Available BACKGROUND: Genetic analyses of human lice have shown that the current taxonomic classification of head lice (Pediculus humanus capitis and body lice (Pediculus humanus humanus does not reflect their phylogenetic organization. Three phylotypes of head lice A, B and C exist but body lice have been observed only in phylotype A. Head and body lice have different behaviours and only the latter have been involved in outbreaks of infectious diseases including epidemic typhus, trench fever and louse borne recurrent fever. Recent studies suggest that body lice arose several times from head louse populations. METHODS AND FINDINGS: By introducing a new genotyping technique, sequencing variable intergenic spacers which were selected from louse genomic sequence, we were able to evaluate the genotypic distribution of 207 human lice. Sequence variation of two intergenic spacers, S2 and S5, discriminated the 207 lice into 148 genotypes and sequence variation of another two intergenic spacers, PM1 and PM2, discriminated 174 lice into 77 genotypes. Concatenation of the four intergenic spacers discriminated a panel of 97 lice into 96 genotypes. These intergenic spacer sequence types were relatively specific geographically, and enabled us to identify two clusters in France, one cluster in Central Africa (where a large body louse outbreak has been observed and one cluster in Russia. Interestingly, head and body lice were not genetically differentiated. CONCLUSIONS: We propose a hypothesis for the emergence of body lice, and suggest that humans with both low hygiene and head louse infestations provide an opportunity for head louse variants, able to ingest a larger blood meal (a required characteristic of body lice, to colonize clothing. If this hypothesis is ultimately supported, it would help to explain why poor human hygiene often coincides with outbreaks of body lice. Additionally, if head lice act as a reservoir for body lice, and that any social degradation in

  5. The study of human bodies' impedance networks in testing leakage currents of electrical equipments

    Science.gov (United States)

    Zhang, Zhaohui; Wang, Xiaofei

    2006-11-01

    In the testing of electrical equipments' leakage currents, impedance networks of human bodies are used to simulate the current's effect on human bodies, and they are key to the preciseness of the testing result. This paper analyses and calculates three human bodies' impedance networks of measuring electric burn current, perception or reaction current, let-go current in IEC60990, by using Matlab, compares the research result of current effect thresholds' change with sine wave's frequency published in IEC479-2, and amends parameters of measuring networks. It also analyses the change of perception or reaction current with waveform by Multisim.

  6. A Novel Human Body Area Network for Brain Diseases Analysis.

    Science.gov (United States)

    Lin, Kai; Xu, Tianlang

    2016-10-01

    Development of wireless sensor and mobile communication technology provide an unprecedented opportunity for realizing smart and interactive healthcare systems. Designing such systems aims to remotely monitor the health and diagnose the diseases for users. In this paper, we design a novel human body area network for brain diseases analysis, which is named BABDA. Considering the brain is one of the most complex organs in the human body, the BABDA system provides four function modules to ensure the high quality of the analysis result, which includes initial data collection, data correction, data transmission and comprehensive data analysis. The performance evaluation conducted in a realistic environment with several criteria shows the availability and practicability of the BABDA system.

  7. [Anatomia sacra. Religiously motivated interventions on human or animal bodies].

    Science.gov (United States)

    Gladigow, B

    1995-01-01

    Controlled surgery in the interior of human or animal bodies in classical antiquity was allowed only under certain circumstances. Bloody animal sacrifice and its rules for the interpretation of entrails as well as the rare examples of 'ritual anatomy' presented a religious framework for the opening of bodies. Greek mythology provided several examples of medical operations, for example, the Caesarean section, transplantations and plastic surgery. Great cultic significance was given to organ votives or reproductions of human inner organs which were offered in temples ex voto or with request for their curing. The anatomical knowledge transported along with these offerings represents a separate tradition different from the state of anatomical knowledge found in medical literature of the period.

  8. A Managerial Approach To A Controversial Exhibition: The Human Body

    Directory of Open Access Journals (Sweden)

    Viorica Aura Păuş

    2013-12-01

    Full Text Available This paper will analyse the reception of the Human Body exhibition of 2013 in Romania, from a managerial point of view. The research is based on the exhibition visitors’ book, to which a content analysis was applied. The main aim of the paper is to investigate how the ‘Grigore Antipa’ Museum (Romania constructed the cultural context in which the scientific arguments prevailed over the religious ones, turning the exhibition of plastinated human bodies into an accepted public event, with a strong emphasis on education and science (medicine. At the same time, ethical concerns and religious criticism were downplayed by maintaining the focus on the ‘education for health’ frame.

  9. Effect of the supine position on uterine and umbilical blood flow during the third trimester of uncomplicated pregnancies in multiparous patients.

    Science.gov (United States)

    Jaffa, A J; Gull, I; Amster, R; Lessing, J B; Wolman, I

    2001-01-01

    We established the effects of the supine position on umbilical blood flow when measured during the third trimester in 30 multiparous, normotensive patients. Blood flow in the umbilical and uterine arteries and blood pressure in the brachial and popliteal arteries were blindly taken by two different observers: first in the lateral and 5 min later in the supine position. There was a significant difference in mean blood pressure between the two postures. However, there was no statistical difference in the pulse pressure or in systolic/diastolic ratio in the umbilical and uterine arteries between the two positions. Postural changes in normotensive multiparous patients do not affect uterine and umbilical blood flow during the third trimester of uncomplicated pregnancies. Copyright 2001 S. Karger AG, Basel

  10. Radionuclide withdrawal from animal and human body

    International Nuclear Information System (INIS)

    Arkhipov, A.S.; Sidorova, T.F.

    1995-01-01

    The authors review the history of the problem of radionuclide withdrawal from animal and human body and discuss methodological approaches to it. Results of studies of radionuclide elimination by means of chemical and bioactive substances are analyzed. Special attention is paid to decorporation of radioactive elements which are the most hazardous as regards intoxication in connection with the Chernobyl accident: 131 I, 89 St and 90 Sr, 137 Cs, 238 Pu, and 241 Am. The authors analyze the results of studies of radionuclide withdrawal based on the dissolution effect, ionic antagonism, and by means of complexons, carried out in humans and animals. Efficacies of alimentary fibers and other adsorbents, foodstuffs and drinks are demonstrated. 48 refs

  11. Quantitative cardiovascular magnetic resonance in pregnant women: cross-sectional analysis of physiological parameters throughout pregnancy and the impact of the supine position.

    Science.gov (United States)

    Rossi, Alexia; Cornette, Jerome; Johnson, Mark R; Karamermer, Yusuf; Springeling, Tirza; Opic, Petra; Moelker, Adriaan; Krestin, Gabriel P; Steegers, Eric; Roos-Hesselink, Jolien; van Geuns, Robert-Jan M

    2011-06-27

    There are physiological reasons for the effects of positioning on hemodynamic variables and cardiac dimensions related to altered intra-abdominal and intra-thoracic pressures. This problem is especially evident in pregnant women due to the additional aorto-caval compression by the enlarged uterus. The purpose of this study was to investigate the effect of postural changes on cardiac dimensions and function during mid and late pregnancy using cardiovascular magnetic resonance (CMR). Healthy non-pregnant women, pregnant women at 20th week of gestation and at 32nd week of gestation without history of cardiac disease were recruited to the study and underwent CMR in supine and left lateral positions. Cardiac hemodynamic parameters and dimensions were measured and compared between both positions. Five non-pregnant women, 6 healthy pregnant women at mid pregnancy and 8 healthy pregnant women at late pregnancy were enrolled in the study. In the group of non-pregnant women left ventricular (LV) cardiac output (CO) significantly decreased by 9% (p=0.043) and right ventricular (RV) end-diastolic volume (EDV) significantly increased by 5% (p=0.043) from the supine to the left lateral position. During mid pregnancy LV ejection fraction (EF), stroke volume (SV), left atrium lateral diameter and left atrial supero-inferior diameter increased significantly from the supine position to the left lateral position: 8%, 27%, 5% and 11%, respectively (ppregnancy a significant increment of LV EF, EDV, SV and CO was observed in the left lateral position: 11%, 21%, 35% and 24% (ppregnancy positional changes affect significantly cardiac hemodynamic parameters and dimensions. Pregnant women who need serial studies by CMR should be imaged in a consistent position. From as early as 20 weeks the left lateral position should be preferred on the supine position because it positively affects venous return, SV and CO.

  12. Quantitative cardiovascular magnetic resonance in pregnant women: cross-sectional analysis of physiological parameters throughout pregnancy and the impact of the supine position

    Directory of Open Access Journals (Sweden)

    Moelker Adriaan

    2011-06-01

    Full Text Available Abstract Background There are physiological reasons for the effects of positioning on hemodynamic variables and cardiac dimensions related to altered intra-abdominal and intra-thoracic pressures. This problem is especially evident in pregnant women due to the additional aorto-caval compression by the enlarged uterus. The purpose of this study was to investigate the effect of postural changes on cardiac dimensions and function during mid and late pregnancy using cardiovascular magnetic resonance (CMR. Methods Healthy non-pregnant women, pregnant women at 20th week of gestation and at 32nd week of gestation without history of cardiac disease were recruited to the study and underwent CMR in supine and left lateral positions. Cardiac hemodynamic parameters and dimensions were measured and compared between both positions. Results Five non-pregnant women, 6 healthy pregnant women at mid pregnancy and 8 healthy pregnant women at late pregnancy were enrolled in the study. In the group of non-pregnant women left ventricular (LV cardiac output (CO significantly decreased by 9% (p = 0.043 and right ventricular (RV end-diastolic volume (EDV significantly increased by 5% (p = 0.043 from the supine to the left lateral position. During mid pregnancy LV ejection fraction (EF, stroke volume (SV, left atrium lateral diameter and left atrial supero-inferior diameter increased significantly from the supine position to the left lateral position: 8%, 27%, 5% and 11%, respectively (p Conclusions During pregnancy positional changes affect significantly cardiac hemodynamic parameters and dimensions. Pregnant women who need serial studies by CMR should be imaged in a consistent position. From as early as 20 weeks the left lateral position should be preferred on the supine position because it positively affects venous return, SV and CO.

  13. A REVIEW ON LOWER APPENDICULAR MUSCULOSKELETAL SYSTEM OF HUMAN BODY

    Directory of Open Access Journals (Sweden)

    M. Akhtaruzzaman

    2016-04-01

    Full Text Available Rehabilitation engineering plays an important role in designing various autonomous robots to provide better therapeutic exercise to disabled patients. Hence it is necessary to study human musculoskeletal system and also needs to be presented in scientific manner in order to describe and analyze the biomechanics of human body motion. This review focuses on lower appendicular musculoskeletal structure of human body to represent joints and links architectures; to identify muscle attachments and functions; and to illustrate muscle groups which are responsible for a particular joint movement. Firstly, human lower skeletal structure, linking systems, joint mechanisms, and their functions are described with a conceptual representation of joint architecture of human skeleton. This section also represents joints and limbs by comparing with mechanical systems. Characteristics of ligaments and their functions to construct skeletal joints are also discussed briefly in this part. Secondly, the study focuses on muscular system of human lower limbs where muscle structure, functions, roles in moving endoskeleton structure, and supporting mechanisms are presented ellaborately. Thirdly, muscle groups are tabulated based on functions that provide mobility to different joints of lower limbs. Finally, for a particular movement action of lower extremity, muscles are also grouped and tabulated to have a better understanding on functions of individual muscle. Basically the study presents an overview of the structure of human lower limbs by characterizing and classifying skeletal and muscular systems.KEYWORDS:   Musculoskeletal system; Human lower limbs; Muscle groups; Joint motion; Biomechatronics; Rehabilitation.

  14. NIH Human Microbiome Project defines normal bacterial makeup of the body

    Science.gov (United States)

    Microbes inhabit just about every part of the human body, living on the skin, in the gut, and up the nose. Sometimes they cause sickness, but most of the time, microorganisms live in harmony with their human hosts, providing vital functions essential for

  15. [Fractionation of hydrogen stable isotopes in the human body].

    Science.gov (United States)

    Siniak, Iu E; Grigor'ev, A I; Skuratov, V M; Ivanova, S M; Pokrovskiĭ, B G

    2006-01-01

    Fractionation of hydrogen stable isotopes was studied in 9 human subjects in a chamber with normal air pressure imitating a space cabin. Mass-spectrometry of isotopes in blood, urine, saliva, and potable water evidenced increases in the contents of heavy H isotope (deuterium) in the body liquids as compared with water. These results support one of the theories according to which the human organism eliminates heavy stable isotopes of biogenous chemical elements.

  16. High energy radiation effects on the human body

    International Nuclear Information System (INIS)

    Kato, Kazuaki

    1977-01-01

    High-energy radiation injuries and their risks were recognized, information on low-energy radiation injuries was also arranged, and with these backgrounds, countermeasures against prevention of radiation injuries were considered. Redintegration of DNA and mutation by radiation were described, and relationship between radiation injuries and dose was considered. Interaction of high-energy radiation and substances in the living body and injuries by the interaction were also considered. Expression method of risk was considered, and a concept of protection dose was suggested. Protection dose is dose equivalent which is worthy of value at the point where the ratio to permissible dose distributed among each part of the body is at its maximum in the distribution of dose equivalent formed within the body when standard human body is placed at a certain radiation field for a certain time. Significance and countermeasures of health examination which is under an abligation to make radiation workers receive health check were thought, and problems were proposed on compensation when radiation injuries should appear actually. (Tsunoda, M.)

