WorldWideScience

Sample records for self-validating thermocouple svt

  1. Thermocouple

    International Nuclear Information System (INIS)

    Charlesworth, F.D.W.

    1983-01-01

    A thermocouple is provided by a cable of coaxial form with inner and outer conductors of thermocouple forming materials and with the conductors electrically joined together at one end of the cable to form the thermocouple junction. The inner and outer conductors are preferably of chromel and stainless steel respectively. (author)

  2. STAR/SVT alignment within a finite magnetic field

    International Nuclear Information System (INIS)

    Barannikova, O.Yu.; Belaga, V.V.; Ososkov, G.A.; Panebrattsev, Yu.A.; Bellweid, R.K.; Pruneau, C.A.; Wilson, W.K.

    1999-01-01

    We report on the development of SVT (Silicon Vertex Tracker) software for the purpose of the SVT and TPC (Time Projection Chamber) relative alignment as well as the internal alignment of the SVT components. The alignment procedure described complements the internal SVT alignment procedure discussed in Star Note 356. It involves track reconstruction in both the Star TPC and SVT for the calibration of the SVT geometry in the presence of a finite magnetic field. This new software has been integrated under the package SAL already running under STAR. Both the implementation and the performance of the alignment algorithm are described. We find that the current software implementation in SAL should enable a very satisfactory internal SVT alignment as well as an excellent SVT to TPC relative alignment

  3. General-purpose heat source safety verification test series: SVT-11 through SVT-13

    International Nuclear Information System (INIS)

    George, T.G.; Pavone, D.

    1986-05-01

    The General-Purpose Heat Source (GPHS) is a modular component of the radioisotope thermoelectric generator that will provide power for the Galileo and Ulysses (formerly ISPM) space missions. The GPHS provides power by transmitting the heat of 238 Pu α-decay to an array of thermoelectric elements. Because the possibility of an orbital abort always exists, the heat source was designed and constructed to minimize plutonia release in any accident environment. The Safety Verification Test (SVT) series was formulated to evaluate the effectiveness of GPHS plutonia containment after atmospheric reentry and Earth impact. The first two reports (covering SVT-1 through SVT-10) described the results of flat, side-on, and angular module impacts against steel targets at 54 m/s. This report describes flat-on module impacts against concrete and granite targets, at velocities equivalent to or higher than previous SVTs

  4. Composite thermocouples

    International Nuclear Information System (INIS)

    Debeir, R.P.

    1975-01-01

    As a rule, a composite thermocouple is a thermocouple where one or more components (wires, sheath, insulation) differ in kind between the hot junction measurement point and the cold termination with ordinary cables going on to measurement instrumentation. Three categories of such thermocouples are discussed: composite thermocouples having in common the continuity of the thermoelement wires over complete length, and different sheaths and insulation for the high temperature and intermediate temperature parts; those with different thermoelement wires, sheaths, and insulators for the high and intermediate temperature parts; a third category includes the high temperature thermoelements insulated by Al 2 O 3 or BeO and sheathed with a refractory metal, and with the intermediate temperature part made of 2Cr-Al couples, MgO insulated, and stainless steel or inconel sheathed

  5. Thermocouple modeling

    International Nuclear Information System (INIS)

    Fryer, M.O.

    1984-01-01

    The temperature measurements provided by thermocouples (TCs) are important for the operation of pressurized water reactors. During severe inadequate core cooling incidents, extreme temperatures may cause type K thermocouples (TCs) used for core exit temperature monitoring to perform poorly. A model of TC electrical behavior has been developed to determine how TCs react under extreme temperatures. The model predicts the voltage output of the TC and its impedance. A series of experiments were conducted on a length of type K thermocouple to validate the model. Impedance was measured at several temperatures between 22 0 C and 1100 0 C and at frequencies between dc and 10 MHz. The model was able to accurately predict impedance over this wide range of conditions. The average percentage difference between experimental data and the model was less than 6.5%. Experimental accuracy was +-2.5%. There is a sriking difference between impedance versus frequency plots at 300 0 C and at higher temperatures. This may be useful in validating TC data during accident conditions

  6. SVT: an online silicon vertex tracker for the CDF upgrade

    International Nuclear Information System (INIS)

    Bardi, A.; Belforte, S.; Berryhill, J.

    1997-07-01

    The SVT is an online tracker for the CDF upgrade which will reconstruct 2D tracks using information from the Silicon VerteX detector (SVXII) and Central Outer Tracker (COT). The precision measurement of the track impact parameter will then be used to select and record large samples of B hadrons. We discuss the overall architecture, algorithms, and hardware implementation of the system

  7. Thin film ceramic thermocouples

    Science.gov (United States)

    Gregory, Otto (Inventor); Fralick, Gustave (Inventor); Wrbanek, John (Inventor); You, Tao (Inventor)

    2011-01-01

    A thin film ceramic thermocouple (10) having two ceramic thermocouple (12, 14) that are in contact with each other in at least on point to form a junction, and wherein each element was prepared in a different oxygen/nitrogen/argon plasma. Since each element is prepared under different plasma conditions, they have different electrical conductivity and different charge carrier concentration. The thin film thermocouple (10) can be transparent. A versatile ceramic sensor system having an RTD heat flux sensor can be combined with a thermocouple and a strain sensor to yield a multifunctional ceramic sensor array. The transparent ceramic temperature sensor that could ultimately be used for calibration of optical sensors.

  8. Students’ Impression towards Science Virtual Test (SVT) on Digestive System Topic

    Science.gov (United States)

    Mahfira, C.; Sanjaya, Y.; Rusyati, L.

    2018-05-01

    During the past few years, technology has significantly support the improvements in assessment.Computer-based test (CBT) comes up as a new type of assessment which offers many benefits. The implementation of computer-based test in term of students’ perspective gives rise to numbers of mixed reactions. Students’ impression is one of the essential things for the implementation of SVT. The purpose of this study was to investigate the impression of students toward SVT. The method used in this research was descriptive method. The participant was 98 students from Junior High School “X” in East Bandung. Students’ impression questionnaire was used as the instrument. There are four aspects tested in this instrument which are students’ experience, technical activity, preference and media of SVT. The result shows that SVT generally gives positive impression to students. Students have a positive experience and did not encounter significant problem when implementing SVT. Students prefer to use SVT and students think the media of SVT is already good.

  9. Travelling gradient thermocouple calibration

    International Nuclear Information System (INIS)

    Broomfield, G.H.

    1975-01-01

    A short discussion of the origins of the thermocouple EMF is used to re-introduce the idea that the Peltier and Thompson effects are indistinguishable from one another. Thermocouples may be viewed as devices which generate an EMF at junctions or as integrators of EMF's developed in thermal gradients. The thermal gradient view is considered the more appropriate, because of its better accord with theory and behaviour, the correct approach to calibration, and investigation of service effects is immediately obvious. Inhomogeneities arise in thermocouples during manufacture and in service. The results of travelling gradient measurements are used to show that such effects are revealed with a resolution which depends on the length of the gradient although they may be masked during simple immersion calibration. Proposed tests on thermocouples irradiated in a nuclear reactor are discussed

  10. Temperature measurements by thermocouples

    International Nuclear Information System (INIS)

    Liermann, J.

    1975-01-01

    The measurement of a temperature (whatever the type of transducer used) raises three problems: the choice of transducer; where it should be placed; how it should be fixed and protected. These are the three main points examined, after a brief description of the most commonly used thermocouples [fr

  11. SILICON DRIFT DETECTORS FOR THE STAR/SVT EXPERIMENT AT RHIC

    International Nuclear Information System (INIS)

    TAKAHASHI, J.

    1998-01-01

    Large area linear Silicon Drift Detectors (SDD) were developed to be used in the Silicon Vertex Tracker (SVT) of the STAR experiment at the BNL relativistic heavy ion collider (RHIC). The SDD is in its final design and has been submitted for large scale production. Test results show that the detector exhibits excellent position resolution and low noise. A special characterization procedure was developed to test detector wafers in order to select good detectors for the SVT. Recently, 15 STAR/SVT SDD's were assembled as a tracking device in a BNL-AGS heavy ion experiment (E896). It is the first tracking application of these detectors and their corresponding front-end electronics in an experimental environment. Preliminary results indicating good detector performance are shown and discussed in this paper

  12. Noncontacting Measurement With a Thermocouple

    Science.gov (United States)

    Weatherill, W. T.; Schoreder, C. J.; Freitag, H. J.

    1986-01-01

    Tentlike covering brings thermocouple to within few degrees of surface temperature. Technique originally developed for measuring surface temperature of quartz fabric under radiant heating requires no direct contact with heated surface. Technique particularly useful when measuring surface temperatures of materials damaged if thermocouple or other temperature sensor attached.

  13. PWR thermocouple mechanical sealing structure

    International Nuclear Information System (INIS)

    Shen Qiuping; He Youguang

    1991-08-01

    The PWR in-core temperature detection device, which is one of measures to insure reactor safety operation, is to monitor and diagnose reactor thermal power output and in-core power distribution. The temperature detection device system uses thermocouples as measuring elements with stainless steel protecting sleeves. The thermocouple has a limited service time and should be replaced after its service time has reached. A new sealing device for the thermocouples of reactor in-core temperature detection system has been developed to facilitate replacement. The structure is complete tight under high temperature and pressure without any leakage and seepage, and easy to be assembled or disassembled in radioactive environment. The device is designed to make it possible to replace the thermocouple one by one if necessary. This is a new, simple and practical structure

  14. Temperature monitoring device and thermocouple assembly therefor

    Science.gov (United States)

    Grimm, Noel P.; Bauer, Frank I.; Bengel, Thomas G.; Kothmann, Richard E.; Mavretish, Robert S.; Miller, Phillip E.; Nath, Raymond J.; Salton, Robert B.

    1991-01-01

    A temperature monitoring device for measuring the temperature at a surface of a body, composed of: at least one first thermocouple and a second thermocouple; support members supporting the thermocouples for placing the first thermocouple in contact with the body surface and for maintaining the second thermocouple at a defined spacing from the body surface; and a calculating circuit connected to the thermocouples for receiving individual signals each representative of the temperature reading produced by a respective one of the first and second thermocouples and for producing a corrected temperature signal having a value which represents the temperature of the body surface and is a function of the difference between the temperature reading produced by the first thermocouple and a selected fraction of the temperature reading provided by the second thermocouple.

  15. Spatial filtring and thermocouple spatial filter

    International Nuclear Information System (INIS)

    Han Bing; Tong Yunxian

    1989-12-01

    The design and study on thermocouple spatial filter have been conducted for the flow measurement of integrated reactor coolant. The fundamental principle of spatial filtring, mathematical descriptions and analyses of thermocouple spatial filter are given

  16. LOFT small break test thermocouple installation

    International Nuclear Information System (INIS)

    Fors, R.M.

    1980-01-01

    The subject thermocouple design has been analyzed for maximum expected hydraulic loading and found to be adequate. The natural frequency of the thermocouple was found to be between the vortex shedding frequencies for the gas and liquid phase so that a tendency for resonance will exist. However, since the thermocouple support will have a restricted displacement, stresses found are below the endurance limit and, thus, are acceptable in respect to fatigue life as well as primary stress due to pressure loading

  17. Novel thermocouples for automotive applications

    Directory of Open Access Journals (Sweden)

    P. Gierth

    2018-02-01

    Full Text Available Measurement of temperatures in engine and exhaust systems in automotive applications is necessary for thermal protection of the parts and optimizing of the combustion process. State-of-the-art temperature sensors are very limited in their response characteristic and installation space requirement. Miniaturized sensor concepts with a customizable geometry are needed. The basic idea of this novel sensor concept is to use thick-film technology on component surfaces. Different standardized and especially nonstandard material combinations of thermocouples have been produced for the validation of this technology concept. Application-oriented measurements took place in the exhaust system of a test vehicle and were compared to standard laboratory conditions.

  18. Attaching Thermocouples by Peening or Crimping

    Science.gov (United States)

    Murtland, Kevin; Cox, Robert; Immer, Christopher

    2006-01-01

    Two simple, effective techniques for attaching thermocouples to metal substrates have been devised for high-temperature applications in which attachment by such conventional means as welding, screws, epoxy, or tape would not be effective. The techniques have been used successfully to attach 0.005- in. (0.127-mm)-diameter type-S thermocouples to substrates of niobium alloy C-103 and stainless steel 416 for measuring temperatures up to 2,600 F (1,427 C). The techniques are equally applicable to other thermocouple and substrate materials. In the first technique, illustrated in the upper part of the figure, a hole slightly wider than twice the diameter of one thermocouple wire is drilled in the substrate. The thermocouple is placed in the hole, then the edge of the hole is peened in one or more places by use of a punch (see figure). The deformed material at the edge secures the thermocouple in the hole. In the second technique a hole is drilled as in the first technique, then an annular relief area is machined around the hole, resulting in structure reminiscent of a volcano in a crater. The thermocouple is placed in the hole as in the first technique, then the "volcano" material is either peened by use of a punch or crimped by use of sidecutters to secure the thermocouple in place. This second technique is preferable for very thin thermocouples [wire diameter .0.005 in. (.0.127 mm)] because standard peening poses a greater risk of clipping one or both of the thermocouple wires. These techniques offer the following advantages over prior thermocouple-attachment techniques: . Because these techniques involve drilling of very small holes, they are minimally invasive . an important advantage in that, to a first approximation, the thermal properties of surrounding areas are not appreciably affected. . These techniques do not involve introduction of any material, other than the substrate and thermocouple materials, that could cause contamination, could decompose, or oxidize

  19. AGR-1 Thermocouple Data Analysis

    International Nuclear Information System (INIS)

    Einerson, Jeff

    2012-01-01

    This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R and D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of

  20. AGR-1 Thermocouple Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jeff Einerson

    2012-05-01

    This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R&D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of

  1. Thermocouple pressure bushing in suspension rod

    International Nuclear Information System (INIS)

    Pasek, J.; Ondreicka, K.

    1975-01-01

    The seal is described of jacket thermocouples located in the pressure reducer in the fuel element suspension rod. The thermocouples are sealed in the pressure reducer with a silicon sealing compound. The sealing compound is compressed between the two reducers with a Bellevile spring and a pressure washer secured in position with a spring. The axial pressure of the inner parts of the reducer on the compound is adjustable by means of a thrust screw. The tightness and alignment of the thermocouples in the pressure reducer is achieved by tightening the thrust screw to the stop of the top reducer and the subsequent setting of the sealing compound. (J.B.)

  2. Characteristics of metal sheathed thermocouples in thermowell

    International Nuclear Information System (INIS)

    Okuda, Takehiro; Nakase, Tsuyoshi; Tanabe, Yutaka; Yamada, Kunitaka; Yoshizaki, Akio; Roko, Kiyokazu

    1987-01-01

    Static and dynamic characteristics of thermowell type thermocouples which are planned to be used for the High-Temperature engineering Test Reactor (HTTR) have been investigated. A mock-up test section was installed in Kawasaki's Helium Test Loop (KH-200). Thermal characteristics tests were carried out under the 600 ∼ 1000 deg C temperature conditions. The test section was equipped with four types sheathed thermocouples; the well type, the non well type, and ones with and without the thermal radiation shielding plate. The measured temperature by the well type thermocouples with the shielding plate was only about 1.3 deg C higher than the one without the shielding plate at gas temperature 990 deg C. The measured time constant of the well type thermocouples was about 7 seconds in the condition of the heat transfer coefficient 1600 Kcal/m 2 h deg C on the well surface, and coincided with the calculated one by ''TRUMP'' code. (author)

  3. Operating problems of the thermocouples in VVER

    International Nuclear Information System (INIS)

    Timonin, A.S.

    1997-01-01

    In WWER reactors, the coolant temperature at the outlet of the majority of fuel assemblies is measured with chromel-alumel cable thermocouples. The components of systematic errors in temperature measurements are discussed. Errors due to calibration drift can be avoided by periodical calibrations performed during the heating and hot test runs after reactor refueling. Errors due to radiation heating and response time can be estimated and thus eliminated. Errors due to flow stratification of the coolant can also be eliminated by an estimation of correction factors. The effects of the aging of the thermocouples are also discussed. The removal of thermocouples from their coverings for replacement presents some difficulties, which thus determine the service life of the thermocouples. (A.K.)

  4. Estimation of radiation losses from sheathed thermocouples

    International Nuclear Information System (INIS)

    Roberts, I.L.; Coney, J.E.R.; Gibbs, B.M.

    2011-01-01

    Thermocouples are often used for temperature measurements in heat exchangers. However if the radiation losses from a thermocouple in a high temperature gas flow to colder surroundings are ignored significant errors can occur. Even at moderate temperature differences, these can be significant. Prediction of radiation losses from theory can be problematic, especially in situations where there are large variations in the measured temperatures as the emissivity and radiative heat transfer coefficient of the thermocouple are not constant. The following approach combines experimental results with established empirical relationships to estimate losses due to radiation in an annular heat exchanger at temperatures up to 950 o C. - Highlights: → Sheathed thermocouples are often used to measure temperatures in heat exchangers. → Errors are introduced if radiation losses are ignored. → Radiation losses are environment specific and may be significant. → Experimental and theoretical methods are used to estimate losses. → Hot side maximum temperature 950 o C.

  5. Self-adapted thermocouple-diagnostic complex

    International Nuclear Information System (INIS)

    Alekseev, S.V.; Grankovskij, K.Eh.; Olejnikov, P.P.; Prijmak, S.V.; Shikalov, V.F.

    2003-01-01

    A self-adapted thermocouple-diagnostic complex (STDC) for obtaining the reliable data on the coolant temperature in the reactors of NPP is described. The STDC in based on the thermal pulse monitoring of a thermocouple in the measuring channel of a reactor. Measurement method and STDC composition are substantiated. It is shown that introduction of the developed STDC ensures realization of precise and reliable temperature monitoring in the reactors of all types [ru

  6. Embedded cladding surface thermocouples on Zircaloy-sheathed heater rods

    International Nuclear Information System (INIS)

    Wilkins, S.C.

    1977-06-01

    Titanium-sheathed Type K thermocouples embedded in the cladding wall of zircaloy-sheathed heater rods are described. These thermocouples constitute part of a program intended to characterize the uncertainty of measurements made by surface-mounted cladding thermocouples on nuclear fuel rods. Fabrication and installation detail, and laboratory testing of sample thermocouple installations are included

  7. Adhesive-Bonded Tab Attaches Thermocouples to Titanium

    Science.gov (United States)

    Cook, C. F.

    1982-01-01

    Mechanical strength of titanium-alloy structures that support thermocouples is preserved by first spotwelding thermocouples to titanium tabs and then attaching tabs to titanium with a thermosetting adhesive. In contrast to spot welding, a technique previously used for thermocouples, fatigue strength of the titanium is unaffected by adhesive bonding. Technique is also gentler than soldering or attaching thermocouples with a tap screw.

  8. Study on thermocouple attachment in reflood experiments

    International Nuclear Information System (INIS)

    Sugimoto, Jun

    1977-03-01

    The method of thermocouple attachment to a heater rods has been studied for surface temperature measurement in reflood experiments. The method used as far in JAERI's reflood experiments had some possibilities of not estimating exactly the quench times. Various attachment method have been tested and some proved to be effective in the respect. (auth.)

  9. A thermocouple thermometry system for ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Ozarka, M.; Gharakhani, A.; Magin, R.; Cain, C.

    1984-01-01

    A thermometry system designed to be used in the treatment of cancer by ultrasound hyperthermia is described. The system monitors tumor temperatures using 16 type T (copper-constantan) thermocouples and is controlled by a 12 MHz Intel 8031 microcomputer. An analog circuit board contains the thermocouple amplifiers, an analog multiplexer, scaling circuitry, and an analog to digital converter. A digital board contains the Intel 8031, program memory, data memory, as well as circuitry for control and data communications. Communication with the hyperthermia system control computer is serially by RS-232 with selectable baud rate. Since the thermocouple amplifiers may have slight differences in gain and offset, a calibrated offset is added to a lookup table value to obtain the proper display temperature to within +- 0.1 0 C. The calibration routine, implemented in software, loads a nonvolatile random access memory chip with the proper offset values based on the outputs of each thermocouple channel at known temperatures which bracket a range of interest

  10. Technological improvements to high temperature thermocouples for nuclear reactor applications

    International Nuclear Information System (INIS)

    Schley, R.; Leveque, J.P.

    1980-07-01

    The specific operating conditions of thermocouples in nuclear reactors have provided an incentive for further advances in high temperature thermocouple applications and performance. This work covers the manufacture and improvement of existing alloys, the technology of clad thermocouples, calibration drift during heat treatment, resistance to thermal shock and the compatibility of insulating materials with thermo-electric alloys. The results lead to specifying improved operating conditions for thermocouples in nuclear reactor media (pressurized water, sodium, uranium oxide) [fr

  11. The application of self-validation to wireless sensor networks

    International Nuclear Information System (INIS)

    Collett, Michael A; Cox, Maurice G; Esward, Trevor J; Harris, Peter M; Duta, Mihaela; Henry, Manus P

    2008-01-01

    Self-validation is a valuable tool for extending the operating range of sensing systems and making them more robust. Wireless sensor networks suffer many limitations meaning that their efficacy could be greatly improved by self-validation techniques. We present two independently developed data analysis techniques and demonstrate that they can be applied to a wireless sensor network. Using an acoustic ranging application we demonstrate an improvement of more than ten-fold in the uncertainty of a single measurement where multiple sensor readings are appropriately combined. We also demonstrate that of the two methods for determining a largest consistent subset one is more rigorous in dealing with correlation, and the other more suited to time-series data

  12. Thermocouples for conditions of aggressive environments

    International Nuclear Information System (INIS)

    Blanc, J.Y.

    1988-01-01

    Two new kinds of thermocouples have been chosen for temperature measurements in the in-pile safety program for light water reactors performed in France. They must give fuel centerline or roc cladding temperatures and withstand steam oxidation between 1000 0 C and 1800 0 C or higher, under severe fuel damage conditions. We describe briefly both types, then we emphasize on improvements under way concerning the tungsten-rhenium legs, the hafnia insulation and the sheaths materials. Oxidation resistance is achieved mainly by silicides layers, but other possibilities are considered, such as iridium coatings. Some details of insulators manufacturing or sensor assembly are given, as well as other high temperature applications for these thermocouples

  13. Core exit thermocouple upgrade at Zion station

    International Nuclear Information System (INIS)

    Ulinski, T.M.; Ferg, D.A.

    1989-01-01

    Following the Three Mile Island accident, the ability of the core exit thermocouple (CET) system to monitor reactor core conditions and core cooling status became a requirement of the U.S. Nuclear Regulatory Commission (NRC). Since the thermocouple system at Zion station was not originally required for postaccident monitoring, Commonwealth Edison Company (CECo) committed to upgrading the CET system and to installing a subcooling margin monitoring (SMM) system. The significance of this commitment was that CECo proposed to accomplish the upgrade effort using internal resources and by developing the required in-house expertise instead of procuring integrated packages from several nuclear steam supply system vendors. The result was that CECo was able to demonstrate a number of new capabilities and unique design features with a significant cost savings. These included a qualified connector with an integral thermocouple cold-reference junction temperature compensation; the design, assembly, testing, and installation of a seismically qualified class 1E microprocessor; a commercial-grade dedication/upgrade process for safety-related hardware; a human factors review capability, and a verification and validation program for safety-related software. A discussion of these new capabilities and details of the design features is presented in this paper

  14. Gene expression profiling: cell cycle deregulation and aneuploidy do not cause breast cancer formation in WAP-SVT/t transgenic animals.

    Science.gov (United States)

    Klein, Andreas; Guhl, Eva; Zollinger, Raphael; Tzeng, Yin-Jeh; Wessel, Ralf; Hummel, Michael; Graessmann, Monika; Graessmann, Adolf

    2005-05-01

    Microarray studies revealed that as a first hit the SV40 T/t antigen causes deregulation of 462 genes in mammary gland cells (ME cells) of WAP-SVT/t transgenic animals. The majority of deregulated genes are cell proliferation specific and Rb-E2F dependent, causing ME cell proliferation and gland hyperplasia but not breast cancer formation. In the breast tumor cells a further 207 genes are differentially expressed, most of them belonging to the cell communication category. In tissue culture breast tumor cells frequently switch off WAP-SVT/t transgene expression and regain the morphology and growth characteristics of normal ME cells, although the tumor-revertant cells are aneuploid and only 114 genes regain the expression level of normal ME cells. The profile of retransformants shows that only 38 deregulated genes are tumor-specific, and that none of them is considered to be a typical breast cancer gene.

  15. Zircaloy sheathed thermocouples for PWR fuel rod temperature measurements

    International Nuclear Information System (INIS)

    Anderson, J.V.; Wesley, R.D.; Wilkins, S.C.

    1979-01-01

    Small diameter zircaloy sheathed thermocouples have been developed by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. Surface mounted thermocouples were developed to measure the temperature of zircaloy clad fuel rods used in the Thermal Fuels Behavior Program (TFBP), and embedded thermocouples were developed for use by the Loss-of-Fluid Test (LOFT) Program for support tests using zircaloy clad electrically heated nuclear fuel rod simulators. The first objective of this developmental effort was to produce zircaloy sheathed thermocouples to replace titanium sheathed thermocouples and thereby eliminate the long-term corrosion of the titanium-to-zircaloy attachment weld. The second objective was to reduce the sheath diameter to obtain faster thermal response and minimize cladding temperature disturbance due to thermocouple attachment

  16. Error analysis of thermocouple measurements in the Radiant Heat Facility

    International Nuclear Information System (INIS)

    Nakos, J.T.; Strait, B.G.

    1980-12-01

    The measurement most frequently made in the Radiant Heat Facility is temperature, and the transducer which is used almost exclusively is the thermocouple. Other methods, such as resistance thermometers and thermistors, are used but very rarely. Since a majority of the information gathered at Radiant Heat is from thermocouples, a reasonable measure of the quality of the measurements made at the facility is the accuracy of the thermocouple temperature data

  17. Transmutation of Thermocouples in Thermal and Fast Nuclear Reactors

    International Nuclear Information System (INIS)

    Scervini, M.; Rae, C.; Lindley, B.

    2013-06-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. Their role is fundamental for the control of current nuclear reactors and for the development of the nuclear technology needed for the implementation of GEN IV nuclear reactors. When used for in-core measurements thermocouples are strongly affected not only by high temperatures, but also by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition in the thermoelements and, as a consequence, a time dependent drift in the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. In this work, undertaken as part of the European project METROFISSION, the change in composition occurring in irradiated thermocouples has been calculated using the software ORIGEN 2.2. Several thermocouples have been considered, including Nickel based thermocouples (type K and type N), Tungsten based thermocouples (W-5%Re vs W-26%Re and W- 3%Re vs W-25%Re), Platinum based thermocouples (type S and Platinum vs Palladium) and Molybdenum vs Niobium thermocouples. The transmutation induced by both thermal flux and fast flux has been calculated. Thermocouples undergo more pronounced transmutation in thermal fluxes rather than in fast fluxes, as the neutron cross section of an element is higher for thermal energies. Nickel based thermocouples have a minimal change in composition, while Platinum based and Tungsten based thermocouples experience a very significant transmutation. The use of coatings deposited on the sheath of a thermocouple has been considered as a mean to reduce the neutron flux the thermoelements inside the thermocouple sheath

  18. Fabrication and use of zircaloy/tantalum-sheathed cladding thermocouples and molybdenum/rhenium-sheathed fuel centerline thermocouples

    International Nuclear Information System (INIS)

    Wilkins, S.C.; Sepold, L.K.

    1985-01-01

    The thermocouples described in this report are zircaloy/tantalum-sheathed and molybdenum/rhenium alloy-sheathed instruments intended for fuel rod cladding and fuel centerline temperature measurements, respectively. Both types incorporate beryllium oxide insulation and tungsten/rhenium alloy thermoelements. These thermocouples, operated at temperatures of 2000 0 C and above, were developed for use in the internationally sponsored Severe Fuel Damage test series in the Power Burst Facility. The fabrication steps for both thermocouple types are described in detail. A laser-welding attachment technique for the cladding-type thermocouple is presented, and experience with alternate materials for cladding and fuel therocouples is discussed

  19. Low Drift Type N Thermocouples for Nuclear Applications

    International Nuclear Information System (INIS)

    Scervini, M.; Rae, C.

    2013-06-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. In this work, undertaken as part of the European project METROFISSION, the drift of type N thermocouples has been investigated in the temperature range 600-1300 deg. C. The approach of this study is based on the attempt to separate the contributions of each thermo-element to drift. In order to identify the dominant thermo-element for drift, the contributions of both positive (NP) and negative (NN) thermo-elements to the total drift of 3.2 mm diameter MIMS thermocouples have been measured in each drift test using a pure Pt thermo-element as a reference. Conventional Inconel-600 sheathed type N thermocouples have been compared with type N thermocouples sheathed in a new alloy. At temperatures higher than 1000 deg. C conventional Inconel600 sheathed type N thermocouples can experience a

  20. Sputtered type s thermocouples on quartz glass substrates

    International Nuclear Information System (INIS)

    Sopko, B.; Vlk, J.; Chren, D.; Sopko, V.; Dammer, J.; Mengler, J.; Hynek, V.

    2011-01-01

    The work deals with the development of thin film thermocouples and their practical use. The principle of measuring planar thin film thermocouples is the same as for conventional thermocouples and is based on the thermoelectric effect, which named after its discoverer, Seebeck. Seebeck effect is direct conversion of temperature differences to electric voltage. In different applications it is necessary to use temperature sensors with high spatial resolution (with the placement of several measured points on the segment of length 1 mm) and short response time. For this application are currently used planar thermocouples with important advantage in production price and reproducible production. The innovative potential of thin-film thermocouples are to be found mainly in: 1 st use of technology in thin layers, unlike the already mature technologies applied in the production of conventional thermocouple probes are capable of further improvement with the usage of new substrate materials, modified methods for creating electrical contacts to the new thermocouple configuration and adhesive and protective layers, 2 nd in saving precious and rare metals, 3 rd decreasing the thickness of the layers and reducing the overall size of thermo probe. Measuring the temperature of molten steel, leading to a general loss of strength and the subsequent destruction of the probe. Here exhibited the highest resistance of quartz plates used in thin film substrates thermocouples. (authors)

  1. Thermocouple design for measuring temperatures of small insects

    Science.gov (United States)

    A.A. Hanson; R.C. Venette

    2013-01-01

    Contact thermocouples often are used to measure surface body temperature changes of insects during cold exposure. However, small temperature changes of minute insects can be difficult to detect, particularly during the measurement of supercooling points. We developed two thermocouple designs, which use 0.51 mm diameter or 0.127 mm diameter copper-constantan wires, to...

  2. Thermocouple correlation transit time flowmeter tests at WCL

    International Nuclear Information System (INIS)

    Lassahn, G.D.

    1976-11-01

    Scoping tests indicate the feasibility for using transit time flowmeters with thermocouple sensors in steam-water steady state flow. Conclusive results were not obtained. More conclusive results are expected from tests to be conducted in the semiscale facility with a redesigned transit time thermocouple sensor

  3. Overt head movements and persuasion: a self-validation analysis.

    Science.gov (United States)

    Briñol, Pablo; Petty, Richard E

    2003-06-01

    The authors report 3 experiments that examine a new mechanism by which overt head movements can affect attitude change. In each experiment, participants were induced to either nod or to shake their heads while listening to a persuasive message. When the message arguments were strong, nodding produced more persuasion than shaking. When the arguments were weak, the reverse occurred. These effects were most pronounced when elaboration was high. These findings are consistent with the "self-validation" hypothesis that postulates that head movements either enhance (nodding) or undermine (shaking) confidence in one's thoughts about the message. In a 4th experiment, the authors extended this result to another overt behavior (writing with the dominant or nondominant hand) and a different attitude domain (self-esteem).

  4. Base metal thermocouples drift rate dependence from thermoelement diameter

    International Nuclear Information System (INIS)

    Pavlasek, P; Duris, S; Palencar, R

    2015-01-01

    Temperature measurements are one of the key factors in many industrial applications that directly affect the quality, effectiveness and safety of manufacturing processes. In many industrial applications these temperature measurements are realized by thermocouples. Accuracy of thermocouples directly affects the quality of the final product of manufacturing and their durability determines the safety margins required. One of the significant effects that affect the precision of the thermocouples is short and long term stability of their voltage output. This stability issue occurs in every type of thermocouples and is caused by multiple factors. In general these factors affect the Seebeck coefficient which is a material constant, which determines the level of generated voltage when exposed to a temperature gradient. Changes of this constant result in the change of the thermocouples voltage output thus indicated temperature which can result in production quality issues, safety and health hazards. These alternations can be caused by physical and chemical changes within the thermocouple lead material. Modification of this material constant can be of temporary nature or permanent. This paper concentrates on the permanent, or irreversible changes of the Seebeck coefficient that occur in commonly used swaged MIMS Type N thermocouples. These permanent changes can be seen as systematic change of the EMF of the thermocouple when it is exposed to a high temperature over a period of time. This change of EMF by time is commonly known as the drift of the thermocouple. This work deals with the time instability of thermocouples EMF at temperatures above 1200 °C. Instability of the output voltage was taken into relation with the lead diameter of the tested thermocouples. This paper concentrates in detail on the change of voltage output of thermocouples of different diameters which were tested at high temperatures for the overall period of more than 210 hours. The gather data from this

  5. Base metal thermocouples drift rate dependence from thermoelement diameter

    Science.gov (United States)

    Pavlasek, P.; Duris, S.; Palencar, R.

    2015-02-01

    Temperature measurements are one of the key factors in many industrial applications that directly affect the quality, effectiveness and safety of manufacturing processes. In many industrial applications these temperature measurements are realized by thermocouples. Accuracy of thermocouples directly affects the quality of the final product of manufacturing and their durability determines the safety margins required. One of the significant effects that affect the precision of the thermocouples is short and long term stability of their voltage output. This stability issue occurs in every type of thermocouples and is caused by multiple factors. In general these factors affect the Seebeck coefficient which is a material constant, which determines the level of generated voltage when exposed to a temperature gradient. Changes of this constant result in the change of the thermocouples voltage output thus indicated temperature which can result in production quality issues, safety and health hazards. These alternations can be caused by physical and chemical changes within the thermocouple lead material. Modification of this material constant can be of temporary nature or permanent. This paper concentrates on the permanent, or irreversible changes of the Seebeck coefficient that occur in commonly used swaged MIMS Type N thermocouples. These permanent changes can be seen as systematic change of the EMF of the thermocouple when it is exposed to a high temperature over a period of time. This change of EMF by time is commonly known as the drift of the thermocouple. This work deals with the time instability of thermocouples EMF at temperatures above 1200 °C. Instability of the output voltage was taken into relation with the lead diameter of the tested thermocouples. This paper concentrates in detail on the change of voltage output of thermocouples of different diameters which were tested at high temperatures for the overall period of more than 210 hours. The gather data from this

  6. Heated junction thermocouple level measurement apparatus

    International Nuclear Information System (INIS)

    Bevilacqua, F.; Burger, J.M.

    1984-01-01

    A liquid level sensing apparatus senses the level of liquid surrounding the apparatus. A plurality of axially spaced sensors are enclosed in a separator tube. The separator tube tends to collapse the level of a two-phase fluid within the separator tube into essentially a liquid phase and a gaseous phase where the collapsed level bears a relationship to the coolant inventory outside the separator tube. The level of the liquid phase is sensed by level sensing apparatus. The separator tube contains inlet-outlet ports near the top and bottom thereof to equalize the liquid level inside and outside the separator tube when the level fluctuates or the water within the separator tube flashes to steam. Each sensor is comprised of a heater, a heated thermocouple junction and an unheated thermocouple junction within an elongated heat conductive housing. The heated portion of housing is enclosed in a splash guard with inlet-outlet ports near the top and bottom to equalize the liquid level inside and outside the splash guardand to eliminate the spurious indications of liquid level change which may arise if water droplets contact the housing in the region of the heater. To prevent steam bubbles entrained in a two-phase fluid cross flow from entering the lateral inlet-outlet ports of the separator tube, the separator tube is enclosed in support tube which may in turn be enclosed in an otherwise unused control element assembly shroud. The lateral inlet-outlet ports of separator tube are axially offset from lateral inlet-outlet ports of support tube at least where support tube is subjected to cross flow. The shroud is open on the bottom and has lateral inlet-outlet ports to facilitate liquid level fluctuations to equalize inside and outside shroud

  7. Study of thermocouples for control of high temperatures

    International Nuclear Information System (INIS)

    Villamayor, M.

    1966-12-01

    Previous works have shown that the tungsten-rhenium alloys thermocouples were a good instrument for control of high temperatures. From its, the author has studied the W/W 26 per cent and W 5 per cent Re/W 26 per cent Re french manufactured thermocouples and intended for control of temperatures in nuclear reactors until 2300 deg. C. In 'out-pile' study he determines the general characteristics of these thermocouples: average calibration curves, thermal shocks influence, response times, and alloys allowing the cold source compensation. The evolution of these thermocouples under thermal neutron flux has been determined by 'in-pile' study. The observations have led the author to propose a new type of thermocouples settled of molybdenum-columbium alloys. (author) [fr

  8. Thermocouple evaluation model and evaluation of chromel--alumel thermocouples for High-Temperature Gas-Cooled Reactor applications

    International Nuclear Information System (INIS)

    Washburn, B.W.

    1977-03-01

    Factors affecting the performance and reliability of thermocouples for temperature measurements in High-Temperature Gas-Cooled Reactors are investigated. A model of an inhomogeneous thermocouple, associated experimental technique, and a method of predicting measurement errors are described. Error drifts for Type K materials are predicted and compared with published stability measurements. 60 references

  9. Study of thermocouples for control of high temperatures; Etude de thermocouples pour le reperage des hautes temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Villamayor, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Faculte des Sciences de l' Universite de Lyon - 69 (France)

    1967-07-01

    Previous works have shown that the tungsten-rhenium alloys thermocouples were a good instrument for control of high temperatures. From its, the author has studied the W/W 26 per cent and W 5 per cent Re/W 26 per cent Re french manufactured thermocouples and intended for control of temperatures in nuclear reactors until 2300 deg. C. In 'out-pile' study he determines the general characteristics of these thermocouples: average calibration curves, thermal shocks influence, response times, and alloys allowing the cold source compensation. The evolution of these thermocouples under thermal neutron flux has been determined by 'in-pile' study. The observations have led the author to propose a new type of thermocouples settled of molybdenum-columbium alloys. (author) [French] Des travaux anterieurs ont montre que les thermocouples des alliages tungstene-rhenium etaient susceptibles de reperer avec precision des hautes temperatures. A partir de la, l'auteur a etudie las thermocouples W/W 26 pour cent Re et W 5 pour cent Re/W 26 pour cent Re de fabrication francaise et destines au controle des temperatures dans les reacteurs nucleaires, jusqu'a 2300 deg. C Dans l'etude 'hors-pile' il a determine les caracteristiques generales de ces thermocouples: courbes d'etalonnage moyen, influence des chocs thermiques, temps de reponse, et alliages assurant la compensation de soudure froide. L'etude 'en-pile' a permis de rendre compte de l'evolution de ces thermocouples sous flux neutroniques. Les phenomenes observes ont conduit l'auteur a proposer un nouveau type de thermocouples constitues d'alliages molybdene-niobium. (auteur)

  10. The SVT Hit Buffer

    International Nuclear Information System (INIS)

    Belforte, S.; Dell'Orso, M.; Donati, S.

    1996-01-01

    The Hit Buffer is part of the Silicon Vertex Tracker, a trigger processor dedicated to the reconstruction of particle trajectories in the Silicon Vertex Detector and the Central Tracking Chamber of the Collider Detector at Fermilab. The Hit Buffer is a high speed data-traffic node, where thousands of words are received in arbitrary order and simultaneously organized in an internal structured data base, to be later promptly retrieved and delivered in response to specific requests. The Hit Buffer is capable of processing data at a rate of 25 MHz, thanks to the use of special fast devices like Cache-Tag RAMs and high performance Erasable Programmable Logic Devices from the XILINX XC7300 family

  11. Metallic and Ceramic Thin Film Thermocouples for Gas Turbine Engines

    Directory of Open Access Journals (Sweden)

    Otto J. Gregory

    2013-11-01

    Full Text Available Temperatures of hot section components in today’s gas turbine engines reach as high as 1,500 °C, making in situ monitoring of the severe temperature gradients within the engine rather difficult. Therefore, there is a need to develop instrumentation (i.e., thermocouples and strain gauges for these turbine engines that can survive these harsh environments. Refractory metal and ceramic thin film thermocouples are well suited for this task since they have excellent chemical and electrical stability at high temperatures in oxidizing atmospheres, they are compatible with thermal barrier coatings commonly employed in today’s engines, they have greater sensitivity than conventional wire thermocouples, and they are non-invasive to combustion aerodynamics in the engine. Thin film thermocouples based on platinum:palladium and indium oxynitride:indium tin oxynitride as well as their oxide counterparts have been developed for this purpose and have proven to be more stable than conventional type-S and type-K thin film thermocouples. The metallic and ceramic thin film thermocouples described within this paper exhibited remarkable stability and drift rates similar to bulk (wire thermocouples.

  12. Evaluation of RTD and thermocouple for PID temperature control in ...

    African Journals Online (AJOL)

    Evaluation of RTD and thermocouple for PID temperature control in distributed control system laboratory. D. A. A. Nazarudin, M. K. Nordin, A. Ahmad, M. Masrie, M. F. Saaid, N. M. Thamrin, M. S. A. M. Ali ...

  13. Long duration performance of high temperature irradiation resistant thermocouples

    International Nuclear Information System (INIS)

    Rempe, J.; Knudson, D.; Condie, K.; Cole, J.; Wilkins, S.C.

    2007-01-01

    Many advanced nuclear reactor designs require new fuel, cladding, and structural materials. Data are needed to characterize the performance of these new materials in high temperature, radiation conditions. However, traditional methods for measuring temperature in-pile degrade at temperatures above 1100 C degrees. To address this instrumentation need, the Idaho National Laboratory (INL) developed and evaluated the performance of a high temperature irradiation-resistant thermocouple that contains alloys of molybdenum and niobium. To verify the performance of INL's recommended thermocouple design, a series of high temperature (from 1200 to 1800 C) long duration (up to six months) tests has been initiated. This paper summarizes results from the tests that have been completed. Data are presented from 4000 hour tests conducted at 1200 and 1400 C that demonstrate the stability of this thermocouple (less than 2% drift). In addition, post test metallographic examinations are discussed which confirm the compatibility of thermocouple materials throughout these long duration, high temperature tests. (authors)

  14. The validation of science virtual test to assess 7th grade students’ critical thinking on matter and heat topic (SVT-MH)

    Science.gov (United States)

    Sya’bandari, Y.; Firman, H.; Rusyati, L.

    2018-05-01

    The method used in this research was descriptive research for profiling the validation of SVT-MH to measure students’ critical thinking on matter and heat topic in junior high school. The subject is junior high school students of 7th grade (13 years old) while science teacher and expert as the validators. The instruments that used as a tool to obtain the data are rubric expert judgment (content, media, education) and rubric of readability test. There are four steps to validate SVT-MH in 7th grade Junior High School. These steps are analysis of core competence and basic competence based on Curriculum 2013, expert judgment (content, media, education), readability test and trial test (limited and larger trial test). The instrument validation resulted 30 items that represent 8 elements and 21 sub-elements to measure students’ critical thinking based on Inch in matter and heat topic. The alpha Cronbach (α) is 0.642 which means that the instrument is sufficient to measure students’ critical thinking matter and heat topic.

  15. Relative humidity measurements with thermocouple psychrometer and capacitance sensors

    International Nuclear Information System (INIS)

    Mao, Naihsien.

    1991-01-01

    The relative humidity is one of the important hydrological parameters affecting waste package performance. Water potential of a system is defined as the amount of work required to reversibly and isothermally move an infinitesimal quantity of water from a pool of pure water to that system at the same elevation. The thermocouple psychrometer, which acts as a wet-dry bulb instrument based on the Peltier effect, is used to measure water potential. The thermocouple psychrometer works only for relative humidity greater than 94 percent. Other sensors must be used for drier conditions. Hence, the author also uses a Vaisala Humicap, which measures the capacitance change due to relative humidity change. The operation range of the Humicap (Model HMP 135Y) is from 0 to 100 percent relative humidity and up to 160C (320F) in temperature. A psychrometer has three thermocouple junctions. Two copper-constantan junctions serve as reference temperature junctions and the constantan-chromel junction is the sensing junction. Current is passed through the thermocouple causing cooling of the sensing junction by the Peltier effect. When the temperature of the junction is below the dew point, water will condense upon the junction from the air. The Peltier current is discontinued and the thermocouple output is recorded as the temperature of the thermocouple returns to ambient. The temperature changes rapidly toward the ambient temperature until it reaches the wet bulb depression temperature. At this point, evaporation of the water from the junction produces a cooling effect upon the junction that offsets the heat absorbed from the ambient surroundings. This continues until the water is depleted and the thermocouple temperature returns to the ambient temperature (Briscoe, 1984). The datalogger starts to take data roughly at the wet bulb depression temperature

  16. Mineral insulated thermocouples - installation in steam generating plant

    International Nuclear Information System (INIS)

    Bridges, W.J.; Brown, J.F.

    1980-01-01

    The main areas of interest considered are Central Station Fossil Fuel fired boilers of around 500 MW capacity, AGR Boilers, and Industrial and Research Development projects. While the requirement for temperature measurement in each of these areas may vary the techniques adopted to overcome installation and protection problems created by thermal, chemical and mechanical hazards remain basically the same. The reasons for temperature measurement are described together with methods of attachment development and procedures for protection of the thermocouple along its route length until its exit from the hazardous environment. These relative accuracies of the different attachments are discussed along with factors influencing the life of the thermocouple. In many instances thermocouple installation is either a once only opportunity and/or an expensive exercise. It is therefore essential to develop and apply an effective quality control system during the installation phase. An effective system is described. Finally, a brief outline of possible future trends is given. (author)

  17. An Innovative Flow-Measuring Device: Thermocouple Boundary Layer Rake

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Wrbanek, John D.; Blaha, Charles A.

    2001-01-01

    An innovative flow-measuring device, a thermocouple boundary layer rake, was developed. The sensor detects the flow by using a thin-film thermocouple (TC) array to measure the temperature difference across a heater strip. The heater and TC arrays are microfabricated on a constant-thickness quartz strut with low heat conductivity. The device can measure the velocity profile well into the boundary layer, about 65 gm from the surface, which is almost four times closer to the surface than has been possible with the previously used total pressure tube.

  18. Magnetic tunnel junction thermocouple for thermoelectric power harvesting

    Science.gov (United States)

    Böhnert, T.; Paz, E.; Ferreira, R.; Freitas, P. P.

    2018-05-01

    The thermoelectric power generated in magnetic tunnel junctions (MTJs) is determined as a function of the tunnel barrier thickness for a matched electric circuit. This study suggests that lower resistance area product and higher tunnel magnetoresistance will maximize the thermoelectric power output of the MTJ structures. Further, the thermoelectric behavior of a series of two MTJs, a MTJ thermocouple, is investigated as a function of its magnetic configurations. In an alternating magnetic configurations the thermovoltages cancel each other, while the magnetic contribution remains. A large array of MTJ thermocouples could amplify the magnetic thermovoltage signal significantly.

  19. Failure of sheathed thermocouples due to thermal cycling

    International Nuclear Information System (INIS)

    Anderson, R.L.; Ludwig, R.L.

    1982-03-01

    Open circuit failures (up to 100%) in small-diameter thermocouples used in electrically heated nuclear fuel rod simulator prototypes during thermal cycling tests were investigated to determine the cause(s) of the failures. The experiments conducted to determine the relative effects of differential thermal expansion, wire size, grain size, and manufacturing technology are described. It was concluded that the large grain size and embrittlement which result from certain common manufacturing annealing and drawing procedures were a major contributing factor in the breakage of the thermocouple wires

  20. Heat penetration and thermocouple location in home canning.

    Science.gov (United States)

    Etzel, Mark R; Willmore, Paola; Ingham, Barbara H

    2015-01-01

    We processed applesauce, tomato juice, and cranberries in pint jars in a boiling water canner to test thermal processing theories against home canning of high-acid foods. For each product, thermocouples were placed at various heights in the jar. Values for f h (heating), f cl (cooling), and F 82.2°C (lethality) were determined for each thermocouple location, and did not depend substantially on thermocouple location in accordance with heat transfer theory. There was a cold spot in the jar, but the cold spot during heating became the hot spot during cooling. During heating, the geometric center was the last to heat, and remained coldest the longest, but during coooling, it was also the last to cool, and remained hottest the longest. The net effect was that calculated lethality in home canning was not affected by thermocouple location. Most of the lethality during home canning occurred during air cooling, making cooling of home canned foods of great importance. Calculated lethality was far greater than the required 5-log reduction of spores in tomato juice and vegetative cells in cranberries, suggesting a wide margin of safety for approved home-canning processes for high-acid foods.

  1. Realization of Copper Melting Point for Thermocouple Calibrations

    Directory of Open Access Journals (Sweden)

    Y. A. ABDELAZIZ

    2011-08-01

    Full Text Available Although the temperature stability and uncertainty of the freezing plateau is better than that of the melting plateau in most of the thermometry fixed points, but realization of melting plateaus are easier than that of freezing plateaus for metal fixed points. It will be convenient if the melting points can be used instead of the freezing points in calibration of standard noble metal thermocouples because of easier realization and longer plateau duration of melting plateaus. In this work a comparison between the melting and freezing points of copper (Cu was carried out using standard noble metal thermocouples. Platinum - platinum 10 % rhodium (type S, platinum – 30 % rhodium / platinum 6 % rhodium (type B and platinum - palladium (Pt/Pd thermocouples are used in this study. Uncertainty budget analysis of the melting points and freezing points is presented. The experimental results show that it is possible to replace the freezing point with the melting point of copper cell in the calibration of standard noble metal thermocouples in secondary-level laboratories if the optimal methods of realization of melting points are used.

  2. The development of a fast response thermocouple for use in liquid metals

    International Nuclear Information System (INIS)

    Morss, A.G.; Vincent, B.

    1987-03-01

    Work carried out at Berkeley Nuclear Laboratories to develop a fast-response thermocouple for use in liquid metals is described. This thermocouple because of its unique construction, has a junction mass approaching zero and hence its frequency response should be very high. Some of the problems of manufacture are discussed, in particular the high quality of seal required to avoid ingress of liquid metal. A comparison of results obtained with the fast-response thermocouple and with conventional stainless-steel-sheathed thermocouples is made. The improved response of the new thermocouple is clearly visible, hence confirming that measurements made with sheathed thermocouples suffer attenuation. It is concluded that results obtained with the fast-response thermocouple are close to the real magnitude of temperature fluctuations present in turbulent flow. It is also demonstrated that, with suitable corrections, results obtained with sheathed thermocouples can be used to estimate the real signals present in the flow. (author)

  3. Zircaloy-sheathed element rods fitted with thermo-couples

    International Nuclear Information System (INIS)

    Bernardy de Sigoyer, B.; Jacques, F.; Thome, P.

    1963-01-01

    In order to carry out thermal conductivity measurements on UO 2 in conditions similar to those under which fuel rods are used, it was necessary to measure the temperature at the interior of a fuel element sheathed in zircaloy. The temperatures are taken with Thermocoax type thermocouples, that is to say fitted with a very thin sheath of stainless steel or Inconel. It is known also that fusion welding of zircaloy onto stainless steel is impossible and that high temperature welded joints are very difficult because of their aggressiveness. The technique used consists in brazing the thermocouples to relatively large stainless steel parts and then joining these plugs by electron bombardment welding to diffused stainless steel-zircaloy couplings. The properties of these diffused couplings and of the brazed joints were studied; the various stages in the fabrication of the containers are also described. (authors) [fr

  4. Classification of Unknown Thermocouple Types Using Similarity Factor Measurement

    Directory of Open Access Journals (Sweden)

    Seshu K. DAMARLA

    2011-01-01

    Full Text Available In contrast to classification using PCA method, a new methodology is proposed for type identification of unknown thermocouple. The new methodology is based on calculating the degree of similarity between two multivariate datasets using two types of similarity factors. One similarity factor is based on principle component analysis and the angles between the principle component subspaces while the other is based on the Mahalanobis distance between the datasets. Datasets containing thermo-emfs against given temperature ranges are formed for each type of thermocouple (e.g. J, K, S, T, R, E, B and N type by experimentation are considered as reference datasets. Datasets corresponding to unknown type are captured. Similarity factor between the datasets one of which being the unknown type and the other being each known type are compared. When maximum similarity factor occurs, then the class of unknown type is allocated to that of known type.

  5. Recent improvements on micro-thermocouple based SThM

    OpenAIRE

    Nguyen, T. P.; Thiery, L.; Teyssieux, D.; Briand, Danick; Vairac, P.

    2017-01-01

    The scanning thermal microscope (SThM) has become a versatile tool for local surface temperature mapping or measuring thermal properties of solid materials. In this article, we present recent improvements in a SThM system, based on a micro-wire thermocouple probe associated with a quartz tuning fork for contact strength detection. Some results obtained on an electrothermal micro-hotplate device, operated in active and passive modes, allow demonstrating its performance as a coupled force detec...

  6. Thermocouple placement and hot spots in radioactive waste tanks

    International Nuclear Information System (INIS)

    Barker, J.J.

    1991-06-01

    Analytical solutions available in Carslaw and Jaeger's Conduction of Heat in Solids for continuous point sources and for continuous finite sources are used to demonstrate that placement of thermocouples on a fine enough grid to detect a hot spot is impracticable for existing waste tanks but fortunately not necessary. Graphs covering ranges of diffusivities, times, temperatures and heat generation rates are included. 2 refs., 8 figs., 5 tabs

  7. Recommendations for the specification of thermocouples for nuclear applications

    International Nuclear Information System (INIS)

    1977-05-01

    This Code of Practice is a guide for use in the preparation of individual specifications to cover, as fully as possible the conditions governing the supply of raw materials and the ordering, manufacture, testing, inspection, handling and installation of thermocouples for use in nuclear environments in order that reliable, consistent and generally acceptable results can be obtained. The insulation resistance values quoted in this document apply to magnesium oxide. If other insulants are called for, appropriate values must be specified. (author)

  8. Effects of thermocouple installation and location on fuel rod temperature measurements

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1983-01-01

    This paper describes the results of analyses of nuclear fuel rod cladding temperature data obtained during in-reactor experiments under steady state and transient (simulated loss-of-coolant accident) operating conditions. The objective of the analyses was to determine the effect of thermocouple attachment method and location on measured thermal response. The use of external thermocouples increased the time to critical heat flux (CHF), reduced the blowdown peak temperature, and enhanced rod quench. A comparison of laser welded and resistance welded external thermocouple responses showed that the laser welding technique reduced the indicated cladding steady state temperatures and provided shorter time-to-CHF. A comparison of internal welded and embedded thermocouples indicated that the welded technique gave generally unsatisfactory cladding temperature measurements. The embedded thermocouple gave good, consistent results, but was possibly more fragile than the welded thermocouples. Detailed descriptions of the thermocouple designs, attachment methods and locations, and test conditions are provided

  9. Calibration Technique of the Irradiated Thermocouple using Artificial Neural Network

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Tae; Joung, Chang Young; Ahn, Sung Ho; Yang, Tae Ho; Heo, Sung Ho; Jang, Seo Yoon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    To correct the signals, the degradation rate of sensors needs to be analyzed, and re-calibration of sensors should be followed periodically. In particular, because thermocouples instrumented in the nuclear fuel rod are degraded owing to the high neutron fluence generated from the nuclear fuel, the periodic re-calibration process is necessary. However, despite the re-calibration of the thermocouple, the measurement error will be increased until next re-calibration. In this study, based on the periodically calibrated temperature - voltage data, an interpolation technique using the artificial neural network will be introduced to minimize the calibration error of the C-type thermocouple under the irradiation test. The test result shows that the calculated voltages derived from the interpolation function have good agreement with the experimental sampling data, and they also accurately interpolate the voltages at arbitrary temperature and neutron fluence. That is, once the reference data is obtained by experiments, it is possible to accurately calibrate the voltage signal at a certain neutron fluence and temperature using an artificial neural network.

  10. Zircaloy-sheathed element rods fitted with thermo-couples; Barre combustible a thermocouple gainee de zircaloy

    Energy Technology Data Exchange (ETDEWEB)

    Bernardy de Sigoyer, B; Jacques, F; Thome, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    In order to carry out thermal conductivity measurements on UO{sub 2} in conditions similar to those under which fuel rods are used, it was necessary to measure the temperature at the interior of a fuel element sheathed in zircaloy. The temperatures are taken with Thermocoax type thermocouples, that is to say fitted with a very thin sheath of stainless steel or Inconel. It is known also that fusion welding of zircaloy onto stainless steel is impossible and that high temperature welded joints are very difficult because of their aggressiveness. The technique used consists in brazing the thermocouples to relatively large stainless steel parts and then joining these plugs by electron bombardment welding to diffused stainless steel-zircaloy couplings. The properties of these diffused couplings and of the brazed joints were studied; the various stages in the fabrication of the containers are also described. (authors) [French] Pour des mesures de conductivite thermique de l'UO{sub 2} dans des conditions voisines du fonctionnement des barres combustibles, il s'agissait de mesurer la temperature a l'interieur d'un element combustible gaine de zircaloy. Les prises de temperature sont faites par thermocouples du type Thermocoax, c'est-a-dire pourvu d'une gaine tres mince en inox ou inconel. Par ailleurs on sait que le soudage par fusion du zircaloy sur l'inox est impossible et que les brasures a haute temperature sont difficiles car tres agressives. La technique utilisee consiste a braser les thermocouples sur des pieces en inox relativement massives et de rapporter par soudage au bombardement electronique ces bouchons sur des raccords diffuses zircaloy-inox. Les proprietes de ces raccords diffuses et celles de joints brases ont ete etudiees; on expose egalement les diverses etapes de fabrication des containers. (auteurs)

  11. A comprehensive survey of thermoelectric homogeneity of commonly used thermocouple types

    Science.gov (United States)

    Machin, Jonathan; Tucker, Declan; Pearce, Jonathan V.

