WorldWideScience

Sample records for self-report instrument designed

  1. Protocol for the design of an instrument to measure preadolescent children's self-report of covert aggression and bullying

    Science.gov (United States)

    Nelson, Helen Jean; Kendall, Garth Edward; Burns, Sharyn; Schonert-Reichl, Kimberly

    2015-01-01

    Introduction Covert bullying in schools is associated with a range of academic, social, emotional and physical health problems. Much research has focused on bullying, but there remains a gap in understanding about covert aggression and how to most accurately and reliably measure children's own reports of this behaviour. This paper reviews relevant literature and outlines a research project that aims to develop a self-report instrument that effectively measures covert aggression and bullying. It is anticipated that this research will result in a standardised instrument that is suitable for exploring preadolescent children's experiences of covert aggressive behaviour. The data collected by the instrument will enhance health and education professionals understanding of covert bullying behaviours and will inform the design and evaluation of interventions. Methods and analysis Relational developmental systems theory will guide the design of an online self-report instrument. The first phase of the project will include a critical review of the research literature, focus groups with children aged 8–12 years (grades 4–6) in Perth, Western Australia, and expert review. The instrument will be explored for content and face validity prior to the assessment of convergent and discriminant validity, internal consistency and test-retest reliability. Ethics and dissemination The study has been approved by the Curtin University of Human Research Ethics Committee (RDHS-38-15) and by the Executive Principal of the participating school. PMID:26553834

  2. Design, implementation, and demographic differences of HEAL: a self-report health care leadership instrument.

    Science.gov (United States)

    Murphy, Kelly R; McManigle, John E; Wildman-Tobriner, Benjamin M; Little Jones, Amy; Dekker, Travis J; Little, Barrett A; Doty, Joseph P; Taylor, Dean C

    2016-01-01

    The medical community has recognized the importance of leadership skills among its members. While numerous leadership assessment tools exist at present, few are specifically tailored to the unique health care environment. The study team designed a 24-item survey (Healthcare Evaluation & Assessment of Leadership [HEAL]) to measure leadership competency based on the core competencies and core principles of the Duke Healthcare Leadership Model. A novel digital platform was created for use on handheld devices to facilitate its distribution and completion. This pilot phase involved 126 health care professionals self-assessing their leadership abilities. The study aimed to determine both the content validity of the survey and the feasibility of its implementation and use. The digital platform for survey implementation was easy to complete, and there were no technical problems with survey use or data collection. With regard to reliability, initial survey results revealed that each core leadership tenet met or exceeded the reliability cutoff of 0.7. In self-assessment of leadership, women scored themselves higher than men in questions related to patient centeredness ( P =0.016). When stratified by age, younger providers rated themselves lower with regard to emotional intelligence and integrity. There were no differences in self-assessment when stratified by medical specialty. While only a pilot study, initial data suggest that HEAL is a reliable and easy-to-administer survey for health care leadership assessment. Differences in responses by sex and age with respect to patient centeredness, integrity, and emotional intelligence raise questions about how providers view themselves amid complex medical teams. As the survey is refined and further administered, HEAL will be used not only as a self-assessment tool but also in "360" evaluation formats.

  3. Design, implementation, and demographic differences of HEAL: a self-report health care leadership instrument

    Directory of Open Access Journals (Sweden)

    Murphy KR

    2016-10-01

    Full Text Available Kelly R Murphy, John E McManigle, Benjamin M Wildman-Tobriner, Amy Little Jones, Travis J Dekker, Barrett A Little, Joseph P Doty, Dean C Taylor Duke Healthcare Leadership Program, Duke University School of Medicine, Durham, NC, USA Abstract: The medical community has recognized the importance of leadership skills among its members. While numerous leadership assessment tools exist at present, few are specifically tailored to the unique health care environment. The study team designed a 24-item survey (Healthcare Evaluation & Assessment of Leadership [HEAL] to measure leadership competency based on the core competencies and core principles of the Duke Healthcare Leadership Model. A novel digital platform was created for use on handheld devices to facilitate its distribution and completion. This pilot phase involved 126 health care professionals self-assessing their leadership abilities. The study aimed to determine both the content validity of the survey and the feasibility of its implementation and use. The digital platform for survey implementation was easy to complete, and there were no technical problems with survey use or data collection. With regard to reliability, initial survey results revealed that each core leadership tenet met or exceeded the reliability cutoff of 0.7. In self-assessment of leadership, women scored themselves higher than men in questions related to patient centeredness (P=0.016. When stratified by age, younger providers rated themselves lower with regard to emotional intelligence and integrity. There were no differences in self-assessment when stratified by medical specialty. While only a pilot study, initial data suggest that HEAL is a reliable and easy-to-administer survey for health care leadership assessment. Differences in responses by sex and age with respect to patient centeredness, integrity, and emotional intelligence raise questions about how providers view themselves amid complex medical teams. As the

  4. Designing hunting regulation under population uncertainty and self-reporting

    DEFF Research Database (Denmark)

    Jensen, Frank; Jacobsen, Jette Bredahl; Thorsen, Bo Jellesmark

    2016-01-01

    A number of methods exist for estimating the size of animal populations. All methods generate an uncertain estimate of population size, and have different properties, which can be taken into account when designing regulation. We consider hunting regulation when the population size is uncertain...... and when the self-reported bag is used to estimate the population size. The properties of a population tax and a tax on self-reported bag are analyzed and we begin by considering a baseline situation with full certainty and no use of self-reporting for population size estimation. Here individual hunters...... self-report a bag on zero and a population tax alone can secure an optimum. Next we show that when facing uncertain population size, a risk-averse hunter will self-report part of the bag to reduce the uncertain population tax payment, making both tax instruments necessary for reaching an optimum...

  5. Development of a new occupational balance-questionnaire: incorporating the perspectives of patients and healthy people in the design of a self-reported occupational balance outcome instrument.

    Science.gov (United States)

    Dür, Mona; Steiner, Günter; Fialka-Moser, Veronika; Kautzky-Willer, Alexandra; Dejaco, Clemens; Prodinger, Birgit; Stoffer, Michaela Alexandra; Binder, Alexa; Smolen, Josef; Stamm, Tanja Alexandra

    2014-04-05

    Self-reported outcome instruments in health research have become increasingly important over the last decades. Occupational therapy interventions often focus on occupational balance. However, instruments to measure occupational balance are scarce. The aim of the study was therefore to develop a generic self-reported outcome instrument to assess occupational balance based on the experiences of patients and healthy people including an examination of its psychometric properties. We conducted a qualitative analysis of the life stories of 90 people with and without chronic autoimmune diseases to identify components of occupational balance. Based on these components, the Occupational Balance-Questionnaire (OB-Quest) was developed. Construct validity and internal consistency of the OB-Quest were examined in quantitative data. We used Rasch analyses to determine overall fit of the items to the Rasch model, person separation index and potential differential item functioning. Dimensionality testing was conducted by the use of t-tests and Cronbach's alpha. The following components emerged from the qualitative analyses: challenging and relaxing activities, activities with acknowledgement by the individual and by the sociocultural context, impact of health condition on activities, involvement in stressful activities and fewer stressing activities, rest and sleep, variety of activities, adaptation of activities according to changed living conditions and activities intended to care for oneself and for others. Based on these, the seven items of the questionnaire (OB-Quest) were developed. 251 people (132 with rheumatoid arthritis, 43 with systematic lupus erythematous and 76 healthy) filled in the OB-Quest. Dimensionality testing indicated multidimensionality of the questionnaire (t = 0.58, and 1.66 after item reduction, non-significant). The item on the component rest and sleep showed differential item functioning (health condition and age). Person separation index was 0

  6. Continence following radical retropubic prostatectomy using self-reporting instruments.

    Science.gov (United States)

    Lepor, Herbert; Kaci, Ledia; Xue, Xiaonan

    2004-03-01

    We performed a global self-assessment of continence following radical retropubic prostatectomy (RRP) and determined how this global self-assessment of continence correlates with commonly used definitions of continence. Between October 2000 and February 2002 all men who underwent RRP were encouraged to complete the University of California-Los Angeles Prostate Cancer Index 3, 6, 12 and 24 months postoperatively. Beginning October 2002 a single question capturing the patient global self-assessment of continence status was added to the postoperative continence assessment. The study design was cross-sectional since only continence surveys submitted between October 2002 through February 2003 were evaluated. Sensitivity, specificity and kappa coefficient was determined for the relationship between the patient global assessment of continence vs the definition of continence based on pad requirement, problem due to incontinence and frequency of incontinence. Continence progressively improved 3 to 24 months following RRP for all continence outcomes. At 24 months following RRP 97.1% of men considered themselves continent, while 97.1%, 94.1% and 97.1% were considered continent using continence definitions, including the requirement of no or 1 pad in a 24-hour interval, no or slight bother due to incontinence and total control or occasional dribbling, respectively. Our 3 definitions of continence derived from responses to the University of California-Los Angeles Prostate Cancer Index had excellent agreement with patient global self-assessment of continence (kappa coefficients between 0.76 and 0.83). The majority of men achieve continence without invasive intervention following RRP. Final continence status should be ascertained at 24 months. The patient global assessment of continence provides face validity for other definitions of continence based on responses to validated self-administered questionnaires.

  7. An assessment of self-reported physical activity instruments in young people for population surveillance: Project ALPHA

    Directory of Open Access Journals (Sweden)

    Pearson Natalie

    2011-01-01

    Full Text Available Abstract Background The assessment of physical activity is an essential part of understanding patterns and influences of behaviour, designing interventions, and undertaking population surveillance and monitoring, but it is particularly problematic when using self-report instruments with young people. This study reviewed available self-report physical activity instruments developed for use with children and adolescents to assess their suitability and feasibility for use in population surveillance systems, particularly in Europe. Methods Systematic searches and review, supplemented by expert panel assessment. Results Papers (n = 437 were assessed as potentially relevant; 89 physical activity measures were identified with 20 activity-based measures receiving detailed assessment. Three received support from the majority of the expert group: Physical Activity Questionnaire for Children/Adolescents (PAQ-C/PAQ-A, Youth Risk Behaviour Surveillance Survey (YRBS, and the Teen Health Survey. Conclusions Population surveillance of youth physical activity is strongly recommended and those involved in developing and undertaking this task should consider the three identified shortlisted instruments and evaluate their appropriateness for application within their national context. Further development and testing of measures suitable for population surveillance with young people is required.

  8. Measuring social science concepts in pharmacy education research: From definition to item analysis of self-report instruments.

    Science.gov (United States)

    Cor, M Ken

    Interpreting results from quantitative research can be difficult when measures of concepts are constructed poorly, something that can limit measurement validity. Social science steps for defining concepts, guidelines for limiting construct-irrelevant variance when writing self-report questions, and techniques for conducting basic item analysis are reviewed to inform the design of instruments to measure social science concepts in pharmacy education research. Based on a review of the literature, four main recommendations emerge: These include: (1) employ a systematic process of conceptualization to derive nominal definitions; (2) write exact and detailed operational definitions for each concept, (3) when creating self-report questionnaires, write statements and select scales to avoid introducing construct-irrelevant variance (CIV); and (4) use basic item analysis results to inform instrument revision. Employing recommendations that emerge from this review will strengthen arguments to support measurement validity which in turn will support the defensibility of study finding interpretations. An example from pharmacy education research is used to contextualize the concepts introduced. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Measuring self-reported health in low-income countries: piloting three instruments in semi-rural Burkina Faso

    Directory of Open Access Journals (Sweden)

    Yulia Blomstedt

    2012-07-01

    Full Text Available Background: National surveys in low-income countries increasingly rely on self-reported measures of health. The ease, speed, and economy of collecting self-reports of health make such collection attractive for rapid appraisals. However, the interpretation of these measures is complicated since different cultures understand and respond to the same question in different ways. Objective: The aim of this pilot study was to develop a culturally sensitive tool to study the self-reported health (SRH of the local adult population in Burkina Faso. Design: The study was carried out in the 2009 rainy season. The sample included 27 men and 25 women aged 18 or older who live in semi-urban Nouna, Burkina Faso. Three culturally adapted instruments were tested: a SRH question, a wooden visual analogue scale (VAS, and a drawn VAS. Respondents were asked to explain their answers to each instrument. The narratives were analyzed with the content analysis technique, and the prevalence of poor SRH was estimated from the quantitative data by stratification for respondent background variables (sex, age, literacy, education, marital status, ethnicity, chronic diseases. The correlation between the instruments was tested with Spearman's correlation test. Results: The SRH question showed a 38.5% prevalence of poor SRH and 44.2% prevalence with both VAS. The correlation between the VAS was 0.89, whereas the correlation between the VAS and the SRH question was 0.60–0.64. Nevertheless, the question used as the basis of each instrument was culturally sensitive and clear to all respondents. Analysis of the narratives shows that respondents clearly differentiated between the various health statuses. Conclusion: In this pilot, we developed and tested a new version of the SRH question that may be more culturally sensitive than its non-adapted equivalents. Additional insight into this population's understanding and reporting of health was also obtained. A larger sample is needed

  10. Pooled results from five validation studies of dietary self-report instruments using recovery biomarkers for potassium and sodium intake

    Science.gov (United States)

    We have pooled data from five large validation studies of dietary self-report instruments that used recovery biomarkers as referents to assess food frequency questionnaires (FFQs) and 24-hour recalls. We reported on total potassium and sodium intakes, their densities, and their ratio. Results were...

  11. Pooled results from 5 validation studies of dietary self-report instruments using recovery biomarkers for energy and protein intake

    Science.gov (United States)

    We pooled data from 5 large validation studies of dietary self-report instruments that used recovery biomarkers as references to clarify the measurement properties of food frequency questionnaires (FFQs) and 24-hour recalls. The studies were conducted in widely differing U.S. adult populations from...

  12. Convergent and Discriminant Validity of Psychopathy Factors Assessed Via Self-Report: A Comparison of Three Instruments

    OpenAIRE

    Benning, Stephen D.; Patrick, Christopher J.; Salekin, Randall T.; Leistico, Anne-Marie R.

    2005-01-01

    Psychopathy has been conceptualized as a personality disorder with distinctive interpersonal-affective and behavioral deviance features. The authors examine correlates of the factors of the Psychopathic Personality Inventory (PPI), Self-Report Psychopathy–II (SRP-II) scale, and Antisocial Process Screening Device (APSD) to understand similarities and differences among the constructs embodied in these instruments. PPI Fearless Dominance and SRP-II Factor 1 were negatively related to most perso...

  13. Achievement Emotions in Technology Enhanced Learning: Development and Validation of Self-Report Instruments in the Italian Context

    Directory of Open Access Journals (Sweden)

    Daniela Raccanello

    2015-02-01

    Full Text Available The increased use of technology within the educational field gives rise to the need for developing valid instruments to measure key constructs associated with performance. We present some self-report instruments developed and/or validated in the Italian context that could be used to assess achievement emotions and correlates, within the theoretical framework of Pekrun’s control-value model. First, we propose some data related to the construction of two instruments developed to assess ten achievement emotions: the Brief Achievement Emotions Questionnaire, BR-AEQ, used with college students, and the Graduated Achievement Emotions Set, GR-AES, used with primary school students. Second, we describe some data concerning the validation within the Italian context of two instruments assessing achievement goals as antecedents of achievement emotions: the Achievement Goal Questionnaire-Revised, AGQ-R, and its more recent version based on the 3 X 2 achievement goal model.

  14. Quality appraisal of generic self-reported instruments measuring health-related productivity changes: a systematic review

    Science.gov (United States)

    2014-01-01

    Background Health impairments can result in disability and changed work productivity imposing considerable costs for the employee, employer and society as a whole. A large number of instruments exist to measure health-related productivity changes; however their methodological quality remains unclear. This systematic review critically appraised the measurement properties in generic self-reported instruments that measure health-related productivity changes to recommend appropriate instruments for use in occupational and economic health practice. Methods PubMed, PsycINFO, Econlit and Embase were systematically searched for studies whereof: (i) instruments measured health-related productivity changes; (ii) the aim was to evaluate instrument measurement properties; (iii) instruments were generic; (iv) ratings were self-reported; (v) full-texts were available. Next, methodological quality appraisal was based on COSMIN elements: (i) internal consistency; (ii) reliability; (iii) measurement error; (iv) content validity; (v) structural validity; (vi) hypotheses testing; (vii) cross-cultural validity; (viii) criterion validity; and (ix) responsiveness. Recommendations are based on evidence syntheses. Results This review included 25 articles assessing the reliability, validity and responsiveness of 15 different generic self-reported instruments measuring health-related productivity changes. Most studies evaluated criterion validity, none evaluated cross-cultural validity and information on measurement error is lacking. The Work Limitation Questionnaire (WLQ) was most frequently evaluated with moderate respectively strong positive evidence for content and structural validity and negative evidence for reliability, hypothesis testing and responsiveness. Less frequently evaluated, the Stanford Presenteeism Scale (SPS) showed strong positive evidence for internal consistency and structural validity, and moderate positive evidence for hypotheses testing and criterion validity. The

  15. Systematic review of measurement properties of self-reported instruments for evaluating self-care in adults.

    Science.gov (United States)

    Matarese, Maria; Lommi, Marzia; De Marinis, Maria Grazia

    2017-06-01

    The aims of this study were as follows: to identify instruments developed to assess self-care in healthy adults; to determine the theory on which they were based; their validity and reliability properties and to synthesize the evidence on their measurement properties. Many instruments have been developed to assess self-care in many different populations and conditions. Clinicians and researchers should select the most appropriate self-care instrument based on the knowledge of their measurement properties. Systematic review of measurement instruments according to the protocol recommended by the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. PubMed, Embase, PsycINFO, Scopus and CINAHL databases were searched from inception to December 2015. Studies testing measurement properties of self-report instruments assessing self-care in healthy adults, published in the English language and in peer review journals were selected. Two reviewers independently appraised the methodological quality of the studies with the COSMIN checklist and the quality of results using specific quality criteria. Twenty-six articles were included in the review testing the measurement properties of nine instruments. Seven instruments were based on Orem's Self-care theory. Not all the measurement properties were evaluated for the identified instruments. No self-care instrument showed strong evidence supporting the evaluated measurement properties. Despite the development of several instruments to assess self-care in the adult population, no instrument can be fully recommended to clinical nurses and researchers. Further studies of high methodological quality are needed to confirm the measurement properties of these instruments. © 2016 John Wiley & Sons Ltd.

  16. Website design: technical, social and medical issues for self-reporting by elderly patients.

    Science.gov (United States)

    Taylor, Mark J; Stables, Rod; Matata, Bashir; Lisboa, Paulo J G; Laws, Andy; Almond, Peter

    2014-06-01

    There is growing interest in the use of the Internet for interacting with patients, both in terms of healthcare information provision and information gathering. In this article, we examine the issues in designing healthcare websites for elderly users. In particular, this article uses a year-long case study of the development of a web-based system for self-reporting of symptoms and quality of life with a view to examine the issues relating to website design for elderly users. The issues identified included the technical, social and medical aspects of website design for elderly users. The web-based system developed was based on the European Quality of Life 5-Dimensions health-status questionnaire, a commonly used tool for patient self-reporting of quality of life, and the more specific coronary revascularisation outcome questionnaire. Currently, self-reporting is generally administered in the form of paper-based questionnaires to be completed in the outpatient clinic or at home. There are a variety of issues relating to elderly users, which imply that websites for elderly patients may involve different design considerations to other types of websites.

  17. Application of a New Statistical Model for Measurement Error to the Evaluation of Dietary Self-report Instruments.

    Science.gov (United States)

    Freedman, Laurence S; Midthune, Douglas; Carroll, Raymond J; Commins, John M; Arab, Lenore; Baer, David J; Moler, James E; Moshfegh, Alanna J; Neuhouser, Marian L; Prentice, Ross L; Rhodes, Donna; Spiegelman, Donna; Subar, Amy F; Tinker, Lesley F; Willett, Walter; Kipnis, Victor

    2015-11-01

    Most statistical methods that adjust analyses for dietary measurement error treat an individual's usual intake as a fixed quantity. However, usual intake, if defined as average intake over a few months, varies over time. We describe a model that accounts for such variation and for the proximity of biomarker measurements to self-reports within the framework of a meta-analysis, and apply it to the analysis of data on energy, protein, potassium, and sodium from a set of five large validation studies of dietary self-report instruments using recovery biomarkers as reference instruments. We show that this time-varying usual intake model fits the data better than the fixed usual intake assumption. Using this model, we estimated attenuation factors and correlations with true longer-term usual intake for single and multiple 24-hour dietary recalls (24HRs) and food frequency questionnaires (FFQs) and compared them with those obtained under the "fixed" method. Compared with the fixed method, the estimates using the time-varying model showed slightly larger values of the attenuation factor and correlation coefficient for FFQs and smaller values for 24HRs. In some cases, the difference between the fixed method estimate and the new estimate for multiple 24HRs was substantial. With the new method, while four 24HRs had higher estimated correlations with truth than a single FFQ for absolute intakes of protein, potassium, and sodium, for densities the correlations were approximately equal. Accounting for the time element in dietary validation is potentially important, and points toward the need for longer-term validation studies.

  18. Posttraumatic growth measures: translation and adaptation of three self-report instruments to Brazilian Portuguese

    Directory of Open Access Journals (Sweden)

    Thiago Loreto Garcia da Silva

    2016-06-01

    Full Text Available Abstract Background Posttraumatic growth is one of the most commonly used concepts to evaluate positive changes after trauma. The principal scales used internationally to evaluate this phenomenon have not yet a Brazilian Portuguese version. Objectives This study aimed to translate and adapt to the Brazilian context the Posttraumatic Growth Inventory (PTGI, the Core Beliefs Inventory (CBI, and the Event Related Rumination Inventory (ERRI. Methods The procedures included translation, back translation, expert committee’s evaluation, and pilot testing in the target population. Results All items of all three instruments had a good content validity index after evaluation by four experts and three reformulations. The back translation of the final version also demonstrated that all Brazilian Portuguese versions convey the same meaning as the original English version. The final version was pilot tested with 30 undergraduate students, and all the items were above the cut-off point. Discussion This study was able to produce Brazilian versions of the PTGI, CBI, and ERRI. Further studies are underway to determine the reliability, factorial validity, and convergent validity of the subscales of the instruments.

  19. Testing and development of an instrument for self-report of participation and related environmental factors - Your Ideas about Participation and Environment (YIPE) among adults with brain injury.

    Science.gov (United States)

    Hawley, Rachael; Madden, Rosamond H; Brentnall, Jennie; Serratore, Deborah; Grant, Samantha; Luft, Inbal; Bundy, Anita

    2016-11-01

    To examine the usability of the self-report instrument, Your Ideas about Participation and Environment (YIPE), among adults with a brain injury by exploring the value and acceptability of the instrument. A qualitative descriptive research design was used for the purpose of testing and developing the YIPE for use among adults with a brain injury. The study involved administering the YIPE followed by in-depth interviewing about the experience of taking the instrument with seven adults with a brain injury, recruited through a community-based support service organization. A descriptive thematic approach was used to analyse the content of the interview data, categorize common ideas and identify areas for improvement within the instrument. Participants were generally positive about the importance of the participation and environment topics and willing to engage in self report. The YIPE (2012), resulting from changes made to the language and structure, was found to be more useable, valued and accepted by these participants than the previous version, YIPE (2011). The YIPE was found to be a useful tool among study participants. The YIPE topics were found to have importance and relevance when considering participants' satisfaction with areas of life and aspects of environment requiring change. More development of the tool is required in terms of the wording, format and method of administration to improve the overall usability of the instrument. Implications for Rehabilitation The preliminary results from this small sample study illustrated that people with brain injury were able to use an International Classification of Functioning, Disability and Health-based tool, and confirmed the importance of considering both participation and the environment together. People with cognitive impairments associated with brain injury reported on areas of everyday life where they were satisfied or dissatisfied. They related their satisfaction to environmental factors that were facilitators

  20. Measuring children's self-reported sport participation, risk perception and injury history: development and validation of a survey instrument.

    Science.gov (United States)

    Siesmaa, Emma J; Blitvich, Jennifer D; White, Peta E; Finch, Caroline F

    2011-01-01

    Despite the health benefits associated with children's sport participation, the occurrence of injury in this context is common. The extent to which sport injuries impact children's ongoing involvement in sport is largely unknown. Surveys have been shown to be useful for collecting children's injury and sport participation data; however, there are currently no published instruments which investigate the impact of injury on children's sport participation. This study describes the processes undertaken to assess the validity of two survey instruments for collecting self-reported information about child cricket and netball related participation, injury history and injury risk perceptions, as well as the reliability of the cricket-specific version. Face and content validity were assessed through expert feedback from primary and secondary level teachers and from representatives of peak sporting bodies for cricket and netball. Test-retest reliability was measured using a sample of 59 child cricketers who completed the survey on two occasions, 3-4 weeks apart. Based on expert feedback relating to face and content validity, modification and/or deletion of some survey items was undertaken. Survey items with low test-retest reliability (κ≤0.40) were modified or deleted, items with moderate reliability (κ=0.41-0.60) were modified slightly and items with higher reliability (κ≥0.61) were retained, with some undergoing minor modifications. This is the first survey of its kind which has been successfully administered to cricketers aged 10-16 years to collect information about injury risk perceptions and intentions for continued sport participation. Implications for its generalisation to other child sport participants are discussed. Copyright © 2010 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  1. Industrial instrumentation principles and design

    CERN Document Server

    Padmanabhan, Tattamangalam R

    2000-01-01

    Pneumatic, hydraulic and allied instrumentation schemes have given way to electronic schemes in recent years thanks to the rapid strides in electronics and allied areas. Principles, design and applications of such state-of-the-art instrumentation schemes form the subject matter of this book. Through representative examples, the basic building blocks of instrumentation schemes are identified and each of these building blocks discussed in terms of its design and interface characteristics. The common generic schemes synthesized with such building blocks are dealt with subsequently. This forms the scope of Part I. The focus in Part II is on application. Displacement and allied instrumentation, force and allied instrumentation and process instrumentation in terms of temperature, flow, pressure level and other common process variables are dealt with separately and exhaustively. Despite the diversity in the sensor principles and characteristics and the variety in the applications and their environments, it is possib...

  2. Evaluation of the measurement properties of self-reported health-related work-functioning instruments among workers with common mental disorders.

    Science.gov (United States)

    Abma, Femke I; van der Klink, Jac J L; Terwee, Caroline B; Amick, Benjamin C; Bültmann, Ute

    2012-01-01

    During the past decade, common mental disorders (CMD) have emerged as a major public and occupational health problem in many countries. Several instruments have been developed to measure the influence of health on functioning at work. To select appropriate instruments for use in occupational health practice and research, the measurement properties (eg, reliability, validity, responsiveness) must be evaluated. The objective of this study is to appraise critically and compare the measurement properties of self-reported health-related work-functioning instruments among workers with CMD. A systematic review was performed searching three electronic databases. Papers were included that: (i) mainly focused on the development and/or evaluation of the measurement properties of a self-reported health-related work-functioning instrument; (ii) were conducted in a CMD population; and (iii) were fulltext original papers. Quality appraisal was performed using the consensus-based standards for the selection of health status measurement instruments (COSMIN) checklist. Five papers evaluating measurement properties of five self-reported health-related work-functioning instruments in CMD populations were included. There is little evidence available for the measurement properties of the identified instruments in this population, mainly due to low methodological quality of the included studies. The available evidence on measurement properties is based on studies of poor-to-fair methodological quality. Information on a number of measurement properties, such as measurement error, content validity, and cross-cultural validity is still lacking. Therefore, no evidence-based decisions and recommendations can be made for the use of health-related work functioning instruments. Studies of high methodological quality are needed to properly assess the existing instruments' measurement properties.

  3. Instrument design and automation

    International Nuclear Information System (INIS)

    Wernlund, R.F.

    1984-01-01

    The ion mobility spectrometer-mass spectrometer (IMS-MS) is described and consists of two separate instruments coupled in tandem: an ion mobility spectrometer coupled to a quadrupole mass spectrometer. The two insturments operate at different pressures in a synergistic manner, supplying both drift time and mass information about ions which are formed at atmospheric pressure in the ion mobility spectrometer tube. Two types of ion intensity signals are presented to the data processor. The IMS produces an analog voltage with major components from dc to 5 KHz. The mass spectrometer signal output resides in the pulse count rate derived from a series of TTL level pulses where each pulse represents the arrival of a single ion. The hardware, software, interfacing capabilities and basic data acquisition program are described in detail

  4. A Measure for Pupils' Inconsistency of Response to a Self-Report Instrument of Attitudes toward School.

    Science.gov (United States)

    Darom, Efraim; Rich, Yisrael

    1983-01-01

    To measure pupils' inconsistency in replying to a self-report questionnaire regarding attitudes toward school, 6,000 elementary and secondary school students participated in a nation-wide project to construct and validate the Israeli Quality of School Life Questionnaire (IQSL). (PN)

  5. Convergent and Discriminant Validity of Psychopathy Factors Assessed via Self-Report: A Comparison of Three Instruments

    Science.gov (United States)

    Benning, Stephen D.; Patrick, Christopher J.; Salekin, Randall T.; Leistico, Anne-Marie R.

    2005-01-01

    Psychopathy has been conceptualized as a personality disorder with distinctive interpersonal-affective and behavioral deviance features. The authors examine correlates of the factors of the Psychopathic Personality Inventory (PPI), Self-Report Psychopathy-II (SRP-II) scale, and Antisocial Process Screening Device (APSD) to understand similarities…

  6. Errors in self-reports of health services use: impact on alzheimer disease clinical trial designs.

    Science.gov (United States)

    Callahan, Christopher M; Tu, Wanzhu; Stump, Timothy E; Clark, Daniel O; Unroe, Kathleen T; Hendrie, Hugh C

    2015-01-01

    Most Alzheimer disease clinical trials that compare the use of health services rely on reports of caregivers. The goal of this study was to assess the accuracy of self-reports among older adults with Alzheimer disease and their caregiver proxy respondents. This issue is particularly relevant to Alzheimer disease clinical trials because inaccuracy can lead both to loss of power and increased bias in study outcomes. We compared respondent accuracy in reporting any use and in reporting the frequency of use with actual utilization data as documented in a comprehensive database. We next simulated the impact of underreporting and overreporting on sample size estimates and treatment effect bias for clinical trials comparing utilization between experimental groups. Respondents self-reports have a poor level of accuracy with κ-values often below 0.5. Respondents tend to underreport use even for rare events such as hospitalizations and nursing home stays. In analyses simulating underreporting and overreporting of varying magnitude, we found that errors in self-reports can increase the required sample size by 15% to 30%. In addition, bias in the reported treatment effect ranged from 3% to 18% due to both underreporting and overreporting errors. Use of self-report data in clinical trials of Alzheimer disease treatments may inflate sample size needs. Even when adequate power is achieved by increasing sample size, reporting errors can result in a biased estimate of the true effect size of the intervention.

  7. Construct Validity of the SF-12v2 for the Homeless Population with Mental Illness: An Instrument to Measure Self-Reported Mental and Physical Health.

    Science.gov (United States)

    Chum, Antony; Skosireva, Anna; Tobon, Juliana; Hwang, Stephen

    2016-01-01

    Self-reported health measures are important indicators used by clinicians and researchers for the evaluation of health interventions, outcome assessment of clinical studies, and identification of health needs to improve resource allocation. However, the application of self-reported health measures relies on developing reliable and valid instruments that are suitable across diverse populations. The main objective of this study is to evaluate the construct validity of the SF-12v.2, an instrument for measuring self-rated physical and mental health, for homeless adults with mental illness. Various interventions have been aimed at improving the health of homeless people with mental illness, and the development of valid instruments to evaluate these interventions is imperative. We measured self-rated mental and physical health from a quota sample of 575 homeless people with mental illness using the SF-12v2, EQ-5D, Colorado Symptoms Index, and physical/mental health visual analogue scales. We examined the construct validity of the SF-12v2 through confirmatory factor analyses (CFA), and using ANOVA/correlation analyses to compare the SF-12v2 to the other instruments to ascertain discriminant/convergent validity. Our CFA showed that the measurement properties of the original SF-12v2 model had a mediocre fit with our empirical data (χ2 = 193.6, df = 43, p physical and mental health status for a homeless population with mental illness.

  8. Parents' self-efficacy, outcome expectations, and self-reported task performance when managing atopic dermatitis in children: instrument reliability and validity.

    Science.gov (United States)

    Mitchell, Amy E; Fraser, Jennifer A

    2011-02-01

    Support and education for parents faced with managing a child with atopic dermatitis is crucial to the success of current treatments. Interventions aiming to improve parent management of this condition are promising. Unfortunately, evaluation is hampered by lack of precise research tools to measure change. To develop a suite of valid and reliable research instruments to appraise parents' self-efficacy for performing atopic dermatitis management tasks; outcome expectations of performing management tasks; and self-reported task performance in a community sample of parents of children with atopic dermatitis. The Parents' Eczema Management Scale (PEMS) and the Parents' Outcome Expectations of Eczema Management Scale (POEEMS) were developed from an existing self-efficacy scale, the Parental Self-Efficacy with Eczema Care Index (PASECI). Each scale was presented in a single self-administered questionnaire, to measure self-efficacy, outcome expectations, and self-reported task performance related to managing child atopic dermatitis. Each was tested with a community sample of parents of children with atopic dermatitis, and psychometric evaluation of the scales' reliability and validity was conducted. A community-based convenience sample of 120 parents of children with atopic dermatitis completed the self-administered questionnaire. Participants were recruited through schools across Australia. Satisfactory internal consistency and test-retest reliability was demonstrated for all three scales. Construct validity was satisfactory, with positive relationships between self-efficacy for managing atopic dermatitis and general perceived self-efficacy; self-efficacy for managing atopic dermatitis and self-reported task performance; and self-efficacy for managing atopic dermatitis and outcome expectations. Factor analyses revealed two-factor structures for PEMS and PASECI alike, with both scales containing factors related to performing routine management tasks, and managing the

  9. Psychometric Properties of a Self-Report Instrument for the Assessment of Tic Severity in Adults With Tic Disorders.

    Science.gov (United States)

    Abramovitch, Amitai; Reese, Hannah; Woods, Douglas W; Peterson, Alan; Deckersbach, Thilo; Piacentini, John; Scahill, Lawrence; Wilhelm, Sabine

    2015-11-01

    The gold-standard measure of tic severity in tic disorders (TD), the Yale Global Tic Severity Scale (YGTSS), is a semistructured clinician-administered interview that can be time consuming and requires highly trained interviewers. Moreover, the YGTSS does not provide information regarding frequency and intensity of specific tics because all motor and all vocal tics are rated as a group. The aim of the present study is to describe and test the Adult Tic Questionnaire (ATQ), a measure for the assessment of tic severity in adults, and to report its preliminary psychometric properties. The ATQ is a brief self-report questionnaire that provides information regarding frequency, intensity, and severity of 27 specific tics. In addition, the ATQ produces total frequency, intensity, and severity scores for vocal and motor tics, as well as a global total tic severity score. Results showed that the ATQ demonstrated very good internal consistency and temporal stability. The total, vocal, and motor tic severity scales of the ATQ showed strong correlation with corresponding subscales of the YGTSS, indicating strong convergent validity. Weak correlations with measures of severity of obsessive-compulsive disorder and attention deficit/hyperactivity disorder, indicated strong discriminant validity. The ATQ, a promising measure for the assessment of tic severity in adults with TD, may be a valuable supplement to the current recommended assessment battery for TD. Furthermore, the ATQ enables clinicians and researchers to track changes in the frequency and intensity of specific tics, which is important given their complex and dynamic nature. Copyright © 2015. Published by Elsevier Ltd.

  10. Measuring adolescents' HRQoL via self reports and parent proxy reports: an evaluation of the psychometric properties of both versions of the KINDL-R instrument.

    Science.gov (United States)

    Erhart, Michael; Ellert, Ute; Kurth, Bärbel-Maria; Ravens-Sieberer, Ulrike

    2009-08-26

    Several instruments are available to assess children's health-related quality of life (HRQoL) based on self reports as well as proxy reports from parents. Previous studies have found only low-to-moderate agreement between self and proxy reports, but few studies have explicitly compared the psychometric qualities of both. This study compares the reliability, factorial validity and convergent and known group validity of the self-report and parent-report versions of the HRQoL KINDL-R questionnaire for children and adolescents. Within the nationally representative cross-sectional German Health Interview and Examination Survey for Children and Adolescents (KiGGS), 6,813 children and adolescents aged 11 to 17 years completed the KINDL-R generic HRQoL instrument while their parents answered the KINDL proxy version (both in paper-and-pencil versions). Cronbach's alpha and confirmatory factor-analysis models (linear structural equation model) were obtained. Convergent and discriminant validity were assessed by calculating the Pearson's correlation coefficient for the Strengths and Difficulties Questionnaire. Known-groups differences were examined (ANOVA) for obese children and children with a lower familial socio-economic status. The parent reports achieved slightly higher Cronbach's alpha values for the total score (0.86 vs. 0.83) and most sub-scores. Confirmatory factor analysis revealed an acceptable fit of the six-dimensional measurement model of the KINDL for the parent (RMSEA=0.07) and child reports (RMSEA=0.06). Factorial invariance across the two versions did not hold with regards to the pattern of loadings, the item errors and the covariation between latent concepts. However the magnitude of the differences was rather small. The parent report version achieved slightly higher convergent validity (r=0.44-0.63 vs. r=0.33-0.59) in the Strengths and Difficulties Questionnaire. No clear differences were observed for known-groups validity. Our study showed that parent

  11. Measuring adolescents' HRQoL via self reports and parent proxy reports: an evaluation of the psychometric properties of both versions of the KINDL-R instrument

    Directory of Open Access Journals (Sweden)

    Ravens-Sieberer Ulrike

    2009-08-01

    Full Text Available Abstract Background Several instruments are available to assess children's health-related quality of life (HRQoL based on self reports as well as proxy reports from parents. Previous studies have found only low-to-moderate agreement between self and proxy reports, but few studies have explicitly compared the psychometric qualities of both. This study compares the reliability, factorial validity and convergent and known group validity of the self-report and parent-report versions of the HRQoL KINDL-R questionnaire for children and adolescents. Methods Within the nationally representative cross-sectional German Health Interview and Examination Survey for Children and Adolescents (KiGGS, 6,813 children and adolescents aged 11 to 17 years completed the KINDL-R generic HRQoL instrument while their parents answered the KINDL proxy version (both in paper-and-pencil versions. Cronbach's alpha and confirmatory factor-analysis models (linear structural equation model were obtained. Convergent and discriminant validity were assessed by calculating the Pearson's correlation coefficient for the Strengths and Difficulties Questionnaire. Known-groups differences were examined (ANOVA for obese children and children with a lower familial socio-economic status. Results The parent reports achieved slightly higher Cronbach's alpha values for the total score (0.86 vs. 0.83 and most sub-scores. Confirmatory factor analysis revealed an acceptable fit of the six-dimensional measurement model of the KINDL for the parent (RMSEA = 0.07 and child reports (RMSEA = 0.06. Factorial invariance across the two versions did not hold with regards to the pattern of loadings, the item errors and the covariation between latent concepts. However the magnitude of the differences was rather small. The parent report version achieved slightly higher convergent validity (r = 0.44 – 0.63 vs. r = 0.33 – 0.59 in the Strengths and Difficulties Questionnaire. No clear differences were

  12. Simulation tools for detector and instrument design

    DEFF Research Database (Denmark)

    Kanaki, Kalliopi; Kittelmann, Thomas; Cai, Xiao Xiao

    2018-01-01

    The high performance requirements at the European Spallation Source have been driving the technological advances on the neutron detector front. Now more than ever is it important to optimize the design of detectors and instruments, to fully exploit the ESS source brilliance. Most of the simulation...... a powerful set of tools to tailor the detector and instrument design to the instrument application....

  13. Development of a self-report physical function instrument for disability assessment: item pool construction and factor analysis.

    Science.gov (United States)

    McDonough, Christine M; Jette, Alan M; Ni, Pengsheng; Bogusz, Kara; Marfeo, Elizabeth E; Brandt, Diane E; Chan, Leighton; Meterko, Mark; Haley, Stephen M; Rasch, Elizabeth K

    2013-09-01

    To build a comprehensive item pool representing work-relevant physical functioning and to test the factor structure of the item pool. These developmental steps represent initial outcomes of a broader project to develop instruments for the assessment of function within the context of Social Security Administration (SSA) disability programs. Comprehensive literature review; gap analysis; item generation with expert panel input; stakeholder interviews; cognitive interviews; cross-sectional survey administration; and exploratory and confirmatory factor analyses to assess item pool structure. In-person and semistructured interviews and Internet and telephone surveys. Sample of SSA claimants (n=1017) and a normative sample of adults from the U.S. general population (n=999). Not applicable. Model fit statistics. The final item pool consisted of 139 items. Within the claimant sample, 58.7% were white; 31.8% were black; 46.6% were women; and the mean age was 49.7 years. Initial factor analyses revealed a 4-factor solution, which included more items and allowed separate characterization of: (1) changing and maintaining body position, (2) whole body mobility, (3) upper body function, and (4) upper extremity fine motor. The final 4-factor model included 91 items. Confirmatory factor analyses for the 4-factor models for the claimant and the normative samples demonstrated very good fit. Fit statistics for claimant and normative samples, respectively, were: Comparative Fit Index=.93 and .98; Tucker-Lewis Index=.92 and .98; and root mean square error approximation=.05 and .04. The factor structure of the physical function item pool closely resembled the hypothesized content model. The 4 scales relevant to work activities offer promise for providing reliable information about claimant physical functioning relevant to work disability. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. Mechanical engineers' handbook, design, instrumentation, and controls

    CERN Document Server

    Kutz, Myer

    2015-01-01

    Full coverage of electronics, MEMS, and instrumentation andcontrol in mechanical engineering This second volume of Mechanical Engineers' Handbookcovers electronics, MEMS, and instrumentation and control, givingyou accessible and in-depth access to the topics you'll encounterin the discipline: computer-aided design, product design formanufacturing and assembly, design optimization, total qualitymanagement in mechanical system design, reliability in themechanical design process for sustainability, life-cycle design,design for remanufacturing processes, signal processing, dataacquisition and dis

  15. Depression and anxiety in patients with coronary artery disease, measured by means of self-report measures and clinician-rated instrument.

    Science.gov (United States)

    Moryś, Joanna M; Bellwon, Jerzy; Adamczyk, Katarzyna; Gruchała, Marcin

    2016-01-01

    The presence of depression symptomatology significantly deteriorates the prognosis for the patient. There are many instruments developed to measure depression and anxiety in clinical trials; however, the suitability of the specific scale for screening these disorders in cardiovascular patients is debatable. The aim of current study is to verify which of the major assessment instruments is the most relevant for the screening evaluation of depression and anxiety in patients with cardiovascular system diseases. The sample studied consisted of 120 patients with stable coronary artery disease (CAD). They did not display serious psychiatric or somatic disorders. To assess depressive and anxiety symptoms we used self-reporting measures (BDI-II, HADS, SSAI/STAI, and PHQ), the results of which were compared to results obtained on the basis of a clinician-rating instrument (HRSD). We found that depressive symptoms assessed on the basis of HRSD, BDI-II, and PHQ-9 were equivalent in results, while the results obtained in HADS-D were significantly lower. Anxiety symptoms were found at approximate levels in HADS, SSAI, and GAD-7. The assessment of somatic symptoms in patients with CAD indicates that 87.5% of the subjects reported somatic symptoms of various intensity. Screening assessment of depression in patients with CAD gives different results depending on the tool used. We found that HADS significantly underestimates the percentage of patients with symptoms of depression in patients with CAD. Assessing anxiety symptoms with the aid of HADS gave outcomes close to the results gained by use of other tools.

  16. Conceptual design of safety instrumentation for PFBR

    International Nuclear Information System (INIS)

    Muralikrishna, G.; Seshadri, U.; Raghavan, K.

    1996-01-01

    Instrumentation systems enable monitoring of the process which in turn enables control and shutdown of the process as per the requirements. Safety Instrumentation due to its vital importance has a stringent role and this needs to be designed methodically. This paper presents the details of the conceptual design for PFBR. (author). 4 figs, 3 tabs

  17. Design requirements for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2013-01-01

    The Stratospheric Wind Interferometer for Transport studies (SWIFT) instrument is a proposed limb-viewing satellite instrument that employs the method of Doppler Michelson interferometry to measure stratospheric wind velocities and ozone densities in the altitude range of 15–45 km. The values of the main instrument parameters including filter system parameters and Michelson interferometer parameters are derived using simulations and analyses. The system design requirements for the instrument and spacecraft are presented and discussed. Some of the retrieval-imposed design requirements are also discussed. Critical design issues are identified. The design optimization process is described. The sensitivity of wind measurements to instrument characteristics is investigated including the impact on critical design issues. Using sensitivity analyses, the instrument parameters were iteratively optimized in order to meet the science objectives. It is shown that wind measurements are sensitive to the thermal sensitivity of the instrument components, especially the narrow filter and the Michelson interferometer. The optimized values of the main system parameters including Michelson interferometer optical path difference, instrument visibility, instrument responsivity and knowledge of spacecraft velocity are reported. This work also shows that the filter thermal drift and the Michelson thermal drift are two main technical risks. (paper)

  18. The Healthy Aging Brain Care (HABC Monitor: validation of the Patient Self-Report Version of the clinical tool designed to measure and monitor cognitive, functional, and psychological health

    Directory of Open Access Journals (Sweden)

    Monahan PO

    2014-12-01

    Full Text Available Patrick O Monahan,1 Catherine A Alder,2–4 Babar A Khan,1–3 Timothy Stump,1 Malaz A Boustani1–4 1Indiana University School of Medicine, Indianapolis, IN, USA; 2Indiana University Center for Aging Research, Indianapolis, IN, USA; 3Regenstrief Institute Inc., Indianapolis, IN, USA; 4Eskenazi Health, Indianapolis, IN, USA Background: Primary care providers need an inexpensive, simple, user-friendly, easily standardized, sensitive to change, and widely available multidomain instrument to measure the cognitive, functional, and psychological symptoms of patients suffering from multiple chronic conditions. We previously validated the Caregiver Report Version of the Healthy Aging Brain Care Monitor (HABC Monitor for measuring and monitoring the severity of symptoms through caregiver reports. The purpose of this study was to assess the reliability and validity of the Patient Self-Report Version of the HABC Monitor (Self-Report HABC Monitor.Design: Cross-sectional study.Setting: Primary care clinics affiliated with a safety net urban health care system in Indianapolis, Indiana, USA.Subjects: A total of 291 subjects aged ≥65 years with a mean age of 72.7 (standard deviation 6.2 years, 76% female, and 56% African Americans.Analysis: Psychometric validity and reliability of the Self-Report HABC Monitor.Results: Among 291 patients analyzed, the Self-Report HABC Monitor demonstrated excellent fit for the confirmatory factor analysis model (root mean square error of approximation =0.030, comparative fit index =0.974, weighted root mean square residual =0.837 and good internal consistency (0.78–0.92. Adequate convergent–divergent validity (differences between the Telephone Interview for Cognitive Status test-based cognitive function impairment versus nonimpairment groups was demonstrated only when patients were removed from analysis if they had both cognitive function test impairment and suspiciously perfect self-report HABC Monitor cognitive floor

  19. Development and reliability testing of a self-report instrument to measure the office layout as a correlate of occupational sitting

    Directory of Open Access Journals (Sweden)

    Duncan Mitch J

    2013-02-01

    Full Text Available Abstract Background Spatial configurations of office environments assessed by Space Syntax methodologies are related to employee movement patterns. These methods require analysis of floors plans which are not readily available in large population-based studies or otherwise unavailable. Therefore a self-report instrument to assess spatial configurations of office environments using four scales was developed. Methods The scales are: local connectivity (16 items, overall connectivity (11 items, visibility of co-workers (10 items, and proximity of co-workers (5 items. A panel cohort (N = 1154 completed an online survey, only data from individuals employed in office-based occupations (n = 307 were used to assess scale measurement properties. To assess test-retest reliability a separate sample of 37 office-based workers completed the survey on two occasions 7.7 (±3.2 days apart. Redundant scale items were eliminated using factor analysis; Chronbach’s α was used to evaluate internal consistency and test re-test reliability (retest-ICC. ANOVA was employed to examine differences between office types (Private, Shared, Open as a measure of construct validity. Generalized Linear Models were used to examine relationships between spatial configuration scales and the duration of and frequency of breaks in occupational sitting. Results The number of items on all scales were reduced, Chronbach’s α and ICCs indicated good scale internal consistency and test re-test reliability: local connectivity (5 items; α = 0.70; retest-ICC = 0.84, overall connectivity (6 items; α = 0.86; retest-ICC = 0.87, visibility of co-workers (4 items; α = 0.78; retest-ICC = 0.86, and proximity of co-workers (3 items; α = 0.85; retest-ICC = 0.70. Significant (p ≤ 0.001 differences, in theoretically expected directions, were observed for all scales between office types, except overall connectivity. Significant associations were

  20. Development of a self-report questionnaire designed for population-based surveillance of gingivitis in adolescents: assessment of content validity and reliability

    Science.gov (United States)

    QUIROZ, Viviana; REINERO, Daniela; HERNÁNDEZ, Patricia; CONTRERAS, Johanna; VERNAL, Rolando; CARVAJAL, Paola

    2017-01-01

    Abstract The major infectious diseases in Chile encompass the periodontal diseases, with a combined prevalence that rises up to 90% of the population. Thus, the population-based surveillance of periodontal diseases plays a central role for assessing their prevalence and for planning, implementing, and evaluating preventive and control programs. Self-report questionnaires have been proposed for the surveillance of periodontal diseases in adult populations world-wide. Objective This study aimed to develop and assess the content validity and reliability of a cognitively adapted self-report questionnaire designed for surveillance of gingivitis in adolescents. Material and Methods Ten predetermined self-report questions evaluating early signs and symptoms of gingivitis were preliminary assessed by a panel of clinical experts. Eight questions were selected and cognitively tested in 20 adolescents aged 12 to 18 years from Santiago de Chile. The questionnaire was then conducted and answered by 178 Chilean adolescents. Internal consistency was measured using the Cronbach’s alpha and temporal stability was calculated using the Kappa-index. Results A reliable final self-report questionnaire consisting of 5 questions was obtained, with a total Cronbach’s alpha of 0.73 and a Kappa-index ranging from 0.41 to 0.77 between the different questions. Conclusions The proposed questionnaire is reliable, with an acceptable internal consistency and a temporal stability from moderate to substantial, and it is promising for estimating the prevalence of gingivitis in adolescents. PMID:28877279

  1. Development of a self-report questionnaire designed for population-based surveillance of gingivitis in adolescents: assessment of content validity and reliability

    Directory of Open Access Journals (Sweden)

    Viviana QUIROZ

    Full Text Available Abstract The major infectious diseases in Chile encompass the periodontal diseases, with a combined prevalence that rises up to 90% of the population. Thus, the population-based surveillance of periodontal diseases plays a central role for assessing their prevalence and for planning, implementing, and evaluating preventive and control programs. Self-report questionnaires have been proposed for the surveillance of periodontal diseases in adult populations world-wide. Objective This study aimed to develop and assess the content validity and reliability of a cognitively adapted self-report questionnaire designed for surveillance of gingivitis in adolescents. Material and Methods Ten predetermined self-report questions evaluating early signs and symptoms of gingivitis were preliminary assessed by a panel of clinical experts. Eight questions were selected and cognitively tested in 20 adolescents aged 12 to 18 years from Santiago de Chile. The questionnaire was then conducted and answered by 178 Chilean adolescents. Internal consistency was measured using the Cronbach’s alpha and temporal stability was calculated using the Kappa-index. Results A reliable final self-report questionnaire consisting of 5 questions was obtained, with a total Cronbach’s alpha of 0.73 and a Kappa-index ranging from 0.41 to 0.77 between the different questions. Conclusions The proposed questionnaire is reliable, with an acceptable internal consistency and a temporal stability from moderate to substantial, and it is promising for estimating the prevalence of gingivitis in adolescents.

