WorldWideScience

Sample records for sem observations revealed

  1. Repetitive Observation of Coniferous Samples in ESEM and SEM

    Czech Academy of Sciences Publication Activity Database

    Tihlaříková, Eva; Neděla, Vilém

    2015-01-01

    Roč. 21, S3 (2015), s. 1695-1696 ISSN 1431-9276 R&D Projects: GA ČR(CZ) GA14-22777S; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : SEM * ESEM * biological samples * repetitive observation Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.730, year: 2015

  2. Preliminary SEM Observations on the Surface of Elastomeric Impression Materials after Immersion or Ozone Disinfection

    Science.gov (United States)

    Prombonas, Anthony; Yannikakis, Stavros; Karampotsos, Thanasis; Katsarou, Martha-Spyridoula; Drakoulis, Nikolaos

    2016-01-01

    Introduction Surface integrity of dental elastomeric impression materials that are subjected to disinfection is of major importance for the quality of the final prosthetic restorations. Aim The aim of this qualitative Scanning Electronic Microscopy (SEM) study was to reveal the effects of immersion or ozone disinfection on the surface of four dental elastomeric impression materials. Materials and Methods Four dental elastomeric impression material brands were used (two vinyl polysiloxane silicones, one polyether, and one vinyl polyether silicone). Total of 32 specimens were fabricated, eight from each impression material. Specimens were immersion (0.525% sodium hypochlorite solution or 0.3% benzalkonium chloride solution) or ozone disinfected or served as controls and examined with SEM. Results Surface degradation was observed on several speci-mens disinfected with 0.525% sodium hypochlorite solution. Similar wavy-wrinkling surface structures were observed in almost all specimens, when treated either with 0.3% benzalkonium chloride solution or ozone. Conclusion The SEM images obtained from this study revealed that both immersion disinfectants and ozone show similar impression material surface alterations. Ozone seems to be non-inferior as compared to immersion disinfectants, but superior as to environmental protection. PMID:28208993

  3. Three-dimensional intracellular structure of a whole rice mesophyll cell observed with FIB-SEM.

    Science.gov (United States)

    Oi, Takao; Enomoto, Sakiko; Nakao, Tomoyo; Arai, Shigeo; Yamane, Koji; Taniguchi, Mitsutaka

    2017-07-01

    Ultrathin sections of rice leaf blades observed two-dimensionally using a transmission electron microscope (TEM) show that the chlorenchyma is composed of lobed mesophyll cells, with intricate cell boundaries, and lined with chloroplasts. The lobed cell shape and chloroplast positioning are believed to enhance the area available for the gas exchange surface for photosynthesis in rice leaves. However, a cell image revealing the three-dimensional (3-D) ultrastructure of rice mesophyll cells has not been visualized. In this study, a whole rice mesophyll cell was observed using a focused ion beam scanning electron microscope (FIB-SEM), which provides many serial sections automatically, rapidly and correctly, thereby enabling 3-D cell structure reconstruction. Rice leaf blades were fixed chemically using the method for conventional TEM observation, embedded in resin and subsequently set in the FIB-SEM chamber. Specimen blocks were sectioned transversely using the FIB, and block-face images were captured using the SEM. The sectioning and imaging were repeated overnight for 200-500 slices (each 50 nm thick). The resultant large-volume image stacks ( x = 25 μm, y = 25 μm, z = 10-25 μm) contained one or two whole mesophyll cells. The 3-D models of whole mesophyll cells were reconstructed using image processing software. The reconstructed cell models were discoid shaped with several lobes around the cell periphery. The cell shape increased the surface area, and the ratio of surface area to volume was twice that of a cylinder having the same volume. The chloroplasts occupied half the cell volume and spread as sheets along the cell lobes, covering most of the inner cell surface, with adjacent chloroplasts in close contact with each other. Cellular and sub-cellular ultrastructures of a whole mesophyll cell in a rice leaf blade are demonstrated three-dimensionally using a FIB-SEM. The 3-D models and numerical information support the hypothesis that rice mesophyll

  4. SEM observations of particle track membrane surfaces modificated using plasma treatment

    International Nuclear Information System (INIS)

    Sartowska, B.; Buczkowski, M.; Starosta, W.

    2003-01-01

    This work presents results of scanning electron microscopy (SEM) observations of 0.4 μm membranes after plasma treatment with different parameters. The morphology changes at the surfaces and at the pore walls were observed. The character of changes in the membrane parameters according to the process conditions was determined

  5. Latent vs. Observed Variables : Analysis of Irrigation Water Efficiency Using SEM and SUR

    NARCIS (Netherlands)

    Tang, Jianjun; Folmer, Henk

    In this paper we compare conceptualising single factor technical and allocative efficiency as indicators of a single latent variable, or as separate observed variables. In the former case, the impacts on both efficiency types are analysed by means of structural equationmodeling (SEM), in the latter

  6. Analysis the fatigue using pro taper rotary instruments durin instrumentation of extrated mandibular premolars. SEM observation.

    OpenAIRE

    Siragusa, Martha; Racciatti, Gabriela; García, María

    2007-01-01

    Recibido: Marzo 2007 Aceptado: Julio 2007 Siragusa, Martha; Racciatti, Gabriela y García, María. Analysis the fatigue using pro taper rotary instruments durin instrumentation of extrated mandibular premolars. SEM observation. Electronic Journal of Endodontics Rosario [Online], Volumen 2 Número 13. [octubre 2007]. http://www.endojournal.com.ar/journal/index.php/ejer/article/view/44. ISSN 1666-6143.

  7. Sem-observation of developing plant organs using deep-frozen specimens

    NARCIS (Netherlands)

    NN,

    1982-01-01

    The SEM-observation of plant material normally requires dehydrated, dry specimens coated with carbon or metal. Unfortunately, the standard drying methods (including the critical-point-drying-technique) often cause shrinking and deformation of the specimen surface; therefore, SEMstudies on plant

  8. New airtight transfer box for SEM experiments: Application to lithium and sodium metals observation and analyses.

    Science.gov (United States)

    Stephant, Nicolas; Grissa, Rabeb; Guillou, Fanch; Bretaudeau, Mickaël; Borjon-Piron, Yann; Guillet, Jacques; Moreau, Philippe

    2018-04-18

    The surface of some materials reacts very quickly on contact with air, either because it is oxidized or because it gets humidity from the air. For the sake of original surface observation by scanning electron microscopy (SEM), we conceived an airtight transfer box to keep the samples under vacuum from the place of manufacturing to the SEM chamber. This object is designed to fit in all the models of SEM including those provided with an airlock chamber. The design is voluntarily simplified to allow the manufacturing of the object by a standard mechanical workshop. The transfer box can be easily opened by gravity inside the SEM and allows the preservation of the best vacuum inside, before opening. SEM images and energy dispersive spectroscopy (EDX) analyses of metallic lithium and sodium samples are presented prior and after exposure to the air. X-ray Photoelectron Spectroscopy (XPS) analyses of all samples are also discussed in order to investigate the chemical environments of the detected elements. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. New insights into morphological features of Hadjelia truncata (Spirurida: Habronematidae), as revealed by SEM.

    Science.gov (United States)

    Naem, Soraya; Houston, Robin S; Sentíes-Cué, Gabriel

    2013-01-01

    Hadjelia truncata (Spirurida: Habronematidae) is a nematode found in the gizzard of several avian species. However, it has been reported pathogenic only in pigeons (Columba livia), in which it causes severe ventriculitis. Scanning electron microscopy (SEM) was used to study the morphological aspects of adult worms of this nematode in detail. Males and females measured 6.5-9 and 12-16.5 mm, respectively. The bodies were straight with moderate uniform thickness in both males and females, narrowing at the anterior end. The cuticle was striated transversely. The mouth was surrounded by two lateral trilobed lips, and the dorsal and ventral interlabia were present. The two cephalic papillae were present on each side lodged just behind the upper and lower bases of each lip. Around the mouth, a large amphid was seen on each lip. At the anterior end of both male and female worms, an excretory pore on the ventral side and a pair of lateral cervical papillae were observed. In the female, the vulva was located at the anterior end of the body. The lips of the vulva protruded above the body surface, and the bluntly rounded posterior end showed an anal pore and two subterminal phasmids. The posterior end of the males curved ventrally, with large caudal alae supported by four pairs of stalked precloacal papillae, a single medial precloacal papilla, two pairs of postcloacal papillae, and a cluster of small papillae on the caudal extremity. Spicules were unequal and dissimilar.

  10. Optimization study of direct morphology observation by cold field emission SEM without gold coating.

    Science.gov (United States)

    He, Dan; Fu, Cheng; Xue, Zhigang

    2018-06-01

    Gold coating is a general operation that is generally applied on non-conductive or low conductive materials, during which the morphology of the materials can be examined by scanning electron microscopy (SEM). However, fatal deficiencies in the materials can result in irreversible distortion and damage. The present study directly characterized different low conductive materials such as hydroxyapatite, modified poly(vinylidene fluoride) (PVDF) fiber, and zinc oxide nanopillar by cold field emission scanning electron microscopy (FE-SEM) without a gold coating. According to the characteristics of the low conductive materials, various test conditions, such as different working signal modes, accelerating voltages, electron beam spots, and working distances, were characterized to determine the best morphological observations of each sample. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Continuous observation of cavity growth and coalescence by creep-fatigue tests in SEM

    International Nuclear Information System (INIS)

    Arai, Masayuki; Ogata, Takashi; Nitta, Akito

    1995-01-01

    Structural components operating at high temperatures in power plants are subjected to interaction of thermal fatigue and creep which results in creep-fatigue damage. In evaluating the life of those components, it is important to understand microscopic damage evolution under creep-fatigue conditions. In this study, static creep and creep-fatigue tests with tensile holdtime were conducted on SUS304 stainless steel by using a high-temperature fatigue machine combined with a scanning electron microscope (SEM), and cavity growth and coalescence behaviors on surface grain boundaries were observed continuously by the SEM. Quantitative analysis of creep cavity growth based on the observation was made for comparison with theoretical growth models. As a result, it was found that grain boundary cavities nucleate at random and grow preferentially on grain boundaries in a direction almost normal to the stress axis. Under the creep condition, the cavities grow monotonously on grain boundaries while they remain the elliptical shape. On the other hand, under the creep-fatigue condition the cavities grow with an effect of local strain distribution around the grain boundary due to cyclic loading and the micro cracks of one grain-boundary length were formed by coalescence of the cavities. Also, cavity nucleation and growth rates for creep-fatigue were more rapid than those for static creep and the constrained cavity growth model coincided well with the experimental data for creep. (author)

  12. Non-oxidative and oxidative torrefaction characterization and SEM observations of fibrous and ligneous biomass

    International Nuclear Information System (INIS)

    Chen, Wei-Hsin; Lu, Ke-Miao; Lee, Wen-Jhy; Liu, Shih-Hsien; Lin, Ta-Chang

    2014-01-01

    Highlights: • Non-oxidative and oxidative torrefaction of biomass is studied. • Two fibrous biomasses and two ligneous biomasses are tested. • SEM observations of four biomasses are provided. • Fibrous biomass is more sensitive to O 2 concentration than ligneous biomass. • The performance of non-oxidative torrefaction is better than that of oxidative torrefaction. - Abstract: Oxidative torrefaction is a method to reduce the operating cost of upgrading biomass. To understand the potential of oxidative torrefaction and its impact on the internal structure of biomass, non-oxidative and oxidative torrefaction of two fibrous biomass materials (oil palm fiber and coconut fiber) and two ligneous ones (eucalyptus and Cryptomeria japonica) at 300 °C for 1 h are studied and compared with each other. Scanning electron microscope (SEM) observations are also performed to explore the impact of torrefaction atmosphere on the lignocellulosic structure of biomass. The results indicate that the fibrous biomass is more sensitive to O 2 concentration than the ligneous biomass. In oxidative torrefaction, an increase in O 2 concentration decreases the solid yield. The energy yield is linearly proportional to the solid yield, which is opposite to the behavior of non-oxidative torrefaction. The performance of non-oxidative torrefaction is better than that of oxidative torrefaction. As a whole, ligneous biomass can be torrefied in oxidative environments at lower O 2 concentrations, whereas fibrous biomass is more suitable for non-oxidative torrefaction

  13. SEM-EDS Observation of Structure Changes in Synthetic Zeolites Modified for CO2 Capture Needs

    Science.gov (United States)

    Wdowin, Magdalena; Panek, Rafal; Franus, Wojciech

    Carbon dioxide is the main greenhouse gas and its amount still increase in the atmosphere. Air pollution and greenhouse effect caused by CO2 emission have become a major threat to the environment on a global scale. Carbon dioxide sequestration (i.e. capture and consequently geological storage) is the key strategy within the portfolio of actions to reduce CO2 emission to the atmosphere. The most costly stage is capture of CO2, therefore there is a need to search new solutions of this technology. For this purpose it was examined Na-X synthetic zeolites, that were silver and PEI (polyethyleneimine) activated. SEM-EDS investigation enable to find a changes in structure of this materials after treatment. Where, as a result of silver activation from EDS analysis it is seen that Ag occur in Na-X structure, what indicate a substitution of Ag2+ for Na+ ions in crystal lattice. Analysing wt% the EDS analysis has shown that zeolite Na-X after silver impregnation becomes Ag-X zeolite. For Na-X-PEI activated it is observed a distinct organic compound in the form of coatings on Na-X crystals causing a sealing of pores in tested zeolite. Further examination of these materials concern determination of surface properties and experiments of CO2 sorption. But SEM-EDS analysis enable to determine the extent of activation, what is very important in determination of optimal conditions for such treatment in order to obtain better sorbent of CO2.

  14. Observation of interactions between hydrophilic ionic liquid and water on wet agar gels by FE-SEM and its mechanism

    International Nuclear Information System (INIS)

    Takahashi, Chisato; Shirai, Takashi; Fuji, Masayoshi

    2012-01-01

    Highlights: ► The mechanism of SEM observation of agar gel using ionic liquid was investigated. ► Weak hydrogen bond between ionic liquid and water exist even under vacuum condition. ► Ionic liquid binding ability with water is useful for observing wet material using FE-SEM. ► We could optimize the water concentrations of sample of IL and wet material mixtures. ► SEM observation of fine morphology of agar gel in optimum water content. - Abstract: In the present study, an attempt is made to understand the mechanism of field emission electron microscopy (FE-SEM) observation of wet agar gel using a typical hydrophilic ionic liquid (IL) 1-butyl-3-methylimidazolium tetrafluoroborate; [BMIM][BF 4 ]. The IL interaction with water molecules within agar gel during sample preparation condition for FE-SEM observation was investigated using Raman spectroscopy. Results showed that water molecules within agar gel form weak hydrogen bond such as BF 4 − ⋯HOH⋯BF 4 − by interaction with BF 4 − of IL, and, it remained stable even under vacuum condition at 60 °C, 24 h. This interaction was found to be helpful for IL displacement of the water molecules within agar gel. From this study, it was found that the exact morphology of gel materials in FE-SEM condition can be observed by optimization of water concentrations of IL and gel mixtures. Thus, using IL, agar gel or any other material under wet condition can be observed without drying in FE-SEM chamber, and, present result gives an insight to the mechanism of FE-SEM observation of agar gel using IL without any conducting coating.

  15. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    Science.gov (United States)

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  16. Methods for Additive Hydration Allowing Observation of Fully Hydrated State of Wet Samples in Environmental SEM

    Czech Academy of Sciences Publication Activity Database

    Neděla, Vilém

    2007-01-01

    Roč. 70, č. 2 (2007), s. 95-100 ISSN 1059-910X R&D Projects: GA ČR(CZ) GA102/05/0886; GA AV ČR KJB200650602 Institutional research plan: CEZ:AV0Z20650511 Keywords : agar * natural structure * biological specimens * environmental SEM Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.644, year: 2007

  17. In-situ SEM observation on fracture behavior of austempered silicon alloyed steel

    Directory of Open Access Journals (Sweden)

    Chen Xiang

    2009-08-01

    Full Text Available Crack initiation, propagation and microfracture processes of austempered high silicon cast steel have been investigated by using an in-situ tensile stage installed inside a scanning electron microscope chamber. It is revealed that micro cracks always nucleate at the yielding near imperfections and the boundary of matrix-inclusions due to the stress concentration. There are four types of crack propagations in the matrix: crack propagates along the boundary of two clusters of bainitic ferrite; crack propagates along the boundary of ferrite朼ustenite in bainitic ferrite laths; crack propagates into bainitic ferrite laths; crack nucleates and propagates in the high carbon brittle plate shape martensite which is transformed from some blocky retained austenite due to plastic deformation. Based on the observation and analysis of microfracture processes, a schematic diagram of the crack nucleation and propagation process of high silicon cast steel is proposed

  18. Observation particle morphology of colloidal system by conventional SEM with an improved specimen preparation technique.

    Science.gov (United States)

    Xu, Jing; Hou, Zhaosheng; Yuan, Xiaojiao; Guo, Hong

    2011-08-01

    On the basis of our previous report that polymer emulsion with different viscosity can be investigated by conventional scanning electron microscopy (SEM), we have developed an improved specimen preparation technique for obtaining particle morphology and size of colloidal silver, collagen, glutin, and polymer microspheres. In this study, we expect to provide a means for charactering the three-dimensional surface microstructure of colloidal particles. Dilution of the samples with appropriate volatile solvent like ethanol is effective for SEM specimen preparation. At a proper ratio between sample and ethanol, the colloidal particles are dispersed uniformly in ethanol and then deposited evenly on the substrate. Different drying methods are studied to search a proper drying condition, in which the small molecule solvent is removed without destroying the natural particle morphology. And the effects of ethanol in the specimen preparation process are described by analyzing the physicochemical properties of ethanol. The specimen preparation technique is simple and can be achieved in common laboratory for charactering the particle morphology of colloidal system. Copyright © 2010 Wiley-Liss, Inc.

  19. Surface ultrastuctures of the human laryngeal mucosa - observation by an newly developed technique of SEM cinematography

    International Nuclear Information System (INIS)

    Ohyama, M.; Ohno, I.; Fujita, T.; Adachi, K.

    1981-01-01

    With the newly-developed techniques of SEM cinematography, surface ultrastructures of the human normal and pathological laryngeal mucosa were demonstrated. The high specialization of the laryngeal mucosa with its marked regional differences stresses the fact that even the squamous epithelium and nonciliated epithelium may play a role of utmost importance. All specimens were obtained after laryngectomy from 10 patients affected by laryngeal cancer which had been treated with or without preoperative irradiation of Lineac in total doses of 3,500-4,500 rad. Special attention was paid to the occurrence of microvilli and microplicae in the normal and pathological mucosa of the larynx, and their morphological and physiological significances were discussed briefly. (Auth.)

  20. Graphene-supporting films and low-voltage STEM in SEM toward imaging nanobio materials without staining: Observation of insulin amyloid fibrils.

    Science.gov (United States)

    Ogawa, Takashi; Gang, Geun Won; Thieu, Minh Thu; Kwon, Hyuksang; Ahn, Sang Jung; Ha, Tai Hwan; Cho, Boklae

    2017-05-01

    Utilization of graphene-supporting films and low-voltage scanning transmission electron microscopy (LV-STEM) in scanning electron microscopy (SEM) is shown to be an effective means of observing unstained nanobio materials. Insulin amyloid fibrils, which are implicated as a cause of type II diabetes, are formed in vitro and observed without staining at room temperature. An in-lens cold field-emission SEM, equipped with an additional homemade STEM detector, provides dark field (DF)-STEM images in the low energy range of 5-30keV, together with secondary electron (SE) images. Analysis based on Lenz's theory is used to interpret the experimental results. Graphene films, where the fibrils are deposited, reduce the background level of the STEM images compared with instances when conventional amorphous carbon films are used. Using 30keV, which is lower than that for conventional TEM (100-300keV), together with low detection angles (15-55mrad) enhances the signals from the fibrils. These factors improve image quality, which enables observation of thin fibrils with widths of 7-8nm. STEM imaging clearly reveals a twisted-ribbon structure of a fibril, and SE imaging shows an emphasized striped pattern of the fibril. The LV-STEM in SEM enables acquisition of two types of images of an identical fibril in a single instrument, which is useful for understanding the structure. This study expands the application of SEM to other systems of interest, which is beneficial to a large number of users. The method in this study can be applied to the observation of various nanobio materials and analysis of their native structures, thus contributing to research in materials and life sciences. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Abnormal gas-liquid-solid phase transition behaviour of water observed with in situ environmental SEM.

    Science.gov (United States)

    Chen, Xin; Shu, Jiapei; Chen, Qing

    2017-04-24

    Gas-liquid-solid phase transition behaviour of water is studied with environmental scanning electron microscopy for the first time. Abnormal phenomena are observed. At a fixed pressure of 450 Pa, with the temperature set to -7 °C, direct desublimation happens, and ice grows continuously along the substrate surface. At 550 Pa, although ice is the stable phase according to the phase diagram, metastable liquid droplets first nucleate and grow to ~100-200 μm sizes. Ice crystals nucleate within the large sized droplets, grow up and fill up the droplets. Later, the ice crystals grow continuously through desublimation. At 600 Pa, the metastable liquid grows quickly, with some ice nuclei floating in it, and the liquid-solid coexistence state exists for a long time. By lowering the vapour pressure and/or increasing the substrate temperature, ice sublimates into vapour phase, and especially, the remaining ice forms a porous structure due to preferential sublimation in the concave regions, which can be explained with surface tension effect. Interestingly, although it should be forbidden for ice to transform into liquid phase when the temperature is well below 0 °C, liquid like droplets form during the ice sublimation process, which is attributed to the surface tension effect and the quasiliquid layers.

  2. Antimicrobial Potential and Chemical Characterization of Serbian Liverwort (Porella arboris-vitae: SEM and TEM Observations

    Directory of Open Access Journals (Sweden)

    Amit Kumar Tyagi

    2013-01-01

    Full Text Available The chemical composition of Porella arboris-vitae extracts was determined by solid phase microextraction, gas chromatography-mass spectrometry (SPME GC-MS, and 66 constituents were identified. The dominant compounds in methanol extract of P. arboris-vitae were β-caryophyllene (14.7%, α-gurjunene (10.9%, α-selinene (10.8%, β-elemene (5.6%, γ-muurolene (4.6%, and allo-aromadendrene (4.3% and in ethanol extract, β-caryophyllene (11.8%, α-selinene (9.6%, α-gurjunene (9.4%, isopentyl alcohol (8.8%, 2-hexanol (3.7%, β-elemene (3.7%, allo-aromadendrene (3.7%, and γ-muurolene (3.3% were the major components. In ethyl acetate extract of P. arboris-vitae, undecane (11.3%, β-caryophyllene (8.4%, dodecane (6.4%, α-gurjunene (6%, 2-methyldecane (5.1%, hemimellitene (4.9%, and D-limonene (3.9% were major components. The antimicrobial activity of different P. arboris-vitae extracts was evaluated against selected food spoilage microorganisms using microbroth dilution method. The Minimal Inhibitory Concentration (MIC varied from 0.5 to 1.5 mg/mL and 1.25 to 2 mg/mL for yeast and bacterial strains, respectively. Significant morphological and ultrastructural alterations due to the effect of methanolic and ethanolic P. arboris-vitae extracts on S. Enteritidis have also been observed by scanning electron microscope and transmission electron microscope, respectively. The results provide the evidence of antimicrobial potential of P. arboris-vitae extracts and suggest its potential as natural antimicrobial agents for food preservation.

  3. Attempt of correlative observation of morphological synaptic connectivity by combining confocal laser-scanning microscope and FIB-SEM for immunohistochemical staining technique.

    Science.gov (United States)

    Sonomura, Takahiro; Furuta, Takahiro; Nakatani, Ikuko; Yamamoto, Yo; Honma, Satoru; Kaneko, Takeshi

    2014-11-01

    Ten years have passed since a serial block-face scanning electron microscopy (SBF-SEM) method was developed [1]. In this innovative method, samples were automatically sectioned with an ultramicrotome placed inside a scanning electron microscope column, and the block surfaces were imaged one after another by SEM to capture back-scattered electrons. The contrast-inverted images obtained by the SBF-SEM were very similar to those acquired using conventional TEM. SFB-SEM has made easy to acquire image stacks of the transmission electron microscopy (TEM) in the mesoscale, which is taken with the confocal laser-scanning microcopy(CF-LSM).Furthermore, serial-section SEM has been combined with the focused ion beam (FIB) milling method [2]. FIB-incorporated SEM (FIB-SEM) has enabled the acquisition of three-dimensional images with a higher z-axis resolution com- pared to ultramicrotome-equipped SEM.We tried immunocytochemistry for FIB-SEM and correlated this immunoreactivity with that in CF-LSM. Dendrites of neurons in the rat neostriatum were visualized using a recombinant viral vector. Moreover, the thalamostriatal afferent terminals were immunolabeled with Cy5 fluorescence for vesicular glutamate transporter 2 (VGluT2). After detection of the sites of terminals apposed to the dendrites by using CF-LSM, GFP and VGluT2 immunoreactivities were further developed for EM by using immunogold/silver enhancement and immunoperoxidase/diaminobenzidine (DAB) methods, respectively.We showed that conventional immuno-cytochemical staining for TEM was applicable to FIB-SEM. Furthermore, several synaptic contacts, which were thought to exist on the basis of CF-LSM findings, were confirmed with FIB-SEM, revealing the usefulness of the combined method of CF-LSM and FIB-SEM. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. TEM and SEM observation of uranium induced renal necrosis and the result of chelates treatment on rats

    International Nuclear Information System (INIS)

    Sun Shiquan; Li Baoxing; Lai Chixiang; You Zhanyun

    1987-01-01

    The TEM (transmission electron microscope) and SEM (scanning electron microscope) observation of uranium induced renal necrosis and the result of chelates treatment on rats are reported. Ultrastructural changes in kidney related with the impairment of intracellular fluid transportation can be found after acute uranium intoxication in rats, such as: condensation and swelling of mitochondria, matrix edema, dilatation of intercellular space, disappearance of basal folds, thickening of basal web, intensification of basal lamina of the proximal convoluted tubule epithelium cells, and foot processes swelling, diminishing of endothelium fenestrae of the renal glomerulus. Heavy metal chelates DTPA and H-73-10 treatment may result in intracellular fluid accumulation and condensed grannule formation in lysosome. Treatment with these chelates in the critical stage of uranium intoxication may accelerate the necrosis instead of diminishing. This may be related to the augment of the load of lysosome and intracellular system of fluid transportation

  5. SEM Anthology

    Science.gov (United States)

    Rodgers, Michelle; Zimar, Heather

    2004-01-01

    The "SEM Anthology" is a compilation of articles by more than 30 enrollment management professionals from a variety of institutions across the country. This collection, which has appeared in SEM Monthly over the past year, chronicles Strategic Enrollment Management efforts at campuses nationwide. The book illustrates the successes and challenges…

  6. Poly(vinylidene fluoride)-based ion track membranes with different pore diameters and shapes. SEM observations and conductometric analysis

    International Nuclear Information System (INIS)

    Nuryanthi, Nunung; Yamaki, Tetsuya; Koshikawa, Hiroshi; Asano, Masaharu; Enomoto, Kazuyuki; Sawada, Shin-ichi; Maekawa, Yasunari; Voss, Kay-Obbe; Trautmann, Christina; Neumann, Reinhard

    2010-01-01

    Poly(vinylidene fluoride) (PVDF) membranes with conical and cylindrical nanopores were prepared in a controlled manner by the ion-track technique, which involved heavy-ion beam irradiation and subsequent alkaline etching. The etching behavior mainly depended on the energy deposition of the ion beams, and thus its depth distribution, estimated by theoretical simulation, was successfully applied to control the shapes and diameters of the etched pores. Scanning electron microscopy (SEM) and electrolytic conductometry provided an insight into the critical experimental parameters. Interestingly, applying a higher voltage to the conductometry cell promoted track etching up to breakthrough probably because electrophoretic migration of the dissolved products occurred out of each pore. (author)

  7. A ‘NanoSuit’ surface shield successfully protects organisms in high vacuum: observations on living organisms in an FE-SEM

    Science.gov (United States)

    Takaku, Yasuharu; Suzuki, Hiroshi; Ohta, Isao; Tsutsui, Takami; Matsumoto, Haruko; Shimomura, Masatsugu; Hariyama, Takahiko

    2015-01-01

    Although extremely useful for a wide range of investigations, the field emission scanning electron microscope (FE-SEM) has not allowed researchers to observe living organisms. However, we have recently reported that a simple surface modification consisting of a thin extra layer, termed ‘NanoSuit’, can keep organisms alive in the high vacuum (10−5 to 10−7 Pa) of the SEM. This paper further explores the protective properties of the NanoSuit surface-shield. We found that a NanoSuit formed with the optimum concentration of Tween 20 faithfully preserves the integrity of an organism's surface without interfering with SEM imaging. We also found that electrostatic charging was absent as long as the organisms were alive, even if they had not been coated with electrically conducting materials. This result suggests that living organisms possess their own electrical conductors and/or rely on certain properties of the surface to inhibit charging. The NanoSuit seems to prolong the charge-free condition and increase survival time under vacuum. These findings should encourage the development of more sophisticated observation methods for studying living organisms in an FE-SEM. PMID:25631998

  8. New data on the morphology of some Far-Eastern species of Rhabdochona (Nematoda: Rhabdochonidae), as revealed by SEM observations

    Czech Academy of Sciences Publication Activity Database

    Moravec, František; Ermolenko, A. V.; Besprozvannykh, V. V.; Scholz, Tomáš

    2012-01-01

    Roč. 59, č. 3 (2012), s. 195-208 ISSN 0015-5683 R&D Projects: GA ČR GBP505/12/G112 Institutional support: RVO:60077344 Keywords : parasitic nematodes * Rhabdochona * freshwater fish * Chanodichthys * Culter * Hemibarbus * Russian Far East Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 2.515, year: 2012 http://folia.paru.cas.cz/detail.php?id=22067

  9. HERSCHEL OBSERVATIONS REVEAL ANOMALOUS MOLECULAR ABUNDANCES TOWARD THE GALACTIC CENTER

    Energy Technology Data Exchange (ETDEWEB)

    Sonnentrucker, P. [Space Telescope Science Institute, Baltimore, MD 21218 (United States); Neufeld, D. A.; Indriolo, N. [Physics and Astronomy Department, Johns Hopkins University, Baltimore, MD 21218 (United States); Gerin, M.; De Luca, M. [LERMA-LRA, UMR 8112 du CNRS, Observatoire de Paris, Ecole Normale Superieure, UPMC and UCP, 24 rue Lhomond, F-75231, Paris Cedex 05 (France); Lis, D. C. [Astronomy Department, California Institute of Technology, Pasadena, CA 91125 (United States); Goicoechea, J. R., E-mail: sonnentr@stsci.edu [Centro de Astrobiologia, CSIC/INTA, E-28850, Madrid (Spain)

    2013-01-20

    We report the Herschel detections of hydrogen fluoride (HF) and para-water (p-H{sub 2}O) in gas intercepting the sight lines to two well-studied molecular clouds in the vicinity of the Sgr A complex: G-0.02-0.07 (the {sup +}50 km s{sup -1} cloud{sup )} and G-0.13-0.08 (the {sup +}20 km s{sup -1} cloud{sup )}. Toward both sight lines, HF and water absorption components are detected over a wide range of velocities covering {approx}250 km s{sup -1}. For all velocity components with V{sub LSR} > -85 km s{sup -1}, we find that the HF and water abundances are consistent with those measured toward other sight lines probing the Galactic disk gas. The velocity components with V{sub LSR} {<=} -85 km s{sup -1}, which are known to trace gas residing within {approx}200 pc of the Galactic center, however, exhibit water vapor abundances with respect to HF at least a factor three higher than those found in the Galactic disk gas. Comparison with CH data indicates that our observations are consistent with a picture where HF and a fraction of the H{sub 2}O absorption arise in diffuse molecular clouds showing Galactic disk-like abundances while the bulk of the water absorption arises in warmer (T {>=} 400 K) diffuse molecular gas for V{sub LSR} {<=} -85 km s{sup -1}. This diffuse Interstellar Medium (ISM) phase has also been recently revealed through observations of CO, HF, H{sup +}{sub 3}, and H{sub 3}O{sup +} absorption toward other sight lines probing the Galactic center inner region.

  10. SEM observation of grain boundary structures in quartz-iron oxide rocks deformed at intermediate metamorphic conditions

    Directory of Open Access Journals (Sweden)

    Leonardo Lagoeiro

    2011-09-01

    Full Text Available Several studies have demonstrated the effect of a second phase on the distribution of fluid phase and dissolution of quartz grains. However, as most observations came from aggregates deformed under hydrostatic stress conditions and mica-bearing quartz rocks, 3-D distribution of pores on quartz-quartz (QQB and quartz-hematite boundaries (QHB has been studied. Several fracture surfaces oriented according to finite strain ellipsoid were analyzed. The pore distribution characterizes the porosity and grain shape as highly anisotropic, which results from the nature and orientation of boundaries. QHB have physical/chemical properties very different from QQB, once the hematite plates have strong effect on wetting behavior of fluid, likewise micas in quartzites. They are pore-free flat surfaces, normal to compression direction, suggesting that they were once wetted with a continuous fluid film acting as faster diffusion pathway. At QQB, the pores are faceted, isolated, close to its edges reflecting the crystallographic control and an interconnected network of fluid along grain junctions. The QQB facing the extension direction are sites of fluid concentration. As consequence, the anisotropic dissolution and grain growth were responsible for the formation of hematite plates and tabular quartz grains significantly contributing for the generation of the foliation observed in the studied rocks.Muitos estudos têm demonstrado o efeito de uma segunda fase sobre a distribuição de fase fluida e dissolução de grãos de quartzo. Entretanto, como a maioria das observações vêm de agregados deformados sob condições de tensão hidrostática e em rochas quartzosas ricas em mica, a distribuição 3D de poros e bordas quartzo-quartzo (BQQ e quartzo-hematita (BQH tem sido estudada. Várias superfícies de fraturas orientadas segundo o elipsóide de deformação finita foram analisadas. A distribuição dos poros caracteriza a porosidade e a forma dos grãos como

  11. In Situ SEM Observations of Fracture Behavior of Laser Welded-Brazed Al/Steel Dissimilar Joint

    Science.gov (United States)

    Xia, Hongbo; Tan, Caiwang; Li, Liqun; Ma, Ninshu

    2018-03-01

    Laser welding-brazing of 6061-T6 aluminum alloy to DP590 dual-phase steel with Al-Si12 flux-cored filler wire was performed. The microstructure at the brazing interface was characterized. Fracture behavior was observed and analyzed by in situ scanning electron microscope. The microstructure of the brazing interface showed that inhomogeneous intermetallic compounds formed along the thickness direction, which had a great influence on the crack initiation and propagation. In the top region, the reaction layer at the interface consisted of scattered needle-like Fe(Al,Si)3 and serration-shaped Fe1.8Al7.2Si. In the middle region, the compound at the interface was only serration-shaped Fe1.8Al7.2Si. In the bottom region, the interface was composed of lamellar-shaped Fe1.8Al7.2Si. The cracks were first detected in the bottom region and propagated from bottom to top along the interface. At the bottom region, the crack initiated and propagated along the Fe1.8Al7.2Si/weld seam interface during the in situ tensile test. When the crack propagated into the middle region, a deflection of crack propagation appeared. The crack first propagated along the steel/Fe1.8Al7.2Si interface and then moved along the weld seam until the failure of the joint. The tensile strength of the joint was 146.5 MPa. Some micro-cracks were detected at Fe(Al,Si)3 and the interface between the steel substrate and Fe(Al,Si)3 in the top region while the interface was still connected.

  12. Backscattered electron SEM imaging of resin sections from plant specimens: observation of histological to subcellular structure and CLEM.

    Science.gov (United States)

    Rizzo, N W; Duncan, K E; Bourett, T M; Howard, R J

    2016-08-01

    We have refined methods for biological specimen preparation and low-voltage backscattered electron imaging in the scanning electron microscope that allow for observation at continuous magnifications of ca. 130-70 000 X, and documentation of tissue and subcellular ultrastructure detail. The technique, based upon early work by Ogura & Hasegawa (1980), affords use of significantly larger sections from fixed and resin-embedded specimens than is possible with transmission electron microscopy while providing similar data. After microtomy, the sections, typically ca. 750 nm thick, were dried onto the surface of glass or silicon wafer and stained with heavy metals-the use of grids avoided. The glass/wafer support was then mounted onto standard scanning electron microscopy sample stubs, carbon-coated and imaged directly at an accelerating voltage of 5 kV, using either a yttrium aluminum garnet or ExB backscattered electron detector. Alternatively, the sections could be viewed first by light microscopy, for example to document signal from a fluorescent protein, and then by scanning electron microscopy to provide correlative light/electron microscope (CLEM) data. These methods provide unobstructed access to ultrastructure in the spatial context of a section ca. 7 × 10 mm in size, significantly larger than the typical 0.2 × 0.3 mm section used for conventional transmission electron microscopy imaging. Application of this approach was especially useful when the biology of interest was rare or difficult to find, e.g. a particular cell type, developmental stage, large organ, the interface between cells of interacting organisms, when contextual information within a large tissue was obligatory, or combinations of these factors. In addition, the methods were easily adapted for immunolocalizations. © 2015 The Author. Journal of Microscopy published by John Wiley & Sons, Ltd on behalf of the Royal Microscopical Society.

  13. Evaluation of Detrimental Effects on Mechanical Properties of Zry-4 Due to Hydrogen Absorption by means of Scanning Electron Microscopy (SEM) In-Situ Observation of Crack Propagation

    International Nuclear Information System (INIS)

    Fernandez, L; Fernandez, G.E; Bertolino, G; Meyer, G

    2001-01-01

    The study of mechanical properties degradation of zirconium alloys due to hydrides assumes fundamental importance in the nuclear industry.During normal nuclear reactors operation, structural parts absorbed hydrogen generated from radiolysis of water, causing detrimental effects on mechanical properties.As a consequence, these materials are easily cracked in the presence of mechanical solicitation due to loss of ductility of the hydride-phase.The presence of cracks indicates fracture mechanic as the most suitable methodology in the study of mechanical properties degradation.In this work we used the crack tip opening displacement (CTOD) criteria to evaluate the detrimental effects on mechanical properties with the observation in SEM of crack propagation.The samples used were SEN (B) of Zry-4 and cathodic homogenous charged with hydrogen concentrations lower than 400 ppm

  14. ALICE’s wonderland reveals the heaviest antimatter ever observed

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    Producing and observing antiparticles is part of everyday life for many physics laboratories around the world, including CERN. However, recreating and observing the anti-nuclei of complex atoms is a much more difficult task. Analysing data collected in a run of just one month, ALICE has recently found evidence of the formation of four anti-nuclei of Helium 4, the heaviest antimatter ever created in a laboratory.   The STAR experiment at RHIC came first and published the result in March: they presented evidence of 18 anti-nuclei of Helium 4 collected over several years of data taking. “ALICE came second but it's amazing to see how fast the results came,” exclaims Paolo Giubellino, the experiment’s spokesperson. “We were able to confirm the observation of 4He anti-nuclei with data collected in November 2010.” Scientists agree on the fact that antimatter was created in the Big Bang together with matter. However, today we do not observe antimatter outsid...

  15. Eye movements reveal epistemic curiosity in human observers.

    Science.gov (United States)

    Baranes, Adrien; Oudeyer, Pierre-Yves; Gottlieb, Jacqueline

    2015-12-01

    Saccadic (rapid) eye movements are primary means by which humans and non-human primates sample visual information. However, while saccadic decisions are intensively investigated in instrumental contexts where saccades guide subsequent actions, it is largely unknown how they may be influenced by curiosity - the intrinsic desire to learn. While saccades are sensitive to visual novelty and visual surprise, no study has examined their relation to epistemic curiosity - interest in symbolic, semantic information. To investigate this question, we tracked the eye movements of human observers while they read trivia questions and, after a brief delay, were visually given the answer. We show that higher curiosity was associated with earlier anticipatory orienting of gaze toward the answer location without changes in other metrics of saccades or fixations, and that these influences were distinct from those produced by variations in confidence and surprise. Across subjects, the enhancement of anticipatory gaze was correlated with measures of trait curiosity from personality questionnaires. Finally, a machine learning algorithm could predict curiosity in a cross-subject manner, relying primarily on statistical features of the gaze position before the answer onset and independently of covariations in confidence or surprise, suggesting potential practical applications for educational technologies, recommender systems and research in cognitive sciences. With this article, we provide full access to the annotated database allowing readers to reproduce the results. Epistemic curiosity produces specific effects on oculomotor anticipation that can be used to read out curiosity states. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Ao leitor sem medo

    Directory of Open Access Journals (Sweden)

    José Eisenberg

    2000-05-01

    Full Text Available O texto resenha Ao leitor sem medo, de Renato Janine Ribeiro (Belo Horizonte, UFMG, 1999.This text is a review of Ao leitor sem medo by Renato Janine Ribeiro (Belo Horizonte, UFMG, 1999

  17. Arterial supply and venous drainage of the choroid plexus of the human lateral ventricle in the prenatal period as revealed by vascular corrosion casts and SEM.

    Science.gov (United States)

    Zagórska-Swiezy, K; Litwin, J A; Gorczyca, J; Pityński, K; Miodoński, A J

    2008-08-01

    The topography of the arterial supply and venous drainage was visualised by corrosion casting and scanning electron microscopy in the human foetal (20 weeks) choroid plexus of the lateral ventricle. Although secondary villi were not yet present at that developmental stage, the topography of the large arteries and veins almost fully corresponded to that described in adult individuals. The only major difference observed was a lack of the typical tortuosity of the lateral branch of the anterior choroidal artery and of the superior choroidal vein, which probably develops during further expansion of the vascular system associated with the formation of secondary villi.

  18. Advanced SEM imaging

    International Nuclear Information System (INIS)

    Joy, D. C.; Newbury, D. E.

    1998-01-01

    The scanning electron microscope (SEM) represents the most promising tool for metrology, defect review, and for the analysis of ULSI structures, but both fundamental problems such as electron-solid interactions, and practical considerations such as electron-optical constraints, are now setting a limit to performance. This paper examines the directions in which an advanced SEM might be developed to overcome these constraints. The SEM also offers considerable promise as a tool for the high spatial resolution X-ray microanalysis, especially for those situations where a thin cross-section is not practical and first surface analysis is required. The ways in which this capability can be incorporated in an advanced SEM are examined

  19. Advanced SEM imaging

    International Nuclear Information System (INIS)

    Joy, D.C.; Newbury, D.E.; Newbury, D.E.

    1998-01-01

    The scanning electron microscope (SEM) represents the most promising tool for metrology, defect review, and for the analysis of ULSI structures, but both fundamental problems such as electron-solid interactions, and practical considerations such as electron-optical constraints, are now setting a limit to performance. This paper examines the directions in which an advanced SEM might be developed to overcome these constraints. The SEM also offers considerable promise as a tool for the high spatial resolution X-ray microanalysis, especially for those situations where a thin cross-section is not practical and first surface analysis is required. The ways in which this capability can be incorporated in an advanced SEM are examined. copyright 1998 American Institute of Physics

  20. Structure and Novel Biomineralization of Mnemiopsis Leidyi and Beroe Ovata Lithocyte Concretions (lcs) as Revealed by Polarization Lc-Pol Scanning Electron Microscopy (sem) and Electron Dispersion Spectroscopy (eds)

    Science.gov (United States)

    Moss, A.

    2016-02-01

    Ctenophore statocysts have multicellular statoliths borne on the tips of balancer compound cilia (Curr. Biol. 24:R951; Biol. Bull. 227:7). Lithocyte concretions (LCs) were prepared by three methods: 1) statocysts were microsurgically collected and washed w/0.2 µm filtered sea water (FSW), followed by 5 diH2O rinses in a deep well dish (DWD); 2) statocysts were treated with 50% Chlorox/FSW to release the statolith/LCs; 3) statocysts were fixed in 2.5% glutaraldehyde or 1% paraformaldehyde-2.5% glutaraldehyde in 10 mM pH 7.8 HEPES-buffered FSW, and statoliths and LCs microsurgically released. LCs for SEM were glued to stubs, C-stabilized and Pt-coated to a thickness of 8 nm and viewed at 10 kVe. LCs for EDS were applied to carbon tape on aluminum stubs and analyzed by EDS at 3 and 10 kVe. SEM and EDS were performed on a Zeiss Supra 40 VP equipped with an EDS detector controlled by INCA software (Oxford). Results were compared against compounds of known elemental composition. LCs examined by LC-POL revealed no birefringence (BR). LCs viewed by SEM were either a lumpy mass (M. leidyi) or smooth ellipsoid (B. ovata). LCs on carbon tape typically shattered and released overlapping, layered, multi-oriented crystals. EDS of LC crystals from both species collected by all methods lacked Ca, Mn and Mg. Predominant elements were Na, K, O and S in ratios suggesting that LCs contain mixed sodium/potassium sulfates. The unique composition of ctenophore statoliths may have been critical for the 600+ million years persistence of these organisms (J. exp. Biol. 218:592) including survival through multiple global extinctions and related ocean acidifications. Thanks to L. Kerr, R. Oldenbourg, S. Mehta, A. Verma, M. Tran, A. Kuzirian and S. Tamm for stimulating discussion and technical advice. EDS stds compounds were curtesy of L. Amaral-Zettler, J. Huber and K. Gribble (Bay Paul Center/MBL). Funding: AU PIL Program, NSF-EPS-1158862.

  1. UV irradiation of track membranes as a method for obtaining the necessary value of brittleness for good fractures of samples for sem observations

    International Nuclear Information System (INIS)

    Sartowska, B.; Nowicki, A.; Orelovitch, O.; )

    2006-01-01

    Synthesis of nano- and microstructures of materials inside the pores of specific template-track membranes can be used to obtain nano- and microwires or nano- and microtubes. It is important for these applications to know the inner geometry of the pores like sizes, shape and surface morphology. Scanning electron microscopy technique (SEM) was used predominantly for this kind of membrane characterisation. The use of other methods of sample preparation as electron, gamma rays or UV irradiation allows to make them more brittle. In present paper authors describe preliminary results of the tensile measurements of membranes after UV irradiation. Poly(ethylene terephthalate) (PET) membrane 10 μm thick with pore diameter 1.0 μm were prepared t the Joint Institute for Nuclear Research (Dubna, Russia) using the standard procedure. The samples were irradiated with UV light with energy flux 2.8 W/cm 2 during different periods of time. The tensile measurements of the initial and irradiated materials were carried in the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). In conclusion, authors claim that it is possible to find the dose of UV irradiation that ensures the fracture without elastic deformation. In the case when the time of UV irradiation increases up to 90 h, the PET membrane breaks without distortion of its channel structure

  2. Spin-polarized SEM

    International Nuclear Information System (INIS)

    Konoto, Makoto

    2007-01-01

    Development of highly effective evaluation technology of magnetic structures on a nanometric scale is a key to understanding spintronics and related phenomena. A high-resolution spin-polarized scanning electron microscope (spin SEM) developed recently is quite suitable for probing such nanostructures because of the capability of analyzing local magnetization vectors in three dimensions. Utilizing the spin SEM, a layered antiferromagnetic structure with the 1nm-alternation of bilayer-sheet magnetization has been successfully resolved. The real-space imaging with full analysis of the temperature-dependent magnetization vectors will be demonstrated. (author)

  3. SEM microcharacterization of semiconductors

    CERN Document Server

    Holt, D B

    1989-01-01

    Applications of SEM techniques of microcharacterization have proliferated to cover every type of material and virtually every branch of science and technology. This book emphasizes the fundamental physical principles. The first section deals with the foundation of microcharacterization in electron beam instruments and the second deals with the interpretation of the information obtained in the main operating modes of a scanning electron microscope.

  4. Female morphology of Philometra hyderabadensis Rasheed, 1963 (Nematoda: Philometridae), a little-known parasite of the catfish Wallago attu Bloch & Schneider in India, as revealed by SEM observations

    Czech Academy of Sciences Publication Activity Database

    Moravec, František; Chavan, S. P.

    2012-01-01

    Roč. 83, č. 2 (2012), s. 117-122 ISSN 0165-5752 R&D Projects: GA ČR GBP505/12/G112 Institutional research plan: CEZ:AV0Z60220518 Keywords : Philometra * Wallago * India Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 1.260, year: 2012

  5. Space Experiment Module (SEM)

    Science.gov (United States)

    Brodell, Charles L.

    1999-01-01

    The Space Experiment Module (SEM) Program is an education initiative sponsored by the National Aeronautics and Space Administration (NASA) Shuttle Small Payloads Project. The program provides nationwide educational access to space for Kindergarten through University level students. The SEM program focuses on the science of zero-gravity and microgravity. Within the program, NASA provides small containers or "modules" for students to fly experiments on the Space Shuttle. The experiments are created, designed, built, and implemented by students with teacher and/or mentor guidance. Student experiment modules are flown in a "carrier" which resides in the cargo bay of the Space Shuttle. The carrier supplies power to, and the means to control and collect data from each experiment.

  6. Biomonitors of urban air pollution: Magnetic studies and SEM observations of corticolous foliose and microfoliose lichens and their suitability for magnetic monitoring

    International Nuclear Information System (INIS)

    Chaparro, Marcos A.E.; Lavornia, Juan M.; Chaparro, Mauro A.E.; Sinito, Ana M.

    2013-01-01

    This study explored the suitability of available lichen species as air pollution biomonitors and assessed their potential for magnetic monitoring in cities. Several lichens on tree bark were collected in urban and industrial sites from Tandil city, as well as control sites. The results showed that magnetite-like minerals were the main magnetic carriers in all sites and samples. However, the concentration varied between clean and polluted sites. In addition, magnetic-grain size-distribution showed clear differences between sites. Observations by scanning electron microscopy showed different particles in a variety of shapes and grain sizes; moreover, the presence of iron oxides and several toxic elements was detected by energy dispersive spectroscopy analysis. Although eleven lichen species were identified that appeared suitable for use as air-pollution monitors, three of them, Parmotrema pilosum, Punctelia hipoleucites and Dirinaria picta, occurred more frequently in the area, thus constituting appropriate species for future monitoring in the study area. - Highlights: ► Magnetite-like minerals are the main carriers in lichen samples. ► Magnetic concentration and grain sizes vary between polluted and control sites. ► Different pollution loads were classified from pcoorda and K-means clustering analysis. ► Parmotrema pilosum, Punctelia hipoleucites and Dirinaria picta appear to be suitable air pollution monitors. - Lichen species are airborne pollutant collectors that are well-distributed in some urban areas and allow effective magnetic monitoring at low cost in cities.

  7. SEM and TEM Observation of the Surfaces of the Fine-Grained Particles Retrieved from the Muses-C Regio on the Asteroid 25413 Itokawa

    Science.gov (United States)

    Noguchi, T.; Nakamura, T.; Zolensky, Michael E.; Tanaka, M.; Hashimoto, T.; Konno, M.; Nakato, A.; Ogami, T.; Fujimura, A.; Abe, M.; hide

    2011-01-01

    Surface materials on airless solar system bodies exposed to interplanetary space are gradually changed their visible to near-infrared reflectance spectra by the process called "space weathering", which makes the spectra darker and redder. Hapke et al. proposed a model of space weathering: vapor deposition of nanophase reduced iron (npFe(sup 0)) on the surfaces of the grains within the very surface of lunar regolith. This model has been proved by detailed observation of the surfaces of the lunar soil grains by transmission electron microscope (TEM). They demonstrated that npFe(sup 0) was formed by a combination of vapor deposition and irradiation effects. In other words, both micrometeorite impacts and irradiation by solar wind and galactic cosmic ray play roles on the space weathering on the Moon. Because there is a continuum of reflectance spectra from those of Q-type asteroids (almost the same as those of ordinary chondrites) to those of S-type asteroids, it is strongly suggested that reflectance spectra of asteroids composed of ordinary chondrite-like materials were modified over time to those of S-type asteroids due to space weathering. It is predicted that a small amount of npFe(sup 0) on the surface of grains in the asteroidal regolith composed of ordinary chondrite-like materials is the main agent of asteroidal space weathering.

  8. Correlative SEM SERS for quantitative analysis of dimer nanoparticles.

    Science.gov (United States)

    Timmermans, F J; Lenferink, A T M; van Wolferen, H A G M; Otto, C

    2016-11-14

    A Raman microscope integrated with a scanning electron microscope was used to investigate plasmonic structures by correlative SEM-SERS analysis. The integrated Raman-SEM microscope combines high-resolution electron microscopy information with SERS signal enhancement from selected nanostructures with adsorbed Raman reporter molecules. Correlative analysis is performed for dimers of two gold nanospheres. Dimers were selected on the basis of SEM images from multi aggregate samples. The effect of the orientation of the dimer with respect to the polarization state of the laser light and the effect of the particle gap size on the Raman signal intensity is observed. Additionally, calculations are performed to simulate the electric near field enhancement. These simulations are based on the morphologies observed by electron microscopy. In this way the experiments are compared with the enhancement factor calculated with near field simulations and are subsequently used to quantify the SERS enhancement factor. Large differences between experimentally observed and calculated enhancement factors are regularly detected, a phenomenon caused by nanoscale differences between the real and 'simplified' simulated structures. Quantitative SERS experiments reveal the structure induced enhancement factor, ranging from ∼200 to ∼20 000, averaged over the full nanostructure surface. The results demonstrate correlative Raman-SEM microscopy for the quantitative analysis of plasmonic particles and structures, thus enabling a new analytical method in the field of SERS and plasmonics.

  9. O Cinema sem Imagens

    Directory of Open Access Journals (Sweden)

    Paulo Andrade

    2001-12-01

    Full Text Available A obra cinematográfica de Marguerite Duras, praticamente desconhecida pelo grande público, estabeleça intricadas relações com sua obra literária, ao promover a indiscernibilidade entre os dois campo, sem, contudo, instituir qualquer tipo de subordinação de um ao outro. O processo de criação do filme Lê camion, de 1977, aponta para outras possibilidades de se pensar o cinema e a literatura.

  10. Brain-to-brain hyperclassification reveals action-specific motor mapping of observed actions in humans.

    Science.gov (United States)

    Smirnov, Dmitry; Lachat, Fanny; Peltola, Tomi; Lahnakoski, Juha M; Koistinen, Olli-Pekka; Glerean, Enrico; Vehtari, Aki; Hari, Riitta; Sams, Mikko; Nummenmaa, Lauri

    2017-01-01

    Seeing an action may activate the corresponding action motor code in the observer. It remains unresolved whether seeing and performing an action activates similar action-specific motor codes in the observer and the actor. We used novel hyperclassification approach to reveal shared brain activation signatures of action execution and observation in interacting human subjects. In the first experiment, two "actors" performed four types of hand actions while their haemodynamic brain activations were measured with 3-T functional magnetic resonance imaging (fMRI). The actions were videotaped and shown to 15 "observers" during a second fMRI experiment. Eleven observers saw the videos of one actor, and the remaining four observers saw the videos of the other actor. In a control fMRI experiment, one of the actors performed actions with closed eyes, and five new observers viewed these actions. Bayesian canonical correlation analysis was applied to functionally realign observers' and actors' fMRI data. Hyperclassification of the seen actions was performed with Bayesian logistic regression trained on actors' data and tested with observers' data. Without the functional realignment, between-subjects accuracy was at chance level. With the realignment, the accuracy increased on average by 15 percentage points, exceeding both the chance level and the accuracy without functional realignment. The highest accuracies were observed in occipital, parietal and premotor cortices. Hyperclassification exceeded chance level also when the actor did not see her own actions. We conclude that the functional brain activation signatures underlying action execution and observation are partly shared, yet these activation signatures may be anatomically misaligned across individuals.

  11. The luminal surface of thyroid cysts in SEM

    DEFF Research Database (Denmark)

    Zelander, T; Kirkeby, S

    1978-01-01

    Four of the five kinds of cells constituting the walls of thyroid cysts can be identified in the SEM. These are cuboidal cells, mucous cells, cells with large granules and ciliated cells. A correlation between SEM and TEM observations is attempted.......Four of the five kinds of cells constituting the walls of thyroid cysts can be identified in the SEM. These are cuboidal cells, mucous cells, cells with large granules and ciliated cells. A correlation between SEM and TEM observations is attempted....

  12. SEM analysis for irradiated materials

    International Nuclear Information System (INIS)

    Liu Xiaosong; Yao Liang

    2008-06-01

    A radiation-proof Scanning Electron Microscope (SEM) system is introduced. It has been widely used in various areas. For analyzing radioactive samples, normal SEM system needs lots of alterations. Based on KYKY-2800B SEM, the sample room, belt line, operating table and aerator were updated. New radiation-proof SEM system has used to analytic surface contaminated samples and RPV materials samples. An elementary means of SEM analysis for radioactive samples was studied, and this examination supported some available references for further irradiated fuel researches. (authors)

  13. SEM Analysis of Surface Impact on Biofilm Antibiotic Treatment.

    Science.gov (United States)

    Gomes, Luciana Calheiros; Mergulhão, Filipe José

    2017-01-01

    The aim of this work was to use scanning electron microscopy (SEM) to investigate the effect of ampicillin treatment on Escherichia coli biofilms formed on two surface materials with different properties, silicone (SIL) and glass (GLA). Epifluorescence microscopy (EM) was initially used to assess biofilm formation and killing efficiency on both surfaces. This technique showed that higher bacterial colonization was obtained in the hydrophobic SIL than in the hydrophilic GLA. It has also shown that higher biofilm inactivation was attained for GLA after the antibiotic treatment (7-log reduction versus 1-log reduction for SIL). Due to its high resolution and magnification, SEM enabled a more detailed analysis of the antibiotic effect on biofilm cells, complementing the killing efficiency information obtained by EM. SEM micrographs revealed that ampicillin-treated cells have an elongated form when compared to untreated cells. Additionally, it has shown that different materials induced different levels of elongation on cells exposed to antibiotic. Biofilms formed on GLA showed a 37% higher elongation than those formed on SIL. Importantly, cell elongation was related to viability since ampicillin had a higher bactericidal effect on GLA-formed biofilms. These findings raise the possibility of using SEM for understanding the efficacy of antimicrobial treatments by observation of biofilm morphology.

  14. Spatial and Temporal Characteristics of Insulator Contaminations Revealed by Daily Observations of Equivalent Salt Deposit Density

    Directory of Open Access Journals (Sweden)

    Ling Ruan

    2015-01-01

    Full Text Available The accurate estimation of deposits adhering on insulators is of great significance to prevent pollution flashovers which cause huge costs worldwide. Researchers have developed sensors using different technologies to monitor insulator contamination on a fine time scale. However, there is lack of analysis of these data to reveal spatial and temporal characteristics of insulator contamination, and as a result the scheduling of periodical maintenance of power facilities is highly dependent on personal experience. Owing to the deployment of novel sensors, daily Equivalent Salt Deposit Density (ESDD observations of over two years were collected and analyzed for the first time. Results from 16 sites distributed in four regions of Hubei demonstrated that spatial heterogeneity can be seen at both the fine and coarse geographical scales, suggesting that current polluted area maps are necessary but are not sufficient conditions to guide the maintenance of power facilities. Both the local emission and the regional air pollution condition exert evident influences on deposit accumulation. A relationship between ESDD and PM10 was revealed by using regression analysis, proving that air pollution exerts influence on pollution accumulations on insulators. Moreover, the seasonality of ESDD was discovered for the first time by means of time series analysis, which could help engineers select appropriate times to clean the contamination. Besides, the trend component shows that the ESDD increases in a negative exponential fashion with the accumulation date (ESDD = a − b × exp(−time at a long time scale in real environments.

  15. Landscape effects on demersal fish revealed by field observations and predictive seabed modelling.

    Science.gov (United States)

    Elliott, Sophie A M; Sabatino, Alessandro D; Heath, Michael R; Turrell, William R; Bailey, David M

    2017-01-01

    Nature conservation and fisheries management often focus on particular seabed features that are considered vulnerable or important to commercial species. As a result, individual seabed types are protected in isolation, without any understanding of what effect the mixture of seabed types within the landscape has on ecosystem functions. Here we undertook predictive seabed modelling within a coastal marine protected area using observations from underwater stereo-video camera deployments and environmental information (depth, wave fetch, maximum tidal speeds, distance from coast and underlying geology). The effect of the predicted substratum type, extent and heterogeneity or the diversity of substrata, within a radius of 1500 m around each camera deployment of juvenile gadoid relative abundance was analysed. The predicted substratum model performed well with wave fetch and depth being the most influential predictor variables. Gadus morhua (Atlantic cod) were associated with relatively more rugose substrata (Algal-gravel-pebble and seagrass) and heterogeneous landscapes, than Melanogrammus aeglefinus (haddock) or Merlangius merlangus (whiting) (sand and mud). An increase in M. merlangus relative abundance was observed with increasing substratum extent. These results reveal that landscape effects should be considered when protecting the seabed for fish and not just individual seabed types. The landscape approach used in this study therefore has important implications for marine protected area, fisheries management and monitoring advice concerning demersal fish populations.

  16. A second life for old data: Global patterns in pollution ecology revealed from published observational studies

    Energy Technology Data Exchange (ETDEWEB)

    Kozlov, Mikhail V., E-mail: mikoz@utu.fi [Section of Ecology, University of Turku, 20014 Turku (Finland); Zvereva, Elena L. [Section of Ecology, University of Turku, 20014 Turku (Finland)

    2011-05-15

    A synthesis of research on the responses of terrestrial biota (1095 effect sizes) to industrial pollution (206 point emission sources) was conducted to reveal regional and global patterns from small-scale observational studies. A meta-analysis, in combination with other statistical methods, showed that the effects of pollution depend on characteristics of the specific polluter (type, amount of emission, duration of impact on biota), the affected organism (trophic group, life history), the level at which the response was measured (organism, population, community), and the environment (biome, climate). In spite of high heterogeneity in responses, we have detected several general patterns. We suggest that the development of evolutionary adaptations to pollution is a common phenomenon and that the harmful effects of pollution on terrestrial ecosystems are likely to increase as the climate warms. We argue that community- and ecosystem-level responses to pollution should be explored directly, rather than deduced from organism-level studies. - Research synthesis demonstrated that the harmful effects of pollution on terrestrial ecosystems are likely to increase as the climate warms.

  17. A second life for old data: Global patterns in pollution ecology revealed from published observational studies

    International Nuclear Information System (INIS)

    Kozlov, Mikhail V.; Zvereva, Elena L.

    2011-01-01

    A synthesis of research on the responses of terrestrial biota (1095 effect sizes) to industrial pollution (206 point emission sources) was conducted to reveal regional and global patterns from small-scale observational studies. A meta-analysis, in combination with other statistical methods, showed that the effects of pollution depend on characteristics of the specific polluter (type, amount of emission, duration of impact on biota), the affected organism (trophic group, life history), the level at which the response was measured (organism, population, community), and the environment (biome, climate). In spite of high heterogeneity in responses, we have detected several general patterns. We suggest that the development of evolutionary adaptations to pollution is a common phenomenon and that the harmful effects of pollution on terrestrial ecosystems are likely to increase as the climate warms. We argue that community- and ecosystem-level responses to pollution should be explored directly, rather than deduced from organism-level studies. - Research synthesis demonstrated that the harmful effects of pollution on terrestrial ecosystems are likely to increase as the climate warms.

  18. Characterization of some biological specimens using TEM and SEM

    Science.gov (United States)

    Ghosh, Nabarun; Smith, Don W.

    2009-05-01

    The advent of novel techniques using the Transmission and Scanning Electron Microscopes improved observation on various biological specimens to characterize them. We studied some biological specimens using Transmission and Scanning Electron Microscopes. We followed negative staining technique with Phosphotungstic acid using bacterial culture of Bacillus subtilis. Negative staining is very convenient technique to view the structural morphology of different samples including bacteria, phage viruses and filaments in a cell. We could observe the bacterial cell wall and flagellum very well when trapped the negative stained biofilm from bacterial culture on a TEM grid. We cut ultra thin sections from the fixed root tips of Pisum sativum (Garden pea). Root tips were pre fixed with osmium tetroxide and post fixed with uranium acetate and placed in the BEEM capsule for block making. The ultrathin sections on the grid under TEM showed the granular chromatin in the nucleus. The protein bodies and large vacuoles with the storage materials were conspicuous. We followed fixation, critical point drying and sputter coating with gold to view the tissues with SEM after placing on stubs. SEM view of the leaf surface of a dangerous weed Tragia hispida showed the surface trichomes. These trichomes when break on touching releases poisonous content causing skin irritation. The cultured tissue from in vitro culture of Albizia lebbeck, a tree revealed the regenerative structures including leaf buds and stomata on the tissue surface. SEM and TEM allow investigating the minute details characteristic morphological features that can be used for classroom teaching.

  19. Observable phenomena that reveal medical students' clinical reasoning ability during expert assessment of their history taking: a qualitative study

    NARCIS (Netherlands)

    Haring, C.M.; Cools, B.M.; Gurp, P.J.M. van; Meer, J.W.M. van der; Postma, C.T.

    2017-01-01

    BACKGROUND: During their clerkships, medical students are meant to expand their clinical reasoning skills during their patient encounters. Observation of these encounters could reveal important information on the students' clinical reasoning abilities, especially during history taking. METHODS: A

  20. Viewing Integrated-Circuit Interconnections By SEM

    Science.gov (United States)

    Lawton, Russel A.; Gauldin, Robert E.; Ruiz, Ronald P.

    1990-01-01

    Back-scattering of energetic electrons reveals hidden metal layers. Experiment shows that with suitable operating adjustments, scanning electron microscopy (SEM) used to look for defects in aluminum interconnections in integrated circuits. Enables monitoring, in situ, of changes in defects caused by changes in temperature. Gives truer picture of defects, as etching can change stress field of metal-and-passivation pattern, causing changes in defects.

  1. O FENÔMENO DESCORTINADOR DO DIREITO E DA GEOGRAFIA NOS MOVIMENTOS SOCIAIS: O ACESSO DE CRIANÇAS E ADOLESCENTES DO MOVIMENTO SEM TERRA À EDUCAÇÃO / THE REVEALING PHENOMENON OF LAW AND GEOGRAPHY IN SOCIAL MOVEMENTS

    Directory of Open Access Journals (Sweden)

    Jefferson Antonione Rodrigues

    2015-08-01

    Full Text Available Resumo: Da busca pela extirpação do senso comum teórico que envolve a relação entre o Direito e a Geografia se fundamenta o presente artigo que, além disso, teve como intuito o destaque à concessão do direito de educação a crianças e adolescentes do Movimento Sem Terra sob uma concepção fenomenológica de caráter libertário e humanizante, frente à afirmação dos direitos tidos como fundamentais por nosso ordenamento jurídico brasileiro. O Direito não somente existe no tempo, mas ocupa um lugar no espaço geográfico, por isso, para compreendê-lo, além da história, faz-se necessário estudar sua geografia, traçar o seu mapa, demarcar suas fronteiras que envolvem a cultura e os interesses sociais e morais fundadores de movimentos sociais reivindicadores de direitos, concessões de justiça e inclusão no processo pedagógico. Ressaltamos também que, hodiernamente, a Geografia tornou-se uma arma sofisticada de controle do espaço jurídico que se relaciona aos movimentos ditos como sociais, teorizando-se filosoficamente mediante três posicionamentos: natureza, valores e cultura. Tais posicionamentos entrelaçados formam a aura que envolve a fundamentação existencial e teórica do Direito, disso o destaque primordial à interdependência de ambos, Direito e Geografia, para o fortalecimento da coexistência fecunda e harmoniosa de integração dos povos com a aldeia global garantidora dos direitos sociais a todas as nações, principalmente garantidora do direito à educação. Palavras-chave: Direito. Geografia. Movimentos sociais. Direitos sociais. Educação.

  2. Sustained Classroom Observation: What Does It Reveal about Changing Teaching Practices?

    Science.gov (United States)

    Lawson, Tony

    2011-01-01

    In the context of the tension between classroom observation as a form of empowerment and as an instrument of control, the partnership between three 16-19 colleges and a university School of Education in delivering a programme of sustained observation over eight years is explicated. Drawing on the literature about continuing professional…

  3. Secondary emission monitor (SEM) grids.

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    A great variety of Secondary Emission Monitors (SEM) are used all over the PS Complex. At other accelerators they are also called wire-grids, harps, etc. They are used to measure beam density profiles (from which beam size and emittance can be derived) in single-pass locations (not on circulating beams). Top left: two individual wire-planes. Top right: a combination of a horizontal and a vertical wire plane. Bottom left: a ribbon grid in its frame, with connecting wires. Bottom right: a SEM-grid with its insertion/retraction mechanism.

  4. Commensurate comparisons of models with energy budget observations reveal consistent climate sensitivities

    Science.gov (United States)

    Armour, K.

    2017-12-01

    Global energy budget observations have been widely used to constrain the effective, or instantaneous climate sensitivity (ICS), producing median estimates around 2°C (Otto et al. 2013; Lewis & Curry 2015). A key question is whether the comprehensive climate models used to project future warming are consistent with these energy budget estimates of ICS. Yet, performing such comparisons has proven challenging. Within models, values of ICS robustly vary over time, as surface temperature patterns evolve with transient warming, and are generally smaller than the values of equilibrium climate sensitivity (ECS). Naively comparing values of ECS in CMIP5 models (median of about 3.4°C) to observation-based values of ICS has led to the suggestion that models are overly sensitive. This apparent discrepancy can partially be resolved by (i) comparing observation-based values of ICS to model values of ICS relevant for historical warming (Armour 2017; Proistosescu & Huybers 2017); (ii) taking into account the "efficacies" of non-CO2 radiative forcing agents (Marvel et al. 2015); and (iii) accounting for the sparseness of historical temperature observations and differences in sea-surface temperature and near-surface air temperature over the oceans (Richardson et al. 2016). Another potential source of discrepancy is a mismatch between observed and simulated surface temperature patterns over recent decades, due to either natural variability or model deficiencies in simulating historical warming patterns. The nature of the mismatch is such that simulated patterns can lead to more positive radiative feedbacks (higher ICS) relative to those engendered by observed patterns. The magnitude of this effect has not yet been addressed. Here we outline an approach to perform fully commensurate comparisons of climate models with global energy budget observations that take all of the above effects into account. We find that when apples-to-apples comparisons are made, values of ICS in models are

  5. SPITZER OBSERVATIONS OF OGLE-2015-BLG-1212 REVEAL A NEW PATH TOWARD BREAKING STRONG MICROLENS DEGENERACIES

    DEFF Research Database (Denmark)

    Bozza, V.; Shvartzvald, Y.; Udalski, A.

    2016-01-01

    Spitzer microlensing parallax observations of OGLE-2015-BLG-1212 decisively break a degeneracy between planetary and binary solutions that is somewhat ambiguous when only ground-based data are considered. Only eight viable models survive out of an initial set of 32 local minima in the parameter s...