  17. Magnetic Resonance Imaging Assessment of Spinal Cord and Cauda Equina Motion in Supine Patients With Spinal Metastases Planned for Spine Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Tseng, Chia-Lin [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Sussman, Marshall S. [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Atenafu, Eshetu G. [Department of Biostatistics, University Health Network, University of Toronto, Toronto, Ontario (Canada); Letourneau, Daniel [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Ma, Lijun [Department of Radiation Oncology, University of California San Francisco, San Francisco, California (United States); Soliman, Hany; Thibault, Isabelle [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Cho, B. C. John; Simeonov, Anna [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Yu, Eugene [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Fehlings, Michael G. [Department of Neurosurgery and Spine Program, Toronto Western Hospital, University of Toronto, Toronto, Ontario (Canada); Sahgal, Arjun, E-mail: arjun.sahgal@sunnybrook.ca [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada)

    2015-04-01

    Purpose: To assess motion of the spinal cord and cauda equina, which are critical neural tissues (CNT), which is important when evaluating the planning organ-at-risk margin required for stereotactic body radiation therapy. Methods and Materials: We analyzed CNT motion in 65 patients with spinal metastases (11 cervical, 39 thoracic, and 24 lumbar spinal segments) in the supine position using dynamic axial and sagittal magnetic resonance imaging (dMRI, 3T Verio, Siemens) over a 137-second interval. Motion was segregated according to physiologic cardiorespiratory oscillatory motion (characterized by the average root mean square deviation) and random bulk shifts associated with gross patient motion (characterized by the range). Displacement was evaluated in the anteroposterior (AP), lateral (LR), and superior-inferior (SI) directions by use of a correlation coefficient template matching algorithm, with quantification of random motion measure error over 3 separate trials. Statistical significance was defined according to P<.05. Results: In the AP, LR, and SI directions, significant oscillatory motion was observed in 39.2%, 35.1%, and 10.8% of spinal segments, respectively, and significant bulk motions in all cases. The median oscillatory CNT motions in the AP, LR, and SI directions were 0.16 mm, 0.17 mm, and 0.44 mm, respectively, and the maximal statistically significant oscillatory motions were 0.39 mm, 0.41 mm, and 0.77 mm, respectively. The median bulk displacements in the AP, LR, and SI directions were 0.51 mm, 0.59 mm, and 0.66 mm, and the maximal statistically significant displacements were 2.21 mm, 2.87 mm, and 3.90 mm, respectively. In the AP, LR, and SI directions, bulk displacements were greater than 1.5 mm in 5.4%, 9.0%, and 14.9% of spinal segments, respectively. No significant differences in axial motion were observed according to cord level or cauda equina. Conclusions: Oscillatory CNT motion was observed to be relatively minor. Our results

  18. Venoconstrictor agents mobilize blood from different sources and increase intrathoracic filling during epidural anesthesia in supine humans

    International Nuclear Information System (INIS)

    Stanton-Hicks, M.; Hoeck, A.S.; Stuehmeier, K.D.A.; Arndt, J.O.

    1987-01-01

    The authors studied the effects of dihydroergotamine (DHE) and etilefrine hydrochloride (E) on the regional distribution of /sup 99m/Tc-marked erythrocytes during epidural anesthesia in eight supine men to determine if vasoactive agents with venoconstrictor action would enhance cardiac filling during epidural anesthesia. Radioactivity was recorded with a gamma camera, and its distribution determined in the thorax, abdomen, and limbs. Arterial and central venous pressure, heart rate, and calf volume by plethysmography were measured. During epidural anesthesia with a sensory block up to T4/5, DHE (7.5 micrograms/kg) reduced the radioactivity, i.e., blood volume, in both the innervated (-5.9 +/- 3.5%) and denervated muscle/skin (-16.9 +/- 7%) regions, and increased it in both the intrathoracic (+7.0 +/- 2.3%), and splanchnic vasculature (+4.2 +/- 3.2). In contrast, E (6 micrograms X kg-1 X min-1) decreased the blood volume most markedly in the splanchnic region (-5.4 +/- 0.7%) and increased it in the thorax (+2 +/- 0.6%). All these changes were statistically significant. The combined effects were estimated to be equivalent to a transfusion of nearly 1.01 of blood. Both drugs reversed the hypotensive action of epidural anesthesia. During epidural anesthesia, DHE preferentially constricted the capacitance vessels in skeletal muscle and skin irrespective of the state of innervation, whereas E preferentially constricted the splanchnic vasculature. In the doses used, the two agents replenished in an additive fashion the central circulation during epidural anesthesia

  19. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer semi-constrained cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3350 Hip joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  20. Of Human Bodies in Scientific Communication and Enculturation

    Science.gov (United States)

    Hwang, SungWon; Roth, Wolff-Michael

    2008-01-01

    How do students become enculturated and come to enact culture in ways that are new to them? This study probes the dialectical processes of enculturation, the central aspect of which is the role of human bodies in communication. For students, as for any individual, culture exists in terms of action possibilities that presuppose their…

  1. Accidental aspiration/ingestion of foreign bodies in dentistry: A clinical and legal perspective

    Science.gov (United States)

    Yadav, Rakesh Kumar; Yadav, Hemant Kumar; Chandra, Anil; Yadav, Simith; Verma, Promila; Shakya, Vijay Kumar

    2015-01-01

    The potential of foreign body aspiration or ingestion is a worldwide health problem in dentistry. The general dental practitioners should be extremely attentive in handling of minor instruments during any intervention related to the oral cavity, especially in the supine or semi-recumbent position of the patient. Aspiration cases are usually more critical and less common than ingestion. We report a case of iatrogenic aspiration of an endodontic broach, which gets disclosed during the recording of past dental history of the patient. The patient was asymptomatic during that time. A quick posterior-anterior chest radiograph was taken which revealed the presence of broach in the lower lobe of the left lung. The patient was immediately referred to the pulmonary medicine department where the fiberoptic bronchoscope retrieval was planned, and the same was carried out successfully under local anesthesia. Although such accidents have rare occurrence, the associated risks and morbidity are too high to be overlooked, especially from the viewpoint of special care, resources, and the associated financial cost required for their management. Moreover, practitioners are also liable for malpractice litigation given the fact that such cases are avoidable. This article also discusses relevant review literature, risk factors, symptoms, and management of such iatrogenic accidents along with drawing attention to the significance of preventive measures and their role in avoiding meritorious legal and ethical issues. PMID:27390487

  2. Host genetic variation impacts microbiome composition across human body sites.

    Science.gov (United States)

    Blekhman, Ran; Goodrich, Julia K; Huang, Katherine; Sun, Qi; Bukowski, Robert; Bell, Jordana T; Spector, Timothy D; Keinan, Alon; Ley, Ruth E; Gevers, Dirk; Clark, Andrew G

    2015-09-15

    The composition of bacteria in and on the human body varies widely across human individuals, and has been associated with multiple health conditions. While microbial communities are influenced by environmental factors, some degree of genetic influence of the host on the microbiome is also expected. This study is part of an expanding effort to comprehensively profile the interactions between human genetic variation and the composition of this microbial ecosystem on a genome- and microbiome-wide scale. Here, we jointly analyze the composition of the human microbiome and host genetic variation. By mining the shotgun metagenomic data from the Human Microbiome Project for host DNA reads, we gathered information on host genetic variation for 93 individuals for whom bacterial abundance data are also available. Using this dataset, we identify significant associations between host genetic variation and microbiome composition in 10 of the 15 body sites tested. These associations are driven by host genetic variation in immunity-related pathways, and are especially enriched in host genes that have been previously associated with microbiome-related complex diseases, such as inflammatory bowel disease and obesity-related disorders. Lastly, we show that host genomic regions associated with the microbiome have high levels of genetic differentiation among human populations, possibly indicating host genomic adaptation to environment-specific microbiomes. Our results highlight the role of host genetic variation in shaping the composition of the human microbiome, and provide a starting point toward understanding the complex interaction between human genetics and the microbiome in the context of human evolution and disease.

  3. Effect of Temperature-Sensitive Poloxamer Solution/Gel Material on Pericardial Adhesion Prevention: Supine Rabbit Model Study Mimicking Cardiac Surgery.

    Directory of Open Access Journals (Sweden)

    Hyun Kang

    Full Text Available We investigated the mobility of a temperature-sensitive poloxamer/Alginate/CaCl2 mixture (PACM in relation to gravity and cardiac motion and the efficacy of PACM on the prevention of pericardial adhesion in a supine rabbit model.A total of 50 rabbits were randomly divided into two groups according to materials applied after epicardial abrasion: PACM and dye mixture (group PD; n = 25 and saline as the control group (group CO; n = 25. In group PD, rabbits were maintained in a supine position with appropriate sedation, and location of mixture of PACM and dye was assessed by CT scan at the immediate postoperative period and 12 hours after surgery. The grade of adhesions was evaluated macroscopically and microscopically two weeks after surgery.In group PD, enhancement was localized in the anterior pericardial space, where PACM and dye mixture was applied, on immediate post-surgical CT scans. However, the volume of the enhancement was significantly decreased at the anterior pericardial space 12 hours later (P < .001. Two weeks after surgery, group PD had significantly lower macroscopic adhesion score (P = .002 and fibrosis score (P = .018 than did group CO. Inflammation score and expression of anti-macrophage antibody in group PD were lower than those in group CO, although the differences were not significant.In a supine rabbit model study, the anti-adhesion effect was maintained at the area of PACM application, although PACM shifted with gravity and heart motion. For more potent pericardial adhesion prevention, further research and development on the maintenance of anti-adhesion material position are required.

  4. Age-related differences in the response of leg muscle cross-sectional area and water diffusivity measures to a period of supine rest.

    Science.gov (United States)

    Lorbergs, Amanda L; Noseworthy, Michael D; MacIntyre, Norma J

    2015-06-01

    The object was to assess whether cross-sectional area (CSA) and water diffusion properties of leg muscles in young and older women change with increased time spent in supine rest. Healthy young (n = 9, aged 20-30 years) and older (n = 9, aged 65-75 years) women underwent MRI scanning of the right leg at baseline, 30 and 60 min of supine rest. Muscle CSA was derived from proton density images. Water diffusion properties [apparent diffusion coefficient (ADC) and fractional anisotropy (FA)] of the tibialis anterior and posterior, soleus, and medial and lateral heads of the gastrocnemius were derived from diffusion tensor imaging (DTI). Repeated measures ANOVAs and Bonferroni post hoc tests determined the effects of time and group on each muscle outcome. In both groups, muscle CSA and FA did not significantly change over time, whereas ADC significantly decreased. A greater decline at 30 min for young women was only observed for ADC in the medial gastrocnemius. Regardless of age, ADC values decreased with fluid shift associated with time spent supine, whereas CSA and FA were not affected. For leg muscle assessment in young and older women, DTI scanning protocols should consider the amount of time spent in a recumbent position.

  5. What Bed Size Does a Patient Need? The Relationship Between Body Mass Index and Space Required to Turn in Bed.

    Science.gov (United States)

    Wiggermann, Neal; Smith, Kathryn; Kumpar, Dee

    A bed that is too small to allow patients to turn from supine to side lying increases the difficulty of mobilizing patients, which can increase risk of musculoskeletal injury to caregivers, increase risk of pressure injuries to patients, and reduce patient comfort. Currently, no guidance is available for what patient sizes are accommodated by the standard 91cm (36 in.)-wide hospital bed, and no studies have evaluated the relationship between anthropometric attributes and space required to turn in bed. The purpose of this research was to determine how much space individuals occupy when turning from supine to side lying as predicted by their anthropometry (i.e., body dimensions) to establish guidance on selecting the appropriate bed size. Forty-seven adult participants (24 female) with body mass index (BMI) from 20 to 76 kg/m participated in a laboratory study. Body dimensions were measured, and the envelope of space required to turn was determined using motion capture. Linear regressions estimated the relationship between anthropometric attributes and space occupied when turning. BMI was strongly correlated (R = .88) with the space required to turn. Based on the linear regressions, individuals with BMI up to 35 kg/m could turn left and right within 91 cm and individuals with BMI up to 45 kg/m could turn one direction within 91 cm. BMI is a good predictor of the space required to turn from supine to lateral. Nurses should consider placing patients that are unable to laterally reposition themselves on a wider bed when BMI is greater than 35 kg/m and should consider placing all patients greater than 45 kg/m on a wider bed regardless of mobility. Hospital administrators can use historical demographic information about the BMI of their patient populations to plan facility-level equipment procurement for equipment that accommodates their patients.

  6. Verification techniques and dose distribution for computed tomographic planned supine craniospinal radiation therapy

    International Nuclear Information System (INIS)

    Chang, Eric L.; Wong Peifong; Forster, Kenneth M.; Petru, Mark D.; Kowalski, Alexander V.; Maor, Moshe H.

    2003-01-01

    A modified 3-field technique was designed with opposed cranial fields and a single spinal field encompassing the entire spinal axis. Two methods of plan verifications were performed before the first treatment. First, a system of orthogonal rulers plus the thermoplastic head holder was used to visualize the light fields at the craniospinal junction. Second, film phantom measurements were taken to visualize the gap between the fields at the level of the spinal cord. Treatment verification entailed use of a posterior-anterior (PA) portal film and placement of radiopaque wire on the inferior border of the cranial field. More rigorous verification required a custom-fabricated orthogonal film holder. The isocenter positions of both fields when they matched were recorded using a record-and-verify system. A single extended distance spinal field collimated at 42 degree sign encompassed the entire spinal neuraxis. Data were collected from 40 fractions of craniospinal irradiation (CSI). The systematic error observed for the actual daily treatments was -0.5 mm (underlap), while the stochastic error was represented by a standard deviation of 5.39 mm. Measured data across the gapped craniospinal junction with junction shifts included revealed a dose ranging from 89.3% to 108%. CSI can be performed without direct visualization of the craniospinal junction by using the verification methods described. While the use of rigorous film verification for supine technique may have reduced the systematic error, the inability to visualize the supine craniospinal junction on skin appears to have increased the stochastic error compared to published data on such errors associated with prone craniospinal irradiation

  7. Cervical spine trauma radiographs: Swimmers and supine obliques; an exploration of current practice

    Energy Technology Data Exchange (ETDEWEB)

    Fell, Michael, E-mail: michael.fell@mkgeneral.nhs.u [Milton Keynes General Hospital, Radiology Standing Way, Eaglestone, Milton Keynes, Buckinghamshire MK6 5LD (United Kingdom)

    2011-02-15

    The study objectives were: to investigate current cervical spine radiographic imaging practices in conscious adult patients with suspected neck injury; reasons behind variation and consideration of dose estimates were explored. Comparison with a previous survey has been made. Questionnaires were sent to superintendent radiographers responsible for accident and emergency X-ray departments in English trusts with over 8500 emergency admissions per year, with a response rate of 97% (n = 181/186). Departmental cervical spine imaging protocols were reported by 82% of respondents. None use fewer than the three standard projections; if the cervicothoracic junction (C7/T1), is not adequately demonstrated 87% use swimmers projections, 9% supine obliques, 3% CT alone. Following projectional radiography, 97% perform CT. A significant (p = 0.018) increase was found since 1999 in CT use once the swimmers projection fails; fewer now use obliques at this point, continuing with CT instead. No significant difference (p = 0.644) was found in choice of first supplementary radiographs; despite British Trauma Society's recommendation to undertake supine obliques, swimmers remain the most widespread technique. An 85% response rate (n = 103/121) completed a second questionnaire, exploring reasons behind the various practices. Several reported a perceived difficulty in interpreting oblique radiographs, some a concern over high dose of the swimmers. Numerous issues affect the acquisition of cervical spine radiographs. Patient radiation dose should be a major consideration in selection of technique. A potential need for training in interpretation of obliques is highlighted. Specific guidelines for optimum projections should be researched, and protocols issued to ensure best practice.