    2018-06-01

    Thermocouples are widely used as temperature sensors in industry. The electromotive force generated by a thermocouple is produced in a temperature gradient and not at the thermocouple tip. This means that the thermoelectric inhomogeneity represents one of the most important contributions to the overall measurement uncertainty associated with thermocouples. To characterise this effect, and to provide some general recommendations concerning the magnitude of this contribution to use when formulating uncertainty analyses, a comprehensive literature survey has been performed. Significant information was found for Types K, N, R, S, B, Pt/Pd, Au/Pt and various other Pt/Rh thermocouples. In the case of Type K and N thermocouples, the survey has been augmented by a substantial amount of data based on calibrations of mineral-insulated, metal-sheathed thermocouple cable reels from thermocouple manufacturers. Some general conclusions are drawn and outline recommendations given concerning typical values for the uncertainty arising from thermoelectric inhomogeneity for the most widely used thermocouple types in the as-new state. It is stressed that these recommendations should only be heeded when individual homogeneity measurements are not possible. It is also stressed that the homogeneity can deteriorate rapidly during use, particularly for base metal thermocouples.

  12. Characterization of a Method for Inverse Heat Conduction Using Real and Simulated Thermocouple Data

    Science.gov (United States)

    Pizzo, Michelle E.; Glass, David E.

    2017-01-01

    It is often impractical to instrument the external surface of high-speed vehicles due to the aerothermodynamic heating. Temperatures can instead be measured internal to the structure using embedded thermocouples, and direct and inverse methods can then be used to estimate temperature and heat flux on the external surface. Two thermocouples embedded at different depths are required to solve direct and inverse problems, and filtering schemes are used to reduce noise in the measured data. Accuracy in the estimated surface temperature and heat flux is dependent on several factors. Factors include the thermocouple location through the thickness of a material, the sensitivity of the surface solution to the error in the specified location of the embedded thermocouples, and the sensitivity to the error in thermocouple data. The effect of these factors on solution accuracy is studied using the methodology discussed in the work of Pizzo, et. al.1 A numerical study is performed to determine if there is an optimal depth at which to embed one thermocouple through the thickness of a material assuming that a second thermocouple is installed on the back face. Solution accuracy will be discussed for a range of embedded thermocouple depths. Moreover, the sensitivity of the surface solution to (a) the error in the specified location of the embedded thermocouple and to (b) the error in the thermocouple data are quantified using numerical simulation, and the results are discussed.

  13. Stability Studies of a New Design Au/Pt Thermocouple Without a Strain Relieving Coil

    Science.gov (United States)

    Jahan, Ferdouse; Ballico, Mark

    2007-12-01

    The performance of a simple, new design Au/Pt thermocouple developed by NMIA is assessed. This thermocouple is proposed as a more accurate replacement, over the temperature range from 0 to 1,000°C, for the commonly used Type R and S industrial transfer standards, in a robust form familiar to industrial calibration laboratories. Due to the significantly different thermal expansions of the Au and Pt thermoelements, reported designs of the Au/Pt thermocouple incorporate a strain-relieving coil or bridge at the thermocouple junction. As the strain relieving coil is mechanically delicate, these thermocouples are usually mounted in a protective quartz tube assembly, like a standard platinum resistance thermometer (SPRT). Although providing uncertainties at the mK level, they are more delicate than the commonly used Type R and S thermocouples. A new and simple design of the Au/Pt thermocouple was developed in which the differential thermal expansion between Au and Pt is accommodated in the thermocouple leads, facilitated by a special head design. The resulting thermocouple has the appearance and robustness of the traditional Type R and S thermocouples, while retaining stability better than 10 mK up to 961°C. Three thermocouples of this design were calibrated at fixed points and by comparison to SPRTs in a stirred salt bath. In order to assess possible impurity migration, strain effects, and mechanical robustness, sequences of heat treatment up to a total of 500 h together with over 50 thermal cycles from 900°C to ambient were performed. The effect of these treatments on the calibration was assessed, demonstrating the sensors to be robust and stable to better than 10 mK. The effects on the measured inhomogeneity of the thermocouple were assessed using the NMIA thermocouple scanning bath.

  14. Summary of thermocouple performance during advanced gas reactor fuel irradiation experiments in the advanced test reactor and out-of-pile thermocouple testing in support of such experiments

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, A. J.; Haggard, DC; Herter, J. W.; Swank, W. D.; Knudson, D. L.; Cherry, R. S. [Idaho National Laboratory, P.O. Box 1625, MS 4112, Idaho Falls, ID, (United States); Scervini, M. [University of Cambridge, Department of Material Science and Metallurgy, 27 Charles Babbage Road, CB3 0FS, Cambridge, (United Kingdom)

    2015-07-01

    High temperature gas reactor experiments create unique challenges for thermocouple-based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time-dependent change in composition and, as a consequence, a time-dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C). For lower temperature applications, previous experiences with Type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly, Type N thermocouples are expected to be only slightly affected by neutron fluence. Currently, the use of these nickel-based thermocouples is limited when the temperature exceeds 1000 deg. C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past 10 years, three long-term Advanced Gas Reactor experiments have been conducted with measured temperatures ranging from 700 deg. C - 1200 deg. C. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out-of-pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150 deg. C and 1200 deg. C for 2,000 hours at each temperature, followed by 200 hours at 1250 deg. C and 200 hours at 1300 deg. C. The standard Type N design utilizes high purity, crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including a Haynes 214 alloy sheath, spinel (MgAl{sub 2}O{sub 4}) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly

  15. Summary of Thermocouple Performance During Advanced Gas Reactor Fuel Irradiation Experiments in the Advanced Test Reactor and Out-of-Pile Thermocouple Testing in Support of Such Experiments

    Energy Technology Data Exchange (ETDEWEB)

    A. J. Palmer; DC Haggard; J. W. Herter; M. Scervini; W. D. Swank; D. L. Knudson; R. S. Cherry

    2011-07-01

    High temperature gas reactor experiments create unique challenges for thermocouple based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B); and tungsten-rhenium thermocouples (Types C and W). For lower temperature applications, previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of these Nickel based thermocouples is limited when the temperature exceeds 1000°C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past ten years, three long-term Advanced Gas Reactor (AGR) experiments have been conducted with measured temperatures ranging from 700oC – 1200oC. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out of pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150oC and 1200oC for 2000 hours at each temperature, followed by 200 hours at 1250oC, and 200 hours at 1300oC. The standard Type N design utilizes high purity crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including Haynes 214 alloy sheath, spinel (MgAl2O4) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly thermocouple with hard fired alumina

  16. The disposition of can thermocouples in a nuclear reactor

    International Nuclear Information System (INIS)

    Wilkie, D.

    1978-01-01

    A philosophy is presented for deciding the distribution of can thermocouples within channels and of instrumented channels throughout the core of a reactor with cluster-type fuel elements when only a few thermocouples can be located in any one channel. The arrangement is made according to a 'factorial' design in which all fuel element positions of interest are covered in a group of channels. Two types of factorial design can be applied: the unconfounded design by which the thermocouples in each channel are chosen at random from the possible positions available, with the results that the temperatures have attached to them an uncertainty determined by the differences among channels; and the confounded design by which the positions are chosen so as to give temperatures whose uncertainty is determined only by the random variations within channels. It is also necessary to estimate standard deviations in order to predict the number of cans likely to reach a given temperature. The standard deviation can be expected to vary with channel position, and since there will also be systematic variations in temperature with channel position it is necessary to arrange channels into groups having similar mean fluxes and flux distributions. Each group is instrumented according to the pattern of a confounded design. The information that such an arrangement provides is an estimate of the systematic temperature variations within channels, estimates of within-channel variation of can temperature, of between-channel variation of can temperature, and of the variation of these quantities among groups of channels grouped according to similarity of mean flux and flux profile. (author)

  17. Measurement errors for thermocouples attached to thin plates

    International Nuclear Information System (INIS)

    Sobolik, K.B.; Keltner, N.R.; Beck, J.V.

    1989-01-01

    This paper discusses Unsteady Surface Element (USE) methods which are applied to a model of a thermocouple wire attached to a thin disk. Green's functions are used to develop the integral equations for the wire and the disk. The model can be used to evaluate transient and steady state responses for many types of heat flux measurement devices including thin skin calorimeters and circular foil (Gardon) head flux gauges. The model can accommodate either surface or volumetric heating of the disk. The boundary condition at the outer radius of the disk can be either insulated or constant temperature. Effect on the errors of geometrical and thermal factors can be assessed. Examples are given

  18. Recent improvements on micro-thermocouple based SThM

    Science.gov (United States)

    Nguyen, TP; Thiery, L.; Teyssieux, D.; Briand, D.; Vairac, P.

    2017-01-01

    The scanning thermal microscope (SThM) has become a versatile tool for local surface temperature mapping or measuring thermal properties of solid materials. In this article, we present recent improvements in a SThM system, based on a micro-wire thermocouple probe associated with a quartz tuning fork for contact strength detection. Some results obtained on an electrothermal micro-hotplate device, operated in active and passive modes, allow demonstrating its performance as a coupled force detection and thermal measurement system.

  19. Temperature Control System for Chromel-Alumel Thermocouple

    International Nuclear Information System (INIS)

    Piping Supriatna; Nurhanan; Riswan DJ; Heru K, B.; Edi Karyanta

    2003-01-01

    Nuclear Power Plan Operation Safety needs serious handling on temperature measurement and control. In this report has been done manufacturing Temperature Control System for Chromel-Alumel Thermocouple, accordance to material, equipment and human resource ability in the laboratory. Basic component for the Temperature Control System is LM-741 type of Operation Amplifier, which is functionalized as summer for voltage comparator. Function test for this Control System shown its ability for damping on temperature reference. The Temperature Control System will be implemented on PCB Processing Machine. (author)

  20. A method to eliminate the effect of radiation on thermocouple performance

    International Nuclear Information System (INIS)

    Ali, Fawaz; Lu Lixuan

    2007-01-01

    In-core temperature measurements are pivotal in maintaining nuclear reactors in a safe state of operation. Thermocouples serve as the liaison in ensuring this safe state. The realization of the thermocouple's full potential is hindered by the fact that thermocouples cannot be situated in areas with high radiation fields. Radiation has the potential of generating voltages in the thermocouple wires, hence producing an error in the temperature transmitter output. In this paper, a mathematical model is developed to quantify the effect that radiation from the Canada Deuterium Uranium (CANDU) Nuclear Power Plants (NPPs) has on the thermocouple temperature reading. Subsequently, a method to offset the effect of radiation on the thermocouple is proposed. Simulation is performed to verify the effectiveness of the proposed system

  1. SAFETY AND TOLERABILITY OF ANTIEPILEPTIC DRUGS AT WOMEN WITH EPILEPSY (DATA OF SVT. LUKA’S INSTITUTE OF CHILD NEUROLOGY AND EPILEPSY

    Directory of Open Access Journals (Sweden)

    K. Yu. Мukhin

    2015-01-01

    Full Text Available Women with epilepsy are referred to the special risk group due to the development of side effects of antiepileptic drugs (АED. Women’s neuroendocrinal disorders can be caused by the disease itself-epilepsy, as well as by the undertaken therapy. We have carried out a retrospective research in order to assess the safety and the tolerance of different AED at young girls and women of reproductive age. Was analyzed the data base of patients of Svt. Luka’s Institute of Child Neurology and Epilepsy, comprising all patients, who have been monitored in the period between 2000 and 2014 inclusive at the age between 15–40 years (n = 301. The research included patients, with different diagnosed forms of focal or generalized epilepsy, who were taking AED both during mono and polytherapy. Were analyzed all cases of neuroendocrinal, especially reproductive disorders, including the considerable gain of weight, menstrual disorder, sterility at AED background. Also was analyzed the result of all registered pregnancies at women with epilepsy (at the background of the antiepileptic therapy, as well as without treatment during pregnancy. The retrospective data analysis has revealed 51 сase (17 % in the group under review of expressed neuroendocrinal, reproductive and cosmetic side effects (including the menstrual disorder: dysmenorrhea, opsomenorrhea, amenorrhea, anovulatory cycles, sterility, unfavorable pregnancy outcomes, as well as cosmetic endocrinal side effects: obesity, hirsutism, hair loss. Most patients have got such combined side effects. Our research results show, that in most cases the pregnancy at women with epilepsy ends by birth of a healthy child, the pregnancy outcome depends on many factors, it also differs according to applied AED. Valproic acid drugs show the highest teratogenic risk. Also at the back ground of the therapy with valproic acid have been registered most cases of neuroendocrinal reproductive diseases at women

  2. 78 FR 56174 - In-Core Thermocouples at Different Elevations and Radial Positions in Reactor Core

    Science.gov (United States)

    2013-09-12

    ... 52 [Docket No. PRM-50-105; NRC-2012-0056] In-Core Thermocouples at Different Elevations and Radial Positions in Reactor Core AGENCY: Nuclear Regulatory Commission. ACTION: Petition for rulemaking; denial...-core thermocouples at different elevations and radial positions throughout the reactor core to enable...

  3. 77 FR 30435 - In-core Thermocouples at Different Elevations and Radial Positions in Reactor Core

    Science.gov (United States)

    2012-05-23

    ... NUCLEAR REGULATORY COMMISSION 10 CFR Part 50 [Docket No. PRM-50-105; NRC-2012-0056] In-core Thermocouples at Different Elevations and Radial Positions in Reactor Core AGENCY: Nuclear Regulatory Commission... of operating licenses for nuclear power plants (``NPP'') to operate NPPs with in-core thermocouples...

  4. Structural evaluation of thermocouple probes for 241-AZ-101 waste tank

    International Nuclear Information System (INIS)

    Kanjilal, S.K.

    1994-01-01

    This document reports on the structural analysis of the thermocouple probe to be installed in 241-AZ-101 waste tank. The thermocouple probe is analyzed for normal pump mixing operation and potential earthquake induced loads required by the Hanford Site Design Criteria SDC-4.1

  5. Structural evaluation of thermocouple probes for 241-AZ-101 waste tank

    Energy Technology Data Exchange (ETDEWEB)

    Kanjilal, S.K.

    1994-12-06

    This document reports on the structural analysis of the thermocouple probe to be installed in 241-AZ-101 waste tank. The thermocouple probe is analyzed for normal pump mixing operation and potential earthquake induced loads required by the Hanford Site Design Criteria SDC-4.1.

  6. Detection of thermocouple malfunction in the Beacon system

    International Nuclear Information System (INIS)

    Morita, T.; Heibel, M.D.; Congedo, T.V.

    1992-01-01

    The BEACON system uses Core Exit Thermocouples (T/C) extensively for continuous radial power distribution monitoring. The T/C's are used to adjust the reference power distribution generated by the BEACON system to match the current radial power distribution. T/C reliability, repeatability, and relative accuracy have been very satisfactory. However, it is very important to detect any T/C malfunctions during operation, since a T/C signal change caused by an undetected malfunction can lead to serious errors in the radial power distribution developed by BEACON. A simple procedure has been developed which is capable of discriminating between changes in T/C signals caused by actual changes in reactor conditions and signal changes caused by T/C malfunctions

  7. Design and research of seal structure for thermocouple column assembly

    International Nuclear Information System (INIS)

    Rao Qiqi; Li Na; Zhao Wei; Ma Zhigang

    2015-01-01

    The new seal structure was designed to satisfy the function of thermocouple column assembly and the reactor structure. This seal structure uses the packing graphite ring and adopts the self-sealing principle. Cone angle is brought to the seal face of seal structure which is conveniently to assembly and disassembly. After the sealing principle analysis and stress calculation of graphite ring which adopt the cone angle, the cone angle increases the radial force of seal structure and improves the seal effect. The stress analysis result shows the seal structure strength satisfies the regulation requirement. The cold and hot function test results shows the sealing effect is good, and the design requirement is satisfied. (authors)

  8. LOFT ECC Pitot Tube and Thermocouple Rake Penetration thermal analysis

    International Nuclear Information System (INIS)

    Tolan, B.J.

    1977-01-01

    A thermal analysis of the LOFT ECC Pitot Tube and Thermocouple Rake Penetration was performed using COUPLE, a two-dimensional finite element computer code. Four transients which conservatively cover all transients the rake will be exposed to were included in this analysis in order to comply with the ASME Code Section III requirements. The transients conservatively cover hot and cold leg operation, and nuclear and nonnuclear operation. The four transients include the LOCE with ECC injection transient, the single control rod drop transient, the scram transient, and the heatup with 0 to 100% load change transient. Temperature distributions in the rake were obtained for each of the four transients and several plots of node temperatures vs. time are given

  9. Lifetime improvement of sheathed thermocouples for use in high-temperature and thermal transient operations

    International Nuclear Information System (INIS)

    McCulloch, R.W.; Clift, J.H.

    1982-01-01

    Premature failure of small-diameter, magnesium-oxide-insulated sheathed thermocouples occurred when they were placed within nuclear fuel rod simulators (FRSs) to measure high temperatures and to follow severe thermal transients encountered during simulation of nuclear reactor accidents in Oak Ridge National Laboratory (ORNL) thermal-hydraulic test facilities. Investigation of thermally cycled thermocouples yielded three criteria for improvement of thermocouple lifetime: (1) reduction of oxygen impurities prior to and during their fabrication, (2) refinement of thermoelement grain size during their fabrication, and (3) elimination of prestrain prior to use above their recrystallization temperature. The first and third criteria were satisfied by improved techniques of thermocouple assembly and by a recovery anneal prior to thermocouple use

  10. Blind system identification of two-thermocouple sensor based on cross-relation method

    Science.gov (United States)

    Li, Yanfeng; Zhang, Zhijie; Hao, Xiaojian

    2018-03-01

    In dynamic temperature measurement, the dynamic characteristics of the sensor affect the accuracy of the measurement results. Thermocouples are widely used for temperature measurement in harsh conditions due to their low cost, robustness, and reliability, but because of the presence of the thermal inertia, there is a dynamic error in the dynamic temperature measurement. In order to eliminate the dynamic error, two-thermocouple sensor was used to measure dynamic gas temperature in constant velocity flow environments in this paper. Blind system identification of two-thermocouple sensor based on a cross-relation method was carried out. Particle swarm optimization algorithm was used to estimate time constants of two thermocouples and compared with the grid based search method. The method was validated on the experimental equipment built by using high temperature furnace, and the input dynamic temperature was reconstructed by using the output data of the thermocouple with small time constant.

  11. An experimental study of the effect of external thermocouples on rewetting during reflood

    International Nuclear Information System (INIS)

    Shires, G.L.; Butcher, A.A.; Carpenter, B.G.; McCune, D.S.; Pearson, K.G.

    1980-04-01

    The validation of computer codes used for PWR safety assessment often depends upon experiments carried out with either real fuel pins or electrically heated fuel pin simulators. In some cases, and this applies particularly to in-pile tests, temperatures are measured by means of sheathed thermocouples attached externally to the pins and this raises the question of the possible effect of such thermocouples on the two phase hydraulics and heat transfer which are being studied. This paper describes the experiments which subjected two realistic fuel pin simulators, one with and one without external thermocouples, to identical bottom flooding conditions. They demonstrate very clearly that external thermocouples act as preferential rewetting sites and thereby increase the rate of propagation of the quench front. In the view of the authors of this paper the facts described raise serious doubts about the validity of rewetting data obtained from experiments employing external thermocouples. (U.K.)

  12. A Modified Design of a Thermocouple Based Digital Temperature Indicator with Opto-Isolation

    Directory of Open Access Journals (Sweden)

    S. C. BERA

    2008-01-01

    Full Text Available In the conventional thermocouple based digital temperature indicator the millivolt signal obtained from a thermocouple is first amplified and then converted into a digital signal by using analog-to-digital converter (ADC. This digital signal is then indicated as digital display of temperature using digital counter circuit or microprocessor/microcontroller based circuitry. In the present paper a modified AD conversion technique along with opto-isolation is used to indicate digitally the temperature without using any conventional analog-to-digital converter. The theory and design of the measuring technique are described in the paper. The non-linearity of thermocouple is eliminated by using look-up table within software program. The performance of the circuit has been experimentally tested by using mV input signal instead of a thermocouple as well as using a K-type thermocouple. The experimental results are reported in the paper.

  13. The transient response for different types of erodable surface thermocouples using finite element analysis

    Directory of Open Access Journals (Sweden)

    Mohammed Hussein

    2007-01-01

    Full Text Available The transient response of erodable surface thermocouples has been numerically assessed by using a two dimensional finite element analysis. Four types of base metal erodable surface thermocouples have been examined in this study, included type-K (alumel-chromel, type-E (chromel-constantan, type-T (copper-constantan, and type-J (iron-constantan with 50 mm thick- ness for each. The practical importance of these types of thermocouples is to be used in internal combustion engine studies and aerodynamics experiments. The step heat flux was applied at the surface of the thermocouple model. The heat flux from the measurements of the surface temperature can be commonly identified by assuming that the heat transfer within these devices is one-dimensional. The surface temperature histories at different positions along the thermocouple are presented. The normalized surface temperature histories at the center of the thermocouple for different types at different response time are also depicted. The thermocouple response to different heat flux variations were considered by using a square heat flux with 2 ms width, a sinusoidal surface heat flux variation width 10 ms period and repeated heat flux variation with 2 ms width. The present results demonstrate that the two dimensional transient heat conduction effects have a significant influence on the surface temperature history measurements made with these devices. It was observed that the surface temperature history and the transient response for thermocouple type-E are higher than that for other types due to the thermal properties of this thermocouple. It was concluded that the thermal properties of the surrounding material do have an impact, but the properties of the thermocouple and the insulation materials also make an important contribution to the net response.

  14. Temperature measurement error due to the effects of time varying magnetic fields on thermocouples with ferromagnetic thermoelements

    International Nuclear Information System (INIS)

    McDonald, D.W.

    1977-01-01

    Thermocouples with ferromagnetic thermoelements (iron, Alumel, Nisil) are used extensively in industry. We have observed the generation of voltage spikes within ferromagnetic wires when the wires are placed in an alternating magnetic field. This effect has implications for thermocouple thermometry, where it was first observed. For example, the voltage generated by this phenomenon will contaminate the thermocouple thermal emf, resulting in temperature measurement error

  15. Thin film platinum–palladium thermocouples for gas turbine engine applications

    Energy Technology Data Exchange (ETDEWEB)

    Tougas, Ian M.; Gregory, Otto J., E-mail: gregory@egr.uri.edu

    2013-07-31

    Thin film platinum:palladium thermocouples were fabricated on alumina and mullite surfaces using radio frequency sputtering and characterized after high temperature exposure to oxidizing environments. The thermoelectric output, hysteresis, and drift of these sensors were measured at temperatures up to 1100 °C. Auger electron spectroscopy was used to follow the extent of oxidation in each thermocouple leg and interdiffusion at the metallurgical junction. Minimal oxidation of the platinum and palladium thermoelements was observed after high temperature exposure, but considerable dewetting and faceting of the films were observed in scanning electron microscopy. An Arrhenius temperature dependence on the drift rate was observed and later attributed to microstructural changes during thermal cycling. The thin film thermocouples, however, did exhibit excellent stability at 1000 °C with drift rates comparable to commercial type-K wire thermocouples. Based on these results, platinum:palladium thin film thermocouples have considerable potential for use in the hot sections of gas turbine engines. - Highlights: • Stable thin film platinum:palladium thermocouples for gas turbine engines • Little oxidation but significant microstructural changes from thermal cycling • Minimal hysteresis during repeated thermal cycling • Drift comparable to commercial wire thermocouples.

  16. Contact Thermocouple Methodology and Evaluation for Temperature Measurement in the Laboratory

    Science.gov (United States)

    Brewer, Ethan J.; Pawlik, Ralph J.; Krause, David L.

    2013-01-01

    Laboratory testing of advanced aerospace components very often requires highly accurate temperature measurement and control devices, as well as methods to precisely analyze and predict the performance of such components. Analysis of test articles depends on accurate measurements of temperature across the specimen. Where possible, this task is accomplished using many thermocouples welded directly to the test specimen, which can produce results with great precision. However, it is known that thermocouple spot welds can initiate deleterious cracks in some materials, prohibiting the use of welded thermocouples. Such is the case for the nickel-based superalloy MarM-247, which is used in the high temperature, high pressure heater heads for the Advanced Stirling Converter component of the Advanced Stirling Radioisotope Generator space power system. To overcome this limitation, a method was developed that uses small diameter contact thermocouples to measure the temperature of heater head test articles with the same level of accuracy as welded thermocouples. This paper includes a brief introduction and a background describing the circumstances that compelled the development of the contact thermocouple measurement method. Next, the paper describes studies performed on contact thermocouple readings to determine the accuracy of results. It continues on to describe in detail the developed measurement method and the evaluation of results produced. A further study that evaluates the performance of different measurement output devices is also described. Finally, a brief conclusion and summary of results is provided.

  17. Thermoelectric properties of currently available Au/Pt thermocouples related to the valid reference function

    Directory of Open Access Journals (Sweden)

    Edler F.

    2015-01-01

    Full Text Available Au/Pt thermocouples are considered to be an alternative to High Temperature Standard Platinum Resistance Thermometers (HTSPRTs for realizing temperatures according to the International Temperature Scale of 1990 (ITS-90 in the temperature range between aluminium (660.323 °C and silver (961.78 °C. The original aim of this work was to develop and to validate a new reference function for Au/Pt thermocouples which reflects the properties of presently commercially available Au and Pt wires. The thermoelectric properties of 16 Au/Pt thermocouples constructed at different National Metrological Institutes by using wires from different suppliers and 4 commercially available Au/Pt thermocouples were investigated. Most of them exhibit significant deviations from the current reference function of Au/Pt thermocouples caused by the poor performance of the Au-wires available. Thermoelectric homogeneity was investigated by measuring immersion profiles during freezes at the freezing point of silver and in liquid baths. The thermoelectric inhomogeneities were found to be one order of magnitude larger than those of Au/Pt thermocouples of the Standard Reference Material® (SRM® 1749. The improvement of the annealing procedure of the gold wires is a key process to achieve thermoelectric homogeneities in the order of only about (2–3 mK, sufficient to replace the impracticable HTSPRTs as interpolation instruments of the ITS-90. Comparison measurements of some of the Au/Pt thermocouples against a HTSPRT and an absolutely calibrated radiation thermometer were performed and exhibit agreements within the expanded measurement uncertainties. It has been found that the current reference function of Au/Pt thermocouples reflects adequately the thermoelectric properties of currently available Au/Pt thermocouples.

  18. Studies of Behavior Melting Temperature Characteristics for Multi Thermocouple In-Core Instrument Assembly

    International Nuclear Information System (INIS)

    Shin, Donghyup; Chae, Myoungeun; Kim, Sungjin; Lee, Kyulim

    2015-01-01

    Bottom-up type in-core instruments (ICIs) are used for the pressurized water reactors of OPR-1000, APR- 1400 in order to measure neutron flux and temperature in the reactor. It is a well-known technique and a proven design using years in the nuclear field. ICI consists of one pair of K-type thermocouple, five self-powered neutron detectors (SPNDs) and one back ground detector. K-type thermocouple's purpose is to measure the core exit temperature (CET) in the reactor. The CET is a very important factor for operating nuclear power plants and it is 327 .deg. C when generally operating the reactor in the nuclear power plant(NPP) in case of OPR- 1000. If the CET will exceed 650 .deg. C, Operators in the main control room should be considered to be an accident situation in accordance with a severe accident management guidance(SAMG). The Multi Thermocouple ICI is a new designed ICI assuming severe accident conditions. It consists of four more thermocouples than the existing design, so it has five Ktype thermocouples besides the thermocouple measuring CET is located in the same elevation as the ICI. Each thermocouple is able to be located in the desired location as required. The Multi Thermocouple ICI helps to measure the temperature distribution of the entire reactor. In addition, it will measure certain point of melted core because of the in-vessel debris of nuclear fuel when an accident occurs more seriously. In this paper, to simulate a circumstance such as a nuclear reactor severe accident was examined. In this study, the K-type thermocouples of Multi Thermocouple ICI was confirmed experimentally to be able to measure up to 1370 .deg. C before the thermocouples have been melted. And after the thermocouples were melted by debris, it was able to be monitored that the signal of EMF directed the infinite value of voltage. Therefore through the results of the test, it can be assumed that if any EMF data among the Multi Thermocouple ICI will direct the infinite value

  19. Studies of Behavior Melting Temperature Characteristics for Multi Thermocouple In-Core Instrument Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Donghyup; Chae, Myoungeun; Kim, Sungjin; Lee, Kyulim [Woojin inc, Hwasung (Korea, Republic of)

    2015-05-15

    Bottom-up type in-core instruments (ICIs) are used for the pressurized water reactors of OPR-1000, APR- 1400 in order to measure neutron flux and temperature in the reactor. It is a well-known technique and a proven design using years in the nuclear field. ICI consists of one pair of K-type thermocouple, five self-powered neutron detectors (SPNDs) and one back ground detector. K-type thermocouple's purpose is to measure the core exit temperature (CET) in the reactor. The CET is a very important factor for operating nuclear power plants and it is 327 .deg. C when generally operating the reactor in the nuclear power plant(NPP) in case of OPR- 1000. If the CET will exceed 650 .deg. C, Operators in the main control room should be considered to be an accident situation in accordance with a severe accident management guidance(SAMG). The Multi Thermocouple ICI is a new designed ICI assuming severe accident conditions. It consists of four more thermocouples than the existing design, so it has five Ktype thermocouples besides the thermocouple measuring CET is located in the same elevation as the ICI. Each thermocouple is able to be located in the desired location as required. The Multi Thermocouple ICI helps to measure the temperature distribution of the entire reactor. In addition, it will measure certain point of melted core because of the in-vessel debris of nuclear fuel when an accident occurs more seriously. In this paper, to simulate a circumstance such as a nuclear reactor severe accident was examined. In this study, the K-type thermocouples of Multi Thermocouple ICI was confirmed experimentally to be able to measure up to 1370 .deg. C before the thermocouples have been melted. And after the thermocouples were melted by debris, it was able to be monitored that the signal of EMF directed the infinite value of voltage. Therefore through the results of the test, it can be assumed that if any EMF data among the Multi Thermocouple ICI will direct the infinite value

  20. Flow measurements using noise signals of axially displaced thermocouples

    Energy Technology Data Exchange (ETDEWEB)

    Kozma, R.; Hoogenboom, J.E. (Interuniversitair Reactor Inst., Delft (Netherlands))

    1990-01-01

    Determination of the flow rate of the coolant in the cooling channels of nuclear reactors is an important aspect of core monitoring. It is usually impossible to measure the flow by flowmeters in the individual channels due to the lack of space and safety reasons. An alternative method is based on the analysis of noise signals of the available in-core detectors. In such a noise method, a transit time which characterises the propagation of thermohydraulic fluctuations (density or temperature fluctuations) in the coolant is determined from the correlation between the noise signals of axially displaced detectors. In this paper, the results of flow measurements using axially displaced thermocouples in the channel wall will be presented. The experiments have been performed in a simulated MRT-type fuel assembly located in the research reactor HOR of the Interfaculty Reactor Institute, Delft. It was found that the velocities obtained via temperature noise correlation methods are significantly larger than the area-averaged velocity in the single-phase coolant flow. Model calculations show that the observed phenomenon can be explained by effects due to the radial velocity distribution in the channel. (author).

  1. Field installed brazed thermocouple feedthroughs for high vacuum experiments

    International Nuclear Information System (INIS)

    Anderson, P.; Messick, C.

    1983-01-01

    In order to reduce the occurrence of vacuum leaks and to increase the availability of the DIII vacuum vessel for experimental operation, effort was applied to developing a vacuum-tight brazed feedthrough system for sheathed thermocouples, stainless steel sheathed conductor cables and tubes for cooling fluids. This brazed technique is a replacement for elastomer ''O'' ring sealed feedthroughs that have proven vulnerable to leaks caused by thermal cycling, etc. To date, about 200 feedthroughs have been used. Up to 91 were grouped on a single conflat flange mounted in a bulkhead connector configuration which facilitates installation and removal. Investigation was required to select a suitable braze alloy, flux and installation procedure. Braze alloy selection was challenging since the alloy was required to have: 1) Melting temperature in excess of the 250 0 C (482 0 F) bakeout temperature. 2) No high vapor pressure elements. 3) Good wetting properties when used in air with acceptable flux. 4) Good wettability to 300 series stainless steel and inconel

  2. Status self-validation of a multifunctional sensor using a multivariate relevance vector machine and predictive filters

    International Nuclear Information System (INIS)

    Shen, Zhengguang; Wang, Qi

    2013-01-01

    A novel strategy by using a multivariable relevance vector machine coupled with predictive filters for status self-validation of a multifunctional sensor is proposed. The working principle and online updating algorithm of predictive filters are emphasized for multiple fault detection, isolation and recovery (FDIR), and the incorrect sensor measurements are validated online. The multivariable relevance vector machine is then employed for the signal reconstruction of the multifunctional sensor to generate the final validated measurement values (VMV) of multiple measured components, in which its advantages of sparse models and multivariable simultaneous outputs are fully used. With all likely uncertainty sources of the multifunctional self-validating sensor taken into account, the uncertainty propagation model is deduced in detail to evaluate the online validated uncertainty (VU) under a fault-free situation while a qualitative uncertainty component is appended to indicate the accuracy changes of VMV under different types of fault. A real experimental system of a multifunctional self-validating sensor is designed to verify the performance of the proposed strategy. From the real-time capacity and fault recovery accuracy of FDIR, and runtime of signal reconstruction under small samples, a performance comparison among different methods is made. Results demonstrate that the proposed scheme provides a better solution to the status self-validation of a multifunctional self-validating sensor under both normal and abnormal situations. (paper)

  3. Temperature measurement: Development work on noise thermometry and improvement of conventional thermocouples for applications in nuclear process heat (PNP)

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Oehmen, J.; Barbonus, P.; Hans, R.

    1982-06-01

    The behaviour was studied of NiCr-Ni sheathed thermocouples (sheath Inconel 600 or Incoloy 800, insulation MgO) in a helium and carbon atmosphere at temperatures of 950-1150 deg. C. All the thermocouples used retained their functional performance. The insulation resistance tended towards a limit value which is dependent on the temperature and quality of the thermocouple. Temperature measurements were loaded with great uncertainty in the temperature range of 950-1150 deg. C. Recalibrations at the temperature of 950 deg. C showed errors of up to 6%. Measuring sensors were developed which consist of a sheathed double thermocouple with a noise resistor positioned between the two hot junctions. Using the noise thermometer it is possible to recalibrate the thermocouple at any time in situ. A helium system with a high temperature experimental area was developed to test the thermocouples and the combined thermocouple-noise thermometer sensors under true experimental conditions

  4. Thought confidence as a determinant of persuasion: the self-validation hypothesis.

    Science.gov (United States)

    Petty, Richard E; Briñol, Pablo; Tormala, Zakary L

    2002-05-01

    Previous research in the domain of attitude change has described 2 primary dimensions of thinking that impact persuasion processes and outcomes: the extent (amount) of thinking and the direction (valence) of issue-relevant thought. The authors examined the possibility that another, more meta-cognitive aspect of thinking is also important-the degree of confidence people have in their own thoughts. Four studies test the notion that thought confidence affects the extent of persuasion. When positive thoughts dominate in response to a message, increasing confidence in those thoughts increases persuasion, but when negative thoughts dominate, increasing confidence decreases persuasion. In addition, using self-reported and manipulated thought confidence in separate studies, the authors provide evidence that the magnitude of the attitude-thought relationship depends on the confidence people have in their thoughts. Finally, the authors also show that these self-validation effects are most likely in situations that foster high amounts of information processing activity.

  5. Evaluating the message or the messenger? Implications for self-validation in persuasion.

    Science.gov (United States)

    Clark, Jason K; Wegener, Duane T; Sawicki, Vanessa; Petty, Richard E; Briñol, Pablo

    2013-12-01

    Characteristics of persuasive message sources have been extensively studied. However, little attention has been paid to situations when people are motivated to form an evaluation of the communicator rather than the communicated issue. We postulated that these different foci can affect how a source validates message-related cognitions. Participants focused on the source (Studies 1 and 2) or the issue (Study 2) while reading weak or strong message arguments. Later, the communicator was described as low or high in credibility. When focused on the source, highly motivated participants were more confident and their attitudes were more reflective of thoughts when argument quality matched (e.g., weak arguments-low credibility) rather than mismatched (e.g., weak arguments-high credibility) source credibility. Conversely, when participants were focused on the issue, self-validation was greater when credibility was high rather than low-regardless of argument quality. Implications of these findings for the study and practice of persuasion are discussed.

  6. Thermocouples calibration and analysis of the influence of the length of the sensor coating

    International Nuclear Information System (INIS)

    Noriega, M; Ramírez, R; López, R; Vaca, M; Morales, J; Terres, H; Lizardi, A; Chávez, S

    2015-01-01

    This paper presents the design and construction of a lab prototype, with a much lower cost compared to the ones commercially sold, enabling the manufacture of thermocouples which are then calibrated to verify their functionality and acceptance. We also analyze the influence of the external insulation over the wires, to determine whether it influences temperature measurement. The tested lengths ranged from 0.00 m up to 0.030 m. The thermocouple was compared against the behavior of a thermocouple of the same type that was purchased with a commercial supplier. The obtained measurement showed less than 1 °C difference in some points. This makes the built thermocouple reliable, since the standard allows a difference of up to 2.2 °C

  7. The use of thermocouples which transmute during service in nuclear reactors

    International Nuclear Information System (INIS)

    Martin, R.E.

    1980-06-01

    Some current nuclear fuel experiments at CRNL require the use of thermocouples to measure temperatures of up to 2200 0 C under reactor operating conditions. A literature search has shown that transient electrical effects and transmutation of the thermocouple alloys can cause temperature measurement errors of up to +-1% and +-30%, respectively. However, the error due to transient electrical effects can be corrected by making temperature measurements immediately following reactor shutdown. Furthermore it has been shown that transmutation effects can be corrected for by calibrating the high temperature tungsten-rhenium thermocouples against a chromel-alumel thermocouple in a cooler part of the experiment. The use of these techniques is expected to reduce temperature measurement errors to +-2% in the best case. (auth)

  8. Thermocouple module halt failure acceptance test procedure for Tank 241-SY-101 DACS-1

    International Nuclear Information System (INIS)

    Ermi, A.M.

    1997-01-01

    The readiness of the Tank 241-SY-101 Data Acquisition and Control System (DACS-1) to provide monitoring and alarms for a halt failure of any thermocouple module will be tested during the performance of this procedure. Updated DACS-1 ''1/0 MODULE HEALTH STATUS'', ''MININ1'', and ''MININ2'' screens, which now provide indication of thermocouple module failure, will also be tested as part of this procedure

  9. Thermocouple calibration facility for 2900 deg C high temperature and its applications

    International Nuclear Information System (INIS)

    Chen Daolong

    1991-01-01

    The construction and the performance characteristic of a 2900 deg C high temperature thermocouple calibration facility are described. The calibration error analysis is made. The test results of the calibration characteristics of high temperature thermocouples Mo/Nb, W-3Re/W-25Re, and W-1Mo/W-25Mo are given. The test result of temperature dependent resistivity of BeO made by this facility is given

  10. Attachment of Free Filament Thermocouples for Temperature Measurements on CMC

    Science.gov (United States)

    Lei, Jih-Fen; Cuy, Michael D.; Wnuk, Stephen P.

    1997-01-01

    Ceramic Matrix Composites (CMC) are being developed for use as enabling materials for advanced aeropropulsion engine and high speed civil transport applications. The characterization and testing of these advanced materials in hostile, high-temperature environments require accurate measurement of the material temperatures. Commonly used wire Thermo-Couples (TC) can not be attached to this ceramic based material via conventional spot-welding techniques. Attachment of wire TC's with commercially available ceramic cements fail to provide sufficient adhesion at high temperatures. While advanced thin film TC technology provides minimally intrusive surface temperature measurement and has good adhesion on the CMC, its fabrication requires sophisticated and expensive facilities and is very time consuming. In addition, the durability of lead wire attachments to both thin film TC's and the substrate materials requires further improvement. This paper presents a newly developed attachment technique for installation of free filament wire TC's with a unique convoluted design on ceramic based materials such as CMC's. Three CMC's (SiC/SiC CMC and alumina/alumina CMC) instrumented with type IC, R or S wire TC's were tested in a Mach 0.3 burner rig. The CMC temperatures measured from these wire TC's were compared to that from the facility pyrometer and thin film TC's. There was no sign of TC delamination even after several hours exposure to 1200 C. The test results proved that this new technique can successfully attach wire TC's on CMC's and provide temperature data in hostile environments. The sensor fabrication process is less expensive and requires very little time compared to that of the thin film TC's. The same installation technique/process can also be applied to attach lead wires for thin film sensor systems.

  11. Degradation by radiation of the response of a thermocouple of a fuel element

    International Nuclear Information System (INIS)

    Rodriguez V, A.

    1994-01-01

    In the TRIGA Mark III Reactor of the National Institute of Nuclear Research, is necessary to use an instrumented fuel element for measurement the fuel temperature during pulses of power. This fuel element is exposed to daily temperature gradient of order to 390 Centigrade degrees in normal condition of reactor operation at 1 MW. The experience which this instrumented fuel elements is that useful life of the thermocouples is less then the fuel, because they show important changes in their chemistry composition and electrical specifications, until the point they don't give any response. So is necessary to know the factors that influenced in the shortening of the thermocouples life. The change in composition affects the thermocouple calibration depends on where the changes take place relative to the temperature gradient. The change will be dependent on the neutron flux and so the value of the neutron flux may be used as a measure or the composition change. If there is no neutron flux within the temperature gradient, there will be no composition change, and so the thermocouple calibration will no change. If the neutron flux varies within the region in which a temperature gradients exists, the composition of the thermocouple will vary and the calibration will change. But the maximum change in calibration will occur if the neutron flux is high and constant within the region of the temperature gradient. In this case, a composition change takes place which is uniform throughout the gradient and so the emf output can be expected to change. In this reactor, the thermocouples are in the second case. Then, the relative position of the thermal and neutron flux gradients are the most important factor that explain the composition change after or 2,500 times of exposing the thermocouples to the temperature gradients of order to 390 Centigrade degrees. (Author)

  12. The effects of majority versus minority source status on persuasion: a self-validation analysis.

    Science.gov (United States)

    Horcajo, Javier; Petty, Richard E; Briñol, Pablo

    2010-09-01

    The present research proposes that sources in the numerical majority (vs. minority) can affect persuasion by influencing the confidence with which people hold their thoughts in response to the persuasive message. Participants received a persuasive message composed of either strong or weak arguments that was presented by a majority or a minority source. Consistent with the self-validation hypothesis, we predicted and found that the majority (vs. minority) status of the source increased the confidence with which recipients held their thoughts. As a consequence, majority (vs. minority) sources increased argument quality effects in persuasion when source status information followed message processing (Experiment 1). In contrast, when the information regarding source status preceded (rather than followed) the persuasive message, it validated the perception of the position advocated, reducing message processing. As a consequence of having more confidence in the position advocated before receiving the message, majority (vs. minority) sources reduced argument quality effects in persuasion (Experiment 2). Finally, Experiment 3 isolated the timing of the source status manipulation, revealing that sources in the numerical majority (vs. minority) can increase or decrease persuasion to strong arguments depending on whether source status is introduced before or after processing the message. (PsycINFO Database Record (c) 2010 APA, all rights reserved).

  13. A Novel Health Evaluation Strategy for Multifunctional Self-Validating Sensors

    Directory of Open Access Journals (Sweden)

    Zhengguang Shen

    2013-01-01

    Full Text Available The performance evaluation of sensors is very important in actual application. In this paper, a theory based on multi-variable information fusion is studied to evaluate the health level of multifunctional sensors. A novel conception of health reliability degree (HRD is defined to indicate a quantitative health level, which is different from traditional so-called qualitative fault diagnosis. To evaluate the health condition from both local and global perspectives, the HRD of a single sensitive component at multiple time points and the overall multifunctional sensor at a single time point are defined, respectively. The HRD methodology is emphasized by using multi-variable data fusion technology coupled with a grey comprehensive evaluation method. In this method, to acquire the distinct importance of each sensitive unit and the sensitivity of different time points, the information entropy and analytic hierarchy process method are used, respectively. In order to verify the feasibility of the proposed strategy, a health evaluating experimental system for multifunctional self-validating sensors was designed. The five different health level situations have been discussed. Successful results show that the proposed method is feasible, the HRD could be used to quantitatively indicate the health level and it does have a fast response to the performance changes of multifunctional sensors.

  14. Development of a micro-thermal flow sensor with thin-film thermocouples

    Science.gov (United States)

    Kim, Tae Hoon; Kim, Sung Jin

    2006-11-01

    A micro-thermal flow sensor is developed using thin-film thermocouples as temperature sensors. A micro-thermal flow sensor consists of a heater and thin-film thermocouples which are deposited on a quartz wafer using stainless steel masks. Thin-film thermocouples are made of standard K-type thermocouple materials. The mass flow rate is measured by detecting the temperature difference of the thin-film thermocouples located in the upstream and downstream sections relative to a heater. The performance of the micro-thermal flow sensor is experimentally evaluated. In addition, a numerical model is presented and verified by experimental results. The effects of mass flow rate, input power, and position of temperature sensors on the performance of the micro-thermal flow sensor are experimentally investigated. At low values, the mass flow rate varies linearly with the temperature difference. The linearity of the micro-thermal flow sensor is shown to be independent of the input power. Finally, the position of the temperature sensors is shown to affect both the sensitivity and the linearity of the micro-thermal flow sensor.

  15. Cladding temperature measurement by thermocouples at preirradiated LWR fuel rod samples

    International Nuclear Information System (INIS)

    Leiling, W.

    1981-12-01

    This report describes the technique to measure cladding temperatures of test fuel rod samples, applied during the in-pile tests on fuel rod failure in the steam loop of the FR2 reactor. NiCr/Ni thermocouples with stainless steel and Inconel sheaths, respectively,of 1 mm diameter were resistance spot weld to the outside of the fuel rod cladding. For the pre-irradiated test specimens, welding had to be done under hot-cell conditions, i.e. under remote handling. In order to prevent the formation of eutectics between zirconium and the chemical elements of the thermocouple sheath at elevated temperatures, the thermocouples were covered with a platinum jacket of 1.4 mm outside diameter swaged onto the sheath in the area of the measuring junction. This thermocouple design has worked satisfactorily in the in-pile experiments performed in a steam atmosphere. Even in the heatup phase, in which cladding temperatures up to 1050 0 C were reached, only very few failures occured. This good performance is to a great part due to a careful control and a thorough inspection of the thermocouples. (orig.) [de

  16. Establishment of the Co-C Eutectic Fixed-Point Cell for Thermocouple Calibrations at NIMT

    Science.gov (United States)

    Ongrai, O.; Elliott, C. J.

    2017-08-01

    In 2015, NIMT first established a Co-C eutectic temperature reference (fixed-point) cell measurement capability for thermocouple calibration to support the requirements of Thailand's heavy industries and secondary laboratories. The Co-C eutectic fixed-point cell is a facility transferred from NPL, where the design was developed through European and UK national measurement system projects. In this paper, we describe the establishment of a Co-C eutectic fixed-point cell for thermocouple calibration at NIMT. This paper demonstrates achievement of the required furnace uniformity, the Co-C plateau realization and the comparison data between NIMT and NPL Co-C cells by using the same standard Pt/Pd thermocouple, demonstrating traceability. The NIMT measurement capability for noble metal type thermocouples at the new Co-C eutectic fixed point (1324.06°C) is estimated to be within ± 0.60 K (k=2). This meets the needs of Thailand's high-temperature thermocouple users—for which previously there has been no traceable calibration facility.

  17. Evaluation of thermocouple fin effect in cladding surface temperature measurement during film boiling

    International Nuclear Information System (INIS)

    Tsuruta, Takaharu; Fujishiro, Toshio

    1984-01-01

    Thermocouple fin effect on surface temperature measurement of a fuel rod has been studied at elevated wall temperatures under film boiling condition in a reactivity initiated accident (RIA) situation. This paper presents an analytical equation to evaluate temperature drops caused by the thermocouple wires attached to cladding surface. The equation yielded the local temperature drop at measuring point depending on thermocouple diameter, cladding temperature, coolant flow condition and vapor film thickness. The temperature drops by the evaluating equation were shown in cases of free and forced convection conditions. The analytical results were compared with the measured data for various thermocouple sizes, and also with the estimated maximum cladding temperature based on the oxidation layer thickness in the cladding outer surface. It was concluded that the temperature drops at above 1,000 0 C in cladding temperature were around 120 and 150 0 C for 0.2 and 0.3 mm diameter Pt-Pt.Rh thermocouples, respectively, under a stagnant coolant condition. The fin effect increases with the decrease of vapor film thickness such as under forced flow cooling or at near the quenching point. (author)

  18. R and D advances in high temperature thermocouples for nuclear utilization in severe environment

    International Nuclear Information System (INIS)

    Schley, R.; Blanc, J.Y.

    1984-09-01

    Safety experiments for water reactors in Cadarache have made necessary a research program for developing special thermocouples for use in severe fuel damage conditions (superheated steam). Standard cladding thermocouples (type K, alumina insulated, zircaloy sheathed, O.D. 0.7 mm) must be replaced by others with W3Re versus W25Re legs, Ta sheath protected by a zircaloy outer sheath, and hafnia or thoria insulation. The zircaloy sheath will be sufficient to protect correctly tantalum. Fuel centerline thermocouples have W5Re versus W26Re or W3Re versus W25Re legs, hard-fired thoria insulation and rhenium CVD sheath (O.D. 1.1 mm). A protective ReSi 2 coating is applied. This protection withstands at least 1600 0 C, 45 minutes in steam. Tests are done-concerning: a) materials compatibilities in helium between 1400 0 C and 2000 0 C, b) prototypes qualification (in Saclay or Grenoble), c) determination of errors due to degradation of insulation resistance of thermocouples cables (with magnesia, hafnia, alumina), d) Ir or Re protective coatings by CVD process, other coatings by ionic bombardment, etc... A completely new type of hot junction has been patented. Future works will include: completion of these tests, Mo-Nb alloys thermocouples legs realization withstanding heavy neutronic fluence, and use of ceramics glues

  19. Thermocouple Errors when Mounted on Cylindrical Surfaces in Abnormal Thermal Environments.

    Energy Technology Data Exchange (ETDEWEB)

    Nakos, James T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Suo-Anttila, Jill M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zepper, Ethan T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Koenig, Jerry J [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Valdez, Vincent A. [ECI Inc., Albuquerque, NM (United States)

    2017-05-01

    Mineral-insulated, metal-sheathed, Type-K thermocouples are used to measure the temperature of various items in high-temperature environments, often exceeding 1000degC (1273 K). The thermocouple wires (chromel and alumel) are protected from the harsh environments by an Inconel sheath and magnesium oxide (MgO) insulation. The sheath and insulation are required for reliable measurements. Due to the sheath and MgO insulation, the temperature registered by the thermocouple is not the temperature of the surface of interest. In some cases, the error incurred is large enough to be of concern because these data are used for model validation, and thus the uncertainties of the data need to be well documented. This report documents the error using 0.062" and 0.040" diameter Inconel sheathed, Type-K thermocouples mounted on cylindrical surfaces (inside of a shroud, outside and inside of a mock test unit). After an initial transient, the thermocouple bias errors typically range only about +-1-2% of the reading in K. After all of the uncertainty sources have been included, the total uncertainty to 95% confidence, for shroud or test unit TCs in abnormal thermal environments, is about +-2% of the reading in K, lower than the +-3% typically used for flat shrouds. Recommendations are provided in Section 6 to facilitate interpretation and use of the results. .

  20. Relocation work of temporary thermocouples for measuring the vessel cooling system in the safety demonstration test

    International Nuclear Information System (INIS)

    Shimazaki, Yosuke; Shinohara, Masanori; Ono, Masato; Yanagi, Shunki; Tochio, Daisuke; Iigaki, Kazuhiko

    2012-05-01

    It is necessary to confirm that the temperature of water cooling panel of the vessel cooling system (VCS) is controlled under the allowable working temperature during the safety demonstration test because the water cooling panel temperature rises due to stop of cooling water circulation pumps. Therefore, several temporary thermocouples are relocated to the water cooling panel near the stabilizers of RPV and the side cooling panel outlet ring header of VCS in order to observe the temperature change of VCS. The relocated thermocouples can measure the temperature change with starting of the cooling water circulation pumps of VCS. So it is confirmed that the relocated thermocouples can observe the VCS temperature change in the safety demonstration test. (author)

  1. Difference equation approach to two-thermocouple sensor characterization in constant velocity flow environments

    International Nuclear Information System (INIS)

    Hung, P.C.; Irwin, G.; Kee, R.; McLoone, S.

    2005-01-01

    Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in certain harsh environments, for example, in combustion systems and engine exhausts, large wire diameters are required, and consequently the measurement bandwidth is reduced. This article discusses a software compensation technique to address the loss of high frequency fluctuations based on measurements from two thermocouples. In particular, a difference equation (DE) approach is proposed and compared with existing methods both in simulation and on experimental test rig data with constant flow velocity. It is found that the DE algorithm, combined with the use of generalized total least squares for parameter identification, provides better performance in terms of time constant estimation without any a priori assumption on the time constant ratios of the thermocouples

  2. Thermocouple Rakes for Measuring Boundary Layer Flows Extremely Close to Surface

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Blaha, Charles A.

    2001-01-01

    Of vital interest to aerodynamic researchers is precise knowledge of the flow velocity profile next to the surface. This information is needed for turbulence model development and the calculation of viscous shear force. Though many instruments can determine the flow velocity profile near the surface, none of them can make measurements closer than approximately 0.01 in. from the surface. The thermocouple boundary-layer rake can measure much closer to the surface than conventional instruments can, such as a total pressure boundary layer rake, hot wire, or hot film. By embedding the sensors (thermocouples) in the region where the velocity is equivalent to the velocity ahead of a constant thickness strut, the boundary-layer flow profile can be obtained. The present device fabricated at the NASA Glenn Research Center microsystem clean room has a heater made of platinum and thermocouples made of platinum and gold. Equal numbers of thermocouples are placed both upstream and downstream of the heater, so that the voltage generated by each pair at the same distance from the surface is indicative of the difference in temperature between the upstream and downstream thermocouple locations. This voltage differential is a function of the flow velocity, and like the conventional total pressure rake, it can provide the velocity profile. In order to measure flow extremely close to the surface, the strut is made of fused quartz with extremely low heat conductivity. A large size thermocouple boundary layer rake is shown in the following photo. The latest medium size sensors already provide smooth velocity profiles well into the boundary layer, as close as 0.0025 in. from the surface. This is about 4 times closer to the surface than the previously used total pressure rakes. This device also has the advantage of providing the flow profile of separated flow and also it is possible to measure simultaneous turbulence levels within the boundary layer.

  3. Analysis of heat transfer from fuel rods with externally attached thermocouples

    International Nuclear Information System (INIS)

    Gill, C.R.; Coddington, P.

    1988-05-01

    This paper describes the development of 2 and 3 dimensional finite element heat conduction models to simulate the behaviour of the external thermocouples attached to the LOFT fuel rods during the blowdown phase of a large break loss-of-coolant accident. To establish the model and determine the thermal coupling between the thermocouple and the fuel rod extensive use was made of two series of experiments performed at INEL in the LOFT Test Support Facility (LTSF). These experiments were high pressure reflood experiments with fluid conditions 'typical' of those seen during the bottom-up flow period of the LOFT experiments. (author)

  4. Determination of the availability of core exit thermocouples during severe accident situations

    International Nuclear Information System (INIS)

    Edson, J.L.

    1985-04-01

    This report presents the findings and recommendations of the Nuclear Power Plant Instrumentation Evaluation (NPPIE) program concerning signal validation methods to determine the on-line availability of core exit thermocouples during accident situations. Methods of selecting appropriate signal validation techniques are discussed and sources of error identified. This report shows that through the use of these techniques the existence of high-temperature-caused errors may be detected as they occur. Specific recommendations for application of selected signal validation techniques to core exit thermocouples and other measurement systems are made. 23 refs., 22 figs., 3 tabs

  5. Reply to ''Comment on 'Thermocouple temperature measurements in shock-compressed solids' ''

    International Nuclear Information System (INIS)

    Bloomquist, D.D.; Sheffield, S.A.

    1982-01-01

    We disagree with the interpretation offered in the above comment. The suggestion was made that the anomalously fast response of thin-foil thermocouples reported previously is the result of strain dependence of the thermocouple response and not shock enhanced thermal equilibration. Although the emplacement geometry has a profound effect on the response of embedded thin-foil temperature gauges as noted in the above comment, the evidence presented, along with recent results discussed in this reply, do not support the conclusions presented in the above comment

  6. Accuracy of small diameter sheathed thermocouples for the core flow test loop

    International Nuclear Information System (INIS)

    Anderson, R.L.; Kollie, T.G.