  2. Instrument design and optimization using genetic algorithms

    International Nuclear Information System (INIS)

    Hoelzel, Robert; Bentley, Phillip M.; Fouquet, Peter

    2006-01-01

    This article describes the design of highly complex physical instruments by using a canonical genetic algorithm (GA). The procedure can be applied to all instrument designs where performance goals can be quantified. It is particularly suited to the optimization of instrument design where local optima in the performance figure of merit are prevalent. Here, a GA is used to evolve the design of the neutron spin-echo spectrometer WASP which is presently being constructed at the Institut Laue-Langevin, Grenoble, France. A comparison is made between this artificial intelligence approach and the traditional manual design methods. We demonstrate that the search of parameter space is more efficient when applying the genetic algorithm, and the GA produces a significantly better instrument design. Furthermore, it is found that the GA increases flexibility, by facilitating the reoptimization of the design after changes in boundary conditions during the design phase. The GA also allows the exploration of 'nonstandard' magnet coil geometries. We conclude that this technique constitutes a powerful complementary tool for the design and optimization of complex scientific apparatus, without replacing the careful thought processes employed in traditional design methods

  3. Instrument design and optimization using genetic algorithms

    Science.gov (United States)

    Hölzel, Robert; Bentley, Phillip M.; Fouquet, Peter

    2006-10-01

    This article describes the design of highly complex physical instruments by using a canonical genetic algorithm (GA). The procedure can be applied to all instrument designs where performance goals can be quantified. It is particularly suited to the optimization of instrument design where local optima in the performance figure of merit are prevalent. Here, a GA is used to evolve the design of the neutron spin-echo spectrometer WASP which is presently being constructed at the Institut Laue-Langevin, Grenoble, France. A comparison is made between this artificial intelligence approach and the traditional manual design methods. We demonstrate that the search of parameter space is more efficient when applying the genetic algorithm, and the GA produces a significantly better instrument design. Furthermore, it is found that the GA increases flexibility, by facilitating the reoptimization of the design after changes in boundary conditions during the design phase. The GA also allows the exploration of "nonstandard" magnet coil geometries. We conclude that this technique constitutes a powerful complementary tool for the design and optimization of complex scientific apparatus, without replacing the careful thought processes employed in traditional design methods.

  4. Signal conditioning circuitry design for instrumentation systems.

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Cory A.

    2012-01-01

    This report details the current progress in the design, implementation, and validation of the signal conditioning circuitry used in a measurement instrumentation system. The purpose of this text is to document the current progress of a particular design in signal conditioning circuitry in an instrumentation system. The input of the signal conditioning circuitry comes from a piezoresistive transducer and the output will be fed to a 250 ksps, 12-bit analog-to-digital converter (ADC) with an input range of 0-5 V. It is assumed that the maximum differential voltage amplitude input from the sensor is 20 mV with an unknown, but presumably high, sensor bandwidth. This text focuses on a specific design; however, the theory is presented in such a way that this text can be used as a basis for future designs.

  5. Development of a self-report questionnaire designed for population-based surveillance of gingivitis in adolescents: assessment of content validity and reliability.

    Science.gov (United States)

    Quiroz, Viviana; Reinero, Daniela; Hernández, Patricia; Contreras, Johanna; Vernal, Rolando; Carvajal, Paola

    2017-01-01

    This study aimed to develop and assess the content validity and reliability of a cognitively adapted self-report questionnaire designed for surveillance of gingivitis in adolescents. Ten predetermined self-report questions evaluating early signs and symptoms of gingivitis were preliminary assessed by a panel of clinical experts. Eight questions were selected and cognitively tested in 20 adolescents aged 12 to 18 years from Santiago de Chile. The questionnaire was then conducted and answered by 178 Chilean adolescents. Internal consistency was measured using the Cronbach's alpha and temporal stability was calculated using the Kappa-index. A reliable final self-report questionnaire consisting of 5 questions was obtained, with a total Cronbach's alpha of 0.73 and a Kappa-index ranging from 0.41 to 0.77 between the different questions. The proposed questionnaire is reliable, with an acceptable internal consistency and a temporal stability from moderate to substantial, and it is promising for estimating the prevalence of gingivitis in adolescents.

  6. A new design of neutron survey instrument

    International Nuclear Information System (INIS)

    Tanner, R.J.; Eakins, J.S.; Hager, L.G.

    2010-01-01

    A novel design of neutron survey instrument has been developed. The moderator has been modified via the use of 'neutron guides', which help thermal neutrons reach the central proportional counter. This innovation has allowed the variations in the energy dependence of ambient dose equivalent response to be reduced compared to prior single-detector designs, whilst maintaining a relatively light moderator and simple construction. In particular, the design has a relatively small over-response to neutrons with energies around 5 keV, when compared to prior designs. The final optimized design has been verified using MCNP5 calculations to ensure that the response is relatively independent of the energy and direction of the incident neutron. This has required the ends of the guides to be structured so that unidirectional and isotropic neutron fields have closely matched responses, as is necessary in the workplace. The reading of the instrument in workplace fields is calculated via folding and the suitability of the design for use in the workplace discussed.

  7. Psychosocial measures used to assess the effectiveness of school-based nutrition education programs: review and analysis of self-report instruments for children 8 to 12 years old.

    Science.gov (United States)

    Hernández-Garbanzo, Yenory; Brosh, Joanne; Serrano, Elena L; Cason, Katherine L; Bhattarai, Ranju

    2013-01-01

    To identify the psychometric properties of evaluation instruments that measure mediators of dietary behaviors in school-aged children. Systematic search of scientific databases limited to 1999-2010. Psychometric properties related to development and testing of self-report instruments for children 8-12 years old. Systematic search of 189 articles and review of 15 instruments (20 associated articles) meeting the inclusion criteria. Search terms used included children, school, nutrition, diet, nutrition education, and evaluation. Fourteen studies used a theoretical framework to guide the instrument's development. Knowledge and self-efficacy were the most commonly used psychosocial measures. Twelve instruments focused on specific nutrition-related behaviors. Eight instruments included over 40 items and used age-appropriate response formats. Acceptable reliability properties were most commonly reported for attitude and self-efficacy measures. Although most of the instruments were reviewed by experts (n = 8) and/or pilot-tested (n = 9), only 7 were tested using both rigorous types of validity and with low-income youth. Results from this review suggest that additional research is needed to develop more robust psychosocial measures for dietary behaviors, for low-income youth audiences. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  8. A Light-Weight Instrumentation System Design

    International Nuclear Information System (INIS)

    Kidner, Ronald

    1999-01-01

    To meet challenging constraints on telemetry system weight and volume, a custom Light-Weight Instrumentation System was developed to collect vehicle environment and dynamics on a short-duration exo-atmospheric flight test vehicle. The total telemetry system, including electronics, sensors, batteries, and a 1 watt transmitter weighs about 1 kg. Over 80 channels of measurement, housekeeping, and telemetry system diagnostic data are transmitted at 128 kbps. The microcontroller-based design uses the automotive industry standard Controller Area Network to interface with and support in-flight control fimctions. Operational parameters are downloaded via a standard asynchronous serial communications intefiace. The basic design philosophy and functionality is described here

  9. Design principles for radiological protection instrumentation systems

    International Nuclear Information System (INIS)

    Wells, F.H.; Powell, R.G.

    1981-02-01

    This Code of Practice takes the form of recommendations intended for designers and installers of Radiological Protection Instrumentation, and should also be of value to the newcomer to the R.P.I. field. Topics are discussed under the following headings: outline of R.P.I. requirements, specifying the requirement, satisfying the requirements, (overall design, availability and reliability, information display, human factors, power supplies, manufacture, quality assurance, testing, and cost analysis), supply, location and operation of the equipment, importance of documentation. (U.K.)

  10. Self-reported accidents

    DEFF Research Database (Denmark)

    Møller, Katrine Meltofte; Andersen, Camilla Sloth

    2016-01-01

    The main idea behind the self-reporting of accidents is to ask people about their traffic accidents and gain knowledge on these accidents without relying on the official records kept by police and/or hospitals.......The main idea behind the self-reporting of accidents is to ask people about their traffic accidents and gain knowledge on these accidents without relying on the official records kept by police and/or hospitals....

  11. Evaluation of the measurement properties of self-reported health-related work-functioning instruments among workers with common mental disorders

    NARCIS (Netherlands)

    Abma, F.I.; van der Klink, J.J.L.; Terwee, C.B.; Amick, B.C.; Bultmann, U.

    2012-01-01

    Objectives During the past decade, common mental disorders (CMD) have emerged as a major public and occupational health problem in many countries. Several instruments have been developed to measure the influence of health on functioning at work. To select appropriate instruments for use in

  12. Design of nuclear instruments for industrial use

    International Nuclear Information System (INIS)

    Maggio, G.E.

    1988-01-01

    Following an introduction to the atomic structure and the radioactive desintegration, the applications of radioisotopic sealed sources are described. The laws that govern the interaction of radiation with matter and the statistics applied to the radioactive measurements are presented. Different measurement techniques, basic equations of design, the way to provide the activity calculation of a source and the detector's characteristics are given, according to the parameters to be measured and the conditions imposed. Finally, the principles of operation and the most important characteristics of different nuclear instruments to be used in industrial measurements are described. (Author) [es

  13. Designer's handbook of instrumentation and control circuits

    CERN Document Server

    Carr, Joseph J

    1991-01-01

    Here is a comprehensive, practical guide to the entire process of analog instrumentation and control, from sensor input to data conversion circuitry and final output. This readable handbook avoids complex mathematical treatments, instead taking an applications-oriented approach and presenting many sample circuits and concrete examples. It is an essential reference for engineers and high-level technicians in a variety of scientific and engineering fields--anywhere data is collected electronically and where such data is used to control physical processes.Key Features* Covers design o

  14. Tank SY-101 void fraction instrument functional design criteria

    International Nuclear Information System (INIS)

    McWethy, L.M.

    1994-01-01

    This document presents the functional design criteria for design, analysis, fabrication, testing, and installation of a void fraction instrument for Tank SY-101. This instrument will measure the void fraction in the waste in Tank SY-101 at various elevations

  15. Water NSTF Design, Instrumentation, and Test Planning

    Energy Technology Data Exchange (ETDEWEB)

    Lisowski, Darius D.; Gerardi, Craig D.; Hu, Rui; Kilsdonk, Dennis J.; Bremer, Nathan C.; Lomperski, Stephen W.; Kraus, Adam R.; Bucknor, Matthew D.; Lv, Qiuping; Farmer, Mitchell T.

    2017-08-01

    variations and off-normal configurations. The facility design follows, including as-built dimensions and specifications of the various mechanical and liquid systems, design choices for the test section, water storage tank, and network piping. Specifications of the instrumentation suite are then presented, along with specific information on performance windows, measurement uncertainties, and installation locations. Finally, descriptions of the control systems and heat removal networks are provided, which have been engineered to support precise quantification of energy balances and facilitate well-controlled test operations.

  16. LOFT instrumented fuel design and operating experience

    International Nuclear Information System (INIS)

    Russell, M.L.

    1979-01-01

    A summary description of the Loss-of-Fluid Test (LOFT) system instrumented core construction details and operating experience through reactor startup and loss-of-coolant experiment (LOCE) operations performed to date are discussed. The discussion includes details of the test instrumentation attachment to the fuel assembly, the structural response of the fuel modules to the forces generated by a double-ended break of a pressurized water reactor (PWR) coolant pipe at the inlet to the reactor vessel, the durability of the LOFT fuel and test instrumentation, and the plans for incorporation of improved fuel assembly test instrumentation features in the LOFT core

  17. Instrument design optimization with computational methods

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Michael H. [Old Dominion Univ., Norfolk, VA (United States)

    2017-08-01

    Using Finite Element Analysis to approximate the solution of differential equations, two different instruments in experimental Hall C at the Thomas Jefferson National Accelerator Facility are analyzed. The time dependence of density uctuations from the liquid hydrogen (LH2) target used in the Qweak experiment (2011-2012) are studied with Computational Fluid Dynamics (CFD) and the simulation results compared to data from the experiment. The 2.5 kW liquid hydrogen target was the highest power LH2 target in the world and the first to be designed with CFD at Jefferson Lab. The first complete magnetic field simulation of the Super High Momentum Spectrometer (SHMS) is presented with a focus on primary electron beam deflection downstream of the target. The SHMS consists of a superconducting horizontal bending magnet (HB) and three superconducting quadrupole magnets. The HB allows particles scattered at an angle of 5:5 deg to the beam line to be steered into the quadrupole magnets which make up the optics of the spectrometer. Without mitigation, remnant fields from the SHMS may steer the unscattered beam outside of the acceptable envelope on the beam dump and limit beam operations at small scattering angles. A solution is proposed using optimal placement of a minimal amount of shielding iron around the beam line.

  18. Design of a instrumentation module for monitoring ingestive behavior in laboratory studies.

    Science.gov (United States)

    Fontana, Juan M; Lopez-Meyer, Paulo; Sazonov, Edward S

    2011-01-01

    The development of accurate and objective tools for monitoring of ingestive behavior (MIB) is one of the most important needs facing studies of obesity and eating disorders. This paper presents the design of an instrumentation module for non-invasive monitoring of food ingestion in laboratory studies. The system can capture signals from a variety of sensors that characterize ingestion process (such as acoustical and other swallowing sensors, strain sensor for chewing detection and self-report buttons). In addition to the sensors, the data collection system integrates time-synchronous video footage that can be used for annotation of subject's activity. Both data and video are simultaneously and synchronously acquired and stored by a LabVIEW-based interface specifically developed for this application. This instrumentation module improves a previously developed system by eliminating the post-processing stage of data synchronization and by reducing the risks of operator's error.

  19. Design of economic incentive instruments in nutrition policy

    DEFF Research Database (Denmark)

    Jensen, Jørgen Dejgård

    2011-01-01

    • Economic incentives are instruments to improve diets and reduce the fraction of people exposed to diet-related health risks • Proper targeting and design of economic incentive instruments is important, if such instruments should be efficient and feasible policy measures in the improvement...... of dietary behaviour in industrialised countries • From a cost-effectiveness perspective, there are considerable potential for optimizing the targeting and design of economic incentive instruments in nutritional policy...

  20. Designing communication and remote controlling of virtual instrument network system

    Science.gov (United States)

    Lei, Lin; Wang, Houjun; Zhou, Xue; Zhou, Wenjian

    2005-01-01

    In this paper, a virtual instrument network through the LAN and finally remote control of virtual instruments is realized based on virtual instrument and LabWindows/CVI software platform. The virtual instrument network system is made up of three subsystems. There are server subsystem, telnet client subsystem and local instrument control subsystem. This paper introduced virtual instrument network structure in detail based on LabWindows. Application procedure design of virtual instrument network communication, the Client/the programming mode of the server, remote PC and server communication far realizing, the control power of the workstation is transmitted, server program and so on essential technical were introduced. And virtual instruments network may connect to entire Internet on. Above-mentioned technology, through measuring the application in the electronic measurement virtual instrument network that is already built up, has verified the actual using value of the technology. Experiment and application validate that this design is resultful.

  1. Designing communication and remote controlling of virtual instrument network system

    International Nuclear Information System (INIS)

    Lei Lin; Wang Houjun; Zhou Xue; Zhou Wenjian

    2005-01-01

    In this paper, a virtual instrument network through the LAN and finally remote control of virtual instruments is realized based on virtual instrument and LabWindows/CVI software platform. The virtual instrument network system is made up of three subsystems. There are server subsystem, telnet client subsystem and local instrument control subsystem. This paper introduced virtual instrument network structure in detail based on LabWindows. Application procedure design of virtual instrument network communication, the Client/the programming mode of the server, remote PC and server communication far realizing, the control power of the workstation is transmitted, server program and so on essential technical were introduced. And virtual instruments network may connect to entire Internet on. Above-mentioned technology, through measuring the application in the electronic measurement virtual instrument network that is already built up, has verified the actual using value of the technology. Experiment and application validate that this design is resultful

  2. The Basic Design Report of the 40M SANS Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young Soo; Lee, Chang Hee; Hwang, Dong Gil; Kim, Hak Rho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Tae Hwan; Choi, Sung Min [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2006-04-15

    The HANARO cold neutron research facility project was launched on July 1, 2003. A state of the art SANS instrument was selected as a top-priority instrument by an instrument selection committee, which consisted of domestic users and HANARO personnel. An instrument development team and an international and domestic instrument advisory team were formulated. The guide and the instrument simulation were performed using Vitess software and the optimum basic design was completed based on the simulation results and the international advisory team reviews. The optimum design of the guide for the 40M SANS instrument was completed and the optimum basic design of the 40M the SANS instrument was also completed based on the Vitess simulation results. The Q range of the instrument will cover from 0.0008 to 1.0 A-1 and the maximum flux at a sample position can reach about 5.5x10 7 n/cm2sec. The simulation results and the basic design product will be used for the detailed design and the construction of the SANS instrument. The simulation results could be applied to the development of the other instrument.

  3. FMIT test-end instrumentation conceptual design

    International Nuclear Information System (INIS)

    Fuller, J.L.

    1984-08-01

    FMIT test-end measurement techniques and instrumentation concepts for deuteron beam control, test-end device protection, test cell radiation field characterization, lithium jet performance monitoring, and in-situ off-line target testing and examination are described. The test-end refers to the beam line-target-test assembly interface area inside the test cell, but TEI includes measurements inside and outside the cell. The measurement requirements are briefly reviewed and referenced. The sometimes severe environmental limitations are discussed. Where feasible, multifunctional systems have been configured. Special facility features have been minimized

  4. Musical Instrument Design Process for Mobile Technology

    OpenAIRE

    Barraclough, Timothy J.; Carnegie, Dale A.; Kapur, Ajay

    2015-01-01

    This paper presents the iterative design process based upon multiple rounds of user studies that guided the the design of a novel social music application, Pyxis Minor. The application was designed based on the concept of democratising electronic music creation and performance. This required the development to be based upon user studies to inform and drive the development process in order to create a novel musical interface that can be enjoyed by users of any prior musicianship training.

  5. Die Casting Mold Design for Aluminum Alloy Shell of Instrument

    Directory of Open Access Journals (Sweden)

    Li Yuanyuan

    2015-01-01

    Full Text Available This paper is about die casting mold design for aluminum alloy shell of instrument. Three-dimensional model of the casting and mold are designed by using Pro/Engineer and AutoCad which can analyze forming quality. Digital design and theoretical calculation can greatly shorten product development cycle and mold design cycle, improve the accuracy of product design and mold design, and reduce the cost of mold design.

  6. Design and implementation of a wireless instrument adapter

    DEFF Research Database (Denmark)

    Laino, Kaori V.; Saathoff, Thore; Savarimuthu, Thiusius R.

    2018-01-01

    The evaluation of new methods for control and manipulation in minimally invasive robotic surgery requires a realistic setup. To decouple the evaluation of methods from overall clinical systems, we propose an instrument adapter for the S line EndoWrist\\c{opyright} instruments of the da Vinci...... surgical system. The adapter is small and lightweight and can be mounted to any robot to mimic motion. We describe its design and implementation, as well as a setup to calibrate instruments to study precise motion control. Our results indicate that each instrument requires individual calibration...

  7. Factors affecting the design of instrument flight procedures

    Directory of Open Access Journals (Sweden)

    Ivan FERENCZ

    2008-01-01

    Full Text Available The article highlights factors, which might affect the design of instrument flight procedures. Ishikawa diagram is used to distribute individual factors into classes, as are People, Methods, Regulations, Tools, Data and Environment.

  8. Design aspects of safety critical instrumentation of nuclear installations

    Energy Technology Data Exchange (ETDEWEB)

    Swaminathan, P. [Electronics Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102, Tamil Nadu (India)]. E-mail: swamy@igcar.ernet.in

    2005-07-01

    Safety critical instrumentation systems ensure safe shutdown/configuration of the nuclear installation when process status exceeds the safety threshold limits. Design requirements for safety critical instrumentation such as functional and electrical independence, fail-safe design, and architecture to ensure the specified unsafe failure rate and safe failure rate, human machine interface (HMI), etc., are explained with examples. Different fault tolerant architectures like 1/2, 2/2, 2/3 hot stand-by are compared for safety critical instrumentation. For embedded systems, software quality assurance is detailed both during design phase and O and M phase. Different software development models such as waterfall model and spiral model are explained with examples. The error distribution in embedded system is detailed. The usage of formal method is outlined to reduce the specification error. The guidelines for coding of application software are outlined. The interface problems of safety critical instrumentation with sensors, actuators, other computer systems, etc., are detailed with examples. Testability and maintainability shall be taken into account during design phase. Online diagnostics for safety critical instrumentation is detailed with examples. Salient details of design guides from Atomic Energy Regulatory Board, International Atomic Energy Agency and standards from IEEE, BIS are given towards the design of safety critical instrumentation systems. (author)

  9. Design aspects of safety critical instrumentation of nuclear installations

    International Nuclear Information System (INIS)

    Swaminathan, P.

    2005-01-01

    Safety critical instrumentation systems ensure safe shutdown/configuration of the nuclear installation when process status exceeds the safety threshold limits. Design requirements for safety critical instrumentation such as functional and electrical independence, fail-safe design, and architecture to ensure the specified unsafe failure rate and safe failure rate, human machine interface (HMI), etc., are explained with examples. Different fault tolerant architectures like 1/2, 2/2, 2/3 hot stand-by are compared for safety critical instrumentation. For embedded systems, software quality assurance is detailed both during design phase and O and M phase. Different software development models such as waterfall model and spiral model are explained with examples. The error distribution in embedded system is detailed. The usage of formal method is outlined to reduce the specification error. The guidelines for coding of application software are outlined. The interface problems of safety critical instrumentation with sensors, actuators, other computer systems, etc., are detailed with examples. Testability and maintainability shall be taken into account during design phase. Online diagnostics for safety critical instrumentation is detailed with examples. Salient details of design guides from Atomic Energy Regulatory Board, International Atomic Energy Agency and standards from IEEE, BIS are given towards the design of safety critical instrumentation systems. (author)

  10. Further Issues in Determining the Readability of Self-Report Items: Comment on McHugh and Behar (2009)

    Science.gov (United States)

    Schinka, John A.

    2012-01-01

    Objective: Issues regarding the readability of self-report assessment instruments, methods for establishing the reading ability level of respondents, and guidelines for development of scales designed for marginal readers have been inconsistently addressed in the literature. A recent study by McHugh and Behar (2009) provided new findings relevant…

  11. The design of nuclear radiation measuring instrument of embedded network

    International Nuclear Information System (INIS)

    Zhang Huaiqiang; Ge Liangquan; Xiong Shengqing

    2009-01-01

    The design and realization of nuclear radiation measuring instrument is introduced. Due to the current nuclear instrument often used serial interface to communicate the PC, it is widely used for simple design and easy operation. However, as the demand of remote data acquisition and the call of sharing resources, the design of embedded the TCP/IP protocol stack into MCU, it may send the nuclear signal in Internet. Some devices that link each other with the network can be networked. The design is not only realizing remote data acquisition and sharing resources, but also reducing costs and improving the maintainability of the system. (authors)

  12. Design of MPU based process monitoring instrument

    International Nuclear Information System (INIS)

    Ahmed, Z.; Qamar, R.; Majid, B.

    1995-03-01

    A display sub-system (DSS) for a process variable like flow is designed around Intel 8088 microprocessor. It displays the current value of a process variable but average and accumulated value display is manually selectable. The display consists of 6 units of seven segment display and accuracy up to 2 nd place of decimal is achieved. The engineering units are indicated by the LEDs. The control software is developed in assembler and burnt in a EPROM. The maximum value of the display is 9999.99 K. liter and that of time is 99 days 23 hours and 59 minutes. Sampling period is 1 second. Data acquisition is done using Polling technique. (author)

  13. Design and manufacture NCS instruments for cement factories

    International Nuclear Information System (INIS)

    Nguyen Thanh Tuy; Nguyen Tien Dung; Dang Nguyet Anh; Nguyen Phuc; Khuong Thanh Tuan; Luong Duc Long; Pham Trong Quyen

    2003-01-01

    The ministry project 'Design and manufacture some of NCS instruments for cement factories' is a part of instrumentation for cement production in Vietnam. The objectives of the project include: 1/Design and manufacture the automatic control system for cement raw material mixing, connected to components X-ray analyzer through serial port of PC; 2/Design and manufacture the automatic discharge control system using gamma rays. The instruments, made by the project , for controlling the conveyor belt weighing machine can be easily improved for various types of conveyor belt weighing machines. Their mobility and software equipped can be adapted for requirement of modern cement production technology. The instruments are operating well in some cement factories and they are helping in quality control. (NHA)

  14. Design type testing for digital instrumentation and control systems

    International Nuclear Information System (INIS)

    Bastl, W.; Mohns, G.

    1997-01-01

    The design type qualification of digital safety instrumentation and control is outlined. Experience shows that the concepts discussed, derived from codes, guidelines and standards, achieve useful results. It has likewise become clear that the systematics of design type qualification of the hardware components is also applicable to the software components. Design type qualification of the software, a premiere, could be performed unexpectedly smoothly. The hardware design type qualification proved that the hardware as a substrate of functionality and reliability is an issue that demands full attention, as compared to conventional systems. Another insight is that design qualification of digital instrumentation and control systems must include plant-independent systems tests. Digital instrumentation and control systems simply work very differently from conventional control systems, so that this testing modality is inevitable. (Orig./CB) [de

  15. Modular beam diagnostics instrument design for Cyclotrons

    International Nuclear Information System (INIS)

    Chaddha, N.; Bhole, R.B.; Sahoo, S.; Nandy, P.P.; Pal, S.

    2012-01-01

    The Cyclotrons at VECC, Kolkata i.e. Room Temperature Cyclotron (RTC) and Superconducting Cyclotron (SCC) comprise of internal and external Beam Diagnostic systems. These systems provide the beam developer with position, intensity, beam profile, a visual impression of the size and shape of ion beam, and operational control over diagnostic components like 3-finger probe, Beam Viewer probe, Deflector probe, Faraday cup, X-Y slit, Beam viewer etc. Automation of these components was initially done using customised modules for individual sub-system. An expansion of this facility and various levels of complexity demand modular design to cater easy modification and upgradation. The overall requirements are analysed and modular cards are developed based on basic functionalities like valve operation, probe/slit/viewer control, position read-out, Interlock, aperture control of beam line and communication. A 32-bit Advanced RISC Machine (ARM) based card with embedded EPICS is chosen as the master controller and FPGA/microcontroller is used for functional modules. The paper gives a comprehensive description of all modules and their integration with the control system. (author)

  16. Portable nucleonics instrument design: The PortaCAT example

    International Nuclear Information System (INIS)

    Wallace, G.; Pohl, P.; Hutchinson, E.

    2000-01-01

    Portable nucleonic gauges prototypes are designed and manufactured in New Zealand for niche applications. Considerable development in hardware and software provide new opportunity in design of relatively low cost portable nucleonic gauges. In this paper are illustrated principles, and specific factors to be consider when designing portable nucleonic instrumentation, using an example called PortaCAT, which is a portable computed tomography scanner designed for imaging wooden power poles. (author)

  17. Design of cost effective antennas for instrumentation radars

    CSIR Research Space (South Africa)

    Botha, L

    2012-09-01

    Full Text Available The cost of antennas for instrumentation radars are determined by the development cost. By re-use of the reflector system cost effective antennas can be designed. The factors governing the design of such antennas are described here....

  18. Design aid system for nuclear power plant instrumentations

    International Nuclear Information System (INIS)

    Hattori, Yoshiaki; Ito, Toshiichiro; Fujii, Makoto; Shimada, Nobuhide.

    1987-01-01

    Purpose: To enable to provide design aid for the nuclear power plant instrumentation of high reliability with the minimum cost while eliminating unrequired condition even if there are no data for the ground of the instrumentation design. Constitution: The information data base for the design of process radiation ray monitors are administrated by a data base administration device. The conditions to be satisfied in the process radiation monitors designed based on the data for the circumstances where particular predetermined process radiation monitors are installed, are derived by deduction using information obtained from the data base by way of the data base administration device. The derived design conditions are displayed and the optimum conditions are again reduced and displayed. In this way, the designers are assisted such that optimum designs can be obtained while sufficiently satisfying the safety and also in view of the cost. (Kamimura, M.)

  19. Software for simulation and design of neutron scattering instrumentation

    DEFF Research Database (Denmark)

    Bertelsen, Mads

    designed using the software. The Union components uses a new approach to simulation of samples in McStas. The properties of a sample are split into geometrical and material, simplifying user input, and allowing the construction of complicated geometries such as sample environments. Multiple scattering...... from conventional choices. Simulation of neutron scattering instrumentation is used when designing instrumentation, but also to understand instrumental effects on the measured scattering data. The Monte Carlo ray-tracing package McStas is among the most popular, capable of simulating the path of each...... neutron through the instrument using an easy to learn language. The subject of the defended thesis is contributions to the McStas language in the form of the software package guide_bot and the Union components.The guide_bot package simplifies the process of optimizing neutron guides by writing the Mc...

  20. Image reconstruction design of industrial CT instrument for teaching

    International Nuclear Information System (INIS)

    Zou Yongning; Cai Yufang

    2009-01-01

    Industrial CT instrument for teaching is applied to teaching and study in field of physics and radiology major, image reconstruction is an important part of software on CT instrument. The paper expatiate on CT physical theory and first generation CT reconstruction algorithm, describe scan process of industrial CT instrument for teaching; analyze image artifact as result of displacement of rotation center, implement method of center displacement correcting, design and complete image reconstruction software, application shows that reconstructed image is very clear and qualitatively high. (authors)

  1. Design of instrumentation and software for precise laser machining

    Science.gov (United States)

    Wyszyński, D.; Grabowski, Marcin; Lipiec, Piotr

    2017-10-01

    The paper concerns the design of instrumentation and software for precise laser machining. Application of advanced laser beam manipulation instrumentation enables noticeable improvement of cut quality and material loss. This factors have significant impact on process efficiency and cutting edge quality by means of machined part size and shape accuracy, wall taper, material loss reduction (e.g. diamond) and time effectiveness. The goal can be reached by integration of laser drive, observation and optical measurement system, beam manipulation system and five axis mechanical instrumentation with use of advanced tailored software enabling full laser cutting process control and monitoring.

  2. Self-reported bruxism mirrors anxiety and stress in adults

    NARCIS (Netherlands)

    Ahlberg, J.; Lobbezoo, F.; Ahlberg, K.; Manfredini, D.; Hublin, C.; Sinisalo, J.; Könönen, M.; Savolainen, A.

    2013-01-01

    Objectives: The aims were to analyze whether the levels of self-reported bruxism and anxiety associate among otherwise healthy subjects, and to investigate the independent effects of anxiety and stress experience on the probability of self-reported bruxism. Study Design: As part of a study on

  3. Design of reactor alarm instrument based on SOPC

    International Nuclear Information System (INIS)

    Li Meng; Lu Yi; Rong Ru

    2008-01-01

    The design of embedded alarm instrument in reactors based on Nios II CPU is introduced in this paper. This design uses the SOPC technology based on the Cyclone series FPGA as a digital bench, and connects the MPU and drivers and interface of times, RS232, sdram,and etc. into a FPGA chip. It is proved that the system achieves the design goals in primary experimentation. (authors)

  4. System 80+ instrumentation and controls - certification of a reliable design

    International Nuclear Information System (INIS)

    Matzie, R.A.; Scarola, K.; Turk, R.S.

    1993-01-01

    ABB Combustion Engineering's (ABB) System 80+ advanced light water plant design includes a modern, fully digitized instrumentation and controls complex, Nuplex 80+. This complex incorporates an evolutionary advanced control room, replacing conventional analog instruments with more capable computer driven components. As a result, Nuplex 80+ results in significant improvements in operator information handling and control to enhance plant safety and availability. The design implements features which the U.S. NRC has determined to be acceptable for addressing the potential for common mode failure in software implemented for protective functions. (author)

  5. Cold Vacuum Drying Instrument Air System Design Description (SYS 12)

    Energy Technology Data Exchange (ETDEWEB)

    SHAPLEY, B.J.; TRAN, Y.S.

    2000-06-05

    This system design description (SDD) addresses the instrument air (IA) system of the spent nuclear fuel (SNF). This IA system provides instrument quality air to the Cold Vacuum Drying (CVD) Facility. The IA system is a general service system that supports the operation of the heating, ventilation, and air conditioning (HVAC) system, the process equipment skids, and process instruments in the CVD Facility. The following discussion is limited to the compressor, dryer, piping, and valving that provide the IA as shown in Drawings H-1-82222, Cold Vacuum Drying Facility Mechanical Utilities Compressed & Instrument Air P&ID, and H-1.82161, Cold Vacuum Drying Facility Process Equipment Skid P&ID MCO/Cusk Interface. Figure 1-1 shows the physical location of the 1A system in the CVD Facility.

  6. Cold Vacuum Drying Instrument Air System Design Description. System 12

    International Nuclear Information System (INIS)

    SHAPLEY, B.J.; TRAN, Y.S.

    2000-01-01

    This system design description (SDD) addresses the instrument air (IA) system of the spent nuclear fuel (SNF). This IA system provides instrument quality air to the Cold Vacuum Drying (CVD) Facility. The IA system is a general service system that supports the operation of the heating, ventilation, and air conditioning (HVAC) system, the process equipment skids, and process instruments in the CVD Facility. The following discussion is limited to the compressor, dryer, piping, and valving that provide the IA as shown in Drawings H-1-82222, Cold Vacuum Drying Facility Mechanical Utilities Compressed and Instrument Air PandID, and H-1.82161, Cold Vacuum Drying Facility Process Equipment Skid PandID MCO/Cusk Interface. Figure 1-1 shows the physical location of the 1A system in the CVD Facility

  7. Design and validation of portable optical instrument for crop diagnose

    Science.gov (United States)

    Sun, Gang; Zheng, Wengang; Huang, Wengjiang; Wan, Huawei; Liu, Liangyun

    2005-12-01

    In this paper, a portable diagnostic instrument was designed and tested, which can measure the normalized difference vegetation index (NDVI) and structure insensitive pigment index (SIPI) of crop canopy in field. The instrument have a valid survey area of 1 m*1 m when the height between instrument and the ground was fixed to 1.3 meter The crop growth condition can be assessed based on their NDVI and SIPI values, so it will be very important for crop management to get these values. The instrument uses sunlight as its light source. There are six special different photoelectrical detectors within red, blue and near infrared bands, which are used for detecting incidence sunlight and reflex light from the canopy of crop. This optical instrument includes photoelectric detector module, signal process and A/D convert module, the data storing and transmission module and human-machine interface module. The detector is the core of the instrument which measures the spectrums at special bands. The microprocessor calculates the NDVI and SIPI value based on the A/D value. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's RS232 serial interface. The prototype was tested in the crop field at different view directions. This paper also provided the method of calibration, the results showed that the average measurement error to SIPI value of instrument was 5.25% and the average measurement error to NDVI value in vegetation-covered region is 6.40%. It reveals the on-site and non-sampling mode of crop growth monitoring by fixed on the agricultural machine traveling in the field.

  8. Conceptual design for the NSTX Central Instrumentation and Control System

    International Nuclear Information System (INIS)

    Bashore, D.; Oliaro, G.; Roney, P.; Sichta, P.; Tindall, K.

    1997-01-01

    The design and construction phase for the National Spherical Torus Experiment (NSTX) is under way at the Princeton Plasma Physics Laboratory (PPPL). Operation is scheduled to begin on April 30, 1999. This paper describes the conceptual design for the NSTX Central Instrumentation and Control (I and C) System. Major elements of the Central I and C System include the Process Control System, Plasma Control System, Network System, Data Acquisition System, and Synchronization System to support the NSTX experimental device

  9. Design of virtual three-dimensional instruments for sound control

    Science.gov (United States)

    Mulder, Axel Gezienus Elith

    An environment for designing virtual instruments with 3D geometry has been prototyped and applied to real-time sound control and design. It enables a sound artist, musical performer or composer to design an instrument according to preferred or required gestural and musical constraints instead of constraints based only on physical laws as they apply to an instrument with a particular geometry. Sounds can be created, edited or performed in real-time by changing parameters like position, orientation and shape of a virtual 3D input device. The virtual instrument can only be perceived through a visualization and acoustic representation, or sonification, of the control surface. No haptic representation is available. This environment was implemented using CyberGloves, Polhemus sensors, an SGI Onyx and by extending a real- time, visual programming language called Max/FTS, which was originally designed for sound synthesis. The extension involves software objects that interface the sensors and software objects that compute human movement and virtual object features. Two pilot studies have been performed, involving virtual input devices with the behaviours of a rubber balloon and a rubber sheet for the control of sound spatialization and timbre parameters. Both manipulation and sonification methods affect the naturalness of the interaction. Informal evaluation showed that a sonification inspired by the physical world appears natural and effective. More research is required for a natural sonification of virtual input device features such as shape, taking into account possible co- articulation of these features. While both hands can be used for manipulation, left-hand-only interaction with a virtual instrument may be a useful replacement for and extension of the standard keyboard modulation wheel. More research is needed to identify and apply manipulation pragmatics and movement features, and to investigate how they are co-articulated, in the mapping of virtual object

  10. Safety Evaluation of Kartini Reactor Based on Instrumentation System Design

    International Nuclear Information System (INIS)

    Tjipta Suhaemi; Djen Djen Dj; Itjeu K; Johnny S; Setyono

    2003-01-01

    The safety of Kartini reactor has been evaluated based on instrumentation system aspect. The Kartini reactor is designed by BATAN. Design power of the reactor is 250 kW, but it is currently operated at 100 kW. Instrumentation and control system function is to monitor and control the reactor operation. Instrumentation and control system consists of safety system, start-up and automatic power control, and process information system. The linear power channel and logarithmic power channel are used for measuring power. There are 3 types of control rod for controlling the power, i.e. safety rod, shim rod, and regulating rod. The trip and interlock system are used for safety. There are instrumentation equipment used for measuring radiation exposure, flow rate, temperature and conductivity of fluid The system of Kartini reactor has been developed by introducing a process information system, start-up system, and automatic power control. It is concluded that the instrumentation of Kartini reactor has followed the requirement and standard of IAEA. (author)

  11. Design and Implementation of Data Collection Instruments for Neonatology Research

    Directory of Open Access Journals (Sweden)

    Monica G. HĂŞMĂŞANU

    2014-12-01

    Full Text Available im: The aim of our research was to design and implement data collection instruments to be use in context of an observational prospective clinical study with follow-up conducted on new born with intrauterine growth restriction. Methods: The structure of the data collection forms (paper based and electronic based was first identified and for each variable the best type to accomplish the research aim was established. The code for categorical variables has also been decided as well as the units of measurements for quantitative variables. In respect of good practice, a set of confounding factors (as gender, date of birth, etc. have also been identified and integrated in data collection instruments. Data-entry validation rules were implemented for each variable to reduce data input errors when the electronic data collection instrument was created. Results: Two data collection instruments have been developed and successfully implemented: a paper-based form and an electronic data collection instrument. The developed forms included demographics, neonatal complications (as hypoglycemia, hypocalcemia, etc., biochemical data at birth and follow-up, immunological data, as well as basal and follow-up echocardiographic data. Data-entry validation criteria have been implemented in electronic data collection instrument to assure validity and precision when paper-based data are translated in electronic form. Furthermore, to assure subject’s confidentiality a careful attention was given to HIPPA identifiers when electronic data collection instrument was developed. Conclusion: Data collection instruments were successfully developed and implemented as an a priori step in a clinical research for assisting data collection and management in a case of an observational prospective study with follow-up visits.

  12. Remote sensing technology research and instrumentation platform design

    Science.gov (United States)

    1992-01-01

    An instrumented pallet concept and definition of an aircraft with performance and payload capability to meet NASA's airborne turbulent flux measurement needs for advanced multiple global climate research and field experiments is presented. The report addresses airborne measurement requirements for general circulation model sub-scale parameterization research, specifies instrumentation capable of making these measurements, and describes a preliminary support pallet design. Also, a review of aircraft types and a recommendation of a manned and an unmanned aircraft capable of meeting flux parameterization research needs is given.

  13. ASIC and HMC designs for portable nuclear instruments

    International Nuclear Information System (INIS)

    Chandratre, V.B.

    2005-01-01

    This paper describes the seed activity done so far for realizing the goal of compact portable nuclear instruments and related instrumentation that can be designed, developed and manufactured without external constraints. This important activity requires critical components to be made in the country by tapping and gearing the established industrial units for this activity. A good deal of ground work has been carried out over a period of time in setting up IC design facility and CAD-FAB interface. There has been a close interaction with the production and semiconductor facilities to design and develop ASIC, hybrids, display devices, detectors/sensors etc. Efforts are also undertaken to develop the critical technologies that are required to fulfill the requirement. A status report on various technologies, ASIC, hybrids and their application development done in the face of out-standing challenges is being presented here. (author)

  14. Self-reported cardiorespiratory fitness

    DEFF Research Database (Denmark)

    Holtermann, Andreas; Marott, Jacob Louis; Gyntelberg, Finn

    2015-01-01

    BACKGROUND: The predictive value and improved risk classification of self-reported cardiorespiratory fitness (SRCF), when added to traditional risk factors on cardiovascular disease (CVD) and longevity, are unknown. METHODS AND RESULTS: A total of 3843 males and 5093 females from the Copenhagen...

  15. Parents with Psychosis: A Pilot Study Examining Self-Report Measures Related to Family Functioning.

    Science.gov (United States)

    Plant, Karen; Byrne, Linda; Barkla, Joanne; McLean, Duncan; Hearle, Jenny; McGrath, John

    2002-01-01

    Examines the utility of various self-report instruments related to family functioning in families where a parent has a psychotic disorder, and explores associations between these instruments and symptoms in the parent. There were significant associations between objective measures of negative symptoms and self-report scores related to problems in…

  16. Design of an intelligent flight instrumentation unit using embedded RTOS

    Science.gov (United States)

    Estrada-Marmolejo, R.; García-Torales, G.; Torres-Ortega, H. H.; Flores, J. L.

    2011-09-01

    Micro Unmanned Aerial Vehicles (MUAV) must calculate its spatial position to control the flight dynamics, which is done by Inertial Measurement Units (IMUs). MEMS Inertial sensors have made possible to reduce the size and power consumption of such units. Commonly the flight instrumentation operates independently of the main processor. This work presents an instrumentation block design, which reduces size and power consumption of the complete system of a MUAV. This is done by coupling the inertial sensors to the main processor without considering any intermediate level of processing aside. Using Real Time Operating Systems (RTOS) reduces the number of intermediate components, increasing MUAV reliability. One advantage is the possibility to control several different sensors with a single communication bus. This feature of the MEMS sensors makes a smaller and less complex MUAV design possible.

  17. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  18. Thermal architecture design tests for the Planck/HFI instrument

    Energy Technology Data Exchange (ETDEWEB)

    Piat, M.; Leriche, B.; Torre, J.-P.; Lamarre, J.-M.; Benoit, A.; Crussaire, J.-P

    2000-04-07

    The ESA satellite project Planck is designed to survey the sky at sub-millimetre and millimetre wavelengths in a drift scan mode. The High-Frequency Instrument (HFI) will use 48 bolometers cooled to 100 mK by a dilution cooler. In this paper, we describe how the scan strategy leads to requirements on the 0.1 K stage temperature stability and how a combination of a passive and an active system can be used to approach this specification.

  19. Design of autotrack detecting instrument for solar UV radiation

    Science.gov (United States)

    Xia, Jiangtao; Mao, Xiaoli; Zhao, Jing

    2009-11-01

    In order to autotrack the object and detect the solar UV index, a reliable real-time high-precise instrument is proposed in this paper. This instrument involves two subsystems: the autotrack and detecting modules. The autotrack module consists of four-quadrant photo detector, multi-channel signal processing circuit and precise stepping system. The detecting module designed for dada measurement and acquisition is made up of the ultraviolet sensor UV460 and high precision A/D converter MAX1162. The key component of the entire instrument is ultralow-power microprocessor MSP430 which is used for entire system controlling and data processing. The lower system of autotracking and measurement is communicated with upper PC computer by RS232 module. In the experiment, the tracking precision of two-dimensional motion revolving stage is calibrated to be less than 0.05°. Experimental results indicate that the system designed could realize the precise autotracking and detecting function well, and the measure precision of system has reached the desirable target.

  20. Design and fabrication of non-instrumented capsule

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility.

  1. Design and fabrication of non-instrumented capsule

    International Nuclear Information System (INIS)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility

  2. Design of a digital and self-reported food frequency questionnaire to estimate food consumption in adolescents and young adults: birth cohorts at Pelotas, Rio Grande do Sul, Brazil.

    Science.gov (United States)

    Schneider, Bruna Celestino; Motta, Janaína Vieira Dos Santos; Muniz, Ludmila Correa; Bielemann, Renata Moraes; Madruga, Samanta Winck; Orlandi, Silvana Paiva; Gigante, Denise Petrucci; Assunção, Maria Cecília Formoso

    2016-01-01

    Methodological paper aiming to describe the development of a digital and self-reported food frequency questionnaire (FFQ), created to the 1982 and 1993 Pelotas Birth Cohorts. The instrument was created based on FFQs previously applied to subjects belonging to both cohorts in the 2004 and 2008 follow-ups. The FFQ was developed including 88 foods and/or meals where frequencies were clustered from a minimum of never or once/month to a maximum of greater than or equal to 5 times/day. The closed options related to portions were based on a 24-hour recall previously asked to a subsample from the 1993 cohort. Three options for portions were created: equal to, less than or greater than. Equal to portion was described based on the 50 percentile of each food consumed reported in a 24-hour recall. Photographs of portions related to the 50 percentile for each food were also included in the software. This digital FFQ included food and meals based on the needs of current researches. The layout of the software was attractive to the staff members as well as to the cohort members. The responding time was 12 minutes and the software allowed several individuals to use it at the same time. Moreover, this instrument dismissed interviewers and double data entry. It is recommended the use of the same strategy in other studies, adapted to different contexts and situations.