  6. Elevated temperature transmission Kikuchi diffraction in the SEM

    DEFF Research Database (Denmark)

    Fanta, Alice Bastos; Todeschini, Matteo; Burrows, Andrew

    2018-01-01

    heating associated with this system enables reliable TKD measurements at elevated temperatures without notable disturbance from infrared radiation. The dewetting of an Au thin film into Au nanoparticles upon heating is followed with orientation mapping in a temperature range between 20 °C and 900 °C....... The local thickness variation associated with the dewetting is observed qualitatively by observing the intensity of the transmitted beam, which decreases as the film thickness increases locally. The results of this study reveal that TKD is a well suited technique to study thin-film stability and solid state...... dewetting. Moreover, the outcome of this methodological study provides a baseline for further in-situ crystallographic studies of electron transparent samples in the SEM....

  7. SEM: A Cultural Change Agent

    Science.gov (United States)

    Barnes, Bradley; Bourke, Brian

    2015-01-01

    The authors advance the concept that institutional culture is a purposeful framework by which to view SEM's utility, particularly as a cultural change agent. Through the connection of seemingly independent functions of performance and behavior, implications emerge that deepen the understanding of the influence of culture on performance outcomes…

  8. lsnjbhakta@gmail.com A Comparative SEM-EDS Elemental

    African Journals Online (AJOL)

    Michael Horsfall

    effect on food production in terrestrial and aquatic compartment in ... Processing and SEM-EDS analysis of mud: In the laboratory, the ... and for SEM image observation was 15 kV, applying .... by weathering in the Omi acid clay deposit, Japan.

  9. On the Nature of SEM Estimates of ARMA Parameters.

    Science.gov (United States)

    Hamaker, Ellen L.; Dolan, Conor V.; Molenaar, Peter C. M.

    2002-01-01

    Reexamined the nature of structural equation modeling (SEM) estimates of autoregressive moving average (ARMA) models, replicated the simulation experiments of P. Molenaar, and examined the behavior of the log-likelihood ratio test. Simulation studies indicate that estimates of ARMA parameters observed with SEM software are identical to those…

  10. Integration of community structure data reveals observable effects below sediment guideline thresholds in a large estuary

    KAUST Repository

    Tremblay, Louis A.

    2017-04-07

    The sustainable management of estuarine and coastal ecosystems requires robust frameworks due to the presence of multiple physical and chemical stressors. In this study, we assessed whether ecological health decline, based on community structure composition changes along a pollution gradient, occurred at levels below guideline threshold values for copper, zinc and lead. Canonical analysis of principal coordinates (CAP) was used to characterise benthic communities along a metal contamination gradient. The analysis revealed changes in benthic community distribution at levels below the individual guideline values for the three metals. These results suggest that field-based measures of ecological health analysed with multivariate tools can provide additional information to single metal guideline threshold values to monitor large systems exposed to multiple stressors.

  11. Can observations inside the Solar System reveal the gravitational properties of the quantum vacuum?

    CERN Document Server

    Hajdukovic, Dragan Slavkov

    2013-01-01

    The understanding of the gravitational properties of the quantum vacuum might be the next scientific revolution.It was recently proposed that the quantum vacuum contains the virtual gravitational dipoles; we argue that this hypothesis might be tested within the Solar System. The key point is that quantum vacuum ("enriched" with the gravitational dipoles) induces a retrograde precession of the perihelion. It is obvious that this phenomenon might eventually be revealed by more accurate studies of orbits of planets and orbits of the artificial Earth satellites. However, we suggest that potentialy the best "laboratory" for the study of the gravitational properties of the quantum vacuum is the Dwarf Planet Eris and its satellite Dysnomia; the distance of nearly 100AU makes it the unique system in which the precession of the perihelion of Dysnomia (around Eris) is strongly dominated by the quantum vacuum.

  12. HII 2407: AN ECLIPSING BINARY REVEALED BY K2 OBSERVATIONS OF THE PLEIADES

    Energy Technology Data Exchange (ETDEWEB)

    David, Trevor J.; Hillenbrand, Lynne A.; Zhang, Celia; Riddle, Reed L. [Department of Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Stauffer, John; Rebull, L. M. [Spitzer Science Center, California Institute of Technology, Pasadena, CA 91125 (United States); Cody, Ann Marie [NASA Ames Research Center, Mountain View, CA 94035 (United States); Conroy, Kyle; Stassun, Keivan G. [Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37235 (United States); Pope, Benjamin; Aigrain, Suzanne; Gillen, Ed [Department of Physics, University of Oxford, Keble Road, Oxford OX1 3RH (United Kingdom); Cameron, Andrew Collier [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Barrado, David [Centro de Astrobiología, INTA-CSIC, Dpto. Astrofísica, ESAC Campus, P.O. Box 78, E-28691 Villanueva de la Cañada, Madrid (Spain); Isaacson, Howard; Marcy, Geoffrey W. [Department of Astronomy, University of California, Berkeley, CA 94720 (United States); Ziegler, Carl; Law, Nicholas M. [Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255 (United States); Baranec, Christoph, E-mail: tjd@astro.caltech.edu [Institute for Astronomy, University of Hawai‘i at Mānoa, Hilo, HI 96720-2700 (United States)

    2015-11-20

    The star HII 2407 is a member of the relatively young Pleiades star cluster and was previously discovered to be a single-lined spectroscopic binary. It is newly identified here within Kepler/K2 photometric time series data as an eclipsing binary system. Mutual fitting of the radial velocity and photometric data leads to an orbital solution and constraints on fundamental stellar parameters. While the primary has arrived on the main sequence, the secondary is still pre-main sequence and we compare our results for the M/M{sub ⊙} and R/R{sub ⊙} values with stellar evolutionary models. We also demonstrate that the system is likely to be tidally synchronized. Follow-up infrared spectroscopy is likely to reveal the lines of the secondary, allowing for dynamically measured masses and elevating the system to benchmark eclipsing binary status.

  13. Direct observation of TALE protein dynamics reveals a two-state search mechanism.

    Science.gov (United States)

    Cuculis, Luke; Abil, Zhanar; Zhao, Huimin; Schroeder, Charles M

    2015-06-01

    Transcription activator-like effector (TALE) proteins are a class of programmable DNA-binding proteins for which the fundamental mechanisms governing the search process are not fully understood. Here we use single-molecule techniques to directly observe TALE search dynamics along DNA templates. We find that TALE proteins are capable of rapid diffusion along DNA using a combination of sliding and hopping behaviour, which suggests that the TALE search process is governed in part by facilitated diffusion. We also observe that TALE proteins exhibit two distinct modes of action during the search process-a search state and a recognition state-facilitated by different subdomains in monomeric TALE proteins. Using TALE truncation mutants, we further demonstrate that the N-terminal region of TALEs is required for the initial non-specific binding and subsequent rapid search along DNA, whereas the central repeat domain is required for transitioning into the site-specific recognition state.

  14. Nature of shocks revealed by SOFIA OI observations in the Cepheus e protostellar outflow

    DEFF Research Database (Denmark)

    Gusdorf, A.; Anderl, S.; Lefloch, B.

    2017-01-01

    in the various components, and to understand the nature of the underlying shocks, thus probing the origin of the mass-loss phenomenon. Methods. We present observations of the O i 3P1 → 3P2, OH between 2Π1/2Π1/22J = 3/2 and J = 1/2 at 1837.8 GHz, and CO (16-15) lines with the GREAT receiver onboard SOFIA towards...

  15. Deep pelagic food web structure as revealed by in situ feeding observations.

    Science.gov (United States)

    Choy, C Anela; Haddock, Steven H D; Robison, Bruce H

    2017-12-06

    Food web linkages, or the feeding relationships between species inhabiting a shared ecosystem, are an ecological lens through which ecosystem structure and function can be assessed, and thus are fundamental to informing sustainable resource management. Empirical feeding datasets have traditionally been painstakingly generated from stomach content analysis, direct observations and from biochemical trophic markers (stable isotopes, fatty acids, molecular tools). Each approach carries inherent biases and limitations, as well as advantages. Here, using 27 years (1991-2016) of in situ feeding observations collected by remotely operated vehicles (ROVs), we quantitatively characterize the deep pelagic food web of central California within the California Current, complementing existing studies of diet and trophic interactions with a unique perspective. Seven hundred and forty-three independent feeding events were observed with ROVs from near-surface waters down to depths approaching 4000 m, involving an assemblage of 84 different predators and 82 different prey types, for a total of 242 unique feeding relationships. The greatest diversity of prey was consumed by narcomedusae, followed by physonect siphonophores, ctenophores and cephalopods. We highlight key interactions within the poorly understood 'jelly web', showing the importance of medusae, ctenophores and siphonophores as key predators, whose ecological significance is comparable to large fish and squid species within the central California deep pelagic food web. Gelatinous predators are often thought to comprise relatively inefficient trophic pathways within marine communities, but we build upon previous findings to document their substantial and integral roles in deep pelagic food webs. © 2017 The Authors.

  16. A SUZAKU OBSERVATION OF Mkn 590 REVEALS A VANISHING SOFT EXCESS

    Energy Technology Data Exchange (ETDEWEB)

    Rivers, Elizabeth; Markowitz, Alex; Rothschild, Richard [Center for Astrophysics and Space Sciences, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92093-0424 (United States); Duro, Refiz [Dr. Karl Remeis-Sternwarte and Erlangen Centre for Astroparticle Physics, Frederic-Alexander Universitaet Erlangen-Nuernberg, 7 Sternwartstrasse, D-96049 Bamberg (Germany)

    2012-11-01

    We have analyzed a long-look Suzaku observation of the Seyfert 1.2 Mkn 590. We aimed to measure the Compton reflection strength, Fe K complex properties, and soft excess emission as had been observed previously in this source. The Compton reflection strength was measured to be in the range 0.2-1.0 depending on the model used. A moderately strong Fe K{alpha} emission line was detected with an equivalent width of {approx}120 {+-} 25 eV and an Fe K{beta} line was identified with an equivalent width of {approx}30 {+-} 20 eV, although we could not rule out contribution from ionized Fe emission at this energy. Surprisingly, we found no evidence for soft excess emission. Comparing our results with a 2004 observation from XMM-Newton we found that either the soft excess has decreased by a factor of 20-30 in 7 years or the photon index has steepened by 0.10 (with no soft excess present) while the continuum flux in the range 2-10 keV has varied only minimally (10%). This result could support recent claims that the soft excess is independent of the X-ray continuum.

  17. A SUZAKU OBSERVATION OF Mkn 590 REVEALS A VANISHING SOFT EXCESS

    International Nuclear Information System (INIS)

    Rivers, Elizabeth; Markowitz, Alex; Rothschild, Richard; Duro, Refiz

    2012-01-01

    We have analyzed a long-look Suzaku observation of the Seyfert 1.2 Mkn 590. We aimed to measure the Compton reflection strength, Fe K complex properties, and soft excess emission as had been observed previously in this source. The Compton reflection strength was measured to be in the range 0.2-1.0 depending on the model used. A moderately strong Fe Kα emission line was detected with an equivalent width of ∼120 ± 25 eV and an Fe Kβ line was identified with an equivalent width of ∼30 ± 20 eV, although we could not rule out contribution from ionized Fe emission at this energy. Surprisingly, we found no evidence for soft excess emission. Comparing our results with a 2004 observation from XMM-Newton we found that either the soft excess has decreased by a factor of 20-30 in 7 years or the photon index has steepened by 0.10 (with no soft excess present) while the continuum flux in the range 2-10 keV has varied only minimally (10%). This result could support recent claims that the soft excess is independent of the X-ray continuum.

  18. DSCOVR/EPIC observations of SO2 reveal dynamics of young volcanic eruption clouds

    Science.gov (United States)

    Carn, S. A.; Krotkov, N. A.; Taylor, S.; Fisher, B. L.; Li, C.; Bhartia, P. K.; Prata, F. J.

    2017-12-01

    Volcanic emissions of sulfur dioxide (SO2) and ash have been measured by ultraviolet (UV) and infrared (IR) sensors on US and European polar-orbiting satellites since the late 1970s. Although successful, the main limitation of these observations from low Earth orbit (LEO) is poor temporal resolution (once per day at low latitudes). Furthermore, most currently operational geostationary satellites cannot detect SO2, a key tracer of volcanic plumes, limiting our ability to elucidate processes in fresh, rapidly evolving volcanic eruption clouds. In 2015, the launch of the Earth Polychromatic Imaging Camera (EPIC) aboard the Deep Space Climate Observatory (DSCOVR) provided the first opportunity to observe volcanic clouds from the L1 Lagrange point. EPIC is a 10-band spectroradiometer spanning UV to near-IR wavelengths with two UV channels sensitive to SO2, and a ground resolution of 25 km. The unique L1 vantage point provides continuous observations of the sunlit Earth disk, from sunrise to sunset, offering multiple daily observations of volcanic SO2 and ash clouds in the EPIC field of view. When coupled with complementary retrievals from polar-orbiting UV and IR sensors such as the Ozone Monitoring Instrument (OMI), the Ozone Mapping and Profiler Suite (OMPS), and the Atmospheric Infrared Sounder (AIRS), we demonstrate how the increased observation frequency afforded by DSCOVR/EPIC permits more timely volcanic eruption detection and novel analyses of the temporal evolution of volcanic clouds. Although EPIC has detected several mid- to high-latitude volcanic eruptions since launch, we focus on recent eruptions of Bogoslof volcano (Aleutian Islands, AK, USA). A series of EPIC exposures from May 28-29, 2017, uniquely captures the evolution of SO2 mass in a young Bogoslof eruption cloud, showing separation of SO2- and ice-rich regions of the cloud. We show how analyses of these sequences of EPIC SO2 data can elucidate poorly understood processes in transient eruption

  19. Radio observations reveal a smooth circumstellar environment around the extraordinary type Ib supernova 2012au

    Energy Technology Data Exchange (ETDEWEB)

    Kamble, Atish; Soderberg, Alicia M.; Margutti, Raffaella; Milisavljevic, Dan; Chakraborti, Sayan; Dittmann, Jason; Drout, Maria; Sanders, Nathan [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Chomiuk, Laura [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Medvedev, Mikhail [The Department of Physics and Astronomy, University of Kansas, Lawrence, KS 66045 (United States); Chevalier, Roger [Department of Astronomy, University of Virginia, P.O. Box 400325, Charlottesville, VA 22904-4325 (United States); Chugai, Nikolai [Institute of Astronomy, Russian Academy of Sciences, Pyatnitskaya 48, 109017 Moscow (Russian Federation); Fransson, Claes [Department of Astronomy, The Oskar Klein Centre, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden); Nakar, Ehud, E-mail: atish.vyas@gmail.com [Raymond and Beverly Sackler School of Physics and Astronomy, Tel Aviv University, Tel Aviv 69978 (Israel)

    2014-12-10

    We present extensive radio and X-ray observations of SN 2012au, an energetic, radio-luminous supernova of Type Ib that exhibits multi-wavelength properties bridging subsets of hydrogen-poor superluminous supernovae, hypernovae, and normal core-collapse supernovae. The observations closely follow models of synchrotron emission from a shock-heated circumburst medium that has a wind density profile (ρ∝r {sup –2}). We infer a sub-relativistic velocity for the shock wave v ≈ 0.2 c and a radius of r ≈ 1.4 × 10{sup 16}cm at 25 days after the estimated date of explosion. For a wind velocity of 1000 km s{sup –1}, we determine the mass-loss rate of the progenitor to be M-dot =3.6×10{sup −6} M{sub ⊙} yr{sup −1}, consistent with the estimates from X-ray observations. We estimate the total internal energy of the radio-emitting material to be E ≈ 10{sup 47} erg, which is intermediate to SN 1998bw and SN 2002ap. The evolution of the radio light curve of SN 2012au is in agreement with its interaction with a smoothly distributed circumburst medium and the absence of stellar shells ejected from previous outbursts out to r ≈ 10{sup 17} cm from the supernova site. We conclude that the bright radio emission from SN 2012au was not dissimilar from other core-collapse supernovae despite its extraordinary optical properties, and that the evolution of the SN 2012au progenitor star was relatively quiet, marked with a steady mass loss, during the final years preceding explosion.

  20. WEAK TURBULENCE IN THE HD 163296 PROTOPLANETARY DISK REVEALED BY ALMA CO OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Flaherty, Kevin M.; Hughes, A. Meredith [Van Vleck Observatory, Astronomy Department, Wesleyan University, 96 Foss Hill Drive, Middletown, CT 06459 (United States); Rosenfeld, Katherine A.; Andrews, Sean M.; Wilner, David J. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Chiang, Eugene; Kerzner, Skylar [Department of Earth and Planetary Science, 307 McCone Hall, University of California, Berkeley, CA 94720 (United States); Simon, Jacob B. [Department of Space Studies, Southwest Research Institute, Boulder, CO 80302 (United States)

    2015-11-10

    Turbulence can transport angular momentum in protoplanetary disks and influence the growth and evolution of planets. With spatially and spectrally resolved molecular emission line measurements provided by (sub)millimeter interferometric observations, it is possible to directly measure non-thermal motions in the disk gas that can be attributed to this turbulence. We report a new constraint on the turbulence in the disk around HD 163296, a nearby young A star, determined from Atacama Large Millimeter/submillimeter Array Science Verification observations of four CO emission lines (the CO(3-2), CO(2-1), {sup 13}CO(2-1), and C{sup 18}O(2-1) transitions). The different optical depths for these lines permit probes of non-thermal line-widths at a range of physical conditions (temperature and density) and depths into the disk interior. We derive stringent limits on the non-thermal motions in the upper layers of the outer disk such that any contribution to the line-widths from turbulence is <3% of the local sound speed. These limits are approximately an order of magnitude lower than theoretical predictions for full-blown magnetohydrodynamic turbulence driven by the magnetorotational instability, potentially suggesting that this mechanism is less efficient in the outer (R ≳ 30 AU) disk than has been previously considered.

  1. SEM investigation of heart tissue samples

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, R; Amoroso, M [Physics Department, University of the West Indies, St. Augustine, Trinidad and Tobago, West Indies (Trinidad and Tobago)

    2010-07-01

    We used the scanning electron microscope to examine the cardiac tissue of a cow (Bos taurus), a pig (Sus scrofa), and a human (Homo sapiens). 1mm{sup 3} blocks of left ventricular tissue were prepared for SEM scanning by fixing in 96% ethanol followed by critical point drying (cryofixation), then sputter-coating with gold. The typical ridged structure of the myofibrils was observed for all the species. In addition crystal like structures were found in one of the samples of the heart tissue of the pig. These structures were investigated further using an EDVAC x-ray analysis attachment to the SEM. Elemental x-ray analysis showed highest peaks occurred for gold, followed by carbon, oxygen, magnesium and potassium. As the samples were coated with gold for conductivity, this highest peak is expected. Much lower peaks at carbon, oxygen, magnesium and potassium suggest that a cystallized salt such as a carbonate was present in the tissue before sacrifice.

  2. SEM investigation of heart tissue samples

    International Nuclear Information System (INIS)

    Saunders, R; Amoroso, M

    2010-01-01

    We used the scanning electron microscope to examine the cardiac tissue of a cow (Bos taurus), a pig (Sus scrofa), and a human (Homo sapiens). 1mm 3 blocks of left ventricular tissue were prepared for SEM scanning by fixing in 96% ethanol followed by critical point drying (cryofixation), then sputter-coating with gold. The typical ridged structure of the myofibrils was observed for all the species. In addition crystal like structures were found in one of the samples of the heart tissue of the pig. These structures were investigated further using an EDVAC x-ray analysis attachment to the SEM. Elemental x-ray analysis showed highest peaks occurred for gold, followed by carbon, oxygen, magnesium and potassium. As the samples were coated with gold for conductivity, this highest peak is expected. Much lower peaks at carbon, oxygen, magnesium and potassium suggest that a cystallized salt such as a carbonate was present in the tissue before sacrifice.

  3. Evolution of the 2015 Cotopaxi eruption revealed by combined geochemical & seismic observations

    Science.gov (United States)

    Hidalgo, Silvana; Battaglia, Jean; Arellano, Santiago; Sierra, Daniel; Bernard, Benjamin; Parra, Rene; Kelly, Peter; Dinger, Florian; Barrington, Charlotte; Samaniego, Pablo

    2018-01-01

    Through integration of multiple data streams to monitor volcanic unrest scientists are able to make more robust eruption forecast and to obtain a more holistic interpretation of volcanic systems. We examined gas emission and gas geochemistry, seismic and petrologic data recorded during the 2015 unrest of Cotopaxi (Ecuador) in order to decipher the origin and temporal evolution of this eruption. Identification of families of similar seismic events and the use of seismic amplitude ratios reveals temporal changes in volcanic processes. SO2 (300 to 24000 t/d), BrO/SO2 (5-10 x10-5), SO2/HCl (5.8 ± 4.8 and 6.6 ± 3.0) and CO2/SO2 (0.6 to 2.1) measured throughout the eruption indicate a shallow magmatic source. Bulk ash and glass chemistry indicate a homogenous andesitic (SiO2 wt%=56.94 ± 0.25) magma having undergone extensive S-exsolution and degassing during ascent. These data lead us to interpret this eruption as a magma intrusion and ascend to shallow levels. The intrusion progressively interacted with the hydrothermal system, boiled off water, and produced hydromagmatic explosions. A small volume of this intrusion continued to fragment and produced episodic ash emissions until it was sufficiently degassed and rheologically stiff. Based on the 470 kt of measured SO2 we estimate that ~ 65.3 x106 m3 of magma were required to supply the emitted gases. This volume exceeds the volume of erupted juvenile material by a factor of 50. This result emphasizes the importance of careful monitoring of Cotopaxi to identify the intrusion of a new batch of magma, which could rejuvenate the non-erupted material.

  4. An outflow in the Seyfert ESO 362-G18 revealed by Gemini-GMOS/IFU observations

    Science.gov (United States)

    Humire, Pedro K.; Nagar, Neil M.; Finlez, Carolina; Firpo, Verónica; Slater, Roy; Lena, Davide; Soto-Pinto, Pamela; Muñoz-Vergara, Dania; Riffel, Rogemar A.; Schmitt, Henrique R.; Kraemer, Steven B.; Schnorr-Müller, Allan; Fischer, Travis C.; Robinson, Andrew; Storchi-Bergmann, Thaisa; Crenshaw, Mike; Elvis, Martin S.

    2018-06-01

    We present two-dimensional stellar and gaseous kinematics of the inner 0.7 × 1.2 kpc2 of the Seyfert 1.5 galaxy ESO 362-G18, derived from optical (4092-7338 Å) spectra obtained with the GMOS integral field spectrograph on the Gemini South telescope at a spatial resolution of ≈170 pc and spectral resolution of 36 km s-1. ESO 362-G18 is a strongly perturbed galaxy of morphological type Sa or S0/a, with a minor merger approaching along the NE direction. Previous studies have shown that the [O III] emission shows a fan-shaped extension of ≈10'' to the SE. We detect the [O III] doublet, [N II] and Hα emission lines throughout our field of view. The stellar kinematics is dominated by circular motions in the galaxy plane, with a kinematic position angle of ≈137° and is centred approximately on the continuum peak. The gas kinematics is also dominated by rotation, with kinematic position angles ranging from 122° to 139°, projected velocity amplitudes of the order of 100 km s-1, and a mean velocity dispersion of 100 km s-1. A double-Gaussian fit to the [O III]λ5007 and Hα lines, which have the highest signal to noise ratios of the emission lines, reveal two kinematic components: (1) a component at lower radial velocities which we interpret as gas rotating in the galactic disk; and (2) a component with line of sight velocities 100-250 km s-1 higher than the systemic velocity, interpreted as originating in the outflowing gas within the AGN ionization cone. We estimate a mass outflow rate of 7.4 × 10-2 M⊙ yr-1 in the SE ionization cone (this rate doubles if we assume a biconical configuration), and a mass accretion rate on the supermassive black hole (SMBH) of 2.2 × 10-2 M⊙ yr-1. The total ionized gas mass within 84 pc of the nucleus is 3.3 × 105 M⊙; infall velocities of 34 km s-1 in this gas would be required to feed both the outflow and SMBH accretion. The reduced datacube (FITS file) is only available at the CDS via anonymous ftp to http

  5. Acoustic observation of living organisms reveals the upper limit of the oxygen minimum zone.

    Directory of Open Access Journals (Sweden)

    Arnaud Bertrand

    Full Text Available BACKGROUND: Oxygen minimum zones (OMZs are expanding in the World Ocean as a result of climate change and direct anthropogenic influence. OMZ expansion greatly affects biogeochemical processes and marine life, especially by constraining the vertical habitat of most marine organisms. Currently, monitoring the variability of the upper limit of the OMZs relies on time intensive sampling protocols, causing poor spatial resolution. METHODOLOGY/PRINCIPAL FINDINGS: Using routine underwater acoustic observations of the vertical distribution of marine organisms, we propose a new method that allows determination of the upper limit of the OMZ with a high precision. Applied in the eastern South-Pacific, this original sampling technique provides high-resolution information on the depth of the upper OMZ allowing documentation of mesoscale and submesoscale features (e.g., eddies and filaments that structure the upper ocean and the marine ecosystems. We also use this information to estimate the habitable volume for the world's most exploited fish, the Peruvian anchovy (Engraulis ringens. CONCLUSIONS/SIGNIFICANCE: This opportunistic method could be implemented on any vessel geared with multi-frequency echosounders to perform comprehensive high-resolution monitoring of the upper limit of the OMZ. Our approach is a novel way of studying the impact of physical processes on marine life and extracting valid information about the pelagic habitat and its spatial structure, a crucial aspect of Ecosystem-based Fisheries Management in the current context of climate change.

  6. Evolution in the lineament patterns associated to strong earthquakes revealed by satellite observations

    Science.gov (United States)

    Soto-Pinto, C. A.; Arellano-Baeza, A. A.; Ouzounov, D. P.

    2011-12-01

    We study the temporal evolution of the stress patterns in the crust by using high-resolution (10-300 m) satellite images from MODIS and ASTER satellite sensors. We are able to detect some changes in density and orientation of lineaments preceding earthquake events. A lineament is generally defined as a straight or a somewhat curved feature in the landscape visible in a satellite image as an aligned sequence of pixels of a contrasting intensity compared to the background. The system of lineaments extracted from the satellite images is not identical to the geological lineaments; nevertheless, it generally reflects the structure of the faults and fractures in the Earth's crust. Our analysis has shown that the system of lineaments is very dynamical, and the significant number of lineaments appeared approximately one month before an earthquake, while one month after the earthquake the lineament configuration returned to its initial state. These features were not observed in the test areas that are free of any seismic activity in that period (null hypothesis). We have designed a computational prototype capable to detect lineament evolution and to utilize both ASTER and MODIS satellite L1/L2. We will demonstrate the first successful test results for several Mw> 5 earthquakes in Chile, Peru, China, and California (USA).

  7. Direct observations of ice seasonality reveal changes in climate over the past 320–570 years

    Science.gov (United States)

    Sharma, Sapna; Magnuson, John J.; Batt, Ryan D.; Winslow, Luke; Korhonen, Johanna; Yasuyuki Aono,

    2016-01-01

    Lake and river ice seasonality (dates of ice freeze and breakup) responds sensitively to climatic change and variability. We analyzed climate-related changes using direct human observations of ice freeze dates (1443–2014) for Lake Suwa, Japan, and of ice breakup dates (1693–2013) for Torne River, Finland. We found a rich array of changes in ice seasonality of two inland waters from geographically distant regions: namely a shift towards later ice formation for Suwa and earlier spring melt for Torne, increasing frequencies of years with warm extremes, changing inter-annual variability, waning of dominant inter-decadal quasi-periodic dynamics, and stronger correlations of ice seasonality with atmospheric CO2 concentration and air temperature after the start of the Industrial Revolution. Although local factors, including human population growth, land use change, and water management influence Suwa and Torne, the general patterns of ice seasonality are similar for both systems, suggesting that global processes including climate change and variability are driving the long-term changes in ice seasonality.

  8. Framework for SEM contour analysis

    Science.gov (United States)

    Schneider, L.; Farys, V.; Serret, E.; Fenouillet-Beranger, C.

    2017-03-01

    SEM images provide valuable information about patterning capability. Geometrical properties such as Critical Dimension (CD) can be extracted from them and are used to calibrate OPC models, thus making OPC more robust and reliable. However, there is currently a shortage of appropriate metrology tools to inspect complex two-dimensional patterns in the same way as one would work with simple one-dimensional patterns. In this article we present a full framework for the analysis of SEM images. It has been proven to be fast, reliable and robust for every type of structure, and particularly for two-dimensional structures. To achieve this result, several innovative solutions have been developed and will be presented in the following pages. Firstly, we will present a new noise filter which is used to reduce noise on SEM images, followed by an efficient topography identifier, and finally we will describe the use of a topological skeleton as a measurement tool that can extend CD measurements on all kinds of patterns.

  9. SEM-based characterization techniques

    International Nuclear Information System (INIS)

    Russell, P.E.

    1986-01-01

    The scanning electron microscope is now a common instrument in materials characterization laboratories. The basic role of the SEM as a topographic imaging system has steadily been expanding to include a variety of SEM-based analytical techniques. These techniques cover the range of basic semiconductor materials characterization to live-time device characterization of operating LSI or VLSI devices. This paper introduces many of the more commonly used techniques, describes the modifications or additions to a conventional SEM required to utilize the techniques, and gives examples of the use of such techniques. First, the types of signals available from a sample being irradiated by an electron beam are reviewed. Then, where applicable, the type of spectroscopy or microscopy which has evolved to utilize the various signal types are described. This is followed by specific examples of the use of such techniques to solve problems related to semiconductor technology. Techniques emphasized include: x-ray fluorescence spectroscopy, electron beam induced current (EBIC), stroboscopic voltage analysis, cathodoluminescnece and electron beam IC metrology. Current and future trends of some of the these techniques, as related to the semiconductor industry are discussed

  10. Jupiter's Deep Cloud Structure Revealed Using Keck Observations of Spectrally Resolved Line Shapes

    Science.gov (United States)

    Bjoraker, G. L.; Wong, M.H.; de Pater, I.; Adamkovics, M.

    2015-01-01

    Technique: We present a method to determine the pressure at which significant cloud opacity is present between 2 and 6 bars on Jupiter. We use: a) the strength of a Fraunhofer absorption line in a zone to determine the ratio of reflected sunlight to thermal emission, and b) pressure- broadened line profiles of deuterated methane (CH3D) at 4.66 meters to determine the location of clouds. We use radiative transfer models to constrain the altitude region of both the solar and thermal components of Jupiter's 5-meter spectrum. Results: For nearly all latitudes on Jupiter the thermal component is large enough to constrain the deep cloud structure even when upper clouds are present. We find that Hot Spots, belts, and high latitudes have broader line profiles than do zones. Radiative transfer models show that Hot Spots in the North and South Equatorial Belts (NEB, SEB) typically do not have opaque clouds at pressures greater than 2 bars. The South Tropical Zone (STZ) at 32 degrees South has an opaque cloud top between 4 and 5 bars. From thermochemical models this must be a water cloud. We measured the variation of the equivalent width of CH3D with latitude for comparison with Jupiter's belt-zone structure. We also constrained the vertical profile of H2O in an SEB Hot Spot and in the STZ. The Hot Spot is very dry for a probability less than 4.5 bars and then follows the H2O profile observed by the Galileo Probe. The STZ has a saturated H2O profile above its cloud top between 4 and 5 bars.

  11. CHARACTERIZING THE YOUNGEST HERSCHEL-DETECTED PROTOSTARS. I. ENVELOPE STRUCTURE REVEALED BY CARMA DUST CONTINUUM OBSERVATIONS

    International Nuclear Information System (INIS)

    Tobin, John J.; Stutz, Amelia M.; Henning, Thomas; Ragan, Sarah E.; Megeath, S. Thomas; Fischer, William J.; Ali, Babar; Stanke, Thomas; Manoj, P.; Calvet, Nuria; Hartmann, Lee

    2015-01-01

    We present Combined Array for Research in Millimeter-wave Astronomy 2.9 mm dust continuum emission observations of a sample of 14 Herschel-detected Class 0 protostars in the Orion A and B molecular clouds, drawn from the PACS Bright Red Sources (PBRS) sample. These objects are characterized by very red 24-70 μm colors and prominent submillimeter emission, suggesting that they are very young Class 0 protostars embedded in dense envelopes. We detect all of the PBRS in 2.9 mm continuum emission and emission from four protostars and one starless core in the fields toward the PBRS; we also report one new PBRS source. The ratio of 2.9 mm luminosity to bolometric luminosity is higher by a factor of ∼5 on average, compared to other well-studied protostars in the Perseus and Ophiuchus clouds. The 2.9 mm visibility amplitudes for 6 of the 14 PBRS are very flat as a function of uv distance, with more than 50% of the source emission arising from radii <1500 AU. These flat visibility amplitudes are most consistent with spherically symmetric envelope density profiles with ρ ∝ R –2.5 . Alternatively, there could be a massive unresolved structure like a disk or a high-density inner envelope departing from a smooth power law. The large amount of mass on scales <1500 AU (implying high average central densities) leads us to suggest that that the PBRS with flat visibility amplitude profiles are the youngest PBRS and may be undergoing a brief phase of high mass infall/accretion and are possibly among the youngest Class 0 protostars. The PBRS with more rapidly declining visibility amplitudes still have large envelope masses, but could be slightly more evolved

  12. Ambient seismic noise interferometry in Hawai'i reveals long-range observability of volcanic tremor

    Science.gov (United States)

    Ballmer, Silke; Wolfe, Cecily; Okubo, Paul G.; Haney, Matt; Thurber, Clifford H.

    2013-01-01

    The use of seismic noise interferometry to retrieve Green's functions and the analysis of volcanic tremor are both useful in studying volcano dynamics. Whereas seismic noise interferometry allows long-range extraction of interpretable signals from a relatively weak noise wavefield, the characterization of volcanic tremor often requires a dense seismic array close to the source. We here show that standard processing of seismic noise interferometry yields volcanic tremor signals observable over large distances exceeding 50 km. Our study comprises 2.5 yr of data from the U.S. Geological Survey Hawaiian Volcano Observatory short period seismic network. Examining more than 700 station pairs, we find anomalous and temporally coherent signals that obscure the Green's functions. The time windows and frequency bands of these anomalous signals correspond well with the characteristics of previously studied volcanic tremor sources at Pu'u 'Ō'ō and Halema'uma'u craters. We use the derived noise cross-correlation functions to perform a grid-search for source location, confirming that these signals are surface waves originating from the known tremor sources. A grid-search with only distant stations verifies that useful tremor signals can indeed be recovered far from the source. Our results suggest that the specific data processing in seismic noise interferometry—typically used for Green's function retrieval—can aid in the study of both the wavefield and source location of volcanic tremor over large distances. In view of using the derived Green's functions to image heterogeneity and study temporal velocity changes at volcanic regions, however, our results illustrate how care should be taken when contamination by tremor may be present.

  13. High-Frequency Observations of Temperature and Dissolved Oxygen Reveal Under-Ice Convection in a Large Lake

    Science.gov (United States)

    Yang, Bernard; Young, Joelle; Brown, Laura; Wells, Mathew

    2017-12-01

    Detailed observations of thermal structure over an entire winter in a large lake reveal the presence of large (10-20 m) overturns under the ice, driven by diurnal solar heating. Convection can occur in the early winter, but the most vigorous convection occurred near the end of winter. Both periods are when our lake ice model suggest thinner ice that would have been transparent. This under-ice convection led to a deepening of the mixed layer over time, consistent with previous short-term studies. During periods of vigorous convection under the ice at the end of winter, the dissolved oxygen had become supersaturated from the surface to 23 m below the surface, suggesting abundant algal growth. Analysis of our high-frequency observations over the entire winter of 2015 using the Thorpe-scale method quantified the scale of mixing. Furthermore, it revealed that changes in oxygen concentrations are closely related to the intensity of mixing.

  14. International Conference on SEMS 2012

    CERN Document Server

    Liu, Chuang; Scientific explanation and methodology of science; SEMS 2012

    2014-01-01

    This volume contains the contributed papers of invitees to SEMS 2012 who have also given talks at the conference. The invitees are experts in philosophy of science and technology from Asia (besides China), Australia, Europe, Latin America, North America, as well as from within China. The papers in this volume represent the latest work of each researcher in his or her expertise; and as a result, they give a good representation of the cutting-edge researches in diverse areas in different parts of the world.

  15. The diversity and structure of marine protists in the coastal waters of China revealed by morphological observation and 454 pyrosequencing

    Science.gov (United States)

    Liu, Yun; Song, Shuqun; Chen, Tiantian; Li, Caiwen

    2017-04-01

    Pyrosequencing of the 18S rRNA gene has been widely adopted to study the eukaryotic diversity in various types of environments, and has an advantage over traditional morphology methods in exploring unknown microbial communities. To comprehensively assess the diversity and community composition of marine protists in the coastal waters of China, we applied both morphological observations and high-throughput sequencing of the V2 and V3 regions of 18S rDNA simultaneously to analyze samples collected from the surface layer of the Yellow and East China Seas. Dinoflagellates, diatoms and ciliates were the three dominant protistan groups as revealed by the two methods. Diatoms were the first dominant protistan group in the microscopic observations, with Skeletonema mainly distributed in the nearshore eutrophic waters and Chaetoceros in higher temperature and higher pH waters. The mixotrophic dinoflagellates, Gymnodinium and Gyrodinium, were more competitive in the oligotrophic waters. The pyrosequencing method revealed an extensive diversity of dinoflagellates. Chaetoceros was the only dominant diatom group in the pyrosequencing dataset. Gyrodinium represented the most abundant reads and dominated the offshore oligotrophic protistan community as they were in the microscopic observations. The dominance of parasitic dinoflagellates in the pyrosequencing dataset, which were overlooked in the morphological observations, indicates more attention should be paid to explore the potential role of this group. Both methods provide coherent clustering of samples. Nutrient levels, salinity and pH were the main factors influencing the distribution of protists. This study demonstrates that different primer pairs used in the pyrosequencing will indicate different protistan community structures. A suitable marker may reveal more comprehensive composition of protists and provide valuable information on environmental drivers.

  16. The Effect of Nonnormality on CB-SEM and PLS-SEM Path Estimates

    OpenAIRE

    Z. Jannoo; B. W. Yap; N. Auchoybur; M. A. Lazim

    2014-01-01

    The two common approaches to Structural Equation Modeling (SEM) are the Covariance-Based SEM (CB-SEM) and Partial Least Squares SEM (PLS-SEM). There is much debate on the performance of CB-SEM and PLS-SEM for small sample size and when distributions are nonnormal. This study evaluates the performance of CB-SEM and PLS-SEM under normality and nonnormality conditions via a simulation. Monte Carlo Simulation in R programming language was employed to generate data based on the theoretical model w...

  17. Observable phenomena that reveal medical students' clinical reasoning ability during expert assessment of their history taking: a qualitative study.

    Science.gov (United States)

    Haring, Catharina M; Cools, Bernadette M; van Gurp, Petra J M; van der Meer, Jos W M; Postma, Cornelis T

    2017-08-29

    During their clerkships, medical students are meant to expand their clinical reasoning skills during their patient encounters. Observation of these encounters could reveal important information on the students' clinical reasoning abilities, especially during history taking. A grounded theory approach was used to analyze what expert physicians apply as indicators in their assessment of medical students' diagnostic reasoning abilities during history taking. Twelve randomly selected clinical encounter recordings of students at the end of the internal medicine clerkships were observed by six expert assessors, who were prompted to formulate their assessment criteria in a think-aloud procedure. These formulations were then analyzed to identify the common denominators and leading principles. The main indicators of clinical reasoning ability were abstracted from students' observable acts during history taking in the encounter. These were: taking control, recognizing and responding to relevant information, specifying symptoms, asking specific questions that point to pathophysiological thinking, placing questions in a logical order, checking agreement with patients, summarizing and body language. In addition, patients' acts and the course, result and efficiency of the conversation were identified as indicators of clinical reasoning, whereas context, using self as a reference, and emotion/feelings were identified by the clinicians as variables in their assessment of clinical reasoning. In observing and assessing clinical reasoning during history taking by medical students, general and specific phenomena to be used as indicators for this process could be identified. These phenomena can be traced back to theories on the development and the process of clinical reasoning.

  18. Sexual Arousal and Sexually Explicit Media (SEM)

    DEFF Research Database (Denmark)

    Hald, Gert Martin; Stulhofer, Aleksandar; Lange, Theis

    2018-01-01

    -mainstream and mainstream SEM groups, and (iii) to explore the validity and predictive accuracy of the Non-Mainstream Pornography Arousal Scale (NPAS). METHODS: Online cross-sectional survey of 2,035 regular SEM users in Croatia. MAIN OUTCOMES MEASURES: Patterns of sexual arousal to 27 different SEM themes, sexual...

  19. Risk assessment of heavy metals in Vembanad Lake sediments (south-west coast of India), based on acid-volatile sulfide (AVS)-simultaneously extracted metal (SEM) approach.

    Science.gov (United States)

    Shyleshchandran, Mohanachandran Nair; Mohan, Mahesh; Ramasamy, Eswara Venkatesaperumal

    2018-03-01

    Contamination of estuarine system due to heavy metals is a severe issue in tropical countries, especially in India. For the evaluation of the risk due to heavy metals, the current study assessed spatial and temporal variation of acid-volatile sulfide (AVS), simultaneously extracted metal (SEM), and total metal concentration as toxicity indicator of aquatic sediments in Vembanad Lake System (VLS), India. Surface sediment samples collected from 12 locations from the northern portion of VLS for 4 years during different seasons. The results suggest, in post-monsoon season, 91% of the sampling locations possessed high bioavailability of metals and results in toxicity to aquatic biota. The average seasonal distribution of SEM during the period of observations was in the order post-monsoon > pre-monsoon > monsoon (1.76 ± 2.00 > 1.35 ± 0.60 > 0.80 ± 0.54 μmol/g). The concentration of individual metals on ∑SEM are in the order SEM Zn > SEM Cu> SEM Cd ≈ SEM Pb > SEM Hg. Considering annual ΣSEM/AVS ratio, 83% of the sites cross the critical value of 'One,' reveals that active sulfide phase of the sediment for fixing the metals is saturated. The molar ratio (differences between SEM and AVS) and its normalized organic carbon ratio reveals that in the post-monsoon season, about 42% of the sites are in the category of adverse effects are possible. The study suggests the toxicity and mobility of the metals largely depend on the available AVS, and the current situation may pose harm to benthic organisms.

  20. Cryo-Scanning Electron Microscopy (SEM) and Scanning Transmission Electron Microscopy (STEM)-in-SEM for Bio- and Organo-Mineral Interface Characterization in the Environment.

    Science.gov (United States)

    Wille, Guillaume; Hellal, Jennifer; Ollivier, Patrick; Richard, Annie; Burel, Agnes; Jolly, Louis; Crampon, Marc; Michel, Caroline

    2017-12-01

    Understanding biofilm interactions with surrounding substratum and pollutants/particles can benefit from the application of existing microscopy tools. Using the example of biofilm interactions with zero-valent iron nanoparticles (nZVI), this study aims to apply various approaches in biofilm preparation and labeling for fluorescent or electron microscopy and energy dispersive X-ray spectrometry (EDS) microanalysis for accurate observations. According to the targeted microscopy method, biofilms were sampled as flocs or attached biofilm, submitted to labeling using 4',6-diamidino-2-phenylindol, lectins PNA and ConA coupled to fluorescent dye or gold nanoparticles, and prepared for observation (fixation, cross-section, freezing, ultramicrotomy). Fluorescent microscopy revealed that nZVI were embedded in the biofilm structure as aggregates but the resolution was insufficient to observe individual nZVI. Cryo-scanning electron microscopy (SEM) observations showed nZVI aggregates close to bacteria, but it was not possible to confirm direct interactions between nZVI and cell membranes. Scanning transmission electron microscopy in the SEM (STEM-in-SEM) showed that nZVI aggregates could enter the biofilm to a depth of 7-11 µm. Bacteria were surrounded by a ring of extracellular polymeric substances (EPS) preventing direct nZVI/membrane interactions. STEM/EDS mapping revealed a co-localization of nZVI aggregates with lectins suggesting a potential role of EPS in nZVI embedding. Thus, the combination of divergent microscopy approaches is a good approach to better understand and characterize biofilm/metal interactions.

  1. GEOMETRY AND CHARACTERISTICS OF THE HELIOSHEATH REVEALED IN THE FIRST FIVE YEARS OF INTERSTELLAR BOUNDARY EXPLORER OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Zirnstein, E. J.; McComas, D. J.; Schwadron, N. A. [Southwest Research Institute, San Antonio, TX 78228 (United States); Funsten, H. O. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Heerikhuisen, J.; Zank, G. P., E-mail: ezirnstein@swri.edu [Department of Space Science, University of Alabama in Huntsville, Huntsville, AL 35899 (United States)

    2016-07-20

    We investigate and interpret the geometry and characteristics of the inner heliosheath (IHS) plasma and their impact on the heliotail structure as observed in energetic neutral atom (ENA) maps acquired during the first 5 yr of Interstellar Boundary Explorer ( IBEX ) observations. In particular, IBEX observations of the heliotail reveal distinct, localized emission features (lobes) that provide a rich set of information about the properties and evolution of the heliosheath plasma downstream of the termination shock (TS). We analyze the geometry of the heliotail lobes and find that the plane intersecting the port and starboard heliotail lobe centers is ∼6° from the solar equatorial plane, and the plane intersecting the north and south heliotail lobe centers is ∼90° from the solar equatorial plane, both indicating strong correlation with the fast–slow solar wind asymmetry, and thus reflecting the structure of the IHS flow around the Sun. We also analyze the key parameters and processes that form and shape the port and starboard lobes, which are distinctly different from the north and south lobes. By comparing IBEX ENA observations with results from a simplistic flow model of the heliosphere and a multicomponent description for pickup ions (PUIs) in the IHS, we find that the port and starboard lobe formation is driven by a thin IHS, large nose–tail asymmetry of the distance to the TS (and consequently, a large nose–tail asymmetry of the relative abundance of PUIs at the TS) and the energy-dependent removal of PUIs by charge exchange in the IHS.

  2. Observational study on the fine structure and dynamics of a solar jet. II. Energy release process revealed by spectral analysis

    Science.gov (United States)

    Sakaue, Takahito; Tei, Akiko; Asai, Ayumi; Ueno, Satoru; Ichimoto, Kiyoshi; Shibata, Kazunari

    2018-01-01

    We report on a solar jet phenomenon associated with the C5.4 class flare on 2014 November 11. The data of the jet was provided by the Solar Dynamics Observatory, the X-Ray Telescope (XRT) aboard Hinode, and the Interface Region Imaging Spectrograph and Domeless Solar Telescope (DST) at Hida Observatory, Kyoto University. These plentiful data enabled us to present this series of papers to discuss all the processes of the observed phenomena, including energy storage, event trigger, and energy release. In this paper, we focus on the energy release process of the observed jet, and mainly describe our spectral analysis on the Hα data of DST to investigate the internal structure of the Hα jet and its temporal evolution. This analysis reveals that in the physical quantity distributions of the Hα jet, such as line-of-sight velocity and optical thickness, there is a significant gradient in the direction crossing the jet. We interpret this internal structure as the consequence of the migration of the energy release site, based on the idea of ubiquitous reconnection. Moreover, by measuring the horizontal flow of the fine structures in the jet, we succeeded in deriving the three-dimensional velocity field and the line-of-sight acceleration field of the Hα jet. The analysis result indicates that part of the ejecta in the Hα jet experienced additional acceleration after it had been ejected from the lower atmosphere. This secondary acceleration was found to occur in the vicinity of the intersection between the trajectories of the Hα jet and the X-ray jet observed by Hinode/XRT. We propose that a fundamental cause of this phenomenon is magnetic reconnection involving the plasmoid in the observed jet.

  3. ERRATIC JET WOBBLING IN THE BL LACERTAE OBJECT OJ287 REVEALED BY SIXTEEN YEARS OF 7 mm VLBA OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Agudo, Ivan; Gomez, Jose L. [Instituto de Astrofisica de Andalucia, CSIC, Apartado 3004, 18080 Granada (Spain); Marscher, Alan P.; Jorstad, Svetlana G. [Institute for Astrophysical Research, Boston University, 725 Commonwealth Avenue, Boston, MA 02215 (United States); Perucho, Manel [Departament d' Astronomia i Astrofisica, Universitat de Valencia, Dr. Moliner 50, E-46100 Burjassot, Valencia (Spain); Piner, B. Glenn [Department of Physics and Astronomy, Whittier College, 13406 East Philadelphia Street, Whittier, CA 90608 (United States); Rioja, Maria [Observatorio Astronomico Nacional, Apdo. 112, E-28803 Alcala de Henares, Madrid (Spain); Dodson, Richard, E-mail: iagudo@iaa.es [ICRAR/University of Western Australia, 35 Stirling Highway, Crawley, WA 6009 (Australia)

    2012-03-01

    We present the results from an ultra-high-resolution 7 mm Very Long Baseline Array study of the relativistic jet in the BL Lacertae object OJ287 from 1995 to 2011 containing 136 total intensity images. Analysis of the image sequence reveals a sharp jet-position-angle swing by >100 Degree-Sign during [2004,2006], as viewed in the plane of the sky, which we interpret as the crossing of the jet from one side of the line of sight to the other during a softer- and longer-term swing of the inner jet. Modulating such long-term swing, our images also show for the first time a prominent erratic wobbling behavior of the innermost {approx}0.4 mas of the jet with fluctuations in position angle of up to {approx}40 Degree-Sign over timescales {approx}2 yr. This is accompanied by highly superluminal motions along non-radial trajectories, which reflect the remarkable non-ballistic nature of the jet plasma on these scales. The erratic nature and short timescales of the observed behavior rule out scenarios such as binary black hole systems, accretion disk precession, and interaction with the ambient medium as possible origins of the phenomenon on the scales probed by our observations, although such processes may cause longer-term modulation of the jet direction. We propose that variable asymmetric injection of the jet flow, perhaps related to turbulence in the accretion disk, coupled with hydrodynamic instabilities leads to the non-ballistic dynamics that causes the observed non-periodic changes in the direction of the inner jet.

  4. Observations and operational model simulations reveal the impact of Hurricane Matthew (2016) on the Gulf Stream and coastal sea level

    Science.gov (United States)

    Ezer, Tal; Atkinson, Larry P.; Tuleya, Robert

    2017-12-01

    In October 7-9, 2016, Hurricane Matthew moved along the southeastern coast of the U.S., causing major flooding and significant damage, even to locations farther north well away from the storm's winds. Various observations, such as tide gauge data, cable measurements of the Florida Current (FC) transport, satellite altimeter data and high-frequency radar data, were analyzed to evaluate the impact of the storm. The data show a dramatic decline in the FC flow and increased coastal sea level along the U.S. coast. Weakening of the Gulf Stream (GS) downstream from the storm's area contributed to high coastal sea levels farther north. Analyses of simulations of an operational hurricane-ocean coupled model reveal the disruption that the hurricane caused to the GS flow, including a decline in transport of ∼20 Sv (1 Sv = 106 m3 s-1). In comparison, the observed FC reached a maximum transport of ∼40 Sv before the storm on September 10 and a minimum of ∼20 Sv after the storm on October 12. The hurricane impacts both the geostrophic part of the GS and the wind-driven currents, generating inertial oscillations with velocities of up to ±1 m s-1. Analysis of the observed FC transport since 1982 indicated that the magnitude of the current weakening in October 2016 was quite rare (outside 3 standard deviations from the mean). Such a large FC weakening in the past occurred more often in October and November, but is extremely rare in June-August. Similar impacts on the FC from past tropical storms and hurricanes suggest that storms may contribute to seasonal and interannual variations in the FC. The results also demonstrated the extended range of coastal impacts that remote storms can cause through their influence on ocean currents.

  5. Long-term urban carbon dioxide observations reveal spatial and temporal dynamics related to urban characteristics and growth.

    Science.gov (United States)

    Mitchell, Logan E; Lin, John C; Bowling, David R; Pataki, Diane E; Strong, Courtenay; Schauer, Andrew J; Bares, Ryan; Bush, Susan E; Stephens, Britton B; Mendoza, Daniel; Mallia, Derek; Holland, Lacey; Gurney, Kevin R; Ehleringer, James R

    2018-03-20

    Cities are concentrated areas of CO 2 emissions and have become the foci of policies for mitigation actions. However, atmospheric measurement networks suitable for evaluating urban emissions over time are scarce. Here we present a unique long-term (decadal) record of CO 2 mole fractions from five sites across Utah's metropolitan Salt Lake Valley. We examine "excess" CO 2 above background conditions resulting from local emissions and meteorological conditions. We ascribe CO 2 trends to changes in emissions, since we did not find long-term trends in atmospheric mixing proxies. Three contrasting CO 2 trends emerged across urban types: negative trends at a residential-industrial site, positive trends at a site surrounded by rapid suburban growth, and relatively constant CO 2 over time at multiple sites in the established, residential, and commercial urban core. Analysis of population within the atmospheric footprints of the different sites reveals approximately equal increases in population influencing the observed CO 2 , implying a nonlinear relationship with CO 2 emissions: Population growth in rural areas that experienced suburban development was associated with increasing emissions while population growth in the developed urban core was associated with stable emissions. Four state-of-the-art global-scale emission inventories also have a nonlinear relationship with population density across the city; however, in contrast to our observations, they all have nearly constant emissions over time. Our results indicate that decadal scale changes in urban CO 2 emissions are detectable through monitoring networks and constitute a valuable approach to evaluate emission inventories and studies of urban carbon cycles.

  6. Long-term urban carbon dioxide observations reveal spatial and temporal dynamics related to urban characteristics and growth

    Science.gov (United States)

    Mitchell, Logan E.; Lin, John C.; Bowling, David R.; Pataki, Diane E.; Strong, Courtenay; Schauer, Andrew J.; Bares, Ryan; Bush, Susan E.; Stephens, Britton B.; Mendoza, Daniel; Mallia, Derek; Holland, Lacey; Gurney, Kevin R.; Ehleringer, James R.

    2018-03-01

    Cities are concentrated areas of CO2 emissions and have become the foci of policies for mitigation actions. However, atmospheric measurement networks suitable for evaluating urban emissions over time are scarce. Here we present a unique long-term (decadal) record of CO2 mole fractions from five sites across Utah’s metropolitan Salt Lake Valley. We examine “excess” CO2 above background conditions resulting from local emissions and meteorological conditions. We ascribe CO2 trends to changes in emissions, since we did not find long-term trends in atmospheric mixing proxies. Three contrasting CO2 trends emerged across urban types: negative trends at a residential-industrial site, positive trends at a site surrounded by rapid suburban growth, and relatively constant CO2 over time at multiple sites in the established, residential, and commercial urban core. Analysis of population within the atmospheric footprints of the different sites reveals approximately equal increases in population influencing the observed CO2, implying a nonlinear relationship with CO2 emissions: Population growth in rural areas that experienced suburban development was associated with increasing emissions while population growth in the developed urban core was associated with stable emissions. Four state-of-the-art global-scale emission inventories also have a nonlinear relationship with population density across the city; however, in contrast to our observations, they all have nearly constant emissions over time. Our results indicate that decadal scale changes in urban CO2 emissions are detectable through monitoring networks and constitute a valuable approach to evaluate emission inventories and studies of urban carbon cycles.

  7. Deep-water feeding and behavioral plasticity in Manta birostris revealed by archival tags and submersible observations.

    Science.gov (United States)

    Stewart, Joshua D; Hoyos-Padilla, Edgar Mauricio; Kumli, Katherine R; Rubin, Robert D

    2016-10-01

    Foraging drives many fundamental aspects of ecology, and an understanding of foraging behavior aids in the conservation of threatened species by identifying critical habitats and spatial patterns relevant to management. The world's largest ray, the oceanic manta (Manta birostris) is poorly studied and threatened globally by targeted fisheries and incidental capture. Very little information is available on the natural history, ecology and behavior of the species, complicating management efforts. This study provides the first data on the diving behavior of the species based on data returned from six tagged individuals, and an opportunistic observation from a submersible of a manta foraging at depth. Pop-off archival satellite tags deployed on mantas at the Revillagigedo Archipelago, Mexico recorded seasonal shifts in diving behavior, likely related to changes in the location and availability of zooplankton prey. Across seasons, mantas spent a large proportion of their time centered around the upper limit of the thermocline, where zooplankton often aggregate. Tag data reveal a gradual activity shift from surface waters to 100-150m across the tagging period, possibly indicating a change in foraging behavior from targeting surface-associated zooplankton to vertical migrators. The depth ranges accessed by mantas in this study carry variable bycatch risks from different fishing gear types. Consequently, region-specific data on diving behavior can help inform local management strategies that reduce or mitigate bycatch of this vulnerable species. Copyright © 2016 Elsevier GmbH. All rights reserved.

  8. Long-term acoustical observations of the mesopelagic fish Maurolicus muelleri reveal novel and varied vertical migration patterns

    KAUST Repository

    Staby, A

    2011-11-15

    We studied the temporal dynamics in the vertical distribution of Maurolicus muelleri scattering layers (SL) by examining continuous acoustic recordings over a 15 mo period in Masfjorden, Norway, complemented by intermittent sampling campaigns. The data revealed known patterns as normal diel vertical migration (DVM), midnight sinking between dusk and dawn, and periods without migrations, as well as novel behaviours consisting of early morning ascents, reverse diel vertical migrations, and interrupted ascents in the evening. During the first autumn of the study, adult fish modified their normal DVM behaviour by suspending their migration in the evening, yet ascending toward the surface in the later part of the night to reach upper layers during dawn. This behaviour was not observed during the second autumn of the study. By mid- to end of November (1st autumn), adult fish had suspended the nocturnal ascent entirely, and in the subsequent period until the end of January, a fraction of the population rather performed limited reverse migrations, slightly shifting their vertical distribution upwards during the first part of the day. From January to March 2008, fish interrupted their evening ascent at apparently random intervals and returned to deeper waters, instead of completing a full ascent to the surface. Our study underlines the value of long-term recordings, with the results suggesting that M. muelleri has the capability of changing its behaviour in response to ontogeny and internal state (satiation and hunger) as well as to external stimuli.

  9. Shifting nitrous oxide source/sink behaviour in a subtropical estuary revealed by automated time series observations

    Science.gov (United States)

    Reading, Michael J.; Santos, Isaac R.; Maher, Damien T.; Jeffrey, Luke C.; Tait, Douglas R.

    2017-07-01

    The oceans are a major source of the potent greenhouse gas nitrous oxide (N2O) to the atmosphere. However, little information is available on how estuaries and the coastal ocean may contribute to N2O budgets, and on the drivers of N2O in aquatic environments. This study utilised five time series stations along the freshwater to marine continuum in a sub-tropical estuary in Australia (Coffs Creek, Australia). Each time series station captured N2O, radon (222Rn, a natural submarine groundwater discharge tracer), dissolved nitrogen, and dissolved organic carbon (DOC) concentrations for a minimum of 25 h. The use of automated time series observations enabled spatial and tidal-scale variability of N2O to be captured. Groundwater was highly enriched in N2O (up to 306 nM) compared to the receiving surface water. Dissolved N2O supersaturation as high as 386% (27.4 nM) was observed in the upstream freshwater and brackish water areas which represented only a small (∼13%) proportion of the total estuary area. A large area of N2O undersaturation (as low as 53% or 3.9 nM) was observed in the mangrove-dominated lower estuary. This undersaturated area likely resulted from N2O consumption due to nitrate/nitrite (NOx) limitation in mangrove sediments subject to shallow porewater exchange. Overall, the estuary was a minor source of N2O to the atmosphere as the lower mangrove-dominated estuary sink of N2O counteracted groundwater-dominated source of N2O in the upper estuary. Average area-weighted N2O fluxes at the water-air interface approached zero (0.2-0.7 μmol m-2 d-1, depending on piston velocity model used), and were much lower than nitrogen-rich Northern Hemisphere estuaries that are considered large sources of N2O to the atmosphere. This study revealed a temporally and spatially diverse estuary, with areas of N2O production and consumption related to oxygen and total dissolved nitrogen availability, submarine groundwater discharge, and uptake within mangroves.

  10. Measuring topographies from conventional SEM acquisitions.

    Science.gov (United States)

    Shi, Qiwei; Roux, Stéphane; Latourte, Félix; Hild, François; Loisnard, Dominique; Brynaert, Nicolas

    2018-04-27

    The present study extends the stereoscopic imaging principle for estimating the surface topography to two orientations, namely, normal to the electron beam axis and inclined at 70° as suited for EBSD analyses. In spite of the large angle difference, it is shown that the topography can be accurately determined using regularized global Digital Image Correlation. The surface topography is compared to another estimate issued from a 3D FIB-SEM procedure where the sample surface is first covered by a Pt layer, and its initial topography is progressively revealed from successive FIB-milling. These two methods are successfully compared on a 6% strained steel specimen in an in situ mechanical test. This analysis is supplemented by a third approach estimating the change of topography from crystal rotations as measured from successive EBSD images. This last technique ignores plastic deformation, and thus only holds in an elastic regime. For the studied example, despite the large plastic flow, it is shown that crystal rotation already accounts for a significant part of the deformation-induced topography. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Three-dimensional ultrastructure of osteocytes assessed by focused ion beam-scanning electron microscopy (FIB-SEM).

    Science.gov (United States)

    Hasegawa, Tomoka; Yamamoto, Tomomaya; Hongo, Hiromi; Qiu, Zixuan; Abe, Miki; Kanesaki, Takuma; Tanaka, Kawori; Endo, Takashi; de Freitas, Paulo Henrique Luiz; Li, Minqi; Amizuka, Norio

    2018-04-01

    The aim of this study is to demonstrate the application of focused ion beam-scanning electron microscopy, FIB-SEM for revealing the three-dimensional features of osteocytic cytoplasmic processes in metaphyseal (immature) and diaphyseal (mature) trabeculae. Tibiae of eight-week-old male mice were fixed with aldehyde solution, and treated with block staining prior to FIB-SEM observation. While two-dimensional backscattered SEM images showed osteocytes' cytoplasmic processes in a fragmented fashion, three-dimensional reconstructions of FIB-SEM images demonstrated that osteocytes in primary metaphyseal trabeculae extended their cytoplasmic processes randomly, thus maintaining contact with neighboring osteocytes and osteoblasts. In contrast, diaphyseal osteocytes extended thin cytoplasmic processes from their cell bodies, which ran perpendicular to the bone surface. In addition, these osteocytes featured thick processes that branched into thinner, transverse cytoplasmic processes; at some point, however, these transverse processes bend at a right angle to run perpendicular to the bone surface. Osteoblasts also possessed thicker cytoplasmic processes that branched off as thinner processes, which then connected with cytoplasmic processes of neighboring osteocytes. Thus, FIB-SEM is a useful technology for visualizing the three-dimensional structures of osteocytes and their cytoplasmic processes.

  12. Redescription of Heterodera fici (Nematoda: Heteroderidae) with SEM Observations

    OpenAIRE

    Golden, A. Morgan; Maqbool, M. A.; Shahina, F.

    1988-01-01

    Heterodera fici is redescribed and illustrated with comparative details and revised measurements and diagnostic characters of the females, males, cysts, and juveniles from Maryland and Pakistan. This species is in the "schachtii group" (cysts lemon shaped, with bullae, and ambifenestrate) but the fenestrae in some cysts, presumab!y young ones, are small and widely spaced, appearing bifenestrate. It is most closely related to H. schachtii, H. glycines, and H. cajani but differs from these spec...

  13. An electron moiré method for a common SEM

    Institute of Scientific and Technical Information of China (English)

    Y.M.Xing; S.Kishimoto; Y.R.Zhao

    2006-01-01

    In the electron moiré method,a high-frequency grating is used to measure microscopic deformation,which promises significant potential applications for the method in the microscopic analysis of materials.However,a special beam scanning control device is required to produce a grating and generate a moiré fringe pattern for the scanning electron microscope (SEM).Because only a few SEMs used in the material science studies are equipped with this device,the use of the electron moiré method is limited.In this study,an electron moiré method for a common SEM without the beam control device is presented.A grating based on a multi-scanning concept is fabricated in any observing mode.A real-time moiré pattern can also be generated in the SEM or an optical filtering system.Without the beam control device being a prerequisite,the electron moiré method can be more widely used.The experimental results from three different types of SEMS show that high quality gratings with uniform lines and less pitch error can be fabricated by this method,and moiré patterns can also be correctly generated.

  14. Long-term acoustical observations of the mesopelagic fish Maurolicus muelleri reveal novel and varied vertical migration patterns

    KAUST Repository

    Staby, A; Rø stad, Anders; Kaartvedt, Stein

    2011-01-01

    . The data revealed known patterns as normal diel vertical migration (DVM), midnight sinking between dusk and dawn, and periods without migrations, as well as novel behaviours consisting of early morning ascents, reverse diel vertical migrations

  15. SEM probe of IC radiation sensitivity

    Science.gov (United States)

    Gauthier, M. K.; Stanley, A. G.

    1979-01-01

    Scanning Electron Microscope (SEM) used to irradiate single integrated circuit (IC) subcomponent to test for radiation sensitivity can localize area of IC less than .03 by .03 mm for determination of exact location of radiation sensitive section.

  16. SEM method for direct visual tracking of nanoscale morphological changes of platinum based electrocatalysts on fixed locations upon electrochemical or thermal treatments

    Energy Technology Data Exchange (ETDEWEB)

    Zorko, Milena [National Institute of Chemistry, Hajdrihova 19, Ljubljana (Slovenia); Centre of Excellence for Low-Carbon Technologies, Hajdrihova 19, Ljubljana (Slovenia); Jozinović, Barbara [Centre of Excellence for Low-Carbon Technologies, Hajdrihova 19, Ljubljana (Slovenia); Bele, Marjan [National Institute of Chemistry, Hajdrihova 19, Ljubljana (Slovenia); Centre of Excellence for Low-Carbon Technologies, Hajdrihova 19, Ljubljana (Slovenia); Hodnik, Nejc, E-mail: nejc.hodnik@ki.si [National Institute of Chemistry, Hajdrihova 19, Ljubljana (Slovenia); Gaberšček, Miran [National Institute of Chemistry, Hajdrihova 19, Ljubljana (Slovenia); Centre of Excellence for Low-Carbon Technologies, Hajdrihova 19, Ljubljana (Slovenia)

    2014-05-01

    A general method for tracking morphological surface changes on a nanometer scale with scanning electron microscopy (SEM) is introduced. We exemplify the usefulness of the method by showing consecutive SEM images of an identical location before and after the electrochemical and thermal treatments of platinum-based nanoparticles deposited on a high surface area carbon. Observations reveal an insight into platinum based catalyst degradation occurring during potential cycling treatment. The presence of chloride clearly increases the rate of degradation. At these conditions the dominant degradation mechanism seems to be the platinum dissolution with some subsequent redeposition on the top of the catalyst film. By contrast, at the temperature of 60 °C, under potentiostatic conditions some carbon corrosion and particle aggregation was observed. Temperature treatment simulating the annealing step of the synthesis reveals sintering of small platinum based composite aggregates into uniform spherical particles. The method provides a direct proof of induced surface phenomena occurring on a chosen location without the usual statistical uncertainty in usual, random SEM observations across relatively large surface areas. - Highlights: • A new SEM method for observations of identical locations. • Nanoscale morphological consecutive changes on identical locations. • Electrochemical and thermal treatments on platinum based nanoparticles. • Potential cycling induces platinum dissolution with redeposition on top of the film. • At 1.4 V vs. RHE and 60 °C carbon corrosion and particle aggregation is observed.

  17. Discopersicus n. gen., a New Member of the Family Tylenchidae Örley, 1880 with Detailed SEM Study on Two Known Species of the Genus Discotylenchus Siddiqi, 1980 (Nematoda; Tylenchidae) from Iran.

    Science.gov (United States)

    Yaghoubi, Ali; Pourjam, Ebrahim; Álvarez-Ortega, Sergio; Liébanas, Gracia; Atighi, Mohammad Reza; Pedram, Majid

    2016-09-01

    Discopersicus iranicus n. gen., n. comb., previously described from Iran as a new species under the genus Discotylenchus , is illustrated using light microscope and scanning electron microscope (SEM) observations and further studied using molecular characters. SEM studies revealed the newly proposed genus has oblique amphidial apertures on the lateral sides of the lip region. SEM images are also provided for two species of Discotylenchus , namely D. discretus and D. brevicaudatus , as the first SEM study of the genus . These results confirmed longitudinal amphidial aperture type on lateral sides of the lip region in genus Discotylenchus , as noted by Siddiqi while erecting the genus with D. discretus as the type species . Molecular phylogenetic analyses using partial small subunit (SSU) and large subunit (LSU) rDNA sequences revealed the affinity of the genus Discopersicus n. gen. with members of the subfamily Boleodorinae, as supported by morphological characters (mainly, the oblique amphidial opening).

  18. Advanced metrology by offline SEM data processing

    Science.gov (United States)

    Lakcher, Amine; Schneider, Loïc.; Le-Gratiet, Bertrand; Ducoté, Julien; Farys, Vincent; Besacier, Maxime

    2017-06-01

    Today's technology nodes contain more and more complex designs bringing increasing challenges to chip manufacturing process steps. It is necessary to have an efficient metrology to assess process variability of these complex patterns and thus extract relevant data to generate process aware design rules and to improve OPC models. Today process variability is mostly addressed through the analysis of in-line monitoring features which are often designed to support robust measurements and as a consequence are not always very representative of critical design rules. CD-SEM is the main CD metrology technique used in chip manufacturing process but it is challenged when it comes to measure metrics like tip to tip, tip to line, areas or necking in high quantity and with robustness. CD-SEM images contain a lot of information that is not always used in metrology. Suppliers have provided tools that allow engineers to extract the SEM contours of their features and to convert them into a GDS. Contours can be seen as the signature of the shape as it contains all the dimensional data. Thus the methodology is to use the CD-SEM to take high quality images then generate SEM contours and create a data base out of them. Contours are used to feed an offline metrology tool that will process them to extract different metrics. It was shown in two previous papers that it is possible to perform complex measurements on hotspots at different process steps (lithography, etch, copper CMP) by using SEM contours with an in-house offline metrology tool. In the current paper, the methodology presented previously will be expanded to improve its robustness and combined with the use of phylogeny to classify the SEM images according to their geometrical proximities.

  19. Revealing the Faraday depth structure of radio galaxy NGC 612 with broad-band radio polarimetric observations

    Science.gov (United States)

    Kaczmarek, J. F.; Purcell, C. R.; Gaensler, B. M.; Sun, X.; O'Sullivan, S. P.; McClure-Griffiths, N. M.

    2018-05-01

    We present full-polarization, broad-band observations of the radio galaxy NGC 612 (PKS B0131-637) from 1.3 to 3.1 GHz using the Australia Telescope Compact Array. The relatively large angular scale of the radio galaxy makes it a good candidate with which to investigate the polarization mechanisms responsible for the observed Faraday depth structure. By fitting complex polarization models to the polarized spectrum of each pixel, we find that a single polarization component can adequately describe the observed signal for the majority of the radio galaxy. While we cannot definitively rule out internal Faraday rotation, we argue that the bulk of the Faraday rotation is taking place in a thin skin that girts the polarized emission. Using minimum energy estimates, we find an implied total magnetic field strength of 4.2 μG.