    1979-04-01

    This report summarizes the research and development on 0.5-mm-diameter, compacted, metal sheathed thermocouples. The objectives of this research effort have been: to identify and analyze the sources of temperature measurement errors in the use of 0.5-mm-diameter sheathed thermocouples to measure the surface temperature of the cladding of fuel-rod simulators in the Core Flow Test Loop (CFTL) at ORNL; to devise methods for reducing or correcting for these temperature measurement errors; to estimate the overall temperature measurement uncertainties; and to recommend modifications in the manufacture, installation, or materials used to minimize temperature measurement uncertainties in the CFTL experiments

  7. A Study of the Behavior Characteristics for K-type Thermocouple

    International Nuclear Information System (INIS)

    Ye, Songhae; Kim, Yongsik; Lee, Sooill; Kim, Sungjin; Lyou, Jooon

    2014-01-01

    K-type thermocouple is widely used in nuclear power plants (NPP) and they provide reliable service. Generally, the thermocouple assembly is the finished product and usually only nondestructive tests are performed on the assembly, whereas destructive tests are confined to selected bulk cable specimens. This K-type thermocouple has been used representatively in the In-Core Instrument Assembly (ICI) in the nuclear power plants. The ICI consists of five rhodium emitter detectors that provide information on the thermal power for the core and one K-type thermocouple made with two cables (Chromel-Alumel) that provides the temperature of core exit (CET). Generally, the quantity of the ICI is absolutely different according to the number of fuel assemblies in the NPP. In the case of SKN 3 and 4, they were designed to the 61 ICI to provide information on the core cooling to the inadequate core cooling monitoring system (ICCMS). This measured temperature could be also used to check the entry condition of severe accidents. The technology of the TFDR is a generic skill to detect the fault position of the cable. In-core Instruments (ICIs) were used to detect the Core Exit Temperature (CET) in a reactor. This measured temperature was also used to check the entry condition of severe accidents. However, if a serious accident occurs, the upper portion of the core is damaged. This instrument has not been available. This paper illustrates the estimation possibility for the status of molten core through the high-temperature characteristics test of k-type thermocouple. It turns out that it is possible to measure the k-type thermocouple up to 1350 .deg. C degrees before melting during insertion into the melting furnace. Additionally, in order to measure a high temperature of 2000 .deg. C or more, the replacement possibility of k-type thermocouple was evaluated. However the tungsten-rhenium thermocouple is impossible to use in the detection of temperature at the in-core because of the

  8. Development of thermocouple re-instrumentation technique for irradiated fuel rod. Techniques for making center hole into UO2 pellets and thermocouple re-instrumentation to fuel rod

    International Nuclear Information System (INIS)

    Shimizu, Michio; Saito, Junichi; Oshima, Kunio

    1995-07-01

    The information on FP gas pressure and centerline temperature of fuel pellets during power transient is important to study the pellet clad interaction (PCI) mechanism of high burnup LWR fuel rods. At the Department of JMTR, a re-instrumentation technique of FP gas pressure gage for an irradiated fuel rod was developed in 1990. Furthermore, a thermocouple re-instrumentation technique was successfully developed in 1994. Two steps were taken to carry out the development program of the thermocouple re-instrumentation technique. In the first step, a drilling technique was developed for making a center hole of the irradiated fuel pellets. Various drilling tests were carried out using dummy of fuel rods consisted of Ba 2 FeO 3 pellets and Zry-2 cladding. On this work it is important to keep the pellets just the state cracked at a power reactor. In these tests, the technique to fix the pellets by frozen CO 2 was used during the drilling work. Also, diamond drills were used to make the center hole. These tests were completed successfully. A center hole, 54mm depth and 2.5mm diameter, was realized by these methods. The second step of this program is the in-pile demonstration test on an irradiated fuel rod instrumented dually a thermocouple and FP gas pressure gage. The demonstration test was carried out at the JMTR in 1995. (author)

  9. Experiences with W3Re/W25Re thermocouples in fuel pins of NS Otto Hahn's two cores

    International Nuclear Information System (INIS)

    Kolb, M.

    1975-01-01

    Applications and performance of thermocouples in the Otto Hahn reactor are presented. The measurement of effective thermocouple time constants and of fuel rod heat transfer time constants utilizing the reactor noise and the resulting small temperature fluctuations which has become practical by the advent of modern noise analysis systems, is dealt with

  10. Low drift type N thermocouples in out-of-pile advanced gas reactor mock-up test: metallurgical analysis

    International Nuclear Information System (INIS)

    Scervini, M.; Palmer, J.; Haggard, D.C.; Swank, W.D.

    2015-01-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. As part of a collaboration between Idaho National Laboratory (INL) and the University of Cambridge a variety of Type N thermocouples have been exposed at INL in an Advanced Gas Reactor mock-up test at 1150 deg. C for 2000 h, 1200 deg. C for 2000 h, 125 deg. C for 200 h and 1300 deg. C for 200 h, and later analysed metallurgically at the University of Cambridge. The use of electron microscopy allows to identify the metallurgical changes occurring in the thermocouples during high temperature exposure and correlate the time dependent thermocouple drift with the microscopic changes experienced by the thermoelements of different thermocouple designs. In this paper conventional Inconel 600 sheathed type N thermocouples and a type N using a customized sheath developed at the University of

  11. Low drift type N thermocouples in out-of-pile advanced gas reactor mock-up test: metallurgical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Scervini, M. [University of Cambridge, Department of Materials Science and Metallurgy, 27 Charles Babbage Road, CB30FS Cambridge, (United Kingdom); Palmer, J.; Haggard, D.C.; Swank, W.D. [Idaho National Laboratory, Idaho Falls, ID 83415-3840, (United States)

    2015-07-01

    Thermocouples are the most commonly used sensors for temperature measurement in nuclear reactors. They are crucial for the control of current nuclear reactors and for the development of GEN IV reactors. In nuclear applications thermocouples are strongly affected by intense neutron fluxes. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. Thermocouple drift can be very significant for in-pile temperature measurements and may render the temperature sensors unreliable after exposure to nuclear radiation for relatively short times compared to the life required for temperature sensors in nuclear applications. Previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of Nickel based thermocouples is limited to temperatures lower than 1000 deg. C due to drift related to phenomena other than nuclear irradiation. As part of a collaboration between Idaho National Laboratory (INL) and the University of Cambridge a variety of Type N thermocouples have been exposed at INL in an Advanced Gas Reactor mock-up test at 1150 deg. C for 2000 h, 1200 deg. C for 2000 h, 125 deg. C for 200 h and 1300 deg. C for 200 h, and later analysed metallurgically at the University of Cambridge. The use of electron microscopy allows to identify the metallurgical changes occurring in the thermocouples during high temperature exposure and correlate the time dependent thermocouple drift with the microscopic changes experienced by the thermoelements of different thermocouple designs. In this paper conventional Inconel 600 sheathed type N thermocouples and a type N using a customized sheath developed at the University of

  12. Computer subroutines to aid analysis of experimental data from thermocouples and pressure transducers

    International Nuclear Information System (INIS)

    Durham, M.E.

    1976-08-01

    Three subroutines (CALSET, CALBR8 and PTRCAL) have been written to provide a convenient system for converting experimental measurements obtained from thermocouples and pressure transducers to temperatures and pressures. The method of operation and the application of the subroutines are described. (author)

  13. Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography

    International Nuclear Information System (INIS)

    Fernandes, Alex de Andrade; Amorim, Paulo Roberto dos Santos; De Moura, Anselmo Gomes; Moreira, Danilo Gomes; Costa, Carlos Magno Amaral; Marins, João Carlos Bouzas; Brito, Ciro José; Sillero-Quintana, Manuel

    2014-01-01

    Measuring skin temperature (T SK ) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record T SK  involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure T SK , and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MT SK ) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland–Altman plots showed poor agreement between the MT SK  obtained using thermocouples and those using IRT. The averaged error was −0.75 °C during pre-exercise, 1.22 °C during exercise and −1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [−0.80 to 0.85]) and post-exercise (ICC = 0.35 [−1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MT SK  measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement. (paper)

  14. Direct Measurement of Neutral/Ion Beam Power using Thermocouple Analysis

    International Nuclear Information System (INIS)

    Day, I.; Gee, S.

    2006-01-01

    Modern Neutral Beam Injection systems such as those used on JET and MAST routinely use thermocouples embedded close to the surface of beam stopping elements, such as calorimeters and ion dumps, coupled to high speed data acquisition systems to determine beam profile and position from temperature rise data. With the availability of low cost data acquisition and storage systems it is now possible to record data from all thermocouples in a fully instrumented calorimeter or ion dump on 20 ms timescales or better. This sample rate is sufficiently fast to enable the thermocouple data to be used to calculate the incident power density from 1d heat transfer theory. This power density data coupled with appropriate Gaussian fits enables the determination of the 2d beam profile and thus allows an instantaneous and direct measurement of beam power. The theory and methodology required to analyse the fast thermocouple data from the MAST calorimeter and residual ion dump thermocouples is presented and direct measurements of beam power density are demonstrated. The power of desktop computers allows such analysis to be carried out virtually instantaneously. The methods used to automate this analysis are discussed in detail. A code, utilising the theory and methodology, has been developed to allow immediate measurements of beam power on a pulse by pulse basis. The uncertainty in determining the beam power density is shown to be less than 10 %. This power density data is then fitted to a 2d Gaussian beam profile and integrated to establish the total beam power. Results of this automated analysis for the neutral beam and residual ion power of the MAST duopigatron and PINI NBI systems are presented. This technology could be applied to a beam power safety interlock system. The application to a beam shine through protection system for the inner wall of the JET Tokamak is discussed as an example. (author)

  15. Thermal Recovery from Cold-Working in Type K Bare-Wire Thermocouples

    Science.gov (United States)

    Greenen, A. D.; Webster, E. S.

    2017-12-01

    Cold-working of most thermocouples has a significant, direct impact on the Seebeck coefficient which can lead to regions of thermoelectric inhomogeneity and accelerated drift. Cold-working can occur during the wire swaging process, when winding the wire onto a bobbin, or during handling by the end user—either accidentally or deliberately. Swaging-induced cold-work in thermocouples, if uniformly applied, may result in a high level of homogeneity. However, on exposure to elevated temperatures, the subsequent recovery process from the cold-working can then result in significant drift, and this can in turn lead to erroneous temperature measurements, often in excess of the specified manufacturer tolerances. Several studies have investigated the effects of cold-work in Type K thermocouples usually by bending, or swaging. However, the amount of cold-work applied to the thermocouple is often difficult to quantify, as the mechanisms for applying the strains are typically nonlinear when applied in this fashion. A repeatable level of cold-working is applied to the different wires using a tensional loading apparatus to apply a known yield displacement to the thermoelements. The effects of thermal recovery from cold-working can then be accurately quantified as a function of temperature, using a linear gradient furnace and a high-resolution homogeneity scanner. Variation in these effects due to differing alloy compositions in Type K wire is also explored, which is obtained by sourcing wire from a selection of manufacturers. The information gathered in this way will inform users of Type K thermocouples about the potential consequences of varying levels of cold-working and its impact on the Seebeck coefficient at a range of temperatures between ˜ 70°C and 600° C. This study will also guide users on the temperatures required to rapidly alleviate the effects of cold-working using thermal annealing treatments.

  16. External attachment of titanium sheathed thermocouples to zirconium nuclear fuel rods for the LOFT reactor

    International Nuclear Information System (INIS)

    Welty, R.K.

    1980-01-01

    The Exxon Nuclear Company, Inc., acting as a Subcontractor to EG and G Idaho Inc., Idaho National Engineering Laboratory, Idaho Falls, Idaho, has developed a welding process to attach titanium sheathed thermocouples to the outside of the zircaloy clad fuel rods. The fuel rods and thermocouples are used to test simulated loss-of-coolant accident (LOCA) conditions in a pressurized water reactor (LOFT Reactor, Idaho National Laboratory). A laser beam was selected as the optimum welding process because of the extremely high energy input per unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. A commercial pulsed laser and energy control system was installed along with specialized welding fixtures. Laser room facility requirements and tolerances were established. Performance qualifications, and detailed welding procedures were also developed. Product performance tests were conducted to assure that engineering design requirements could be met on a production basis

  17. Proposed algorithm for determining the delta intercept of a thermocouple psychrometer curve

    International Nuclear Information System (INIS)

    Kurzmack, M.A.

    1993-01-01

    The USGS Hydrologic Investigations Program is currently developing instrumentation to study the unsaturated zone at Yucca Mountain in Nevada. Surface-based boreholes up to 2,500 feet in depth will be drilled, and then instrumented in order to define the water potential field within the unsaturated zone. Thermocouple psychrometers will be used to monitor the in-situ water potential. An algorithm is proposed for simply and efficiently reducing a six wire thermocouple psychrometer voltage output curve to a single value, the delta intercept. The algorithm identifies a plateau region in the psychrometer curve and extrapolates a linear regression back to the initial start of relaxation. When properly conditioned for the measurements being made, the algorithm results in reasonable results even with incomplete or noisy psychrometer curves over a 1 to 60 bar range

  18. Attachment of Free Filament Thermocouples for Temperature Measurements on Ceramic Matrix Composites

    Science.gov (United States)

    Lei, Jih-Fen; Cuy, Michael D.; Wnuk, Stephen P.

    1998-01-01

    At the NASA Lewis Research Center, a new installation technique utilizing convoluted wire thermocouples (TC's) was developed and proven to produce very good adhesion on CMC's, even in a burner rig environment. Because of their unique convoluted design, such TC's of various types and sizes adhere to flat or curved CMC specimens with no sign of delamination, open circuits, or interactions-even after testing in a Mach 0.3 burner rig to 1200 C (2200 F) for several thermal cycles and at several hours at high temperatures. Large differences in thermal expansion between metal thermocouples and low-expansion materials, such as CMC's, normally generate large stresses in the wires. These stresses cause straight wires to detach, but convoluted wires that are bonded with strips of coating allow bending in the unbonded portion to relieve these expansion stresses.

  19. A Simple Test to Evaluate the Calibration Stability and Accuracy of Infrared Thermocouple Sensors

    OpenAIRE

    Pinnock, Derek R.; Bugbee, Bruce

    2002-01-01

    Accurately measuring surface temperature is not difficult when the surface, the sensor, and air temperatures are similar, but it is challenging when the surface temperature is significantly different than air and sensor temperatures. We tested three Infrared Thermocouple sensors (IRT’s) that had been used for two years in a greenhouse environment. The importance of the correction for sensor body temperature was also examined.

  20. R and D advances in high temperature thermocouples for nuclear utilization in severe environment

    International Nuclear Information System (INIS)

    Schley, R.; Blanc, J.Y.

    1985-01-01

    Safety experiments for water reactors in Cadarache have made necessary a research program for developing special thermocopules for use in severe fuel damage conditions (superheated steam). Standard cladding thermocouples (type K, alumina insulated, zircaloy sheathed, O.D. 0.7 mm) must be replaced by others with W3Re versus W25Re legs, Ta sheath protected by a zircaloy outer sheath, and hafnia or thoria insulation. The zircaloy sheath will be sufficient to protect correctly tantalum. Fuel centerline thermocouples have W5Re versus W26Re or W3Re versus W25Re legs, hard-fired thoria insulation and rhenium CVD sheath (O.D. 1.1 mm). A protective ReSi/sub 2/ coating is applied. This protection withstands at least 1600 0 C, 45 minutes in steam. Tests are done concerning: (a) materials compatibilities in helium between 1400 0 C and 2000 0 C, (b) prototypes qualification (In Saclay or Grenoble), (c) determination of errors due to degradation of insulation resistance of thermocouples cables (with magnesia, hafnia, alumina), (d) Ir or Re protective coatings by CVD process, other coatings by ionic bombardment, etc...A completely new type of hot junction has been patented

  1. A Highly Thermostable In2O3/ITO Thin Film Thermocouple Prepared via Screen Printing for High Temperature Measurements

    Directory of Open Access Journals (Sweden)

    Yantao Liu

    2018-03-01

    Full Text Available An In2O3/ITO thin film thermocouple was prepared via screen printing. Glass additives were added to improve the sintering process and to increase the density of the In2O3/ITO films. The surface and cross-sectional images indicate that both the grain size and densification of the ITO and In2O3 films increased with the increase in annealing time. The thermoelectric voltage of the In2O3/ITO thermocouple was 53.5 mV at 1270 °C at the hot junction. The average Seebeck coefficient of the thermocouple was calculated as 44.5 μV/°C. The drift rate of the In2O3/ITO thermocouple was 5.44 °C/h at a measuring time of 10 h at 1270 °C.

  2. Thermocouples used in emission systems of internal combustion engines; Thermoelemente fuer den Einsatz in Abgassystemen von Verbrennungsmotoren

    Energy Technology Data Exchange (ETDEWEB)

    Augustin, Silke; Froehlich, Thomas; Mammen, Helge [Technische Univ. Illmenau (Germany). Inst. fuer Prozessmess- und Sensortechnik; Ament, Christoph; Guether, Thomas [Technische Univ. Illmenau (Germany). Inst. fuer Automatisierungs- und Systemtechnik

    2012-11-01

    Thermocouples used in exhaust systems of combustion engines are exposed to high temperature gradients and temperature leaps ({Delta}T > 900 K), high flow speeds and pressure. When constructing these thermocouples, a compromise is needed between the resulting high demands on the mechanical-thermal stability, accuracy and the fast response time demanded by the servo-control of the motors. Additionally, a numerical correction of the measured signal may contribute to an improved sensor dynamics. (orig.)

  3. A novel method for in-situ estimation of time constant for core temperature monitoring thermocouples of operating reactors

    International Nuclear Information System (INIS)

    Sylvia, J.I.; Chandar, S. Clement Ravi; Velusamy, K.

    2014-01-01

    Highlights: • Core temperature sensor was mathematically modeled. • Ramp signal generated during reactor operating condition is used. • Procedure and methodology has been demonstrated by applying it to FBTR. • Same technique will be implemented for all fast reactors. - Abstract: Core temperature monitoring system is an important component of reactor protection system in the current generation fast reactors. In this system, multiple thermocouples are housed inside a thermowell of fuel subassemblies. Response time of the thermocouple assembly forms an important input for safety analysis of fast reactor and hence frequent calibration/time constant estimation is essential. In fast reactors the central fuel subassembly is provided with bare fast response thermocouples to detect under cooling events in reactor and take proper safety action. On the other hand, thermocouples in thermowell are mainly used for blockage detection in individual fuel subassemblies. The time constant of thermocouples in thermowell can drift due to creep, vibration and thermal fatigue of the thermowell assembly. A novel method for in-situ estimation of time constant is proposed. This method uses the Safety Control Rod Accelerated Mechanism (SCRAM) or lowering of control Rod (LOR) signals of the reactor along with response of the central subassembly thermocouples as reference data. Validation of the procedure has been demonstrated by applying it to FBTR

  4. A preliminary study of factors affecting the calibration stability of the iridium versus iridium-40 percent rhodium thermocouple

    Science.gov (United States)

    Ahmed, Shaffiq; Germain, Edward F.; Daryabeigi, Kamran; Alderfer, David W.; Wright, Robert E.

    1987-01-01

    An iridium versus iridium-40% rhodium thermocouple was studied. Problems associated with the use of this thermocouple for high temperature applications (up to 2000 C) were investigated. The metallurgical studies included X-ray, macroscopic, resistance, and metallographic studies. The thermocouples in the as-received condition from the manufacturer revealed large amounts of internal stress caused by cold working during manufacturing. The thermocouples also contained a large amount of inhomogeneities and segregations. No phase transformations were observed in the alloy up to 1100 C. It was found that annealing the thermocouple at 1800 C for two hours, and then at 1400 C for 2 to 3 hours yielded a fine grain structure, relieving some of the strains, and making the wire more ductile. It was also found that the above annealing procedure stabilized the thermal emf behavior of the thermocouple for application below 1800 C (an improvement from + or - 1% to + or - 0.02% within the range of the test parameters used).

  5. COMPARATIVE EFFICАCY AND TOLERABILITY OF MONOTHERAPY WITH DEPAKINE CHRONOSPHERE, DRUGS OF CARBAMAZEPINE GROUP WITH EXTENDED RELEASE AND OXCARBAZEPINE IN SYMPTOMATIC AND CRYPTOGENIC FOCAL EPILEPSY (SVT. LUKA’S INSTITUTE OF CHILD NEUROLOGY AND EPILEPSY

    Directory of Open Access Journals (Sweden)

    K. Yu. Mukhin

    2015-01-01

    Full Text Available Research on comparative efficаcy and tolerability of monotherapy with Depakine chronosphere, drugs of Carbamazepine group with extended release and oxcarbazepine in symptomatic and cryptogenic focal epilepsy has been conducted at Svt. Luka’s Institute of Child Neurology and Epilepsy (ICNE (Moscow. This retrospective study covers a random sample of patients treated in ICNE in the period from December 1, 2013 to September 1, 2014.  The study included 131 patients aged 1 to 18 years with symptomatic and cryptogenic focal epilepsy receiving treatment with one of the study drugs in monotherapy: group 1 – monotherapy with Depakine chronosphere (n = 56; group 2 – monotherapy with drugs of carbamazepine group with extended release (n = 55; group 3 – monotherapy with oxcarbazepine (trileptal (n = 20. The obtained results allow us to conclude that the effectiveness of Depakin chronosphere, carbamazepine with extended release and oxcarbazepine in monotherapy of symptomatic and cryptogenic focal epilepsy was comparable (statistically significant differences in efficacy were not found. However, carbamazepine was awarded the highest frequency of seizures aggravation. Drugs showed approximately same tolerability (statistically significant differences in tolerability were not found. However, withdrawal of the drug due to side effects was the rarest in Depakine (3.5 %, and withdrawal due to intolerance was higher in carbamazepine and oxcarbazepine (5 and 10 % respectively. Depakinum and oxcarbazepine had the best results in the blocking of pathological activity on the electroencephalogram, whereas carbamazepine was clearly inferior to them. In this regard, complete clinical-electroencephalographic remission (lasting 12 months or more was achieved under treatment of Depakine chromosphere in 21.5 % of cases, oxcarbazepi on therapy for 12 months was similar in all study drugs. Considering that the objective of epilepsy treatment is to achieve complete

  6. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    International Nuclear Information System (INIS)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho

    2015-01-01

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system

  7. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system.

  8. An Explicit Approach Toward Modeling Thermo-Coupled Deformation Behaviors of SMPs

    Directory of Open Access Journals (Sweden)

    Hao Li

    2017-03-01

    Full Text Available A new elastoplastic J 2 -flow models with thermal effects is proposed toward simulating thermo-coupled finite deformation behaviors of shape memory polymers. In this new model, an elastic potential evolving with development of plastic flow is incorporated to characterize the stress-softening effect at unloading and, moreover, thermo-induced plastic flow is introduced to represent the strain recovery effect at heating. It is shown that any given test data for both effects may be accurately simulated by means of direct and explicit procedures. Numerical examples for model predictions compare well with test data in literature.

  9. Improvement in the technology of thermocouples for the detection of high temperatures with a view to using them in irradiation safety tests in reactor

    International Nuclear Information System (INIS)

    Schley, R.; Liermann, J.; Aujollet, J.M.; Wilkins, S.C.

    1979-01-01

    The safety tests carried out under the CABRI and PHEBUS programmes have made it possible to improve the technology of W/Re thermocouples and their reliability in particularly hard operating conditions. An element of response is provided to the problem of W/Re thermocouple drift under neutron flux by defining the new thermocouple Mo 5% Nb/Nb 10% Mo which, because of the low capture cross section of thermoelectric elements, gives one reason to hope for a less significant drift of these thermocouples under neutron flux than that found with W/Re thermocouples. Finally, determining the surface temperature of fuel element cladding with the Mo/Zircaloy thermocouple may prove worthwhile providing the temperatures do not exceed 1300 0 C and the electric insulator is aluminium oxide which up to 1300 0 C does not appear to react with thermoelectric wires [fr

  10. Experience from replacement and check of thermocouples during reconstruction of in-reactor temperature measurements at Bohunice V-1 units 1 and 2

    International Nuclear Information System (INIS)

    Slanina, M.; Stanc, J.

    2001-01-01

    Replacement of thermocouples in the protection tube blocks was a key phase of the reconstruction of in-reactor temperature measurements at Bohunice V-1 with regard to the success, reliability and impact on safety of unit operation. The replacement consisted of reliable and safe withdrawal of 216 old thermocouples, their disposal and installation of new thermocouples into dry channels. In the material presented, this phase of reconstruction is described in details, with focus on the evaluation of replacement quality and check activities carried out at the new installed thermocouples. (Authors)

  11. Calibration of the Dodewaard downcomer thermocouple cross-correlation flow-rate measurements

    Energy Technology Data Exchange (ETDEWEB)

    Stekelenburg, A J.C. [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.; Hagen, T.H.J.J. van der [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.; Akker, H.E.A. van den [Technische Univ. Delft (Netherlands). Lab. voor Fysische Technologie

    1992-12-01

    The cross-correlation flow measurement technique, applied for measuring the coolant flow rate in a nuclear reactor, was calibrated with the use of numerical simulations of turbulent flow. The three-dimensional domain was collapsed into two dimensions. With a two-dimensional calculation of steady-state flow with transient thermal characteristics the response of thermocouples to a temperature variation was calculated. By cross-correlating the calculated thermocouple responses, the link between total flow rate and measured transit times was made. Three calibration points were taken in the range of 579 kg/s to 1477 kg/s. In this range, the product of the calculated transit time and the mass flow-rate is constant up to +3.5% and -2.4%. The reliability of the calibration was estimated at {+-}4.6%. The influence of the inlet boundary conditions, and the modelling of the flow in the upper part of the downcomer channel on the calibration result is shown to be small. A measured velocity profile effect was successfully predicted. (orig.).

  12. Comparative evaluation of corrosion behaviour of type K thin film thermocouple and its bulk counterpart

    International Nuclear Information System (INIS)

    Mukherjee, S.K.; Barhai, P.K.; Srikanth, S.

    2011-01-01

    Highlights: → Anodic vacuum arc deposited chromel and alumel films are more 'noble' in 5% NaCl solution than their respective wires. → Chromel undergoes localised corrosion while alumel shows uniform corrosion. → Virgin samples of chromel-alumel TFTCs exhibit good thermoelectric response. → Their thermoelectric outputs remain largely unaffected when shelved under normal atmospheric conditions. → After 288 h of exposure in salt spray environment, their thermoelectric outputs show noticeable change due to size effects. - Abstract: This paper investigates the corrosion behaviour of type K thermoelements and their thin films, and compares the performance of chromel-alumel thin film thermocouple with its wire counterpart before and after exposure to 5% NaCl medium. Potentiodynamic polarisation tests reveal that chromel and alumel films are more 'noble' than their respective wires. Alumel corrodes faster when coupled with chromel in films than as wires. Secondary electron micrographs and electrochemical impedance spectroscopy measurements suggest that chromel shows localised corrosion while alumel undergoes uniform corrosion. Corrosion adversely affects the thermocouple output and introduces an uncertainty in the measurement.

  13. Experience with W3Re/W25Re thermocouples in fuel pins of NS Otto Hahn's two cores

    International Nuclear Information System (INIS)

    Kolb, M.

    1976-01-01

    The paper first deals with the installation of 18 and 9 high-temperature sheathed thermocouples in fuel rods of the cores FDR-1 and FDR-2, respectively. The measured fuel rod centerline temperatures could be related to the local linear rod power at any given time by means of the densities of fission products with different half-lives obtained from fuel rod γ-scans. The fuel temperatures show then already an increase with the burn-up of the FDR-1 which becomes steeper when taking into account the decrease of the EMF measured at irradiated thermocouples taken from the fuel rods. Finally, the determination of effective thermocouple time constants and of fuel rod heat transfer time constants is demonstrated by utilizing the reactor noise to measure the transfer function between neutron flux and fuel temperature signal. (orig.) [de

  14. Apparatus for spot welding sheathed thermocouples to the inside of small-diameter tubes at precise locations

    International Nuclear Information System (INIS)

    Baucum, W.E.; Dial, R.E.

    1976-01-01

    Equipment and procedures used to spot weld tantalum- or stainless-steel-sheathed thermocouples to the inside diameter of Zircaloy tubing to meet the requirements of the Multirod Burst Test (MRBT) Program at ORNL are described. Spot welding and oxide cleaning tools were fabricated to remove the oxide coating on the Zircaloy tubing at local areas and spot weld four thermocouples separated circumferentially by 90 0 at any axial distribution desired. It was found necessary to apply a nickel coating to stainless-steel-sheathed thermocouples to obtain acceptable welds. The material and shape of the inner electrode and resistance between inner and outer electrodes were found to be critical parameters in obtaining acceptable welds

  15. Protection of Mobile Agents Execution Using a Modified Self-Validating Branch-Based Software Watermarking with External Sentinel

    Science.gov (United States)

    Tomàs-Buliart, Joan; Fernández, Marcel; Soriano, Miguel

    Critical infrastructures are usually controlled by software entities. To monitor the well-function of these entities, a solution based in the use of mobile agents is proposed. Some proposals to detect modifications of mobile agents, as digital signature of code, exist but they are oriented to protect software against modification or to verify that an agent have been executed correctly. The aim of our proposal is to guarantee that the software is being executed correctly by a non trusted host. The way proposed to achieve this objective is by the improvement of the Self-Validating Branch-Based Software Watermarking by Myles et al.. The proposed modification is the incorporation of an external element called sentinel which controls branch targets. This technique applied in mobile agents can guarantee the correct operation of an agent or, at least, can detect suspicious behaviours of a malicious host during the execution of the agent instead of detecting when the execution of the agent have finished.

  16. Self-validated calculation of characteristics of a Francis turbine and the mechanism of the S-shape operational instability

    International Nuclear Information System (INIS)

    Zhang, Z; Titzschkau, M

    2012-01-01

    A calculation method has been presented to accurately estimate the characteristics of a Francis turbine. Both the shock loss at the impeller inlet and the swirling flow loss at the Impeller exit have been confirmed to dominantly influence the turbine characteristics and particularly the hydraulic efficiency. Both together totally govern the through flow of water through the impeller being at the rest. Calculations have been performed for the flow rate, the shaft torque and the hydraulic efficiency and compared with the available measurements on a model turbine. Excellent agreements have been achieved. Some other interesting properties of the turbine characteristics could also be derived from the calculations and verified by experiments. For this reason and because of not using any unreliable assumptions the calculation method has been confirmed to be self-validated. The operational instability in the upper range of the rotational speed, known as the S-shape instability, is ascribed to the total flow separation and stagnation at the impeller inlet. In that range of the rotational speed, the operation of the Francis turbine oscillates between pump and turbine mode.

  17. A preliminary study of oxidation-resistant coatings on refractory-metal thermocouple sheaths

    International Nuclear Information System (INIS)

    Wilkins, S.C.

    1985-01-01

    The need to make reliable temperature measurements up to 2200 0 C or higher in steam environments during in-pile nuclear fuel damage tests led to a search for oxidation-resistant coatings for the refractory-metal sheaths used to enclose and protect thermocouples used for such measurements. Iridium, thoria, and thoria-over-iridium coatings were separately sputter-deposited on molybdenum-rhenium alloy protection tubes for evaluation. The coated samples were individually heated in flowing steam in an induction furnace. An extension tube welded to each sample was connected to a vacuum pump and gauge; failure of the sample was detected by noting the degradation of the vacuum maintained in the sample. Relatively heavy coatings of iridium provided a modest degree of oxidation protection at the temperatures of interest. Thoria coatings provided no significant protection at those temperatures, compared to uncoated control samples

  18. W-1 Sodium Loop Safety Facility experiment centerline fuel thermocouple performance

    International Nuclear Information System (INIS)

    Meyers, S.C.; Henderson, J.M.

    1980-05-01

    The W-1 Sodium Loop Safety Facility (SLSF) experiment is the fifth in a series of experiments sponsored by the Department of Energy (DOE) as part of the National Fast Breeder Reactor (FBR) Safety Assurance Program. The experiments are being conducted under the direction of Argonne National Laboratory (ANL) and Hanford Engineering Development Laboratory (HEDL). The irradiation phase of the W-1 SLSF experiment was conducted between May 27 and July 20, 1979, and terminated with incipient fuel pin cladding failure during the final boiling transient. Experimental hardware and facility performed as designed, allowing completion of all planned tests and test objectives. This paper focuses on high temperature in-fuel thermocouples and discusses their development, fabrication, and performance in the W-1 experiment

  19. Boiling detection using signals of self-powered neutron detectors and thermocouples

    International Nuclear Information System (INIS)

    Kozma, R.

    1989-01-01

    A specially-equipped simulated fuel assembly has been placed into the core of the 2 MW research reactor of the IRI, Delft. In this paper the recent results concerning the detection of coolant boiling in the simulated fuel assembly are introduced. Applying the theory of boiling temperature noise, different stages of boiling, i.e. one-phase flow, subcooled boiling, volume boiling, were identified in the measurements using the low-frequency noise components of the thermocouple signals. It has been ascertained that neutron noise spectra remained unchanged when subcooled boiling appeared, and that they changed reasonably only when developed volume boiling took place in the channels. At certain neutron detector positions neutron spectra did not vary at all, although developed volume boiling occurred at a distance of 3-4 cm from these neutron detectors. This phenomenon was applied in studying the field-of-view of neutron detectors

  20. Preparation and Thermoelectric Characteristics of ITO/PtRh:PtRh Thin Film Thermocouple.

    Science.gov (United States)

    Zhao, Xiaohui; Wang, Hongmin; Zhao, Zixiang; Zhang, Wanli; Jiang, Hongchuan

    2017-12-15

    Thin film thermocouples (TFTCs) can provide more precise in situ temperature measurement for aerospace propulsion systems without disturbance of gas flow and surface temperature distribution of the hot components. ITO/PtRh:PtRh TFTC with multilayer structure was deposited on alumina ceramic substrate by magnetron sputtering. After annealing, the TFTC was statically calibrated for multiple cycles with temperature up to 1000 °C. The TFTC with excellent stability and repeatability was realized for the negligible variation of EMF in different calibration cycles. It is believed that owing to oxygen diffusion barriers by the oxidation of top PtRh layer and Schottky barriers formed at the grain boundaries of ITO, the variation of the carrier concentration of ITO film is minimized. Meanwhile, the life time of TFTC is more than 30 h in harsh environment. This makes ITO/PtRh:PtRh TFTC a promising candidate for precise surface temperature measurement of hot components of aeroengines.

  1. Energy deposition measurements in fast reactor safety experiments with fission thermocouple detectors

    International Nuclear Information System (INIS)

    Wright, S.A.; Scott, H.L.

    1979-01-01

    The investigation of phenomena occurring in in-pile fast reactor safety experiments requires an accurate measurement of the time dependent energy depositions within the fissile material. At Sandia Laboratories thin-film fission thermocouples are being developed for this purpose. These detectors have high temperature capabilities (400 to 500 0 C), are sodium compatible, and have milli-second time response. A significant advantage of these detectors for use as energy deposition monitors is that they produce an output voltage which is directly dependent on the temperature of a small chip of fissile material within the detectors. However, heat losses within the detector make it necessary to correct the response of the detector to determine the energy deposition. A method of correcting the detector response which uses an inverse convolution procedure has been developed and successfully tested with experimental data obtained in the Sandia Pulse Reactor (SPR-II) and in the Annular Core Research Reactor

  2. Tile Surface Thermocouple Measurement Challenges from the Orbiter Boundary Layer Transition Flight Experiment

    Science.gov (United States)

    Campbell, Charles H.; Berger, Karen; Anderson, Brian

    2012-01-01

    Hypersonic entry flight testing motivated by efforts seeking to characterize boundary layer transition on the Space Shuttle Orbiters have identified challenges in our ability to acquire high quality quantitative surface temperature measurements versus time. Five missions near the end of the Space Shuttle Program implemented a tile surface protuberance as a boundary layer trip together with tile surface thermocouples to capture temperature measurements during entry. Similar engineering implementations of these measurements on Discovery and Endeavor demonstrated unexpected measurement voltage response during the high heating portion of the entry trajectory. An assessment has been performed to characterize possible causes of the issues experienced during STS-119, STS-128, STS-131, STS-133 and STS-134 as well as similar issues encountered during other orbiter entries.

  3. Operating Temperatures of a Sodium-Cooled Exhaust Valve as Measured by a Thermocouple

    Science.gov (United States)

    Sanders, J. C.; Wilsted, H. D.; Mulcahy, B. A.

    1943-01-01

    A thermocouple was installed in the crown of a sodium-cooled exhaust valve. The valve was then tested in an air-cooled engine cylinder and valve temperatures under various engine operating conditions were determined. A temperature of 1337 F was observed at a fuel-air ratio of 0.064, a brake mean effective pressure of 179 pounds per square inch, and an engine speed of 2000 rpm. Fuel-air ratio was found to have a large influence on valve temperature, but cooling-air pressure and variation in spark advance had little effect. An increase in engine power by change of speed or mean effective pressure increased the valve temperature. It was found that the temperature of the rear spark-plug bushing was not a satisfactory indication of the temperature of the exhaust valve.

  4. Low-noise audio amplifiers and preamplifier for use with intrinsic thermocouples

    International Nuclear Information System (INIS)

    Langner, G.C.; Sachs, R.D.; Stewart, F.L.

    1979-03-01

    Two simple, low-noise audio amplifiers and one low-noise preamplifier for use with intrinsic thermocouples were designed, built, and tested. The amplifiers and the preamplifier have different front end designs. One amplifier uses ultralow-noise operational amplifiers; the other amplifier uses a hybrid component. The preamplifier uses ultralow-noise discrete components. The amplifiers' equivalent noise inputs, at maximum gain, are 4.09 nV and 50 nV; the preamplifier's input is 4.05 μV. Their bandwidths are 15 600 Hz, 550 Hz, and 174 kHz, respectively. the amplifiers' equivalent noise inputs were measured from approx. 0 to 100 Hz, whereas the preamplifier's equivalent noise input was measured from approx. 0 to 174 kHz

  5. SMORN-1: thermoelectrically generated noise in sheathed thermocouples and in other low level instrumentation cables

    International Nuclear Information System (INIS)

    Mathieu, F.; Meier, R.; Soenen, M.; Delcon, M.; Nysten, C.

    Starting from the fact that thermoelectric emfs of thermocouples are generated in the thermal gradients and not at the hot junction, it is shown how thermoelectric heterogeneity in conjunction with natural and forced convection phenomena gives rise to unwanted noise called: ''thermoelectric noise'' in the technological sense. A distinction is made between four different types of noise--i.e. uncorrelated noise, correlated noise, spectral noise and thermoelectric noise in the physical sense--each of which has its own characteristics. The experimental results presented reveal that noise amplitudes may be quite embarrassing when dealing with problems of quantitative signal fluctuation analysis. It is however emphasized that thermoelectric noise may also convey useful information which, without noise, might be lost

  6. Boiling point measurement of a small amount of brake fluid by thermocouple and its application.

    Science.gov (United States)

    Mogami, Kazunari

    2002-09-01

    This study describes a new method for measuring the boiling point of a small amount of brake fluid using a thermocouple and a pear shaped flask. The boiling point of brake fluid was directly measured with an accuracy that was within approximately 3 C of that determined by the Japanese Industrial Standards method, even though the sample volume was only a few milliliters. The method was applied to measure the boiling points of brake fluid samples from automobiles. It was clear that the boiling points of brake fluid from some automobiles dropped to approximately 140 C from about 230 C, and that one of the samples from the wheel cylinder was approximately 45 C lower than brake fluid from the reserve tank. It is essential to take samples from the wheel cylinder, as this is most easily subjected to heating.

  7. Specific features of thermocouple calorimeter application for measurements of pulsed X-ray emission from plasma

    International Nuclear Information System (INIS)

    Gavrilov, V. V.; Fasakhov, I. K.

    2012-01-01

    It is shown that the accuracy of time-integrated measurements of pulsed X-ray emission from hot plasma with calibrated thermocouple calorimeters is mainly determined by two factors. The first and the most important factor is heating of the filter by the absorbed X-rays; as a result, the calorimeter measures the thermal radiation of the filter, which causes appreciable distortion of the temporal profile and amplitude of the recorded signal. The second factor is the dependence of the effective depth of X-ray absorption in the dielectric that covers the entrance window of the calorimeter on the energy of X-ray photons, i.e., on the recorded radiation spectrum. The results of model calculations of the calorimeter signal are compared with the experimental data.

  8. Co-C and Pd-C Eutectic Fixed Points for Radiation Thermometry and Thermocouple Thermometry

    Science.gov (United States)

    Wang, L.

    2017-12-01

    Two Co-C and Pd-C eutectic fixed point cells for both radiation thermometry and thermocouple thermometry were constructed at NMC. This paper describes details of the cell design, materials used, and fabrication of the cells. The melting curves of the Co-C and Pd-C cells were measured with a reference radiation thermometer realized in both a single-zone furnace and a three-zone furnace in order to investigate furnace effect. The transition temperatures in terms of ITS-90 were determined to be 1324.18 {°}C and 1491.61 {°}C with the corresponding combined standard uncertainty of 0.44 {°}C and 0.31 {°}C for Co-C and Pd-C, respectively, taking into account of the differences of two different types of furnaces used. The determined ITS-90 temperatures are also compared with that of INRIM cells obtained using the same reference radiation thermometer and the same furnaces with the same settings during a previous bilateral comparison exercise (Battuello et al. in Int J Thermophys 35:535-546, 2014). The agreements are within k=1 uncertainty for Co-C cell and k = 2 uncertainty for Pd-C cell. Shapes of the plateaus of NMC cells and INRIM cells are compared too and furnace effects are analyzed as well. The melting curves of the Co-C and Pd-C cells realized in the single-zone furnace are also measured by a Pt/Pd thermocouple, and the preliminary results are presented as well.

  9. Investigating Microbial Habitats in Hydrothermal Chimneys using Ti-Thermocouple Arrays: Microbial Diversity

    Science.gov (United States)

    Pagé, A.; Tivey, M. K.; Stakes, D. S.; Bradley, A. M.; Seewald, J. S.; Wheat, C. G.; Reysenbach, A.

    2004-12-01

    In order to examine the changes that occur in the microbial community composition as a deep-sea hydrothermal vent chimney develops, we deployed Ti-thermocouple arrays over high temperature vents at two active sites of the Guaymas Basin Southern Trough. Chimney material that precipitated around the arrays was recovered after 4 and 72 days. Chimney material that precipitated prior to deployment of the arrays was also recovered at one of the sites (Busted Shroom). Culture-independent analysis based on the small subunit rRNA sequence (cloning and DGGE) was used to determine the microbial diversity associated with subsamples of each chimney. The original Busted Shroom chimney (BSO) was dominated by members of the Crenarchaeota Marine Group I, a group of cosmopolitan marine Archaea, ɛ -Proteobacteria, and γ -Proteobacteria, two divisions of Bacteria that are common to deep-sea vents. The 4 days old Busted Shroom chimney (BSD1) was dominated by members of the Methanocaldococcaceae, hyperthermophilic methanogens, and the 72 days old chimney (BSD2) by members of the Methanosarcinaceae, mesophilic and thermophilic methanogens. At the second site, Toadstool, the 72 days old chimney material that had precipitated around the array (TS) revealed the dominance of sequences from uncultured marine Archaea, the DHVE group I and II, and from the ɛ -Proteobacteria. Additionally, sequences belonging to the Methanocaldococcaceae and Desulfurococcaceae were recovered next to thermocouples that were at temperatures of 109° C (at Busted Shroom) and 116° C (at Toadstool), respectively. These temperatures are higher than the upper limit for growth of cultured representatives from each family.

  10. Comparison of two surface temperature measurement using thermocouples and infrared camera

    Directory of Open Access Journals (Sweden)

    Michalski Dariusz

    2017-01-01

    Full Text Available This paper compares two methods applied to measure surface temperatures at an experimental setup designed to analyse flow boiling heat transfer. The temperature measurements were performed in two parallel rectangular minichannels, both 1.7 mm deep, 16 mm wide and 180 mm long. The heating element for the fluid flowing in each minichannel was a thin foil made of Haynes-230. The two measurement methods employed to determine the surface temperature of the foil were: the contact method, which involved mounting thermocouples at several points in one minichannel, and the contactless method to study the other minichannel, where the results were provided with an infrared camera. Calculations were necessary to compare the temperature results. Two sets of measurement data obtained for different values of the heat flux were analysed using the basic statistical methods, the method error and the method accuracy. The experimental error and the method accuracy were taken into account. The comparative analysis showed that although the values and distributions of the surface temperatures obtained with the two methods were similar but both methods had certain limitations.

  11. Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

    Directory of Open Access Journals (Sweden)

    Abdil Kus

    2015-01-01

    Full Text Available In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  12. Thermocouple and infrared sensor-based measurement of temperature distribution in metal cutting.

    Science.gov (United States)

    Kus, Abdil; Isik, Yahya; Cakir, M Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-12

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  13. Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

    Science.gov (United States)

    Kus, Abdil; Isik, Yahya; Cakir, M. Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-01

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining. PMID:25587976

  14. External attachment of titanium sheathed thermocouples to zirconium nuclear fuel rods for the loss-of-fluid-test (LOFT) Reactor

    International Nuclear Information System (INIS)

    Welty, R.K.

    1980-01-01

    A welding process to attach titanium sheathed thermocouples to the outside of the zircaloy clad fuel rods has been developed. A laser beam was selected as the optimum welding process because of the extremely high energy input per unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. Irradiation tests showed no degradation of thermocouples or weld structure. Fast thermal cycle and heater rod blowdown reflood tests were made to subject the weldments to high temperatures, high pressure steam, and fast water quench cycles. From the behavior of these tests, it was concluded that the attachment welds would survive a series of reactor safety tests. 2 refs

  15. Nuclear Power Plant Thermocouple Sensor-Fault Detection and Classification Using Deep Learning and Generalized Likelihood Ratio Test

    Science.gov (United States)

    Mandal, Shyamapada; Santhi, B.; Sridhar, S.; Vinolia, K.; Swaminathan, P.

    2017-06-01

    In this paper, an online fault detection and classification method is proposed for thermocouples used in nuclear power plants. In the proposed method, the fault data are detected by the classification method, which classifies the fault data from the normal data. Deep belief network (DBN), a technique for deep learning, is applied to classify the fault data. The DBN has a multilayer feature extraction scheme, which is highly sensitive to a small variation of data. Since the classification method is unable to detect the faulty sensor; therefore, a technique is proposed to identify the faulty sensor from the fault data. Finally, the composite statistical hypothesis test, namely generalized likelihood ratio test, is applied to compute the fault pattern of the faulty sensor signal based on the magnitude of the fault. The performance of the proposed method is validated by field data obtained from thermocouple sensors of the fast breeder test reactor.

  16. Description of an identification method of thermocouple time constant based on application of recursive numerical filtering to temperature fluctuation

    International Nuclear Information System (INIS)

    Bernardin, B.; Le Guillou, G.; Parcy, JP.

    1981-04-01

    Usual spectral methods, based on temperature fluctuation analysis, aiming at thermocouple time constant identification are using an equipment too much sophisticated for on-line application. It is shown that numerical filtering is optimal for this application, the equipment is simpler than for spectral methods and less samples of signals are needed for the same accuracy. The method is described and a parametric study was performed using a temperature noise simulator [fr

  17. New fixed-point mini-cell to investigate thermocouple drift in a high-temperature environment under neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M.; Vlahovic, L.; Rondinella, V.V. [European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, D-76125 Karlsruhe, (Germany); Sadli, M.; Failleau, G. [Laboratoire Commun de Metrologie, LNE-Cnam, Saint-Denis, (France); Fuetterer, M.; Lapetite, J.M. [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten, (Netherlands); Fourrez, S. [Thermocoax, 8 rue du pre neuf, F-61100 St Georges des Groseillers, (France)

    2015-07-01

    Temperature measurements in the nuclear field require a high degree of reliability and accuracy. Despite their sheathed form, thermocouples subjected to nuclear radiations undergo changes due to radiation damage and transmutation that lead to significant EMF drift during long-term fuel irradiation experiment. For the purpose of a High Temperature Reactor fuel irradiation to take place in the High Flux Reactor Petten, a dedicated fixed-point cell was jointly developed by LNE-Cnam and JRC-IET. The developed cell to be housed in the irradiation rig was tailor made to quantify the thermocouple drift during the irradiation (about two year duration) and withstand high temperature (in the range 950 deg. C - 1100 deg. C) in the presence of contaminated helium in a graphite environment. Considering the different levels of temperature achieved in the irradiation facility and the large palette of thermocouple types aimed at surveying the HTR fuel pebble during the qualification test both copper (1084.62 deg. C) and gold (1064.18 deg. C) fixed-point materials were considered. The aim of this paper is to first describe the fixed-point mini-cell designed to be embedded in the reactor rig and to discuss the preliminary results achieved during some out of pile tests as much as some robustness tests representative of the reactor scram scenarios. (authors)

  18. Use of indexed sensitivity factors in the analysis of nickel and iron based alloys: study of the decalibration of sheathed Chromel/Alumel thermocouples

    International Nuclear Information System (INIS)

    Christie, W.H.

    1978-01-01

    Sheathed Chromel versus Alumel thermocouples decalibrate when exposed to temperatures in excess of 1100 0 C. Thermocouples sheathed in Inconel-600 and type 304 stainless steel were studied in this work. Quantified SIMS data showed that the observed decalibrations were due to significant alterations that took place in the Chromel and Alumel thermoelements. The amount of alteration was different for each thermocouple and was influenced by the particular sheath material used in the thermocouple construction. Relative sensitivity factors, indexed by a matrix ion species ratio, were used to quantify SIMS data for three nickel-based alloys, Chromel, Alumel, and Inconel-600, and an iron-based alloy, type 304 stainless steel. Oxygen pressure >2 x 10 -6 torr in the sputtering region gave enhanced sensitivity and superior quantitative results as compared to data obtained at instrumental residual pressure

  19. The influence of lead temperature on the accuracy of various stainless-steel sheathed, mineral-inulated nickel-chromium/nickel aluminium thermocouples

    International Nuclear Information System (INIS)

    Burnett, P.; Burns, J.S.

    1977-10-01

    Samples of three types of stainless steel sheathed MI thermocouples, such as are currently used in fire and furnace tests of transport flasks, have been subjected to high lead temperatures whilst the thermojunctions were kept at a constant low temperature. Both the lead temperature and the length of lead at temperature have been varied. As the lead temperature rises from ambient to a selected value, the emf output from the thermocouple initially decreases and then increases, taking up a final value dependent on the particular conditions. Below a threshold lead temperature, no significant steady state error occurs and the negative transient is generally negligible. Each thermocouple has its own threshold temperature, the lowest found being about 600 0 C, although the average lies at about 750 0 C. Above the threshold lead temperature, the thermal emf can be in error by the equivalent of more than 100 0 C, the highest error found being nearly 230 0 C at a temperature 250 0 C above threshold. The same thermocouple showed a negative transient of 13 0 C 3 minutes after start of heating to 890 0 C. It is probable that the steady state error arises because of the degradation of the thermocouple mineral insulation at elevated temperatures and recommendations are made on the use of such thermocouples in fire and furnace tests. The cause of the initial negative transient error has not been identified, but ways of minimising any resultant errors are suggested. (author)

  20. Uniformity index measurement technology using thermocouples to improve performance in urea-selective catalytic reduction systems

    Science.gov (United States)

    Park, Sangki; Oh, Jungmo

    2018-05-01

    The current commonly used nitrogen oxides (NOx) emission reduction techniques employ hydrocarbons (HCs), urea solutions, and exhaust gas emissions as the reductants. Two of the primary denitrification NOx (DeNOx) catalyst systems are the HC-lean NOx trap (HC-LNT) catalyst and urea-selective catalytic reduction (urea-SCR) catalyst. The secondary injection method depends on the type of injector, injection pressure, atomization, and spraying technique. In addition, the catalyst reaction efficiency is directly affected by the distribution of injectors; hence, the uniformity index (UI) of the reductant is very important and is the basis for system optimization. The UI of the reductant is an indicator of the NOx conversion efficiency (NCE), and good UI values can reduce the need for a catalyst. Therefore, improving the UI can reduce the cost of producing a catalytic converter, which are expensive due to the high prices of the precious metals contained therein. Accordingly, measurement of the UI is an important process in the development of catalytic systems. Two of the commonly used methods for measuring the reductant UI are (i) measuring the exhaust emissions at many points located upstream/downstream of the catalytic converter and (ii) acquisition of a reductant distribution image on a section of the exhaust pipe upstream of the catalytic converter. The purpose of this study is to develop a system and measurement algorithms to measure the exothermic response distribution in the exhaust gas as the reductant passes through the catalytic converter of the SCR catalyst system using a set of thermocouples downstream of the SCR catalyst. The system is used to measure the reductant UI, which is applied in real-time to the actual SCR system, and the results are compared for various types of mixtures for various engine operating conditions and mixer types in terms of NCE.

  1. Long Hole Film Cooling Dataset for CFD Development . Part 1; Infrared Thermography and Thermocouple Surveys

    Science.gov (United States)

    Shyam, Vikram; Thurman, Douglas; Poinsatte, Phillip; Ameri, Ali; Eichele, Peter; Knight, James

    2013-01-01

    An experiment investigating flow and heat transfer of long (length to diameter ratio of 18) cylindrical film cooling holes has been completed. In this paper, the thermal field in the flow and on the surface of the film cooled flat plate is presented for nominal freestream turbulence intensities of 1.5 and 8 percent. The holes are inclined at 30deg above the downstream direction, injecting chilled air of density ratio 1.0 onto the surface of a flat plate. The diameter of the hole is 0.75 in. (0.01905 m) with center to center spacing (pitch) of 3 hole diameters. Coolant was injected into the mainstream flow at nominal blowing ratios of 0.5, 1.0, 1.5, and 2.0. The Reynolds number of the freestream was approximately 11,000 based on hole diameter. Thermocouple surveys were used to characterize the thermal field. Infrared thermography was used to determine the adiabatic film effectiveness on the plate. Hotwire anemometry was used to provide flowfield physics and turbulence measurements. The results are compared to existing data in the literature. The aim of this work is to produce a benchmark dataset for Computational Fluid Dynamics (CFD) development to eliminate the effects of hole length to diameter ratio and to improve resolution in the near-hole region. In this report, a Time-Filtered Navier Stokes (TFNS), also known as Partially Resolved Navier Stokes (PRNS), method that was implemented in the Glenn-HT code is used to model coolant-mainstream interaction. This method is a high fidelity unsteady method that aims to represent large scale flow features and mixing more accurately.

  2. Thermocouple psychrometer measurements of in situ water potential changes in heated welded tuff

    International Nuclear Information System (INIS)

    Mao, Nai-hsien; Wang, H.F.

    1991-05-01

    Ten thermocouple psychrometers (TCPs) to measure water potential (WP) were installed in three holes in G-Tunnel at the Nevada Test Site as part of the Prototype Engineered Barrier System Field Tests. These integrated tests measured several parameters as a function of location and time within a few meters of a heater emplaced in welded tuff. The primary goal of the TCP experiment was to find out whether the combination of laboratory calibration and field use of the TCP can provide useful data for determining the change of moisture condition in the field. We calibrated the TCPs in NaCl solutions up to 80 degree C(176 degree F) in the laboratory. In two holes, we used rubber sleeves and packers to house TCPs, and in the third hole, we used foam. All three holes were grouted behind the TCP assemblages. Field results of the heater test showed that small temperature gradients were present for all measurements. Nevertheless, the WP calibration made the necessary correction for the nonisothermal condition. A drying and re-wetting cycle peaked at about day 140 with a WP of -65 bar in borehole P3, located below the heater. A similar cycle but reduced in scale was found at about day 175 with a WP of -45 bar in borehole P2, above the heater. This difference in drying behavior above and below the heater was also observed from neutron data and was explained as a gravity effect. As temperatures increased, the evaporation rate of pore water increased, In unfractured rock, the gas-phase flow was primarily outward. Water condensed above the heater would drain back to keep the boiling region wet, but water condensed below the heater would drain away from the boiling region. This conceptual model explained both the time and magnitude differences for data from holes above and below the heater. 7 refs., 14 figs., 2 tabs

  3. Experimental measurement of the interfacial heat transfer coefficients of subcooled flow boiling using micro-thermocouple and double directional images

    International Nuclear Information System (INIS)

    Seong-Jin Kim; Goon-Cherl Park

    2005-01-01

    Full text of publication follows: Models or correlations for phase interface are needed to analyze the multi-phase flow. Interfacial heat transfer coefficients are important to constitute energy equation of multi-phase flow, specially. In subcooled boiling flow, bubble condensation at the bubble-liquid interface is a major mechanism of heat transfer within bulk subcooled liquid. Bubble collapse rates and temperatures of each phase are needed to determine the interfacial heat transfer coefficient for bubble condensation. Bubble collapse rates were calculated through image processing in single direction, generally. And in case of liquid bulk temperature, which has been obtained by general temperature sensor such as thermocouple, was used. However, multi-directional images are needed to analyze images due to limitations of single directional image processing. Also, temperature sensor, which has a fast response time, must be used to obtain more accurate interfacial heat transfer coefficient. Low pressure subcooled water flow experiments using micro-thermocouple and double directional image processing with mirrors were conducted to investigate bubble condensation phenomena and to modify interfacial heat transfer correlation. Experiments were performed in a vertical subcooled boiling flow of a rectangular channel. Bubble condensing traces with respect to time were recorded by high speed camera in double direction and bubble collapse rates were calculated by processing recorded digital images. Temperatures were measured by micro-thermocouple, which is a K-type with a 12.7 μm diameter. The liquid temperature was estimated by the developed algorithm to discriminate phases and find each phase temperature in the measured temperature including both liquid and bubble temperature. The interfacial heat transfer coefficient for bubble condensation was calculated from the bubble collapse rates and the estimated liquid temperature, and its correlation was modified. The modified

  4. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

    International Nuclear Information System (INIS)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal

    2016-01-01

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  5. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method).