  3. Text mining a self-report back-translation.

    Science.gov (United States)

    Blanch, Angel; Aluja, Anton

    2016-06-01

    There are several recommendations about the routine to undertake when back translating self-report instruments in cross-cultural research. However, text mining methods have been generally ignored within this field. This work describes a text mining innovative application useful to adapt a personality questionnaire to 12 different languages. The method is divided in 3 different stages, a descriptive analysis of the available back-translated instrument versions, a dissimilarity assessment between the source language instrument and the 12 back-translations, and an item assessment of item meaning equivalence. The suggested method contributes to improve the back-translation process of self-report instruments for cross-cultural research in 2 significant intertwined ways. First, it defines a systematic approach to the back translation issue, allowing for a more orderly and informed evaluation concerning the equivalence of different versions of the same instrument in different languages. Second, it provides more accurate instrument back-translations, which has direct implications for the reliability and validity of the instrument's test scores when used in different cultures/languages. In addition, this procedure can be extended to the back-translation of self-reports measuring psychological constructs in clinical assessment. Future research works could refine the suggested methodology and use additional available text mining tools. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  4. VIMOS Instrument Control Software Design: an Object Oriented Approach

    Science.gov (United States)

    Brau-Nogué, Sylvie; Lucuix, Christian

    2002-12-01

    The Franco-Italian VIMOS instrument is a VIsible imaging Multi-Object Spectrograph with outstanding multiplex capabilities, allowing to take spectra of more than 800 objects simultaneously, or integral field spectroscopy mode in a 54x54 arcsec area. VIMOS is being installed at the Nasmyth focus of the third Unit Telescope of the European Southern Observatory Very Large Telescope (VLT) at Mount Paranal in Chile. This paper will describe the analysis, the design and the implementation of the VIMOS Instrument Control System, using UML notation. Our Control group followed an Object Oriented software process while keeping in mind the ESO VLT standard control concepts. At ESO VLT a complete software library is available. Rather than applying waterfall lifecycle, ICS project used iterative development, a lifecycle consisting of several iterations. Each iteration consisted in : capture and evaluate the requirements, visual modeling for analysis and design, implementation, test, and deployment. Depending of the project phases, iterations focused more or less on specific activity. The result is an object model (the design model), including use-case realizations. An implementation view and a deployment view complement this product. An extract of VIMOS ICS UML model will be presented and some implementation, integration and test issues will be discussed.

  5. Experimental design and quality assurance: in situ fluorescence instrumentation

    Science.gov (United States)

    Conmy, Robyn N.; Del Castillo, Carlos E.; Downing, Bryan D.; Chen, Robert F.

    2014-01-01

    Both instrument design and capabilities of fluorescence spectroscopy have greatly advanced over the last several decades. Advancements include solid-state excitation sources, integration of fiber optic technology, highly sensitive multichannel detectors, rapid-scan monochromators, sensitive spectral correction techniques, and improve data manipulation software (Christian et al., 1981, Lochmuller and Saavedra, 1986; Cabniss and Shuman, 1987; Lakowicz, 2006; Hudson et al., 2007). The cumulative effect of these improvements have pushed the limits and expanded the application of fluorescence techniques to numerous scientific research fields. One of the more powerful advancements is the ability to obtain in situ fluorescence measurements of natural waters (Moore, 1994). The development of submersible fluorescence instruments has been made possible by component miniaturization and power reduction including advances in light sources technologies (light-emitting diodes, xenon lamps, ultraviolet [UV] lasers) and the compatible integration of new optical instruments with various sampling platforms (Twardowski et at., 2005 and references therein). The development of robust field sensors skirt the need for cumbersome and or time-consuming filtration techniques, the potential artifacts associated with sample storage, and coarse sampling designs by increasing spatiotemporal resolution (Chen, 1999; Robinson and Glenn, 1999). The ability to obtain rapid, high-quality, highly sensitive measurements over steep gradients has revolutionized investigations of dissolved organic matter (DOM) optical properties, thereby enabling researchers to address novel biogeochemical questions regarding colored or chromophoric DOM (CDOM). This chapter is dedicated to the origin, design, calibration, and use of in situ field fluorometers. It will serve as a review of considerations to be accounted for during the operation of fluorescence field sensors and call attention to areas of concern when making

  6. Sentinel-5 instrument: status of design, performance, and development

    Science.gov (United States)

    Gühne, T.; Keim, C.; Bartsch, P.; Weiß, S.; Melf, M.; Seefelder, W.

    2017-09-01

    The Sentinel-5 instrument is currently under development by a consortium led by Airbus Defence and Space in the frame of the European Union Copernicus program. It is a customer furnished item to the MetOp Second Generation satellite platform, which will provide operational meteorological data for the coming decades. Mission objective of the Sentinel-5 is to monitor the composition of the Earth atmosphere for Copernicus Atmosphere Services by taking measurements of trace gases and aerosols impacting air quality and climate with high resolution and daily global coverage. Therefore the Sentinel-5 provides five dispersive spectrometers covering the UV-VIS (270…500 nm), NIR (685 …773 nm) and SWIR (1590…1675 and 2305…2385 nm) spectral bands with resolutions <=1nm. Spatially the Sentinel-5 provides a 108° field of view with a ground sampling of 7.5 x 7 km2 at Nadir. The development program is post PDR and the build-up of the industrial team is finalised. We report on the instrument architecture and design derived from the driving requirements, the predicted instrument performance, and the general status of the program.

  7. Older drivers' attitudes about instrument cluster designs in vehicles.

    Science.gov (United States)

    Owsley, Cynthia; McGwin, Gerald; Seder, Thomas

    2011-11-01

    Little is known about older drivers' preferences and attitudes about instrumentation design in vehicles. Yet visual processing impairments are common among older adults and could impact their ability to interface with a vehicle's dashboard. The purpose of this study is to obtain information from them about this topic, using focus groups and content analysis methodology. A trained facilitator led 8 focus groups of older adults. Discussion was stimulated by an outline relevant to dashboard interfaces, audiotaped, and transcribed. Using multi-step content analysis, a trained coder placed comments into thematic categories and coded comments as positive, negative, or neutral in meaning. Comments were coded into these categories: gauges, knobs/switches, interior lighting, color, lettering, symbols, location, entertainment, GPS, cost, uniformity, and getting information. Comments on gauges and knobs/switches represented half the comments. Women made more comments about getting information; men made more comments about uniformity. Positive and negative comments were made in each category; individual differences in preferences were broad. The results of this study will be used to guide the design of a population-based survey of older drivers about instrument cluster format, which will also examine how their responses are related to their visual processing capabilities. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Design and installation of advanced computer safety related instrumentation

    International Nuclear Information System (INIS)

    Koch, S.; Andolina, K.; Ruether, J.

    1993-01-01

    The rapidly developing area of computer systems creates new opportunities for commercial utilities operating nuclear reactors to improve plant operation and efficiency. Two of the main obstacles to utilizing the new technology in safety-related applications is the current policy of the licensing agencies and the fear of decision making managers to introduce new technologies. Once these obstacles are overcome, advanced diagnostic systems, CRT-based displays, and advanced communication channels can improve plant operation considerably. The article discusses outstanding issues in the area of designing, qualifying, and licensing of computer-based instrumentation and control systems. The authors describe the experience gained in designing three safety-related systems, that include a Programmable Logic Controller (PLC) based Safeguard Load Sequencer for NSP Prairie Island, a digital Containment Isolation monitoring system for TVA Browns Ferry, and a study that was conducted for EPRI/NSP regarding a PLC-based Reactor Protection system. This article presents the benefits to be gained in replacing existing, outdated equipment with new advanced instrumentation

  9. Analogue patients’ self-reported engagement and psychophysiological arousal in a video-vignettes design : Patients versus disease-naïve individuals

    NARCIS (Netherlands)

    Visser, L.N.C.; Tollenaar, M.S.; Bosch, J.A.; van Doornen, L.J.P.; de Haes, H.C.J.M.; Smets, E.M.A.

    2016-01-01

    Objectives The ecological validity of video-vignettes design investigating patient-provider communication hinges on the engagement of analogue patients (APs) with the vignette. The present study aimed to compare engagement in two commonly utilized groups of APs, patients and disease-naïve

  10. Analogue patients' self-reported engagement and psychophysiological arousal in a video-vignettes design: Patients versus disease-naïve individuals

    NARCIS (Netherlands)

    Visser, Leonie N. C.; Tollenaar, Marieke S.; Bosch, Jos A.; van Doornen, Lorenz J. P.; de Haes, Hanneke C. J. M.; Smets, Ellen M. A.

    2016-01-01

    The ecological validity of video-vignettes design investigating patient-provider communication hinges on the engagement of analogue patients (APs) with the vignette. The present study aimed to compare engagement in two commonly utilized groups of APs, patients and disease-naïve individuals.

  11. Matter in Extreme Conditions Instrument - Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, R.F.; Boyce, R.M.; Haller, G.; Hastings, J.B.; Hays, G.; Lee, H.J.; /SLAC; Lee, R.W.; /LLNL, Livermore; Nagler, B.; /Rutherford; Scharfenstein, M.; Marsh, D.; White, W.E.; /SLAC

    2009-12-09

    The SLAC National Accelerator Laboratory (SLAC), in collaboration with Argonne National Laboratory (ANL), Lawrence Livermore National Laboratory (LLNL), and the University of California at Los Angeles (UCLA), is constructing a Free-Electron Laser (FEL) research facility. The FEL has already met its performance goals in the wavelength range 1.5 nm - 0.15 nm. This facility, the Linac Coherent Light Source (LCLS), utilizes the SLAC 2-Mile Linear Accelerator (linac) and will produce sub-picosecond pulses of short wavelength X-rays with very high peak brightness and almost complete transverse coherence. The final one-third of the SLAC linac is used as the source of electrons for the LCLS. The high energy electrons are transported across the SLAC Research Yard, into a tunnel which houses a long undulator. In passing through the undulator, the electrons are bunched by the force of their own synchrotron radiation and produce an intense, monochromatic, spatially coherent beam of X-rays. By varying the electron energy, the FEL X-ray wavelength is tunable from 1.5 nm to 0.15 nm. The LCLS includes two experimental halls as well as X-ray optics and infrastructure necessary to create a facility that can be developed for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of designing and constructing an X-ray instrument in order to exploit the unique scientific capability of LCLS by creating extreme conditions and study the behavior of plasma under those controlled conditions. This instrument will address the Office of Science, Fusion Energy Sciences, mission objective related to study of Plasma and Warm Dense Matter as described in the report titled LCLS, the First Experiments, prepared by the LCLS Scientific Advisory Committee (SAC) in September 2000. The technical objective of the LCLS Matter in Extreme Conditions (MEC) Instrument project is

  12. Self-Report Measures of Parent-Adolescent Attachment and Separation-Individuation: A Selective Review.

    Science.gov (United States)

    Lopez, Frederick G.; Gover, Mark R.

    1993-01-01

    Reviews and critiques three self-report measures of parent-adolescent attachment (Parental Bonding Instrument, Parental Attachment Questionnaire, Inventory of Parent and Peer Attachment) and three self-report measures of parent-adolescent separation-individuation (Psychological Separation Inventory, Personal Authority in the Family System…

  13. Teachers' Self-Reported Pedagogical Practices toward Socially Inhibited, Hyperactive, and Average Children

    Science.gov (United States)

    Thijs, Jochem T.; Koomen, Helma M. Y.; Van Der Leij, Aryan

    2006-01-01

    This study examined teachers' self-reported pedagogical practices toward socially inhibited, hyperactive, and average kindergartners. A self-report instrument was developed and examined in three samples of kindergartners and their teachers. Principal components analyses were conducted in four datasets pertaining to 1 child per teacher. Two…

  14. Validating the Factor Structure of the Self-Report Psychopathy Scale in a Community Sample

    Science.gov (United States)

    Mahmut, Mehmet K.; Menictas, Con; Stevenson, Richard J.; Homewood, Judi

    2011-01-01

    Currently, there is no standard self-report measure of psychopathy in community-dwelling samples that parallels the most commonly used measure of psychopathy in forensic and clinical samples, the Psychopathy Checklist. A promising instrument is the Self-Report Psychopathy scale (SRP), which was derived from the original version the Psychopathy…

  15. Embedded design based virtual instrument program for positron beam automation

    International Nuclear Information System (INIS)

    Jayapandian, J.; Gururaj, K.; Abhaya, S.; Parimala, J.; Amarendra, G.

    2008-01-01

    Automation of positron beam experiment with a single chip embedded design using a programmable system on chip (PSoC) which provides easy interfacing of the high-voltage DC power supply is reported. Virtual Instrument (VI) control program written in Visual Basic 6.0 ensures the following functions (i) adjusting of sample high voltage by interacting with the programmed PSoC hardware, (ii) control of personal computer (PC) based multi channel analyzer (MCA) card for energy spectroscopy, (iii) analysis of the obtained spectrum to extract the relevant line shape parameters, (iv) plotting of relevant parameters and (v) saving the file in the appropriate format. The present study highlights the hardware features of the PSoC hardware module as well as the control of MCA and other units through programming in Visual Basic

  16. USE OF LEAN PRODUCTION INSTRUMENTS IN DESIGNING THE EDUCATIONAL PROCESS

    Directory of Open Access Journals (Sweden)

    Elietta P. Burnasheva

    2016-03-01

    Full Text Available Introduction: the concept of lean production seeks not a reduction of costs but complete elimination of losses that do not bring added value to the product or service. In any system, in all processes – from production and assembly, to hospitality, education, health, transport and social services – there are hidden losses. Teaching itself is a kind of production process in which a certain “product” (student acquires the added value (knowledge and skills, that is why it has become topical in educational institution to establish the working group on introduction of lean production into the learning process. The article presents the factors that are to be taken into account while designing the educational process based on the lean production principles. Materials and Methods: methods of analysis of existing system of vocational training in higher school, monitoring of the results of educational practice, modeling and experimental work in the process of analytical work were used. Results: important direction for eliminating losses in the educational process is the development of the interlinked curricula, allowing to avoid repeated study of a number of didactic units in the organization of continuous training in the system “Vocational education – Higher education”. In order to eliminate the possibility of incompetent graduate one should focus on the organisation of objective final control. Losses in education are caused by to the mismatch between labour market demand and the spectrum of areas of training in educational institutions. Discussion and Conclusions: the lean production possibilities are defined as instrumental in ensuring the organisation of “the process of lean learning”: by applying some lean production instruments such as the designing of the educational process, preventing of “faulty work” while training students, the attuning of the training system to employers’ requests, the visualisation of the education

  17. Upgrading instrumentation and control in nuclear power plants. Design criteria

    International Nuclear Information System (INIS)

    Rodriguez Rodriguez, M.C.; Alvarez Menendez, A.

    1997-01-01

    The use of programmed digital technology in Protection, Control, Monitoring and Information Systems in new generation nuclear power plants, or the use of this technology to replace or upgrade existing systems based on wired analog instrumentation and electromechanical relays, has led to new international standards which establish new design requirements or adapt existing requirements to this technology. Additionally, both regulatory organisations and the industry are discussing the reliability of this technology, regarding common mode failures that may occur in redundant protection channels, due to the use of equipment and software with the same characteristics. The first part of this paper addresses the most important aspects of new international standards regarding classification criteria for I and C systems, equipment and functions, depending on their importance to safety and the design criteria applicable to each category. Special attention is drawn to requirements concerning software quality assurance and the design of new control rooms. The paper then goes on to discuss the different technical solutions being implemented, using equipment and software diversification, in order to prevent the possibility of common mode failures affecting the protection function. (Author)

  18. Identifying Students Struggling in Courses by Analyzing Exam Grades, Self-reported Measures and Study Activities

    DEFF Research Database (Denmark)

    Christensen, Bianca Clavio; Bemman, Brian; Knoche, Hendrik

    2018-01-01

    . In this paper, we present a set of instrument`s designed to identify at-risk undergraduate students in a Problem-based Learning (PBL) university, using an introductory programming course between two campus locations as a case study. Collectively, these instruments form the basis of a proposed learning ecosystem...... in the prediction model. Results of a multiple linear regression model found several significant assessment predictors related to how often students attempted self-guided course assignments and their self-reported programming experience, among others.......Technical educations often experience poor student performance and consequently high rates of attrition. Providing students with early feedback on their learning progress can assist students in self-study activities or in their decision-making process regarding a change in educational direction...

  19. Design of the Local Instrument for KSTAR Gravity Support

    International Nuclear Information System (INIS)

    Her, N. I.; Kim, H. K.; Kim, Y. O.; Sa, J. W.; Kim, G. H.; Kim, K. M.; Park, Y. M.; Hong, G. H.; Choi, C. H.; Bak, J. S.

    2005-01-01

    The gravity support installed between the lower toroidal field (TF) coil cooled by 4.5 K supercritical helium and the cryostat base is the main support structure for the Korea Superconducting Tokamak Advanced Research (KSTAR) superconducting magnet system. This structure should be flexible to absorb thermal shrink of the magnet and also should be rigid to support the magnet weight and the plasma disruptions loads. The gravity support was designed with stainless steel 316LN and Carbon fiber Reinforced Plastics (CFRP) that has low thermal conductivity and high structural strength at low temperature. The fabrication of the support has been completed after engineering design. The gravity support is composed of one toroidal ring and eight supporting posts as shown in Figure 1. The toroidal ring and post are cooled by 4.5 K supercritical helium and 77 K gaseous helium, respectively. The overall dimension of the post is 1 m height and 0.8 m width and depth, respectively. The post is composed of upper block, inner CFRP plate, lower block, flexible plate, thermal anchor block, outer CFRP plate, base block, and strengthen plate. Inner CFRP plate is connected to the upper and lower block using the pin. And the outer CFRP plate is connected to the thermal anchor block and the base block. Inner and outer CFRP plates consist of four and two 20 mm thin plates, respectively. Flexible plates consist of four 8 mm thin stainless steel plates to absorb the magnet shrinkage. These plates are assembled into the thermal anchor block and lower block. The fabrication of the gravity support initiated October 2002 has been completed in October 2003. The supporting post and toroidal ring were fabricated at shop individually and assembled at site. Various of static and dynamic loads will increase the stress level of the structure during the cool-down and plasma operation. After fabrication of the structure, we designed an instrumentation system to monitoring the structural safety. This system

  20. Design of instrument for monitoring nuclear radiation and baneful gas

    International Nuclear Information System (INIS)

    Xiong Jianping; Chen Jun; Zhu Wenkai

    2006-01-01

    Counters and ionization chambers are applied to sensors, and microprocessor based on ARM IP is applied to center controller in the instrument. It is achieved to monitor nuclear radiation and baneful gas in an instrument. The instrument is capable of LCD displaying, menu operating and speech alarming. (authors)

  1. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  2. Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists.

    Science.gov (United States)

    Moran, Robert W; Rushworth, Wendy M; Mason, Jesse

    2017-12-01

    Healthcare practitioner beliefs influence advice and management provided to patients with back pain. Several instruments measuring practitioner beliefs have been developed but psychometric properties for some have not been investigated. To investigate internal consistency, test-retest reliability and convergent validity of the Fear Avoidance Beliefs Tool (FABT), the Tampa Scale of Kinesiophobia for Health Care Providers (TSK-HC), the Back Pain Attitudes Questionnaire (Back-PAQ), and the Health Care Pain and Impairment Relationship Scale (HC-PAIRS). A secondary aim was to explore beliefs of New Zealand osteopaths and physiotherapists regarding low back pain. FABT, TSK-HC, Back-PAQ, and HC-PAIRS were administered twice, 14 days apart. Data from 91 osteopaths and 35 physiotherapists were analysed. The FABT, TSK-HC and Back-PAQ each demonstrated excellent internal consistency, (Cronbach's α = 0.92, 0.91, and 0.91 respectively), and excellent test-retest reliability (lower limit of 95% CI for intraclass correlation coefficient >0.75). Correlations between instruments (Pearson's r = 0.51 to 0.77, p  0.47) for mean differences in scores, for all instruments, between professions. This study found excellent internal consistency, test-retest reliability and good convergent validity for the FABT, TSK-HC, and Back-PAQ. Previously reported internal consistency, test-retest and convergent validity of the HC-PAIRS were confirmed, and test-retest reliability was excellent. There were significant scoring differences on each instrument between professions, and while both groups demonstrated fear avoidant beliefs, physiotherapist respondent scores indicated that as a group, they held fewer fear-avoidant beliefs than osteopath respondents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  4. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  5. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  6. Hardware design for new instrumentation and control system of RTP

    International Nuclear Information System (INIS)

    Mohd Idris Taib; Izhar Abu Hussin; Zareen Khan Abdul Jalil Khan; Mohd Dzul Aiman Aslan; Mohd Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha; Mohd Sabri Minhat

    2010-01-01

    The design for New Instrumentation and Control system of RTP are proposed. Physical system is modular-based, comprise of several cabinets such as Reactor Protection System 1 and 2, Control Console, Information Console 1 and 2 as well as Communication Console. Reactor Protection System automatically will shut-down reactor whenever safety limit setting was approach. Control console is where the reactor operator actually controls the reactor with control the movement of control rods. Information Consoles using Liquid Crystal Display to monitor the reactor parameters. Communication Console is where the communication tools such as telephone and intercom are located. This new system will incorporated analog, digital and computer-based. Reactor Protection System will use all analog system. Reactor Control System and Reactor Monitoring System will use analog as well as computer-based system. Wide-range channel will use digital signal processor as a main component. Controlling control rod movement is using control rod button via microprocessor-based control rod controller. Automatic Flux Controller is using embedded computer for flexibility of programming. Data Acquisition System is using Programmable Logic Controller and Industrial Computer. The main software for this system will be developed using WinCC software. (author)

  7. Influence of instrument design on neutron lifetime measurements

    International Nuclear Information System (INIS)

    Youmans, A.H.; Hopkinson, E.C.

    1975-01-01

    Commercially available logging services provide a measurement of the lifetime of thermal neutrons in formations adjacent to a borehole. This lifetime provides a measure of the macroscopic thermal neutron-capture cross-section Σ of the formation, which in turn is functionally related to the abundance and constituency of the rock matrix and contained fluids. Because the measurement is extremely sensitive to an abundance of trace elements like boron and gadolinium, it is very difficult to find rock formations with an accurately known value of Σ, which is required for the accuracy of the measuring system to be experimentally tested. Various theoretical studies published suggest that errors in the determination of Σ may occur because of the influence of borehole parameters and the effects of neutron diffusion. Experimental results are reported that demonstrate that the design of the instrument is crucial to the validity of any theoretical treatment of the subject. The influence of neutron diffusion and borehole effects can be overcome by optimal selection of spacing and shielding parameters

  8. Six-Degree-of-Freedom Sensor Fish Design and Instrumentation

    Directory of Open Access Journals (Sweden)

    Marshall C. Richmond

    2007-11-01

    Full Text Available Fish passing through dams may be injured or killed despite advances in turbinedesign, project operations and other fish bypass systems. The six-degree-of-freedom (6DOFSensor Fish device is an autonomous sensor package that characterizes the physical conditionsand physical stresses to which fish are exposed when they pass through complex hydraulicenvironments. It has been used to identify the locations and operations where conditions aresevere enough to injure or kill fish. During the design process, a set of governing equationsof motion for the Sensor Fish was derived and simulated to understand the design implica-tions of instrument selection and placement within the body of the device. The Sensor Fishpackage includes three rotation sensors, three acceleration sensors, a pressure sensor, and atemperature sensor with a sampling frequency of 2,000 Hz. Its housing is constructed of clearpolycarbonate plastic. It is 24.5 mm in diameter and 90 mm in length and weighs about 43 g,similar to the size and density of a yearling salmon smolt. The accuracy of the pressure sensorwas determined to be within 0.2 psi. In laboratory acceptance tests, the relative errors of boththe linear acceleration and angular velocity measurements were determined to be less than5%. An exposure is defined as a significant event when the acceleration reaches predefinedthresholds. Based on the different characteristic of acceleration and rotation velocities, theexposure event is categorized as either a collision between the Sensor Fish and a solid struc-ture or shear caused by turbulence. Since its development in 2005, the 6DOF Sensor Fish hasbeen deployed successfully at many major dams in the United States.

  9. Accuracy of self-reported family history is strongly influenced by the accuracy of self-reported personal health status of relatives

    NARCIS (Netherlands)

    Janssens, A.C.J.W.; Henneman, L.; Detmar, S.B.; Khoury, M.J.; Steyerberg, E.W.; Eijkemans, M.J.C.; Mushkudiani, N.; Oostra, B.A.; Duijn, C.M. van; MacKenbach, J.P.

    2012-01-01

    Objective: We investigated the accuracy of self-reported family history for diabetes, hypertension, and overweight against two reference standards: family history based on physician-assessed health status of relatives and on self-reported personal health status of relatives. Study Design and

  10. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  11. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  12. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  13. Cost-effective design of economic instruments in nutrition policy

    Directory of Open Access Journals (Sweden)

    Smed Sinne

    2007-04-01

    Full Text Available Abstract This paper addresses the potential for using economic regulation, e.g. taxes or subsidies, as instruments to combat the increasing problems of inappropriate diets, leading to health problems such as obesity, diabetes 2, cardiovascular diseases etc. in most countries. Such policy measures may be considered as alternatives or supplements to other regulation instruments, including information campaigns, bans or enhancement of technological solutions to the problems of obesity or related diseases. 7 different food tax and subsidy instruments or combinations of instruments are analysed quantitatively. The analyses demonstrate that the average cost-effectiveness with regard to changing the intake of selected nutritional variables can be improved by 10–30 per cent if taxes/subsidies are targeted against these nutrients, compared with targeting selected food categories. Finally, the paper raises a range of issues, which need to be investigated further, before firm conclusions about the suitability of economic instruments in nutrition policy can be drawn.

  14. Self-report measure of financial exploitation of older adults.

    Science.gov (United States)

    Conrad, Kendon J; Iris, Madelyn; Ridings, John W; Langley, Kate; Wilber, Kathleen H

    2010-12-01

    this study was designed to improve the measurement of financial exploitation (FE) by testing psychometric properties of the older adult financial exploitation measure (OAFEM), a client self-report instrument. rasch item response theory and traditional validation approaches were used. Questionnaires were administered by 22 adult protective services investigators from 7 agencies in Illinois to 227 substantiated abuse clients. Analyses included tests for dimensionality, model fit, and additional construct validation. Results from the OAFEM were also compared with the substantiation decision of abuse and with investigators' assessments of FE using a staff report version. Hypotheses were generated to test hypothesized relationships. the OAFEM, including the original 79-, 54-, and 30-item measures, met stringent Rasch analysis fit and unidimensionality criteria and had high internal consistency and item reliability. The validation results were supportive, while leading to reconsideration of aspects of the hypothesized theoretical hierarchy. Thresholds were suggested to demonstrate levels of severity. the measure is now available to aid in the assessment of FE of older adults by both clinicians and researchers. Theoretical refinements developed using the empirically generated item hierarchy may help to improve assessment and intervention.

  15. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  16. Validation of self-reported erythema

    DEFF Research Database (Denmark)

    Petersen, B; Thieden, E; Lerche, C M

    2013-01-01

    Most epidemiological data of sunburn related to skin cancer have come from self-reporting in diaries and questionnaires. We thought it important to validate the reliability of such data.......Most epidemiological data of sunburn related to skin cancer have come from self-reporting in diaries and questionnaires. We thought it important to validate the reliability of such data....

  17. Self-Report Measures of Family Competence.

    Science.gov (United States)

    Green, Robert G.

    1987-01-01

    Describes and compares two self-report measures of family competence: the Family Awareness Scales (FAS) (Green and Kolevzon, late 1970s) and the Self-Report Family Inventory (SFI) (Beavers, 1983). Discusses reliability and validity. Their focus on the "insider" (family member) is different from the traditional examination of family…

  18. International survey of self-reported medicine use among adolescents

    DEFF Research Database (Denmark)

    Hansen, Ebba H; Holstein, Bjørn E; Due, Pernille

    2003-01-01

    OBJECTIVE: To examine gender, age, and country variations in adolescents' self-reported medicine use. DESIGN: Cross-sectional school surveys of representative samples of 11- to 15-year-old girls and boys were used. The 1997/1998 Health Behaviour in School-aged Children study was referenced. A sta...

  19. Self-Report and Psychophysiological Responses to Fear Appeals

    Science.gov (United States)

    Ordonana, Juan R.; Gonzalez-Javier, Francisca; Espin-Lopez, Laura; Gomez-Amor, Jesus

    2009-01-01

    This study was designed to assess the relationship between self-report and psychophysiological responses to fear appeals and behavioral changes elicited by these. Ninety-two subjects watched one of four messages that varied in level of threat (high vs. low) and efficacy (high vs. low). Concomitantly, psychophysiological measures (heart rate and…

  20. Personality, Organizational Orientations and Self-Reported Learning Outcomes

    Science.gov (United States)

    Bamber, David; Castka, Pavel

    2006-01-01

    Purpose: To identify competencies connecting personality, organizational orientations and self-reported learning outcomes (as measured by concise Likert-type scales), for individuals who are learning for their organizations. Design/methodology/approach: Five concise factor scales were constructed to represent aspects of personality. Three further…

  1. Self-reported Attention Deficit and Hyperactivity Disorder symptoms ...

    African Journals Online (AJOL)

    Objective: To determine the prevalence of self-reported attention deficit and hyperactivity disorder (ADHD) symptoms among university students in Eldoret, Kenya. Design: A cross-sectional descriptive study of all students who gave consent to participate in the study. Setting: Moi University's Town Campus, comprising the ...

  2. Design of a TFT-LCD Based Digital Automobile Instrument

    Directory of Open Access Journals (Sweden)

    Yunsong Xu

    2014-01-01

    instrument and gives an introduction to the sampling circuits and interfaces related to these signals. Following this is the functional categorizing of the circuit modules, such as video buffer circuit, CAN bus interface circuit, and TFT-LCD drive circuit. Additionally, the external EEPROM stores information of the vehicle for history data query, and the external FLASH enables the display of high quality figures. On the whole, the accomplished automobile instrument meets the requirements of automobile instrument markets with its characters of low cost, favorable compatibility, friendly interfaces, and easy upgrading.

  3. GEO-CAPE Coastal Ecosystem Dynamics Imager (COEDI) Instrument Design

    Data.gov (United States)

    National Aeronautics and Space Administration — The primary goal of this study is to build a breadboard instrument and prove the functionality of the optical-mechanical assembly for the Coastal Ecosystem Dynamics...

  4. Instruments

    International Nuclear Information System (INIS)

    Buehrer, W.

    1996-01-01

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs

  5. Designing new guides and instruments using McStas

    CERN Document Server

    Farhi, E; Wildes, A R; Ghosh, R; Lefmann, K

    2002-01-01

    With the increasing complexity of modern neutron-scattering instruments, the need for powerful tools to optimize their geometry and physical performances (flux, resolution, divergence, etc.) has become essential. As the usual analytical methods reach their limit of validity in the description of fine effects, the use of Monte Carlo simulations, which can handle these latter, has become widespread. The McStas program was developed at Riso National Laboratory in order to provide neutron scattering instrument scientists with an efficient and flexible tool for building Monte Carlo simulations of guides, neutron optics and instruments. To date, the McStas package has been extensively used at the Institut Laue-Langevin, Grenoble, France, for various studies including cold and thermal guides with ballistic geometry, diffractometers, triple-axis, backscattering and time-of-flight spectrometers. In this paper, we present some simulation results concerning different guide geometries that may be used in the future at th...

  6. Designing new guides and instruments using McStas

    DEFF Research Database (Denmark)

    Farhi, E.; Hansen, T.; Wildes, A.

    2002-01-01

    of guides, neutron optics and instruments [1]. To date, the McStas package has been extensively used at the Institut Laue-Langevin, Grenoble, France, for various studies including cold and thermal guides with ballistic geometry, diffractometers, triple-axis, backscattering and time-of-flight spectrometers...

  7. Crime Self-Reporting Study: Phase 1

    National Research Council Canada - National Science Library

    Buck, Kelly

    2004-01-01

    The PERSEREC Crime Self-Reporting Study covers criminal record checks conducted in CY00 on 14,470 subjects of DoD security clearance investigations, including uniformed military, civilian, and contractor personnel...

  8. A New Instrument Design for Imaging Low Energy Neutral Atoms

    Science.gov (United States)

    Keller, John W.; Collier, Michael R.; Chornay, Dennis; Rozmarynowski, Paul; Getty, Stephanie; Cooper, John F.; Smith, Billy

    2007-01-01

    The MidSTAR-2 satellite, to be built at the US Naval Academy as a follow-on to the successful MidSTAR-1 satellite (http://web.ew.usna.edu/midstar/), will launch in 2011 and carry three Goddard Space Flight Center (GSFC) experiments developed under Goddard's Internal Research and Development (IRAD) program. One of these GSFC instruments, the Miniature Imager for Neutral Ionospheric atoms and Magnetospheric Electrons (MINI-ME) builds on the heritage of the Goddard-developed Low-Energy Neutral Atom (LENA) imager launched on the IMAGE spacecraft in 2000. MINI-ME features a Venetian-blind conversion surface assembly that improves both light rejection and conversion efficiency in a smaller and lighter package than LENA making this an highly effective instrument for viewing solar wind charge exchange with terrestrial and planetary exospheres. We will describe the MINI-ME prototyping effort and its science targets.

  9. Cost-effective design of economic instruments in nutrition policy

    DEFF Research Database (Denmark)

    Jensen, Jørgen Dejgård; Smed, Sinne

    2007-01-01

    This paper addresses the potential for using economic regulation, e.g. taxes or subsidies, as instruments to combat the increasing problems of inappropriate diets, leading to health problems such as obesity, diabetes 2, cardiovascular diseases etc. in most countries. Such policy measures may....... The analyses demonstrate that the average cost-effectiveness with regard to changing the intake of selected nutritional variables can be improved by 10–30 per cent if taxes/subsidies are targeted against these nutrients, compared with targeting selected food categories. Finally, the paper raises a range...... of issues, which need to be investigated further, before firm conclusions about the suitability of economic instruments in nutrition policy can be drawn....

  10. Design and Validation of an Instrumented Uneven Terrain Treadmill.

    Science.gov (United States)

    Voloshina, Alexandra S; Ferris, Daniel P

    2018-06-01

    Studying human and animal locomotion on an uneven terrain can be beneficial to basic science and applied studies for clinical and robotic applications. Traditional biomechanical analysis of human locomotion has often been limited to laboratory environments with flat, smooth runways and treadmills. The authors modified a regular exercise treadmill by attaching wooden blocks to the treadmill belt to yield an uneven locomotion surface. To ensure that these treadmill modifications facilitated biomechanical measurements, the authors compared ground reaction force data collected while a subject ran on the modified instrumented treadmill with a smooth surface with data collected using a conventional instrumented treadmill. Comparisons showed only minor differences. These results suggest that adding an uneven surface to a modified treadmill is a viable option for studying human or animal locomotion on an uneven terrain. Other types of surfaces (eg, compliant blocks) could be affixed in a similar manner for studies on other types of locomotion surfaces.

  11. Validation of self-reported cannabis dose and potency: an ecological study

    NARCIS (Netherlands)

    van der Pol, P.; Liebregts, N.; de Graaf, R.; Korf, D.J.; van den Brink, W.; van Laar, M.

    2013-01-01

    Aims To assess the reliability and validity of self-reported cannabis dose and potency measures. Design Cross-sectional study comparing self-reports with objective measures of amount of cannabis and delta-9-tetrahydrocannabinol (THC) concentration. Setting Ecological study with assessments at

  12. Design of the power sources for portable nuclear instruments

    International Nuclear Information System (INIS)

    Chen Wei; Fang Fang; Cui Yan; Cui Junliang; Zhou Wei

    2007-01-01

    How to charge for the portable equipments is always a topical subject aimed by people, the application of new type batteries and Battery Management brings great facility to people's life, the rechargeable battery for portable equipments is widely used in portable equipments, but the convenience of the charging power source is limited in special situation. This paper will discuss how to combining rechargeable battery with traditional alkaline batteries for charging the portable instruments. (authors)

  13. Assessing dependency using self-report and indirect measures: examining the significance of discrepancies.

    Science.gov (United States)

    Cogswell, Alex; Alloy, Lauren B; Karpinski, Andrew; Grant, David A

    2010-07-01

    The present study addressed convergence between self-report and indirect approaches to assessing dependency. We were moderately successful in validating an implicit measure, which was found to be reliable, orthogonal to 2 self-report instruments, and predictive of external criteria. This study also examined discrepancies between scores on self-report and implicit measures, and has implications for their significance. The possibility that discrepancies themselves are pathological was not supported, although discrepancies were associated with particular personality profiles. Finally, this study offered additional evidence for the relation between dependency and depressive symptomatology and identified implicit dependency as contributing unique variance in predicting past major depression.

  14. Body awareness: construct and self-report measures.

    Directory of Open Access Journals (Sweden)

    Wolf E Mehling

    Full Text Available Heightened body awareness can be adaptive and maladaptive. Improving body awareness has been suggested as an approach for treating patients with conditions such as chronic pain, obesity and post-traumatic stress disorder. We assessed the psychometric quality of selected self-report measures and examined their items for underlying definitions of the construct.PubMed, PsychINFO, HaPI, Embase, Digital Dissertations Database.Abstracts were screened; potentially relevant instruments were obtained and systematically reviewed. Instruments were excluded if they exclusively measured anxiety, covered emotions without related physical sensations, used observer ratings only, or were unobtainable. We restricted our study to the proprioceptive and interoceptive channels of body awareness. The psychometric properties of each scale were rated using a structured evaluation according to the method of McDowell. Following a working definition of the multi-dimensional construct, an inter-disciplinary team systematically examined the items of existing body awareness instruments, identified the dimensions queried and used an iterative qualitative process to refine the dimensions of the construct.From 1,825 abstracts, 39 instruments were screened. 12 were included for psychometric evaluation. Only two were rated as high standard for reliability, four for validity. Four domains of body awareness with 11 sub-domains emerged. Neither a single nor a compilation of several instruments covered all dimensions. Key domains that might potentially differentiate adaptive and maladaptive aspects of body awareness were missing in the reviewed instruments.Existing self-report instruments do not address important domains of the construct of body awareness, are unable to discern between adaptive and maladaptive aspects of body awareness, or exhibit other psychometric limitations. Restricting the construct to its proprio- and interoceptive channels, we explore the current understanding

  15. Instruments of Inquiry: Understanding the Nature and Role of Design Tools

    DEFF Research Database (Denmark)

    Dalsgaard, Peter

    2017-01-01

    Designers employ a range of tools in most design projects, yet there are few frameworks for understanding how and why they work. On the basis of a well-established school of thought, pragmatism, this paper contributes with a coherent conceptualisation of tools in design, which I label instruments...... of inquiry. This perspective underscores the crucial role that instruments play in design, and the ways in which they scaffold design creativity and exploration. In particular, it highlights that instruments not only augment our capabilities for carrying out intended actions, they also guide our perception...... and understanding of design problems and solutions. I present and discuss a framework consisting of five qualities of instruments of inquiry, which make them valuable in designerly inquiry: perception, conception, externalisation, knowing-through-action, and mediation....

  16. A Self-report of reading disabilities for adults: ATLAS

    Directory of Open Access Journals (Sweden)

    Almudena Giménez

    2015-01-01

    Full Text Available In this paper a self-report questionnaire on reading-writing difficulties for adults in Spanish (ATLAS is presented. Studies that use self-report questionnaires as a tool for screening of reading-writing difficulties in adults were reviewed. Two studies were carried out to determine the validity and reliability of ATLAS. The first study was aimed to select the critical items and to assess their reliability and their ability to discriminate. In the second study the assessment reported through the answers to the questionnaire was contrasted with the results of psychometric tests. Results showed that (a items were suitable descriptors for adult difficulties, (b there were significant correlations between self-report scores and reading measures, and (c the items discriminate between good and poor readers. The results of this study demonstrated that ATLAS is a sensitive tool to screen adults with reading difficulties. As a further advantage, ATLAS is an easy-to-use and time-saving instrument.

  17. Readability and comprehension of self-report binge eating measures.

    Science.gov (United States)

    Richards, Lauren K; McHugh, R Kathryn; Pratt, Elizabeth M; Thompson-Brenner, Heather

    2013-04-01

    The validity of self-report binge eating instruments among individuals with limited literacy is uncertain. This study aims to evaluate reading grade level and multiple domains of comprehension of 13 commonly used self-report assessments of binge eating for use in low-literacy populations. We evaluated self-report binge eating measures with respect to reading grade levels, measure length, formatting and linguistic problems. All measures were written at a reading grade level higher than is recommended for patient materials (above the 5th to 6th grade level), and contained several challenging elements related to comprehension. Correlational analyses suggested that readability and comprehension elements were distinct contributors to measure difficulty. Individuals with binge eating who have low levels of educational attainment or limited literacy are often underrepresented in measure validation studies. Validity of measures and accurate assessment of symptoms depend on an individual's ability to read and comprehend instructions and items, and these may be compromised in populations with lower levels of literacy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Proceedings of a workshop on methods for neutron scattering instrumentation design

    International Nuclear Information System (INIS)

    Hjelm, R.P.

    1997-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop. The international gathering of about 50 participants representing 15 national facilities, universities and corporations featured oral presentations, posters, discussions and demonstrations. Participants looked at a number of issues concerning neutron scattering instruments and the tools used in instrument design. Objectives included: (1) determining the needs of the neutron scattering community in instrument design computer code and information sharing to aid future instrument development, (2) providing for a means of training scientists in neutron scattering and neutron instrument techniques, and (3) facilitating the involvement of other scientists in determining the characteristics of new instruments that meet future scientific objectives, and (4) fostering international cooperation in meeting these needs. The scope of the meeting included: (1) a review of x-ray scattering instrument design tools, (2) a look at the present status of neutron scattering instrument design tools and models of neutron optical elements, and (3) discussions of the present and future needs of the neutron scattering community. Selected papers were abstracted separately for inclusion to the Energy Science and Technology Database

  19. Proceedings of a workshop on methods for neutron scattering instrumentation design

    Energy Technology Data Exchange (ETDEWEB)

    Hjelm, R.P. [ed.] [Los Alamos National Lab., NM (United States)

    1997-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop. The international gathering of about 50 participants representing 15 national facilities, universities and corporations featured oral presentations, posters, discussions and demonstrations. Participants looked at a number of issues concerning neutron scattering instruments and the tools used in instrument design. Objectives included: (1) determining the needs of the neutron scattering community in instrument design computer code and information sharing to aid future instrument development, (2) providing for a means of training scientists in neutron scattering and neutron instrument techniques, and (3) facilitating the involvement of other scientists in determining the characteristics of new instruments that meet future scientific objectives, and (4) fostering international cooperation in meeting these needs. The scope of the meeting included: (1) a review of x-ray scattering instrument design tools, (2) a look at the present status of neutron scattering instrument design tools and models of neutron optical elements, and (3) discussions of the present and future needs of the neutron scattering community. Selected papers were abstracted separately for inclusion to the Energy Science and Technology Database.

  20. Focal plane mechanical design of the NISP/Euclid instrument

    Science.gov (United States)

    Bonnefoi, Anne; Bon, William; Niclas, Mathieu; Solheim, Bjarte G. B.; Torvanger, Oyvind; Schistad, Robert; Foulon, Benjamin; Garcia, José; Vives, Sébastien

    2016-07-01

    Currently in phase C, the Euclid mission selected by ESA in the Cosmic Vision program is dedicated to understand dark energy and dark matter. NISP (standing for Near Infrared Spectro-Photometer) is one of the two instruments of the mission. NISP will combine a photometer and a spectrometer working in the near-IR (0.9-2 microns). Its detection subsystem (called NI-DS) is based on a mosaic of 16 IR detectors cooled down to 90K which are supported by a molybdenum plate. The front-end readout electronics (working at 130K) are supported by another structure in Aluminum. The NI-DS is mounted on the rest of the instrument thanks to a panel in Silicon Carbide (SiC). Finally an optical baffle in Titanium will prevent the rogue light to reach the detectors. On top of the complexity due to the wide range of temperatures and the various materials imposed at the interfaces; the NI-DS has also to incorporate an internal adjustment capability of the position of the focal plane in tip/tilt and focus. This article will present current status of the development of the detection system of NISP.

  1. Preliminary Analysis of Assessment Instrument Design to Reveal Science Generic Skill and Chemistry Literacy

    Science.gov (United States)

    Sumarni, Woro; Sudarmin; Supartono, Wiyanto

    2016-01-01

    The purpose of this research is to design assessment instrument to evaluate science generic skill (SGS) achievement and chemistry literacy in ethnoscience-integrated chemistry learning. The steps of tool designing refers to Plomp models including 1) Investigation Phase (Prelimenary Investigation); 2) Designing Phase (Design); 3)…

  2. Design and manufacturing of 05F-01K instrumented capsule for nuclear fuel irradiation in Hanaro

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, J. M.; Shin, Y. T.; Park, S. J. (and others)

    2007-07-15

    An instrumented capsule was developed to be able to measure fuel characteristics, such as fuel temperature, internal pressure of fuel rod, fuel pellet elongation, and neutron flux, etc., during the irradiation test of nuclear fuel in Hanaro. The instrumented capsule(02F-11K) for measuring and monitoring and monitoring fuel centerline temperature and neutron flux was designed and manufactured. It was successfully irradiated in the test hole OR5 of Hanaro from March 14, 2003 to June 1, 2003 (53.84 full power days at 24 MW). In the year of 2004, 3 test fuel rods and the instrumented capsule(03F-05K) were designed and manufactured to measure fuel centerline temperature, internal pressure of fuel rod, and fuel axial deformation during irradiation test. This capsule was irradiated in the test hole OR5 of Hanaro reactor from April 26, 2004 to October 1, 2004 (59.5 EFPD at 24 {approx} 30 MW). The six typed dual instrumented fuel rods, which allow for two characteristics to be measured simultaneously in one fuel rod, have been designed and manufactured to enhance the efficiency of the irradiation test using the instrumented fuel capsule. The 05F-01K instrumented fuel capsule was designed and manufactured for a design verification test of the three dual instrumented fuel rods. The irradiation test of the 05F-01K instrumented fuel capsule will be carried out at the OR5 vertical experimental hole of Hanaro.

  3. Neutron beam-line shield design for the protein crystallography instrument at the Lujan Center

    International Nuclear Information System (INIS)

    Russell, G.J.; Pitcher, E.J.; Muhrer, G.; Ferguson, P.D.

    2001-01-01

    We have developed a very useful methodology for calculating absolute total (neutron plus gamma-ray) dose equivalent rates for use in the design of neutron beam line shields at a spallation neutron source. We have applied this technique to the design of beam line shields for several new materials science instruments being built at the Manuel Lujan Jr. Neutron Scattering Center. These instruments have a variety of collimation systems and different beam line shielding issues. We show here some specific beam line shield designs for the Protein Crystallography Instrument. (author)

  4. Design and validation of an observational instrument for technical and tactical actions in beach volleyball

    Directory of Open Access Journals (Sweden)

    José Manuel Palao

    2015-06-01

    Full Text Available Technical and tactical actions determine performance in beach volleyball. This research develops and tests an instrument to monitor and evaluate the manner of execution and efficacy of the actions in beach volleyball. The purpose of this paper was to design and validate an observational instrument to analyze technical and tactical actions in beach volleyball. The instrument collects information regarding: a information about the match (context, b information about game situations, c information about technical situations (serve, reception, set, attack, block, and court defense in relation to player execution, role, manner of execution, execution zone, and efficacy, and d information about the result of the play (win-lose and way point is obtained. Instrument design and validation was done in seven stages: a review of literature and consultation of experts; b pilot observation and data analysis; c expert review of instrument (qualitative and quantitative evaluation; d observer training test; e expert review of instrument (content validity; f measurement of the ability of the instrument to discriminate the result of the set; and g measurement of the ability of the instrument to differentiate between competition age groups. The results show that the instrument allows for obtaining objective and valid information about the players and team from offensive and defensive technical and tactical actions, as well as indirectly from physical actions. The instrument can be used, in its entirety or partially, for researching and coaching purposes.