  20. Oxford CyberSEM: remote microscopy

    International Nuclear Information System (INIS)

    Rahman, M; Kirkland, A; Cockayne, D; Meyer, R

    2008-01-01

    The Internet has enabled researchers to communicate over vast geographical distances, sharing ideas and documents. e-Science, underpinned by Grid and Web Services, has enabled electronic communications to the next level where, in addition to document sharing, researchers can increasingly control high precision scientific instruments over the network. The Oxford CyberSEM project developed a simple Java applet via which samples placed in a JEOL 5510LV Scanning Electron Microscope (SEM) can be manipulated and examined collaboratively over the Internet. Designed with schoolchildren in mind, CyberSEM does not require any additional hardware or software other than a generic Java-enabled web browser. This paper reflects on both the technical and social challenges in designing real-time systems for controlling scientific equipments in collaborative environments. Furthermore, it proposes potential deployment beyond the classroom setting.

  1. Partial Least Squares Strukturgleichungsmodellierung (PLS-SEM)

    DEFF Research Database (Denmark)

    Hair, Joseph F.; Hult, G. Tomas M.; Ringle, Christian M.

    (PLS-SEM) hat sich in der wirtschafts- und sozialwissenschaftlichen Forschung als geeignetes Verfahren zur Schätzung von Kausalmodellen behauptet. Dank der Anwenderfreundlichkeit des Verfahrens und der vorhandenen Software ist es inzwischen auch in der Praxis etabliert. Dieses Buch liefert eine...... anwendungsorientierte Einführung in die PLS-SEM. Der Fokus liegt auf den Grundlagen des Verfahrens und deren praktischer Umsetzung mit Hilfe der SmartPLS-Software. Das Konzept des Buches setzt dabei auf einfache Erläuterungen statistischer Ansätze und die anschauliche Darstellung zahlreicher Anwendungsbeispiele anhand...... einer einheitlichen Fallstudie. Viele Grafiken, Tabellen und Illustrationen erleichtern das Verständnis der PLS-SEM. Zudem werden dem Leser herunterladbare Datensätze, Aufgaben und weitere Fachartikel zur Vertiefung angeboten. Damit eignet sich das Buch hervorragend für Studierende, Forscher und...

  2. FIB-SEM tomography in biology.

    Science.gov (United States)

    Kizilyaprak, Caroline; Bittermann, Anne Greet; Daraspe, Jean; Humbel, Bruno M

    2014-01-01

    Three-dimensional information is much easier to understand than a set of two-dimensional images. Therefore a layman is thrilled by the pseudo-3D image taken in a scanning electron microscope (SEM) while, when seeing a transmission electron micrograph, his imagination is challenged. First approaches to gain insight in the third dimension were to make serial microtome sections of a region of interest (ROI) and then building a model of the object. Serial microtome sectioning is a tedious and skill-demanding work and therefore seldom done. In the last two decades with the increase of computer power, sophisticated display options, and the development of new instruments, an SEM with a built-in microtome as well as a focused ion beam scanning electron microscope (FIB-SEM), serial sectioning, and 3D analysis has become far easier and faster.Due to the relief like topology of the microtome trimmed block face of resin-embedded tissue, the ROI can be searched in the secondary electron mode, and at the selected spot, the ROI is prepared with the ion beam for 3D analysis. For FIB-SEM tomography, a thin slice is removed with the ion beam and the newly exposed face is imaged with the electron beam, usually by recording the backscattered electrons. The process, also called "slice and view," is repeated until the desired volume is imaged.As FIB-SEM allows 3D imaging of biological fine structure at high resolution of only small volumes, it is crucial to perform slice and view at carefully selected spots. Finding the region of interest is therefore a prerequisite for meaningful imaging. Thin layer plastification of biofilms offers direct access to the original sample surface and allows the selection of an ROI for site-specific FIB-SEM tomography just by its pronounced topographic features.

  3. Morphological and chemical information in fresh and vitrified ovarian tissues revealed by X-ray Microscopy and Fluorescence: observational study

    Science.gov (United States)

    Pascolo, L.; Venturin, I.; Gianoncelli, A.; Salomé, M.; Altissimo, M.; Bedolla, D. E.; Giolo, E.; Martinelli, M.; Luppi, S.; Romano, F.; Zweyer, M.; Ricci, G.

    2018-06-01

    Many clinical circumstances impose the necessity of collection and prolonged storage of gametes and/or ovarian tissue in order to preserve the reproduction potential of subjects. This is particularly appropriate in the case of young women and pre-pubertal girls undergoing chemotherapeutic treatments. The success of later assisted fertilization will depend on the suitable cooling protocols minimizing cryo-damages and preserving their biological function. The freeze-thaw processes of cryopreservation may induce, in fact, morphological and structural damages of oocytes and tissue mainly due to the formation of intracellular ice and to the toxicity of cryoprotectant. The most used cryo-protocol is the slow freezing procedure, but recently many authors have proposed vitrification as an alternative, because of its simplicity. The damage extent and the quality of follicles after cryopreservation are usually evaluated morphologically by conventional histological procedures, light and electron microscopy. Our laboratory, to further improve the evaluation and to better investigate damages, is adopting a combination of Synchrotron soft X-ray Microscopy (at TwinMic – Elettra) and XRF at different incident energies (at TwinMic – Elettra and ID21 – ESRF). X-ray techniques were performed on histological sections at micro and sub-micron resolution. Phase contrast and absorption images revealed changes in the compactness of the tissues, as well as cellular abnormalities revealed at sub-micrometric resolution. The distributions of the elements detected at 7.3 and 1.5 keV were compared and particularly Cl resulted to be indicative of follicle integrity. The results demonstrate the utility and the potential of X-ray microscopy and fluorescence in this research field.

  4. The Carnegie Hubble Program: The Distance and Structure of the SMC as Revealed by Mid-Infrared Observations of Cepheids

    Science.gov (United States)

    Scowcroft, Victoria; Freedman, Wendy L.; Madore, Barry F.; Monson, Andy; Persson, S. E.; Rich, Jeff; Seibert, Mark; Rigby, Jane R.

    2016-01-01

    Using Spitzer observations of classical Cepheids we have measured the true average distance modulus of the Small Magellanic Cloud (SMC) to be18.96 +/- 0.01 stat +/- 0.03sys mag (corresponding to 62+/- 0.3kpc), which is 0.48 +/- 0.01 mag more distant than the LMC. This is in agreement with previous results from Cepheid observations, as well as with measurements from other indicators such as RR Lyrae stars and the tip of the red giant branch. Utilizing the properties of the mid-infrared Leavitt Law we measured precise distances to individual Cepheids in the SMC, and have confirmed that the galaxy is tilted and elongated such that its eastern side is up to20 kpc closer than its western side. This is in agreement with the results from red clump stars and dynamical simulations of the Magellanic Clouds and Stream.

  5. Atmospheric CO2 Observations Reveal Strong Correlation Between Regional Net Biospheric Carbon Uptake and Solar-Induced Chlorophyll Fluorescence

    Science.gov (United States)

    Shiga, Yoichi P.; Tadić, Jovan M.; Qiu, Xuemei; Yadav, Vineet; Andrews, Arlyn E.; Berry, Joseph A.; Michalak, Anna M.

    2018-01-01

    Recent studies have shown the promise of remotely sensed solar-induced chlorophyll fluorescence (SIF) in informing terrestrial carbon exchange, but analyses have been limited to either plot level ( 1 km2) or hemispheric/global ( 108 km2) scales due to the lack of a direct measure of carbon exchange at intermediate scales. Here we use a network of atmospheric CO2 observations over North America to explore the value of SIF for informing net ecosystem exchange (NEE) at regional scales. We find that SIF explains space-time NEE patterns at regional ( 100 km2) scales better than a variety of other vegetation and climate indicators. We further show that incorporating SIF into an atmospheric inversion leads to a spatial redistribution of NEE estimates over North America, with more uptake attributed to agricultural regions and less to needleleaf forests. Our results highlight the synergy of ground-based and spaceborne carbon cycle observations.

  6. VLA Observations Of T CrB Reveal Increase in Radio Flux Density Between 2014 and 2016

    Science.gov (United States)

    Linford, J.; Weston, J.; Chomiuk, L.; Sokoloski, J.; Nelson, T.; Mukai, K.; Finzell, T.; Rupen, M.; Mioduszewski, A.

    2016-06-01

    We report new observations of the symbiotic binary and known recurrent nova T Coronae Borealis (T CrB) with the Karl G. Janksy Very Large Array (VLA). We recently began monitoring T CrB in 2016 May after reports that it was in a super-active state at other wavelengths (Munari, Dallaporta, & Cherini 2016, NewA, 47, 7; ATEL #8675; AAVSO Special Notice 415).

  7. DEEP CHANDRA OBSERVATIONS OF NGC 1404: CLUSTER PLASMA PHYSICS REVEALED BY AN INFALLING EARLY-TYPE GALAXY

    Energy Technology Data Exchange (ETDEWEB)

    Su, Yuanyuan; Kraft, Ralph P.; Nulsen, Paul; Forman, William R.; Randall, Scott W.; Jones, Christine; Machacek, Marie E. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Roediger, Elke [E.A. Milne Centre for Astrophysics, Department of Physics and Mathematics, University of Hull, Hull, HU6 7RX (United Kingdom); Churazov, Eugene, E-mail: yuanyuan.su@cfa.harvard.edu [Max Planck Institute for Astrophysics, Karl-Schwarzschild-Str. 1, D-85741, Garching (Germany)

    2017-01-01

    The intracluster medium (ICM), as a magnetized and highly ionized fluid, provides an ideal laboratory to study plasma physics under extreme conditions that cannot be achieved on Earth. NGC 1404 is a bright elliptical galaxy that is being gas stripped as it falls through the ICM of the Fornax Cluster. We use the new Chandra X-ray observations of NGC 1404 to study ICM microphysics. The interstellar medium of NGC 1404 is characterized by a sharp leading edge, 8 kpc from the Galaxy center, and a short downstream gaseous tail. Contact discontinuities are resolved on unprecedented spatial scales (0.″5 = 45 pc) due to the combination of the proximity of NGC 1404, the superb spatial resolution of Chandra , and the very deep (670 ks) exposure. At the leading edge, we observe sub-kiloparsec-scale eddies generated by Kelvin–Helmholtz instability (KHI) and put an upper limit of 5% Spitzer on the isotropic viscosity of the hot cluster plasma. We also observe mixing between the hot cluster gas and the cooler galaxy gas in the downstream stripped tail, which provides further evidence of a low viscosity plasma. The assumed ordered magnetic fields in the ICM ought to be smaller than 5 μ G to allow KHI to develop. The lack of an evident magnetic draping layer just outside the contact edge is consistent with such an upper limit.

  8. XRD and SEM study of alumina silicate porcelain insulator

    Science.gov (United States)

    Duddi, Dharmender; Singh, G. P.; Kalra, Swati; Shekhawat, M. S.; Tak, S. K.

    2018-05-01

    Higher strength electrical porcelain is a requirement of industry. This will be achieved by a specific composition of raw materials, which is consisted of clays and feldspars. Water absorption, particle size and insulating properties are of special interest now a day. China clay, Ball clay and Quartz are widely used by ceramic industries in Bikaner district of Rajasthan. Sample for present study were prepared by mixing of above clay, feldspar with MnO2, then shrinkage is observed. Bar shaped samples were prepared and heated up to a temperature of about 1185° C to observe shrinkage. For phase study of XRD and SEM are observed.

  9. Search Engine Marketing (SEM: Financial & Competitive Advantages of an Effective Hotel SEM Strategy

    Directory of Open Access Journals (Sweden)

    Leora Halpern Lanz

    2015-05-01

    Full Text Available Search Engine Marketing and Optimization (SEO, SEM are keystones of a hotels marketing strategy, in fact research shows that 90% of travelers start their vacation planning with a Google search. Learn five strategies that can enhance a hotels SEO and SEM strategies to boost bookings.

  10. Search Engine Marketing (SEM): Financial & Competitive Advantages of an Effective Hotel SEM Strategy

    OpenAIRE

    Leora Halpern Lanz

    2015-01-01

    Search Engine Marketing and Optimization (SEO, SEM) are keystones of a hotels marketing strategy, in fact research shows that 90% of travelers start their vacation planning with a Google search. Learn five strategies that can enhance a hotels SEO and SEM strategies to boost bookings.

  11. Greenhouse Gas Dynamics in a Salt-Wedge Estuary Revealed by High Resolution Cavity Ring-Down Spectroscopy Observations.

    Science.gov (United States)

    Tait, Douglas R; Maher, Damien T; Wong, WeiWen; Santos, Isaac R; Sadat-Noori, Mahmood; Holloway, Ceylena; Cook, Perran L M

    2017-12-05

    Estuaries are an important source of greenhouse gases to the atmosphere, but uncertainties remain in the flux rates and production pathways of greenhouse gases in these dynamic systems. This study performs simultaneous high resolution measurements of the three major greenhouse gases (carbon dioxide, methane, and nitrous oxide) as well as carbon stable isotope ratios of carbon dioxide and methane, above and below the pycnocline along a salt wedge estuary (Yarra River estuary, Australia). We identified distinct zones of elevated greenhouse gas concentrations. At the tip of salt wedge, average CO 2 and N 2 O concentrations were approximately five and three times higher than in the saline mouth of the estuary. In anaerobic bottom waters, the natural tracer radon ( 222 Rn) revealed that porewater exchange was the likely source of the highest methane concentrations (up to 1302 nM). Isotopic analysis of CH 4 showed a dominance of acetoclastic production in fresh surface waters and hydrogenotrophic production occurring in the saline bottom waters. The atmospheric flux of methane (in CO 2 equivalent units) was a major (35-53%) contributor of atmospheric radiative forcing from the estuary, while N 2 O contributed <2%. We hypothesize that the release of bottom water gases when stratification episodically breaks down will release large pulses of greenhouse gases to the atmosphere.

  12. A Cometary Bow Shock and Mid-Infrared Emission Variations Revealed in Spitzer Observations of HD 34078 and IC 405

    OpenAIRE

    France, Kevin; McCandliss, Stephan R.; Lupu, Roxana E.

    2006-01-01

    We present new infrared observations of the emission/reflection nebula IC 405 obtained with the Spitzer Space Telescope. Infrared images in the four IRAC bands (3.6, 4.5, 5.8, and 8.0 um) and two MIPS bands (24 and 70 um) are complemented by IRS spectroscopy (5-30 um) of two nebular filaments. The IRAC (8.0 um) and MIPS imaging shows evidence of a bow shock associated with the runaway O9.5V star, HD 34078, created by the interaction between the star and nebular material. The ratio of emission...

  13. Does Sexually Explicit Media (SEM) Affect Me?

    DEFF Research Database (Denmark)

    Hald, Gert Martin; Træen, Bente; Noor, Syed W

    2015-01-01

    and understanding of one’s sexual orientation.First-person effects refer to self-perceived and self-reported effects of SEM consumptionas experienced by the consumer. In addition, the study examined and provided athorough validation of the psychometric properties of the seven-item PornographyConsumption Effect...

  14. SEM: A user's manual for materials science

    International Nuclear Information System (INIS)

    Gabriel, B.L.

    1985-01-01

    This book provides a reference of techniques used by the metallurgical microscopist. It contains an introduction to the instrumentation and methods of scanning electron microscopy with historical as well as state-of-the-art methodologies. Topics covered include: SEM instrumentation, photography, energy dispersive spectroscopy, introduction to sample preparation, polished samples, fracture surfaces, replicas and thin films

  15. Building a SEM Analytics Reporting Portfolio

    Science.gov (United States)

    Goff, Jay W.; Williams, Brian G.; Kilgore, Wendy

    2016-01-01

    Effective strategic enrollment management (SEM) efforts require vast amounts of internal and external data to ensure that meaningful reporting and analysis systems can assist managers in decision making. A wide range of information is integral for leading effective and efficient student recruitment and retention programs. This article is designed…

  16. GPS-tracking and colony observations reveal variation in offshore habitat use and foraging ecology of breeding Sandwich Terns

    Science.gov (United States)

    Fijn, R. C.; de Jong, J.; Courtens, W.; Verstraete, H.; Stienen, E. W. M.; Poot, M. J. M.

    2017-09-01

    Breeding success of seabirds critically depends on their foraging success offshore. However, studies combining at-sea tracking and visual provisioning observations are scarce, especially for smaller species of seabirds. This study is the first in which breeding Sandwich Terns were tracked with GPS-loggers to collect detailed data on foraging habitat use in four breeding seasons. The maximum home range of individual Sandwich Terns comprised approximately 1900 km2 and the average foraging range was 27 km. Trip durations were on average 135 min with average trip lengths of 67 km. Actual foraging behaviour comprised 35% of the time budget of a foraging trip. Substantial year-to-year variation was found in habitat use and trip variables, yet with the exception of 2012, home range size remained similar between years. Food availability, chick age and environmental conditions are proposed as the main driving factors between inter- and intra-annual variations in trip variables. Our multi-method approach also provided geo-referenced information on prey presence and we conclude that future combining of colony observations and GPS-loggers deployments can potentially provide a near complete insight into the feeding ecology of breeding Sandwich Terns, including the behaviour of birds at sea.

  17. Experimental and observational evidence reveals that predators in natural environments do not regulate their prey: They are passengers, not drivers

    Science.gov (United States)

    White, T. C. R.

    2013-11-01

    Among both ecologists and the wider community there is a tacit assumption that predators regulate populations of their prey. But there is evidence from a wide taxonomic and geographic range of studies that predators that are adapted to co-evolved prey generally do not regulate their prey. This is because predators either cannot reproduce as fast as their prey and/or are inefficient hunters unable to catch enough prey to sustain maximum reproduction. The greater capacity of herbivores to breed successfully is, however, normally restricted by a lack of enough food of sufficient quality to support reproduction. But whenever this shortage is alleviated by a large pulse of food, herbivores increase their numbers to outbreak levels. Their predators are unable to contain this increase, but their numbers, too, surge in response to this increase in food. Eventually both their populations will crash once the food supply runs out, first for the herbivores and then for the predators. Then an “over-run” of predators will further depress the already declining prey population, appearing to be controlling its abundance. This latter phenomenon has led many ecologists to conclude that predators are regulating the numbers of their prey. However, it is the same process that is revealed during outbreaks that limits populations of both predator and prey in “normal” times, although this is usually not readily apparent. Nevertheless, as all the diverse cases discussed here attest, the abundance of predators and their co-evolved prey are both limited by their food: the predators are passengers, not drivers.

  18. Shallow vent architecture of Puyehue Cordón-Caulle, as revealed by direct observation of explosive activity

    Science.gov (United States)

    Schipper, C. I.; Tuffen, H.; Castro, J. M.

    2012-04-01

    On June 4, 2011, an explosive eruption of rhyodacitic magma began at the Puyehue Cordón-Caulle volcanic complex (PCCVC), southern Chile. Initial Plinian phases of the eruption produced tephra plumes reaching > 14 km high, the ash from which quickly circumnavigated the globe to cause widespread disruption to air traffic in the Southern Hemisphere. Within two weeks, the continuing explosive eruption was joined by synchronous effusion of lava. We present observations of complex vent activity made 7 months after the eruption onset, on January 4th and 10th, 2012, when explosive activity from PCCVC continued at a lower level of intensity. Fortuitous climatic conditions permitted direct, ground-based observation and video recording of transient vent dynamics within the asymmetrical tephra cone around the main eruptive vent complex and site of lava effusion, as well as real-time collection of juvenile ash as it rained out directly from the active plume. On Jan. 4, explosive activity was semi-continuous ash jetting punctuated by Vulcanian-like blasts. In the ~50m-diameter sub-circular base of the ~400 m-wide, asymmetrical tephra cone, near-continuous ash jetting was observed from two primary point sources. The northerly source was clearly visible, with time-averaged diameter of ~10 m, and the apparently larger southerly source was mostly obscured from view by the ash plume. Activity was at all times somewhat erratic, but followed a rough cyclicity on 30-45 s timescales, consisting of: (1) restriction of the point source into a focused ash jet up to ~50 m high, producing coarse ash dominated by tube pumice (with minor free pyroxene crystals); followed by (2) Vulcanian-like failure of the region around the point source, producing incandescent ballistic bombs thrown up to 100-200 m from the vent. Jetting from the two main point sources combined in the crater to produce a low gas-thrust region and sustained buoyant plume. Directed ash plumes that climbed and breached the inner

  19. Nanosecond pulsed laser ablation of Ge investigated by employing photoacoustic deflection technique and SEM analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yaseen, Nazish; Bashir, Shazia; Shabbir, Muhammad Kaif; Jalil, Sohail Abdul; Akram, Mahreen; Hayat, Asma; Mahmood, Khaliq; Haq, Faizan-ul; Ahmad, Riaz; Hussain, Tousif

    2016-06-01

    Nanosecond pulsed laser ablation phenomena of single crystal Ge (100) has been investigated by employing photoacoustic deflection as well as SEM analysis techniques. Nd: YAG laser (1064 nm, 10 ns, 1–10 Hz) at various laser fluences ranging from 0.2 to 11 J cm{sup −2} is employed as pump beam to ablate Ge targets. In order to evaluate in-situe ablation threshold fluence of Ge by photoacoustic deflection technique, Continuous Wave (CW) He–Ne laser (632 nm, power 10 mW) is employed as a probe beam. It travels parallel to the target surface at a distance of 3 mm and after passing through Ge plasma it causes deflection due to density gradient of acoustic waves. The deflected signal is detected by photodiode and is recorded by oscilloscope. The threshold fluence of Ge, the velocity of ablated species and the amplitude of the deflected signal are evaluated. The threshold fluence of Ge comes out to be 0.5 J cm{sup −2} and is comparable with the analytical value. In order to compare the estimated value of threshold with ex-situe measurements, the quantitative analysis of laser irradiated Ge is performed by using SEM analysis. For this purpose Ge is exposed to single and multiple shots of 5, 10, 50 and 100 at various laser fluences ranging from 0.2 to 11 J cm{sup −2}. The threshold fluence for single and multiple shots as well as incubation coefficients are evaluated. It is observed that the value of incubation co-efficient decreases with increasing number of pulses and is therefore responsible for lowering the threshold fluence of Ge. SEM analysis also reveals the growth of various features such as porous structures, non-uniform ripples and blisters on the laser irradiated Ge. It is observed that both the fluence as well as number of laser shots plays a significant role for the growth of these structures.

  20. Nanosecond pulsed laser ablation of Ge investigated by employing photoacoustic deflection technique and SEM analysis

    International Nuclear Information System (INIS)

    Yaseen, Nazish; Bashir, Shazia; Shabbir, Muhammad Kaif; Jalil, Sohail Abdul; Akram, Mahreen; Hayat, Asma; Mahmood, Khaliq; Haq, Faizan-ul; Ahmad, Riaz; Hussain, Tousif

    2016-01-01

    Nanosecond pulsed laser ablation phenomena of single crystal Ge (100) has been investigated by employing photoacoustic deflection as well as SEM analysis techniques. Nd: YAG laser (1064 nm, 10 ns, 1–10 Hz) at various laser fluences ranging from 0.2 to 11 J cm"−"2 is employed as pump beam to ablate Ge targets. In order to evaluate in-situe ablation threshold fluence of Ge by photoacoustic deflection technique, Continuous Wave (CW) He–Ne laser (632 nm, power 10 mW) is employed as a probe beam. It travels parallel to the target surface at a distance of 3 mm and after passing through Ge plasma it causes deflection due to density gradient of acoustic waves. The deflected signal is detected by photodiode and is recorded by oscilloscope. The threshold fluence of Ge, the velocity of ablated species and the amplitude of the deflected signal are evaluated. The threshold fluence of Ge comes out to be 0.5 J cm"−"2 and is comparable with the analytical value. In order to compare the estimated value of threshold with ex-situe measurements, the quantitative analysis of laser irradiated Ge is performed by using SEM analysis. For this purpose Ge is exposed to single and multiple shots of 5, 10, 50 and 100 at various laser fluences ranging from 0.2 to 11 J cm"−"2. The threshold fluence for single and multiple shots as well as incubation coefficients are evaluated. It is observed that the value of incubation co-efficient decreases with increasing number of pulses and is therefore responsible for lowering the threshold fluence of Ge. SEM analysis also reveals the growth of various features such as porous structures, non-uniform ripples and blisters on the laser irradiated Ge. It is observed that both the fluence as well as number of laser shots plays a significant role for the growth of these structures.

  1. SEM and AFM studies of dip-coated CuO nanofilms.

    Science.gov (United States)

    Dhanasekaran, V; Mahalingam, T; Ganesan, V

    2013-01-01

    Cupric oxide (CuO) semiconducting thin films were prepared at various copper sulfate concentrations by dip coating. The copper sulfate concentration was varied to yield films of thicknesses in the range of 445-685 nm by surface profilometer. X-ray diffraction patterns revealed that the deposited films were polycrystalline in nature with monoclinic structure of (-111) plane. The surface morphology and topography of monoclinic-phase CuO thin films were examined using scanning electron microscopy (SEM) and atomic force microscopy (AFM), respectively. Surface roughness profile was plotted using WSxM software and the estimated surface roughness was about ∼19.4 nm at 30 mM molar concentration. The nanosheets shaped grains were observed by SEM and AFM studies. The stoichiometric compound formation was observed at 30 mM copper sulfate concentration prepared film by EDX. The indirect band gap energy of CuO films was increased from 1.08 to 1.20 eV with the increase of copper sulfate concentrations. Copyright © 2012 Wiley Periodicals, Inc.

  2. Structure of the Circumnuclear Region of Seyfert 2 Galaxies Revealed by RXTE Hard X-Ray Observations of NGC 4945

    Science.gov (United States)

    Madejski, G.; Zycki, P.; Done, C.; Valinia, A.; Blanco, P.; Rothschild, R.; Turek, B.

    2000-01-01

    NGC 4945 is one of the brightest Se.yfert galaxies on the sky at 100 keV, but is completely absorbed below 10 keV, implying an optical depth of the absorber to electron scattering of a few; its absorption column is probably the largest which still allows a direct view of the nucleus at hard X-ray energies. Our observations of it with the Rossi X-ray Timing Explorer (RXTE) satellite confirm the large absorption, which for a simple phenomenological fit using an absorber with Solar abundances implies a column of 4.5(sup 0.4, sub -0.4) x 10(exp 24) /sq cm. Using a a more realistic scenario (requiring Monte Carlo modeling of the scattering), we infer the optical depth to Thomson scattering of approximately 2.4. If such a scattering medium were to subtend a large solid angle from the nucleus, it should smear out any intrinsic hard X-ray variability on time scales shorter than the light travel time through it. The rapid (with a time scale of approximately a day) hard X-ray variability of NGC 4945 we observed with the RXTE implies that the bulk of the extreme absorption in this object does not originate in a parsec-size, geometrically thick molecular torus. Limits on the amount of scattered flux require that the optically thick material on parsec scales must be rather geometrically thin, subtending a half-angle < 10 deg. This is only marginally consistent with the recent determinations of the obscuring column in hard X-rays, where only a quarter of Seyfert 2s have columns which are optically thick, and presents a problem in accounting for the Cosmic X-ray Background primarily with AGN possessing the geometry as that inferred by us. The small solid angle of the obscuring material, together with the black hole mass (of approximately 1.4 x 10(exp 6) solar mass) from megamaser measurements. allows a robust determination of the source luminosity, which in turn implies that the source radiates at approximately 10% of the Eddington limit.

  3. Ground deformation source model at Kuchinoerabu-jima volcano during 2006-2014 as revealed by campaign GPS observation

    Science.gov (United States)

    Hotta, Kohei; Iguchi, Masato

    2017-12-01

    We analyzed campaign Global Positioning System observation data in Kuchinoerabu-jima during 2006-2014. Most benchmarks located around Shin-dake crater showed crater-centered radial horizontal displacements. Horizontal displacements at western rim of the Shin-dake crater were tended to be larger compared to those at eastern rim. In addition, benchmark KUC14 which locates near the cliff at Furu-dake showed westward horizontal displacement rather than crater-centered radial (southward) one. Meanwhile, small displacements were detected at the benchmarks located at the foot of Kuchinoerabu-jima. We modeled the observed displacements applying a finite element method. We set entire FE domain as 100 × 100 × 50 km3. We set top of the domain as a free surface, and sides and bottom to be fixed boundaries. Topography was introduced in the area within Kuchinoerabu-jima using digital elevation model data provided by Kagoshima prefecture and elevation information from Google earth, and elevation of the outside area was assumed to be sea level. We assumed a stratified structure based on a one-dimensional P-wave velocity structure. We applied a vertical spheroid source model and searched optimal values of horizontal location, depth, equatorial and polar radiuses, and internal pressure change of the source using the forward modeling method. A spherical source with a radius of 50 m was obtained beneath the Shin-dake crater at a depth of 400 m above sea level. The internal pressure increase of 361 MPa yields its volume increase of 31,700 m3. Taking effects of topography and heterogeneity of ground into account allowed reproduction of overall deformation in Kuchinoerabu-jima. The location of deformation source coincides with hypocenters of shallow volcano-tectonic (VT) earthquakes and the aquifer estimated from a two-dimensional resistivity model by audio-frequency magnetotellurics method. The obtained deformation source may be corresponding to the pressurized aquifer, and shallow VT

  4. SN 2010jl: Optical to hard X-ray observations reveal an explosion embedded in a ten solar mass cocoon

    International Nuclear Information System (INIS)

    Ofek, Eran O.; Gal-Yam, Avishay; Arcavi, Iair; Zoglauer, Andreas; Boggs, Steven E.; Barriére, Nicolas M.; Reynolds, Stephen P.; Fryer, Chris L.; Even, Wesley; Harrison, Fiona A.; Kulkarni, Shrinivas R.; Bellm, Eric; Grefenstette, Brian; Cenko, S. Bradley; Bloom, Joshua S.; Filippenko, Alexei V.; Christensen, Finn; Craig, William W.; Hailey, Charles J.; Laher, Russ

    2014-01-01

    Some supernovae (SNe) may be powered by the interaction of the SN ejecta with a large amount of circumstellar matter (CSM). However, quantitative estimates of the CSM mass around such SNe are missing when the CSM material is optically thick. Specifically, current estimators are sensitive to uncertainties regarding the CSM density profile and the ejecta velocity. Here we outline a method to measure the mass of the optically thick CSM around such SNe. We present new visible-light and X-ray observations of SN 2010jl (PTF 10aaxf), including the first detection of an SN in the hard X-ray band using NuSTAR. The total radiated luminosity of SN 2010jl is extreme—at least 9 × 10 50 erg. By modeling the visible-light data, we robustly show that the mass of the circumstellar material within ∼10 16 cm of the progenitor of SN 2010jl was in excess of 10 M ☉ . This mass was likely ejected tens of years prior to the SN explosion. Our modeling suggests that the shock velocity during shock breakout was ∼6000 km s –1 , decelerating to ∼2600 km s –1 about 2 yr after maximum light. Furthermore, our late-time NuSTAR and XMM spectra of the SN presumably provide the first direct measurement of SN shock velocity 2 yr after the SN maximum light—measured to be in the range of 2000-4500 km s –1 if the ions and electrons are in equilibrium, and ≳ 2000 km s –1 if they are not in equilibrium. This measurement is in agreement with the shock velocity predicted by our modeling of the visible-light data. Our observations also show that the average radial density distribution of the CSM roughly follows an r –2 law. A possible explanation for the ≳ 10 M ☉ of CSM and the wind-like profile is that they are the result of multiple pulsational pair instability events prior to the SN explosion, separated from each other by years.

  5. Repetitive transcranial magnetic stimulation reveals a role for the left inferior parietal lobule in matching observed kinematics during imitation.

    Science.gov (United States)

    Reader, Arran T; Royce, Ben P; Marsh, Jade E; Chivers, Katy-Jayne; Holmes, Nicholas P

    2018-04-01

    Apraxia (a disorder of complex movement) suggests that the left inferior parietal lobule (IPL) plays a role in kinematic or spatial aspects of imitation, which may be particularly important for meaningless (i.e. unfamiliar intransitive) actions. Mirror neuron theories indicate that the IPL is part of a frontoparietal system that can support imitation by linking observed and stored actions through visuomotor matching, and have less to say about different subregions of the left IPL, or how different types of action (i.e. meaningful or meaningless) are processed for imitation. We used repetitive transcranial magnetic stimulation (rTMS) to bridge this gap and better understand the roles of the left supramarginal gyrus (SMG) and left angular gyrus (AG) in imitation. We also examined whether these areas are differentially involved in meaningful and meaningless action imitation. We applied rTMS over the left SMG, over the left AG or during a no-rTMS baseline condition, and then asked participants to imitate a confederate's actions whilst the arm and hand movements of both individuals were motion-tracked. rTMS over both the left SMG and the left AG reduced the velocity of participants' finger movements relative to the actor during imitation of finger gestures, regardless of action meaning. Our results support recent claims in apraxia and confirm a role for the left IPL in kinematic processing during gesture imitation, regardless of action meaning. © 2018 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  6. Dynamic observations of vesiculation reveal the role of silicate crystals in bubble nucleation and growth in andesitic magmas

    Energy Technology Data Exchange (ETDEWEB)

    Pleše, P.; Higgins, M. D.; Mancini, L.; Lanzafame, G.; Brun, F.; Fife, J. L.; Casselman, J.; Baker, D. R.

    2018-01-01

    Bubble nucleation and growth control the explosivity of volcanic eruptions, and the kinetics of these processes are generally determined from examinations of natural samples and quenched experimental run products. These samples, however, only provide a view of the final state, from which the initial conditions of a time-evolving magmatic system are then inferred. The interpretations that follow are inexact due to the inability of determining the exact conditions of nucleation and the potential detachment of bubbles from their nucleation sites, an uncertainty that can obscure their nucleation location – either homogeneously within the melt or heterogeneously at the interface between crystals and melts. We present results of a series of dynamic, real-time 4D X-ray tomographic microscopy experiments where we observed the development of bubbles in crystal bearing silicate magmas. Experimentally synthesized andesitic glasses with 0.25–0.5 wt% H2O and seed silicate crystals were heated at 1 atm to induce bubble nucleation and track bubble growth and movement. In contrast to previous studies on natural and experimentally produced samples, we found that bubbles readily nucleated on plagioclase and clinopyroxene crystals, that their contact angle changes during growth and that they can grow to sizes many times that of the silicate on whose surface they originated. The rapid heterogeneous nucleation of bubbles at low degrees of supersaturation in the presence of silicate crystals demonstrates that silicates can affect when vesiculation ensues, influencing subsequent permeability development and effusive vs. explosive transition in volcanic eruptions.

  7. An extraordinary ULF wave episode during the 2003 Halloween superstorm revealed by wavelet transforms of multipoint observations

    Science.gov (United States)

    Balasis, G.; Daglis, I. A.; Georgiou, M.; Papadimitriou, C.; Zesta, E.; Mann, I.

    2013-09-01

    We investigate a rare concurrent observation of an ultra low frequency (ULF) wave event in the Earth's magnetosphere, topside ionosphere and surface employing a time-frequency analysis technique. We have examined the ULF wave activity in the Pc3 (22-100 mHz) and Pc4-5 (1-22 mHz) frequency bands within a short time interval during the Halloween 2003 magnetic storm, when the Cluster and CHAMP spacecraft were in good local time (LT) conjunction near the dayside noon-midnight meridian. A key finding of the wavelet spectral analysis of data collected from the Geotail, Cluster and CHAMP spacecraft, and the CARISMA and GIMA magnetometer networks was a remarkably clear transition of the waves' frequency into a higher regime within the Pc3 range. Our study offers insights into the energy transfer traced all the way from the solar wind through the magnetosphere and ionosphere to the ground. This work has received support from the European Community's Seventh Framework Programme under grant agreement no. 284520 for the MAARBLE (Monitoring, Analyzing and Assessing Radiation Belt Energization and Loss) collaborative research project.

  8. Dynamic observations of vesiculation reveal the role of silicate crystals in bubble nucleation and growth in andesitic magmas

    Science.gov (United States)

    Pleše, P.; Higgins, M. D.; Mancini, L.; Lanzafame, G.; Brun, F.; Fife, J. L.; Casselman, J.; Baker, D. R.

    2018-01-01

    Bubble nucleation and growth control the explosivity of volcanic eruptions, and the kinetics of these processes are generally determined from examinations of natural samples and quenched experimental run products. These samples, however, only provide a view of the final state, from which the initial conditions of a time-evolving magmatic system are then inferred. The interpretations that follow are inexact due to the inability of determining the exact conditions of nucleation and the potential detachment of bubbles from their nucleation sites, an uncertainty that can obscure their nucleation location - either homogeneously within the melt or heterogeneously at the interface between crystals and melts. We present results of a series of dynamic, real-time 4D X-ray tomographic microscopy experiments where we observed the development of bubbles in crystal bearing silicate magmas. Experimentally synthesized andesitic glasses with 0.25-0.5 wt% H2O and seed silicate crystals were heated at 1 atm to induce bubble nucleation and track bubble growth and movement. In contrast to previous studies on natural and experimentally produced samples, we found that bubbles readily nucleated on plagioclase and clinopyroxene crystals, that their contact angle changes during growth and that they can grow to sizes many times that of the silicate on whose surface they originated. The rapid heterogeneous nucleation of bubbles at low degrees of supersaturation in the presence of silicate crystals demonstrates that silicates can affect when vesiculation ensues, influencing subsequent permeability development and effusive vs. explosive transition in volcanic eruptions.

  9. Surface characteristics of isopod digestive gland epithelium studied by SEM.

    Science.gov (United States)

    Millaku, Agron; Leser, Vladka; Drobne, Damjana; Godec, Matjaz; Torkar, Matjaz; Jenko, Monika; Milani, Marziale; Tatti, Francesco

    2010-05-01

    The structure of the digestive gland epithelium of a terrestrial isopod Porcellio scaber has been investigated by conventional scanning electron microscopy (SEM), focused ion beam-scanning electron microscopy (FIB/SEM), and light microscopy in order to provide evidence on morphology of the gland epithelial surface in animals from a stock culture. We investigated the shape of cells, extrusion of lipid droplets, shape and distribution of microvilli, and the presence of bacteria on the cell surface. A total of 22 animals were investigated and we found some variability in the appearance of the gland epithelial surface. Seventeen of the animals had dome-shaped digestive gland "normal" epithelial cells, which were densely and homogeneously covered by microvilli and varying proportions of which extruded lipid droplets. On the surface of microvilli we routinely observed sparsely distributed bacteria of different shapes. Five of the 22 animals had "abnormal" epithelial cells with a significantly altered shape. In three of these animals, the cells were much smaller, partly or completely flat or sometimes pyramid-like. A thick layer of bacteria was detected on the microvillous border, and in places, the shape and size of microvilli were altered. In two animals, hypertrophic cells containing large vacuoles were observed indicating a characteristic intracellular infection. The potential of SEM in morphological investigations of epithelial surfaces is discussed.

  10. Bases de Datos Semánticas

    Directory of Open Access Journals (Sweden)

    Irving Caro Fierros

    2016-12-01

    Full Text Available En 1992, cuando Tim Berners-Lee dio a conocer la primera  versión  de  la  Web,  su  visión  a  futuro  era  incorporar metadatos  con  información  semántica  en  las  páginas  Web.  Es precisamente   a   principios   de   este   siglo   que   inicia   el   auge repentino  de  la  Web  semántica  en  el  ambiente  académico  e Internet. El modelo de datos semántico se define como un modelo conceptual que permite definir el significado de los datos a través de  sus  relaciones  con  otros.  En  este  sentido,  el  formato  de representación  de  los  datos  es  fundamental  para  proporcionar información de carácter semántico. La tecnología enfocada en las bases de datos semánticas se encuentra actualmente en un punto de  inflexión,  al  pasar  del  ámbito  académico  y  de  investigación  a ser una opción comercial completa. En este artículo se realiza un análisis  del  concepto  de  base  de  datos  semántica.  También  se presenta  un  caso  de  estudio  donde  se  ejemplifican  operaciones básicas  que  involucran  la  gestión  de  la  información  almacenada en este tipo de base de datos.

  11. VLT/SINFONI Observations of Spitzer /MIPSGAL 24 μ m Circumstellar Shells: Revealing the Natures of Their Central Sources

    Energy Technology Data Exchange (ETDEWEB)

    Silva, K. M. [Physics and Astronomy Department, University of Hawaii Hilo, 200 W Kawili Street, Hilo, HI 96720 (United States); Flagey, N. [Canada–France–Hawaii Telescope Corporation, 65-1238 Mamalahoa Highway, Kamuela, HI 96743 (United States); Noriega-Crespo, A. [Space Telescope Science Institue, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Carey, S. [Infrared Processing Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Ingallinera, A., E-mail: silvakm@hawaii.edu [INAF-Osservatorio Astrofisico di Catania, Via Santa Sofia 78, I-95123 Catania (Italy)

    2017-03-01

    We present Very Large Telescope/Spectrograph for INtegral Field Observations in the Near Infrared H - and K -band spectra of potential central stars within the inner 8″-by-8″ regions of 55 MIPSGAL “bubbles” (MBs), sub-arcminute circumstellar shells discovered in the mid-IR survey of the Galactic plane with Spitzer /MIPS. At magnitudes brighter than 15, we detect a total of 230 stars in the K band and 179 stars in the H band. We spectrally identify 145 stars in all but three MBs, with average magnitudes of 13.8 and 12.7 respectively, using spectral libraries and previous studies of near-IR stellar spectra. We also use tabulated intrinsic stellar magnitudes and colors to derive distances and extinction values, and to better constrain the classifications of the stars. We reliably identify the central sources for 21 of the 55 MBs, which we classify as follows: one Wolf–Rayet, three luminous blue variable candidates, four early-type (O to F), and 15 late-type (G to M) stars. The 21 central sources are, on average, one magnitude fainter than these in the most recent study of MBs, and we notice a significant drop in the fraction of massive star candidates. For the 34 remaining MBs in our sample, we are unable to identify the central sources due to confusion, low spectroscopic signal-to-noise ratio, and/or lack of detections in the images near the centers of the bubbles. We discuss how our findings compare with previous studies and support the trend, for the most part, between the shells’ morphologies in the mid-IR and central sources spectral types.

  12. Crustal Deformation During the 2011 Volanic Crisis of El Hierro, Canary Islands, Revealed by Continuous GPS Observation

    Science.gov (United States)

    Sagiya, T.; Barrancos Martinez, J.; Calvo, D.; Padron, E.; Hernandez, G. H.; Hernández, P. A.; Perez Rodriguez, N.; Suárez, J. M. P.

    2012-04-01

    Seismo-volcnic activity of El Hierro started in the middle of July of 2011 and resulted in the active submarine eruption after October 12 south off La Restinga, the southern tip of the island. We have been operating one continuous GPS site on the island since 2004. Responding to the activity, we quickly installed 5 more GPS sites. Including another site operated by the Canary Islands Cartograhical Service (GRAFCAN) for a cartographic purpose, we have been monitoring 7 GPS sites equipped with dual-frequency receivers. We present the result of our crustal deformation monitoring and the magmatic activity inferred from the deformation data. In accordance with the deformation pattern, we divide the volcanic activity in 2011 into 4 stages. The first stage is from the middle of July to middle of September, during which steady magmatic inflation is estimated at the center of the island. The inflated volume of the first stage is estimated to be about 1.3 X 107 m3 at the depth of about 5km. The second stage, which continued until the first submarine eruption on October 12, is characterized by the accelerated deformation due to the upward as well as southward migration of magma. Additional inflation of about 2.1 X 107 m3 occurred in the depth range of 1-2km. The third stage continued for about 3 weeks after the first submarine eruption. During this stage, submarine eruption continues while no significant surface deformation is observed. It is considered magma supply from a deeper magma chamber continued during this 3 weeks period. Therefore, the total inflation volume during the first two stages gives the minimum estimate for the total magma volume. Since the beginning of November 2011, many GPS sites started subsiding. However, this deflation pattern is quite different from those in the shallow inflation stages. Horizontal deformation during this 4th stage is not significant, implying that deflation is occurring below the moho.

  13. Coronary Plaque Characterization in Psoriasis Reveals High-Risk Features That Improve After Treatment in a Prospective Observational Study.

    Science.gov (United States)

    Lerman, Joseph B; Joshi, Aditya A; Chaturvedi, Abhishek; Aberra, Tsion M; Dey, Amit K; Rodante, Justin A; Salahuddin, Taufiq; Chung, Jonathan H; Rana, Anshuma; Teague, Heather L; Wu, Jashin J; Playford, Martin P; Lockshin, Benjamin A; Chen, Marcus Y; Sandfort, Veit; Bluemke, David A; Mehta, Nehal N

    2017-07-18

    Psoriasis, a chronic inflammatory disease associated with an accelerated risk of myocardial infarction, provides an ideal human model to study inflammatory atherogenesis in vivo. We hypothesized that the increased cardiovascular risk observed in psoriasis would be partially attributable to an elevated subclinical coronary artery disease burden composed of noncalcified plaques with high-risk features. However, inadequate efforts have been made to directly measure coronary artery disease in this vulnerable population. As such, we sought to compare total coronary plaque burden and noncalcified coronary plaque burden (NCB) and high-risk plaque (HRP) prevalence between patients with psoriasis (n=105), patients with hyperlipidemia eligible for statin therapy under National Cholesterol Education Program-Adult Treatment Panel III guidelines (n=100) who were ≈10 years older, and healthy volunteers without psoriasis (n=25). Patients underwent coronary computed-tomography angiography for total coronary plaque burden and NCB quantification and HRP identification, defined as low attenuation (1.10), and spotty calcification. A consecutive sample of the first 50 patients with psoriasis was scanned again 1 year after therapy. Despite being younger and at lower traditional risk than patients with hyperlipidemia, patients with psoriasis had increased NCB (mean±SD: 1.18±0.33 versus 1.11±0.32, P =0.02) and similar HRP prevalence ( P =0.58). Furthermore, compared to healthy volunteers, patients with psoriasis had increased total coronary plaque burden (1.22±0.31 versus 1.04±0.22, P =0.001), NCB (1.18±0.33 versus 1.03±0.21, P =0.004), and HRP prevalence beyond traditional risk (odds ratio, 6.0; 95% confidence interval, 1.1-31.7; P =0.03). Last, among patients with psoriasis followed for 1 year, improvement in psoriasis severity was associated with improvement in total coronary plaque burden (β=0.45, 0.23-0.67; P psoriasis had greater NCB and increased HRP prevalence than

  14. Two crystal structures of dihydrofolate reductase-thymidylate synthase from Cryptosporidium hominis reveal protein–ligand interactions including a structural basis for observed antifolate resistance

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Amy C., E-mail: aca@dartmouth.edu [Dartmouth College, Department of Chemistry, Burke Laboratories, Hanover, NH 03755 (United States)

    2005-03-01

    An analysis of the protein–ligand interactions in two crystal structures of DHFR-TS from C. hominis reveals a possible structural basis for observed antifolate resistance in C. hominis DHFR. A comparison with the structure of human DHFR reveals residue substitutions that may be exploited for the design of species-selective inhibitors. Cryptosporidium hominis is a protozoan parasite that causes acute gastrointestinal illness. There are no effective therapies for cryptosporidiosis, highlighting the need for new drug-lead discovery. An analysis of the protein–ligand interactions in two crystal structures of dihydrofolate reductase-thymidylate synthase (DHFR-TS) from C. hominis, determined at 2.8 and 2.87 Å resolution, reveals that the interactions of residues Ile29, Thr58 and Cys113 in the active site of C. hominis DHFR provide a possible structural basis for the observed antifolate resistance. A comparison with the structure of human DHFR reveals active-site differences that may be exploited for the design of species-selective inhibitors.

  15. Structuring Consumer Preferences with the SEM Method

    OpenAIRE

    Rosa, Franco

    2002-01-01

    Structuring preferences has been developed with econometric models using functional flexible parametric form and the exploring the perceptions about expressed and latent needs using different multivariate approaches. Purpose of this research is to explore the demand for a new drink using the mean-end chain (MEC) theory and multivariate SEM procedure. The first part is dedicated to description of specialty foods for their capacity to create new niche markets. The MEC theory is introduced to ex...

  16. Bases de Datos Semánticas

    OpenAIRE

    Irving Caro Fierros; Víctor Hugo Menéndez Domínguez; María Enriqueta Castellanos Bolaños

    2016-01-01

    En 1992, cuando Tim Berners-Lee dio a conocer la primera  versión  de  la  Web,  su  visión  a  futuro  era  incorporar metadatos  con  información  semántica  en  las  páginas  Web.  Es precisamente   a   principios   de   este   siglo   que   inicia   el   auge repentino  de  la  Web  semántica  en  el  ambiente  académico  e Internet. El modelo de datos semántico se define como un modelo conceptual que permite definir el significado de los datos a través de  sus  relaciones  con  otros.  E...

  17. Characterization of Yeast Biofilm by Cryo-SEM and FIB-SEM

    Czech Academy of Sciences Publication Activity Database

    Hrubanová, Kamila; Nebesářová, Jana; Růžička, F.; Dluhoš, J.; Krzyžánek, Vladislav

    2013-01-01

    Roč. 19, S2 (2013), s. 226-227 ISSN 1431-9276 R&D Projects: GA MŠk EE.2.3.20.0103; GA TA ČR TE01020118; GA ČR GAP205/11/1687 Institutional support: RVO:68081731 ; RVO:60077344 Keywords : yeast biofilm * cryo-SEM * FIB-SEM Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.757, year: 2013

  18. An Expressive Bodily Movement Repertoire for Marimba Performance, Revealed through Observers' Laban Effort-Shape Analyses, and Allied Musical Features: Two Case Studies

    Science.gov (United States)

    Broughton, Mary C.; Davidson, Jane W.

    2016-01-01

    Musicians' expressive bodily movements can influence observers' perception of performance. Furthermore, individual differences in observers' music and motor expertise can shape how they perceive and respond to music performance. However, few studies have investigated the bodily movements that different observers of music performance perceive as expressive, in order to understand how they might relate to the music being produced, and the particular instrument type. In this paper, we focus on marimba performance through two case studies—one solo and one collaborative context. This study aims to investigate the existence of a core repertoire of marimba performance expressive bodily movements, identify key music-related features associated with the core repertoire, and explore how observers' perception of expressive bodily movements might vary according to individual differences in their music and motor expertise. Of the six professional musicians who observed and analyzed the marimba performances, three were percussionists and experienced marimba players. Following training, observers implemented the Laban effort-shape movement analysis system to analyze marimba players' bodily movements that they perceived as expressive in audio-visual recordings of performance. Observations that were agreed by all participants as being the same type of action at the same location in the performance recording were examined in each case study, then across the two studies. A small repertoire of bodily movements emerged that the observers perceived as being expressive. Movements were primarily allied to elements of the music structure, technique, and expressive interpretation, however, these elements appeared to be interactive. A type of body sway movement and more localized sound generating actions were perceived as expressive. These movements co-occurred and also appeared separately. Individual participant data revealed slightly more variety in the types and locations of actions

  19. An Expressive Bodily Movement Repertoire for Marimba Performance, Revealed through Observers' Laban Effort-Shape Analyses, and Allied Musical Features: Two Case Studies.

    Science.gov (United States)

    Broughton, Mary C; Davidson, Jane W

    2016-01-01

    Musicians' expressive bodily movements can influence observers' perception of performance. Furthermore, individual differences in observers' music and motor expertise can shape how they perceive and respond to music performance. However, few studies have investigated the bodily movements that different observers of music performance perceive as expressive, in order to understand how they might relate to the music being produced, and the particular instrument type. In this paper, we focus on marimba performance through two case studies-one solo and one collaborative context. This study aims to investigate the existence of a core repertoire of marimba performance expressive bodily movements, identify key music-related features associated with the core repertoire, and explore how observers' perception of expressive bodily movements might vary according to individual differences in their music and motor expertise. Of the six professional musicians who observed and analyzed the marimba performances, three were percussionists and experienced marimba players. Following training, observers implemented the Laban effort-shape movement analysis system to analyze marimba players' bodily movements that they perceived as expressive in audio-visual recordings of performance. Observations that were agreed by all participants as being the same type of action at the same location in the performance recording were examined in each case study, then across the two studies. A small repertoire of bodily movements emerged that the observers perceived as being expressive. Movements were primarily allied to elements of the music structure, technique, and expressive interpretation, however, these elements appeared to be interactive. A type of body sway movement and more localized sound generating actions were perceived as expressive. These movements co-occurred and also appeared separately. Individual participant data revealed slightly more variety in the types and locations of actions

  20. Human bloodstains on bone artefacts: an SEM intra- and inter-sample comparative study using ratite bird tibiotarsus.

    Science.gov (United States)

    Hortolà, Policarp

    2016-11-01

    Apart from their forensic significance in crime investigation, human bloodstains have an anthropological interest due to their occurrence on certain traditional weapons and ritual objects. Previously, a guiding study of erythrocytes in experimental samples including domestic sheep (Ovis aries) tibia was carried out using a scanning electron microscope (SEM). Here, a comparative SEM study to reveal the potential differences in bloodstain surface morphology as a function of intra-sample (smear region) and inter-sample (individual smear, smearing mechanism, bone origin) parameters is reported. A fragment of emu (Dromaius novaehollandiae) tibiotarsus was smeared with an adult man's peripheral blood. After air-drying and storing indoors, the boundary and neighbouring inner areas of the three individual bloodstains obtained were examined via secondary electrons in a variable-pressure SEM working in low-vacuum mode. As a whole, desiccation microcracks were present, the limits between the smear and the substrate appeared poorly defined, and no erythrocyte negative replicas were observed in the examined areas. In addition, a putative fibrin network, more or less embedded in the dried plasma matrix, was observed in the smears' boundary. Regarding the smear region in sliding smears, the periphery and boundary revealed to be different, while the head and tail were similar. Considering individual sliding smears, they had similar characteristics. Relating to the smear region as a function of the smearing mechanism, the periphery was different whether sliding or touching, while the boundary was similar in sliding and touching smears. Concerning the smear region as a function of the bone origin, the periphery revealed to be similar in both ratite and mammalian bone, while the boundary did different in ratite and mammalian bone. The results of this study show that SEM examination can be used fruitfully to detect bloodstains on ratite bone. Combined with previous SEM results in

  1. From patterns to causal understanding: Structural equation modeling (SEM) in soil ecology

    Science.gov (United States)

    Eisenhauer, Nico; Powell, Jeff R; Grace, James B.; Bowker, Matthew A.

    2015-01-01

    In this perspectives paper we highlight a heretofore underused statistical method in soil ecological research, structural equation modeling (SEM). SEM is commonly used in the general ecological literature to develop causal understanding from observational data, but has been more slowly adopted by soil ecologists. We provide some basic information on the many advantages and possibilities associated with using SEM and provide some examples of how SEM can be used by soil ecologists to shift focus from describing patterns to developing causal understanding and inspiring new types of experimental tests. SEM is a promising tool to aid the growth of soil ecology as a discipline, particularly by supporting research that is increasingly hypothesis-driven and interdisciplinary, thus shining light into the black box of interactions belowground.

  2. O ciberativismo sem bússola

    Directory of Open Access Journals (Sweden)

    Francisco Rüdiger

    2014-07-01

    Full Text Available Questiona-se no texto se uma abordagem que, no essencial, relata a trajetória do chamado ciberativismo de acordo com seus próprios termos se justifica academicamente ou, em vez disso, se mantém prisioneira de uma mitologia que o fenômeno, em si mesmo, já construiu e, por isso, autoriza seus sujeitos a dispensarem sem prejuízo eventual contribuição de origem universitária.

  3. Afasia global sem hemiparesia: relato de caso

    OpenAIRE

    SILVA,MARCUS TULIUS TEIXEIRA DA; CAVALCANTI,JOSÉ LUÍS DE SÁ; MOREIRA,DENISE MADEIRA

    2000-01-01

    Afasia global geralmente é acompanhada por hemiparesia direita devido à extensão da lesão subjacente. Recentemente têm sido registrados na literatura casos em que tal síndrome ou não se acompanha do déficit motor ou este é apenas transitório, sendo esta condição conhecida como afasia global sem hemiparesia (AGSH). Relatamos caso de AGSH devido a infarto cerebral embólico cardiogênico, corroborando a tese de que esta condição pode ter valor preditivo para o diagnóstico de infartos embólicos....

  4. Analysis of microtraces in invasive traumas using SEM/EDS.

    Science.gov (United States)

    Vermeij, E J; Zoon, P D; Chang, S B C G; Keereweer, I; Pieterman, R; Gerretsen, R R R

    2012-01-10

    Scanning electron microscopy in combination with energy-dispersive X-ray spectrometry (SEM/EDS) is a proven forensic tool and has been used to analyze several kinds of trace evidence. A forensic application of SEM/EDS is the examination of morphological characteristics of tool marks that tools and instruments leave on bone. The microtraces that are left behind by these tools and instruments on the bone are, however, often ignored or not noticed at all. In this paper we will describe the use of SEM/EDS for the analysis of microtraces in invasive sharp-force, blunt-force and bone-hacking traumas in bone. This research is part of a larger multi-disciplinary approach in which pathologists, forensic anthropologists, toolmark and microtrace experts work together to link observed injuries to a suspected weapon or, in case of an unknown weapon, to indicate a group of objects that could have been used as a weapon. Although there are a few difficulties one have to consider, the method itself is rather simple and straightforward to apply. A sample of dry and clean bone is placed into the SEM sample chamber and brightness and contrast are set such that bone appears grey, metal appears white and organic material appears black. The sample is then searched manually to find relevant features. Once features are found their elemental composition is measured by an energy dispersive X-ray spectrometer (EDS). This method is illustrated using several cases. It is shown that SEM/EDS analysis of microtraces in bone is a valuable tool to get clues about an unknown weapon and can associate a specific weapon with injuries on the basis of appearance and elemental composition. In particular the separate results from the various disciplines are complementary and may be combined to reach a conclusion with a stronger probative value. This is not only useful in the courtroom but above all in criminal investigations when one have to know for what weapon or object to look for. Copyright © 2011

  5. Sem-edx and ftir studies of chlorinated rubber coating

    International Nuclear Information System (INIS)

    Bano, H.; Khan, M.I.

    2013-01-01

    Summary: Anticorrosive performance of chlorinated rubber coating has been investigated by visual examination, Scanning electron microscopy (SEM)/Energy dispersive X-ray (EDX) analysis and Fourier transform infrared (FTIR) spectroscopy. After surface preparation, commercially available coating system based on chlorinated rubber (primer)/chlorinated rubber (topcoat) formulation was applied on mild steel test panels (10cm x 15cm sizes). Prepared coated panels were exposed at marine, industrial and urban test sites located in Karachi, Pakistan according to ISO 8565 norm. Accelerated testing was performed by using a salt spray chamber (ASTM B117 norm). Accelerated weathering methods are the methods in which the factors responsible for the degradation of coatings are artificially intensified in order to achieve the rapid degradation of coatings. Visual examination of blistering and rusting as well as SEM micrographs indicated a more severe degradation of the coating surface characteristics at natural exposure testing sites (particularly at marine test site) than for accelerated (salt spray) testing. EDX determination of the Oxygen/Carbon (O/C) ratios also indicated increased degradation at natural test sites compared to the accelerated (salt spray) testing. Photooxidation of the binder results in the formation of carbonyl compounds as revealed by FTIR spectroscopy which also indicated dehydrochlorination. (author)

  6. SEM method for direct visual tracking of nanoscale morphological changes of platinum based electrocatalysts on fixed locations upon electrochemical or thermal treatments.

    Science.gov (United States)

    Zorko, Milena; Jozinović, Barbara; Bele, Marjan; Hodnik, Nejc; Gaberšček, Miran

    2014-05-01

    A general method for tracking morphological surface changes on a nanometer scale with scanning electron microscopy (SEM) is introduced. We exemplify the usefulness of the method by showing consecutive SEM images of an identical location before and after the electrochemical and thermal treatments of platinum-based nanoparticles deposited on a high surface area carbon. Observations reveal an insight into platinum based catalyst degradation occurring during potential cycling treatment. The presence of chloride clearly increases the rate of degradation. At these conditions the dominant degradation mechanism seems to be the platinum dissolution with some subsequent redeposition on the top of the catalyst film. By contrast, at the temperature of 60°C, under potentiostatic conditions some carbon corrosion and particle aggregation was observed. Temperature treatment simulating the annealing step of the synthesis reveals sintering of small platinum based composite aggregates into uniform spherical particles. The method provides a direct proof of induced surface phenomena occurring on a chosen location without the usual statistical uncertainty in usual, random SEM observations across relatively large surface areas. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. El semáforo loco

    OpenAIRE

    González de Zachrisson, Hena

    2016-01-01

    El semáforo lo acababan de instalar en Vía Brasil y Calle 50 y estaba contento de poder mantener el orden del tránsito en tan importante calle. Sin embargo, pronto descubrió que su tarea no era fácil. Su territorio estaba atestado de muchachos que vendían frutas y vegetales y para escapar de ellos, los conductores hacían regatas para cruzar la calle antes de que la luz cambiara a rojo. —Todo a un dólar! —gritaban los chicos mostrando su bolsa de guineo, naranja, melón, maíz, papaya, c...

  8. In-situ SEM electrochemistry and radiolysis

    DEFF Research Database (Denmark)

    Møller-Nilsen, Rolf Erling Robberstad; Norby, Poul

    are backscattered and an image is reconstructed by the microscope. But the high energy electrons are a form of ionising radiation which can significantly affect the chemistry in liquid experiments. Ionising radiation can split water, produce radicals, reduce dissolved metal ions to metal particles, and more...... experiments. During the course of these studies it has also been possible to improve on the EC-SEM system. This has resulted in pyrolysed carbon electrodes, which offer the benefit of stability at 0.75 V higher potentials than traditional gold thin-film electrodes. With the quantitative insight...... microelectrodes on the windows to enable studies of electrohcemical processes. In this way it is possible to perform in-situ electrochemical experiments such as electroplating and charge and discharge analysis of battery electrodes. In a typical liquid cell, electrons are accelerated to sufficiently high energies...

  9. Developing 3D SEM in a broad biological context

    Science.gov (United States)

    Kremer, A; Lippens, S; Bartunkova, S; Asselbergh, B; Blanpain, C; Fendrych, M; Goossens, A; Holt, M; Janssens, S; Krols, M; Larsimont, J-C; Mc Guire, C; Nowack, MK; Saelens, X; Schertel, A; Schepens, B; Slezak, M; Timmerman, V; Theunis, C; Van Brempt, R; Visser, Y; GuÉRin, CJ

    2015-01-01

    When electron microscopy (EM) was introduced in the 1930s it gave scientists their first look into the nanoworld of cells. Over the last 80 years EM has vastly increased our understanding of the complex cellular structures that underlie the diverse functions that cells need to maintain life. One drawback that has been difficult to overcome was the inherent lack of volume information, mainly due to the limit on the thickness of sections that could be viewed in a transmission electron microscope (TEM). For many years scientists struggled to achieve three-dimensional (3D) EM using serial section reconstructions, TEM tomography, and scanning EM (SEM) techniques such as freeze-fracture. Although each technique yielded some special information, they required a significant amount of time and specialist expertise to obtain even a very small 3D EM dataset. Almost 20 years ago scientists began to exploit SEMs to image blocks of embedded tissues and perform serial sectioning of these tissues inside the SEM chamber. Using first focused ion beams (FIB) and subsequently robotic ultramicrotomes (serial block-face, SBF-SEM) microscopists were able to collect large volumes of 3D EM information at resolutions that could address many important biological questions, and do so in an efficient manner. We present here some examples of 3D EM taken from the many diverse specimens that have been imaged in our core facility. We propose that the next major step forward will be to efficiently correlate functional information obtained using light microscopy (LM) with 3D EM datasets to more completely investigate the important links between cell structures and their functions. Lay Description Life happens in three dimensions. For many years, first light, and then EM struggled to image the smallest parts of cells in 3D. With recent advances in technology and corresponding improvements in computing, scientists can now see the 3D world of the cell at the nanoscale. In this paper we present the

  10. Diabetic patients with and without peripheral neuropathy reveal different hip and ankle biomechanical strategies during stair descent Pacientes diabéticos com e sem a neuropatia periférica mostram diferentes estratégias biomecânicas de quadril e tornozelo ao descer escada

    Directory of Open Access Journals (Sweden)

    Andreja P. Picon

    2012-12-01

    Full Text Available BACKGROUND: The progression of diabetes and the challenge of daily tasks may result in changes in biomechanical strategies. Descending stairs is a common task that patients have to deal with, however it still has not been properly studied in this population. OBJECTIVES: We describe and compare the net joint moments and kinematics of the lower limbs in diabetic individuals with and without peripheral neuropathy and healthy controls during stair descent. METHOD: Forty-two adults were assessed: control group (13, diabetic group (14, and neuropathic diabetic group (15. The flexor and extensor net moment peaks and joint angles of the hip, knee, and ankle were described and compared in terms of effect size and ANOVAs (pCONTEXTUALIZAÇÃO: A progressão do Diabetes Mellito e as atividades desafiadoras do dia a dia podem resultar em mudanças da estratégia biomecânica adotada. Descer escadas é uma tarefa comum do dia a dia, vivenciada pelos pacientes, mas ainda não foi satisfatoriamente estudada nessa população. OBJECTIVOS: Descrever e comparar os momentos articulares e a cinemática de membros inferiores em indivíduos diabéticos com e sem a neuropatia periférica e controles saudáveis durante o descer escadas. MÉTODO: Quarenta e dois adultos foram avaliados: grupo controle (13, grupo diabético (15 e grupo de diabéticos neuropatas (14. Os picos flexores e extensores dos momentos articulares e os ângulos articulares de quadril, joelho e tornozelo foram comparados e descritos por análise do tamanho do efeito e ANOVAs (p<0,05. RESULTADOS: Na fase de aceitação do peso, ambos os grupos diabéticos apresentaram maior ângulo de dorsiflexão de tornozelo [tamanho de efeito grande] e menor momento extensor de quadril [tamanho de efeito grande]. Na fase de propulsão, diabéticos com e sem a neuropatia apresentaram maior momento flexor de quadril [tamanho de efeito grande] e menor ângulo de extensão de tornozelo [tamanho de efeito grande

  11. Diabetic patients with and without peripheral neuropathy reveal different hip and ankle biomechanical strategies during stair descent Pacientes diabéticos com e sem a neuropatia periférica mostram diferentes estratégias biomecânicas de quadril e tornozelo ao descer escada

    Directory of Open Access Journals (Sweden)

    Andreja P. Picon

    2012-01-01

    Full Text Available BACKGROUND: The progression of diabetes and the challenge of daily tasks may result in changes in biomechanical strategies. Descending stairs is a common task that patients have to deal with, however it still has not been properly studied in this population. OBJECTIVES: We describe and compare the net joint moments and kinematics of the lower limbs in diabetic individuals with and without peripheral neuropathy and healthy controls during stair descent. METHOD: Forty-two adults were assessed: control group (13, diabetic group (14, and neuropathic diabetic group (15. The flexor and extensor net moment peaks and joint angles of the hip, knee, and ankle were described and compared in terms of effect size and ANOVAs (pCONTEXTUALIZAÇÃO: A progressão do Diabetes Mellito e as atividades desafiadoras do dia a dia podem resultar em mudanças da estratégia biomecânica adotada. Descer escadas é uma tarefa comum do dia a dia, vivenciada pelos pacientes, mas ainda não foi satisfatoriamente estudada nessa população. OBJECTIVOS: Descrever e comparar os momentos articulares e a cinemática de membros inferiores em indivíduos diabéticos com e sem a neuropatia periférica e controles saudáveis durante o descer escadas. MÉTODO: Quarenta e dois adultos foram avaliados: grupo controle (13, grupo diabético (15 e grupo de diabéticos neuropatas (14. Os picos flexores e extensores dos momentos articulares e os ângulos articulares de quadril, joelho e tornozelo foram comparados e descritos por análise do tamanho do efeito e ANOVAs (p<0,05. RESULTADOS: Na fase de aceitação do peso, ambos os grupos diabéticos apresentaram maior ângulo de dorsiflexão de tornozelo [tamanho de efeito grande] e menor momento extensor de quadril [tamanho de efeito grande]. Na fase de propulsão, diabéticos com e sem a neuropatia apresentaram maior momento flexor de quadril [tamanho de efeito grande] e menor ângulo de extensão de tornozelo [tamanho de efeito grande

  12. A detailed TEM and SEM study of Ni-base alloys oxide scales formed in primary conditions of pressurized water reactor

    International Nuclear Information System (INIS)

    Sennour, Mohamed; Marchetti, Loic; Martin, Frantz; Perrin, Stephane; Molins, Regine; Pijolat, Michele

    2010-01-01

    The oxide film formed on nickel-based alloys in pressurized water reactors (PWR) primary coolant conditions (325 o C, aqueous media) is very thin, in the range of 1-100 nm thick, depending on the surface state and on the corrosion test duration. The nature and the structure of this scale have been investigated by Transmission Electron Microscopy (TEM) and Scanning Electron Microscopy (SEM). TEM observations revealed an oxide layer divided in two parts. The internal layer was mainly composed of a continuous spinel layer, identified as a mixed iron and nickel chromite (Ni (1-x) Fe x Cr 2 O 4 ). Moreover, nodules of Cr 2 O 3 , with a size about 5 nm, were present at the interface between this spinel and the alloy. No chromium depletion was observed in the alloy, at the alloy/oxide interface. The external layer is composed of large crystallites corresponding to a spinel structure rich in iron (Ni (1-z) Fe (2+z) O 4 ) resulting from precipitation phenomena. SEM and TEM observations showed a link between the nucleation and/or the growth of crystallites of nickel ferrite and the crystallographic orientation of the substrate. A link between the presence of surface defects and the nucleation of the crystallites was also underlined by SEM observations. Partially hydrated nickel hydroxide, was also observed by TEM in the external scale. Based on these results, some considerations about the mechanism of formation of this oxide layer are discussed.

  13. The life and death of massive stars revealed by the observation of nuclear gamma-ray lines with the Integral/SPI spectrometer

    International Nuclear Information System (INIS)

    Martin, P.