    Science.gov (United States)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal

    2016-06-01

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  6. Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

    Energy Technology Data Exchange (ETDEWEB)

    Bontempi, Alexia; Nguyen, Tran Phong; Salut, Roland; Thiery, Laurent; Teyssieux, Damien; Vairac, Pascal [FEMTO-ST Institute UMR 6174, Université de Franche-Comté, CNRS, ENSMM, UTBM, 15B Avenue des Montboucons, F-25030 Besançon (France)

    2016-06-15

    A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

  7. Study of Thermocurrents in ILC cavities via measurements of the Seebeck Effect in niobium, titanium, and stainless steel thermocouples

    Energy Technology Data Exchange (ETDEWEB)

    Cooley, Victoria [Univ. of Wisconsin, Madison, WI (United States)

    2014-01-01

    The goals of Fermilab’s Superconductivity and Radio Frequency Development Department are to engineer, fabricate, and improve superconducting radio frequency (SCRF) cavities in the interest of advancing accelerator technology. Improvement includes exploring possible limitations on cavity performance and mitigating such impediments. This report focuses on investigating and measuring the Seebeck Effect observed in cavity constituents titanium, niobium, and stainless steel arranged in thermocouples. These junctions exist between cavities, helium jackets, and bellows, and their connection can produce a loop of electrical current and magnetic flux spontaneously during cooling. The experimental procedure and results are described and analyzed. Implications relating the results to cavity performance are discussed.

  8. Attachment of lead wires to thin film thermocouples mounted on high temperature materials using the parallel gap welding process

    Science.gov (United States)

    Holanda, Raymond; Kim, Walter S.; Pencil, Eric; Groth, Mary; Danzey, Gerald A.

    1990-01-01

    Parallel gap resistance welding was used to attach lead wires to sputtered thin film sensors. Ranges of optimum welding parameters to produce an acceptable weld were determined. The thin film sensors were Pt13Rh/Pt thermocouples; they were mounted on substrates of MCrAlY-coated superalloys, aluminum oxide, silicon carbide and silicon nitride. The entire sensor system is designed to be used on aircraft engine parts. These sensor systems, including the thin-film-to-lead-wire connectors, were tested to 1000 C.

  9. Investigation of pool boiling dynamics on a rectangular heater using nano-thermocouples: is it chaotic or stochastic?

    Energy Technology Data Exchange (ETDEWEB)

    Sathyamurthi, Vijaykumar; Banerjee, Debjyoti [Texas A and M University, College Station, TX (United States). Dept. of Mechanical Engineering], e-mail: dbanerjee@tamu.edu

    2009-07-01

    The non-linear dynamical model of pool boiling on a horizontal rectangular heater is assessed from experimental results in this study. Pool boiling experiments are conducted over a horizontal rectangular silicon substrate measuring 63 mm x 35 mm with PF-5060 as the test fluid. Novel nano-thermocouples, micro-machined in-situ on the silicon substrate are used to measure the surface temperature fluctuations for steady state pool boiling. The acquisition frequency for temperature data from the nano-thermocouples is 1 k Hz. The surface temperature fluctuations are analyzed using the TISEAN{sup c} package. A time-delay embedding is employed to generate higher dimensional phase-space vectors from the temperature time series record. The optimal delay is determined from the first minimum of the mutual information function. Techniques such as recurrence plots, and false nearest neighbors tests are employed to assess the presence of deterministic chaotic dynamics. Chaos quantifiers such as correlation dimensions are found for various pool boiling regimes using the raw data as well as noise-reduced data. Additionally, pseudo-phase spaces are used to reconstruct the 'attractors'. The results after non-linear noise reduction shows definitive presence of low-dimensional (d {<=} 7) chaos in fully developed nucleate boiling, at critical heat flux and in film boiling. (author)

  10. Investigation of pool boiling dynamics on a rectangular heater using nano-thermocouples: is it chaotic or stochastic?

    International Nuclear Information System (INIS)

    Sathyamurthi, Vijaykumar; Banerjee, Debjyoti

    2009-01-01

    The non-linear dynamical model of pool boiling on a horizontal rectangular heater is assessed from experimental results in this study. Pool boiling experiments are conducted over a horizontal rectangular silicon substrate measuring 63 mm x 35 mm with PF-5060 as the test fluid. Novel nano-thermocouples, micro-machined in-situ on the silicon substrate are used to measure the surface temperature fluctuations for steady state pool boiling. The acquisition frequency for temperature data from the nano-thermocouples is 1 k Hz. The surface temperature fluctuations are analyzed using the TISEAN c package. A time-delay embedding is employed to generate higher dimensional phase-space vectors from the temperature time series record. The optimal delay is determined from the first minimum of the mutual information function. Techniques such as recurrence plots, and false nearest neighbors tests are employed to assess the presence of deterministic chaotic dynamics. Chaos quantifiers such as correlation dimensions are found for various pool boiling regimes using the raw data as well as noise-reduced data. Additionally, pseudo-phase spaces are used to reconstruct the 'attractors'. The results after non-linear noise reduction shows definitive presence of low-dimensional (d ≤ 7) chaos in fully developed nucleate boiling, at critical heat flux and in film boiling. (author)

  11. Internal attachment of laser beam welded stainless steel sheathed thermocouples into stainless steel upper end caps in nuclear fuel rods for the LOFT Reactor

    International Nuclear Information System (INIS)

    Welty, R.K.; Reid, R.D.

    1980-01-01

    The Exxon Nuclear Company, Inc., acting as a subcontractor to EG and G Idaho Inc., Idaho National Engineering Laboratory, Idaho Falls, Idaho, conducted a laser beam welding study to attach internal stainless steel thermocouples into stainless steel upper end caps in nuclear fuel rods. The objective of this study was to determine the feasibility of laser welding a single 0.063 inch diameter stainless steel (304) sheathed thermocouple into a stainless steel (316) upper end cap for nuclear fuel rods. A laser beam was selected because of the extremely high energy input in unit volume that can be achieved allowing local fusion of a small area irrespective of the difference in material thickness to be joined. A special weld fixture was designed and fabricated to hold the end cap and the thermocouple with angular and rotational adjustment under the laser beam. A commercial pulsed laser and energy control system was used to make the welds

  12. Manifestations of nonlinearity in fuel center thermocouple steady-state and transient data: implications for data analysis

    International Nuclear Information System (INIS)

    Lanning, D.D.; Barnes, B.O.; Williford, R.E.

    1979-01-01

    The interpretation and verification of fuel centerline thermocouple data are analyzed. Two new concepts are discussed along with their application to in-reactor data from IFA-432, a heavily instrumented six-rod Halden reactor test assembly sponsored by the Nuclear Regulatory Commission. The main ideas presented in this report are that: it is more useful to plot resistance versus power than simply to plot temperature versus power; and the response of the centerline temperature to a linear power decrease is correlated to the rod's current resistance-vs-power behavior. Thus, the resistance-vs-power measurement can be verified by performing a linear power decrease and by plotting the temperature response

  13. Home-made temperature monitoring system from four-channel K-type thermocouples via internet of thing technology platform

    Science.gov (United States)

    Detmod, Thitaporn; Özmen, Yiǧiter; Songkaitiwong, Kittiphot; Saenyot, Khanuengchat; Locharoenrat, Kitsakorn; Lekchaum, Sarai

    2018-06-01

    This paper is aimed to design and construct the home-made temperature monitoring system from four-channel K-type thermocouples in order to improve the temperature measurement based on standard evaluation measurements guidance. The temperature monitoring system was capable to record the temperature on SD card and to display the realtime temperature on Internet of Thing Technology platform. The temperature monitoring system was tested in terms of the temperature measurement accuracy and delay response time. It was found that a standard deviation was acceptable as compared to the Instrument Society of America. The response time of the microcontroller to SD card was 2 sec faster than that of the microcontroller to Thingspeak.

  14. The Combined Use of a Gas-Controlled Heat Pipe and a Copper Point to Improve the Calibration of Thermocouples up to 1100 ˚C

    Science.gov (United States)

    Astrua, M.; Iacomini, L.; Battuello, M.

    2008-10-01

    The calibration of platinum-based thermocouples from 420 °C to 1,100 ˚C is currently carried out at INRIM making use of two different apparatus: for temperatures below 930 ˚C, a potassium gas-controlled heat pipe (GCHP) is used, whereas a metal-block furnace is adopted for higher temperatures. The standard uncertainty of the reference temperature obtained in the lower temperature range is almost one order of magnitude better than in the higher temperature range. A sealed copper cell was investigated to see if it could be used to calibrate thermocouples above 930 ˚C with a lower uncertainty than our current procedures allowed. The cell was characterized with Type S and Pt/Pd thermocouples and with an HTPRT. The freezing plateaux were flat within 0.01 ˚C and lasted up to 1 h with a repeatability of 0.02 ˚C. The temperature of the cell was determined with a standard uncertainty of 0.04 ˚C. Hence, the copper cell was found to be superior to the comparator furnace for the calibration of platinum-based thermocouples because of the significant decrease in the uncertainty that it provides. An analysis was also carried out on the calibration of Pt/Pd thermocouples, and it was found that the combined use of the potassium GCHP and the Cu fixed-point cell is adequate to exploit the potential of these sensors in the range from 420 °C to 1,084 °C. A comparison with a fixed-point calibration was also made which gave rise to agreement within 0.07 ˚C between the two approaches.

  15. A Grid of Fine Wire Thermocouples to Study the Spatial Coherence of Turbulence within Katabatic Flow through a Vineyard Canopy

    Science.gov (United States)

    Everard, K.; Christen, A.; Sturman, A.; Skaloud, P.

    2016-12-01

    Knowledge of the dynamics and thermodynamics of katabatic flow is relevant in vineyards, where grapevines are sensitive to temperature changes (frost protection and cooling). Basic understanding of the occurrence and evolution of, and turbulence within, katabatic flow is well known over bare slopes. However, little work has been completed to extend this understanding to mid-sized canopies and how the presence of a canopy affects the turbulent exchange of momentum and heat within the flow. Measurements were carried out over a 6° vineyard slope near Oliver, BC, Canada in the Okanagan Valley between July 5 and July 22, 2016. The set-up consisted of an array of five vertically arranged CSAT 3D (Campbell Scientific, Inc.) ultrasonic anemometers at z = 0.45 m, 0.90 m, 1.49 m, 2.34 m, and 4.73 m above ground level (AGL), and a 2-D grid of 40 Type-E (copper-constantan) fine-wire thermocouples (FWTC) arranged at the same heights as the CSAT 3D array on 8 masts extending in the upslope (flow) direction at locations x = 0.0 m (CSAT 3D tower), 0.5 m, 1.0 m, 2.0 m, 4.0 m, 8.0 m, 16.0 m, and 32.0 m. The FWTC array formed a sheet of 40 sampling points in the upslope-vertical plane. The height of the grapevine canopy (h) was approximately 2 m AGL, and rows were aligned along the local slope direction with a row spacing of 2.45 m. CSAT-3s were sampled at 60 Hz with 20 Hz data recording, the FWTCs were sampled at 2 Hz, all synchronized by a data logger. Katabatic flow was observed on several nights during the campaign, with a wind speed maximum located within the canopy. This contribution will focus on the measurement techniques, combining ultrasonic anemometer data with the spatially synchronized FWTC array using image process techniques. We identify the dynamics and structure of the katabatic flow, relevant for heat exchange, using the spatial coherence of the temperature field given by the FWTC array. Improved knowledge of the vertical structure and the dynamics of katabatic

  16. n⁺ GaAs/AuGeNi-Au Thermocouple-Type RF MEMS Power Sensors Based on Dual Thermal Flow Paths in GaAs MMIC.

    Science.gov (United States)

    Zhang, Zhiqiang; Liao, Xiaoping

    2017-06-17

    To achieve radio frequency (RF) power detection, gain control, and circuit protection, this paper presents n⁺ GaAs/AuGeNi-Au thermocouple-type RF microelectromechanical system (MEMS) power sensors based on dual thermal flow paths. The sensors utilize a conversion principle of RF power-heat-voltage, where a thermovoltage is obtained as the RF power changes. To improve the heat transfer efficiency and the sensitivity, structures of two heat conduction paths are designed: one in which a thermal slug of Au is placed between two load resistors and hot junctions of the thermocouples, and one in which a back cavity is fabricated by the MEMS technology to form a substrate membrane underneath the resistors and the hot junctions. The improved sensors were fabricated by a GaAs monolithic microwave integrated circuit (MMIC) process. Experiments show that these sensors have reflection losses of less than -17 dB up to 12 GHz. At 1, 5, and 10 GHz, measured sensitivities are about 63.45, 53.97, and 44.14 µ V/mW for the sensor with the thermal slug, and about 111.03, 94.79, and 79.04 µ V/mW for the sensor with the thermal slug and the back cavity, respectively.

  17. n+ GaAs/AuGeNi-Au Thermocouple-Type RF MEMS Power Sensors Based on Dual Thermal Flow Paths in GaAs MMIC

    Directory of Open Access Journals (Sweden)

    Zhiqiang Zhang

    2017-06-01

    Full Text Available To achieve radio frequency (RF power detection, gain control, and circuit protection, this paper presents n+ GaAs/AuGeNi-Au thermocouple-type RF microelectromechanical system (MEMS power sensors based on dual thermal flow paths. The sensors utilize a conversion principle of RF power-heat-voltage, where a thermovoltage is obtained as the RF power changes. To improve the heat transfer efficiency and the sensitivity, structures of two heat conduction paths are designed: one in which a thermal slug of Au is placed between two load resistors and hot junctions of the thermocouples, and one in which a back cavity is fabricated by the MEMS technology to form a substrate membrane underneath the resistors and the hot junctions. The improved sensors were fabricated by a GaAs monolithic microwave integrated circuit (MMIC process. Experiments show that these sensors have reflection losses of less than −17 dB up to 12 GHz. At 1, 5, and 10 GHz, measured sensitivities are about 63.45, 53.97, and 44.14 µV/mW for the sensor with the thermal slug, and about 111.03, 94.79, and 79.04 µV/mW for the sensor with the thermal slug and the back cavity, respectively.

  18. Accounting for the inertia of the thermocouples' measurements by modelling of a NPP Kalinin-3 transient with the coupled system code ATHLET-BIPR-VVER

    International Nuclear Information System (INIS)

    Nikonov, S.; Velkov, K.

    2008-01-01

    The ATHLET-BIPR-VVER coupled system code is applied for performing of safety analysis for different WWER reactors. During the last years its validation matrix is continuously being enlarged. The measurements performed during the commissioning phase of NPP Kalinin Unit 3 for the transient 'Switching-off of one Main Circulation Pump at nominal power' are very well documented and have a variety of recorded integral and local thermo-hydraulic and neutron-physic parameters including the measurements' errors. This data is being used for further validation of the coupled code system ATHLET-BIPR-VVER. In the paper are discussed the problems and our solutions by the correct interpretation of the measured thermocouples' records at NPP Kalinin-3 and the comparison with the predicted results by the coupled thermal-hydraulic/neutron-kinetic code ATHLET-BIPR-VVER. Of primary importance by such comparisons is the correct accounting of the fluid mixing process that take place in the surrounding of the measuring sensors and also the consideration of the time delay (inertia term) of the measuring devices. On the bases of previous experience and many simulations of the defined transient a method is discussed and proposed to consider correctly the inertia term of the thermocouples' measurements. The new modelling is implemented in the coupled system code ATHLET-BIPR-VVER for further validation. (Author)

  19. Study for on-line system to identify inadvertent control rod drops in PWR reactors using ex-core detector and thermocouple measures

    International Nuclear Information System (INIS)

    Souza, Thiago J.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C.

    2015-01-01

    Accidental control rod drops event in PWR reactors leads to an unsafe operating condition. It is important to quickly identify the rod to minimize undesirable effects in such a scenario. In this event, there is a distortion in the power distribution and temperature in the reactor core. The goal of this study is to develop an on-line model to identify the inadvertent control rod dropped in PWR reactor. The proposed model is based on physical correlations and pattern recognition of ex-core detector responses and thermocouples measures. The results of the study demonstrated the feasibility of an on-line system, contributing to safer operation conditions and preventing undesirable effects, as its shutdown. (author)

  20. Study for on-line system to identify inadvertent control rod drops in PWR reactors using ex-core detector and thermocouple measures

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Thiago J.; Medeiros, Jose A.C.C.; Goncalves, Alessandro C., E-mail: tsouza@nuclear.ufrj.br, E-mail: canedo@lmp.ufrj.br, E-mail: alessandro@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2015-07-01

    Accidental control rod drops event in PWR reactors leads to an unsafe operating condition. It is important to quickly identify the rod to minimize undesirable effects in such a scenario. In this event, there is a distortion in the power distribution and temperature in the reactor core. The goal of this study is to develop an on-line model to identify the inadvertent control rod dropped in PWR reactor. The proposed model is based on physical correlations and pattern recognition of ex-core detector responses and thermocouples measures. The results of the study demonstrated the feasibility of an on-line system, contributing to safer operation conditions and preventing undesirable effects, as its shutdown. (author)

  1. Thin film thermocouples for in situ membrane electrode assembly temperature measurements in a polybenzimidazole-based high temperature proton exchange membrane unit cell

    DEFF Research Database (Denmark)

    Ali, Syed Talat; Lebæk, Jesper; Nielsen, Lars Pleth

    2010-01-01

    m thick layer of TFTCs on 75 mu m thick Kapton foil. The Kapton foil was treated with in situ argon plasma etching to improve the adhesion between TFTCs and the Kapton substrate. The TFTCs were covered with a 7 mu m liquid Kapton layer using spin coating technique to protect them from environmental......This paper presents Type-T thin film thermocouples (TFTCs) fabricated on Kapton (polyimide) substrate for measuring the internal temperature of PBI(polybenzimidazole)-based high temperature proton exchange membrane fuel cell (HT-PEMFC). Magnetron sputtering technique was employed to deposit a 2 mu...... degradation. This Kapton foil with deposited TFTCs was used as sealing inside a PBI (polybenzimidazole)-based single cell test rig, which enabled measurements of in situ temperature variations of the working fuel cell MEA. The performance of the TFTCs was promising with minimal interference to the operation...

  2. Construção e avaliação de psicrômetro aspirado de termopar Construction and evaluation of an aspirated thermocouple psychrometer

    Directory of Open Access Journals (Sweden)

    Fábio Ricardo Marin

    2001-12-01

    Full Text Available Construiu-se um psicrômetro de termopar aspirado, de baixo custo e fácil utilização em sistemas automáticos de aquisição de dados, utilizando-se tubos de PVC. A aspiração foi feita por ventiladores utilizados em microcomputadores e as temperaturas foram determinadas com junções de termopar de cobre-constantan. Para umidecimento do bulbo, utilizou-se um cordão de algodão. Os resultados da comparação com higrômetro capacitivo Vaisala Inc. e com psicrômetro aspirado tipo Assman mostraram que tanto em ambientes naturais como em controlados, a precisão e a exatidão das medidas foi muito boa, de maneira que o psicrômetro aqui descrito pode ser empregado para determinação da pressão atual de vapor e da umidade relativa sem perda de qualidade dos dados, e também em estudos que levem em conta gradientes de temperatura e umidade específica.The construction of a low cost aspirated thermocouple psychrometer made of PVC tubes is described. The instrument can easily be connected to dataloggers. The aspiration is made by fans used in microcomputers and temperatures measured with cooper-constantan thermocouples. A cotton string was used to make the wet junction. Its perfomance was evaluated in comparison to an Assman aspirated psychrometer and a Vaisala Inc. capacitive higrometer, in natural and controlled environments. The results show a good agreement between measures, allowing air vapour, relative humidity, temperature and specific humidity gradients to be determined using the proposed psychrometer.

  3. Performance of core exit thermocouple for PWR accident management action in vessel top break LOCA simulation experiment at OECD/NEA ROSA project

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Takeda, Takeshi; Nakamura, Hideo

    2009-01-01

    Presented are experiment results of the Large Scale Test Facility (LSTF) conducted at the Japan Atomic Energy Agency (JAEA) with a focus on core exit thermocouple (CET) performance to detect core overheat during a vessel top break loss-of-coolant accident (LOCA) simulation experiment. The CET temperatures are used to start accident management (AM) action to quickly depressurize steam generator (SG) secondary side in case of core temperature excursion. Test 6-1 is first test of the OECD/NEA ROSA Project started in 2005, simulating withdraw of a control rod drive mechanism penetration nozzle at the vessel top head. The break size is equivalent to 1.9% cold leg break. The AM action was initiated when CET temperature rose up to 623K. There was no reflux water fallback onto the CETs during the core heat-up period. The core overheat, however, was detected with a time delay of about 230s. In addition, a large temperature discrepancy was observed between the CETs and the hottest core region. This paper clarifies the reason of time delay and temperature discrepancy between the CETs and heated core during boil-off including three-dimensional steam flows in the core and core exit. The paper discusses applicability of the LSTF CET performance to pressurized water reactor (PWR) conditions and a possibility of alternative indicators for earlier AM action than in Test 6-1 is studied by using symptom-based plant parameters such as a reactor vessel water level detection. (author)

  4. Simulation of a welding process in polyduct pipelines resolved with a finite elements computational model. Comparison with analytical solutions and tests with thermocouples

    International Nuclear Information System (INIS)

    Sanzi, H; Elvira, G; Kloster, M; Asta, E; Zalazar, M

    2006-01-01

    All welding processes induce deformations and thermal tensions, which must be evaluated correctly since they can influence a component's structural integrity. This work determines the distribution of temperatures that develop during a manual welding process with shielded electrodes (SMAW), on the circumference seam of a pipe for use in polyducts. A simplified model of Finite Elements (FEA) using three dimensional solids is proposed for the study. The analysis considers that while the welding process is underway, no heat is lost into the environment, that is, adiabatic conditions are considered, and the transformations produced in the material due to phase changes do not produce modifications in the properties of the supporting or base materials. The results of the simulation are compared with those obtained by recent analytical studies developed by different investigators, such as Nguyen, Ohta, Matsuoka, Suzuki and Taeda, where a continuously moving three dimensional double ellipsoidal source was used. The results are then compared with the experimental results by measuring with thermocouples. This study reveals the sensitivity and the validity of the proposed computer model, and in a second stage optimizes the engineering times for the resolution of a problem like the one presented in order to design the corresponding welding procedure (CW)

  5. A novel approach for fault detection and classification of the thermocouple sensor in Nuclear Power Plant using Singular Value Decomposition and Symbolic Dynamic Filter

    International Nuclear Information System (INIS)

    Mandal, Shyamapada; Santhi, B.; Sridhar, S.; Vinolia, K.; Swaminathan, P.

    2017-01-01

    Highlights: • A novel approach to classify the fault pattern using data-driven methods. • Application of robust reconstruction method (SVD) to identify the faulty sensor. • Analysing fault pattern for plenty of sensors using SDF with less time complexity. • An efficient data-driven model is designed to the false and missed alarms. - Abstract: A mathematical model with two layers is developed using data-driven methods for thermocouple sensor fault detection and classification in Nuclear Power Plants (NPP). The Singular Value Decomposition (SVD) based method is applied to detect the faulty sensor from a data set of all sensors, at the first layer. In the second layer, the Symbolic Dynamic Filter (SDF) is employed to classify the fault pattern. If SVD detects any false fault, it is also re-evaluated by the SDF, i.e., the model has two layers of checking to balance the false alarms. The proposed fault detection and classification method is compared with the Principal Component Analysis. Two case studies are taken from Fast Breeder Test Reactor (FBTR) to prove the efficiency of the proposed method.

  6. The front-end chip of the SuperB SVT detector

    International Nuclear Information System (INIS)

    Giorgi, F.; Comotti, D.; Manghisoni, M.; Re, V.; Traversi, G.; Fabbri, L.; Gabrielli, A.; Pellegrini, G.; Sbarra, C.; Semprini-Cesari, N.; Valentinetti, S.; Villa, M.; Zoccoli, A.; Berra, A.; Lietti, D.; Prest, M.; Bevan, A.; Wilson, F.; Beck, G.; Morris, J.

    2013-01-01

    The asymmetric e + e − collider SuperB is designed to deliver a high luminosity, greater than 10 36 cm −2 s −1 , with moderate beam currents and a reduced center of mass boost with respect to earlier B-Factories. The innermost detector is the Silicon Vertex Tracker which is made of 5 layers of double sided silicon strip sensors plus a layer 0, that can be equipped with short striplets detectors in a first phase of the experiment. In order to achieve an overall track reconstruction efficiency above 98% it is crucial to optimize both analog and digital readout circuits. The readout architecture being developed for the front-end chips will be able to cope with the very high rates expected in the first layer. The digital readout will be optimized to be fully efficient for hit rates up to 2 MHz/strip, including large margins on the maximum expected background rates, but can potentially accommodate higher rates with a proper tuning of the buffer depth. The readout is based on a triggered architecture where each of the 128 strip channel is provided with a dedicated digital buffer. Each buffer collects the digitized charge information by means of a 4-bit TOT, storing it in conjunction with the related time stamp. The depth of buffers was dimensioned considering the expected trigger latency and hit rate including suitable safety margins. Every buffer is connected to a highly parallelized circuit handling the trigger logic, rejecting expired data in the buffers and channeling the parallel stream of triggered hits to the common output of the chip. The presented architecture has been modeled by HDL language and investigated with a Monte Carlo hit generator emulating the analog front-end behavior. The simulations showed that even applying the highest stressing conditions, about 2 MHz per strip, the efficiency of the digital readout remained above 99.8%

  7. Association of PRES with SVT in the presence of pre-eclampsia: a case report

    Directory of Open Access Journals (Sweden)

    Aysin Kısabay

    2016-08-01

    Full Text Available Clinical findings during the postpartum period include headache, seizures, focal neurological deficits, fluctuation in conscious, and visual complaints (blurred vision, reduced visual acuity, visual field defects, and cortical blindness. A 31 years old woman was pregnant at 37th gestational week and evaluated for her findings of headache, nausea, vomiting, seizure, tendency to sleep and hypertension. Cranial magnetic resonance imaging (MRI was found to be consistent with posterior reversible encephalopathy syndrome as well as venous sinus thrombosis. In conclusion, since their treatment are distinct, possibility of presence of both clinical diagnoses should be kept in mind in the case of headache and/or focal deficits and seizure occurring during the post-partum period.

  8. Development of a fuel-rod simulator and small-diameter thermocouples for high-temperature, high-heat-flux tests in the Gas-Cooled Fast Reactor Core Flow Test Loop

    International Nuclear Information System (INIS)

    McCulloch, R.W.; MacPherson, R.E.

    1983-03-01

    The Core Flow Test Loop was constructed to perform many of the safety, core design, and mechanical interaction tests in support of the Gas-Cooled Fast Reactor (GCFR) using electrically heated fuel rod simulators (FRSs). Operation includes many off-normal or postulated accident sequences including transient, high-power, and high-temperature operation. The FRS was developed to survive: (1) hundreds of hours of operation at 200 W/cm 2 , 1000 0 C cladding temperature, and (2) 40 h at 40 W/cm 2 , 1200 0 C cladding temperature. Six 0.5-mm type K sheathed thermocouples were placed inside the FRS cladding to measure steady-state and transient temperatures through clad melting at 1370 0 C

  9. Development of a fuel-rod simulator and small-diameter thermocouples for high-temperature, high-heat-flux tests in the Gas-Cooled Fast Reactor Core Flow Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    McCulloch, R.W.; MacPherson, R.E.

    1983-03-01

    The Core Flow Test Loop was constructed to perform many of the safety, core design, and mechanical interaction tests in support of the Gas-Cooled Fast Reactor (GCFR) using electrically heated fuel rod simulators (FRSs). Operation includes many off-normal or postulated accident sequences including transient, high-power, and high-temperature operation. The FRS was developed to survive: (1) hundreds of hours of operation at 200 W/cm/sup 2/, 1000/sup 0/C cladding temperature, and (2) 40 h at 40 W/cm/sup 2/, 1200/sup 0/C cladding temperature. Six 0.5-mm type K sheathed thermocouples were placed inside the FRS cladding to measure steady-state and transient temperatures through clad melting at 1370/sup 0/C.

  10. Study of a thermocouple with refractory joints

    International Nuclear Information System (INIS)

    Vandsmael, C.

    1977-01-01

    After having discussed the relationship between the transverse profile, the crown of the rolls and the flatness of the strips, it is proposed to determine the profile indirectly from a measurement of crown or flatness. The crown measurement was attempted by means of contactless transducers fixed on two movable frames, placed on both sides of the rolls to be measured. The method was tested in a 4-high stand at C.R.M. Calibrations were also carried out on industrial rolls. The effect of temperature, as well as the nature and state of the industrial roll surface, did not favour the use of this method for applications requiring both precision and reliability. On the contrary, the first industrial measurements of strip flatness have proved more promising. Tests were made at the discharge from the last finishing stand of the wide-strip mill of S.A. SIDMAR by means of an optical method. By triangulation with the aid of lasers and photodiode grids, local undulations were measured, sometimes at the edges and sometimes at the centre of the strip, even when the strip was under tension. These first successes ought to be followed by the construction and operation of a gauge functioning permanently on the mill, within the framework of a new research

  11. Feasibility Study of Thin Film Thermocouple Piles

    Science.gov (United States)

    Sisk, R. C.

    2001-01-01

    Historically, thermopile detectors, generators, and refrigerators based on bulk materials have been used to measure temperature, generate power for spacecraft, and cool sensors for scientific investigations. New potential uses of small, low-power, thin film thermopiles are in the area of microelectromechanical systems since power requirements decrease as electrical and mechanical machines shrink in size. In this research activity, thin film thermopile devices are fabricated utilizing radio frequency sputter coating and photoresist lift-off techniques. Electrical characterizations are performed on two designs in order to investigate the feasibility of generating small amounts of power, utilizing any available waste heat as the energy source.

  12. Latest results of the R and D on CMOS MAPS for the Layer0 of the SuperB SVT

    Energy Technology Data Exchange (ETDEWEB)

    Balestri, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (Italy); Batignani, G. [Università degli Studi di Pisa (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (Italy); Beck, G. [School of Physics and Astronomy Queen Mary, University of London, London E1 4NS (United Kingdom); Bernardelli, A. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (Italy); Berra, A. [Università dell' Insubria, Como (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano Bicocca (Italy); Bettarini, S. [Università degli Studi di Pisa (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (Italy); Bevan, A. [School of Physics and Astronomy Queen Mary, University of London, London E1 4NS (United Kingdom); Bombelli, L. [Politecnico di Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Bosi, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (Italy); Bosisio, L. [Università degli Studi di Trieste (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Trieste (Italy); Casarosa, G., E-mail: giulia.casarosa@pi.infn.it [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (Italy); Ceccanti, M. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (Italy); Cenci, R. [University of Maryland (United States); Citterio, M.; Coelli, S. [Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Comotti, D. [Università degli Studi di Bergamo (Italy); Dalla Betta, G.-F. [Università degli Studi di Trento (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Padova (Italy); Fabbri, L. [Università degli Studi di Bologna (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Bologna (Italy); and others

    2013-12-21

    Physics and high background conditions set very challenging requirements on readout speed, material budget and resolution for the innermost layer of the SuperB Silicon Vertex Tracker operated at the full luminosity. Monolithic Active Pixel Sensors (MAPS) are very appealing in this application since the thin sensitive region allows grinding the substrate to tens of microns. Deep N-Well MAPS, developed in the ST 130 nm CMOS technology, achieved in-pixel sparsification and fast time stamping. Further improvements are being explored with an intense R and D program, including both vertical integration and 2D MAPS with the INMAPS quadruple well. We present the results of the characterization with IR laser, radioactive sources and beam of several chips produced with the 3D (Chartered/Tezzaron) process. We have also studied prototypes exploiting the features of the quadruple well and the high resistivity epitaxial layer of the INMAPS 180 nm process. Promising results from an irradiation campaign with neutrons on small matrices and other test-structures, as well as the response of the sensors to high energy charged tracks are presented.

  13. De zichtbaarheid van wegmarkeringen op natte wegen : een aanvullende literatuurstudie ten behoeve van de SCI/SVT-verkgroep E9 "Zichtbaarheid van megmarkeringen op natte wegdekken.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1985-01-01

    Road markings, notably lane markers, are often only poorly visible when the road is wet. This is particularly a problem at night on unlit roads. In 1978 a literature report was published on this matter. See PB 14153: A new literature report, mainly from the literature after 1978 to 1985, is

  14. 'Passive fire protection in nuclear power plants' - German technologies of the company svt Brandschutz in future as well in Korean NPPs? -

    International Nuclear Information System (INIS)

    Bremer, Joerg; Kim, Duill; Wendt, Ruediger

    2002-01-01

    Fires in NPPs are unfortunately not avoidable and to consider during the planning and operation period of the plants. The multitude of combustible materials which are used especially cables, oils and other building materials describe a potential source of danger. In Germany recently a new planning guideline for the fire protection field in NPPs has been adopted: the nuclear guideline KTA 1401. This document certainly is one of the most progressive guidelines for the fire protection field and has united · structural engineering elements of fire protection · electrotechnical and machine components · as well as questions of fire alarm and organisation measures. Passive and active fire protection measures are explained and layed down in their complexity within this document. Our group of companies has realised quit a lot of fire protection projects in Europe during the last years, especially within retrofitting measures for NPPs in Germany, Switzerland, Russia, the Ukraine and Lithuania, the Czech and Slovak Republic as well as within decommissioning projects of NPPs. We have carried out international fire protection projects of the EBRD, London, and within the framework of TACIS projects of the European Commission, i. a. linked with the working out of fire protection analyses for NPPs realised in close co-operation with the Germanischer Lloyd, Hamburg. We especially have wide experiences in improving the fire protection of cable installations where a 100% separation of the different safety systems is not any longer possible

  15. High Speed Surface Thermocouples Interface to Wireless Transmitters

    Science.gov (United States)

    2017-03-15

    above engines , or virtually anywhere manufacturers. Electric power plants Inside the mechanisms producing the power Kiln manufacturers, artists...ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) US Army Tank- automotive Research...Development & Engineering Center TARDEC Warren , Michigan 48397-5000 • 11 . SPONSOR/MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION/AVAILABILITY

  16. The effects of power on prosocial outcomes: a self-validation analysis

    OpenAIRE

    DeMarree, Kenneth G.; Petty, Richard E.; Briñol Turnes, Pablo

    2012-01-01

    The present research distinguishes between primary (cognitive) and secondary (metacognitive) processes in the domain of power. Power is a central construct in economic decision making, influencing people’s thoughts and behavior in organizational, political, consumer, and interpersonal contexts. Whereas most research has discussed ways that power can influence primary cognition (e.g., increased self-focused thoughts, heuristic processing), we examine how power can influence secondary cognition...

  17. The effects of message recipients' power before and after persuasion: a self-validation analysis.

    Science.gov (United States)

    Briñol, Pablo; Petty, Richard E; Valle, Carmen; Rucker, Derek D; Becerra, Alberto

    2007-12-01

    In the present research, the authors examined the effect of a message recipient's power on attitude change and introduced a new mechanism by which power can affect social judgment. In line with prior research that suggested a link between power and approach tendencies, the authors hypothesized that having power increases confidence relative to being powerless. After demonstrating this link in Experiment 1, in 4 additional studies, they examined the role of power in persuasion as a function of when power is infused into the persuasion process. On the basis of the idea that power validates whatever mental content is accessible, they hypothesized that power would have different effects on persuasion depending on when power was induced. Specifically, the authors predicted that making people feel powerful prior to a message would validate their existing views and thus reduce the perceived need to attend to subsequent information. However, it was hypothesized that inducing power after a message has been processed would validate one's recently generated thoughts and thus influence the extent to which people rely upon their thoughts in determining their attitudes. (c) 2007 APA, all rights reserved.

  18. En annan bild av islam : En jämförelse av hur islam och muslimer framställs i svenska nyhetsmedier och i SVT:s dokumentärserie Jag är muslim

    OpenAIRE

    Bonnevier, Emilia

    2018-01-01

    Since Islam and Muslims are often portrayed in connection with terrorism, female oppression and security in Swedish news media, I decided I wanted to write my study on the subject “Islam and Swedish media”.   The aim with this study was to examine whether SVT’s documentary series Jag är muslim (I am Muslim in English) portrays Muslims differently from Swedish news media, and if so – how? To find out whether there was a difference, I used following questions: How are Islam and Muslims portraye...

  19. Investigating microbial colonization in actively forming hydrothermal deposits using thermocouple arrays

    Science.gov (United States)

    Tivey, M. K.; Reysenbach, A. L.; Hirsch, M.; Steinberg, J.; Flores, G. E.

    2010-12-01

    Investigations of microbial colonization of very young hydrothermal deposits were carried out in 2009 at hydrothermal vents in the Lau Basin (SW Pacific), and in Guaymas Basin, Gulf of California, with a test deployment at the Rainbow vent field on the Mid-Atlantic Ridge in 2008. Our method entailed razing active chimneys and placing arrays of temperature probes (8 titanium-encased probes with their tips placed within a titanium cage) over the active flow. The chimneys that grew back through each array, encasing the temperature probe tips, were recovered after 2 to 15 days, along with temperature records. Molecular phylogenetic methods are being used to reveal the members of the microbial communities that developed in each chimney of known age and thermal history. A total of 15 array deployments were made at 10 vents in 6 different vent fields. Similar morphology beehives (with porous fine-grained interiors and steep temperature gradients across the outermost more-consolidated “wall”) formed at 2 of the 3 vents in Guaymas Basin (in 2 and 5 days at one vent and 3 and 15 days at a second), and at one vent each in the Kilo Moana (in 3 days), Tahi Moana (in 2.5 days), and Tui Malila (in 3 and 8 days) vent fields in the Lau Basin. In contrast, open conduit, thin walled chimneys grew within arrays at the Mariner vent field, Lau Basin, at 3 different vents (in 3 days at one vent, in 3 and 11 days at a second vent, and in 13 days at a third vent). A lower temperature (Archaea showed very little change in diversity over time, with members of the genera Thermococcus and Methanocaldococcus present in all samples analyzed, irrespective of location and timing of sampling. This is very different from a 72-hour test array deployment done in 2008 at Rainbow vent field, where the deposited soft material was colonized only by the sulfate-reducing archaeum, Archaeoglobus. These samples (8 beehives, 4 open conduit smokers, one diffuser spire, from chimneys of known composition, plus less consolidated biofilm material) are all of known age, and fluids were collected from 7 of the 10 vents. This suite of samples will allow comparisons to data from 2003 (Page et al., 2008, Env. Micr.), study of the potential impact of fluid chemistry, mineralogy/texture, and time on microbial diversity, and testing of hypotheses about microbial colonization and succession.

  20. Liquid-solid contact measurements using a surface thermocouple temperature probe in atmospheric pool boiling water

    International Nuclear Information System (INIS)

    Lee, L.Y.W.; Chen, J.C.; Nelson, R.A.

    1984-01-01

    Objective was to apply the technique of using a microthermocouple flush-mounted at the boiling surface for the measurement of the local-surface-temperature history in film and transition boiling on high temperature surfaces. From this measurement direct liquid-solid contact in film and transition boiling regimes was observed. In pool boiling of saturated, distilled, deionized water on an aluminum-coated copper surface, the time-averaged, local-liquid-contact fraction increased with decreasing surface superheat. Average contact duration increased monotonically with decreasing surface superheat, while frequency of liquid contact reached a maximum of approx. 50 contacts/s at a surface superheat of approx. 100 K and decreased gradually to 30 contacts/s near the critical heat flux. The liquid-solid contact duration distribution was dominated by short contacts 4 ms at low surface superheats, passing through a relatively flat contact duration distribution at about 80 0 K. Results of this paper indicate that liquid-solid contacts may be the dominant mechanism for energy transfer in the transition boiling process

  1. Use of a thermocouple-datalogger system to evaluate overstory mortality

    Science.gov (United States)

    Lucy Brudnak; Thomas A. Waldrop; Ross J. Phillips

    2010-01-01

    In the past, it was difficult to accurately measure dynamic fire behavior during prescribed burns. Peak temperature, flaming duration, and total heat output may be directly related to first-order fire effects such as fuel consumption and vegetative mortality; however, little is known about which of these variables is most closely associated with, and therefore the best...

  2. Thermocouple-based Temperature Sensing System for Chemical Cell Inside Micro UAV Device

    Science.gov (United States)

    Han, Yanhui; Feng, Yue; Lou, Haozhe; Zhang, Xinzhao

    2018-03-01

    Environmental temperature of UAV system is crucial for chemical cell component inside. Once the temperature of this chemical cell is over 259 °C and keeps more than 20 min, the high thermal accumulation would result in an explosion, which seriously damage the whole UAV system. Therefore, we develop a micro temperature sensing system for monitoring the temperature of chemical cell thermally influenced by UAV device deployed in a 300 °C temperature environment, which is quite useful for insensitive munitions and UAV safety enhancement technologies.

  3. A Mathematical Technique for Estimating True Temperature Profiles of Data Obtained from Long Time Constant Thermocouples

    Science.gov (United States)

    1998-02-01

    zero, and has therefore been ignored. The inverse transform of Equation (11) (but ignoring the 5.8x) term, yields Equation (12), which is the...done for TC #1, this is ignored in the results. The inverse transform of Equation (14) (but ignoring the 10x) term, yields Equation (15), which is...2.568r 2.568 0.36 A^ —— + + —i— + + 0.36r (19) s s s s The inverse transform of Equation (19) (but ignoring the 0.36x) term, yields

  4. Temperature Measurements Using Type K Thermocouples and the Fluke Helios Plus 2287A Datalogger

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Vonbank, R.; Jensen, Rasmus Lund

    the circuit creates a circuit in which the two legs generate different voltages, leaving a small difference in voltage available for measurement (Figure 1). That difference increases with temperature, and can typically be between one and seventy micro-volts per Kelvin (μV/K) for the modern range of available...

  5. Heating Parameter Estimation Using Coaxial Thermocouple Gages in Wind Tunnel Test Articles.

    Science.gov (United States)

    1984-12-01

    Attack a Emissivity G Parameter Vector Pn Measurement Vector at nth Time Point p Density 0 Stefan-Boltzmann Constant 6 Transition Matrix APc Scaling...for. The radiation is modeled using the Stefan-Boltzmann Law, q = 60(U 4 - U, 4 ) (A-9) where 8 radiative emissivity a Stefan-Bol tzmann constant U...w00 I- 000 0 0111c :0 i zZ Z-4lwr I- E . - t J K - IL HHO "W 6i 0WZWZWO&000OW *0 . 0 - .- - -4 4 1"- 1 Lii w LiiU Li LI Li Lij Liw w ~ o 0 0wm ~wW6~w d

  6. Thermocouple module halt acceptance test report for tank 241-SY-101 DACS-1

    International Nuclear Information System (INIS)

    Larsen, D.C.

    1998-01-01

    Testing was started on February 24, 1998 and completed on February 25, 1998. The completed procedure consists of 4 acceptance test sections, 6.1 through 6.4. Three test exceptions were identified during the procedure. The first test exception was determined to be unrelated to the ATP and unfortunate that the instrument failed during the ATP. The next two test exceptions were disposition as acceptable because the alarming functions worked correctly in identifying a problem when software communications were interrupted. The test was completed satisfactorily over 2 days. The remainder of the acceptance test report is the completed test procedure

  7. Use of FET in automatic scanning of measurements using thermocouples and self-powered neutron detectors

    International Nuclear Information System (INIS)

    Plaige, Yves.

    1977-01-01

    Advantages lying in using FET switches in the relays of multiplexing systems are shown with two examples of application. Their performance as regard fast reliable operation are used in temperature measurement scanning inside nuclear reactors. As for current measurements using self-powered neutron detectors, the weak leakage currents of said switches ( [fr

  8. Temperature measurement in practice with resistance thermometers and thermocouples; Temperaturmesspraxis mit Widerstandsthermometern und Thermoelementen

    Energy Technology Data Exchange (ETDEWEB)

    Irrgang, K.; Michalowsky, L (eds.)

    2004-07-01

    The book addresses students of science and engineering, engineers and practicians in research and industry who are interested in temperature measurements and thermal processes in the temperature range between a few K and over 3200 K. For the first time ever, temperature sensors are classified on the basis of heat transport and heat transfer to the sensor as related to the technological aspects of sensor stress. This includes physical and materials-related fundamentals, materials selection, sensor design and optimisation, error analysis, as well as the analysis of economically relevant applications of electrical temperature measurement in thermal processes. [German] Dieses Buch wendet sich an Studenten der Natur- und Technikwissenschaften, Ingenieure und Hochschulabsolventen in der Forschung und Industrie, die sich mit Temperaturmessungen und thermischen Prozessen im Temperaturbereich von wenigen Kelvin bis zu ueber 3200 K befassen. Der neue Titel wird sich gegenueber bekannten Standards auf diesem Gebiet dadurch auszeichnen, dass eine Klassifizierung der Temperaturfuehler abhaengig vom Waermetransport und den Waermeuebergaengen zum Sensor in Verbindung mit den technologischen Aspekten zu den konkreten Beanspruchungen der Fuehler in der Anwendung vorgenommen wird. Dieser hohe Anspruch schliesst physikalische und werkstoffwissenschaftliche Grundlagen zur Systemloesung, der Werkstoffauswahl, zur Auslegung und Optimierung des Fuehlerdesigns und der notwendigen Fehlerbetrachtung ebenso ein, wie die Analyse volkswirtschaftlich bedeutsamer Anwendungen der elektrischen Temperaturmesstechnik in thermischen Prozessen. (orig.)

  9. New instruments and methods for high precision thermocouple and platinum resistance thermometry

    International Nuclear Information System (INIS)

    Corradi, F.

    1977-01-01

    The paper describes the development of measuring instruments for the following purposes: 1) Measurement of the super-heated steam temperature, close to 550 0 C, in a tube at approximately 200 Kg/cm 2 , with a total accuracy of +-0.1 0 C. 2) Measurement of the super-heated water temperature, close to 350 0 C, still with a total accuracy of +-0.1 0 C. 3) Measurement of temperature differences between the inlet and the outlet of the water in the supply channel. The mean temperature was close to 15 0 C and the differential span was required to be 0.5 0 C with a total accuracy of +-0.005 0 C. (orig./RW) [de

  10. Effect of thermo-coupled processes on the behaviour of a clay barrier submitted to heating and hydration

    Directory of Open Access Journals (Sweden)

    Marcelo Sánchez

    2010-03-01

    Full Text Available The storage of high level radioactive waste is still an unresolved problem of the nuclear industry, being geological disposal the most favoured option and, naturally, the one requiring the strongest geo-mechanical input. Most conceptual designs for the deep geological disposal of nuclear waste envisage placing the canisters containing the waste in horizontal drifts or vertical boreholes. The empty space surrounding the canisters is filled by an engineered barrier often made up of compacted swelling clay. Inthebarrierandthenearfield,significantthermo-hydro-mechanical(THM phenomena take place that interact in a complex way. A good understanding of THM issues is, therefore, necessary to ensure a correct performance of engineered barriers and seals. The conditions of the bentonite in an engineered barrier for high-level radioactive waste disposal are being simulated in a mock-up heating test at almost scale, at the premises of CIEMAT in Madrid. The evolution of the main Thermo-Hydro-Mechanical (THM variables of this test are analysed in this paper by using a fully coupled THM formulation and the corresponding finite element code. Special emphasis has been placed on the study of the effect of thermo-osmotic flow in the hydration of the clay barrier at an advanced staged of the experiment.O armazenamento de rejeitos altamente radioativos é ainda um problema em aberto na área de engenharia nuclear sendo os sítios geológicos ainda a opção mais favorável e naturalmente aquela que demanda maior conhecimento na área de geomecânica. A maioria dos projetos conceituais de armazenamento do lixo nuclear objetiva a alocação de cilindros que contêm os rejeitos em poços verticais ou horizontais. O espaço vazio que circunda os cilindros é preenchido por uma barreirade engenharia na maioria dos casos composta por uma argila expansiva. Na barreira e na vizinhança fenômenos significativos de acoplamento termo-hidro-mecânico(THM tomam lugar e interagem entre si de maneira bastante complexa. Um bom entendimento dos tópicos em acoplamento THM é portanto necessário para assegurar a boa performance das barreiras de engenharia. As condições da bentonita em uma barreira de engenharia para o armazenamento do lixo nuclear foram simuladas em um teste de calor experimental nas premissas do CIEMAT em Madrid. A evolução das variáveis que governam o acoplamento termo-hidro-mecânico neste teste são analisadas neste artigo utilizando uma formulação totalmente acoplada juntamente com o código computacional de elementos finitos. Ênfase especial é dada ao estudo do escoamento termo-osmótico na hidratação da barreira argilosa no estágio avançado do experimento.

  11. Thermo-coupled Surface Cauchy-Born Theory: An Engineering Finite Element Approach to Modeling of Nanowire Thermomechanical Response

    DEFF Research Database (Denmark)

    Esfahania, M. Nasr; Sonne, Mads Rostgaard; Hattel, J. Henri

    2016-01-01

    of thermal and mechanical stresses is achieved by eliminating the diagonalization matrix of entropy in the quasiharmonic system. This leads to a reduction in the degrees of freedom by more than 99} in comparison with equivalent Molecular Dynamics models. For the purpose of validation, results obtained...

  12. Examination of the suitability of noise thermometry for precise in situ calibration of thermocouples in technical processes

    International Nuclear Information System (INIS)

    Fechner, H.

    1988-12-01

    The aim was to determine the achievable accuracy of the noise thermometer developed at the KFA in the range from 0 to 1000 0 C under laboratory conditions. Precision noise temperature measurements at fixed temperature points (triple point of water, freezing point of zinc and silver) were carried out. The fixed point technique and the conventional precision resistance thermometry, which is required to operate the fixed points, were established in accordance with the requirements of accurate (and thus longer lasting) noise temperature measurements. The analysis of all possible sources of error ensured that all systematic or random errors were in the range of a few 10 -5 . The further developed KFA noise thermometers, which can be used under industrial conditions, achieve under laboratory conditions a measuring error of about ±2.5 10 -4 - relative to the thermodynamic temperature scale - in the temperature range from 273.16 K (0.01 0 C) to 1234.894 K (961.744 0 C). Assuming that the individual measured values display a normal distribution, the noise measurements at the zinc and silver point are combined to a mean value, it becomes apparent that the average noise temperatures only deviate by +2 10 -5 (zinc) or +4 10 -5 (silver) from the respective thermodynamic temperature. (orig./HP) [de

  13. Application of existing iron-babbitt metal pairing in slide bearings as a thermocouple in technical diagnostics

    International Nuclear Information System (INIS)

    Herrmann, D.; Schmidt, U.

    1979-01-01

    Temperature can be used as a parameter in technical diagnostics of slide bearings. A novel, very simple method of nonpointlike temperature measurement is proposed. The salient advantage of this method is the fact that there is no necessity of influencing the bearing. (author)

  14. Pyrolysis of polystyrene waste in the presence of activated carbon in conventional and microwave heating using modified thermocouple.

    Science.gov (United States)

    Prathiba, R; Shruthi, M; Miranda, Lima Rose

    2018-06-01

    Pyrolysis process was experimented using two types of heating source, namely conventional and microwave. Polystyrene (PS) plastic waste was used as feedstock in a batch reactor for both the conventional (slow pyrolysis) and microwave pyrolysis. The effect of activated carbon to polystyrene ratio on (i) yield of oil, gas and residues (ii) reaction temperature (iii) reaction time were studied. Quality of oil from pyrolysis of polystyrene were assessed for the possible applicability in fuel production. Microwave power of 450 W and polymer to activated carbon ratio of 10:1, resulted in the highest oil yield of 93.04 wt.% with a higher heating value of 45 MJ kg -1 and a kinematic viscosity of 2.7 cSt. Microwave heating when compared to conventional heating method, exhibits a reaction temperature and time of 330 °C in 5.5 min, whereas in conventional heating system it was 418 °C in 60 min. The gas chromatography-mass spectrometry analysis of liquid oil from microwave pyrolysis predominantly yields alkenes of 8.44 wt.%, α-methyl styrene 0.96 wt.%, condensed ring aromatics 23.21 wt.% and benzene derivatives 26.77 wt.% when the polystyrene to activated carbon ratio was 10:1. Significant factor of using microwave heating is the amount of energy converted (kWh) is lesser than conventional heating. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Brazed thermocouple pass-through for sodium service in a liquid-metal-cooled fast breeder reactor

    International Nuclear Information System (INIS)

    Walker, D.E.

    1975-10-01

    Sensors installed in special fuel elements for the EBR-II reactor had 30-ft-long leads that would pass from the sodium environment through a sealed bulkhead. A hydrogen-atmosphere, induction-heated brazing furnace was constructed to simultaneously braze 20-26 separate sensor leads at one time. The brazed seals were leak-tight, and the sheath wall has less than 10 percent interaction with the braze alloy

  16. Singing voice outcomes following singing voice therapy.

    Science.gov (United States)

    Dastolfo-Hromack, Christina; Thomas, Tracey L; Rosen, Clark A; Gartner-Schmidt, Jackie

    2016-11-01

    The objectives of this study were to describe singing voice therapy (SVT), describe referred patient characteristics, and document the outcomes of SVT. Retrospective. Records of patients receiving SVT between June 2008 and June 2013 were reviewed (n = 51). All diagnoses were included. Demographic information, number of SVT sessions, and symptom severity were retrieved from the medical record. Symptom severity was measured via the 10-item Singing Voice Handicap Index (SVHI-10). Treatment outcome was analyzed by diagnosis, history of previous training, and SVHI-10. SVHI-10 scores decreased following SVT (mean change = 11, 40% decrease) (P singing lessons (n = 10) also completed an average of three SVT sessions. Primary muscle tension dysphonia (MTD1) and benign vocal fold lesion (lesion) were the most common diagnoses. Most patients (60%) had previous vocal training. SVHI-10 decrease was not significantly different between MTD and lesion. This is the first outcome-based study of SVT in a disordered population. Diagnosis of MTD or lesion did not influence treatment outcomes. Duration of SVT was short (approximately three sessions). Voice care providers are encouraged to partner with a singing voice therapist to provide optimal care for the singing voice. This study supports the use of SVT as a tool for the treatment of singing voice disorders. 4 Laryngoscope, 126:2546-2551, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Asthma-like attacks terminated by slow pathway ablation

    Directory of Open Access Journals (Sweden)

    Selcuk Ozturk

    2017-01-01

    Full Text Available Asthma is a chronic airway disease in which the pathological mechanisms are reversible airway obstruction, bronchial hyper reactivity, and constriction of the lower airways. Supraventricular tachycardia (SVT is a common arrhythmia which originates above the bundle of His and causing heart rates exceeding 150 beats/min. SVT patients present with palpitation, chest pain, chest discomfort, dyspnea, hyperventilation, and lightheadedness, occasionally. Besides, extraordinary presentations of SVT are available in literature. In this report, we describe a case of a patient presenting with treatment-resistant asthma-like attacks lasting for 20 years whom was suspected SVT as an underlying etiology and treated by slow pathway radiofrequency ablation.

  18. Diagnostik og behandling af paroksystisk supraventrikulær takykardi

    DEFF Research Database (Denmark)

    Rujic, Dragana; Sundbøll, Jens; Tofig, Bawer Jalal

    2016-01-01

    management strategies. The probable mechanism of paroxysmal SVT can often be diagnosed from the clinical findings and a 12-lead ECG. This review describes the initial evaluation and treatment of patients with paroxysmal SVT, including distinctive features from the most important differential diagnoses....

  19. CDF silicon vertex tracker: tevatron run II preliminary results

    International Nuclear Information System (INIS)

    Ashmanskas, W.; Belforte, S.; Budagov, Yu.

    2002-01-01

    The Online Silicon Vertex Tracker (SVT) is the unique new trigger processor dedicated to the 2-D reconstruction of charged particle trajectories at Level 2 of the CDF trigger. The SVT has been successfully built, installed and operated during the 2000 and 20001 CDF data taking runs. The performance of the SVT is already very close to the design. The SVT is able to find tracks and calculate their impact parameter with high precision (σ d = 35 μm). It is possible to correct the beam position offset and give the beam position feedback to accelerator in real time. In fact, the beam position is calculated online every few seconds with an accuracy of 1 to 5 μm. The beam position is continuously sent to the accelerator control. By using trigger tracks, parent particles such as K S 's and D 0 's are reconstructed, proving that the SVT is ready to be used for physics studies

  20. Acute supraventricular tachycardia in children.

    Science.gov (United States)

    Paul, Siba Prosad; Blaikley, Sarah; Peevers, Camilla; Fitz-John, Lin

    2012-10-01

    This article describes the management in emergency departments of supraventricular tachycardia (SVT) in children. Of all forms of symptomatic arrhythmia in infants, children and adolescents, SVT is the most common. Its clinical presentation varies with the child's age, and it can be difficult to diagnose in infants and young children. It is important that the nurses in the emergency department consider a diagnosis of SVT in young children with histories of poor feeding, lethargy, irritability, excessive sweating or pallor (Zeigler 1994) and in older children with histories of palpitations, dizziness, chest pain, syncope or shortness of breath (Uzun 2010). If SVT is suspected, a 12-lead electrocardiogram should be recorded. Vagal manoeuvre may be successful but in some cases intravenous adenosine is necessary. Children with Wolff-Parkinson-White syndrome are at risk of sudden cardiac death associated with SVT, and should not be treated with calcium channel blockers or digoxin.