  5. Self-reported skin morbidity in Denmark

    DEFF Research Database (Denmark)

    Miller, Iben Marie; Zarchi, Kian; Ellervik, Christina

    2016-01-01

    Skin diseases are thought to be common in the general population. In 2004, a cross-sectional study in Norway, using a validated questionnaire for 18,770 individuals, revealed a high prevalence of skin diseases in the general population. To describe the prevalence of self-reported skin morbidities...... questionnaire. In total, 17.2% self-reported skin complaints. The most prominent self-reported skin complaint was itch with an overall prevalence of 6.5%. The skin morbidity most influenced by age was pimples. There was a uniform pattern showing fewer skin complaints with increasing education. Women reported...... skin morbidities more frequently than men. Participants in employment reported fewer skin morbidities compared to unemployed participants. Skin morbidities in Denmark are common, and the distribution of prevalence estimates in the Danish population parallel those of the Norwegian population, although...

  6. Self-Reported Knee Symptoms Assessed by KOOS Questionnaire in Downhill Runners (Skyrunners.

    Directory of Open Access Journals (Sweden)

    Giulio Sergio Roi

    Full Text Available The knee is the weight-bearing joint most commonly associated with sports injuries, and therefore is most at risk of developing degenerative changes, including osteoarthritis. Skyrunners can be considered to be at risk of developing symptoms of post-traumatic osteoarthritis due to downhill running.The aim of this study was to analyze the health of the knee joints of a large group of these athletes via a specific self-report questionnaire.This study was carried out by asking the participants of seven official Skyraces (22.4±3.1 km length; 1596±393 m elevation to fill out a questionnaire. Information regarding age, sex, downhill elevation (m during training and competitions over the last month, and history of previous knee injury was also collected before the participants filled out the Knee injury and Osteoarthritis Outcome Score (KOOS, which is a reliable and validated instrument designed to assess patients' opinions about their knees and associated problems that can result in post-traumatic osteoarthritis. Athletes were divided into six age groups (from 17 to 70 years and 12 groups based on the downhill gradient they had covered over the last month (from 1,000 to 40,000 m.Six hundred twenty-one questionnaires were collected from 45% of the participants in the seven races. Multivariate analysis revealed that self-reported KOOS scores were unrelated to age, sex and monthly downhill gradient. Only 74 (12% of the participants reported previous knee injuries. Significant differences in the five subscales of the KOOS were found between skyrunners with and without previous knee injuries (P<0.01.In the studied population, regular training for downhill running and participation in Skyraces could not be considered risk factors for subjective knee symptoms. Skyrunners with self-reported histories of knee injuries scored worse on all five subscales of the KOOS.

  7. A Workshop on Methods for Neutron Scattering Instrument Design. Introduction and Summary

    International Nuclear Information System (INIS)

    Hjelm, Rex P.

    1996-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop on ''Methods for Neutron Scattering Instrument Design'' September 23-25 at the E.O. Lawrence Berkeley National Laboratory. These proceedings are a collection of a portion of the invited and contributed presentations

  8. Designing Chemistry Practice Exams for Enhanced Benefits: An Instrument for Comparing Performance and Mental Effort Measures

    Science.gov (United States)

    Knaus, Karen J.; Murphy, Kristen L.; Holme, Thomas A.

    2009-01-01

    The design and use of a chemistry practice exam instrument that includes a measure for student mental effort is described in this paper. Use of such an instrument can beneficial to chemistry students and chemistry educators as well as chemical education researchers from both a content and cognitive science perspective. The method for calculating…

  9. Design of software platform based on linux operating system for γ-spectrometry instrument

    International Nuclear Information System (INIS)

    Hong Tianqi; Zhou Chen; Zhang Yongjin

    2008-01-01

    This paper described the design of γ-spectrometry instrument software platform based on s3c2410a processor with arm920t core, emphases are focused on analyzing the integrated application of embedded linux operating system, yaffs file system and qt/embedded GUI development library. It presented a new software platform in portable instrument for γ measurement. (authors)

  10. Instrumentation report 1: specification, design, calibration, and installation of instrumentation for an experimental, high-level, nuclear waste storage facility

    International Nuclear Information System (INIS)

    Brough, W.G.; Patrick, W.C.

    1982-01-01

    The Spent Fuel Test-Climax (SFT-C) is being conducted 420 m underground at the Nevada Test Site under the auspices of the US Department of Energy. The test facility houses 11 spent fuel assemblies from an operating commercial nuclear reactor and numerous other thermal sources used to simulate the near-field effects of a large repository. We developed a large-scale instrumentation plan to ensure that a sufficient quality and quantity of data were acquired during the three- to five-year test. These data help satisfy scientific, operational, and radiation safety objectives. Over 800 data channels are being scanned to measure temperature, electrical power, radiation, air flow, dew point, stress, displacement, and equipment operation status (on/off). This document details the criteria, design, specifications, installation, calibration, and current performance of the entire instrumentation package

  11. Genetic and environmental influences on self-reported reduced hearing in the old and oldest old

    DEFF Research Database (Denmark)

    Christensen, Kaare; Frederiksen, H; Hoffman, H J

    2001-01-01

    effects. Structural-equation analyses revealed a substantial heritability for self-reported reduced hearing of 40% (95% CI = 19-53%). The remaining variation could be attributed to individuals' nonfamilial environments. CONCLUSION: We found that genetic factors play an important role in self......-reported reduced hearing in both men and women age 70 and older. Because self-reports of reduced hearing involve misclassification, this estimate of the genetic influence on hearing disabilities is probably conservative. Hence, genetic and environmental factors play a substantial role in reduced hearing among......OBJECTIVES: The aim of the present twin study was to estimate the relative importance of genetic and environmental factors in variation in self-reported reduced hearing among the old and the oldest old. DESIGN: Self-reported hearing abilities of older twins assessed at intake interview...

  12. Opto-mechanical design for transmission optics in cryogenic space instrumentation

    Science.gov (United States)

    Kroes, Gabby; Venema, Lars; Navarro, Ramón

    2017-11-01

    NOVA is involved in the development and realization of various optical astronomical instruments for groundbased as well as space telescopes, with a focus on nearand mid-infrared instrumentation. NOVA has developed a suite of scientific instruments with cryogenic optics for the ESO VLT and VLTI instruments: VISIR, MIDI, the SPIFFI 2Kcamera for SINFONI, X-shooter and MATISSE. Other projects include the cryogenic optics for MIRI for the James Webb Space Telescope and several E-ELT instruments. Mounting optics is always a compromise between firmly fixing the optics and preventing stresses within the optics. The fixing should ensure mechanical stability and thus accurate positioning in various gravity orientations, temperature ranges, during launch, transport or earthquake. On the other hand, the fixings can induce deformations and sometimes birefringence in the optics and thus cause optical errors. Even cracking or breaking of the optics is a risk, especially when using brittle infrared optical materials at the cryogenic temperatures required in instruments for infrared astronomy, where differential expansion of various materials amounts easily to several millimeters per meter. Special kinematic mounts are therefore needed to ensure both accurate positioning and low stress. This paper concentrates on the opto-mechanical design of optics mountings, especially for large transmission optics in cryogenic circumstances in space instruments. It describes the development of temperature-invariant ("a-thermal") kinematic designs, their implementation in ground based instrumentation and ways to make them suitable for space instruments.

  13. Instrumental Genesis in GeoGebra Based Board Game Design

    DEFF Research Database (Denmark)

    Misfeldt, Morten

    2013-01-01

    In this paper I address the use of digital tools (GeoGebra) in open ended design activities, with primary school children. I present results from the research and development project “Creative Digital Mathematics”, which aims to use the pupil’s development of mathematical board games as a vehicle...... in their work with GeoGebra and how they relate their work with GeoGebra and mathematics to fellow pupils and real life situations. The results show that pupils’ consider development of board games as meaningful mathematical activity, and that they develop skills with GeoGebra, furthermore the pupils considers...... potential use of their board game by classmates in their design activities....

  14. The mechanical design and dynamic testing of the IBEX-H1 electrostatic analyzer spacecraft instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bernardin, John D [Los Alamos National Laboratory; Baca, Allen G [SNL

    2009-01-01

    This paper presents the mechanical design, fabrication and dynamic testing of an electrostatic analyzer spacecraft instrument. The functional and environmental requirements combined with limited spacecraft accommodations, resulted in complex component geometries, unique material selections, and difficult fabrication processes. The challenging aspects of the mechanical design and several of the more difficult production processes are discussed. In addition, the successes, failures, and lessons learned from acoustic and random vibration testing of a full-scale prototype instrument are presented.

  15. [Design and implementation of medical instrument standard information retrieval system based on APS.NET].

    Science.gov (United States)

    Yu, Kaijun

    2010-07-01

    This paper Analys the design goals of Medical Instrumentation standard information retrieval system. Based on the B /S structure,we established a medical instrumentation standard retrieval system with ASP.NET C # programming language, IIS f Web server, SQL Server 2000 database, in the. NET environment. The paper also Introduces the system structure, retrieval system modules, system development environment and detailed design of the system.

  16. Weight Misperception, Self-Reported Physical Fitness, Dieting and Some Psychological Variables as Risk Factors for Eating Disorders

    Directory of Open Access Journals (Sweden)

    Inmaculada Ruiz-Prieto

    2013-11-01

    Full Text Available The aims of the current study were to explore possible gender differences in weight misperception, self-reported physical fitness, and dieting, and to analyze the relationship between these variables and others, such as self-esteem, body appreciation, general mental health, and eating- and body image-related variables among adolescents. In addition, the specific risk for eating disorders was examined, as well as the possible clusters with respect to the risk status. The sample comprised 655 students, 313 females and 342 males, aged 16.22 ± 4.58. Different scales of perceived overweight, self-reported physical fitness and dieting together with the Body Mass Index (BMI were considered along with instruments such as the International Physical Activity Questionnaire (IPAQ, General Health Questionnaire (GHQ-28, Self-Esteem Scale (SES, Body Appreciation Scale (BAS and Eating Disorders Inventory-2 (EDI-2. Since some gender differences were found with respect to these adolescent groups, it is necessary to design prevention programs that not only focus on traditional factors such as BMI or body image, but also on elements like weight perception, self-reported fitness and nutritional education.

  17. What's in a Self-report?

    DEFF Research Database (Denmark)

    Larsen, Pernille Stemann; Andersen, Anne-Marie Nybo; Olsen, Else Marie

    2016-01-01

    of ED recorded in the health registers. Women with self-reported ED were comparable with women with hospital diagnosed ED on most reproductive and health characteristics, while they differed from women without ED concerning all characteristics studied. Our findings highlight that women with self...

  18. Self reported stressful life events and exacerbations in multiple sclerosis: prospective study

    NARCIS (Netherlands)

    D. Buljevac (Dragan); W.C.J. Hop (Wim); W. Reedeker; A.C.J.W. Janssens (Cécile); F.G.A. van der Meché (Frans); P.A. van Doorn (Pieter); R.Q. Hintzen (Rogier)

    2003-01-01

    textabstractOBJECTIVE: To study the relation between self reported stressful life events not related to multiple sclerosis and the occurrence of exacerbations in relapsing-remitting multiple sclerosis. DESIGN: Longitudinal, prospective cohort study. SETTING: Outpatient clinic of

  19. Self-report and long-term field measures of MP3 player use: how accurate is self-report?

    Science.gov (United States)

    Portnuff, C D F; Fligor, B J; Arehart, K H

    2013-02-01

    This study was designed to evaluate the usage patterns of portable listening device (PLD) listeners, and the relationships between self-report measures and long-term dosimetry measures of listening habits. This study used a descriptive correlational design. Participants (N = 52) were 18-29 year old men and women who completed surveys. A randomly assigned subset (N = 24) of participants had their listening monitored by dosimetry for one week. Median weekly noise doses reported and measured through dosimetry were low (9-93%), but 14.3% of participants reported exceeding a 100% noise dose weekly. When measured by dosimetry, 16.7% of participants exceeded a 100% noise dose weekly. The self-report question that best predicted the dosimetry-measured dose asked participants to report listening duration and usual listening level on a visual-analog scale. This study reports a novel dosimetry system that can provide accurate measures of PLD use over time. When not feasible, though, the self-report question described could provide a useful research or clinical tool to estimate exposure from PLD use. Among the participants in this study, a small but substantial percentage of PLD users incurred exposure from PLD use alone that increases their risk of music-induced hearing loss.

  20. Burnout syndrome among non-consultant hospital doctors in Ireland: relationship with self-reported patient care.

    Science.gov (United States)

    Sulaiman, Che Fatehah Che; Henn, Patrick; Smith, Simon; O'Tuathaigh, Colm M P

    2017-10-01

    Intensive workload and limited training opportunities for Irish non-consultant hospital doctors (NCHDs) has a negative effect on their health and well-being, and can result in burnout. Burnout affects physician performance and can lead to medical errors. This study examined the prevalence of burnout syndrome among Irish NCHDs and its association with self-reported medical error and poor quality of patient care. A cross-sectional quantitative survey-based design. All teaching hospitals affiliated with University College Cork. NCHDs of all grades and specialties. The following instruments were completed by all participants: Maslach Burnout Inventory-Human Service Survey (MBI-HSS), assessing three categories of burnout syndrome: Emotional exhaustion (EE), Personal Achievement (PA) and Depersonalization (DP); questions related to self-reported medical errors/poor patient care quality and socio-demographic information. Self-reported measures of burnout and poor quality of patient care. Prevalence of burnout among physicians (n = 265) was 26.4%. There was a significant gender difference for EE and DP, but none for PA. A positive weak correlation was observed between EE and DP with medical error or poor patient care. A negative association was reported between PA and medical error and reduced quality of patient care. Burnout is prevalent among NCHDs in Ireland. Burnout syndrome is associated with self-reported medical error and quality of care in this sample population. Measures need to be taken to address this issue, with a view to protecting health of NCHDs and maintaining quality of patient care. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  1. Design of a novel instrument for active neutron interrogation of artillery shells.

    Science.gov (United States)

    Bélanger-Champagne, Camille; Vainionpää, Hannes; Peura, Pauli; Toivonen, Harri; Eerola, Paula; Dendooven, Peter

    2017-01-01

    The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only) for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  2. Design of a novel instrument for active neutron interrogation of artillery shells.

    Directory of Open Access Journals (Sweden)

    Camille Bélanger-Champagne

    Full Text Available The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  3. Design of embedded hardware platform in intelligent γ-spectrometry instrument based on ARM9

    International Nuclear Information System (INIS)

    Hong Tianqi; Fang Fang

    2008-01-01

    This paper described the design of embedded hardware platform based on ARM9 S3C2410A, emphases are focused on analyzing the methods of design the circuits of memory, LCD and keyboard ports. It presented a new solution of hardware platform in intelligent portable instrument for γ measurement. (authors)

  4. Comparison of cyclic fatigue resistance of three different rotary nickel-titanium instruments designed for retreatment.

    Science.gov (United States)

    Inan, Ugur; Aydin, Cumhur

    2012-01-01

    A number of rotary nickel-titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system, and recently, rotary NiTi systems designed for root canal retreatment have been introduced. Because the main problem with the rotary NiTi files is fracture, the aim of this study was to compare the cyclic fatigue resistance of 3 different rotary NiTi systems designed for root canal retreatment. Total of 60 instruments of 3 different rotary NiTi systems designed for root canal retreatment were used in this study. Twenty R-Endo R3, 20 ProTaper D3, and 20 Mtwo R (Retreatment) 25.05 instruments were tested. Cyclic fatigue testing of instruments was performed by using a device that allowed the instruments to rotate freely inside an artificial canal. Each instrument was rotated until fracture occurred, and the number of cycles to fracture for each instrument was calculated. Representative samples were also evaluated under a scanning electron microscope to confirm the fracture was flexural. Data were analyzed by using 1-way analysis of variance test. R-Endo R3 instruments showed better cyclic fatigue resistance than ProTaper D3 and Mtwo R 25.05 instruments, and the difference was statistically significant (P instruments were more resistant to fatigue failure than ProTaper D3 and Mtwo R 25.05. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Key issues in the thermal design of spaceborne cryogenic infrared instruments

    Science.gov (United States)

    Schember, Helene R.; Rapp, Donald

    1992-12-01

    Thermal design and analysis play an integral role in the development of spaceborne cryogenic infrared (IR) instruments. From conceptual sketches to final testing, both direct and derived thermal requirements place significant constraints on the instrument design. Although in practice these thermal requirements are interdependent, the sources of most thermal constraints may be grouped into six distinct categories. These are: (1) Detector temperatures, (2) Optics temperatures, (3) Pointing or alignment stability, (4) Mission lifetime, (5) Orbit, and (6) Test and Integration. In this paper, we discuss these six sources of thermal requirements with particular regard to development of instrument packages for low background infrared astronomical observatories. In the end, the thermal performance of these instruments must meet a set of thermal requirements. The development of these requirements is typically an ongoing and interactive process, however, and the thermal design must maintain flexibility and robustness throughout the process. The thermal (or cryogenic) engineer must understand the constraints imposed by the science requirements, the specific hardware, the observing environment, the mission design, and the testing program. By balancing these often competing factors, the system-oriented thermal engineer can work together with the experiment team to produce an effective overall design of the instrument.

  6. Relationships between School Climate and Adolescent Students' Self-Reports of Ethnic and Moral Identity

    Science.gov (United States)

    Aldridge, Jill M.; Ala'i, Kate G.; Fraser, Barry J.

    2016-01-01

    This article reports research into associations between students' perceptions of the school climate and self-reports of ethnic and moral identity in high schools in Western Australia. An instrument was developed to assess students' perceptions of their school climate (as a means of monitoring and guiding schools as they are challenged to become…

  7. Detecting Learning Strategies with Analytics: Links with Self-Reported Measures and Academic Performance

    Science.gov (United States)

    Gaševic, Dragan; Jovanovic, Jelena; Pardo, Abelardo; Dawson, Shane

    2017-01-01

    The use of analytic methods for extracting learning strategies from trace data has attracted considerable attention in the literature. However, there is a paucity of research examining any association between learning strategies extracted from trace data and responses to well-established self-report instruments and performance scores. This paper…

  8. Self-Report Measures of Juvenile Psychopathic Personality Traits: A Comparative Review

    Science.gov (United States)

    Vaughn, Michael G.; Howard, Matthew O.

    2005-01-01

    The authors evaluated self-report instruments currently being used to assess children and adolescents with psychopathic personality traits with respect to their reliability, validity, and research utility. Comprehensive searches across multiple computerized bibliographic databases were conducted and supplemented with manual searches. A total of 30…

  9. Research on conceptual design of simplified nuclear safety instrument and control system

    International Nuclear Information System (INIS)

    Huang Jie

    2015-01-01

    The Nuclear safety instrument and control system is directly related to the safety of the reactor. So redundant and diversity design is used to ensure the system's security and reliability. This make the traditional safety system large, more cabinets and wiring complexity. To solve these problem, we can adopt new technology to make the design more simple. The simplify conceptual design can make the system less cabinets, less wiring, but high security, strong reliability. (author)

  10. A basic design of SR4 instrumentation and control system for research reactor

    International Nuclear Information System (INIS)

    Syahrudin Yusuf; M Subhan; Ikhsan Shobari; Sutomo Budihardjo

    2010-01-01

    An SR4 instrumentation and control systems of research reactor is the equipment of nuclear research reactors as power protection devices and control systems. The equipment is to monitor safety parameters and process parameters in the state of reactor shut down, start-up, and in operation at fixed power. In the engineering of Instrumentation and control systems SR4 research reactor, its basic design consists of technical specifications of the reactor protection system devices, technical specifications of the reactor power control system devices, technical specifications information system devices, and systems process termination cabling as a support system. This basic design is used as the basis for the preparation of detailed design and subsequent engineering development of instrumentation systems and control system integrated. (author)

  11. Higs-instrument: design and demonstration of a high performance gas concentration imager

    Science.gov (United States)

    Verlaan, A. L.; Klop, W. A.; Visser, H.; van Brug, H.; Human, J.

    2017-09-01

    Climate change and environmental conditions are high on the political agenda of international governments. Laws and regulations are being setup all around the world to improve the air quality and to reduce the impact. The growth of a number of trace gasses, including CO2, Methane and NOx are especially interesting due to their environmental impact. The regulations made are being based on both models and measurements of the trend of those trace gases over the years. Now the regulations are in place also enforcement and therewith measurements become more and more important. Instruments enabling high spectral and spatial resolution as well as high accurate measurements of trace gases are required to deliver the necessary inputs. Nowadays those measurements are usually performed by space based spectrometers. The requirement for high spectral resolution and measurement accuracy significantly increases the size of the instruments. As a result the instrument and satellite becomes very expensive to develop and to launch. Specialized instruments with a small volume and the required performance will offer significant advantages in both cost and performance. Huib's Innovative Gas Sensor (HIGS, named after its inventor Huib Visser), currently being developed at TNO is an instrument that achieves exactly that. Designed to measure only a single gas concentration, opposed to deriving it from a spectrum, it achieves high performance within a small design volume. The instrument enables instantaneous imaging of the gas distribution of the selected gas. An instrument demonstrator has been developed for NO2 detection. Laboratory measurements proved the measurement technique to be successful. An on-sky measurement campaign is in preparation. This paper addresses both the instrument design as well as the demonstrated performances.

  12. Requirements and design reference mission for the WFIRST/AFTA coronagraph instrument

    Science.gov (United States)

    Demers, Richard T.; Dekens, Frank; Calvet, Rob; Chang, Zensheu; Effinger, Robert; Ek, Eric; Hovland, Larry; Jones, Laura; Loc, Anthony; Nemati, Bijan; Noecker, Charley; Neville, Timothy; Pham, Hung; Rud, Mike; Tang, Hong; Villalvazo, Juan

    2015-09-01

    The WFIRST-AFTA coronagraph instrument takes advantage of AFTAs 2.4-meter aperture to provide novel exoplanet imaging science at approximately the same instrument cost as an Explorer mission. The AFTA coronagraph also matures direct imaging technologies to high TRL for an Exo-Earth Imager in the next decade. The coronagraph Design Reference Mission (DRM) optical design is based on the highly successful High Contrast Imaging Testbed (HCIT), with modifications to accommodate the AFTA telescope design, service-ability, volume constraints, and the addition of an Integral Field Spectrograph (IFS). In order to optimally satisfy the three science objectives of planet imaging, planet spectral characterization and dust debris imaging, the coronagraph is designed to operate in two different modes: Hybrid Lyot Coronagraph or Shaped Pupil Coronagraph. Active mechanisms change pupil masks, focal plane masks, Lyot masks, and bandpass filters to shift between modes. A single optical beam train can thus operate alternatively as two different coronagraph architectures. Structural Thermal Optical Performance (STOP) analysis predicts the instrument contrast with the Low Order Wave Front Control loop closed. The STOP analysis was also used to verify that the optical/structural/thermal design provides the extreme stability required for planet characterization in the presence of thermal disturbances expected in a typical observing scenario. This paper describes the instrument design and the flow down from science requirements to high level engineering requirements.

  13. Requirements and Design Reference Mission for the WFIRST-AFTA Coronagraph Instrument

    Science.gov (United States)

    Demers, Richard T.; Dekens, Frank; Calvet, Rob; Chang, Zensheu; Effinger, Robert; Ek, Eric; Hovland, Larry; Jones, Laura; Loc, Anthony; Nemati, Bijan; hide

    2015-01-01

    The WFIRST-AFTA coronagraph instrument take s advantage of AFTA s 2.4 -meter aperture to provide novel exoplanet imaging science at approximately the same instrument cost as an Explorer mission. The AFTA coronagraph also matures direct imaging technologies to high TRL for an Exo-Earth Imager in the next decade. The coronagraph Design Reference Mission (DRM) optical design is based on the highly successful High Contrast Imaging Testbed (HCIT), with modifications to accommodate the AFTA telescope design, service-ability, volume constraints, and the addition of an Integral Field Spectrograph (IFS). In order to optimally satisfy the three science objectives of planet imaging, planet spectral characterization and dust debris imaging, the coronagraph is designed to operate in two different modes : Hybrid Lyot Coronagraph or Shaped Pupil Coronagraph. Active mechanisms change pupil masks, focal plane masks, yot masks, and bandpass filters to shift between modes. A single optical beam train can thus operate alternatively as two different coronagraph architecture s. Structural Thermal Optical Performance (STOP) analysis predict s the instrument contrast with the Low Order Wave Front Control loop closed. The STOP analysis was also used to verify that the optical/structural/thermal design provides the extreme stability required for planet characterization in the presence of thermal disturbances expected in a typical observing scenario. This paper describes the instrument design and the flow down from science requirements to high level engineering requirements.

  14. The design and implementation of the Dynamic Ionosphere Cubesat Experiment (DICE) science instruments

    Science.gov (United States)

    Burr, Steven Reed

    Dynamic Ionosphere Cubesat Experiment (DICE) is a satellite project funded by the National Science Foundation (NSF) to study the ionosphere, more particularly Storm Enhanced Densities (SED) with a payload consisting of plasma diagnostic instrumentation. Three instruments onboard DICE include an Electric Field Probe (EFP), Ion Langmuir Probe (ILP), and Three Axis Magnetometer (TAM). The EFP measures electric fields from +/-8V and consists of three channels a DC to 40Hz channel, a Floating Potential Probe (FPP), and an spectrographic channel with four bands from 16Hz to 512Hz. The ILP measures plasma densities from 1x104 cm--3 to 2x107 cm--3. The TAM measures magnetic field strength with a range +/-0.5 Gauss with a sensitivity of 2nT. To achieve desired mission requirements careful selection of instrument requirements and planning of the instrumentation design to achieve mission success. The analog design of each instrument is described in addition to the digital framework required to sample the science data at a 70Hz rate and prepare the data for the Command and Data Handing (C&DH) system. Calibration results are also presented and show fulfillment of the mission and instrumentation requirements.

  15. Design concepts for a nuclear digital instrumentation and control system platform

    International Nuclear Information System (INIS)

    Ou, T. C.; Chen, C. K.; Chen, P. J.; Shyu, S. S.; Lee, C. L.; Hsieh, S. F.

    2010-10-01

    The objective of this paper is to present the development results of the nuclear instrumentation and control system in Taiwan. As the Taiwan nuclear power plants age, the need to consider upgrading of both their safety and non-safety-related instrumentation and control systems becomes more urgent. Meanwhile, the digital instrumentation and control system that is based on current fast evolving electronic and information technologies are difficult to maintain effectively. Therefore, Institute of Nuclear Energy Research was made a decision to promote the Taiwan Nuclear Instrumentation and Control System project to collaborate with domestic electronic industry to establish self-reliant capabilities on the design, manufacturing, and application of nuclear instrumentation and control systems with newer technology. In the case of safety-related applications like nuclear instrumentation and control, safety-oriented quality control is required. In order to establish a generic qualified digital platform, the world-wide licensing experience should be considered in the licensing process. This paper describes the qualification and certification tools by IEC 61508 for design and development of safety related equipment and explains the basis for many decisions made while performing the digital upgrade. (Author)

  16. Standards for radiation protection instrumentation: design of safety standards and testing procedures

    International Nuclear Information System (INIS)

    Meissner, Frank

    2008-01-01

    This paper describes by means of examples the role of safety standards for radiation protection and the testing and qualification procedures. The development and qualification of radiation protection instrumentation is a significant part of the work of TUV NORD SysTec, an independent expert organisation in Germany. The German Nuclear Safety Standards Commission (KTA) establishes regulations in the field of nuclear safety. The examples presented may be of importance for governments and nuclear safety authorities, for nuclear operators and for manufacturers worldwide. They demonstrate the advantage of standards in the design of radiation protection instrumentation for new power plants, in the upgrade of existing instrumentation to nuclear safety standards or in the application of safety standards to newly developed equipment. Furthermore, they show how authorities may proceed when safety standards for radiation protection instrumentation are not yet established or require actualization. (author)

  17. Design and manufacturing of instrumented capsule(03F-05K) for nuclear fuel irradiation in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Sohn, J. M.; Shin, Y. T. [and others

    2004-06-01

    An instrumented capsule is being developed to be able to measure fuel characteristics, such as fuel temperature, internal pressure of fuel rod, fuel elongation, and neutron flux, etc., during the irradiation test of nuclear fuel in HANARO. The instrumented capsule(02F-11K) for measuring and monitoring fuel centerline temperature and neutron flux was designed and manufactured. The instrumented capsule includes three test fuel rods installed thermocouple to measure fuel centerline temperature and three SPNDs (self-powered neutron detector) to monitor the neutron flux. Its stability was verified by out-of-pile performance test, and its safety evaluation was also shown that the safety requirements were satisfied. And then, to verify the design of the instrumented capsule in the test hole, it was successfully irradiated in the test hole of HANARO from March 14, 2003 to June 1, 2003 (53.8 full power days at 24 MWth). During irradiation, the centerline temperature of PWR UO{sub 2} fuel pellets fabricated by KEPCO Nuclear Fuel Company and the neutron flux were continuously measured and monitored. In the year of 2004, 3 test fuel rods and the instrumented capsule(03F-05K) were designed and fabricated to measure fuel centerline temperature, internal pressure of fuel rod, and fuel axial deformation during irradiation test. This capsule is being irradiated in the test hole OR5 of HANARO reactor from April 26, 2004.

  18. Design and evaluation of a new ergonomic handle for instruments in minimally invasive surgery.

    Science.gov (United States)

    Sancibrian, Ramon; Gutierrez-Diez, María C; Torre-Ferrero, Carlos; Benito-Gonzalez, Maria A; Redondo-Figuero, Carlos; Manuel-Palazuelos, Jose C

    2014-05-01

    Laparoscopic surgery techniques have been demonstrated to provide massive benefits to patients. However, surgeons are subjected to hardworking conditions because of the poor ergonomic design of the instruments. In this article, a new ergonomic handle design is presented. This handle is designed using ergonomic principles, trying to provide both more intuitive manipulation of the instrument and a shape that reduces the high-pressure zones in the contact with the surgeon's hand. The ergonomic characteristics of the new handle were evaluated using objective and subjective studies. The experimental evaluation was performed using 28 volunteers by means of the comparison of the new handle with the ring-handle (RH) concept in an instrument available on the market. The volunteers' muscle activation and motions of the hand, wrist, and arm were studied while they performed different tasks. The data measured in the experiment include electromyography and goniometry values. The results obtained from the subjective analysis reveal that most volunteers (64%) preferred the new prototype to the RH, reporting less pain and less difficulty to complete the tasks. The results from the objective study reveal that the hyperflexion of the wrist required for the manipulation of the instrument is strongly reduced. The new ergonomic handle not only provides important ergonomic advantages but also improves the efficiency when completing the tasks. Compared with RH instruments, the new prototype reduced the high-pressure areas and the extreme motions of the wrist. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Design and Implementation Content Validity Study: Development of an instrument for measuring Patient-Centered Communication

    Directory of Open Access Journals (Sweden)

    Vahid Zamanzadeh

    2015-06-01

    Full Text Available ABSTRACT Introduction: The importance of content validity in the instrument psychometric and its relevance with reliability, have made it an essential step in the instrument development. This article attempts to give an overview of the content validity process and to explain the complexity of this process by introducing an example. Methods: We carried out a methodological study conducted to examine the content validity of the patient-centered communication instrument through a two-step process (development and judgment. At the first step, domain determination, sampling (item generation and instrument formation and at the second step, content validity ratio, content validity index and modified kappa statistic was performed. Suggestions of expert panel and item impact scores are used to examine the instrument face validity. Results: From a set of 188 items, content validity process identified seven dimensions includes trust building (eight items, informational support (seven items, emotional support (five items, problem solving (seven items, patient activation (10 items, intimacy/friendship (six items and spirituality strengthening (14 items. Content validity study revealed that this instrument enjoys an appropriate level of content validity. The overall content validity index of the instrument using universal agreement approach was low; however, it can be advocated with respect to the high number of content experts that makes consensus difficult and high value of the S-CVI with the average approach, which was equal to 0.93. Conclusion: This article illustrates acceptable quantities indices for content validity a new instrument and outlines them during design and psychometrics of patient-centered communication measuring instrument.

  20. IB: A Monte Carlo simulation tool for neutron scattering instrument design under PVM and MPI

    International Nuclear Information System (INIS)

    Zhao Jinkui

    2011-01-01

    Design of modern neutron scattering instruments relies heavily on Monte Carlo simulation tools for optimization. IB is one such tool written in C++ and implemented under Parallel Virtual Machine and the Message Passing Interface. The program was initially written for the design and optimization of the EQ-SANS instrument at the Spallation Neutron Source. One of its features is the ability to group simple instrument components into more complex ones at the user input level, e.g. grouping neutron mirrors into neutron guides and curved benders. The simulation engine manages the grouped components such that neutrons entering a group are properly operated upon by all components, multiple times if needed, before exiting the group. Thus, only a few basic optical modules are needed at the programming level. For simulations that require higher computer speeds, the program can be compiled and run in parallel modes using either the PVM or the MPI architectures.

  1. CONCEPTUAL AND DESIGN ISSUES IN INSTRUMENT DEVELOPMENT FOR RESEARCH WITH BEREAVED PARENTS*

    Science.gov (United States)

    Briller, Sherylyn H.; Schim, Stephanie Myers; Thurston, Celia S.; Meert, Kathleen L.

    2013-01-01

    Many childhood deaths in the United States occur in pediatric intensive care units (PICUs) and parents have special needs in this death context. As an interdisciplinary research team, we discuss conceptual and design issues encountered in creating a new instrument, the Bereaved Parent Needs Assessment–PICU, for assessing parents’ needs in this setting. Using a qualitative approach, our team previously explored how the culture and related ways of providing care in one urban Midwestern children’s hospital PICU affected parents’ bereavement needs and experiences. We describe using this qualitative foundation in the development of a new quantitative instrument to more widely validate and measure bereaved parents’ needs around the time of a child’s death across multiple PICUs. We highlight a series of issues that warrant consideration in designing a research instrument for this vulnerable population including setting and context, format and content, temporality, recruitment, and content expertise. PMID:22953511

  2. Conceptual thermal design and analysis of a far-infrared/mid-infrared remote sensing instrument

    Science.gov (United States)

    Roettker, William A.

    1992-07-01

    This paper presents the conceptual thermal design and analysis results for the Spectroscopy of the Atmosphere using Far-Infrared Emission (SAFIRE) instrument. SAFIRE has been proposed for Mission to Planet Earth to study ozone chemistry in the middle atmosphere using remote sensing of the atmosphere in the far-infrared (21-87 microns) and mid-infrared (9-16 microns) spectra. SAFIRE requires that far-IR detectors be cooled to 3-4 K and mid-IR detectors to 80 K for the expected mission lifetime of five years. A superfluid helium dewar and Stirling-cycle cryocoolers provide the cryogenic temperatures required by the infrared detectors. The proposed instrument thermal design uses passive thermal control techniques to reject 465 watts of waste heat from the instrument.

  3. Design and operation of dust measuring instrumentation based on the beta-radiation method

    International Nuclear Information System (INIS)

    Lilienfeld, P.

    1975-01-01

    The theory, instrument design aspects and applications of beta-radiation attenuation for the measurement of the mass concentration of airborne particulates are reviewed. Applicable methods of particle collection, beta sensing configurations, source ( 63 Ni, 14 C, 147 Pr, 85 Kr) and detector design criteria, electronic signal processing, digital control and instrument programming techniques are treated. Advantages, limitations and error sources of beta-attenuation instrumentation are analyzed. Applications to industrial dust measurements, source testing, ambient monitoring, and particle size analysis are the major areas of practical utilization of this technique, and its inherent capability for automated and unattended operation provides compatibility with process control synchronization and alarm, telemetry, and incorporation into pollution monitoring network sensing stations. (orig.) [de

  4. Impression Management and Self-Report among Violent Offenders

    Science.gov (United States)

    Mills, Jeremy F.; Kroner, Daryl G.

    2006-01-01

    Offenders are assumed by many to employ socially desirable responding (SDR) response styles when completing self-report measures. Contrary to expectations, prior research has shown that accounting for SDR in self-report measures of antisocial constructs does not improve the relationship with outcome. Despite this, many self-report measures…

  5. A conceptual framework for designing micro electrical connectors for hearing aid instruments

    DEFF Research Database (Denmark)

    Doagou Rad, Saeed; Islam, Aminul; Fuglsang-Philip, M.

    2016-01-01

    technological advancements have urged them to incorporate increased number of electrical contacts. The current paper presents a conceptual framework for designing and manufacturing novel plug and socket systems for hearing aid instruments by using the state of art manufacturing technologies for micro components...

  6. Guide for design and application of protective instrumentation for experiments in the BSR and ORR

    International Nuclear Information System (INIS)

    West, K.W.

    1977-03-01

    This report is a guide for the design and application of protective instrumentation for experiments that are to be operated in the Bulk Shielding Reactor (BSR) or the Oak Ridge Research Reactor (ORR) and are to be connected to the reactor power-reduction and alarm systems

  7. Design, Validation, and Use of an Evaluation Instrument for Monitoring Systemic Reform.

    Science.gov (United States)

    Scantlebury, Kathryn; Boone, William; Kahle, Jane Butler; Fraser, Barry J.

    2001-01-01

    Describes the design, development, validation, and use of an instrument that measures student attitudes and several environmental dimensions (i.e., standards-based teaching, home support, and peer support). Indicates that the classroom environment (standards-based teaching practices) was the strongest independent predictor of both achievement and…

  8. The development of state/region owned goods management’s monitoring instrument design

    Directory of Open Access Journals (Sweden)

    Ikhwanto Yogy

    2017-01-01

    Full Text Available The problems in state/region owned goods in Indonesian state and local governments are suspected to occur because of weak monitoring programs, according to many studies. A tool or instrument in implementing this monitoring program is expected to address this problem. Such tool currently doesn’t exist yet. This research aims to fill that gap by developing a monitoring instrument design for state/region owned goods by using Daerah Istimewa Yogyakarta (DIY Local Government as a research context in order to take valuable inputs for the design. This research is using developmental research method. Government Regulation were used for normative reference and Friedman’s results-based accountability quadrat were used in developing good indicators for the instrument. This research is succeeded in formulating the indicators that made up the instrument. Indicators compiled are divided into compliance-based indicators and results-based indicators. Indicators are formulated based on the validation and inputs from employees of DIY’s Assets Management Agency and experts from academia. This instrument still has some limitations that need improvement through further research.

  9. DESIGNING AFFECTIVE INSTRUMENT BASED ON SCIENTIFIC APPROACH FOR ENGLISH LANGUAGE LEARNING

    Directory of Open Access Journals (Sweden)

    Maisarah Ira

    2018-01-01

    Full Text Available This research was describing the designing of instrument for affective assessment in English language teaching. The focus of the designing was only for observation sheet that will be used by English teachers during the teaching and learning process. The instrument was designed based on scientific approach that has five stages namely observing, questioning, experimenting, associating, and communicating. In the designing process, ADDIE Model was used as the method of research. The designing of instrument was considering the gap between the reality and the teachers’ need. The result showed that the designing was also notice to the affective taxonomy such as receiving, responding, valuing, organization, and characterization. Then, three key words were used as the indicator to show the five levels of affective taxonomy such as seriously, volunteer, and without asked by teacher. Furthermore, eighteen types of affective such as religious, honesty, responsible, discipline, hard work, self confidence, logical thinking, critical thinking, creative, innovative, independent, curiosity, love knowledge, respect, polite, democracy, emotional intelligence, and pluralist were put on each stage of scientific approach. So, it is hoped that can be implemented in all of context of English language teaching at schools and can assess the students’ affective comprehensively.

  10. Measurement properties of self-report physical activity assessment tools in stroke: a protocol for a systematic review.

    Science.gov (United States)

    Martins, Júlia Caetano; Aguiar, Larissa Tavares; Nadeau, Sylvie; Scianni, Aline Alvim; Teixeira-Salmela, Luci Fuscaldi; Faria, Christina Danielli Coelho de Morais

    2017-02-13

    Self-report physical activity assessment tools are commonly used for the evaluation of physical activity levels in individuals with stroke. A great variety of these tools have been developed and widely used in recent years, which justify the need to examine their measurement properties and clinical utility. Therefore, the main objectives of this systematic review are to examine the measurement properties and clinical utility of self-report measures of physical activity and discuss the strengths and limitations of the identified tools. A systematic review of studies that investigated the measurement properties and/or clinical utility of self-report physical activity assessment tools in stroke will be conducted. Electronic searches will be performed in five databases: Medical Literature Analysis and Retrieval System Online (MEDLINE) (PubMed), Excerpta Medica Database (EMBASE), Physiotherapy Evidence Database (PEDro), Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS) and Scientific Electronic Library Online (SciELO), followed by hand searches of the reference lists of the included studies. Two independent reviewers will screen all retrieve titles, abstracts, and full texts, according to the inclusion criteria and will also extract the data. A third reviewer will be referred to solve any disagreement. A descriptive summary of the included studies will contain the design, participants, as well as the characteristics, measurement properties, and clinical utility of the self-report tools. The methodological quality of the studies will be evaluated using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist and the clinical utility of the identified tools will be assessed considering predefined criteria. This systematic review will follow the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) statement. This systematic review will provide an extensive review of the measurement

  11. Measurement properties of self-report physical activity assessment tools in stroke: a protocol for a systematic review

    Science.gov (United States)

    Martins, Júlia Caetano; Aguiar, Larissa Tavares; Nadeau, Sylvie; Scianni, Aline Alvim; Teixeira-Salmela, Luci Fuscaldi; Faria, Christina Danielli Coelho de Morais

    2017-01-01

    Introduction Self-report physical activity assessment tools are commonly used for the evaluation of physical activity levels in individuals with stroke. A great variety of these tools have been developed and widely used in recent years, which justify the need to examine their measurement properties and clinical utility. Therefore, the main objectives of this systematic review are to examine the measurement properties and clinical utility of self-report measures of physical activity and discuss the strengths and limitations of the identified tools. Methods and analysis A systematic review of studies that investigated the measurement properties and/or clinical utility of self-report physical activity assessment tools in stroke will be conducted. Electronic searches will be performed in five databases: Medical Literature Analysis and Retrieval System Online (MEDLINE) (PubMed), Excerpta Medica Database (EMBASE), Physiotherapy Evidence Database (PEDro), Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS) and Scientific Electronic Library Online (SciELO), followed by hand searches of the reference lists of the included studies. Two independent reviewers will screen all retrieve titles, abstracts, and full texts, according to the inclusion criteria and will also extract the data. A third reviewer will be referred to solve any disagreement. A descriptive summary of the included studies will contain the design, participants, as well as the characteristics, measurement properties, and clinical utility of the self-report tools. The methodological quality of the studies will be evaluated using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist and the clinical utility of the identified tools will be assessed considering predefined criteria. This systematic review will follow the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) statement. Discussion This systematic review will

  12. Mechanical design and vibro-acoustic testing of ultrathin carbon foils for a spacecraft instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bernardin, John D [Los Alamos National Laboratory; Baca, Allen G [SNL

    2009-01-01

    IBEX-Hi is an electrostatic analyzer spacecraft instrument designed to measure the energy and flux distribution of energetic neutral atoms (ENAs) emanating from the interaction zone between the Earth's solar system and the Milky Way galaxy. A key element to this electro-optic instrument is an array of fourteen carbon foils that are used to ionize the ENAs. The foils are comprised of an ultrathin (50-100 {angstrom} thick) layer of carbon suspended across the surface of an electroformed Nickel wire screen, which in turn is held taught by a metal frame holder. The electro formed orthogonal screen has square wire elements, 12.7 {micro}m thick, with a pitch of 131.1 wires/cm. Each foil holder has an open aperture approximately 5 cm by 2.5 cm. Designing and implementing foil holders with such a large surface area has not been attempted for spaceflight in the past and has proven to be extremely challenging. The delicate carbon foils are subject to fatigue failure from the large acoustic and vibration loads that they will be exposed to during launch of the spacecraft. This paper describes the evolution of the foil holder design from previous space instrument applications to a flight-like IBEX-Hi prototype. Vibro-acoustic qualification tests of the IBEX-Hi prototype instrument and the resulting failure of several foils are summarized. This is followed by a discussion of iterative foil holder design modifications and laser vibrometer modal testing to support future fatigue failure analyses, along with additional acoustic testing of the IBEX-Hi prototype instrument. The results of these design and testing activities are merged and the resulting flight-like foil holder assembly is proposed.

  13. Is patient responsibility for managing musculoskeletal disorders related to self-reported better outcome of physiotherapy treatment?

    Science.gov (United States)

    Larsson, Maria E H; Kreuter, Margareta; Nordholm, Lena

    2010-07-01

    Musculoskeletal disorders are prevalent and a major burden on individuals and society. Information on relationships of patient involvement and responsibility to outcome is limited. This study aimed to explore relationships between self-reported outcome of physiotherapy treatment and attitudes toward responsibility for musculoskeletal disorders. A cross-sectional postal survey design was used. Patients (n=615) from an outpatient physiotherapy clinic, who had finished their physiotherapy treatment within the last 6 months were sent a questionnaire that included the Attitudes regarding Responsibility for Musculoskeletal disorders instrument (ARM), self-reported outcome of treatment and sociodemographic data. A total of 279 (45%) completed forms were returned. Multiple logistic regression analysis was used. The patients' scores on the four dimensions of ARM ("responsibility self active," "responsibility out of my hands," "responsibility employer," and "responsibility medical professionals"), controlled for age, sex, education, and physical activity as well as for number of treatments, main treatment, and physiotherapist, were associated with the patients' self-reported treatment outcome. Patients who attributed responsibility more to themselves were more likely (OR 2.37 and over) to report considerable improvement as the outcome of physiotherapy treatment. Because this study was conducted at only one physiotherapy outpatient clinic and had a cross-sectional design, the results should be replicated in other settings. Because patients' attitudes regarding responsibility for musculoskeletal disorders can possibly affect the outcome of physiotherapy treatment, it might be useful to decide whether to systematically try to influence the person's attitude toward responsibility for the management of the disorder or to match treatment to attitude.

  14. The LUVOIR Ultraviolet Multi-Object Spectrograph (LUMOS): instrument definition and design

    Science.gov (United States)

    France, Kevin; Fleming, Brian; West, Garrett; McCandliss, Stephan R.; Bolcar, Matthew R.; Harris, Walter; Moustakas, Leonidas; O'Meara, John M.; Pascucci, Ilaria; Rigby, Jane; Schiminovich, David; Tumlinson, Jason

    2017-08-01

    The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is one of four large mission concepts currently undergoing community study for consideration by the 2020 Astronomy and Astrophysics Decadal Survey. LUVOIR is being designed to pursue an ambitious program of exoplanetary discovery and characterization, cosmic origins astrophysics, and planetary science. The LUVOIR study team is investigating two large telescope apertures (9- and 15-meter primary mirror diameters) and a host of science instruments to carry out the primary mission goals. Many of the exoplanet, cosmic origins, and planetary science goals of LUVOIR require high-throughput, imaging spectroscopy at ultraviolet (100 - 400 nm) wavelengths. The LUVOIR Ultraviolet Multi-Object Spectrograph, LUMOS, is being designed to support all of the UV science requirements of LUVOIR, from exoplanet host star characterization to tomography of circumgalactic halos to water plumes on outer solar system satellites. LUMOS offers point source and multi-object spectroscopy across the UV bandpass, with multiple resolution modes to support different science goals. The instrument will provide low (R = 8,000 - 18,000) and medium (R = 30,000 - 65,000) resolution modes across the far-ultraviolet (FUV: 100 - 200 nm) and nearultraviolet (NUV: 200 - 400 nm) windows, and a very low resolution mode (R = 500) for spectroscopic investigations of extremely faint objects in the FUV. Imaging spectroscopy will be accomplished over a 3 × 1.6 arcminute field-of-view by employing holographically-ruled diffraction gratings to control optical aberrations, microshutter arrays (MSA) built on the heritage of the Near Infrared Spectrograph (NIRSpec) on the James Webb Space Telescope (JWST), advanced optical coatings for high-throughput in the FUV, and next generation large-format photon-counting detectors. The spectroscopic capabilities of LUMOS are augmented by an FUV imaging channel (100 - 200nm, 13 milliarcsecond angular resolution, 2 × 2

  15. Tool Trouble: Challenges with Using Self-Report Data to Evaluate Long-Term Chemistry Teacher Professional Development

    Science.gov (United States)

    Herrington, Deborah G.; Yezierski, Ellen J.; Bancroft, Senetta F.