  8. Local cooling of the human body using ventilated matress in hospitals

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Kokora, Monika

    2014-01-01

    A series of experiments were conducted in order to examine the cooling of the human body in bed equipped with a ventilated mattress (VM). The experiments were performed in a climate chamber (4.65 m width x 5.3 m length x 2.6 m height) which was air-conditioned by mixing ventilation system...... temperature or by use of natural ventilation. However the non-uniform body cooling may cause local thermal discomfort. This needs to be further studied in human subject experiments......., 26 and 30 oC. The performance of the VM was tested when VM was operating at different air flow rates (1.5, 3, 4.5 and 6 L/s). The impact of body covering on the cooling effect from the VM was also studied. The performance of the cooling method was evaluated based on comparison of the segmental...

  9. Safety issues associated with the use of nanoparticles in human body.

    Science.gov (United States)

    Sufian, Mian Muhammad; Khattak, Jabar Zaman Khan; Yousaf, Shahzad; Rana, Muhammad Suleman

    2017-09-01

    Nanotechnology has transformed the world by the introduction of a distinctive class of materials and products in a wide array of fields. It has contributed to the production of innovative materials and devices. Having unique advantages and domestic along with industrial applications, however, has raised the issue of safety for consumers, producers and environment. Having a comparative smaller dimension and other exclusive properties, nanoparticles have the ability to harm human body by interacting through various mechanisms. Here, we endeavoured to review and discuss the characteristics of nanoparticles relevant to their toxicity, conceivable exposure routes of nanoparticles to human body like skin contact, inhalation, and ingestion, and the basic approaches which can aid to control human exposures to toxic nanoparticles have been discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Micromechanics of the human vertebral body for forward flexion.

    Science.gov (United States)

    Yang, Haisheng; Nawathe, Shashank; Fields, Aaron J; Keaveny, Tony M

    2012-08-09

    To provide mechanistic insight into the etiology of osteoporotic wedge fractures, we investigated the spatial distribution of tissue at the highest risk of initial failure within the human vertebral body for both forward flexion and uniform compression loading conditions. Micro-CT-based linear elastic finite element analysis was used to virtually load 22 human T9 vertebral bodies in either 5° of forward flexion or uniform compression; we also ran analyses replacing the simulated compliant disc (E=8 MPa) with stiff polymethylmethacrylate (PMMA, E=2500 MPa). As expected, we found that, compared to uniform compression, forward flexion increased the overall endplate axial load on the anterior half of the vertebra and shifted the spatial distribution of high-risk tissue within the vertebra towards the anterior aspect of the vertebral body. However, despite that shift, the high-risk tissue remained primarily within the central regions of the trabecular bone and endplates, and forward flexion only slightly altered the ratio of cortical-to-trabecular load sharing at the mid-vertebral level (mean±SD for n=22: 41.3±7.4% compression; 44.1±8.2% forward flexion). When the compliant disc was replaced with PMMA, the anterior shift of high-risk tissue was much more severe. We conclude that, for a compliant disc, a moderate degree of forward flexion does not appreciably alter the spatial distribution of stress within the vertebral body. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Effect of the Environmental Stimuli upon the Human Body in Winter Outdoor Thermal Environment

    Directory of Open Access Journals (Sweden)

    Yoshihito Kurazumi

    2013-01-01

    Full Text Available In order to manage the outdoor thermal environment with regard to human health and the environmental impact of waste heat, quantitative evaluations are indispensable. It is necessary to use a thermal environment evaluation index. The purpose of this paper is to clarify the relationship between the psychological thermal responses of the human body and winter outdoor thermal environment variables. Subjective experiments were conducted in the winter outdoor environment. Environmental factors and human psychological responses were measured. The relationship between the psychological thermal responses of the human body and the outdoor thermal environment index ETFe (enhanced conduction-corrected modified effective temperature in winter was shown. The variables which influence the thermal sensation vote of the human body are air temperature, long-wave thermal radiation and short-wave solar radiation. The variables that influence the thermal comfort vote of the human body are air temperature, humidity, short-wave solar radiation, long-wave thermal radiation, and heat conduction. Short-wave solar radiation, and heat conduction are among the winter outdoor thermal environment variables that affect psychological responses to heat. The use of thermal environment evaluation indices that comprise short-wave solar radiation and heat conduction in winter outdoor spaces is a valid approach.

  12. Effect of the Environmental Stimuli upon the Human Body in Winter Outdoor Thermal Environment

    Science.gov (United States)

    Kurazumi, Yoshihito; Kondo, Emi; Ishii, Jin; Sakoi, Tomonori; Fukagawa, Kenta; Bolashikov, Zhecho Dimitrov; Tsuchikawa, Tadahiro; Matsubara, Naoki; Horikoshi, Tetsumi

    2013-01-01

    In order to manage the outdoor thermal environment with regard to human health and the environmental impact of waste heat, quantitative evaluations are indispensable. It is necessary to use a thermal environment evaluation index. The purpose of this paper is to clarify the relationship between the psychological thermal responses of the human body and winter outdoor thermal environment variables. Subjective experiments were conducted in the winter outdoor environment. Environmental factors and human psychological responses were measured. The relationship between the psychological thermal responses of the human body and the outdoor thermal environment index ETFe (enhanced conduction-corrected modified effective temperature) in winter was shown. The variables which influence the thermal sensation vote of the human body are air temperature, long-wave thermal radiation and short-wave solar radiation. The variables that influence the thermal comfort vote of the human body are air temperature, humidity, short-wave solar radiation, long-wave thermal radiation, and heat conduction. Short-wave solar radiation, and heat conduction are among the winter outdoor thermal environment variables that affect psychological responses to heat. The use of thermal environment evaluation indices that comprise short-wave solar radiation and heat conduction in winter outdoor spaces is a valid approach. PMID:23861691

  13. Ionizing radiation and lipid peroxidation in human body

    International Nuclear Information System (INIS)

    Giubileo, Gianfranco

    1997-07-01

    Lipids are organic compounds constituting the living cells. Lipid molecules can be disassembled through peroxidative pathways and hydrocarbons can be bred as end-product of lipid peroxidation in vivo. Lipid peroxidation can be started by an indirect effect of ionizing radiation. So a radioinduced cellular damage in human body can be detected by monitoring the production of specific hydrocarbons

  14. Semi-manual mastoidectomy assisted by human-robot collaborative control - A temporal bone replica study.

    Science.gov (United States)

    Lim, Hoon; Matsumoto, Nozomu; Cho, Byunghyun; Hong, Jaesung; Yamashita, Makoto; Hashizume, Makoto; Yi, Byung-Ju

    2016-04-01

    To develop an otological robot that can protect important organs from being injured. We developed a five degree-of-freedom robot for otological surgery. Unlike the other robots that were reported previously, our robot does not replace surgeon's procedures, but instead utilizes human-robot collaborative control. The robot basically releases all of the actuators so that the surgeon can manipulate the drill within the robot's working area with minimal restriction. When the drill reaches a forbidden area, the surgeon feels as if the drill hits a wall. When an engineer performed mastoidectomy using the robot for assistance, the facial nerve in the segmented region was always protected with a more than 2.5mm margin, which was almost the same as the pre-set safety margin of 3mm. Semi-manual drilling using human-robot collaborative control was feasible, and may hold a realistic prospect of clinical use in the near future. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Coming to Know about the Body in Human Movement Studies Programmes

    Science.gov (United States)

    Varea, Valeria; Tinning, Richard

    2016-01-01

    This paper explores how a group of undergraduate Human Movement Studies (HMS) students learnt to know about the body during their four-year academic programme at an Australian university. When students begin an undergraduate programme in HMS they bring with them particular constructions, ideas and beliefs about their own bodies and about the body…

  16. A relation between calculated human body exergy consumption rate and subjectively assessed thermal sensation

    Energy Technology Data Exchange (ETDEWEB)

    Simone, Angela; Kolarik, Jakub; Olesen, Bjarne W. [ICIEE/BYG, Technical University of Denmark (Denmark); Iwamatsu, Toshiya [Faculty of Urban Environmental Science, Tokyo Metropolitan University (Japan); Asada, Hideo [Architech Consulting Co., Tokyo (Japan); Dovjak, Mateja [Faculty of Civil and Geodetic Engineering, University of Ljubljana (Slovenia); Schellen, Lisje [Eindhoven University of Technology, Faculty of Architecture Building and Planning (Netherlands); Shukuya, Masanori [Laboratory of Building Environment, Tokyo City University, Yokohama (Japan)

    2011-01-15

    Application of the exergy concept to research on the built environment is a relatively new approach. It helps to optimize climate conditioning systems so that they meet the requirements of sustainable building design. As the building should provide a healthy and comfortable environment for its occupants, it is reasonable to consider both the exergy flows in building and those within the human body. Until now, no data have been available on the relation between human-body exergy consumption rates and subjectively assessed thermal sensation. The objective of the present work was to relate thermal sensation data, from earlier thermal comfort studies, to calculated human-body exergy consumption rates. The results show that the minimum human body exergy consumption rate is associated with thermal sensation votes close to thermal neutrality, tending to the slightly cool side of thermal sensation. Generally, the relationship between air temperature and the exergy consumption rate, as a first approximation, shows an increasing trend. Taking account of both convective and radiative heat exchange between the human body and the surrounding environment by using the calculated operative temperature, exergy consumption rates increase as the operative temperature increases above 24 C or decreases below 22 C. With the data available so far, a second-order polynomial relationship between thermal sensation and the exergy consumption rate was established. (author)

  17. Numerical simulation of thermal behaviors of a clothed human body with evaluation of indoor solar radiation

    International Nuclear Information System (INIS)

    Mao, Aihua; Luo, Jie; Li, Yi

    2017-01-01

    Highlights: • Solar radiation evaluation is integrated with the thermal transfer in clothed humans. • Thermal models are developed for clothed humans exposed in indoor solar radiation. • The effect of indoor solar radiation on humans can be predicted in different situations in living. • The green solar energy can be efficiently utilized in the building development. - Abstract: Solar radiation is a valuable green energy, which is important in achieving a successful building design for thermal comfort in indoor environment. This paper considers solar radiation indoors into the transient thermal transfer models of a clothed human body and offers a new numerical method to analyze the dynamic thermal status of a clothed human body under different solar radiation incidences. The evaluation model of solar radiation indoors and a group of coupled thermal models of the clothed human body are developed and integrated. The simulation capacities of these integrated models are validated through a comparison between the predicted results and the experimental data in reference. After that, simulation cases are also conducted to show the influence of solar radiation on the thermal status of individual clothed body segments when the human body is staying indoors in different seasons. This numerical simulation method provides a useful tool to analyze the thermal status of clothed human body under different solar radiation incidences indoors and thus enables the architect to efficiently utilize the green solar energy in building development.

  18. Review on modeling heat transfer and thermoregulatory responses in human body.

    Science.gov (United States)

    Fu, Ming; Weng, Wenguo; Chen, Weiwang; Luo, Na

    2016-12-01

    Several mathematical models of human thermoregulation have been developed, contributing to a deep understanding of thermal responses in different thermal conditions and applications. In these models, the human body is represented by two interacting systems of thermoregulation: the controlling active system and the controlled passive system. This paper reviews the recent research of human thermoregulation models. The accuracy and scope of the thermal models are improved, for the consideration of individual differences, integration to clothing models, exposure to cold and hot conditions, and the changes of physiological responses for the elders. The experimental validated methods for human subjects and manikin are compared. The coupled method is provided for the manikin, controlled by the thermal model as an active system. Computational Fluid Dynamics (CFD) is also used along with the manikin or/and the thermal model, to evaluate the thermal responses of human body in various applications, such as evaluation of thermal comfort to increase the energy efficiency, prediction of tolerance limits and thermal acceptability exposed to hostile environments, indoor air quality assessment in the car and aerospace industry, and design protective equipment to improve function of the human activities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Ideas about the Human Body among Secondary Students in South Africa

    Science.gov (United States)

    Granklint Enochson, Pernilla; Redfors, Andreas; Dempster, Edith R.; Tibell, Lena A. E.

    2015-01-01

    In this paper we focus on how South African students' ideas about the human body are constituted in their descriptions of three different scenarios involving the pathway of a sandwich, a painkiller and a glass of water through the body. In particular, we have studied the way in which the students transferred ideas between the sandwich and the…

  20. [Human body meridian spatial decision support system for clinical treatment and teaching of acupuncture and moxibustion].