  1. Treatment of out-of-hospital supraventricular tachycardia: adenosine vs verapamil.

    Science.gov (United States)

    Brady, W J; DeBehnke, D J; Wickman, L L; Lindbeck, G

    1996-06-01

    To compare the use of adenosine and the use of verapamil as out-of-hospital therapy for supraventricular tachycardia (SVT). A period of prospective adenosine use (March 1993 to February 1994) was compared with a historical control period of verapamil use (March 1990 to February 1991) for SVT. Data were obtained for SVT patients treated in a metropolitan, fire-department-based paramedic system serving a population of approximately 1 million persons. Standard drug protocols were used and patient outcomes (i.e., conversion rates, complications, and recurrences) were monitored. During the adenosine treatment period, 105 patients had SVT; 87 (83%) received adenosine, of whom 60 (69%) converted to a sinus rhythm (SR). Vagal maneuvers (VM) resulted in restoration of SR in 8 patients (7.6%). Some patients received adenosine for non-SVT rhythms: 7 sinus tachycardia, 18 atrial fibrilation, 7 wide-complex tachycardia (WCT), and 2 ventricular tachycardia; no non-SVT rhythm converted to SR and none of these patients experienced an adverse effect. Twenty-five patients were hemodynamically unstable (systolic blood pressure fibrillation). Recurrence of SVT was noted in 2 adenosine patients and 2 verapamil patients in the out-of-hospital setting and in 23 adenosine patients and 15 verapamil patients after ED arrival, necessitating additional therapy (p = 0.48 and 0.88, for recurrence rates and types of additional therapies, respectively). Hospital diagnoses, outcomes, and ED dispositions were similar for the 2 groups. Adenosine and verapamil were equally successful in converting out-of-hospital SVT in patients with similar etiologies responsible for the SVT. Recurrence of SVT occurred at similar rates for the 2 medications. Rhythm misidentification remains a common issue in out-of-hospital cardiac care in this emergency medical services system.

  2. Risk factors and outcome of splanchnic venous thrombosis in patients with necrotizing acute pancreatitis.

    Science.gov (United States)

    Zhou, Jing; Ke, Lu; Tong, Zhihui; Li, Gang; Li, Weiqin; Li, Ning; Li, Jieshou

    2015-01-01

    Splanchnic venous thrombosis (SVT) is considered a rare but important complication in patients with acute pancreatitis (AP) and literatures regarding this topic were sparse. The aim of the present study was to investigate the risk factors of SVT in necrotizing acute pancreatitis (NAP) and assess the prognosis of these patients. Both univariate and multivariate logistic regression analyses were applied using 15 indices including age, gender, Acute Physiology and Chronic Health Evaluation II scores (APACHE II), CRP (C - reactive protein) levels, etc to explore potential risk factors for the development of SVT in NAP patients. Moreover, clinical outcome measures such as mortality, organ failure and length of hospital and ICU stay were also compared between NAP patients with or without SVT. According to the statistical results, only intra-abdominal pressure (IAP) was proved to be an independent risk factor for SVT (OR, 1.283; 95% CI, 1.091-1.509,P=0.003). In addition, Balthazar's CT score and occurrence of IPN (infected pancreatic necrosis) also reached statistical significance (P=0.040 and 0.047, respectively), but the 95% confidence interval shown in the multivariate logistic regression suggested that the observed ORs are not significant (1.326;95% CI 0.984-1.787 and 2.61;95 CI 0.972-7.352, respectively), which indicates weaker association between the two parameters and SVT. Regarding the clinical outcomes, patients with SVT showed higher mortality, longer hospital and intensive care unit duration, higher rates of a variety of complications and more utilization of invasive interventions. IAP is an independent risk factor for the development of SVT in patients with NAP, while Balthazar's CT score and occurrence of IPN are also associated with SVT, although not as strong as IAP. Moreover, occurrence of SVT relates with extremely poor prognosis in NAP patients, evidenced by increased mortality, morbidity and need for invasive interventions. Copyright © 2014 Elsevier

  3. Thermocouple and controlling cables of electric penetrations for nuclear power stations. hermetization with glass-ceramic and glass-fiber materials

    International Nuclear Information System (INIS)

    Kostyukov, N.S.; Golovko, T.A.; Okhotnikova, G.G.

    1996-01-01

    New perspective technology for hermetization of cable ends for fabrication of hermetical inlets for NPPs with inorganic materials is developed. On the basis of the studies dielectric inorganic materials, resistive to γ-radiation and fire, are selected for creation of hermetically sealed inlets. Principally new methods for fabrication of hermoinlets is developed on the basis of metallic modules with fibre circuitously and ceramic hermetization units

  4. Pyrexia's effect on the CBG-cortisol thermocouple, rather than CBG cleavage, elevates the acute free cortisol response to TNF-α in humans

    DEFF Research Database (Denmark)

    Nenke, Marni Anne; Nielsen, Signe Tellerup; Lehrskov, Louise Lang

    2017-01-01

    an inflammatory stimulus is unknown. Hence our aim was to determine the immediate effect of the key pro-inflammatory cytokine TNF-α on CBG levels and cleavage. We performed a crossover study of 12 healthy males receiving a TNF-α versus saline infusion, measuring total CBG, haCBG, laCBG and free and total cortisol...... hourly for 6 h. There was no change in total CBG or haCBG levels in the first 6 h of inflammation between the groups, suggesting that CBG cleavage is not activated nor is hepatic CBG production affected by TNF-α in this time frame. There was an early increase in the ratio of free:total cortisol...

  5. Determination of hydrogen permeation using metallic sensors of construction similar to bimetallic thermocouples; Determinacao de permeacao de hidrogenio utilizando sensores metalicos de construcao similar a termopares bimetalicos

    Energy Technology Data Exchange (ETDEWEB)

    Maul, Alexandre M. [Ministerio de Ciencia e Tecnologia (MCT), Brasilia, DF (Brazil). Programa de Pos-graduacao em Engenharia e Processos (PIPE- PRH-24/ANP); Ponte, Haroldo A. [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Correa, Luiz A. [Metaldata Tecnologia de Materiais, Curitiba, PR (Brazil)] (in Memoriam)

    2004-07-01

    Crude oils range in consistency from water to tar-like solids, and in color from clear to black. An average crude oil contains about 84 percent carbon, 14 percent hydrogen, 1 to 3 percent sulfur, and less than 1 percent each of nitrogen, oxygen, metals, and salts. Crude oils are generally classified as paraffinic, naphthenic, or aromatic based on the predominant proportion of similar hydrocarbon molecules. Refinery crude base stocks usually consist of mixtures of two or more different crude oils. Many corrosive processes found in machines, equipment and pipes used in the petroleum industry are directly influenced by hydrogen. The structural damages are caused by hydrogen inclusion in metallic structures, generated by acid media that contain free protons (H{sup +}), by chemical processes that lead to the protons formation, by formation of atomic hydrogen (H0) or even by adsorbed gas hydrogen (H2). The structural damages are varied: hydrogen induced cracking (HIC), blistering, stress corrosion cracking (SSC), stress oriented hydrogen induced cracking (SOHIC). The main problem found in practice is how to detect, in a safe, fast and economically viable way, the formation of hydrogen close to a surface subjected to hydrogen permeation. Within this work, we built a cell for hydrogen generation/permeation to study and evaluate a new hydrogen sensor. This new sensor is composed of two parts, each one build with a couple of dissimilar materials, being a sensor couple, for hydrogen flux measurement, and a reference couple, for temperature corrections. In this sensor, the changes in some physical properties are related with the flow of permeated hydrogen. The results using a prototype model showed good agreement with a traditional Devanathan-Stachurski sensor. (author)

  6. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    Science.gov (United States)

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  7. Splenic vein thrombosis with chronic pancreatitis: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Nasiri SH, Khorgami J, Donboli K

    2008-07-01

    Full Text Available "nBackground: Chronic pancreatitis and perivasculitis is the most common etiology of splenic vein thrombosis (SVT. Reported in up to 45% of patients with chronic pancreatitis, SVT may also be seen in patients with acute pancreatitis and pancreatic adenocarcinoma. It causes a localized portal hypertension called sinistral portal hypertension. Unlike those with generalized portal hypertension, patients with sinistral portal hypertension are asymptomatic and have normal liver function. Upper gastrointestinal bleeding from gastric varices is a life threatening complication of SVT. In patients with gastrointestinal bleeding secondary to esophageal or gastric varices, late-phase celiac angiography is used to determine the presence SVT. Splenectomy is effective in treating the collateral outflow for patients with massive gastrointestinal bleeding."n"nCase report: a 23-year-old patient with SVT due to chronic pancreatitis with gastrointestinal bleeding. The patient came to the hospital with upper gastrointestinal bleeding of unknown etiology. Diagnostic workups revealed chronic pancreatitis and SVT with bleeding gastric fundal varices, after which the patient underwent splenectomy. A review of current literature on SVT, known etiologies, diagnosis and treatment is discussed

  8. The value of adrenaline in the induction of supraventricular tachycardia in the electrophysiological laboratory.

    Science.gov (United States)

    Cismaru, Gabriel; Rosu, Radu; Muresan, Lucian; Puiu, Mihai; Andronache, Marius; Hengan, Erika; Ispas, Daniel; Gusetu, Gabriel; Pop, Dana; Mircea, Petru Adrian; Zdrenghea, Dumitru

    2014-11-01

    The most commonly used drug for the facilitation of supraventricular tachycardia (SVT) induction in the electrophysiological (EP) laboratory is isoprenaline. Despite isoprenaline's apparent indispensability, availability has been problematic in some European countries. Alternative sympatomimethic drugs such as adrenaline have therefore been tried. However, no studies have determined the sensitivity and specificity of adrenaline for the induction of SVT. The objective of this study was to determine the sensitivity and specificity of adrenaline for the induction of SVT. Between February 2010 and July 2013, 336 patients underwent an EP study for prior documented SVT. In 66 patients, adrenaline was infused because tachycardia was not induced under basal conditions. This group was compared with 30 control subjects with no history of SVT. Programmed atrial stimulation was carried out during baseline state and repeated after an infusion of adrenaline (dose ranging from 0.05 mcg/kgc to 0.3 mcg/kgc). The endpoint was the induction of SVT. Among 66 patients with a history of SVT but no induction under basal conditions, adrenaline facilitated induction in 54 patients (82%, P Adrenaline was generally well tolerated, except for two patients (3.0%), where it had to be discontinued due to headache and high blood pressure or lumbar pain. Adrenaline infusion has a high sensitivity (82%) and specificity (100%) for the induction of SVT in patients with prior documented SVT. Therefore, it could serve as an acceptable alternative to isoprenaline, when the latter is not available. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  9. Radiation monitoring with CVD diamonds and PIN diodes at BaBar

    Energy Technology Data Exchange (ETDEWEB)

    Bruinsma, M. [University of California Irvine, Irvine, CA 92697 (United States); Burchat, P. [Stanford University, Stanford, CA 94305-4060 (United States); Curry, S. [University of California Irvine, Irvine, CA 92697 (United States)], E-mail: scurry@slac.stanford.edu; Edwards, A.J. [Stanford University, Stanford, CA 94305-4060 (United States); Kagan, H.; Kass, R. [Ohio State University, Columbus, OH 43210 (United States); Kirkby, D. [University of California Irvine, Irvine, CA 92697 (United States); Majewski, S.; Petersen, B.A. [Stanford University, Stanford, CA 94305-4060 (United States)

    2007-12-11

    The BaBar experiment at the Stanford Linear Accelerator Center has been using two polycrystalline chemical vapor deposition (pCVD) diamonds and 12 silicon PIN diodes for radiation monitoring and protection of the Silicon Vertex Tracker (SVT). We have used the pCVD diamonds for more than 3 years, and the PIN diodes for 7 years. We will describe the SVT and SVT radiation monitoring system as well as the operational difficulties and radiation damage effects on the PIN diodes and pCVD diamonds in a high-energy physics environment.

  10. Superficial Vein Thrombophlebitis in a Football Athlete.

    Science.gov (United States)

    Schleich, Kevin T; Smoot, M Kyle

    2016-03-01

    A 22-year-old professional football player presented to a preparticipation physical examination with a 2-week history of left leg discomfort extending from the groin to the knee over the previous 2 weeks. He was found to have superficial vein thrombophlebitis (SVT) of the left great saphenous vein extending from the knee to within approximately 1.6 cm of the saphenofemoral junction. There is paucity in the literature regarding the management of SVT, particularly in actively training athletes. This case addresses the considerations of anticoagulation management for SVT as well as the unique challenge of managing anticoagulation therapy in an athlete that is actively training.

  11. Uncooled High-Performance InAsSb Focal Plane Arrays, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — SVT Associates proposes an innovative digital alloy technique to extend the cutoff wavelength of InAsSb beyond 5 um, a wider band gap InAlAsSb layer inserted into...

  12. Supraventricular tachyarrhythmias after myocardial revascularization: a randomized trial of prophylactic digitalization.

    Science.gov (United States)

    Tyras, D H; Stothert, J C; Kaiser, G C; Barner, H B; Codd, J E; Willman, V L

    1979-02-01

    The success of prophylactic digitalization in reducing the incidence of supraventricular tachyarrhythmias (SVT) was studied in 140 randomly grouped, consecutive patients undergoing myocardial revascularization operations. The test group received either 1 or 1.5 mg. of digoxin the day before operation and were maintained postoperatively on 0.25 mg. of digoxin daily. There was a significant increase (p less than 0.05) in the incidence of SVT in the treated patients (17 of 61 or 27.8 percent) vs. the untreated patients (nine of 79 or 11.4 percent). There was no significant difference in SVT with the two digitalization dosage levels (31.6 percent with 1 mg. vs. 21.7 percent with 1.5 mg.). Prophylactic digitalization demonstrates no benefit in the prevention of SVT following myocardial revascularization and may, in fact, predispose the patient to these arrhythmias.

  13. Splanchnic venous thrombosis driven by a constitutively activated ...

    African Journals Online (AJOL)

    Introduction: Splanchnic venous thrombosis (SVT) has varied etiology with Philadelphia-negative myeloproliferative neoplasms (MPNs) being the most frequent underlying prothrombotic factor. Hematological indices often remain within normal range because of portal hypertension and its sequelae, causing diagnostic ...

  14. Adenosine induced ventricular arrhythmias in the emergency room

    NARCIS (Netherlands)

    Tan, H. L.; Spekhorst, H. H.; Peters, R. J.; Wilde, A. A.

    2001-01-01

    While adenosine effectively terminates most supraventricular tachycardias (SVT), rare case reports have demonstrated its proarrhythmic potential, including induction of ventricular tachycardia (VT). The aim of this study was to define the proarrhythmic effects of adenosine in a large, unselected

  15. Splanchnic venous thrombosis driven by a constitutively activated ...

    African Journals Online (AJOL)

    sated chronic liver disease found to have SVT- portal vein thrombosis and how JAK2 V617F was useful in unmasking an ... to over proliferation of the myeloid series. .... gression to acute leukemia and myelofibrosis. .... factors and treatment.

  16. Mechanical circulatory treatment of advanced heart failure

    DEFF Research Database (Denmark)

    Rujic, Dragana; Sundbøll, Jens; Tofig, Bawer Jalal

    2016-01-01

    The paroxysmal supraventricular tachycardias (SVT) are commonly encountered arrhythmias and include atrioventricular nodal re-entrant tachycardia, atrioventricular reciprocating tachycardia, and focal atrial tachycardia. These tachycardias share several clinical features as well as similar manage...

  17. Factors associated with therapeutic strategies in patients with splanchnic vein thrombosis: Results of an international registry

    NARCIS (Netherlands)

    Riva, N.; Ageno, W.; Schulman, S.; Bang, S.M.; Sartori, M.T.; Grandone, E.; Beyer, J.; Barillari, G.; Di Minno, D.; Duce, R.; Malato, A.; Santoro, R.; Poli, D.; Verhamme, P.; Martinelli, I.; Kamphuisen, P.; Alatri, A.; Becattini, C.; Bucherini, E.; Piana, A.; De Stefano, V.; Dentali, F.

    2012-01-01

    Background Treatment of splanchnic vein thrombosis (SVT) is challenging due to the heterogeneous clinical presentation and the increased bleeding risk. We aimed to describe current treatment strategies and factors associated with therapeutic decisions. Materials and Methods Between May 2008 and

  18. Idiopathic versus secondary venous thromboembolism. Findings of the RIETE registry.

    Science.gov (United States)

    Pedrajas, J M; Garmendia, C; Portillo, J; Gabriel, F; Mainez, C; Yera, C; Monreal, M

    2014-10-01

    The Computerized Registry of Patients with Venous Thromboembolism (RIETE) is a prospective registry that consecutively includes patients diagnosed with venous thromboembolism. We compared the clinical presentation and response to anticoagulant treatment in patients with idiopathic venous thromboembolism (IVT) versus secondary venous thromboembolism (SVT, associated with a risk factor). We analyzed the differences in clinical characteristics, comorbidity, treatment and events during the first 3months after the diagnosis of venous thromboembolism in patients with IVT or SVT and according to their initial clinical presentation. A total of 39,921 patients with IVT (n=18,029; 45.1%) or SVT (n=21,892; 54.9%) were enrolled. The patients with IVT had a greater history of venous thromboembolism than those diagnosed with SVT (p<.001). The initial treatment was similar for the 2 groups, but more inferior vena cava filters were placed in the SVT group (p<.001). In the long term, low-molecular-weight heparin was used more often in the SVT group than in the IVT group. At 90days, bleeding, death and the recurrence of venous thromboembolism were significantly more frequent in the SVT group. The multivariate analysis confirmed that IVT was associated with fewer major (OR, 0.60; 95%CI, 0.50-0.61; p<.001) and fatal (OR, 0.41; 95%CI, 0.29-0.62; p<.001) bleedings, fewer relapses (OR, 0.58; 95%CI, 0.39-0.78; p<.001) and fewer fatal pulmonary embolisms (OR, 0.29; 95%CI, 0.12-0.52; p<.001). These differences were maintained in patients whose venous thromboembolism started with a pulmonary embolism or with deep vein thrombosis. IVT has a better prognosis than SVT at 90days of the diagnosis. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  19. The BaBar silicon vertex tracker, performance and running experience

    International Nuclear Information System (INIS)

    Re, V.; Borean, C.; Bozzi, C.; Carassiti, V.; Cotta Ramusino, A.; Piemontese, L.; Breon, A.B.; Brown, D.; Clark, A.R.; Goozen, F.; Hernikl, C.; Kerth, L.T.; Gritsan, A.; Lynch, G.; Perazzo, A.; Roe, N.A.; Zizka, G.; Roberts, D.; Schieck, J.; Brenna, E.; Citterio, M.; Lanni, F.; Palombo, F.; Ratti, L.; Manfredi, P.F.; Angelini, C.; Batignani, G.; Bettarini, S.; Bondioli, M.; Bosi, F.; Bucci, F.; Calderini, G.; Carpinelli, M.; Ceccanti, M.; Forti, F.; Gagliardi, D.; Giorgi, M.A.; Lusiani, A.; Mammini, P.; Morganti, M.; Morsani, F.; Neri, N.; Paoloni, E.; Profeti, A.; Rama, M.; Rizzo, G.; Sandrelli, F.; Simi, G.; Triggiani, G.; Walsh, J.; Burchat, P.; Cheng, C.; Kirkby, D.; Meyer, T.I.; Roat, C.; Bona, M.; Bianchi, F.; Gamba, D.; Trapani, P.; Bosisio, L.; Della Ricca, G.; Dittongo, S.; Lanceri, L.; Pompili, A.; Poropat, P.; Rashevskaia, I.; Vuagnin, G.; Burke, S.; Callahan, D.; Campagnari, C.; Dahmes, B.; Hale, D.; Hart, P.; Kuznetsova, N.; Kyre, S.; Levy, S.; Long, O.; May, J.; Mazur, M.; Richman, J.; Verkerke, W.; Witherell, M.; Beringer, J.; Eisner, A.M.; Frey, A.; Grillo, A.A.; Grothe, M.; Johnson, R.P.; Kroeger, W.; Lockman, W.S.; Pulliam, T.; Rowe, W.; Schmitz, R.E.; Seiden, A.; Spencer, E.N.; Turri, M.; Walkowiak, W.; Wilder, M.; Wilson, M.; Charles, E.; Elmer, P.; Nielsen, J.; Orejudos, W.; Scott, I.; Zobernig, H.

    2002-01-01

    The Silicon Vertex Tracker (SVT) of the BaBar experiment at the PEP-II asymmetric B factory is a five-layer double-sided, AC-coupled silicon microstrip detector. It represents the crucial element to precisely measure the decay position of B mesons and extract time-dependent CP asymmetries. The SVT architecture is shown and its performance is described, with emphasis on hit resolutions and efficiencies

  20. Inhibitory effect of snake venom toxin on NF-κB activity prevents human cervical cancer cell growth via increase of death receptor 3 and 5 expression.

    Science.gov (United States)

    Lee, Hye Lim; Park, Mi Hee; Hong, Ji Eun; Kim, Dae Hwan; Kim, Ji Young; Seo, Hyen Ok; Han, Sang-Bae; Yoon, Joo Hee; Lee, Won Hyoung; Song, Ho Sueb; Lee, Ji In; Lee, Ung Soo; Song, Min Jong; Hong, Jin Tae

    2016-02-01

    We previously found that snake venom toxin inhibits nuclear factor kappa B (NF-κB) activity in several cancer cells. NF-κB is implicated in cancer cell growth and chemoresistance. In our present study, we investigated whether snake venom toxin (SVT) inhibits NF-κB, thereby preventing human cervical cancer cell growth (Ca Ski and C33A). SVT (0-12 μg/ml) inhibited the growth of cervical cancer cells by the induction of apoptotic cell death. These inhibitory effects were associated with the inhibition of NF-κB activity. However, SVT dose dependently increased the expression of death receptors (DRs): DR3, DR5 and DR downstream pro-apoptotic proteins. Exploration of NF-κB inhibitor (Phenylarsine oxide, 0.1 μM) synergistically further increased SVT-induced DR3 and DR5 expressions accompanied with further inhibition of cancer cells growth. Moreover, deletion of DR3 and DR5 by small interfering RNA significantly abolished SVT-induced cell growth inhibitory effects, as well as NF-κB inactivation. Using TNF-related apoptosis-inducing ligand resistance cancer cells (A549 and MCF-7), we also found that SVT enhanced the susceptibility of chemoresistance of these cancer cells through down-regulation of NF-κB, but up-regulation of DR3 and DR5. In vivo study also showed that SVT (0.5 and 1 mg/kg) inhibited tumor growth accompanied with inactivation of NF-κB. Thus, our present study indicates that SVT could be applicable as an anticancer agent for cervical cancer, or as an adjuvant agent for chemoresistant cancer cells.

  1. The BaBar silicon vertex tracker, performance and running experience

    CERN Document Server

    Re, V; Bozzi, C; Carassiti, V; Cotta-Ramusino, A; Piemontese, L; Breon, A B; Brown, D; Clark, A R; Goozen, F; Hernikl, C; Kerth, L T; Gritsan, A; Lynch, G; Perazzo, A; Roe, N A; Zizka, G; Roberts, D; Schieck, J; Brenna, E; Citterio, M; Lanni, F; Palombo, F; Ratti, L; Manfredi, P F; Angelini, C; Batignani, G; Bettarini, S; Bondioli, M; Bosi, F; Bucci, F; Calderini, G; Carpinelli, M; Ceccanti, M; Forti, F; Gagliardi, D J; Giorgi, M A; Lusiani, A; Mammini, P; Morganti, M; Morsani, F; Neri, N; Paoloni, E; Profeti, A; Rama, M; Rizzo, G; Sandrelli, F; Simi, G; Triggiani, G; Walsh, J; Burchat, Patricia R; Cheng, C; Kirkby, D; Meyer, T I; Roat, C; Bóna, M; Bianchi, F; Gamba, D; Trapani, P; Bosisio, L; Della Ricca, G; Dittongo, S; Lanceri, L; Pompili, A; Poropat, P; Rashevskaia, I; Vuagnin, G; Burke, S; Callahan, D; Campagnari, C; Dahmes, B; Hale, D; Hart, P; Kuznetsova, N; Kyre, S; Levy, S; Long, O; May, J; Mazur, M; Richman, J; Verkerke, W; Witherell, M; Beringer, J; Eisner, A M; Frey, A; Grillo, A A; Grothe, M; Johnson, R P; Kröger, W; Lockman, W S; Pulliam, T; Rowe, W; Schmitz, R E; Seiden, A; Spencer, E N; Turri, M; Walkowiak, W; Wilder, M; Wilson, M; Charles, E; Elmer, P; Nielsen, J; Orejudos, W; Scott, I; Zobernig, H

    2002-01-01

    The Silicon Vertex Tracker (SVT) of the BaBar experiment at the PEP-II asymmetric B factory is a five-layer double-sided, AC-coupled silicon microstrip detector. It represents the crucial element to precisely measure the decay position of B mesons and extract time-dependent CP asymmetries. The SVT architecture is shown and its performance is described, with emphasis on hit resolutions and efficiencies.

  2. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PRSVT limit); and (3) algorithm limitations (atrial tachycardia with ventricular rate around the shortest programmable SVT limit and SVT redetection following VT therapy). Programming measures improved detection ability in 13 of 59 of inappropriately detected arrhythmias. Dual chamber detection algorithms evaluated in a subset of diagnostically difficult arrhythmias allow safe detection of double tachycardias but require further extension and programmability to

  3. Postexertional Supraventricular Tachycardia in Children with Catecholaminergic Polymorphic Ventricular Tachycardia

    Directory of Open Access Journals (Sweden)

    Scott D. N. Else

    2012-01-01

    Full Text Available Catecholaminergic polymorphic ventricular tachycardia (CPVT is a severe arrhythmia associated with sudden death in the young. It is caused by defective calcium handling in ventricular myocytes. The association of supraventricular tachycardia (SVT with CPVT is described in the literature, occurring in the lead-up to ventricular tachycardia during exercise testing. We describe three cases of SVT that were initiated in the recovery period of exercise testing in children with CPVT.

  4. Management of supraventricular tachycardia using the Valsalva manoeuvre: a historical review and summary of published evidence.

    Science.gov (United States)

    Smith, Gavin

    2012-12-01

    Use of the Valsalva manoeuvre (VM) as a first-line management tool for the reversion of supraventricular tachycardia (SVT) in both emergency medicine and prehospital emergency-care settings has presented challenges, requiring continuous examination and refinement to define both its appropriateness and effectiveness. This report details the evolution of knowledge related to SVT and the historical evolution and controversies associated with VM; it also highlights the ongoing development of an evidence-based model of practice for the management of SVT in the emergency medicine and prehospital emergency-care settings. A two-part review of the literature using electronic medical databases was conducted. Other relevant texts or articles unavailable within the electronic search were also identified. Part 1 of the search criteria identified the historical evolution of the pathophysiology of SVT, whereas part 2 identified the use of VM for the clinical management of SVT. Part 1 of the review identified a total of 38 articles with eight meeting the inclusion criteria, and part 2 of the review identified a total of 44 articles with 17 meeting the inclusion criteria. An evidence-based model of practice requires clarification. The differentiation of nodal re-entrant tachycardias may, with further research, lead to identification of the specificity of VM in reversion of SVT during the early stages of arrhythmia. There is a need for further prehospital and emergency department research to quantify an evidence-based approach to VM.

  5. Recurrent Thrombotic Events after Discontinuation of Vitamin K Antagonist Treatment for Splanchnic Vein Thrombosis: A Multicenter Retrospective Cohort Study

    Directory of Open Access Journals (Sweden)

    Nicoletta Riva

    2015-01-01

    Full Text Available It is generally recommended that patients with splanchnic vein thrombosis (SVT should receive a minimum of 3 months of anticoagulant treatment. However, little information is available on the long-term risk of recurrent thrombotic events. The aim of this study was to evaluate the risk of venous and arterial thrombosis after discontinuation of vitamin K antagonist (VKA in SVT patients. Retrospective information from a cohort of SVT patients treated with VKA and followed by 37 Italian Anticoagulation Clinics, up to June 2013, was collected. Only patients who discontinued VKA and did not receive any other anticoagulant drug were enrolled in this study. Thrombotic events during follow-up were centrally adjudicated. Ninety patients were included: 33 unprovoked SVT, 27 SVT secondary to transient risk factors, and 30 with permanent risk factors. During a median follow-up of 1.6 years, 6 venous and 1 arterial thrombosis were documented, for an incidence of 3.3/100 patient-years (pt-y. The recurrence rate was highest in the first year after VKA discontinuation (8.2/100’pt-y and in patients with permanent risk factors (10.2/100’pt-y. Liver cirrhosis significantly increased the risk of recurrence. In conclusion, the rate of recurrent vascular complications after SVT is not negligible, at least in some patient subgroups.

  6. The incidence and characteristics of supraventricular tachycardia in left atrial isomerism: a high incidence of atrial fibrillation in young patients.

    Science.gov (United States)

    Miyazaki, Aya; Sakaguchi, Heima; Ohuchi, Hideo; Yamamoto, Tetsuya; Igarashi, Takehiro; Negishi, Jun; Toyota, Naoki; Kagisaki, Koji; Yagihara, Toshikatsu; Yamada, Osamu

    2013-06-20

    In left atrial isomerism (LAI), both atria show left atrial morphology. Although bradyarrhythmias are frequent and highly complex in LAI patients, previous studies have reported a low incidence of supraventricular tachycardia (SVT). To evaluate the incidence and characteristics of SVT in LAI, we retrospectively evaluated the clinical characteristics of SVTs in 83 patients with LAI (age at last follow-up, 15.3±10.5 years). There were 27 SVTs in 19 patients (23%), including nine episodes of atrial fibrillation (AF) and eight non-reentrant SVTs. Sixteen of the 19 patients with SVT had histories of atriotomy, but the three patients with AF or non-reentrant tachycardia had no history of atriotomy. The rates of freedom from SVT were 66% and 59% at ages of 20 and 30 years, respectively; the corresponding rates for freedom from AF were 89% and 74%. In multivariate analysis, the predictors of SVT were age (OR, 1.14; 95% CI, 1.06-1.26; p=0.003) and sinus node dysfunction (SND) (OR, 3.88; 95% CI, 1.57-13.34; p=0.01). In patients with LAI, SVTs are common, and AF and non-reentrant SVTs are the major type of SVTs. The incidence of AF was high in young patients with LAI. The lack of anatomical barriers in the atria that allow the formation of macro-reentrant circuits may account for the higher incidence of AF and non-reentrant SVT than macro-reentrant tachycardia. Moreover, the increasing prevalence of SND with age should contribute to a higher incidence of SVT. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Solution of closing of the columns of thermocouples in Asco reactors 1 and 2 with Cetna of Westinghouse; Solucion de cierre de las columnas de termopares en reactores Asco 1 and 2 con Cetna de Westinghouse

    Energy Technology Data Exchange (ETDEWEB)

    Sunjic, B.; Reichenbach, M.; Llibre, E.

    2014-10-01

    Occasionally, small leaks have been discovered in operating PWRs in the Thermo Couple columns Penetrations. In order to mitigate this issue, Westinghouse has designed and developed the CETNA element, which does not use cono-seals. This article shows the CETNA supply for Asco NPP to prevent potential leaks in the penetrations. (Author)

  8. First-year experience with the Ba Bar silicon vertex tracker

    International Nuclear Information System (INIS)

    Bozzi, C.; Carassiti, V.; Cotta Ramusino, A.; Dittongo, S.; Folegani, M.; Piemontese, L.; Abbott, B.K.; Breon, A.B.; Clark, A.R.; Dow, S.; Fan, Q.; Goozen, F.; Hernikl, C.; Karcher, A.; Kerth, L.T.; Kipnis, I.; Kluth, S.; Lynch, G.; Levi, M.; Luft, P.; Luo, L.; Nyman, M.; Pedrali-Noy, M.; Roe, N.A.; Zizka, G.; Roberts, D.; Schieck, J.; Barni, D.; Brenna, E.; Defendi, I.; Forti, A.; Giugni, D.; Lanni, F.; Palombo, F.; Vaniev, V.; Leona, A.; Mandelli, E.; Manfredi, P.F.; Perazzo, A.; Re, V.; Angelini, C.; Batignani, G.; Bettarini, S.; Bondioli, M.; Bosi, F.; Calderini, G.; Carpinelli, M.; Forti, F.; Gagliardi, D.; Giorgi, M.A.; Lusiani, A.; Mammini, P.; Morganti, M.; Morsani, F.; Neri, N.; Paoloni, E.; Profeti, A.; Rama, M.; Rampino, G.; Rizzo, G.; Sandrelli, F.; Simi, G.; Triggiani, G.; Tritto, S.; Vitale, R.; Walsh, J.; Burchat, P.; Cheng, C.; Kirkby, D.; Meyer, T.; Roat, C.; Bona, M.; Bianchi, F.; Daudo, F.; Di Girolamo, B.; Gamba, D.; Giraudo, G.; Grosso, P.; Romero, A.; Smol, A.; Trapani, P.; Zanin, D.; Bosisio, L.; Della Ricca, G.; Rashevskaia, I.; Lanceri, L.; Pompili, A.; Poropat, P.; Prest, M.; Rastelli, C.; Vallazza, E.; Vuagnin, G.; Hast, C.; Potter, E.P.; Sharma, V.; Burke, S.; Callahan, D.; Campagnari, C.; Dahmes, B.; Eppich, A.; Hale, D.; Hall, K.; Hart, P.; Kuznetsova, N.; Kyre, S.; Levy, S.; Long, O.; May, J.; Richman, J.; Verkerke, W.; Witherell, M.; Beringer, J.; Eisner, A.M.; Frey, A.; Grillo, A.; Grothe, M.; Johnson, R.; Kroeger, W.; Lockman, W.; Pulliam, T.; Rowe, W.; Schmitz, R.; Seiden, A.; Spencer, E.; Turri, M.; Walkowiak, W.; Wilder, M.; Charles, E.; Elmer, P.; Nielsen, J.; Orejudos, W.; Scott, I.; Zobernig, H.

    2001-01-01

    Within its first year of operation, the BaBar Silicon Vertex Tracker (SVT) has accomplished its primary design goal, measuring the z vertex coordinate with sufficient accuracy as to allow the measurement of the time-dependent CP asymmetry in the neutral B-meson system. The SVT consists of five layers of double-sided, AC-coupled silicon-strip detectors of 300 μm thickness with a readout strip pitch of 50-210 μm and a stereo angle of 90 deg. between the strips on the two sides. Detector alignment and performance with respect to spatial resolution and efficiency in the reconstruction of single hits are discussed. In the day-to-day operation of the SVT, radiation damage and protection issues were of primary concern. The SVT is equipped with a dedicated system (SVTRAD) for radiation monitoring and protection, using reverse-biased photodiodes. The evolution of the SVTRAD thresholds on the tolerated radiation level is described. Results on the first-year radiation exposure as measured with the SVTRAD system and on the so far accumulated damage are presented. The implications of test-irradiation results and possible future PEP-II luminosity upgrades on the radiation limited lifetime of the SVT are discussed

  9. Assessment of pathophysiology based on the left ventricular shape in five patients with midventricular obstructive hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Aoki, Mayumi; Uekita, Kazumi; Obata, Hiromi; Makiguchi, Noriko; Mitsuoka, Takao; Kikuchi, Kenjiro

    2007-01-01

    The pathophysiology of midventricular obstructive hypertrophic cardiomyopathy (MVO) is unknown. Patients with MVO and MVO-like cardiomyopathy were classified into three groups based on the cardioimaging morphological characteristics of the left ventricle to investigate their complications and treatment. Four patients with MVO and one patient with disease-like MVO were admitted in our hospital from 1999 to 2005. Group A consisted of one patient with indications of pressure gradient at mid-ventricle without apical aneurysm, Group B consisted of three patients with indications of pressure gradient and apical aneurysm, and Group C consisted of one patient with hour-glass appearance with apical aneurysm and decreased left ventricular systolic function without pressure gradient. The diagnosis was established during examination for sustained ventricular tachycardia (SVT, three patients), paroxysmal atrial fibrillation (one patient), and coronary artery disease (one patient). Cardiogenic embolization was observed in all cases which originated from atrial fibrillation (one case) and apical aneurysm (two cases). No embolic event occurred in any patient after warfarin therapy. SVT occurred in patients in Groups B and C. SVT refractory to beta-blocker and mexiletine was treated by amiodarone. Apical aneurysmectomy and cryoablation could prevent recurrent SVT with drug resistance. Four of the five patients with MVO had arrhythmia (atrial fibrillation, SVT) and three had cardiogenic embolization. MVO could be classified into three groups depending on the morphological characteristics and complications. Treatment of MVO should be based on these characteristics. (author)

  10. Utility of 12-lead electrocardiogram for differentiating paroxysmal supraventricular tachycardias in dogs.

    Science.gov (United States)

    Santilli, R A; Perego, M; Crosara, S; Gardini, F; Bellino, C; Moretti, P; Spadacini, G

    2008-01-01

    The 12-lead surface ECG is validated for differentiating supraventricular tachycardias (SVT) in humans. Despite the description of SVT in veterinary medicine, no studies have analyzed the electrocardiographic features of this type of arrhythmias in dogs. To describe the specific electrocardiographic criteria used to differentiate the most common SVT in dogs. Twenty-three dogs examined at Clinica Veterinaria Malpensa for SVT with the mechanism documented by electrophysiologic studies (EPS). Twelve-lead electrocardiographic variables obtained from 14 dogs with orthodromic atrioventricular reciprocating tachycardia (OAVRT) and 9 dogs with focal atrial tachycardia (FAT) were compared. Dogs with FAT had faster heart rates (278 +/- 62 versus 229 +/- 42 bpm; P= .049) and less QRS alternans (33 versus 86%; P= .022). P waves appeared during tachycardia in 22 dogs, with a superior axis in 100% of OAVRT and 22% of FAT (P < .001). OAVRT was characterized by a shorter RP interval (85.0 +/- 16.8 versus 157.1 +/- 37.3 ms; P < .001) and smaller RP/PR ratio (0.60 +/- 0.18 versus 1.45 +/- 0.52; P < .001). Repolarization anomalies were present in 64% of OAVRT and no FAT (P < .001). Multivariate analysis identified QRS alternans and a positive P wave in aVR during tachycardia as independent predictors of arrhythmia type. Electrocardiographic criteria used in people for differentiating SVT can also be applied in dogs.

  11. Characteristics and identification of sites of chagasic ventricular tachycardia by endocardial mapping

    Directory of Open Access Journals (Sweden)

    Távora Maria Zildany P.

    1999-01-01

    Full Text Available OBJECTIVE: To study electrophysiological characteristics that enable the identification and ablation of sites of chagasic tachycardia. METHODS: Thirty-one patients with chronic Chagas' heart disease and sustained ventricular tachycardia (SVT underwent electrophysiological study to map and ablate that arrhythmia. Fifteen patients had hemodinamically stable SVT reproducible by programmed ventricular stimulation, 9 men and 6 women with ages ranging from 37 to 67 years and ejection fraction varying from 0.17 to 0.64. Endocardial mapping was performed during SVT in all patients. Radiofrequency (RF current was applied to sites of presystolic activity of at least 30 ms. Entrainment was used to identify reentrant circuits. In both successful and unsuccessful sites of RF current application, electrogram and entrainment were analyzed. RESULTS: Entrainment was obtained during all mapped SVT. In 70.5% of the sites we observed concealed entrainment and ventricular tachycardia termination in the first 15 seconds of RF current application. In the unsuccessful sites, significantly earlier electrical activity was seen than in the successful ones. Concealed entrainment was significantly associated with ventricular tachycardia termination. Bystander areas were not observed. CONCLUSION: The reentrant mechanism was responsible for the genesis of all tachycardias. In 70.5% of the studied sites, the endocardial participation of the slow conducting zone of reentrant circuits was shown. Concealed entrainment was the main electrophysiological parameter associated with successful RF current application. There was no electrophysiological evidence of bystander regions in the mapped circuits of SVT.

  12. Recurrence of superficial vein thrombosis in patients with varicose veins.

    Science.gov (United States)

    Karathanos, Christos; Spanos, Konstantinos; Saleptsis, Vassileios; Tsezou, Aspasia; Kyriakou, Despina; Giannoukas, Athanasios D

    2016-08-01

    To investigate which factors other than history of superficial vein thrombosis (SVT) are associated with recurrent spontaneous SVT episodes in patients with varicose veins (VVs). Patients with a history of spontaneous SVT and VVs were followed up for a mean period of 55 months. Demographics, comorbidities, and thrombophilia screening test were analyzed. Patients were grouped according to the clinical-etiology-anatomy-pathophysiology classification. A multiple logistic regression analysis with the forward likelihood ratio method was undertaken. Thirteen patients out of 97 had a recurrence SVT episode during the follow-up period. All those patients were identified to have a thrombophilia defect. Protein C and S, antithrombin, and plasminogen deficiencies were more frequently present in patients without recurrence. Gene mutations were present in 38% in the nonrecurrence group and 77% in the recurrence group. After logistic regression analysis, patients with dislipidemia and mutation in prothrombin G20210A (FII) had an increased risk for recurrence by 5.4-fold and 4.6-fold, respectively. No deep vein thrombosis or pulmonary embolism occurred. Dislipidemia and gene mutations of F II are associated with SVT recurrence in patients with VVs. A selection of patients may benefit from anticoagulation in the short term and from VVs intervention in the long term. © The Author(s) 2015.

  13. The silicon vertex tracker for star and future applications of silicon drift detectors

    International Nuclear Information System (INIS)

    Bellwied, Rene

    2001-01-01

    The Silicon Vertex Tracker (SVT) for the STAR experiment at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory has recently been completed and installed. First data were taken in July 2001. The SVT is based on a novel semi-conductor technology called Silicon Drift Detectors. 216 large area (6 by 6 cm) Silicon wafers were employed to build a three barrel device capable of vertexing and tracking in a high occupancy environment. Its intrinsic radiation hardness, its operation at room temperature and its excellent position resolution (better than 20 micron) in two dimensions with a one dimensional detector readout, make this technology very robust and inexpensive and thus a viable alternative to CCD, Silicon pixel and Silicon strip detectors in a variety of applications from fundamental research in high-energy and nuclear physics to astrophysics to medical imaging. I will describe the development that led to the STAR-SVT, its performance and possible applications for the near future

  14. Image retrieval by information fusion based on scalable vocabulary tree and robust Hausdorff distance

    Science.gov (United States)

    Che, Chang; Yu, Xiaoyang; Sun, Xiaoming; Yu, Boyang

    2017-12-01

    In recent years, Scalable Vocabulary Tree (SVT) has been shown to be effective in image retrieval. However, for general images where the foreground is the object to be recognized while the background is cluttered, the performance of the current SVT framework is restricted. In this paper, a new image retrieval framework that incorporates a robust distance metric and information fusion is proposed, which improves the retrieval performance relative to the baseline SVT approach. First, the visual words that represent the background are diminished by using a robust Hausdorff distance between different images. Second, image matching results based on three image signature representations are fused, which enhances the retrieval precision. We conducted intensive experiments on small-scale to large-scale image datasets: Corel-9, Corel-48, and PKU-198, where the proposed Hausdorff metric and information fusion outperforms the state-of-the-art methods by about 13, 15, and 15%, respectively.

  15. An intelligent instrument for measuring exhaust temperature of marine engine

    Science.gov (United States)

    Ma, Nan-Qi; Su, Hua; Liu, Jun

    2006-12-01

    Exhaust temperature of the marine engine is commonly measured through thermocouple. Measure deviation will occur after using the thermocouple for some time due to nonlinearity of thermocouple itself, high temperature and chemical corrosion of measure point. Frequent replacement of thermocouple will increase the operating cost. This paper designs a new intelligent instrument for solving the above-mentioned problems of the marine engine temperature measurement, which combines the conventional thermocouple temperature measurement technology and SCM(single chip microcomputer). The reading of the thermocouple is simple and precise and the calibration can be made automatically and manually.

  16. Inappropriate shocks in the subcutaneous ICD

    DEFF Research Database (Denmark)

    Olde Nordkamp, Louise R A; Brouwer, Tom F; Barr, Craig

    2015-01-01

    shocks have been reported. METHODS: We analyzed the incidence, predictors and management of inappropriate shocks in the EFFORTLESS S-ICD Registry, which collects S-ICD implantation information and follow-up data from clinical centers in Europe and New Zealand. RESULTS: During a follow-up of 21 ± 13...... xyphoid to V6) reduced the risk. Reprogramming or optimization of SVT treatment after the first clinical event of inappropriate shock was successful in preventing further inappropriate shocks for cardiac oversensing and SVT events. CONCLUSIONS: Inappropriate shocks, mainly due to cardiac oversensing...

  17. Simulations of silicon vertex tracker for star experiment at RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Odyniec, G.; Cebra, D.; Christie, W.; Naudet, C.; Schroeder, L.; Wilson, W. [Lawrence Berkeley Lab., CA (United States); Liko, D. [Institut fur Hochenenergiephysik, Vienna, (Austria); Cramer, J.; Prindle, D.; Trainor, T. [Univ. of Washington, Seattle (United States); Braithwaite, W. [Univ. of Arkansas, Little Rock (United States)

    1991-12-31

    The first computer simulations to optimize the Silicon Vertex Tracker (SVT) designed for the STAR experiment at RHIC are presented. The physics goals and the expected complexity of the events at RHIC dictate the design of a tracking system for the STAR experiment. The proposed tracking system will consist of a silicon vertex tracker (SVT) to locate the primary interaction and secondary decay vertices and to improve the momentum resolution, and a time projection chamber (TPC), positioned inside a solenoidal magnet, for continuous tracking.

  18. Splanchnic vein thrombosis as a first manifestation of Primary myelofibrosis

    Science.gov (United States)

    Campos-Cabrera, Gregorio; Campos-Cabrera, Virginia; Campos-Cabrera, Salvador; Campos-Villagómez, José-Luis; Romero-González, Alejandra

    2017-01-01

    Myeloproliferative neoplasms are chronic disorders of clonal hematopoietic stem cells, characterized by an overproduction of functional granulocytes, red blood cells and / or platelets, and one of the major complications is the occurrence of venous and arterial thrombotic problems caused by increased platelet aggregation and thrombin generation. In this study 11 cases of primary myelofibrosis (PM) were evaluated and 2 debuted with splanchnic venous thrombosis (SVT); so after seeing the results of this study and of world literature, it is suggested that in patients with SVT, diagnostic methods for PM like the JAK2V617F mutation should be included. Copyright: © 2017 SecretarÍa de Salud

  19. The Effects of Thermal Barrier Coating, Common-Rail Injection, and Reduced Compression Ratio on the Efficiency of Single-Cylinder Diesel Engines

    Science.gov (United States)

    2010-05-12

    Omega Thermocouple ................................................................................................ 61 Figure 29: Omega Monogram Ten...Inter-Loc V Digital Multi-Loop Controller 61 Figure 28: Omega Thermocouple Figure 29: Omega Monogram Ten-Channel...instrument will be used. In this study the thermocouple voltage was converted to a temperature reading by a converter. A Monogram ten-channel

  20. Comparison of transplacental treatment of fetal supraventricular tachyarrhythmias with digoxin, flecainide, and sotalol: results of a nonrandomized multicenter study

    NARCIS (Netherlands)

    Jaeggi, Edgar T.; Carvalho, Julene S.; de Groot, Ernestine; Api, Olus; Clur, Sally-Ann B.; Rammeloo, Lukas; McCrindle, Brian W.; Ryan, Greg; Manlhiot, Cedric; Blom, Nico A.

    2011-01-01

    Fetal tachyarrhythmia may result in low cardiac output and death. Consequently, antiarrhythmic treatment is offered in most affected pregnancies. We compared 3 drugs commonly used to control supraventricular tachycardia (SVT) and atrial flutter (AF). We reviewed 159 consecutive referrals with fetal

  1. Antithrombotic Treatment of Splanchnic Vein Thrombosis : Results of an International Registry

    NARCIS (Netherlands)

    Ageno, Walter; Riva, Nicoletta; Bang, Soo-Mee; Sartori, Maria Teresa; Grandone, Elvira; Beyer-Westendorf, Jan; Barillari, Giovanni; Di Minno, Matteo N. D.; Duce, Rita; Malato, Alessandra; Santoro, Rita; Poli, Daniela; Verhamme, Peter; Martinelli, Ida; Kamphuisen, Pieter W.; Alatri, Adriano; Oh, Doyeun; Amico, Elbio D.; Schulman, Sam; Dentali, Francesco

    2012-01-01

    Background: Treatment of splanchnic vein thrombosis (SVT) is a clinical challenge due to heterogeneity of clinical presentations, increased bleeding risk and lack of evidences from clinical trials. We carried out an international registry aimed to describe current treatment strategies and factors

  2. Science Library of Test Items. Volume Twelve. Mastery Testing Programme. [Mastery Tests Series 4.] Tests M39-M50.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of tests 39 through 50 include: (39) using a code; (40) naming the parts of a microscope; (41) calculating density and predicting flotation; (42) estimating metric length; (43) using SI symbols; (44) using s=vt; (45) applying a novel theory; (46)…

  3. Masked hypertension and cardiac remodeling in middle-aged endurance athletes

    OpenAIRE

    Trachsel, Lukas; Carlen, Frederic; Brugger, Nicolas Jacques; Seiler, Christian; Wilhelm, Matthias

    2015-01-01

    OBJECTIVES: Extensive endurance training and arterial hypertension are established risk factors for atrial fibrillation. We aimed to assess the proportion of masked hypertension in endurance athletes and the impact on cardiac remodeling, mechanics, and supraventricular tachycardias (SVT). METHODS: Male participants of a 10-mile race were recruited and included if office blood pressure was normal (

  4. Relativistic heavy ion research

    International Nuclear Information System (INIS)

    1992-01-01

    Experimental work is reported on the following topics: transverse energy production in 10.7-GeV/c/u Au on Au collisions; first results on delta ray production and charged particle multiplicities with the Au beam at 10.7 GeV/c/A; preliminary studies on the feasibility of flow measurement with the E814 participant calorimeter; preliminary results from the E877 telescope; and low-p t baryon distribution in Si+Al, Pb collisions at the AGS. Then the status of the Hadronic Calorimeter project of AGS Experiment E864 (ECOS--Exotic Composite Object Spectrometer) is reviewed. Next, the same is done for work of the STAR RHIC collaboration (Silicon Vertex Tracker (SVT) project evolution and development in FY92, SVT software results from 1992, SVT instrumentation, FY93 SVT pion test beam). The instrumentation section deals with the design and installation of a target rapidity telescope for BNL experiment 814/877 and a repair scheme for the E814/E877 participant calorimeter. Finally, the theory part addresses bosonic kinetics: thermalization of mesons and the pion p perpendicular spectrum in ultrarelativistic heavy-ion collisions and non-equilibrium properties of hadronic mixtures

  5. Determination of Delta m(d) and absolute calibration of flavor taggers for the Delta m(s) analysis, in fully reconstructed decays at the CDF experiment

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Jonatan Piedra [University of Cantabria, (Spain). Inst. of Physics

    2005-04-21

    The new trigger processor, the Silicon Vertex Tracking (SVT), has dramatically improved the B physics capabilities of the upgraded CDF II Detector; for the first time in a hadron collider, the SVT has enabled the access to non-lepton-triggered B meson decays. Within the new available range of decay modes, the B$0\\atop{s}$ → D$-\\atop{s}$π+ signature is of paramount importance in the measurement of the Δms mixing frequency. The analysis reported here is a step towards the measurement of this frequency; two where our goals: carrying out the absolute calibration of the opposite side flavor taggers, used in the Δms measurement; and measuring the B$0\\atop{d}$ mixing frequency in a B → Dπ sample, establishing the feasibility of the mixing measurement in this sample whose decay-length is strongly biased by the selective SVT trigger. We analyze a total integrated luminosity of 355 pb-1 collected with the CDF II Detector. By triggering on muons, using the conventional di-muon trigger; or displaced tracks, using the SVT trigger, we gather a sample rich in bottom and charm mesons.

  6. Identification of blast resistance expression in rice genotypes using ...

    African Journals Online (AJOL)

    USER

    2010-06-14

    Jun 14, 2010 ... for pyramid resistance genes because the presence of one major gene ... of inoculums. Standard agronomic management practices were .... CSR-27. 80.00 ± 4.46. 85.00 ± 4.62. 2062.50 ± 192.25. 2098.81 ± 193.18. SVT-10.

  7. Clinical utility of the Neurobehavioral Symptom Inventory validity scales to screen for symptom exaggeration following traumatic brain injury.

    Science.gov (United States)

    Lange, Rael T; Brickell, Tracey A; Lippa, Sara M; French, Louis M

    2015-01-01

    The purpose of this study was to examine the clinical utility of three recently developed validity scales (Validity-10, NIM5, and LOW6) designed to screen for symptom exaggeration using the Neurobehavioral Symptom Inventory (NSI). Participants were 272 U.S. military service members who sustained a mild, moderate, severe, or penetrating traumatic brain injury (TBI) and who were evaluated by the neuropsychology service at Walter Reed Army Medical Center within 199 weeks post injury. Participants were divided into two groups based on the Negative Impression Management scale of the Personality Assessment Inventory: (a) those who failed symptom validity testing (SVT-fail; n = 27) and (b) those who passed symptom validity testing (SVT-pass; n = 245). Participants in the SVT-fail group had significantly higher scores (pscales (range: d = 0.76 to 2.34). Similarly high sensitivity, specificity, positive predictive power (PPP), and negative predictive (NPP) values were found when using all three validity scales to differentiate SVT-fail versus SVT-pass groups. However, the Validity-10 scale consistently had the highest overall values. The optimal cutoff score for the Validity-10 scale to identify possible symptom exaggeration was ≥19 (sensitivity = .59, specificity = .89, PPP = .74, NPP = .80). For the majority of people, these findings provide support for the use of the Validity-10 scale as a screening tool for possible symptom exaggeration. When scores on the Validity-10 exceed the cutoff score, it is recommended that (a) researchers and clinicians do not interpret responses on the NSI, and (b) clinicians follow up with a more detailed evaluation, using well-validated symptom validity measures (e.g., Minnesota Multiphasic Personality Inventory-2 Restructured Form, MMPI-2-RF, validity scales), to seek confirmatory evidence to support an hypothesis of symptom exaggeration.

  8. Very High Output Thermoelectric Devices Based on ITO Nanocomposites

    Science.gov (United States)

    Fralick, Gustave; Gregory, Otto J.

    2009-01-01

    A material having useful thermoelectric properties was synthesized by combining indium-tin-oxide (ITO) with a NiCoCrAlY alloy/alumina cermet. This material had a very large Seebeck coefficient with electromotive-force-versustemperature behavior that is considered to be excellent with respect to utility in thermocouples and other thermoelectric devices. When deposited in thin-film form, ceramic thermocouples offer advantages over precious-metal (based, variously, on platinum or rhodium) thermocouples that are typically used in gas turbines. Ceramic thermocouples exhibit high melting temperatures, chemical stability at high temperatures, and little or no electromigration. Oxide ceramics also resist oxidation better than metal thermocouples, cost substantially less than precious-metal thermocouples, and, unlike precious-metal thermocouples, do not exert catalytic effects.

  9. Designing an accurate system for temperature measurements

    Directory of Open Access Journals (Sweden)

    Kochan Orest

    2017-01-01

    Full Text Available The method of compensation of changes in temperature field along the legs of inhomogeneous thermocouple, which measures a temperature of an object, is considered in this paper. This compensation is achieved by stabilization of the temperature field along the thermocouple. Such stabilization does not allow the error due to acquired thermoelectric inhomogeneity to manifest itself. There is also proposed the design of the furnace to stabilize temperature field along the legs of the thermocouple which measures the temperature of an object. This furnace is not integrated with the thermocouple mentioned above, therefore it is possible to replace this thermocouple with a new one when it get its legs considerably inhomogeneous.. There is designed the two loop measuring system with the ability of error correction which can use simultaneously a usual thermocouple as well as a thermocouple with controlled profile of temperature field. The latter can be used as a reference sensor for the former.

  10. Does prostate brachytherapy treat the seminal vesicles? A dose-volume histogram analysis of seminal vesicles in patients undergoing combined PD-103 prostate implantation and external beam irradiation

    International Nuclear Information System (INIS)

    Stock, Richard G.; Lo, Yeh-Chi; Gaildon, Mohamoud; Stone, Nelson N.

    1999-01-01

    Purpose: Combined brachytherapy of the prostate and external beam irradiation (EBRT) of the prostate and seminal vesicles (SV) is becoming a popular treatment for high-risk prostate cancer. Dose-volume histogram (DVH) analysis of the SV in patients undergoing this treatment was performed to determine the dose distribution to the SV and the adequacy of this treatment in patients with potential SV involvement. Methods and Materials: Twenty-five consecutive patients were treated with a Pd-103 implant of the prostate alone and 45 Gy of EBRT to the prostate and SV. Attempts were not made to implant the SV but seeds were routinely placed at the junction of the prostate and SV. All patients underwent CT-based post implant dosimetric analysis 1 month after implantation. As part of this analysis, DVH were generated for the prostate and total SV volume (SVT). In addition, the SV was divided into 6-mm-thick volumes identified as SV1, SV2, SV3, SV4, and SV5 starting from the junction of the prostate and SV and extending distally. DVH were also generated for these structures. Delivered dose was defined as the D90 (dose delivered to 90% of the organ on DVH). Results: The median volumes in cc of the prostate, SVT, SV1, SV2, SV3, SV4, and SV5 were 34.33, 9.75, 2.7, 3.48, 2.92, 3.18, and 1.96 respectively. The SVT contained from 0-9 seeds (median 2). There was little dose delivered to the SVT and SV volumes from the implanted prostate. The median D90 values for the prostate, SVT, SV1, SV2, SV3, SV4, and SV5 were 8615 cGy, 675 cGy, 3100 cGy, 1329 cGy, 553 cGy, 246 cGy, and 67 cGy, respectively. The dose delivered to the prostate covered small percentages of SV. The percents of SV volumes covered by the prostate D90 were 11, 35, 3.3, 0, 0, and 0 for SVT, SV1, SV2, SV3, SV4, and SV5, respectively. Conclusions: DVH analysis of the SV reveals that dose generated from an implanted prostate contributes little to the SV. Those patients at high risk for SV involvement may be under treated

  11. Electroconvulsive therapy in patients with cardiac pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Dolenc, Tamara J; Barnes, Roxann D; Hayes, David L; Rasmussen, Keith G

    2004-09-01

    Electroconvulsive therapy (ECT) is used to treat major depressive illness, especially in elderly and medically frail patients. Not uncommonly, these patients have cardiac pacemakers or implantable cardioverter defibrillators (ICDs). Only a few case reports in the literature describe the use of ECT in such patients. Herein we review our ECT experience treating 26 pacemaker patients and 3 ICD patients. All patients obtained significant antidepressant benefits with ETC. Only one serious cardiac event occurred, a case of supraventricular tachycardia (SVT) requiring a stay on the cardiac intensive care unit. The SVT resolved and the patient went on to receive further uncomplicated ECT treatments. We conclude from this experience that with proper pre-ECT cardiac and pacemaker/defibrillator assessment, ECT can be safely and effectively administered to patients with an implanted cardiac device.