    2016-01-01

    The purpose of this study was to compare the ability of different instruments, independently developed and traditionally used for measuring science teachers' beliefs in short-term interventions, to longitudinally measure teachers' changing beliefs. We compared the ability of three self-report instruments (Science Teaching Efficacy Belief…

  16. The measurement of disability in the elderly: a systematic review of self-reported questionnaires.

    Science.gov (United States)

    Yang, Ming; Ding, Xiang; Dong, Birong

    2014-02-01

    To analyze the contents and formats of general self-reported questionnaires on disability that are designed for and/or are widely applied in the elderly population to depict a complete picture of this field and help researchers to choose proper tools more efficiently. A broad systematic literature search was performed in September 2013 and included the following databases: MEDLINE, EMBASE, CINAHL, PsycINFO, and PROQOLID. The publication language was limited to English and Chinese. Two review authors independently performed the study selection and data extraction. All of the included instruments were extracted and classified using the International Classification of Functioning, Disability, and Health framework. Of 5569 articles retrieved from the searches and 156 articles retrieved from the pearling, 22 studies (including 24 questionnaires) fulfilled the inclusion criteria. From these, 42 different domains and 458 items were extracted. The most frequently used questionnaire was the Barthel Index followed by the Lawton and Brody Instrumental Activities of Daily Living Scale and the Katz Index of Activities of Daily Living, respectively. The contents and formats of the questionnaires varied considerably. Activities and participation were the most commonly assessed dimensions. In addition, the Activities of Daily Living, mobility and the Instrumental Activities of Daily Living Scale were the most common domains assessed among the included questionnaires. Among the 24 included questionnaires, the most frequently used questionnaires were the Barthel Index, Lawton and Brody Instrumental Activities of Daily Living Scale, and Katz Index of Activities of Daily Living. The content and format of the questionnaires varied considerably, but none of the questionnaires covered all essential dimensions of the International Classification of Functioning, Disability, and Health framework. Copyright © 2014 American Medical Directors Association, Inc. Published by Elsevier Inc. All

  17. Accuracy of Professional Self-Reports: Medical Student Self-Report and the Scoring of Professional Competence

    Science.gov (United States)

    Richter Lagha, Regina Anne

    2014-01-01

    Self-report is currently used as an indicator of professional practice in a variety of fields, including medicine and education. Important to consider, therefore, is the ability of self-report to accurately capture professional practice. This study investigated how well professionals' self-reports of behavior agreed with an expert observer's…

  18. A pilot's opinion - VTOL control design requirements for the instrument approach task.

    Science.gov (United States)

    Patton, J. M., Jr.

    1972-01-01

    This paper presents pilot opinion supported by test data concerning flight control and display concepts and control system design requirements for VTOL aircraft in the instrument approach task. Material presented is drawn from research flights in the following aircraft: Dornier DO-31, Short SC-1, LTV XC-142A, and Boeing-Vertol CH-46. The control system concepts and mechanizations employed in the above aircraft are discussed, and the effect of control system augmentation is shown on performance. Operational procedures required in the instrument approach task are described, with comments on need for automation and combining of control functions.

  19. Design of an 8-40 GHz Antenna for the Wideband Instrument for Snow Measurements (WISM)

    Science.gov (United States)

    Durham, Timothy E.; Vanhille, Kenneth J.; Trent, Christopher R.; Lambert, Kevin M.; Miranda, Felix A.

    2015-01-01

    This poster describes the implementation of a 6x6 element, dual linear polarized array with beamformer that operates from about 8-40 GHz. It is implemented using a relatively new multi-layer microfabrication process. The beamformer includes baluns that feed dual-polarized differential antenna elements and reactive splitters that cover the full frequency range of operation. This fixed beam array (FBA) serves as the feed for a multi-band instrument designed to measure snow water equivalent (SWE) from an airborne platform known as the Wideband Instrument for Snow Measurements (WISM).

  20. Aseismatic design of electrical equipments and instruments for nuclear power stations

    International Nuclear Information System (INIS)

    Suzuki, Yasuharu; Nishizawa, Kazuo; Miyazaki, Yoshio; Miura, Takumi

    1977-01-01

    The aseismatic design of electrical instruments is carried out according to IEEE Standard 344-1971 in the USA. In Japan also, the method of aseismatic design of electrical instruments has been investigated by the representatives of electric power companies and electric machine makers since 1972. In Hitachi Ltd., the statical method of confirming aseismatic property was established on the basis of the rigid design for electrical instruments. It is convenient to examine the aseismatic property of electrical equipments by classifying them into control and switch boards, electrical appliances, equipments and circuits. It is possible to use the static method treating earthquake force as static load by avoiding resonance with the electrical equipments which have the higher natural frequency than that of buildings. The purposes of the vibration test are to prove the validity of the theoretical analysis, to clarify the vibration characteristics, and to confirm the maintenance of functions and the strength of the equipments. The vibration tests of control boards, the switch boards of enclosed type, motor control centers, the racks for instrumentation, storage batteries and electrical appliances are explained. Moreover, the vibration analysis with a computer according to finite element method is described. (Kako, I.)

  1. Oral health status and self-reported functional dependence in community-dwelling older adults.

    Science.gov (United States)

    Yu, Yau-Hua; Lai, Yu-Lin; Cheung, Wai S; Kuo, Hsu-Ko

    2011-03-01

    To assess the strength of association between graded groups of oral health status and self-reported functional dependence in community-dwelling older adults. Population-based cross-sectional study. National Health and Nutritional Examination Survey (NHANES) 1999 to 2004. Three thousand eight hundred fifty-six participants aged 60 and older (mean age 71.2) without missing values in the examined correlates. Oral health status was evaluated according to edentulism, severity of periodontal disease, and recommendation of periodontal care and compared with that of healthy controls. Self-reported functional dependence was assessed according to 19 questions in five domains: activities of daily living (ADLs), instrumental activities of daily living (IADLs), leisure and social activities (LSAs), lower extremity mobility (LEM), and general physical activities (GPAs). After controlling for demographic and dental variables, health-related behaviors, C-reactive protein, and comorbidities, edentulism was significantly associated with disability in IADLs (odds ratio (OR)=1.58), LSAs (OR=1.63), LEM (OR=1.31), and GPAs (OR=1.45) compared with healthy controls. Likewise, severe periodontitis was associated with disability in IADLs (OR=1.58), LSAs (OR=1.70), and LEM (OR=1.63). The trends toward disability in IADLs, LSAs, LEM, and GPAs were statistically significant across increasing severity of oral health problems. Poor oral health, specifically edentulism and severe periodontitis, is associated with multiple domains of late-life disability, but a causal relationship cannot be established based on current study design. © 2011, Copyright the Authors. Journal compilation © 2011, The American Geriatrics Society.

  2. Conceptual phase A design of a cryogenic shutter mechanism for the SAFARI flight instrument

    Science.gov (United States)

    Eigenmann, Max; Wehmeier, Udo J.; Vuilleumier, Aurèle; Messina, Gabriele; Meyer, Michael R.

    2012-09-01

    We present a conceptual design for a cryogenic optical mechanism for the SAFARI instrument. SAFARI is a long wavelength (34-210 micron) Imaging Fourier Transform Spectrometer (FTS) to fly as an ESA instrument on the JAXA SPICA mission projected to launch in 2021. SPICA is a large 3m class space telescope which will have an operating temperature of less than 7K. The SAFARI shutter is a single point of failure flight mechanism designed to operate in space at a temperature of 4K which meets redundancy and reliability requirements of this challenging mission. The conceptual design is part of a phase A study led by ETH Institute for Astronomy and conducted by RUAG Space AG.

  3. Correction Capability in the 3 Anatomic Planes of Different Pedicle Screw Designs in Scoliosis Instrumentation.

    Science.gov (United States)

    Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy

    2017-05-01

    Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of

  4. Designing Successful Next-Generation Instruments to Detect the Epoch of Reionization

    Science.gov (United States)

    Thyagarajan, Nithyanandan; Hydrogen Epoch of Reionization Array (HERA) team, Murchison Widefield Array (MWA) team

    2018-01-01

    The Epoch of Reionization (EoR) signifies a period of intense evolution of the Inter-Galactic Medium (IGM) in the early Universe caused by the first generations of stars and galaxies, wherein they turned the neutral IGM to be completely ionized by redshift ≥ 6. This important epoch is poorly explored to date. Measurement of redshifted 21 cm line from neutral Hydrogen during the EoR is promising to provide the most direct constraints of this epoch. Ongoing experiments to detect redshifted 21 cm power spectrum during reionization, including the Murchison Widefield Array (MWA), Precision Array for Probing the Epoch of Reionization (PAPER), and the Low Frequency Array (LOFAR), appear to be severely affected by bright foregrounds and unaccounted instrumental systematics. For example, the spectral structure introduced by wide-field effects, aperture shapes and angular power patterns of the antennas, electrical and geometrical reflections in the antennas and electrical paths, and antenna position errors can be major limiting factors. These mimic the 21 cm signal and severely degrade the instrument performance. It is imperative for the next-generation of experiments to eliminate these systematics at their source via robust instrument design. I will discuss a generic framework to set cosmologically motivated antenna performance specifications and design strategies using the Precision Radio Interferometry Simulator (PRISim) -- a high-precision tool that I have developed for simulations of foregrounds and the instrument transfer function intended primarily for 21 cm EoR studies, but also broadly applicable to interferometer-based intensity mapping experiments. The Hydrogen Epoch of Reionization Array (HERA), designed in-part based on this framework, is expected to detect the 21 cm signal with high significance. I will present this framework and the simulations, and their potential for designing upcoming radio instruments such as HERA and the Square Kilometre Array (SKA).

  5. Validity of LIDAS (LIfetime Depression Assessment Self-report): a self-report online assessment of lifetime major depressive disorder.

    Science.gov (United States)

    Bot, M; Middeldorp, C M; de Geus, E J C; Lau, H M; Sinke, M; van Nieuwenhuizen, B; Smit, J H; Boomsma, D I; Penninx, B W J H

    2017-01-01

    There is a paucity of valid, brief instruments for the assessment of lifetime major depressive disorder (MDD) that can be used in, for example, large-scale genomics, imaging or biomarker studies on depression. We developed the LIfetime Depression Assessment Self-report (LIDAS), which assesses lifetime MDD diagnosis according to DSM criteria, and is largely based on the widely used Composite International Diagnostic Interview (CIDI). Here, we tested the feasibility and determined the sensitivity and specificity for measuring lifetime MDD with this new questionnaire, with a regular CIDI as reference. Sensitivity and specificity analyses of the online lifetime MDD questionnaire were performed in adults with (n = 177) and without (n = 87) lifetime MDD according to regular index CIDIs, selected from the Netherlands Study of Depression and Anxiety (NESDA) and Netherlands Twin Register (NTR). Feasibility was tested in an additional non-selective, population-based sample of NTR participants (n = 245). Of the 753 invited persons, 509 (68%) completed the LIDAS, of which 419 (82%) did this online. User-friendliness of the instrument was rated high. Median completion time was 6.2 min. Sensitivity and specificity for lifetime MDD were 85% [95% confidence interval (CI) 80-91%] and 80% (95% CI 72-89%), respectively. This LIDAS instrument gave a lifetime MDD prevalence of 20.8% in the population-based sample. Measuring lifetime MDD with an online instrument was feasible. Sensitivity and specificity were adequate. The instrument gave a prevalence of lifetime MDD in line with reported population prevalences. LIDAS is a promising tool for rapid determination of lifetime MDD status in large samples, such as needed for genomics studies.

  6. Design Through Integration of On-Board Calibration Device with Imaging Spectroscopy Instruments

    Science.gov (United States)

    Stange, Michael

    2012-01-01

    The main purpose of the Airborne Visible and Infrared Imaging Spectroscopy (AVIRIS) project is to "identify, measure, and monitor constituents of the Earth's surface and atmosphere based on molecular absorption and particle scattering signatures." The project designs, builds, and tests various imaging spectroscopy instruments that use On-Board Calibration devices (OBC) to check the accuracy of the data collected by the spectrometers. The imaging instrument records the spectral signatures of light collected during flight. To verify the data is correct, the OBC shines light which is collected by the imaging spectrometer and compared against previous calibration data to track spectral response changes in the instrument. The spectral data has the calibration applied to it based on the readings from the OBC data in order to ensure accuracy.

  7. The reliability, validity, and accuracy of self-reported absenteeism from work: a meta-analysis.

    Science.gov (United States)

    Johns, Gary; Miraglia, Mariella

    2015-01-01

    Because of a variety of access limitations, self-reported absenteeism from work is often employed in research concerning health, organizational behavior, and economics, and it is ubiquitous in large scale population surveys in these domains. Several well established cognitive and social-motivational biases suggest that self-reports of absence will exhibit convergent validity with records-based measures but that people will tend to underreport the behavior. We used meta-analysis to summarize the reliability, validity, and accuracy of absence self-reports. The results suggested that self-reports of absenteeism offer adequate test-retest reliability and that they exhibit reasonably good rank order convergence with organizational records. However, people have a decided tendency to underreport their absenteeism, although such underreporting has decreased over time. Also, self-reports were more accurate when sickness absence rather than absence for any reason was probed. It is concluded that self-reported absenteeism might serve as a valid measure in some correlational research designs. However, when accurate knowledge of absolute absenteeism levels is essential, the tendency to underreport could result in flawed policy decisions. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  8. Design of and initial results from a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC

    Directory of Open Access Journals (Sweden)

    D. R. Glowacki

    2007-10-01

    Full Text Available The design of a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC is described and initial results obtained from HIRAC are presented. The ability of HIRAC to perform in-situ laser-induced fluorescence detection of OH and HO2 radicals with the Fluorescence Assay by Gas Expansion (FAGE technique establishes it as internationally unique for a chamber of its size and pressure/temperature variable capabilities. In addition to the FAGE technique, HIRAC features a suite of analytical instrumentation, including: a multipass FTIR system; a conventional gas chromatography (GC instrument and a GC instrument for formaldehyde detection; NO/NO2, CO, O3, and H2O vapour analysers. Ray tracing simulations and NO2 actinometry have been utilized to develop a detailed model of the radiation field within HIRAC. Comparisons between the analysers and the FTIR coupled to HIRAC have been performed, and HIRAC has also been used to investigate pressure dependent kinetics of the chlorine atom reaction with ethene and the reaction of O3 and t-2-butene. The results obtained are in good agreement with literature recommendations and Master Chemical Mechanism predictions. HIRAC thereby offers a highly instrumented platform with the potential for: (1 high precision kinetics investigations over a range of atmospheric conditions; (2 detailed mechanism development, significantly enhanced according to its capability for measuring radicals; and (3 field instrument intercomparison, calibration, development, and investigations of instrument response at a range of atmospheric conditions.

  9. An ergonomics based design research method for the arrangement of helicopter flight instrument panels.

    Science.gov (United States)

    Alppay, Cem; Bayazit, Nigan

    2015-11-01

    In this paper, we study the arrangement of displays in flight instrument panels of multi-purpose civil helicopters following a user-centered design method based on ergonomics principles. Our methodology can also be described as a user-interface arrangement methodology based on user opinions and preferences. This study can be outlined as gathering user-centered data using two different research methods and then analyzing and integrating the collected data to come up with an optimal instrument panel design. An interview with helicopter pilots formed the first step of our research. In that interview, pilots were asked to provide a quantitative evaluation of basic interface arrangement principles. In the second phase of the research, a paper prototyping study was conducted with same pilots. The final phase of the study entailed synthesizing the findings from interviews and observational studies to formulate an optimal flight instrument arrangement methodology. The primary results that we present in our paper are the methodology that we developed and three new interface arrangement concepts, namely relationship of inseparability, integrated value and locational value. An optimum instrument panel arrangement is also proposed by the researchers. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  10. Design of a Prototype Differential Die‐Away Instrument Proposed for Swedish Spent Nuclear Fuel Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Martinik, Tomas, E-mail: tomas.martinik@physics.uu.se [Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden); Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Henzl, Vladimir [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Grape, Sophie; Jansson, Peter [Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden); Swinhoe, Martyn T.; Goodsell, Alison V. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Tobin, Stephen J. [Department of Physics and Astronomy, Uppsala University, Box 516, SE-75120 Uppsala (Sweden); Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Swedish Nuclear Fuel and Waste Management Company, Blekholmstorget 30, Box 250, SE-101 24 Stockholm (Sweden)

    2016-06-11

    As part of the United States (US) Department of Energy's Next Generation Safeguards Initiative Spent Fuel (NGSI-SF) project, the traditional Differential Die-Away (DDA) method that was originally developed for waste drum assay has been investigated and modified to provide a novel application to characterize or verify spent nuclear fuel (SNF). Following the promising, yet largely theoretical and simulation based, research of physics aspects of the DDA technique applied to SNF assay during the early stages of the NGSI-SF project, the most recent effort has been focused on the practical aspects of developing the first fully functional and deployable DDA prototype instrument for spent fuel. As a result of the collaboration among US research institutions and Sweden, the opportunity to test the newly proposed instrument's performance with commercial grade SNF at the Swedish Interim Storage Facility (Clab) emerged. Therefore the design of this instrument prototype has to accommodate the requirements of the Swedish regulator as well as specific engineering constrains given by the unique industrial environment. Within this paper, we identify key components of the DDA based instrument and we present methodology for evaluation and the results of a selection of the most relevant design parameters in order to optimize the performance for a given application, i.e. test-deployment, including assay of 50 preselected spent nuclear fuel assemblies of both pressurized (PWR) as well as boiling (BWR) water reactor type.

  11. Design verification test of instrumented capsule (02F-11K) for nuclear fuel irradiation in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Sohn, J. M.; Oh, J. M. [and others

    2004-01-01

    An instrumented capsule is being developed to be able to measure fuel characteristics, such as fuel temperature, internal pressure of fuel rod, fuel elongation, and neutron flux, etc., during the irradiation test of nuclear fuel in HANARO. The instrumented capsule for measuring and monitoring fuel centerline temperature and neutron flux was designed and manufactured. The instrumented capsule includes three test fuel rods installed thermocouple to measure fuel centerline temperature and three SPNDs (Self-Powered Neutron Detector) to monitor the neutron flux. Its stability was verified by out-of-pile performance test, and its safety evaluation was also shown that the safety requirements were satisfied. And then, to verify the design of the instrumented capsule in the test hole, it was successfully irradiated in the test hole of HANARO from March 14, 2003 to June 1, 2003 (53.8 full power days at 24 MWth). During irradiation, the centerline temperature of PWR UO{sub 2} fuel pellets fabricated by KEPCO Nuclear Fuel Company and the neutron flux were continuously measured and monitored. The test fuel rods were irradiated at less than 350 W/cm to 5.13 GWD/MTU with fuel centerline peak temperature below 1,375 .deg. C. The structural stability of the capsule was satisfied by the naked eye in service pool of HANARO. The capsule and test fuel rods were dismantled and test fuel rods were examined at the hot cell of IMEF (Irradiated Material Examination Facility)

  12. Testing the Solar Probe Cup, an Instrument Designed to Touch the Sun

    Science.gov (United States)

    Whittlesey, Phyllis L.; Case, Anthony W.; Kasper, Justin Christophe; Wright, Kenneth H., Jr.; Alterman, Ben; Cirtain, Jonathan W.; Bookbinder, Jay; Korreck, Kelly E.; Stevens, Michael Louis

    2014-01-01

    Solar Probe Plus will be the first, fastest, and closest mission to the sun, providing the first direct sampling of the sub-Alfvenic corona. The Solar Probe Cup (SPC) is a unique re-imagining of the traditional Faraday Cup design and materials for immersion in this high temperature environment. Sending an instrument of this type into a never-seen particle environment requires extensive characterization prior to launch to establish sufficient measurement accuracy and instrument response. To reach this end, a slew of tests for allowing SPC to see ranges of appropriate ions and electrons, as well as a facility that reproduces solar photon spectra and fluxes for this mission. Having already tested the SPC at flight like temperatures with no significant modification of the noise floor, we recently completed a round of particle testing to see if the deviations in Faraday Cup design fundamentally change the operation of the instrument. Results and implications from these tests will be presented, as well as performance comparisons to cousin instruments such as those on the WIND spacecraft.

  13. Thermal design and performance of the REgolith x-ray imaging spectrometer (REXIS) instrument

    Science.gov (United States)

    Stout, Kevin D.; Masterson, Rebecca A.

    2014-08-01

    The REgolith X-ray Imaging Spectrometer (REXIS) instrument is a student collaboration instrument on the OSIRIS-REx asteroid sample return mission scheduled for launch in September 2016. The REXIS science mission is to characterize the elemental abundances of the asteroid Bennu on a global scale and to search for regions of enhanced elemental abundance. The thermal design of the REXIS instrument is challenging due to both the science requirements and the thermal environment in which it will operate. The REXIS instrument consists of two assemblies: the spectrometer and the solar X-ray monitor (SXM). The spectrometer houses a 2x2 array of back illuminated CCDs that are protected from the radiation environment by a one-time deployable cover and a collimator assembly with coded aperture mask. Cooling the CCDs during operation is the driving thermal design challenge on the spectrometer. The CCDs operate in the vicinity of the electronics box, but a 130 °C thermal gradient is required between the two components to cool the CCDs to -60 °C in order to reduce noise and obtain science data. This large thermal gradient is achieved passively through the use of a copper thermal strap, a large radiator facing deep space, and a two-stage thermal isolation layer between the electronics box and the DAM. The SXM is mechanically mounted to the sun-facing side of the spacecraft separately from the spectrometer and characterizes the highly variable solar X-ray spectrum to properly interpret the data from the asteroid. The driving thermal design challenge on the SXM is cooling the silicon drift detector (SDD) to below -30 °C when operating. A two-stage thermoelectric cooler (TEC) is located directly beneath the detector to provide active cooling, and spacecraft MLI blankets cover all of the SXM except the detector aperture to radiatively decouple the SXM from the flight thermal environment. This paper describes the REXIS thermal system requirements, thermal design, and analyses, with

  14. The Gas Turbine Modular Helium Reactor Optimum Design for Instrumentation and Control

    International Nuclear Information System (INIS)

    Quinn, Edward 'Ted'; Rodriguez, Carmelo

    2002-01-01

    Nuclear power plants rely on instrumentation and control (I and C) systems for monitoring, control and protection. While the earlier generations of nuclear plants were built with largely analog instrumentation systems, the industrial base has moved to digital based system. The reason for this transition to digital I and C systems lies in their important advantage over existing analog systems. In essence, the challenge is to prove that the new digital guidelines included in NUREG 0800, Standard Review Plan Chapter 7 and all associated documents provided adequate direction and safety review for an advanced control design for a new nuclear plant in the United States. This paper focuses on how one of the new designs incorporates the latest technology and meets the new NRC requirements. (authors)

  15. Design of improved detection instrumentation for the annulus gas system for wolsong 2

    International Nuclear Information System (INIS)

    Kim, Seog Nam; Koo, Jun Mo; Chang, Ik Ho; Jung, Ho Chang; Han, Sang Joon

    1996-01-01

    The improved and advanced Annulus Gas System (AGS) has been developed for Wolsong 2 to satisfy the requirements of the regulatory body. The Atomic Energy Control Board (AECB) required a shorter detection time following a small leak from a pressure tube and/or calandria tube. This paper describes licensing requirements, functional requirements and detail design description for the AGS. The Wolsong unit No. 1 AGS was designed to operate as a stagnant system normally requiring only pressure regulation and having provisions for purging. The improved AGS involves the adoption of gas recirculation in AGS, duplication of dew point indicators with additional instrumentation and sampling provisions to prompt operator action. The improved system operates in the recirculation mode with continuous dew point measurement for leak detection. An AGS with improved detection instrumentation is provided. 8 refs., 3 figs. (author)

  16. High intensity multi beam design of SANS instrument for Dhruva reactor

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Sohrab, E-mail: abbas@barc.gov.in; Aswal, V. K. [Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Désert, S. [Laboratoire Leon Brillouin, CEA, Saclay, 91191 (France)

    2016-05-23

    A new and versatile design of Small Angle Neutron Scattering (SANS) instrument based on utilization of multi-beam is presented. The multi-pinholes and multi-slits as SANS collimator for medium flux Dhruva rearctor have been proposed and their designs have been validated using McStas simulations. Various instrument configurations to achieve different minimum wave vector transfers in scattering experiments are envisioned. These options enable smooth access to minimum wave vector transfers as low as ~ 6×10{sup −4} Å{sup −1} with a significant improvement in neutron intensity, allowing faster measurements. Such angularly well defined and intense neutron beam will allow faster SANS studies of agglomerates larger than few tens of nm.

  17. The Design and Development of Driving Game as an Evaluation Instrument for Driving License Test

    OpenAIRE

    Abdul Hadi Abdul Razak; Mohd Hairy Manap

    2013-01-01

    The focus of this paper is to highlight the design and development of an educational game prototype as an evaluation instrument for the Malaysia driving license static test. This educational game brings gaming technology into the conventional objective static test to make it more effective, real and interesting. From the feeling of realistic, the future driver can learn something, memorized and use it in the real life. The current online objective static test only make th...

  18. A conceptual framework for designing micro electrical connectors for hearing aid instruments

    OpenAIRE

    Doagou Rad, Saeed; Islam, Aminul; Fuglsang-Philip, M.

    2016-01-01

    Electrical connectors play vital roles in modern electronic instruments. Hearing aid devices as advanced combinations of micro mechanics and electronics comprise various electrical connectors for different purposes. However, the current trend in the miniaturization along with the sharp technological advancements have urged them to incorporate increased number of electrical contacts. The current paper presents a conceptual framework for designing and manufacturing novel plug and socket systems...

  19. Interformat reliability of digital psychiatric self-report questionnaires: a systematic review.

    Science.gov (United States)

    Alfonsson, Sven; Maathz, Pernilla; Hursti, Timo

    2014-12-03

    Research on Internet-based interventions typically use digital versions of pen and paper self-report symptom scales. However, adaptation into the digital format could affect the psychometric properties of established self-report scales. Several studies have investigated differences between digital and pen and paper versions of instruments, but no systematic review of the results has yet been done. This review aims to assess the interformat reliability of self-report symptom scales used in digital or online psychotherapy research. Three databases (MEDLINE, Embase, and PsycINFO) were systematically reviewed for studies investigating the reliability between digital and pen and paper versions of psychiatric symptom scales. From a total of 1504 publications, 33 were included in the review, and interformat reliability of 40 different symptom scales was assessed. Significant differences in mean total scores between formats were found in 10 of 62 analyses. These differences were found in just a few studies, which indicates that the results were due to study effects and sample effects rather than unreliable instruments. The interformat reliability ranged from r=.35 to r=.99; however, the majority of instruments showed a strong correlation between format scores. The quality of the included studies varied, and several studies had insufficient power to detect small differences between formats. When digital versions of self-report symptom scales are compared to pen and paper versions, most scales show high interformat reliability. This supports the reliability of results obtained in psychotherapy research on the Internet and the comparability of the results to traditional psychotherapy research. There are, however, some instruments that consistently show low interformat reliability, suggesting that these conclusions cannot be generalized to all questionnaires. Most studies had at least some methodological issues with insufficient statistical power being the most common issue

  20. [System design of small intellectualized ultrasound hyperthermia instrument in the LabVIEW environment].

    Science.gov (United States)

    Jiang, Feng; Bai, Jingfeng; Chen, Yazhu

    2005-08-01

    Small-scale intellectualized medical instrument has attracted great attention in the field of biomedical engineering, and LabVIEW (Laboratory Virtual Instrument Engineering Workbench) provides a convenient environment for this application due to its inherent advantages. The principle and system structure of the hyperthermia instrument are presented. Type T thermocouples are employed as thermotransducers, whose amplifier consists of two stages, providing built-in ice point compensation and thus improving work stability over temperature. Control signals produced by specially designed circuit drive the programmable counter/timer 8254 chip to generate PWM (Pulse width modulation) wave, which is used as ultrasound radiation energy control signal. Subroutine design topics such as inner-tissue real time feedback temperature control algorithm, water temperature control in the ultrasound applicator are also described. In the cancer tissue temperature control subroutine, the authors exert new improvments to PID (Proportional Integral Differential) algorithm according to the specific demands of the system and achieve strict temperature control to the target tissue region. The system design and PID algorithm improvement have experimentally proved to be reliable and excellent, meeting the requirements of the hyperthermia system.

  1. Cross-sectional study of anxiety symptoms and self-report of awake and sleep bruxism in female TMD patients.

    Science.gov (United States)

    Tavares, Luisa Maria Faria; da Silva Parente Macedo, Leonora Cristina; Duarte, Cristina Maria Rabelais; de Goffredo Filho, Gilberto Senechal; de Souza Tesch, Ricardo

    2016-11-01

    The aim of this study was to assess the relationship between levels of anxiety symptoms and prevalence of self-report of awake and sleep bruxism in patients with temporomandibular disorders (TMD). One hundred and eighty-one female patients, aged 19-77 years, were consecutively evaluated. The patients were selected from among those who sought treatment at the TMD and Orofacial Pain Outpatient Clinic of the Petrópolis School of Medicine. All patients completed the questionnaire and underwent clinical examination, both components of the RDC/TMD, in addition to answering questions pertaining to the assessment of levels of anxiety symptoms, taken from the Symptom Check List 90 self-report instrument. The subjects were classified according to the presence of self-reported only awake bruxism, only sleep bruxism, both, or none. A logistic regression procedure was performed to evaluate the possible association through odds ratio between anxiety symptoms and self-reported awake or sleep bruxism. The cofactors for each outcome were age, self-reported bruxism during the circadian period other than the one being evaluated, and the use of selective serotonin reuptake inhibitors. It was possible to demonstrate the presence of a positive and statistically significant relationship between anxiety levels and self-reported awake bruxism. This finding was not observed in those subjects who reported sleep bruxism. A positive relationship was found between self-reported awake bruxism and levels of anxiety symptoms, but not between sleep bruxism and anxiety.

  2. State-of-the-Art Report on the Piping and Instrumentation Design of RHRS in the Commercial NPPs

    International Nuclear Information System (INIS)

    Lee, Jun; Park, C. T.; Kim, Y. I.; Kim, S. H.; Choi, B. S.; Yoon, Ju Hyeon

    2004-12-01

    The objective of the study is for system designers to understand the technical state of the piping and instrumentation design of RHRS (or SCS) in the commercial nuclear power plants, thus to design more uncomplicated and advanced system. In this study, we have reviewed the design requirements and the technical state of piping and instrumentation design. Firstly we have reviewed the design requirements, including functional, isolation, pressure relief, pump protection, test requirements, etc.. Especially we have separately reviewed the design requirements of the low temperature overpressure, including ASME code requirements. Also we have reviewed the technical state of piping and instrumentation design, including piping design, PAMS design, ESFAS design, relief valve design, and instrument/valve/pump control design. In the piping design, the technical state of design has been investigated classified by the five regions, which have a little different design features, from the RCS suction line to the LPSI header line. Commonly, the P and ID is the design output which the related design requirements of the system have been all applied, also the operations for in-service inspection, heat-up/normal/cool-down, and emergency have been all considered. If we can understand well the design bases and its meanings of the P and ID, it would be helpful for us to design more uncomplicated and advanced system

  3. Design and construction of an instrument for measuring thermistor electrical characteristic

    International Nuclear Information System (INIS)

    Budiono; Yudi Herdiana

    2007-01-01

    In this work an instrument for measuring the electrical characteristic of thermistor has been designed and constructed. The instrument was constructed from main components i.e. a micro controller AT89C51, 3 ADC-0804, a LM35 temperature sensor and IC MAX 232. The IC MAX 232 component is used to connect the micro controller to the personal computer serially by using RS-232 standard. While ADC-0804 was used to convert the analog data (DC voltage) to the digital one so that the data was readable by the micro controller. Digital data from 3 ADC-0804 circuit which have been read by the micro controller was sent directly to the personal computer. The data from the measurement which have been stored in the personal computer was then processed to know the value of temperature and measured thermistor resistance. The processed data could be either stored in a data base or displayed in a monitor or printed in the form of table data and in the form a graph of thermistor resistance as the function of temperature. The result of measurement from measuring instrument of the characteristic of thermistor electric's had been made, being compared by measuring calibrated instrument, the deviation is about 0.33 %. (author)

  4. Principles relating to the digital instrumentation and control design approach 2017

    International Nuclear Information System (INIS)

    2017-01-01

    The design of the instrumentation and control of nuclear facilities uses digital systems that offer increasing computation and interconnection capabilities. They enable advanced functions to be carried out, such as calculation of the critical heat flux ratio, help to detect hardware failures in real time and provide operators with rich, flexible interfaces. However, these evolved functions may be affected by faults that make their logic systematically inadequate in certain cases, which introduces sources of failure other than random hardware failures and raises questions about the informal concept of the increased 'complexity' of instrumentation and control. Appropriate design principles shall therefore be applied so that this logic is as fault-free as possible and can be assessed by an independent body such as IRSN. This document presents the main problems associated with the design of the digital instrumentation and control of a complex facility, as well as the general principles to follow to demonstrate that a satisfactory safety level has been achieved. The doctrine elements presented in this document are the result of the experience acquired during assessments carried out for the French nuclear power plants, enhanced by exchanges with experts from the nuclear sector, and reflect French practice; they apply in other sectors in which a high level of confidence can be attributed to instrumentation and control. The normative texts cited in this document provide detailed requirements that are open to considerable interpretation, as the nature of the problem posed does not enable relevant and measurable criteria to be defined in all cases. This document aims to explain the principles underlying these detailed requirements and to give the means for interpreting them in each situation. (authors)

  5. Training Early Career Scientists in Flight Instrument Design Through Experiential Learning: NASA Goddard's Planetary Science Winter School.

    Science.gov (United States)

    Bleacher, L. V.; Lakew, B.; Bracken, J.; Brown, T.; Rivera, R.

    2017-01-01

    The NASA Goddard Planetary Science Winter School (PSWS) is a Goddard Space Flight Center-sponsored training program, managed by Goddard's Solar System Exploration Division (SSED), for Goddard-based postdoctoral fellows and early career planetary scientists. Currently in its third year, the PSWS is an experiential training program for scientists interested in participating on future planetary science instrument teams. Inspired by the NASA Planetary Science Summer School, Goddard's PSWS is unique in that participants learn the flight instrument lifecycle by designing a planetary flight instrument under actual consideration by Goddard for proposal and development. They work alongside the instrument Principal Investigator (PI) and engineers in Goddard's Instrument Design Laboratory (IDL; idc.nasa.gov), to develop a science traceability matrix and design the instrument, culminating in a conceptual design and presentation to the PI, the IDL team and Goddard management. By shadowing and working alongside IDL discipline engineers, participants experience firsthand the science and cost constraints, trade-offs, and teamwork that are required for optimal instrument design. Each PSWS is collaboratively designed with representatives from SSED, IDL, and the instrument PI, to ensure value added for all stakeholders. The pilot PSWS was held in early 2015, with a second implementation in early 2016. Feedback from past participants was used to design the 2017 PSWS, which is underway as of the writing of this abstract.

  6. Design of optical instruments; Proceedings of the Meeting, Orlando, FL, Apr. 22-24, 1992

    Science.gov (United States)

    Aikens, David M.; Genberg, Victor L.; Krumweide, Gary C.; Thomas, Michael J.

    1992-09-01

    Topics discussed in this volume include optical system design, recent application of composite materials to precision optical instrument structure, development of composite mirrors and reflectos, development of composite materials for dimensionally stable structures, and structural mechanics. Papers are presented on adjustable distortion correctors, the optical design for the ATLAS multispectral scanner, an internal thermal emission analysis of an IR seeker, recent developments with the Mars Observer Camera graphite/epoxy structure, and moisture effects and control for the Ultraviolet Coronagraph Spectrograph composite structure. Attention is also given to composite materials for precision space reflector panels, the structural design and analysis for an ultralow-CTE optical bench for the Hubbale Space Telescope corrective optics, the evaluation of high-modulus pitch/cyanate material systems for dimensionally stable structures, weight minimization of an active mirror, and a compliant optical mount design. (For individual items see A93-29782 to A93-29798)

  7. Instrumentation and control of future sodium cooled fast reactors - Design improvements

    International Nuclear Information System (INIS)

    Madhusoodanan, K.; Sakthivel, M.; Chellapandi, P.

    2013-06-01

    India's fast reactor program started with the 40 MWt Fast Breeder Test Reactor. 500 MWe Prototype Fast Breeder Reactor (PFBR) is currently under construction at Kalpakkam. Safety of PFBR is enhanced by improved design features of I and C system. Since the design of Instrumentation and control (I and C) of PFBR, considerable improvements in terms of advancement in technology and indigenization has taken place. Further improvements in I and C is proposed for solving many of the difficulties faced during the design and construction phases of PFBR. Design improvements proposed are covered in this paper which will make the implementation and maintenance of I and C of future SFRs easier. (authors)

  8. Michelson Interferometer for Global High-Resolution Thermospheric Imaging (MIGHTI): Instrument Design and Calibration

    Science.gov (United States)

    Englert, Christoph R.; Harlander, John M.; Brown, Charles M.; Marr, Kenneth D.; Miller, Ian J.; Stump, J. Eloise; Hancock, Jed; Peterson, James Q.; Kumler, Jay; Morrow, William H.; Mooney, Thomas A.; Ellis, Scott; Mende, Stephen B.; Harris, Stewart E.; Stevens, Michael H.; Makela, Jonathan J.; Harding, Brian J.; Immel, Thomas J.

    2017-10-01

    The Michelson Interferometer for Global High-resolution Thermospheric Imaging (MIGHTI) instrument was built for launch and operation on the NASA Ionospheric Connection Explorer (ICON) mission. The instrument was designed to measure thermospheric horizontal wind velocity profiles and thermospheric temperature in altitude regions between 90 km and 300 km, during day and night. For the wind measurements it uses two perpendicular fields of view pointed at the Earth's limb, observing the Doppler shift of the atomic oxygen red and green lines at 630.0 nm and 557.7 nm wavelength. The wavelength shift is measured using field-widened, temperature compensated Doppler Asymmetric Spatial Heterodyne (DASH) spectrometers, employing low order échelle gratings operating at two different orders for the different atmospheric lines. The temperature measurement is accomplished by a multichannel photometric measurement of the spectral shape of the molecular oxygen A-band around 762 nm wavelength. For each field of view, the signals of the two oxygen lines and the A-band are detected on different regions of a single, cooled, frame transfer charge coupled device (CCD) detector. On-board calibration sources are used to periodically quantify thermal drifts, simultaneously with observing the atmosphere. The MIGHTI requirements, the resulting instrument design and the calibration are described.

  9. 7-GeV Advanced Photon Source Instrumentation Initiative conceptual design report

    International Nuclear Information System (INIS)

    1992-12-01

    In this APS Instrumentation Initiative, 2.5-m-long and 5-m-long insertion-device x-ray sources will be built on 9 straight sections of the APS storage ring, and an additional 9 bending-magnet sources will also be put in use. The front ends for these 18 x-ray sources will be built to contain and safeguard access to these bright x-ray beams. In addition, funds will be provided to build state-of-the-art insertion-device beamlines to meet scientific and technological research demands well into the next century. This new initiative will also include four user laboratory modules and a special laboratory designed to meet the x-ray imaging research needs of the users. The Conceptual Design Report (CDR) for the APS Instrumentation Initiative describes the scope of all the above technical and conventional construction and provides a detailed cost and schedule for these activities. According to these plans, this new initiative begins in FY 1994 and ends in FY 1998. The document also describes the preconstruction R ampersand D plans for the Instrumentation Initiative activities and provides the cost estimates for the required R ampersand D

  10. Software design for the VIS instrument onboard the Euclid mission: a multilayer approach

    Science.gov (United States)

    Galli, E.; Di Giorgio, A. M.; Pezzuto, S.; Liu, S. J.; Giusi, G.; Li Causi, G.; Farina, M.; Cropper, M.; Denniston, J.; Niemi, S.

    2014-07-01

    The Euclid mission scientific payload is composed of two instruments: a VISible Imaging Instrument (VIS) and a Near Infrared Spectrometer and Photometer instrument (NISP). Each instrument has its own control unit. The Instrument Command and Data Processing Unit (VI-CDPU) is the control unit of the VIS instrument. The VI-CDPU is connected directly to the spacecraft by means of a MIL-STD-1553B bus and to the satellite Mass Memory Unit via a SpaceWire link. All the internal interfaces are implemented via SpaceWire links and include 12 high speed lines for the data provided by the 36 focal plane CCDs readout electronics (ROEs) and one link to the Power and Mechanisms Control Unit (VI-PMCU). VI-CDPU is in charge of distributing commands to the instrument sub-systems, collecting their housekeeping parameters and monitoring their health status. Moreover, the unit has the task of acquiring, reordering, compressing and transferring the science data to the satellite Mass Memory. This last feature is probably the most challenging one for the VI-CDPU, since stringent constraints about the minimum lossless compression ratio, the maximum time for the compression execution and the maximum power consumption have to be satisfied. Therefore, an accurate performance analysis at hardware layer is necessary, which could delay too much the design and development of software. In order to mitigate this risk, in the multilayered design of software we decided to design a middleware layer that provides a set of APIs with the aim of hiding the implementation of the HW connected layer to the application one. The middleware is built on top of the Operating System layer (which includes the Real-Time OS that will be adopted) and the onboard Computer Hardware. The middleware itself has a multi-layer architecture composed of 4 layers: the Abstract RTOS Adapter Layer (AOSAL), the Speci_c RTOS Adapter Layer (SOSAL), the Common Patterns Layer (CPL), the Service Layer composed of two subgroups which

  11. Psychometric evaluation of self-report outcome measures for prosthetic applications

    OpenAIRE

    Hafner, Brian J.; Morgan, Sara J.; Askew, Robert L.; Salem, Rana

    2016-01-01

    Documentation of clinical outcomes is increasingly expected in delivery of prosthetic services and devices. However, many outcome measures suitable for use in clinical care and research have not been psychometrically tested with prosthesis users. The aim of this study was to determine test-retest reliability, mode-of-administration (MoA) equivalence, standard error of measurement (SEM), and minimal detectable change (MDC) of standardized, self-report instruments that assess constructs of impo...

  12. Impact of Passive Safety on FHR Instrumentation Systems Design and Classification

    International Nuclear Information System (INIS)

    Holcomb, David Eugene

    2015-01-01

    Fluoride salt-cooled high-temperature reactors (FHRs) will rely more extensively on passive safety than earlier reactor classes. 10CFR50 Appendix A, General Design Criteria for Nuclear Power Plants, establishes minimum design requirements to provide reasonable assurance of adequate safety. 10CFR50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors, provides guidance on how the safety significance of systems, structures, and components (SSCs) should be reflected in their regulatory treatment. The Nuclear Energy Institute (NEI) has provided 10 CFR 50.69 SSC Categorization Guideline (NEI-00-04) that factors in probabilistic risk assessment (PRA) model insights, as well as deterministic insights, through an integrated decision-making panel. Employing the PRA to inform deterministic requirements enables an appropriately balanced, technically sound categorization to be established. No FHR currently has an adequate PRA or set of design basis accidents to enable establishing the safety classification of its SSCs. While all SSCs used to comply with the general design criteria (GDCs) will be safety related, the intent is to limit the instrumentation risk significance through effective design and reliance on inherent passive safety characteristics. For example, FHRs have no safety-significant temperature threshold phenomena, thus enabling the primary and reserve reactivity control systems required by GDC 26 to be passively, thermally triggered at temperatures well below those for which core or primary coolant boundary damage would occur. Moreover, the passive thermal triggering of the primary and reserve shutdown systems may relegate the control rod drive motors to the control system, substantially decreasing the amount of safety-significant wiring needed. Similarly, FHR decay heat removal systems are intended to be running continuously to minimize the amount of safety-significant instrumentation needed to initiate

  13. Relations Between Self-Reported and Linguistic Monitoring Assessments of Affective Experience in an Extreme Environment.

    Science.gov (United States)

    Smith, Nathan

    2018-03-01

    Approaches for monitoring psychosocial health in challenging environments are needed to maintain the performance and safety of personnel. The purpose of the present research was to examine the relationship between 2 candidate methods (self-reported and linguistics) for monitoring affective experience during extreme environment activities. A single-subject repeated-measures design was used in the present work. The participant was a 46-year-old individual scheduled to complete a self-supported ski expedition across Arctic Greenland. The expedition lasted 28 days, and conditions included severe cold, low stimulation, whiteouts, limited habitability, and threats to life and limb. During the expedition, the participant completed a daily self-report log including assessment of psychological health (perceptions of control and affect) and a video diary (emotion). Video diary entries were subjected to linguistic inquiry and word count analyses before the links between self-report and linguistic data across the expedition period were tested. Similarities in the pattern of self-reported and linguistic assessments emerged across the expedition period. A number of predictable correlations were identified between self-reported and linguistic assessments of affective/emotional experience. Overall, there was better agreement between self-reports and linguistic analytics for indicators of negative affect/emotion. Future research should build on this initial study to further test the links between self-reported affect and emotional states monitored via linguistics. This could help develop methods for monitoring psychological health in extreme environments and support organizational decision making. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  14. Advanced control and instrumentation systems in nuclear power plants. Design, verification and validation

    International Nuclear Information System (INIS)

    Haapanen, P.

    1995-01-01

    The Technical Committee Meeting on design, verification and validation of advanced control and instrumentation systems in nuclear power plants was held in Espoo, Finland on 20 - 23 June 1994. The meeting was organized by the International Atomic Energy Agency's (IAEA) International Working Group's (IWG) on Nuclear Power Plant Control and Instrumentation (NPPCI) and on Advanced Technologies for Water Cooled Reactors (ATWR). VTT Automation together with Imatran Voima Oy and Teollisuuden Voima Oy responded about the practical arrangements of the meeting. In total 96 participants from 21 countries and the Agency took part in the meeting and 34 full papers and 8 posters were presented. Following topics were covered in the papers: (1) experience with advanced and digital systems, (2) safety and reliability analysis, (3) advanced digital systems under development and implementation, (4) verification and validation methods and practices, (5) future development trends. (orig.)

  15. Development and design of a late-model fitness test instrument based on LabView

    Science.gov (United States)

    Xie, Ying; Wu, Feiqing

    2010-12-01

    Undergraduates are pioneers of China's modernization program and undertake the historic mission of rejuvenating our nation in the 21st century, whose physical fitness is vital. A smart fitness test system can well help them understand their fitness and health conditions, thus they can choose more suitable approaches and make practical plans for exercising according to their own situation. following the future trends, a Late-model fitness test Instrument based on LabView has been designed to remedy defects of today's instruments. The system hardware consists of fives types of sensors with their peripheral circuits, an acquisition card of NI USB-6251 and a computer, while the system software, on the basis of LabView, includes modules of user register, data acquisition, data process and display, and data storage. The system, featured by modularization and an open structure, is able to be revised according to actual needs. Tests results have verified the system's stability and reliability.

  16. Design requirements of instrumentation and control systems for next generation reactor

    International Nuclear Information System (INIS)

    Koo, In Soo; Lee, Byung Sun; Park, Kwang Hyun; Park, Heu Yoon; Lee, Dong Young; Kim, Jung Taek; Hwang, In Koo; Chung, Chul Hwan; Hur, Seop; Kim, Chang Hoi; Na, Nan Ju

    1994-03-01

    In this report, the basic design requirements of Instrumentation and Control systems for next generation reactor are described, which are top-tier level, to support the advanced I and C systems. It contains the requirements in accordance with the plant reliability, the plant performance, the operator's aid functions, the features for maintenance and testing, licensing issues for I and C systems. Advanced I and C systems are characterized such as the application of the digital and the human engineering technologies. To development of this requirements, the I and C systems for the foreign passive and the evolutionary types of reactor and the domestic conventional reators were reviewed and anlysed. At the detail design stage, these requirements will be used for top-tier requirements. To develop the detail design requirements in the future, more quantitive and qualitive analyses are need to be added. (Author) 44 refs

  17. Design of an instrument to measure the quality of care in Physical Therapy.

    Science.gov (United States)

    Cavalheiro, Leny Vieira; Eid, Raquel Afonso Caserta; Talerman, Claudia; Prado, Cristiane do; Gobbi, Fátima Cristina Martorano; Andreoli, Paola Bruno de Araujo

    2015-01-01

    To design an instrument composed of domains that would demonstrate physical therapy activities and generate a consistent index to represent the quality of care in physical therapy. The methodology Lean Six Sigma was used to design the tool. The discussion involved seven different management groups staff. By means of brainstorming and Cause & Effect Matrix, we set up the process map. Five requirements composed the quality of care index in physical therapy, after application of the tool called Cause & Effect Matrix. The following requirements were assessed: physical therapist performance, care outcome indicator, adherence to physical therapy protocols, measure whether the prognosis and treatment outcome was achieved and Infrastructure. The proposed design allowed evaluating several items related to physical therapy service, enabling customization, reproducibility and benchmarking with other organizations. For management, this index provides the opportunity to identify areas for improvement and the strengths of the team and process of physical therapy care.