    Science.gov (United States)

    Wu, Dehua

    2016-01-01

    The spatial position and distribution of human body meridian are expressed limitedly in the decision support system (DSS) of acupuncture and moxibustion at present, which leads to the failure to give the effective quantitative analysis on the spatial range and the difficulty for the decision-maker to provide a realistic spatial decision environment. Focusing on the limit spatial expression in DSS of acupuncture and moxibustion, it was proposed that on the basis of the geographic information system, in association of DSS technology, the design idea was developed on the human body meridian spatial DSS. With the 4-layer service-oriented architecture adopted, the data center integrated development platform was taken as the system development environment. The hierarchical organization was done for the spatial data of human body meridian via the directory tree. The structured query language (SQL) server was used to achieve the unified management of spatial data and attribute data. The technologies of architecture, configuration and plug-in development model were integrated to achieve the data inquiry, buffer analysis and program evaluation of the human body meridian spatial DSS. The research results show that the human body meridian spatial DSS could reflect realistically the spatial characteristics of the spatial position and distribution of human body meridian and met the constantly changeable demand of users. It has the powerful spatial analysis function and assists with the scientific decision in clinical treatment and teaching of acupuncture and moxibustion. It is the new attempt to the informatization research of human body meridian.

  1. The personification of animals: coding of human and nonhuman body parts based on posture and function.

    Science.gov (United States)

    Welsh, Timothy N; McDougall, Laura; Paulson, Stephanie

    2014-09-01

    The purpose of the present research was to determine how humans represent the bodies and limbs of nonhuman mammals based on anatomical and functional properties. To this end, participants completed a series of body-part compatibility tasks in which they responded with a thumb or foot response to the color of a stimulus (red or blue, respectively) presented on different limbs of several animals. Across the studies, this compatibility task was conducted with images of human and nonhuman animals (bears, cows, and monkeys) in bipedal or quadrupedal postures. The results revealed that the coding of the limbs of nonhuman animals is strongly influenced by the posture of the body, but not the functional capacity of the limb. Specifically, body-part compatibility effects were present for both human and nonhuman animals when the figures were in a bipedal posture, but were not present when the animals were in a quadrupedal stance (Experiments 1a-c). Experiments 2a and 2b revealed that the posture-based body-part compatibility effects were not simply a vertical spatial compatibility effect or due to a mismatch between the posture of the body in the image and the participant. These data indicate that nonhuman animals in a bipedal posture are coded with respect to the "human" body representation, whereas nonhuman animals in a quadrupedal posture are not mapped to the human body representation. Overall, these studies provide new insight into the processes through which humans understand, mimic, and learn from the actions of nonhuman animals. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Dynamics and associations of microbial community types across the human body.

    Science.gov (United States)

    Ding, Tao; Schloss, Patrick D

    2014-05-15

    A primary goal of the Human Microbiome Project (HMP) was to provide a reference collection of 16S ribosomal RNA gene sequences collected from sites across the human body that would allow microbiologists to better associate changes in the microbiome with changes in health. The HMP Consortium has reported the structure and function of the human microbiome in 300 healthy adults at 18 body sites from a single time point. Using additional data collected over the course of 12-18 months, we used Dirichlet multinomial mixture models to partition the data into community types for each body site and made three important observations. First, there were strong associations between whether individuals had been breastfed as an infant, their gender, and their level of education with their community types at several body sites. Second, although the specific taxonomic compositions of the oral and gut microbiomes were different, the community types observed at these sites were predictive of each other. Finally, over the course of the sampling period, the community types from sites within the oral cavity were the least stable, whereas those in the vagina and gut were the most stable. Our results demonstrate that even with the considerable intra- and interpersonal variation in the human microbiome, this variation can be partitioned into community types that are predictive of each other and are probably the result of life-history characteristics. Understanding the diversity of community types and the mechanisms that result in an individual having a particular type or changing types, will allow us to use their community types to assess disease risk and to personalize therapies.

  3. A systematic review of the human body burden of e-waste exposure in China.

    Science.gov (United States)

    Song, Qingbin; Li, Jinhui

    2014-07-01

    As China is one of the countries facing the most serious pollution and human exposure effects of e-waste in the world, much of the population there is exposed to potentially hazardous substances due to informal e-waste recycling processes. This report reviews recent studies on human exposure to e-waste in China, with particular focus on exposure routes (e.g. dietary intake, inhalation, and soil/dust ingestion) and human body burden markers (e.g. placenta, umbilical cord blood, breast milk, blood, hair, and urine) and assesses the evidence for the association between such e-waste exposure and the human body burden in China. The results suggest that residents in the e-waste exposure areas, located mainly in the three traditional e-waste recycling sites (Taizhou, Guiyu, and Qingyuan), are faced with a potential higher daily intake of these pollutants than residents in the control areas, especially via food ingestion. Moreover, pollutants (PBBs, PBDEs, PCBs, PCDD/Fs, and heavy metals) from the e-waste recycling processes were all detectable in the tissue samples at high levels, showing that they had entered residents' bodies through the environment and dietary exposure. Children and neonates are the groups most sensitive to the human body effects of e-waste exposure. We also recorded plausible outcomes associated with exposure to e-waste, including 7 types of human body burden. Although the data suggest that exposure to e-waste is harmful to health, better designed epidemiological investigations in vulnerable populations, especially neonates and children, are needed to confirm these associations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  5. Robotic Missions to Small Bodies and Their Potential Contributions to Human Exploration and Planetary Defense

    Science.gov (United States)

    Abell, Paul A.; Rivkin, Andrew S.

    2015-01-01

    Introduction: Robotic missions to small bodies will directly address aspects of NASA's Asteroid Initiative and will contribute to future human exploration and planetary defense. The NASA Asteroid Initiative is comprised of two major components: the Grand Challenge and the Asteroid Mission. The first component, the Grand Challenge, focuses on protecting Earth's population from asteroid impacts by detecting potentially hazardous objects with enough warning time to either prevent them from impacting the planet, or to implement civil defense procedures. The Asteroid Mission involves sending astronauts to study and sample a near-Earth asteroid (NEA) prior to conducting exploration missions of the Martian system, which includes Phobos and Deimos. The science and technical data obtained from robotic precursor missions that investigate the surface and interior physical characteristics of an object will help identify the pertinent physical properties that will maximize operational efficiency and reduce mission risk for both robotic assets and crew operating in close proximity to, or at the surface of, a small body. These data will help fill crucial strategic knowledge gaps (SKGs) concerning asteroid physical characteristics that are relevant for human exploration considerations at similar small body destinations. These data can also be applied for gaining an understanding of pertinent small body physical characteristics that would also be beneficial for formulating future impact mitigation procedures. Small Body Strategic Knowledge Gaps: For the past several years NASA has been interested in identifying the key SKGs related to future human destinations. These SKGs highlight the various unknowns and/or data gaps of targets that the science and engineering communities would like to have filled in prior to committing crews to explore the Solar System. An action team from the Small Bodies Assessment Group (SBAG) was formed specifically to identify the small body SKGs under the

  6. Genetics of human body size and shape: body proportions and indices.

    Science.gov (United States)

    Livshits, Gregory; Roset, A; Yakovenko, K; Trofimov, S; Kobyliansky, E

    2002-01-01

    environmental effects were also detectable. Genetic factors substantially influence inter-individual differences in body shape and configuration in two studied samples. However, further studies are needed to clarify the extent of pleiotropy and epigenetic effects on various facets of the human physique.

  7. Unsteady-state human-body exergy consumption rate and its relation to subjective assessment of dynamic thermal environments

    DEFF Research Database (Denmark)

    Schweiker, Marcel; Kolarik, Jakub; Dovjak, Mateja

    2016-01-01

    of the present study confirmed previously indicated trends that lowest human body exergy consumption rate is associated with thermal sensation close to neutrality. Moreover, higher acceptability was in general associated with lower human body exergy consumption rate. (C) 2016 Elsevier B.V. All rights reserved.......Few examples studied applicability of exergy analysis on human thermal comfort. These examples relate the human-body exergy consumption rate with subjectively obtained thermal sensation votes and had been based on steady-state calculation methods. However, humans are rarely exposed to steady...... between the human-body exergy consumption rate and subjective assessment of thermal environment represented by thermal sensation as well as to extend the investigation towards thermal acceptability votes. Comparison of steady-state and unsteady-state model showed that results from both models were...

  8. On the dynamics of a human body model.

    Science.gov (United States)

    Huston, R. L.; Passerello, C. E.

    1971-01-01

    Equations of motion for a model of the human body are developed. Basically, the model consists of an elliptical cylinder representing the torso, together with a system of frustrums of elliptical cones representing the limbs. They are connected to the main body and each other by hinges and ball and socket joints. Vector, tensor, and matrix methods provide a systematic organization of the geometry. The equations of motion are developed from the principles of classical mechanics. The solution of these equations then provide the displacement and rotation of the main body when the external forces and relative limb motions are specified. Three simple example motions are studied to illustrate the method. The first is an analysis and comparison of simple lifting on the earth and the moon. The second is an elementary approach to underwater swimming, including both viscous and inertia effects. The third is an analysis of kicking motion and its effect upon a vertically suspended man such as a parachutist.

  9. Force direction patterns promote whole body stability even in hip-flexed walking, but not upper body stability in human upright walking

    Science.gov (United States)

    Müller, Roy; Rode, Christian; Aminiaghdam, Soran; Vielemeyer, Johanna; Blickhan, Reinhard

    2017-11-01

    Directing the ground reaction forces to a focal point above the centre of mass of the whole body promotes whole body stability in human and animal gaits similar to a physical pendulum. Here we show that this is the case in human hip-flexed walking as well. For all upper body orientations (upright, 25°, 50°, maximum), the focal point was well above the centre of mass of the whole body, suggesting its general relevance for walking. Deviations of the forces' lines of action from the focal point increased with upper body inclination from 25 to 43 mm root mean square deviation (RMSD). With respect to the upper body in upright gait, the resulting force also passed near a focal point (17 mm RMSD between the net forces' lines of action and focal point), but this point was 18 cm below its centre of mass. While this behaviour mimics an unstable inverted pendulum, it leads to resulting torques of alternating sign in accordance with periodic upper body motion and probably provides for low metabolic cost of upright gait by keeping hip torques small. Stabilization of the upper body is a consequence of other mechanisms, e.g. hip reflexes or muscle preflexes.

  10. Interactive effect of body posture on exercise-induced atrial natriuretic peptide release.

    Science.gov (United States)

    Ray, C A; Delp, M D; Hartle, D K

    1990-05-01

    The purpose of this investigation was to test the hypothesis that supine exercise elicits a greater atrial natriuretic peptide (ANP) response than upright exercise because of higher atrial filling pressure attained in the supine posture. Plasma ANP concentration ([ANP]) was measured during continuous graded supine and upright exercise in eight healthy men at rest after 4 min of cycling exercise at 31, 51, and 79% of posture-specific peak oxygen uptake (VO2 peak), after 2 min of cycling at posture-specific VO2 peak, and 5 and 15 min postexercise. [ANP] was significantly increased (P less than 0.05) above rest by 64, 140, and 228% during supine cycling at 51 and 79% and VO2 peak, respectively. During upright cycling, [ANP] was significantly increased (P less than 0.05) at 79% (60%) and VO2 peak (125%). After 15 min of postexercise rest, [ANP] remained elevated (P less than 0.05) only in the supine subjects. [ANP] was 63, 79, and 75% higher (P less than 0.05) in the supine than in the upright position during cycling at 51 and 79% and VO2 peak. Systolic, diastolic, and mean blood pressures were not significantly (P greater than 0.05) different between positions in all measurement periods. Heart rates were lower (P less than 0.05) in the supine position compared with the upright position. In conclusion, these results suggest that supine exercise elicits greater ANP release independent of blood pressure and heart rate but presumably caused by greater venous return, central blood volume, and concomitant atrial filling pressure and stretch.

  11. Supination external rotation ankle fractures: A simpler pattern with better outcomes

    Science.gov (United States)

    Tejwani, Nirmal C; Park, Ji Hae; Egol, Kenneth A

    2015-01-01

    Background: Rotational injuries are the most common and usually classified as per the Lauge Hansen classification; with the most common subgroup being the supination external rotation (SER) mechanism. Isolated fractures of the distal fibula (SE2) without associated ligamentous injury are usually treated with a splint or brace and the patient may be allowed to weight bear as tolerated. This study reports the functional outcomes following a stable, low energy, rotational ankle fracture supination external rotation (SER2) when compared to unstable SER4 fractures treated operatively. Materials and Methods: 64 patients who were diagnosed and treated nonoperatively for a stable SER2 ankle fracture were followed prospectively. In the comparison group, 93 operatively treated fibular fractures were extracted from a prospectively collected database and evaluated comparison. Baseline characteristics obtained by trained interviewers at the time of injury included: Patient demographics, short form-36, short musculoskeletal functional assessment (SMFA) and American Orthopedic Foot and Ankle Society (AOFAS) questionnaires. Patients were followed at 3, 6 and 12 months postsurgery. Additional information obtained at each followup point included any complications or evidence on fracture healing. Data were analyzed by the Student's t-test and theFisher's Exact Test to compare demographic and functional outcomes between the two cohorts. P fracture cohort was 43 versus 45 in the SER4 group. Nearly 64% of the patient population was female when compared with 37% in the operative group. In the SER2 by 6 months all patients had returned to baseline functional status. There were 18 delayed unions (all healed by 6 months). Based on the functional outcome scores all patients had returned to preoperative level. In comparison, SE4 patients had less functional recovery at 3 and 6 months (P delayed unions. Conclusions: An SER2 ankle fracture is a relatively benign injury with functional

  12. Active numerical model of human body for reconstruction of falls from height.

    Science.gov (United States)