  12. Using intraindividual variability to detect malingering in cognitive performance.

    Science.gov (United States)

    Strauss, E; Hultsch, D F; Hunter, M; Slick, D J; Patry, B; Levy-Bencheton, J

    1999-11-01

    The utility of measures for detecting malingering was evaluated using a simulation design in which half the participants were encouraged to do their best and half were asked to feign head injury. Particular attention was focused on the utility of repeated assessment (intraindividual variability) in discriminating the groups. Participants were tested on three occasions on measures commonly used to detect malingering including a specific symptom validity test (SVT). The results indicated that multiple measures of malingering obtained in single assessment (occasion one) discriminated the groups effectively. In addition, however, intraindividual variability in performance, particularly of indicators from the SVT, provided unique information beyond level of performance. The results suggest that response inconsistency across testing sessions may be a clinically useful measure for the detection of malingering.

  13. The CDF online Silicon Vertex Tracker

    International Nuclear Information System (INIS)

    Ashmanskas, W.; Bardi, A.; Bari, M.; Belforte, S.; Berryhill, J.; Bogdan, M.; Carosi, R.; Cerri, A.; Chlachidze, G.; Culbertson, R.; Dell'Orso, M.; Donati, S.; Fiori, I.; Frisch, H.J.; Galeotti, S.; Giannetti, P.; Glagolev, V.; Moneta, L.; Morsani, F.; Nakaya, T.; Passuello, D.; Punzi, G.; Rescigno, M.; Ristori, L.; Sanders, H.; Sarkar, S.; Semenov, A.; Shochet, M.; Speer, T.; Spinella, F.; Wu, X.; Yang, U.; Zanello, L.; Zanetti, A.M.

    2002-01-01

    The CDF Online Silicon Vertex Tracker (SVT) reconstructs 2D tracks by linking hit positions measured by the Silicon Vertex Detector to the Central Outer Chamber tracks found by the eXtremely Fast Tracker (XFT). The system has been completely built and assembled and it is now being commissioned using the first CDF run II data. The precision measurement of the track impact parameter will allow triggering on B hadron decay vertices and thus investigating important areas in the B sector, like CP violation and B s mixing. In this paper we briefly review the architecture and the tracking algorithms implemented in the SVT and we report on the performance of the system achieved in the early phase of CDF run II

  14. Dynamic one-dimensional modeling of secondary settling tanks and system robustness evaluation.

    Science.gov (United States)

    Li, Ben; Stenstrom, M K

    2014-01-01

    One-dimensional secondary settling tank models are widely used in current engineering practice for design and optimization, and usually can be expressed as a nonlinear hyperbolic or nonlinear strongly degenerate parabolic partial differential equation (PDE). Reliable numerical methods are needed to produce approximate solutions that converge to the exact analytical solutions. In this study, we introduced a reliable numerical technique, the Yee-Roe-Davis (YRD) method as the governing PDE solver, and compared its reliability with the prevalent Stenstrom-Vitasovic-Takács (SVT) method by assessing their simulation results at various operating conditions. The YRD method also produced a similar solution to the previously developed Method G and Enquist-Osher method. The YRD and SVT methods were also used for a time-to-failure evaluation, and the results show that the choice of numerical method can greatly impact the solution. Reliable numerical methods, such as the YRD method, are strongly recommended.

  15. Neonatal thyrotoxicosis with severe supraventricular tachycardia: case report and review of the literature.

    Science.gov (United States)

    Abbasoğlu, Aslıhan; Ecevit, Ayşe; Tuğcu, Ali Ulaş; Erdoğan, Lkay; Kınık, Sibel Tulgar; Tarcan, Aylin

    2015-03-01

    Neonatal thyrotoxicosis is a rare condition caused by the transplacental passage of thyroid stimulating immunoglobulins from mothers with Graves' disease. We report a case of neonatal thyrotoxicosis with concurrent supraventricular tachycardia (SVT). The female infant, who was born by section due to breech delivery and meconium in the amniotic fluid at 36 weeks of gestation, presented with tachycardia on day 7. Her heart rate was between 260 and 300 beats/min, and an electrocardiogram revealed ongoing SVT. Sotalol was effective after two cardioversions in maintaining sinus rhythm. Thyroid function studies revealed hyperthyroidism in the infant, and her mother was found to have Graves' disease. Since symptoms and signs can vary, especially in preterm infants with neonatal hyperthyroidism, we want to emphasize the importance of prenatal care and follow-ups of Graves' disease associated pregnancies and management of newborns after birth.

  16. Neurocardiogenic Syncope and Supraventricular Tachycardia in Association with a Rare Congenital Aortic Valve Abnormality

    Directory of Open Access Journals (Sweden)

    Yashwant Agrawal

    2016-01-01

    Full Text Available We report a case of a 26-year-old woman who presented with multiple episodes of syncope over a five-months period of time. Transthoracic echocardiogram had shown a normal functioning quadricuspid aortic valve (QAV which was also confirmed on a transesophageal echocardiogram. Computed tomographic angiography of heart and coronary arteries showed the QAV with equal size of all aortic cusps and normal coronary arteries. Intermittent chest pain and palpitations warranted an exercise stress test. The stress test revealed normal aerobic exertion, with achievement of 101% of maximal peak heart rate. However, during peak stress, we noted a drop in her blood pressure significantly resulting in dizziness. No arrhythmias were noted during the stress test. With recurrent syncope episodes and palpitations, Holter monitoring was done, revealing supraventricular tachycardia (SVT. We discuss current available literature and coassociations with QAV. New association of QAV with SVT needs further analysis.

  17. An Unusual Cause of Supraventricular Tachycardia: Acute Carbon Monoxide Poisoning

    Directory of Open Access Journals (Sweden)

    Suat Zengin

    2014-03-01

    Full Text Available      Carbon monoxide (CO is a toxic gas produced by the incomplete combustion of carbon-containing compounds. Exposure to high concentrations of CO can be letha and is the most common cause of death from poisoning worldwide. Cardiac manifestations after exposure to CO, including myocardial ischemia, heart failure, and arrhythmias, have been reported. A 28-year-old a patient was admitted to our emergency department with altered consciousness as a consequence of acute domestic exposure to CO from a stove. His carboxyhemoglobin level was 39%. The oxygen treatment was started promptly, and therapeutic red cell exchange was performed. An electrocardiogram revealed supraventricular tachycardia (SVT, and an echocardiographic examination demonstrated normal cardiac functions. To the best of our knowledge, this study is the second to report a case of SVT attack due to acute CO intoxication. This paper discusses the management of this complication in patients poisoned with CO.

  18. Reference calorimeter for radiation monitoring

    International Nuclear Information System (INIS)

    Zajic, V.; Vanek, V.

    1978-01-01

    The miniature sensor for gamma dose rate monitoring in nuclear reactors essentially consists of an absorption body symmetrically placed in a gas-tight sealed case and suspended on a metal pull-rod attached to the jacketed thermocouple bushing. The inner thermocouple is inserted into the centre of the absorption body through a slant port while the outer thermocouple is let out of the case at a point above the absorption body. (J.P.)

  19. Apparatus Would Measure Temperatures Of Ball Bearings

    Science.gov (United States)

    Gibson, John C.; Fredricks, Thomas H.

    1995-01-01

    Rig for testing ball bearings under radial and axial loads and measuring surface temperatures undergoing development. Includes extensible thermocouples: by means of bellows as longitudinal positioners, thermocouples driven into contact with bearing balls to sense temperatures immediately after test run. Not necessary to disassemble rig or to section balls to obtain indirect indications of maximum temperatures reached. Thermocouple measurements indicate temperatures better than temperature-sensitive paints.

  20. Visceral Thromboses in Pancreas Adenocarcinoma: Systematic Review.

    Science.gov (United States)

    Hicks, Angel Mier; DeRosa, Antonio; Raj, Micheal; Do, Richard; Yu, Kenneth H; Lowery, Maeve A; Varghese, Anna; O'Reilly, Eileen M

    2017-12-12

    Within gastrointestinal malignancies, primary hepatocellular carcinoma and pancreatic ductal adenocarcinoma (PDAC) are frequently associated with visceral thromboses (VT). Thrombus formation in the portal (PVT), mesenteric (MVT), or splenic vein (SVT) system leads to portal hypertension and intestinal ischemia. VT in PDAC may convey a risk of increased distal thrombosis and poses therapeutic uncertainty regarding the role of anticoagulation. An increasing number of reports describe VT associated with PDAC. It is possible that early diagnosis of these events may help reduce morbidity and speculatively improve oncologic outcomes. To perform a systematic review to study PVT, MVT, and SVT associated with PDAC, and to provide a comprehensive review. Medline/PubMed, Embase, Web of Science, Scopus, and the Cochrane Library. Data Extraction and Assessment: Two blinded independent observers extracted and assessed the studies for diagnosis of PVT, MVT, and SVT in PDAC. Studies were restricted to English-language literature published between 2007 and 2016. Eleven articles were identified. Five case reports and 7 retrospective studies were found, with a total of 127 patients meeting the inclusion criteria. The mean age at diagnosis was 64 years. PVT was found in 35% (n = 46), SVT in 52% (n = 65), and MVT in 13% (n = 15). Mean follow-up time was 26 months. Only 3 of the selected articles studied the impact of anticoagulation in VT. All patients with nonvisceral thrombosis (eg, deep-vein thrombosis, pulmonary emboli) were therapeutically treated; in contrast, patients with VT only rarely received treatment. VT in PDAC is a frequent finding at diagnosis or during disease progression. Evidence to guide treatment choices is limited, and current management is based on inferred experience from nononcologic settings. Anticoagulation appears to be safe in VT, with most of the large studies recommending a careful assessment for patients at a high risk of bleeding. Copyright © 2017

  1. Identifying an evidence-based model of therapy for the pre-hospital emergency management of supraventricular tachycardia

    OpenAIRE

    Smith, Gavin

    2017-01-01

    This thesis provides a comprehensive reporting of the work undertaken to identify evidence supporting pre-hospital management of supraventricular tachycardia (SVT), delivering an evidence base for paramedic treatment of these patients. The literature search identified absences in evidence supporting therapies used within existing clinical guidelines. The vagal manoeuvres, the simplest and least invasive therapy to employ in the stable patient, were insufficiently evidenced regarding technique...

  2. Safety and efficacy of ruxolitinib in splanchnic vein thrombosis associated with myeloproliferative neoplasms.

    Science.gov (United States)

    Pieri, Lisa; Paoli, Chiara; Arena, Umberto; Marra, Fabio; Mori, Fabio; Zucchini, Mery; Colagrande, Stefano; Castellani, Alessandro; Masciulli, Arianna; Rosti, Vittorio; De Stefano, Valerio; Betti, Silvia; Finazzi, Guido; Ferrari, Maria Luisa; Rumi, Elisa; Ruggeri, Marco; Nichele, Ilaria; Guglielmelli, Paola; Fjerza, Rajmonda; Mannarelli, Carmela; Fanelli, Tiziana; Merli, Lucia; Corbizi Fattori, Giuditta; Massa, Margherita; Cimino, Giuseppe; Rambaldi, Alessandro; Barosi, Giovanni; Cazzola, Mario; Barbui, Tiziano; Vannucchi, Alessandro M

    2017-02-01

    Splanchnic vein thrombosis (SVT) is one of the vascular complications of myeloproliferative neoplasms (MPN). We designed a phase 2 clinical trial to evaluate safety and efficacy of ruxolitinib in reducing splenomegaly and improving disease-related symptoms in patients with MPN-associated SVT. Patients diagnosed with myelofibrosis (12 cases), polycythemia vera (5 cases) and essential thrombocythemia (4 cases) received ruxolitinib for 24 weeks in the core study period. Spleen volume was assessed by magnetic resonance imaging (MRI) and splanchnic vein circulation by echo-Doppler analysis. Nineteen patients carried JAK2V617F, one had MPLW515L, and one CALRL367fs*46 mutation. Eighteen patients had spleno-portal-mesenteric thrombosis, two had Budd-Chiari syndrome, and one had both sites involved; 16 patients had esophageal varices. Ruxolitinib was well tolerated with hematological toxicities consistent with those of patients without SVT and no hemorrhagic adverse events were recorded. After 24 weeks of treatment, spleen volume reduction ≥35% by MRI was achieved by 6/21 (29%) patients, and a ≥50% spleen length reduction by palpation at any time up to week 24 was obtained by 13/21 (62%) patients. At week 72, 8 of the 13 (62%) patients maintained the spleen response by palpation. No significant effect of treatment on esophageal varices or in splanchnic circulation was observed. MPN-related symptoms, evaluated by MPN-symptom assessment form (SAF) TSS questionnaire, improved significantly during the first 4 weeks and remained stable up to week 24. In conclusion, this trial shows that ruxolitinib is safe in patients with MPN-associated SVT, and effective in reducing spleen size and disease-related symptoms. © 2016 Wiley Periodicals, Inc.

  3. Is identity per se irrelevant? A contrarian view of self-verification effects

    OpenAIRE

    Gregg, Aiden P.

    2008-01-01

    Self-verification theory (SVT) posits that people who hold negative self-views, such as depressive patients, ironically strive to verify that these self-views are correct, by actively seeking out critical feedback or interaction partners who evaluate them unfavorably. Such verification strivings are allegedly directed towards maximizing subjective perceptions of prediction and control. Nonetheless, verification strivings are also alleged to stabilize maladaptive self-perceptions, and thereby ...

  4. Transport and solid state battery characteristic studies of silver based super ion conducting glasses

    International Nuclear Information System (INIS)

    Jayaseelan, S.; Muralidharan, P.; Venkateswarlu, M.; Satyanarayana, N.

    2005-01-01

    Silverarsenotellurite (SAT), silverphosphotellurite (SPT) and silvervanadotellurite (SVT) quaternary glass systems were prepared with various formers compositions by a melt quenching method. Glass nature, glass transition temperature (T g ) and structure of the prepared glasses were identified respectively by X-ray diffraction (XRD), differential scanning calorimetric (DSC) and Fourier transform infrared (FT-IR) technique. Electrical conductivity studies were carried out by impedance measurement in the frequency range 40 Hz to 100 KHz at different temperatures for all three sets of AgI-Ag 2 O-[TeO 2 -M 2 O 5 ] (M 2 O 5 = As 2 O 5 , P 2 O 5 , V 2 O 5 ) glasses. The high conducting compositions of SAT, SPT and SVT glass samples were fixed from the results of total conductivity (σ t ). Electronic conductivity (σ e ) studies were made on high conducting composition of each glass system by Wagner's polarization method. Total current (i t ) is due to ion and electron. Electronic current (i e ) due to electron were estimated through mobility studies. Ionic conductivity (σ i ) and ionic current (i i ) were calculated respectively using the conductivity (σ t and σ e ) and current (i t and i e ) results for the SAT, SPT and SVT glasses. Transport numbers due to ion (t i ) and electron (t e ) were calculated using the conductivity and mobility results for each glass system. The high conducting composition of the SAT, SPT and SVT glasses were used as solid electrolytes with silver metal as an anode and iodine:graphite (I:C) as a cathode for the fabrication of solid state batteries (SSBs). All the fabricated batteries were characterized by measuring the open circuit voltage (OCV) and polarization properties and estimated the batteries performances

  5. Masked hypertension and cardiac remodeling in middle-aged endurance athletes.

    Science.gov (United States)

    Trachsel, Lukas D; Carlen, Frederik; Brugger, Nicolas; Seiler, Christian; Wilhelm, Matthias

    2015-06-01

    Extensive endurance training and arterial hypertension are established risk factors for atrial fibrillation. We aimed to assess the proportion of masked hypertension in endurance athletes and the impact on cardiac remodeling, mechanics, and supraventricular tachycardias (SVT). Male participants of a 10-mile race were recruited and included if office blood pressure was normal (hypertension and normotension group by ambulatory blood pressure. Primary endpoint was diastolic function, expressed as peak early diastolic mitral annulus velocity (E'). Left ventricular global strain, left ventricular mass/volume ratio, left atrial volume index, signal-averaged P-wave duration (SAPWD), and SVT during 24-h Holter monitoring were recorded. From 108 runners recruited, 87 were included in the final analysis. Thirty-three (38%) had masked hypertension. The mean age was 42 ± 8 years. Groups did not differ with respect to age, body composition, cumulative training hours, and 10-mile race time. Athletes with masked hypertension had a lower E' and a higher left ventricular mass/volume ratio. Left ventricular global strain, left atrial volume index, SAPWD, and SVT showed no significant differences between the groups. In multiple linear regression analysis, masked hypertension was independently associated with E' (beta = -0.270, P = 0.004) and left ventricular mass/volume ratio (beta = 0.206, P = 0.049). Cumulative training hours was the only independent predictor for left atrial volume index (beta = 0.474, P hypertension, associated with a lower diastolic function and a higher left ventricular mass/volume ratio, but unrelated to left ventricular systolic function, atrial remodeling, or SVT.

  6. Analog front-end for pixel sensors in a 3D CMOS technology for the SuperB Layer0

    International Nuclear Information System (INIS)

    Manazza, A.; Gaioni, L.; Re, V.

    2011-01-01

    This work is concerned with the design of two different analog channels for hybrid and monolithic pixels readout in view of applications to the SVT at the SuperB Factory. The circuits have been designed in a 130nm CMOS, vertically integrated technology, which, among others, may provide some advantages in terms of functional density and electrical isolation between the analog and the digital sections of the front-end.

  7. The BaBar silicon vertex tracker

    International Nuclear Information System (INIS)

    Bozzi, C.; Carassiti, V.; Ramusino, A. Cotta; Dittongo, S.; Folegani, M.; Piemontese, L.; Abbott, B.K.; Breon, A.B.; Clark, A.R.; Dow, S.; Fan, Q.; Goozen, F.; Hernikl, C.; Karcher, A.; Kerth, L.T.; Kipnis, I.; Kluth, S.; Lynch, G.; Levi, M.; Luft, P.; Luo, L.; Nyman, M.; Pedrali-Noy, M.; Roe, N.A.; Zizka, G.; Roberts, D.; Barni, D.; Brenna, E.; Defendi, I.; Forti, A.; Giugni, D.; Lanni, F.; Palombo, F.; Vaniev, V.; Leona, A.; Mandelli, E.; Manfredi, P.F.; Perazzo, A.; Re, V.; Angelini, C.; Batignani, G.; Bettarini, S.; Bondioli, M.; Bosi, F.; Calderini, G.; Carpinelli, M.; Dutra, F.; Forti, F.; Gagliardi, D.; Giorgi, M.A.; Lusiani, A.; Mammini, P.; Morganti, M.; Morsani, F.; Paoloni, E.; Profeti, A.; Rama, M.; Rampino, G.; Rizzo, G.; Sandrelli, F.; Simi, G.; Triggiani, G.; Tritto, S.; Vitale, R.; Burchat, P.; Cheng, C.; Kirkby, D.; Meyer, T.; Roat, C.; Bona, M.; Bianchi, F.; Daudo, F.; Girolamo, B. Di; Gamba, D.; Giraudo, G.; Grosso, P.; Romero, A.; Smol, A.; Trapani, P.; Zanin, D.; Bosisio, L.; Ricca, G. Della; Lanceri, L.; Pompili, A.; Poropat, P.; Prest, M.; Rastelli, C.; Vallazza, E.; Vuagnin, G.; Hast, C.; Potter, E.P.; Sharma, V.; Burke, S.; Callahan, D.; Campagnari, C.; Dahmes, B.; Eppich, A.; Hale, D.; Hall, K.; Hart, P.; Kuznetsova, N.; Kyre, S.; Levy, S.; Long, O.; May, J.; Richman, J.; Verkerke, W.; Witherell, M.; Beringer, J.; Eisner, A.M.; Frey, A.; Grillo, A.; Grothe, M.; Johnson, R.; Kroeger, W.; Lockman, W.; Pulliam, T.; Rowe, W.; Schmitz, R.; Seiden, A.; Spencer, E.; Turri, M.; Wilder, M.; Charles, E.; Elmer, P.; Nielsen, J.; Orejudos, W.; Scott, I.; Walsh, J.; Zobernig, H.

    2000-01-01

    The BaBar Silicon Vertex Tracker (SVT) is designed to provide the high-precision vertexing necessary for making measurements of CP violation at the SLAC B-Factory PEP-II. The instrument consists of five layers of double-sided silicon strip detectors and has been installed in the BaBar experiment and taking colliding beam data since May 1999. An overview of the design as well as performance and experience from the initial running will be presented

  8. 2259-IJBCS-Article-Bazouma Koulibaly

    African Journals Online (AJOL)

    hp

    4Unité de Formation des Sciences de la Vie et de la Terre (UFR/SVT), Laboratoire de Biologie et Ecologie. Végétale .... électrode en verre, selon un rapport ..... Impact des graminées sur une ressource rare : l'azote. In La Jachère en Afrique. Tropicale, Floret Ch, Pontanier R (eds). John Libbey Eurotext, Paris, 189-193.

  9. Intelligent classification of electrocardiogram (ECG) signal using extended Kalman Filter (EKF) based neuro fuzzy system.

    Science.gov (United States)

    Meau, Yeong Pong; Ibrahim, Fatimah; Narainasamy, Selvanathan A L; Omar, Razali

    2006-05-01

    This study presents the development of a hybrid system consisting of an ensemble of Extended Kalman Filter (EKF) based Multi Layer Perceptron Network (MLPN) and a one-pass learning Fuzzy Inference System using Look-up Table Scheme for the recognition of electrocardiogram (ECG) signals. This system can distinguish various types of abnormal ECG signals such as Ventricular Premature Cycle (VPC), T wave inversion (TINV), ST segment depression (STDP), and Supraventricular Tachycardia (SVT) from normal sinus rhythm (NSR) ECG signal.

  10. Hydrogen gas detector

    International Nuclear Information System (INIS)

    Bohl, T.L.

    1982-01-01

    A differential thermocouple hydrogen gas detector has one thermocouple junction coated with an activated palladium or palladium-silver alloy catalytic material to allow heated hydrogen gas to react with the catalyst and raise the temperature of that junction. The other juction is covered with inert glass or epoxy resin, and does not experience a rise in temperature in the presence of hydrogen gas. A coil heater may be mounted around the thermocouple junctions to heat the hydrogen, or the gas may be passed through a heated block prior to exposing it to the thermocouples

  11. Temperature measurement on Zircaloy-clad fuel pins during high temperature excursions

    International Nuclear Information System (INIS)

    Meservey, R.H.

    1976-04-01

    The development of a sheathed thermocouple suitable for attachment to zircaloy-clad fuel rods and for use during high temperature (2,800 0 F) excursions under loss-of-coolant accident conditions is described. Development, fabrication, and testing of the thermocouples is covered in detail. In addition, the development of a process for laser welding the thermocouples to fuel rods is discussed. The thermocouples and attachment welds have been tested for resistance to corrosion and nuclear radiation and have been subjected to fast thermal cycle, risetime, and blowdown accident tests

  12. Error handling for the CDF online silicon vertex tracker

    CERN Document Server

    Bari, M; Cerri, A; Dell'Orso, Mauro; Donati, S; Galeotti, S; Giannetti, P; Morsani, F; Punzi, G; Ristori, L; Spinella, F; Zanetti, A M

    2001-01-01

    The online silicon vertex tracker (SVT) is composed of 104 VME 9U digital boards (of eight different types). Since the data output from the SVT (few MB/s) are a small fraction of the input data (200 MB/s), it is extremely difficult to track possible internal errors by using only the output stream. For this reason, several diagnostic tools have been implemented: local error registers, error bits propagated through the data streams, and the Spy Buffer system. Data flowing through each input and output stream of every board are continuously copied to memory banks named spy buffers, which act as built-in logic state analyzers hooked continuously to internal data streams. The contents of all buffers can be frozen at any time (e.g., on error detection) to take a snapshot of all data flowing through each SVT board. The spy buffers are coordinated at system level by the Spy Control Board. The architecture, design, and implementation of this system are described. (4 refs).

  13. The anatomic basis for the acquisition of speech and obstructive sleep apnea: evidence from cephalometric analysis supports The Great Leap Forward hypothesis.

    Science.gov (United States)

    Davidson, Terence M; Sedgh, Jacob; Tran, Duyen; Stepnowsky, Carl J

    2005-11-01

    We previously postulated how evolutionary changes in man's upper respiratory tract to facilitate speech, a phenomenon Jared Diamond calls The Great Leap Forward, have predisposed man to obstructive sleep apnea (OSA) [Diamond J. The Third Chimpanzee: the evolution and future of the human animal. New York: HarperCollins Publishers; 1992. p. 21, 23, 32-54, 54-6; Davidson TM. The Great Leap Forward: the anatomic evolution of obstructive sleep apnea. Sleep Medicine 2003;4:185-94]. We grouped these anatomic changes into four categories: klinorynchy, laryngeal descent, craniobase angulation and supralaryngeal vocal tract (SVT) ratio of SVT(H):SVT(V). This study was designed to investigate the relationship between cephalometric measures corresponding to these anatomic changes and OSA. One hundred and twenty-three male subjects presenting with symptoms of OSA underwent unattended multi-channel home sleep studies. We obtained cephalometric measurements from standard lateral cephalograms. Pearson correlation coefficients were calculated between cephalometrics and apnea-hypopnea index (AHI), age, and body mass index (BMI). Our results showed significant correlation between AHI and klinorynchy, laryngeal descent, and craniobase angulation. Overall, our data supports the theory that evolutionary anatomic changes to facilitate speech correlate with OSA severity. The cumulative changes in each cephalometric category trended in the directions hypothesized and support the Great Leap theory of OSA evolution.

  14. Error handling for the CDF Silicon Vertex Tracker

    CERN Document Server

    Belforte, S; Dell'Orso, Mauro; Donati, S; Galeotti, S; Giannetti, P; Morsani, F; Punzi, G; Ristori, L; Spinella, F; Zanetti, A M

    2000-01-01

    The SVT online tracker for the CDF upgrade reconstructs two- dimensional tracks using information from the Silicon Vertex detector (SVXII) and the Central Outer Tracker (COT). The SVT has an event rate of 100 kHz and a latency time of 10 mu s. The system is composed of 104 VME 9U digital boards (of 8 different types) and it is implemented as a data driven architecture. Each board runs on its own 30 MHz clock. Since the data output from the SVT (few Mbytes/sec) are a small fraction of the input data (200 Mbytes/sec), it is extremely difficult to track possible internal errors by using only the output stream. For this reason several diagnostic tools have been implemented: local error registers, error bits propagated through the data streams and the Spy Buffer system. Data flowing through each input and output stream of every board are continuously copied to memory banks named Spy Buffers which act as built in logic state analyzers hooked continuously to internal data streams. The contents of all buffers can be ...

  15. Is identity per se irrelevant? A contrarian view of self-verification effects.

    Science.gov (United States)

    Gregg, Aiden P

    2009-01-01

    Self-verification theory (SVT) posits that people who hold negative self-views, such as depressive patients, ironically strive to verify that these self-views are correct, by actively seeking out critical feedback or interaction partners who evaluate them unfavorably. Such verification strivings are allegedly directed towards maximizing subjective perceptions of prediction and control. Nonetheless, verification strivings are also alleged to stabilize maladaptive self-perceptions, and thereby hindering therapeutic recovery. Despite the widespread acceptance of SVT, I contend that the evidence for it is weak and circumstantial. In particular, I contend that that most or all major findings cited in support of SVT can be more economically explained in terms of raison oblige theory (ROT). ROT posits that people with negative self-views solicit critical feedback, not because they want it, but because they their self-view inclines them regard it as probative, a necessary condition for considering it worth obtaining. Relevant findings are reviewed and reinterpreted with an emphasis on depression, and some new empirical data reported. (c) 2008 Wiley-Liss, Inc.

  16. Approach to the HTGR core outlet temperature measurements in the United States

    International Nuclear Information System (INIS)

    Franklin, R.; Rodriguez, C.

    1982-06-01

    The High Temperature Gas-Cooled Reactor (HTGR) constructed at Fort St. Vrain Colorado (330 MWe) used Geminol thermocouples to measure the primary coolant temperature at the core outlet. The primary coolant (helium) is heated by the graphite core to temperatures in the range of 700 deg. to 750 deg. C. The combination of the high temperature, high flow rate and radiation at the core outlet area makes it difficult to obtain accurate temperature measurements. The Geminol thermocouples installed in the Fort St. Vrain reactor have provided accurate data for several years of power operation without any failures. The indicated temperature of the core outlet thermocouples agrees with a ''traversing'' thermocouple measurement to within +-2 deg. C. The Geminol thermocouple wire was provided by the Driver-Harris Company and is similar to the chromel versus alumel thermocouple. Geminol wire is no longer distributed and on future designs, chromel versus alumel wire will be used. The next large HTGR design, which is being performed with funding support from the United States Department of Energy, will incorporate replaceable thermocouples. The thermocouples used in the Fort St. Vrain reactor were permanently installed and large in diameter (6.35 mm) to insure good reliability. The replaceable thermocouples to be used in the next large reactor will be smaller in diameter (3.18 mm). These replaceable thermocouples will be inserted into the core outlet area through long curved guide tubes that are permanently installed. These guide tubes are as long as 18 meters and must be curved to reach the core outlet regions. Tests were conducted to prove that the thermocouples could be inserted and removed through the long curved guide tubes. (author)

  17. Attenuation of hydrogen radicals traveling under flowing gas conditions through tubes of different materials

    International Nuclear Information System (INIS)

    Grubbs, R.K.; George, S.M.

    2006-01-01

    Hydrogen radical concentrations traveling under flowing gas conditions through tubes of different materials were measured using a dual thermocouple probe. The source of the hydrogen radicals was a toroidal radio frequency plasma source operating at 2.0 and 3.3 kW for H 2 pressures of 250 and 500 mTorr, respectively. The dual thermocouple probe was comprised of exposed and covered Pt/Pt13%Rh thermocouples. Hydrogen radicals recombined efficiently on the exposed thermocouple and the energy of formation of H 2 heated the thermocouple. The second thermocouple was covered by glass and was heated primarily by the ambient gas. The dual thermocouple probe was translated and measured temperatures at different distances from the hydrogen radical source. These temperature measurements were conducted at H 2 flow rates of 35 and 75 SCCM (SCCM denotes cubic centimeter per minute at STP) inside cylindrical tubes made of stainless steel, aluminum, quartz, and Pyrex. The hydrogen radical concentrations were obtained from the temperatures of the exposed and covered thermocouples. The hydrogen concentration decreased versus distance from the plasma source. After correcting for the H 2 gas flow using a reference frame transformation, the hydrogen radical concentration profiles yielded the atomic hydrogen recombination coefficient, γ, for the four materials. The methodology of measuring the hydrogen radical concentrations, the analysis of the results under flowing gas conditions, and the determination of the atomic hydrogen recombination coefficients for various materials will help facilitate the use of hydrogen radicals for thin film growth processes

  18. Brazing of sensors for high-temperature steam instrumentation systems

    International Nuclear Information System (INIS)

    Moorhead, A.J.; Morgan, C.S.; Woodhouse, J.J.; Reed, R.W.

    1981-01-01

    Procedures are developed for brazing a ceramic-to-metal seal and for laser welding of sensor subassemblies into tube walls, induction brazing thermocouples through a tube wall, and furnace brazing triaxial cables, thermocouples, and a vent tube to a guide tube

  19. Device for the measurement and recording of the vertical temperature gradient close to the ground

    International Nuclear Information System (INIS)

    Chassany, J. Ph.; Cottignies, S.

    1963-01-01

    The temperature measurement device described in this note is made of 2 series of 15 copper-constantan thermocouples each, disposed along a mast at 5 m and 20 m from the ground, respectively. Thermocouples are protected against direct sunlight and connected to a recorder

  20. Fabrication of internally instrumented reactor fuel rods

    International Nuclear Information System (INIS)

    Schmutz, J.D.; Meservey, R.H.

    1975-01-01

    Procedures are outlined for fabricating internally instrumented reactor fuel rods while maintaining the original quality assurance level of the rods. Instrumented fuel rods described contain fuel centerline thermocouples, ultrasonic thermometers, and pressure tubes for internal rod gas pressure measurements. Descriptions of the thermocouples and ultrasonic thermometers are also contained

  1. Temperature transient response measurement in flowing water

    International Nuclear Information System (INIS)

    Rainbird, J.C.

    1980-01-01

    A specially developed procedure is described for determining the thermal transient response of thermocouples and other temperature transducers when totally immersed in flowing water. The high velocity heat transfer conditions associated with this facility enable thermocouple response times to be predicted in other fluids. These predictions can be confirmed by electrical analogue experiments. (author)

  2. 10 CFR Appendix O to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Vented Home Heating Equipment

    Science.gov (United States)

    2010-01-01

    ... ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B... an integral draft diverter, install nine thermocouples, wired in parallel, in a horizontal plane in... thermocouples along imaginary lines intersecting at right angles in this horizontal plane at points one third...

  3. Thermal-dissipation sap flow sensors may not yield consistent sap-flux estimates over multiple years

    Science.gov (United States)

    Georgianne W. Moore; Barbara J. Bond; Julia A. Jones; Frederick C. Meinzer

    2010-01-01

    Sap flow techniques, such as thermal dissipation, involve an empirically derived relationship between sap flux and the temperature differential between a heated thermocouple and a nearby reference thermocouple inserted into the sapwood. This relationship has been widely tested but mostly with newly installed sensors. Increasingly, sensors are used for extended periods...

  4. A rigid fast-response thermometer for atmospheric research

    NARCIS (Netherlands)

    van Asselt, C.J.; Jacobs, A.F.G.; van Boxel, J.; Jansen, A.E.

    1991-01-01

    A fast-response temperature sensor for measuring atmospheric temperature was constructed and is described. The sensor was based on the thermocouple principle, connected to a thermocouple conditioner (AD595): the cold junction was compensated via an electrical reference and the signal amplified. This

  5. Experimental validation of error in temperature measurements in thin walled ductile iron castings

    DEFF Research Database (Denmark)

    Pedersen, Karl Martin; Tiedje, Niels Skat

    2007-01-01

    An experimental analysis has been performed to validate the measurement error of cooling curves measured in thin walled ductile cast iron. Specially designed thermocouples with Ø0.2 mm thermocouple wire in Ø1.6 mm ceramic tube was used for the experiments. Temperatures were measured in plates...

  6. Electronic temperature control and measurements reactor fuel rig circuits

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1980-01-01

    The electronic circuits of two digital temperature meters developed for the thermocouple of Ni-NiCr type are described. The output thermocouple signal as converted by means of voltage-to-freguency converter. The frequency is measured by a digital scaler controled by quartz generator signals. One of the described meter is coupled with digital temperature controler which drives the power stage of the reactor rig heater. The internal rig temperature is measured by the thermocouple providing the input signal to the mentioned voltage-to-frequency converter, that means the circuits work in the negative feedback loop. The converter frequency-to-voltage ratio is automatically adjusted to match to thermocouple sensitivity changes in the course of the temperature variations. The accuracy of measuring system is of order of +- 1degC for thermocouple temperature changes from 523 K up to 973 K (50degC up to 700degC).

  7. The electronic temperature control and measurements reactor fuel rig circuits

    International Nuclear Information System (INIS)

    Glowacki, S.W.

    1980-01-01

    The electronic circuits of two digital temperature meters developed for the thermocouple of Ni-NiCr type are described. The output thermocouple signal as converted by means of voltage-to-freguency converter. The frequency is measured by a digital scaler controled by quartz generator signals. One of the described meter is coupled with digital temperature controler which drives the power stage of the reactor rig heater. The internal rig temperature is measured by the thermocouple providing the input signal to the mentioned voltage-to-frequency converter, that means the circuits work in the negative feedback loop. The converter frequency-to-voltage ratio is automatically adjusted to match to thermocouple sensitivity changes in the course of the temperature variations. The accuracy of measuring system is of order of +- 1degC for thermocouple temperature changes from 523 K up to 973 K (50degC up to 700degC). (author)

  8. Taquiarritmias supraventriculares no feto. Experiência de uma unidade de referência em cardiologia fetal Fetal supraventricular tachyarrhythmias. Experience of a fetal cardiology reference center

    Directory of Open Access Journals (Sweden)

    Paulo Zielinsky

    1998-05-01

    referred for fetal cardiac evaluation. RESULTS: There were 17 fetuses with the diagnosis of supraventricular tachycardia (SVT and 8 patients with atrial flutter (AF. Gestational age ranged from 26 to 40 weeks. Twelve patients were hydropic at presentation (6 with SVT and 6 AF. Four fetuses with SVT showed structural abnormalities (two with Ebsten's anomaly and two with VSD. All patients were admitted to the Fetal Cardiology Unit for monitoring and treatment. Among 17 fetuses with SVT, twelve showed good response to digoxin administration, but this drug was not useful in any of the patients with flutter. In two patients with SVT and in six with AF, the pregnancy was interrupted to perform post-natal cardioversion. The mortality rate was 3/17 in the SVT group (including 2 patients with ebstein's anomaly and 0/8 in the flutter group CONCLUSION: Fetal supraventricular tachyarrithmias are rare in the general population. Nevertheless, the fetus may present with severe heart failure and death. Considering the satisfactory therapeutic response, accurate diagnosis and early treatment of these conditions are extremely important.

  9. LOFT fuel rod surface temperature measurement testing

    International Nuclear Information System (INIS)

    Eaton, A.M.; Tolman, E.L.; Solbrig, C.W.

    1978-01-01

    Testing of the LOFT fuel rod cladding surface thermocouples has been performed to evaluate how accurately the LOFT thermocouples measure the cladding surface temperature during a loss-of-coolant accident (LOCA) sequence and what effect, if any, the thermocouple would have on core performance. Extensive testing has been done to characterize the thermocouple design. Thermal cycling and corrosion testing of the thermocouple weld design have provided an expected lifetime of 6000 hours when exposed to reactor coolant conditions of 620 K and 15.9 MPa and to sixteen thermal cycles with an initial temperature of 480 K and peak temperatures ranging from 870 to 1200K. Departure from nucleate boiling (DNB) tests have indicated a DNB penalty (5 to 28% lower) during steady state operation and negligible effects during LOCA blowdown caused by the LOFT fuel rod surface thermocouple arrangement. Experience with the thermocouple design in Power Burst Facility (PBF) and LOFT nonnuclear blowdown testing has been quite satisfactory. Tests discussed here were conducted using both stainless steel and zircaloy-clad electrically heated rod in the LOFT Test Support Facility (LTSF) blowdown simulation loop

  10. Laser Cladding of Embedded Sensors for Thermal Barrier Coating Applications

    Directory of Open Access Journals (Sweden)

    Yanli Zhang

    2018-05-01

    Full Text Available The accurate real-time monitoring of surface or internal temperatures of thermal barrier coatings (TBCs in hostile environments presents significant benefits to the efficient and safe operation of gas turbines. A new method for fabricating high-temperature K-type thermocouple sensors on gas turbine engines using coaxial laser cladding technology has been developed. The deposition of the thermocouple sensors was optimized to provide minimal intrusive features to the TBC, which is beneficial for the operational reliability of the protective coatings. Notably, this avoids a melt pool on the TBC surface. Sensors were deposited onto standard yttria-stabilized zirconia (7–8 wt % YSZ coated substrates; subsequently, they were embedded with second YSZ layers by the Atmospheric Plasma Spray (APS process. Morphology of cladded thermocouples before and after embedding was optimized in terms of topography and internal homogeneity, respectively. The dimensions of the cladded thermocouple were in the order of 200 microns in thickness and width. The thermal and electrical response of the cladded thermocouple was tested before and after embedding in temperatures ranging from ambient to approximately 450 °C in a furnace. Seebeck coefficients of bared and embedded thermocouples were also calculated correspondingly, and the results were compared to that of a commercial standard K-type thermocouple, which demonstrates that laser cladding is a prospective technology for manufacturing microsensors on the surface of or even embedded into functional coatings.

  11. Urine specimen validity test for drug abuse testing in workplace and court settings.

    Science.gov (United States)

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  12. The CDF silicon vertex trigger for B-mesons physics study

    International Nuclear Information System (INIS)

    Belforte, S.; Donati, S.; Ristori, L.; Spinella, F.; Budagov, Yu.; Chlachidze, G.; Glagolev, V.; Semenov, A.; Sisakyan, A.; Punzi, G.

    2001-01-01

    The CDF scientific program includes particularly the study of some key topics of the Standard Model: 1) constraint of the CKM matrix: CP violation in B sector (B 0 → π + π - ) and B s mixing (B s 0 → D s - π + , B s 0 → D s - π + π - π + ); 2) t-quark physics (t → Wb); and processes beyond the Standard Model - e.g., Higgs searching (MSSM) in the H → b bar b mode. All the above processes have the common feature - the presence of b-quarks (B-mesons). B hadrons of sufficiently high transverse momentum are characterized by a large mean value of distribution of the impact parameter with respect to the beam axis. That means events containing this kind of particles can be recognized and separated from non-long-lived background simply by cutting on the track's impact parameter. The upgraded CDF is equipped by the so-called Silicon Vertex Tracker (SVT), a unique electronic device for real time track reconstruction using the data from two CDF track detectors: the silicon strip vertex detector and drift chamber. The SVT is a level-2 trigger which within 10 μs reconstructs the tracks and obtains the transverse momentum (p t ), azimuthal angle (φ) and impact parameter (d) with 30 μm precision. The simulation studies show the background reduction by factor 1000 for B 0 π + π - by demand d > 100 μm for at least two tracks. This trigger is the first one of this sort ever used for hadron collider experiments: it enables to trigger on the secondary vertex, which opens the unique new opportunities in the heavy quark physics study. The basic logic, architecture and perspectives of SVT application are briefly described

  13. Examination of the Mild Brain Injury Atypical Symptom Scale and the Validity-10 Scale to detect symptom exaggeration in US military service members.

    Science.gov (United States)

    Lange, Rael T; Brickell, Tracey A; French, Louis M

    2015-01-01

    The purpose of this study was to examine the clinical utility of two validity scales designed for use with the Neurobehavioral Symptom Inventory (NSI) and the PTSD Checklist-Civilian Version (PCL-C); the Mild Brain Injury Atypical Symptoms Scale (mBIAS) and Validity-10 scale. Participants were 63 U.S. military service members (age: M = 31.9 years, SD = 12.5; 90.5% male) who sustained a mild traumatic brain injury (MTBI) and were prospectively enrolled from Walter Reed National Military Medical Center. Participants were divided into two groups based on the validity scales of the Minnesota Multiphasic Personality Inventory-2 Restructured Form (MMPI-2-RF): (a) symptom validity test (SVT)-Fail (n = 24) and (b) SVT-Pass (n = 39). Participants were evaluated on average 19.4 months postinjury (SD = 27.6). Participants in the SVT-Fail group had significantly higher scores (p scales (d = 0.69 to d = 2.47). Sensitivity, specificity, and predictive power values were calculated across the range of mBIAS and Validity-10 scores to determine the optimal cutoff to detect symptom exaggeration. For the mBIAS, a cutoff score of ≥8 was considered optimal, which resulted in low sensitivity (.17), high specificity (1.0), high positive predictive power (1.0), and moderate negative predictive power (.69). For the Validity-10 scale, a cutoff score of ≥13 was considered optimal, which resulted in moderate-high sensitivity (.63), high specificity (.97), and high positive (.93) and negative predictive power (.83). These findings provide strong support for the use of the Validity-10 as a tool to screen for symptom exaggeration when administering the NSI and PCL-C. The mBIAS, however, was not a reliable tool for this purpose and failed to identify the vast majority of people who exaggerated symptoms.

  14. Test Characteristics of Neck Fullness and Witnessed Neck Pulsations in the Diagnosis of Typical AV Nodal Reentrant Tachycardia

    Science.gov (United States)

    Sakhuja, Rahul; Smith, Lisa M; Tseng, Zian H; Badhwar, Nitish; Lee, Byron K; Lee, Randall J; Scheinman, Melvin M; Olgin, Jeffrey E; Marcus, Gregory M

    2011-01-01

    Summary Background Claims in the medical literature suggest that neck fullness and witnessed neck pulsations are useful in the diagnosis of typical AV nodal reentrant tachycardia (AVNRT). Hypothesis Neck fullness and witnessed neck pulsations have a high positive predictive value in the diagnosis of typical AVNRT. Methods We performed a cross sectional study of consecutive patients with palpitations presenting to a single electrophysiology (EP) laboratory over a 1 year period. Each patient underwent a standard questionnaire regarding neck fullness and/or witnessed neck pulsations during their palpitations. The reference standard for diagnosis was determined by electrocardiogram and invasive EP studies. Results Comparing typical AVNRT to atrial fibrillation (AF) or atrial flutter (AFL) patients, the proportions with neck fullness and witnessed neck pulsations did not significantly differ: in the best case scenario (using the upper end of the 95% confidence interval [CI]), none of the positive or negative predictive values exceeded 79%. After restricting the population to those with supraventricular tachycardia other than AF or AFL (SVT), neck fullness again exhibited poor test characteristics; however, witnessed neck pulsations exhibited a specificity of 97% (95% CI 90–100%) and a positive predictive value of 83% (95% CI 52–98%). After adjustment for potential confounders, SVT patients with witnessed neck pulsations had a 7 fold greater odds of having typical AVNRT, p=0.029. Conclusions Although neither neck fullness nor witnessed neck pulsations are useful in distinguishing typical AVNRT from AF or AFL, witnessed neck pulsations are specific for the presence of typical AVNRT among those with SVT. PMID:19479968

  15. Temperature estimates from the zircaloy oxidation kinetics in the α plus β phase region

    International Nuclear Information System (INIS)

    Olsen, C.S.

    1981-01-01

    Oxidation rates of zircaloy in steam were measured at temperatures between 961 and 1264 K and for duration times between 25 and 1900 seconds in order to calculate, in conjunction with measurements from postirradiation metallographic examination, the prior peak temperatures of zircaloy fuel rod cladding. These temperature estimates will be used in light water reactor research programs to assess (a) the accuracy of temperature measurements of fuel rod cladding peak temperatures from thermocouples attached to the surface during loss-of-coolant experiments (LOCEs), (b) the perturbation of the fuel rod cladding LOCE temperature history caused by the presence of thermocouples, and (c) the measurements of cladding azimuthal temperature gradients near thermocouple locations

  16. Advances in measuring techniques for turbine cooling test rigs - Status report

    Science.gov (United States)

    Pollack, F. G.

    1974-01-01

    Instrumentation development pertaining to turbine cooling research has resulted in the design and testing of several new systems. Pressure measurements on rotating components are being made with a rotating system incorporating ten miniature transducers and a slip-ring assembly. The system has been tested successfully up to speeds of 9000 rpm. An advanced system development combining pressure transducer and thermocouple signals is also underway. Thermocouple measurements on rotating components are transferred off the shaft by a 72-channel rotating data system. Thermocouple data channels are electronically processed on board and then removed from the shaft in the form of a digital serial train by one winding of a rotary transformer.

  17. Cutting temperature measurement and material machinability

    Directory of Open Access Journals (Sweden)

    Nedić Bogdan P.

    2014-01-01

    Full Text Available Cutting temperature is very important parameter of cutting process. Around 90% of heat generated during cutting process is then away by sawdust, and the rest is transferred to the tool and workpiece. In this research cutting temperature was measured with artificial thermocouples and question of investigation of metal machinability from aspect of cutting temperature was analyzed. For investigation of material machinability during turning artificial thermocouple was placed just below the cutting top of insert, and for drilling thermocouples were placed through screw holes on the face surface. In this way was obtained simple, reliable, economic and accurate method for investigation of cutting machinability.

  18. Temperature measurements of the aluminium claddings of fuel elements in nuclear reactor

    International Nuclear Information System (INIS)

    Chen Daolong

    1986-01-01

    A method for embedding the sheathed thermocouples in the aluminium claddings of some fuel elements of experimental reactors by ultrasonic welding technique is described. The measurement results of the cladding temperature of fuel elements in reactors are given. By means of this method, the joint between the sheathed thermocouples and the cladding of fuel elements can be made very tight, there are no bulges on the cladding surfaces, and the sheathed thermocouples are embedded strongly and reliably. Therefore an essential means is provided for acquiring the stable and dynamic state data of the cladding temperature of in-core fuel elements

  19. A Revolutionary War: Korea and the Transformation of the Postwar World

    Science.gov (United States)

    1992-10-01

    THE AMERICAN ROE FRONT ...................................... 3 XIX MEDIA COVERAGE OF THE WAR .... . . ............. ..................I ...7 XX. FILM...Oen.. Htst . Branch, 1958 (UC 34 AI5 sVt 2 nO 2) lsp. DeU isiod U .n La .N York McBride. 1994 (DS 918 .173) 39 Rood. John C. 1 aly" XAJ L Wlhi"l± ~SfDA...Dec 1950) 080- e81 77 MEDIA EnS ERAGE OF THE WAR Books. Government Fuhl.catios. and Reports Diels%1,o Dwightl C Th.illtary and the Meia Historical

  20. Detection of suboptimal effort with symbol span: development of a new embedded index.

    Science.gov (United States)

    Young, J Christopher; Caron, Joshua E; Baughman, Brandon C; Sawyer, R John

    2012-03-01

    Developing embedded indicators of suboptimal effort on objective neurocognitive testing is essential for detecting increasingly sophisticated forms of symptom feigning. The current study explored whether Symbol Span, a novel Wechsler Memory Scale-fourth edition measure of supraspan visual attention, could be used to discriminate adequate effort from suboptimal effort. Archival data were collected from 136 veterans classified into Poor Effort (n = 42) and Good Effort (n = 94) groups based on symptom validity test (SVT) performance. The Poor Effort group had significantly lower raw scores (p Span test. A raw score cutoff of Span can effectively differentiate veterans with multiple failures on established free-standing and embedded SVTs.

  1. Evaluation of Effect of Postoperative Wound Drainage Reinfusion Using the Solcotrans Orthopaedic Drainage/Reinfusion System in Reducing the Need for Whole Blood Transfusion (HSC)

    Science.gov (United States)

    1991-03-01

    REINFUSION SYSTEM IN REDUCING THE NEED FOR WHOLE BLOOD TRANSFUSION (HSC) PRINCIPAL INVESTIGATOR: Allan L. Bucknell, M.D. AUTHORS: Michael B. Simpson, M.D...einfysion SVt8T in Reducing the Need for whole Blood rans uson , 61102A Allan L. Bucknell, M.D.; Michael B. Simpson, M.D. 3MI61102BS12.ZZ Kevin P...for transfusion. J Bone Joint Suig. 1987; 6,QA:319). 3. Tlhomson JD), C al laghan JJ, Savory C’G, Stanton RP, Pierce RN. P’rior deposition of

  2. The STAR cluster-finder ASIC

    Energy Technology Data Exchange (ETDEWEB)

    Botlo, M.; LeVine, M.J.; Scheetz, R.A.; Schulz, M.W. [Brookhaven National Lab., Upton, NY (United States); Short, P.; Woods, J. [InnovASIC, Inc., Albuquerque, NM (United States); Crosetto, D. [Rice Univ., Houston, TX (United States). Bonner Nuclear Lab.

    1997-12-01

    STAR is a large TPC-based experiment at RHIC, the relativistic heavy ion collider at Brookhaven National Laboratory. The STAR experiment reads out a TPC and an SVT (silicon vertex tracker), both of which require in-line pedestal subtraction, compression of ADC values from 10-bit to 8-bit, and location of time sequences representing responses to charged-particle tracks. The STAR cluster finder ASIC responds to all of these needs. Pedestal subtraction and compression are performed using lookup tables in attached RAM. The authors describe its design and implementation, as well as testing methodology and results of tests performed on foundry prototypes.

  3. The SuperB Silicon Vertex Tracker and 3D vertical integration

    CERN Document Server

    Re, Valerio

    2011-01-01

    The construction of the SuperB high luminosity collider was approved and funded by the Italian government in 2011. The performance specifications set by the target luminosity of this machine (> 10^36 cm^-2 s^-1) ask for the development of a Silicon Vertex Tracker with high resolution, high tolerance to radiation and excellent capability of handling high data rates. This paper reviews the R&D activity that is being carried out for the SuperB SVT. Special emphasis is given to the option of exploiting 3D vertical integration to build advanced pixel sensors and readout electronics that are able to comply with SuperB vertexing requirements.

  4. Overwintering temperatures affect freezing temperatures of turions of aquatic plants

    Czech Academy of Sciences Publication Activity Database

    Adamec, Lubomír; Kučerová, Andrea

    2013-01-01

    Roč. 208, 8-9 (2013), 497-501 ISSN 0367-2530 Institutional support: RVO:67985939 Keywords : mini thermocouples * frost resistance * hardening Subject RIV: EF - Botanics Impact factor: 1.462, year: 2013

  5. Measurement of temperature fields in specimens of quartz ceramic during surface ablation

    Science.gov (United States)

    Frolov, G. A.; Pasichnyi, V. V.; Suzdal'Tsev, E. I.; Tsyganenko, V. S.

    1989-08-01

    The authors propose a method of mounting thermocouples and have obtained temperature fields within specimens of pure and doped quartz ceramic. The linearity of the dependenceΔ * = fleft( {sqrt tau } right) for deep isotherms has been proved experimentally.

  6. Effect of surfactants in synthesis of CsH2PO4 as protonic conductive ...

    Indian Academy of Sciences (India)

    Administrator

    Chemical Engineering Process, University Kebangsaan Malaysia, 43600 Bangi, .... 6100, a furnace with standard thermocouple °C under ..... The authors appreciate the financial support of the IRPA- ... Laboratory Report LAUR 86-748, USA.

  7. DESEMPENHO DE DIFERENTES BITOLAS DE TERMOPAR EM UM PSICRÔMETRO ASPIRADO DE BAIXO CUSTO

    Directory of Open Access Journals (Sweden)

    CLÁUDIO RICARDO DA SILVA

    2011-01-01

    Full Text Available The objective of this work was to evaluate an aspirated psychrometer constructed under different thermocouple gauges. Were used three thermocouple copper-constantan gauge: 24 AWG (0.511 mm of diameter, 32 AWG (0.202 mm of diameter and 40 AWG (0.080 mm of diameter. The thermocouples were placed into a single psychrometer and each one positioned side by side at a distance of approximately 30 mm each other. Hourly air temperature and humidity values obtained from each gauge were compared with the values obtained with a thermistor and capacitive hygrometer. The results showed that the thermocouple gauges used (24, 32 and 40 AWG had high correlation and accuracy with values determined by the hygrometer (r2 > 0.97, RMSE P 3.91%.

  8. Temperature control of the graphite stack of the reactor RBMK-1500

    International Nuclear Information System (INIS)

    Lesnoj, S.

    1998-01-01

    The paper includes general information about RBMK-1500 reactor, construction features and main technical data; graphite moderator stack, temperature channel, thermocouple TXA-1379, its basic technical and metrologic parameters as well as its advantages and disadvantages

  9. Irradiation of reactor materials within projects VISA-2 and 3, 3. Construction and testing of the capsules and containers VISA - Phase I (Part I and II), Vol. I; Ozracivanje reaktorskih materijala po projektima VISA-2 i 3, 3. Osvajanje postupka izrade i ispitivanja kapsula i kenera VISA - I faza (I i II deo), I deo, Album I

    Energy Technology Data Exchange (ETDEWEB)

    Pavicevic, M; Putre, R [Institute of Nuclear Sciences Boris Kidric, Odeljenje za reaktorsku eksperimentalnu tehniku, Vinca, Beograd (Serbia and Montenegro)

    1964-02-15

    The task contains studies of materials for constructing capsules, leak tight capsules and containers made of aluminium and stainless steels. Special attention is devoted to study of welding the closures and claddings of the capsules as well as thermocouples.

  10. Measurement of the vertical temperature gradient at the Saclay Nuclear Research Centre

    International Nuclear Information System (INIS)

    Santelli, F.; Le Quino, R.

    1962-01-01

    A 109 m mast has been erected at the Saclay Nuclear Research Centre for the precise measurement of thermal gradients and gaseous effluents. This note describes the temperature measurement devices (thermocouple and thermo-resistor) and the first results obtained

  11. Linear heating system for measurement of thermoluminescence ...

    Indian Academy of Sciences (India)

    Unknown

    through the terminal keyboard enters experimental vari- ables and ... chromel alumel thermocouple is spot welded on the bot- tom of the ... (BD136), which is implemented by designing the firing ... The use of a microcontroller, the process of.

  12. PM From the Combustion of heavy fuel oils

    KAUST Repository

    Elbaz, Ayman M.; khateeb, A.A.; Roberts, William L.

    2018-01-01

    to the thermal history, which was controlled by the heated co-flow velocity. In the suspended droplet experiments, by suspending the droplet on a thermocouple, the temperature inside the droplet was measured while simultaneously imaging the various burning phases

  13. Temperature measurements at the LMFBR core outlet

    International Nuclear Information System (INIS)

    Argous, J.P.; Berger, R.; Casejuane, R.; Fournier, C.; Girard, J.P.