  18. Design requirements of instrumentation and control systems for next generation reactor

    Energy Technology Data Exchange (ETDEWEB)

    Koo, In Soo; Lee, Byung Sun; Park, Kwang Hyun; Park, Heu Yoon; Lee, Dong Young; Kim, Jung Taek; Hwang, In Koo; Chung, Chul Hwan; Hur, Seop; Kim, Chang Hoi; Na, Nan Ju [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-03-01

    In this report, the basic design requirements of Instrumentation and Control systems for next generation reactor are described, which are top-tier level, to support the advanced I and C systems. It contains the requirements in accordance with the plant reliability, the plant performance, the operator`s aid functions, the features for maintenance and testing, licensing issues for I and C systems. Advanced I and C systems are characterized such as the application of the digital and the human engineering technologies. To development of this requirements, the I and C systems for the foreign passive and the evolutionary types of reactor and the domestic conventional reators were reviewed and anlysed. At the detail design stage, these requirements will be used for top-tier requirements. To develop the detail design requirements in the future, more quantitive and qualitive analyses are need to be added. (Author) 44 refs.

  19. Design, Modelling and Teleoperation of a 2 mm Diameter Compliant Instrument for the da Vinci Platform.

    Science.gov (United States)

    Francis, P; Eastwood, K W; Bodani, V; Looi, T; Drake, J M

    2018-05-07

    This work explores the feasibility of creating and accurately controlling an instrument for robotic surgery with a 2 mm diameter and a three degree-of-freedom (DoF) wrist which is compatible with the da Vinci platform. The instrument's wrist is composed of a two DoF bending notched-nitinol tube pattern, for which a kinematic model has been developed. A base mechanism for controlling the wrist is designed for integration with the da Vinci Research Kit. A basic teleoperation task is successfully performed using two of the miniature instruments. The performance and accuracy of the instrument suggest that creating and accurately controlling a 2 mm diameter instrument is feasible and the design and modelling proposed in this work provide a basis for future miniature instrument development.

  20. [Psychosocial work factors and self-reported health in the French national SUMER survey].

    Science.gov (United States)

    Lesuffleur, Thomas; Chastang, Jean-François; Cavet, Marine; Niedhammer, Isabelle

    2015-01-01

    This study was designed to investigate the associations between psychosocial work factors, using well-known theoretical models and emerging concepts, and self-reported health in the national population of French employees. This study was based on the data of the French national representative SUMER 2010 survey. The sample included 46,962 employees, 26,883 men and 20,079 women, with an 87% participation rate. Self-reported health was measured by means of a single question and was analysed as a binary variable. Psychosocial work factors included factors related to job strain and effort-reward imbalance models, workplace violence and working hours. Associations between psychosocial work factors and self-reported health were studied using weighted logistic regression models adjusted for covariates (age, occupation, economic activity, and other types of occupational exposure). Low decision latitude (skill discretion and decision authority), high psychological demands, low social support (from supervisors for men), low reward (low esteem and low job promotion for both genders and job insecurity for men), bullying and verbal abuse for both genders were associated with self-reported health. This study emphasizes the role of psychosocial work factors as risk factors for poor self-reported health and suggests that the implementation of preventive measures to reduce exposure to psychosocial work factors should be an objective for the improvement of health at work.

  1. The adolescent outcome of hyperactive girls: self-report of psychosocial status.

    Science.gov (United States)

    Young, Susan; Heptinstall, Ellen; Sonuga-Barke, Edmund J S; Chadwick, Oliver; Taylor, Eric

    2005-03-01

    The aim of the study was to clarify the developmental risk associated with hyperactive behaviour in girls in a longitudinal epidemiological design. This was investigated in a follow-up study of girls who were identified by parent and teacher ratings in a large community survey of 6- and 7-year-olds as showing pervasive hyperactivity or conduct problems or the comorbid mixture of both problems or neither problem. They were later investigated, at the age of 14 to 16 years, with a detailed self-report interview technique. Hyperactivity was a risk factor for later development, even allowing for the coexistence of conduct problems. Hyperactivity predicted academic problems and interpersonal relationship problems. Relationships with parents, by contrast, were not portrayed to be as problematic as relationships with peers and the opposite sex. Their psychological, social and occupational functioning was objectively rated to be more deviant and their self-report showed them to be more ambivalent about their future. There was a trend for hyperactivity to be self-reported as a risk for the development of continuing symptomatology but neither hyperactivity nor conduct problems were self-reported to be a risk for antisocial behaviour, substance misuse or low self-esteem in adolescence. However, they were at risk for the development of state anxiety. The results suggested girls' pattern of functioning may differ from that of boys because girls self-report a more pervasive range of social dysfunction than that previously reported in boys.

  2. Fear of crime and its relationship to self-reported health and stress among men

    Directory of Open Access Journals (Sweden)

    Gloria Macassa

    2018-01-01

    Design and Methods: The study used data collected from 2993 men through a cross sectional survey in the 2014 Health in Equal Terms survey. Descriptive and logistic regression analyses were carried out to study the relationship between fear of crime and self-reported health and stress. Results: There was a statistically significant association between fear of crime and self-reported poor health and stress among men residing in Gävleborg County. In the bivariate analysis, men who reported fear of crime had odds of 1.98 (CI 1.47- 2.66 and 2.23 (CI 1.45-3.41 respectively. Adjusting for demographic, social and economic variables in the multivariate analysis only reduced the odds ratio for self-reported poor health to 1.52 (CI 1.05-2.21 but not for self-reported stress with odds of 2.22 (1.27-3.86. Conclusions: Fear of crime among men was statistically significantly associated with self-reported poor health and stress in Gävleborg County. However, the statistically significant relationship remained even after accounting for demographic, social and economic factors, which warrants further research to better understand the role played by other variables.

  3. [Design and implementation of real-time continuous glucose monitoring instrument].

    Science.gov (United States)

    Huang, Yonghong; Liu, Hongying; Tian, Senfu; Jia, Ziru; Wang, Zi; Pi, Xitian

    2017-12-01

    Real-time continuous glucose monitoring can help diabetics to control blood sugar levels within the normal range. However, in the process of practical monitoring, the output of real-time continuous glucose monitoring system is susceptible to glucose sensor and environment noise, which will influence the measurement accuracy of the system. Aiming at this problem, a dual-calibration algorithm for the moving-window double-layer filtering algorithm combined with real-time self-compensation calibration algorithm is proposed in this paper, which can realize the signal drift compensation for current data. And a real-time continuous glucose monitoring instrument based on this study was designed. This real-time continuous glucose monitoring instrument consisted of an adjustable excitation voltage module, a current-voltage converter module, a microprocessor and a wireless transceiver module. For portability, the size of the device was only 40 mm × 30 mm × 5 mm and its weight was only 30 g. In addition, a communication command code algorithm was designed to ensure the security and integrity of data transmission in this study. Results of experiments in vitro showed that current detection of the device worked effectively. A 5-hour monitoring of blood glucose level in vivo showed that the device could continuously monitor blood glucose in real time. The relative error of monitoring results of the designed device ranged from 2.22% to 7.17% when comparing to a portable blood meter.

  4. Conceptual design of wearpack with physiology detector feature based on wearable instrumentation

    Science.gov (United States)

    Sukirman, Melani; Laksono, Pringgo Widyo; Priadythama, Ilham; Susmartini, Susy; Suhardi, Bambang

    2017-11-01

    Every company in Indonesia is responsible for their worker health and safety condition as mentioned in UU No I year 1970. In manufacturing industries, there are many manual tasks dealing with high work load and risk, so that they require excellent concentration and physical condition. There is no ideal way to guarantee worker safety without a real time physiological monitoring. This paper reports our ongoing study in conceptual design development of worker's clothing which is equipped with a wearable instrumentation system. The system is designed to detect and measure body temperature and pulse in real time. Some electrical components such as, LCD (liquid crystal display), LEDs (light emitting diode), batteries, and physiological sensors were assembled. All components are controlled by a wearable on board controller. LEDs is used as alert which can indicate abnormal physical conditions. The LCD was added to provide more detail information. TMP 36 and XD-58C were selected as the physiological sensors. Finally, an Arduino Lilypad was chosen for the controller. This instrumentation system was verified by accurately detected and inform physiological condition of 3 subjects. Further we are going to attach the system to a worker's clothing which was specifically designed to simplify and comfortable usage.

  5. Design and evaluation of an architecture for a digital signal processor for instrumentation applications

    Science.gov (United States)

    Fellman, Ronald D.; Kaneshiro, Ronald T.; Konstantinides, Konstantinos

    1990-03-01

    The authors present the design and evaluation of an architecture for a monolithic, programmable, floating-point digital signal processor (DSP) for instrumentation applications. An investigation of the most commonly used algorithms in instrumentation led to a design that satisfies the requirements for high computational and I/O (input/output) throughput. In the arithmetic unit, a 16- x 16-bit multiplier and a 32-bit accumulator provide the capability for single-cycle multiply/accumulate operations, and three format adjusters automatically adjust the data format for increased accuracy and dynamic range. An on-chip I/O unit is capable of handling data block transfers through a direct memory access port and real-time data streams through a pair of parallel I/O ports. I/O operations and program execution are performed in parallel. In addition, the processor includes two data memories with independent addressing units, a microsequencer with instruction RAM, and multiplexers for internal data redirection. The authors also present the structure and implementation of a design environment suitable for the algorithmic, behavioral, and timing simulation of a complete DSP system. Various benchmarking results are reported.

  6. Congenital cerebral palsy and prenatal exposure to self-reported maternal infections, fever, or smoking

    DEFF Research Database (Denmark)

    Streja, Elani; Miller, Jessica; Bech, Bodil H

    2013-01-01

    OBJECTIVE: The objective of the study was to investigate the association between maternal self-reported infections, fever, and smoking in the prenatal period and the subsequent risk for congenital cerebral palsy (CP). STUDY DESIGN: We included the 81,066 mothers of singletons born between 1996...... and midgestation. We identified 139 CP cases including 121 cases of spastic CP (sCP) as confirmed by the Danish National Cerebral Palsy Register. Cox proportional hazards regression models were used to estimate adjusted hazard ratios (aHRs) and 95% confidence intervals (CIs). RESULTS: Self-reported vaginal...

  7. Detecting Careless Responses to Self-Reported Questionnaires

    Science.gov (United States)

    Kountur, Ronny

    2016-01-01

    Problem Statement: The use of self-report questionnaires may lead to biases such as careless responses that distort the research outcomes. Early detection of careless responses in self-report questionnaires may reduce error, but little guidance exists in the literature regarding techniques for detecting such careless or random responses in…

  8. Validation of Self-Reported Cognitive Problems with Objective ...

    Science.gov (United States)

    There is a lack of validation of self-reported cognitive problems with objective neuropsychological measures. The validity of four self-reported cognitive items from a health questionnaire (HQ) and the Symptoms Checklist 90-Revised (SCL-90-R) was examined with objective clinical neuropsychological test performance in 147 manganese (Mn) exposed residents. These residents were from two Ohio towns exposed to ambient air-Mn from an industrial source with modeled average air-Mn concentrations of 0.54 µg/m3 (range: 0.01-4.58) and were part of a larger study of cognitive, motor, tremor abnormalities and their relationship to Mn exposure.The primarily white (94.6%) participants (aged 30-64) lived in the towns for at least 10 years (range: 10-64) and had 13.9 years of education, on average. In the last 7 days before testing, 94 (64.4%) participants self-reported concentration problems and 105 (71.8%) self-reported memory problems. After adjusting for age and education, participants who self-reported cognitive problems did not perform worse on the objective neuropsychological measures than those who reported not having problems, except on 1 of 17 neuropsychological tests (Stroop Color). Greater levels of depression and female sex predicted having more self-reported cognitive problems. Higher education was associated with fewer self-reported cognitive problems. Measures of Mn in air, blood, hair, and toenails were not associated with subjective cognitive self-reported p

  9. Prevalence and Correlates of Self-Reported ADHD Symptoms in Children Attending School in India.

    Science.gov (United States)

    Jaisoorya, T S; Beena, K V; Beena, M; Ellangovan, K; George, Sanju; Thennarasu, K; Srinath, Shoba

    2016-09-02

    To study the prevalence and correlates of self-reported ADHD symptoms among school-going adolescents from Kerala, India. Seven thousand five hundred sixty students from Classes 8, 10, and 12, aged 12 to 19 years, across 73 schools selected by cluster random sampling, were invited to participate, but only 7,150 successfully completed the questionnaire incorporating standardized instruments. Three hundred five (4.3%) self-reported symptoms for ADHD combined type, 131 (1.8%) for ADHD hyperactive-impulsive type, and 102 (1.4%) for ADHD inattentive type with a male predominance. Binary logistic regression analysis showed that those with symptoms of ADHD (combined type) compared with the non-ADHD group had poorer academic performance, significantly higher substance use, psychological distress, suicidality, and sexual abuse. The high prevalence of self-reported ADHD symptoms and its association with negative correlates previously reported in literature in those with a diagnosis of ADHD suggests that clinically significant self-reported ADHD symptoms could be as disabling as ADHD. © The Author(s) 2016.

  10. Self-reported quality of ADL task performance among patients with COPD exacerbations.

    Science.gov (United States)

    Bendixen, Hans Jørgen; Wæhrens, Eva Ejlersen; Wilcke, Jon Torgny; Sørensen, Lisbeth Villemoes

    2014-07-01

    Patients suffering from chronic obstructive pulmonary disease (COPD) experience problems in the performance of activities of daily living (ADL) tasks. The objective was to examine the self-reported quality of ADL task performance among COPD patients, and to investigate whether age, gender, and routine COPD characteristics correlate with the self-reported ADL ability. Eighty patients admitted to hospital with COPD exacerbations participated. In a cross-sectional study, the patients' self-reported ADL ability was assessed using the ADL-Interview (ADL-I) instrument. Data concerning age, gender, and routine COPD characteristics were drawn from the patients' medical records. The patients reported being inefficient to markedly inefficient when performing ADL tasks within the personal hygiene, toileting, dressing, household, mobility, and transportation domains. While more than 90% of the participants reported increased effort and/or fatigue when performing the ADL tasks, up to 88% of the participants relied on help from others in the performance of general household chores like cooking and shopping. Self-reported ADL ability did not correlate with age, gender, or routine COPD characteristics. Decreased quality of ADL task performance seemed to be extremely common among COPD patients. Therefore, addressing the problems in individually tailored pulmonary rehabilitation programmes may be advantageous.

  11. Designing means and specifications for model FT-619 kidney function instrument

    International Nuclear Information System (INIS)

    Yu Yongding

    1988-04-01

    In this paper, it is pointed out that the model FT-619 Kidney Function Equipment is a new cost-effective nuclear medicine instrument, which takes the leading position in China. The performance of the model FT-619,especially the lead collimated scintillation detector has reached the same level as the advanced equipment in the world market. It is also described in this article in detail that the design of the lead collimator and the shielding as well as the detection efficiency have achieved the optimum level and that a comparison has been made with foreign products

  12. Using the Rasch measurement model to design a report writing assessment instrument.

    Science.gov (United States)

    Carlson, Wayne R

    2013-01-01

    This paper describes how the Rasch measurement model was used to develop an assessment instrument designed to measure student ability to write law enforcement incident and investigative reports. The ability to write reports is a requirement of all law enforcement recruits in the state of Michigan and is a part of the state's mandatory basic training curriculum, which is promulgated by the Michigan Commission on Law Enforcement Standards (MCOLES). Recently, MCOLES conducted research to modernize its training and testing in the area of report writing. A structured validation process was used, which included: a) an examination of the job tasks of a patrol officer, b) input from content experts, c) a review of the professional research, and d) the creation of an instrument to measure student competency. The Rasch model addressed several measurement principles that were central to construct validity, which were particularly useful for assessing student performances. Based on the results of the report writing validation project, the state established a legitimate connectivity between the report writing standard and the essential job functions of a patrol officer in Michigan. The project also produced an authentic instrument for measuring minimum levels of report writing competency, which generated results that are valid for inferences of student ability. Ultimately, the state of Michigan must ensure the safety of its citizens by licensing only those patrol officers who possess a minimum level of core competency. Maintaining the validity and reliability of both the training and testing processes can ensure that the system for producing such candidates functions as intended.

  13. Design of analytical instrumentation with D-T sealed neutron generators

    International Nuclear Information System (INIS)

    Qiao Yahua; Wu Jizong; Zheng Weiming; Liu Quanwei; Zhang Min

    2008-01-01

    Analytical instrumentation with D-T sealed neutron generators source activation, The 14 MeV D-T sealed neutron tube with 10 9 n · s -1 neutron yield is used as generator source. The optimal structure of moderator and shield was achieved by MC computing.The instrumentation's configuration is showed. The instrumentation is made up of the SMY-DT50.8-2.1 sealed neutron tube and the high-voltage power supply system, which center is the sealed neutron generators. 6 cm Pb and 20 cm polythene is chosen as moderator, Pb, polythene and 10 cm boron-PE was chosen as shield .The sample box is far the source from 9 cm, the measurement system were made up of HPGe detector and the sample transforming system. After moderator and shield, the thermal neutron fluence rate at the point of sample is 0.93 × 10 6 n · s -1 cm -2 , which is accorded with design demand, and the laboratory and surroundings reaches the safety standard of the dose levels. (authors)

  14. Quantitative imaging of the human upper airway: instrument design and clinical studies

    Science.gov (United States)

    Leigh, M. S.; Armstrong, J. J.; Paduch, A.; Sampson, D. D.; Walsh, J. H.; Hillman, D. R.; Eastwood, P. R.

    2006-08-01

    Imaging of the human upper airway is widely used in medicine, in both clinical practice and research. Common imaging modalities include video endoscopy, X-ray CT, and MRI. However, no current modality is both quantitative and safe to use for extended periods of time. Such a capability would be particularly valuable for sleep research, which is inherently reliant on long observation sessions. We have developed an instrument capable of quantitative imaging of the human upper airway, based on endoscopic optical coherence tomography. There are no dose limits for optical techniques, and the minimally invasive imaging probe is safe for use in overnight studies. We report on the design of the instrument and its use in preliminary clinical studies, and we present results from a range of initial experiments. The experiments show that the instrument is capable of imaging during sleep, and that it can record dynamic changes in airway size and shape. This information is useful for research into sleep disorders, and potentially for clinical diagnosis and therapies.

  15. Design and validation of a standards-based science teacher efficacy instrument

    Science.gov (United States)

    Kerr, Patricia Reda

    National standards for K--12 science education address all aspects of science education, with their main emphasis on curriculum---both science subject matter and the process involved in doing science. Standards for science teacher education programs have been developing along a parallel plane, as is self-efficacy research involving classroom teachers. Generally, studies about efficacy have been dichotomous---basing the theoretical underpinnings on the work of either Rotter's Locus of Control theory or on Bandura's explanations of efficacy beliefs and outcome expectancy. This study brings all three threads together---K--12 science standards, teacher education standards, and efficacy beliefs---in an instrument designed to measure science teacher efficacy with items based on identified critical attributes of standards-based science teaching and learning. Based on Bandura's explanation of efficacy being task-specific and having outcome expectancy, a developmental, systematic progression from standards-based strategies and activities to tasks to critical attributes was used to craft items for a standards-based science teacher efficacy instrument. Demographic questions related to school characteristics, teacher characteristics, preservice background, science teaching experience, and post-certification professional development were included in the instrument. The instrument was completed by 102 middle level science teachers, with complete data for 87 teachers. A principal components analysis of the science teachers' responses to the instrument resulted in two components: Standards-Based Science Teacher Efficacy: Beliefs About Teaching (BAT, reliability = .92) and Standards-Based Science Teacher Efficacy: Beliefs About Student Achievement (BASA, reliability = .82). Variables that were characteristic of professional development activities, science content preparation, and school environment were identified as members of the sets of variables predicting the BAT and BASA

  16. A Cross-Cultural Study of Self-Report Depressive Symptoms among College Students.

    Science.gov (United States)

    Crittenden, Kathleen S.; And Others

    1992-01-01

    A study of self-report depressive symptoms measured by the Zung Self-Rating Depression Scale was conducted in Korea, the Philippines, Taiwan, and the United States with 953 college students. There are marked differences among countries in symptoms reported. Research designs and measurement strategies for cross-cultural research are discussed. (SLD)

  17. Does Negative Mood Influence Self-Report Assessment of Individual and Relational Measures? An Experimental Analysis

    Science.gov (United States)

    Heene, Els; De Raedt, Rudi; Buysse, Ann; Van Oost, Paulette

    2007-01-01

    The present study was designed to test the influence of negative mood on the self-report of individual and relational correlates of depression and marital distress. The authors applied a combined experimental mood induction procedure, based on music, autobiographical recall, and environmental manipulation. Results showed that the mood manipulation…

  18. Self-Reported Health among Older Bangladeshis: How Good a Health Indicator Is It?

    Science.gov (United States)

    Rahman, M. Omar; Barsky, Arthur J.

    2003-01-01

    Purpose: This study examines the value of self-reported health (SRH) as an indicator of underlying health status in a developing country setting. Design and Methods: Logistic regression methods with adjustments for multistage sampling are used to examine the factors associated with SRH in 2,921 men and women aged 50 and older in rural Bangladesh.…

  19. Prevalence of self-reported food hypersensitivity among school children in The Netherlands

    NARCIS (Netherlands)

    Brugman, E.; Meulmeester, J.F.; Spee-Wekke, A. van der; Beuker, R.J.; Radder, J.J.; Verloove-Vanhorick, S.P.

    1998-01-01

    Objectives: To provide national figures on the prevalence of self-reported food hypersensitivity (S-FH), and the association with socio-demographic variables and some health indicators in schoolchildren in The Netherlands. Design: As part of the Child Health Monitoring System, data were collected

  20. Content and Language Integrated Learning in the Netherlands: Teachers' Self-Reported Pedagogical Practices

    Science.gov (United States)

    van Kampen, Evelyn; Admiraal, Wilfried; Berry, Amanda

    2018-01-01

    In recent years, a surging uptake of content and language integrated learning (CLIL) has permeated the European context. This article presents the outcomes of a study about the self-reported pedagogical practices of CLIL teachers in the Netherlands. To investigate these teachers' pedagogies, a questionnaire was designed, validated and,…

  1. Technical Analysis of Scores on the "Self-Efficacy Self-Report Scale"

    Science.gov (United States)

    Erford, Bradley T.; Schein, Hallie; Duncan, Kelly

    2011-01-01

    The purpose of this study was to provide preliminary analysis of reliability and validity of scores on the "Self-Efficacy Self-Report Scale", which was designed to assess general self-efficacy in students aged 10 to 17 years. Confirmatory factor analysis on cross-validated samples was conducted revealing a marginal fit of the data to the…

  2. Self-Report of Depressive Symptoms in Low Back Pain Patients.

    Science.gov (United States)

    Crisson, James; And Others

    1986-01-01

    Presents two studies designed to examine the self-report of depressive symptoms in low back pain patients (N=134). Both studies found that patients were more likely to report somatic than cognitive symptoms of depression. Patients with multiple physical findings were not more likely to report somatic symptoms than patients with few physical…

  3. Parenting Young Children (PARYC): Validation of a Self-Report Parenting Measure

    Science.gov (United States)

    McEachern, Amber D.; Dishion, Thomas J.; Weaver, Chelsea M.; Shaw, Daniel S.; Wilson, Melvin N.; Gardner, Frances

    2012-01-01

    The measurement of parenting behaviors is important to the field of psychology and the goal of remediating problematic parenting as a means of reducing child problem behaviors. The Parenting Young Children (PARYC) is a self-report measure designed to address parenting behaviors relevant for the caregivers of young children, and was assessed in…

  4. Association between chronic urticaria and self-reported penicillin allergy.

    Science.gov (United States)

    Silverman, Susanna; Localio, Russell; Apter, Andrea J

    2016-04-01

    Penicillin allergy is the most commonly reported drug allergy and often presents with cutaneous symptoms. Other common diagnoses, such as chronic urticaria, may be falsely attributed to penicillin allergy. Because chronic urticaria is fairly common in the general population, evaluation of its prevalence in patients with self-reported penicillin allergy was of interest. Similarly, the prevalence of self-reported penicillin allergy in patients with chronic urticaria is not well known and also becomes interesting in light of the high prevalence of self-reported penicillin allergy in the general population. To determine the prevalence of self-reported penicillin allergy in patients with chronic urticaria and the prevalence of chronic urticaria in patients with self-reported penicillin allergy. This was a retrospective medical record review of 11,143 patients completed using the electronic health record of the University of Pennsylvania Allergy and Immunology clinic. The prevalence of self-reported penicillin allergy in patients with chronic urticaria was found to be approximately 3 times greater than in the general population. The prevalence of chronic urticaria in patients with self-reported penicillin allergy was also found to be approximately 3 times greater than in the population. This link between chronic urticaria and self-reported penicillin allergy highlights the need for clinicians to inquire about self-reported penicillin allergy in patients with chronic urticaria and to consider penicillin skin testing. Furthermore, patients who report penicillin allergy might actually have chronic urticaria, indicating the importance of inquiring about chronic urticaria symptoms in patients with self-reported penicillin allergy. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  5. Passive Tomography for Spent Fuel Verification: Analysis Framework and Instrument Design Study

    Energy Technology Data Exchange (ETDEWEB)

    White, Timothy A.; Svard, Staffan J.; Smith, Leon E.; Mozin, Vladimir V.; Jansson, Peter; Davour, Anna; Grape, Sophie; Trellue, H.; Deshmukh, Nikhil S.; Wittman, Richard S.; Honkamaa, Tapani; Vaccaro, Stefano; Ely, James

    2015-05-18

    The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly is being assessed through a collaboration of Support Programs to the International Atomic Energy Agency (IAEA). In the first phase of this study, two safeguards verification objectives have been identified. The first is the independent determination of the number of active pins that are present in the assembly, in the absence of a priori information. The second objective is to provide quantitative measures of pin-by-pin properties, e.g. activity of key isotopes or pin attributes such as cooling time and relative burnup, for the detection of anomalies and/or verification of operator-declared data. The efficacy of GET to meet these two verification objectives will be evaluated across a range of fuel types, burnups, and cooling times, and with a target interrogation time of less than 60 minutes. The evaluation of GET viability for safeguards applications is founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types are used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. Instrument response data are processed by a variety of tomographic-reconstruction and image-processing methods, and scoring metrics specific to each of the verification objectives are defined and used to evaluate the performance of the methods. This paper will provide a description of the analysis framework and evaluation metrics, example performance-prediction results, and describe the design of a “universal” GET instrument intended to support the full range of verification scenarios envisioned by the IAEA.

  6. Concept design of multipurpose gamma irradiator ISG-500 instrumentation and control system

    International Nuclear Information System (INIS)

    Dian F Atmoko; Sutomo B; Ikhsan S; A Suntoro

    2010-01-01

    Has been concept designed of multipurpose 2 x 250 kCi gamma irradiator instrumentation and control system (ICS). The problem in ICS of irradiator is How to get similar of dose rate and start-up/shut down mechanism with highest safety factor. The concept designed of ICS had of tree parameter such as safety, operation and security. The tree of parameter used to start-up and shut-down in irradiator installation with interlock system connection to guarantee of safety. Similar of dose rate obtained by controlled of exposure time witch stopped of carrier conveyor in point of stopped carrier and for delay time, with speed of moved motor carrier to set in constant speed. (author)

  7. Designing Financial Instruments for Rapid Flood Response Using Remote Sensed and Archival Hazard and Exposure Information

    Science.gov (United States)

    Lall, U.; Allaire, M.; Ceccato, P.; Haraguchi, M.; Cian, F.; Bavandi, A.

    2017-12-01

    Catastrophic floods can pose a significant challenge for response and recovery. A key bottleneck in the speed of response is the availability of funds to a country or regions finance ministry to mobilize resources. Parametric instruments, where the release of funs is tied to the exceedance of a specified index or threshold, rather than to loss verification are well suited for this purpose. However, designing and appropriate index, that is not subject to manipulation and accurately reflects the need is a challenge, especially in developing countries which have short hydroclimatic and loss records, and where rapid land use change has led to significant changes in exposure and hydrology over time. The use of long records of rainfall from climate re-analyses, flooded area and land use from remote sensing to design and benchmark a parametric index considering the uncertainty and representativeness of potential loss is explored with applications to Bangladesh and Thailand. Prospects for broader applicability and limitations are discussed.

  8. Safari: instrument design of the far-infrared imaging spectrometer for spica

    Science.gov (United States)

    Jellema, W.; Pastor, C.; Naylor, D.; Jackson, B.; Sibthorpe, B.; Roelfsema, P.

    2017-11-01

    The next great leap forward in space-based far-infrared astronomy will be made by the Japanese-led SPICA mission, which is anticipated to be launched late 2020's as the next large astrophysics mission of JAXA, in partnership with ESA and with key European contributions. Filling in the gap between JWST and ALMA, the SPICA mission will study the evolution of galaxies, stars and planetary systems. SPICA will utilize a deeply cooled 3m-class telescope, provided by European industry, to realize zodiacal background limited performance, high spatial resolution and large collecting area. Making full advantage of the deeply cooled telescope (architecture. We will describe the reference design of the SAFARI focal- plane unit, the implementation of the various optical instrument functions designed around the central large-stroke FTS system, the photometric band definition and out-of-band filtering by quasioptical elements, the control of straylight, diffraction and thermal emission in the long-wavelength limit, and how we interface to the large-format FPA arrays at one end and the SPICA telescope assembly at the other end. We will briefly discuss the key performance drivers with special emphasis on the optical techniques adopted to overcome issues related to very low background operation of SAFARI. A summary and discussion of the expected instrument performance and an overview of the astronomical capabilities finally conclude the paper.

  9. Minimizing Experimental Setup Time and Effort at APS beamline 1-ID through Instrumentation Design

    Energy Technology Data Exchange (ETDEWEB)

    Benda, Erika; Almer, Jonathan; Kenesei, Peter; Mashayekhi, Ali; Okasinksi, John; Park, Jun-Sang; Ranay, Rogelio; Shastri, Sarvijt

    2016-01-01

    Sector 1-ID at the APS accommodates a number of dif-ferent experimental techniques in the same spatial enve-lope of the E-hutch end station. These include high-energy small and wide angle X-ray scattering (SAXS and WAXS), high-energy diffraction microscopy (HEDM, both near and far field modes) and high-energy X-ray tomography. These techniques are frequently combined to allow the users to obtain multimodal data, often attaining 1 μm spatial resolution and <0.05º angular resolution. Furthermore, these techniques are utilized while the sam-ple is thermo-mechanically loaded to mimic real operat-ing conditions. The instrumentation required for each of these techniques and environments has been designed and configured in a modular way with a focus on stability and repeatability between changeovers. This approach allows the end station to be more versatile, capable of collecting multi-modal data in-situ while reducing time and effort typically required for set up and alignment, resulting in more efficient beam time use. Key instrumentation de-sign features and layout of the end station are presented.

  10. A new aberration-corrected, energy-filtered LEEM/PEEM instrument. I. Principles and design

    International Nuclear Information System (INIS)

    Tromp, R.M.; Hannon, J.B.; Ellis, A.W.; Wan, W.; Berghaus, A.; Schaff, O.

    2010-01-01

    We describe a new design for an aberration-corrected low energy electron microscope (LEEM) and photo electron emission microscope (PEEM), equipped with an in-line electron energy filter. The chromatic and spherical aberrations of the objective lens are corrected with an electrostatic electron mirror that provides independent control over the chromatic and spherical aberration coefficients C c and C 3 , as well as the mirror focal length, to match and correct the aberrations of the objective lens. For LEEM (PEEM) the theoretical resolution is calculated to be ∼1.5 nm (∼4 nm). Unlike previous designs, this instrument makes use of two magnetic prism arrays to guide the electron beam from the sample to the electron mirror, removing chromatic dispersion in front of the mirror by symmetry. The aberration correction optics was retrofitted to an uncorrected instrument with a base resolution of 4.1 nm in LEEM. Initial results in LEEM show an improvement in resolution to ∼2 nm.

  11. Mechanical Design of NESSI: New Mexico Tech Extrasolar Spectroscopic Survey Instrument

    Science.gov (United States)

    Santoro, Fernando G.; Olivares, Andres M.; Salcido, Christopher D.; Jimenez, Stephen R.; Jurgenson, Colby A.; Hrynevych, Michael A.; Creech-Eakman, Michelle J.; Boston, Penny J.; Schmidt, Luke M.; Bloemhard, Heather; hide

    2011-01-01

    NESSI: the New Mexico Tech Extrasolar Spectroscopic Survey Instrument is a ground-based multi-object spectrograph that operates in the near-infrared. It will be installed on one of the Nasmyth ports of the Magdalena Ridge Observatory (MRO) 2.4-meter Telescope sited in the Magdalena Mountains, about 48 km west of Socorro-NM. NESSI operates stationary to the telescope fork so as not to produce differential flexure between internal opto-mechanical components during or between observations. An appropriate mechanical design allows the instrument alignment to be highly repeatable and stable for both short and long observation timescales, within a wide-range of temperature variation. NESSI is optically composed of a field lens, a field de-rotator, re-imaging optics, an auto-guider and a Dewar spectrograph that operates at LN2 temperature. In this paper we report on NESSI's detailed mechanical and opto-mechanical design, and the planning for mechanical construction, assembly, integration and verification.

  12. The opto-mechanical design for GMOX: a next-generation instrument concept for Gemini

    Science.gov (United States)

    Smee, Stephen A.; Barkhouser, Robert; Robberto, Massimo; Ninkov, Zoran; Gennaro, Mario; Heckman, Timothy M.

    2016-08-01

    We present the opto-mechanical design of GMOX, the Gemini Multi-Object eXtra-wide-band spectrograph, a potential next-generation (Gen-4 #3) facility-class instrument for Gemini. GMOX is a wide-band, multi-object, spectrograph with spectral coverage spanning 350 nm to 2.4 um with a nominal resolving power of R 5000. Through the use of Digital Micromirror Device (DMD) technology, GMOX will be able to acquire spectra from hundreds of sources simultaneously, offering unparalleled flexibility in target selection. Utilizing this technology, GMOX can rapidly adapt individual slits to either seeing-limited or diffraction-limited conditions. The optical design splits the bandpass into three arms, blue, red, and near infrared, with the near-infrared arm being split into three channels covering the Y+J band, H band, and K band. A slit viewing camera in each arm provides imaging capability for target acquisition and fast-feedback for adaptive optics control with either ALTAIR (Gemini North) or GeMS (Gemini South). Mounted at the Cassegrain focus, GMOX is a large (1.3 m x 2.8 m x 2.0 m) complex instrument, with six dichroics, three DMDs (one per arm), five science cameras, and three acquisition cameras. Roughly half of these optics, including one DMD, operate at cryogenic temperature. To maximize stiffness and simplify assembly and alignment, the opto-mechanics are divided into three main sub-assemblies, including a near-infrared cryostat, each having sub-benches to facilitate ease of alignment and testing of the optics. In this paper we present the conceptual opto-mechanical design of GMOX, with an emphasis on the mounting strategy for the optics and the thermal design details related to the near-infrared cryostat.

  13. Design of the high resolution optical instrument for the Pleiades HR Earth observation satellites

    Science.gov (United States)

    Lamard, Jean-Luc; Gaudin-Delrieu, Catherine; Valentini, David; Renard, Christophe; Tournier, Thierry; Laherrere, Jean-Marc

    2017-11-01

    As part of its contribution to Earth observation from space, ALCATEL SPACE designed, built and tested the High Resolution cameras for the European intelligence satellites HELIOS I and II. Through these programmes, ALCATEL SPACE enjoys an international reputation. Its capability and experience in High Resolution instrumentation is recognised by the most customers. Coming after the SPOT program, it was decided to go ahead with the PLEIADES HR program. PLEIADES HR is the optical high resolution component of a larger optical and radar multi-sensors system : ORFEO, which is developed in cooperation between France and Italy for dual Civilian and Defense use. ALCATEL SPACE has been entrusted by CNES with the development of the high resolution camera of the Earth observation satellites PLEIADES HR. The first optical satellite of the PLEIADES HR constellation will be launched in mid-2008, the second will follow in 2009. To minimize the development costs, a mini satellite approach has been selected, leading to a compact concept for the camera design. The paper describes the design and performance budgets of this novel high resolution and large field of view optical instrument with emphasis on the technological features. This new generation of camera represents a breakthrough in comparison with the previous SPOT cameras owing to a significant step in on-ground resolution, which approaches the capabilities of aerial photography. Recent advances in detector technology, optical fabrication and electronics make it possible for the PLEIADES HR camera to achieve their image quality performance goals while staying within weight and size restrictions normally considered suitable only for much lower performance systems. This camera design delivers superior performance using an innovative low power, low mass, scalable architecture, which provides a versatile approach for a variety of imaging requirements and allows for a wide number of possibilities of accommodation with a mini

  14. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  15. A Composite Self-Report: Reasons for Taking Science Courses as Given by Cocoa High School Science Students.

    Science.gov (United States)

    Louwerse, Frances H.

    A self-report instrument (questionnaire/reaction scale) was developed and administered to students in grades 9-12 to: (1) determine the number of science courses taken by each grade level; (2) estimate the number of science courses requested for future years and indicate where recruitment efforts would be needed; (3) examine other-directed reasons…

  16. How Are Learning Strategies Reflected in the Eyes? Combining Results from Self-Reports and Eye-Tracking

    Science.gov (United States)

    Catrysse, Leen; Gijbels, David; Donche, Vincent; De Maeyer, Sven; Lesterhuis, Marije; Van den Bossche, Piet

    2018-01-01

    Background: Up until now, empirical studies in the Student Approaches to Learning field have mainly been focused on the use of self-report instruments, such as interviews and questionnaires, to uncover differences in students' general preferences towards learning strategies, but have focused less on the use of task-specific and online measures.…

  17. Self-reported Discrimination and Depressive Symptoms Among Older Chinese Adults in Chicago.

    Science.gov (United States)

    Li, Lydia W; Dong, XinQi

    2017-07-01

    Discrimination is part of life for many Americans, especially ethnic minorities. Focusing on older Chinese Americans, this study examines the association between self-reported discrimination and depressive symptoms and identifies subgroups that are more likely to report experiencing discrimination. We conducted cross-sectional analysis of data collected from adults (age 60+ years) of Chinese origin residing in the Greater Chicago area (N = 3,004). Self-reported discrimination was assessed by the Experiences of Discrimination instrument and was dichotomized (yes vs no). Depressive symptoms were measured by the Patient Health Questionnaire (PHQ-9). Logistic regression of self-reported discrimination and negative binominal regression of depressive symptoms were conducted. About 21.5% of the sample reported having experienced discrimination. The odds of reporting discrimination are higher for those who are younger, have higher education and income, are more acculturated, have been in the United States longer, live outside Chinatown, and have higher levels of neuroticism and conscientiousness. Self-reported discrimination is significantly and positively associated with depressive symptoms, independent of sociodemographic characteristics, migration-related variables, and personality factors. Findings suggest a robust relationship between self-reported discrimination and depressive symptoms in older Chinese Americans. They further suggest that the relatively advantaged groups-younger, higher socioeconomic status, more acculturated, and living outside Chinatown-are more likely to report experiencing discrimination. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Screening for oropharyngeal dysphagia in older adults: A systematic review of self-reported questionnaires.

    Science.gov (United States)

    Magalhães Junior, Hipólito V; Pernambuco, Leandro de Araújo; Lima, Kenio C; Ferreira, Maria Angela F

    2018-04-03

    Oropharyngeal dysphagia is a swallowing disorder with signs and symptoms which may be present in older adults, but they are rarely noticed as a health concern by older people. The earliest possible identification of this clinical condition is needed by self-reported population-based screening questionnaire, which are valid and reliable for preventing risks to nutritional status, increased morbidity and mortality. The aim of this systematic review was to identify self-reported screening questionnaires for oropharyngeal dysphagia in older adults to evaluate their methodological quality for population-based studies. An extensive search of electronic databases (PubMed (MEDLINE), Ovid MEDLINE(R), Scopus, Cochrane Library, CINAHL, Web of Science (WOS), PsycINFO (APA), Lilacs and Scielo) was conducted in the period from April to May 2017 using previously established search strategies by the two evaluators. The methodological quality and the psychometric properties of the included studies were evaluated by the COSMIN (Consensus based Standards for the selection of health Measurement Instruments) checklist and the quality criteria of Terwee and colleagues, respectively. The analysed information was extracted from three articles which had conducted studies on the prevalence of oropharyngeal dysphagia by self-reported screening questionnaires, showing poor methodological quality and flaws in the methodological description to demonstrate its psychometric properties. This study did not find any self-reported screening questionnaires for oropharyngeal dysphagia with suitable methodological quality and appropriate evidence in its psychometric properties for elders. Therefore, the self-reported questionnaires within the diagnostic proposal require greater details in its process for obtaining valid and reliable evidence. © 2018 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  19. Predictors of self-reported academic performance among undergraduate medical students of Hawassa University, Ethiopia.

    Science.gov (United States)

    Gedefaw, Abel; Tilahun, Birkneh; Asefa, Anteneh

    2015-01-01

    This study was conducted to identify predictors of self-reported academic performance in undergraduate medical students at Hawassa University. An analytical cross-sectional study involving 592 undergraduate medical students was conducted in November 2012. The academic performance of the study subjects was measured by self-reported cumulative grade point average (GPA) using a self-administered questionnaire. Data were entered and analyzed using Statistical Package for the Social Sciences version 16 software. Pearson's bivariate correlations, multiple linear regression, and multiple logistic regression were used to identify predictors of academic performance. The self-reported academic performance of students had been decreasing as the academic years progressed, with the highest and lowest performance being in the premedicine (mean GPA 3.47) and clinical I (mean GPA 2.71) years, respectively. One hundred and fifty-eight (26.7%) of the participants had ever been delayed, 37 (6.2%) had ever re-sat for examination, and two (0.3%) had ever been warned due to academic failure. The overall variation in self-reported academic performance of the students was 32.8%. Participant age alone explained 21.9% of the variation. On the other hand, university entrance examination results, substance use at university, and medicine as first choice by students were identified as predictors of variation in self-reported academic performance, accounting for 6.9%, 2.7%, and academic performance was explained by the studied variables. Hence, efficacious mechanisms should be designed to combat the intervenable determinants of self-reported academic performance, like substance use and a low medical school entrance examination result. Further studies should also be undertaken to gain a better understanding of other unstudied determinants, like personality, learning style, cognitive ability, and the system used for academic evaluation.

  20. Design, validation, and use of an evaluation instrument for monitoring systemic reform

    Science.gov (United States)

    Scantlebury, Kathryn; Boone, William; Butler Kahle, Jane; Fraser, Barry J.

    2001-08-01

    Over the past decade, state and national policymakers have promoted systemic reform as a way to achieve high-quality science education for all students. However, few instruments are available to measure changes in key dimensions relevant to systemic reform such as teaching practices, student attitudes, or home and peer support. Furthermore, Rasch methods of analysis are needed to permit valid comparison of different cohorts of students during different years of a reform effort. This article describes the design, development, validation, and use of an instrument that measures student attitudes and several environment dimensions (standards-based teaching, home support, and peer support) using a three-step process that incorporated expert opinion, factor analysis, and item response theory. The instrument was validated with over 8,000 science and mathematics students, taught by more than 1,000 teachers in over 200 schools as part of a comprehensive assessment of the effectiveness of Ohio's systemic reform initiative. When the new four-factor, 20-item questionnaire was used to explore the relative influence of the class, home, and peer environment on student achievement and attitudes, findings were remarkably consistent across 3 years and different units and methods of analysis. All three environments accounted for unique variance in student attitudes, but only the environment of the class accounted for unique variance in student achievement. However, the class environment (standards-based teaching practices) was the strongest independent predictor of both achievement and attitude, and appreciable amounts of the total variance in attitudes were common to the three environments.

  1. Self-reported Quality of ADL Task Performance in Adults with Schizophrenia

    DEFF Research Database (Denmark)

    Nielsen, Kristina Tomra; Petersen, Rikke S.; Wæhrens, Eva Ejlersen

    quality of both personal ADL (PADL) and instrumental ADL (IADL). Aside from decreased independence, the participants also reported problems related to increased effort, increased use of time, and some safety issues. Although most of the participants reported to be competent in relation to PADL tasks......, how they perceive the quality of their performance in terms of effort/fatigue, use of time, safety risks, and need for assistance. The aim was to investigate the self-reported quality of ADL task performance in adults with schizophrenia. Subjects Participants were recruited from October 2013...... evaluation tool developed to describe and measure the quality of ADL task performance in terms of effort/fatigue, use of time, safety risks, and need for assistance based on self-report. Occupational therapists employed at the hospitals and trained in conducting the ADL–I were collecting data. The interviews...

  2. Suitability of open-field autorefractors as pupillometers and instrument design effects

    Directory of Open Access Journals (Sweden)

    Carles Otero

    2017-04-01

    Full Text Available AIM: To determine the agreement and repeatability of the pupil measurement obtained with VIP-200 (Neuroptics, PowerRef II (Plusoptix, WAM-5500 (Grand Seiko and study the effects of instrument design on pupillometry. METHODS: Forty patients were measured twice in low, mid and high mesopic. Repeatability was analyzed with the within-subject standard deviation (Sw and paired t-tests. Agreement was studied with Bland-Altman plots and repeated measures ANOVA. Instrument design analysis consisted on measuring pupil size with PowerRef II simulating monocular and binocular conditions as well as with proximity cues and without proximity cues. RESULTS: The mean difference (±standard deviation between test-retest for low, mid and high mesopic conditions were, respectively: -0.09 (±0.16, -0.05 (±0.18 and -0.08 (±0.23 mm for Neuroptics, -0.05 (±0.17, -0.12 (±0.23 and -0.17 (±0.34 mm for WAM-5500, -0.04 (±0.27, -0.13 (±0.37 and -0.11 (±0.28 mm for PowerRef II. Regarding agreement with Neuroptics, the mean difference for low, mid and high mesopic conditions were, respectively: -0.48 (±0.35, -0.83 (±0.52 and -0.38 (±0.56 mm for WAM-5500, -0.28 (±0.56, -0.70 (±0.55 and -0.61 (±0.54 mm for PowerRef II. The mean difference of binocular minus monocular pupil measurements was: -0.83 (±0.87 mm; and with proximity cues minus without proximity cues was: -0.30 (±0.77 mm. CONCLUSION: All the instruments show similar repeat-ability. In all illumination conditions, agreement of Neuroptics with WAM-5500 and PowerRef II is not good enough, which can be partially induced due to their open field design.

  3. Suitability of open-field autorefractors as pupillometers and instrument design effects.

    Science.gov (United States)

    Otero, Carles; Aldaba, Mikel; Ferrer, Oriol; Gascón, Andrea; Ondategui-Parra, Juan C; Pujol, Jaume

    2017-01-01

    To determine the agreement and repeatability of the pupil measurement obtained with VIP-200 (Neuroptics), PowerRef II (Plusoptix), WAM-5500 (Grand Seiko) and study the effects of instrument design on pupillometry. Forty patients were measured twice in low, mid and high mesopic. Repeatability was analyzed with the within-subject standard deviation (Sw) and paired t -tests. Agreement was studied with Bland-Altman plots and repeated measures ANOVA. Instrument design analysis consisted on measuring pupil size with PowerRef II simulating monocular and binocular conditions as well as with proximity cues and without proximity cues. The mean difference (±standard deviation) between test-retest for low, mid and high mesopic conditions were, respectively: -0.09 (±0.16), -0.05 (±0.18) and -0.08 (±0.23) mm for Neuroptics, -0.05 (±0.17), -0.12 (±0.23) and -0.17 (±0.34) mm for WAM-5500, -0.04 (±0.27), -0.13 (±0.37) and -0.11 (±0.28) mm for PowerRef II. Regarding agreement with Neuroptics, the mean difference for low, mid and high mesopic conditions were, respectively: -0.48 (±0.35), -0.83 (±0.52) and -0.38 (±0.56) mm for WAM-5500, -0.28 (±0.56), -0.70 (±0.55) and -0.61 (±0.54) mm for PowerRef II. The mean difference of binocular minus monocular pupil measurements was: -0.83 (±0.87) mm; and with proximity cues minus without proximity cues was: -0.30 (±0.77) mm. All the instruments show similar repeat-ability. In all illumination conditions, agreement of Neuroptics with WAM-5500 and PowerRef II is not good enough, which can be partially induced due to their open field design.