    Milanowicz, Marcin; Kędzior, Krzysztof

    2017-01-01

    Falls from height constitute the largest group of incidents out of approximately 90,000 occupational accidents occurring each year in Poland. Reconstruction of the exact course of a fall from height is generally difficult due to lack of sufficient information from the accident scene. This usually results in several contradictory versions of an incident and impedes, for example, determination of the liability in a judicial process. In similar situations, in many areas of human activity, researchers apply numerical simulation. They use it to model physical phenomena to reconstruct their real course over time; e.g. numerical human body models are frequently used for investigation and reconstruction of road accidents. However, they are validated in terms of specific road traffic accidents and are considerably limited when applied to the reconstruction of other types of accidents. The objective of the study was to develop an active numerical human body model to be used for reconstruction of accidents associated with falling from height. Development of the model involved extension and adaptation of the existing Pedestrian human body model (available in the MADYMO package database) for the purposes of reconstruction of falls from height by taking into account the human reaction to the loss of balance. The model was developed by using the results of experimental tests of the initial phase of the fall from height. The active numerical human body model covering 28 sets of initial conditions related to various human reactions to the loss of balance was developed. The application of the model was illustrated by using it to reconstruct a real fall from height. From among the 28 sets of initial conditions, those whose application made it possible to reconstruct the most probable version of the incident was selected. The selection was based on comparison of the results of the reconstruction with information contained in the accident report. Results in the form of estimated

  13. TU-H-CAMPUS-JeP2-01: Inter-Observer Delineation Comparison of Visible Glandular Breast Tissue On Magnetic Resonance Imaging and Computed Tomography (prone and Supine)

    International Nuclear Information System (INIS)

    Pogson, EM; Delaney, G; Yap, M; Ahern, V; Boxer, M; David, S; Dimigen, M; Harvey, J; Koh, E; Batumalai, V; Lim, K; Papadatos, G; Metcalfe, P

    2016-01-01

    Purpose: Breast cancers predominantly arise from Glandular Breast Tissue (GBT). If the GBT can be treated effectively post-operatively utilising radiotherapy this may be adequate volumetric coverage for adjuvant breast radiotherapy. Adequate imaging of the GBT is necessary and will be assessed between MRI and CT modalities. GBT visualisation is acknowledged to be qualitatively superior on Magnetic Resonance Image (MRI) compared to Computed Tomography (CT), the current radiotherapy imaging standard, however this has not been quantitatively assessed. For radiotherapy purposes it is important that any treatment volume can be consistently defined between observers. This study investigates the consistency of CT and MRI GBT contours for potential radiotherapy planning. Methods: Ten experts (9 breast radiation oncologists and 1 radiologist) contoured the extent of the visible GBT for 33 patients on MRI and CT (both without contrast), which was performed according to a contouring guideline in supine and prone patient positions. The GBT volume was not a conventional whole breast radiotherapy planning volume, but rather the extent of GBT that was indicated from the CT or MR imaging. Volumes were compared utilizing the dice similarity coefficient (DSC), kappa statistic, and Hausdorff Distances (HDs) to ascertain the modality that was most consistently volumed. Results: The inter-observer concordance was of substantial agreement (kappa above 0.6) for the CT supine, CT prone, MRI supine and MRI prone datasets. The MRI GBT volumes were larger than the CT GBT volumes (p<0.001). Inter-observer conformity was higher for CT than MRI, although the magnitude of this difference was small (VOI<0.04). Conformity between modalities (CT and MRI) was in agreement for both prone and supine, DSC=0.75. Prone GBT volumes were larger than supine for both MRI and CT. Conclusion: MRI improves the extent of GBT delineation. The role of MRI guided, GBT-targeted radiotherapy requires investigation in

  14. TU-H-CAMPUS-JeP2-01: Inter-Observer Delineation Comparison of Visible Glandular Breast Tissue On Magnetic Resonance Imaging and Computed Tomography (prone and Supine)

    Energy Technology Data Exchange (ETDEWEB)

    Pogson, EM [Institute of Medical Physics, University of Sydney, Sydney, NSW (Australia); University of Wollongong, Wollongong, NSW (Australia); Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); Delaney, G; Yap, M [Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); South Western Sydney Clinical School, University of New South Wales, Sydney, NSW (Australia); School of Medicine, University of Western Sydney, Sydney, NSW (Australia); Ahern, V [Westmead Hospital, Westmead, NSW (Australia); Boxer, M [Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); David, S [Peter MacCallum Cancer Institute,, Melbourne, VIC (Australia); Dimigen, M [Department of Radiology, Liverpool Hospital, NSW (United Kingdom); Harvey, J [University of Queensland, Brisbane, QLD (Australia); Princess Alexandra Hospital, QLD (Australia); Koh, E; Batumalai, V [Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); South Western Sydney Clinical School, University of New South Wales, Sydney, NSW (Australia); Lim, K; Papadatos, G [Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Metcalfe, P [University of Wollongong, Wollongong, NSW (Australia); Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); and others

    2016-06-15

    Purpose: Breast cancers predominantly arise from Glandular Breast Tissue (GBT). If the GBT can be treated effectively post-operatively utilising radiotherapy this may be adequate volumetric coverage for adjuvant breast radiotherapy. Adequate imaging of the GBT is necessary and will be assessed between MRI and CT modalities. GBT visualisation is acknowledged to be qualitatively superior on Magnetic Resonance Image (MRI) compared to Computed Tomography (CT), the current radiotherapy imaging standard, however this has not been quantitatively assessed. For radiotherapy purposes it is important that any treatment volume can be consistently defined between observers. This study investigates the consistency of CT and MRI GBT contours for potential radiotherapy planning. Methods: Ten experts (9 breast radiation oncologists and 1 radiologist) contoured the extent of the visible GBT for 33 patients on MRI and CT (both without contrast), which was performed according to a contouring guideline in supine and prone patient positions. The GBT volume was not a conventional whole breast radiotherapy planning volume, but rather the extent of GBT that was indicated from the CT or MR imaging. Volumes were compared utilizing the dice similarity coefficient (DSC), kappa statistic, and Hausdorff Distances (HDs) to ascertain the modality that was most consistently volumed. Results: The inter-observer concordance was of substantial agreement (kappa above 0.6) for the CT supine, CT prone, MRI supine and MRI prone datasets. The MRI GBT volumes were larger than the CT GBT volumes (p<0.001). Inter-observer conformity was higher for CT than MRI, although the magnitude of this difference was small (VOI<0.04). Conformity between modalities (CT and MRI) was in agreement for both prone and supine, DSC=0.75. Prone GBT volumes were larger than supine for both MRI and CT. Conclusion: MRI improves the extent of GBT delineation. The role of MRI guided, GBT-targeted radiotherapy requires investigation in

  15. Virtual prototyping of a semi-active transfemoral prosthetic leg.

    Science.gov (United States)

    Lui, Zhen Wei; Awad, Mohammed I; Abouhossein, Alireza; Dehghani-Sanij, Abbas A; Messenger, Neil

    2015-05-01

    This article presents a virtual prototyping study of a semi-active lower limb prosthesis to improve the functionality of an amputee during prosthesis-environment interaction for level ground walking. Articulated ankle-foot prosthesis and a single-axis semi-active prosthetic knee with active and passive operating modes were considered. Data for level ground walking were collected using a photogrammetric method in order to develop a base-line simulation model and with the hip kinematics input to verify the proposed design. The simulated results show that the semi-active lower limb prosthesis is able to move efficiently in passive mode, and the activation time of the knee actuator can be reduced by approximately 50%. Therefore, this semi-active system has the potential to reduce the energy consumption of the actuators required during level ground walking and requires less compensation from the amputee due to lower deviation of the vertical excursion of body centre of mass. © IMechE 2015.

  16. Influence of mechanical stimulation on human dermal fibroblasts derived from different body sites.

    Science.gov (United States)

    Kuang, Ruixia; Wang, Zhiguo; Xu, Quanchen; Liu, Su; Zhang, Weidong

    2015-01-01

    Mechanical stimulation is highly associated with pathogenesis of human hypertrophic scar. Although much work has focused on the influence of mechanical stress on fibroblast populations from various tissues and organs in the human body, their effects on cultured dermal fibroblasts by the area of the body have not been as well studied. In this study, cultures of skin fibroblasts from two different body sites were subjected to cyclic mechanical stimulation with a 10% stretching amplitude at a frequency of 0.1 Hz for 24, 36 and 48 hours, respectively, and thereafter harvested for experimental assays. Fibroblasts from scapular upper back skin, subjected to mechanical loads for 36 and 48 hours, respectively, were observed to proliferate at a higher rate and reach confluent more rapidly during in vitro culturing, had higher expression levels of mRNA and protein production of integrin β1, p130Cas and TGF β1 versus those from medial side of upper arm. These data indicate that skin fibroblasts, with regard to originated body sites studied in the experiments, display a diversity of mechanotransduction properties and biochemical reactions in response to applied mechanical stress, which contributes to the increased susceptibility to hypertrophic scars formation at certain areas of human body characterized by higher skin and muscle tension.

  17. Skin Sensitive Difference of Human Body Sections under Clothing-Smirnov Test of Skin Surface Temperatures' Dynamic Changing

    Institute of Scientific and Technical Information of China (English)

    LI Jun; WU Hai-yan; WANG Yun-yi

    2004-01-01

    Skin sensitive difference of human body sections under clothing is the theoretic foundation of thermal insulation clothing design.By a new method of researching on clothing comfort perception,the skin temperature live changing procedure of human body sections affected by the same cold stimulation is inspected.Furthermore with the Smirnov test the skin temperatures dynamic changing patterns of main human body sections are obtained.

  18. Electromagnetic Fields at the Surface of Human-Body Cylinders

    DEFF Research Database (Denmark)

    Kammersgaard, Nikolaj Peter Iversen; Kvist, Søren H.; Thaysen, Jesper

    2016-01-01

    transverse electric and transverse magnetic polarization. The results show that the material assumption when modeling the human body as a homogeneous material is very important. Furthermore, it is shown that one assumption might lead to higher fields for a specific polarization, angle of incidence...

  19. Inclusion bodies in loggerhead erythrocytes are associated with unstable hemoglobin and resemble human Heinz bodies.

    Science.gov (United States)

    Basile, Filomena; Di Santi, Annalisa; Caldora, Mercedes; Ferretti, Luigi; Bentivegna, Flegra; Pica, Alessandra

    2011-08-01

    The aim of this study was to clarify the role of the erythrocyte inclusions found during the hematological screening of loggerhead population of the Mediterranean Sea. We studied the erythrocyte inclusions in blood specimens collected from six juvenile and nine adult specimens of the loggerhead turtle, Caretta caretta, from the Adriatic and Tyrrhenian Seas. Our study indicates that the percentage of mature erythrocytes containing inclusions ranged from 3 to 82%. Each erythrocyte contained only one round inclusion body. Inclusion bodies stained with May Grünwald-Giemsa show that their cytochemical and ultrastructure characteristics are identical to those of human Heinz bodies. Because Heinz bodies originate from the precipitation of unstable hemoglobin (Hb) and cause globular osmotic resistance to increase, we analyzed loggerhead Hb using electrophoresis and high-performance liquid chromatography to detect and quantitate Hb fractions. We also tested the resistance of Hb to alkaline pH, heat, isopropanol denaturation, and globular osmosis. Our hemogram results excluded the occurrence of any infection, which could be associated with an inclusion body, in all the specimens. Negative Feulgen staining indicated that the inclusion bodies are not derived from DNA fragmentation. We hypothesize that amino acid substitutions could explain why loggerhead Hb precipitates under normal physiologic conditions, forming Heinz bodies. The identification of inclusion bodies in loggerhead erythrocytes allow us to better understand the haematological characteristics and the physiology of these ancient reptiles, thus aiding efforts to conserve such an endangered species. Copyright © 2011 Wiley-Liss, Inc., A Wiley Company.

  20. Design of flexible thermoelectric generator as human body sensor

    DEFF Research Database (Denmark)

    Qing, Shaowei; Rezaniakolaei, Alireza; Rosendahl, Lasse Aistrup

    2018-01-01

    Flexible thermoelectric generator (TEG) became an attractive technology that has been widely used especially for curved surfaces applications. This study aims an optimal design of a flexible TEG for human body application. The flexible TEG is part of a sensor and supplies required electrical power...... for data transmission by the sensor. The TEG module includes ink based thermoelements made of nano-carbon bismuth telluride materials. One flexible fin conducts the body heat to the TEG module and there are two fins that exchange the heat from the cold side of the TEG to the ambient. The proposed design...

  1. Sympathetic activation during early pregnancy in humans

    Science.gov (United States)

    Jarvis, Sara S; Shibata, Shigeki; Bivens, Tiffany B; Okada, Yoshiyuki; Casey, Brian M; Levine, Benjamin D; Fu, Qi

    2012-01-01

    Sympathetic activity has been reported to increase in normotensive pregnant women, and to be even greater in women with gestational hypertension and preeclampsia at term. Whether sympathetic overactivity develops early during pregnancy, remaining high throughout gestation, or whether it only occurs at term providing the substrate for hypertensive disorders is unknown. We tested the hypothesis that sympathetic activation occurs early during pregnancy in humans. Eleven healthy women (29 ± 3 (SD) years) without prior hypertensive pregnancies were tested during the mid-luteal phase (PRE) and early pregnancy (EARLY; 6.2 ± 1.2 weeks of gestation). Muscle sympathetic nerve activity (MSNA) and haemodynamics were measured supine, at 30 deg and 60 deg upright tilt for 5 min each. Blood samples were drawn for catecholamines, direct renin, and aldosterone. MSNA was significantly greater during EARLY than PRE (supine: 25 ± 8 vs. 14 ± 8 bursts min−1, 60 deg tilt: 49 ± 14 vs. 40 ± 10 bursts min−1; main effect, P < 0.05). Resting diastolic pressure trended lower (P = 0.09), heart rate was similar, total peripheral resistance decreased (2172 ± 364 vs. 2543 ± 352 dyne s cm−5; P < 0.05), sympathetic vascular transduction was blunted (0.10 ± 0.05 vs. 0.36 ± 0.47 units a.u.−1 min−1; P < 0.01), and both renin (supine: 27.9 ± 6.2 vs. 14.2 ± 8.7 pg ml−1, P < 0.01) and aldosterone (supine: 16.7 ± 14.1 vs. 7.7 ± 6.8 ng ml−1, P = 0.05) were higher during EARLY than PRE. These results suggest that sympathetic activation is a common characteristic of early pregnancy in humans despite reduced diastolic pressure and total peripheral resistance. These observations challenge conventional thinking about blood pressure regulation during pregnancy, showing marked sympathetic activation occurring within the first few weeks of conception, and may provide the substrate for pregnancy induced cardiovascular complications. PMID:22687610

  2. Automatic identification of inertial sensor placement on human body segments during walking

    NARCIS (Netherlands)

    Weenk, D.; van Beijnum, Bernhard J.F.; Baten, Christian T.M.; Hermens, Hermanus J.; Veltink, Petrus H.