    1980-04-01

    Over the last few years the temperature sensors used to measure the subassembly outlet temperature in French designed LMFBRs have been modified, basically in an effort to reduce the dispersion of the chromel-alumel thermocouple time constant, and to extend the frequency spectrum of the measurement signals by adding a steel electrode to from a stainless steel-sodium thermocouple. The result of this evolution is the temperature probe immersed in sodium which will be used in the SUPER PHENIX reactor. This paper describes the tests already completed or in progress on this probe. It also presents measurement data on the two basic probe parameters: the thermoelectric power of the stainless steel-sodium thermocouple and the time constant of the chromel-alumel thermocouple

  14. Development of an Inverse Technique to Estimate the Ultrasound Field During Chest Wall and Breast Hyperthermia

    National Research Council Canada - National Science Library

    Thomas, Charles

    1997-01-01

    ... of a patient registration and tissue geometry acquisition system based on the same B-scan hardware, and investigation of the accuracy of thermocouple measurements to determine ultrasound power incident at a point in tissue...

  15. Investigation of the effects of quarl and initial conditions on swirling non-premixed methane flames: Flow field, temperature, and species distributions

    KAUST Repository

    Elbaz, Ayman M.; Roberts, William L.

    2015-01-01

    thermocouple and sampling probe, respectively. This work provides experimental verification by complementary techniques. The results showed that although the main flame structures were governed by the swirl motion imparted to the air stream, the quarl geometry

  16. Measurement of neutral beam power and beam profile distribution on DNB

    International Nuclear Information System (INIS)

    Liu Zhimin; Liu Sheng; Song Shihua; Han Xiaopu; Li Jun; Hu Chundong; Hu Liqun; Xie Jun

    2005-01-01

    The injection power of a diagnostic neutral beam (DNB) can be obtained with the thermocouple probe measurement system on the Hefei superconducting Tokamak-7 (HT-7). With the 49 kv, 6 A, 100 ms pulse charge of an acceleration electrode, a thermocouple probe measurement system with 13 thermocouples crossly distributed on a coppery heat target was used to measure the temperature rise of the target, and the maximum measured temperature rise was 14 degree C. And the neutral beam power of 160 kW and beam profile distribution was obtained by calculation. The total neutral beam power of 130 kW was also obtained by integral calculation with the temperature rise on the heat section board. The difference between the two means was analyzed. The experiment results shows that the method of heat section board with thermocouple probe is one of the effective ways to measure the beam power and beam profile distribution. (authors)

  17. Mechanical characterization of microwave sintered zinc oxide

    Indian Academy of Sciences (India)

    Unknown

    ultrasonic time of flight measurement using a 15 MHz transducer. .... Figure 1. Microwave heating system (a. thermocouple, b. porous refractory box, c. sample, d. fibrous insulation material, e. power control, f. timer and g. display panel). a b c d.

  18. A prototype of on-line digital flow rate meter based on cross-correlation principle

    International Nuclear Information System (INIS)

    Sun Xiaodong; Dai Zhenxi; Xu Jijun

    1997-01-01

    An on-line, digital prototype of flow rate measurement system based on cross-correlation principle is developed. Laboratory measurements using the prototype show that sufficiently large temperature fluctuations exist naturally and that measurements are possible. Temperature fluctuations are detected by two identical thermocouples spaced along the flow direction and are pre-processed by a thermocouple signal amplifier. The pre-processed temperature fluctuations are analyzed by a cross-correlator which measures the transit time of temperature fluctuations between two thermocouples directly. Thus, the so-called correlation velocity can be determined by a chip microprocessor 8031. Experimental results with single-phase under steady conditions also show that the distance between two thermocouples and the Reynolds number of fluid are the most important parameters to the measurement

  19. Ion thermometers in reactor technology

    International Nuclear Information System (INIS)

    Yakesh, D.; Kott, J.; Strnad, M.

    1980-01-01

    The width of the temperature discontinuity and the thermometric stability of the sensors are constant up to very high flux values. The immediate influence of irradiation is reduced to a decrease in the hysteresis of the conduction curve at the phase transition. When the readings of the ion thermometers are compared with the reading of Chromel-Alumel thermocouples, it is observed that the temperature difference amounts to approximately 7/degree/C in the case of thermocouples placed at the sensor socket; the temperature difference decreases to 2/degree/C in the case of the thermocouple junction situated between the electrodes. The good results obtained in the testing of the ion thermometers in nuclear reactors lead to the conclusion that these temperature sensors are promising for checking thermocouples in the core of nuclear power stations

  20. 40 CFR 63.751 - Monitoring requirements.

    Science.gov (United States)

    2010-07-01

    ... challenge the monitors with compounds representative of the gaseous emission stream being controlled. (B) If... substantial heat exchange occurs. (10) Where a catalytic incinerator is used, thermocouples, each equipped...

  1. Metabolic rate and body temperature of an African sun bird ...

    African Journals Online (AJOL)

    1997-02-19

    Feb 19, 1997 ... has a wide distribution in southern Africa. ... sample the voltage output of the oxygen analyser every 2 min ... Bailey Bat thermocouple thermometer, and the system was .... A similar 50% drop in metabolic rate in finches at.

  2. Experiments and simulations of NOx formation in the combustion of hydroxylated fuels

    KAUST Repository

    Bohon, Myles; Rachidi, Mariam El; Sarathy, Mani; Roberts, William L.

    2015-01-01

    and flame temperature profiles utilizing a rake of thermocouples were obtained in globally lean, swirling, liquid atomized spray flames inside a refractory-lined combustion chamber as a function of the atomizing air flow rate and swirl number

  3. EBR-II in-vessel natural circulation experiments on hot and cold pool stratification

    International Nuclear Information System (INIS)

    Ragland, W.A.; Feldman, E.E.

    1990-01-01

    The Experimental Breeder Reactor II is located in a cylindrical pool of liquid sodium which is part of the cold-leg of the primary flow circuit. A vertical string of 32 thermocouples spans the 8 m tank height, at each of two diametrically opposed locations in the primary tank. Local temperatures were measured with these 64 thermocouples during dynamic tests. The instantaneous spacial temperature distribution obtained from a string of thermocouples can be viewed on a personal computer. The animation which results from displaying successive spacial distributions provide a very effective way to quickly obtain physical insights. The design of the two strings of thermocouples, the software used to create the animation, measured data from three different types of tests--two unprotected reactor transients, and one with the reactor at decay power levels and the reactor cover lifted, are discussed. 5 refs., 3 figs

  4. 植込み型センサを用いたハイパーサーミア用多チャネル温度測定装置の開発

    OpenAIRE

    真柄, 睦; 斉藤, 義明; 木竜, 徹; 牧野, 秀夫; Magara, Makoto; Saitoh, Yoshiaki; Kiryu, Tohru; Makino, Hideo

    1987-01-01

    Up to date, thermocouple sensors have been applied in temperature monitoring during hyperthermia. However, using thermocouple sensors, infection and metastasis may be caused by inserting and removing the sensing wires. We have therefore developed a completely implantable temperature sensor which does not require a battery. The sensor consists of a coil which transmits signals to the receiver coil outside the body and a quartz resonator. And its resonance frequency varies with ambient temperat...

  5. Gas temperature measurements in short duration turbomachinery test facilities

    Science.gov (United States)

    Cattafesta, L. N.; Epstein, A. H.

    1988-07-01

    Thermocouple rakes for use in short-duration turbomachinery test facilities have been developed using very fine thermocouples. Geometry variations were parametrically tested and showed that bare quartz junction supports (76 microns in diameter) yielded superior performance, and were rugged enough to survive considerable impact damage. Using very low cost signal conditioning electronics, temperature accuracies of 0.3 percent were realized yielding turbine efficiency measurements at the 1-percent level. Ongoing work to improve this accuracy is described.

  6. Effect of different light curing units on Knoop hardness and temperature of resin composite

    OpenAIRE

    Guiraldo Ricardo; Consani Simonides; Xediek Consani Rafael; Mendes Wilson; Lympius Thais; Coelho Sinhoreti Mario

    2009-01-01

    Aim: To evaluate the influence of quartz tungsten halogen and plasma arc curing (PAC) lights on Knoop hardness and change in polymerization temperature of resin composite. Materials and Methods: Filtek Z250 and Esthet X composites were used in the shade A3. The temperature increase was registered with Type-k thermocouple connected to a digital thermometer (Iopetherm 46). A self-cured polymerized acrylic resin base was built in order to guide the thermocouple and to support the dentin disk ...

  7. Thermal conductivity of 238PuO2 powder, intermediates, and dense fuel forms

    International Nuclear Information System (INIS)

    Bickford, D.F.; Crain, B. Jr.

    1975-10-01

    The thermal conductivities of porous 238 PuO 2 powder (calcined oxalate), milled powder, and high-density granules were calculated from direct measurements of steady-state temperature profiles resulting from self-heating. Thermal conductivities varied with density, temperature, and gas content of the pores. Errors caused by thermocouple heat conduction were less than 5 percent when the dimensions of the thermal conductivity cell and the thermocouple were properly selected

  8. Temperature measuring device

    International Nuclear Information System (INIS)

    Brixy, H.

    1977-01-01

    The temperature measuring device is equipped with an electric resistor installed within a metal shroud tube so as to be insulated from it, the noise voltage of which resistor is fed to a measuring unit. The measuring junctions of one or two thermocouples are connected with the electric resistor and the legs of one or both thermocouples can be connected to the measuring unit by means of a switch. (orig.) [de

  9. Confinement of Neutral Beam Ions in the National Spherical Torus Experiment

    International Nuclear Information System (INIS)

    Darrow, D.S.; Medley, S.S.; Roquemore, A.L.; Rosenberg, A.

    2001-01-01

    The loss of neutral-beam ions to the wall has been measured in the National Spherical Torus Experiment (NSTX) by means of thermocouples, an infrared (IR) camera, and a Faraday cup probe. The losses tend to exhibit the expected dependences on plasma current, tangency radius of the injector, and plasma outer gap. However, the thermocouples and the Faraday cups indicate substantially different levels of loss and this difference has yet to be understood

  10. Radiation hazard detector

    International Nuclear Information System (INIS)

    Aslan, E.E.

    1986-01-01

    This patent describes an electric field sensitive probe comprising a set of sensing elements including a diode sensing element and a thermocouple sensing element. The diode sensing element is connected to a dipole and circuitry to exhibit a predetermined sensitivity to the field over a lower range of frequency, and the thermocouple sensing element exhibiting predetermined sensitivity to the field over a higher range of frequency. The lower and higher ranges are substantially adjacent to one another

  11. Instrument response during overpower transients at TREAT

    International Nuclear Information System (INIS)

    Meek, C.C.; Bauer, T.H.; Hill, D.J.; Froehle, P.H.; Klickman, A.E.; Tylka, J.P.; Doerner, R.C.; Wright, A.E.

    1982-01-01

    A program to empirically analyze data residuals or noise to determine instrument response that occurs during in-pile transient tests is out-lined. As an example, thermocouple response in the Mark III loop during a severe overpower transient in TREAT is studied both in frequency space and in real-time. Time intervals studied included both constant power and burst portions of the power transient. Thermocouple time constants were computed. Benefits and limitations of the method are discussed

  12. The Thermal Evaluation of Air-Cooled Electronic Equipment

    Science.gov (United States)

    1952-09-01

    Temperatures 22 5. Primary Thermometric Elements. Thermocouples 23 6. Instruments for Thermocouples 30 7. Checking for Operation within Specified...from the outer container wall to the atmosphere of the room. For the con- struction of the inner container, polished aluminum is desirable so as to... aluminum , is to prevent radiant heat transfer from the component to be tested so that cooling can only occur by free convection. Thus, the most

  13. Effect of Cetane Improver on Autoignition Characteristics of Low Cetane Sasol IPK Using Ignition Quality Tester (IQT)

    Science.gov (United States)

    2013-10-13

    and deliver it into the chamber through an inward opening single-hole pintle-type injector nozzle . The needle is spring-loaded with a screw and a...direction. The first thermocouple measures the charge temperature close by the injector nozzle , the second thermocouple is 7 cm downstream from the... diesel engines. The ignition quality of a fuel is rated by its cetane number (CN) measured in a Cooperative Fuel Research (CFR) engine according to

  14. Uncertainty analysis of thermal quantities measurement in a centrifugal compressor

    Science.gov (United States)

    Hurda, Lukáš; Matas, Richard

    2017-09-01

    Compressor performance characteristics evaluation process based on the measurement of pressure, temperature and other quantities is examined to find uncertainties for directly measured and derived quantities. CFD is used as a tool to quantify the influences of different sources of uncertainty of measurements for single- and multi-thermocouple total temperature probes. The heat conduction through the body of the thermocouple probe and the heat-up of the air in the intake piping are the main phenomena of interest.

  15. Biological Effects of Nonionizing Electromagnetic Radiation. Volume IV. Number 3.

    Science.gov (United States)

    1980-03-01

    29- gauge thermocouples were inserted into the tumor center and in its deepest aspect. Thermocouples 6429 EMPLOYMENT OF MAGNETOTHERAPY IN THE CON...hyperthermia generally ranged from slight to severe erythema. Although good data were difficult to The therapeutic effectiveness of magnetotherapy obtain...subcutaneous tissue can be heated to 41-42 C for received magnetotherapy in addition to the con- periods up to 2 hr after RT without any evidence of I

  16. Microprocessor-controlled Nd:YAG laser for hyperthermia induction in the RIF-1 tumor.

    Science.gov (United States)

    Waldow, S M; Russell, G E; Wallner, P E

    1992-01-01

    Near-infrared radiation from a Nd:YAG laser at 1,064 nm was used interstitially or superficially to induce hyperthermia in RIF-1 tumors in C3H male mice. A single 600-microns quartz fiber with a 0.5-cm cylindrical diffusor or a weakly diverging microlens at its distal end was used to deliver laser energy to tumors in the hind leg (mean volume = 100 mm3). Two thermocouples were inserted into each tumor. One thermocouple controlled a microprocessor-driven hyperthermia program (maximum output of 3.5 Watts) to maintain the desired temperature. Tumors were exposed to various temperature-time combinations (42-45 degrees C/30 min). Our initial results indicated that excellent temperature control to within 0.2 degrees C of the desired temperature at the feedback thermocouple was achievable during both superficial and interstitial heat treatments. Temperatures at the second thermocouple, however, were found to be lower by as much as 2.3 degrees C (using the cylindrical diffusor) or higher by up to 4.6 degrees C (using the microlens) when compared to the feedback thermocouple temperature. Several correlations were seen between total dose, tumor growth delay, percent skin necrosis, and temperature at the second thermocouple after several superficial and interstitial treatments. Statistically significant improvements in tumor growth delay (at 42 and 45 degrees C) and increased percent skin necrosis at all temperatures were observed after superficial versus interstitial treatment.

  17. Temperature Measurements of the Low-Attenuation Radiographic Ice Ball During CT-Guided Renal Cryoablation

    International Nuclear Information System (INIS)

    Permpongkosol, Sompol; Link, Richard E.; Kavoussi, Louis R.; Solomon, Stephen B.

    2008-01-01

    During renal cryoablation a low-attenuation area on CT develops around the cryoprobe. Knowledge of the temperature of the growing low-attenuation area can guide therapy and ensure lethal temperatures. Herein, we report thermocouple results and correlating CT images during the development of the low-attenuation 'radiographic ice ball.' Five patients who underwent percutaneous CT-guided renal cryoablation were identified who had thermocouples inserted and serial intraprocedural CT images that included images with thermocouple measurements of 0 o and sub-0 o C. Thermocouples had been percutaneously placed just beyond the edge of the tumors either to ensure adequate cooling or to ensure safety to adjacent critical structures. Renal cryotherapy under CT guidance produced a growing low-attenuation area corresponding to the radiographic ice ball. When the thermocouple measured 0 o C, CT images showed the thermocouple tip at the edge of the low-attenuation ice ball. At lower temperatures the tip was within the low-attenuation ice ball. We conclude that knowledge of the temperature at the ice ball edge during cryoablation can be used to predict the extent of tissue necrosis and thus provide an estimate of cryotherapy effectiveness during the procedure. Further work is necessary to establish a firm relationship between the thermal conditions and the zone of damage

  18. A 240-channel thick film multi-chip module for readout of silicon drift detectors

    International Nuclear Information System (INIS)

    Lynn, D.; Bellwied, R.; Beuttenmueller, R.; Caines, H.; Chen, W.; DiMassimo, D.; Dyke, H.; Elliott, D.; Grau, M.; Hoffmann, G.W.; Humanic, T.; Jensen, P.; Kleinfelder, S.A.; Kotov, I.; Kraner, H.W.; Kuczewski, P.; Leonhardt, B.; Li, Z.; Liaw, C.J.; LoCurto, G.; Middelkamp, P.; Minor, R.; Mazeh, N.; Nehmeh, S.; O'Conner, P.; Ott, G.; Pandey, S.U.; Pruneau, C.; Pinelli, D.; Radeka, V.; Rescia, S.; Rykov, V.; Schambach, J.; Sedlmeir, J.; Sheen, J.; Soja, B.; Stephani, D.; Sugarbaker, E.; Takahashi, J.; Wilson, K.

    2000-01-01

    We have developed a thick film multi-chip module for readout of silicon drift (or low capacitance ∼200 fF) detectors. Main elements of the module include a custom 16-channel NPN-BJT preamplifier-shaper (PASA) and a custom 16-channel CMOS Switched Capacitor Array (SCA). The primary design criteria of the module were the minimizations of the power (12 mW/channel), noise (ENC=490 e - rms), size (20.5 mmx63 mm), and radiation length (1.4%). We will discuss various aspects of the PASA design, with emphasis on the preamplifier feedback network. The SCA is a modification of an integrated circuit that has been previously described [1]; its design features specific to its application in the SVT (Silicon Vertex Tracker in the STAR experiment at RHIC) will be discussed. The 240-channel multi-chip module is a circuit with five metal layers fabricated in thick film technology on a beryllia substrate and contains 35 custom and commercial integrated circuits. It has been recently integrated with silicon drift detectors in both a prototype system assembly for the SVT and a silicon drift array for the E896 experiment at the Alternating Gradient Synchrotron at the Brookhaven National Laboratory. We will discuss features of the module's design and fabrication, report the test results, and emphasize its performance both on the bench and under experimental conditions

  19. Immediate postoperative digitalization in the prophylaxis of supraventricular arrhythmias following coronary artery bypass.

    Science.gov (United States)

    Csicsko, J F; Schatzlein, M H; King, R D

    1981-03-01

    Regimens of acute preoperative digitalization have been evaluated previously in the prophylaxis of supraventricular tachycardias (SVT) following coronary artery bypass operations, with equivocal results. This study assesses the effectiveness of immediate postoperative digitalization on the incidence of arrhythmias in 407 consecutive patients recovering from myocardial revascularization. In 137 patients treated by our regimen, which begins digitalization within 4 hours postoperatively, the incidence of supraventricular tachyarrhythmias was 2%, while the corresponding figure for 270 untreated patients was 15%. Digitalization reduced the incidence of supraventricular arrhythmias significantly (p less than 0.01), whereas death, ventricular ectopy, and infarction rates were similar in the two groups. The few patients who did have supraventricular arrhythmias while receiving prophylactic digoxin were no more easily treated than patients in the undigitalized group. The timing of administration of digoxin for SVT prophylaxis may be more important than previously recognized. Immediately postoperative digitalization, theoretically preferable to preoperative regimens, is a safe, effective way to reduce the incidence of supraventricular arrhythmias following myocardial revascularization.

  20. Production of bioenergy in anaerobic baffled reactor (ABR) and sludge blanket (UASB) in the treatment os swine waste water; Producao de bioenergia em reatores anaerobios compartimentado (RAC) e de manta de lodo (UASB) no tratamento de efluentes de suinocultura

    Energy Technology Data Exchange (ETDEWEB)

    Moterani, Fabricio; Pereira, Erlon Lopes; Campos, Claudio M.M. [Universidade Federal de Lavras (DEG/UFLA), MG (Brazil). Dept. de Engenharia], email: fabricio_moterani@yahoo.com.br

    2011-07-01

    The biogas is obtained in the processes of degradation of organic matter by the action of bacterial consortium in the environment. The aim of this study was to evaluate the biogas production in anaerobic UASB and ABR in swine wastewater treatment. For this we used the theoretical estimated and actual production of biogas measured by anaerobic gasometers installed in the units. Methane was determined by gas chromatography (GC) and its theoretical output was 66 LCH4 kgSVT d{sup -1} and 11.9 LCH4 kgSVT d{sup -1} and 24.7 m{sup 3} d{sup -1} and 5.4 m{sup 3} d{sup -1} to ABR and UASB, respectively. Regarding the actual production of biogas in the reactor provided by the gas tank, found the values of 1,166.4 m{sup 3}; 0.1 m{sup 3}; 27.4 m{sup 3} and 12,598.5 m{sup 3} of biogas for compartments 1, 2 and 3 and ABR for the UASB reactor, respectively, totaling, production of 13,792.4 m{sup 3} in the units together, with an average of 113 m{sup 3} of biogas per day. But, it concludes with this research that the use of effluent from produce energy through biogas in swine farming is effective, which can be used in rural productive system itself. (author)

  1. Swiss population-based reference data for six symptom validity tests

    Directory of Open Access Journals (Sweden)

    Peter Giger

    2013-01-01

    Full Text Available Los resultados encontrados en la evaluación de la validez de los síntomas (SVT deberían ser inmunes a las variables sociodemográficas. Así, los sujetos sanos y cooperadores deberían superar los tests de SVT. El ob- jetivo de este estudio es obtener datos de referencia de una serie de pruebas utilizadas en la evaluación de la validez de los síntomas, en una muestra representativa de 100 ciudadanos suizos, germano-hablantes, de entre 18 y 60 años: Medical Symptom Validity Test, Structured Inventory of Malingered Symptomatology, Amsterdam Short-Term Memory Test, Emotional Numbing Test, Reliable Digit Span y Maximum Span Forward. Los análisis de regresión múltiple reflejaron que las variables edad e inteligencia verbal afectaron a los resultados de varias de las pruebas, mientras que no fue así para las variables sexo y nivel educativo. La tasa de resultados positivos osciló entre el 1% (Emotional Numbing Test, Structured Inventory of Malin- gered Symptomatology y el 4% (Maximum Span Forward. Una cuestión relevante que se desprende de este estudio es si dichos resultados positivos en las muestras de referencia

  2. Feasibility of implementation of a "simplified, No-X-Ray, no-lead apron, two-catheter approach" for ablation of supraventricular arrhythmias in children and adults.

    Science.gov (United States)

    Stec, Sebastian; Śledź, Janusz; Mazij, Mariusz; Raś, Małgorzata; Ludwik, Bartosz; Chrabąszcz, Michał; Śledź, Arkadiusz; Banasik, Małgorzata; Bzymek, Magdalena; Młynarczyk, Krzysztof; Deutsch, Karol; Labus, Michał; Śpikowski, Jerzy; Szydłowski, Lesław

    2014-08-01

    Although the "near-zero-X-Ray" or "No-X-Ray" catheter ablation (CA) approach has been reported for treatment of various arrhythmias, few prospective studies have strictly used "No-X-Ray," simplified 2-catheter approaches for CA in patients with supraventricular tachycardia (SVT). We assessed the feasibility of a minimally invasive, nonfluoroscopic (MINI) CA approach in such patients. Data were obtained from a prospective multicenter CA registry of patients with regular SVTs. After femoral access, 2 catheters were used to create simple, 3D electroanatomic maps and to perform electrophysiologic studies. Medical staff did not use lead aprons after the first 10 MINI CA cases. A total of 188 patients (age, 45 ± 21 years; 17% 0.05), major complications (0% vs. 0%, P > 0.05) and acute (98% vs. 98%, P > 0.05) and long-term (93% vs. 94%, P > 0.05) success rates were similar in the "No-X-Ray" and control groups. Implementation of a strict "No-X-Ray, simplified 2-catheter" CA approach is safe and effective in majority of the patients with SVT. This modified approach for SVTs should be prospectively validated in a multicenter study. © 2014 Wiley Periodicals, Inc.

  3. Comparison of the Morel Emotional Numbing Test for Posttraumatic Stress Disorder to the Word Memory Test in neuropsychological evaluations.

    Science.gov (United States)

    Morel, Kenneth R

    2008-03-01

    The most commonly feigned cognitive and psychiatric disorders for survivors of traumatic injury are memory dysfunction and posttraumatic stress disorder (PTSD). The position of the National Academy of Neuropsychology is that symptom validity tests (SVTs) should be part of any comprehensive neuropsychological evaluation. In this article the Morel Emotional Numbing Test for Posttraumatic Stress Disorder (MENT), a SVT for PTSD, was compared to a SVT for memory, the Word Memory Test (WMT). Available archival data on 216 consecutive referrals for neuropsychological evaluations at the Veterans Affairs Tennessee Valley Healthcare System were reviewed. Of the total records reviewed 37 patients had been administered both the MENT and the WMT. The clinically recommended cutoff on the WMT was used as the main criterion to classify patients into two groups: simulating impairment or credible. The results indicated that the simulating impairment group had significantly more errors on the MENT than the credible group did (p <.0001). The criterion-related characteristics of the MENT in assessing response bias in relation to the WMT were confirmed Clinical and research implications of the utilization of the MENT are discussed in this study.

  4. Detecting feigned postconcussional and posttraumatic stress symptoms with the structured inventory of malingered symptomatology (SIMS).

    Science.gov (United States)

    Parks, Adam C; Gfeller, Jeffrey; Emmert, Natalie; Lammert, Hannah

    2017-01-01

    The Structured Inventory of Malingered Symptomatology (SIMS) is a standalone symptom validity test (SVT) designed as a screening measure to detect a variety of exaggerated psychological symptoms. A number of studies have explored the accuracy of the SIMS in litigious and clinical populations, yet few have examined the validity of the SIMS in detecting feigned symptoms of postconcussional disorder (PCD) and posttraumatic stress disorder (PTSD). The present study examined the sensitivity of the SIMS in detecting undergraduate simulators (N = 78) feigning symptoms of PCD, PTSD, and the comorbid presentation of both PCD and PTSD symptomatologies. Overall, the SIMS Total score produced the highest sensitivities for the PCD symptoms and PCD+PTSD symptoms groups (.89 and .85, respectively), and to a lesser extent, the PTSD symptoms group (.69). The Affective Disorders (AF) subscale was most sensitive to the PTSD symptoms group compared to the PCD and PCD+PTSD symptoms groups. Additional sensitivity values are presented and examined at multiple scale cutoff scores. These findings support the use of the SIMS as a SVT screening measure for PCD and PTSD symptom exaggeration in neuropsychological assessment.

  5. A new concept of vertically integrated pattern recognition associative memory

    International Nuclear Information System (INIS)

    Liu, Ted; Hoff, Jim; Deptuch, Grzegorz; Yarema, Ray

    2011-01-01

    Hardware-based pattern recognition for fast triggering on particle tracks has been successfully used in high-energy physics experiments for some time. The CDF Silicon Vertex Trigger (SVT) at the Fermilab Tevatron is an excellent example. The method used there, developed in the 1990's, is based on algorithms that use a massively parallel associative memory architecture to identify patterns efficiently at high speed. However, due to much higher occupancy and event rates at the LHC, and the fact that the LHC detectors have a much larger number of channels in their tracking detectors, there is an enormous challenge in implementing fast pattern recognition for a track trigger, requiring about three orders of magnitude more associative memory patterns than what was used in the original CDF SVT. Scaling of current technologies is unlikely to satisfy the scientific needs of the future, and investments in transformational new technologies need to be made. In this paper, we will discuss a new concept of using the emerging 3D vertical integration technology to significantly advance the state-of-the-art for fast pattern recognition within and outside HEP. A generic R and D proposal based on this new concept, with a few institutions involved, has recently been submitted to DOE with the goal to design and perform the ASIC engineering necessary to realize a prototype device. The progress of this R and D project will be reported in the future. Here we will only focus on the concept of this new approach.

  6. The Heavy Photon Search beamline and its performance

    Energy Technology Data Exchange (ETDEWEB)

    Baltzell, N.; Egiyan, H.; Ehrhart, M.; Field, C.; Freyberger, A.; Girod, F.-X.; Holtrop, M.; Jaros, J.; Kalicy, G.; Maruyama, T.; McKinnon, B.; Moffeit, K.; Nelson, T.; Odian, A.; Oriunno, M.; Paremuzyan, R.; Stepanyan, S.; Tiefenback, M.; Uemura, S.; Ungaro, M.; Vance, H.

    2017-04-04

    The Heavy Photon Search (HPS) is an experiment to search for a hidden sector photon, aka a heavy photon or dark photon, in fixed target electroproduction at the Thomas Jefferson National Accelerator Facility (JLab). The HPS experiment searches for the e+e- decay of the heavy photon with bump hunt and detached vertex strategies using a compact, large acceptance forward spectrometer, consisting of a silicon microstrip detector (SVT) for tracking and vertexing, and a PbWO4 electromagnetic calorimeter for energy measurement and fast triggering. To achieve large acceptance and good vertexing resolution, the first layer of silicon detectors is placed just 10 cm downstream of the target with the sensor edges only 500 μm above and below the beam. Placing the SVT in such close proximity to the beam puts stringent requirements on the beam profile and beam position stability. As part of an approved engineering run, HPS took data in 2015 and 2016 at 1.05 GeV and 2.3 GeV beam energies, respectively. This paper describes the beam line and its performance during that data taking.

  7. Metrology for New Generation Nuclear Power Plants - MetroFission

    International Nuclear Information System (INIS)

    Johansson, Lena; Dinsdale, Alan; Keightley, John; Filtz, Jean-Remy; Hay, Bruno; DeFelice, Pierino; Sadli, Mohamed; Plompen, Arjan; Heyse, Jan; Pomme, Stefaan; Cassette, Philippe

    2013-06-01

    MetroFission project has been looking at solving metrological problems related to a new generation of NPPs. The proposed Gen. IV NPPs are designed to run safely, make efficient use of natural resources, minimize the waste and maintain proliferation resistance. In order to reach these goals, the reactor operation involves higher temperatures, high-energy neutron fluence, different types of fuel where the minor actinides are included etc. The work has focused on improved temperature measurements, investigation of thermal properties of advanced materials, determination of new and relevant nuclear data and development of measurement techniques for radionuclides suitable for Gen. IV NPPs. The improved temperature measurement for nuclear power plant applications includes the development of a new Fe-C fixed point. Robust, repeatable and versatile cells have been constructed and compared with success among the project participants and their melting temperatures have been determined. Methodology of self-validating thermocouples has proven efficient at several fixed point temperatures using different designs. A practical acoustic thermometer has been tested at 1000 deg. C with success thanks to the use of innovative signal processing methods. Mo/Nb thermocouples have been obtained with different sheath materials and tested with the aim to achieve for the first time a reference function determined with the best possible uncertainties. Following reviews of designs and technology proposed for fourth generation nuclear plants effort within this project, with regards to thermal properties of advanced materials for nuclear design, has concentrated on provision of thermodynamic data to support the development of the sodium cooled fast reactor. Data has been critically assessed to represent the potential interaction between the Na coolant and the nuclear fuel taken to be based on (U, Pu)O 2 but incorporating minor actinides such as Np and Am. Data for the fission products and

  8. In vitro study of heat production during power reduction of equine mandibular teeth.

    Science.gov (United States)

    Allen, Martin L; Baker, Gordon J; Freeman, David E; Holmes, Kenneth R; Marretta, Sandra Manfra; Scoggins, R Dean; Constable, Peter

    2004-04-01

    To measure the amount of heat generated during 3 methods of equine dental reduction with power instruments. In vitro study. 30 premolar and molar teeth removed from mandibles of 8 equine heads collected at an abbatoir. 38-gauge copper-constantan thermocouples were inserted into the lingual side of each tooth 15 mm (proximal) and 25 mm (distal) from the occlusal surface, at a depth of 5 mm, which placed the tip close to the pulp chamber. Group-NC1 (n = 10) teeth were ground for 1 minute without coolant, group-NC2 (10) teeth were ground for 2 minutes without coolant, and group-C2 (10) teeth were ground for 2 minutes with water for coolant. Mean temperature increase was 1.2 degrees C at the distal thermocouple and 6.6 degrees C at the proximal thermocouple for group-NC1 teeth, 4.1 degrees C at the distal thermocouple and 24.3 degrees C at the proximal thermocouple for group-NC2 teeth, and 0.8 degrees C at the distal thermocouple and -0.1 degrees C at the proximal thermocouple for group-C2 teeth. In general, an increase of 5 degrees C in human teeth is considered the maximum increase before there is permanent damage to tooth pulp. In group-NC2 teeth, temperature increased above this limit by several degrees, whereas in group-C2 teeth, there was little or no temperature increase. Our results suggest that major reduction of equine teeth by use of power instruments causes thermal changes that may cause irreversible pulp damage unless water cooling is used.

  9. New sensor for measurement of low air flow velocity. Phase I final report

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Hashemian, M.; Riggsbee, E.T.

    1995-08-01

    The project described here is the Phase I feasibility study of a two-phase program to integrate existing technologies to provide a system for determining air flow velocity and direction in radiation work areas. Basically, a low air flow sensor referred to as a thermocouple flow sensor has been developed. The sensor uses a thermocouple as its sensing element. The response time of the thermocouple is measured using an existing in-situ method called the Loop Current Step Response (LCSR) test. The response time results are then converted to a flow signal using a response time-versus-flow correlation. The Phase I effort has shown that a strong correlation exists between the response time of small diameter thermocouples and the ambient flow rate. As such, it has been demonstrated that thermocouple flow sensors can be used successfully to measure low air flow rates that can not be measured with conventional flow sensors. While the thermocouple flow sensor developed in this project was very successful in determining air flow velocity, determining air flow direction was beyond the scope of the Phase I project. Nevertheless, work was performed during Phase I to determine how the new flow sensor can be used to determine the direction, as well as the velocity, of ambient air movements. Basically, it is necessary to use either multiple flow sensors or move a single sensor in the monitoring area and make flow measurements at various locations sweeping the area from top to bottom and from left to right. The results can then be used with empirical or physical models, or in terms of directional vectors to estimate air flow patterns. The measurements can be made continuously or periodically to update the flow patterns as they change when people and objects are moved in the monitoring area. The potential for using multiple thermocouple flow sensors for determining air flow patterns will be examined in Phase II

  10. Therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia and the risk factors for postoperative recurrence.

    Science.gov (United States)

    Li, Chunli; Jia, Libo; Wang, Zhenzhou; Niu, Ling; An, Xinjiang

    2018-05-01

    The present study investigated the therapeutic effect of radiofrequency ablation on children with supraventricular tachycardia (SVT), and explored the risk factors for postoperative recurrence. A total of 312 patients with pediatric SVT were selected in the Affiliated Children's Hospital of Xuzhou Medical University from April, 2011 to March, 2017. All the patients were subjected to radiofrequency ablation, and clinical data were retrospectively analyzed. Tilt table test was performed before and after treatment, and heart rate, systolic and diastolic blood pressure before and after treatment were compared. Plasma levels of D-dimer (D-D), platelet α-granule membrane protein (GMP-140) and thrombin-antithrombin III complex (TAT) were detected by enzyme-linked immunosorbent assay before treatment, immediately after radiofrequency oblation, and at 1, 3 and 7 days after treatment. Treatment outcomes were compared between the atrioventricular reentrant tachycardia (AVRT) and atrioventricular nodal reentrant tachycardia (AVNRT) groups. Risk factors for postoperative recurrence were analyzed. Supine position heart rate after treatment was not significantly different from that before treatment (P>0.05), while the upright position heart rate was significantly increased after treatment (P0.05). No significant difference in radiofrequency ablation rate, recurrence rate and incidence of complications were found between the AVRT and AVNRT groups (P>0.05). After radiofrequency, the levels of D-D, GMP-140 and TAT ablation showed an upward trend, but decreased at day 7 to reach preoperative levels. Logistic regression analysis revealed that residual slow pathway (OR=6.718, P=0.005) and inaccurate targeting (OR=2.815, P=0.007) were independent risk factors for postoperative recurrence (Pradiofrequency ablation can damage the cardiac vagal nerve, resulting in an increase in the heart rate after ablation during the course of the tilt table test and changed hemagglutination state

  11. Online track reconstruction at hadron colliders

    International Nuclear Information System (INIS)

    Amerio, Silvia; Bettini, Marco; Nicoletto, Marino; Crescioli, Francesco; Bucciantonio, Martina; DELL'ORSO, Mauro; Piendibene, Marco; VOLPI, Guido; Annovi, Alberto; Catastini, Pierluigi; Giannetti, Paola; Lucchesi, Donatella

    2010-01-01

    Real time event reconstruction plays a fundamental role in High Energy Physics experiments. Reducing the rate of data to be saved on tape from millions to hundreds per second is critical. In order to increase the purity of the collected samples, rate reduction has to be coupled with the capability to simultaneously perform a first selection of the most interesting events. A fast and efficient online track reconstruction is important to effectively trigger on leptons and/or displaced tracks from b-quark decays. This talk will be an overview of online tracking techniques in different HEP environments: we will show how H1 experiment at HERA faced the challenges of online track reconstruction implementing pattern matching and track linking algorithms on CAMs and FPGAs in the Fast Track Processor (FTT). The pattern recognition technique is also at the basis of the Silicon Vertex Trigger (SVT) at the CDF experiment at Tevatron: coupled to a very fast fitting phase, SVT allows to trigger on displaced tracks, thus greatly increasing the efficiency for the hadronic B decay modes. A recent upgrade of the SVT track fitter, the Giga-fitter, can perform more than 1 fit/ns and further improves the CDF online trigger capabilities at high luminosity. At SLHC, where luminosities will be 2 orders of magnitude greater than Tevatron, online tracking will be much more challenging: we will describe CMS future plans for a Level-1 track trigger and the Fast Tracker (FTK) processor at the ATLAS experiment, based on the Giga-fitter architecture and designed to provide high quality tracks reconstructed over the entire detector in time for a Level-2 trigger decision.luminosity. At SLHC, where luminosities will be 2 orders of magnitude greater than Tevatron, online tracking will be much more challenging: we will describe CMS future plans for a Level-1 track trigger and the Fast Tracker (FTK) processor at the Atlas experiment, based on the Giga-fitter architecture and designed to provide high

  12. [Skull vibratory test in partial vestibular lesions--influence of the stimulus frequency on the nystagmus direction].

    Science.gov (United States)

    Dumas, G; Perrin, P; Morel, N; N'Guyen, D Q; Schmerber, S

    2005-01-01

    Results of the skull vibratory test (SVT) in partial unilateral vestibular peripheral lesions (PUVL) are different from the results in total vestibular lesions (TUVL). To reveal a correlation between the results of the analysis of the skull vibratory nystagmus (SVN) horizontal component and the side of the lesion; to correlate these results with the stimulus frequency. To find out a predictive correlation between the SVN horizontal and vertical components and the topography of a vestibular lesion. To appreciate the degree of vestibular deafferentation (extended to high frequencies) provoked by gentamicin labyrinthectomy and its efficiency in Meniere's disease. 53 patients with a SVN and a PUVL were included and compared with 10 TUVL and 10 normal subjects. Protocol included a HST (2 Hz), a SVT at 30, 60 and 100 Hz and a caloric test. Recordings were performed with a 2D and 3D VNG device. In PUVL, SVN at 30, 60 and 100 Hz was obtained in 80, 90 and 90% of cases respectively. SVN is correlated with the side of the lesion at 30, 60 and 100 Hz respectively in 65%, 63%, 80% of cases. SVN is not correlated with the side of the lesion in 20% of Meniere's disease, in 8% of vestibular neuritis and in 6% of vestibular schwannoma. In PUVL HSN is correlated with the side of the lesion in 69% of cases. The direction of the HSN and of the SVN was different in 23% when the nystagmus attended at the same time for both tests. In PUVL the direction of the SVN is different at 100 Hz and 30 Hz in 16% of cases when they are concomittant on the same patient. After Gentamicine labyrinthectomy, the coherence of the results in caloric test, HSN and SVN (areflexy and lesional nystagmus beating toward the safe side) was correlated with the efficiency of the therapy. A SVN vertical component was met in 10% of PUVL (essentially in anterior canal dehiscence and few cases of partial labyrinthitis). The horizontal SVN SPV is significantly slower in PUVL than in TUVL patients (p=0.0004). The SVT

  13. Thermoelectric generator and method of forming same

    International Nuclear Information System (INIS)

    Wilson, K.T.

    1981-01-01

    A thermoelectric device is disclosed which comprises the formation of a multiplicity of thermocouples on a substrate in a narrow strip form, the thermocouples being formed by printing with first and second inks formed of suitable different powdered metals with a proper binder or flux. The thermocouples are formed in series and the opposed coupled areas are melted to form an intermingling of the two metals and the strips may be formed in substantial lengths and rolled onto a reel, or in relatively short strip form and disposed in a side-by-side abutting relationship in substantial numbers to define a generally rectangular panel form with opposed ends in electrical connection. The method of forming the panels includes the steps of feeding a suitable substrate, either in a continuous roll or sheet form, through first and second printers to form the series connected multiplicity of thermocouples thereon. From the printers the sheet or strip passes through a melter such as an induction furnace and from the furnace it passes through a sheeter, if the strip is in roll form. The sheets are then slit into narrow strips relative to the thermocouples, printed thereon and the strips are then formed into a bundle. A predetermined number of bundles are assembled into a panel form

  14. Thin film heat flux sensors for accurate transient and unidirectional heat transfer analysis

    International Nuclear Information System (INIS)

    Azerou, B; Garnier, B; Lahmar, J

    2012-01-01

    Heat flux measurement is needed in many heat transfer studies. For the best unbiased heat flux sensors (HFS), the heat flux is obtained using temperature measurements at different locations and also an inverse heat conduction method (function specification...) in order to calculate the heat flux. Systematic errors can come from the uncertainty in the wire thermocouples locations and from errors in the knowledge of distances between two consecutive wire thermocouples. The main idea in this work is to use thin film thermoresistances deposited on a flexible thin polymer substrate instead of wire thermocouples welded on metallic sample. The interest of using thin film thermoresistances instead of wire thermocouples is a lower disturbance due to the smaller thickness of the thin film sensors (typically less than 1μm) and a much better knowledge of the distances between the different thin film thermoresistances which are precisely defined in the mask used for the metallic thin film pattern fabrication. In this paper, we present the fabrication of the new heat flux sensor with thin film thermoresistances, the study of the effect of the self heating (due to Joule effect in thermoresistances) and the performances of this new HFS with the comparison with classical HFS using wire thermocouples. For this study, a symmetric experimental setup is used with metallic samples equipped with an etched foil heater and both classical and new HFS. For several heating conditions, it appears that a better accuracy is always obtained with the new HFS using thin film thermoresistances.

  15. Adiabatic surface thermometer for improved production braze quality

    International Nuclear Information System (INIS)

    Dittbenner, G.R.

    1975-01-01

    An adiabatic surface thermometer was developed to control automatically the critical temperature-time cycle of a production vacuum-brazing process. Investigations revealed that optimum braze-joint strength required precise control of the brazing temperature. Spot-welded thermocouples could not be used because the spot welds cause surface damage. This thermometer touches the surface and uses a differential thermocouple and heater to measure surface temperature without heat flow, thereby eliminating large errors caused by conduction losses common to conventional spring-loaded thermocouples. Temperatures in air or vacuum are measured to 800 0 C with errors less than 5 0 C. This thermometer has minimized the rejection of production parts, resulting in a cost saving to the U. S. Energy Research and Development Administration

  16. Temperature estimates from the Zircaloy oxidation kinetics in the α plus β phase region

    International Nuclear Information System (INIS)

    Olsen, C.S.

    1981-01-01

    Oxidation rates of Zircaloy in steam were measured at temperatures between 961 and 1264 K and for duration times between 25 and 1900 seconds in order to calculate, in conjunction with measurements from postirradiation metallographic examination, the prior peak temperatures of Zircaloy fuel rod cladding. These temperature estimates will be used in light water reactor research programs to assess (a) the accuracy of temperature measurements of fuel rod cladding peak temperatures from thermocouples attached to the surface during loss-of-coolant experiments (LOCEs), (b) the perturbation of the fuel rod cladding LOCE temperature history caused by the presence of thermocouples, and (c) the measurements of cladding azimuthal temperature gradients near the thermocouple locations

  17. Pyrolytic graphite gauge for measuring heat flux

    Science.gov (United States)

    Bunker, Robert C. (Inventor); Ewing, Mark E. (Inventor); Shipley, John L. (Inventor)

    2002-01-01

    A gauge for measuring heat flux, especially heat flux encountered in a high temperature environment, is provided. The gauge includes at least one thermocouple and an anisotropic pyrolytic graphite body that covers at least part of, and optionally encases the thermocouple. Heat flux is incident on the anisotropic pyrolytic graphite body by arranging the gauge so that the gauge surface on which convective and radiative fluxes are incident is perpendicular to the basal planes of the pyrolytic graphite. The conductivity of the pyrolytic graphite permits energy, transferred into the pyrolytic graphite body in the form of heat flux on the incident (or facing) surface, to be quickly distributed through the entire pyrolytic graphite body, resulting in small substantially instantaneous temperature gradients. Temperature changes to the body can thereby be measured by the thermocouple, and reduced to quantify the heat flux incident to the body.

  18. Magnetic disturbance effects in noise thermometry

    International Nuclear Information System (INIS)

    Fischer, M.

    1992-01-01

    Due to the very small measurement signals, a compensation process is used, which presupposes undisturbed signals of the measurement resistance and a compensation resistance as necessary conditions. There is a two-channel control for the measurement and compensation circuit, so that parasitic noise voltages from the incoming leads and the electronics can be eliminated by cross-correlation. The sensor which is designed as a combined thermocouple/noise thermometer sensor, permits continuous measurement of temperature by measuring the thermal voltages and the in situ calibration of the thermocouples at all times, which may have considerable drift of the thermal voltages, depending on environmental effects. Leads designed as thermocouples use ferromagnetic materials, in part. (orig./DG) [de

  19. Radiation sensor

    International Nuclear Information System (INIS)

    Brown, W.L.; Geronime, R.L.

    1977-01-01

    Radiation sensor and thermocouple, respectively, which can be used for reactor in-core instrumentation. The radiation sensor consists of an inconel conductor wire and rhodium emitter wire, the thermocouple of two intertwined alumel or chromel wires. Both are arranged in the center of a metal tube relative to which they are separated by an insulator made of SiO 2 fibers. This insulator is first introduced as a loose fabric between the radiation sensor and the thermocouple, respectively, and the metal tube and then compacted to a density of 35-73% of pure SiO 2 by drawing the tube. There is no need for soldering or welding. The insulation resistivity at room temperature ist between 10 14 and 10 15 ohms. (ORU) [de

  20. Measurement of droplet dynamics across grid spacer in mist cooling of subchannel of PWR

    International Nuclear Information System (INIS)

    Lee, S.L.; Sheen, H.J.; Cho, S.K.; Issapour, I.

    1984-01-01

    An experiment was conducted of the dynamics and heat transfer of a droplet-vapor mist flow across a test grid spacer in a flow channel of 2 x 2 electrically heated simulation fuel rods. Embedded thermocouples were used to measure the rod cladding temperature and an unshielded Chromel-Alumel thermocouple was transversed in the center of the subchannel to measure the temperature of the water and steam coolant phases at various axial locations. Thermocouples were also embedded in the test grid spacer. Optical measurements of the size and velocity distributions of droplets and the velocity distribution of the superheated steam were made by special laser-Doppler anemometry techniques through quartz glass windows immediately upstream and downstream of the test grid spacer. Experiments over a range of steam and injected water flow rates and rod heat flux have been performed and some representative results and discussions are presented

  1. Zirconium metal-water oxidation kinetics. I. Thermometry

    International Nuclear Information System (INIS)

    Cathcart, J.V.; McElroy, D.L.; Pawel, R.E.; Perkins, R.A.; Williams, R.K.; Yurek, G.J.

    1976-02-01

    A description is given of the thermometry techniques used in the Zirconium Metal--Water Oxidation Kinetics Program. Temperature measurements in the range 900 to 1500 0 C are made in three experimental systems: two oxidation apparatuses and the annealing furnace used in a corollary study of the diffusion of oxygen in β-Zircaloy. Carefully calibrated Pt vs Pt--10 percent Rh thermocouples are employed in all three apparatuses, while a Pt--6 percent Rh vs Pt-- 30 percent Rh thermocouple and an optical pyrometer are used in addition in the annealing furnace. Features of the experimental systems pertaining to thermocouple installation, temperature control, emf measurements, etc. are described, and potential temperature-measurement error sources are discussed in detail. The accuracy of the temperature measurements is analyzed

  2. Thermoelectric generator

    International Nuclear Information System (INIS)

    Purdy, D.L.

    1978-01-01

    The main components of a thermoelectric generator are housed in an evacuated cylindrical vessel. In the middle of it there is the radioactive heat source, e.g. 90 Sr or 238 Pu, enclosed by a gamma radiation shield. This one is surrounded by a heat-insulating screen from getter material or indicidual sheets of titanium. In the bottom of the screen there are arranged several thermocouples on a circle. The thermocouples themselves are contained within casings sealed gas-tight and filled with an inert gas, e.g. argon. By separating the internal space of the generator vessel from the thermocouple casings, made of e.g. n- respectively p-doped lead telluride cylinders, for both the optimal gas state may be obtained. (DG) [de

  3. Detailed analysis of coolant mixing in WWER-440 fuel assembly heads

    International Nuclear Information System (INIS)

    Toth, S.; Aszodi, A.

    2008-01-01

    Based on experiences of former validation and sensitivity studies, a CFD model for head part of real working fuel assemblies with pitch of 12.3 mm has been developed with the code ANSYS CFX. Calculations were performed for typical fuel assemblies used in the Paks NPP. Differences between the outlet average temperatures and thermocouple signals were determined. Effect of the mixing grid position on thermocouple signal was investigated also. Mixing was analyzed in details with using so-called mixing scalars and weight factors of the central tube and rod bundle regions for in-core thermocouple signal were determined. Sensitivity of the weight factors for pin power distribution and mixing grid position were investigated. (Authors)

  4. Flexible and foldable paper-substrate thermoelectric generator (teg)

    KAUST Repository

    Rojas, Jhonathan Prieto

    2017-08-24

    Flexible and foldable paper-substrate thermoelectric generators (TEGs) and methods for making the paper-substrate TEGs are disclosed. A method includes depositing a plurality of thermocouples in series on a paper substrate to create a paper-substrate TEG, wherein the plurality of thermocouples is deposited between two contact points of the paper-substrate TEG. The method may also include setting the power density and maximum achievable temperature gradient of the paper-substrate TEG by folding the paper-substrate TEG. A paper-substrate TEG apparatus may include a paper substrate and a plurality of thermocouples deposited in series on the paper substrate between two contact points of the paper-substrate TEG, wherein the power density and maximum achievable temperature gradient of the paper-substrate TEG is set by folding the paper-substrate TEG.

  5. Detector and Front-end electronics for ALICE and STAR silicon strip layers

    CERN Document Server

    Arnold, L; Coffin, J P; Guillaume, G; Higueret, S; Jundt, F; Kühn, C E; Lutz, Jean Robert; Suire, C; Tarchini, A; Berst, D; Blondé, J P; Clauss, G; Colledani, C; Deptuch, G; Dulinski, W; Hu, Y; Hébrard, L; Kucewicz, W; Boucham, A; Bouvier, S; Ravel, O; Retière, F

    1998-01-01

    Detector modules consisting of Silicon Strip Detector (SSD) and Front End Electronics (FEE) assembly have been designed in order to provide the two outer layers of the ALICE Inner Tracker System (ITS) [1] as well as the outer layer of the STAR Silicon Vertex Tracker (SVT) [2]. Several prototypes have beenproduced and tested in the SPS and PS beam at CERN to validate the final design. Double-sided, AC-coupled SSD detectors provided by two different manufacturers and also a pair of single-sided SSD have been asssociated to new low-power CMOS ALICE128C ASIC chips in a new detector module assembly. The same detectors have also been associated to current Viking electronics for reference purpose. These prototype detector modules are described and some first results are presented.

  6. ‘Far Away, So Close’

    DEFF Research Database (Denmark)

    Jensen, Pia Majbritt

    on transnational media distribution and reception has repeatedly shown that non-Anglophone content rarely exports outside its geo-linguistic region due to the perception that audiences in other regions would be too far removed culturally and linguistically. How, then, do we begin to account for the success...... of Danish language drama around the world? Through an analysis interviews with Sydney-based audiences of the three DR series Forbrydelsen, Borgen and Bron/Broen (coproduced with Swedish SVT), this paper lays out four main findings that elaborates – or even challenges – existing theories of televisual...... distribution and reception: 1. Preference for the authentic non-local story rather than preference for the local or American story. The respondents in many cases seem to prefer the good Danish story to the local or American story because it is different in a more authentic way to what they are accustomed...

  7. Assessment of atrial fibrillation and vulnerability in patients with Wolff-Parkinson-White syndrome using two-dimensional speckle tracking echocardiography.

    Science.gov (United States)

    Li, Jing-Jie; Wei, Fang; Chen, Ju-Gang; Yu, Yan-Wei; Gu, Hong-Yue; Jiang, Rui; Wu, Xiu-Li; Sun, Qian

    2014-01-01

    The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both Psyndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period.

  8. Characterization of the biomass of a hybrid anaerobic reactor (HAR with two types of support material during the treatment of the coffee wastewater

    Directory of Open Access Journals (Sweden)

    Vivian Galdino da Silva

    2013-06-01

    Full Text Available This study investigated the microbiology of a hybrid anaerobic reactor (HAR in the removal of pollutant loads. This reactor had the same physical structure of an UASB reactor, however with minifilters inside containing two types of support material: expanded clay and gravel. Two hydraulic retention times (HRT of 24h and 18h were evaluated at steady-state conditions, resulting in organic loading rates (OLR of 0.032 and 0.018 kgDBO5m-3d-1 and biological organic loading rates (BOLR of 0,0015 and 0.001 kgDBO5kgSVT- 1d¹, respectively. The decrease in concentration of organic matter in the influent resulted an endogenous state of the biomass in the reactor. The expanded clay was the best support material for biofilm attachment.

  9. Recent progress in the development of 3D deep n-well CMOS MAPS

    International Nuclear Information System (INIS)

    Traversi, G; Manghisoni, M; Re, V; Gaioni, L; Manazza, A; Ratti, L; Zucca, S

    2012-01-01

    In the deep n-well (DNW) monolithic active pixel sensor (MAPS) a full in-pixel signal processing chain is integrated by exploiting the triple well option of a deep submicron CMOS process. This work is concerned with the design and characterization of DNW MAPS fabricated in a vertical integration (3D) CMOS technology. 3D processes can be very effective in overcoming typical limitations of monolithic active pixel sensors. This paper discusses the main features of a new analog processor for DNW MAPS (ApselVI) in view of applications to the SVT Layer0 of the SuperB Factory. It also presents the first experimental results from the test of a DNW MAPS prototype in the GlobalFoundries 130 nm CMOS technology.

  10. Sign Inference for Dynamic Signed Networks via Dictionary Learning

    Directory of Open Access Journals (Sweden)

    Yi Cen

    2013-01-01

    Full Text Available Mobile online social network (mOSN is a burgeoning research area. However, most existing works referring to mOSNs deal with static network structures and simply encode whether relationships among entities exist or not. In contrast, relationships in signed mOSNs can be positive or negative and may be changed with time and locations. Applying certain global characteristics of social balance, in this paper, we aim to infer the unknown relationships in dynamic signed mOSNs and formulate this sign inference problem as a low-rank matrix estimation problem. Specifically, motivated by the Singular Value Thresholding (SVT algorithm, a compact dictionary is selected from the observed dataset. Based on this compact dictionary, the relationships in the dynamic signed mOSNs are estimated via solving the formulated problem. Furthermore, the estimation accuracy is improved by employing a dictionary self-updating mechanism.

  11. Double-labelled HIV-1 particles for study of virus-cell interaction

    International Nuclear Information System (INIS)

    Lampe, Marko; Briggs, John A.G.; Endress, Thomas; Glass, Baerbel; Riegelsberger, Stefan; Kraeusslich, Hans-Georg; Lamb, Don C.; Braeuchle, Christoph; Mueller, Barbara

    2007-01-01

    Human immunodeficiency virus (HIV) delivers its genome to a host cell through fusion of the viral envelope with a cellular membrane. While the viral and cellular proteins involved in entry have been analyzed in detail, the dynamics of virus-cell fusion are largely unknown. Single virus tracing (SVT) provides the unique opportunity to visualize viral particles in real time allowing direct observation of the dynamics of this stochastic process. For this purpose, we developed a double-coloured HIV derivative carrying a green fluorescent label attached to the viral matrix protein combined with a red label fused to the viral Vpr protein designed to distinguish between complete virions and subviral particles lacking MA after membrane fusion. We present here a detailed characterization of this novel tool together with exemplary live cell imaging studies, demonstrating its suitability for real-time analyses of HIV-cell interaction

  12. Dynamic VaR Measurement of Gold Market with SV-T-MN Model

    Directory of Open Access Journals (Sweden)

    Fenglan Li

    2017-01-01

    Full Text Available VaR (Value at Risk in the gold market was measured and predicted by combining stochastic volatility (SV model with extreme value theory. Firstly, for the fat tail and volatility persistence characteristics in gold market return series, the gold price return volatility was modeled by SV-T-MN (SV-T with Mixture-of-Normal distribution model based on state space. Secondly, future sample volatility prediction was realized by using approximate filtering algorithm. Finally, extreme value theory based on generalized Pareto distribution was applied to measure dynamic risk value (VaR of gold market return. Through the proposed model on the price of gold, empirical analysis was investigated; the results show that presented combined model can measure and predict Value at Risk of the gold market reasonably and effectively and enable investors to further understand the extreme risk of gold market and take coping strategies actively.

  13. The CDF online silicon vertex tracker

    International Nuclear Information System (INIS)

    Ashmanskas, W.