  4. MDEP Common Position No EPR-01 - Common positions on the EPR instrumentation and controls design

    International Nuclear Information System (INIS)

    2010-01-01

    The purpose of the EPR Working Group (EPRWG) of the Multinational Design Evaluation Program (MDEP) is to identify common positions among the regulators reviewing the EPR Instrumentation and Controls (I and C) Systems in order to: 1. Promote understanding of each country 's regulatory decisions and basis for the decisions, 2. Enhance communication among the members and with external stakeholders, 3. Identify areas where harmonization and convergence of regulations, standards, and guidance can be achieved or improved, and 4. Supports standardization of new reactor designs. Since January 2008, the EPR I and C Technical Expert Subgroup (TESG) members met five times to exchange information regarding their country 's review of the EPR I and C design. The EPR I and C TESG consists of regulators from China, Canada, Finland, France, the United Kingdom, and the United States. The information exchange includes presentation of each country 's review status and technical issues, sharing of guidance documents, and sharing of regulatory decision documents. The TESG focused on the following four core areas of the EPR I and C design: 1. I and C System Independence (particularly for data communications), 2. Level of Defense and Diversity (back-up systems), 3. Qualification/quality of digital platforms, 4. Categorization/classification of systems and functions. As meetings were conducted, some areas were emphasized more depending on the significance of the issues for each country. During the TESG interactions, it became apparent that there were aspects of the EPR design where the countries had common agreement. On November 2, 2009, three of the subgroup countries, France, Finland and the United Kingdom, issued a joint regulatory position on the EPR I and C design as result of the 'Groupe Permanent' meeting in France. This statement of common positions expands upon that joint regulatory position

  5. Design of Simple Instrumentation System for the Quality Analysis of Milk (Casein Analysis

    Directory of Open Access Journals (Sweden)

    V. G. Sangam

    2010-08-01

    Full Text Available This paper describes the design of a simple instrumentation system for the analysis of casein concentration in the milk. Casein is one of the major constituent of milk and its concentration describes the quality of the milk. Normally casein is analyzed by conventional analytical methods or by using Spectrophotometric methods. Here an attempt has been made to develop a simple portable system using optical instrumentation technique. The objective of the developed system is the real time analysis of the casein concentration of the milk at the field. The system involves UV light source, UV filter, cuvette, photo detector, display unit, data Acquisition Card (DAC as peripheral with USB port. Appropriate program has been developed in visual studio 6 and turbo C. Repeated number of real time analysis was carried out for different samples of milk; the results obtained are in excellent agreement with the amount determined by standard conventional methods with an accuracy of ±1.5 %, and the response time is within 100 seconds. This system can be used in the field for the quality analysis of milk as an independent unit and can also be interfaced to PC with USB port. The system has good accuracy, less response time and low cost.

  6. Characterization of transimpedance amplifier as optical to electrical converter on designing optical instrumentation

    International Nuclear Information System (INIS)

    Hanto, D; Ula, R K

    2017-01-01

    Optical to electrical converter is the main components for designing of the optical instrumentations. In addition, this component is also used as signal conditioning. This component usually consists of a photo detector and amplifier. In this paper, characteristics of commercial amplifiers from Thorlabs PDA50B-EC has been observed. The experiment was conducted by diode laser with power of -5 dBm and wavelength 1310 nm; the optical attenuator to vary optical power from 0 to 60 dB, optical to electrical converter from Thorlabs Amplifier PDA50B-EC; multimode optical fiber to guide the laser; and digital voltmeter to measure the output of converter. The results of the characterization indicate that each channel amplification has a non-linear correlation between optical and electrical parameter; optical conversion measurement range of 20-23 dB to full scale; and different measurement coverage area. If this converter will be used as a part component of optical instrumentation so it should be adjusted suitably with the optical power source. Then, because of the correlation equation is not linear so calculation to determine the interpretation also should be considered in addition to the transfer function of the optical sensor. (paper)

  7. Characterization of transimpedance amplifier as optical to electrical converter on designing optical instrumentation

    Science.gov (United States)

    Hanto, D.; Ula, R. K.

    2017-05-01

    Optical to electrical converter is the main components for designing of the optical instrumentations. In addition, this component is also used as signal conditioning. This component usually consists of a photo detector and amplifier. In this paper, characteristics of commercial amplifiers from Thorlabs PDA50B-EC has been observed. The experiment was conducted by diode laser with power of -5 dBm and wavelength 1310 nm; the optical attenuator to vary optical power from 0 to 60 dB, optical to electrical converter from Thorlabs Amplifier PDA50B-EC; multimode optical fiber to guide the laser; and digital voltmeter to measure the output of converter. The results of the characterization indicate that each channel amplification has a non-linear correlation between optical and electrical parameter; optical conversion measurement range of 20-23 dB to full scale; and different measurement coverage area. If this converter will be used as a part component of optical instrumentation so it should be adjusted suitably with the optical power source. Then, because of the correlation equation is not linear so calculation to determine the interpretation also should be considered in addition to the transfer function of the optical sensor.

  8. Predictors of self-reported academic performance among undergraduate medical students of Hawassa University, Ethiopia

    Directory of Open Access Journals (Sweden)

    Gedefaw A

    2015-04-01

    % confidence interval 1.25–3.02 and less likely to be delayed, have to re-sit an examination, or be warned (adjusted odds ratio 0.47, 95% confidence interval 0.29–0.77. Conclusion: Only 32.8% of the variation in self-reported academic performance was explained by the studied variables. Hence, efficacious mechanisms should be designed to combat the intervenable determinants of self-reported academic performance, like substance use and a low medical school entrance examination result. Further studies should also be undertaken to gain a better understanding of other unstudied determinants, like personality, learning style, cognitive ability, and the system used for academic evaluation. Keywords: predictors, academic performance, medical students, Ethiopia

  9. Space Power Program, Instrumentation and Control System Architecture, Preconceptual Design, for Information

    International Nuclear Information System (INIS)

    JM Ross

    2005-01-01

    The purpose of this letter is to forward the Prometheus preconceptual Instrumentation and Control (I and C) system architecture (Enclosure (1)) to NR for information as part of the Prometheus closeout work. The preconceptual 1 and C system architecture was considered a key planning document for development of the I and C system for Project Prometheus. This architecture was intended to set the technical approach for the entire I and C system. It defines interfaces to other spacecraft systems, defines hardware blocks for future development, and provides a basis for accurate cost and schedule estimates. Since the system requirements are not known at this time, it was anticipated that the architecture would evolve as the design of the reactor module was matured

  10. Design of Instrumentation and Control Systems for Nuclear Power Plants. Specific Safety Guide

    International Nuclear Information System (INIS)

    2016-01-01

    This publication is a revision and combination of two Safety Guides, IAEA Safety Standards Series No. NS-G-1.1 and No. NS-G-1.3. The revision takes into account developments in instrumentation and control (I&C) systems since the publication of the earlier Safety Guides. The main changes relate to the continuing development of computer applications and the evolution of the methods necessary for their safe, secure and practical use. In addition, account is taken of developments in human factors engineering and the need for computer security. This Safety Guide references and takes into account other IAEA Safety Standards and Nuclear Security Series publications that provide guidance relating to I&C design

  11. Design and application of a continuous, digital-output, environmental radon measuring instrument

    International Nuclear Information System (INIS)

    Spitz, H.; Wrenn, M.E.

    1977-01-01

    A radon measuring instrument has been developed which can continuously measure environmental concentrations of radon in the atmosphere without employing any air movers or pumps. The unit is entirely passive in design and relies upon the diffusion of radon for sample collection. Since radon is an inert noble gas it will follow the classical theory of motion and diffuse in a direction dependent upon the concentration gradient existing between the atmosphere and the sensitive portion of the detector. A porous foam filter allows radon, but not its daughters, to enter the detector where an electrostatic field is maintained to facilitate collection of the decay products of radon, i.e., initially the positive ions of RaA (Po-218). Alpha particles from RaA and RaC' (Po-214) within the sensitive volume are detected using a ZnS scintillator and photomultiplier tube with the usual complement of electronics

  12. Space Power Program, Instrumentation and Control System Architecture, Pre-conceptual Design, for Information

    Energy Technology Data Exchange (ETDEWEB)

    JM Ross

    2005-10-20

    The purpose of this letter is to forward the Prometheus preconceptual Instrumentation and Control (I&C) system architecture (Enclosure (1)) to NR for information as part of the Prometheus closeout work. The preconceptual 1&C system architecture was considered a key planning document for development of the I&C system for Project Prometheus. This architecture was intended to set the technical approach for the entire I&C system. It defines interfaces to other spacecraft systems, defines hardware blocks for future development, and provides a basis for accurate cost and schedule estimates. Since the system requirements are not known at this time, it was anticipated that the architecture would evolve as the design of the reactor module was matured.

  13. Transmutation of singularities and zeros in graded index optical instruments: a methodology for designing practical devices.

    Science.gov (United States)

    Hooper, I R; Philbin, T G

    2013-12-30

    We describe a design methodology for modifying the refractive index profile of graded-index optical instruments that incorporate singularities or zeros in their refractive index. The process maintains the device performance whilst resulting in graded profiles that are all-dielectric, do not require materials with unrealistic values, and that are impedance matched to the bounding medium. This is achieved by transmuting the singularities (or zeros) using the formalism of transformation optics, but with an additional boundary condition requiring the gradient of the co-ordinate transformation be continuous. This additional boundary condition ensures that the device is impedance matched to the bounding medium when the spatially varying permittivity and permeability profiles are scaled to realizable values. We demonstrate the method in some detail for an Eaton lens, before describing the profiles for an "invisible disc" and "multipole" lenses.

  14. An automated calibration laboratory for flight research instrumentation: Requirements and a proposed design approach

    Science.gov (United States)

    Oneill-Rood, Nora; Glover, Richard D.

    1990-01-01

    NASA's Dryden Flight Research Facility (Ames-Dryden), operates a diverse fleet of research aircraft which are heavily instrumented to provide both real time data for in-flight monitoring and recorded data for postflight analysis. Ames-Dryden's existing automated calibration (AUTOCAL) laboratory is a computerized facility which tests aircraft sensors to certify accuracy for anticipated harsh flight environments. Recently, a major AUTOCAL lab upgrade was initiated; the goal of this modernization is to enhance productivity and improve configuration management for both software and test data. The new system will have multiple testing stations employing distributed processing linked by a local area network to a centralized database. The baseline requirements for the new AUTOCAL lab and the design approach being taken for its mechanization are described.

  15. Attention deficit hyperactivity disorder symptom self-report among ...

    African Journals Online (AJOL)

    Attention deficit hyperactivity disorder symptom self-report among medical students in Eldoret, Kenya. ... checklist to approximate a Diagnostic and Statistical Manual of Mental Disorders, 4th edition, text revision (DSM-IV-TR) ADHD diagnosis ...

  16. Attention deficit hyperactivity disorder symptom self-report among ...

    African Journals Online (AJOL)

    Objective: To determine the prevalence of self-reported attention deficit hyperactivity disorder (ADHD) symptoms among medical students in Eldoret ... divided into two parts. ... representatives prior to the start of whole-class activities and.

  17. The Effect of Femoral Cutting Guide Design Improvements for Patient-Specific Instruments

    Directory of Open Access Journals (Sweden)

    Oh-Ryong Kwon

    2015-01-01

    Full Text Available Although the application of patient-specific instruments (PSI for total knee arthroplasty (TKA increases the cost of the surgical procedure, PSI may reduce operative time and improve implant alignment, which could reduce the number of revision surgeries. We report our experience with TKA using PSI techniques in 120 patients from March to December 2014. PSI for TKA were created from data provided by computed tomography (CT scans or magnetic resonance imaging (MRI; which imaging technology is more reliable for the PSI technique remains unclear. In the first 20 patients, the accuracy of bone resection and PSI stability were compared between CT and MRI scans with presurgical results as a reference; MRI produced better results. In the second and third groups, each with 50 patients, the results of bone resection and stability were compared in MRI scans with respect to the quality of scanning due to motion artifacts and experienced know-how in PSI design, respectively. The optimized femoral cutting guide design for PSI showed the closest outcomes in bone resection and PSI stability with presurgical data. It is expected that this design could be a reasonable guideline in PSI.

  18. Lessons Learned from GOSAT; Instrument Design, Calibration, Operation, Data Processing, and International Collaboration

    Science.gov (United States)

    Kuze, A.; Suto, H.; Shiomi, K.; Nakajima, M.

    2012-12-01

    Advantage of satellite observation is its ability to monitor long term and global distribution with a single instrument. Ozone observation from space has been successful for long term monitoring purposes. Monitoring gradual increase and distribution of greenhouse gases in the troposphere with sub-percent accuracy has become a challenging subject. Interference of cloud and aerosol in radiative transfer has to be corrected for troposphere measurement. Accurate O2-A band measurement can retrieve surface pressure and aerosol distribution property. We have selected a Fourier Transform spectrometer (FTS) to achieve high throughput and wide spectral coverage with uniform spectral resolution. On the other hand, it is difficult to modulate short wave such as 0.76μm and avoid micro vibration interference. Prelaunch, we took special care to select optical components of excellent surface quality and isolate vibration. Design parameters such as IFOV, spectral resolution, observation interval within limited satellite resources must be carefully optimized. Greenhouse gases Observing SATellite (GOSAT) has been providing global high spectral resolution data for almost 4 years. Instrument performance, radiometric calibration, radiative transfer calculation and laboratory spectroscopy are all important. The first step was to reduce bias of column-averaged dry air mole fractions (the Level 2 product) of CO2 and CH4 (XCO2 and XCH4) and validate using well calibrated data such as TCCON. After 2 years of operation, latitudinal distribution of zonal mean and seasonal variation at these sites can be measured with better than 2ppm accuracy. However, validations are limited to ideal conditions. Next step is to evaluate consistency of measured values from long periods since launch, different surface types, and various input radiance with different instrument gain. For long term radiometric calibration, we have uses vicarious, onboard solar diffuser, and lunar calibration data. Over the ocean

  19. Safety Research Experiment Facility Project. Conceptual design report. Volume VIII. Instrumentation and control

    International Nuclear Information System (INIS)

    1975-01-01

    Included are sections dealing with the following: nuclear instrumentation system, reactor control system, plant protection system, plant annunciator system, data acquisition system, and reactor cooling system instrumentation and control

  20. Status of Foreground and Instrument Challenges for 21cm EoR experiments - Design Strategies for SKA and HERA

    Science.gov (United States)

    Thyagarajan, Nithyanandan

    2018-05-01

    Direct detection of the Epoch of Reionization (EoR) via redshifted 21 cm line of H i will reveal the nature of the first stars and galaxies as well as revolutionize our understanding of a poorly explored evolutionary phase of the Universe. Projects such as the MWA, LOFAR, and PAPER commenced in the last decade with the promise of high significance statistical detection of the EoR, but have so far only weakly constrained models owing to unforeseen challenges from bright foreground sources and instrument systematics. It is essential for next generation instruments like the HERA and SKA to have these challenges addressed. I present an analysis of these challenges - wide-field measurements, antenna beam chromaticity, reflections in the instrument, and antenna position errors - along with performance specifications and design solutions that will be critical to designing successful next-generation instruments in enabling the first detection and also in placing meaningful constraints on reionization models.

  1. Headache and musculoskeletal complaints among subjects with self reported whiplash injury. The HUNT-2 study

    Directory of Open Access Journals (Sweden)

    Nygaard Oystein

    2011-06-01

    Full Text Available Abstract Background To evaluate the life-time prevalence of self reported whiplash injury and the relationship to chronic musculoskeletal complaints (MSCs and headache in a large unselected adult population. Methods Between 1995 and 1997, all inhabitants 20 years and older in Nord-Trondelag county in Norway were invited to a comprehensive health survey. Out of 92,936 eligible for participation, a total of 59,104 individuals (63.6% answered the question about whiplash injury (whiplash. Among these, 46,895 (79.3% responded to the questions of musculoskeletal complaints and headache. Results The total life-time prevalence of self reported whiplash injury was 2.9%, for women 2.7% and for men 3.0%. There was a significant association between self reported whiplash injury and headache (OR = 2.1; 95% CI 1.8-2.4, and chronic MSCs (OR = 3.3; 95% CI 2.8-3.8, evident for all ten anatomical sites investigated. The association was most pronounced for those with a combination of headache and chronic MSC for both men (OR = 4.8; 95% CI 3.6-6.2 and women (OR = 5.2; 95% CI 3.7-7.1. Conclusions Subjects with self reported whiplash injury had significantly more headache and musculoskeletal complaints than those without, and may in part be due to selective reporting. The causal mechanism remains unclear and cannot be addressed in the present study design.

  2. Correlates of Self-Report of Rape Among Male School Adolescents in Ile-Ife, Nigeria.

    Science.gov (United States)

    Ogunfowokan, Adesola A; Olagunju, Oluwayemisi E; Olajubu, Aanuoluwapo O; Faremi, Funmilola A; Oloyede, Ajoke S; Sharps, Phyllis W

    2016-02-01

    This study examined male adolescents' self-report of rape of adolescent girls and the socio-demographic variables that correlated with self-report of rape. Descriptive-correlational design was used and the study was conducted in five public senior secondary schools in Ile-Ife, Nigeria. Three hundred and thirty-eight male adolescents participated in the study. A structured questionnaire was used to collect data. Findings from the study revealed the mean age of the adolescent males to be 16 years, with the majority (73%) of them in the middle adolescent stage. Six percent of the adolescent males reported they had raped an adolescent girl in the past. Among the boys who reported rape, 55% reported they had raped their sexual partners, and 55% reported they had perpetrated gang rape. Smoking (p = .0001), alcohol consumption (p = .001), and birth order (p = .006) predicted self-report of rape. The coefficient of birth order showed that odds of self-report of rape by first-born male increases by 6 times compared with other children. Study findings also provided evidence that adolescent males are moving from lone rape to gang rape in intimate partner relationships. Male adolescents are important group to target in rape prevention programs. © The Author(s) 2014.

  3. Self-report and longitudinal predictors of violence in Iraq and Afghanistan war era veterans.

    Science.gov (United States)

    Elbogen, Eric B; Johnson, Sally C; Newton, Virginia M; Fuller, Sara; Wagner, H Ryan; Beckham, Jean C

    2013-10-01

    This study, using a longitudinal design, attempted to identify whether self-reported problems with violence were empirically associated with future violent behavior among Iraq and Afghanistan war veterans and whether and how collateral informant interviews enhanced the risk assessment process. Data were gathered from N = 300 participants (n = 150 dyads of Iraq and Afghanistan war veterans and family/friends). The veterans completed baseline and follow-up interviews 3 years later on average, and family/friends provided collateral data on dependent measures at follow-up. Analyses showed that aggression toward others at follow-up was associated with younger age, posttraumatic stress disorder, combat exposure, and a history of having witnessed parental violence growing up. Self-reported problems controlling violence at baseline had robust statistical power in predicting aggression toward others at follow-up. Collateral report enhanced detection of dependent variables: 20% of cases positive for violence toward others would have been missed relying only on self-report. The results identify a subset of Iraq and Afghanistan war veterans at higher risk for problematic postdeployment adjustment and indicate that the veterans' self-report of violence was useful in predicting future aggression. Underreporting of violence was not evidenced by most veterans but could be improved upon by obtaining collateral information.

  4. Relationships between self-reported physical and mental health and intelligence performance across adulthood.

    Science.gov (United States)

    Perlmutter, M; Nyquist, L

    1990-07-01

    One hundred and twenty-seven adults between 20 and 90 years of age were tested on the Wechsler Adult Intelligence Scale for their digit span memory (forward and backward), fluid intelligence (block design and digit symbol), and crystallized intelligence (vocabulary and information), as well as assessed for self-reported health (Cornell Medical Index, Zung Depression Scale, health habits, and self-ratings of physical and mental health). As expected, across the entire age range there was no correlation between age and digit span memory (r = .03), a strong negative correlation between age and fluid intelligence (r = -.78), and a modest positive correlation between age and crystallized intelligence (r = .27). In addition, older adults reported more physical (r = .36) and mental (r = .32) health problems than did younger adults. Of special interest was the finding that both self-reported physical and mental health accounted for significant variance in intelligence performance, particularly in older adults. Moreover, self-reported health accounted for a considerable portion of observed variance, even when age differences in self-reported health were statistically controlled.

  5. Design and manufacturing of non-instrumented capsule for advanced PWR fuel pellet irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Song, K. W. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-04-01

    This project is preparing to irradiation test of the developed large grain UO{sub 2} fuel pellet in HANARO for pursuit fuel safety and high burn-up in 'Advanced LWR Fuel Technology Development Project' as a part Nuclear Mid and Long-term R and D Program. On the basis test rod is performed the nuclei property and preliminary fuel performance analysis, test rod and non-instrumented capsule are designed and manufactured for irradiation test in HANARO. This non-instrumented irradiation capsule of Advanced PWR Fuel pellet was referred the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO(DUPIC Rig-001) and 18-element HANARO fuel, was designed to ensure the integrity and the endurance of non-instrumented capsule during the long term(2.5 years) irradiation. To irradiate the UO{sub 2} pellets up to the burn-up 70 MWD/kgU, need the time about 60 months and ensure the integrity of non-instrumented capsule for 30 months until replace the new capsule. This non-instrumented irradiation capsule will be based to develope the non-instrumented capsule for the more long term irradiation in HANARO. 22 refs., 13 figs., 5 tabs. (Author)

  6. Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals.

    Science.gov (United States)

    Kim, H C; Kim, H J; Lee, C J; Kim, B M; Park, J K; Versluis, A

    2009-07-01

    To evaluate how different cross-sectional designs affect stress distribution in nickel-titanium (NiTi) instruments during bending, torsion and simulated shaping of a curved canal. Four NiTi rotary instruments with different cross-sectional geometries were selected: ProFile and HeroShaper systems with a common triangle-based cross section, Mtwo with an S-shaped rectangle-based design and NRT with a modified rectangle-based design. The geometries of the selected files were scanned in a micro-CT and three-dimensional finite-element models were created for each system. Stiffness characteristics for each file system were determined in a series of bending and torsional conditions. Canal shaping was simulated by inserting models of the rotating file into a 45 degrees curved canal model. Stress distribution in the instruments was recorded during simulated shaping. After the instruments were retracted from the canal, residual stresses and permanent bending of their tips due to plastic deformation were determined. The greatest bending and torsional stiffness occurred in the NRT file. During simulated shaping, the instruments with triangle-based cross-sectional geometry had more even stress distributions along their length and had lower stress concentrations than the instruments with rectangle-based cross sections. Higher residual stresses and plastic deformations were found in the Mtwo and NRT with rectangle-based cross-sectional geometries. Nickel-titanium instruments with rectangle-based cross-sectional designs created higher stress differentials during simulated canal shaping and may encounter higher residual stress and plastic deformation than instruments with triangle-based cross sections.

  7. Advances in nuclear medicine instrumentation: considerations in the design and selection of an imaging system

    International Nuclear Information System (INIS)

    Links, J.M.

    1998-01-01

    Nuclear medicine remains a vibrant and dynamic medical specialty because it so adeptly marries advances in basic science research, technology, and medical practice in attempting to solve patients' problems. As a physicist, it is my responsibility to identify or design new instrumentation and techniques, and to implement, validate, and help apply these new approaches in the practice of nuclear medicine. At Johns Hopkins, we are currently in the process of purchasing both a single-photon/coincidence tomographic imaging system and a dedicated positron emission tomography (PET) scanner. Given the exciting advances that have been made, but the conflicting opinions of manufacturers and colleagues alike regarding ''best'' choices, it seemed useful to review what is new now, and what is on the horizon, to help identify all of the important considerations in the design and selection of an imaging system. It is important to note that many of the ''advances'' described here are in an early stage of development, and may never make it to routine clinical practice. Further, not all of the advances are of equal importance, or have the same degree of general clinical applicability. Please also note that the references contained herein are for illustrative purposes and are not all-inclusive; no implication that those chosen are ''better'' than others not mentioned is intended. (orig.)

  8. Experimental design technique applied to the validation of an instrumental Neutron Activation Analysis procedure

    International Nuclear Information System (INIS)

    Santos, Uanda Paula de M. dos; Moreira, Edson Gonçalves

    2017-01-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) method were carried out for the determination of the elements bromine, chlorine, magnesium, manganese, potassium, sodium and vanadium in biological matrix materials using short irradiations at a pneumatic system. 2 k experimental designs were applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. The chosen experimental designs were the 2 3 and the 2 4 , depending on the radionuclide half life. Different certified reference materials and multi-element comparators were analyzed considering the following variables: sample decay time, irradiation time, counting time and sample distance to detector. Comparator concentration, sample mass and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations, it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN /CNEN-SP). Optimized conditions were estimated based on the results of z-score tests, main effect, interaction effects and better irradiation conditions. (author)

  9. Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak.

    Science.gov (United States)

    Pan, X M; Yang, Z J; Ma, X D; Zhu, Y L; Luhmann, N C; Domier, C W; Ruan, B W; Zhuang, G

    2016-11-01

    A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advanced optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.

  10. Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Pan, X. M.; Yang, Z. J., E-mail: yangzj@hust.edu.cn; Ma, X. D.; Ruan, B. W.; Zhuang, G. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Zhu, Y. L. [School of Physics, University of Science and Technology of China, Anhui 230026 (China); Luhmann, N. C.; Domier, C. W. [Davis Millimeter Wave Research Center, University of California, Davis, California 95616 (United States)

    2016-11-15

    A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advanced optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.

  11. Experimental design technique applied to the validation of an instrumental Neutron Activation Analysis procedure

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Uanda Paula de M. dos; Moreira, Edson Gonçalves, E-mail: uandapaula@gmail.com, E-mail: emoreira@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) method were carried out for the determination of the elements bromine, chlorine, magnesium, manganese, potassium, sodium and vanadium in biological matrix materials using short irradiations at a pneumatic system. 2{sup k} experimental designs were applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. The chosen experimental designs were the 2{sup 3} and the 2{sup 4}, depending on the radionuclide half life. Different certified reference materials and multi-element comparators were analyzed considering the following variables: sample decay time, irradiation time, counting time and sample distance to detector. Comparator concentration, sample mass and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations, it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN /CNEN-SP). Optimized conditions were estimated based on the results of z-score tests, main effect, interaction effects and better irradiation conditions. (author)

  12. A modification design and adjusting test for instruments and control system of critical assembly

    International Nuclear Information System (INIS)

    Wu Manrong; Li Guangjian

    1996-12-01

    A more reliable and safe control system and it's instruments for HFETRCA (high flux engineering test reactor critical assembly) have been built. In the system high performance CMOS unit was used, which has high integration, strong anti-interference and high trigger threshold. In the design of control rod driving circuit, the speed negative feedback principle was applied that results in more stable rotating rate of motors of transmission mechanism and more flexibility of adjusting rod speed. In order to improve reactor safety in accident, additional control circuit is equipped, by which not only control rods with electromagnet will rapidly drop but also other control rods will insert at the speed of 2∼6 times faster than the normal inserting speed. The key technique in the adjustment and new method of anti-interference are also introduced. After more than 40 times physical experiments with (4 x 4 - 4) fuel element in HFETRC, it is proved that the design and adjustment of the system is successful and they can be used as a reference to others. (3 figs., 2 tabs.)

  13. Development and validation of Dutch version of Lasater Clinical Judgment Rubric in hospital practice: An instrument design study.

    Science.gov (United States)

    Vreugdenhil, Jettie; Spek, Bea

    2018-03-01

    Clinical reasoning in patient care is a skill that cannot be observed directly. So far, no reliable, valid instrument exists for the assessment of nursing students' clinical reasoning skills in hospital practice. Lasater's clinical judgment rubric (LCJR), based on Tanner's model "Thinking like a nurse" has been tested, mainly in academic simulation settings. The aim is to develop a Dutch version of the LCJR (D-LCJR) and to test its psychometric properties when used in a hospital traineeship context. A mixed-model approach was used to develop and to validate the instrument. Ten dedicated educational units in a university hospital. A well-mixed group of 52 nursing students, nurse coaches and nurse educators. A Delphi panel developed the D-LCJR. Students' clinical reasoning skills were assessed "live" by nurse coaches, nurse educators and students who rated themselves. The psychometric properties tested during the assessment process are reliability, reproducibility, content validity and construct validity by testing two hypothesis: 1) a positive correlation between assessed and self-reported sum scores (convergent validity) and 2) a linear relation between experience and sum score (clinical validity). The obtained D-LCJR was found to be internally consistent, Cronbach's alpha 0.93. The rubric is also reproducible with intraclass correlations between 0.69 and 0.78. Experts judged it to be content valid. The two hypothesis were both tested significant, supporting evidence for construct validity. The translated and modified LCJR, is a promising tool for the evaluation of nursing students' development in clinical reasoning in hospital traineeships, by students, nurse coaches and nurse educators. More evidence on construct validity is necessary, in particular for students at the end of their hospital traineeship. Based on our research, the D-LCJR applied in hospital traineeships is a usable and reliable tool. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. DESIGN AND TEST OF AN INSTRUMENT FOR MEASURING MICROTHERMAL SEEING ON THE MAGDALENA RIDGE

    International Nuclear Information System (INIS)

    Jorgensen, A. M.; Klinglesmith, D. A.; Speights, J.; Clements, A.; Patel, J.

    2009-01-01

    We have constructed and operated an automated instrument for measuring ground-level microthermal seeing at the Magdalena Ridge Observatory (MRO). The MRO is located at an altitude of 10500' in the Cibola National Forest in New Mexico, USA. It is the planned site for the MRO Optical Interferometer (MROI) planned for up to 10 collecting elements, each with a diameter of 1.4 m, and baselines eventually up to approximately 400 m. As part of the preparation for construction we deployed a system to characterize the ground-level seeing across the observatory site. The instrument is built largely of off-the-shelf components, with only the sensor head and power supply requiring electronic board assembly. Even in those cases the board architecture is very simple. The first proof-of-concept system was deployed for several weeks in the autumn of 2004, and has since undergone several iterations. The latest configuration operates entirely off batteries, incorporates wireless data acquisition, and is thus able to operate in an area with no shelter, power, or communications. In this paper we present the design of the instrument, and show initial data. The microthermal tower has four sensor pairs at heights from 0.8 to 4.41 m, significantly lower than other microthermal experiments, because of the need to characterize the seeing near the ground. We find significant variation in the contribution of this range of heights to the seeing, contributing up to 0.''3 of the seeing at some times and only 0.''02 at other times. The individual sensor power spectra have a slope in the range of 1.4--1.5, which is lower than the 1.67 slope predicted by Kolmogorov turbulence theory. We measure the well known effect of improved seeing immediately around sunset. While we find significant variation in the microthermal seeing, we did not find a pattern of corresponding variations in weather conditions, suggesting that a complicated set of factors control microthermal turbulence.

  15. Design and Test of an Instrument for Measuring Microthermal Seeing on the Magdalena Ridge

    Science.gov (United States)

    Jorgensen, A. M.; Klinglesmith, D. A., III; Speights, J.; Clements, A.; Patel, J.

    2009-05-01

    We have constructed and operated an automated instrument for measuring ground-level microthermal seeing at the Magdalena Ridge Observatory (MRO). The MRO is located at an altitude of 10500' in the Cibola National Forest in New Mexico, USA. It is the planned site for the MRO Optical Interferometer (MROI) planned for up to 10 collecting elements, each with a diameter of 1.4 m, and baselines eventually up to approximately 400 m. As part of the preparation for construction we deployed a system to characterize the ground-level seeing across the observatory site. The instrument is built largely of off-the-shelf components, with only the sensor head and power supply requiring electronic board assembly. Even in those cases the board architecture is very simple. The first proof-of-concept system was deployed for several weeks in the autumn of 2004, and has since undergone several iterations. The latest configuration operates entirely off batteries, incorporates wireless data acquisition, and is thus able to operate in an area with no shelter, power, or communications. In this paper we present the design of the instrument, and show initial data. The microthermal tower has four sensor pairs at heights from 0.8 to 4.41 m, significantly lower than other microthermal experiments, because of the need to characterize the seeing near the ground. We find significant variation in the contribution of this range of heights to the seeing, contributing up to 0farcs3 of the seeing at some times and only 0farcs02 at other times. The individual sensor power spectra have a slope in the range of 1.4--1.5, which is lower than the 1.67 slope predicted by Kolmogorov turbulence theory. We measure the well known effect of improved seeing immediately around sunset. While we find significant variation in the microthermal seeing, we did not find a pattern of corresponding variations in weather conditions, suggesting that a complicated set of factors control microthermal turbulence.

  16. Rapid and Accurate Behavioral Health Diagnostic Screening: Initial Validation Study of a Web-Based, Self-Report Tool (the SAGE-SR).

    Science.gov (United States)

    Brodey, Benjamin; Purcell, Susan E; Rhea, Karen; Maier, Philip; First, Michael; Zweede, Lisa; Sinisterra, Manuela; Nunn, M Brad; Austin, Marie-Paule; Brodey, Inger S

    2018-03-23

    diagnoses. These 664 items were iteratively submitted to 3 rounds of cognitive interviewing with 50 community mental health center participants; the expert panel reviewed session summaries and agreed on a final set of 661 clear and concise self-report items representing the desired criteria in the DSM-5. The SAGE-SR constructed from this item pool took an average of 14 min to complete in a nonclinical sample versus 24 min in a clinical sample. Responses to individual items can be combined to generate DSM criteria endorsements and differential diagnoses, as well as provide indices of individual symptom severity. Preliminary measures of test-retest reliability in a small, nonclinical sample were promising, with good to excellent reliability for screener items in 11 of 13 diagnostic screening modules (intraclass correlation coefficient [ICC] or kappa coefficients ranging from .60 to .90), with mania achieving fair test-retest reliability (ICC=.50) and other substance use endorsed too infrequently for analysis. The SAGE-SR is a computerized adaptive self-report instrument designed to provide rigorous differential diagnostic information to clinicians. ©Benjamin Brodey, Susan E Purcell, Karen Rhea, Philip Maier, Michael First, Lisa Zweede, Manuela Sinisterra, M Brad Nunn, Marie-Paule Austin, Inger S Brodey. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 23.03.2018.

  17. Emotional skills and competence questionnaire (ESCQ as a self-report measure of emotional intelligence

    Directory of Open Access Journals (Sweden)

    Vladimir Takšić

    2009-11-01

    Full Text Available Studies of emotional intelligence (EI initially appeared in academic journals in the early 1990s. The majority of studies on emotional intelligence have relied on self-ratings. In spite of the critics of self-report scales, there are a large number of self-report measures of EI present in recent literature. The main aim of this paper is to present the constructing procedure, together with the basic psychometric properties of Emotional Skills and Competence Questionnaire (ESCQ as a self-report measure of EI. Originally, this measure was developed in Croatian settings, using the theoretical framework from the Mayer-Salovey emotional intelligence model. The ESCQ instrument has been translated into several languages. The results have showed that ESCQ has three subscales with decent reliability. They share some amount of common variance with similar well-established constructs such as alexithymia, social skills, and personality traits, but they are not correlated with cognitive abilities. However, due to its sufficient reliability, a great deal of unique variance remains. This unique variance of the ESCQ scales has an incremental contribution in explaining life satisfaction and empathy (as the crucial criteria for EI, and has significant relations with relevant real-life criteria such as quality of leadership, health risk behaviors, and school achievement.

  18. Concordance Between Self-Reported Childhood Maltreatment Versus Case Record Reviews for Child Welfare-Affiliated Adolescents.

    Science.gov (United States)

    Negriff, Sonya; Schneiderman, Janet U; Trickett, Penelope K

    2017-02-01

    The present study used data from an ongoing longitudinal study of the effects of maltreatment on adolescent development to (1) describe rates of maltreatment experiences obtained from retrospective self-report versus case record review for adolescents with child welfare-documented maltreatment histories, (2) examine self-reported versus child welfare-identified maltreatment in relation to mental health and risk behavior outcomes by maltreatment type, and (3) examine the association between the number of different types of maltreatment and mental health and risk behavior outcomes. Maltreatment was coded from case records using the Maltreatment Case Record Abstraction Instrument (MCRAI) and participants were asked at mean age = 18.49 about childhood maltreatment experiences using the Comprehensive Trauma Interview (CTI). Results showed that an average of 48% of maltreatment found by the MCRAI for each type of maltreatment were unique cases not captured by the CTI, whereas an average of 40% self-reported maltreatment (CTI) was not indicated by the MCRAI. Analyses with outcomes showed generally, self-reported maltreatment, regardless of concordance with MCRAI, was related to the poorest outcomes. The difference in associations with the outcomes indicates both self-report and case record review data may have utility depending on the outcomes being assessed.

  19. Validity of self-reported criminal justice system involvement in substance abusing women at five-year follow-up

    Directory of Open Access Journals (Sweden)

    Hesse Morten

    2008-01-01

    Full Text Available Abstract Background Few studies have compared self-reported criminal behaviour with high-quality databases of criminal offences and judicial sanctions. Self-reported problems from drug abusers are generally believed to be valid. We assessed the validity of self-reported theft, drug offences and prison sentences from a five-year follow-up of female substance abusers who were originally treated in a compulsory care unit in Lund, run by the Swedish Board of Institutional Care. Methods Data from a total of 106 of a consecutive sample of 132 women inter-viewed in a five-year follow-up. All were thoroughly assessed for somatic complaints, psychiatric and psychological problems, background factors with standardized instruments. Data over the five years were linked to official records of judicial sanctions, retrieved from The National Council for Crime Prevention, Stockholm, Sweden. Register data have a full cover for the whole cohort. The current data base contain full data back to 1975 up to 2004. Results Agreement was assessed for each year, as well as for the total period. Statistical control was performed for other types of crimes and prison. Although statistically significant, agreement was modest, and in contrast to previous studies, patients under-reported violence charges. Conclusion The findings suggest that self-reports of criminal behaviour from women can be used with some caution, and that the validity of self-report may vary between types of criminal justice system involvement.

  20. Kryptonate-based instrumentation development for automobile exhaust pollutants. Phase III report: design and construction of four (4) experimental models

    International Nuclear Information System (INIS)

    Goodman, P.; Donaghue, T.

    This phase of the program encompasses the design, construction and evaluation of four (4) prototype instruments for the detection of automobile exhaust pollutant. These instruments employ the radio release mechanism utilized by Panametrics in detection of various trace gases. The prototype instruments are of two (2) designs. One design is operable from a power source supplied by an automobile battery. The second design is operable from 110 volts AC power. Successful evaluation in the laboratory as well as with various automobiles were performed with both type instruments. Scale-up of the quantity of sensor material prepared introduced unexpected problems with respect to detection lifetime which were not satisfactorily resolved within the time and funds available to the program. Nevertheless, a Kryptonate-based instrument using a single detection method for the measurement of hydrocarbons, CO and NO/sub x/ as pollutants by automobile exhausts was shown to be operable with actual automobile exhausts, to provide more than adequate sensitivity for inspection purposes, and to provide response and recovery times for full scale reading in the range 10-15 secs. (auth)

  1. Leadership: validation of a self-report scale: comment on Dussault, Frenette, and Fernet (2013).

    Science.gov (United States)

    Chakrabarty, Subhra

    2014-10-01

    In a recent study, Dussault, Frenette, and Fernet (2013) developed a 21-item self-report instrument to measure leadership based on Bass's (1985) transformational/transactional leadership paradigm. The final specification included a third-order dimension (leadership), two second-order dimensions (transactional leadership and transformational leadership), and a first-order dimension (laissez-faire leadership). This note focuses on the need for assessing convergent and discriminant validity of the scale, and on ruling out the potential for common method bias.

  2. Self-reported and Observed Quality of ADL Task Performance in Adults with Depression

    DEFF Research Database (Denmark)

    Nielsen, Kristina Tomra; Wæhrens, Eva

    diagnosed with depression (range 19-79, median 45,5) Procedure In order to evaluate the participants’ self-reported and observed quality of ADL task performance the ADL-Interview (ADL-I) and the Assessment of Motor and Process Skills (AMPS) were chosen. Both instruments are developed to evaluate and measure...... the quality of ADL task performance. The ADL-I was conducted first and thereby formed the basis for identifying relevant tasks for the AMPS evaluation. Both evaluations were conducted on the same day by trained and calibrated occupational therapists. Results The results indicated that the participants both...

  3. Validation of self-reported diabetes in a representative sample of São Paulo city

    Directory of Open Access Journals (Sweden)

    Mariane de Mello Fontanelli

    Full Text Available ABSTRACT OBJECTIVE To validate the self-reported diabetes mellitus in adults and older adults living in the city of São Paulo, Brazil. METHODS We have used data of 569 subjects (284 adults and 285 older adults, participants of the population-based cross-sectional study Inquérito de Saúde do Município de São Paulo (Health Survey of São Paulo. Fasting glucose ≥ 7.0 mmol/L (126 mg/dL and/or use of drugs (oral hypoglycemic and/or insulin defined the diagnosis of diabetes mellitus. We have validated the self-reported diabetes mellitus by calculating the sensitivity, specificity, positive predictive values, and negative predictive values. We have used Poisson regression with robust variance to verify the factors associated with the sensitivity of the self-reported datum. For all analyses, we have considered the sample design of the study. RESULTS The sensitivity of self-reported diabetes mellitus was 63.8% (95%CI 49.2–76.3, specificity was 99.7% (95%CI 99.1–99.9, positive predictive value was 95.5% (95%CI 84.4–98.8, and negative predictive value was 96.9% (95%CI 94.9–98.2. The correct reporting of diabetes mellitus was more prevalent among older adults (PR = 2.0; 95%CI 1.2–3.5 than among adults. CONCLUSIONS The use of the datum of self-reported diabetes mellitus is valid, especially among older adults living in the city of São Paulo. The results highlight the need to track diabetes mellitus in asymptomatic subjects who have one or more risk factors for it, mainly in the adult population of this city.

  4. Sleep Characteristics of Self-Reported Long Sleepers

    Science.gov (United States)

    Patel, Sanjay R.; Blackwell, Terri; Ancoli-Israel, Sonia; Stone, Katie L.

    2012-01-01

    Background: Self-reported long habitual sleep durations (≥ 9 h per night) consistently predict increased mortality. We compared objective sleep parameters of self-reported long versus normal duration sleepers to determine whether long sleepers truly sleep more or have an underlying sleep abnormality. Methods: Older men participating in the Osteoporotic Fractures in Men Study (MrOS) were recruited for a comprehensive sleep assessment, which included wrist actigraphy, overnight polysomnography (PSG), and a question about usual nocturnal sleep duration. Results: Of the 3134 participants (mean age 76.4 ± 5.6; 89.9% Caucasian), 1888 (60.2%) reported sleeping 7-8 h (normal sleepers) and 174 (5.6%) reported ≥ 9 h (long sleepers). On actigraphy, long sleepers spent on average 63.0 min more per night in bed (P sleep stage distribution did not differ. After adjusting for differences in demographics, comorbidities, and medication usage, self-reported long sleepers continued to spend more time in bed and sleep more, based on both actigraphy and PSG. Each additional 30 min in bed or asleep as measured by actigraphy increased the odds of being a self-reported long-sleeper 1.74-fold and 1.33-fold, respectively (P sleep disorders. Citation: Patel SR; Blackwell T; Ancoli-Israel S; Stone KL. Sleep characteristics of self-reported long sleepers. SLEEP 2012;35(5):641-648. PMID:22547890

  5. Occlusal factors are not related to self-reported bruxism.

    Science.gov (United States)

    Manfredini, Daniele; Visscher, Corine M; Guarda-Nardini, Luca; Lobbezoo, Frank

    2012-01-01

    To estimate the contribution of various occlusal features of the natural dentition that may identify self-reported bruxers compared to nonbruxers. Two age- and sex-matched groups of self-reported bruxers (n = 67) and self-reported nonbruxers (n = 75) took part in the study. For each patient, the following occlusal features were clinically assessed: retruded contact position (RCP) to intercuspal contact position (ICP) slide length ( 4 mm, a deep bite), horizontal overlap (> 4 mm was considered a large horizontal overlap), incisor dental midline discrepancy (bruxism (dependent variable). Accuracy values to predict self-reported bruxism were unacceptable for all occlusal variables. The only variable remaining in the final regression model was laterotrusive interferences (P = .030). The percentage of explained variance for bruxism by the final multiple regression model was 4.6%. This model including only one occlusal factor showed low positive (58.1%) and negative predictive values (59.7%), thus showing a poor accuracy to predict the presence of self-reported bruxism (59.2%). This investigation suggested that the contribution of occlusion to the differentiation between bruxers and nonbruxers is negligible. This finding supports theories that advocate a much diminished role for peripheral anatomical-structural factors in the pathogenesis of bruxism.

  6. Sexual Orientation, Objective Height, and Self-Reported Height.

    Science.gov (United States)

    Skorska, Malvina N; Bogaert, Anthony F

    2017-01-01

    Studies that have used mostly self-reported height have found that androphilic men and women are shorter than gynephilic men and women, respectively. This study examined whether an objective height difference exists or whether a psychosocial account (e.g., distortion of self-reports) may explain these putative height differences. A total of 863 participants, recruited at a Canadian university, the surrounding region, and through lesbian, gay, bisexual, and transgender (LGBT) events across Canada, self-reported their height and had their height measured. Androphilic men were shorter, on average, than gynephilic men. There was no objective height difference between gynephilic, ambiphilic, and androphilic women. Self-reported height, statistically controlling for objective height, was not related to sexual orientation. These findings are the first to show an objective height difference between androphilic and gynephilic men. Also, the findings suggest that previous studies using self-reported height found part of a true objective height difference between androphilic and gynephilic men. These findings have implications for existing biological theories of men's sexual orientation development.

  7. Self-reported impulsivity and inhibitory control in problem gamblers.

    Science.gov (United States)

    Lorains, Felicity K; Stout, Julie C; Bradshaw, John L; Dowling, Nicki A; Enticott, Peter G

    2014-01-01

    Impulsivity is considered a core feature of problem gambling; however, self-reported impulsivity and inhibitory control may reflect disparate constructs. We examined self-reported impulsivity and inhibitory control in 39 treatment-seeking problem gamblers and 41 matched controls using a range of self-report questionnaires and laboratory inhibitory control tasks. We also investigated differences between treatment-seeking problem gamblers who prefer strategic (e.g., sports betting) and nonstrategic (e.g., electronic gaming machines) gambling activities. Treatment-seeking problem gamblers demonstrated elevated self-reported impulsivity, more go errors on the Stop Signal Task, and a lower gap score on the Random Number Generation task than matched controls. However, overall we did not find strong evidence that treatment-seeking problem gamblers are more impulsive on laboratory inhibitory control measures. Furthermore, strategic and nonstrategic problem gamblers did not differ from their respective controls on either self-reported impulsivity questionnaires or laboratory inhibitory control measures. Contrary to expectations, our results suggest that inhibitory dyscontrol may not be a key component for some treatment-seeking problem gamblers.

  8. Instrument Design of the Large Aperture Solar UV Visible and IR Observing Telescope (SUVIT) for the SOLAR-C Mission

    Science.gov (United States)

    Suematsu, Y.; Katsukawa, Y.; Shimizu, T.; Ichimoto, K.; Takeyama, N.

    2012-12-01

    We present an instrumental design of one major solar observation payload planned for the SOLAR-C mission: the Solar Ultra-violet Visible and near IR observing Telescope (SUVIT). The SUVIT is designed to provide high-angular-resolution investigation of the lower solar atmosphere, from the photosphere to the uppermost chromosphere, with enhanced spectroscopic and spectro-polarimetric capability in wide wavelength regions from 280 nm (Mg II h&k lines) to 1100 nm (He I 1083 nm line) with 1.5 m class aperture and filtergraphic and spectrographic instruments.

  9. Calibration of self-report tools for physical activity research: the Physical Activity Questionnaire (PAQ).

    Science.gov (United States)

    Saint-Maurice, Pedro F; Welk, Gregory J; Beyler, Nicholas K; Bartee, Roderick T; Heelan, Kate A

    2014-05-16

    The utility of self-report measures of physical activity (PA) in youth can be greatly enhanced by calibrating self-report output against objectively measured PA data.This study demonstrates the potential of calibrating self-report output against objectively measured physical activity (PA) in youth by using a commonly used self-report tool called the Physical Activity Questionnaire (PAQ). A total of 148 participants (grades 4 through 12) from 9 schools (during the 2009-2010 school year) wore an Actigraph accelerometer for 7 days and then completed the PAQ. Multiple linear regression modeling was used on 70% of the available sample to develop a calibration equation and this was cross validated on an independent sample of participants (30% of sample). A calibration model with age, gender, and PAQ scores explained 40% of the variance in values for the percentage of time in moderate-to-vigorous PA (%MVPA) measured from the accelerometers (%MVPA = 14.56 - (sex*0.98) - (0.84*age) + (1.01*PAQ)). When tested on an independent, hold-out sample, the model estimated %MVPA values that were highly correlated with the recorded accelerometer values (r = .63) and there was no significant difference between the estimated and recorded activity values (mean diff. = 25.3 ± 18.1 min; p = .17). These results suggest that the calibrated PAQ may be a valid alternative tool to activity monitoring instruments for estimating %MVPA in groups of youth.