    2013-01-01

    We present a novel method for the automatic identification of inertial sensors on human body segments during walking. This method allows the user to place (wireless) inertial sensors on arbitrary body segments. Next, the user walks for just a few seconds and the segment to which each sensor is

  3. Human Body 3D Posture Estimation Using Significant Points and Two Cameras

    Science.gov (United States)

    Juang, Chia-Feng; Chen, Teng-Chang; Du, Wei-Chin

    2014-01-01

    This paper proposes a three-dimensional (3D) human posture estimation system that locates 3D significant body points based on 2D body contours extracted from two cameras without using any depth sensors. The 3D significant body points that are located by this system include the head, the center of the body, the tips of the feet, the tips of the hands, the elbows, and the knees. First, a linear support vector machine- (SVM-) based segmentation method is proposed to distinguish the human body from the background in red, green, and blue (RGB) color space. The SVM-based segmentation method uses not only normalized color differences but also included angle between pixels in the current frame and the background in order to reduce shadow influence. After segmentation, 2D significant points in each of the two extracted images are located. A significant point volume matching (SPVM) method is then proposed to reconstruct the 3D significant body point locations by using 2D posture estimation results. Experimental results show that the proposed SVM-based segmentation method shows better performance than other gray level- and RGB-based segmentation approaches. This paper also shows the effectiveness of the 3D posture estimation results in different postures. PMID:24883422

  4. Non-invasive measurement of calcium and phosphorus in human body by NAA technique

    International Nuclear Information System (INIS)

    Wang Haiying; Luo Xianqing; Huang Hanqiao

    1995-01-01

    A system of measuring calcium and phosphorus in human legs has been developed by the use of partial-body neutron activation analysis and partial-body counting technique. The results are compared for the normals and osteoporotic patients

  5. Harmful effects of mobile phone waves on blood tissues of the human body

    OpenAIRE

    Kumar, Vijay; Ahmad, Mushtaq; Sharma, A. K.

    2013-01-01

      Abstract. Penetration of electromagnetic waves emitted by mobile phones into human skin and blood was studied. The transmitted waves from these mobile phones were exposed to the human body and were penetrated into the body where field was reduced exponentially with depth. As the reduction in field was due to absorption of power, specific absorption rate was calculated and compared with permissible limit given by International Commission on Non-ionizing Radiation Protection (ICNIRP) and Worl...

  6. Body mass, energy intake, and water consumption of rats and humans during space flight

    Science.gov (United States)

    Wade, C. E.; Miller, M. M.; Baer, L. A.; Moran, M. M.; Steele, M. K.; Stein, T. P.

    2002-01-01

    Alteration of metabolism has been suggested as a major limiting factor to long-term space flight. In humans and primates, a negative energy balance has been reported. The metabolic response of rats to space flight has been suggested to result in a negative energy balance. We hypothesized that rats flown in space would maintain energy balance as indicated by maintenance of caloric intake and body mass gain. Further, the metabolism of the rat would be similar to that of laboratory-reared animals. We studied the results from 15 space flights lasting 4 to 19 d. There was no difference in average body weight (206 +/- 13.9 versus 206 +/- 14.8 g), body weight gain (5.8 +/- 0.48 versus 5.9 +/- 0.56 g/d), caloric intake (309 +/- 21.0 versus 309 +/- 20.1 kcal/kg of body mass per day), or water intake (200 +/- 8.6 versus 199 +/- 9.3 mL/kg of body mass per day) between flight and ground control animals. Compared with standard laboratory animals of similar body mass, no differences were noted. The observations suggested that the negative balance observed in humans and non-human primates may be due to other factors in the space-flight environment.

  7. Body composition of two human cadavers by neutron activation and chemical analysis

    International Nuclear Information System (INIS)

    Knight, G.S.; Beddoe, A.H.; Streat, S.J.; Hill, G.L.

    1986-01-01

    In vivo neutron activation analysis (NAA) is currently used to measure body composition in metabolic and nutritional studies in many clinical situations, but has not previously been validated by comparison with chemical analysis of human cadavers. Total body nitrogen (TBN) and chlorine (TBCl) were measured in two human cadavers by NAA before homogenization and chemical analysis (CHEM) after (cadaver 1: TBN, 1.47 NAA, 1.51 CHEM; TBCl, 0.144 NAA, 0.147 CHEM; cadaver 2: TBN, 0.576 NAA, 0.572 CHEM; TBCl, 0.0227 NAA, 0.0250 CHEM). The homogenates were also analyzed by NAA, and no significant differences were found, indicating that the effects of elemental inhomogeneity on the measurement of TBN and TBCl are insignificant. Total body water, fat, protein, minerals, and carbohydrates were measured chemically for each cadaver and compared with estimates for these compartments obtained from a body composition model, which when used in vivo involves NAA and tritium dilution. The agreement found justifies the use of the model for the measurement of changes in total body protein, water, and fat in sequential studies in groups of patients

  8. The impact of Body Worlds on adult visitors' knowledge on human anatomy: A preliminary study.

    Science.gov (United States)

    Fonseca, Guilherme R B C; Finn, Gabrielle M

    2016-05-01

    Body Worlds is an anatomical exhibition that shows human remains to the public. It has been considered controversial since it raises ethical tensions and issues. However, organizers and supporters of Body Worlds have claimed the exhibition is intended to promote visitors' understanding over the human body. Despite these claims, no studies were found that support or refute the hypothesis that a visit to Body Worlds increases the public's objective knowledge on human anatomy. Consequently, the objective of this study was to determine the impact of Body Worlds on anatomical knowledge. We constructed and delivered a questionnaire to both a previsit random sample and a postvisit random sample of visitors of Body Worlds' event Facets of Life, in Berlin. The questionnaire was available in both English and German languages and contained (a) basic sociodemographic questions and (b) a valid and reliable anatomy quiz. The quiz consisted of 16 multiple-choice questions that assessed the ability to identify the location of major anatomical structures on the human body. Average scores achieved on the quiz by the postvisit sample (X¯= 9.08, s = 2.48, n = 164) were significantly higher (unpaired t = 3.3957, P = 0.0008) than those achieved by the previsit sample (X¯= 8.11, s = 2.69, n = 167). Our results suggest that a visit to Body Worlds' event Facets of Life may have a beneficial effect in anatomical knowledge. However, further studies with better empirical designs and fewer limitations are needed to confirm our results. © 2016 Wiley Periodicals, Inc.

  9. Finite element crash simulations of the human body: Passive and ...

    Indian Academy of Sciences (India)

    of the vehicle that cause injury and their zone of action on the human body. For example .... The commonly used hyper elastic material models to predict the soft tissue responses ..... forces during post impact move- .... electromyogram in man.

  10. Transient interaction model of electromagnetic field generated by lightning current pulses and human body

    International Nuclear Information System (INIS)

    Iváncsy, T; Kiss, I; Tamus, Z Á; Szücs, L

    2015-01-01

    The lightning current generates time-varying magnetic field near the down-conductor and the down-conductors are mounted on the wall of the buildings where residential places might be situated. It is well known that the rapidly changing magnetic fields can generate dangerous eddy currents in the human body.The higher duration and gradient of the magnetic field can cause potentially life threatening cardiac stimulation. The coupling mechanism between the electromagnetic field and the human body is based on a well-known physical phenomena (e.g. Faradays law of induction). However, the calculation of the induced current is very complicated because the shape of the organs is complex and the determination of the material properties of living tissues is difficult, as well. Our previous study revealed that the cardiac stimulation is independent of the rising time of the lightning current and only the peak of the current counts.In this study, the authors introduce an improved model of the interaction of electromagnetic fields of lighting current near down-conductor and human body. Our previous models are based on the quasi stationer field calculations, the new improved model is a transient model. This is because the magnetic field around the down-conductor and in the human body can be determined more precisely, therefore the dangerous currents in the body can be estimated. (paper)

  11. Thermal sensation during mild hyperthermia is modulated by acute postural change in humans.

    Science.gov (United States)

    Takeda, Ryosuke; Imai, Daiki; Suzuki, Akina; Ota, Akemi; Naghavi, Nooshin; Yamashina, Yoshihiro; Hirasawa, Yoshikazu; Yokoyama, Hisayo; Miyagawa, Toshiaki; Okazaki, Kazunobu

    2016-12-01

    Thermal sensation represents the primary stimulus for behavioral and autonomic thermoregulation. We assessed whether the sensation of skin and core temperatures for the driving force of behavioral thermoregulation was modified by postural change from the supine (Sup) to sitting (Sit) during mild hyperthermia. Seventeen healthy young men underwent measurements of noticeable increase and decrease (±0.1 °C/s) of skin temperature (thresholds of warm and cold sensation on the skin, 6.25 cm 2 of area) at the forearm and chest and of the whole-body warm sensation in the Sup and Sit during normothermia (NT; esophageal temperature (T es ), ∼36.6 °C) and mild hyperthermia (HT; T es , ∼37.2 °C; lower legs immersion in 42 °C of water). The threshold for cold sensation on the skin at chest was lower during HT than NT in the Sit (P sensation on the skin at both sites remained unchanged with changes in body posture or temperature. The whole-body warm sensation was higher during HT than NT in both postures and higher in the Sit than Sup during both NT and HT (all, P sensation during mild hyperthermia is modulated by postural change from supine to sitting to sense lesser cold on the skin and more whole-body warmth.

  12. Applications for Electrical Impedance Tomography (EIT) and Electrical Properties of the Human Body.

    Science.gov (United States)

    Lymperopoulos, Georgios; Lymperopoulos, Panagiotis; Alikari, Victoria; Dafogianni, Chrisoula; Zyga, Sofia; Margari, Nikoletta

    2017-01-01

    Electrical Impedance Tomography (EIT) is a promising application that displays changes in conductivity within a body. The basic principle of the method is the repeated measurement of surface voltages of a body, which are a result of rolling injection of known and small-volume sinusoidal AC current to the body through the electrodes attached to its surface. This method finds application in biomedicine, biology and geology. The objective of this paper is to present the applications of Electrical Impedance Tomography, along with the method's capabilities and limitations due to the electrical properties of the human body. For this purpose, investigation of existing literature has been conducted, using electronic databases, PubMed, Google Scholar and IEEE Xplore. In addition, there was a secondary research phase, using paper citations found during the first research phase. It should be noted that Electrical Impedance Tomography finds use in a plethora of medical applications, as the different tissues of the body have different conductivities and dielectric constants. Main applications of EIT include imaging of lung function, diagnosis of pulmonary embolism, detection of tumors in the chest area and diagnosis and distinction of ischemic and hemorrhagic stroke. EIT advantages include portability, low cost and safety, which the method provide, since it is a noninvasive imaging method that does not cause damage to the body. The main disadvantage of the method, which blocks its wider spread, appears in the image composition from the voltage measurements, which are conducted by electrodes placed on the periphery of the body, because the injected currents are affected nonlinearly by the general distribution of the electrical properties of the body. Furthermore, the complex impedance of the skin-electrode interface can be modelled by using a capacitor and two resistor, as a result of skin properties. In conclusion, Electrical Impedance Tomography is a promising method for the

  13. Using digital educational objects to teach human body systems at a countryside school

    Directory of Open Access Journals (Sweden)

    Silvio Ferreira dos Santos

    2017-12-01

    Full Text Available The purpose of this study is to assess the use of educational software and mobile device applications to teach about the human body at a rural school. It is an action research, with a qualitative approach, developed in 2016 and involving 14 students from the 8th year Elementary Education at the Escola Estadual Sol Nascente in Confresa-MT. The chosen software and application was the Human Body Atlas and 3D Human Body Systems, emphasizing on the digestive and circulation systems. The results from the pre-and post-test, which comprised 20 questions together, corroborate the hypothesis that the use of digital educational objects benefits the education process. Students learned better the systems in comparison with when only traditional resources, such as a didactic book, was used. Such advancement could be harnessed to the fact that the resources make use of 3D images and point out each part of the body, besides providing important information and curiosities about the subject. It is therefore expected that digital technologies may be increasingly inserted and explored in pedagogical practices, since those resources allow for studying and solving queries, by broadening educational space and time.

  14. A whole body atlas for segmentation and delineation of organs for radiation therapy planning

    International Nuclear Information System (INIS)

    Qatarneh, S.M.; Crafoord, J.; Kramer, E.L.; Maguire, G.Q.; Brahme, A.; Noz, M.E.; Hyoedynmaa, S.