    2008-11-01

    The aim of this research thesis is to bring up observational constraints on the mechanisms which govern life and death of massive stars, i.e. stars having an initial mass greater than eight times the Sun's mass, and smaller than 120 to 150 solar masses. Thus, it aims at detecting the vestiges of recent and close supernovae in order to find out the traces of the dynamics of their first instants. The author has explored the radiation of three radio-isotopes accessible to the nuclear gamma astronomy ( 44 Ti, 60 Fe, 26 Al) using observations performed with high resolution gamma spectrometer (SPI) on the INTEGRAL international observatory. After an overview of the present knowledge on the massive star explosion mechanism, the author presents the specificities and potential of the investigated radio-isotopes. He describes the data treatment methods and a population synthesis programme for the prediction of decay gamma streaks, and then reports its work on the inner dynamics of Cassiopeia A explosion, the stellar activity of the galaxy revealed by the radioisotope observation, the nucleo-synthetic activity of the Swan region

  14. A brief discussion about image quality and SEM methods for quantitative fractography of polymer composites.

    Science.gov (United States)

    Hein, L R O; Campos, K A; Caltabiano, P C R O; Kostov, K G

    2013-01-01

    The methodology for fracture analysis of polymeric composites with scanning electron microscopes (SEM) is still under discussion. Many authors prefer to use sputter coating with a conductive material instead of applying low-voltage (LV) or variable-pressure (VP) methods, which preserves the original surfaces. The present work examines the effects of sputter coating with 25 nm of gold on the topography of carbon-epoxy composites fracture surfaces, using an atomic force microscope. Also, the influence of SEM imaging parameters on fractal measurements is evaluated for the VP-SEM and LV-SEM methods. It was observed that topographic measurements were not significantly affected by the gold coating at tested scale. Moreover, changes on SEM setup leads to nonlinear outcome on texture parameters, such as fractal dimension and entropy values. For VP-SEM or LV-SEM, fractal dimension and entropy values did not present any evident relation with image quality parameters, but the resolution must be optimized with imaging setup, accompanied by charge neutralization. © Wiley Periodicals, Inc.

  15. SEM investigation of incandescent lamp mantle structure on durability

    International Nuclear Information System (INIS)

    Gerneke, D.; Lang, C.

    2002-01-01

    Full text: The incandescent mantle as used on pressure and non-pressure liquid fuel lamps has been in use for over 100 years. What remains unexplained is the way in which the resistance to mechanical shock and the decline in tensile strength with usage is experienced. It has been suggested that to improve durability it is necessary to continuously burn a new mantle for the first two to three hours. The known factors in mantle durability and mechanical strength are chemical composition and fabric weave. This study was undertaken to investigate the effects of burning time and temperature on thorium oxide mantles. The operating temperature of mantles on a range of kerosene pressure lamps was measured and found to be between 800 and 1100 deg C. Heat treatments of thorium based Coleman mantles were carried out in a laboratory furnace within these ranges of temperatures for periods ranging from 2 minutes to 2 hours. The mantles were then viewed in a LEO S440 analytical SEM. Results at 800 deg C show a distinct change in surface morphology with increasing exposure time. At the shorter times (2-5 minutes) the surface was relatively smooth. With increased time periods (15 - 120 minutes) the surface was observed to have a large lumpy structure. At 1100 deg C the difference in surface morphology was not apparent between the shortest and longest times. The surface appears much smoother and no lumpy structure was observed. This suggests that when a mantle is operated at the higher temperature of 1100 deg C the structure of the Thorium oxide is quickly transformed into the known stronger amorphous form. This is taken as the observed smooth structure seen in the SEM images of the 1100 deg C samples. Thus the mantle is expected to be more resistant to mechanical shock and have increased durability. Practical field test results confirm these observations. The mantle on a lamp that is operating efficiently, burns brightly, will far outlast a mantle on an inefficient lamp which bums

  16. Revealing Interactions between Human Resources, Quality of Life and Environmental Changes within Socially-oriented Observations : Results from the IPY PPS Arctic Project in the Russian North

    Science.gov (United States)

    Vlasova, Tatiana

    2010-05-01

    Socially-oriented Observations (SOO) in the Russian North have been carried out within multidisciplinary IPY PPS Arctic project under the leadership of Norway and supported by the Research Council of Norway as well as Russian Academy of Sciences. The main objective of SOO is to increase knowledge and observation of changes in quality of life conditions (state of natural environment including climate and biota, safe drinking water and foods, well-being, employment, social relations, access to health care and high quality education, etc.) and - to reveal trends in human capital and capacities (health, demography, education, creativity, spiritual-cultural characteristics and diversity, participation in decision making, etc.). SOO have been carried out in industrial cities as well as sparsely populated rural and nature protection areas in observation sites situated in different bioms (from coastal tundra to southern taiga zone) of Murmansk, Arkhangelsk Oblast and Republic of Komi. SOO were conducted according to the international protocol included in PPS Arctic Manual. SOO approaches based both on local people's perceptions and statistics help to identify main issues and targets for life quality, human capital and environment improvement and thus to distinguish leading SOO indicators for further monitoring. SOO have revealed close interaction between human resources, quality of life and environmental changes. Negative changes in human capital (depopulation, increasing unemployment, aging, declining physical and mental health, quality of education, loss of traditional knowledge, marginalization etc.), despite peoples' high creativity and optimism are becoming the major driving force effecting both the quality of life and the state of environment and overall sustainability. Human induced disturbances such as uncontrolled forests cuttings and poaching are increasing. Observed rapid changes in climate and biota (ice and permafrost melting, tundra shrubs getting taller and

  17. Comparative SEM analysis of nine F22 aligner cleaning strategies.

    Science.gov (United States)

    Lombardo, Luca; Martini, Marco; Cervinara, Francesca; Spedicato, Giorgio Alfredo; Oliverio, Teresa; Siciliani, Giuseppe

    2017-12-01

    The orthodontics industry has paid great attention to the aesthetics of orthodontic appliances, seeking to make them as invisible as possible. There are several advantages to clear aligner systems, including aesthetics, comfort, chairside time reduction, and the fact that they can be removed for meals and oral hygiene procedures. Five patients were each given a series of F22 aligners, each to be worn for 14 days and nights, with the exception of meal and brushing times. Patients were instructed to clean each aligner using a prescribed strategy, and sections of the used aligners were observed under SEM. One grey-scale SEM image was saved per aligner in JPEG format with an 8-bit colour depth, and a total of 45 measurements on the grey scale ("Value" variable) were made. This dataset was analysed statistically via repeated measures ANOVA to determine the effect of each of the nine cleaning strategies in each of the five patients. A statistically significant difference in the efficacy of the cleaning strategies was detected. Specifically, rinsing with water alone was significantly less efficacious, and a combination of cationic detergent solution and ultrasonication was significantly more efficacious than the other methods (p aligners.

  18. Analysis list: sem-4 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available sem-4 Larvae + ce10 http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/target/sem-4.1....tsv http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/target/sem-4.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/target/sem...-4.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/colo/sem-4.Larvae.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/ce10/colo/Larvae.gml ...

  19. Performance of SEM scintillation detector evaluated by modulation transfer function and detective quantum efficiency function.

    Science.gov (United States)

    Bok, Jan; Schauer, Petr

    2014-01-01

    In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector's influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated e-beam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart-Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the e-beam scan. The results demonstrate the great benefit of the description of SEM detectors using the MTF and DQE. In addition, point-by-point and continual-sweep e-beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF. © 2013 Wiley Periodicals, Inc.

  20. Stirling Energy Module (SEM) as Micro-CHP; Stirling Energy Module (SEM) als Mini-BHKW

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, A.

    2006-07-01

    Since many years, a lot of effort is being put into the development of combined heat and power units (CHP) for the decentralised production of electric power. For long time, the main focus was on fuel cells. In the meantime, the Stirling technology, which is based upon classical mechanical engineering and innovative technical concepts, proceeded in its development as well. The following article describes the technology and the actual state of the development of the Stirling Energy Module (SEM) for the application as Micro-CHP in one-family-houses. SEM is based on a free-piston engine with a linear power generator, producing electric power while heating. The Stirling engine is planned the be introduced into the market as a replacement for the conventional heating systems within a couple of years. (author)

  1. Mantle wedge structure beneath the Yamato Basin, southern part of the Japan Sea, revealed by long-term seafloor seismic observations

    Science.gov (United States)

    Shinohara, M.; Nakahigashi, K.; Yamashita, Y.; Yamada, T.; Mochizuki, K.; Shiobara, H.

    2016-12-01

    The Japanese Islands are located at subduction zones where Philippine Sea (PHS) plate subducts from the southeast beneath the Eurasian plate and the Pacific plate descends from the east beneath the PHS and Eurasian plates and have a high density of seismic stations. Many seismic tomography studies using land seismic station data were conducted to reveal the seismic structure. These studies discussed the relationship between heterogeneous structures and the release of fluids from the subducting slab, magma generation and movement in the subduction zone. However, regional tomography using the land station data did not have a sufficient resolution to image a deep structure beneath the Japan Sea.To obtain the deep structure, observations of natural earthquakes within the Japan Sea are essential. Therefore, we started the repeating long-term seismic observations using ocean bottom seismometers(OBSs) in the Yamato Basin from 2013 to 2016. We apply travel-time tomography method to the regional earthquake and teleseismic arrival-data recorded by OBSs and land stations. In this presentation, we will report the P and S wave tomographic images down to a depth of 300 km beneath the southern part of the Japan Sea. This study was supported by "Integrated Research Project on Seismic and Tsunami Hazards around the Sea of Japan" conducted by the Ministry of Education, Culture, Sports, Science, and Technology (MEXT) of Japan.

  2. Why semicarbazide (SEM) is not an appropriate marker for the usage of nitrofurazone on agricultural animals.

    Science.gov (United States)

    Stadler, Richard H; Verzegnassi, Ludovica; Seefelder, Walburga; Racault, Lucie

    2015-01-01

    A comprehensive global database on semicarbazide (SEM) in foodstuffs and food ingredients is presented, with over 4000 data collected in foods such as seafood (crustaceans, fish powders), meat (beef, chicken powders), dairy products (e.g. raw milk, milk powders, whey, sweet buttermilk powder, caseinate, yoghurt, cheese), honey and other ingredients. The results provide evidence that the presence of SEM in certain dairy ingredients (whey, milk protein concentrates) is a by-product of chemical reactions taking place during the manufacturing process. Of the dairy ingredients tested (c. 2000 samples), 5.3% showed traces of SEM > 0.5 µg/kg. The highest incidence of SEM-positive samples in the dairy category were whey (powders, liquid) and milk protein concentrates (35% positive), with up to 13 µg/kg measured in a whey powder. Sweet buttermilk powder and caseinate followed, with 27% and 9.3% positives, respectively. SEM was not detected in raw milk, or in yoghurt or cheese. Of the crustacean products (shrimp and prawn powders) tested, 44% were positive for SEM, the highest value measured at 284 µg/kg. Fish powders revealed an unexpectedly high incidence of positive samples (25%); in this case, fraudulent addition of shellfish shells or carry-over during processing cannot be excluded. Overall, the data provide new insights into the occurrence of SEM (for dairy products and fish powders), substantially strengthening the arguments that SEM in certain food categories is not a conclusive marker of the use of the illegal antibiotic nitrofurazone.

  3. Information or resolution: Which is required from an SEM to study bulk inorganic materials?

    Science.gov (United States)

    Xing, Q

    2016-11-01

    Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. The electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energy-dispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. For an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly improve the usability of the SEM. SCANNING 38:864-879, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

  4. Tillandsia stricta Sol (Bromeliaceae) leaves as monitors of airborne particulate matter-A comparative SEM methods evaluation: Unveiling an accurate and odd HP-SEM method.

    Science.gov (United States)

    de Oliveira, Martha Lima; de Melo, Edésio José Tenório; Miguens, Flávio Costa

    2016-09-01

    Airborne particulate matter (PM) has been included among the most important air pollutants by governmental environment agencies and academy researchers. The use of terrestrial plants for monitoring PM has been widely accepted, particularly when it is coupled with SEM/EDS. Herein, Tillandsia stricta leaves were used as monitors of PM, focusing on a comparative evaluation of Environmental SEM (ESEM) and High-Pressure SEM (HPSEM). In addition, specimens air-dried at formaldehyde atmosphere (AD/FA) were introduced as an SEM procedure. Hydrated specimen observation by ESEM was the best way to get information from T. stricta leaves. If any artifacts were introduced by AD/FA, they were indiscernible from those caused by CPD. Leaf anatomy was always well preserved. PM density was determined on adaxial and abaxial leaf epidermis for each of the SEM proceedings. When compared with ESEM, particle extraction varied from 0 to 20% in air-dried leaves while 23-78% of particles deposited on leaves surfaces were extracted by CPD procedures. ESEM was obviously the best choice over other methods but morphological artifacts increased in function of operation time while HPSEM operation time was without limit. AD/FA avoided the shrinkage observed in the air-dried leaves and particle extraction was low when compared with CPD. Structural and particle density results suggest AD/FA as an important methodological approach to air pollution biomonitoring that can be widely used in all electron microscopy labs. Otherwise, previous PM assessments using terrestrial plants as biomonitors and performed by conventional SEM could have underestimated airborne particulate matter concentration. © 2016 Wiley Periodicals, Inc.

  5. Comparative SEM analysis of nine F22 aligner cleaning strategies

    Directory of Open Access Journals (Sweden)

    Luca Lombardo

    2017-09-01

    Full Text Available Abstract Background The orthodontics industry has paid great attention to the aesthetics of orthodontic appliances, seeking to make them as invisible as possible. There are several advantages to clear aligner systems, including aesthetics, comfort, chairside time reduction, and the fact that they can be removed for meals and oral hygiene procedures. Methods Five patients were each given a series of F22 aligners, each to be worn for 14 days and nights, with the exception of meal and brushing times. Patients were instructed to clean each aligner using a prescribed strategy, and sections of the used aligners were observed under SEM. One grey-scale SEM image was saved per aligner in JPEG format with an 8-bit colour depth, and a total of 45 measurements on the grey scale (“Value” variable were made. This dataset was analysed statistically via repeated measures ANOVA to determine the effect of each of the nine cleaning strategies in each of the five patients. Results A statistically significant difference in the efficacy of the cleaning strategies was detected. Specifically, rinsing with water alone was significantly less efficacious, and a combination of cationic detergent solution and ultrasonication was significantly more efficacious than the other methods (p < 0.05. Conclusions Of the nine cleaning strategies examined, only that involving 5 min of ultrasonication at 42 k Hz combined with a 0.3% germicidal cationic detergent was observed to be statistically effective at removing the bacterial biofilm from the surface of F22 aligners.

  6. PAT and SEM study of porous silicon formed by anodization methods

    International Nuclear Information System (INIS)

    Liu Jian; Wei Long; Wang Huiyao; Ma Chuangxin; Wang Baoyi

    2000-01-01

    The porous silicon formed by anodization of crystal silicon was studied by positron annihilation technique (PAT) and scanning electron microscopy (SEM). The PAT experiments showed that the mean life and vacancy defects increased with the increasing anodization time. While the intensities of the longest lifetime, several ns-tens ns (ortho-positronium) dropped down. Small single-crystal Si spheres with mean radius of a few μm were observed by SEM after anodization. Pits with mean radius of a few μm from the divorcement of single-crystal spheres were also observed after further anodization. The increases of vacancy defects might be that the extension of structures of porous silicon towards inner layer with anodization time and caused more vacancy defects in inner layer. The SEM observation presented another possibility of the increase of density of vacancy defects in surface layer induced by the change of structures

  7. SemEval-2016 task 10

    DEFF Research Database (Denmark)

    Schneider, Nathan; Hovy, Dirk; Johannsen, Anders Trærup

    2016-01-01

    This task combines the labeling of multiword expressions and supersenses (coarse-grained classes) in an explicit, yet broad-coverage paradigm for lexical semantics. Nine systems participated; the best scored 57.7% F1 in a multi-domain evaluation setting, indicating that the task remains largely...... unresolved. An error analysis reveals that a large number of instances in the data set are either hard cases, which no systems get right, or easy cases, which all systems correctly solve....

  8. A SEM-correlation of the anatomy of the vitreous body: making visible the invisible.

    Science.gov (United States)

    Jongebloed, W L; Humalda, D; Worst, J F

    1986-12-30

    The naked human vitreous (sclera, iris and cornea removed) suspended in water does not reveal inner structures. After ink injection into the vitreous, the presence of different compartments and the existence of cisterns becomes evident. A concept of the internal system of cisterns is given on the basis of stereoscopic-lightmicroscopic images. An attempt is made to correlate images of the complete vitreous body, obtained with a stereo-lightmicroscope, with images of segments of cisternal walls produced with a scanning electron-microscope (SEM). A comparison is made between SEM-images of the vitreous bodies of human and rabbit eyes.

  9. SEM examination and analysis of the interface character in surface modified aramid-epoxy composite

    International Nuclear Information System (INIS)

    Hussain, S.; Khan, M.B.; Hussain, R.

    2011-01-01

    The surface of Kevlar fibers is chemically modified by treatment with Phthalic anhydride (PA) and the effect is examined by SEM for the laser cut, three point bending and interlaminar shear delaminated surfaces. The surface modification improved the adhesion to epoxy resin that clearly leads to cohesive fracture as opposed to interfacial failure in the untreated specimen. SEM reveals marginal surface roughening of fibers without compromising their strength. The interface modification technique described in this paper is attractive thermodynamically as it does not compromise surface free energy of the polymer matrix or that of the fiber itself to enhance wet ability. (author)

  10. SEM analysis of ionizing radiation effects in linear integrated circuits. [Scanning Electron Microscope

    Science.gov (United States)

    Stanley, A. G.; Gauthier, M. K.

    1977-01-01

    A successful diagnostic technique was developed using a scanning electron microscope (SEM) as a precision tool to determine ionization effects in integrated circuits. Previous SEM methods radiated the entire semiconductor chip or major areas. The large area exposure methods do not reveal the exact components which are sensitive to radiation. To locate these sensitive components a new method was developed, which consisted in successively irradiating selected components on the device chip with equal doses of electrons /10 to the 6th rad (Si)/, while the whole device was subjected to representative bias conditions. A suitable device parameter was measured in situ after each successive irradiation with the beam off.

  11. Cross-Sectional Information on Pore Structure and Element Distribution of Sediment Particles by SEM and EDS

    Directory of Open Access Journals (Sweden)

    Minghong Chen

    2017-01-01

    Full Text Available The interaction between pollutants and sediment particles often occurs on the particle surface, so surface properties directly affect surface reaction. The physical and chemical processes occurring on sediment particle surfaces are microscopic processes and as such need to be studied from a microscopic perspective. In this study, field emission scanning electron microscopy (SEM and energy dispersive X-ray spectrometer (EDS were adopted to observe and analyze the pore structure and element distribution of sediment particles. In particular, a special method of sample preparation was used to achieve the corresponding cross-sectional information of sediment particles. Clear images of a particle profile and pore microstructure were obtained by high-resolution SEM, while element distribution maps of sediment particles were obtained by EDS. The results provide an intuitive understanding of the internal microenvironment and external behavior of sediment particles, in addition to revealing a significant role of pore microstructure in the adsorption and desorption of pollutants. Thus, a combination of different experimental instruments and observation methods can provide real images and information on microscopic pore structure and element distribution of sediment particles. These results should help to improve our understanding of sediment dynamics and its environmental effects.

  12. Canticum Novum: música sem palavras e palavras sem som no pensamento de Santo Agostinho

    Directory of Open Access Journals (Sweden)

    Lorenzo Mammì

    2000-04-01

    Full Text Available NO De Magistro, Santo Agostinho coloca a reza e o canto numa posição similar, à margem das funções imediatamente comunicativas da linguagem. A reflexão agostiniana sobre a reza se baseia nos hábitos cristãos da leitura, da oração e da meditação silenciosas. Há sobre o canto, na prática igualmente inovadora do jubilus, melodia sem palavra destinada aos momentos mais intensos e gaudiosos da liturgia. A oração silenciosa e o jubilus são temas recorrentes da literatura patrística, mas Agostinho os aborda de maneira original, desenhando, a partir das palavras sem som da oração e do som sem palavra do jubilus, o perfil de um discurso interior, que não se destina aos homens, mas a Deus.IN HIS De Magistro Saint Augustine places prayer and song on a similar level, alongside the language immediately communicative functions. His considerations on prayer are grounded on the Christian habits of silent reading, prayer and meditation; those on song, on the equally innovating practice called jubilus, which is melody without words designed for the intensest and most joyous liturgical moments. Silent prayer and jubilus are recurring topics in patristic literature, but Augustine deals with them in an original way, drawing from the soundless words of prayer and the wordless sound of jubilus an inner discourse, addressed not to men but to God.

  13. In situ camera observations reveal major role of zooplankton in modulating marine snow formation during an upwelling-induced plankton bloom

    Science.gov (United States)

    Taucher, Jan; Stange, Paul; Algueró-Muñiz, María; Bach, Lennart T.; Nauendorf, Alice; Kolzenburg, Regina; Büdenbender, Jan; Riebesell, Ulf

    2018-05-01

    Particle aggregation and the consequent formation of marine snow alter important properties of biogenic particles (size, sinking rate, degradability), thus playing a key role in controlling the vertical flux of organic matter to the deep ocean. However, there are still large uncertainties about rates and mechanisms of particle aggregation, as well as the role of plankton community structure in modifying biomass transfer from small particles to large fast-sinking aggregates. Here we present data from a high-resolution underwater camera system that we used to observe particle size distributions and formation of marine snow (aggregates >0.5 mm) over the course of a 9-week in situ mesocosm experiment in the Eastern Subtropical North Atlantic. After an oligotrophic phase of almost 4 weeks, addition of nutrient-rich deep water (650 m) initiated the development of a pronounced diatom bloom and the subsequent formation of large marine snow aggregates in all 8 mesocosms. We observed a substantial time lag between the peaks of chlorophyll a and marine snow biovolume of 9-12 days, which is much longer than previously reported and indicates a marked temporal decoupling of phytoplankton growth and marine snow formation during our study. Despite this time lag, our observations revealed substantial transfer of biomass from small particle sizes (single phytoplankton cells and chains) to marine snow aggregates of up to 2.5 mm diameter (ESD), with most of the biovolume being contained in the 0.5-1 mm size range. Notably, the abundance and community composition of mesozooplankton had a substantial influence on the temporal development of particle size spectra and formation of marine snow aggregates: While higher copepod abundances were related to reduced aggregate formation and biomass transfer towards larger particle sizes, the presence of appendicularia and doliolids enhanced formation of large marine snow. Furthermore, we combined in situ particle size distributions with

  14. SEM and HRTEM study of porous silicon--relationship between fabrication, morphology and optical properties

    International Nuclear Information System (INIS)

    Dian, J.; Macek, A.; Niznansky, D.; Nemec, I.; Vrkoslav, V.; Chvojka, T.; Jelinek, I.

    2004-01-01

    We studied the dependence of porous silicon (PS) morphology on fabrication conditions and the link between morphology, porosity and optical properties. P-type (1 0 0) silicon wafers with resistivity of 10 Ω cm were electrochemically etched in a HF:ethanol:water mixture at various HF concentrations and current densities. Porosity and thickness of the samples were determined gravimetrically. Detailed information about evolution of porous silicon layer morphology with variation of preparation conditions was obtained by scanning electron microscope (SEM), the presence of silicon nanoparticles was confirmed by high resolution transmission electron microscopy. Decrease of the mean size of silicon nanoparticles with increasing porous silicon porosity was revealed in a monotonous blue shift of photoluminescence (PL) maximum in room temperature photoluminescence spectra of studied samples. This blue shift is consistent with quantum confinement model of photoluminescence mechanism. We observed that total porosity of porous films cannot fully explain observed photoluminescence behavior and correct interpretation of the blue shift of photoluminescence spectra requires detailed knowledge of porous silicon morphology

  15. Effects of regional-scale and convective transports on tropospheric ozone chemistry revealed by aircraft observations during the wet season of the AMMA campaign

    Directory of Open Access Journals (Sweden)

    G. Ancellet

    2009-01-01

    Full Text Available The African Monsoon Multidisciplinary Analyses (AMMA fourth airborne campaign was conducted in July–August 2006 to study the chemical composition of the middle and upper troposphere in West Africa with the major objective to better understand the processing of chemical emissions by the West African Monsoon (WAM and its associated regional-scale and vertical transports. In particular, the french airborne experiment was organized around two goals. The first was to characterize the impact of Mesoscale Convective Systems (MCSs on the ozone budget in the upper troposphere and the evolution of the chemical composition of these convective plumes as they move westward toward the Atlantic Ocean. The second objective was to discriminate the impact of remote sources of pollution over West Africa, including transport from the middle east, Europe, Asia and from southern hemispheric fires. Observations of O3, CO, NOx, H2O and hydroperoxide above West Africa along repeated meridional transects were coupled with transport analysis based on the FLEXPART lagrangian model. The cross analysis of trace gas concentrations and transport pathways revealed 5 types of air masses: convective uplift of industrial and urban emissions, convective uplift of biogenic emissions, slow advection from Cotonou polluted plumes near the coast, meridional transport of upper tropospheric air from the subtropical barrier region, and meridional transport of Southern Hemisphere (SH biomass burning emissions. O3/CO correlation plots and the correlation plots of H2O2 with a OH proxy revealed not only a control of the trace gas variability by transport processes but also significant photochemical reactivity in the mid- and upper troposphere. The study of four MCSs outflow showed contrasted chemical composition and air mass origins depending on the MCSs lifetime and latitudinal position. Favorables conditions for ozone

  16. The importance of scanning electron microscopy (sem in taxonomy and morphology of Chironomidae (Diptera

    Directory of Open Access Journals (Sweden)

    Andrzej Kownacki

    2015-07-01

    Full Text Available The paper reports on the value of scanning electron microscopy (SEM in the taxonomy and morphology of Chironomidae. This method has been relatively rarely used in Chironomidae studies. Our studies suggest that the SEM method provides a lot of new information. For example, the plastron plate of the thoracic horn of Macropelopia nebulosa (Meigen under light microscopy is visible as points, while under SEM we have found that it consists of a reticular structure with holes. By using SEM a more precise picture of the body structure of Chironomidae can be revealed. It allows researchers to explain inconsistencies in the existing descriptions of species. Another advantage of the SEM method is obtaining spatial images of the body and organs of Chironomidae. However, the SEM method also has some limitations. The main problem is dirt or debris (e.g. algae, mud, secretions, mucus, bacteria, etc., which often settles on the external surface of structures, especially those which are uneven or covered with hair. The dirt should be removed after collection of chironomid material because if left in place it can become chemically fixed to various surfaces. It unnecessarily remains at the surface and final microscopic images may contain artifacts that obscure chironomid structures being investigated. In this way many details of the surface are thus unreadable. The results reported here indicate that SEM examination helps us to identify new morphological features and details that will facilitate the identification of species of Chironomidae and may help to clarify the function of various parts of the body. Fast development of electron microscope technique allows us to learn more about structure of different organisms.

  17. Orientation mapping by transmission-SEM with an on-axis detector

    International Nuclear Information System (INIS)

    Fundenberger, J.J.; Bouzy, E.; Goran, D.; Guyon, J.; Yuan, H.; Morawiec, A.

    2016-01-01

    Conventional orientation mapping in a scanning electron microscope (SEM) is a valuable technique for characterizing crystalline materials, but its application to ultrafine or nano-grain materials is limited by its spatial resolution. The resolution can be increased by collecting transmission diffraction patterns in SEM. In previous works, such patterns were collected using off-axis detectors in nearly vertical position. To avoid some drawbacks of such arrangement, a new configuration was devised in which the scintillator is located underneath the thin foil on the optical axis of the microscope, and the light is reflected towards the camera by a mirror. This simple configuration gives intense patterns even at very low probe currents, and can be potentially used for collecting maps of relatively high spatial resolution. Example maps reveal details with dimensions of about 5 nm. Because of its resolution and geometric simplicity, the proposed configuration will open new opportunities in SEM-based characterization of nanocrystalline materials. - Highlights: • New experimental configuration for SEM-based orientation mapping is presented. • The geometry of recording transmission Kikuchi patterns in SEM is simplified. • The new configuration allows for reaching relatively high spatial resolution.

  18. SEM/EDS and optical microscopy analyses of microplastics in ocean trawl and fish guts.

    Science.gov (United States)

    Wang, Zhong-Min; Wagner, Jeff; Ghosal, Sutapa; Bedi, Gagandeep; Wall, Stephen

    2017-12-15

    Microplastic particles from Atlantic and Pacific Ocean trawls, lab-fed fish guts and ocean fish guts have been characterized using optical microscopy and SEM/EDS in terms of size, morphology, and chemistry. We assessed whether these measurements could serve as a rapid screening process for subsequent identification of the likely microplastic candidates by micro-spectroscopy. Optical microscopy enabled morphological classification of the types of particles or fibers present in the sample, as well as the quantification of particle size ranges and fiber lengths. SEM/EDS analysis was used to rule out non-plastic particles and screen the prepared samples for potential microplastic, based on their element signatures and surface characteristics. Chlorinated plastics such as polyvinyl chloride (PVC) could be easily identified with SEM/EDS due to their unique elemental signatures including chlorine, as could mineral species that are falsely identified as plastics by optical microscopy. Particle morphology determined by optical microscopy and SEM suggests the fish ingested particles contained both degradation fragments from larger plastic pieces and also manufactured microplastics. SEM images of microplastic particle surfaces revealed characteristic cracks consistent with environmental exposure, as well as pigment particles consistent with manufactured materials. Most of the microplastic surfaces in the fish guts and ocean trawls were covered with biofilms, radiolarians, and crustaceans. Many of the fish stomachs contained micro-shell pieces which visually resembled microplastics. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Bioassay and Scanning Electron Microscopic Observations Reveal High Virulence of Entomopathogenic Fungus, Beauveria bassiana, on the Onion Maggot (Diptera: Anthomyiidae) Adults.

    Science.gov (United States)

    Zhang, Hui; Wu, Shengyong; Xing, Zhenlong; Wang, Xiaoqing; Lei, Zhongren

    2016-12-01

    When flies were dipped in 1 × 10 8 conidia/ml conidia suspensions and then kept in the incubator (22 ± 1 °C, 70 ± 5% RH), scanning electron microscope observations revealed that, at 2 h, the majority of adhering Beauveria bassiana conidia were attached to either the wing surface or the interstitial area between the macrochaetae on the thorax and abdomen of the onion maggot adults. Germ tubes were being produced and had oriented toward the cuticle by 18 h. Penetration of the insect cuticle had occurred by 36 h, and by 48 h, germ tubes had completely penetrated the cuticle. Fungal mycelia had emerged from the insect body and were proliferating after 72 h. The superficial area and structure of the wings and macrochaetae may facilitate the attachment of conidia and enable effective penetration. The susceptibility of adults to 12 isolates, at a concentration of 1 × 10 7 conidia/ml, was tested in laboratory experiments. Eight of the more potent strains caused in excess of 85% adult mortality 8 d post inoculation, while the median lethal time (LT 50 ) of these strains was bassiana strains are highly virulent to onion maggot adults and should be considered as potential biocontrol agents against the adult flies. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. SEM studies of the structure of the gels prepared from untreated and radiation modified potato starch

    International Nuclear Information System (INIS)

    Cieśla, Krystyna; Sartowska, Bożena; Królak, Edward

    2015-01-01

    Potato starch was irradiated with a 60 Co gamma rays using doses of 5, 10, 20 and 30 kGy. Gels containing ca. 9.1% of starch were prepared by heating the starch suspensions in the heating chamber stabilized at 100 °C. Four procedures were applied for preparation of the samples in regard to SEM studies and the ability to observe the radiation effect by SEM was assessed for each method. Differences were observed between the SEM images recorded for the non-irradiated samples prepared using all the methods, and those irradiated. Images of the non-irradiated gels indicate generally a honey-comb structure, while smooth areas but with oriented fractures has appeared after irradiation. Modification of gel structure corresponds to the applied dose. The results were related to the process of gel formation (as observed by means of the hot stage microscope) to decrease in swelling power of the irradiated starch and to decreased viscosity of the resulting gels. It can be concluded that the differences in structural properties of gels shown by SEM result probably due to the better homogenization of the gels formed after radiation induced degradation. - Highlights: • Four procedures of the preservation of starch gels for SEM studies were applied. • The ability to observe the radiation effect by SEM was assessed for each method. • Dose dependent changes in the gel structure were discovered. • It was related to decrease in the swelling power and decreased viscosity of the gels. • A hot-stage microscope was applied in order to follow the gelatinization process

  1. Description and calibration beamline SEM/Ion Chamber Current Digitizer

    International Nuclear Information System (INIS)

    Schoo, D.

    1994-05-01

    This report discusses the following on beamline SEM/ion chamber current digitizers: Module description; testing and calibration; common setup procedures; summary of fault indications and associated causes; summary of input and output connections; SEM conversion constant table; ion chamber conversion constant table; hexadecimal to decimal conversion table; and schematic diagram

  2. Structural Equations and Causal Explanations: Some Challenges for Causal SEM

    Science.gov (United States)

    Markus, Keith A.

    2010-01-01

    One common application of structural equation modeling (SEM) involves expressing and empirically investigating causal explanations. Nonetheless, several aspects of causal explanation that have an impact on behavioral science methodology remain poorly understood. It remains unclear whether applications of SEM should attempt to provide complete…

  3. The influence of environment temperature on SEM image quality

    International Nuclear Information System (INIS)

    Chen, Li; Liu, Junshan

    2015-01-01

    As the structure dimension goes down to the nano-scale, it often requires a scanning electron microscope (SEM) to provide image magnification up to 100 000  ×. However, SEM images at such a high magnification usually suffer from high resolution value and low signal-to-noise ratio, which results in low quality of the SEM image. In this paper, the quality of the SEM image is improved by optimizing the environment temperature. The experimental results indicate that at 100 000  ×, the quality of the SEM image is influenced by the environment temperature, whereas at 50 000  × it is not. At 100 000  × the best SEM image quality can be achieved from the environment temperature ranging 292 from 294 K, and the SEM image quality evaluated by the double stimulus continuous quality scale method can increase from grade 1 to grade 5. It is expected that this image quality improving method can be used in routine measurements with ordinary SEMs to get high quality images by optimizing the environment temperature. (paper)

  4. Design and Use of the Simple Event Model (SEM)

    NARCIS (Netherlands)

    van Hage, W.R.; Malaisé, V.; Segers, R.H.; Hollink, L.

    2011-01-01

    Events have become central elements in the representation of data from domains such as history, cultural heritage, multimedia and geography. The Simple Event Model (SEM) is created to model events in these various domains, without making assumptions about the domain-specific vocabularies used. SEM

  5. Canticum Novum: música sem palavras e palavras sem som no pensamento de Santo Agostinho

    OpenAIRE

    Mammì, Lorenzo

    2000-01-01

    NO De Magistro, Santo Agostinho coloca a reza e o canto numa posição similar, à margem das funções imediatamente comunicativas da linguagem. A reflexão agostiniana sobre a reza se baseia nos hábitos cristãos da leitura, da oração e da meditação silenciosas. Há sobre o canto, na prática igualmente inovadora do jubilus, melodia sem palavra destinada aos momentos mais intensos e gaudiosos da liturgia. A oração silenciosa e o jubilus são temas recorrentes da literatura patrística, mas Agostinho o...

  6. Cryo-SEM studies of latex/ceramic nanoparticle coating microstructure development.

    Science.gov (United States)

    Luo, Hui; Scriven, L E; Francis, Lorraine F

    2007-12-15

    Cryogenic scanning electron microscopy (cryo-SEM) was used to investigate microstructure development of composite coatings prepared from dispersions of antimony-doped tin oxide (ATO) nanoparticles (approximately 30 nm) or indium tin oxide (ITO) nanoparticles (approximately 40 nm) and latex particles (polydisperse, D(v): approximately 300 nm). Cryo-SEM images of ATO/latex dispersions as-frozen show small clusters of ATO and individual latex particles homogeneously distribute in a frozen water matrix. In contrast, cryo-SEM images of ITO/latex dispersions as-frozen show ITO particles adsorb onto latex particle surfaces. Electrostatic repulsion between negatively charged ATO and negatively charged latex particles stabilizes the ATO/latex dispersion, whereas in ITO/latex dispersion, positively charged ITO particles are attracted onto surfaces of negatively charged latex particles. These results are consistent with calculations of interaction potentials from past research. Cryo-SEM images of frozen and fractured coatings reveal that both ceramic nanoparticles and latex become more concentrated as drying proceeds; larger latex particles consolidate with ceramic nanoparticles in the interstitial spaces. With more drying, compaction flattens the latex-latex particle contacts and shrinks the voids between them. Thus, ceramic nanoparticles are forced to pack closely in the interstitial spaces, forming an interconnected network. Finally, latex particles partially coalesce at their flattened contacts, thereby yielding a coherent coating. The research reveals how nanoparticles segregate and interconnect among latex particles during drying.

  7. SEM evaluation of the morphological changes in hard dental tissues prepared by Er: YAG laser and rotary instruments

    Directory of Open Access Journals (Sweden)

    Tomov Georgi

    2010-09-01

    Full Text Available Effective ablation of dental hard tissues by means of the erbium:yttrium-aluminum garnet (Er: YAG laser has been reported recently, and its application to caries removal and cavity preparation has been expected. However, few studies have investigated the morphological changes in hard dental tissues after Er: YAG laser caries treatment. In the present study the morphological changes in hard dental tissues after Er: YAG laser caries ablation in vitro was compared with that of conventional mechanical treatment. Thirty extracted human teeth with caries were used. Ten tooth was treated with the Er: YAG laser, and the other was treated with a conventional steel and diamond burs. Laser treatment was performed by means of a non-contact irradiation modes with cooling water spray, with a new Er: YAG laser (LiteTouch. Conventional bur treatment was conducted by means of a low-speed micromotor and air turbine with water cooling. Scanning electron microscope (SEM observations were performed for each treatment. The Er: YAG laser ablated carious dentin effectively with minimal thermal damage to the surrounding intact dentin, and removed infected and softened carious dentin to the same degree as the burtreatment. In addition, a lower degree of vibration was noted with the Er: YAG laser treatment. The SEM examination revealed characteristic micro-irregularities of the lased dentin and enamel surfaces with potential benefits for adhesive restorations. Our results show that the Er: YAG laser is promising as a new technical modality for caries treatment

  8. HUMAN CAPSULE EPITHELIAL-CELL DEGENERATION A LM, SEM AND TEM INVESTIGATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; WORST, JGF

    1993-01-01

    The degeneration of the capsule epithelium of cataractous lenses has been studied with LM, SEM on TEM with emphases on TEM. The observed degeneration of the epithelial cells can be described as follows: The cell nucleus becomes picnotic and desintegrates as result of change of the chromatin.

  9. Characterization of Airborne Particles Collected from Car Engine Air Filters Using SEM and EDX Techniques

    Science.gov (United States)

    Heredia Rivera, Birmania; Gerardo Rodriguez, Martín

    2016-01-01

    Particulate matter accumulated on car engine air-filters (CAFs) was examined in order to investigate the potential use of these devices as efficient samplers for collecting street level air that people are exposed to. The morphology, microstructure, and chemical composition of a variety of particles were studied using scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX). The particulate matter accumulated by the CAFs was studied in two categories; the first was of removed particles by friction, and the second consisted of particles retained on the filters. Larger particles with a diameter of 74–10 µm were observed in the first category. In the second one, the detected particles had a diameter between 16 and 0.7 µm. These particles exhibited different morphologies and composition, indicating mostly a soil origin. The elemental composition revealed the presence of three groups: mineral (clay and asphalt), metallic (mainly Fe), and biological particles (vegetal and animal debris). The palynological analysis showed the presence of pollen grains associated with urban plants. These results suggest that CAFs capture a mixture of atmospheric particles, which can be analyzed in order to monitor urban air. Thus, the continuous availability of large numbers of filters and the retroactivity associated to the car routes suggest that these CAFs are very useful for studying the high traffic zones within a city. PMID:27706087

  10. Characterization of Airborne Particles Collected from Car Engine Air Filters Using SEM and EDX Techniques

    Directory of Open Access Journals (Sweden)

    Birmania Heredia Rivera

    2016-10-01

    Full Text Available Particulate matter accumulated on car engine air-filters (CAFs was examined in order to investigate the potential use of these devices as efficient samplers for collecting street level air that people are exposed to. The morphology, microstructure, and chemical composition of a variety of particles were studied using scanning electron microscopy (SEM and energy-dispersive X-ray (EDX. The particulate matter accumulated by the CAFs was studied in two categories; the first was of removed particles by friction, and the second consisted of particles retained on the filters. Larger particles with a diameter of 74–10 µm were observed in the first category. In the second one, the detected particles had a diameter between 16 and 0.7 µm. These particles exhibited different morphologies and composition, indicating mostly a soil origin. The elemental composition revealed the presence of three groups: mineral (clay and asphalt, metallic (mainly Fe, and biological particles (vegetal and animal debris. The palynological analysis showed the presence of pollen grains associated with urban plants. These results suggest that CAFs capture a mixture of atmospheric particles, which can be analyzed in order to monitor urban air. Thus, the continuous availability of large numbers of filters and the retroactivity associated to the car routes suggest that these CAFs are very useful for studying the high traffic zones within a city.

  11. SEM and TEM characterization of microstructure of stainless steel composites reinforced with TiB2

    International Nuclear Information System (INIS)

    Sulima, Iwona; Boczkal, Sonia; Jaworska, Lucyna

    2016-01-01

    Steel-8TiB 2 composites were produced by two new sintering techniques, i.e. Spark Plasma Sintering (SPS) and High Pressure-High Temperature (HP-HT) sintering. This study discusses the impact of these sintering methods on the microstructure of steel composites reinforced with TiB 2 particles. Scanning electron microscopy (SEM), wavelength dispersive spectroscopy (WDS), X-ray diffraction, electron backscatter diffraction (EBSD) and transmission electron microscopy (TEM) were used to analyze the microstructure evolution in steel matrix composites. The results of microscopic examinations revealed a close relationship between the composite microstructure and the methods and conditions of sintering. Substantial differences were observed in the grain size of materials sintered by HP-HT and SPS. It has been demonstrated that the composites sintered by HP-HT tend to form a chromium-iron-nickel phase in the steel matrix. In contrast, the microstructure of the composites sintered by SPS is characterized by the presence of complex borides and chromium-iron phase. - Highlights: •The steel-8TiB 2 composites were fabricated by Spark Plasma Sintering (SPS) and High Pressure-High Temperature (HP-HT). •Sintering techniques has an important effect on changes in the microstructure of steel-8TiB 2 composites. •New phases of different size and morphology were identified.

  12. Separating topographical and chemical analysis of nanostructure of polymer composite in low voltage SEM

    International Nuclear Information System (INIS)

    Wan, Q; Plenderleith, R A; Claeyssens, F; Rodenburg, C; Dapor, M; Rimmer, S

    2015-01-01

    The possibility of separating the topographical and chemical information in a polymer nano-composite using low-voltage SEM imaging is demonstrated, when images are acquired with a Concentric Backscattered (CBS) detector. This separation of chemical and topographical information is based on the different angular distribution of electron scattering which were calculated using a Monte Carlo simulation. The simulation based on angular restricted detection was applied to a semi-branched PNIPAM/PEGDA interpenetration network for which a linear relationship of topography SEM contrast and feature height data was observed. (paper)

  13. Ovipositor setation in oldest insects (Insecta: Archaeognatha) revealed by SEM and He-ion microscopy.

    Science.gov (United States)

    Matushkina, Nataliia A

    2017-10-01

    Archaeognatha represent the oldest living lineage of true insects (=Ectognatha), which are remarkable, among others, for plesiomorphic genital morphology and complicated mating behaviour. I used scanning electron microscopy and He-ion microscopy to examine the ovipositor morphology of seven species, in order to describe the cuticle microsculpture. The species studied are characterised by different types of the ovipositor setation pattern, which are considered an important taxonomic feature for Archaeognatha. The common and well discernible elements of ovipositor setation in Archaeognatha are: (1) non-articulated terminal seta, (2) grooved type I basiconic sensillum with apical pore, (3) multiporous type II basiconic sensillum, (4) articulated setae of different length. Coeloconica-like sensilla and campaniform sensilla demonstrate a variety of transient morphology. Results of this study provide morphological evidence of presence of olfactory receptors on the ovipositor in Archaeognatha. The possible functions of the ovipositor setation in Archaeognatha are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Exploitation of Contrasts in Low Energy SEM to Reveal True Microstructure

    Czech Academy of Sciences Publication Activity Database

    Müllerová, Ilona; Mikmeková, Šárka; Mikmeková, Eliška; Pokorná, Zuzana; Frank, Luděk

    2014-01-01

    Roč. 20, S3 (2014), s. 858-859 ISSN 1431-9276 R&D Projects: GA TA ČR TE01020118; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : scanning low energy electron microscopy * contrast * cathode lens Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.877, year: 2014

  15. Automated CD-SEM metrology for efficient TD and HVM

    Science.gov (United States)

    Starikov, Alexander; Mulapudi, Satya P.

    2008-03-01

    CD-SEM is the metrology tool of choice for patterning process development and production process control. We can make these applications more efficient by extracting more information from each CD-SEM image. This enables direct monitors of key process parameters, such as lithography dose and focus, or predicting the outcome of processing, such as etched dimensions or electrical parameters. Automating CD-SEM recipes at the early stages of process development can accelerate technology characterization, segmentation of variance and process improvements. This leverages the engineering effort, reduces development costs and helps to manage the risks inherent in new technology. Automating CD-SEM for manufacturing enables efficient operations. Novel SEM Alarm Time Indicator (SATI) makes this task manageable. SATI pulls together data mining, trend charting of the key recipe and Operations (OPS) indicators, Pareto of OPS losses and inputs for root cause analysis. This approach proved natural to our FAB personnel. After minimal initial training, we applied new methods in 65nm FLASH manufacture. This resulted in significant lasting improvements of CD-SEM recipe robustness, portability and automation, increased CD-SEM capacity and MT productivity.

  16. Comparison of multilayered nanowire imaging by SEM and Helium Ion Microscopy

    International Nuclear Information System (INIS)

    Inkson, B J; Peng, Y; Jepson, M A E; Rodenburg, C; Liu, X

    2010-01-01

    The helium ion microscope (HeIM) is capable of probe sizes smaller than SEM and, with intrinsically small ion/sample interaction volumes, may therefore potentially offer higher spatial resolution secondary electron (SE) imaging of nanostructures. Here 55 nm diameter CoPt/Pt multilayered nanowires have been imaged by HeIM, SEM and TEM. It is found that there is an increased resolution of nanowire surface topography in HeIM SE images compared to SEM, however there is a reduction of materials contrast of the alternating Pt and CoPt layers. This can be attributed to the increased contribution of surface contamination layers to the ion-induced SE signal, and carbon is also observed to grow on the nanowires under prolonged HeIM scanning.

  17. SEM-EBSP能知道些什么

    Institute of Scientific and Technical Information of China (English)

    张唯敏

    2003-01-01

    @@ 1 SEM-EBSP是什么 所谓SEM-EBSP是指采用在扫描电子显微镜(SEM)镜体中的反射电子菊池线衍射的结晶方位分析.被称为菊池图形的衍射图形可因结晶的稍许倾斜而大大地改变其位置,因此,通过解析菊池图形就能正确地知道结晶方位.

  18. Improvement of geometrical measurements from 3D-SEM reconstructions

    DEFF Research Database (Denmark)

    Carli, Lorenzo; De Chiffre, Leonardo; Horsewell, Andy

    2009-01-01

    The quantification of 3D geometry at the nanometric scale is a major metrological challenge. In this work geometrical measurements on cylindrical items obtained with a 3D-SEM were investigated. Two items were measured: a wire gauge having a 0.25 mm nominal diameter and a hypodermic needle having...... that the diameter estimation performed using the 3D-SEM leads to an overestimation of approx. 7% compared to the reference values obtained using a 1-D length measuring machine. Standard deviation of SEM measurements performed on the wire gauge is approx. 1.5 times lower than the one performed on the hypodermic...

  19. Improvement of CD-SEM mark position measurement accuracy

    Science.gov (United States)

    Kasa, Kentaro; Fukuhara, Kazuya

    2014-04-01

    CD-SEM is now attracting attention as a tool that can accurately measure positional error of device patterns. However, the measurement accuracy can get worse due to pattern asymmetry as in the case of image based overlay (IBO) and diffraction based overlay (DBO). For IBO and DBO, a way of correcting the inaccuracy arising from measurement patterns was suggested. For CD-SEM, although a way of correcting CD bias was proposed, it has not been argued how to correct the inaccuracy arising from pattern asymmetry using CD-SEM. In this study we will propose how to quantify and correct the measurement inaccuracy affected by pattern asymmetry.

  20. 3-D Analysis of Graphite Nodules in Ductile Cast Iron Using FIB-SEM

    DEFF Research Database (Denmark)

    D'Angelo, Luca; Jespersen, Freja N.; MacDonald, A. Nicole

    Ductile cast iron samples were analysed in a Focused Ion Beam Scanning Electron Microscope, FIB-SEM. The focussed ion beam was used to carefully remove layers of the graphite nodules to reveal internal structures in the nodules. The sample preparation and milling procedure for sectioning graphite...... inside the nodules, their orientation in relation to the graphite and the chemistry of the inclusions is analysed and described. Formation of the structures during solidification and subsequent cooling to room temperature is discussed....

  1. stainless steel by SEM-XRD and image analysis

    Directory of Open Access Journals (Sweden)

    Robinson Constanzo-R.

    2014-01-01

    Full Text Available El objetivo de este trabajo fue realizar un análisis cualitativ o de la distribución de un electrodepósito de cobre en el inter ior de electrodos porosos (EP de acero inoxidable y carbono grafito. Para ello, se reali zaron pruebas de electrodepositación de cobre a nivel de labora torio, con un posterior análisis de cortes de muestras de acero y grafito vía Microscopía Estereoscópica, Microscopía SEM-DRX y Análisis de Imagen, los cuales mostraron que el cobre no se deposita en forma uniforme al interior del electrodo. En el electrodo de acero, la penetra ción del depósito en el espesor fue alrededor de 50%, mientras que para el grafito a lrededor de 90%. En forma general, se observó un aumento de la cantidad de depósito hacia el extremo frente al ánodo y con sitios de difer ente crecimiento en depósito de cobre. Esto demuestra una distr ibución de corriente y potencial, función de parámetros físicos de electrodo y de la s características fisicoquímicas e hidrodinámicos del electroli to.

  2. Infrared spectra, Raman laser, XRD, DSC/TGA and SEM ...

    Indian Academy of Sciences (India)

    Administrator

    cussed and the X-ray diffraction, scanning electron microscopy (SEM) and atomic force microscope (AFM) ... acetamide as a simple organic compound at high tempera- ture has less ..... properties of selenium surface, AFM-microscopy tapping.

  3. Novel field emission SEM column with beam deceleration technology

    Energy Technology Data Exchange (ETDEWEB)

    Jiruše, Jaroslav; Havelka, Miloslav; Lopour, Filip

    2014-11-15

    A novel field-emission SEM column has been developed that features Beam Deceleration Mode, high-probe current and ultra-fast scanning. New detection system in the column is introduced to detect true secondary electron signal. The resolution power at low energy was doubled for conventional SEM optics and moderately improved for immersion optics. Application examples at low landing energies include change of contrast, imaging of non-conductive samples and thin layers. - Highlights: • A novel field-emission SEM column has been developed. • Implemented beam deceleration improves the SEM resolution at 1 keV two times. • New column maintains high analytical potential and wide field of view. • Detectors integrated in the column allow gaining true SE and BE signal separately. • Performance of the column is demonstrated on low energy applications.

  4. Role of scanning electron microscope )SEM) in metal failure analysis

    International Nuclear Information System (INIS)

    Shaiful Rizam Shamsudin; Hafizal Yazid; Mohd Harun; Siti Selina Abd Hamid; Nadira Kamarudin; Zaiton Selamat; Mohd Shariff Sattar; Muhamad Jalil

    2005-01-01

    Scanning electron microscope (SEM) is a scientific instrument that uses a beam of highly energetic electrons to examine the surface and phase distribution of specimens on a micro scale through the live imaging of secondary electrons (SE) and back-scattered electrons (BSE) images. One of the main activities of SEM Laboratory at MINT is for failure analysis on metal part and components. The capability of SEM is excellent for determining the root cause of metal failures such as ductility or brittleness, stress corrosion, fatigue and other types of failures. Most of our customers that request for failure analysis are from local petrochemical plants, manufacturers of automotive components, pipeline maintenance personnel and engineers who involved in the development of metal parts and component. This paper intends to discuss some of the technical concepts in failure analysis associated with SEM. (Author)

  5. Quantitative approach on SEM images of microstructure of clay soils

    Institute of Scientific and Technical Information of China (English)

    施斌; 李生林; M.Tolkachev

    1995-01-01

    The working principles of Videolab Image Processing System (VIPS), the examining methods of orientation of microstructural units of clay soils and analysing results on SEM images of some typical microstructures of clay soils using the VIPS are introduced.

  6. semPLS: Structural Equation Modeling Using Partial Least Squares

    Directory of Open Access Journals (Sweden)

    Armin Monecke

    2012-05-01

    Full Text Available Structural equation models (SEM are very popular in many disciplines. The partial least squares (PLS approach to SEM offers an alternative to covariance-based SEM, which is especially suited for situations when data is not normally distributed. PLS path modelling is referred to as soft-modeling-technique with minimum demands regarding mea- surement scales, sample sizes and residual distributions. The semPLS package provides the capability to estimate PLS path models within the R programming environment. Different setups for the estimation of factor scores can be used. Furthermore it contains modular methods for computation of bootstrap confidence intervals, model parameters and several quality indices. Various plot functions help to evaluate the model. The well known mobile phone dataset from marketing research is used to demonstrate the features of the package.

  7. Novel field emission SEM column with beam deceleration technology

    International Nuclear Information System (INIS)

    Jiruše, Jaroslav; Havelka, Miloslav; Lopour, Filip

    2014-01-01

    A novel field-emission SEM column has been developed that features Beam Deceleration Mode, high-probe current and ultra-fast scanning. New detection system in the column is introduced to detect true secondary electron signal. The resolution power at low energy was doubled for conventional SEM optics and moderately improved for immersion optics. Application examples at low landing energies include change of contrast, imaging of non-conductive samples and thin layers. - Highlights: • A novel field-emission SEM column has been developed. • Implemented beam deceleration improves the SEM resolution at 1 keV two times. • New column maintains high analytical potential and wide field of view. • Detectors integrated in the column allow gaining true SE and BE signal separately. • Performance of the column is demonstrated on low energy applications

  8. A new method using Scanning Electron Microscopy (SEM) for preparation of anisopterous odonates.

    Science.gov (United States)

    Del Palacio, Alejandro; Sarmiento, Patricia Laura; Javier, Muzón

    2017-10-01

    Anisopterous odonate male's secondary genitalia is a complex of several structures, among them the vesica spermalis is the most informative with important specific characters. The observation of those characters, mostly of membranous nature, is difficult in the Scanning Electron Microscope due to dehydration and metallization processes. In this contribution, we discuss a new and low cost procedure for the observation of these characters in the SEM, compatible with the most common agents used for preserving specimens. © 2017 Wiley Periodicals, Inc.

  9. DETECTION OF DELAMINATION IN A COMPOSITE PLATE BY SEM

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A numerical method of integration of Green's functi ons of strip element method (SEM) is proposed. The response of ultrasonic sourc e generated by a transducer on the surface of a multi-ply composite plate conta ining a delamination is analyzed by the use of SEM. The numerical results show that the scanning features of the ultrasonic waves may be used to identify the d elamination inside the composite plate .

  10. A methodological basis for SEM autoradiography: biosynthesis and radioligand binding

    International Nuclear Information System (INIS)

    Cheng, G.; Hodges, G.M.; Trejdosiewicz, L.K.

    1985-01-01

    A method is described for scanning electron microscope (SEM) autoradiography whereby preservation of high resolution cell surface details is retained together with degelatination of the emulsion without gross loss or redistribution of silver grains. This method should provide a convenient medium-sized marker for SEM (using secondary, backscattered electron and X-ray imaging) topographic studies of biosynthesized molecules, and of cell surface receptors and antigens, using indirect or direct labelling procedures with radio-labelled ligands. (author)

  11. SD-SEM: sparse-dense correspondence for 3D reconstruction of microscopic samples.

    Science.gov (United States)

    Baghaie, Ahmadreza; Tafti, Ahmad P; Owen, Heather A; D'Souza, Roshan M; Yu, Zeyun

    2017-06-01

    Scanning electron microscopy (SEM) imaging has been a principal component of many studies in biomedical, mechanical, and materials sciences since its emergence. Despite the high resolution of captured images, they remain two-dimensional (2D). In this work, a novel framework using sparse-dense correspondence is introduced and investigated for 3D reconstruction of stereo SEM images. SEM micrographs from microscopic samples are captured by tilting the specimen stage by a known angle. The pair of SEM micrographs is then rectified using sparse scale invariant feature transform (SIFT) features/descriptors and a contrario RANSAC for matching outlier removal to ensure a gross horizontal displacement between corresponding points. This is followed by dense correspondence estimation using dense SIFT descriptors and employing a factor graph representation of the energy minimization functional and loopy belief propagation (LBP) as means of optimization. Given the pixel-by-pixel correspondence and the tilt angle of the specimen stage during the acquisition of micrographs, depth can be recovered. Extensive tests reveal the strength of the proposed method for high-quality reconstruction of microscopic samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Automated transmission-mode scanning electron microscopy (tSEM for large volume analysis at nanoscale resolution.

    Directory of Open Access Journals (Sweden)

    Masaaki Kuwajima

    Full Text Available Transmission-mode scanning electron microscopy (tSEM on a field emission SEM platform was developed for efficient and cost-effective imaging of circuit-scale volumes from brain at nanoscale resolution. Image area was maximized while optimizing the resolution and dynamic range necessary for discriminating key subcellular structures, such as small axonal, dendritic and glial processes, synapses, smooth endoplasmic reticulum, vesicles, microtubules, polyribosomes, and endosomes which are critical for neuronal function. Individual image fields from the tSEM system were up to 4,295 µm(2 (65.54 µm per side at 2 nm pixel size, contrasting with image fields from a modern transmission electron microscope (TEM system, which were only 66.59 µm(2 (8.160 µm per side at the same pixel size. The tSEM produced outstanding images and had reduced distortion and drift relative to TEM. Automated stage and scan control in tSEM easily provided unattended serial section imaging and montaging. Lens and scan properties on both TEM and SEM platforms revealed no significant nonlinear distortions within a central field of ∼100 µm(2 and produced near-perfect image registration across serial sections using the computational elastic alignment tool in Fiji/TrakEM2 software, and reliable geometric measurements from RECONSTRUCT™ or Fiji/TrakEM2 software. Axial resolution limits the analysis of small structures contained within a section (∼45 nm. Since this new tSEM is non-destructive, objects within a section can be explored at finer axial resolution in TEM tomography with current methods. Future development of tSEM tomography promises thinner axial resolution producing nearly isotropic voxels and should provide within-section analyses of structures without changing platforms. Brain was the test system given our interest in synaptic connectivity and plasticity; however, the new tSEM system is readily applicable to other biological systems.

  13. FIB-SEM cathodoluminescence tomography: practical and theoretical considerations.

    Science.gov (United States)

    De Winter, D A M; Lebbink, M N; Wiggers De Vries, D F; Post, J A; Drury, M R

    2011-09-01

    Focused ion beam-scanning electron microscope (FIB-SEM) tomography is a powerful application in obtaining three-dimensional (3D) information. The FIB creates a cross section and subsequently removes thin slices. The SEM takes images using secondary or backscattered electrons, or maps every slice using X-rays and/or electron backscatter diffraction patterns. The objective of this study is to assess the possibilities of combining FIB-SEM tomography with cathodoluminescence (CL) imaging. The intensity of CL emission is related to variations in defect or impurity concentrations. A potential problem with FIB-SEM CL tomography is that ion milling may change the defect state of the material and the CL emission. In addition the conventional tilted sample geometry used in FIB-SEM tomography is not compatible with conventional CL detectors. Here we examine the influence of the FIB on CL emission in natural diamond and the feasibility of FIB-SEM CL tomography. A systematic investigation establishes that the ion beam influences CL emission of diamond, with a dependency on both the ion beam and electron beam acceleration voltage. CL emission in natural diamond is enhanced particularly at low ion beam and electron beam voltages. This enhancement of the CL emission can be partly explained by an increase in surface defects induced by ion milling. CL emission enhancement could be used to improve the CL image quality. To conduct FIB-SEM CL tomography, a recently developed novel specimen geometry is adopted to enable sequential ion milling and CL imaging on an untilted sample. We show that CL imaging can be manually combined with FIB-SEM tomography with a modified protocol for 3D microstructure reconstruction. In principle, automated FIB-SEM CL tomography should be feasible, provided that dedicated CL detectors are developed that allow subsequent milling and CL imaging without manual intervention, as the current CL detector needs to be manually retracted before a slice can be milled

  14. High resolution SEM imaging of gold nanoparticles in cells and tissues.

    Science.gov (United States)

    Goldstein, A; Soroka, Y; Frušić-Zlotkin, M; Popov, I; Kohen, R

    2014-12-01

    The growing demand of gold nanoparticles in medical applications increases the need for simple and efficient characterization methods of the interaction between the nanoparticles and biological systems. Due to its nanometre resolution, modern scanning electron microscopy (SEM) offers straightforward visualization of metallic nanoparticles down to a few nanometre size, almost without any special preparation step. However, visualization of biological materials in SEM requires complicated preparation procedure, which is typically finished by metal coating needed to decrease charging artefacts and quick radiation damage of biomaterials in the course of SEM imaging. The finest conductive metal coating available is usually composed of a few nanometre size clusters, which are almost identical to the metal nanoparticles employed in medical applications. Therefore, SEM monitoring of metal nanoparticles within cells and tissues is incompatible with the conventional preparation methods. In this work, we show that charging artefacts related to non-conductive biological specimen can be successfully eliminated by placing the uncoated biological sample on a conductive substrate. By growing the cells on glass pre-coated with a chromium layer, we were able to observe the uptake of 10 nm gold nanoparticles inside uncoated and unstained macrophages and keratinocytes cells. Imaging in back scattered electrons allowed observation of gold nanoparticles located inside the cells, while imaging in secondary electron gave information on gold nanoparticles located on the surface of the cells. By mounting a skin cross-section on an improved conductive holder, consisting of a silicon substrate coated with copper, we were able to observe penetration of gold nanoparticles of only 5 nm size through the skin barrier in an uncoated skin tissue. The described method offers a convenient modification in preparation procedure for biological samples to be analyzed in SEM. The method provides high

  15. Sem and phylogenetic analysis of naturalized and cultivated Epidendrum in Hawaii

    International Nuclear Information System (INIS)

    White, Ingelia P.; Porter, Brad W.; Chinen, Kimberley; Fay, Michael F.

    2013-01-01

    Naturalized populations of Epidendrum L. are found on a rocky hillside in Nuuanu-Pali and Olomana in the Koolau Mountains of Oahu, Hawaii. Scanning electron micrographs were taken to observe polymorphism among the pollinia, petals, leaves, and root tips of two Epidendrum specimens (one naturalized specimen from Nuuanu-Pali and one cultivated specimen in the greenhouse). SEM images of pollen from the naturalized Epidendrum have revealed a length of 830.31 μm and a width of 462.58 μm. Pollen length from the cultivated cultivar, by comparison, has been 724.60 μm and the width 276.17 μm. Differing cell structures on the lower surface of the petals were also observed. Polyhedral concave cells with numerous fossae (pits) were seen on the naturalized cultivar and elongated flattened cells on the cultivated one. Transections of the leaf of the naturalized specimen have been much thinner (546.33 μm) compared to the thickness of the cultivated cultivar leaf (1505.83 μm), which has contained more spongy parenchyma cells. A thinner root tip (1094.19 μm) was seen in the naturalized cultivar, as opposed to 1636.34 μm in the cultivated specimen. Relationships were compared between these two specimens along with ten other unknown Epidendrum cultivars, the plastid trnL-F gene region and conducted parsimony analysis were sequenced among the naturalized Epidendrum from Nuuanu-Pali At least six changes have separated these specimens into two clades. Shorter and longer plastid simple sequence has repeated (cpSSR) from the rps16-trnK region support separation of the five Epidendrum genotypes evaluated into these two groups, including a naturalized Epidendrum from Olomana. (author)

  16. Radioprotective Effect of Propolis on the Blood Corpuscle of a Mouse by SEM after X-irradiation on the Whole Body

    International Nuclear Information System (INIS)

    Ji, Tae Jeong

    2008-01-01

    After x-ray 5 Gy radiation on the whole body of a mouse using a linear accelerator, its leucocyte, erythrocyte, and platelet were observed by SEM. Also, after injecting propolis into the abdominal cavity, the radio-protective effect of blood corpuscles was studied. The observation of micromorphology in blood corpuscles revealed that the number of leukocyte, erythrocyte, and thrombocyte decreased in the experimental group and the lump got together in blood corpuscles after 10 and 20 days. In RBC, crack or break on the surface and poikilosperocytes were observed. In the irradiation group, the size of leucocytes was smaller than that in control group and the number of villus at the verge substantially decreased. The blood corpuscles in the propolis group, however, had the similar results to control group.

  17. Radioprotective Effect of Propolis on the Blood Corpuscle of a Mouse by SEM after X-irradiation on the Whole Body

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Tae Jeong [Dept. of Radiological Science, Kaya University, Kimhae (Korea, Republic of)

    2008-03-15

    After x-ray 5 Gy radiation on the whole body of a mouse using a linear accelerator, its leucocyte, erythrocyte, and platelet were observed by SEM. Also, after injecting propolis into the abdominal cavity, the radio-protective effect of blood corpuscles was studied. The observation of micromorphology in blood corpuscles revealed that the number of leukocyte, erythrocyte, and thrombocyte decreased in the experimental group and the lump got together in blood corpuscles after 10 and 20 days. In RBC, crack or break on the surface and poikilosperocytes were observed. In the irradiation group, the size of leucocytes was smaller than that in control group and the number of villus at the verge substantially decreased. The blood corpuscles in the propolis group, however, had the similar results to control group.

  18. Sparsity-Based Super Resolution for SEM Images.

    Science.gov (United States)

    Tsiper, Shahar; Dicker, Or; Kaizerman, Idan; Zohar, Zeev; Segev, Mordechai; Eldar, Yonina C

    2017-09-13

    The scanning electron microscope (SEM) is an electron microscope that produces an image of a sample by scanning it with a focused beam of electrons. The electrons interact with the atoms in the sample, which emit secondary electrons that contain information about the surface topography and composition. The sample is scanned by the electron beam point by point, until an image of the surface is formed. Since its invention in 1942, the capabilities of SEMs have become paramount in the discovery and understanding of the nanometer world, and today it is extensively used for both research and in industry. In principle, SEMs can achieve resolution better than one nanometer. However, for many applications, working at subnanometer resolution implies an exceedingly large number of scanning points. For exactly this reason, the SEM diagnostics of microelectronic chips is performed either at high resolution (HR) over a small area or at low resolution (LR) while capturing a larger portion of the chip. Here, we employ sparse coding and dictionary learning to algorithmically enhance low-resolution SEM images of microelectronic chips-up to the level of the HR images acquired by slow SEM scans, while considerably reducing the noise. Our methodology consists of two steps: an offline stage of learning a joint dictionary from a sequence of LR and HR images of the same region in the chip, followed by a fast-online super-resolution step where the resolution of a new LR image is enhanced. We provide several examples with typical chips used in the microelectronics industry, as well as a statistical study on arbitrary images with characteristic structural features. Conceptually, our method works well when the images have similar characteristics, as microelectronics chips do. This work demonstrates that employing sparsity concepts can greatly improve the performance of SEM, thereby considerably increasing the scanning throughput without compromising on analysis quality and resolution.

  19. Reversal of infall in SgrB2(M) revealed by Herschel/HIFI observations of HCN lines at THz frequencies

    NARCIS (Netherlands)

    Rolffs, R.; Schilke, P.; Comito, C.; Bergin, E. A.; van der Tak, F. F. S.; Lis, D. C.; Qin, S.-L.; Menten, K. M.; Guesten, R.; Bell, T. A.; Blake, G.A.; Caux, E.; Ceccarelli, C.; Cernicharo, J.; Crockett, N. R.; Daniel, F.; Dubernet, M. -L.; Emprechtinger, M.; Encrenaz, P.; Gerin, M.; Giesen, T. F.; Goicoechea, J. R.; Goldsmith, P. F.; Gupta, H.; Herbst, E.; Joblin, C.; Johnstone, D.; Langer, W. D.; Latter, W. D.; Lord, S. D.; Maret, S.; Martin, P. G.; Melnick, G. J.; Morris, P.; Mueller, H. S. P.; Murphy, J. A.; Ossenkopf, V.; Pearson, J. C.; Perault, M.; Phillips, T. G.; Plume, R.; Schlemmer, S.; Stutzki, J.; Trappe, N.; Vastel, C.; Wang, S.; Yorke, H. W.; Yu, S.; Zmuidzinas, J.; Diez-Gonzalez, M. C.; Bachiller, R.; Martin-Pintado, J.; Baechtold, W.; Olberg, M.; Nordh, L. H.; Gill, J. J.; Chattopadhyay, G.

    2010-01-01

    Aims. To investigate the accretion and feedback processes in massive star formation, we analyze the shapes of emission lines from hot molecular cores, whose asymmetries trace infall and expansion motions. Methods. The high-mass star forming region SgrB2(M) was observed with Herschel/HIFI (HEXOS key

  20. The First Simultaneous Microlensing Observations by Two Space Telescopes: Spitzer and Swift Reveal a Brown Dwarf in Event OGLE-2015-BLG-1319

    Science.gov (United States)

    Shvartzvald, Y.; Li, Z.; Udalski, A.; Gould, A.; Sumi, T.; Street, R. A.; Calchi Novati, S.; Hundertmark, M.; Bozza, V.; Beichman, C.; hide

    2016-01-01

    Simultaneous observations of microlensing events from multiple locations allow for the breaking of degeneracies between the physical properties of the lensing system, specifically by exploring different regions of the lens plane and by directly measuring the "microlens parallax". We report the discovery of a 30-65M J brown dwarf orbiting a K dwarf in the microlensing event OGLE-2015-BLG-1319. The system is located at a distance of approximately 5 kpc toward the Galactic Bulge. The event was observed by several ground-based groups as well as by Spitzer and Swift, allowing a measurement of the physical properties. However, the event is still subject to an eight-fold degeneracy, in particular the well-known close-wide degeneracy, and thus the projected separation between the two lens components is either approximately 0.25 au or approximately 45 au. This is the first microlensing event observed by Swift, with the UVOT camera. We study the region of microlensing parameter space to which Swift is sensitive, finding that though Swift could not measure the microlens parallax with respect to ground-based observations for this event, it can be important for other events. Specifically, it is important for detecting nearby brown dwarfs and free-floating planets in high magnification events.

  1. Cytomorphology review of 100 newly diagnosed lower-risk MDS patients in the European LeukemiaNet MDS (EUMDS) registry reveals a high inter-observer concordance

    NARCIS (Netherlands)

    Swart, L. de; Smith, A.; MacKenzie, M.; Symeonidis, A.; Neukirchen, J.; Mikulenkova, D.; Vallespi, T.; Zini, G.; Paszkowska-Kowalewska, M.; Kruger, A.; Saft, L.; Fenaux, P.; Bowen, D.; Hellstrom-Lindberg, E.; Cermak, J.; Stauder, R.; Tatic, A.; Holm, M.S.; Malcovati, L.; Madry, K.; Droste, J.A.; Blijlevens, N.M.; Witte, T.J. de; Germing, U.