    2001-01-01

    The CDF Online Silicon Vertex Tracker reconstructs 2-D tracks by linking hit positions measured by the Silicon Vertex Detector to the Central Outer Chamber tracks found by the eXtremely Fast Tracker. The system has been completely built and assembled and it is now being commissioned using the first CDF run II data. The precision measurement of the track impact parameter will allow triggering on B hadron decay vertices and thus investigating important areas in the B sector, like CP violation and B s mixing. In this paper we briefly review the architecture and the tracking algorithms implemented in the SVT and we report on the performance of the system achieved in the early phase of CDF run II

  14. Hadron Collider Physics with Real Time Trajectory Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Annovi, Alberto [Univ. of Pisa (Italy)

    2005-01-01

    During last century experiments with accelerators have been extensively used to improve our understanding of matter. They are now the most common tool used to search for new phenomena in high energy physics. In the process of probing smaller distances and searching for new particles the center of mass energy has been steadily increased. The need for higher center of mass energy made hadron colliders the natural tool for discovery physics. Hadron colliders have a major drawback with respect to electron-positron colliders. As shown in fig. 1 the total cross section is several orders of magnitude larger than the cross section of interesting processes such as top or Higgs production. This means that, in order to observe interesting processes, it’s necessary to have collisions at very high rates and it becomes necessary to reject on-line most of the “non-interesting” events. In this thesis I have described the wide range of SVT applications within CDF.

  15. Thermoelectric Mixed Thick-/Thin Film Microgenerators Based on Constantan/Silver

    Directory of Open Access Journals (Sweden)

    Mirosław Gierczak

    2018-01-01

    Full Text Available This paper describes the design, manufacturing and characterization of newly developed mixed thick-/thin film thermoelectric microgenerators based on magnetron sputtered constantan (copper-nickel alloy and screen-printed silver layers. The thermoelectric microgenerator consists of sixteen thermocouples made on a 34.2 × 27.5 × 0.25 mm3 alumina substrate. One of thermocouple arms was made of magnetron-sputtered constantan (Cu-Ni alloy, the second was a Ag-based screen-printed film. The length of each thermocouple arm was equal to 27 mm, and their width 0.3 mm. The distance between the arms was equal to 0.3 mm. In the first step, a pattern mask with thermocouples was designed and fabricated. Then, a constantan layer was magnetron sputtered over the whole substrate, and a photolithography process was used to prepare the first thermocouple arms. The second arms were screen-printed onto the substrate using a low-temperature silver paste (Heraeus C8829A or ElectroScience Laboratories ESL 599-E. To avoid oxidation of constantan, they were fired in a belt furnace in a nitrogen atmosphere at 550/450 °C peak firing temperature. Thermoelectric and electrical measurements were performed using the self-made measuring system. Two pyrometers included into the system were used for temperature measurement of hot and cold junctions. The estimated Seebeck coefficient, α was from the range 35 − 41 µV/K, whereas the total internal resistances R were between 250 and 3200 ohms, depending on magnetron sputtering time and kind of silver ink (the resistance of a single thermocouple was between 15.5 and 200 ohms.

  16. Boil-off experiments with the EIR-NEPTUN Facility: Analysis and code assessment overview report

    International Nuclear Information System (INIS)

    Aksan, S.N.; Stierli, F.; Analytis, G.T.

    1992-03-01

    The NEPTUN data discussed in this report are from core uncovery (boil-off) experiments designed to investigate the mixture level decrease and the heat up of the fuel rod simulators above the mixture level for conditions simulating core boil-off for a nuclear reactor under small break loss-of-coolant accident conditions. The first series of experiments performed in the NEPTUN test facility consisted of ten boil-off (uncovery) and one adiabatic heat-up tests. In these tests three parameters were varied: rod power, system pressure and initial coolant subcooling. The NEPTUN experiments showed that the external surface thermocouples do not cause a significant cooling influence in the rods to which they are attached under boil-off conditions. The reflooding tests performed later on indicated that the external surface thermocouples have some effect during reflooding for NEPTUN electrically heated rod bundle. Peak cladding temperatures are reduced by about 30--40C and quench times occur 20--70 seconds earlier than rods with embedded thermocouples. Additionally, the external surface-thermocouples give readings up to 20 K lower than those obtained with internal surface thermocouples (in the absence of external thermocouples) in the peak cladding temperature zone. Some of the boil-off data obtained from the NEPTUN test facility are used for the assessment of the thermal-hydraulic transient computer codes. These calculations were performed extensively using the frozen version of TRAC-BD1/MOD1 (version 22). A limited number of assessment calculations were done with RELAP5/MOD2 (version 36.02). In this report the main results and conclusions of these calculations are presented with the identification of problem areas in relation to models relevant to boil-off phenomena. On the basis of further analysis and calculations done, changing some of the models such as the bubbly/slug flow interfacial friction correlation which eliminate some of the problems are recommended

  17. An investigation of temperature measurement methods in nuclear power plant reactor pressure vessel annealing

    International Nuclear Information System (INIS)

    Acton, R.U.; Gill, W.; Sais, D.J.; Schulze, D.H.; Nakos, J.T.

    1996-05-01

    The objective of this project was to provide an assessment of several methods by which the temperature of a commercial nuclear power plant reactor pressure vessel (RPV) could be measured during an annealing process. This project was a coordinated effort between DOE's Office of Nuclear Energy, Science and Technology; DOE's Light Water Reactor Technology Center at Sandia National Laboratories; and the Electric Power Research Institute's Non- Destructive Evaluation Center. Ball- thermocouple probes similar to those described in NUREG/CR-5760, spring-loaded, metal- sheathed thermocouple probes, and 1778 air- suspended thermocouples were investigated in experiments that heated a section of an RPV wall to simulate a thermal annealing treatment. A parametric study of ball material, emissivity, thermal conductivity, and thermocouple function locations was conducted. Also investigated was a sheathed thermocouple failure mode known as shunting (electrical breakdown of insulation separating the thermocouple wires). Large errors were found between the temperature as measured by the probes and the true RPV wall temperature during heat-up and cool-down. At the annealing soak temperature, in this case 454 degrees C [850'F], all sensors measured the same temperature within about ±5% (23.6 degrees C [42.5 degrees F]). Because of these errors, actual RPV wall heating and cooling rates differed from those prescribed (by up to 29%). Shunting does not appear to be a problem under these conditions. The large temperature measurement errors led to the development of a thermal model that predicts the RPV wall temperature from the temperature of a ball- probe. Comparisons between the model and the experimental data for ball-probes indicate that the model could be a useful tool in predicting the actual RPV temperature based on the indicated ball- probe temperature. The model does not predict the temperature as well for the spring-loaded and air suspended probes

  18. A review of the safety aspects of radio frequency ablation

    Directory of Open Access Journals (Sweden)

    Abhishek Bhaskaran

    2015-09-01

    Full Text Available In light of recent reports showing high incidence of silent cerebral infarcts and organized atrial arrhythmias following radiofrequency (RF atrial fibrillation (AF ablation, a review of its safety aspects is timely. Serious complications do occur during supraventricular tachycardia (SVT ablations and knowledge of their incidence is important when deciding whether to proceed with ablation. Evidence is emerging for the probable role of prophylactic ischemic scar ablation to prevent VT. This might increase the number of procedures performed. Here we look at the various complications of RF ablation and also the methods to minimize them. Electronic database was searched for relevant articles from 1990 to 2015. With better awareness and technological advancements in RF ablation the incidence of complications has improved considerably. In AF ablation it has decreased from 6% to less than 4% comprising of vascular complications, cardiac tamponade, stroke, phrenic nerve injury, pulmonary vein stenosis, atrio-esophageal fistula (AEF and death. Safety of SVT ablation has also improved with less than 1% incidence of AV node injury in AVNRT ablation. In VT ablation the incidence of major complications was 5–11%, up to 3.4%, up to 1.8% and 4.1–8.8% in patients with structural heart disease, without structural heart disease, prophylactic ablations and epicardial ablations respectively. Vascular and pericardial complications dominated endocardial and epicardial VT ablations respectively. Up to 3% mortality and similar rates of tamponade were reported in endocardial VT ablation. Recent reports about the high incidence of asymptomatic cerebral embolism during AF ablation are concerning, warranting more research into its etiology and prevention.

  19. Inflammation markers are associated with metabolic syndrome and ventricular arrhythmia in patients with coronary artery disease

    Directory of Open Access Journals (Sweden)

    Krzysztof Safranow

    2016-02-01

    Full Text Available Background: Inflammation plays a major role in the development and progression of atherosclerosis and coronary artery disease (CAD. Inflammation markers, including white blood cell (WBC count, C-reactive protein (CRP and interleukin-6 (IL-6, are widely used for cardiovascular risk prediction. The aim of the study was to establish factors associated with WBC, CRP and IL-6 in patients with CAD. Two functional polymorphisms in genes encoding enzymes participating in adenosine metabolism were analyzed (C34T AMPD1, G22A ADA. Methods: Plasma concentrations of IL-6 were measured using high-sensitivity ELISA kits, and the nephelometric method was used for high-sensitivity CRP (hs-CRP measurement in 167 CAD patients. Results: Presence of metabolic syndrome (MS and its components, presence of heart failure, severity of CAD symptoms, severe past ventricular arrhythmia (sustained ventricular tachycardia [sVT] or ventricular fibrillation [VF], lower left ventricle ejection fraction, higher left ventricle mass index, higher end-diastolic volume and higher number of smoking pack-years were significantly associated with higher WBC, CRP and IL-6. Strong associations with arrhythmia were observed for IL-6 (median 3.90 vs 1.89 pg/mL, p<0.00001 and CRP concentration (6.32 vs 1.47 mg/L, p=0.00009, while MS was associated most strongly with IL-6. CRP and IL-6 were independent markers discriminating patients with sVT or VF. There were no associations between AMPD1 or ADA genotypes and inflammation markers. Conclusions: WBC, CRP and IL-6 are strongly associated with components of the metabolic syndrome. Their strong association with life-threatening ventricular arrhythmia emphasizes the proarrhythmic role of inflammation in the increased cardiovascular risk of CAD patients.

  20. A case of near-fatal flecainide overdose in a neonate successfully treated with sodium bicarbonate.

    Science.gov (United States)

    Jang, David H; Hoffman, Robert S; Nelson, Lewis S

    2013-04-01

    Flecainide is a class IC antidysrhythmic primarily indicated for ventricular dysrhythmias and supraventricular tachycardia (SVT). Class IC antidysrhythmic overdose has a reported mortality of 22%, and death results from dysrhythmias and cardiovascular collapse. We report a near-fatal flecainide overdose in an 18-day-old treated successfully with sodium bicarbonate. An 18-day-old, 2 weeks premature, 4-kg boy developed persistently high heart rates (220-240 beats/min) and electrocardiographic changes consistent with SVT. There was minimal response to vagal maneuvers, adenosine, and esmolol, and a transthoracic echocardiogram showed no underlying structural abnormality. The patient was then started on flecainide 4 mg orally every 8 h (Q8h). After the fourth dose he developed lethargy, cold clammy skin, and a heart rate of 40 beats/min with no palpable pulse. The patient was given 0.1 mg of atropine intravenously, with an increase of the heart rate to 160 beats/min. The child's cardiac monitor revealed a wide-complex tachycardia with left bundle branch morphology, with associated pallor and poor capillary refill. Sodium bicarbonate was administered intravenously due to suspected flecainide toxicity. Approximately 5 min after intravenous administration of 10 mEq of 8.4% sodium bicarbonate twice, his rhythm converted to a narrow-complex tachycardia. A serum flecainide concentration was 1360 μg/L (therapeutic, 200-1000 μg/L) drawn 1 h before the cardiac arrest. It was later discovered that a twofold dosing error occurred: the patient received 8 mg Q8h instead of 4 mg Q8h for four doses. Flecainide toxicity in children is rare, especially in neonates. It is important for clinicians to be able to identify and treat this uncommon poisoning. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Performances of the Si microstrip detector of the STAR experiment at RHIC; Performances du detecteur en silicium a micropistes de l'experience STAR a RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Bouchet, J

    2007-10-15

    The Silicon Strip Detector (SSD) is the fourth layer of detector using a double-sided microstrip technology of the STAR experiment at RHIC, completing STAR's inner tracking device. The goal of STAR is to study heavy ions collisions in order to probe the existence of the quark gluon plasma (QGP), a deconfined state of nuclear matter. Strangeness enhancement, such as {kappa}{sub S}{sup 0}, {lambda}, {xi} and {omega}, for particles production, has been proposed to sign the formation of QGP. Then precise measurement of secondary vertices is needed. The SSD will also permit an attempt to use the inner tracking device to measure charm and beauty with direct topological identification. It was proposed to enhance the STAR tracking capabilities by providing a better connection between reconstructed tracks in the main tracking device (TPC) and the initial vertex detector (SVT). In this thesis, we will present the intrinsic performances of the SSD and its impact on the inner tracking system performances by studying Cu-Cu collisions occurred at RHIC in 2005. We show that the SSD detector has excellent performances in terms of resolution: (945 {+-} 18) {mu}m in azimuth and (1021 {+-} 13) {mu}m along the beam axis. For the final result when SSD is associated to the SVT the resolutions are (281 {+-} 1) {mu}m and (213 {+-} 0.8) {mu}m in azimuth and along the beam axis respectively. The resolution reached by the addition of the Silicon Vertex detectors of STAR will allow the search for rare particles like charm and beauty, which have a decay-length of the order of hundred microns.

  2. Metoclopramide-induced cardiac arrest

    Directory of Open Access Journals (Sweden)

    Martha M. Rumore

    2011-11-01

    Full Text Available The authors report a case of cardiac arrest in a patient receiving intravenous (IV metoclopramide and review the pertinent literature. A 62-year-old morbidly obese female admitted for a gastric sleeve procedure, developed cardiac arrest within one minute of receiving metoclopramide 10 mg via slow intravenous (IV injection. Bradycardia at 4 beats/min immediately appeared, progressing rapidly to asystole. Chest compressions restored vital function. Electrocardiogram (ECG revealed ST depression indicative of myocardial injury. Following intubation, the patient was transferred to the intensive care unit. Various cardiac dysrrhythmias including supraventricular tachycardia (SVT associated with hypertension and atrial fibrillation occurred. Following IV esmolol and metoprolol, the patient reverted to normal sinus rhythm. Repeat ECGs revealed ST depression resolution without pre-admission changes. Metoclopramide is a non-specific dopamine receptor antagonist. Seven cases of cardiac arrest and one of sinus arrest with metoclopramide were found in the literature. The metoclopramide prescribing information does not list precautions or adverse drug reactions (ADRs related to cardiac arrest. The reaction is not dose related but may relate to the IV administration route. Coronary artery disease was the sole risk factor identified. According to Naranjo, the association was possible. Other reports of cardiac arrest, severe bradycardia, and SVT were reviewed. In one case, five separate IV doses of 10 mg metoclopramide were immediately followed by asystole repeatedly. The mechanism(s underlying metoclopramide’s cardiac arrest-inducing effects is unknown. Structural similarities to procainamide may play a role. In view of eight previous cases of cardiac arrest from metoclopramide having been reported, further elucidation of this ADR and patient monitoring is needed. Our report should alert clinicians to monitor patients and remain diligent in surveillance and

  3. Feedback to providers improves evidence-based implantable cardioverter-defibrillator programming and reduces shocks.

    Science.gov (United States)

    Silver, Marc T; Sterns, Laurence D; Piccini, Jonathan P; Joung, Boyoung; Ching, Chi-Keong; Pickett, Robert A; Rabinovich, Rafael; Liu, Shufeng; Peterson, Brett J; Lexcen, Daniel R

    2015-03-01

    Implantable cardioverter-defibrillator (ICD) shocks are associated with increased anxiety, health care utilization, and potentially mortality. The purpose of the Shock-Less Study was to determine if providing feedback reports to physicians on their adherence to evidence-based shock reduction programming could improve their programming behavior and reduce shocks. Shock-Less enrolled primary prevention (PP) and secondary prevention (SP) ICD patients between 2009 and 2012 at 118 study centers worldwide and followed patients longitudinally after their ICD implant. Center-specific therapy programming reports (TPRs) were delivered to each center 9 to 12 months after their first enrollment. The reports detailed adherence to evidence-based programming targets: number of intervals to detect ventricular fibrillation (VF NID), longest treatment interval (LTI), supraventricular tachycardia (SVT) discriminators (Wavelet, PR Logic), SVT limit, Lead Integrity Alert (LIA), and antitachycardia pacing (ATP). Clinicians programmed ICDs at their discretion. The primary outcome measure was the change in utilization of evidence-based shock reduction programming before (phase I, n = 2694 patients) and after initiation of the TPR (phase II, n = 1438 patients). Patients implanted after feedback reports (phase II) were up to 20% more likely to have their ICDs programmed in line with evidence-based shock reduction programming (eg, VF NID in PP patients 30/40 in 33.5% vs 18.6%, P programming feedback reports improves adherence to evidence-based shock reduction programming and is associated with lower risk of ICD shocks. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  4. Furnace testing of electrical and pipe-penetration seals based on foamed silicone elastomer: 60, 90, and 120-minute fire ratings

    International Nuclear Information System (INIS)

    Brown, A.

    1979-03-01

    Fire tests of foamed silicone seals for electrical and pipe penetrations have been performed using a furnace with temperature control as heat source. The tests were performed in principle in accordance with the requirements of NORDTEST 5A (ISO 834). The purpose of the tests was to obtain appropriate fire ratings for different seal thicknesses. The report covers. - Description of material used to prepare the seals and method of application - Description of furnace test assembly and method of performing test - Listing of penetrating elements and of the thermocouple array used to measure temperature - Curves of thermocouple readouts and photographs of seals during and after completion of the test. (author)

  5. System for improving measurement accuracy of transducer by measuring transducer temperature and resistance change using thermoelectric voltages

    Science.gov (United States)

    Anderson, Karl F. (Inventor); Parker, Allen R., Jr. (Inventor)

    1993-01-01

    A constant current loop measuring system measures a property including the temperature of a sensor responsive to an external condition being measured. The measuring system includes thermocouple conductors connected to the sensor, sensing first and second induced voltages responsive to the external condition. In addition, the measuring system includes a current generator and reverser generating a constant current, and supplying the constant current to the thermocouple conductors in forward and reverse directions generating first and second measured voltages, and a determining unit receiving the first and second measured voltages from the current generator and reverser, and determining the temperature of the sensor responsive to the first and second measured voltages.

  6. The design of electrical heater pins to simulate transient dryout and post-dryout of water reactor fuel

    International Nuclear Information System (INIS)

    Burgess, M.H.; Butcher, A.A.; Sidoli, J.E.A.

    1978-11-01

    A theoretical assessment of indirect and direct filled heater simulations of nuclear reactor fuel pins is described. For reasons of fast temperature response, a direct unfilled heater, with thermocouples buried in the walls, is recommended for studies of Loss-of-Coolant Accidents leading to dryout, post-dryout and rewetting. A design of heater pins, for use in SGHWR or PWR experiments, and compatible with existing 9MW power supplies, is described. Experiments to confirm collapse pressure calculations at 1000 0 C and thermocouple response times are also reported. (author)

  7. Report on series 3 reflood experiment

    International Nuclear Information System (INIS)

    Murao, Yoshio; Iguchi, Tadashi; Sudoh, Takashi; Sudo, Yukio; Sugimoto, Jun

    1977-03-01

    Series 3 reflood experiment was carried out from December 1975 to January 1976. The purpose was to confirm temperature response and durability of the improved thermocouple installation and to examine system effect with parameters, flow housing temperature and primary loop flow resistance. The results are : 1) The improved thermocouples installation still has some problems, but is generally satisfactory up to 1000 0 C. 2) The flow housing temperature has large influence on the reflood phenomena, especially oscillation. 3) The primary loop resistance determines the flooding rate, and so influences the reflood phenomena. (auth.)

  8. Technique of measuring and evaluating the R3E dia. 112 experimental fuel element

    International Nuclear Information System (INIS)

    Stanc, S.; Badiar, S.

    1974-10-01

    The charging is considered of the R3E experimental fuel element having a diameter of 112 mm which will serve the simultaneous temperature measurement on 15 sites and neutron flux measurement on 7 sites aimed at verifying the improved R3-type fuel element with extended cladding and a new toroidal spacing. The temperature will be measured using jacket thermocouples while neutron flux will be measured by self-powered detectors. The methods are described of checking the measuring chain by determining the loop resistance of the thermocouples and SPN detectors in order to verify the correctness of the measured data. (J.B.)

  9. Gamma thermometer allowing absolute and differential temperature measurements

    International Nuclear Information System (INIS)

    Bottin, P.; Schley, R.

    1985-01-01

    The gamma thermometer comprises an external envelope containing a cylindrical rod with a central bore and, thick and thin parts defining insulating chambers, at least one thermocouple set in the said central bore; the thermocouple has three junctions connected to one of their end parts by a junction at the level of a thin part, while one at least of the wires comprises two elements made of different materials connected by a junction at the level of a thick part. The present invention applies more particularly for detecting level of the coolant in a nuclear reactor [fr

  10. Estimation of piping temperature fluctuations based on external strain measurements

    International Nuclear Information System (INIS)

    Morilhat, P.; Maye, J.P.

    1993-01-01

    Due to the difficulty to carry out measurements at the inner sides of nuclear reactor piping subjected to thermal transients, temperature and stress variations in the pipe walls are estimated by means of external thermocouples and strain-gauges. This inverse problem is solved by spectral analysis. Since the wall harmonic transfer function (response to a harmonic load) is known, the inner side signal will be obtained by convolution of the inverse transfer function of the system and of the strain measurement enables detection of internal temperature fluctuations in a frequency range beyond the scope of the thermocouples. (authors). 5 figs., 3 refs

  11. Low pressure lithium condensation

    International Nuclear Information System (INIS)

    Wadkins, R.P.; Oh, C.H.

    1985-01-01

    A low pressure experiment to evaluate the laminar film condensation coefficients of lithium was conducted. Some thirty-six different heat transfer tests were made at system pressures ranging from 1.3 to 26 Pa. Boiled lithium was condensed on the inside of a 7.6-cm (ID), 409 stainless-steel pipe. Condensed lithium was allowed to reflux back to the pool boiling region below the condensing section. Fourteen chromel/alumel thermocouples were attached in various regions of the condensing section. The thermocouples were initially calibrated with errors of less than one degree Celsius

  12. Dynamics of Supercritical Flows

    Science.gov (United States)

    2012-08-26

    composition. In some liquid rocket engines, gas-turbines, and diesel engines the fuel and/or oxidizer in the injector may be at a pressure greater than...measurements at the exit-plane of the injector required great care. The thermocouples were individually calibrated against a precision Pt-RTD as described in...thermocouple used to measure the exit-plane temperature was calibrated using a precision Pt-RTD. Because of the small size of the injector (D1 = 0.508 mm), a

  13. Thermography Used to Test Conductivity of Carbon Based Cloth

    Science.gov (United States)

    Craven, Paul

    2012-01-01

    Testing of the ability of carbon fiber to radiatively cool a heat source. The carbon fibers are attached to a heat source. The heat conducts into the fiber than along the fiber away from the heat source. The test are done in a vacuum chamber (10-5 Torr typical). The IR camera is viewing the fiber through a ZnSe window. A thermocouple (TC) in contact with the fiber is at the top right hand side of the area of interest and one is near the bottom. Thin shielding fins, seen edge on, are just above the top thermocouple.

  14. Self-Concept Disconfirmation, Psychological Distress, and Marital Happiness.

    Science.gov (United States)

    Schafer, Robert B.; And Others

    1996-01-01

    Uses self-verification and self-discrepancy theories to test a model of subjective and objective self-disconfirmation, self-efficacy, depression, and marital happiness. Expands issues of self-validation by evaluating self-efficacy in the relationship between self-disconfirmation and depression, and the effect of self-concept disconfirmation of…

  15. 49 CFR 236.903 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... the site-specific application programs, run timers, read inputs, drive outputs, perform self... validation process is to determine “whether the correct product was built.” Verification means the process of... established at the start of that phase. The goal of the verification process is to determine “whether the...

  16. "@Work in Cyberspace": Exploring Practitioner Use of the PRForum.

    Science.gov (United States)

    Thomsen, Steven R.

    1996-01-01

    Explores the impact of PRForum, an Internet newsgroup, on the public relations community by examining the nature, function, and content of online exchanges. Finds that PRForum is used for three functions: to facilitate the exchange of information; to create a forum for debate on issues; and to cultivate a sense of self-validation on personal and…

  17. Viking Afterbody Heating Computations and Comparisons to Flight Data

    Science.gov (United States)

    Edquist, Karl T.; Wright, Michael J.; Allen, Gary A., Jr.

    2006-01-01

    Computational fluid dynamics predictions of Viking Lander 1 entry vehicle afterbody heating are compared to flight data. The analysis includes a derivation of heat flux from temperature data at two base cover locations, as well as a discussion of available reconstructed entry trajectories. Based on the raw temperature-time history data, convective heat flux is derived to be 0.63-1.10 W/cm2 for the aluminum base cover at the time of thermocouple failure. Peak heat flux at the fiberglass base cover thermocouple is estimated to be 0.54-0.76 W/cm2, occurring 16 seconds after peak stagnation point heat flux. Navier-Stokes computational solutions are obtained with two separate codes using an 8- species Mars gas model in chemical and thermal non-equilibrium. Flowfield solutions using local time-stepping did not result in converged heating at either thermocouple location. A global time-stepping approach improved the computational stability, but steady state heat flux was not reached for either base cover location. Both thermocouple locations lie within a separated flow region of the base cover that is likely unsteady. Heat flux computations averaged over the solution history are generally below the flight data and do not vary smoothly over time for both base cover locations. Possible reasons for the mismatch between flight data and flowfield solutions include underestimated conduction effects and limitations of the computational methods.

  18. State-of-the-art for liquid-level measurements applied to in-vessel coolant level for nuclear reactors

    International Nuclear Information System (INIS)

    Anderson, R.L.

    1980-01-01

    The TMI-2 accident indicated that a direct indication of the liquid level in the reactor vessel would have told the operators that the core was being uncovered. This state-of-the-cost survey covered the following methods: heated thermocouple, differential pressure, ultrasonic, capacitance, microwave, time-domain reflectometry, and externally mounted radiation detectors

  19. Observation of Meyer–Neldel rule in thermally activated Poole ...

    Indian Academy of Sciences (India)

    to their atomic percentages and were sealed in a quartz ampoule (length ~5 cm and internal dia. ~8 mm) in a ... The quenched sample was taken out by breaking the quartz ampoules. The glassy nature of the ... and the temperature measured by a calibrated copper–constantan thermocouple mounted very near to the films.

  20. Optical, thermal and phase transition studies in Sn1–xGexTe

    Indian Academy of Sciences (India)

    Unknown

    (Perkin Elmer) that is a quartz crystal oscillator for the primary frequency standard is employed. Like many other choppers, the chopping frequency can be controlled ... ing element a thermocouple is attached for temperature measurements. The actual PA cell, which is used for the measurements, is shown in figure 2.

  1. Optical band gap of Sn0⋅2Bi1⋅8Te3 thin films

    Indian Academy of Sciences (India)

    Unknown

    tors, thermocouples, thermo coolers and IR sensors with the best figure of merit near room temperature (Roy et al. 1978; Jeon et al 1981; Rowe and Bandari 1981; Good- ... pressure used to seal the quartz ampoules containing the charge was of the order of 10–5 Pa. The sealed ampoule was kept in an alloy mixing furnace, ...

  2. Fulltext PDF

    Indian Academy of Sciences (India)

    Pt-100 thermocouple. In general, sintered ceramic samples have large number of closed and open pores inside and on their surface and ... pulse generated by a pulse oscillator was applied to quartz transducer. The acoustic pulses were converted into electrical signals by the receiving transducer. The output signal was ...

  3. Dielectric relaxation in glassy Se75In25−xPbx alloys

    Indian Academy of Sciences (India)

    to their atomic percentages and were sealed in quartz ampoules (length ~5 cm and internal dia. ~8 mm) in vacuum ... samples were taken out by breaking the quartz ampoules. The glassy nature of the ... measured with the help of a calibrated copper–constantan thermocouple mounted very near to the sample, which could ...

  4. Preliminary study of temperature measurement techniques for Stirling engine reciprocating seals

    Science.gov (United States)

    Wilcock, D. F.; Hoogenboom, L.; Meinders, M.; Winer, W. O.

    1981-01-01

    Methods of determining the contact surface temperature in reciprocating seals are investigated. Direct infrared measurement of surface temperatures of a rod exiting a loaded cap seal or simulated seal are compared with surface thermocouple measurements. Significant cooling of the surface requires several milliseconds so that exit temperatures may be considered representative of internal contact temperatures.

  5. 46 CFR 164.008-3 - Testing procedure.

    Science.gov (United States)

    2010-10-01

    ... control. (1) The furnace temperature shall be determined by at least four mineral insulated thermocouples... further definition of the time-temperature curve, see Appendix I of the ASTM Standard E119, “Fire Tests of... openings are formed during the test, an ignition test as prescribed in § 164.008-4(b) shall take place...

  6. Development and research of in-core transducers at IAE (Institute of Atomic Energy)

    International Nuclear Information System (INIS)

    Huang Yucai; Qian Shunfa; Jia Guozhen

    1989-10-01

    The development of in-core transducers at IAE (Institute of Atomic Energy) and their applications in in-pile fuel assembly test are mentioned. These transducers include mainly tubed tungsten-rhenium thermocouple assembly, displacement transducer of linear variable differential transformer, pressure transducer of membrane type, gamma thermometer, turbine flow meter, self-powered neutron detector etc

  7. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  8. Neurological complications after 434 MHz microwave hyperthermia of the rat lumbar region including the spinal cord

    NARCIS (Netherlands)

    Franken, N. A.; de Vrind, H. H.; Sminia, P.; Haveman, J.; Troost, D.; Gonzalez Gonzalez, D.

    1992-01-01

    Hyperthermia was applied in the region of the vertebral column from the second to the fifth lumbar vertebra using a ring-shaped 434 MHz microwave radiator. In all experiments temperatures were measured at a 'reference' thermocouple which was placed against the fourth lumbar vertebra. After 60 min of

  9. Evaluation and Testing of the Suitability of a Coal-Based Jet Fuel

    Science.gov (United States)

    2008-06-01

    with a total wattage of 7980 watts. Each oven section has two K type thermocouples per zone with Inconel sheathed spring loaded bayonet type mounts...also exceeded the thermal stability goals (525°F bulk and 625 °F WWT) for the JP-8+225 fuel program. Tests were conducted on a JP-8 fuel to compare

  10. Method for producing evaporation inhibiting coating for protection of silicon--germanium and silicon--molybdenum alloys at high temperatures in vacuum

    Science.gov (United States)

    Chao, P.J.

    1974-01-01

    A method is given for protecting Si--Ge and Si-- Mo alloys for use in thermocouples. The alloys are coated with silicon to inhibit the evaporation of the alloys at high tempenatures in a vacuum. Specific means and methods are provided. (5 fig) (Official Gazette)

  11. Printing Functional 3D Microdevices by Laser-Induced Forward Transfer

    NARCIS (Netherlands)

    Luo, Jun; Pohl, R.; Qi, Lehua; Römer, G.R.B.E.; Sun, Chao; Lohse, Detlef; Visser, C.W.

    2017-01-01

    Slender, out-of-plane metal microdevices are made in a new spatial domain, by using laser-induced forward transfer (LIFT) of metals. Here, a thermocouple with a thickness of 10 µm and a height of 250 µm, consisting of platinum and gold pillars is demonstrated. Multimaterial LIFT enables

  12. A capacitive rf power sensor based on mems technology

    NARCIS (Netherlands)

    Fernandez, L.J.

    2005-01-01

    Existing power sensors for RF signals are based on thermistors, diodes and thermocouples. These power sensors are used as terminating devices and therefore they dissipate the complete incoming signal. Furthermore, new telecommunication systems require low weight, volume and power consumption and a

  13. Welding of sule elements for nuclear reactors with solid state YAG laser using instrumentated testing equipments

    International Nuclear Information System (INIS)

    Bourgault, F.; Lacoste, J.; Schley, R.; Kluzinski, C.; Piednoir, P.

    1985-09-01

    The instrumentation of the equipment for carrying out safety tests on fuel elements for nuclear reactors requires special thermocouples adapted to the prevailing agressive medium. The investigations described deal essentially with the operational and metallurgical weldability tests out on the safety test zircaloy piping in the pressurized water circuit (PHEBUS-programme) [fr

  14. Influence of temperature measurement accuracy and reliability on WWER-440 reactor operation

    International Nuclear Information System (INIS)

    Petenyi, V.; Ricany, J.

    2001-01-01

    The WWER-440 reactor power is controlled by coolant heat-up measurements installed on hot and cold circulation loops (enthalpy rise). For power distribution determination the thermocouples installed in reactor vessel above the fuel assemblies are mainly utilised. The paper shortly presents some interesting observations of temperature measurements influencing the reactor power operation of revealed changes in reactor core behaviour. (Authors)

  15. Experimental Investigation on an Energy Efficient Solar Tunnel Dryer

    OpenAIRE

    M. R. Seshan Ram

    2012-01-01

    The research determines the effectiveness of the solar tunnel dryer developed and the product dried in the device is superior in quality and also it is compatible with branded products available in the market. The study also determines Acetamide as Phase Key words: Solar Tunnel Dryer, Acetamide as Phase Change Materials, Conversion into Thermal Energy, Thermocouple, and Pyranometer

  16. Keeping reactors on the road

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    A description of the repair package developed by Marchwood Engineering Laboratories used for remotely reinforcing thermocouple support tubes at the Oldbury Magnox station is given. A system giving improved access to constrained areas by sterophotography is briefly discussed. The use of holography as an inspection tool is also outlined. (author)

  17. Evaluation of temperature variation in pulp chamber after high power diode laser irradiation (λ=830 nm) on dental enamel: 'in vitro' study

    International Nuclear Information System (INIS)

    Macri, Rodrigo Teixeira

    2001-01-01

    The aim of this study was to observe the variation of temperature in the pulp chamber caused by irradiation of a commercial diode laser operating in continuous wave with wavelength 830 nm over the dental enamel. In the first part of this study, two types of tooth models were tested: 3,5 mm slice and whole tooth. In the second part, we irradiated the buccal si de of the enamel in 2 primary lower incisors from cattle with Opus 10 diode laser for 10 s with power levels of 1 W and 2 W, always using an absorber. Two thermocouples were used. The first one was inserted in the dentin wall closest to the irradiation site, while the second was inserted in the middle of the pulp chamber. It was observed that the thermocouples registered different temperatures. Always, the dentin thermocouple registered higher temperatures. Considering the dentin records, the irradiation of 1 W for 10 s can be safe for the pulp. Further studies must be developed related to the correct positioning of the thermocouples inside the pulp chamber. This was a first step of using diode laser in enamel, and in this study, we concluded that the Opus 10 diode laser shown to be safe for this use, with 1 W power for 10 S. (author)

  18. Nd : YAG surgical laser effects in canine prostate tissue: temperature and damage distribution

    NARCIS (Netherlands)

    van Nimwegen, S. A.; L'Eplattenier, H. F.; Rem, A. I.; van der Lugt, J. J.; Kirpensteijn, J.

    2009-01-01

    An in vitro model was used to predict short-term, laser-induced, thermal damage in canine prostate tissue. Canine prostate tissue samples were equipped with thermocouple probes to measure tissue temperature at 3, 6, 9 and 12 mm depths. The tissue surface was irradiated with a Nd:YAG laser in contact

  19. Quantification of in situ temperature measurements on a PBI-based high temperature PEMFC unit cell

    DEFF Research Database (Denmark)

    Lebæk, Jesper; Ali, Syed Talat; Møller, Per

    2010-01-01

    The temperature is a very important operating parameter for all types of fuel cells. In the present work distributed in situ temperature measurements are presented on a polybenzimidazole based high temperature PEM fuel cell (HT-PEM). A total of 16 T-type thermocouples were embedded on both the an...

  20. Pyrolysis kinetics and combustion of thin wood by an advanced cone caorimetry test method

    Science.gov (United States)

    Mark Dietenberger

    2012-01-01

    Pyrolysis kinetics analysis of extractives, holocellulose, and lignin in the solid redwood over the entire heating regime was possible by specialized cone calorimeter test and new mathematical analysis tools. Added hardware components include: modified sample holder for the thin specimen with tiny thermocouples, the methane ring burner with stainless-steel mesh above...

  1. Rock-mechanical instrumentation of the mine of Stripa

    International Nuclear Information System (INIS)

    Pekkari, R.

    1979-01-01

    The recording of temperature, stress and deformation in a mine makes use of various typer of sensors. A large number of thermocouples, stress gages and deformation sensors have been tested in aggressive environment such as heat and water. Modifications and controls are described along with data acquisition and processing systems. The function of the sensors and applicatory problems are discussed. (G.B.)

  2. Positronium Annihilation Gamma Ray Laser

    Science.gov (United States)

    2009-07-01

    90 deg F using a 75-ohm resistor and the program maintained the temperature at 90 deg F with an inaccuracy of ±1.0 deg. The thermocouple was...pulse train, and propagating the multiple beams from the laser table and enclosure into the positron beam vacuum chamber using piezo - controlled

  3. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    International Nuclear Information System (INIS)

    Cuevas V, G.; Avila N, A.; Calleros M, G.

    2013-10-01

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  4. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G. [Global Nuclear Fuel, Americas, 3901 Castle Hayne Road, Wilmington, North Carolina (United States); Avila N, A.; Calleros M, G., E-mail: Gabriel.Cuevas-Vivas@gnf.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verda, Carretera Veracruz-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  5. Author Details

    African Journals Online (AJOL)

    Ahmad, A. Vol 9, No 6S (2017) - Articles Evaluation of RTD and thermocouple for PID temperature control in distributed control system laboratory. Abstract PDF. ISSN: 1112-9867. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners ...

  6. Author Details

    African Journals Online (AJOL)

    Masrie, M. Vol 9, No 6S (2017) - Articles Evaluation of RTD and thermocouple for PID temperature control in distributed control system laboratory. Abstract PDF. ISSN: 1112-9867. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners ...

  7. Author Details

    African Journals Online (AJOL)

    Saaid, M. F.. Vol 9, No 6S (2017) - Articles Evaluation of RTD and thermocouple for PID temperature control in distributed control system laboratory. Abstract PDF. ISSN: 1112-9867. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners ...

  8. Peltier ac calorimeter

    OpenAIRE

    Jung, D. H.; Moon, I. K.; Jeong, Y. H.

    2001-01-01

    A new ac calorimeter, utilizing the Peltier effect of a thermocouple junction as an ac power source, is described. This Peltier ac calorimeter allows to measure the absolute value of heat capacity of small solid samples with sub-milligrams of mass. The calorimeter can also be used as a dynamic one with a dynamic range of several decades at low frequencies.

  9. Measuring neutron noise induced by travelling air bubbles in a research reactor

    International Nuclear Information System (INIS)

    Por, G.; Horanyi, S.

    1983-05-01

    Travelling air bubble experiments carried out in a research reactor confirm an earlier proposed model. The sink structure could be found experimentally in APSD of neutron signals and was used to determine the bubble velocity. The measurements show that neutron detectors measure the velocity of the travelling bubbles, the thermocouples that of the water flow. (author)

  10. LMFBR transducer performance in SLSF tests P1 and P2

    International Nuclear Information System (INIS)

    English, J.J.; Anderson, T.T.; Kuzay, T.M.; Wilson, R.E.; Pedersen, D.R.; Kaiser, W.C.; Klingler, W.B.

    1977-01-01

    The reliability and problem areas of sodium-immersed thermocouples, pressure transducers and flowmeters are presented for experiments P1 and P2 of the Sodium Loop Safety Facility (SLSF). The SLSF is a doubly-contained sodium loop situated in a core position of the Engineering Test Reactor at the Idaho National Engineering Laboratory

  11. Definition the combined system parameters of photo transducer - thermoelectric transformer

    International Nuclear Information System (INIS)

    Tursunov, M.N.; Dyskin, V.G.; Dadamukhamedov, S.; Yuldoshev, I.A.; Turdiev, B.M.

    2012-01-01

    The construction of the combined device for the conversion of solar radiation, consisting of solar cells and thermocouples is described. The results of measurements carried out the installation, on the basis of which it was concluded that the combined unit increases the conversion efficiency of solar radiation by 5% and such arrangements may be used in countries with very hot climates. (authors)

  12. Fulltext PDF

    Indian Academy of Sciences (India)

    Unknown

    basic scientific understanding and applications in areas such as adsorption and ... This procedure has been adopted in preparing ordered ... also used as precursors to design highly dispersed and ... was measured by a thermocouple spot welded to the crystal. ... of surfaces occurred during the experiments. Annealing of.

  13. Determination of mixing factors for VVER-440 fuel assembly head

    Energy Technology Data Exchange (ETDEWEB)

    Tóth, S., E-mail: toth@reak.bme.hu [Institute of Nuclear Techniques, Budapest University of Technology and Economics, Műegyetem rkp. 9, H-1111 Budapest (Hungary); Aszódi, A. [Institute of Nuclear Techniques, Budapest University of Technology and Economics, Műegyetem rkp. 9, H-1111 Budapest (Hungary)

    2013-11-15

    CFD models have been developed for the heads of the old, the present and the new type VVER-440 fuel assemblies using the experience of a former validation process. With these models temperature distributions are investigated in the heads of some typical assemblies and the in-core thermocouple signals are calculated. The analyses show that the coolant mixing is intensive but not-perfect in the assembly heads. The difference between the thermocouple signal and the cross-sectional average temperature at the measurement level depends on the assembly type. Using the results of these CFD calculations the weight factors of the rod bundle regions for the in-core thermocouple have been determined. With these factors the thermocouple signals are estimated and the results are statistically tested using the registered data of the Hungarian nuclear power plant. This test shows that the deviations between the measured and the calculated temperatures can be significantly decreased and consequently monitoring uncertainties can be reduced with using the weight factors.

  14. A Non-Mercury Thermometer Alternative for Use in Older Melting Point Apparatuses

    Science.gov (United States)

    Ongley, Lois K.; Kern, Clayton S.; Woods, Barry W.

    2008-01-01

    The State of Maine seeks to eliminate most mercury use. This includes removing mercury thermometers from secondary schools and discouraging Hg use in other educational institutions. Alternatives to mercury thermometers in chemical laboratory work include non-mercury thermometers, temperature probes, and thermocouples. In organic chemistry mercury…

  15. Heat generation rates in lithium thionyl chloride cells

    Science.gov (United States)

    Frank, H.

    1982-03-01

    An empirical equation that is useful for good first approximation in thermal modeling is presented. Indications and measurements of electrochemical heat effects were investigated. The particular cells of interest are of the D size, with spiral wound configuration and were instrumented with a thermocouple. It is found that cathode limited cells can explode on reversal at moderate temperatures.

  16. Comparison of CFD Predictions with Shuttle Global Flight Thermal Imagery and Discrete Surface Measurements

    Science.gov (United States)

    Wood, William A.; Kleb, William L.; Tang, chun Y.; Palmer, Grant E.; Hyatt, Andrew J.; Wise, Adam J.; McCloud, Peter L.

    2010-01-01

    Surface temperature measurements from the STS-119 boundary-layer transition experiment on the space shuttle orbiter Discovery provide a rare opportunity to assess turbulent CFD models at hypersonic flight conditions. This flight data was acquired by on-board thermocouples and by infrared images taken off-board by the Hypersonic Thermodynamic Infrared Measurements (HYTHIRM) team, and is suitable for hypersonic CFD turbulence assessment between Mach 6 and 14. The primary assessment is for the Baldwin-Lomax and Cebeci-Smith algebraic turbulence models in the DPLR and LAURA CFD codes, respectively. A secondary assessment is made of the Shear-Stress Transport (SST) two-equation turbulence model in the DPLR code. Based upon surface temperature comparisons at eleven thermocouple locations, the algebraic-model turbulent CFD results average 4% lower than the measurements for Mach numbers less than 11. For Mach numbers greater than 11, the algebraic-model turbulent CFD results average 5% higher than the three available thermocouple measurements. Surface temperature predictions from the two SST cases were consistently 3 4% higher than the algebraic-model results. The thermocouple temperatures exhibit a change in trend with Mach number at about Mach 11; this trend is not reflected in the CFD results. Because the temperature trends from the turbulent CFD simulations and the flight data diverge above Mach 11, extrapolation of the turbulent CFD accuracy to higher Mach numbers is not recommended.

  17. Mixing Hot and Cold Water Streams at a T-Junction

    Science.gov (United States)

    Sharp, David; Zhang, Mingqian; Xu, Zhenghe; Ryan, Jim; Wanke, Sieghard; Afacan, Artin

    2008-01-01

    A simple mixing of a hot- and cold-water stream at a T-junction was investigated. The main objective was to use mass and energy balance equations to predict mass low rates and the temperature of the mixed stream after the T-junction, and then compare these with the measured values. Furthermore, the thermocouple location after the T-junction and…

  18. Experimental determination of the fluid velocity by spectral analysis of temperature fluctuations

    International Nuclear Information System (INIS)

    Foucrier, M.J.; Faya, A.J.G.

    1988-12-01

    Local velocities of turbulent closed channel flow were measured applying the noise analysis technique to signals coming from two sensors separated by a know distance. Good agreement was found when comparing experimental data to more accurate measurements. Ranges of Reynolds number and thermocouple spacial separation are recommended. (author) [pt

  19. MM98.43 Experimental determination of the heat transfer coefficient Under dynamic process conditions in backward can extrusion

    DEFF Research Database (Denmark)

    Henningsen, Poul; Hattel, Jesper Henri; Wanheim, Tarras

    1998-01-01

    The large deformations in backward can extrusion result in a rise of temperature of more than 200 oC. In the experiments, cans in low carbon steel are formed with a lubrication layer of phosphate soap. The temperature is measured by thermocouples in the die insert and the punch. The die insert...

  20. MM98.04 Measurement of temperature and determination of heat transfer coefficient in backward can extrusion

    DEFF Research Database (Denmark)

    Henningsen, Poul; Hattel, Jesper Henri; Wanheim, Tarras

    1998-01-01

    Temperature is measured during backward can extrusion of steel. The process is characterised by large deformations and very high surface pressure. In the experiments, a can in low carbon steel with a lubrication layer of phosphate soap is formed. The temperature is measured by thermocouples...

  1. MM98.34 Experimental Measurements of Die temperatures and determination of heat transfer coefficient in backward can extrusion

    DEFF Research Database (Denmark)

    Henningsen, Poul; Hattel, Jesper Henri; Wanheim, Tarras

    1998-01-01

    The large deformations in backward can extrusion result in a rise of temperature of more than 200 degrees Centigrade. In the experiments cans in low carbon steel are formed, with a lubrication layer of phosphate soap. The temperature is measured by thermocouples in the die insert and the punch...

  2. CHEMICAL STRUCTURES AND THEORETICAL MODELS OF ...

    African Journals Online (AJOL)

    Preferred Customer

    structure of the flames was computed by a simulation code with three ... When all intermediate species were eluted from the Porapak column, the molecular sieve ... This compression greatly enhances the detection limit which .... reduced, to reproduce the sampling conditions, a marked reduction in the thermocouple signal.

  3. Temperature measurement in the liquid helium range at pressure

    International Nuclear Information System (INIS)

    Itskevich, E.S.; Krajdenov, V.F.

    1978-01-01

    The use of bronze and germanium resistance thermometers and the use of a (Au + 0.07 % Fe)-Cu thermocouple for temperature measurements from 1.5 to 4.2 K in the hydrostatic compression of up to 10 kbar are considered. To this aim, the thermometer resistance as a function of temperature and pressure is measured. It is revealed that pressure does not change the thermometric response of the bronze resistance thermometer but only shifts it to the region of lower temperatures. The identical investigations of the germanium resistance thermometer shows that strong temperature dependence and the shift of its thermometric response under the influence of pressure make the use of germanium resistance thermometers in high-pressure chambers very inconvenient. The results of the analysis of the (Au + 0.07 % Fe) - Cu thermocouple shows that with a 2 per cent accuracy the thermocouple Seebeck coefficient does not depend on pressure. It permits to use this thermocouple for temperature measurements at high pressures

  4. Process for constructing a gamma thermometer

    International Nuclear Information System (INIS)

    Barbet, M.J.P.; Cohen, B.S.; Robillard, M.

    1982-01-01

    A process is described for constructing a gamma thermometer having a substance absorbing the radiation and a set of thermocouples for measuring the local power in a fuel assembly of a nuclear reactor. A claim is particularly made for the preparation of the tube containing it and for its filling with an inert gas [fr

  5. TIle development of thermoregulation in Rhabdomys pumilio ...

    African Journals Online (AJOL)

    gically precocial animal. A fine white pelage is present at birth, and four dorsal stripes are ... animals less than five days old, using a fme copper-con- stantan thermocouple probe inserted 1,0-1,2 cm; the probe . .... coincides with the species' lack of nocturnal activity. (Christian 1977). Acknowledgements. I thank Dr R.W. Hill, ...

  6. Application of Advanced Material for Turbomachinery and Rocket Propulsion

    Science.gov (United States)

    1988-10-01

    de fatigue oligocyclique sous charges nominales a 6t6 r~alisi avec succ~s. L’instrumentation en jauges de contrainte a confirm6 lea niveaux de...thermocouples, peintures thermosensibles et jauges de contraintes de fagon A mieux 6valuer leur comportement dans l’environnement du moteur. Aucune anomalie n’s

  7. Developing wireless sensor networks for monitoring crop canopy temperature using a moving sprinkler system as a platform

    Science.gov (United States)

    The objectives of this study were to characterize wireless sensor nodes that we developed in terms of power consumption and functionality, and compare the performance of mesh and non-mesh wireless sensor networks (WSNs) comprised mainly of infrared thermometer thermocouples located on a center pivot...

  8. Temperature measurement during solidification of thin wall ductile cast iron. Part 2: Numerical simulations

    DEFF Research Database (Denmark)

    Pedersen, Karl Martin; Tiedje, Niels Skat

    2008-01-01

    Temperature measurements in castings are carried out with thermocouples (TC’s), which are inserted in the melt. The TC influence solidification of the casting, especially in thin wall castings where the heat content of the melt is small compared to the cooling power of the TC. A numerical analysi...

  9. Pyrolysis kinetics and combustion of thin wood using advanced cone calorimetry test method

    Science.gov (United States)

    Mark A. Dietenberger

    2011-01-01

    Mechanistic pyrolysis kinetics analysis of extractives, holocellulose, and lignin in solid wood over entire heating regime was possible using specialized cone calorimeter test and new mathematical analysis tools. Added hardware components include: modified sample holder for thin specimen with tiny thermocouples, methane ring burner with stainless steel mesh above cone...

  10. Raman study on single-walled carbon nanotubes with different laser ...

    Indian Academy of Sciences (India)

    TECS

    type (Ni–Cr and Ni–Al) thermocouple to fix constant tempe- rature zone inside the reactor. ..... Shirolshi T, Sawada T, Hosono A and Nakata N 2003 Technical. Digest of IVMC. Tan P, Deng Y and Zhao Q 1998 Phys. Rev. B58 5435. Thomsen C ...

  11. A miniature inductive temperature sensor to monitor temperature noise in the coolant of an LMFBR

    International Nuclear Information System (INIS)

    Dean, S.A.; Sandham, C.W.

    1980-01-01

    A description is given of the design and performance of miniature inductive sensors developed to monitor fast temperature fluctuations in the sodium coolant above the core of a LMFBR. These instruments, designed to be installed within existing thermocouple containment thimbles, also provide a steady-state temperature indication for reactor control purposes. (author)

  12. Evaluation of temperature variation in pulp chamber after high power diode laser irradiation ({lambda}=830 nm) on dental enamel: 'in vitro' study; Avaliacao da variacao da temperatura na camara pulpar apos a irradiacao de diodo laser de alta potencia de 830 nanometros em esmalte dental: estudo 'in vitro'

    Energy Technology Data Exchange (ETDEWEB)

    Macri, Rodrigo Teixeira

    2001-07-01

    The aim of this study was to observe the variation of temperature in the pulp chamber caused by irradiation of a commercial diode laser operating in continuous wave with wavelength 830 nm over the dental enamel. In the first part of this study, two types of tooth models were tested: 3,5 mm slice and whole tooth. In the second part, we irradiated the buccal si de of the enamel in 2 primary lower incisors from cattle with Opus 10 diode laser for 10 s with power levels of 1 W and 2 W, always using an absorber. Two thermocouples were used. The first one was inserted in the dentin wall closest to the irradiation site, while the second was inserted in the middle of the pulp chamber. It was observed that the thermocouples registered different temperatures. Always, the dentin thermocouple registered higher temperatures. Considering the dentin records, the irradiation of 1 W for 10 s can be safe for the pulp. Further studies must be developed related to the correct positioning of the thermocouples inside the pulp chamber. This was a first step of using diode laser in enamel, and in this study, we concluded that the Opus 10 diode laser shown to be safe for this use, with 1 W power for 10 S. (author)

  13. Refractory thermowell for continuous high temperature measurement of molten metal

    International Nuclear Information System (INIS)

    Thiesen, T.J.

    1992-01-01

    This patent describes a vessel for handling molten metal having an interior refractory lining, apparatus for continuous high temperature measurement of the molten metal. It comprises a thermowell; the thermowell containing a multiplicity of thermocouples; leads being coupled to a means for continuously indicating the temperature of the molten metal in the vessel

  14. Method of detecting coolant leakages from the pipeways in FBR type reactors

    International Nuclear Information System (INIS)

    Sonoda, Yukio; Tamaoki, Tetsuo

    1986-01-01

    Purpose: To detect coolant leakage in the incore pipeways of loop type FBR type reactors in the initial stage at high sensitivity. Constitution: Temperature of the coolants sealed between incore pipeways and the buffle surrounding them is measured by thermocouples and coolant leakage is detected due to fluctuating components. A well-insertion type in which electrode is sealed with argon is used as the thermo-couples. Signals from the thermocouples are once amplified, removed with DC components and then only the fluctuating components are outputted. The fluctuating components are digitalized, passed through an adaptive digital filter and the RMS value as the difference between the output signal and the thermocouple signal is calculated. The calculated value is compared with a threshold value in a comparative calculator. If it exceeds the threshold value, it is judged as abnormal to display an alarm on an alarm display. In this way, the coolant leakage for the pipeways in the FBR type reactor can be detected on real time and at high sensitivity. (Kamimura, M.)

  15. A study on structural stability of bismuth titanate with lanthanum ...

    Indian Academy of Sciences (India)

    2017-05-13

    May 13, 2017 ... such as high leakage current and domain pinning, which leads to small remanent ... (La(NO3)3 · 6H2O) were dissolved in distilled water for 2 h with constant ... a thermocouple (K-type, maximum detection at 1200. ◦. C). The.

  16. Application of the method of thermo-power in diagnosing fatigue strength and intergrain corrosion

    Directory of Open Access Journals (Sweden)

    Prokhorenko V.J.

    2009-04-01

    Full Text Available In area of flat defect, predefined a gradient tireless - corrosive tensions, a double electric layer, conditioned the spatial redistribution of electronic closeness, is formed. It shows up a local rejection mikro-thermo-power at use of heating edge of tungsten thermocouple. Test approbation of method is conducted on the deformed chromel.

  17. Stable atmospheric boundary-layer experiment in Spain (SABLES 98): A report

    DEFF Research Database (Denmark)

    Cuxart, J.; Yague, C.; Morales, G.

    2000-01-01

    boundary layer (SBL). Instrumentation deployed on two meteorological masts (of heights 10 m and 100 m) included five sonic anemometers, 15 thermocouples, five cup anemometers and three propeller anemometers, humidity sensors and radiometers. A Sensitron mini-sodar and a tethered balloon were also operated...

  18. Optimal operation of thermoelectric cooler driven by solar thermoelectric generator

    International Nuclear Information System (INIS)

    Khattab, N.M.; El Shenawy, E.T.

    2006-01-01

    The possibility of using a solar thermoelectric generator (TEG) to drive a small thermoelectric cooler (TEC) is studied in the present work. The study includes the theory of both the TEG and the TEC, giving special consideration to determination of the number of TEG modules required to power the TEC to achieve the best performance of the TEG-TEC system all year round. Commercially available thermoelectric modules (TE) are used in the system. The TEG contains 49 thermocouples and the TEC contains 127 thermocouples. A simple arrangement of plane reflectors that are designed to receive maximum solar energy during noon time is used to heat the TEG. Performance tests are conducted to determine both the physical properties and the performance curves of the available TE modules. Also, empirical relations describing the performance of the TEG and TEC modules have been established. These relations are used to develop a mathematical model simulating the TEG-TEC system to predict its performance all year round under the actual climatic conditions of Cairo, Egypt (30 deg. N latitude). The model results are used to determine the number of TEG modules required to drive a single TEC module at maximum cooling capacity. The results show that five thermocouples of the TEG can drive one thermocouple of the TEC, which coincides with the previous theory of the TEG-TEC. This means that 10 of the used TEG modules are required to power the used TEC at optimum performance most times of the year

  19. Center for Research on Infrared Detectors (CENTROID)

    Science.gov (United States)

    2006-09-30

    of growth, x is also monitored in situ by SE, and Tis measured by a thermocouple, a pyrometer and indirectly by the heating power and is calibrated...Polar optical, acoustic , and inter-valley phonon scattering are included, as wells as scattering from the quantum dots. The simulation includes

  20. Solid Layer Thermal-conductivity Measurement Techniques

    Science.gov (United States)

    1994-03-01

    deposited on the sample, and the absorption of laser radiation. Temperature-measurement tools include thermocouples, infrared (IR) pyrometers , and...A, Nishimura H, and Sawada T (1990), Laser-Induc~d Surface Acoustic Waves and Photothc:rmal Surfitce Gratings Generated by Crossing Two Pulsed