    2001-01-01

    A semi-automatic procedure for delineation of organs to be used as the basis of a whole body atlas database for radiation therapy planning was developed. The Visible Human Male Computed Tomography (CT)-data set was used as a 'standard man' reference. The organ of interest was outlined manually and then transformed by a polynomial warping algorithm onto a clinical patient CT. This provided an initial contour, which was then adjusted and refined by the semi-automatic active contour model to find the final organ outline. The liver was used as a test organ for evaluating the performance of the procedure. Liver outlines obtained by the segmentation algorithm on six patients were compared to those manually drawn by a radiologist. The combination of warping and semi-automatic active contour model generally provided satisfactory segmentation results, but the procedure has to be extended to three dimensions

  15. The effect of stress on core and peripheral body temperature in humans.

    Science.gov (United States)

    Vinkers, Christiaan H; Penning, Renske; Hellhammer, Juliane; Verster, Joris C; Klaessens, John H G M; Olivier, Berend; Kalkman, Cor J

    2013-09-01

    Even though there are indications that stress influences body temperature in humans, no study has systematically investigated the effects of stress on core and peripheral body temperature. The present study therefore aimed to investigate the effects of acute psychosocial stress on body temperature using different readout measurements. In two independent studies, male and female participants were exposed to a standardized laboratory stress task (the Trier Social Stress Test, TSST) or a non-stressful control task. Core temperature (intestinal and temporal artery) and peripheral temperature (facial and body skin temperature) were measured. Compared to the control condition, stress exposure decreased intestinal temperature but did not affect temporal artery temperature. Stress exposure resulted in changes in skin temperature that followed a gradient-like pattern, with decreases at distal skin locations such as the fingertip and finger base and unchanged skin temperature at proximal regions such as the infra-clavicular area. Stress-induced effects on facial temperature displayed a sex-specific pattern, with decreased nasal skin temperature in females and increased cheek temperature in males. In conclusion, the amplitude and direction of stress-induced temperature changes depend on the site of temperature measurement in humans. This precludes a direct translation of the preclinical stress-induced hyperthermia paradigm, in which core temperature uniformly rises in response to stress to the human situation. Nevertheless, the effects of stress result in consistent temperature changes. Therefore, the present study supports the inclusion of body temperature as a physiological readout parameter of stress in future studies.

  16. Effect of body position changes on pulmonary gas exchange in Eisenmenger's syndrome.

    Science.gov (United States)

    Sandoval, J; Alvarado, P; Martínez-Guerra, M L; Gómez, A; Palomar, A; Meza, S; Santos, E; Rosas, M

    1999-04-01

    Preliminary studies on sleep of patients with congenital heart disease and Eisenmenger's syndrome (ES) at our institution demonstrated nocturnal worsening arterial unsaturation, which appeared to be a body position-related phenomenon. To investigate the potential effect of body position on gas exchange in ES, we carried out a prospective study of 28 patients (mean age, 34.8 +/- 11.7 yr) with established ES due to congenital heart disease. In every patient, arterial blood gases were performed during both sitting and supine positions under three different conditions: room air, while breathing 100% oxygen, and after breathing oxygen at a flow rate of 3 L/min through nasal prongs. Alveolar oxygen pressure (PaO2) for the calculation of alveolar-arterial oxygen tension differences (AaPO2) was derived from the alveolar gas equation using PaCO2 and assuming R = 1. We used paired t test, repeated-measures two-way ANOVA with Bonferroni's test, and regression analysis. From sitting to supine position on room air, there was a significant decrease in PaO2 (from 52.5 +/- 7.5 to 47.5 +/- 5.5 mm Hg; p position. A ventilation-perfusion (V/Q) distribution abnormality and/or a diffusion limitation phenomenon rather than an increase in true shunt may be the mechanisms responsible for this finding. The response to nasal O 2 we observed warrants a trial with long-term nocturnal oxygen therapy in these patients.

  17. Effects of body position and sex group on tongue pressure generation.

    Science.gov (United States)

    Dietsch, Angela M; Cirstea, Carmen M; Auer, Ed T; Searl, Jeff P

    2013-11-01

    Fine control of orofacial musculature is necessary to precisely accelerate and decelerate the articulators across exact distances for functional speech and coordinated swallows (Amerman & Parnell, 1990; Benjamin, 1997; Kent, Duffy, Slama, Kent, & Clift, 2001). Enhanced understanding of neural control for such movements could clarify the nature of and potential remediation for some dysarthrias and other orofacial myofunctional impairments. Numerous studies have measured orolingual force and accuracy during speech and nonspeech tasks, but have focused on young adults, maximum linguapalatal pressures, and upright positioning (O'Day, Frank, Montgomery, Nichols, & McDade, 2005; Solomon & Munson, 2004; Somodi, Robin, & Luschei, 1995; Youmans, Youmans, & Stierwalt, 2009). Patients' medical conditions or testing procedures such as concurrent neuroimaging may preclude fully upright positioning during oral motor assessments in some cases. Since judgments about lingual strength and coordination can influence clinical decisions regarding the functionality of swallowing and speech, it is imperative to understand any effects of body positioning differences. In addition, sex differences in the control of such tasks are not well defined. Therefore, this study evaluated whether pressures exerted during tongue movements differ in upright vs. supine body position in healthy middle-aged men and women. Twenty healthy middle-aged adults compressed small air-filled plastic bulbs in the oral cavity at predetermined fractions of task-specific peak pressure in a randomized block design. Tasks including phoneme repetitions and nonspeech isometric contractions were executed in upright and supine positions. Participants received continuous visual feedback regarding targets and actual exerted pressures. Analyses compared average pressure values for each subject, task, position, and effort level. Speech-like and nonspeech tongue pressures did not differ significantly across body position or sex

  18. Supine Versus Prone Position During Percutaneous Nephrolithotomy: A Report from the Clinical Research Office of the Endourological Society Percutaneous Nephrolithotomy Global Study

    DEFF Research Database (Denmark)

    G. Vadivia, José; M. Scarpa, Roberto; Duvdevani, Mordechai

    2011-01-01

    To determine differences in patients' characteristics, operative time and procedures, and perioperative outcomes between prone and supine positioning in percutaneous nephrolithotomy (PCNL) using the Clinical Research Office of the Endourological Society (CROES) PCNL Global Study database....

  19. Functional studies of the oesophagus with sulfur-colloid of sup(99m)Tc and gamma-camera

    International Nuclear Information System (INIS)

    Veiga-Fernandes, F.; Costa, P.M.; Pinheiro, M.F.; Guerreiro, D.

    1982-01-01

    A scintiscanning technique which allows sequential detection and quantification of gastro-oesophageal reflux (GER), and study of the oesophageal emptying of a liquid and semi-solid food is presented. At first patients swallowed 5 ml of water containing 1 mCi sup(99m)Tc sulfur-colloid and oesophageal activity is recorded from an anterior view by a gamma-camera. Then, patients ingest 300 ml of water that clear the oesophagus and fill up the stomach. GER index is calculated according to the formula GER = (Ae - Ab)/Ag) x 100, where Ae is the activity in the oesophagus; Ab, is the background activity; and Ag is the gastric activity. GER index presented corresponds to a median of three determinations in upright, supine and supine position with abdominal pressure of 4 kilos. The oesophageal transit time of a semi-solid food in upright and supine position is registered 5 minutes after GER studies through two areas of interest which are positioned: one in the superior third and the other in the inferior third of the oesophagus. Normal GER reflux index was, 0.84 +- 0.37 in the upright position; 0.87 +- 0.43 in the supine position; and 0.90 +- 0.56 in the supine position plus abdominal pressure

  20. Pulmonary atelectasis in patients with neurological or muscular disease. Gravity-related lung compression by the heart and intra-abdominal organs on persistent supine position

    International Nuclear Information System (INIS)

    Toyoshima, Mitsuo; Maeoka, Yukinori; Kawahara, Hitoshi; Maegaki, Yoshihiro; Ohno, Kousaku

    2006-01-01

    We report 10 cases of pulmonary atelectasis diagnosed by chest computed tomography in patients with neurological or muscular disease. Atelectasis was frequently seen in hypotonic patients who could not roll over on their own. The atelectases located mostly in the dorsal bronchopulmonary segments, adjacent to the heart or diaphragm. Atelectasis diminished in two patients after they became able to roll themselves over. Gravity-related lung compression by the heart and intra-abdominal organs on persistent supine position can cause pulmonary atelectasis in patients with neurological or muscular disease who can not roll over by their own power. To confirm that the prone position reduces compression of the lungs, chest computed tomography was performed in both the supine and the prone position in three patients. Sagittal images with three-dimensional computed tomographic reconstruction revealed significant sternad displacements of the heart and caudal displacements of the dorsal portion of the diaphragm on prone position compared with supine position. The prone position, motor exercises for rolling over, and biphasic cuirass ventilation are effective in reducing gravity-related lung compression. Some patients with intellectual disabilities were also able to cooperate in chest physiotherapy. Chest physiotherapy is useful in preventing atelectasis in patients with neurological or muscular disease. (author)

  1. [THE LEGAL STATUS OF ELEMENTS AND PRODUCTS OF THE HUMAN BODY: OBJECT OR SUBJECT OF LAW?].

    Science.gov (United States)

    De Lameigné, Anaïs Gayte-Papon

    2015-07-01

    The 2004 Act on bioethics has amended the 1994 Act regarding the donation and the use of elements and products of the human body, medically assisted procreation and prenatal diagnosis. The very purpose of these laws led the legislature not to attempt the summa divisio order distinguishing the object to the person. The analysis of bioethical laws reveals the consecration of the non-commercialization of the human body at the expense of its unavailability. Bioethical laws appear to be catalysts of biological scientific advances releasing the status of the components and the products of the human body while framing it. By limiting scientific opportunities, they prevent human beings from trying to play the sorcerer's apprentice.

  2. The Thermal Plume above a Standing Human Body Exposed to Different Air Distribution Strategies

    DEFF Research Database (Denmark)

    Liu, Li; Nielsen, Peter V.; Li, Yuguo

    2009-01-01

    This study compares the impact of air distribution on the thermal plume above a human body in indoor environment. Three sets of measurements are conducted in a full-scale test room with different ventilation conditions. One breathing thermal manikin standing in the room is used to simulate...... the human body. Long-time average air velocity profiles at locations closely above the manikin are taken to identify the wandering thermal plume....

  3. Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene.

    Science.gov (United States)

    Teeter, Matthew G; Goyal, Prateek; Yuan, Xunhua; Howard, James L; Lanting, Brent A

    2018-01-01

    The purpose of this study is to measure acetabular cup position and wear of the highly crosslinked polyethylene liner in the supine and standing position for patients at a minimum of 10 years after the operation. A total of 38 patients were recruited at a mean of 12.5 years after the operation. All patients received a single acetabular cup design with a highly crosslinked liner and a 28-mm cobalt-chromium femoral head. Patients underwent supine and standing radiostereometric examinations in which the X-ray sources and detectors were positioned to obtain an anterior-posterior and cross-table lateral radiograph. Acetabular cup position and the three-dimensional wear rate were measured from the radiographs, and outcome scores were recorded for each patient. Anteversion significantly increased (P cup orientation and wear rate in either position. Highly crosslinked polyethylene is a forgiving bearing material. Although adherence to the traditional acetabular position target zone is recommended, ensuring hip stability and consideration of the patient's functional position are also important objectives to consider for the acetabular position. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. State-of-the-art measurements in human body composition: A moving frontier of clinical importance

    Science.gov (United States)

    Gallagher, D.; Shaheen, I.; Zafar, K.

    2010-01-01

    The measurement of human body composition allows for the estimation of body tissues, organs, and their distributions in living persons without inflicting harm. From a nutritional perspective, the interest in body composition has increased multi-fold with the global increase in the prevalence of obesity and its complications. The latter has driven in part the need for improved measurement methods with greater sensitivity and precision. There is no single gold standard for body-composition measurements in-vivo. All methods incorporate assumptions that do not apply in all individuals and the more accurate models are derived by using a combination of measurements, thereby reducing the importance of each assumption. This review will discuss why the measurement of body composition or human phenotyping is important; discuss new areas where the measurement of body composition (human phenotyping) is recognized as having important application; and will summarize recent advances made in new methodology. Reference will also be made to areas we cannot yet measure due to the lack of appropriate measurement methodologies, most especially measurements methods that provide information on kinetic states (not just static state) and metabolic function. PMID:21234275

  5. Design, development, and performance of an adapter for simulation of ocular melanoma patients in supine position for proton beam therapy

    International Nuclear Information System (INIS)

    Daftari, I.; Phillips, T.L.

    2003-01-01

    A patient assembly adapter system for ocular melanoma patient simulation was developed and its performance evaluated. The aim for the construction of the apparatus was to simulate the patients in supine position using a commercial x-ray simulator. The apparatus consists of a base plate, head immobilization holder, patient assembly system that includes fixation light and collimator system. The reproducibility of the repeated fixation was initially tested with a head phantom. Simulation and verification films were studied for seven consecutive patients treated with proton beam therapy. Patient's simulation was performed in a supine position using a dental fixation bite block and a thermoplastic head mask immobilization device with a patient adapter system. Two orthogonal x rays were used to obtain the x, y, and z coordinates of sutured tantalum rings for treatment planning with the EYEPLAN software. The verification films were obtained in treatment position with the fixation light along the central axis of the eye. The results indicate good agreement within 0.5 mm deviations. The results of this investigation showed that the same planning accuracy could be achieved by performing simulation using the adapter described above with a patient in the supine position as that obtained by performing simulation with the patient in the seated, treatment position. The adapter can also be attached to the head of the chair for simulating in the seated position using a fixed x-ray unit. This has three advantages: (1) this will save radiation therapists time; (2) it eliminates the need for arranging access to the treatment room, thus avoiding potential conflicts in treatment room usage; and (3) it allows the use of a commercial simulator

  6. Design, development, and performance of an adapter for simulation of ocular melanoma patients in supine position for proton beam therapy

    Science.gov (United States)

    Daftari, I.; Phillips, T. L.

    2003-06-01

    A patient assembly adapter system for ocular melanoma patient simulation was developed and its performance evaluated. The aim for the construction of the apparatus was to simulate the patients in supine position using a commercial x-ray simulator. The apparatus consists of a base plate, head immobilization holder, patient assembly system that includes fixation light and collimator system. The reproducibility of the repeated fixation was initially tested with a head phantom. Simulation and verification films were studied for seven consecutive patients treated with proton beam therapy. Patient's simulation was performed in a supine position using a dental fixation bite block and a thermoplastic head mask immobilization device with a patient adapter system. Two orthogonal x rays were used to obtain the x, y, and z coordinates of sutured tantalum rings for treatment planning with the EYEPLAN software. The verification films were obtained in treatment position with the fixation light along the central axis of the eye. The results indicate good agreement within 0.5 mm deviations. The results of this investigation showed that the same planning accuracy could be achieved by performing simulation using the adapter described above with a patient in the supine position as that obtained by performing simulation with the patient in the seated, treatment position. The adapter can also be attached to the head of the chair for simulating in the seated position using a fixed x-ray unit. This has three advantages: (1) this will save radiation therapists time; (2) it eliminates the need for arranging access to the treatment room, thus avoiding potential conflicts in treatment room usage; and (3) it allows the use of a commercial simulator.