    2017-01-01

    The European LeukemiaNet MDS (EUMDS) registry is collecting data of myelodysplastic syndrome (MDS) patients belonging to the IPSS low or intermediate-1 category, newly diagnosed by local cytologists. The diagnosis of MDS can be challenging, and some data report inter-observer variability with regard

  2. 3D imaging of cells and tissues by focused ion beam/scanning electron microscopy (FIB/SEM).

    Science.gov (United States)

    Drobne, Damjana

    2013-01-01

    Integration of a scanning electron microscope (SEM) and focused ion beam (FIB) technology into a single FIB/SEM system permits use of the FIB as a nano-scalpel to reveal site-specific subsurface microstructures which can be examined in great detail by SEM. The FIB/SEM technology is widely used in the semiconductor industry and material sciences, and recently its use in the life sciences has been initiated. Samples for FIB/SEM investigation can be either embedded in a plastic matrix, the traditional means of preparation of transmission electron microscopy (TEM) specimens, or simply dried as in samples prepared for SEM imaging. Currently, FIB/SEM is used in the life sciences for (a) preparation by the lift-out technique of lamella for TEM analysis, (b) tomography of samples embedded in a matrix, and (c) in situ site-specific FIB milling and SEM imaging using a wide range of magnifications. Site-specific milling and imaging has attracted wide interest as a technique in structural research of single eukaryotic and prokaryotic cells, small animals, and different animal tissue, but it still remains to be explored more thoroughly. In the past, preparation of samples for site-specific milling and imaging by FIB/SEM has typically adopted the embedding techniques used for TEM samples, and which have been very well described in the literature. Sample preparation protocols for the use of dried samples in FIB/SEM have been less well investigated. The aim of this chapter is to encourage application of FIB/SEM on dried biological samples. A detailed description of conventional dried sample preparation and FIB/SEM investigation of dried biological samples is presented. The important steps are described and illustrated, and direct comparison between embedded and dried samples of same tissues is provided. The ability to discover links between gross morphology of the tissue or organ, surface characteristics of any selected region, and intracellular structural details on the nanometer

  3. SEM facility for examination of reactive and radioactive materials

    International Nuclear Information System (INIS)

    Downs, G.L.; Tucker, P.A.

    1977-01-01

    A scanning electron microscope (SEM) facility for the examination of tritium-containing materials is operational at Mound Laboratory. The SEM is installed with the sample chamber incorporated as an integral part of an inert gas glovebox facility to enable easy handling of radioactive and pyrophoric materials. A standard SEM (ETEC Model B-1) was modified to meet dimensional, operational, and safety-related requirements. a glovebox was designed and fabricated which permitted access with the gloves to all parts of the SEM sample chamber to facilitate director and accessory replacement and repairs. A separate console combining the electron optical column and specimen chamber was interfaced to the glovebox by a custom-made, neoprene bellows so that the vibrations normally associated with the blowers and pumps were damped. Photomicrographs of tritiated pyrophoric materials show the usefulness of this facility. Some of the difficulties involved in the investigation of these materials are also discussed. The SEM is also equipped with an energy dispersive x-ray detector (ORTEC) and a Secondary Ion Mass Spectrometer (3M) attachments. This latter attachment allows analysis of secondary ions with masses ranging from 1-300 amu. (Auth.)

  4. Recent advances in 3D SEM surface reconstruction.

    Science.gov (United States)

    Tafti, Ahmad P; Kirkpatrick, Andrew B; Alavi, Zahrasadat; Owen, Heather A; Yu, Zeyun

    2015-11-01

    The scanning electron microscope (SEM), as one of the most commonly used instruments in biology and material sciences, employs electrons instead of light to determine the surface properties of specimens. However, the SEM micrographs still remain 2D images. To effectively measure and visualize the surface attributes, we need to restore the 3D shape model from the SEM images. 3D surface reconstruction is a longstanding topic in microscopy vision as it offers quantitative and visual information for a variety of applications consisting medicine, pharmacology, chemistry, and mechanics. In this paper, we attempt to explain the expanding body of the work in this area, including a discussion of recent techniques and algorithms. With the present work, we also enhance the reliability, accuracy, and speed of 3D SEM surface reconstruction by designing and developing an optimized multi-view framework. We then consider several real-world experiments as well as synthetic data to examine the qualitative and quantitative attributes of our proposed framework. Furthermore, we present a taxonomy of 3D SEM surface reconstruction approaches and address several challenging issues as part of our future work. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. A methodology for extending domain coverage in SemRep.

    Science.gov (United States)

    Rosemblat, Graciela; Shin, Dongwook; Kilicoglu, Halil; Sneiderman, Charles; Rindflesch, Thomas C

    2013-12-01

    We describe a domain-independent methodology to extend SemRep coverage beyond the biomedical domain. SemRep, a natural language processing application originally designed for biomedical texts, uses the knowledge sources provided by the Unified Medical Language System (UMLS©). Ontological and terminological extensions to the system are needed in order to support other areas of knowledge. We extended SemRep's application by developing a semantic representation of a previously unsupported domain. This was achieved by adapting well-known ontology engineering phases and integrating them with the UMLS knowledge sources on which SemRep crucially depends. While the process to extend SemRep coverage has been successfully applied in earlier projects, this paper presents in detail the step-wise approach we followed and the mechanisms implemented. A case study in the field of medical informatics illustrates how the ontology engineering phases have been adapted for optimal integration with the UMLS. We provide qualitative and quantitative results, which indicate the validity and usefulness of our methodology. Published by Elsevier Inc.

  6. Recent improvement of a FIB-SEM serial-sectioning method for precise 3D image reconstruction - application of the orthogonally-arranged FIB-SEM.

    Science.gov (United States)

    Hara, Toru

    2014-11-01

    IntroductionWe installed the first "orthogonally-arranged" FIB-SEM in 2011. The most characteristic point of this instrument is that the FIB and SEM columns are perpendicularly mounted; this is specially designed to obtain a serial-sectioning dataset more accurately and precisely with higher contrast and higher spatial resolution compare to other current FIB-SEMs [1]. Since the installation in 2011, we have developed the hardware and methodology of the serial-sectioning based on this orthogonal FIB-SEM. In order to develop this technique, we have widely opened this instrument to every researcher of all fields. In the presentation, I would like to introduce some of application results that are obtained by users of this instrument. The characteristic points of the orthogonal systemFigure 1 shows a difference between the standard and the orthogonal FIB-SEM systems: In the standard system, shown in Fig.1(a), optical axes of a FIB and a SEM crosses around 60deg., while in the orthogonal system (Fig.1(b)), they are perpendicular to each other. The standard arrangement (a) is certainly suitable for TEM lamellae preparation etc. because the FIB and the SEM can see the same position simultaneously. However, for a serial-sectioning, it is not to say the best arrangement. One of the reasons is that the sliced plane by the FIB is not perpendicular to the electron beam so that the background contrast is not uniform and observed plane is distorted. On the other hand, in case of the orthogonally-arranged system,(b), these problems are resolved. In addition, spatial resolution can keep high enough even in a low accelerating voltage (e.g. 500V) because a working distance is set very small, 2mm. From these special design, we can obtain the serial-sectioning dataset from rather wide area (∼100um) with high spatial resolution (Max. 2×2×2nm). As this system has many kinds of detectors: SE, ET, Backscatter Electron(Energy-selective), EDS, EBSD, STEM(BF&ADF), with Ar+ ion-gun and a

  7. AxiSEM3D: broadband seismic wavefields in 3-D aspherical Earth models

    Science.gov (United States)

    Leng, K.; Nissen-Meyer, T.; Zad, K. H.; van Driel, M.; Al-Attar, D.

    2017-12-01

    Seismology is the primary tool for data-informed inference of Earth structure and dynamics. Simulating seismic wave propagation at a global scale is fundamental to seismology, but remains as one of most challenging problems in scientific computing, because of both the multiscale nature of Earth's interior and the observable frequency band of seismic data. We present a novel numerical method to simulate global seismic wave propagation in realistic 3-D Earth models. Our method, named AxiSEM3D, is a hybrid of spectral element method and pseudospectral method. It reduces the azimuthal dimension of wavefields by means of a global Fourier series parameterization, of which the number of terms can be locally adapted to the inherent azimuthal smoothness of the wavefields. AxiSEM3D allows not only for material heterogeneities, such as velocity, density, anisotropy and attenuation, but also for finite undulations on radial discontinuities, both solid-solid and solid-fluid, and thereby a variety of aspherical Earth features such as ellipticity, topography, variable crustal thickness, and core-mantle boundary topography. Such interface undulations are equivalently interpreted as material perturbations of the contiguous media, based on the "particle relabelling transformation". Efficiency comparisons show that AxiSEM3D can be 1 to 3 orders of magnitude faster than conventional 3-D methods, with the speedup increasing with simulation frequency and decreasing with model complexity, but for all realistic structures the speedup remains at least one order of magnitude. The observable frequency range of global seismic data (up to 1 Hz) has been covered for wavefield modelling upon a 3-D Earth model with reasonable computing resources. We show an application of surface wave modelling within a state-of-the-art global crustal model (Crust1.0), with the synthetics compared to real data. The high-performance C++ code is released at github.com/AxiSEM3D/AxiSEM3D.

  8. The mechanism of mid-latitude Pi2 waves in the upper ionosphere as revealed by combined Doppler and magnetometer observations

    Directory of Open Access Journals (Sweden)

    V. A. Pilipenko

    2013-04-01

    Full Text Available The interpretation of simultaneous ionospheric Doppler sounding and ground magnetometer observations of low-latitude Pi2 waves is revised. We compare the theoretical estimates of the ionospheric Doppler velocity for the same amplitude of the ground magnetic disturbances produced by a large-scale compressional mode and an Alfvén mode. The plasma vertical displacement caused by the wave electric field is shown to be the dominating effect. Taking into account the correction of the previous paper, the observations of low-latitude Pi2 in the F layer ionosphere by Doppler sounding and SuperDARN (Super Dual Auroral Radar Network radars give consistent results. We suggest that the Doppler response to Pi2 waves is produced by the Alfvén wave component, but not the fast-mode component, whereas the ground magnetic signal is composed from both Alfvén and fast magnetosonic modes.

  9. SemGroup acquisition of central Alberta midstream : case study

    International Nuclear Information System (INIS)

    Purcell, T.

    2005-01-01

    A case study of SemGroup's acquisition of Central Alberta Midstream was presented. SemCAMS specializes in providing more efficient supply, storage, and distribution assets and services. Seminole Canada Gas is a leading independent natural gas marketing and energy asset management company that currently markets 369 MMbtu per day. The company purchases natural gas in western Canada for fee-based marketing services while also managing firm transportation contracts and providing gas storage for third party customers. SemCAMS owns the largest sour gas processor in Alberta as well as 3 sour gas processing plants, 600 miles of gathering pipeline, and a sweet gas processing plant. the company is also planning increased drilling and production activities and is now pursuing aggressive land acquisition policies. Over 25,000 square miles of land have been acquired. It was concluded that midstream companies should be customer-focused, provide reliability and guarantees, infrastructure investment and optimization. tabs., figs

  10. Critical factors in SEM 3D stereo microscopy

    DEFF Research Database (Denmark)

    Marinello, F.; Bariano, P.; Savio, E.

    2008-01-01

    This work addresses dimensional measurements performed with the scanning electron microscope (SEM) using 3D reconstruction of surface topography through stereo-photogrammetry. The paper presents both theoretical and experimental investigations, on the effects of instrumental variables and measure......This work addresses dimensional measurements performed with the scanning electron microscope (SEM) using 3D reconstruction of surface topography through stereo-photogrammetry. The paper presents both theoretical and experimental investigations, on the effects of instrumental variables...... factors are recognized: the first one is related to the measurement operation and the instrument set-up; the second concerns the quality of scanned images and represents the major criticality in the application of SEMs for 3D characterizations....

  11. Annual International DIC Society Conference and SEM Fall Conference

    CERN Document Server

    Reu, Phillip

    2017-01-01

    This collection represents a single volume of technical papers presented at the Annual International DIC Society Conference and SEM Fall Conference organized by the Society for Experimental Mechanics and Sandia National Laboratories and held in Philadelphia, PA, November 7-10, 2016. The volume presents early findings from experimental, standards development and various other investigations concerning digital image correlation - an important area within Experimental Mechanics. The area of Digital Image Correlation has been an integral track within the SEM Annual Conference spearheaded by Professor Michael Sutton from the University of South Carolina. In 2016, the SEM and Sandia joined their collaborative strengths to launch a standing fall meeting focusing specifically on developments in the area of Digital Image Correlation. The contributed papers within this volume span numerous technical aspects of DIC including standards development for the industry. .

  12. SemVisM: semantic visualizer for medical image

    Science.gov (United States)

    Landaeta, Luis; La Cruz, Alexandra; Baranya, Alexander; Vidal, María.-Esther

    2015-01-01

    SemVisM is a toolbox that combines medical informatics and computer graphics tools for reducing the semantic gap between low-level features and high-level semantic concepts/terms in the images. This paper presents a novel strategy for visualizing medical data annotated semantically, combining rendering techniques, and segmentation algorithms. SemVisM comprises two main components: i) AMORE (A Modest vOlume REgister) to handle input data (RAW, DAT or DICOM) and to initially annotate the images using terms defined on medical ontologies (e.g., MesH, FMA or RadLex), and ii) VOLPROB (VOlume PRObability Builder) for generating the annotated volumetric data containing the classified voxels that belong to a particular tissue. SemVisM is built on top of the semantic visualizer ANISE.1

  13. SEM based overlay measurement between resist and buried patterns

    Science.gov (United States)

    Inoue, Osamu; Okagawa, Yutaka; Hasumi, Kazuhisa; Shao, Chuanyu; Leray, Philippe; Lorusso, Gian; Baudemprez, Bart

    2016-03-01

    With the continuous shrink in pattern size and increased density, overlay control has become one of the most critical issues in semiconductor manufacturing. Recently, SEM based overlay of AEI (After Etch Inspection) wafer has been used for reference and optimization of optical overlay (both Image Based Overlay (IBO) and Diffraction Based Overlay (DBO)). Overlay measurement at AEI stage contributes monitor and forecast the yield after formation by etch and calibrate optical measurement tools. however those overlay value seems difficult directly for feedback to a scanner. Therefore, there is a clear need to have SEM based overlay measurements of ADI (After Develop Inspection) wafers in order to serve as reference for optical overlay and make necessary corrections before wafers go to etch. Furthermore, to make the corrections as accurate as possible, actual device like feature dimensions need to be measured post ADI. This device size measurement is very unique feature of CDSEM , which can be measured with smaller area. This is currently possible only with the CD-SEM. This device size measurement is very unique feature of CD-SEM , which can be measured with smaller area. In this study, we assess SEM based overlay measurement of ADI and AEI wafer by using a sample from an N10 process flow. First, we demonstrate SEM based overlay performance at AEI by using dual damascene process for Via 0 (V0) and metal 1 (M1) layer. We also discuss the overlay measurements between litho-etch-litho stages of a triple patterned M1 layer and double pattern V0. Second, to illustrate the complexities in image acquisition and measurement we will measure overlay between M1B resist and buried M1A-Hard mask trench. Finally, we will show how high accelerating voltage can detect buried pattern information by BSE (Back Scattering Electron). In this paper we discuss the merits of this method versus standard optical metrology based corrections.

  14. The application of SEM in analyzing the damage to the petroleum reservoirs caused by drilling fluids

    International Nuclear Information System (INIS)

    Abdul Razak Ismail

    1996-01-01

    An experimental study has been conducted to analyze the damage to the potential oil and gas reservoirs due to the invasion of drilling fluid during drilling operation. Two types of rock samples representing low and high permeability were used to stimulate the petroleum reservoirs. Sea water based drilling fluids were used in this study. Detail observations to the rock samples were analyzed using scanning electron microscope (SEM). The results of both permeability restoration and SEM observation showed that severe permeability impairments were obtained for high permeability rock. These results indicate that the relative size of the barite particles and the pore size distribution and characteristics of the formation play an important role in determining the damage caused by the drilling fluids

  15. Urban Heat Islands of the World's Major Cities Revealed at Multiple Scales Using Both Station Observations and Complementary Remotely Sensed Data Products

    Science.gov (United States)

    Nguyen, L. H.; Krehbiel, C.; Henebry, G. M.

    2016-12-01

    Urban heat islands (UHIs) have long been studied using both ground-based observations of air temperature and remotely sensed data. In the rapidly urbanizing world, cross-comparison between various datasets will allow us to characterize and model UHI effects more generally. Here we analyze UHIs of the world's major cities using station observations from the Global Historical Climate Network (GHCN), surface air temperatures derived from Advanced Microwave Scanning Radiometers (AMSRs), and land surface temperatures (LST) estimated from Moderate-resolution Imaging Spectroradiometer (MODIS). We compute the two measurements of thermal time (accumulated diurnal degree-days or ADDD and nocturnal degree-days or ANDD) and the normalized difference accumulated thermal time index (NDATTI) to characterize urban and rural thermal differences and day-night dynamics over multiple growing seasons. Our preliminary results for 27 major cities and 83 urban-rural groupings in the USA and Canada indicate that daytime urban thermal accumulations from the passive microwave data (AMSRs) were generally lower than in adjacent rural areas, with only 18% of urban-rural groupings showing higher thermal accumulations in cities. In contrast, station observations and MODIS LST showed consistently higher ADDD in cities (82% and 93% for GHCN and MODIS data respectively). UHIs are more pronounced at night, with 55% (AMSR), 93% (GHCN) and 100% (MODIS) of urban-rural groupings showing higher ANDD in cities. Humidity appears to be a common factor driving the day-night thermal dynamics throughout all three datasets (Figure 1). Normalized day-night differences in thermal time metrics were consistently lower (>90% of urban-rural groupings) in urban than rural areas for both air temperature datasets (GHCN and AMSRs). With MODIS LST, only 70% of urban-rural groupings show lower NDATTI in cities. We will present results for the rest of the globe.

  16. Protons, ions, electrons and the future of the SEM

    International Nuclear Information System (INIS)

    Joy, D C

    2010-01-01

    The Scanning Electron Microscope (SEM) is the most widely used high performance microscope in all fields of science but it is now reaching the theoretical limits of its performance. While advances in sources, optics, and detectors, can result in some improvement in performance the ultimate resolution is limited by fundamental physical constraints. One potential alternative is a scanning microscope utilizing light ions such as H+ and He+ . Such an instrument shares all of the benefits of the conventional SEM but is free from the constraints encountered when using electrons and could significantly extend the scope and success of scanning microscopy.

  17. What Determines Lean Manufacturing Implementation? A CB-SEM Model

    Directory of Open Access Journals (Sweden)

    Tan Ching Ng

    2018-02-01

    Full Text Available This research aims to ascertain the determinants of effective Lean Manufacturing (LM. In this research, Covariance-based Structural Equation Modeling (CB-SEM analysis will be used in order to analyze the determinants. Through CB-SEM analysis, the significant key determinants can be determined and the direct relationships among determinants can be analyzed. Thus, the findings of this research can act as guidelines for achievement of LM effectiveness, not only providing necessary steps for successful implementation of lean, but also helping lean companies to achieve higher level of lean cost and time savings.

  18. A Data-Driven Approach to SEM Development at a Two-Year College

    Science.gov (United States)

    Pirius, Landon K.

    2014-01-01

    This article explores implementation of strategic enrollment management (SEM) at a two-year college and why SEM is critical to the long-term viability of an institution. This article also outlines the five initial steps needed to implement SEM, including identifying SEM leadership, building a SEM committee, developing a common understanding of…

  19. Seasonal deformation and active landslide thickness revealed by spaceborne InSAR observations: a case study of Crescent lake landslide, WA

    Science.gov (United States)

    Hu, X.; Lu, Z.; Pierson, T. C.; Kramer, R.

    2017-12-01

    Understanding the precipitation triggering mechanism and quantifying the creeping landslide thickness are important to conduct early warnings and estimate potential failure volume and runout extent. However, it is problematic to use traditional geodetic methods to identify the active landslide boundaries and capture the transient mobility over hilly and vegetated landslide landscape. Here we present a novel InSAR processing strategy to characterize the spatial distribution and temporal behavior of the landslide movement in response to precipitation over Crescent lake landslide, WA using spaceborne SAR data of ALOS-1 PALSAR-1, ALOS-2 PALSAR-2 and Sentinel-1A. Time-series measurements reveal the seasonal deformation of landslide lobe, showing a much larger magnitude compared to the motion at lower elevated terrain expressed by an off-slide GPS station, suggesting an amplified hydrological loading effect associated with thick unconsolidated zone. Thanks to the high temporal resolution of Sentinel-1A and on-slide GPS data, we capture the progressive incipient motions in the wet season, characterized by the elastic slope-normal contraction due to loading during antecedent rainfall, followed by downslope slip and lateral propagation in less than one-month intense precipitation, because the elevated pore pressure and the reduced friction at the basal instigate the shear motion. The proposed threshold precipitation concept, in terms of the intensity and duration, can be an integral part of the landslide warning system. The active thickness can be inverted using three-dimensional (3D) displacement map based on the principle of mass conservation. We extract quasi-3D displacements using two independent (ascending and descending) InSAR measurements assuming that the targets move exclusively along the aspect direction on the slope-parallel plane. This routine of the extraction of quasi-3D displacement and the inversion of active lobe thickness can be utilized in the study of

  20. GEOMETRIC AND KINEMATIC STRUCTURE OF THE OUTFLOW/ENVELOPE SYSTEM OF L1527 REVEALED BY SUBARCSECOND-RESOLUTION OBSERVATION OF CS

    Energy Technology Data Exchange (ETDEWEB)

    Oya, Yoko; López-Sepulcre, Ana; Watanabe, Yoshimasa; Yamamoto, Satoshi [Department of Physics, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Sakai, Nami [The Institute of Physical and Chemical Research (RIKEN), Wako, Saitama 351-0198 (Japan); Lefloch, Bertrand; Ceccarelli, Cecilia, E-mail: oya@taurus.phys.s.u-tokyo.ac.jp [Universite Grenoble Alpes, IPAG, F-38000 Grenoble (France)

    2015-10-10

    Subarcsecond-resolution images of the rotational line emissions of CS and c-C{sub 3}H{sub 2} obtained toward the low-mass protostar IRAS 04368+2557 in L1527 with the Atacama Large Millimeter/submillimeter Array are investigated to constrain the orientation of the outflow/envelope system. The distribution of CS consists of an envelope component extending from north to south and a faint butterfly shaped outflow component. The kinematic structure of the envelope is well reproduced by a simple ballistic model of an infalling rotating envelope. Although the envelope has a nearly edge-on configuration, we find that the western side of the envelope faces the observer. This configuration is opposite to the direction of the large-scale (∼10{sup 4} AU) outflow suggested previously from the {sup 12}CO (J = 3–2) observation, and to the morphology of infrared reflection near the protostar (∼200 AU). The latter discrepancy could originate from high extinction by the outflow cavity of the western side, or may indicate that the outflow axis is not parallel to the rotation axis of the envelope. Position–velocity diagrams show the accelerated outflow cavity wall, and its kinematic structure in the 2000 AU scale is explained by a standard parabolic model with the inclination angle derived from the analysis of the envelope. The different orientation of the outflow between the small and large scale implies a possibility of precession of the outflow axis. The shape and the velocity of the outflow in the vicinity of the protostar are compared with those of other protostars.

  1. Cytomorphology review of 100 newly diagnosed lower-risk MDS patients in the European LeukemiaNet MDS (EUMDS) registry reveals a high inter-observer concordance.

    Science.gov (United States)

    de Swart, Louise; Smith, Alex; MacKenzie, Marius; Symeonidis, Argiris; Neukirchen, Judith; Mikulenková, Dana; Vallespí, Teresa; Zini, Gina; Paszkowska-Kowalewska, Malgorzata; Kruger, Anton; Saft, Leonie; Fenaux, Pierre; Bowen, David; Hellström-Lindberg, Eva; Čermák, Jaroslav; Stauder, Reinhard; Tatic, Aurelia; Holm, Mette Skov; Malcovati, Luca; Mądry, Krzysztof; Droste, Jackie; Blijlevens, Nicole; de Witte, Theo; Germing, Ulrich

    2017-07-01

    The European LeukemiaNet MDS (EUMDS) registry is collecting data of myelodysplastic syndrome (MDS) patients belonging to the IPSS low or intermediate-1 category, newly diagnosed by local cytologists. The diagnosis of MDS can be challenging, and some data report inter-observer variability with regard to the assessment of the MDS subtype. In order to ensure that correct diagnoses were made by the participating centres, blood and bone marrow slides of 10% of the first 1000 patients were reviewed by an 11-person panel of cytomorphologists. All slides were rated by at least 3 panel members (median 8 panel members; range 3-9). Marrow slides from 98 out of 105 patients were of good quality and therefore could be rated properly according to the WHO 2001 classification, including assessment of dysplastic lineages. The agreement between the reviewers whether the diagnosis was MDS or non-MDS was strong with an intra-class correlation coefficient (ICC) of 0.85. Six cases were detected not to fit the entry criteria of the registry, because they were diagnosed uniformly as CMML or AML by the panel members. The agreement by WHO 2001 classification was strong as well (ICC = 0.83). The concordance of the assessment of dysplastic lineages was substantial for megakaryopoiesis and myelopoiesis and moderate for erythropoiesis. Our data show that in general, the inter-observer agreement was high and a very low percentage of misdiagnosed cases had been entered into the EUMDS registry. Further studies including histomorphology are warranted.

  2. Cuticle scale measurement of animal fibers by SEM and AFM

    CSIR Research Space (South Africa)

    Notayi, M

    2013-12-01

    Full Text Available -1 51st Microscopy Society of Southern Africa (MSSA) Conference, Farm Inn, Pretoria, 3-6 December 2013 Cuticle scale measurement of animal fibers by SEM and AFM Notayi M, Engelbrechts JAA, Lee ME, Goosen WE, Hunter L and Botha AF Abstract...

  3. Estudo comparativo entre histerectomia abdominal e vaginal sem prolapso uterino

    OpenAIRE

    Lisboa, Vânio Cardoso

    2002-01-01

    Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Ciências Médicas. Objetivo: Comparar a histerectomia abdominal e vaginal sem prolapso uterino.

  4. SEM based CARMA time series modeling for arbitrary N

    NARCIS (Netherlands)

    Oud, J.H.L.; Völkle, M.C.; Driver, C.C.

    2018-01-01

    This article explains in detail the state space specification and estimation of first and higher-order autoregressive moving-average models in continuous time (CARMA) in an extended structural equation modeling (SEM) context for N = 1 as well as N > 1. To illustrate the approach, simulations will be

  5. DSS1/Sem1, a multifunctional and intrinsically disordered protein

    DEFF Research Database (Denmark)

    Kragelund, Birthe Brandt; Schenstrøm, Signe Marie; Rebula, Caio A.

    2016-01-01

    DSS1/Sem1 is a versatile intrinsically disordered protein. Besides being a bona fide subunit of the 26S proteasome, DSS1 associates with other protein complexes, including BRCA2-RPA, involved in homologous recombination; the Csn12-Thp3 complex, involved in RNA splicing; the integrator, involved...

  6. The principle of electron microscopy; SEM and TEM

    International Nuclear Information System (INIS)

    Fauzi, S.H.

    1992-01-01

    The article reviews the principle of electron microscopy which is used in scanning electron microscope (SEM) and transmission electron microscope (TEM). These instruments are important for the examination and analysis of the microstructural properties of solid objects. Relevance physical concept lies behind the devices are given. The main components of each device are also discussed

  7. Continuous time modeling of panel data by means of SEM

    NARCIS (Netherlands)

    Oud, J.H.L.; Delsing, M.J.M.H.; Montfort, C.A.G.M.; Oud, J.H.L.; Satorra, A.

    2010-01-01

    After a brief history of continuous time modeling and its implementation in panel analysis by means of structural equation modeling (SEM), the problems of discrete time modeling are discussed in detail. This is done by means of the popular cross-lagged panel design. Next, the exact discrete model

  8. Processing a Biological Tissue from Cryo-SEM to Replica

    Czech Academy of Sciences Publication Activity Database

    Vaškovicová, Naděžda; Hrubanová, Kamila; Krzyžánek, Vladislav

    2016-01-01

    Roč. 22, S3 (2016), s. 236-237 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : Cryo-SEM * ACE600 Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.891, year: 2016

  9. A combined optical, SEM and STM study of growth spirals

    Indian Academy of Sciences (India)

    Some novel results of a combined sequential study of growth spirals on the basal surface of the richly polytypic CdI2 crystals by optical microscopy, scanning electron microscopy (SEM) and scanning tunneling microscopy (STM) are presented and discussed. In confirmation of the known structural data, the STM pictures ...

  10. SEM Investigation of Superheater Deposits from Biomass-Fired Boilers

    DEFF Research Database (Denmark)

    Jensen, Peter Arendt; Frandsen, Flemming; Hansen, Jørn

    2004-01-01

    , mature superheater deposit samples were extracted from two straw-fired boilers, Masnedø and Ensted, with fuel inputs of 33 MWth and 100 MWth, respectively. SEM (scanning electron microscopy) images and EDX (energy dispersive X-ray) analyses were performed on the deposit samples. Different strategies...

  11. Revolving SEM images visualising 3D taxonomic characters

    DEFF Research Database (Denmark)

    Akkari, Nesrine; Cheung, David Koon-Bong; Enghoff, Henrik

    2013-01-01

    images taken consecutively while rotating the SEM stage 360°, which allows the structure in question to be seen from all angles of view in one plane. Seven new species of the genus Ommatoiulus collected in Tunisia are described: O. chambiensis, O. crassinigripes, O. kefi, O. khroumiriensis, O. xerophilus...

  12. The phase transition of methane caused by pressure change during its seeping up from seepage, revealed by video observation and acoustic reflection data

    Science.gov (United States)

    Aoyama, C.

    2017-12-01

    Methane plumes often exist in the vicinity sea area where shallow type methane hydrates are extracted and they are observed as images displayed on monitors of multi-beam sonar and echo sounder onboard, where methane hydrates are expected at sea bottom on ROV observation data. The hydrates are generally considered to be generated in shallow depths below the sea floor. In this study, author examined annual amount of methane dissolving into seawater by measuring the amount of plume in order to make a quantification of dissolving methane from seafloor. Measurement procedure is plume exploration using multi-beam and quantitative echo sounder , submerge ROV to gushing point at seafloor , calculate the rising speed of methane plumes and examine the phases by monitoring seeping plumes from seafloor with high-definition camera. Components of seeping plumes were defined as methane hydrate particles based on the result by measuring water temperature. From this procedure, it can be concluded that the minimum rising speed of methane hydrate particles from gushing point is 1.6×10-1(m/s) and the maximum of 2.0×10-1(m/s) indicating a difference of more than ten times the gaseous theoretical value of 2.74(m/s). This speed is theoretically closer to the solid speed of the material with physical property similar to hydrates, which is 3.05×10-1 (m/s). Therefore, it can be determined that those particles are in the solid state, immediately above seafloor. To measure the amount of plumes seeping from gushing points funnel-shaped instruments with 20cm diameter opening were used to collect methane plumes in this sea area. This was performed in three different gushing points. As a result, 300ml of methane plume was collected in 643 seconds. Assuming that gushing points exist evenly in the sea area, the annual amount of methane gas seeping from these points will be 7.7×105m3 /per m2. Result shows a large quantity of methane seeping from seafloor into the water. This data is an important

  13. Multidecadal trends in the duration of wet spells and associated intensity of precipitation as revealed by a very dense observational German network

    International Nuclear Information System (INIS)

    Zolina, Olga

    2014-01-01

    Precipitation durations and intensities over the period 1950–2008 are analysed using daily rain gauge data from the Deutsche Wetterdienst raingauge network—one of the densest and most properly maintained precipitation observational networks in Europe. Truncated geometric distribution of the family of discrete distributions was applied for quantifying probability distribution of the durations of wet spells. Further intensities of wet spells of different durations were analysed along with wet spell lengths. During the cold season (October–March) wet periods over the whole of Germany demonstrate a robust pattern of lengthening by about 2–3% for the mean durations of wet spells and up to 6% for extremely long wet periods. This tendency is clearly associated with growing (up to 10% per decade in Eastern Germany) intensity of precipitation during long wet periods (more than 5 days) and the weakening of precipitation events associated with short and moderately long wet periods with both signals being statistically significant. Trends are superimposed with interdecadal variability, which is the strongest in Northern and Central Germany. In the warm season (April–September) there is no robust pan-German trend pattern in the wet spell durations and associated precipitation intensities. Strong structural changes in winter precipitation over Germany potentially imply growing rates of winter ground water recharge over Germany and increasing probability of winter flash and river flooding. (paper)

  14. Surface lowering of the debris-covered area of Kanchenjunga Glacier in the eastern Nepal Himalaya since 1975, as revealed by Hexagon KH-9 and ALOS satellite observations

    Science.gov (United States)

    Lamsal, Damodar; Fujita, Koji; Sakai, Akiko

    2017-12-01

    This study presents the geodetic mass balance of Kanchenjunga Glacier, one of the largest debris-covered glaciers in the easternmost Nepal Himalaya, which possesses a negative mass balance of -0.18 ± 0.17 m w.e. a-1 for the 1975-2010 study period, estimated using digital elevation models (DEMs) generated from Hexagon KH-9 and ALOS PRISM stereo images. Accurate DEMs, with a relative uncertainty of ±5.5 m, were generated from the intensive and manual editing of triangulated irregular network (TIN) models on a stereo MirrorTM/3D Monitor. The glacier ice-flow velocity field was also calculated using a feature-tracking method that was applied to two ALOS orthoimages taken in 2010. The elevation differences between the two DEMs highlight considerable surface lowering across the debris-covered area, and a slight thickening in the accumulation area of Kanchenjunga Glacier between 1975 and 2010. The magnitude and gradient of surface lowering are similar among the six glacier tributaries, even though they are situated at different elevations, which may reflect variations in the ice-flow velocity field. The pattern of surface lowering correlates well with the ice-flow velocity field over the debris-covered portion of the main tributary, suggesting that the glacier dynamics significantly affect surface lowering by altering the emergence velocity along the glacier, particularly in the compressive ablation area. Surface-lowering patterns partially correspond to the supraglacial pond area fraction of the glacier, with enhanced surface lowering observed in areas that possess a larger pond area fraction. These findings support the hypothesis that supraglacial ponds may intensify ice wastage and play a key role in the heterogeneous surface lowering of debris-covered glaciers. The estimated mass loss of Kanchenjunga Glacier is moderate compared with other debris-covered glaciers in neighboring Himalayan regions, which may be due to the lower pond area fraction of Kanchenjunga

  15. In silico and cell-based analyses reveal strong divergence between prediction and observation of T-cell-recognized tumor antigen T-cell epitopes.

    Science.gov (United States)

    Schmidt, Julien; Guillaume, Philippe; Dojcinovic, Danijel; Karbach, Julia; Coukos, George; Luescher, Immanuel

    2017-07-14

    Tumor exomes provide comprehensive information on mutated, overexpressed genes and aberrant splicing, which can be exploited for personalized cancer immunotherapy. Of particular interest are mutated tumor antigen T-cell epitopes, because neoepitope-specific T cells often are tumoricidal. However, identifying tumor-specific T-cell epitopes is a major challenge. A widely used strategy relies on initial prediction of human leukocyte antigen-binding peptides by in silico algorithms, but the predictive power of this approach is unclear. Here, we used the human tumor antigen NY-ESO-1 (ESO) and the human leukocyte antigen variant HLA-A*0201 (A2) as a model and predicted in silico the 41 highest-affinity, A2-binding 8-11-mer peptides and assessed their binding, kinetic complex stability, and immunogenicity in A2-transgenic mice and on peripheral blood mononuclear cells from ESO-vaccinated melanoma patients. We found that 19 of the peptides strongly bound to A2, 10 of which formed stable A2-peptide complexes and induced CD8 + T cells in A2-transgenic mice. However, only 5 of the peptides induced cognate T cells in humans; these peptides exhibited strong binding and complex stability and contained multiple large hydrophobic and aromatic amino acids. These results were not predicted by in silico algorithms and provide new clues to improving T-cell epitope identification. In conclusion, our findings indicate that only a small fraction of in silico -predicted A2-binding ESO peptides are immunogenic in humans, namely those that have high peptide-binding strength and complex stability. This observation highlights the need for improving in silico predictions of peptide immunogenicity. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  16. A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for In-Situ Mars Surface Sample Analysis

    Science.gov (United States)

    Edmunson, J.; Gaskin, J. A.; Jerman, G. A.; Harvey, R. P.; Doloboff, I. J.; Neidholdt, E. L.

    2016-01-01

    The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.

  17. SEM Characterization of an Irradiated Monolithic U-10Mo Fuel Plate

    International Nuclear Information System (INIS)

    Keiser, D.D. Jr.; Jue, J.F.; Robinson, A.B.

    2010-01-01

    Results of scanning electron microscopy (SEM) characterization of irradiated U-7Mo dispersion fuel plates with differing amounts of matrix Si have been reported. However, to date, no results of SEM analysis of irradiated U-Mo monolithic fuel plates have been reported. This paper describes the first SEM characterization results for an irradiated monolithic U-10Mo fuel plate. Two samples from this fuel plate were characterized. One sample was produced from the low-flux side of the fuel plate, and another was produced at the high-flux side of the fuel plate. This characterization focused on the microstructural features present at the U-10Mo foil/cladding interface, particularly the interaction zone that had developed during fabrication and irradiation. In addition, the microstructure of the foil itself was investigated, along with the morphology of the observed fission gas bubbles. It was observed that a Si-rich interaction layer was present at the U-10Mo foil/cladding interface that exhibited relatively good irradiation behavior, and within the U-10Mo foil the microstructural features differed in some respects from what is typically seen in the U-Mo powders of an irradiated dispersion fuel.

  18. Blistering and exfoliation of 304 stainless steel studied by SEM and RBS

    International Nuclear Information System (INIS)

    Braun, M.; Emmoth, B.; Whitton, J.L.

    1981-01-01

    Blistering and exfoliation induced by helium irradiation have been studied in polycrystalline stainless steel with the aim of measuring flake or blister skin thicknesses for different implantation energies in the keV region. The authors present measurements of skin thicknesses determined both by direct SEM observations and RBS techniques. The results of the RBS studies show for all implantation energies used that the thickness measured in target atoms/unit area of a flake equals the calculated implantation range with an accuracy of about 10%. Conversely, the SEM measurements show that swelling gives rise to a geometrical skin thickness much greater than the corresponding implantation range. Thus from the SEM and RBS data swelling as a function of the implantation energy is obtained and the linear relative swelling is shown to be strongly dependent on the energy. In addition a comparison between the skin thickness of blisters and flakes has been made for the same material. Blisters were observed at low implantation temperatures and room temperature while exfoliation occurs at elevated temperatures. The result of this comparison is that within the experimental accuracy the flake and blister thicknesses are the same. (Auth.)

  19. SEM characterization of an irradiated monolithic U-10Mo fuel plate

    International Nuclear Information System (INIS)

    Keiser, D.D. Jr.; Jue, J.F.; Robinson, A.B.; Finlay, M.R.

    2010-01-01

    Results of scanning electron microscopy (SEM) characterization of irradiated U-7Mo dispersion fuel plates with differing amounts of matrix Si have been reported. However, to date, no results of SEM analysis of irradiated U-Mo monolithic fuel plates have been reported. This paper describes the first SEM characterization results for an irradiated monolithic U-10Mo fuel plate. Two samples from this fuel plate were characterized. One sample was produced from the low-flux side of the fuel plate, and another was produced at the high-flux side of the fuel plate. This characterization focused on the microstructural features present at the U-10Mo foil/AA6061 cladding interface, particularly the interaction zone that had developed during fabrication and any continued development during irradiation. In addition, the microstructure of the foil itself was investigated, along with the morphology of the observed fission gas bubbles. It was observed that a Si-rich interaction layer was present at the U-10Mo foil/cladding interface that exhibited relatively good irradiation behavior, and within the U-10Mo foil the microstructural features differed in some respects from what is typically seen in the U-7Mo powders of an irradiated dispersion fuel. (author)

  20. FIB/SEM and SEM/EDS microstructural analysis of metal-ceramic and zirconia-ceramic interfaces.

    Science.gov (United States)

    Massimi, F; Merlati, G; Sebastiani, M; Battaini, P; Menghini, P; Bemporad, E

    2012-01-10

    Recently introduced FIB/SEM analysis in microscopy seems to provide a high-resolution characterization of the samples by 3D (FIB) cross-sectioning and (SEM) high resolution imaging. The aim of this study was to apply the FIB/SEM and SEM/EDS analysis to the interfaces of a metal-ceramic vs. two zirconia-ceramic systems. Plate samples of three different prosthetic systems were prepared in the dental lab following the manufacturers' instructions, where metal-ceramic was the result of a ceramic veneering (porcelain-fused-to-metal) and the two zirconia-ceramic systems were produced by the dedicated CAD-CAM procedures of the zirconia cores (both with final sintering) and then veneered by layered or heat pressed ceramics. In a FIB/SEM equipment (also called DualBeam), a thin layer of platinum (1 μm) was deposited on samples surface crossing the interfaces, in order to protect them during milling. Then, increasingly deeper trenches were milled by a focused ion beam, first using a relatively higher and later using a lower ion current (from 9 nA to 0.28 nA, 30KV). Finally, FEG-SEM (5KV) micrographs (1000-50,000X) were acquired. In a SEM the analysis of the morphology and internal microstructure was performed by 13KV secondary and backscattered electrons signals (in all the samples). The compositional maps were then performed by EDS probe only in the metal-ceramic system (20kV). Despite the presence of many voids in all the ceramic layers, it was possible to identify: (1) the grain structures of the metallic and zirconia substrates, (2) the thin oxide layer at the metal-ceramic interface and its interactions with the first ceramic layer (wash technique), (3) the roughness of the two different zirconia cores and their interactions with the ceramic interface, where the presence of zirconia grains in the ceramic layer was reported in two system possibly due to sandblasting before ceramic firing.

  1. Quantifying Golgi structure using EM: combining volume-SEM and stereology for higher throughput.

    Science.gov (United States)

    Ferguson, Sophie; Steyer, Anna M; Mayhew, Terry M; Schwab, Yannick; Lucocq, John Milton

    2017-06-01

    Investigating organelles such as the Golgi complex depends increasingly on high-throughput quantitative morphological analyses from multiple experimental or genetic conditions. Light microscopy (LM) has been an effective tool for screening but fails to reveal fine details of Golgi structures such as vesicles, tubules and cisternae. Electron microscopy (EM) has sufficient resolution but traditional transmission EM (TEM) methods are slow and inefficient. Newer volume scanning EM (volume-SEM) methods now have the potential to speed up 3D analysis by automated sectioning and imaging. However, they produce large arrays of sections and/or images, which require labour-intensive 3D reconstruction for quantitation on limited cell numbers. Here, we show that the information storage, digital waste and workload involved in using volume-SEM can be reduced substantially using sampling-based stereology. Using the Golgi as an example, we describe how Golgi populations can be sensed quantitatively using single random slices and how accurate quantitative structural data on Golgi organelles of individual cells can be obtained using only 5-10 sections/images taken from a volume-SEM series (thereby sensing population parameters and cell-cell variability). The approach will be useful in techniques such as correlative LM and EM (CLEM) where small samples of cells are treated and where there may be variable responses. For Golgi study, we outline a series of stereological estimators that are suited to these analyses and suggest workflows, which have the potential to enhance the speed and relevance of data acquisition in volume-SEM.

  2. Contrast of Backscattered Electron SEM Images of Nanoparticles on Substrates with Complex Structure

    Directory of Open Access Journals (Sweden)

    Thomas Kowoll

    2017-01-01

    Full Text Available This study is concerned with backscattered electron scanning electron microscopy (BSE SEM contrast of complex nanoscaled samples which consist of SiO2 nanoparticles (NPs deposited on indium-tin-oxide covered bulk SiO2 and glassy carbon substrates. BSE SEM contrast of NPs is studied as function of the primary electron energy and working distance. Contrast inversions are observed which prevent intuitive interpretation of NP contrast in terms of material contrast. Experimental data is quantitatively compared with Monte-Carlo- (MC- simulations. Quantitative agreement between experimental data and MC-simulations is obtained if the transmission characteristics of the annular semiconductor detector are taken into account. MC-simulations facilitate the understanding of NP contrast inversions and are helpful to derive conditions for optimum material and topography contrast.

  3. Contrast of Backscattered Electron SEM Images of Nanoparticles on Substrates with Complex Structure.

    Science.gov (United States)

    Kowoll, Thomas; Müller, Erich; Fritsch-Decker, Susanne; Hettler, Simon; Störmer, Heike; Weiss, Carsten; Gerthsen, Dagmar

    2017-01-01

    This study is concerned with backscattered electron scanning electron microscopy (BSE SEM) contrast of complex nanoscaled samples which consist of SiO 2 nanoparticles (NPs) deposited on indium-tin-oxide covered bulk SiO 2 and glassy carbon substrates. BSE SEM contrast of NPs is studied as function of the primary electron energy and working distance. Contrast inversions are observed which prevent intuitive interpretation of NP contrast in terms of material contrast. Experimental data is quantitatively compared with Monte-Carlo- (MC-) simulations. Quantitative agreement between experimental data and MC-simulations is obtained if the transmission characteristics of the annular semiconductor detector are taken into account. MC-simulations facilitate the understanding of NP contrast inversions and are helpful to derive conditions for optimum material and topography contrast.

  4. XRD and SEM analysis of hydroxyapatite during immersion in stimulated physiological solutions

    International Nuclear Information System (INIS)

    Yusof Abdullah; Idris Besar; Rosmamuhamadani Ramli; Abd Razak Daud

    2000-01-01

    XRD and SEM techniques were used to analyse the apatite layer developed on the synthetic hydroxyapatite surface following immersion in the simulated body fluid (SBF) that mimics the conditions of material experiences after implantation in the human body. Initially, the new layers formed after 7 day's incubation and increased with immersion time as crystallization of apatite phase. The XRD confirmed that the deposited layer was hydroxyapatite and crystallographically. With time, the crystal growth become more random and the intensity of the peaks decreased. During immersion, hydroxyapatite was precipitated from the SBF and coherently scattered with very small crystal. The SEM observation shows that the new precipitates were increased as well as incubation period increased. Therefore, hydroxyapatite ceramics are suggested to have very good biocompatibility. (Author)

  5. Three dimensional rock microstructures: insights from FIB-SEM tomography

    Science.gov (United States)

    Drury, Martyn; Pennock, Gill; de Winter, Matthijs

    2016-04-01

    Most studies of rock microstructures investigate two-dimensional sections or thin slices of three dimensional grain structures. With advances of X-ray and electron tomography methods the 3-D microstructure can be(relatively) routinely investigated on scales from a few microns to cm. 3D studies are needed to investigate the connectivity of microstructures and to test the assumptions we use to calculate 3D properties from 2D sections. We have used FIB-SEM tomography to study the topology of melts in synthetic olivine rocks, 3D crystal growth microstructures, pore networks and subgrain structures. The technique uses a focused ion beam to make serial sections with a spacing of tens to hundreds of nanometers. Each section is then imaged or mapped using the electron beam. The 3D geometry of grains and subgrains can be investigated using orientation contrast or EBSD mapping. FIB-SEM tomography of rocks and minerals can be limited by charging of the uncoated surfaces exposed by the ion beam. The newest generation of FIB-SEMs have much improved low voltage imaging capability allowing high resolution charge free imaging. Low kV FIB-SEM tomography is now widely used to study the connectivity of pore networks. In-situ fluids can also be studied using cryo-FIB-SEM on frozen samples, although special freezing techniques are needed to avoid artifacts produced by ice crystallization. FIB-SEM tomography is complementary, in terms of spatial resolution and sampled volume, to TEM tomography and X-ray tomography, and the combination of these methods can cover a wide range of scales. Our studies on melt topology in synthetic olivine rocks with a high melt content show that many grain boundaries are wetted by nanometre scale melt layers that are too thin to resolve by X-ray tomography. A variety of melt layer geometries occur consistent with several mechanisms of melt layer formation. The nature of melt geometries along triple line junctions and quadruple points can be resolved

  6. Morphology of the European species of the aphid genus Eulachnus (Hemiptera: Aphididae: Lachninae) - A SEM comparative and integrative study.

    Science.gov (United States)

    Kanturski, Mariusz; Karcz, Jagna; Wieczorek, Karina

    2015-09-01

    Scanning electron microscopy (SEM) methods were used for the first time to elucidate the external morphology of the European species of the genus Eulachnus (Hemiptera: Aphididae: Lachninae), a representative genus of the conifer-feeding aphids tribe Eulachnini. We examined and compared the external morphology of apterous and alate viviparous females from the parthenogenetic generation as well as oviparous females and alate males belonging to the sexual generation. FE-SEM images based on HMDS and cryo-SEM preparation techniques revealed better image quality than the CPD technique in regard to surface tension and morphological signs of cell deteriorations (i.e., existence of depressions, drying artifacts and membrane blebs). Three morphologically different species groups "agilis", "brevipilosus" and "cembrae" were proposed due to the differences in head, antennae, legs and dorsal chaetotaxy as well as dorsal sclerotization. The most characteristic features and differences of representatives of these groups are presented and discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Critical factors in SEM 3D stereo microscopy

    International Nuclear Information System (INIS)

    Marinello, F; Savio, E; Bariani, P; Horsewell, A; De Chiffre, L

    2008-01-01

    This work addresses dimensional measurements performed with the scanning electron microscope (SEM) using 3D reconstruction of surface topography through stereo-photogrammetry. The paper presents both theoretical and experimental investigations, on the effects of instrumental variables and measurement parameters on reconstruction accuracy. Investigations were performed on a novel sample, specifically developed and implemented for the tests. The description is based on the model function introduced by Piazzesi and adapted for eucentrically tilted stereopairs. Two main classes of influencing factors are recognized: the first one is related to the measurement operation and the instrument set-up; the second concerns the quality of scanned images and represents the major criticality in the application of SEMs for 3D characterizations

  8. Three dimensional imaging of surface geometry in SEM

    International Nuclear Information System (INIS)

    Slowko, W.

    1997-01-01

    A great advantage of scanning electron microscopy (SEM) is its ability of the surface topography in the way as a human eye is accustomed to see lights and shadows on macroobjects. However, SEM's can hardly display vertical dimensions of the structures. One of possible solutions is reconstruction of the surface profiles by directional detection of secondary electrons and proper signal processing. However, the surface profile still gives two dimensional information and the method should be extended to obtain fully three dimensional imaging. The extension consists in a simultaneous reconstruction of the surface profiles in two perpendicular directions (x and y) and their superposition. The solution proposed is based on a quadrupole detector system and a computer or analogue system for signal processing. Quantitative data of the surface topography can be displayed in many manners in the system of two or three co-ordinates with use of pseudo-colour for the altitude coding. (author)

  9. SEM and Raman studies of CNT films on porous Si

    Science.gov (United States)

    Belka, R.; Keczkowska, J.; Suchańska, M.; Firek, P.; Wronka, H.; Kozłowski, M.; Radomska, J.; Czerwosz, E.; Craciunoiu, F.

    2017-08-01

    Carbon nanotube (CNT) films deposited on different porous silica substrates were studied by Scanning Electron Microscopy (SEM) and Raman Spectroscopy (RS). The films samples were prepared by a two-step method consisting of PVD and CVD processes. In the first step the nanocomposite Ni-C film was obtained by evaporation in dynamic vacuum from two separated sources of fullerenes and nickel acetate. Those films were deposited on porous silica and DLC/porous silica substrates. Analysis of SEM imaging showed that the obtained film are composed of carbon nanotubes, the distribution, size and quality of which depend on the type of substrate. The CNT films were studied by RS method to determine the influence of the substrate type on disordering of carbonaceous structure and quality of CNT in deposited films.

  10. High incorrect use of the standard error of the mean (SEM) in original articles in three cardiovascular journals evaluated for 2012.

    Science.gov (United States)

    Wullschleger, Marcel; Aghlmandi, Soheila; Egger, Marcel; Zwahlen, Marcel

    2014-01-01

    In biomedical journals authors sometimes use the standard error of the mean (SEM) for data description, which has been called inappropriate or incorrect. To assess the frequency of incorrect use of SEM in articles in three selected cardiovascular journals. All original journal articles published in 2012 in Cardiovascular Research, Circulation: Heart Failure and Circulation Research were assessed by two assessors for inappropriate use of SEM when providing descriptive information of empirical data. We also assessed whether the authors state in the methods section that the SEM will be used for data description. Of 441 articles included in this survey, 64% (282 articles) contained at least one instance of incorrect use of the SEM, with two journals having a prevalence above 70% and "Circulation: Heart Failure" having the lowest value (27%). In 81% of articles with incorrect use of SEM, the authors had explicitly stated that they use the SEM for data description and in 89% SEM bars were also used instead of 95% confidence intervals. Basic science studies had a 7.4-fold higher level of inappropriate SEM use (74%) than clinical studies (10%). The selection of the three cardiovascular journals was based on a subjective initial impression of observing inappropriate SEM use. The observed results are not representative for all cardiovascular journals. In three selected cardiovascular journals we found a high level of inappropriate SEM use and explicit methods statements to use it for data description, especially in basic science studies. To improve on this situation, these and other journals should provide clear instructions to authors on how to report descriptive information of empirical data.

  11. A hybrid 3D SEM reconstruction method optimized for complex geologic material surfaces.

    Science.gov (United States)

    Yan, Shang; Adegbule, Aderonke; Kibbey, Tohren C G

    2017-08-01

    Reconstruction methods are widely used to extract three-dimensional information from scanning electron microscope (SEM) images. This paper presents a new hybrid reconstruction method that combines stereoscopic reconstruction with shape-from-shading calculations to generate highly-detailed elevation maps from SEM image pairs. The method makes use of an imaged glass sphere to determine the quantitative relationship between observed intensity and angles between the beam and surface normal, and the detector and surface normal. Two specific equations are derived to make use of image intensity information in creating the final elevation map. The equations are used together, one making use of intensities in the two images, the other making use of intensities within a single image. The method is specifically designed for SEM images captured with a single secondary electron detector, and is optimized to capture maximum detail from complex natural surfaces. The method is illustrated with a complex structured abrasive material, and a rough natural sand grain. Results show that the method is capable of capturing details such as angular surface features, varying surface roughness, and surface striations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Structural characterization of degradation of ODS composite using SEM and XRM techniques

    Directory of Open Access Journals (Sweden)

    Oladayo OLANIRAN

    2017-07-01

    Full Text Available The structural characteristics and mechanisms of corrosion and wear of oxide dispersion strengthened stainless steel composite were investigated. Insitu synchrotron x-ray tomography was used as experimental technique for degradation analysis from the corrosion and tribology studies. Corrosion study was carried out using potential dynamic techniques while the tribology experiments were conducted using a tribometer with ball on disc method. The x-ray micro tomography data gave chronological description of crack initiation and propagation in 3D and revealed that pitting did not result from the oxide inclusion. The results also revealed the surface imaging capacity of SEM and XRM’s capability for imaging internal structures. Taber index measurement was used as a complimenting tool for tribology measurements. Tribological behaviour of the sinter Oxide Dispersion Strengthened (ODS steel composite depends on both the composition of the composite and the loading system.

  13. Classification and printability of EUV mask defects from SEM images

    Science.gov (United States)

    Cho, Wonil; Price, Daniel; Morgan, Paul A.; Rost, Daniel; Satake, Masaki; Tolani, Vikram L.

    2017-10-01

    Classification and Printability of EUV Mask Defects from SEM images EUV lithography is starting to show more promise for patterning some critical layers at 5nm technology node and beyond. However, there still are many key technical obstacles to overcome before bringing EUV Lithography into high volume manufacturing (HVM). One of the greatest obstacles is manufacturing defect-free masks. For pattern defect inspections in the mask-shop, cutting-edge 193nm optical inspection tools have been used so far due to lacking any e-beam mask inspection (EBMI) or EUV actinic pattern inspection (API) tools. The main issue with current 193nm inspection tools is the limited resolution for mask dimensions targeted for EUV patterning. The theoretical resolution limit for 193nm mask inspection tools is about 60nm HP on masks, which means that main feature sizes on EUV masks will be well beyond the practical resolution of 193nm inspection tools. Nevertheless, 193nm inspection tools with various illumination conditions that maximize defect sensitivity and/or main-pattern modulation are being explored for initial EUV defect detection. Due to the generally low signal-to-noise in the 193nm inspection imaging at EUV patterning dimensions, these inspections often result in hundreds and thousands of defects which then need to be accurately reviewed and dispositioned. Manually reviewing each defect is difficult due to poor resolution. In addition, the lack of a reliable aerial dispositioning system makes it very challenging to disposition for printability. In this paper, we present the use of SEM images of EUV masks for higher resolution review and disposition of defects. In this approach, most of the defects detected by the 193nm inspection tools are first imaged on a mask SEM tool. These images together with the corresponding post-OPC design clips are provided to KLA-Tencor's Reticle Decision Center (RDC) platform which provides ADC (Automated Defect Classification) and S2A (SEM

  14. A simplified method for scanning electron microscopy (SEM) autoradiography

    International Nuclear Information System (INIS)

    Shahar, A.; Lasher, R.

    1980-01-01

    The combination of autoradiography with SEM provides a valuable tool for the study of labeled biological materials, but the previously described methods are complicated because they call first for the removal of gelatin from the film emulsion and this is then followed by deposition of gold vapor on the specimen. The authors describe a much simpler method which can easily be adapted to routine examination of cell cultures. In this method, gelatin is not removed; the film is coated with vaporized carbon only. This procedure permits visualization of both cellular image and distribution of silver grains. (Auth.)

  15. La semántica en la Web

    OpenAIRE

    Roger, Sandra

    2004-01-01

    El propósito de este trabajo es presentar la motivación de nuestra línea de investigación, metas y desarrollos futuros. Fundamentalmente, nuestro interés se centrará en poder capturar el potencial de las técnicas y paradigmas basadas en conocimiento semántico para la representación de conocimiento, la localización, compartición e integración de recursos a mediante la WWW.

  16. Exploring the interior of cuticles and compressions of fossil plants by FIB-SEM milling and image microscopy.

    Science.gov (United States)

    Sender, L M; Escapa, I; Benedetti, A; Cúneo, R; Diez, J B

    2018-01-01

    We present the first study of cuticles and compressions of fossil leaves by Focused Ion Beam Scanning Electron Microscopy (FIB-SEM). Cavities preserved inside fossil leaf compressions corresponding to substomatal chambers have been observed for the first time and several new features were identified in the cross-section cuts. These results open a new way in the investigation of the three-dimensional structures of both micro- and nanostructural features of fossil plants. Moreover, the application of the FIB-SEM technique to both fossils and extant plant remains represent a new source of taxonomical, palaeoenvironmental and palaeoclimatic information. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  17. Sexual Arousal and Sexually Explicit Media (SEM): Comparing Patterns of Sexual Arousal to SEM and Sexual Self-Evaluations and Satisfaction Across Gender and Sexual Orientation.

    Science.gov (United States)

    Hald, Gert Martin; Stulhofer, Aleksandar; Lange, Theis

    2018-03-01

    Investigations of patterns of sexual arousal to certain groups of sexually explicit media (SEM) in the general population in non-laboratory settings are rare. Such knowledge could be important to understand more about the relative specificity of sexual arousal in different SEM users. (i) To investigate whether sexual arousal to non-mainstream vs mainstream SEM contents could be categorized across gender and sexual orientation, (ii) to compare levels of SEM-induced sexual arousal, sexual satisfaction, and self-evaluated sexual interests and fantasies between non-mainstream and mainstream SEM groups, and (iii) to explore the validity and predictive accuracy of the Non-Mainstream Pornography Arousal Scale (NPAS). Online cross-sectional survey of 2,035 regular SEM users in Croatia. Patterns of sexual arousal to 27 different SEM themes, sexual satisfaction, and self-evaluations of sexual interests and sexual fantasies. Groups characterized by sexual arousal to non-mainstream SEM could be identified across gender and sexual orientation. These non-mainstream SEM groups reported more SEM use and higher average levels of sexual arousal across the 27 SEM themes assessed compared with mainstream SEM groups. Only few differences were found between non-mainstream and mainstream SEM groups in self-evaluative judgements of sexual interests, sexual fantasies, and sexual satisfaction. The internal validity and predictive accuracy of the NPAS was good across most user groups investigated. The findings suggest that in classified non-mainstream SEM groups, patterns of sexual arousal might be less fixated and category specific than previously assumed. Further, these groups are not more judgmental of their SEM-related sexual arousal patterns than groups characterized by patterns of sexual arousal to more mainstream SEM content. Moreover, accurate identification of non-mainstream SEM group membership is generally possible across gender and sexual orientation using the NPAS. Hald GM

  18. Super-resolution for asymmetric resolution of FIB-SEM 3D imaging using AI with deep learning.

    Science.gov (United States)

    Hagita, Katsumi; Higuchi, Takeshi; Jinnai, Hiroshi

    2018-04-12

    Scanning electron microscopy equipped with a focused ion beam (FIB-SEM) is a promising three-dimensional (3D) imaging technique for nano- and meso-scale morphologies. In FIB-SEM, the specimen surface is stripped by an ion beam and imaged by an SEM installed orthogonally to the FIB. The lateral resolution is governed by the SEM, while the depth resolution, i.e., the FIB milling direction, is determined by the thickness of the stripped thin layer. In most cases, the lateral resolution is superior to the depth resolution; hence, asymmetric resolution is generated in the 3D image. Here, we propose a new approach based on an image-processing or deep-learning-based method for super-resolution of 3D images with such asymmetric resolution, so as to restore the depth resolution to achieve symmetric resolution. The deep-learning-based method learns from high-resolution sub-images obtained via SEM and recovers low-resolution sub-images parallel to the FIB milling direction. The 3D morphologies of polymeric nano-composites are used as test images, which are subjected to the deep-learning-based method as well as conventional methods. We find that the former yields superior restoration, particularly as the asymmetric resolution is increased. Our super-resolution approach for images having asymmetric resolution enables observation time reduction.

  19. Study of SEM preparation artefacts with correlative microscopy: Cell shrinkage of adherent cells by HMDS-drying.

    Science.gov (United States)

    Katsen-Globa, Alisa; Puetz, Norbert; Gepp, Michael M; Neubauer, Julia C; Zimmermann, Heiko

    2016-11-01

    One of the often reported artefacts during cell preparation to scanning electron microscopy (SEM) is the shrinkage of cellular objects, that mostly occurs at a certain time-dependent stage of cell drying. Various methods of drying for SEM, such as critical point drying, freeze-drying, as well as hexamethyldisilazane (HMDS)-drying, were usually used. The latter becomes popular since it is a low cost and fast method. However, the correlation of drying duration and real shrinkage of objects was not investigated yet. In this paper, cell shrinkage at each stage of preparation for SEM was studied. We introduce a shrinkage coefficient using correlative light microscopy (LM) and SEM of the same human mesenchymal stem cells (hMSCs). The influence of HMDS-drying duration on the cell shrinkage is shown: the longer drying duration, the more shrinkage is observed. Furthermore, it was demonstrated that cell shrinkage is inversely proportional to cultivation time: the longer cultivation time, the more cell spreading area and the less cell shrinkage. Our results can be applicable for an exact SEM quantification of cell size and determination of cell spreading area in engineering of artificial cellular environments using biomaterials. SCANNING 38:625-633, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

  20. Determination of gel content and SEM morphology for sago-PVA blends film

    International Nuclear Information System (INIS)

    Sarada Idris; Zulkafli Ghazali; Kamarudin Hashim

    2006-01-01

    Blends of polyvinyl alcohol and sago starch have been prepared to evaluate the potential of producing biodegradable products. Glycerol was introduced in the blends to improve the flexibility of the films as plasticizer in order more flexible film. These blends have been subjected to electron beam irradiation to evaluate and characterized radiation effect on the blends. Subsequently films were produced from this blend. The gel content of un-irradiated and irradiated films as evidence of cross linking was measured and discussed. This paper also discuss the films morphology from Scanning Electron Microscopy(SEM) observation. (Author)

  1. Mathematics revealed

    CERN Document Server

    Berman, Elizabeth

    1979-01-01

    Mathematics Revealed focuses on the principles, processes, operations, and exercises in mathematics.The book first offers information on whole numbers, fractions, and decimals and percents. Discussions focus on measuring length, percent, decimals, numbers as products, addition and subtraction of fractions, mixed numbers and ratios, division of fractions, addition, subtraction, multiplication, and division. The text then examines positive and negative numbers and powers and computation. Topics include division and averages, multiplication, ratios, and measurements, scientific notation and estim

  2. Effect of two bleaching agents on enamel morphology: a SEM study

    Directory of Open Access Journals (Sweden)

    Ghavam M.

    2005-05-01

    Full Text Available Statement of Problem: Bleaching materials are able to change the surface morphology as well as mineral and organic content of tooth structure. Considering that bleaching is done for aesthetic purpose, awareness of the possible effect of these materials on hard tissue is important, because it may affect the restorative treatments. Purpose: The aim of this study was comparing the effect of two bleaching materials, Kimia and Ultradent both containing 35% H2O2, on tooth enamel by SEM. Materials and Methods: Five intact central incisors were cut into three sections vertically and each part was randomly divided into three groups. Group 1 (control, without any bleaching. Group 2, bleached with Kimia 35% H2O2. Group 3, bleached with Ultradent 35% H2O2. Each tooth served as its own control. Then the samples were observed by SEM with 250 and 500 magnifications. Results: In the control group some scratches and small white grains were observed which seems to be the result of mastication trauma and pumice powder. In the other groups, morphologic changes like increased surface roughness, deepening of cracks, rod exposure and presence of new cracks were observed. The two experimental materials did not differ in these regards. Conclusion: It seems that both studied materials have limited destructive effects on tooth enamel which seems to be of no clinical importance.

  3. SEM AutoAnalysis: enhancing photomask and NIL defect disposition and review

    Science.gov (United States)

    Schulz, Kristian; Egodage, Kokila; Tabbone, Gilles; Ehrlich, Christian; Garetto, Anthony

    2017-06-01

    For defect disposition and repair verification regarding printability, AIMS™ is the state of the art measurement tool in industry. With its unique capability of capturing aerial images of photomasks it is the one method that comes closest to emulating the printing behaviour of a scanner. However for nanoimprint lithography (NIL) templates aerial images cannot be applied to evaluate the success of a repair process. Hence, for NIL defect dispositioning scanning, electron microscopy (SEM) imaging is the method of choice. In addition, it has been a standard imaging method for further root cause analysis of defects and defect review on optical photomasks which enables 2D or even 3D mask profiling at high resolutions. In recent years a trend observed in mask shops has been the automation of processes that traditionally were driven by operators. This of course has brought many advantages one of which is freeing cost intensive labour from conducting repetitive and tedious work. Furthermore, it reduces variability in processes due to different operator skill and experience levels which at the end contributes to eliminating the human factor. Taking these factors into consideration, one of the software based solutions available under the FAVOR® brand to support customer needs is the aerial image evaluation software, AIMS™ AutoAnalysis (AAA). It provides fully automated analysis of AIMS™ images and runs in parallel to measurements. This is enabled by its direct connection and communication with the AIMS™tools. As one of many positive outcomes, generating automated result reports is facilitated, standardizing the mask manufacturing workflow. Today, AAA has been successfully introduced into production at multiple customers and is supporting the workflow as described above. These trends indeed have triggered the demand for similar automation with respect to SEM measurements leading to the development of SEM AutoAnalysis (SAA). It aims towards a fully automated SEM image

  4. Diferenciador semántico: bipolaridad del espacio semántico, un problema de medida del significado

    OpenAIRE

    Álvarez C., Ramiro

    2012-01-01

    En relación con el supuesto de bipolaridad y su aspecto recíprocamente antagónico, Osgood y otros (1957) han ligado su modelo de espacio semántico a la teoría del aprendizaje. Plantean la hipótesis de que cierto estimulo externo, o signo, desencadena un proceso mediacional interno (nn) el cual se constituye en emisor de estímulos (rm 15m). Este es el rm mediacional que contendría el significado del signo. La teoría de mediación la relacionan con el supuesto de bipolaridad en los siguientes té...

  5. Comparing the detection of iron-based pottery pigment on a carbon-coated sherd by SEM-EDS and by Micro-XRF-SEM.

    Science.gov (United States)

    Pendleton, Michael W; Washburn, Dorothy K; Ellis, E Ann; Pendleton, Bonnie B

    2014-03-01

    The same sherd was analyzed using a scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and a micro X-ray fluorescence tube attached to a scanning electron microscope (Micro-XRF-SEM) to compare the effectiveness of elemental detection of iron-based pigment. To enhance SEM-EDS mapping, the sherd was carbon coated. The carbon coating was not required to produce Micro-XRF-SEM maps but was applied to maintain an unbiased comparison between the systems. The Micro-XRF-SEM analysis was capable of lower limits of detection than that of the SEM-EDS system, and therefore the Micro-XRF-SEM system could produce elemental maps of elements not easily detected by SEM-EDS mapping systems. Because SEM-EDS and Micro-XRF-SEM have been used for imaging and chemical analysis of biological samples, this comparison of the detection systems should be useful to biologists, especially those involved in bone or tooth (hard tissue) analysis.

  6. Application of FE-SEM with elemental analyzer for irradiated fuel materials

    International Nuclear Information System (INIS)

    Sasaki, Shinji; Maeda, Koji; Yamada, A.