  7. Design of Monitoring Tool Heartbeat Rate and Human Body Temperature Based on WEB

    Directory of Open Access Journals (Sweden)

    Jalinas

    2018-01-01

    Full Text Available The heart is one of the most important organs in the human body. One way to know heart health is to measure the number of heart beats per minute and body temperature also shows health, many heart rate and body temperature devices but can only be accessed offline. This research aims to design a heart rate detector and human body temperature that the measurement results can be accessed via web pages anywhere and anytime. This device can be used by many users by entering different ID numbers. The design consists of input blocks: pulse sensor, DS18B20 sensor and 3x4 keypad button. Process blocks: Arduino Mega 2560 Microcontroller, Ethernet Shield, router and USB modem. And output block: 16x2 LCD and mobile phone or PC to access web page. Based on the test results, this tool successfully measures the heart rate with an average error percentage of 2.702 % when compared with the oxymeter tool. On the measurement of body temperature get the result of the average error percentage of 2.18 %.

  8. SemiBoost: boosting for semi-supervised learning.

    Science.gov (United States)

    Mallapragada, Pavan Kumar; Jin, Rong; Jain, Anil K; Liu, Yi

    2009-11-01

    Semi-supervised learning has attracted a significant amount of attention in pattern recognition and machine learning. Most previous studies have focused on designing special algorithms to effectively exploit the unlabeled data in conjunction with labeled data. Our goal is to improve the classification accuracy of any given supervised learning algorithm by using the available unlabeled examples. We call this as the Semi-supervised improvement problem, to distinguish the proposed approach from the existing approaches. We design a metasemi-supervised learning algorithm that wraps around the underlying supervised algorithm and improves its performance using unlabeled data. This problem is particularly important when we need to train a supervised learning algorithm with a limited number of labeled examples and a multitude of unlabeled examples. We present a boosting framework for semi-supervised learning, termed as SemiBoost. The key advantages of the proposed semi-supervised learning approach are: 1) performance improvement of any supervised learning algorithm with a multitude of unlabeled data, 2) efficient computation by the iterative boosting algorithm, and 3) exploiting both manifold and cluster assumption in training classification models. An empirical study on 16 different data sets and text categorization demonstrates that the proposed framework improves the performance of several commonly used supervised learning algorithms, given a large number of unlabeled examples. We also show that the performance of the proposed algorithm, SemiBoost, is comparable to the state-of-the-art semi-supervised learning algorithms.

  9. Human body as a set of biometric features identified by means of optoelectronics

    Science.gov (United States)

    Podbielska, Halina; Bauer, Joanna

    2005-09-01

    Human body posses many unique, singular features that are impossible to copy or forge. Nowadays, to establish and to ensure the public security requires specially designed devices and systems. Biometrics is a field of science and technology, exploiting human body characteristics for people recognition. It identifies the most characteristic and unique ones in order to design and construct systems capable to recognize people. In this paper some overview is given, presenting the achievements in biometrics. The verification and identification process is explained, along with the way of evaluation of biometric recognition systems. The most frequently human biometrics used in practice are shortly presented, including fingerprints, facial imaging (including thermal characteristic), hand geometry and iris patterns.

  10. The Effect of Body Position on Pain Due to Nasal Continuous Positive Airway Pressure (CPAP in Premature Neonates: A Cross-Over Clinical Trial Study

    Directory of Open Access Journals (Sweden)

    Mahnaz Jabraeili

    2018-01-01

    Full Text Available Background The most common cause of admission to neonatal intensive care units (NICU is respiratory distress syndrome. One of the respiratory assistance methods is using nasal continuous positive airway pressure (CPAP. Regarding the importance of pain control which is one of the major priorities in neonatal nursing care, this study aimed to evaluate the effect of body position on pain due to nasal CPAP in premature neonates. Materials and Methods In this cross-over clinical trial, 50 premature neonates who were receiving nasal CPAP admitted to the NICU of Imam Reza Hospital, Kermanshah, Iran, were included. The neonates were randomly placed at three body positions (fetal, supine, and prone positions. Pain was measured by Astrid Lindgren Children’s Hospital Pain Scale Neonates (ALPS-Neo pain assessment scale. The collected data were analyzed using the SPSS software (Version 22.0. Results Significant difference existed regarding pain of nasal CPAP among body positions (p< 0.001. Mean (SD pain was 5.15 (0.822 in fetal position, 6.260 (0.747 in prone position and 7.326 (0.792 in supine position. Conclusion Body positioning in premature neonates under nasal CPAP in NICU can be effective as a non-pharmacologic method in alleviating pain due to nasal CPAP. Among the studied positions, the lowest pain score was seen in fetal position.

  11. Inactivation of human immunodeficiency virus (HIV) by ionizing radiation in body fluids and serological evidence

    International Nuclear Information System (INIS)

    Bigbee, P.D.; Sarin, P.S.; Humphreys, J.C.; Eubanks, W.G.; Sun, D.; Hocken, D.G.; Thornton, A.; Adams, D.E.; Simic, M.G.

    1989-01-01

    A method to use ionizing radiation to inactivate HIV (Human Immunodeficiency Virus) in human body fluids was studied in an effort to reduce the risk of accidental infection to forensic science laboratory workers. Experiments conducted indicate that an X-ray absorbed dose of 25 krad was required to completely inactivate HIV. This does not alter forensically important constituents such as enzymes and proteins in body fluids. This method of inactivation of HIV cannot be used on body fluids which will be subjected to deoxyribonucleic acid (DNA) typing

  12. Convective Heat Transfer Coefficients of the Human Body under Forced Convection from Ceiling

    DEFF Research Database (Denmark)

    Kurazumi, Yoshihito; Rezgals, Lauris; Melikov, Arsen Krikor

    2014-01-01

    The average convective heat transfer coefficient for a seated human body exposed to downward flow from above was determined. Thermal manikin with complex body shape and size of an average Scandinavian female was used. The surface temperature distribution of the manikin’s body was as the skin...... of the convective heat transfer coefficient of the whole body (hc [W/(m2•K)]) was proposed: hc=4.088+6.592V1.715 for a seated naked body at 20ºC and hc=2.874+7.427V1.345 for a seated naked body at 26ºC. Differences in the convective heat transfer coefficient of the whole body in low air velocity range, V

  13. Supine MRI for regional breast radiotherapy: imaging axillary lymph nodes before and after sentinel-node biopsy

    Science.gov (United States)

    van Heijst, Tristan C. F.; Eschbach-Zandbergen, Debora; Hoekstra, Nienke; van Asselen, Bram; Lagendijk, Jan J. W.; Verkooijen, Helena M.; Pijnappel, Ruud M.; de Waard, Stephanie N.; Witkamp, Arjen J.; van Dalen, Thijs; Desirée van den Bongard, H. J. G.; Philippens, Marielle E. P.

    2017-08-01

    Regional radiotherapy (RT) is increasingly used in breast cancer treatment. Conventionally, computed tomography (CT) is performed for RT planning. Lymph node (LN) target levels are delineated according to anatomical boundaries. Magnetic resonance imaging (MRI) could enable individual LN delineation. The purpose was to evaluate the applicability of MRI for LN detection in supine treatment position, before and after sentinel-node biopsy (SNB). Twenty-three female breast cancer patients (cTis-3N0M0) underwent 1.5 T MRI, before and after SNB, in addition to CT. Endurance for MRI was monitored. Axillary levels were delineated. LNs were identified and delineated on MRI from before and after SNB, and on CT, and compared by Wilcoxon signed-rank tests. LN locations and LN-based volumes were related to axillary delineations and associated volumes. Although postoperative effects were visible, LN numbers on postoperative MRI (median 26 LNs) were highly reproducible compared to preoperative MRI when adding excised sentinel nodes, and higher than on CT (median 11, p  <  0.001). LN-based volumes were considerably smaller than respective axillary levels. Supine MRI of LNs is feasible and reproducible before and after SNB. This may lead to more accurate RT target definition compared to CT, with potentially lower toxicity. With the MRI techniques described here, initiation of novel MRI-guided RT strategies aiming at individual LNs could be possible.

  14. Development of a human body RMN imaging device

    International Nuclear Information System (INIS)

    Saint-Jalmes, H.

    1984-03-01

    Imaging device for human body is studied in this thesis. The section images presented are got by a projection-reconstruction method associated to a section plane selection by an oscillating gradient application. Different stages of the machine development are presented: - design and calculation of a resistive magnet for very homogeneous field imaging - design of gradient coils for imaging magnets - realization of control and acquisition interfaces - realization of imaging software in real time [fr

  15. Detection and Classification of Human Body Odor Using an Electronic Nose

    Directory of Open Access Journals (Sweden)

    Teerakiat Kerdcharoen

    2009-09-01

    Full Text Available An electronic nose (E-nose has been designed and equipped with software that can detect and classify human armpit body odor. An array of metal oxide sensors was used for detecting volatile organic compounds. The measurement circuit employs a voltage divider resistor to measure the sensitivity of each sensor. This E-nose was controlled by in-house developed software through a portable USB data acquisition card with a principle component analysis (PCA algorithm implemented for pattern recognition and classification. Because gas sensor sensitivity in the detection of armpit odor samples is affected by humidity, we propose a new method and algorithms combining hardware/software for the correction of the humidity noise. After the humidity correction, the E-nose showed the capability of detecting human body odor and distinguishing the body odors from two persons in a relative manner. The E-nose is still able to recognize people, even after application of deodorant. In conclusion, this is the first report of the application of an E-nose for armpit odor recognition.

  16. Detection and classification of human body odor using an electronic nose.

    Science.gov (United States)

    Wongchoosuk, Chatchawal; Lutz, Mario; Kerdcharoen, Teerakiat

    2009-01-01

    An electronic nose (E-nose) has been designed and equipped with software that can detect and classify human armpit body odor. An array of metal oxide sensors was used for detecting volatile organic compounds. The measurement circuit employs a voltage divider resistor to measure the sensitivity of each sensor. This E-nose was controlled by in-house developed software through a portable USB data acquisition card with a principle component analysis (PCA) algorithm implemented for pattern recognition and classification. Because gas sensor sensitivity in the detection of armpit odor samples is affected by humidity, we propose a new method and algorithms combining hardware/software for the correction of the humidity noise. After the humidity correction, the E-nose showed the capability of detecting human body odor and distinguishing the body odors from two persons in a relative manner. The E-nose is still able to recognize people, even after application of deodorant. In conclusion, this is the first report of the application of an E-nose for armpit odor recognition.

  17. Three-month-old human infants use vocal cues of body size.

    Science.gov (United States)

    Pietraszewski, David; Wertz, Annie E; Bryant, Gregory A; Wynn, Karen

    2017-06-14

    Differences in vocal fundamental ( F 0 ) and average formant ( F n ) frequencies covary with body size in most terrestrial mammals, such that larger organisms tend to produce lower frequency sounds than smaller organisms, both between species and also across different sex and life-stage morphs within species. Here we examined whether three-month-old human infants are sensitive to the relationship between body size and sound frequencies. Using a violation-of-expectation paradigm, we found that infants looked longer at stimuli inconsistent with the relationship-that is, a smaller organism producing lower frequency sounds, and a larger organism producing higher frequency sounds-than at stimuli that were consistent with it. This effect was stronger for fundamental frequency than it was for average formant frequency. These results suggest that by three months of age, human infants are already sensitive to the biologically relevant covariation between vocalization frequencies and visual cues to body size. This ability may be a consequence of developmental adaptations for building a phenotype capable of identifying and representing an organism's size, sex and life-stage. © 2017 The Author(s).

  18. Machine Learning Methods for Classifying Human Physical Activity from On-Body Accelerometers

    Science.gov (United States)

    Mannini, Andrea; Sabatini, Angelo Maria

    2010-01-01

    The use of on-body wearable sensors is widespread in several academic and industrial domains. Of great interest are their applications in ambulatory monitoring and pervasive computing systems; here, some quantitative analysis of human motion and its automatic classification are the main computational tasks to be pursued. In this paper, we discuss how human physical activity can be classified using on-body accelerometers, with a major emphasis devoted to the computational algorithms employed for this purpose. In particular, we motivate our current interest for classifiers based on Hidden Markov Models (HMMs). An example is illustrated and discussed by analysing a dataset of accelerometer time series. PMID:22205862

  19. Are Caribbean reef sharks, Carcharhinus perezi, able to perceive human body orientation?

    Science.gov (United States)

    Ritter, Erich K; Amin, Raid

    2014-05-01

    The present study examines the potential capability of Caribbean reef sharks to perceive human body orientation, as well as discussing the sharks' swimming patterns in a person's vicinity. A standardized video method was used to record the scenario of single SCUBA divers kneeling in the sand and the approach patterns of sharks, combined with a control group of two divers kneeling back-to-back. When approaching a single test-subject, significantly more sharks preferred to swim outside the person's field of vision. The results suggest that these sharks are able to identify human body orientation, but the mechanisms used and factors affecting nearest distance of approach remain unclear.

  20. The point ground electrode in vicinity of the semi-spherical inhomogenity

    Directory of Open Access Journals (Sweden)

    Cvetković Nenad N.

    2005-01-01

    Full Text Available Characterization of the point ground electrode placed in the surroundings or inside of the semi-spherical earth inhomogenity and fed by low frequency (LF current using isolated earthling conductor, is presented in this paper. The ground impedance (resistance and reactance and potential distribution on the ground surface are determined. Image theory for two-layer semi conducting media, as well as for the one point electrode placed nearby or inside of the spherical body is used during the analysis.