    2012-01-01

    It is important to study the irradiation behavior of the uranium-plutonium mixed oxide fuels (MOX fuels) for development of fast reactor fuels. During irradiation in a fast reactor, the changes of microstructures and the changes of element distributions along radial direction occur in the MOX fuels because of a radial temperature gradient. In order to make detailed observations of microstructure and elemental analyses of fuel samples, a field emission scanning electron microscope (FE-SEM) equipped with a wavelength-dispersive X-ray spectrometer (WDX) and an energy-dispersive X-ray spectrometer (EDX) were installed in a hot laboratory. Because fuel samples have high radioactivities and emit α-particles, the instrument was modified correspondingly. The notable modified points were as follows. 1) To prevent leakage of radioactive materials, the instrument was attached to a remote control air-tight sample transfer unit between a shielded hot cell and the FE-SEM. 2) To protect operators and the instruments from radiation, the FE-SEM was installed in a lead shield box and the control unit was separately located outside the box. After the installation, the microscopy and elemental analyses were made on low burnup fuel samples. High resolution images were obtained on the fuel sample surface. The characteristic X-rays (U, Pu) emitted from the fuel sample surface measured along radial direction successfully. Thereby, it was able to grasp the change of U, Pu radial distribution after irradiation. The technique has the great advantage of being able to evaluate the changes of microstructures and the changes of element distributions of MOX fuels due to irradiation. In future work, samples of even higher radioactivity will be observed and analyzed. (author)

  7. Structure and surface morphology studies of cerium oxide system using XRD and SEM analysis

    International Nuclear Information System (INIS)

    Ahmad Jais Alimin; Farid Nasir Ani; Wan Azelee Wan Abu Bakar

    2000-01-01

    Conventional Precious Group Materials (PGM) catalyst systems have been using CeO 2 as an Oxygen Storage Capacity component in the catalyst washcoat. Due to the limitations of the PGM catalyst, researches are now focusing on improving or replacing this conventional system. In a previous work, the potential of a copper-ceria (Cu-Ce) oxide as a catalyst system has been identified. In this paper, the morphology and characterisation of Cu-Ce oxides analysed using XRD and SEM will be described. The Cu-Ce samples were prepared at a fixed ratio under temperatures of 400 o C and 800 o C. XRD diffractograms showed CeO 2 is in a cubic phase at 400 o C and 800 o C. At 800 o C, the CuO particle is visible, presumably has incorporated with the lattice structure of ceria, indicating an absent of solid state condition between copper and ceria. Analysis by SEM revealed significant increase in particle sizes with increasing calcination temperatures. (Author)

  8. Site specific SEM/FIB/TEM for analysis of lubricated sliding wear of aluminium alloy composites

    International Nuclear Information System (INIS)

    Walker, J C; Jones, H; Rainforth, W M

    2006-01-01

    Although extensive research has been undertaken into the dry sliding wear of aluminium alloys, only limited work has been reported on lubricated wear. In this paper, the lubricated sliding wear of some powder derived aluminium alloy composites is reported. Stereo pairs of the worn surface were obtained in the SEM and digitally reconstructed to give an accurate projection of the surface topography. Analysis of the average surface roughness (R a ) along chosen sections provided quantitative information about the wear mechanism. Following this, dual beam focused ion beam (FIB) was undertaken to further explore the features revealed by the SEM surface reconstructions, with TEM sections removed from selected regions. Surface deformation was confined to a narrow layer, typically 1μm thick. Subgrain size within the subsurface layer was comparable to that found in dry sliding wear tests. Reinforcement fracture occurred in the surface particles only. The resultant fragments were often incorporated back into the surface following detachment, such that the total volume fraction reinforcement at the surface was greater than in the bulk. Thus, the dynamic surface topography was a result of three factors: surface deformation, local detachment of reinforcement and re-incorporation of the fragments back into the surface

  9. Cultivo sem solo do morangueiro Strawberry soilless cultivation

    Directory of Open Access Journals (Sweden)

    Gustavo Giménez

    2008-02-01

    Full Text Available O morangueiro é uma cultura importante em vários países, principalmente nos Estados Unidos e na Europa, por suas características sensoriais, propriedades nutritivas e por sua rentabilidade. O cultivo comercial sem solo de morangueiro está bem desenvolvido na Europa, onde tem permitido um aumento da produtividade e qualidade da produção assim como a ampliação da oferta do produto ao longo do ano. Predomina o sistema aberto, em sacolas ou vasos com diferentes tipos de substratos, utilizando-se densidades de 8 a 12plantas m-2. As produtividades obtidas estão entre 5 e 10kg m-2. Para isolar as plantas do solo e facilitar o manejo da cultura, os vasos ou sacolas são suspensos a uma altura entre 0,8 e 1m da superfície do solo. A composição da solução nutritiva é variável, refletindo as diferentes condições produtivas. As mudas são produzidas principalmente em bandejas com substrato, a partir de pontas de estolões obtidas da multiplicação de plantas matrizes provenientes da propagação in vitro. No Brasil, o cultivo sem solo de morangueiro é ainda incipiente e os resultados produtivos e econômicos têm sido insatisfatórios, principalmente por falta de informações de pesquisas capazes de indicar sistemas apropriados de cultivo para as condições locais. É necessário desenvolver sistemas sustentáveis, preferencialmente fechados, combinando alta produtividade e elevada eficiência de utilização da água e dos nutrientes. No presente trabalho, são revisados os principais aspectos da produção em sistemas de cultivo sem solo de mudas e fruta de morangueiro. São descritos a produção de mudas, os sistemas e as soluções nutritivas empregadas em diferentes países. Ao final, são feitas inferências sobre a possibilidade de adoção e geração do sistema de cultivo sem solo apropriado para as condições brasileiras.Strawberry is a very important crop in Europe and USA due to its nutritional and sensorial

  10. Filler segmentation of SEM paper images based on mathematical morphology.

    Science.gov (United States)

    Ait Kbir, M; Benslimane, Rachid; Princi, Elisabetta; Vicini, Silvia; Pedemonte, Enrico

    2007-07-01

    Recent developments in microscopy and image processing have made digital measurements on high-resolution images of fibrous materials possible. This helps to gain a better understanding of the structure and other properties of the material at micro level. In this paper SEM image segmentation based on mathematical morphology is proposed. In fact, paper models images (Whatman, Murillo, Watercolor, Newsprint paper) selected in the context of the Euro Mediterranean PaperTech Project have different distributions of fibers and fillers, caused by the presence of SiAl and CaCO3 particles. It is a microscopy challenge to make filler particles in the sheet distinguishable from the other components of the paper surface. This objectif is reached here by using switable strutural elements and mathematical morphology operators.

  11. Afasia global sem hemiparesia: AVC ou transtorno conversivo?

    OpenAIRE

    Negreiros,Daniel Philippi de; Fregni,Felipe; Scalco,Andréia Zavaloni

    2007-01-01

    CONTEXTO: A realização de diagnóstico neurológico e psiquiátrico em ambiente de emergência hospitalar com freqüência é uma tarefa complexa e exige colaboração interdisciplinar. Um dos diagnósticos diferenciais de doenças neurológicas é o transtorno conversivo, cuja característica principal é a presença de sintomas afetando funções motoras ou sensoriais, que sugerem desordem clínica ou neurológica, porém sem doença orgânica subjacente que explique o quadro. RELATO DE CASO: Os autores relatam o...

  12. SEM-EDX--a useful tool for forensic examinations

    International Nuclear Information System (INIS)

    Zadora, G.; Brozek-Mucha, Z.

    2003-01-01

    There are two main aims of forensic examination of the physical evidences. The first aim is comparison of the evidence with the reference material (called discrimination). The task is to find out whether they could have come from the same object. The second aim, when there is no comparative material available, is a classification of the evidence sample into a group of objects taking into account its specific chemical and physical properties. Scanning electron microscopy with energy dispersive X-ray spectrometry (SEM-EDX) is a powerful tool for forensic scientists to classify and discriminate evidence material because they can simultaneously examine the morphology and the elemental composition of objects. Moreover, the obtained results could be enhanced using some methods of chemometric analysis. A few examples of problems related to the classification and discrimination of selected types of microtraces are presented

  13. Modification of the microstructure of the films formed by gamma irradiated starch examined by SEM

    Science.gov (United States)

    Cieśla, K.; Sartowska, B.

    2016-01-01

    The paper concerns the effect of gamma irradiation carried out for starch on the microstructure of the films prepared using the starch and its composition with sodium laurate (NaLau) and cetyltrimethylammonium bromide (CTAB) studied by scanning electron microscopy (SEM). Potato starch was irradiated with 60Co gamma rays applying a dose of 30 kGy. Films were prepared by the solution casting method with the addition of 30 wt% glycerol as a plasticizer. Films containing NaLau and CTAB were prepared after performing the procedure, leading to starch-surfactant complexes. Mechanical tests and wetting angle measurements were performed for the films. SEM observations were carried out for the surfaces, fractures and/or sections of the films subjected to chemical fixation and for the dried films. The films obtained using irradiated starch are characterized by a smoother and more homogeneous structure as compared to those based on the non-irradiated starch. Besides, a number of small precipitates were observed on the films surfaces after drying and the number of those precipitates seemed to be higher after irradiation. The results can be related to differences in the microstructure of gels formed on the intermediate step of the films preparation and to the presence of two phases in the system and might serve for explanation of the radiation induced improvement of the hydrophilic/hydrophobic properties, a modification of the mechanical properties of the films, as well as for the changes of those properties resulting after storage.

  14. Dynamic Low-Vacuum Scanning Electron Microscope Freeze Drying Observation for Fresh Water Algae

    International Nuclear Information System (INIS)

    Mohsen, H.T.; Ghaly, W.A.; Zahran, N.F.; Helal, A.I.

    2010-01-01

    A new perpetration method for serving in dynamic examinations of the fresh water algae is developed in connection with the Low-Vacuum Scanning Electron Microscope (LV-SEM) freeze drying technique. Specimens are collected from fresh water of Ismailia channel then transferred directly to freeze by liquid nitrogen and dried in the chamber of the scanning electron microscope in the low vacuum mode. Scanning electron micrographs revealed that the drying method presented the microstructure of algae. Dehydration in a graded ethanol series is not necessary in the new method. Dried algae specimen is observed in SEM high vacuum mode after conductive coating at higher resolution. Low-vacuum SEM freeze drying technique is a simple, time-saving and reproducible method for scanning electron microscopy that is applicable to various aquatic microorganisms covered with soft tissues.

  15. In situ SEM and ToF-SIMS analysis of IgG conjugated gold nanoparticles at aqueous surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Li; Zhu, Zihua; Yu, Xiao-Ying; Rodek, Gene; Saraf, Laxmikant V.; Thevuthasan, Suntharampillai; Cowin, James P.

    2014-04-01

    In this study, we report new results of in situ study of 5 nm goat anti-mouse IgG gold nanoparticles in a novel portable vacuum compatible microfluidic device using scanning electron microscope (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The unique feature of the liquid flow cell is that the detection window is open to the vacuum allowing direct probing of the liquid surface. The flow cell is composed of a silicon nitride (SiN) membrane and polydimethylsiloxane (PDMS), and it is fully compatible with vacuum operations for surface analysis. The aperture can be drilled through the 100 nm SiN membrane using a focused ion beam. Characteristic signals of the conjugated gold nanoparticles were successfully observed through the aperture by both energy-dispersive X-ray spectroscopy (EDX) in SEM and ToF-SIMS. Comparison was also made among wet samples, dry samples, and liquid sample in the flow cell using SEM/EDX. Stronger gold signal can be observed in our novel portable device by SEM/EDX compared with the wet or dry samples, respectively. Our results indicate that analyses of the nanoparticle components are better made in their native liquid environment. This is made possible using our unique microfluidic flow cell.

  16. UV laser ablation of intraocular lenses: SEM and AFM microscopy examination of the biomaterial surface

    International Nuclear Information System (INIS)

    Spyratou, E.; Asproudis, I.; Tsoutsi, D.; Bacharis, C.; Moutsouris, K.; Makropoulou, M.; Serafetinides, A.A.

    2010-01-01

    Several new materials and patterns are studied for the formation and etching of intraocular lenses (IOLs), in order to improve their optical properties, to reduce the diffractive aberrations and to decrease the incidence of posterior capsular opacification. The aim of this study is to investigate the use of UV (λ = 266 nm) laser pulses to ablate the intraocular lenses materials, and thus to provide an alternative to conventional surface shaping techniques for IOLs fabrication. Ablation experiments were conducted using various polymer substrates of hydrophobic acrylic IOLs and PMMA IOLs. We investigated the ablation efficiency and the morphology of the ablated area by imaging the surface modification with atomic force microscopy (AFM) and scanning electron microscopy (SEM). The morphological appearance of IOL samples reveals the effect of a photochemical and photothermal ablation mechanism.

  17. UV laser ablation of intraocular lenses: SEM and AFM microscopy examination of the biomaterial surface

    Energy Technology Data Exchange (ETDEWEB)

    Spyratou, E., E-mail: ellas5@central.ntua.gr [National Technical University of Athens, School of Applied Mathematical and Physical Sciences, Department of Physics, Zografou Campus, Athens, 15780 (Greece); Asproudis, I. [Department of Ophthalmology, University Hospital of Ioannina, Ioannina, 45110 (Greece); Tsoutsi, D. [Department of Chemistry, University of Ioannina, Ioannina, 45110 (Greece); Bacharis, C.; Moutsouris, K.; Makropoulou, M.; Serafetinides, A.A. [National Technical University of Athens, School of Applied Mathematical and Physical Sciences, Department of Physics, Zografou Campus, Athens, 15780 (Greece)

    2010-02-01

    Several new materials and patterns are studied for the formation and etching of intraocular lenses (IOLs), in order to improve their optical properties, to reduce the diffractive aberrations and to decrease the incidence of posterior capsular opacification. The aim of this study is to investigate the use of UV ({lambda} = 266 nm) laser pulses to ablate the intraocular lenses materials, and thus to provide an alternative to conventional surface shaping techniques for IOLs fabrication. Ablation experiments were conducted using various polymer substrates of hydrophobic acrylic IOLs and PMMA IOLs. We investigated the ablation efficiency and the morphology of the ablated area by imaging the surface modification with atomic force microscopy (AFM) and scanning electron microscopy (SEM). The morphological appearance of IOL samples reveals the effect of a photochemical and photothermal ablation mechanism.

  18. Willis PM 10-2.5 Precision Results, pdf has summary table and SEM images

    Data.gov (United States)

    U.S. Environmental Protection Agency — Precision data from the SEM and SEM images from the samples. This dataset is associated with the following publication: Peters, T., E. Sawvel, R. Willis, R. West,...

  19. Mechatronic Development and Vision Feedback Control of a Nanorobotics Manipulation System inside SEM for Nanodevice Assembly

    Directory of Open Access Journals (Sweden)

    Zhan Yang

    2016-09-01

    Full Text Available Carbon nanotubes (CNT have been developed in recent decades for nanodevices such as nanoradios, nanogenerators, carbon nanotube field effect transistors (CNTFETs and so on, indicating that the application of CNTs for nanoscale electronics may play a key role in the development of nanotechnology. Nanorobotics manipulation systems are a promising method for nanodevice construction and assembly. For the purpose of constructing three-dimensional CNTFETs, a nanorobotics manipulation system with 16 DOFs was developed for nanomanipulation of nanometer-scale objects inside the specimen chamber of a scanning electron microscope (SEM. Nanorobotics manipulators are assembled into four units with four DOFs (X-Y-Z-θ individually. The rotational one is actuated by a picomotor. That means a manipulator has four DOFs including three linear motions in the X, Y, Z directions and a 360-degree rotational one (X-Y-Z-θ stage, θ is along the direction rotating with X or Y axis. Manipulators are actuated by picomotors with better than 30 nm linear resolution and <1 micro-rad rotary resolution. Four vertically installed AFM cantilevers (the axis of the cantilever tip is vertical to the axis of electronic beam of SEM served as the end-effectors to facilitate the real-time observation of the operations. A series of kinematic derivations of these four manipulators based on the Denavit-Hartenberg (D-H notation were established. The common working space of the end-effectors is 2.78 mm by 4.39 mm by 6 mm. The manipulation strategy and vision feedback control for multi-manipulators operating inside the SEM chamber were been discussed. Finally, application of the designed nanorobotics manipulation system by successfully testing of the pickup-and-place manipulation of an individual CNT onto four probes was described. The experimental results have shown that carbon nanotubes can be successfully picked up with this nanorobotics manipulation system.

  20. Mechatronic Development and Vision Feedback Control of a Nanorobotics Manipulation System inside SEM for Nanodevice Assembly

    Science.gov (United States)

    Yang, Zhan; Wang, Yaqiong; Yang, Bin; Li, Guanghui; Chen, Tao; Nakajima, Masahiro; Sun, Lining; Fukuda, Toshio

    2016-01-01

    Carbon nanotubes (CNT) have been developed in recent decades for nanodevices such as nanoradios, nanogenerators, carbon nanotube field effect transistors (CNTFETs) and so on, indicating that the application of CNTs for nanoscale electronics may play a key role in the development of nanotechnology. Nanorobotics manipulation systems are a promising method for nanodevice construction and assembly. For the purpose of constructing three-dimensional CNTFETs, a nanorobotics manipulation system with 16 DOFs was developed for nanomanipulation of nanometer-scale objects inside the specimen chamber of a scanning electron microscope (SEM). Nanorobotics manipulators are assembled into four units with four DOFs (X-Y-Z-θ) individually. The rotational one is actuated by a picomotor. That means a manipulator has four DOFs including three linear motions in the X, Y, Z directions and a 360-degree rotational one (X-Y-Z-θ stage, θ is along the direction rotating with X or Y axis). Manipulators are actuated by picomotors with better than 30 nm linear resolution and SEM) served as the end-effectors to facilitate the real-time observation of the operations. A series of kinematic derivations of these four manipulators based on the Denavit-Hartenberg (D-H) notation were established. The common working space of the end-effectors is 2.78 mm by 4.39 mm by 6 mm. The manipulation strategy and vision feedback control for multi-manipulators operating inside the SEM chamber were been discussed. Finally, application of the designed nanorobotics manipulation system by successfully testing of the pickup-and-place manipulation of an individual CNT onto four probes was described. The experimental results have shown that carbon nanotubes can be successfully picked up with this nanorobotics manipulation system. PMID:27649180

  1. Mechatronic Development and Vision Feedback Control of a Nanorobotics Manipulation System inside SEM for Nanodevice Assembly.

    Science.gov (United States)

    Yang, Zhan; Wang, Yaqiong; Yang, Bin; Li, Guanghui; Chen, Tao; Nakajima, Masahiro; Sun, Lining; Fukuda, Toshio

    2016-09-14

    Carbon nanotubes (CNT) have been developed in recent decades for nanodevices such as nanoradios, nanogenerators, carbon nanotube field effect transistors (CNTFETs) and so on, indicating that the application of CNTs for nanoscale electronics may play a key role in the development of nanotechnology. Nanorobotics manipulation systems are a promising method for nanodevice construction and assembly. For the purpose of constructing three-dimensional CNTFETs, a nanorobotics manipulation system with 16 DOFs was developed for nanomanipulation of nanometer-scale objects inside the specimen chamber of a scanning electron microscope (SEM). Nanorobotics manipulators are assembled into four units with four DOFs (X-Y-Z-θ) individually. The rotational one is actuated by a picomotor. That means a manipulator has four DOFs including three linear motions in the X, Y, Z directions and a 360-degree rotational one (X-Y-Z-θ stage, θ is along the direction rotating with X or Y axis). Manipulators are actuated by picomotors with better than 30 nm linear resolution and <1 micro-rad rotary resolution. Four vertically installed AFM cantilevers (the axis of the cantilever tip is vertical to the axis of electronic beam of SEM) served as the end-effectors to facilitate the real-time observation of the operations. A series of kinematic derivations of these four manipulators based on the Denavit-Hartenberg (D-H) notation were established. The common working space of the end-effectors is 2.78 mm by 4.39 mm by 6 mm. The manipulation strategy and vision feedback control for multi-manipulators operating inside the SEM chamber were been discussed. Finally, application of the designed nanorobotics manipulation system by successfully testing of the pickup-and-place manipulation of an individual CNT onto four probes was described. The experimental results have shown that carbon nanotubes can be successfully picked up with this nanorobotics manipulation system.

  2. Revealing Rembrandt

    Directory of Open Access Journals (Sweden)

    Andrew J Parker

    2014-04-01

    Full Text Available The power and significance of artwork in shaping human cognition is self-evident. The starting point for our empirical investigations is the view that the task of neuroscience is to integrate itself with other forms of knowledge, rather than to seek to supplant them. In our recent work, we examined a particular aspect of the appreciation of artwork using present-day functional magnetic resonance imaging (fMRI. Our results emphasised the continuity between viewing artwork and other human cognitive activities. We also showed that appreciation of a particular aspect of artwork, namely authenticity, depends upon the co-ordinated activity between the brain regions involved in multiple decision making and those responsible for processing visual information. The findings about brain function probably have no specific consequences for understanding how people respond to the art of Rembrandt in comparison with their response to other artworks. However, the use of images of Rembrandt’s portraits, his most intimate and personal works, clearly had a significant impact upon our viewers, even though they have been spatially confined to the interior of an MRI scanner at the time of viewing. Neuroscientific studies of humans viewing artwork have the capacity to reveal the diversity of human cognitive responses that may be induced by external advice or context as people view artwork in a variety of frameworks and settings.

  3. Modelo de web semántica para universidades

    Directory of Open Access Journals (Sweden)

    Karla Abad

    2015-12-01

    Full Text Available A raíz del estudio de estado actual de micrositios y repositorios en la Universidad Estatal Península de Santa Elena se encontró que su información carecía de semántica óptima y adecuada. Bajo estas circunstancias, se plantea entonces la necesidad de crear un modelo de estructura de web semántica para Universidades, el cual posteriormente fue aplicado a micrositios y repositorio digital de la UPSE, como caso de prueba. Parte de este proyecto incluye la instalación de módulos de software con sus respectivas configuraciones y la utilización de estándares de metadatos como DUBLIN CORE, para la mejora del SEO (optimización en motores de búsqueda; con ello se ha logrado la generación de metadatos estandarizados y la creación de políticas para la subida de información. El uso de metadatos transforma datos simples en estructuras bien organizadas que aportan información y conocimiento para generar resultados en buscadores web. Al culminar la implementación del modelo de web semántica es posible decir que la universidad ha mejorado su presencia y visibilidad en la web a través del indexamiento de información en diferentes motores de búsqueda y posicionamiento en la categorización de universidades y de repositorios de Webometrics (ranking que proporciona clasificación de universidades de todo el mundo.   Abstract After examining the current microsites and repositories situation in University, Peninsula of Santa Elena´s, it was found that information lacked optimal and appropriate semantic. Under these circumstances, there is a need to create a semantic web structure model for Universities, which was subsequently applied to UPSE´s microsites and digital repositories, as a test study case. Part of this project includes the installation of software modules with their respective configurations and the use of metadata standards such as DUBLIN CORE, to improve the SEO (Search Engine Optimization; with these applications, it was

  4. Multiple-Group Analysis Using the sem Package in the R System

    Science.gov (United States)

    Evermann, Joerg

    2010-01-01

    Multiple-group analysis in covariance-based structural equation modeling (SEM) is an important technique to ensure the invariance of latent construct measurements and the validity of theoretical models across different subpopulations. However, not all SEM software packages provide multiple-group analysis capabilities. The sem package for the R…

  5. A combined technique using SEM and TOPSIS for the commercialization capability of R&D project evaluation

    Directory of Open Access Journals (Sweden)

    Charttirot Karaveg

    2015-07-01

    Full Text Available There is a high risk of R&D based innovation being commercialized, especially in the innovation transfer process which is a concern to many entrepreneurs and researchers. The purpose of this research is to develop the criteria of R&D commercialization capability and to propose a combined technique of Structural Equation Modelling (SEM and Technique for Order Preference by Similarity to Ideal Solution (TOPSIS for R&D project evaluation. The research utilized a mixed-method approach. The first phase comprised a qualitative study on commercialization criteria development though the survey research of 272 successful entrepreneurs and researchers in all industrial sectors in Thailand. The data was collected with a structured questionnaire and analyzed by SEM. The second phase was involved with SEM-TOPSIS technique development and a case study of 45 R&D projects in research institutes and incubators for technique validation. The research results reveal that there were six criteria for R&D project commercialization capability, these are arranged according to the significance; marketing, technology, finance, non-financial impact, intellectual property, and human resource. The holistic criteria is presented in decreasing order on the ambiguous subjectivity of the fuzzy-expert system, to help with effectively funding R&D and to prevent a resource meltdown. This study applies SEM to the relative weighting of hierarchical criteria. The TOPSIS approach is employed to rank the alternative performance. An integrated SEM-TOPSIS is proposed for the first time and applied to present R&D projects shown to be effective and feasible in evaluating R&D commercialization capacity.

  6. SEM Characterization of Extinguished Grains from Plasma-Ignited M30 Charges

    Science.gov (United States)

    Kinkennon, A.; Birk, A.; DelGuercio, M.; Kaste, P.; Lieb, R.; Newberry, J.; Pesce-Rodriguez, R.; Schroeder, M.

    2000-01-01

    M30 propellant grains that had been ignited in interrupted closed bomb experiments were characterize by scanning electron microscopy (SEM). Previous chemical analysis of extinguished grains had given no indications of plasma-propellant chemical interactions that could explain the increased burning rates that had been previously observed in full-pressure closed bomb experiments. (This does not mean that there is no unique chemistry occurring with plasma ignition. It may occur very early in the ignition event and then become obscured by the burning chemistry.) In this work, SEM was used to look at grain morphologies to determine if there were increases in the surface areas of the plasma-ignited grains which would contribute to the apparent increase in the burning rate. Charges were made using 30 propellant grains (approximately 32 grams) stacked in two tiers and in two concentric circles around a plastic straw. Each grain was notched so that, when the grains were expelled from the bomb during extinguishment, it could be determined in which tier and which circle each grain was originally packed. Charges were ignited in a closed bomb by either a nickel wire/Mylar-capillary plasma or black powder. The bomb contained a blowout disk that ruptured when the pressure reached 35 MPa, and the propellant was vented into a collection chamber packed with polyurethane foam. SEM analysis of the grains fired with a conventional black powder igniter showed no signs of unusual burning characteristics. The surfaces seemed to be evenly burned on the exteriors of the grains and in the perforations. Grains that had been subjected to plasma ignition, however, had pits, gouges, chasms, and cracks in the surfaces. The sides of the grains closest to the plasma had the greatest amount of damage, but even surfaces facing the outer wall of the bomb had small pits. The perforations contained gouges and abnormally burned regions (wormholes) that extended into the web. The SEM photos indicated that

  7. Validation of cell-free culture using scanning electron microscopy (SEM) and gene expression studies.

    Science.gov (United States)

    Yang, R; Elankumaran, Y; Hijjawi, N; Ryan, U

    2015-06-01

    A cell-free culture system for Cryptosporidium parvum was analysed using scanning electron microscopy (SEM) to characterise life cycle stages and compare gene expression in cell-free culture and cell culture using HCT-8 cells. Cryptosporidium parvum samples were harvested at 2 h, 8 h, 14 h, 26 h, 50 h, 74 h, 98 h, 122 h and 170 h, chemically fixed and specimens were observed using a Zeiss 1555 scanning electron microscope. The presence of sporozoites, trophozoites and type I merozoites were identified by SEM. Gene expression in cell culture and cell-free culture was studied using reverse transcriptase quantitative PCR (RT-qPCR) of the sporozoite surface antigen protein (cp15), the glycoprotein 900 (gp900), the Cryptosporidium oocyst wall protein (COWP) and 18S ribosomal RNA (rRNA) genes in both cell free and conventional cell culture. In cell culture, cp15 expression peaked at 74 h, gp900 expression peaked at 74 h and 98 h and COWP expression peaked at 50 h. In cell-free culture, CP15 expression peaked at 98 h, gp900 expression peaked at 74 h and COWP expression peaked at 122 h. The present study is the first to compare gene expression of C. parvum in cell culture and cell-free culture and to characterise life cycle stages of C. parvum in cell-free culture using SEM. Findings from this study showed that gene expression patterns in cell culture and cell-free culture were similar but in cell-free culture, gene expression was delayed for CP15 and COWP in cell free culture compared with the cell culture system and was lower. Although three life cycle stageswere conclusively identified, improvements in SEM methodology should lead to the detection of more life cycle stages. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Sexual Arousal and Sexually Explicit Media (SEM: Comparing Patterns of Sexual Arousal to SEM and Sexual Self-Evaluations and Satisfaction Across Gender and Sexual Orientation

    Directory of Open Access Journals (Sweden)

    Gert Martin Hald, PhD

    2018-03-01

    Hald GM, Stulhofer A, Lange T, et al. Sexual Arousal and Sexually Explicit Media (SEM: Comparing Patterns of Sexual Arousal to SEM and Sexual Self-Evaluations and Satisfaction Across Gender and Sexual Orientation. Sex Med 2018;6:30–38.

  9. Quality control of clinker products by SEM and XRF analysis

    International Nuclear Information System (INIS)

    Ziad Abu Kaddourah; Khairun Azizi

    1996-01-01

    The microstructure and chemical properties of industrial Portland cement clinkers have been examined by SEM and XRF methods to establish the nature of the clinkers and how variations in the clinker characteristics can be used to control the clinker quality. The clinker nodules were found to show differences in the chemical composition and microstructure between the inner and outer parts of the clinker nodules. Microstructure studies of industrial Portland cement clinker have shown that the outer part of the nodules are enriched in silicate more than the inner part. There is better crystallization and larger alite crystal size in the outer part than in the inner part. The alite crystal size varied between 16.2 -46.12 μ m. The clinker chemical composition was found to affect the residual >45 μ m, where a higher belite content causes an increase in the residual >45 μ m in the the cement product and will cause a decrease in the concrete strength of the cement product. The aluminate and ferrite crystals and the microcracks within the alite crystal are clear in some clinker only. The quality of the raw material preparation, burning and cooling stages can be controlled using the microstructure of the clinker product

  10. Semáforo de habilidad digital para estudiantes universitarios

    Directory of Open Access Journals (Sweden)

    Javier Organista Sandoval

    2017-01-01

    Full Text Available El vertiginoso cambio tecnológico y el creciente uso de dispositivos portátiles en el entorno educativo universitario han propiciado una carga importante de mediación tecnológica del proceso educativo. Ante este contexto, el reto es lograr que los estudiantes aprovechen el potencial pedagógico que ofrecen estas herramientas. Para ello, el estudiante debe contar con las habilidades digitales para utilizar eficientemente las tecnologías digitales. Se parte de la identificación de las habilidades en torno al manejo de comunicación, información, organización y dispositivos con una orientación educativa. Los resultados mostraron que 68% de los estudiantes tienen un nivel aceptable de habilidad digital, 25% regular y un 7% insuficiente. El instrumento utilizado identifica las habilidades digitales que requieren mejorarse y se muestran mediante una señalización similar a la de un semáforo. En la medida en que se identifiquen las habilidades digitales que se requieran mejorar, se espera que la comunidad académica se apropie y aplique la tecnología digital en la educación, de cara a los desafíos de la formación de recursos humanos que la sociedad actual demanda.

  11. SEM Based CARMA Time Series Modeling for Arbitrary N.

    Science.gov (United States)

    Oud, Johan H L; Voelkle, Manuel C; Driver, Charles C

    2018-01-01

    This article explains in detail the state space specification and estimation of first and higher-order autoregressive moving-average models in continuous time (CARMA) in an extended structural equation modeling (SEM) context for N = 1 as well as N > 1. To illustrate the approach, simulations will be presented in which a single panel model (T = 41 time points) is estimated for a sample of N = 1,000 individuals as well as for samples of N = 100 and N = 50 individuals, followed by estimating 100 separate models for each of the one-hundred N = 1 cases in the N = 100 sample. Furthermore, we will demonstrate how to test the difference between the full panel model and each N = 1 model by means of a subject-group-reproducibility test. Finally, the proposed analyses will be applied in an empirical example, in which the relationships between mood at work and mood at home are studied in a sample of N = 55 women. All analyses are carried out by ctsem, an R-package for continuous time modeling, interfacing to OpenMx.

  12. Automated SEM Modal Analysis Applied to the Diogenites

    Science.gov (United States)

    Bowman, L. E.; Spilde, M. N.; Papike, James J.

    1996-01-01

    Analysis of volume proportions of minerals, or modal analysis, is routinely accomplished by point counting on an optical microscope, but the process, particularly on brecciated samples such as the diogenite meteorites, is tedious and prone to error by misidentification of very small fragments, which may make up a significant volume of the sample. Precise volume percentage data can be gathered on a scanning electron microscope (SEM) utilizing digital imaging and an energy dispersive spectrometer (EDS). This form of automated phase analysis reduces error, and at the same time provides more information than could be gathered using simple point counting alone, such as particle morphology statistics and chemical analyses. We have previously studied major, minor, and trace-element chemistry of orthopyroxene from a suite of diogenites. This abstract describes the method applied to determine the modes on this same suite of meteorites and the results of that research. The modal abundances thus determined add additional information on the petrogenesis of the diogenites. In addition, low-abundance phases such as spinels were located for further analysis by this method.

  13. The Effect of Different Cleaning Protocols on Post Space: A SEM Study

    Directory of Open Access Journals (Sweden)

    Giuseppe Lo Giudice

    2016-01-01

    Full Text Available Aim. Purpose of the present paper is to analyze the efficiency of different post-space irrigation protocols. Methods. 28 single rooted teeth were endodontically treated. After post-space preparation every sample was assigned to one of three experimental groups and to one control group. In each group different irrigation protocols were performed as follows: EDTA (Group A, 37% orthophosphoric acid (Group B, and EDTA + 37% orthophosphoric acid with ultrasounds activation (Group C. In the control group (Group D the irrigate association was not activated by ultrasounds. Three zones (coronal, middle, and apical of each sample were analyzed by using Scan Electron Microscopy (SEM without any metallization procedures. The presence of smear layer on the canal surface was qualitatively evaluated by applying Serafino’s score with values included between 0 and 2. Results. The results of the research showed how Group C recorded the better results (0.81±0.72. Group A and Group B showed lower mean scores (1.06±0.69 and 1.08±0.77; Group D showed the lowest mean score of 1.30±0.69. The SEM observation analysis demonstrated how the smear layer presence decreased in the crown-apical direction. Conclusions. The different post-space treatments statistically determine significant differences on the dentinal surfaces cleansing. The absence of ultrasonic activation lowers the cleansing efficacy of endocanalar irrigants, showing sensible differences among each post-space zone.

  14. Marginal adaptation of newer root canal sealers to dentin: A SEM study.

    Science.gov (United States)

    Polineni, Swapnika; Bolla, Nagesh; Mandava, Pragna; Vemuri, Sayesh; Mallela, Madhusudana; Gandham, Vijaya Madhuri

    2016-01-01

    This in vitro study evaluated and compared the marginal adaptation of three newer root canal sealers to root dentin. Thirty freshly extracted human single-rooted teeth with completely formed apices were taken. Teeth were decoronated, and root canals were instrumented. The specimens were randomly divided into three groups (n = 10) based upon the sealer used. Group 1 - teeth were obturated with epoxy resin sealer (MM-Seal). Group 2 - teeth were obturated with mineral trioxide aggregate (MTA) based sealer (MTA Fillapex), Group 3 - teeth were obturated with bioceramic sealer (EndoSequence BC sealer). Later samples were vertically sectioned using hard tissue microtome and marginal adaptation of sealers to root dentin was evaluated under coronal and apical halves using scanning electron microscopy (SEM) and marginal gap values were recorded. The data were statistically analyzed by two-way ANOVA and Tukey's multiple post hoc test. The highest marginal gap was seen in Group 2 (apical-16680.00 nm, coronal-10796 nm) and the lowest marginal gap was observed in Group 1 (apical-599.42 nm, coronal-522.72 nm). Coronal halves showed superior adaptation compared to apical halves in all the groups under SEM. Within the limitations of this study epoxy resin-based MM-Seal showed good marginal adaptation than other materials tested.

  15. Morphological, chemical and structural characterisation of deciduous enamel: SEM, EDS, XRD, FTIR and XPS analysis.

    Science.gov (United States)

    Zamudio-Ortega, C M; Contreras-Bulnes, R; Scougall-Vilchis, R J; Morales-Luckie, R A; Olea-Mejía, O F; Rodríguez-Vilchis, L E

    2014-09-01

    The purpose of this study was to characterise the enamel surface of sound deciduous teeth in terms of morphology, chemical composition, structure and crystalline phases. The enamel of 30 human deciduous teeth was examined by: Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray Spectroscopy (EDS), X-ray Powder Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR), and X-ray Photoelectron Spectroscopy (XPS). Chemical differences between incisors and canines were statistically evaluated using the Mann-Whitney U test (p ≤ 0.05). Three enamel patterns were observed by SEM: 'mostly smooth with some groves', 'abundant microporosities' and 'exposed prisms'. The average Ca/P molar ratios were 1.37 and 1.03 by EDS and XPS, respectively. The crystallite size determined by XRD was 210.82 ± 16.78 Å. The mean ratio between Ca bonded to phosphate and Ca bonded to hydroxyl was approximately 10:1. The enamel of sound deciduous teeth showed two main patterns: 'mostly smooth with some groves' and 'abundant microporosities'. 'Exposed prisms' was a secondary pattern. There were slight variations among the Ca/P molar ratios found by EDS and XPS, suggesting differences in the mineral content from the enamel surface to the interior. The crystalline phases found in enamel were hydroxyapatite and carbonate apatite, with major type B than type A carbonate incorporation.

  16. Charging effects of PET under electron beam irradiation in a SEM

    International Nuclear Information System (INIS)

    Jbara, O; Rondot, S; Hadjadj, A; Patat, J M; Fakhfakh, S; Belhaj, M

    2008-01-01

    This paper deals with charge trapping and charge transport of polyethylene terephthalate (PET) polymer subjected to electron irradiation in a scanning electron microscope (SEM). Measurement of displacement current and leakage current using an arrangement adapted to the SEM allows the amount of trapped charge during and after electron irradiation to be determined and the charge mechanisms regulation to be studied. These mechanisms involve several parameters related to the electronic injection, the characteristics of insulator and the effects of the trapped charge itself. The dynamic trapping properties of PET samples are investigated and the time constants of charging are evaluated for various conditions of irradiation. The determination of the trapping cross section for electrons is possible by using the trapping rate at the onset of irradiation. Many physical processes are involved in the charging and discharging mechanisms; among them surface conduction is outlined. Through the control of irradiation conditions, various types of surface discharging (flashover phenomenon) behaviour are also observed. The strength of the electric field initiating surface discharge is estimated.

  17. Tratamento da forma mucosa de leishmaniose sem resposta a glucantime, com anfotericina B liposomal

    Directory of Open Access Journals (Sweden)

    Raimunda Nonata Ribeiro Sampaio

    1997-04-01

    Full Text Available Tratamos com ambisome (2 a 5g totais de dose seis pacientes com leishmaniose mucosa sem resposta a tratamento com glucantime (20mg SbV/kg/dia. A dose diária usada foi 2 a 3mg/kg/dia, aplicada por um mínimo de 20 dias. Após 26 a 38 meses de acompanhamento, cinco pacientes estão clinicamente curados. Um recidivou aos 6 meses. Não foram observados efeitos colaterais além de cefaléia, após a injeção. O ambisome constitue uma opção terapêutica para os pacientes com leishmaniose mucosa sem resposta aos antimoniais.We treated six patients with mucosal leishmaniasis who failed to respond to glucantime (20mg/kg/day with ambisome (2-5 grams total dose. The daily dose was 2-3mg/kg/day given for a minimum of 20 days. After 26-38 months of follow up, five patients were clinically cured. One relapsed after six months. No side effects of therapy were observed apart from headache after injection. Ambisome is a therapeutic option for patients with mucosal leishmaniasis unresponsive to antimonials.

  18. Protective effects of a zinc-hydroxyapatite toothpaste on enamel erosion: SEM study.

    Science.gov (United States)

    Colombo, Marco; Beltrami, Riccardo; Rattalino, Davide; Mirando, Maria; Chiesa, Marco; Poggio, Claudio

    2016-01-01

    The aim of the present in vitro study was to evaluate the protective effects of a zinc-hydroxyapatite toothpaste against an erosive challenge produced by a soft drink (Coca-Cola) using Scanning Electron Microscopy (SEM). Forty specimens were assigned to 4 groups of 10 specimens each (group 1: no erosive challenge, no toothpaste treatment, group 2: erosive challenge, no toothpaste treatment, group 3: erosive challenge, fluoride toothpaste treatment, group 4: erosive challenge, zinc-hydroxyapatite toothpaste treatment). The surface of each specimen was imaged by SEM. A visual rating system was used to evaluate the condition of the enamel surface; results were analyzed by nonparametric statistical methods. Statistically significant differences were found between the samples untreated and those immersed in Coca-Cola (group 1, 2); the highest grade of damage was found in group 2, while the lowest grade was recorded in the samples of group 4. Comparing the groups, the two analyzed toothpaste tended to protect in different extend. In this study treatment of erosively challenged enamel with Zn-Hap toothpaste showed a clear protective effect. This was greater than the effect observed for a normal fluoride toothpaste and confirmed the potential benefit the Zn-HAP technology can provide in protecting enamel from erosive acid challenges.

  19. Simulation of FIB-SEM images for analysis of porous microstructures.

    Science.gov (United States)

    Prill, Torben; Schladitz, Katja

    2013-01-01

    Focused ion beam nanotomography-scanning electron microscopy tomography yields high-quality three-dimensional images of materials microstructures at the nanometer scale combining serial sectioning using a focused ion beam with SEM. However, FIB-SEM tomography of highly porous media leads to shine-through artifacts preventing automatic segmentation of the solid component. We simulate the SEM process in order to generate synthetic FIB-SEM image data for developing and validating segmentation methods. Monte-Carlo techniques yield accurate results, but are too slow for the simulation of FIB-SEM tomography requiring hundreds of SEM images for one dataset alone. Nevertheless, a quasi-analytic description of the specimen and various acceleration techniques, including a track compression algorithm and an acceleration for the simulation of secondary electrons, cut down the computing time by orders of magnitude, allowing for the first time to simulate FIB-SEM tomography. © Wiley Periodicals, Inc.

  20. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM

    International Nuclear Information System (INIS)

    Bok, Jan; Lalinský, Ondřej; Hanuš, Martin; Onderišinová, Zuzana; Kelar, Jakub; Kučera, Miroslav

    2016-01-01

    Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications. - Highlights: • First practical application of epitaxial garnet films demonstrated in SEM. • Improved image quality of SEM equipped with GAGG:Ce single crystalline thin film scintillator. • Scintillation properties of GAGG:Ce films compared with standard bulk crystal scintillators.

  1. Observing participating observation

    DEFF Research Database (Denmark)

    Keiding, Tina Bering

    2011-01-01

    Current methodology concerning participating observation in general leaves the act of observation unobserved. Approaching participating observation from systems theory offers fundamental new insights into the topic. Observation is always participation. There is no way to escape becoming...

  2. Observing participating observation

    DEFF Research Database (Denmark)

    Keiding, Tina Bering

    2010-01-01

    Current methodology concerning participating observation in general leaves the act of observation unobserved. Approaching participating observation from systems theory offers fundamental new insights into the topic. Observation is always participation. There is no way to escape becoming...

  3. Prolongamentos na fala de adultos com e sem gagueira

    Directory of Open Access Journals (Sweden)

    Pâmila Bento da Silva

    Full Text Available RESUMO Objetivo: realizar uma análise quantitativa e qualitativa dos prolongamentos de adultos com e sem gagueira. Métodos: os participantes foram divididos em: Grupo de Pesquisa (GP, 15 adultos com gagueira e Grupo Controle (GC, 15 fluentes. Os procedimentos utilizados foram: avaliação da fluência, Instrumento de Gravidade da Gagueira e análises quantitativa e qualitativa dos prolongamentos. Resultados: GP mostrou maior número de prolongamentos não hesitativos, enquanto que GC mostrou maior ocorrência de prolongamentos hesitativos em relação ao total das disfluências. Prolongamentos não hesitativos ocorreram com maior frequência na palavra inicial e monossilábica, bem como na posição medial da frase para GP. Em relação à tensão muscular e duração, observou-se diferença apenas para a tensão muscular nos prolongamentos não hesitativos com maior média de ocorrência para GP. Conclusão: os prolongamentos não hesitativos ocorreram com maior frequência no GP, nas palavras iniciais, monossílabos e na posição medial da frase. Qualitativamente a tensão muscular foi uma característica típica dos prolongamentos não hesitativos no GP. Com relação aos prolongamentos hesitativos houve semelhança entre os adultos dos dois grupos quanto à frequência em relação ao total da fala, a posição dos prolongamentos nas palavras e nas frases e nos aspectos qualitativos, relacionados a tensão muscular e duração.

  4. Influence of glass particle size of resin cements on bonding to glass ceramic: SEM and bond strength evaluation.

    Science.gov (United States)

    Valentini, Fernanda; Moraes, Rafael R; Pereira-Cenci, Tatiana; Boscato, Noéli

    2014-05-01

    This study investigated the effect of the filler particle size (micron or submicron) of experimental resin cements on the microtensile bond strength to a glass-ceramic pretreated with hydrofluoric acid (HFA) etching or alumina airborne-particle abrasion (AA). Cements were obtained from a Bis-GMA/TEGDMA mixture filled with 60 mass% micron-sized (1 ± 0.2 µm) or submicron-sized (180 ± 30 µm) Ba-Si-Al glass particles. Ceramic blocks (PM9; VITA) were treated with 10% HFA for 60 s or AA for 15 s. Silane and adhesive were applied. Ceramic blocks were bonded to resin composite blocks (Z250; 3M ESPE) using one of the cements. Bonded specimens were sectioned into beams (n = 20/group) and subjected to microtensile bond strength tests. Data were analyzed using ANOVA and Student-Newman-Keuls' tests (5%). Failure modes were classified under magnification. Morphologies of the treated ceramic surfaces and bonded interfaces were evaluated by scanning electron microscopy. The HFA-submicron group had lower bond strengths than the other groups. All AA-submicron specimens debonded prematurely. Mixed failures were predominant for HFA groups, whereas interfacial failures predominated for AA groups. SEM revealed a honeycomb-like aspect in the HFA-treated ceramic, whereas the AA-treated groups showed an irregular retentive pattern. Continuity of cement infiltration along the bonded interface was more uniform for HFA-treated compared to AA-treated specimens. Cracks toward the bulk of the ceramic were observed in AA-treated specimens. Particle size significantly influenced the ceramic bond strength, whereas surface treatment had a minor effect. Copyright © 2014 Wiley Periodicals, Inc.

  5. Evaluating Neighborhoods Livability in Nigeria: A Structural Equation Modelling (SEM Approach

    Directory of Open Access Journals (Sweden)

    Sule Abass Iyanda

    2018-01-01

    Full Text Available There is a growing concern about city livability around the world and of particular concern is the aspects of the person-environment relationship which encompasses many characteristics suffice to make a place livable. Extant literature provides livability dimensions such as housing unit characteristics, neighborhood facilities, economic vitality and safety environment. These livability dimensions as well as their attributes found in the extant literature have been reported to have high reliability measurement level. Although, various methods have been applied to examine relationships among the variables however structural equation modeling (SEM has been found more holistic as a modeling technique to understand and explain the relationships that may exist among variable measurements. Structural equation modeling simultaneously performs multivariate analysis including multiple regression, path and factor analysis in the cause-effect relationships between latent constructs. Therefore, this study investigates the key factors of livability of planned residential neighborhoods in Minna, Nigeria with the research objectives of – (a to study the livability level of the selected residential neighborhoods, (b to determine the dimensions and indicators which most influence the level of livability in the selected residential neighborhoods, and (c to reliably test the efficacy of structural equation modeling (SEM in the assessment of livability. The methodology adopted in this study includes- Data collection with the aid of structured questionnaire survey administered to the residents of the study area based on stratified random sampling. The data collected was analyzed with the aid of the Statistical Package for Social Sciences (SPSS 22.0 and AMOS 22.0 software for structural equation modeling (a second-order factor. The study revealed that livability as a second-order factor is indicated by economic vitality, safety environment, neighborhood facilities

  6. Surface morphology of Nicolla skrjabini (Trematoda: Opecoelidae), a common parasite of European freshwater fishes, as revealed by SEM

    Czech Academy of Sciences Publication Activity Database

    Moravec, František

    2009-01-01

    Roč. 105, č. 2 (2009), s. 577-578 ISSN 0932-0113 R&D Projects: GA MŠk LC522 Institutional research plan: CEZ:AV0Z60220518 Keywords : surface ultrastructure * Nicolla * Czech Republic Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 1.721, year: 2009

  7. External morphological differences between Crepidostomum farionis and Crepidostomum metoecus (Trematoda: Allocreadiidae), parasites of salmonids, as revealed by SEM

    Czech Academy of Sciences Publication Activity Database

    Moravec, František

    2002-01-01

    Roč. 49, č. 3 (2002), s. 211-217 ISSN 0015-5683 R&D Projects: GA ČR GA524/00/0267 Institutional research plan: CEZ:AV0Z6022909 Keywords : Trematoda * Crepidostomum * surface morphology Subject RIV: EG - Zoology Impact factor: 0.515, year: 2002

  8. Electron tomography and cryo-SEM characterization reveals novel ultrastructural features of host-parasite interaction during Chlamydia abortus infection.

    Science.gov (United States)

    Wilkat, M; Herdoiza, E; Forsbach-Birk, V; Walther, P; Essig, A

    2014-08-01

    Chlamydia (C.) abortus is a widely spread pathogen among ruminants that can be transmitted to women during pregnancy leading to severe systemic infection with consecutive abortion. As a member of the Chlamydiaceae, C. abortus shares the characteristic feature of an obligate intracellular biphasic developmental cycle with two morphological forms including elementary bodies (EBs) and reticulate bodies (RBs). In contrast to other chlamydial species, C. abortus ultrastructure has not been investigated yet. To do so, samples were fixed by high-pressure freezing and processed by different electron microscopic methods. Freeze-substituted samples were analysed by transmission electron microscopy, scanning transmission electron microscopical tomography and immuno-electron microscopy, and freeze-fractured samples were analysed by cryo-scanning electron microscopy. Here, we present three ultrastructural features of C. abortus that have not been reported up to now. Firstly, the morphological evidence that C. abortus is equipped with the type three secretion system. Secondly, the accumulation and even coating of whole inclusion bodies by membrane complexes consisting of multiple closely adjacent membranes which seems to be a C. abortus specific feature. Thirdly, the formation of small vesicles in the periplasmic space of RBs in the second half of the developmental cycle. Concerning the time point of their formation and the fact that they harbour chlamydial components, these vesicles might be morphological correlates of an intermediate step during the process of redifferentiation of RBs into EBs. As this feature has also been shown for C. trachomatis and C. pneumoniae, it might be a common characteristic of the family of Chlamydiaceae.

  9. Structure of the female cephalic end and cuticular ornamentations of Paraphilometroides nemipteri (Nematoda: Philometridae), as revealed by SEM

    Czech Academy of Sciences Publication Activity Database

    Moravec, František

    2010-01-01

    Roč. 57, č. 4 (2010), s. 313-314 ISSN 0015-5683 R&D Projects: GA MŠk LC522 Institutional research plan: CEZ:AV0Z60220518 Keywords : Paraphilometroides * Nemipterus * Malaysia Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 1.533, year: 2010

  10. Enhanced defect of interest [DOI] monitoring by utilizing sensitive inspection and ADRTrue SEM review

    Science.gov (United States)

    Kirsch, Remo; Zeiske, Ulrich; Shabtay, Saar; Beyer, Mirko; Yerushalmi, Liran; Goshen, Oren

    2011-03-01

    As semiconductor process design rules continue to shrink, the ability of optical inspection tools to separate between true defects and nuisance becomes more and more difficult. Therefore, monitoring Defect of Interest (DOI) become a real challenge (Figure 1). This phenomenon occurs due to the lower signal received from real defects while noise levels remain almost the same, resulting in inspection high nuisance rate, which jeopardizes the ability to provide a meaningful, true defect Pareto. A non-representative defect Pareto creates a real challenge to a reliable process monitoring (Figure 4). Traditionally, inspection tool recipes were optimized to keep data load at a manageable level and provide defect maps with ~10% nuisance rate, but as defects of interest get smaller with design rule shrinkage, this requirement results in a painful compromise in detection sensitivity. The inspection is usually followed by defect review and classification using scanning electron microscope (SEM), the classification done manually and it is performed on a small sample of the inspection defect map due to time and manual resources limitations. Sample is usually 50~60 randomly selected locations, review is performed manually most of the times, and manual classification is performed for all the reviewed locations. In the approach described in this paper, the inspection tool recipe is optimized for sensitivity rather than low nuisance rate (i.e. detect all DOI with compromising on a higher nuisance rate). Inspection results with high nuisance rate introduce new challenges for SEM review methodology & tools. This paper describe a new approach which enhances process monitoring quality and the results of collaborative work of the Process Diagnostic & Control Business Unit of Applied Materials® and GLOBALFOUNDRIES® utilizing Applied Materials ADRTrueTM & SEMVisionTM capabilities. The study shows that the new approach reveals new defect types in the Pareto, and improves the ability to

  11. Tracking calcification in tissue-engineered bone using synchrotron micro-FTIR and SEM.

    Science.gov (United States)

    Deegan, Anthony J; Cinque, Gianfelice; Wehbe, Katia; Konduru, Sandeep; Yang, Ying

    2015-02-01

    One novel tissue engineering approach to mimic in vivo bone formation is the use of aggregate or micromass cultures. Various qualitative and quantitative techniques, such as histochemical staining, protein assay kits and RT-PCR, have been used previously on cellular aggregate studies to investigate how these intricate arrangements lead to mature bone tissue. However, these techniques struggle to reveal spatial and temporal distribution of proliferation and mineralization simultaneously. Synchrotron-based Fourier transform infrared microspectroscopy (micro-FTIR) offers a unique insight at the molecular scale by coupling high IR sensitivity to organic matter with the high spatial resolution allowed by diffraction limited SR microbeam. This study is set to investigate the effects of culture duration and aggregate size on the dynamics and spatial distribution of calcification in engineered bone aggregates by a combination of micro-FTIR and scanning electron microscopy (SEM)/energy-dispersive X-ray spectroscopy (EDX). A murine bone cell line has been used, and small/large bone aggregates have been induced using different chemically treated culture substrates. Our findings suggest that bone cell aggregate culturing can greatly increase levels of mineralization over short culture periods. The size of the aggregates influences mineralisation rates with larger aggregates mineralizing at a faster rate than their smaller counterparts. The micro-FTIR mapping has demonstrated that mineralization in the larger aggregates initiated from the periphery and spread to the centre, whilst the smaller aggregates have more minerals in the centre at the early stage and deposited more in the periphery after further culturing, implying that aggregate size influences calcification distribution and development over time. SEM/EDX data correlates well with the micro-FTIR results for the total mineral content. Thus, synchrotron-based micro-FTIR can accurately track mineralization process

  12. XRD, SEM and infrared study into the intercalation of sodium hexadecyl sulfate (SHS) into hydrocalumite.

    Science.gov (United States)

    Zhang, Ping; Wang, Tianqi; Zhang, Longlong; Wu, Daishe; Frost, Ray L

    2015-12-05

    Hydrocalumite (CaAl-LDH-Cl) interacted with a natural anionic surfactant, sodium hexadecyl sulfate (SHS), was performed using an intercalation method. To understand the intercalation behavior and characterize the resulting products, powder X-ray diffraction (XRD), scan electron microscopy (SEM) and mid-infrared (MIR) spectroscopy combined with near-infrared (NIR) spectroscopy technique were used. The XRD analysis indicated that SHS was intercalated into CaAl-LDH-Cl successfully, resulting in an expansion of the interlayer (from 0.78 nm to 2.74 nm). The bands of C-H stretching vibrations of SHS were observed in the near-infrared spectra, which indicated that the resulting products were indeed CaAl-LDH-SHS. In addition, the bands of water stretching vibrations and OH groups shifted to higher wavenumbers when SHS was intercalated into CaAl-LDH-Cl interlayer space. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. FIB/SEM study of AA2024 corrosion under a seawater drop, part II

    International Nuclear Information System (INIS)

    King, Peter C.; Cole, Ivan S.; Corrigan, Penny A.; Hughes, Anthony E.; Muster, Tim H.; Thomas, Sebastian

    2012-01-01

    Highlights: ► Dealloying has a directional nature, exhibits banding. ► Oxidation state of copper in sponge remnants found to be variable. ► Dissolution and breakdown of copper sponge structure observed. ► Crystalline defects imaged in dealloyed S-phase. - Abstract: The dissolution of S-phase clusters in aluminium alloy 2024 (AA2024) exposed to a 0.5 μl seawater droplet is presented. Foils for transmission electron microscopy (TEM) were made from local attack sites using a focussed ion beam/scanning electron microscope (FIB/SEM). The sections showed that clusters of S-phase particles underwent dealloying. The resulting copper sponge morphology, banding, preferred orientation and crystal defect structure as a result of plastic deformation have been characterised. With build-up of amorphous corrosion product, physical and electrical isolation of parts of the clusters developed, with the result of copper dissolution from the S-phase remnants.

  14. CD-SEM real time bias correction using reference metrology based modeling

    Science.gov (United States)

    Ukraintsev, V.; Banke, W.; Zagorodnev, G.; Archie, C.; Rana, N.; Pavlovsky, V.; Smirnov, V.; Briginas, I.; Katnani, A.; Vaid, A.

    2018-03-01

    Accuracy of patterning impacts yield, IC performance and technology time to market. Accuracy of patterning relies on optical proximity correction (OPC) models built using CD-SEM inputs and intra die critical dimension (CD) control based on CD-SEM. Sub-nanometer measurement uncertainty (MU) of CD-SEM is required for current technologies. Reported design and process related bias variation of CD-SEM is in the range of several nanometers. Reference metrology and numerical modeling are used to correct SEM. Both methods are slow to be used for real time bias correction. We report on real time CD-SEM bias correction using empirical models based on reference metrology (RM) data. Significant amount of currently untapped information (sidewall angle, corner rounding, etc.) is obtainable from SEM waveforms. Using additional RM information provided for specific technology (design rules, materials, processes) CD extraction algorithms can be pre-built and then used in real time for accurate CD extraction from regular CD-SEM images. The art and challenge of SEM modeling is in finding robust correlation between SEM waveform features and bias of CD-SEM as well as in minimizing RM inputs needed to create accurate (within the design and process space) model. The new approach was applied to improve CD-SEM accuracy of 45 nm GATE and 32 nm MET1 OPC 1D models. In both cases MU of the state of the art CD-SEM has been improved by 3x and reduced to a nanometer level. Similar approach can be applied to 2D (end of line, contours, etc.) and 3D (sidewall angle, corner rounding, etc.) cases.

  15. Self-esteem in adult prison population: The development and validation of the Self-Esteem Measure for Prisoners (SEM-P)

    OpenAIRE

    Debowska, Agata; Boduszek, Daniel; Sherretts, Nicole

    2016-01-01

    The main aim of the current study was to develop and validate the Self-Esteem Measure for Prisoners (SEM-P), composed of personal and prison self-esteem, among a systematically selected sample of prisoners (N = 1,794). Confirmatory factor analyses revealed that the SEM-P was best captured with the bifactor conceptualization reflecting two grouping factors (personal and prison self-esteem) and one general factor. Although factor loadings were stronger for the general factor, the two grouping f...

  16. TEM/SEM investigation of microstructural changes within the white etching area under rolling contact fatigue and 3-D crack reconstruction by focused ion beam

    International Nuclear Information System (INIS)

    Grabulov, A.; Ziese, U.; Zandbergen, H.W.

    2007-01-01

    The white etching area (WEA) surrounding the cracks formed under high-cycle rolling contact fatigue was investigated by transmission electron microscopy (TEM) and Dual Beam (scanning electron microscopy (SEM)/focused ion beam). SEM revealed the initiation of cracks formed around artificially introduced Al 2 O 3 inclusions in the model steel (composition similar to SAE 52100). TEM investigations showed a microstructural difference between the WEA (formation of nanocrystalline ferrite) and the steel matrix (tempered martensitic structure). A three-dimensional image of the crack reconstructed from ∼400 Dual Beam cross-section images is reported

  17. Labyrinths, columns and cavities: new internal features of pollen grain walls in the Acanthaceae detected by FIB-SEM.

    Science.gov (United States)

    House, Alisoun; Balkwill, Kevin

    2016-03-01

    External pollen grain morphology has been widely used in the taxonomy and systematics of flowering plants, especially the Acanthaceae which are noted for pollen diversity. However internal pollen wall features have received far less attention due to the difficulty of examining the wall structure. Advancing technology in the field of microscopy has made it possible, with the use of a focused ion beam-scanning electron microscope (FIB-SEM), to view the structure of pollen grain walls in far greater detail and in three dimensions. In this study the wall structures of 13 species from the Acanthaceae were investigated for features of potential systematic relevance. FIB-SEM was applied to obtain precise cross sections of pollen grains at selected positions for examining the wall ultrastructure. Exploratory studies of the exine have thus far identified five basic structural types. The investigations also show that similar external pollen wall features may have a distinctly different internal structure. FIB-SEM studies have revealed diverse internal pollen wall features which may now be investigated for their systematic and functional significance.

  18. Epigallocatechin-3-gallate rapidly remodels PAP85-120, SEM1(45-107, and SEM2(49-107 seminal amyloid fibrils

    Directory of Open Access Journals (Sweden)

    Laura M. Castellano

    2015-09-01

    Full Text Available Semen harbors amyloid fibrils formed by proteolytic fragments of prostatic acid phosphatase (PAP248-286 and PAP85-120 and semenogelins (SEM1 and SEM2 that potently enhance HIV infectivity. Amyloid but not soluble forms of these peptides enhance HIV infection. Thus, agents that remodel these amyloid fibrils could prevent HIV transmission. Here, we confirm that the green tea polyphenol, epigallocatechin-3-gallate (EGCG, slowly remodels fibrils formed by PAP248-286 termed SEVI (semen derived enhancer of viral infection and also exerts a direct anti-viral effect. We elucidate for the first time that EGCG remodels PAP85-120, SEM1(45-107, and SEM2(49-107 fibrils more rapidly than SEVI fibrils. We establish EGCG as the first small molecule that can remodel all four classes of seminal amyloid. The combined anti-amyloid and anti-viral properties of EGCG could have utility in preventing HIV transmission.

  19. APLIKASI STRUCTURAL EQUATION MODEL (SEM DALAM PENENTUAN ALTERNATIF PENGELOLAAN LINGKUNGAN INDUSTRI KOMPONEN ALAT BERAT BERBASIS PARTISIPASI DAN KEMITRAAN MASYARAKAT

    Directory of Open Access Journals (Sweden)

    Budi Setyo Utomo

    2012-07-01

    Full Text Available As a company engaged in the industrial sector by producing certain components and localized in an industrial area, there will be an impact on the environment. These impacts can be positive in the form of employment, reducing dependence on imported heavy equipment, increase in foreign exchange due to reduced imports and increased exports, increased government revenue from taxes, public facilities improvement and supporting infrastructure, and opening up opportunities for other related industries. These impacts can also be negative in the form of environmental degradation such as noise disturbance, dust, and micro climate change, and changes in social and cultural conditions surrounding the industry. Data analysis was performed descriptively and with the Structural Equation Model (SEM. SEM is a multivariate statistical technique which is a combination of factor analysis and regression analysis (correlation, which aims to test the connections between existing variables in a model, whether it is between the indicator with the construct, or the connections between constructs. SEM model consists of two parts, which is the latent variable model and the observed variable model. In contrast to ordinary regression linking the causality between the observed variables, it is also possible in SEM to identify the causality between latent variables. The results of SEM analysis showed that the developed model has a fairly high level of validity that is shown by the minimum fit chi-square value of 93.15 (P = 0.00029. Based on said model, it shows that the company's performance in waste management is largely determined by employee integrity and objectivity of the new employees followed later by the independence of the employees in waste management. The most important factor that determines the employee integrity in waste management in the model is honesty, individual wisdom, and a sense of responsibility. The most important factor in the employee objectivity

  20. A Proposal on the Quantitative Homogeneity Analysis Method of SEM Images for Material Inspections

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Hyun; Kim, Jong Woo; Shin, Chang Ho [Hanyang University, Seoul (Korea, Republic of); Choi, Jung-Hoon; Cho, In-Hak; Park, Hwan Seo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    A scanning electron microscope (SEM) is a method to inspect the surface microstructure of materials. The SEM uses electron beams for imaging high magnifications of material surfaces; therefore, various chemical analyses can be performed from the SEM images. Therefore, it is widely used for the material inspection, chemical characteristic analysis, and biological analysis. For the nuclear criticality analysis field, it is an important parameter to check the homogeneity of the compound material for using it in the nuclear system. In our previous study, the SEM was tried to use for the homogeneity analysis of the materials. In this study, a quantitative homogeneity analysis method of SEM images is proposed for the material inspections. The method is based on the stochastic analysis method with the information of the grayscales of the SEM images.

  1. The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.

    Science.gov (United States)

    Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C

    2014-01-01

    Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.

  2. A Proposal on the Quantitative Homogeneity Analysis Method of SEM Images for Material Inspections

    International Nuclear Information System (INIS)

    Kim, Song Hyun; Kim, Jong Woo; Shin, Chang Ho; Choi, Jung-Hoon; Cho, In-Hak; Park, Hwan Seo

    2015-01-01

    A scanning electron microscope (SEM) is a method to inspect the surface microstructure of materials. The SEM uses electron beams for imaging high magnifications of material surfaces; therefore, various chemical analyses can be performed from the SEM images. Therefore, it is widely used for the material inspection, chemical characteristic analysis, and biological analysis. For the nuclear criticality analysis field, it is an important parameter to check the homogeneity of the compound material for using it in the nuclear system. In our previous study, the SEM was tried to use for the homogeneity analysis of the materials. In this study, a quantitative homogeneity analysis method of SEM images is proposed for the material inspections. The method is based on the stochastic analysis method with the information of the grayscales of the SEM images

  3. Application of SEM and EDX in studying biomineralization in plant tissues.

    Science.gov (United States)

    He, Honghua; Kirilak, Yaowanuj

    2014-01-01

    This chapter describes protocols using formalin-acetic acid-alcohol (FAA) to fix plant tissues for studying biomineralization by means of scanning electron microscopy (SEM) and qualitative energy-dispersive X-ray microanalysis (EDX). Specimen preparation protocols for SEM and EDX mainly include fixation, dehydration, critical point drying (CPD), mounting, and coating. Gold-coated specimens are used for SEM imaging, while gold- and carbon-coated specimens are prepared for qualitative X-ray microanalyses separately to obtain complementary information on the elemental compositions of biominerals. During the specimen preparation procedure for SEM, some biominerals may be dislodged or scattered, making it difficult to determine their accurate locations, and light microscopy is used to complement SEM studies. Specimen preparation protocols for light microscopy generally include fixation, dehydration, infiltration and embedding with resin, microtome sectioning, and staining. In addition, microwave processing methods are adopted here to speed up the specimen preparation process for both SEM and light microscopy.

  4. The effect of home bleaching agents on the surface roughness of five different composite resins: A SEM evaluation.

    Science.gov (United States)

    Cengiz, Esra; Kurtulmus-Yilmaz, Sevcan; Ulusoy, Nuran; Deniz, Sule Tugba; Yuksel-Devrim, Ece

    2016-05-01

    The aim of this study was to investigate the effect of hydrogen peroxide (HP) and carbamide peroxide (CP) on the surface roughness of five different composite resins using profilometer and scanning electron microscope (SEM). Thirty-six specimens (1 mm thick, 10 mm in diameter) of five composite resins were fabricated. Each composite group was equally divided into three subgroups as control, CP and HP. In control group, specimens were stored in daily refreshed distilled water during the 14-day testing period. In other groups, 10% HP (Opalescence Treswhite) and 10% CP (Opalescence PF) were applied and surface roughness values (Ra) of each specimen were measured with a profilometer at the end of 14 days. Additionally, SEM analysis was performed to evaluate the surface deformations of composite resins. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests. Ra values of composite groups exposed to bleaching agents were statistically higher than control group (p composite group while SEM micrographs showed higher surface alterations at HP group compared to CP. Among the composite resins tested, Ceram-X Mono revealed the lowest Ra values after CP and HP applications as seen at SEM images. Home bleaching agents increased the surface roughness of all composites. Except CP applied Ceram-X mono specimens, Ra values of all composite resins evaluated in this study exceeded the critical limit of 0.2 μm. Ceram-X mono was the least affected composite material after bleaching application. SCANNING 38:277-283, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

  5. Comparative SEM and LM foliar epidermal and palyno-morphological studies of Amaranthaceae and its taxonomic implications.

    Science.gov (United States)

    Hussain, Amara Noor; Zafar, Muhammad; Ahmad, Mushtaq; Khan, Raees; Yaseen, Ghulam; Khan, Muhammad Saleem; Nazir, Abdul; Khan, Amir Muhammad; Shaheen, Shabnum

    2018-05-01

    Palynological features as well as comparative foliar epidermal using light and scanning electron microscope (SEM) of 17 species (10genera) of Amaranthaceae have been studied for its taxonomic significance. Different foliar and palynological micro-morphological characters were examined to explain their value in resolving the difficulty in identification. All species were amphistomatic but stomata on abaxial surface were more abundant. Taxonomically significant epidermal character including stomata type, trichomes (unicellular, multicellular, and capitate) and epidermal cells shapes (polygonal and irregular) were also observed. Pollens of this family are Polypantoporate, pores large, spheroidal, mesoporous region is sparsely to scabrate, densely psilate, and spinulose. All these characters can be active at species level for identification purpose. This study indicates that at different taxonomic levels, LM and SEM pollen and epidermal morphology is explanatory and significant to identify species and genera. © 2018 Wiley Periodicals, Inc.

  6. Comparison of SEM and VPSEM imaging techniques with respect to Streptococcus mutans biofilm topography.

    Science.gov (United States)

    Weber, Kathryn; Delben, Juliana; Bromage, Timothy G; Duarte, Simone

    2014-01-01

    The study compared images of mature Streptococcus mutans biofilms captured at increasing magnification to determine which microscopy method is most acceptable for imaging the biofilm topography and the extracellular polymeric substance (EPS). In vitro S. mutans biofilms were imaged using (1) scanning electron microscopy (SEM), which requires a dehydration process; (2) SEM and ruthenium red (SEM-RR), which has been shown to support the EPS of biofilms during the SEM dehydration; and (3) variable pressure scanning electron microscopy (VPSEM), which does not require the intensive dehydration process of SEM. The dehydration process and high chamber vacuum of both SEM techniques devastated the biofilm EPS, removed supporting structures, and caused cracking on the biofilm surface. The VPSEM offered the most comprehensive representation of the S. mutans biofilm morphology. VPSEM provides similar contrast and focus as the SEM, but the procedure is far less time-consuming, and the use of hazardous chemicals associated with SEM dehydration protocol is avoided with the VPSEM. The inaccurate representations of the biofilm EPS in SEM experimentation is a possible source of inaccurate data and impediments in the study of S. mutans biofilms. © 2013 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.

  7. SEM evaluation of human gingival fibroblasts growth onto CAD/CAM zirconia and veneering ceramic for zirconia

    Science.gov (United States)

    Zizzari, Vincenzo; Borelli, Bruna; De Colli, Marianna; Tumedei, Margherita; Di Iorio, Donato; Zara, Susi; Sorrentino, Roberto; Cataldi, Amelia; Gherlone, Enrico Felice; Zarone, Fernando; Tetè, Stefano

    2013-01-01

    Summary Aim To evaluate the growth of Human Gingival Fibroblasts (HGFs) cultured onto sample discs of CAD/CAM zirconia and veneering ceramic for zirconia by means of Scanning Electron Microscope (SEM) analysis at different experimental times. Methods A total of 26 experimental discs, divided into 2 groups, were used: Group A) CAD/CAM zirconia (3Y-TZP) discs (n=13); Group B) veneering ceramic for zirconia discs (n=13). HGFs were obtained from human gingival biopsies, isolated and placed in culture plates. Subsequently, cells were seeded on experimental discs at 7,5×103/cm2 concentration and cultured for a total of 7 days. Discs were processed for SEM observation at 3h, 24h, 72h and 7 days. Results In Group A, after 3h, HGFs were adherent to the surface and showed a flattened profile. The disc surface covered by HGFs resulted to be wider in Group A than in Group B samples. At SEM observation, after 24h and 72h, differences in cell attachment were slightly noticeable between the groups, with an evident flattening of HGFs on both surfaces. All differences between Group A and group B became less significant after 7 days of culture in vitro. Conclusions SEM analysis of HGFs showed differences in terms of cell adhesion and proliferation, especially in the early hours of culture. Results showed a better adhesion and cell growth in Group A than in Group B, especially up to 72h in vitro. Differences decreased after 7 days, probably because of the rougher surface of CAD/CAM zirconia, promoting better cell adhesion, compared to the smoother surface of veneering ceramic. PMID:24611089

  8. SEM study of the effects of crude oil on the gills and air breathing organs of climbing perch, Anabas testudineus

    International Nuclear Information System (INIS)

    Prasad, M.S.

    1991-01-01

    Ultrastructural studies on the effects of crude oil on the gills are scanty. Recently, researchers studied the effect of crude oil on the air breathing organs of striped gourami using scanning electron microscope and observed mucous cell hyperplasia coupled with telangiectasis in the epithelia of air breathing organs. The present investigation has been undertaken to study crude oil toxicity by observing the morphological changes occurring in the epithelia of gills and air breathing organs of climbing perch, Anabas testudineus at SEM level. Since the epithelia of gills and air breathing organs function in two different media, a comparative account for their sensitivity to crude oil solutions would be informative

  9. Cryogenic-SEM investigation of CO{sub 2} hydrate morphologies

    Energy Technology Data Exchange (ETDEWEB)

    Camps, A.P.; Milodowski, A.; Rochelle, C.; Williams, J.F.; Jackson, P. D. [British Geological Survey, Keyworth, Nottinghamshire (United Kingdom); Camps, A.P; Lovell, M.; Williams, J.F. [Leicester Univ., Leicester (United Kingdom). Dept. of Geology

    2008-07-01

    Gas hydrates occur naturally around the world in the shallow-marine geosphere, and are seen as a drilling hazard in the petroleum industry due to their role in the carbon cycle, and their possible contribution in past and present climate change. Hydrates are ice-like structures composed of cages of water molecules containing one or more guest molecules, such as methane and carbon dioxide (CO{sub 2}). CO{sub 2} hydrates also occur naturally on earth and are being investigated for their potential to store large volumes of CO{sub 2} to reduce atmospheric emissions of greenhouse gases as a climate change mitigation strategy. However, the mineralogy and formation processes of hydrates are relatively poorly understood. Different imaging techniques have been utilized to study gas hydrates, such as nuclear magnetic resonance, magnetic resonance imaging, and x-ray computed tomography. Scanning Electron Microscopy (SEM) at cryogenic temperatures is another technique to study hydrates, and has been used successfully for investigation of methane and CO{sub 2} hydrates. This paper presented a study that investigated CO{sub 2} hydrates formed in laboratories, using a cryogenic-SEM. The paper presented the study methods and observations, including euhedral crystalline carbon dioxide hydrate; acicular carbon dioxide hydrate; granoblastic carbon dioxide hydrate; and gas rich carbon dioxide hydrate. It was concluded that the investigation produced various different hydrate morphologies resulting from different formation conditions. Morphologies ranged from well-defined euhedral crystals to acicular needles, and more complex, intricate forms. 22 refs., 6 figs., 1 appendix.

  10. Three-dimensional characterization of ODS ferritic steel using by FIB-SEM serial sectioning method.

    Science.gov (United States)

    Endo, T; Sugino, Y; Ohono, N; Ukai, S; Miyazaki, N; Wang, Y; Ohnuki, S

    2014-11-01

    Considerable attention has been paid to the research of the electron tomography due to determine the three-dimensional (3D) structure of materials [1]. One of the electron tomography techniques, focused ion beam/scanning electron microscopy (FIB-SEM) imaging has advantages of high resolutions (10 nm), large area observation (μm order) and simultaneous energy dispersive x- ray microanalysis (EDS)/ electron backscatter diffraction (EBSD) analysis. The purpose of this study, three-dimensional EBSD analysis of ODS ferritic steel which carried out cold work using FIB-SEM equipment was conducted, and it aimed at analyzing the microstructure obtained there. The zone annealing tests were conducted for ferritic steel [2,3], which were produced through mechanical alloying and hot-extrusion. After zone annealing, specimens were mechanically polished with #400∼4000 emery paper, 1 µm diamond paste and alumina colloidal silica. The serial sectioning and the 3D-electron backscattering diffraction (3D-EBSD) analysis were carried out. We made the micro pillar (30 x 30 x 15 µm). The EBSD measurements were carried out in each layer after serial sectioning at a step size and milling depth was 80 nm with 30 slices. After EBSD analysis, the series of cross-sectional images were aligned according to arbitrarily specified areas and then stacked up to form a volume. Consequently, we obtained the 3D-IPF maps for ODS ferritic steel. In this specimen, the {111} and {001} grains are layered by turns. In addition, the volume fraction value of both plane are similar. The aspect ratio increases with specimen depth. The 3D-EBSD mapping is useful to analysis of the bulk material since this method obtain many microstructure information, such a shape, volume and orientation of the crystal, grain boundary. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. ERDA, RBS, TEM and SEM characterization of microstructural evolution in helium-implanted Hastelloy N alloy

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Jie [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049 (China); Bao, Liangman [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Huang, Hefei, E-mail: huanghefei@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, Yan, E-mail: liyan@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Lei, Qiantao [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Deng, Qi [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Liu, Zhe; Yang, Guo [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049 (China); Shi, Liqun [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)

    2017-05-15

    Hastelloy N alloy was implanted with 30 keV, 5 × 10{sup 16} ions/cm{sup 2} helium ions at room temperature, and subsequent annealed at 600 °C for 1 h and further annealed at 850 °C for 5 h in vacuum. Using elastic recoil detection analysis (ERDA) and transmission electron microscopy (TEM), the depth profiles of helium concentration and helium bubbles in helium-implanted Hastelloy N alloy were investigated, respectively. The diffusion of helium and molybdenum elements to surface occurred during the vacuum annealing at 850 °C (5 h). It was also observed that bubbles in molybdenum-enriched region were much larger in size than those in deeper region. In addition, it is worth noting that plenty of nano-holes can be observed on the surface of helium-implanted sample after high temperature annealing by scanning electron microscope (SEM). This observation provides the evidence for the occurrence of helium release, which can be also inferred from the results of ERDA and TEM analysis.

  12. Dyadic Interactions in Service Encounter: Bayesian SEM Approach

    Science.gov (United States)

    Sagan, Adam; Kowalska-Musiał, Magdalena

    Dyadic interactions are an important aspects in service encounters. They may be observed in B2B distribution channels, professional services, buying centers, family decision making or WOM communications. The networks consist of dyadic bonds that form dense but weak ties among the actors.

  13. Real-time SEM studies in controlled reactive atmospheres

    Science.gov (United States)

    Gallagher, B. D.; Garcia, A., III; Alonzo, J. R.

    1985-01-01

    A unique scanning electron accessory has been developed that allows the observation of specimens under partial pressures of any gas. The sample is placed in a metal support boat inside a special sample holder. The sample in the boat is imaged on a CRT and is simultaneously recorded on a videotape, allowing the reaction between the sample and the gas to be observed in real time. Sample changes can be seen continuously as the sample is being heated or cooled. This process allows the observation of material transformations such as phase changes as they happen. Temperatures as high as 1000 C have been used and are continuously monitored using a thermocouple with a digital display on the CRT and videotape. X-ray analyses can also be run before and after any reactions. In the study described here, thick-film screen-printing inks using molybdenum/tin compositions as a replacement for silver were developed to be used on terrestrial photovoltaic cells. Pieces were placed on the sample stage and heated in both O2 and H2 atmospheres. The results were used to determine the most effective frits to be used in the thick-film inks.

  14. A combined optical, SEM and STM study of growth spirals on the polytypic cadmium iodide crystals

    Science.gov (United States)

    Singh, Rajendra; Samanta, S. B.; Narlikar, A. V.; Trigunayat, G. C.

    2000-05-01

    Some novel results of a combined sequential study of growth spirals on the basal surface of the richly polytypic CdI 2 crystals by optical microscopy, scanning electron microscopy (SEM) and scanning tunneling microscopy (STM) are presented and discussed. Under the high resolution and magnification achieved in the scanning electron microscope, the growth steps of large heights seen in the optical micrographs are found to have a large number of additional steps of smaller heights existing between any two adjacent large height growth steps. When further seen by a scanning tunneling microscope, which provides still higher resolution, sequences of unit substeps, each of height equal to the unit cell height of the underlying polytype, are revealed to exist on the surface. Several large steps also lie between the unit steps, with heights equal to an integral multiple of either the unit cell height of the underlying polytype or the thickness of a molecular sheet I-Cd-I. It is suggested that initially a giant screw dislocation may form by brittle fracture of the crystal platelet, which may gradually decompose into numerous unit dislocations during subsequent crystal growth.

  15. DETERMINANTS OF CASH WAQF CONTRIBUTION IN KLANG VALLEY AND SELANGOR: A SEM APPROACH

    Directory of Open Access Journals (Sweden)

    Muhammad Rizky Prima Sakti

    2016-08-01

    Full Text Available Cash waqf is becoming one of the popular Islamic financial instruments which not only focus on the religiosity but also has significant impact to the ummah development. This waqf scheme does not require richness in wealth, yet everybody in the society can contribute to cash waqf. The importance of cash waqf is getting popular as it has benefited in many ways, for example it can be used to develop assets and abandoned land for business and agricultural purposes. In addition, cash waqf also can be utilized to help institutions who are facing financial problem or liquidity issues. Nonetheless, rarely we found in the literature that empirically examines the cash waqf determinants and contributions. This paper is one of the few empirical studies that investigate the determinants towards the contribution of cash waqf in Malaysia. The purpose of this paper is to investigate the main factors that influence people towards the contribution of cash waqf instruments, special reference to the Klang Valley and Selangor. This paper employs structural equation modeling (SEM to verify the determinants of cash waqf contribution. In doing so, we use primary data by distributing self-administrated questionnaire constituting a sample of 114 respondents from Klang Valley and Selangor. Our empirical results reveal that the main factors that driven people towards the contribution of cash waqf products are attitude and social influences, however interestingly religion obligation is not influence the contribution of cash waqf.

  16. SEM, Scanning Auger and XPS characterization of chemically pretreated Ti surfaces intended for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Pisarek, M. [Faculty of Materials Science and Engineering, Warsaw University of Technology, Woloska 141, 02-507 Warsaw (Poland); Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw (Poland)], E-mail: marcinp@ichf.edu.pl; Lewandowska, M. [Faculty of Materials Science and Engineering, Warsaw University of Technology, Woloska 141, 02-507 Warsaw (Poland); Roguska, A. [Faculty of Materials Science and Engineering, Warsaw University of Technology, Woloska 141, 02-507 Warsaw (Poland); Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw (Poland); Kurzydlowski, K.J. [Faculty of Materials Science and Engineering, Warsaw University of Technology, Woloska 141, 02-507 Warsaw (Poland); Janik-Czachor, M. [Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw (Poland)

    2007-07-15

    Titanium is known as a biocompatible metal characterized by biological and corrosion immunity and good mechanical properties, including a high fracture toughness. In a variety of environments, this metal undergoes 'natural' oxidation which determine its resistance to corrosion. It can also be exposed to chemical treatments in acidic or alkaline solutions which 'enforces' chemical and morphological changes of Ti surface. Those methods, if well controlled, may increase the effective Ti surface area, making it more biocompatible. However, the morphological and chemical factors responsible for their interactions with biological cells are still not well known. The aim of this work was to compare surface chemical and morphological changes introduced by commonly used aqueous NaOH pretreatment with those occurring in a new 'piranha' acidic solution. Particular attention was paid to possible changes which may be decisive for the biocompatibility of the Ti-elements subjected to these surface modifications. Surface analytical techniques such as Auger electron spectroscopy (AES) or X-ray photoelectron spectroscopy (XPS) combined with Ar{sup +} ion sputtering allowed us to investigate in detail the chemical composition of Ti oxide layers. SEM examinations provided morphological characterization of the surface of Ti samples. The results revealed large difference in morphology of Ti surfaces pretreated with different procedures whereas only minor difference in the chemistry of the surfaces were detected.

  17. Self-assembled silver nanoparticles monolayers on mica-AFM, SEM, and electrokinetic characteristics

    International Nuclear Information System (INIS)

    Oćwieja, Magdalena; Morga, Maria; Adamczyk, Zbigniew

    2013-01-01

    A monodisperse silver particle suspension was produced by a chemical reduction method in an aqueous medium using sodium citrate. The average particle size determined by dynamic light scattering (DLS), transmission electron microscopy (TEM), and atomic force microscopy (AFM) was 28.5 nm. The DLS measurements confirmed that the suspension was stable for the ionic strength up to 3 × 10 −2 M NaCl. The electrophoretic mobility measurements revealed that the electrokinetic charge of particles was negative for pH range 3–10, assuming −50 e for pH = 9 and 0.01 M NaCl. Using the suspension, silver particle monolayers on mica modified by poly(allylamine hydrochloride) were produced under diffusion-controlled transport. Monolayer coverage, quantitatively determined by AFM and SEM, was regulated within broad limits by adjusting the nanoparticle deposition time. This allowed one to uniquely express the zeta potential of silver monolayers, determined by the in situ streaming potential measurements, in terms of particle coverage. Such dependencies obtained for various ionic strengths and pH, were successfully interpreted in terms of the 3D electrokinetic model. A universal calibrating graph was produced in this way, enabling one to determine silver monolayer coverage from the measured value of the streaming potential. Our experimental data prove that it is feasible to produce uniform and stable silver particle monolayers of well-controlled coverage and defined electrokinetic properties.

  18. Self-assembled silver nanoparticles monolayers on mica-AFM, SEM, and electrokinetic characteristics.

    Science.gov (United States)

    Oćwieja, Magdalena; Morga, Maria; Adamczyk, Zbigniew

    2013-03-01

    A monodisperse silver particle suspension was produced by a chemical reduction method in an aqueous medium using sodium citrate. The average particle size determined by dynamic light scattering (DLS), transmission electron microscopy (TEM), and atomic force microscopy (AFM) was 28.5 nm. The DLS measurements confirmed that the suspension was stable for the ionic strength up to 3 × 10 -2  M NaCl. The electrophoretic mobility measurements revealed that the electrokinetic charge of particles was negative for pH range 3-10, assuming -50  e for pH = 9 and 0.01 M NaCl. Using the suspension, silver particle monolayers on mica modified by poly(allylamine hydrochloride) were produced under diffusion-controlled transport. Monolayer coverage, quantitatively determined by AFM and SEM, was regulated within broad limits by adjusting the nanoparticle deposition time. This allowed one to uniquely express the zeta potential of silver monolayers, determined by the in situ streaming potential measurements, in terms of particle coverage. Such dependencies obtained for various ionic strengths and pH, were successfully interpreted in terms of the 3D electrokinetic model. A universal calibrating graph was produced in this way, enabling one to determine silver monolayer coverage from the measured value of the streaming potential. Our experimental data prove that it is feasible to produce uniform and stable silver particle monolayers of well-controlled coverage and defined electrokinetic properties.

  19. Multi Scale Finite Element Analyses By Using SEM-EBSD Crystallographic Modeling and Parallel Computing

    International Nuclear Information System (INIS)

    Nakamachi, Eiji

    2005-01-01

    A crystallographic homogenization procedure is introduced to the conventional static-explicit and dynamic-explicit finite element formulation to develop a multi scale - double scale - analysis code to predict the plastic strain induced texture evolution, yield loci and formability of sheet metal. The double-scale structure consists of a crystal aggregation - micro-structure - and a macroscopic elastic plastic continuum. At first, we measure crystal morphologies by using SEM-EBSD apparatus, and define a unit cell of micro structure, which satisfy the periodicity condition in the real scale of polycrystal. Next, this crystallographic homogenization FE code is applied to 3N pure-iron and 'Benchmark' aluminum A6022 polycrystal sheets. It reveals that the initial crystal orientation distribution - the texture - affects very much to a plastic strain induced texture and anisotropic hardening evolutions and sheet deformation. Since, the multi-scale finite element analysis requires a large computation time, a parallel computing technique by using PC cluster is developed for a quick calculation. In this parallelization scheme, a dynamic workload balancing technique is introduced for quick and efficient calculations

  20. On the use of SEM correlative tools for in situ mechanical tests.

    Science.gov (United States)

    Shi, Qiwei; Roux, Stéphane; Latourte, Félix; Hild, François; Loisnard, Dominique; Brynaert, Nicolas

    2018-01-01

    In situ SEM mechanical tests are key to study crystal plasticity. In particular, imaging and diffraction (EBSD) allow microstructure and surface kinematics to be monitored all along the test. However, to get a full benefit from different modalities, it is necessary to register all images and crystallographic orientation maps from EBSD into the same frame. Different correlative approaches tracking either Pt surface markings, crystal orientations or grain boundaries, allow such registrations to be performed and displacement as well as rotation fields to be measured, a primary information for crystal plasticity identification. However, the different contrasts that are captured in different modalities and unavoidable stage motions also give rise to artifacts that are to be corrected to register the different information onto the same material points. The same image correlation tools reveal very powerful to correct such artifacts. Illustrated by an in situ uniaxial tensile test performed on a bainitic-ferritic steel sample, recent advances in image correlation techniques are reviewed and shown to provide a comprehensive picture of local strain and rotation maps. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. QEM*SEM: a necessary tool in the metallurgical evaluation of ore bodies

    International Nuclear Information System (INIS)

    Creelman, R.A.; Gottlieb, P.; Sutherland, D.; Jackson, R.

    1989-01-01

    The QEM*SEM system for automated image analysis of mineral samples is described. Details of the equipment are given together with information on the methods of measurement. Finally some practical applications are described where QEM*SEM has been used for the solution of metallurgical problems. 14 refs., 1 fig

  2. Strategic Enrolment Management (SEM) in Self-Financed Higher Education of Hong Kong: Evaluation and Measurement

    Science.gov (United States)

    Ng, Peggy; Galbraith, Craig

    2016-01-01

    The purpose of this study is to examine how the dimensions of strategic enrolment management (SEM) tie to the success metrics in the area of enrolment, retention and graduation from senior and programme management perspectives of a self-financed institution in Hong Kong. The literature on SEM has demonstrated that managing enrolment is a global…

  3. Shocked quartz in the SEM: Distinction between amorphous and healed PDFs

    NARCIS (Netherlands)

    Hamers, M.F.; Pennock, G.M.; Drury, M.R.

    2012-01-01

    Combined SEM techniques show that different CL signatures of PDFs are related to fresh and healed microstructures of PDFs and host quartz. This is confirmed by TEM results. A combination of SEM techniques can give the same type of information as TEM

  4. In-Situ tensile testing of propellants in SEM: influence of temperature

    NARCIS (Netherlands)

    Di Benedetto, G.L.; Ramshorst, M.C.J.; Duvalois, W.; Hooijmeijer, P.; Heijden, A. van der

    2017-01-01

    A tensile module system placed within a Scanning Electron Microscope (SEM) was utilized to conduct insitu tensile testing of propellant samples. The tensile module system allows for real-time in-situ SEM analysis of the samples to determine the failure mechanism of the propellant material under

  5. Image contrast enhancement of Ni/YSZ anode during the slice-and-view process in FIB-SEM.

    Science.gov (United States)

    Liu, Shu-Sheng; Takayama, Akiko; Matsumura, Syo; Koyama, Michihisa

    2016-03-01

    Focused ion beam-scanning electron microscopy (FIB-SEM) is a widely used and easily operational equipment for three-dimensional reconstruction with flexible analysis volume. It has been using successfully and increasingly in the field of solid oxide fuel cell. However, the phase contrast of the SEM images is indistinct in many cases, which will bring difficulties to the image processing. Herein, the phase contrast of a conventional Ni/yttria stabilized zirconia anode is tuned in an FIB-SEM with In-Lens secondary electron (SE) and backscattered electron detectors. Two accessories, tungsten probe and carbon nozzle, are inserted during the observation. The former has no influence on the contrast. When the carbon nozzle is inserted, best and distinct contrast can be obtained by In-Lens SE detector. This method is novel for contrast enhancement. Phase segmentation of the image can be automatically performed. The related mechanism for different images is discussed. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  6. Vegetable processing wastes addition to improve swine manure anaerobic digestion: Evaluation in terms of methane yield and SEM characterization

    International Nuclear Information System (INIS)

    Molinuevo-Salces, Beatriz; González-Fernández, Cristina; Gómez, Xiomar; García-González, María Cruz; Morán, Antonio

    2012-01-01

    Highlights: ► Vegetable waste as co-substrate for swine manure anaerobic digestion. ► Two hydraulic retention times of 25 and 15 d, respectively. ► SEM characterization of anaerobic sludges to observe microbial composition. ► Vegetable waste as co-substrate increases methane yields up to three times. ► Microbial composition changes after 120 d of digestion. -- Abstract: The effect of adding vegetable waste as a co-substrate in the anaerobic digestion of swine manure was investigated. The study was carried out at laboratory scale using semi-continuous stirred tank reactors working at 37 °C. Organic loading rates (OLRs) of 0.4 and 0.6 g VS L −1 d −1 were evaluated, corresponding to hydraulic retention times (HRTs) of 25 and 15 d, respectively. The addition of vegetable wastes (50% dw/dw) resulted in an improvement of 3 and 1.4-fold in methane yields at HRTs of 25 and 15 d, respectively. Changes on microbial morphotypes were studied by Scanning Electron Microscopy (SEM). Samples analyzed were sludge used as inoculum and digestate obtained from swine manure anaerobic reactors. SEM pictures demonstrated that lignocellulosic material was not completely degraded. Additionally, microbial composition was found to change to cocci and rods morphotypes after 120 d of anaerobic digestion.

  7. AFM and SEM study of the effects of etching on IPS-Empress 2 TM dental ceramic

    Science.gov (United States)

    Luo, X.-P.; Silikas, N.; Allaf, M.; Wilson, N. H. F.; Watts, D. C.

    2001-10-01

    The aim of this study was to investigate the effects of increasing etching time on the surface of the new dental material, IPS-Empress 2 TM glass ceramic. Twenty one IPS-Empress 2 TM glass ceramic samples were made from IPS-Empress 2 TM ingots through lost-wax, hot-pressed ceramic fabrication technology. All samples were highly polished and cleaned ultrasonically for 5 min in acetone before and after etching with 9.6% hydrofluoric acid gel. The etching times were 0, 10, 20, 30, 60, 90 and 120 s respectively. Microstructure was analysed by scanning electron microscopy (SEM) and atomic force microscopy (AFM) was used to evaluate the surface roughness and topography. Observations with SEM showed that etching with hydrofluoric acid resulted in preferential dissolution of glass matrix, and that partially supported crystals within the glass matrix were lost with increasing etching time. AFM measurements indicated that etching increased the surface roughness of the glass-ceramic. A simple least-squares linear regression was used to establish a relationship between surface roughness parameters ( Ra, RMS), and etching time, for which r2>0.94. This study demonstrates the benefits of combining two microscopic methods for a better understanding of the surface. SEM showed the mode of action of hydrofluoric acid on the ceramic and AFM provided valuable data regarding the extent of surface degradation relative to etching time.

  8. Quantitative roughness characterization and 3D reconstruction of electrode surface using cyclic voltammetry and SEM image

    Energy Technology Data Exchange (ETDEWEB)

    Dhillon, Shweta; Kant, Rama, E-mail: rkant@chemistry.du.ac.in

    2013-10-01

    Area measurements from cyclic voltammetry (CV) and image from scanning electron microscopy (SEM) are used to characterize electrode statistical morphology, 3D surface reconstruction and its electroactivity. SEM images of single phased materials correspond to two-dimensional (2D) projections of 3D structures, leading to an incomplete characterization. Lack of third dimension information in SEM image is circumvented using equivalence between denoised SEM image and CV area measurements. This CV-SEM method can be used to estimate power spectral density (PSD), width, gradient, finite fractal nature of roughness and local morphology of the electrode. We show that the surface morphological statistical property like distribution function of gradient can be related to local electro-activity. Electrode surface gradient micrographs generated here can provide map of electro-activity sites. Finally, the densely and uniformly packed small gradient over the Pt-surface is the determining criterion for high intrinsic electrode activity.

  9. Two novel approaches to study arthropod anatomy by using dualbeam FIB/SEM.

    Science.gov (United States)

    Di Giulio, Andrea; Muzzi, Maurizio

    2018-03-01

    Transmission Electron Microscopy (TEM) has always been the conventional method to study arthropod ultrastructure, while the use of Scanning Electron Microscopy (SEM) was mainly devoted to the examination of the external cuticular structures by secondary electrons. The new generation field emission SEMs are capable to generate images at sub-cellular level, comparable to TEM images employing backscattered electrons. The potential of this kind of acquisition becomes very powerful in the dual beam FIB/SEM where the SEM column is combined with a Focused Ion Beam (FIB) column. FIB uses ions as a nano-scalpel to slice samples fixed and embedded in resin, replacing traditional ultramicrotomy. We here present two novel methods, which optimize the use of FIB/SEM for studying arthropod anatomy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Quantitative roughness characterization and 3D reconstruction of electrode surface using cyclic voltammetry and SEM image

    International Nuclear Information System (INIS)

    Dhillon, Shweta; Kant, Rama

    2013-01-01

    Area measurements from cyclic voltammetry (CV) and image from scanning electron microscopy (SEM) are used to characterize electrode statistical morphology, 3D surface reconstruction and its electroactivity. SEM images of single phased materials correspond to two-dimensional (2D) projections of 3D structures, leading to an incomplete characterization. Lack of third dimension information in SEM image is circumvented using equivalence between denoised SEM image and CV area measurements. This CV-SEM method can be used to estimate power spectral density (PSD), width, gradient, finite fractal nature of roughness and local morphology of the electrode. We show that the surface morphological statistical property like distribution function of gradient can be related to local electro-activity. Electrode surface gradient micrographs generated here can provide map of electro-activity sites. Finally, the densely and uniformly packed small gradient over the Pt-surface is the determining criterion for high intrinsic electrode activity.

  11. GAGG:ce single crystalline films: New perspective scintillators for electron detection in SEM.

    Science.gov (United States)

    Bok, Jan; Lalinský, Ondřej; Hanuš, Martin; Onderišinová, Zuzana; Kelar, Jakub; Kučera, Miroslav

    2016-04-01

    Single crystal scintillators are frequently used for electron detection in scanning electron microscopy (SEM). We report gadolinium aluminum gallium garnet (GAGG:Ce) single crystalline films as a new perspective scintillators for the SEM. For the first time, the epitaxial garnet films were used in a practical application: the GAGG:Ce scintillator was incorporated into a SEM scintillation electron detector and it showed improved image quality. In order to prove the GAGG:Ce quality accurately, the scintillation properties were examined using electron beam excitation and compared with frequently used scintillators in the SEM. The results demonstrate excellent emission efficiency of the GAGG:Ce single crystalline films together with their very fast scintillation decay useful for demanding SEM applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Features of High-Latitude Ionospheric Irregularities Development as Revealed by Ground-Based GPS Observations, Satellite-Borne GPS Observations and Satellite In Situ Measurements over the Territory of Russia during the Geomagnetic Storm on March 17-18, 2015

    Science.gov (United States)

    Zakharenkova, I. E.; Cherniak, Iu. V.; Shagimuratov, I. I.; Klimenko, M. V.

    2018-01-01

    The dynamic picture of the response of the high- and mid-latitude ionosphere to the strong geomagnetic disturbances on March 17-18, 2015, has been studied with ground-based and satellite observations, mainly, by transionospheric measurements of delays of GPS (Global Positioning System) signals. The advantages of the joint use of ground-based GPS measurements and GPS measurements on board of the Swarm Low-Earth-Orbit satellite mission for monitoring of the appearance of ionospheric irregularities over the territory of Russia are shown for the first time. The results of analysis of ground-based and space-borne GPS observations, as well as satellite, in situ measurements, revealed large-scale ionospheric plasma irregularities observed over the territory of Russia in the latitude range of 50°-85° N during the main phase of the geomagnetic storm. The most intense ionospheric irregularities were detected in the auroral zone and in the region of the main ionospheric trough (MIT). It has been found that sharp changes in the phase of the carrier frequency of the navigation signal from all tracked satellites were recorded at all GPS stations located to the North from 55° MLAT. The development of a deep MIT was related to dynamic processes in the subauroral ionosphere, in particular, with electric fields of the intense subauroral polarization stream. Analysis of the electron and ion density values obtained by instruments on board of the Swarm and DMSP satellites showed that the zone of highly structured auroral ionosphere extended at least to heights of 850-900 km.

  13. Heavy metal elements in toiletries analyzed by INAA, ICP-MS and SEM-EDX

    International Nuclear Information System (INIS)

    Furuta, E.; Tagami, K.; Okada, Y.; Nakahara, H.

    2011-01-01

    Recently, many toiletries claiming inclusion of platinum (Pt), silver (Ag) and gold (Au) as additives are sold in ordinary cosmetics shops. However, their concentrations are not clearly indicated. In the present work, these toiletries were analyzed for heavy metal elements by instrumental neutron activation analysis (INAA) and inductively coupled plasma mass spectrometry (ICP-MS), and the particle sizes were observed by scanning electron microscope (SEM) and the constitutions of the small particles were analyzed by energy dispersive X-ray spectroscopy (EDX). The concentrations of Pt in the toiletries observed were from 1 to 80 ppm. The lower detection limit of Pt by INAA was about 1 ppm because of the presence of sodium in high concentrations for those samples. Consequently, some toiletries which should have had Pt according to the manufactures were found not to contain Pt probably because it was less than the detection limit. On the other hand, there were a few toiletries that were found to contain Ag although the addition of Ag was not mentioned by the manufactures. It is considered that these non-indicated Ag were included as impurities of the added Au. The concentrations of the non-indicated Ag were even higher than those of the indicated Ag. A very small amount of Sr, which was nominated in the negative list of Japan, was also detected in 2 out of 5 kinds of toiletries analyzed by ICP-MS. (orig.)

  14. Flare Observations

    Directory of Open Access Journals (Sweden)

    Benz Arnold O.

    2008-02-01

    Full Text Available Solar flares are observed at all wavelengths from decameter radio waves to gamma-rays at 100 MeV. This review focuses on recent observations in EUV, soft and hard X-rays, white light, and radio waves. Space missions such as RHESSI, Yohkoh, TRACE, and SOHO have enlarged widely the observational base. They have revealed a number of surprises: Coronal sources appear before the hard X-ray emission in chromospheric footpoints, major flare acceleration sites appear to be independent of coronal mass ejections (CMEs, electrons, and ions may be accelerated at different sites, there are at least 3 different magnetic topologies, and basic characteristics vary from small to large flares. Recent progress also includes improved insights into the flare energy partition, on the location(s of energy release, tests of energy release scenarios and particle acceleration. The interplay of observations with theory is important to deduce the geometry and to disentangle the various processes involved. There is increasing evidence supporting reconnection of magnetic field lines as the basic cause. While this process has become generally accepted as the trigger, it is still controversial how it converts a considerable fraction of the energy into non-thermal particles. Flare-like processes may be responsible for large-scale restructuring of the magnetic field in the corona as well as for its heating. Large flares influence interplanetary space and substantially affect the Earth’s lower ionosphere. While flare scenarios have slowly converged over the past decades, every new observation still reveals major unexpected results, demonstrating that solar flares, after 150 years since their discovery, remain a complex problem of astrophysics including major unsolved questions.

  15. Flare Observations

    Science.gov (United States)

    Benz, Arnold O.

    2017-12-01

    Solar flares are observed at all wavelengths from decameter radio waves to gamma-rays beyond 1 GeV. This review focuses on recent observations in EUV, soft and hard X-rays, white light, and radio waves. Space missions such as RHESSI, Yohkoh, TRACE, SOHO, and more recently Hinode and SDO have enlarged widely the observational base. They have revealed a number of surprises: Coronal sources appear before the hard X-ray emission in chromospheric footpoints, major flare acceleration sites appear to be independent of coronal mass ejections, electrons, and ions may be accelerated at different sites, there are at least 3 different magnetic topologies, and basic characteristics vary from small to large flares. Recent progress also includes improved insights into the flare energy partition, on the location(s) of energy release, tests of energy release scenarios and particle acceleration. The interplay of observations with theory is important to deduce the geometry and to disentangle the various processes involved. There is increasing evidence supporting magnetic reconnection as the basic cause. While this process has become generally accepted as the trigger, it is still controversial how it converts a considerable fraction of the energy into non-thermal particles. Flare-like processes may be responsible for large-scale restructuring of the magnetic field in the corona as well as for its heating. Large flares influence interplanetary space and substantially affect the Earth's ionosphere. Flare scenarios have slowly converged over the past decades, but every new observation still reveals major unexpected results, demonstrating that solar flares, after 150 years since their discovery, remain a complex problem of astrophysics including major unsolved questions.

  16. Characterisation of nanoparticles by means of high-resolution SEM/EDS in transmission mode

    International Nuclear Information System (INIS)

    Hodoroaba, V-D; Rades, S; Mielke, J; Ortel, E; Salge, T; Schmidt, R

    2016-01-01

    Advances in scanning electron microscopy (SEM) enable the high-resolution imaging of single nanoparticles (NPs) with sizes well below 10 nm. The SEM analysis in transmission mode (T-SEM) of NPs on thin film supports has many benefits when compared to the analysis of NPs on bulk substrates. The enhanced material (mass - thickness) contrast of the T-SEM imaging mode is well suited for in-depth and, particularly valuable, to very accurate, traceable, lateral dimensional measurements of NPs. Compared to samples prepared on bulk substrates, T-SEM with energy dispersive X-ray spectroscopy (EDS) achieves a drastically improved spatial resolution of the emitted X-rays. The poor signal-to-noise ratio of the X-ray spectra emitted by a single nanoparticle (NP) can be improved by the use of high-sensitivity (high collection solid angle) silicon drift (SDD), energy-dispersive X-ray spectrometers (EDS). The EDS spectral imaging of a single NP with a spatial resolution below 10 nm has become possible. This is demonstrated by means of various examples of nanostructures. Advanced data processing of T-SEM/EDS results sets the stage for the automated classification of NPs by feature analysis. This method combines the detection of morphological structures of interest by image processing of T-SEM micrographs with the chemical classification by EDS. (paper)

  17. Inter-operator and inter-device agreement and reliability of the SEM Scanner.

    Science.gov (United States)

    Clendenin, Marta; Jaradeh, Kindah; Shamirian, Anasheh; Rhodes, Shannon L

    2015-02-01

    The SEM Scanner is a medical device designed for use by healthcare providers as part of pressure ulcer prevention programs. The objective of this study was to evaluate the inter-rater and inter-device agreement and reliability of the SEM Scanner. Thirty-one (31) volunteers free of pressure ulcers or broken skin at the sternum, sacrum, and heels were assessed with the SEM Scanner. Each of three operators utilized each of three devices to collect readings from four anatomical sites (sternum, sacrum, left and right heels) on each subject for a total of 108 readings per subject collected over approximately 30 min. For each combination of operator-device-anatomical site, three SEM readings were collected. Inter-operator and inter-device agreement and reliability were estimated. Over the course of this study, more than 3000 SEM Scanner readings were collected. Agreement between operators was good with mean differences ranging from -0.01 to 0.11. Inter-operator and inter-device reliability exceeded 0.80 at all anatomical sites assessed. The results of this study demonstrate the high reliability and good agreement of the SEM Scanner across different operators and different devices. Given the limitations of current methods to prevent and detect pressure ulcers, the SEM Scanner shows promise as an objective, reliable tool for assessing the presence or absence of pressure-induced tissue damage such as pressure ulcers. Copyright © 2015 Bruin Biometrics, LLC. Published by Elsevier Ltd.. All rights reserved.

  18. Three-Dimensional (3D) Nanometrology Based on Scanning Electron Microscope (SEM) Stereophotogrammetry.

    Science.gov (United States)

    Tondare, Vipin N; Villarrubia, John S; Vlada R, András E

    2017-10-01

    Three-dimensional (3D) reconstruction of a sample surface from scanning electron microscope (SEM) images taken at two perspectives has been known for decades. Nowadays, there exist several commercially available stereophotogrammetry software packages. For testing these software packages, in this study we used Monte Carlo simulated SEM images of virtual samples. A virtual sample is a model in a computer, and its true dimensions are known exactly, which is impossible for real SEM samples due to measurement uncertainty. The simulated SEM images can be used for algorithm testing, development, and validation. We tested two stereophotogrammetry software packages and compared their reconstructed 3D models with the known geometry of the virtual samples used to create the simulated SEM images. Both packages performed relatively well with simulated SEM images of a sample with a rough surface. However, in a sample containing nearly uniform and therefore low-contrast zones, the height reconstruction error was ≈46%. The present stereophotogrammetry software packages need further improvement before they can be used reliably with SEM images with uniform zones.

  19. Sobre la estructura semántica de las palabras autosemánticas

    Directory of Open Access Journals (Sweden)

    Morales Ascencio Bernardo

    1993-06-01

    Full Text Available

    A partir de los conceptos de semema o estructura semémica y de los conceptos tradicionales de afijos y los accidentes gramaticales se plantea una supuesta estructura semántica profunda de la palabra, análoga a la de la oración en el modelo de la gramática de casos. Con base en este supuesto se reinterpretan algunas funciones semánticas de los afijos (particularmente de los sufijos, entre otras, como formas de la expresión de la modalidad léxica; se plantea una correlación entre rasgos semánticos específicos y las relaciones semánticas de caso. Por último se deducen algunas consideraciones pertinentes y se demuestra un isomorfismo entre la estructura profunda de la oración y la supuesta estructura semántica profunda de las palabras auto  semánticas.

  20. A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for the Surface of Mars: An Instrument for the Planetary Science Community

    Science.gov (United States)

    Edmunson, J.; Gaskin, J. A.; Danilatos, G.; Doloboff, I. J.; Effinger, M. R.; Harvey, R. P.; Jerman, G. A.; Klein-Schoder, R.; Mackie, W.; Magera, B.; hide

    2016-01-01

    The Miniaturized Variable Pressure Scanning Electron Microscope(MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Science (ROSES), will build upon previous miniaturized SEM designs for lunar and International Space Station (ISS) applications and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. By the end of the PICASSO work, a prototype of the primary proof-of-concept components (i.e., the electron gun, focusing optics and scanning system)will be assembled and preliminary testing in a Mars analog chamber at the Jet Propulsion Laboratory will be completed to partially fulfill Technology Readiness Level to 5 requirements for those components. The team plans to have Secondary Electron Imaging(SEI), Backscattered Electron (BSE) detection, and Energy Dispersive Spectroscopy (EDS) capabilities through the MVP-SEM.

  1. Development and application of loop-mediated isothermal amplification methods targeting the seM gene for detection of Streptococcus equi subsp. equi.

    Science.gov (United States)

    Hobo, Seiji; Niwa, Hidekazu; Oku, Kazuomi

    2012-03-01

    Loop-mediated isothermal amplification (LAMP) constitutes a potentially valuable diagnostic tool for rapid diagnosis of contagious diseases. In this study, we developed a novel LAMP method (seM-LAMP) to detect the seM gene of Streptococcus equi subsp. equi (S. equi), the causative agent of strangles in equids. The seM-LAMP successfully amplified the target sequence of the seM gene at 63°C within 60 min. The sensitivity of the seM-LAMP was slightly lower than the 2nd reaction of the seM semi-nested PCR. To evaluate the species specificity of the seM-LAMP, we tested 100 S. equi and 189 non-S. equi strains. Significant amplification of the DNA originating from S. equi was observed within 60 min incubation, but no amplification of non-S. equi DNA occurred. The results were identical to those of seM semi-nested PCR. To investigate the clinical usefulness of the methods, the seM-LAMP and the seM semi-nested PCR were used to screen 590 nasal swabs obtained during an outbreak of strangles. Both methods showed that 79 and 511 swabs were S. equi positive and negative, respectively, and the results were identical to those of the culture examination. These results indicate that the seM-LAMP is potentially useful for the reliable routine diagnosis of Streptococcus equi subsp. equi infections.

  2. Use of SEM and EDS analysis in the investigation of Al-Si-Cu piston alloy cast porosity

    Directory of Open Access Journals (Sweden)

    D. Kakaš

    2009-07-01

    Full Text Available Porosity formation was detected in the casting thinnest section in the proximity of the as cast surface and near the wall centerline. In order to investigate the cause of the porosity formation light microscopy was used to define as cast structure. After initial findings SEM and EDS analyses were performed. Based on the results it is possible to define cause of the observed porosity. A number of pores originates from the mould filling stage and entrainment of the oxide films, while others appear due to insufficient feeding during solidification.

  3. Diversity of seM in Streptococcus equi subsp. equi isolated from strangles outbreaks.

    Science.gov (United States)

    Libardoni, Felipe; Vielmo, Andréia; Farias, Luana; Matter, Letícia Beatriz; Pötter, Luciana; Spilki, Fernando Rosado; de Vargas, Agueda Castagna

    2013-03-23

    Strangles is the main upper respiratory tract disease of horses. There are currently no studies on the changes in alleles of the M protein gene (seM) in Brazilian isolates of Streptococcus equi ssp. equi (S. equi). This study aimed to analyze and differentiate molecularly S. equi isolates from equine clinical specimens from southern Brazil, between 1994 and 2010. seM alleles were analyzed in 47 isolates of S. equi obtained from clinical cases of strangles (15 Thoroughbred horses, 29 Crioulo breed horses and three Brasileiro de Hipismo--BH). seM alleles characterization was performed by comparing variable region sequences of the seM gene. The alleles were also phylogenetically grouped by Neighbor-joining analysis, which demonstrated the geographic distribution of those in properties from southern Brazil. Fifteen alleles of the gene seM were found among the 47 S. equi isolates analyzed. Among these, only one allele (seM-61), which was identified in seven isolates (14.9%), was found in the database PubMLST-seM. Within the new alleles, allele seM-115 was the most prevalent, having been found in 13 isolates (27.7%), followed by allele seM-117 in 10 isolates (21.3%). In the Brazilian horse population studied, there is greater diversity of M protein alleles in S. equi isolates compared to worldwide data deposited in PubMLST-seM. Among the 15 seM alleles identified, only one allele sequence was previously published. The alleles identification is important to control the disease by guiding selection of strains for the manufacture of commercial and autogenous vaccines. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Development of Focused Ion Beam technique for high speed steel 3D-SEM artefact fabrication

    DEFF Research Database (Denmark)

    Carli, Lorenzo; MacDonald, A. Nicole; De Chiffre, Leonardo

    2009-01-01

    The work describes preliminary manufacture by grinding, followed by machining on a Focused Ion Beam (FIB), of a high speed steel step artefact for 3D-SEM calibration. The FIB is coupled with a SEM in the so called dual beam instrument. The milling capabilities of FIB were checked from a qualitative...... point of view, using the dual beam SEM imaging, and quantitatively using a reference stylus instrument, to establish traceability. A triangular section having a depth of about 10 μm was machined, where the 50 μm curvature radius due to grinding was reduced to about 2 μm by FIB milling...

  5. The SEM description of interaction of a transient electromagnetic wave with an object

    Science.gov (United States)

    Pearson, L. W.; Wilton, D. R.

    1980-01-01

    The singularity expansion method (SEM), proposed as a means for determining and representing the transient surface current density induced on a scatterer by a transient electromagnetic wave is described. The resulting mathematical description of the transient surface current on the object is discussed. The data required to represent the electromagnetic scattering properties of a given object are examined. Experimental methods which were developed for the determination of the SEM description are discussed. The feasibility of characterizing the surface current induced on aircraft flying in proximity to a lightning stroke by way of SEM is examined.

  6. Palyno-morphological characteristics of gymnosperm flora of pakistan and its taxonomic implications with LM and SEM methods.

    Science.gov (United States)

    Khan, Raees; Ul Abidin, Sheikh Zain; Ahmad, Mushtaq; Zafar, Muhammad; Liu, Jie; Amina, Hafiza

    2018-01-01

    The present study is intended to assess gymnosperms pollen flora of Pakistan using Light Microscope (LM) and Scanning Electron Microscopy (SEM) for its taxonomic significance in identification of gymnosperms. Pollens of 35 gymnosperm species (12 genera and five families) were collected from its various distributional sites of gymnosperms in Pakistan. LM and SEM were used to investigate different palyno-morphological characteristics. Five pollen types (i.e., Inaperturate, Monolete, Monoporate, Vesiculate-bisaccate and Polyplicate) were observed. Six In equatorial view seven types of pollens were observed, in which ten species were sub-angular, nine species were Traingular, six species were Perprolate, three species were Rhomboidal, three species were semi-angular, two species were rectangular and two species were prolate. While five types of pollen were observed in polar view, in which ten species were Spheroidal, nine species were Angular, eight were Interlobate, six species were Circular, two species were Elliptic. Eighteen species has rugulate and 17 species has faveolate ornamentation. Eighteen species has verrucate and 17 have gemmate type sculpturing. The data was analysed through cluster analysis. The study showed that these palyno-morphological features have significance value in classification and identification of gymnosperms. Based on these different palyno-morphological features, a taxonomic key was proposed for the accurate and fast identifications of gymnosperms from Pakistan. © 2017 Wiley Periodicals, Inc.

  7. SEM and TEM Characterization of As-Fabricated U-7Mo Disperson Fuel Plates

    International Nuclear Information System (INIS)

    Keiser, D.D. Jr.; Yao, B.; Perez, E.; Sohn, Y.H.

    2009-01-01

    The starting microstructure of a dispersion fuel plate can have a dramatic impact on the overall performance of the plate during irradiation. To improve the understanding of the as-fabricated microstructures of dispersion fuel plates, SEM and TEM analysis have been performed on RERTR-9A archive fuel plates, which went through an additional hot isostatic procsssing (HIP) step during fabrication. The fuel plates had depleted U-7Mo fuel particles dispersed in either Al-2Si or 4043 Al alloy matrix. For the characterized samples, it was observed that a large fraction of the ?-phase U-7Mo alloy particles had decomposed during fabrication, and in areas near the fuel/matrix interface where the transformation products were present significant fuel/matrix interaction had occurred. Relatively thin Si-rich interaction layers were also observed around the U-7Mo particles. In the thick interaction layers, (U)(Al,Si)3 and U6Mo4Al43 were identified, and in the thin interaction layers U(Al,Si)3, U3Si3Al2, U3Si5, and USi1.88-type phases were observed. The U3Si3Al2 phase contained some Mo. Based on the results of this work, exposure of dispersion fuel plates to relatively high temperatures during fabrication impacts the overall microstructure, particularly the nature of the interaction layers around the fuel particles. The time and temperature of fabrication should be carefully controlled in order to produce the most uniform Si-rich layers around the U-7Mo particles.

  8. A New Approach to Studying Biological and Soft Materials Using Focused Ion Beam Scanning Electron Microscopy (FIB SEM)

    International Nuclear Information System (INIS)

    Stokes, D J; Morrissey, F; Lich, B H

    2006-01-01

    Over the last decade techniques such as confocal light microscopy, in combination with fluorescent labelling, have helped biologists and life scientists to study biological architectures at tissue and cell level in great detail. Meanwhile, obtaining information at very small length scales is possible with the combination of sample preparation techniques and transmission electron microscopy (TEM) or scanning transmission electron microscopy (STEM). Scanning electron microscopy (SEM) is well known for the determination of surface characteristics and morphology. However, the desire to understand the three dimensional relationships of meso-scale hierarchies has led to the development of advanced microscopy techniques, to give a further complementary approach. A focused ion beam (FIB) can be used as a nano-scalpel and hence allows us to reveal internal microstructure in a site-specific manner. Whilst FIB instruments have been used to study and verify the three-dimensional architecture of man made materials, SEM and FIB technologies have now been brought together in a single instrument representing a powerful combination for the study of biological specimens and soft materials. We demonstrate the use of FIB SEM to study three-dimensional relationships for a range of length scales and materials, from small-scale cellular structures to the larger scale interactions between biomedical materials and tissues. FIB cutting of heterogeneous mixtures of hard and soft materials, resulting in a uniform cross-section, has proved to be of particular value since classical preparation methods tend to introduce artefacts. Furthermore, by appropriate selection, we can sequentially cross-section to create a series of 'slices' at specific intervals. 3D reconstruction software can then be used to volume-render information from the 2D slices, enabling us to immediately see the spatial relationships between microstructural components

  9. In situ TEM/SEM electronic/mechanical characterization of nano material with MEMS chip

    International Nuclear Information System (INIS)

    Wang Yuelin; Li Tie; Zhang Xiao; Zeng Hongjiang; Jin Qinhua

    2014-01-01

    Our investigation of in situ observations on electronic and mechanical properties of nano materials using a scanning electron microscope (SEM) and a transmission electron microscope (TEM) with the help of traditional micro-electro-mechanical system (MEMS) technology has been reviewed. Thanks to the stability, continuity and controllability of the loading force from the electrostatic actuator and the sensitivity of the sensor beam, a MEMS tensile testing chip for accurate tensile testing in the nano scale is obtained. Based on the MEMS chips, the scale effect of Young's modulus in silicon has been studied and confirmed directly in a tensile experiment using a transmission electron microscope. Employing the nanomanipulation technology and FIB technology, Cu and SiC nanowires have been integrated into the tensile testing device and their mechanical, electronic properties under different stress have been achieved, simultaneously. All these will aid in better understanding the nano effects and contribute to the designation and application in nano devices. (invited papers)

  10. Optical and microstructural characterization of porous silicon using photoluminescence, SEM and positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Cheung, C K; Nahid, F; Cheng, C C; Beling, C D; Fung, S; Ling, C C; Djurisic, A B; Pramanik, C; Saha, H; Sarkar, C K

    2007-01-01

    We have studied the dependence of porous silicon morphology and porosity on fabrication conditions. N-type (100) silicon wafers with resistivity of 2-5 Ω cm were electrochemically etched at various current densities and anodization times. Surface morphology and the thickness of the samples were examined by scanning electron microscopy (SEM). Detailed information of the porous silicon layer morphology with variation of preparation conditions was obtained by positron annihilation spectroscopy (PAS): the depth-defect profile and open pore interconnectivity on the sample surface has been studied using a slow positron beam. Coincidence Doppler broadening spectroscopy (CDBS) was used to study the chemical environment of the samples. The presence of silicon micropores with diameter varying from 1.37 to 1.51 nm was determined by positron lifetime spectroscopy (PALS). Visible luminescence from the samples was observed, which is considered to be a combination effect of quantum confinement and the effect of Si = O double bond formation near the SiO 2 /Si interface according to the results from photoluminescence (PL) and positron annihilation spectroscopy measurements. The work shows that the study of the positronium formed when a positron is implanted into the porous surface provides valuable information on the pore distribution and open pore interconnectivity, which suggests that positron annihilation spectroscopy is a useful tool in the porous silicon micropores' characterization

  11. Mapping chemical elements on the surface of orthodontic appliance by SEM-EDX.

    Science.gov (United States)

    Mikulewicz, Marcin; Wołowiec, Paulina; Michalak, Izabela; Chojnacka, Katarzyna; Czopor, Wojciech; Berniczei-Royko, Adam; Vegh, Andras; Gedrange, Thomas

    2014-05-25

    During orthodontic treatment, the various elements that constitute the fixed appliance undergo different processes. As a result of a change of the surface, elution/coverage of metals on the surface can be observed in the process of corrosion/passivation. Scanning electron microscopy with an energy-dispersive X-ray analytical system (SEM-EDX) was used to analyze the composition of stainless steel elements of orthodontic fixed appliances (before and after orthodontic treatment), to obtain the composition of the surface of the elements. The analyzed elements were: brackets (Victory Series APC PLUS 022, 3M Unitek, Monrovia, CA, USA); wires (0.017×0.025, 3M Unitek, Monrovia, CA, USA); and bands (37+, 3M Unitek, Monrovia, CA, USA). The results showed a decrease of chromium and iron contribution to the surface, with increase of oxygen content in used vs. new elements of the appliance. Our results confirm the formation of oxides (passivation layer) on the surface of stainless steel as a result of the presence of the orthodontic appliance in patients' oral cavities.

  12. Incorporating Latent Variables into Discrete Choice Models - A Simultaneous Estimation Approach Using SEM Software

    Directory of Open Access Journals (Sweden)

    Dirk Temme

    2008-12-01

    Full Text Available Integrated choice and latent variable (ICLV models represent a promising new class of models which merge classic choice models with the structural equation approach (SEM for latent variables. Despite their conceptual appeal, applications of ICLV models in marketing remain rare. We extend previous ICLV applications by first estimating a multinomial choice model and, second, by estimating hierarchical relations between latent variables. An empirical study on travel mode choice clearly demonstrates the value of ICLV models to enhance the understanding of choice processes. In addition to the usually studied directly observable variables such as travel time, we show how abstract motivations such as power and hedonism as well as attitudes such as a desire for flexibility impact on travel mode choice. Furthermore, we show that it is possible to estimate such a complex ICLV model with the widely available structural equation modeling package Mplus. This finding is likely to encourage more widespread application of this appealing model class in the marketing field.

  13. Treatment of dentin with stannous fluoride - SEM and electron microprobe study

    International Nuclear Information System (INIS)

    Ellingsen, J.E.; Roella, G.

    1987-01-01

    The effect of SnF 2 -treatment of dentin surfaces was investigated by means of scanning electron microscopy (SEM) and electron microprobe analysis. Human dentin was treated with aqueous SnF 2 solutions of concentrations varying from 1 to 10%. The treatment periods lasted for 1, 5, 10 or 60 min. Both tin and fluoride were identified on the surfaces. The concentration varied depending on the extensiveness of the treatment. Immersion in 1 M KOH for 15 h removed both tin and fluoride from the surfaces. This reaction was not observed after immersion in H 2 O for the same time period. Examination of the SnF 2 -treated dentin surfaces showed a dense layer of globular particles and in addition some larger particles. The dentinal tubules were totally covered even after the treatment with the lowest concentration of SnF 2 . Deposition of tin- and fluoride-containing globules on dentin surfaces may be of clinical interest. This layer may have importance both for the caries resistance of dentin and for hypersensitivity reactions. (author)

  14. A study of equilibrium and FTIR, SEM/EDS analysis of trimethoprim adsorption onto K10

    Science.gov (United States)

    Bekçi, Zehra; Seki, Yoldaş; Kadir Yurdakoç, M.

    2007-02-01

    The sorption behavior of K10, a type of montmorillonite for trimethoprim (TMP) drug, was studied by using batch technique under different pH and temperature. The interaction between K10 and TMP was investigated using SEM, and FTIR. It was observed that adsorption was increased between pH 2.5 and 6.3. By performing kinetic experiments, the pseudo-second-order kinetic model provides the best fit for TMP adsorption onto K10 montmorillonite. The sorption of TMP reached the equilibrium state after 6 h sorption time and has been described by using Langmuir, Freundlich and Dubinin-Radushkevich equations to obtain adsorption capacity values. The results indicate that the relative adsorption capacity values ( Kf) are decreasing with the increase of temperature in the range of 298-318 K. The sorption energy values obtained from DR isotherm show that sorption of TMP onto K10 can be explained by ion exchange mechanism at 298, 308 and 318 K. The thermodynamic studies were conducted to find the thermodynamic parameters Δ H°, Δ S° and Δ G°. It was determined that adsorption process is spontaneous and exothermic in nature.

  15. Synthetic tooth enamel: SEM characterization of a fluoride hydroxyapatite coating for dentistry applications

    Directory of Open Access Journals (Sweden)

    Marise Oliveira

    2007-06-01

    Full Text Available An alternative to etching enamel for retention of an adhesive is to grow crystals on the enamel surface. The potential advantages of crystal growth include easy procedure and less damage to the enamel. These crystals retain the adhesive or are the actual dental restoration. In this work, a paste of synthetic enamel was used to grow crystals of fluoride hydroxyapatite (F-HA onto the human tooth surface. This technique can be used for several dentistry applications like enamel whitening, strengthening and restoration of early carie lesions. The low cost of reagents and simplicity of the technique along with the biocompatibility of the paste render possible the utilization on the market. The samples were prepared through the application of the paste by the incremental technique. The results obtained by scanning electron microscope (SEM/EDX have indicated the deposition of a homogeneous layer of calcium phosphate that was grown onto the enamel substrate. The average thickness of the deposited film was in the range of 50-100 µm and with a similar density from the natural enamel observed by radiographic images.

  16. Characterization of mineral particles in winter fog of Beijing analyzed by TEM and SEM.

    Science.gov (United States)

    Li, Weijun; Shao, Longyi

    2010-02-01

    Aerosol samples were collected during winter fog and nonfog episodes in Beijing. Transmission electron microscopy (TEM) and scanning electron microscopy (SEM) were applied to study morphologies, sizes, and compositions of aerosol particles. TEM observation indicates that most mineral particles collected in fog episode are scavenged in fog droplets. Number-size distributions of mineral particles collected in fog and nonfog episodes show two main peaks at the ranges of 0.1-0.3 and 1-2.5 microm, respectively. Based on their major compositions, mineral particles mainly include Si-rich, Ca-rich, and S-rich. Average S/Ca ratio of mineral particles collected in fog episode is 6.11, being eight times higher than that in nonfog episodes. Development mechanism of individual mineral particles in fog droplets is proposed. It is suggested that mineral particles with abundant alkaline components (e.g., "Ca-rich" particles) occurred in air should alleviate acidic degree of fog and contribute to complexity of fog droplets in Beijing.

  17. SEM corrosion-casts study of the microcirculation of the flat bones in the rat.

    Science.gov (United States)

    Pannarale, L; Morini, S; D'Ubaldo, E; Gaudio, E; Marinozzi, G

    1997-04-01

    Little is known about the organization of microcirculation in flat bones in comparison with long bones. This study, therefore, helps us to determine the design of this vascular system in flat bones in relation to their structure and function. The organization of microvasculature in parietal, scapula, and ileum bones of 15 young sexually mature rats, aged 6-7 weeks, was studied by light and scanning electron microscopy (SEM) from vascular corrosion cast (vcc), a resin-cast obtained material. Our observations show that the pattern of the microcirculation in flat bones is different in the thick and thin parts of such bones. Where the bone is thinner than 0.4 mm, only periosteal and dural network exist. Larger vessels which do not form a real network connect the two tables of the bones in these regions. In thicker areas, the organization of the microvasculature is similar to that in long bones, with distinct periosteal, cortical and bone marrow networks. Moreover, in different bones, outer networks show slightly different characteristics according to the different adjacent structures (dura mater, muscles etc.). Different types of vessels were recognized by comparing their different diameter, course and endothelial imprints. The microvascular patterns of the flat bones are strongly influenced by the bone thickness. The different microvascular systems can interact both with the bone modelling and remodeling and with the variable metabolic needs, modifying the microvascular pattern and the blood flow. This is even more important in view of the reciprocal influence of the different networks within the same bone.

  18. SEM Characterization of the High Burn-up Microstructure of U-7Mo Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Dennis D. Keiser, Jr.; Jan-Fong Jue; Jian Gan; Brandon Miller; Adam Robinson; Pavel Medvedev; James Madden; Dan Wachs; M. Teague

    2014-04-01

    During irradiation, the microstructure of U-7Mo evolves until at a fission density near 5x1021 f/cm3 a high-burnup microstructure exists that is very different than what was observed at lower fission densities. This microstructure is dominated by randomly distributed, relatively large, homogeneous fission gas bubbles. The bubble superlattice has collapsed in many microstructural regions, and the fuel grain sizes, in many areas, become sub-micron in diameter with both amorphous fuel and crystalline fuel present. Solid fission product precipitates can be found inside the fission gas bubbles. To generate more information about the characteristics of the high-fission density microstructure, three samples irradiated in the RERTR-7 experiment have been characterized using a scanning electron microscope equipped with a focused ion beam. The FIB was used to generate samples for SEM imaging and to perform 3D reconstruction of the microstructure, which can be used to look for evidence of possible fission gas bubble interlinkage.

  19. In-line CD metrology with combined use of scatterometry and CD-SEM

    Science.gov (United States)

    Asano, Masafumi; Ikeda, Takahiro; Koike, Toru; Abe, Hideaki

    2006-03-01

    Measurement characteristics in scatterometry and CD-SEM for lot acceptance sampling of inline critical dimension (CD) metrology were investigated by using a statistical approach with Monte Carlo simulation. By operation characteristics curve analysis, producer's risk and consumer's risk arising from sampling were clarified. Single use of scatterometry involves a higher risk, such risk being particularly acute in the case of large intra-chip CD variation because it is unable to sufficiently monitor intra-chip CD variation including local CD error. Substituting scatterometry for conventional SEM metrology is accompanied with risks, resulting in the increase of unnecessary cost. The combined use of scatterometry and SEM metrology in which the sampling plan for SEM is controlled by scatterometry is a promising metrology from the viewpoint of the suppression of risks and cost. This is due to the effect that CD errors existing in the distribution tails are efficiently caught.

  20. Mathematical model of the seismic electromagnetic signals (SEMS) in non crystalline substances

    Energy Technology Data Exchange (ETDEWEB)

    Dennis, L. C. C.; Yahya, N.; Daud, H.; Shafie, A. [Electromagnetic cluster, Universiti Teknologi Petronas, 31750 Tronoh, Perak (Malaysia)

    2012-09-26

    The mathematical model of seismic electromagnetic waves in non crystalline substances is developed and the solutions are discussed to show the possibility of improving the electromagnetic waves especially the electric field. The shear stress of the medium in fourth order tensor gives the equation of motion. Analytic methods are selected for the solutions written in Hansen vector form. From the simulated SEMS, the frequency of seismic waves has significant effects to the SEMS propagating characteristics. EM waves transform into SEMS or energized seismic waves. Traveling distance increases once the frequency of the seismic waves increases from 100% to 1000%. SEMS with greater seismic frequency will give seismic alike waves but greater energy is embedded by EM waves and hence further distance the waves travel.

  1. SEM-668-G2(日东科技)

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    SEM-668-G2比SEM-668在视觉技术上更加精湛,采用美国AGILENT(安提伦)LASER 5519A及HP的双重频率技术,加强运动;隹确性。在智能化印刷头上,SEM-668-G2印刷质量更加均匀、稳定,操作界面更加简易、更加人性化。在综合性能上更加卓越,保证实现现代化的生产效率。产品体具性能如下:SEM-668-G2视觉全自动印刷机

  2. Mathematical model of the seismic electromagnetic signals (SEMS) in non crystalline substances

    International Nuclear Information System (INIS)

    Dennis, L. C. C.; Yahya, N.; Daud, H.; Shafie, A.

    2012-01-01

    The mathematical model of seismic electromagnetic waves in non crystalline substances is developed and the solutions are discussed to show the possibility of improving the electromagnetic waves especially the electric field. The shear stress of the medium in fourth order tensor gives the equation of motion. Analytic methods are selected for the solutions written in Hansen vector form. From the simulated SEMS, the frequency of seismic waves has significant effects to the SEMS propagating characteristics. EM waves transform into SEMS or energized seismic waves. Traveling distance increases once the frequency of the seismic waves increases from 100% to 1000%. SEMS with greater seismic frequency will give seismic alike waves but greater energy is embedded by EM waves and hence further distance the waves travel.

  3. Assessment of Paint Layers by FE-SEM and EDS Examination

    National Research Council Canada - National Science Library

    Harris, Donovan

    2004-01-01

    .... The approach was to remove free-film samples from each panel, fracture the films, and then examine at high magnification the cross sections using a field emission-scanning electron microscope (FE-SEM...

  4. Corrigendum to: Bayesian evaluation of informative hypotheses in SEM using Mplus

    NARCIS (Netherlands)

    van de Schoot, R.; Verhoeven, Marjolein; Hoijtink, H.

    2014-01-01

    This paper corrects: van de Schoot, R., Verhoeven, M., & Hoijtink, H. (2013). Bayesian evaluation ofinformative hypotheses in SEM using Mplus: A black bear story. EuropeanJournal of Developmental Psychology, 10, 81 –98.

  5. Automated CD-SEM recipe creation technology for mass production using CAD data

    Science.gov (United States)

    Kawahara, Toshikazu; Yoshida, Masamichi; Tanaka, Masashi; Ido, Sanyu; Nakano, Hiroyuki; Adachi, Naokaka; Abe, Yuichi; Nagatomo, Wataru

    2011-03-01

    Critical Dimension Scanning Electron Microscope (CD-SEM) recipe creation needs sample preparation necessary for matching pattern registration, and recipe creation on CD-SEM using the sample, which hinders the reduction in test production cost and time in semiconductor manufacturing factories. From the perspective of cost reduction and improvement of the test production efficiency, automated CD-SEM recipe creation without the sample preparation and the manual operation has been important in the production lines. For the automated CD-SEM recipe creation, we have introduced RecipeDirector (RD) that enables the recipe creation by using Computer-Aided Design (CAD) data and text data that includes measurement information. We have developed a system that automatically creates the CAD data and the text data necessary for the recipe creation on RD; and, for the elimination of the manual operation, we have enhanced RD so that all measurement information can be specified in the text data. As a result, we have established an automated CD-SEM recipe creation system without the sample preparation and the manual operation. For the introduction of the CD-SEM recipe creation system using RD to the production lines, the accuracy of the pattern matching was an issue. The shape of design templates for the matching created from the CAD data was different from that of SEM images in vision. Thus, a development of robust pattern matching algorithm that considers the shape difference was needed. The addition of image processing of the templates for the matching and shape processing of the CAD patterns in the lower layer has enabled the robust pattern matching. This paper describes the automated CD-SEM recipe creation technology for the production lines without the sample preparation and the manual operation using RD applied in Sony Semiconductor Kyusyu Corporation Kumamoto Technology Center (SCK Corporation Kumamoto TEC).

  6. Understanding the Online : Jewellery Retail Market : an integrated model to conduct SEM

    OpenAIRE

    Wu, Yihong

    2013-01-01

    Research into e-commerce is becoming more and more popular; however the jewellery industry is somewhat special. There are very few studies having adapted a strategic marketing perspective on the online jewellery retail market. This study suggested an integrated online marketing strategy which focuses on the search engine marketing (SEM) approach. A detailed procedure of conducting search engine marketing (SEM) is introduced. Through the method of online questionnaires, with the help of soc...

  7. How Hedstrom files fail during clinical use? A retrieval study based on SEM, optical microscopy and micro-XCT analysis.

    Science.gov (United States)

    Zinelis, Spiros; Al Jabbari, Youssef S

    2018-05-01

    This study was conducted to evaluate the failure mechanism of clinically failed Hedstrom (H)-files. Discarded H-files (n=160) from #8 to #40 ISO sizes were collected from different dental clinics. Retrieved files were classified according to their macroscopic appearance and they were investigated under scanning electron microscopy (SEM) and X-ray micro-computed tomography (mXCT). Then the files were embedded in resin along their longitudinal axis and after metallographic grinding and polishing, studied under an incident light microscope. The macroscopic evaluation showed that small ISO sizes (#08-#15) failed by extensive plastic deformation, while larger sizes (≥#20) tended to fracture. Light microscopy and mXCT results coincided showing that unused and plastically deformed files were free of internal defects, while fractured files demonstrate the presence of intense cracking in the flute region. SEM analysis revealed the presence of striations attributed to the fatigue mechanism. Secondary cracks were also identified by optical microscopy and their distribution was correlated to fatigue under bending loading. Experimental results demonstrated that while overloading of cutting instruments is the predominating failure mechanism of small file sizes (#08-#15), fatigue should be considered the fracture mechanism for larger sizes (≥#20).

  8. The relationship between cost estimates reliability and BIM adoption: SEM analysis

    Science.gov (United States)

    Ismail, N. A. A.; Idris, N. H.; Ramli, H.; Rooshdi, R. R. Raja Muhammad; Sahamir, S. R.

    2018-02-01

    This paper presents the usage of Structural Equation Modelling (SEM) approach in analysing the effects of Building Information Modelling (BIM) technology adoption in improving the reliability of cost estimates. Based on the questionnaire survey results, SEM analysis using SPSS-AMOS application examined the relationships between BIM-improved information and cost estimates reliability factors, leading to BIM technology adoption. Six hypotheses were established prior to SEM analysis employing two types of SEM models, namely the Confirmatory Factor Analysis (CFA) model and full structural model. The SEM models were then validated through the assessment on their uni-dimensionality, validity, reliability, and fitness index, in line with the hypotheses tested. The final SEM model fit measures are: P-value=0.000, RMSEA=0.0790.90, TLI=0.956>0.90, NFI=0.935>0.90 and ChiSq/df=2.259; indicating that the overall index values achieved the required level of model fitness. The model supports all the hypotheses evaluated, confirming that all relationship exists amongst the constructs are positive and significant. Ultimately, the analysis verified that most of the respondents foresee better understanding of project input information through BIM visualization, its reliable database and coordinated data, in developing more reliable cost estimates. They also perceive to accelerate their cost estimating task through BIM adoption.

  9. Raman-in-SEM, a multimodal and multiscale analytical tool: performance for materials and expertise.

    Science.gov (United States)

    Wille, Guillaume; Bourrat, Xavier; Maubec, Nicolas; Lahfid, Abdeltif

    2014-12-01

    The availability of Raman spectroscopy in a powerful analytical scanning electron microscope (SEM) allows morphological, elemental, chemical, physical and electronic analysis without moving the sample between instruments. This paper documents the metrological performance of the SEMSCA commercial Raman interface operated in a low vacuum SEM. It provides multiscale and multimodal analyses as Raman/EDS, Raman/cathodoluminescence or Raman/STEM (STEM: scanning transmission electron microscopy) as well as Raman spectroscopy on nanomaterials. Since Raman spectroscopy in a SEM can be influenced by several SEM-related phenomena, this paper firstly presents a comparison of this new tool with a conventional micro-Raman spectrometer. Then, some possible artefacts are documented, which are due to the impact of electron beam-induced contamination or cathodoluminescence contribution to the Raman spectra, especially with geological samples. These effects are easily overcome by changing or adapting the Raman spectrometer and the SEM settings and methodology. The deletion of the adverse effect of cathodoluminescence is solved by using a SEM beam shutter during Raman acquisition. In contrast, this interface provides the ability to record the cathodoluminescence (CL) spectrum of a phase. In a second part, this study highlights the interest and efficiency of the coupling in characterizing micrometric phases at the same point. This multimodal approach is illustrated with various issues encountered in geosciences. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Feature evaluation of complex hysteresis smoothing and its practical applications to noisy SEM images.

    Science.gov (United States)

    Suzuki, Kazuhiko; Oho, Eisaku

    2013-01-01

    Quality of a scanning electron microscopy (SEM) image is strongly influenced by noise. This is a fundamental drawback of the SEM instrument. Complex hysteresis smoothing (CHS) has been previously developed for noise removal of SEM images. This noise removal is performed by monitoring and processing properly the amplitude of the SEM signal. As it stands now, CHS may not be so utilized, though it has several advantages for SEM. For example, the resolution of image processed by CHS is basically equal to that of the original image. In order to find wide application of the CHS method in microscopy, the feature of CHS, which has not been so clarified until now is evaluated correctly. As the application of the result obtained by the feature evaluation, cursor width (CW), which is the sole processing parameter of CHS, is determined more properly using standard deviation of noise Nσ. In addition, disadvantage that CHS cannot remove the noise with excessively large amplitude is improved by a certain postprocessing. CHS is successfully applicable to SEM images with various noise amplitudes. © Wiley Periodicals, Inc.

  11. Effect of reciprocating file motion on microcrack formation in root canals: an SEM study.

    Science.gov (United States)

    Ashwinkumar, V; Krithikadatta, J; Surendran, S; Velmurugan, N

    2014-07-01

    To compare dentinal microcrack formation whilst using Ni-Ti hand K-files, ProTaper hand and rotary files and the WaveOne reciprocating file. One hundred and fifty mandibular first molars were selected. Thirty teeth were left unprepared and served as controls, and the remaining 120 teeth were divided into four groups. Ni-Ti hand K-files, ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files were used to prepare the mesial canals. Roots were then sectioned 3, 6 and 9 mm from the apex, and the cut surface was observed under scanning electron microscope (SEM) and checked for the presence of dentinal microcracks. The control and Ni-Ti hand K-files groups were not associated with microcracks. In roots prepared with ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files, dentinal microcracks were present. There was a significant difference between control/Ni-Ti hand K-files group and ProTaper hand files/ProTaper rotary files/WaveOne Primary reciprocating file group (P ProTaper rotary files producing the most microcracks. No significant difference was observed between teeth prepared with ProTaper hand files and WaveOne Primary reciprocating files. ProTaper rotary files were associated with significantly more microcracks than ProTaper hand files and WaveOne Primary reciprocating files. Ni-Ti hand K-files did not produce microcracks at any levels inside the root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  12. Antagonistic effects of Bacillus subtilis subsp. subtilis and B. amyloliquefaciens against Macrophomina phaseolina: SEM study of fungal changes and UV-MALDI-TOF MS analysis of their bioactive compounds.

    Science.gov (United States)

    Torres, M J; Brandan, C Pérez; Petroselli, G; Erra-Balsells, R; Audisio, M C

    2016-01-01

    The antifungal effect of Bacillus subtilis subsp. subtilis PGPMori7 and Bacillus amyloliquefaciens PGPBacCA1 was evaluated against Macrophomina phaseolina (Tassi) Goid. Cell suspension (CS), cell-free supernatant (CFS) and the lipopeptide fraction (LF) of PGPMori7 and PGPBacCA1 were screened against three different M. phaseolina strains. CS exhibited the highest inhibitory effect (around 50%) when compared to those of CFS and LF, regardless of the fungal strain studied. The synthesis of lipopeptides was studied by UV-MALDI TOF. Chemical analysis of Bacillus metabolite synthesis revealed that surfactin and iturin were mainly produced in liquid medium. Potential fengycin was also co-produced when both Bacillus were cultivated in solid medium. In co-culture assays, the bacterial colony-fungal mycelium interface at the inhibition zone was evaluated by both scanning electron microscopy (SEM) and UV-MALDI TOF, the former to determine the structural changes on M. phaseolina cells and the latter to identify the main bioactive molecules involved in the inhibitory effect. PGPBacCA1 produced surfactin, iturin and fengycin in the inhibition zone while PGPMori7 only produced these metabolites within its colony and not in the narrow inhibition zone. Interestingly, SEM revealed that PGPBacCA1 induced damage in M. phaseolina sclerotia, generating a fungicidal effect as no growth was observed when normal growth conditions were reestablished. In turn, PGPMori7 inhibited the growth of the Macrophomina mycelium without fungal injury, resulting only in a fungistatic activity. From these results, it was determined that the two bacilli significantly inhibited the growth of an important phytopathogenic fungus by at least two different mechanisms: lipopeptide synthesis and competition among microorganisms. Copyright © 2015 Elsevier GmbH. All rights reserved.

  13. Evaluating the Effects of Metals on Microorganisms in Flooded Paddy Soils Using the SEM/AVS-Based Approach and Measurements of Exchangeable Metal Concentrations.

    Science.gov (United States)

    Kunito, Takashi; Toya, Hitomi; Sumi, Hirotaka; Ishikawa, Yuichi; Toda, Hideshige; Nagaoka, Kazunari; Saeki, Kazutoshi; Aikawa, Yoshio; Matsumoto, Satoshi

    2017-04-01

    We examined possible adverse effects of heavy metals on microbial activity, biomass, and community composition using the simultaneously extracted metals (SEM)/acid-volatile sulfide (AVS)-based approach and measurements of exchangeable metal concentrations in three paddy soils (wastewater-contaminated soil, mine-contaminated soil, and noncontaminated soil) incubated for 60 days under flooded conditions. Incubation under flooding increased pH and decreased Eh in all samples. AVS increased when Eh decreased to approximately -200 mV for the mine-contaminated and noncontaminated soils, while the wastewater-contaminated soil originally had a high concentration of AVS despite its air-dried condition. Addition of rice straw or alkaline material containing calcium carbonate and gypsum increased AVS levels under flooded conditions. We observed no apparent relationship between soil enzyme activity (β-D-glucosidase and acid phosphatase) and concentrations of SEM, [∑SEM - AVS], and exchangeable metals. Bacterial and fungal community composition, assessed using polymerase chain reaction-denaturing gradient gel electrophoresis (DGGE) analysis targeting rRNA genes, was largely influenced by site of collection and incubation time, but metal contamination did not influence community composition. We observed significant negative correlations between biomass C and [∑SEM - AVS] and between biomass C and ∑SEM, suggesting that [∑SEM - AVS] and ∑SEM might reflect the bioavailability of organic matter to microorganisms in these soils.

  14. SEM Leadership

    Science.gov (United States)

    Pollock, Kevin

    2012-01-01

    Expectations of higher education leaders are high, varied, and numerous. Leaders are expected not only to be visionary, decisive, and articulate, but also to share information, purposes, commitments, and struggles. Effective leaders must know and understand their faculty and staff; insist on realism; set clear goals and priorities; follow through;…

  15. The Effectiveness of Self-Expandable Metallic Stent Insertion in Treating Right-Sided Colonic Obstruction: A Comparison between SEMS and Decompression Tube Placement and an Investigation of the Safety and Difficulties of SEMS Insertion in Right Colons

    Directory of Open Access Journals (Sweden)

    Rintaro Moroi

    2014-01-01

    Full Text Available Objectives. Self-expandable metallic stent (SEMS is widely used to treat malignant colonic obstruction. However, most reports about SEMS insertion have concentrated on the left colon. This study aimed to (1 investigate the effectiveness of SEMS insertion compared with conventional decompression tube for right-sided colonic obstruction and (2 compare the safety and technical success of SEMS insertion between left- and right-sided colonic obstructions. Methods. The data from thirty-seven patients who underwent SEMS or conventional decompression tube placement for malignant colonic obstruction in our hospital were analyzed retrospectively. Technical and clinical success, complications, and technical difficulties were analyzed. We compared the results between SEMS insertion and decompression tube placement in right colons and the outcomes of SEMS insertion between right- and left-sided colonic obstructions. Results. For right colons, the clinical success rate of SEMS insertion (100% was significantly higher than that of decompression tube placement (55.9%. Concerning SEMS insertion, the technical difficulty and safety of SEMS insertion were similar between right- and left-sided colonic obstructions. Conclusion. SEMS insertion for right-sided colon is significantly more effective than conventional decompression tube placement, and this procedure was safer and less technically challenging than expected. SEMS insertion should be considered for treating right-sided malignant colonic obstruction.

  16. A combined SEM, CV and EIS study of multi-layered porous ceramic reactors for flue gas purification

    DEFF Research Database (Denmark)

    He, Zeming; Andersen, Kjeld Bøhm; Nygaard, Frederik Berg

    2013-01-01

    The effect of sintering temperature of 12-layered porous ceramic reactors (comprising 5 cells) was studied using scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The difference in microstructures of the reactors was evaluated by SEM...

  17. Smear layer removal capacity of disinfectant solutions used with and without EDTA for the irrigation of canals: a SEM study

    Directory of Open Access Journals (Sweden)

    Menezes Ana Carolina Silveira Cardoso de

    2003-01-01

    Full Text Available The purpose of this study was to carry out a scanning electron microscopic (SEM analysis of the cleaning qualities and smear layer removal from root canal walls, instrumented and irrigated with 2.5% NaOCl, 2.0% chlorhexidine and saline solutions. Fifty extracted teeth were used in this study. All teeth were radiographed to determine the existence of a single canal. The crowns were cut at the cervical limit and the root canals were instrumented with K-type files up to size 45. During root canal preparation, irrigations were made with the different solutions being evaluated: Group 1: 2.5% NaOCl (10 roots; Group 2: 2.5% NaOCl and 17% EDTA for 2 minute (10 roots; Group 3: 2.0% chlorhexidine (10 roots; Group 4: 2.0% chlorhexidine and 17% EDTA for 2 minutes (10 roots; Group 5: saline solution (5 roots; Group 6: saline solution and 17% EDTA for 2 minutes (5 roots. After instrumentation, the canals were irrigated with each one of the solutions and the roots were cut in the buccolingual direction for SEM analysis, at the cervical, middle and apical thirds, to ascertain the presence or absence of smear layer and debris. SEM analysis was performed by three calibrated examiners and scores were submitted to Kruskal-Wallis test at the significance level of p = 5%. Results showed that the use of 17% EDTA decreased the smear layer significantly (p < 0.05 for all evaluated solutions in all thirds. When EDTA was not used, a significantly higher quantity of smear layer on the apical third was observed only in the NaOCl groups. The use of 17% EDTA was significant for debris removal except for the chlorhexidine groups. The following conclusion could be drawn: the use of 17% EDTA was necessary to enhance cleanness of the root canals.

  18. In-situ SEM microchip setup for electrochemical experiments with water based solutions

    International Nuclear Information System (INIS)

    Jensen, E.; Købler, C.; Jensen, P.S.; Mølhave, K.

    2013-01-01

    Studying electrochemical (EC) processes with electron microscopes offers the possibility of achieving much higher resolution imaging of nanoscale processes in real time than with optical microscopes. We have developed a vacuum sealed liquid sample electrochemical cell with electron transparent windows, microelectrodes and an electrochemical reference electrode. The system, called the EC-SEM Cell, is used to study electrochemical reactions in liquid with a standard scanning electron microscope (SEM). The central component is a microfabricated chip with a thin (50 nm) Si-rich silicon nitride (SiNx) window with lithographically defined platinum microelectrodes. We show here the design principles of the EC-SEM system, its detailed construction and how it has been used to perform a range of EC experiments, two of which are presented here. It is shown that the EC-SEM Cell can survive extended in-situ EC experiments. Before the EC experiments we characterized the beam current being deposited in the liquid as this will affect the experiments. The first EC experiment shows the influence of the electron-beam (e-beam) on a nickel solution by inducing electroless nickel deposition on the window when increasing the current density from the e-beam. The second experiment shows electrolysis in EC-SEM Cell, induced by the built-in electrodes. - Highlights: • New in-situ SEM system for electrochemistry. • In-situ Beam current measurements through liquid. • In-situ SEM E-beam-induced electroless deposition of Ni. • In-situ electrolysis

  19. In-situ SEM microchip setup for electrochemical experiments with water based solutions

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, E., E-mail: eric.jensen@nanotech.dtu.dk [DTU Nanotech, Technical University of Denmark, Ørsteds Plads, Building 345E, 2800 Kongens Lyngby (Denmark); DTU CEN, Technical University of Denmark, Fysikvej, Building 307, 2800 Kongens Lyngby (Denmark); Købler, C., E-mail: carsten.kobler@nanotech.dtu.dk [DTU Nanotech, Technical University of Denmark, Ørsteds Plads, Building 345E, 2800 Kongens Lyngby (Denmark); DTU CEN, Technical University of Denmark, Fysikvej, Building 307, 2800 Kongens Lyngby (Denmark); Jensen, P.S., E-mail: psj@kemi.dtu.dk [DTU Kemi, Technical University of Denmark, Kemitorvet, Building 207, 2800 Kongens Lyngby (Denmark); Mølhave, K., E-mail: kristian.molhave@nanotech.dtu.dk [DTU Nanotech, Technical University of Denmark, Ørsteds Plads, Building 345E, 2800 Kongens Lyngby (Denmark)

    2013-06-15

    Studying electrochemical (EC) processes with electron microscopes offers the possibility of achieving much higher resolution imaging of nanoscale processes in real time than with optical microscopes. We have developed a vacuum sealed liquid sample electrochemical cell with electron transparent windows, microelectrodes and an electrochemical reference electrode. The system, called the EC-SEM Cell, is used to study electrochemical reactions in liquid with a standard scanning electron microscope (SEM). The central component is a microfabricated chip with a thin (50 nm) Si-rich silicon nitride (SiNx) window with lithographically defined platinum microelectrodes. We show here the design principles of the EC-SEM system, its detailed construction and how it has been used to perform a range of EC experiments, two of which are presented here. It is shown that the EC-SEM Cell can survive extended in-situ EC experiments. Before the EC experiments we characterized the beam current being deposited in the liquid as this will affect the experiments. The first EC experiment shows the influence of the electron-beam (e-beam) on a nickel solution by inducing electroless nickel deposition on the window when increasing the current density from the e-beam. The second experiment shows electrolysis in EC-SEM Cell, induced by the built-in electrodes. - Highlights: • New in-situ SEM system for electrochemistry. • In-situ Beam current measurements through liquid. • In-situ SEM E-beam-induced electroless deposition of Ni. • In-situ electrolysis.

  20. Evaluation of depth of field in SEM images in terms of the information-passing capacity (IPC) and contrast gradient in SEM image

    International Nuclear Information System (INIS)

    Sato, Mitsugu; Ishitani, Tohru; Watanabe, Shunya; Nakagawa, Mine

    2004-01-01

    The depth of field (DoF) in scanning electron microscope (SEM) images has been determined by estimating the change of image sharpness or resolution near the exact focus position. The image sharpness or resolution along the optical axis is determined by calculating the information-passing capacity (IPC) of an optical system taking into account the effect of pixel size of the image. The change of image sharpness near the exact focus position is determined by measuring the slope gradient of the line profile in SEM images obtained at various focal positions of beam. The change of image sharpness along the optical axis determined by the IPC agrees well with those determined by the slope gradient of line profiles in SEM images when a Gaussian distribution having radius 0.86L p (L p : pixel size in image) at which the intensity has fallen to 1/e of the maximum is applied to the IPC calculation for each pixel intensity. The change of image sharpness near the exact focus position has also been compared with those determined by the CG (Contrast-to-Gradient) method. The CG method slightly underestimates the change of image sharpness compared with those determined by the IPC method

  1. Site-selective dopant profiling of p-n junction specimens in the dual-beam FIB/SEM system

    International Nuclear Information System (INIS)

    Chee, K W A; Beanland, R; Midgley, P A; Humphreys, C J

    2010-01-01

    Results from site-specific dopant profiling in a dual-beam FIB/SEM system are reported. Si specimens containing p-n junctions were milled using Ga + ion beam energies ranging from 30 keV to 2 keV, and analysed in situin the vacuum chamber. We compare the dopant contrast observed when milling a cleaved surface to that obtained from a side-wall of a trench cut using 30 kV Ga + ions, and using successively lower ion beam energies. The latter technique is suitable for site-specific dopant profiling. We find that lower energy ion beam milling significantly improves contrast, but only achieves 50 % of that observed on a freshly-cleaved surface. Furthermore, the contrast on a side-wall previously milled using high energy Ga + ions is less than that of a cleaved surface subjected to the same ion beam energy.

  2. Chemistry of plutonium revealed

    International Nuclear Information System (INIS)

    Connick, R.E.

    1992-01-01

    In 1941 one goal of the Manhattan Project was to unravel the chemistry of the synthetic element plutonium as rapidly as possible. In this paper the work carried out at Berkeley from the spring of 1942 to the summer of 1945 is described briefly. The aqueous chemistry of plutonium is quite remarkable. Important insights were obtained from tracer experiments, but the full complexity was not revealed until macroscopic amounts (milligrams) became available. Because processes for separation from fission products were based on aqueous solutions, such solution chemistry was emphasized, particularly precipitation and oxidation-reduction behavior. The latter turned out to be unusually intricate when it was discovered that two more oxidation states existed in aqueous solution than had previously been suspected. Further, an equilibrium was rapidly established among the four aqueous oxidation states, while at the same time any three were not in equilibrium. These and other observations made while doing a crash study of a previously unknown element are reported

  3. Experimental investigation on 3D-SEM reconstructions of a wire gauge using stereo-pair technique

    DEFF Research Database (Denmark)

    Carli, Lorenzo; Genta, G.; Cantatore, Angela

    2011-01-01

    In this work an experimental investigation is addressed concerning 3D-SEM reconstructions obtained from the so-called stereo-pair technique. Three-dimensional topography of an object can be derived from two SEM images acquired from two different angles, through item rotation by means of the SEM...

  4. A Teoria dos Blocos Semânticos em revisão

    Directory of Open Access Journals (Sweden)

    Julio Cesar Machado

    2017-08-01

    Full Text Available A Teoria dos Blocos Semânticos ocupa lugar significativo nos trabalhos mundiais em Semântica, Argumentação e Enunciação, dentre outros. Por isso sua pertinência para a Linguística reclama uma reflexão. O presente trabalho pretende refletir algumas reformulações na Teoria dos Blocos Semânticos nas últimas duas décadas, a saber: (a polifonia, (b bloco semântico, e (c quadrado argumentativo. Especificamente, trataremos das seguintes relações: (a’ da Teoria Polifônica da Enunciação à Teoria Argumentativa da Polifonia; (b’ do bloco semântico ao semi-bloco; e (c’ do quadrado argumentativo ao cubo argumentativo. A necessidade deste trabalho é duplamente justificada: (i devido à constante revisão teórica do arcabouço teórico deste saber, sobretudo na sua última década, característica de Marion Carel e de Oswald Ducrot; e (ii pela falta de tradução/circulação no Brasil de obras fundamentais no que tange à re-elaboração das noções chaves desta teoria.

  5. SEM-REV: A sea test site for Marine Energy Converter

    International Nuclear Information System (INIS)

    Berhault, Christian; Le Crom, Izan; Le Bihan, Gerard

    2015-01-01

    Thanks to a main funding of Region des Pays de la Loire, the sea test site SEM-REV has been developed by Ecole Centrale de Nantes since 2007 to test both Wave Energy Converters and Floating Wind Turbine in real sea conditions. The sea test site is equipped with a set of oceanographic sensors and with an electric cable of 8 MW, connected to the French grid. The project is located close to Le Croisic, Western coast of France. SEM-REV is one of the main test facilities operated by Ecole Centrale de Nantes to support MRE technologies development. After presenting the initial motivations of the SEM-REV development, the paper describes, in parts 1 and 2, the complete administrative and technical processes that were followed to reach SEM-REV commissioning in 2014. The third part is focused on the exploitation process, including technical and contractual specifications imposed to the MRE developers for installation, tests and decommissioning phases. Some words are given also on the R and D projects using the SEM-REV in-situ monitoring system: prediction of environmental conditions, bio-fooling, acoustic impact. Even if operational phase is not started, expected extensions of the tests site are listed. (authors)

  6. The use of SEM/EDS method in mineralogical analysis of ordinary chondritic meteorite

    Directory of Open Access Journals (Sweden)

    Breda Mirtič

    2009-12-01

    Full Text Available The aim of this study was to evaluate the potential of scanning electron microscopy coupled with energy dispersiveX-ray spectroscopy (SEM/EDS for determination of mineral phases according to their stoichiometry and assessment of mineral composition of ordinary chondritic meteorite. For the purposes of this study, H3 type ordinary chondritic meteorite Abbott was selected. SEM/EDS allows identification and characterisation of mineralphases, whose size is below the resolution of an optical microscope. Mineral phases in chondrules and interstitial matrix were located in backscattered electron (BSE mode and were assessed from atomic proportions of constituent elements, obtained by the EDS analysis. SEM/EDS analyses of mineral phases showed that Abbott meteorite is characterised by Fe-rich (Fe, Ni-alloy kamacite, Fe-sulphide troilite or pyrrhotite, chromite, Mg-rich olivine, orthopyroxene bronzite or hypersthene, clinopyroxene Al-diopside, acid plagioclase oligoclase, accessory mineral chlorapatite and secondary minerals Fe-hydroxides (goethite or lepidocrocite. Results of semi-quantitative analyses confirmed that most of analysed mineralphases conform well to stoichiometric minerals with minor deviations of oxygen from stoichiometric proportions. Comparison between mineral phases in chondrules and interstitial matrix was also performed, however it showed no significant differences in elemental composition.Differences in chemical composition between minerals in interstitial matrix and chondrules are sometimes too small to be discernedby the SEM/EDS, therefore knowledge of SEM/EDS capabilities is important for correct interpretation of chondrite formation.

  7. In Situ Characterization of Boehmite Particles in Water Using Liquid SEM.

    Science.gov (United States)

    Yao, Juan; Arey, Bruce W; Yang, Li; Zhang, Fei; Komorek, Rachel; Chun, Jaehun; Yu, Xiao-Ying

    2017-09-27

    In situ imaging and elemental analysis of boehmite (AlOOH) particles in water is realized using the System for Analysis at the Liquid Vacuum Interface (SALVI) and Scanning Electron Microscopy (SEM). This paper describes the method and key steps in integrating the vacuum compatible SAVLI to SEM and obtaining secondary electron (SE) images of particles in liquid in high vacuum. Energy dispersive x-ray spectroscopy (EDX) is used to obtain elemental analysis of particles in liquid and control samples including deionized (DI) water only and an empty channel as well. Synthesized boehmite (AlOOH) particles suspended in liquid are used as a model in the liquid SEM illustration. The results demonstrate that the particles can be imaged in the SE mode with good resolution (i.e., 400 nm). The AlOOH EDX spectrum shows significant signal from the aluminum (Al) when compared with the DI water and the empty channel control. In situ liquid SEM is a powerful technique to study particles in liquid with many exciting applications. This procedure aims to provide technical know-how in order to conduct liquid SEM imaging and EDX analysis using SALVI and to reduce potential pitfalls when using this approach.

  8. Surgery on spinal epidural metastases (SEM) in renal cell carcinoma: a plea for a new paradigm.

    Science.gov (United States)

    Bakker, Nicolaas A; Coppes, Maarten H; Vergeer, Rob A; Kuijlen, Jos M A; Groen, Rob J M

    2014-09-01

    Prediction models for outcome of decompressive surgical resection of spinal epidural metastases (SEM) have in common that they have been developed for all types of SEM, irrespective of the type of primary tumor. It is our experience in clinical practice, however, that these models often fail to accurately predict outcome in the individual patient. To investigate whether decision making could be optimized by applying tumor-specific prediction models. For the proof of concept, we analyzed patients with SEM from renal cell carcinoma that we have operated on. Retrospective chart analysis 2006 to 2012. Twenty-one consecutive patients with symptomatic SEM of renal cell carcinoma. Predictive factors for survival. Next to established predictive factors for survival, we analyzed the predictive value of the Motzer criteria in these patients. The Motzer criteria comprise a specific and validated risk model for survival in patients with renal cell carcinoma. After multivariable analysis, only Motzer intermediate (hazard ratio [HR] 17.4, 95% confidence interval [CI] 1.82-166, p=.01) and high risk (HR 39.3, 95% CI 3.10-499, p=.005) turned out to be significantly associated with survival in patients with renal cell carcinoma that we have operated on. In this study, we have demonstrated that decision making could have been optimized by implementing the Motzer criteria next to established prediction models. We, therefore, suggest that in future, in patients with SEM from renal cell carcinoma, the Motzer criteria are also taken into account. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Soft tissue digestion of Paradiplozoon vaalense for SEM of sclerites and simultaneous molecular analysis.

    Science.gov (United States)

    Dos Santos, Q M; Avenant-Oldewage, A

    2015-02-01

    Classification of most monogeneans is primarily based on size, shape, and arrangement of haptoral sclerites. These structures are often obscured or misinterpreted when studied using light microscopy, leading to confusion regarding defining characters. Scanning electron microscopy (SEM) has predominantly been used to study haptoral sclerites in smaller monogeneans, focusing on hooks and anchors. In the Diplozoidae, SEM has not been used to study haptoral sclerites. Using new and modified techniques, the sclerites of diplozoids collected in South Africa were successfully studied using SEM. The digestion buffer from a DNA extraction kit was used to digest the surrounding tissue, and Poly-L-lysine-coated and concavity slides were employed to limit the movement and loss of sclerites, with the latter being more user-friendly. In addition to the success of visualizing the sclerites using SEM, the digested tissue from as little as half of the haptor provided viable genetic material for molecular characterization. From the results presented here, the study of the sclerites of larger monogeneans using SEM, including those bearing clamps, is a viable possibility for future research. Also, this method may be beneficial for the study of other, non-haptoral sclerites, such as cirri in other families of monogeneans. During this study, Labeo capensis was noted as a valid host of Paradiplozoon vaalense in a region of the Vaal River where the type host, Labeo umbratus, appears to be absent.

  10. Minimal resin embedding of multicellular specimens for targeted FIB-SEM imaging.

    Science.gov (United States)

    Schieber, Nicole L; Machado, Pedro; Markert, Sebastian M; Stigloher, Christian; Schwab, Yannick; Steyer, Anna M

    2017-01-01

    Correlative light and electron microscopy (CLEM) is a powerful tool to perform ultrastructural analysis of targeted tissues or cells. The large field of view of the light microscope (LM) enables quick and efficient surveys of the whole specimen. It is also compatible with live imaging, giving access to functional assays. CLEM protocols take advantage of the features to efficiently retrace the position of targeted sites when switching from one modality to the other. They more often rely on anatomical cues that are visible both by light and electron microscopy. We present here a simple workflow where multicellular specimens are embedded in minimal amounts of resin, exposing their surface topology that can be imaged by scanning electron microscopy (SEM). LM and SEM both benefit from a large field of view that can cover whole model organisms. As a result, targeting specific anatomic locations by focused ion beam-SEM (FIB-SEM) tomography becomes straightforward. We illustrate this application on three different model organisms, used in our laboratory: the zebrafish embryo Danio rerio, the marine worm Platynereis dumerilii, and the dauer larva of the nematode Caenorhabditis elegans. Here we focus on the experimental steps to reduce the amount of resin covering the samples and to image the specimens inside an FIB-SEM. We expect this approach to have widespread applications for volume electron microscopy on multiple model organisms. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Refinement of Monte Carlo simulations of electron-specimen interaction in low-voltage SEM

    International Nuclear Information System (INIS)

    Kieft, Erik; Bosch, Eric

    2008-01-01

    A Monte Carlo tool is presented for the simulation of secondary electron (SE) emission in a scanning electron microscope (SEM). The tool is based on the Geant4 platform of CERN. The modularity of this platform makes it comparatively easy to add and test individual physical models. Our aim has been to develop a flexible and generally applicable tool, while at the same time including a good description of low-energy (<50 eV) interactions of electrons with matter. To this end we have combined Mott cross-sections with phonon-scattering based cross-sections for the elastic scattering of electrons, and we have adopted a dielectric function theory approach for inelastic scattering and generation of SEs. A detailed model of the electromagnetic fields from an actual SEM column has been included in the tool for ray tracing of secondary and backscattered electrons. Our models have been validated against experimental results through comparison of the simulation results with experimental yields, SE spectra and SEM images. It is demonstrated that the resulting simulation package is capable of quantitatively predicting experimental SEM images and is an important tool in building a deeper understanding of SEM imaging.

  12. A novel approach to TEM preparation with a (7-axis stage) triple-beam FIB-SEM system

    Science.gov (United States)

    Clarke, Jamil J.

    2015-10-01

    Preparation of lamellae from bulk to grid for Cs-corrected Transmission Electron Microscope (TEM) observation has mostly become routine work on the latest FIB-SEM systems, with standardized techniques that often are left to automation for the initial steps. The finalization of lamellae however, has mostly become, non-routine, non-repeatable and often driven by user experience level in most cases to produce high quality damage-less cross section. Materials processing of the latest technologies, with ever-shrinking Nano-sized structures pose challenges to modern FIB-SEM systems. This can often lead to specialized techniques and hyper-specific functions for producing ultra-thin high quality lamellae that often are lab specific, preventing practical use of such techniques across multiple materials and applications. Several factors that should be incorporated in processing fine structured materials successfully include how the use of electron and ion scan conditions can affect a thin section during ion milling, the type of ion species applied for material processing during the finalization of lamellae with gallium ions or of a smaller ion species type such as Ar/Xe, sample orientation of the lamella during the thinning process which is linked to ion beam incident angle as a direct relationship in the creation of waterfall effects or curtain effects, and how software can be employed to aid in the reduction of these artifacts with reproducible results regardless of FIB-SEM experience for site-specific lift outs. A traditional TEM preparation was performed of a fine structure specimen in pursuit of a process technique to produce a high quality TEM lamella which would address all of the factors mentioned. These new capabilities have been refined and improved upon during the FIB-SEM design and development stages with an end result of a new approach that yields an improvement in quality by the reduction of common ion milling artifacts such as curtain effects, amorphous

  13. An SEM/EDX study of bed agglomerates formed during fluidized bed combustion of three biomass fuels

    International Nuclear Information System (INIS)

    Scala, Fabrizio; Chirone, Riccardo

    2008-01-01

    The agglomeration behaviour of three biomass fuels (exhausted and virgin olive husk and pine seed shells) during fluidized bed combustion in a lab-scale reactor was studied by means of SEM/EDX analysis of bed agglomerate samples. The effect of the fuel ash composition, bed temperature and sand particle size on agglomeration was investigated. The study was focused on the main fuel ash components and on their interaction with the bed sand particles. Agglomeration was favoured by high temperature, small sand size, a high fraction of K and Na and a low fraction of Ca and Mg in the fuel ash. An initial fuel ash composition close to the low-melting point eutectic composition appears to enhance agglomeration. The agglomerates examined by SEM showed a hollow structure, with an internal region enriched in K and Na where extensive melting is evident and an external one where sand particles are only attached by a limited number of fused necks. Non-molten or partially molten ash structures deposited on the sand surface and enriched in Ca and Mg were also observed. These results support an ash deposition-melting mechanism: the ash released by burning char particles inside the agglomerates is quantitatively deposited on the sand surface and then gradually embedded in the melt. The low-melting point compounds in the ash migrate towards the sand surface enriching the outermost layer, while the ash structure is progressively depleted of these compounds

  14. Comparative evaluation of surface changes in four Ni-Ti instruments with successive uses - An SEM study.

    Science.gov (United States)

    Subha, N; Sikri, Vimal K

    2011-07-01

    To evaluate the surface alterations seen in four kinds of Nickel-Titanium (Ni-Ti) instruments using a scanning electron microscope (SEM) for five successive uses in preparing root canals of extracted human molars and also to determine whether the design of the instrument influenced the appearance of defects on the instrument surface. Four different types of instruments namely; ProFile, ProTaper Rotary, ProTaper Hand and K3 Endo were used in 300 mesio-buccal canals. The instruments were examined under the SEM, after every use, to assess the progress of changes on their surfaces for a maximum of five uses. Chi-square test. The most prevalent defects observed were pitting, followed by metal strips. Signs of discontinuity, microfractures and disruption of cutting edge were also evident. Number of defects increased with successive uses. ProTaper Hand showed significantly more microfractures and metal strips than other instruments from third use onwards. ProTaper Rotary and K3 Endo also showed significant changes.

  15. Distinction between amorphous and healed planar deformation features in shocked quartz using composite color scanning electron microscope cathodoluminescence (SEM-CL) imaging

    Science.gov (United States)

    Hamers, Maartje F.; Pennock, Gill M.; Herwegh, Marco; Drury, Martyn R.

    2016-10-01

    Planar deformation features (PDFs) in quartz are one of the most reliable and most widely used forms of evidence for hypervelocity impact. PDFs can be identified in scanning electron microscope cathodoluminescence (SEM-CL) images, but not all PDFs show the same CL behavior: there are nonluminescent and red luminescent PDFs. This study aims to explain the origin of the different CL emissions in PDFs. Focused ion beam (FIB) thin foils were prepared of specific sample locations selected in composite color SEM-CL images and were analyzed in a transmission electron microscope (TEM). The FIB preparation technique allowed a direct, often one-to-one correlation between the CL images and the defect structure observed in TEM. This correlation shows that composite color SEM-CL imaging allows distinction between amorphous PDFs on one hand and healed PDFs and basal Brazil twins on the other: nonluminescent PDFs are amorphous, while healed PDFs and basal Brazil twins are red luminescent, with a dominant emission peak at 650 nm. We suggest that the red luminescence is the result of preferential beam damage along dislocations, fluid inclusions, and twin boundaries. Furthermore, a high-pressure phase (possibly stishovite) in PDFs can be detected in color SEM-CL images by its blue luminescence.

  16. Speciation of uranium in minerals by Sem, Tem, μ-PIXE, XPS and XAFS

    International Nuclear Information System (INIS)

    Toshihiko Ohnuki; Hiroshi Isobe; Tomihiro Kamiya; Takuro Sakai; Takashi Murakami

    2001-01-01

    Many kinds of electromagnetic waves and particle beams are used as analytical probes for the investigation of uranium-mineralogy and speciation. The representatives of the probes are SEM, TEM, μ-PIRE, XPS and XAFS. Each of these analytical probes has its own advantages and disadvantages. We have performed studies to compare the advantages and disadvantages on the basis of the analysis of the distribution and speciation of U containing rock samples collected at the Koongarra uranium deposit, Australia. The spatial resolutions of the probes are in the order of TEM>SEM, μ-PIXE>XFAS, XPS. The lower detection limits of the probes are in the order of μ-PIXE< TEM, SEM< XFAS, XPS. Oxidation state of U was determined by XFAS and XPS. These results indicate that combination of the above probes can give us sufficient data on U speciation not only in natural rock samples but in solid samples obtained in the laboratory. (authors)

  17. Carotene location in processed food samples measured by cryo In-SEM Raman.

    Science.gov (United States)

    Lopez-Sanchez, Patricia; Schumm, Stephan; Pudney, Paul D A; Hazekamp, Johan

    2011-09-21

    Cryo In-SEM Raman has been used for the first time to localise carotene compounds in a food matrix. Raman spectra of lycopene and β-carotene have been obtained from sampling oil droplets and plant cell structures visualised with cryo-SEM in tomato and carrot based emulsions containing 5% oil. It was possible to identify the carotenoids in both the oil droplets and the cell walls. Furthermore our results gave some indication that the carotenoids were in the non-crystalline state. It has been suggested that a higher amount of carotenes solubilised into the oil phase of the food matrix would lead to a higher bioaccessibility, thus understanding the effect of processing conditions on micronutrients distribution in a food matrix might help the design of plant based food products with a better nutritional quality. This shows improved structural characterisation of the cryo-SEM with the molecular sensitivity of Raman spectroscopy as a promising approach for complex biological problems.

  18. The advancement of the built environment research through employment of structural equation modeling (SEM)

    Science.gov (United States)

    Wasilah, S.; Fahmyddin, T.

    2018-03-01

    The employment of structural equation modeling (SEM) in research has taken an increasing attention in among researchers in built environment. There is a gap to understand the attributes, application, and importance of this approach in data analysis in built environment study. This paper intends to provide fundamental comprehension of SEM method in data analysis, unveiling attributes, employment and significance and bestow cases to assess associations amongst variables and constructs. The study uses some main literature to grasp the essence of SEM regarding with built environment research. The better acknowledgment of this analytical tool may assist the researcher in the built environment to analyze data under complex research questions and to test multivariate models in a single study.

  19. High resolution SEM characterization of nano-precipitates in ODS steels.

    Science.gov (United States)

    Jóźwik, Iwona; Strojny-Nędza, Agata; Chmielewski, Marcin; Pietrzak, Katarzyna; Kurpaska, Łukasz; Nosewicz, Szymon

    2018-05-01

    The performance of the present-day scanning electron microscopy (SEM) extends far beyond delivering electronic images of the surface topography. Oxide dispersion strengthened (ODS) steel is on of the most promising materials for the future nuclear fusion reactor because of its good radiation resistance, and higher operation temperature up to 750°C. The microstructure of ODS should not exceed tens of nm, therefore there is a strong need in a fast and reliable technique for their characterization. In this work, the results of low-kV SEM characterization of nanoprecipitates formed in the ODS matrix are presented. Application of highly sensitive photo-diode BSE detector in SEM imaging allowed for the registration of single nm-sized precipitates in the vicinity of the ODS alloys. The composition of the precipitates has been confirmed by TEM-EDS. © 2018 Wiley Periodicals, Inc.

  20. Enhanced EDX images by fusion of multimodal SEM images using pansharpening techniques.

    Science.gov (United States)

    Franchi, G; Angulo, J; Moreaud, M; Sorbier, L

    2018-01-01

    The goal of this paper is to explore the potential interest of image fusion in the context of multimodal scanning electron microscope (SEM) imaging. In particular, we aim at merging the backscattered electron images that usually have a high spatial resolution but do not provide enough discriminative information to physically classify the nature of the sample, with energy-dispersive X-ray spectroscopy (EDX) images that have discriminative information but a lower spatial resolution. The produced images are named enhanced EDX. To achieve this goal, we have compared the results obtained with classical pansharpening techniques for image fusion with an original approach tailored for multimodal SEM fusion of information. Quantitative assessment is obtained by means of two SEM images and a simulated dataset produced by a software based on PENELOPE. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  1. Development of an Economical Interfacing Circuit for Upgrading of SEM Data Printing System

    International Nuclear Information System (INIS)

    Punnachaiya, S.; Thong-Aram, D.

    2002-01-01

    The operating conditions of a Scanning Electron Microscope (SEM) i.e., magnification, accelerating voltage, micron mark and film identification labeling, are very important for the accurate interpretation of a micrograph picture. In the old model SEM, the built-in data printing system for film identification can be inputted only the numerical number. This will be made a confusing problems when various operating conditions were applied in routine work. An economical interfacing circuit, therefore, was developed to upgrade the data printing system for capable of alphanumerical labeling. The developed circuit was tested on both data printing systems of JSM-T220 and JSM-T330 (JEOL SEM). It was found that the interfacing function worked properly and easily installed

  2. Precise and economic FIB/SEM for CLEM: with 2 nm voxels through mitosis.

    Science.gov (United States)

    Luckner, Manja; Wanner, Gerhard

    2018-05-23

    A portfolio is presented documenting economic, high-resolution correlative focused ion beam scanning electron microscopy (FIB/SEM) in routine, comprising: (i) the use of custom-labeled slides and coverslips, (ii) embedding of cells in thin, or ultra-thin resin layers for correlative light and electron microscopy (CLEM) and (iii) the claim to reach the highest resolution possible with FIB/SEM in xyz. Regions of interest (ROIs) defined in light microscope (LM), can be relocated quickly and precisely in SEM. As proof of principle, HeLa cells were investigated in 3D context at all stages of the cell cycle, documenting ultrastructural changes during mitosis: nuclear envelope breakdown and reassembly, Golgi degradation and reconstitution and the formation of the midzone and midbody.

  3. Encontros e desvios nos semáforos: investigando artistas em Florianópolis/SC

    Directory of Open Access Journals (Sweden)

    Beatriz S. Albino

    2013-03-01

    Full Text Available http://dx.doi.org/10.5007/2178-4582.2012v46n2p469 A ideia de investigar artistas que atuam em semáforos de Florianópolis/SC teve sua origem em um estranhamento que nos fez vê-los na forma de uma alteridade radical. A pesquisa etnográfica permitiu descobrir relações simbólicas de pertencimentoe de desvio entre os artistas, destacando-se a figura de um “outro”, próximo, mas perigoso, que partilha simbolicamente os semáforos: o micróbio, estrangeiro que faria confundir o artista com a marginalidade. No semáforo ocorre também, no entanto, a reafirmação, por meio das performances dos artistas, do que deles é esperado: a comicidade, o virtuosismo, a aparência adequada.

  4. Neuropsicología de la demencia semántica

    OpenAIRE

    Andrade Quintero, Luz Helena

    2012-01-01

    La Demencia Semántica causa alteraciones en la capacidad para recordar el significado de las palabras, rostros y objetos, producto de atrofia asimétrica o bilateral de los lóbulos temporales anteriores. Clínicamente se han observado múltiples síndromes clínicos superpuestos con otras enfermedades degenerativas como la Afasia Primaria Progresiva y la Demencia tipo Alzheimer. El propósito de este estudio fue identificar alteraciones lingüísticas y semánticas en un grupo de pacientes con Demenci...

  5. SEM-EDX IDENTIFICATION OF PARTICLES FROM FOG IN AN INDUSTRIALLY POLLUTED REGION OF CZECH REPUBLIC

    Czech Academy of Sciences Publication Activity Database

    Stoyanova, V.; Shoumkova, A.; Fišák, Jaroslav; Tsacheva, Ts.

    Vol. II - BUA32, č. 1 (2010), s. 269-276 ISSN 1314-2704. [International Multidisciplinary Scientific GeoConference SGEM 2010 /10./. Albena, 20.06.2010-26.06.2010] Institutional research plan: CEZ:AV0Z30420517 Keywords : SEM-EDX * solid atmospheric pollutants * trace elements * heavy metals * Czech Republic Subject RIV: DG - Athmosphere Sciences, Meteorology http://www.ipc.bas.bg/PPages/Shoumkova/Publications/Articles/2010%20SEM-EDX%20identification%20of%20FP.pdf

  6. El adjetivo en el Nuevo Testamento: clasificación semántica

    OpenAIRE

    Romero González, Dámaris

    2011-01-01

    El adjetivo ha sido estudiado habitualmente desde el punto de vista del sustantivo, como una subclase de éste, ya que ambos poseen una morfología similar. Semánticamente, la mayoría de las gramáticas los clasifican según su capacidad para calificar o determinar al sustantivo, denominándolo calificativo y determinativo respectivamente. Dentro de esta clasificación, se han establecido subgrupos basados en criterios semánticos. Por tanto, el propósito de esta tesis es esbozar una nueva...

  7. Wi-Fi Salvador: mapeamento colaborativo e redes sem fio no Brasil

    OpenAIRE

    Lemos, André; Pastor, Leonardo; Oliveira, Nelson

    2012-01-01

    O trabalho faz uma breve demonstração de políticas públicas para inclusão digital por meio da disponibilização do acesso à internet por meio de redes sem fio e discute a forma como as pessoas se relacionam com os lugares, de acordo com a existência ou inexistência de acessibilidade à internet. O objetivo é discutir o acesso à internet pelas redes sem fio no Brasil e, mais especificamente, na cidade de Salvador. Este trabalho é fruto de pesquisa realizada no âmbito do Grupo de Pesquisa em Cibe...

  8. Mapping the Complex Morphology of Cell Interactions with Nanowire Substrates Using FIB-SEM

    DEFF Research Database (Denmark)

    Wierzbicki, Rafal; Købler, Carsten; Jensen, Mikkel Ravn Boye

    2013-01-01

    Using high resolution focused ion beam scanning electron microscopy (FIB-SEM) we study the details of cell-nanostructure interactions using serial block face imaging. 3T3 Fibroblast cellular monolayers are cultured on flat glass as a control surface and on two types of nanostructured scaffold...... substrates made from silicon black (Nanograss) with low- and high nanowire density. After culturing for 72 hours the cells were fixed, heavy metal stained, embedded in resin, and processed with FIB-SEM block face imaging without removing the substrate. The sample preparation procedure, image acquisition...

  9. STEM mode in the SEM for the analysis of cellular sections prepared by ultramicrotome sectioning

    International Nuclear Information System (INIS)

    Hondow, N; Harrington, J; Brydson, R; Brown, A

    2012-01-01

    The use of the dual imaging capabilities of a scanning electron microscope fitted with a transmitted electron detector is highlighted in the analysis of samples with importance in the field of nanotoxicology. Cellular uptake of nanomaterials is often examined by transmission electron microscopy of thin sections prepared by ultramicrotome sectioning. Examination by SEM allows for the detection of artefacts caused by sample preparation (eg. nanomaterial pull-out) and the complementary STEM mode permits study of the interaction between nanomaterials and cells. Thin sections of two nanomaterials of importance in nanotoxicology (cadmium selenide quantum dots and single walled carbon nanotubes) are examined using STEM mode in the SEM.

  10. Marginal adaptation of a low-shrinkage silorane-based composite: A SEM-analysis

    DEFF Research Database (Denmark)

    Schmidt, Malene; Bindslev, Preben Hørsted; Poulsen, Sven

    2012-01-01

    shrinkage, has been marketed. Objective. To investigate whether reduced polymerization shrinkage improves the marginal adaptation of composite restorations. Material and methods. A total of 156 scanning electron microscopy (SEM) pictures (78 baseline, 78 follow-up) of the occlusal part of Class II......-casts of the restorations were used for SEM pictures at x 16 magnification. Pictures from baseline and follow-up (398 days, SD 29 days) were randomized and the examiner was blinded to the material and the age of the restoration. Stereologic measurements were used to calculate the length and the width of the marginal...

  11. SEM characterization of anatomical variation in chitin organization in insect and arthropod cuticles.

    Science.gov (United States)

    Chandran, Rakkiyappan; Williams, Lee; Hung, Albert; Nowlin, Kyle; LaJeunesse, Dennis

    2016-03-01

    The cuticles of insects and arthropods have some of the most diverse material properties observed in nature, so much so that it is difficult to imagine that all cutciles are primarily composed of the same two materials: a fibrous chitin network and a matrix composed of cuticle proteins. Various factors contribute to the mechanical and optical properties of an insect or arthropod cuticle including the thickness and composition. In this paper, we also identified another factor that may contribute to the optical, surface, and mechanical properties of a cuticle, i.e. the organization of chitin nanofibers and chitin fiber bundles. Self-assembled chitin nanofibers serve as the foundation for all higher order chitin structures in the cuticles of insects and other arthropods via interactions with structural cuticle proteins. Using a technique that enables the characterization of chitin organization in the cuticle of intact insects and arthropod exoskeletons, we demonstrate a structure/function correlation of chitin organization with larger scale anatomical structures. The chitin scaffolds in cuticles display an extraordinarily diverse set of morphologies that may reflect specific mechanical or physical properties. After removal of the proteinaceous and mineral matrix of a cuticle, we observe using SEM diverse nanoscale and micro scale organization of in-situ chitin in the wing, head, eye, leg, and dorsal and ventral thoracic regions of the periodical cicada Magicicada septendecim and in other insects and arthropods. The organization of chitin also appears to have a significant role in the organization of nanoscale surface structures. While microscale bristles and hairs have long been known to be chitin based materials formed as cellular extensions, we have found a nanostructured layer of chitin in the cuticle of the wing of the dog day annual cicada Tibicen tibicens, which may be the scaffold for the nanocone arrays found on the wing. We also use this process to examine

  12. Revealed preference with limited consideration

    NARCIS (Netherlands)

    Demuynck, T.; Seel, C.

    2014-01-01

    We derive revealed preference tests for models where individuals use consideration sets to simplify their consumption problem. Our basic test provides necessary and sufficient conditions for consistency of observed choices with the existence of consideration set restrictions. The same conditions can

  13. SEM and microCT validation for en face OCT imagistic evaluation of endodontically treated human teeth

    Science.gov (United States)

    Negrutiu, Meda L.; Nica, Luminita; Sinescu, Cosmin; Topala, Florin; Ionita, Ciprian; Bradu, Adrian; Petrescu, Emanuela L.; Pop, Daniela M.; Rominu, Mihai; Podoleanu, Adrian Gh.

    2011-03-01

    Successful root canal treatment is based on diagnosis, treatment planning, knowledge of tooth anatomy, endodontic access cavity design, controlling the infection by thorough cleaning and shaping, methods and materials used in root canal obturation. An endodontic obturation must be a complete, three-dimensional filling of the root canal system, as close as possible to cemento-dentinal junction, without massive overfilling or underfilling. There are several known methods which are used to assess the quality of the endodontic sealing, but most are invasive. These lead to the destruction of the samples and often no conclusion could be drawn in respect to the existence of any microleakage in the investigated areas of interest. Using an time domain en-face OCT system, we have recently demonstrated real time thorough evaluation of quality of root canal fillings. The purpose of this in vitro study was to validate the en face OCT imagistic evaluation of endodontically treated human teeth by using scanning electron microscopy (SEM) and microcomputer tomography (μCT). SEM investigations evidenced the nonlinear aspect of the interface between the endodontic filling material and the root canal walls and materials defects in some samples. The results obtained by μCT revealed also some defects inside the root-canal filling and at the interfaces between the material and the root canal walls. The advantages of the OCT method consist in non-invasiveness and high resolution. In addition, en face OCT investigations permit visualization of the more complex stratified structure at the interface between the filling material and the dental hard tissue.

  14. SEM, TEM, and IHC Analysis of the Sinus Node and Its Implications for the Cardiac Conduction System

    Directory of Open Access Journals (Sweden)

    D. Mandrioli

    2013-01-01

    Full Text Available More than 100 years after the discovery of the sinus node (SN by Keith and Flack, the function and structure of the SN have not been completely established yet. The anatomic architecture of the SN has often been described as devoid of an organized structure; the origin of the sinus impulse is still a matter of debate, and a definite description of the long postulated internodal specialized tract conducting the impulse from the SN to the atrioventricular node (AVN is still missing. In our previously published study, we proposed a morphologically ordered structure for the SN. As a confirmation of what was presented then, we have added the results of additional observations regarding the structural particularities of the SN. We investigated the morphology of the sinus node in the human hearts of healthy individuals using histochemical, immunohistochemical, optical, and electron microscopy (SEM, TEM. Our results confirmed that the SN presents a previously unseen highly organized architecture.

  15. 3D SEM for surface topography quantification – a case study on dental surfaces

    International Nuclear Information System (INIS)

    Glon, F; Flys, O; Lööf, P-J; Rosén, B-G

    2014-01-01

    3D analysis of surface topography is becoming a more used tool for industry and research. New ISO standards are being launched to assist in quantifying engineering surfaces. The traditional optical measuring instrumentation used for 3D surface characterization has been optical interferometers and confocal based instrumentation. However, the resolution here is limited in the lateral dimension to the wavelength of visible light to about 500 nm. The great advantage using the SEM for topography measurements is the high flexibility to zoom from low magnifications and locating interesting areas to high magnification of down to nanometer large surface features within seconds. This paper presents surface characterization of dental implant micro topography. 3D topography data was created from SEM images using commercial photogrammetric software. A coherence scanning interferometer was used for reference measurements to compare with the 3D SEM measurements on relocated areas. As a result of this study, measurements emphasizes that the correlation between the accepted CSI measurements and the new technology represented by photogrammetry based on SEM images for many areal characterization parameters are around or less than 20%. The importance of selecting sampling and parameter sensitivity to varying sampling is high-lighted. Future work includes a broader study of limitations of the photogrammetry technique on certified micro-geometries and more application surfaces at different scales

  16. 3D reconstruction of SEM images by use of optical photogrammetry software.

    Science.gov (United States)

    Eulitz, Mona; Reiss, Gebhard

    2015-08-01

    Reconstruction of the three-dimensional (3D) surface of an object to be examined is widely used for structure analysis in science and many biological questions require information about their true 3D structure. For Scanning Electron Microscopy (SEM) there has been no efficient non-destructive solution for reconstruction of the surface morphology to date. The well-known method of recording stereo pair images generates a 3D stereoscope reconstruction of a section, but not of the complete sample surface. We present a simple and non-destructive method of 3D surface reconstruction from SEM samples based on the principles of optical close range photogrammetry. In optical close range photogrammetry a series of overlapping photos is used to generate a 3D model of the surface of an object. We adapted this method to the special SEM requirements. Instead of moving a detector around the object, the object itself was rotated. A series of overlapping photos was stitched and converted into a 3D model using the software commonly used for optical photogrammetry. A rabbit kidney glomerulus was used to demonstrate the workflow of this adaption. The reconstruction produced a realistic and high-resolution 3D mesh model of the glomerular surface. The study showed that SEM micrographs are suitable for 3D reconstruction by optical photogrammetry. This new approach is a simple and useful method of 3D surface reconstruction and suitable for various applications in research and teaching. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Hacia una visión generativista de la semántica lexical

    Directory of Open Access Journals (Sweden)

    Morales A. Bernardo

    1992-06-01

    Full Text Available

    Uno de los objetivos de la teoría semántica de una lengua natural es dar información satisfactoria sobre el significado de las formas lingüísticas. Consideramos que de éstas, las de mayor  importancia significativa son la palabra, la oración y el texto. La palabra, porque en virtud de su compleja estructura semántica y psicológica funciona como el principal medio para la abstracción y conformación de los conceptos destinados para la comunicación; la oración, porque es la unidad de la lengua viva que expresa relaciones de conceptos; el texto, porque es la explicitación del pensamiento en la interacción humana. Las semánticas lexical, oracional y textual son los tres grandes capítulos de la semántica lingüística.


  18. Surface topography characterization using 3D stereoscopic reconstruction of SEM images

    Science.gov (United States)

    Vedantha Krishna, Amogh; Flys, Olena; Reddy, Vijeth V.; Rosén, B. G.

    2018-06-01

    A major drawback of the optical microscope is its limitation to resolve finer details. Many microscopes have been developed to overcome the limitations set by the diffraction of visible light. The scanning electron microscope (SEM) is one such alternative: it uses electrons for imaging, which have much smaller wavelength than photons. As a result high magnification with superior image resolution can be achieved. However, SEM generates 2D images which provide limited data for surface measurements and analysis. Often many research areas require the knowledge of 3D structures as they contribute to a comprehensive understanding of microstructure by allowing effective measurements and qualitative visualization of the samples under study. For this reason, stereo photogrammetry technique is employed to convert SEM images into 3D measurable data. This paper aims to utilize a stereoscopic reconstruction technique as a reliable method for characterization of surface topography. Reconstructed results from SEM images are compared with coherence scanning interferometer (CSI) results obtained by measuring a roughness reference standard sample. This paper presents a method to select the most robust/consistent surface texture parameters that are insensitive to the uncertainties involved in the reconstruction technique itself. Results from the two-stereoscopic reconstruction algorithms are also documented in this paper.

  19. Characterisation of early medieval frescoes by {mu}-PIXE, SEM and Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, A. E-mail: zucc@ge.infn.it; Prati, P.; Bouquillon, A.; Giuntini, L.; Massi, M.; Migliori, A.; Cagnana, A.; Roascio, S

    2004-06-01

    We have studied the VIII-IX century frescoes of the Longobard temple of Cividale del Friuli in Italy with noninvasive sampling and, for the first time in such a context, with high chemical and spatial sensitivity techniques (PIXE, SEM and Raman). Results demonstrate richness of manufacturing details and integrate in a substantial way the historic and artistic framework of this early medieval monument.

  20. 78 FR 50079 - Information Collection Activities: Safety and Environmental Management Systems (SEMS); Proposed...

    Science.gov (United States)

    2013-08-16

    ... DEPARTMENT OF THE INTERIOR Bureau of Safety and Environmental Enforcement [Docket ID BSEE-2013-0005; OMB Control Number 1014-0017: 134E1700D2 EEEE500000 ET1SF0000.DAQ000] Information Collection Activities: Safety and Environmental Management Systems (SEMS); Proposed Collection; Comment Request...

  1. MORPHOLOGICAL ASPECTS OF HUMAN LENS CAPSULES - A COMPARATIVE LM, SEM AND TEM EXAMINATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; LOS, LI; VANDERVEEN, G; WORST, JGF

    1991-01-01

    Lens capsules of patients of advanced age, obtained after extracapsular cataract surgery, were carefully prepared for a combined LM, TEM and SEM investigation, after preliminary washing and mounting onto a holder in a buffer solution. After pre-fixation with GA, samples were postfixed for LM/TEM and

  2. Integration of Correlative Raman microscopy in a dual beam FIB-SEM J. of Raman Spectroscopy

    NARCIS (Netherlands)

    Timmermans, Frank Jan; Liszka, B.; Lenferink, Aufrid T.M.; van Wolferen, Hendricus A.G.M.; Otto, Cornelis

    2016-01-01

    We present an integrated confocal Raman microscope in a focused ion beam scanning electron microscope (FIB SEM). The integrated system enables correlative Raman and electron microscopic analysis combined with focused ion beam sample modification on the same sample location. This provides new

  3. Characterisation of early medieval frescoes by μ-PIXE, SEM and Raman spectroscopy

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Prati, P.; Bouquillon, A.; Giuntini, L.; Massi, M.; Migliori, A.; Cagnana, A.; Roascio, S.

    2004-01-01

    We have studied the VIII-IX century frescoes of the Longobard temple of Cividale del Friuli in Italy with noninvasive sampling and, for the first time in such a context, with high chemical and spatial sensitivity techniques (PIXE, SEM and Raman). Results demonstrate richness of manufacturing details and integrate in a substantial way the historic and artistic framework of this early medieval monument

  4. The Great War and Remembrance in Jose Leon Machado's "Memoria das Estrelas sem Brilho"

    Science.gov (United States)

    Azevedo, Milton M.

    2011-01-01

    This article analyzes Jose Leon Machado's novel, "Memoria das Estrelas sem Brilho," as a multilayered historical novel in which a war story provides a background for comments on aspects of early twentieth-century Portuguese society, such as male bonding, religion, sexual mores, and social stratification. (Contains 11 notes.)

  5. Combination of FTIR and SEM for Identifying Freshwater-Cultured Pearls from Different Quality

    Science.gov (United States)

    Satitkune, Somruedee; Monarumit, Natthapong; Boonmee, Chakkrich; Phlayrahan, Aumaparn; Promdee, Kittiphop; Won-in, Krit

    2016-03-01

    The freshwater-cultured pearl ( Chamberlainia hainesiana species) is an organic gemstone mainly composed of calcium carbonate mineral including calcite, aragonite and vaterite phases. Generally, the quality of freshwater-cultured pearl is based on its luster. The high luster pearl is full of the aragonite phase without vaterite phase. On the other hand, the low luster pearl consists of aragonite and vaterite phases. These data could be proved by the Fourier Transform Infrared (FTIR) spectroscopy combined with the scanning electron microscopy (SEM). As the results, the high luster pearl similarly shows the FTIR spectrum of aragonite phase, and also, it shows the hexagonal shape of aragonite for the SEM image. On the other hand, the FTIR spectrum of low luster pearl has been pointed to the mixture component among aragonite and vaterite phases, and based on the SEM image; the irregular form is also interpreted to the mixture of aragonite and vaterite phases. This research concludes that the quality of freshwater-cultured pearls can be identified by the combination data of FTIR spectra and SEM images. These techniques are suitable for applied gemology.

  6. MICROORGANISMS FOUND IN SECONDARY CATARACT MATERIAL OF ECCE PATIENTS, A STUDY WITH SEM AND TEM

    NARCIS (Netherlands)

    KALICHARAN, D; JONGEBLOED, WL; LOS, LI; WORST, JGF

    1993-01-01

    Globular secondary cataract material, removed from 24 patients with ECCE after ophthalmic cleaning of the anterior capsule, were investigated with SEM and TEM. Besides spherical, somewhat oval shaped bodies of various shape and size comparable with those found in cataractous lenses, (an)aerobic

  7. (AN)AEROBIC BACTERIA FOUND IN SECONDARY-CATARACT MATERIAL - A SEM/TEM STUDY

    NARCIS (Netherlands)

    KALICHARAN, D; JONGEBLOED, WL; LOS, LI; WORST, JGF

    1992-01-01

    Twentyfour patients, who had marked reduction of vision due to secondary-cataract developed after an ECCE, were treated by surgical cleaning of the posterior lens capsule. During this procedure globular secondary-cataract material was removed and collected for morphological examination by SEM and

  8. Controlled dehydration of a biological sample using an alternative form of environmental SEM

    Czech Academy of Sciences Publication Activity Database

    Neděla, Vilém

    2010-01-01

    Roč. 237, č. 1 (2010), s. 7-11 ISSN 0022-2720 Institutional research plan: CEZ:AV0Z20650511 Keywords : biological sample * dehydration * environmental SEM * AQUASEM II * hydration system Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.872, year: 2010

  9. Fractionation of Pb in Soil of Abandoned Pb Mine by SEM-EDX and ...

    African Journals Online (AJOL)

    Therefore, scanning electron microscopy coupled with energy dispersive X-ray spectrometer (SEM-EDX) were used for the identification of fractional forms of Pb that are liable to leach out/down from the soil matrix of the abandoned mine site to surface-andunderground water bodies of the nearby localities, and to determine ...

  10. A Comparative SEM-EDS Elemental Composition of Mud in Coastal ...

    African Journals Online (AJOL)

    The present study was aimed to understand the comparative abundance and source of elemental constituents in mud of four coastal shrimp farming areas, Vunh Tau (VT), Nha Trang (NT), Da Nang (DN) and Hue (HU) in Viet Nam using SEM-EDS analysis. Mud samples were collected from shrimp farming coastal zones ...

  11. Recent Advances on In Situ SEM Mechanical and Electrical Characterization of Low-Dimensional Nanomaterials

    Directory of Open Access Journals (Sweden)

    Chenchen Jiang

    2017-01-01

    Full Text Available In the past decades, in situ scanning electron microscopy (SEM has become a powerful technique for the experimental study of low-dimensional (1D/2D nanomaterials, since it can provide unprecedented details for individual nanostructures upon mechanical and electrical stimulus and thus uncover the fundamental deformation and failure mechanisms for their device applications. In this overview, we summarized recent developments on in situ SEM-based mechanical and electrical characterization techniques including tensile, compression, bending, and electrical property probing on individual nanostructures, as well as the state-of-the-art electromechanical coupling analysis. In addition, the advantages and disadvantages of in situ SEM tests were also discussed with some possible solutions to address the challenges. Furthermore, critical challenges were also discussed for the development and design of robust in situ SEM characterization platform with higher resolution and wider range of samples. These experimental efforts have offered in-depth understanding on the mechanical and electrical properties of low-dimensional nanomaterial components and given guidelines for their further structural and functional applications.

  12. A Sandwich-Type Standard Error Estimator of SEM Models with Multivariate Time Series

    Science.gov (United States)

    Zhang, Guangjian; Chow, Sy-Miin; Ong, Anthony D.

    2011-01-01

    Structural equation models are increasingly used as a modeling tool for multivariate time series data in the social and behavioral sciences. Standard error estimators of SEM models, originally developed for independent data, require modifications to accommodate the fact that time series data are inherently dependent. In this article, we extend a…

  13. Are the evidences of forensic entomology preserved in ethanol suitable for SEM studies?

    Science.gov (United States)

    López-Esclapez, Raquel; García, María-Dolores; Arnaldos, María-Isabel; Presa, Juan José; Ubero-Pascal, Nicolás

    2014-07-01

    In forensic practice, the use of arthropod evidences to estimate the postmortem interval is a very good approach when the elapsed time from death is long, but it requires the correct identification of the specimens. This is a crucial step, not always easy to achieve, in particular when dealing with immature specimens. In this case, scanning electronic microscopy (SEM) can be useful, but the techniques used to preserve specimens in forensic practice are usually different from those used to prepare specimens for SEM studies. To determine whether forensic evidences preserving techniques are also compatible with SEM analysis, we have compared specimens of all the immature stages of Calliphora vicina Robineau-Desvoidy, 1830 (Diptera, Calliphoridae) preserved in 70% ethanol, with others prepared with aldehydic fixative techniques that are more appropriate for SEM studies. At the same time, two drying techniques have also been compared with both fixative techniques, the critical point drying and air-drying following with hexamethyldisilizane treatment (HMDS). Our results indicate that there are not basis against recommending the use of ethanol to preserve forensic entomological evidences and that both drying methods appear to offer good results for second and third instar larvae, although HMDS behaves better with eggs and pupae. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Field emission scanning electron microscopy (FE-SEM) as an approach for nanoparticle detection inside cells

    Czech Academy of Sciences Publication Activity Database

    Havrdová, M.; Poláková, K.; Skopalík, J.; Vůjtek, M.; Mokdad, A.; Homolková, M.; Tuček, J.; Nebesářová, Jana; Zbořil, R.

    2014-01-01

    Roč. 67, DEC 2014 (2014), s. 149-154 ISSN 0968-4328 Institutional support: RVO:60077344 Keywords : Field emission scanning electronmicroscopy (FE-SEM) * Stem cells * Iron oxide nanoparticles * Cellular morphology * Endosomes * Cell uptake Subject RIV: FD - Oncology ; Hematology Impact factor: 1.988, year: 2014

  15. Surface ultrastructural (SEM) characteristics of oropharyngeal cavity of house sparrow (Passer domesticus).

    Science.gov (United States)

    Abumandour, Mohamed M A

    2018-06-01

    The focus of the present study is to provide a full morphological description of the oropharyngeal cavity of the house sparrow. The head of six birds was prepared for gross examination and by stereo and electron microscopy. The bifid lingual apex has multiple long, rostrally directed needle-like processes. The lateral border of the apex carries rostromedially directed needle-like processes. The dorsal lingual surface of the apex and body carries numerous caudomedially directed filiform papillae and many orifices of lingual salivary glands. The lingual body is divided into two parts: rostral and caudal. The caudal part is divided into two laterally elevated regions by a median groove, while the rostral part is bounded laterally by a rostrodorsally directed papillary row, which on SEM is formed from two rows. On SEM, the lingual root has many orifices of posterior salivary glands. The pharyngeal papillary row is located at the caudal border of the laryngeal mound, but this single papillary row is formed from two rows at SEM magnification. The laryngeal cleft continues caudally as a laryngeal fissure bounded by two longitudinal rows of caudally directed papillae; at high SEM magnification, this fissure is divided into two halves by a median ridge which carries caudally directed papillae on its posterior part. The choanal cleft proceeds rostrally by the median tubercle. There are a small number of orifices of palatine salivary glands. The morphological characters of the oropharyngeal cavity of the sparrow confirm its adaptation to surrounding environmental conditions and available food particles.

  16. Effects of Missing Data Methods in SEM under Conditions of Incomplete and Nonnormal Data

    Science.gov (United States)

    Li, Jian; Lomax, Richard G.

    2017-01-01

    Using Monte Carlo simulations, this research examined the performance of four missing data methods in SEM under different multivariate distributional conditions. The effects of four independent variables (sample size, missing proportion, distribution shape, and factor loading magnitude) were investigated on six outcome variables: convergence rate,…

  17. Study of Morphological Changes of The Lime Putties During Maturing by SEM/ESEM

    Czech Academy of Sciences Publication Activity Database

    Navrátilová, Eva; Neděla, Vilém

    2017-01-01

    Roč. 23, S1 (2017), s. 2186-2187 ISSN 1431-9276 R&D Projects: GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : SEM * ESEM * morphological changes * lime putties Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering OBOR OECD: Civil engineering Impact factor: 1.891, year: 2016

  18. Recent Advances on In Situ SEM Mechanical and Electrical Characterization of Low-Dimensional Nanomaterials.

    Science.gov (United States)

    Jiang, Chenchen; Lu, Haojian; Zhang, Hongti; Shen, Yajing; Lu, Yang

    2017-01-01

    In the past decades, in situ scanning electron microscopy (SEM) has become a powerful technique for the experimental study of low-dimensional (1D/2D) nanomaterials, since it can provide unprecedented details for individual nanostructures upon mechanical and electrical stimulus and thus uncover the fundamental deformation and failure mechanisms for their device applications. In this overview, we summarized recent developments on in situ SEM-based mechanical and electrical characterization techniques including tensile, compression, bending, and electrical property probing on individual nanostructures, as well as the state-of-the-art electromechanical coupling analysis. In addition, the advantages and disadvantages of in situ SEM tests were also discussed with some possible solutions to address the challenges. Furthermore, critical challenges were also discussed for the development and design of robust in situ SEM characterization platform with higher resolution and wider range of samples. These experimental efforts have offered in-depth understanding on the mechanical and electrical properties of low-dimensional nanomaterial components and given guidelines for their further structural and functional applications.

  19. Does your SEM really tell the truth?--How would you know? Part 1.

    Science.gov (United States)

    Postek, Michael T; Vladár, András E

    2013-01-01

    The scanning electron microscope (SEM) has gone through a tremendous evolution to become a critical tool for many and diverse scientific and industrial applications. The high resolution of the SEM is especially suited for both qualitative and quantitative applications especially for nanotechnology and nanomanufacturing. Quantitatively, measurement, or metrology is one of the main uses. It is likely that one of the first questions asked before even the first scanning electron micrograph was ever recorded was: "… how big is that?" The quality of that answer has improved a great deal over the past few years especially since today these instruments are being used as a primary measurement tool on semiconductor processing lines to monitor the manufacturing processes. The well-articulated needs of semiconductor production prompted a rapid evolution of the instrument and its capabilities. Over the past 20 years or so, instrument manufacturers, through substantial semiconductor industry investment of research and development (R&D) money, have vastly improved the performance of these instruments. All users have benefited from this investment, especially where quantitative measurements with an SEM are concerned. But, how good are these data? This article discusses some of the most important aspects and larger issues associated with imaging and measurements with the SEM that every user should know, and understand before any critical quantitative work is attempted. © Wiley Periodicals, Inc.

  20. On some contrast reversals in SEM: Application to metal/insulator systems

    International Nuclear Information System (INIS)

    Cazaux, Jacques

    2008-01-01

    Contrast changes of SEM images with experimental conditions (beam energy, angle of detection, etc.) are analyzed by combining physical arguments based on secondary electron emission (SEE) to instrumental arguments involving detection. Possible occurrences of contrast reversals are explored to illustrate these changes in a striking manner. Deduced from SEE yield data, simulated SEM images show a material contrast reversal for a Pt/quartz specimen, a result partly supported by real images of a Cr/quartz integrated circuit. A shift of reversal energy with the detector's position is deduced from a difference in secondary electrons (SE) angular distributions between metals and insulators. Similarly, changes of topographic contrast with detection conditions, specimen composition and angle of tilt are investigated and a possible contrast reversal is again indicated. Finally, it is shown how charging contrast deduced from the expected evolution of SEE yield during irradiation is amplified by in-lens detection: a point illustrated by a contrast reversal of images of SiC particles. The main application concerns a proper interpretation of SEM images that is essential in the investigation of devices obtained from lithographic processes. The discussion on material contrast outlines the difficulty in generalizing the present analysis based on published data and experimental strategies based on implementing specific attachments in the SEM or on biasing the specimen holder are suggested.