  10. Designing instrumented walker to measure upper-extremity's efforts: A case study.

    Science.gov (United States)

    Khodadadi, Mohammad; Baniasad, Mina Arab; Arazpour, Mokhtar; Farahmand, Farzam; Zohoor, Hassan

    2018-02-26

    The high prevalence of shoulder pain in using walkers in patients who have spinal cord injury (SCI). Also, the limited options available to economically measure grip forces in walkers, which drove the need to create one. This article describes a method to obtain upper-extremities' forces and moments in a person with SCI by designing an appropriate instrumented walker. First, since the commercial multidirectional loadcells are too expensive, custom loadcells are fabricated. Ultimately, a complete gait analysis by means of VICON motion analysis and using inverse dynamic method has been held to measure upper-extremities' efforts. The results for a person with SCI using a two-wheel walker in low and high heights and a basic walker show that there are higher shoulder and elbow flexion-extension moments and also higher shoulder forces in superior-inferior direction and higher elbow and wrist forces in anterior-posterior directions. The results are not much different in using two different types of walker. By using the proposed method, upper-extremities' forces and moments were obtained and the results were compared to each other in using two different walkers.

  11. The impact of twenty years of noise research on nuclear power plant design, instrumentation and control

    International Nuclear Information System (INIS)

    Kemeny, L.G.

    1975-01-01

    Early investigations demonstrated that time constants and the dynamic characteristics of low energy nuclear systems could be elegantly determined by correlation of spectral analysis of fluctuating signals from ion chambers and proportional counters. Analyses of the time series information and the multi-filtering operations in the frequency domain were time consuming and tedious projects due to the lack of suitable data processing equipment. During the last decade, the significant advances were the recognition of the advantages of the two-channel cross-correlation technique and the realisation that the dynamic behaviour of nuclear power plant at power could be monitored and studied in depth by the cross-correlation of mechanical, thermal and hydrodynamic signals with neutronic information. The former concept led to the development of theoretical models for spatial and energy-dependent noise fields within a nuclear system. The latter opened a floodgate of potential advances in nuclear power plant design optimization, control and safety instrumentation, and control and safety diagnostic systems. (U.K.)

  12. Design and implementation of quench detection instrumentation for TF magnet system of SST-1

    International Nuclear Information System (INIS)

    Khristi, Y.; Sharma, A.N.; Doshi, K.; Banaudha, M.; Prasad, U.; Varmora, P.; Patel, D.; Pradhan, S.

    2014-01-01

    Steady State Superconducting Tokamak-1 (SST-1) at Institute for Plasma Research (IPR), India is now in engineering validation phase. The assembled Toroidal Field (TF) magnet system of SST-1 will be operated at 10 kA of nominal current at helium cooled condition of 4.5 K. A reliable and fail proof quench detection (QD) system is essential for the safety and the investment protection requirements of the magnets. This QD system needs to continuously monitor all the superconducting coils, which include 16 TF magnets, return-loop, bus bars and current leads. In case of any event initiating the normal resistive zone and reaching thermal run-away, the QD system needs to trigger the magnet protection circuits. Precision instrumentation and control system with 204 signal channels had been developed for detection of quench anywhere in the entire TF magnet system. In the present configuration of quench detection scheme, the voltage drop across each double pancake (DP) of each TF coil are compared with its two adjacent DPs for the detection of normal zone and cancelation of inductive couples. Two identical redundant systems with one out of two configurations are successfully commissioned and tested at IPR. This paper describes the design and implementation of the QD system, Installation experience, validation test and initial results from the recent SST-1 magnet system charging

  13. The Design and Manufacturing Report of Plug Type Non-Instrumented Rig for Irradiation Test in HANARO OR Hole

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Bang, Je Geon; Lim, Ik Sung; Kim, Sun Ki; Yang, Yong Sik; Song, Kun Woo

    2008-09-15

    This project is developed the plug type non-instrumented irradiation test rig of the advanced nuclear fuel in HANARO for pursuit advanced performance in High Performance Fuel Technology Development as a part Nuclear Mid and Long-term R and D Program. This irradiation rig was confirmed the integrity and HANARO core compatibility by the optimum design and the thermal hydraulic out-pile test in FIVPET. The characteristic of plug type non-instrument rig is to possible irradiation test of variable in-pile condition and reduced the wastes for reusable as function. This plug type non-instrumented rig was satisfied the quality assurance requirements and written out the end of manufacturing report. This plug type non-instrumented rig is adopt to the irradiation test for nuclear fuel irradiation test in HANARO OR hole.

  14. High-temperature gas-cooled reactor steam-cycle/cogeneration lead plant. Plant Protection and Instrumentation System design description

    International Nuclear Information System (INIS)

    1983-01-01

    The Plant Protection and Instrumentation System provides plant safety system sense and command features, actuation of plant safety system execute features, preventive features which maintain safety system integrity, and safety-related instrumentation which monitors the plant and its safety systems. The primary function of the Plant Protection and Instrumentation system is to sense plant process variables to detect abnormal plant conditions and to provide input to actuation devices directly controlling equipment required to mitigate the consequences of design basis events to protect the public health and safety. The secondary functions of the Plant Protection and Instrumentation System are to provide plant preventive features, sybsystems that monitor plant safety systems status, subsystems that monitor the plant under normal operating and accident conditions, safety-related controls which allow control of reactor shutdown and cooling from a remote shutdown area

  15. Measuring Literary Reading Motivation: Questionnaires Design and Pilot Testing

    Science.gov (United States)

    Chrysos, Michail

    2017-01-01

    This study aims to present the design and pilot testing procedures of the two specific self-report questionnaires were used to measure the two key aspects of reading motivation, self-efficacy and intrinsic motivation in the field of literary (narrative) reading, and the partial factors that jointly shape them. These instruments were outlined in…

  16. Cascading of molecular logic gates for advanced functions: a self-reporting, activatable photosensitizer.

    Science.gov (United States)

    Erbas-Cakmak, Sundus; Akkaya, Engin U

    2013-10-18

    Logical progress: Independent molecular logic gates have been designed and characterized. Then, the individual molecular logic gates were coerced to work together within a micelle. Information relay between the two logic gates was achieved through the intermediacy of singlet oxygen. Working together, these concatenated logic gates result in a self-reporting and activatable photosensitizer. GSH=glutathione. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Motivation and Pleasure Scale-Self-Report (MAP-SR): Validation of the German version of a self-report measure for screening negative symptoms in schizophrenia.

    Science.gov (United States)

    Engel, Maike; Lincoln, Tania Marie

    2016-02-01

    Validated self-report instruments could provide a time efficient screening method for negative symptoms in people with schizophrenia. The aim of this study was to examine the psychometric properties of a German version of the Motivation and Pleasure Scale-Self-Report (MAP-SR) which is based on the Clinical Assessment Interview for Negative Symptoms (CAINS). In- and outpatients (N=50) with schizophrenia or schizoaffective disorder were assessed with standardized interviews and questionnaires on negative and positive symptoms and general psychopathology in schizophrenia, depression, and global functioning. The German version of the MAP-SR showed high internal consistency. Convergent validity was supported by significant correlations between the MAP-SR with the experience sub-scale of the CAINS and the negative symptom sub-scale of the Positive and Negative Syndrome Scale. The MAP-SR also exhibited discriminant validity indicated by its non-significant correlations with positive symptoms and general psychopathology, which is in line with the findings for the original version of the MAP-SR. However, the MAP-SR correlated moderately with depression. The German MAP-SR appears to be a valid and suitable diagnostic tool for the identification of negative symptoms in schizophrenia. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Absolute measurement of LDR brachytherapy source emitted power: Instrument design and initial measurements.

    Science.gov (United States)

    Malin, Martha J; Palmer, Benjamin R; DeWerd, Larry A

    2016-02-01

    Energy-based source strength metrics may find use with model-based dose calculation algorithms, but no instruments exist that can measure the energy emitted from low-dose rate (LDR) sources. This work developed a calorimetric technique for measuring the power emitted from encapsulated low-dose rate, photon-emitting brachytherapy sources. This quantity is called emitted power (EP). The measurement methodology, instrument design and performance, and EP measurements made with the calorimeter are presented in this work. A calorimeter operating with a liquid helium thermal sink was developed to measure EP from LDR brachytherapy sources. The calorimeter employed an electrical substitution technique to determine the power emitted from the source. The calorimeter's performance and thermal system were characterized. EP measurements were made using four (125)I sources with air-kerma strengths ranging from 2.3 to 5.6 U and corresponding EPs of 0.39-0.79 μW, respectively. Three Best Medical 2301 sources and one Oncura 6711 source were measured. EP was also computed by converting measured air-kerma strengths to EPs through Monte Carlo-derived conversion factors. The measured EP and derived EPs were compared to determine the accuracy of the calorimeter measurement technique. The calorimeter had a noise floor of 1-3 nW and a repeatability of 30-60 nW. The calorimeter was stable to within 5 nW over a 12 h measurement window. All measured values agreed with derived EPs to within 10%, with three of the four sources agreeing to within 4%. Calorimeter measurements had uncertainties ranging from 2.6% to 4.5% at the k = 1 level. The values of the derived EPs had uncertainties ranging from 2.9% to 3.6% at the k = 1 level. A calorimeter capable of measuring the EP from LDR sources has been developed and validated for (125)I sources with EPs between 0.43 and 0.79 μW.

  19. Non-instrumented capsule design of HANARO irradiation test for the high burn-up large grain UO2 pellets

    International Nuclear Information System (INIS)

    Kim, D. H.; Lee, C. B.; Oh, D. S.

    2001-01-01

    Non-instrumented capsule was designed to irradiate the large grain UO 2 pellet developed for the high burn-up LWR fuel in the HANARO in-pile capsule. UO 2 pelletes will be irradiated up to the burn-up higher than 70 MWD/kgU in HANARO. To irradiate the UO 2 pellets up to the burn-up 70 MWD/kgU, need the time about 60 months and ensure the integrity of non-instrumented capsule for 30 months until replace the new capsule. In addition, to satisfy the safety criteria of HANARO such as prevention of ONB(Onset of Nucleate Boiling), fuel melting and wear damage of the capsule during the long term irradiation, design of the non-instrumented capsule was optimized

  20. Engineering design of the Regolith X-ray Imaging Spectrometer (REXIS) instrument: an OSIRIS-REx student collaboration

    Science.gov (United States)

    Jones, Michael; Chodas, Mark; Smith, Matthew J.; Masterson, Rebecca A.

    2014-07-01

    OSIRIS-REx is a NASA New Frontiers mission scheduled for launch in 2016 that will travel to the asteroid Bennu and return a pristine sample of the asteroid to Earth. The REgolith X-ray Imaging Spectrometer (REXIS) is a student collaboration instrument on-board the OSIRIS-REx spacecraft. REXIS is a NASA risk Class D instrument, and its design and development is largely student led. The engineering team consists of MIT graduate and undergraduate students and staff at the MIT Space Systems Laboratory. The primary goal of REXIS is the education of science and engineering students through participation in the development of light hardware. In light, REXIS will contribute to the mission by providing an elemental abundance map of the asteroid and by characterizing Bennu among the known meteorite groups. REXIS is sensitive to X-rays between 0.5 and 7 keV, and uses coded aperture imaging to map the distribution of iron with 50 m spatial resolution. This paper describes the science goals, concept of operations, and overall engineering design of the REXIS instrument. Each subsystem of the instrument is addressed with a high-level description of the design. Critical design elements such as the Thermal Isolation Layer (TIL), radiation cover, coded-aperture mask, and Detector Assembly Mount (DAM) are discussed in further detail.

  1. Design and development of an instrument to measure radiative absorption of seawater. Sumarad

    International Nuclear Information System (INIS)

    Fasano, G.; Materassi, A.

    2003-01-01

    In the present work, a low-cost instrument is presented that provides the ratio between underwater radiation and radiation outside water for the four spectral ranges fundamental for photosynthetic activity (Sub Marine Radiometer). The instrument essentially consists of two radiometers which operate in the same four bands: one acquires radiation outside the water, the other underwater radiation at a pre-established depth. The two acquisition systems are synchronized when the instrument is turned on and then, in the course of data elaboration, the ratio is obtained between underwater and outside water radiation for each spectral band, at any determined moment, at a predetermined depth. This ratio, in accordance with the Beer-Lambert equation, represents the transmittance of the medium crossed by radiation. By applying the Linke equation to collected data, it is also possible to determine the turbidity of the considered medium. The system can acquire as many as 1,472 data, with programmable temporal scanning, and can operate at depths up to 50 meters. Applications of this instrument are already in progress in studies concerning the relationship between solar radiation and photosynthetic activity of Posidonia oceanica. The proposed instrument has a relatively low cost, when compared with that of other instruments currently on the market, making it particularly suitable for applications that require numerous instruments to monitor sea, lacustrine or fluvial water in various points at the same time [it

  2. Self-reported non-adherence and beliefs about medication in a Swedish kidney transplant population.

    Science.gov (United States)

    Lennerling, Annette; Forsberg, Anna

    2012-01-01

    Patients' non-adherence to immunosuppressant treatment after organ transplantation may lead to organ failure, graft loss and death. Non-adherence among Swedish kidney transplant recipients has not previously been studied. Hence the aim of this study was to explore non-adherence among Swedish kidney transplant recipients by using self-report instruments as well as testing the hypothesis that there is a difference in self-reported symptoms, beliefs about medicine and social support between respondents with or without self reported non-adherence. In the present cross sectional study 250 renal transplant recipients participated by replying to a questionnaire. Two validated instruments were included, one on beliefs about medicine (the BMQ©), the other on nonadherence (the BAASIS©). Only 46 % never failed to follow the medical treatment with respect to taking the drugs, dosage or timing (>2 hrs from prescribed time). Timing was the most frequently reported deviation (48 %). Forty-seven patients (16 %) had failed taking at least one dose of the prescribed immunosuppressants during the past four weeks. Four individuals had reduced the prescribed doses. Only one reported taking a 'drug holiday'. Nine participants reported stronger concerns than necessities for immunosuppressive medication. For the BMQ the necessity scores were extremely high while the scores for concern were low. Risk behaviour identified by the BAASIS had no association in risk attitudes as identified in the BMQ. The only factor relating to non-adherence was lack of social support (p=0.022). In general adherence was high. Identification of the exceptions remains a challenge.

  3. Psychometric evaluation of self-report outcome measures for prosthetic applications.

    Science.gov (United States)

    Hafner, Brian J; Morgan, Sara J; Askew, Robert L; Salem, Rana

    2016-01-01

    Documentation of clinical outcomes is increasingly expected in delivery of prosthetic services and devices. However, many outcome measures suitable for use in clinical care and research have not been psychometrically tested with prosthesis users. The aim of this study was to determine test-retest reliability, mode-of-administration (MoA) equivalence, standard error of measurement (SEM), and minimal detectable change (MDC) of standardized, self-report instruments that assess constructs of importance to people with lower limb loss. Prosthesis users (n = 201) were randomly assigned to groups based on MoA (i.e., paper, electronic, or mixed-mode). Participants completed two surveys 2 to 3 d apart. Instruments included the Prosthetic Limb Users Survey of Mobility, Prosthesis Evaluation Questionnaire-Mobility Subscale, Activities-Specific Balance Confidence Scale, Quality of Life in Neurological Conditions-Applied Cognition/General Concerns, Patient-Reported Outcomes Measurement Information System Profile, and Socket Comfort Score. Intraclass correlation coefficients indicated all instruments are appropriate for group-level comparisons and select instruments are suitable for individual-level applications. Several instruments showed evidence of possible floor and ceiling effects. All were equivalent across MoAs. SEM and MDC were quantified to facilitate interpretation of outcomes and change scores. These results can enhance clinicians' and researchers' ability to select, apply, and interpret scores from instruments administered to prosthesis users.

  4. Is there an association between rumination and self-reported physical health? A one-year follow-up in a young and an elderly sample

    DEFF Research Database (Denmark)

    Thomsen, Dorthe Kirkegaard; Mehlsen, Mimi Yung; Olesen, Frede

    2004-01-01

    Cross-sectional studies have suggested an association between rumination and subjective health. The aim of the present study was to investigate in a longitudinal design whether rumination was related to self-reported physical health. A total of 96 young (age range 20-35) and 110 elderly (age range...... 70-85) participants completed questionnaires measuring rumination, negative affect, life events, and self-reported physical health at baseline and at 1-year follow-up. Multiple linear regressions showed a significant association between self-reported physical health at time I only for the elderly...... and negative affect mediated the association. At follow-up, rumination was significantly associated with self-reported physical health only for the young and the association was only partly mediated by negative affect. In conclusion, rumination is associated with poorer self-reported physical health...

  5. An instrument design and sample strategy for measuring soil respiration in the coastal temperate rain forest

    Science.gov (United States)

    Nay, S. M.; D'Amore, D. V.

    2009-12-01

    The coastal temperate rainforest (CTR) along the northwest coast of North America is a large and complex mosaic of forests and wetlands located on an undulating terrain ranging from sea level to thousands of meters in elevation. This biome stores a dynamic portion of the total carbon stock of North America. The fate of the terrestrial carbon stock is of concern due to the potential for mobilization and export of this store to both the atmosphere as carbon respiration flux and ocean as dissolved organic and inorganic carbon flux. Soil respiration is the largest export vector in the system and must be accurately measured to gain any comprehensive understanding of how carbon moves though this system. Suitable monitoring tools capable of measuring carbon fluxes at small spatial scales are essential for our understanding of carbon dynamics at larger spatial scales within this complex assemblage of ecosystems. We have adapted instrumentation and developed a sampling strategy for optimizing replication of soil respiration measurements to quantify differences among spatially complex landscape units of the CTR. We start with the design of the instrument to ease the technological, ergonomic and financial barriers that technicians encounter in monitoring the efflux of CO2 from the soil. Our sampling strategy optimizes the physical efforts of the field work and manages for the high variation of flux measurements encountered in this difficult environment of rough terrain, dense vegetation and wet climate. Our soil respirometer incorporates an infra-red gas analyzer (LiCor Inc. LI-820) and an 8300 cm3 soil respiration chamber; the device is durable, lightweight, easy to operate and can be built for under $5000 per unit. The modest unit price allows for a multiple unit fleet to be deployed and operated in an intensive field monitoring campaign. We use a large 346 cm2 collar to accommodate as much micro spatial variation as feasible and to facilitate repeated measures for tracking

  6. The design of a simple radon-detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Du Genyuan; Qiu Yingyu; Zhang Jiang

    2007-01-01

    Introduction are given on the internal composition of the radon-detecting instrument based on MCU and the working of the real electric circuit. The single-chip microcomputer P89C58 of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  7. The design of a simple radon-detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Du Genyuan; Chen Jianjun; Zhang Jiang

    2008-01-01

    Introduction are given on the internal composition of the radon-detecting instrument based on MCU and the working of the real electric circuit. The single-chip microcomputer P89C58 of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  8. The design of a simple portable γ ray detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Liu Chunmei; Cao Wen; Zhang Jiang

    2008-01-01

    The internal composition of the γ ray detecting instrument based on MCU and the working of the real electric circuit are introduced. The single-chip microcomputer of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  9. The design of an instrumented rebar for assessment of corrosion in cracked reinforced concrete

    DEFF Research Database (Denmark)

    Pease, Bradley Justin; Geiker, Mette Rica; Stang, Henrik

    2011-01-01

    rebar with 17 electronically isolated corrosion sensors. Instrumented and standard rebars were cast into concrete beams and bending cracks were induced and held open using steel frames. Epoxy impregnation was used to assess and compare cracks in the concrete around the instrumented and standard rebar...... between the steel and concrete. Cracked beams with cast-in instrumented and standard rebars were ponded with a 10\\% chloride solution and the open circuit corrosion potential (OCP) of the 17 sensors was measured for up to 62 days. Measurements from the individual sensors indicate when and where active...

  10. The age distribution of self-reported personality disorder traits in a household population.

    Science.gov (United States)

    Ullrich, Simone; Coid, Jeremy

    2009-04-01

    Stability over time is an essential criterion for the diagnosis of a personality disorder (PD) according to DSM-IV and ICD-10. However, both longitudinal and cross-sectional studies have demonstrated considerable changes of personality disorder traits during life-span, an observation which challenges this assumption. We measured self-reported DSM-IV personality disorder traits in a nationally representative community sample using a cross-sectional design. We investigated the association of dimensional PD scores with age. Our analyses confirmed a decreasing prevalence of personality disorder mean scores across age groups in the population, particularly Cluster B, with an increase in self-reported schizoid and obsessive-compulsive scores. Furthermore, specific interactions of demographic characteristics and age were identified. Analyses of transition points in the distribution of personality disorders across different age groups did not demonstrate increasing stability after age 30 as previously observed for normal personality traits. Significant changes occurred primarily after the third decade.

  11. Handling uncertainty in bioenergy policy design – A case study analysis of UK and German bioelectricity policy instruments

    International Nuclear Information System (INIS)

    Purkus, Alexandra; Röder, Mirjam; Gawel, Erik; Thrän, Daniela; Thornley, Patricia

    2015-01-01

    In designing policies to promote bioenergy, policy makers face challenges concerning uncertainties about the sustainability of bioenergy pathways (including greenhouse gas balances), technology and resource costs, or future energy market framework conditions. New information becomes available with time, but policy adjustments can involve high levels of adaptation costs. To enable an effective steering of technology choices and innovation, policies have to strike a balance between creating a consistent institutional framework, which establishes planning security for investors, and sufficient flexibility to adapt to new information. This paper examines implications of economic theory for handling cost and benefit uncertainty in bioelectricity policy design, focussing on choices between price and quantity instruments, technology differentiation, and policy adjustment. Findings are applied to two case studies, the UK's Renewables Obligation and the German feed-in tariff/feed-in premium scheme. Case study results show the trade-offs that are involved in instrument choice and design – depending on political priorities and a country's specific context, different options can prove more adequate. Combining market-based remuneration with sustainability criteria results in strong incentives for bioenergy producers to search for low-cost solutions; whereas cost-based price instruments with centrally steered technology and feedstock choices offer higher planning security for investors and more direct control for policy makers over what pathways are implemented. Independent of the choice of instrument type and technology differentiation mechanism, findings emphasise the importance of a careful policy design, which determines the exact balance between performance criteria such as cost control, incentive intensity, planning security and adaptive efficiency. - Highlights: • Bioelectricity policy design must deal with simultaneous cost and benefit uncertainty.

  12. A Scoping Review of Self-Report Measures of Aggression and Bullying for Use With Preadolescent Children.

    Science.gov (United States)

    Nelson, Helen J; Kendall, Garth E; Burns, Sharyn K; Schonert-Reichl, Kimberly A

    2017-02-01

    Bullying in schools is a major health concern throughout the world, contributing to poor educational and mental health outcomes. School nurses are well placed to facilitate the implementation and evaluation of bullying prevention strategies. To evaluate the effect of such strategies, it is necessary to measure children's behavior over time. This scoping review of instruments that measure the self-report of aggressive behavior and bullying by children will inform the evaluation of bullying interventions. This review aimed to identify validated instruments that measure aggression and bullying among preadolescent children (age 8-12). The review was part of a larger study that sought to differentiate bullying from aggressive behavior by measuring the self-report of power imbalance between the aggressor and the child being bullied. The measurement of power imbalance was therefore a key aspect of the scoping review.

  13. The design of an instrument to evaluate software for EFL/ESL pronunciation teaching

    Directory of Open Access Journals (Sweden)

    Cristiana Gomes de Freitas Menezes Martins

    2016-01-01

    Full Text Available http://dx.doi.org/10.5007/2175-8026.2016v69n1p141 The purpose of this study was to develop and test the reliability and validity of an instrument to evaluate the extent to which software programs teach English as a Foreign Language and/or Second Language (EFL/ESL pronunciation following the principles of the Communicative Approach (Celce-Murcia et al, 2010, thus having the potential to develop English pronunciation. After the development of the instrument, 46 EFL/ESL teachers used it to analyze an online version of the software program Pronunciation Power 2. The responses of the participants were submitted to statistical analysis and the validity and reliability of the instrument were tested. The good reliability indexes obtained in this study suggest the instrument has some degree of validity for evaluating how well an ESL/EFL pronunciation teaching software program potentially develops English pronunciation.

  14. A new radiometric instrument designed to measure the parameters of bituminous coal on transport belts

    International Nuclear Information System (INIS)

    Kubicek, P.

    1993-01-01

    A new radiometric instrument developed in Czechoslovakia, for the measurement of ash content of bituminous coal, and for the determination of approximate values of moisture and weight is described. (Author)

  15. Design and quality assurance of control and instrumentation systems, licensing practice in Austria

    International Nuclear Information System (INIS)

    Fasko, Peter.

    1978-01-01

    The practicised way how licensing of control and instrumentation systems is performed in Austria, is related. As there is no national regulations in Austria for licensing nuclear power plants, it tries to adopt international regulations for its own purpose. (author)

  16. Self-reported acne is not associated with prostate cancer

    NARCIS (Netherlands)

    Cremers, R.G.; Aben, K.K.; Verrneulen, S.H.; den Heijer, M.; van Oort, I.M.; van de Kerkhof, P.C.; Schalken, JA; Kiemeney, L.A.

    2014-01-01

    Objective: Some studies have suggested an inverse association between acne vulgaris and the acne-related bacterium Propionibacterium acnes and prostate cancer (PCa). Self-reported acne might be an easily obtainable marker to identify men at relatively low risk of PCa and might be incorporated into

  17. Self-reported acne is not associated with prostate cancer

    NARCIS (Netherlands)

    Cremers, R.G.H.M.; Aben, K.K.H.; Vermeulen, S.; Heijer, M. den; Oort, I.M. van; Kerkhof, P.C.M. van de; Schalken, J.A.; Kiemeney, L.A.L.M.

    2014-01-01

    OBJECTIVE: Some studies have suggested an inverse association between acne vulgaris and the acne-related bacterium Propionibacterium acnes and prostate cancer (PCa). Self-reported acne might be an easily obtainable marker to identify men at relatively low risk of PCa and might be incorporated into

  18. Children's self-reported pain at the dentist

    NARCIS (Netherlands)

    Versloot, J.; Veerkamp, J.S.J.; Hoogstraten, J.

    2008-01-01

    The aim of the present study is to get an insight into the pain report of children over two sequential dental visits. Furthermore, it was studied whether age, previous dental experience, level of dental anxiety and injection site were of influence on the self-reported pain of children during the

  19. Readability of Self-Report Measures of Depression and Anxiety

    Science.gov (United States)

    McHugh, R. Kathryn; Behar, Evelyn

    2009-01-01

    As the demand for accountability in service provision settings increases, the need for valid methods for assessing clinical outcomes is of particular importance. Self-report measures of functioning are particularly useful in the assessment of psychological functioning, but a vital factor in their validity and transportability is the reading level…

  20. Validation of self-reported cellular phone use

    DEFF Research Database (Denmark)

    Samkange-Zeeb, Florence; Berg, Gabriele; Blettner, Maria

    2004-01-01

    BACKGROUND: In recent years, concern has been raised over possible adverse health effects of cellular telephone use. In epidemiological studies of cancer risk associated with the use of cellular telephones, the validity of self-reported cellular phone use has been problematic. Up to now there is ......BACKGROUND: In recent years, concern has been raised over possible adverse health effects of cellular telephone use. In epidemiological studies of cancer risk associated with the use of cellular telephones, the validity of self-reported cellular phone use has been problematic. Up to now...... there is very little information published on this subject. METHODS: We conducted a study to validate the questionnaire used in an ongoing international case-control study on cellular phone use, the "Interphone study". Self-reported cellular phone use from 68 of 104 participants who took part in our study...... was compared with information derived from the network providers over a period of 3 months (taken as the gold standard). RESULTS: Using Spearman's rank correlation, the correlation between self-reported phone use and information from the network providers for cellular phone use in terms of the number of calls...

  1. Smoking Habit and Self Reported Periodontal Treatment Experience ...

    African Journals Online (AJOL)

    This study ai 's to determine by questionnaire the prevalence of smoking and its associated sociodemographic factors in adult dentate populations in Southwestern Nigeria and to examine self reported periodontal treatment experience between smokers and nonsmokers. A descriptive study of prevalence of smoking and ...

  2. Prevalence of self-reported hypertension and diabetes and ...

    African Journals Online (AJOL)

    Prevalence of self-reported hypertension and diabetes and associated risk factors among university employees in Jos, Nigeria. ... Concerted efforts to implement NCD prevention measures will serve to reduce the high burden of NCDs. Keywords: Non-communicable disease, Diabetes mellitus, Hypertension, Lifestyle, risk ...

  3. Self-reported adverse effects as barriers to adherence to ...

    African Journals Online (AJOL)

    Conclusions: In conclusion, self-reported barriers to optimal adherence included the use of non-prescribed drugs, and the presence of side effects such as insomnia, headaches and abdominal pain; while eating well was a facilitator. These findings emphasise the need for better communication between patients and ...

  4. A Self-Report Measure of Assertiveness in Young Adolescents.

    Science.gov (United States)

    Connor, Jane M.; And Others

    1982-01-01

    Reported a self-report measure of adolescents' assertiveness. Items for the scale were presented to sixth-grade students. Factor analysis revealed factors of submissiveness, aggressiveness, and assertiveness. After the validational study, a small assertiveness training program indicated that training effects were obtained and could be generalized…

  5. Can Assertiveness be Distinguished From Aggressiveness Using Self Report Data?

    Science.gov (United States)

    Mauger, Paul A.; And Others

    The differences between aggressiveness and assertiveness were examined using the Interpersonal Behavior Survey (IBS), a 136-item self-report questionnaire which was developed to distinguish between assertive and aggressive behaviors. Item level factor analysis was used in scale construction. Results indicated that: (1) the correlation between the…

  6. Reliability of self-reported eating disorders : Optimizing population screening

    NARCIS (Netherlands)

    Keski-Rahkonen, Anna; Sihvola, Elina; Raevuori, Anu; Kaukoranta, Jutta; Bulik, Cynthia M.; Hoek, Hans W.; Rissanen, Aila; Kaprio, Jaakko

    2006-01-01

    Objective: The objective of this study was to assess whether short self-report eating disorder screening questions are useful population screening methods. Method: We screened the female participants (N = 2881) from the 1975-1079 birth cohorts of Finnish twins for eating disorders, using several

  7. The Self-Report Family Inventory: An Exploratory Factor Analysis

    Science.gov (United States)

    Goodrich, Kristopher M.; Selig, James P.; Trahan, Don P., Jr.

    2012-01-01

    Researchers explored the factor structure of the Self-Report Family Inventory with a sample of heterosexual parents who have a son or daughter who self-identifies as lesbian, gay, or bisexual. Results suggest that a two-factor solution is appropriate. Research and clinical implications are offered. (Contains 1 figure and 2 tables.)

  8. Assessing the Accuracy of Self-Reported Self-Talk

    Directory of Open Access Journals (Sweden)

    Thomas M. Brinthaupt

    2015-05-01

    Full Text Available Self-Talk Scale (STS; Brinthaupt, Hein, & Kramer, 2009 is a self-report measure of self-talk frequency that has been shown to possess acceptable reliability and validity. However, no research using the STS has examined the accuracy of respondents’ self-reports. In the present paper, we report a series of studies directly examining the measurement of self-talk frequency and functions using the STS. The studies examine ways to validate self-reported self-talk by (1 comparing STS responses from 6 weeks earlier to recent experiences that might precipitate self-talk, (2 using experience sampling methods to determine whether STS scores are related to recent reports of self-talk over a period of a week, and (3 comparing self-reported STS scores to those provided by a significant other who rated the target on the STS. Results showed that (1 overall self-talk scores, particularly self-critical and self-reinforcing self-talk, were significantly related to reports of context-specific self-talk; (2 high STS scorers reported talking to themselves significantly more often during recent events compared to low STS scorers, and, contrary to expectations, (3 friends reported less agreement than strangers in their self-other self-talk ratings. Implications of the results for the validity of the STS and for measuring self-talk are presented.

  9. Cultural values: can they explain self-reported health?

    NARCIS (Netherlands)

    Roudijk, B.; Donders, R.; Stalmeier, P.F.

    2017-01-01

    PURPOSE: Self-reported health (SRH) is a measure widely used in health research and population studies. Differences in SRH have been observed between countries and cultural values have been hypothesized to partly explain such differences. Cultural values can be operationalized by two cultural

  10. Cognitive Abilities Relate to Self-Reported Hearing Disability

    Science.gov (United States)

    Zekveld, Adriana A.; George, Erwin L. J.; Houtgast, Tammo; Kramer, Sophia E.

    2013-01-01

    Purpose: In this explorative study, the authors investigated the relationship between auditory and cognitive abilities and self-reported hearing disability. Method: Thirty-two adults with mild to moderate hearing loss completed the Amsterdam Inventory for Auditory Disability and Handicap (AIADH; Kramer, Kapteyn, Festen, & Tobi, 1996) and…

  11. Cognitive abilities relate to self-reported hearing disability

    NARCIS (Netherlands)

    Zekveld, A.A.; George, E.L.J.; Houtgast, T.; Kramer, S.E.

    2013-01-01

    Purpose: In this explorative study, the authors investigated the relationship between auditory and cognitive abilities and self-reported hearing disability. Method: Thirty-two adults with mild to moderate hearing loss completed the Amsterdam Inventory for Auditory Disability and Handicap (AIADH;

  12. Correlation between self-reported gestational age and ultrasound measurements

    DEFF Research Database (Denmark)

    Olesen, Annette Wind; Westergaard, Jes Grabow; Thomsen, Sten Grove

    2004-01-01

    BACKGROUND: We studied the agreement between different measurements of gestational age, i.e. self-reported gestational age in the Danish National Birth Cohort Study, ultrasound-estimated gestational age from the medical records in one Danish county and gestational age from the Danish National...

  13. Personality, psychological stress, and self-reported influenza symptomatology

    Directory of Open Access Journals (Sweden)

    Croon Marcel A

    2007-11-01

    Full Text Available Abstract Background Psychological stress and negative mood have been related to increased vulnerability to influenza-like illness (ILI. This prospective study re-evaluated the predictive value of perceived stress for self-reported ILI. We additionally explored the role of the negative affectivity and social inhibition traits. Methods In this study, 5,404 respondents from the general population were assessed in terms of perceived stress, personality, and control variables (vaccination, vitamin use, exercise, etc.. ILI were registered weekly using self-report measures during a follow-up period of four weeks. Results Multivariable logistic regression analysis on ILI was performed to test the predictive power of stress and personality. In this model, negative affectivity (OR = 1.05, p = 0.009, social inhibition (OR = 0.97, p = 0.011, and perceived stress (OR = 1.03, p = 0.048 predicted ILI reporting. Having a history of asthma (OR = 2.33, p = Conclusion Elderly and socially inhibited persons tend to report less ILI as compared to their younger and less socially inhibited counterparts. In contrast, asthma, trait negative affectivity, and perceived stress were associated with higher self-report of ILI. Our results demonstrate the importance of including trait markers in future studies examining the relation between stress and self-report symptom measures.

  14. Psychiatric Diagnoses of Self-Reported Child Abusers.

    Science.gov (United States)

    Dinwiddie, Stephen H.; Bucholz, Kathleen K.

    1993-01-01

    Subjects who self-reported episodes of abusing a child were compared to those without a history of child battery. It was concluded that self-identified child abusers have increased lifetime rates of antisocial personality disorder, alcoholism, and depression. (DB)

  15. Self-reported sexual behaviour among adolescent girls in Uganda ...

    African Journals Online (AJOL)

    Conclusion: Information about risk factors revealed in individual interviews and by the midwives taking a history was incongruent. Any approach for management of STIs, which is built on self-reported risk factors, needs careful assessment of reliability. Keywords: Adolescents, Risk factors, reliability, STI, Uganda

  16. pedometer-measured physical activity, self-reported physical activity

    African Journals Online (AJOL)

    between self-reported and pedometer-measured physical activity was also determined. Results. Average ... Methods. This was a cross-sectional study among employed South African adults. Participant ... acquired information on physical activity habits. Questions ..... How many days of monitoring predict physical activity and ...

  17. Predicting anxiety diagnoses with the youth self-report

    NARCIS (Netherlands)

    Ferdinand, Robert

    2007-01-01

    Empirical studies that assess which items of the Youth Self-Report (YSR) are the best predictors of anxiety disorders in adolescents are lacking, whereas several attempts have been made to construct an anxiety scale for the YSR. It is important to gap the bridge between existing YSR and DSM-IV

  18. Blouse sizing using self-reported body dimensions

    NARCIS (Netherlands)

    Daanen, Hein A M; Byvoet, Michel B.

    2011-01-01

    Purpose: The challenge for companies selling clothing over the internet is to combine a minimal requested effort of the visitor in entering (body) information with low-percentage no-fit returns. The purpose of this paper is to present a method that converts self-reported information to individual

  19. Design, development, and testing of the DCT Cassegrain instrument support assembly

    Science.gov (United States)

    Bida, Thomas A.; Dunham, Edward W.; Nye, Ralph A.; Chylek, Tomas; Oliver, Richard C.

    2012-09-01

    The 4.3m Discovery Channel Telescope delivers an f/6.1 unvignetted 0.5° field to its RC focal plane. In order to support guiding, wavefront sensing, and instrument installations, a Cassegrain instrument support assembly has been developed which includes a facility guider and wavefront sensor package (GWAVES) and multiple interfaces for instrumentation. A 2-element, all-spherical, fused-silica corrector compensates for field curvature and astigmatism over the 0.5° FOV, while reducing ghost pupil reflections to minimal levels. Dual roving GWAVES camera probes pick off stars in the outer annulus of the corrected field, providing simultaneous guiding and wavefront sensing for telescope operations. The instrument cube supports 5 co-mounted instruments with rapid feed selection via deployable fold mirrors. The corrected beam passes through a dual filter wheel before imaging with the 6K x 6K single CCD of the Large Monolithic Imager (LMI). We describe key development strategies for the DCT Cassegrain instrument assembly and GWAVES, including construction of a prime focus test assembly with wavefront sensor utilized in fall 2011 to begin characterization of the DCT primary mirror support. We also report on 2012 on-sky test results of wavefront sensing, guiding, and imaging with the integrated Cassegrain cube.

  20. Convergent and Discriminant Validity of Psychopathy Factors Assessed Via Self-Report

    Science.gov (United States)

    Benning, Stephen D.; Patrick, Christopher J.; Salekin, Randall T.; Leistico, Anne-Marie R.

    2008-01-01

    Psychopathy has been conceptualized as a personality disorder with distinctive interpersonal-affective and behavioral deviance features. The authors examine correlates of the factors of the Psychopathic Personality Inventory (PPI), Self-Report Psychopathy–II (SRP-II) scale, and Antisocial Process Screening Device (APSD) to understand similarities and differences among the constructs embodied in these instruments. PPI Fearless Dominance and SRP-II Factor 1 were negatively related to most personality disorder symptoms and were both predicted by high Dominance and low Neuroticism. In addition, PPI Fearless Dominance correlated positively with antisocial personality features, although SRP-II Factor 1 did not. In contrast, PPI Impulsive Antisociality, SRP-II Factor 2, and both APSD factors correlated with antisocial personality features and symptoms of nearly all personality disorders, and were predicted by low Love. Results suggest ways in which the measurement of the constructs in each instrument may be improved. PMID:16123248

  1. Design and Implementation of Electric Steering Gear Inspection System for Unmanned Aerial Vehicles Based on Virtual Instruments

    Directory of Open Access Journals (Sweden)

    Zheng Xing

    2016-01-01

    Full Text Available A kind of UAV electric servo detection system based on Virtual Instrument is designed in this paper, including the hardware platform based on PC-DAQ virtual instrument architecture and the software platform based on LabVIEW function, structure and system implementation methods. The function, structure and system implementation method of software platform is also described. The gear limits checking, zero testing, time domain characteristics test results showed that the system achieves testing requirements well, and can complete detection of electric steering gear automatically, fast, easy and accurate.

  2. Prevalence of mood and anxiety disorder in self reported irritable bowel syndrome (IBS). An epidemiological population based study of women

    OpenAIRE

    Mykletun, Arnstein; Jacka, Felice; Williams, Lana; Pasco, Julie; Henry, Margaret; Nicholson, Geoffrey C.; Kotowicz, Mark A.; Berk, Michael

    2010-01-01

    Abstract Background Irritable bowel syndrome (IBS) is commonly regarded as a functional disorder, and is hypothesized to be associated with anxiety and depression. This evidence mainly rests on population-based studies utilising self-report screening instruments for psychopathology. Other studies applying structured clinical interviews are generally based on small clinical samples, which are vulnerable to biases. The extant evidence base for an association between IBS and psychopathology is h...

  3. Self-report fatigue questionnaires in multiple sclerosis, Parkinson’s disease and stroke: a systematic review of measurement properties

    OpenAIRE

    Elbers, Roy G.; Rietberg, Marc B.; van Wegen, Erwin E. H.; Verhoef, John; Kramer, Sharon F.; Terwee, Caroline B.; Kwakkel, Gert

    2011-01-01

    Purpose To critically appraise, compare and summarize the measurement properties of self-report fatigue questionnaires validated in patients with multiple sclerosis (MS), Parkinson’s disease (PD) or stroke. Methods MEDLINE, EMBASE, PsycINFO, CINAHL and SPORTdiscus were searched. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist was used to assess the methodological quality of studies. A qualitative data synthesis was performed to rate the mea...

  4. Analysing the interactions between renewable energy promotion and energy efficiency support schemes: The impact of different instruments and design elements

    International Nuclear Information System (INIS)

    Rio, Pablo del

    2010-01-01

    CO 2 emissions reduction, renewable energy deployment and energy efficiency are three main energy/environmental goals, particularly in Europe. Their relevance has led to the implementation of support schemes in these realms. Their coexistence may lead to overlaps, synergies and conflicts between them. The aim of this paper is to analyse the interactions between energy efficiency measures and renewable energy promotion, whereas previous analyses have focused on the interactions between emissions trading schemes (ETS) and energy efficiency measures and ETS and renewable energy promotion schemes. Furthermore, the analysis in this paper transcends the 'certificate' debate (i.e., tradable green and white certificates) and considers other instruments, particularly feed-in tariffs for renewable electricity. The goal is to identify positive and negative interactions between energy efficiency and renewable electricity promotion and to assess whether the choice of specific instruments and design elements within those instruments affects the results of the interactions.

  5. Analysing the interactions between renewable energy promotion and energy efficiency support schemes: The impact of different instruments and design elements

    Energy Technology Data Exchange (ETDEWEB)

    Rio, Pablo del, E-mail: pablo.delrio@cchs.csic.e [Instituto de Politicas y Bienes Publicos, Consejo Superior de Investigaciones Cientificas (CSIC), C/Albasanz 26-28, 28037 Madrid (Spain)

    2010-09-15

    CO{sub 2} emissions reduction, renewable energy deployment and energy efficiency are three main energy/environmental goals, particularly in Europe. Their relevance has led to the implementation of support schemes in these realms. Their coexistence may lead to overlaps, synergies and conflicts between them. The aim of this paper is to analyse the interactions between energy efficiency measures and renewable energy promotion, whereas previous analyses have focused on the interactions between emissions trading schemes (ETS) and energy efficiency measures and ETS and renewable energy promotion schemes. Furthermore, the analysis in this paper transcends the 'certificate' debate (i.e., tradable green and white certificates) and considers other instruments, particularly feed-in tariffs for renewable electricity. The goal is to identify positive and negative interactions between energy efficiency and renewable electricity promotion and to assess whether the choice of specific instruments and design elements within those instruments affects the results of the interactions.

  6. Analysing the interactions between renewable energy promotion and energy efficiency support schemes. The impact of different instruments and design elements

    Energy Technology Data Exchange (ETDEWEB)

    Del Rio, Pablo [Instituto de Politicas y Bienes Publicos, Consejo Superior de Investigaciones Cientificas (CSIC), C/Albasanz 26-28, 28037 Madrid (Spain)

    2010-09-15

    CO{sub 2} emissions reduction, renewable energy deployment and energy efficiency are three main energy/environmental goals, particularly in Europe. Their relevance has led to the implementation of support schemes in these realms. Their coexistence may lead to overlaps, synergies and conflicts between them. The aim of this paper is to analyse the interactions between energy efficiency measures and renewable energy promotion, whereas previous analyses have focused on the interactions between emissions trading schemes (ETS) and energy efficiency measures and ETS and renewable energy promotion schemes. Furthermore, the analysis in this paper transcends the certificate debate (i.e., tradable green and white certificates) and considers other instruments, particularly feed-in tariffs for renewable electricity. The goal is to identify positive and negative interactions between energy efficiency and renewable electricity promotion and to assess whether the choice of specific instruments and design elements within those instruments affects the results of the interactions. (author)

  7. Effect of Instrument Design and Access Outlines on the Removal of Root Canal Obturation Materials in Oval-shaped Canals.

    Science.gov (United States)

    Niemi, Tuomas K; Marchesan, Melissa A; Lloyd, Adam; Seltzer, Robert J

    2016-10-01

    The aim of this study was to compare the effectiveness of TRUShape (TS) instruments with ProFile Vortex Blue (VB) instruments for the removal of obturation materials during retreatment of single-canal mandibular premolars performed through 2 access outlines. Initial root canal treatment was completed through a contracted endodontic cavity (CEC) design. Canals were instrumented to an F2 ProTaper instrument, obturated with warm lateral condensation of gutta-percha with AH Plus sealer, and allowed to set for 30 days at 37°C and 100% humidity. For retreatment, specimens were divided into 2 groups (n = 24) on the basis of access outline, CEC or traditional endodontic cavity (TEC). Retreatment was initiated by using ProTaper Retreatment instruments (D1-D3). Specimens were then stratified, further divided (n = 12), and reinstrumented up to TS 40 .06v or 40 .06 VB. Irrigation was performed by using 8.25% NaOCl and QMix 2in1. Retreatment time was recorded. Teeth were sectioned and photographed, and the percentage of remaining obturation materials was measured. Data were analyzed with Kruskal-Wallis analysis of variance for two-factor tests (α canal surface when compared with TEC-VB, CEC-TS, and TEC-TS (P ≤ .05). None of these other combinations were different from each other (P > .05). Significantly more time was required for retreatment with CEC-TS (27.68 ± 1.4 minutes) than the other groups (P root canal surface of mandibular premolars. However, in the presence of a CEC access design, using TS instruments removed more obturating material in single-rooted, oval-shaped canals. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Designing an Instrument to Measure the QoS of a Spanish Virtual Store

    Science.gov (United States)

    de Abajo, Beatriz Sainz; de La Torre Díez, Isabel; Salcines, Enrique García; Fernández, Javier Burón; Pernas, Francisco Díaz; Coronado, Miguel López; de Castro Lozano, Carlos

    This article describes the development of an instrument, in the form of a survey, which is distributed to users of a B2C website selling electronic books in order to ascertain their satisfaction. The opinions compiled from a pilot sample and the exploratory factor analysis carried out point to factors that best summarise the quality of the application analysed here. Analysis of the initial survey, with a total of 40 items, shaped the final instrument, encompassing 18 items divided into 6 dimensions, which measure the perceptions of users of the application in order to improve the contents of the website. Subsequently, a confirmatory factorial analysis is performed, ensuring the reliability of the study and which confirms that the structure of the instrument developed truly measures service quality in accordance with the requirements of the website in terms of offering a space that fulfils consumer expectations in the Information Society.

  9. Design of coordinated controller in nuclear power plant based on digital instrument and control technology

    International Nuclear Information System (INIS)

    Cheng Shouyu; Peng Minjun; Liu Xinkai; Zhao Qiang; Deng Xiangxin

    2014-01-01

    Nuclear power plant (NPP) is a multi-input and multi-output, no-linear and time-varying complex system. The conventional PID controller is usually used in NPP control system which is based on analog instrument. The system parameters are easy to overshoot and the response time is longer in the control mode of the conventional PID. In order to improve this condition, a new coordinated control strategy which is based on expert system and the original controllers in the digital instrument and control technology was presented. In order to verify and validate it, the proposed coordinated control technology was tested by the full-scope real-time simulation system. The results prove that using digital instrument and control technology to achieve coordinated controller is feasible, the coordinated controller can effectively improve the dynamic operating characteristics of the system, and the coordinated controller is superior to the conventional PID controller in control performance. (authors)

  10. Impact of mental health first aid training on pharmacy students' knowledge, attitudes and self-reported behaviour: a controlled trial.

    Science.gov (United States)

    O'Reilly, Claire L; Bell, J Simon; Kelly, Patrick J; Chen, Timothy F

    2011-07-01

    The aim of this study was to assess the impact of delivering Mental Health First Aid (MHFA) training for pharmacy students on their mental health literacy and stigma towards mental illness. A non-randomized controlled design was used, with all third year pharmacy students at the University of Sydney (n = 272) in 2009 invited to participate in one of two MHFA training courses, each of 12 hours duration. Of these, 174 students applied for MHFA training, of whom 60 were randomly selected and offered MHFA training. Outcome measures that were completed by all participants in the MHFA and non-MHFA groups before and after the MHFA training included an evaluation of mental health literacy, the 7-item social distance scale, and 16 items related to self-reported behaviour. The survey instrument was completed by 258 participants at baseline (59 MHFA and 199 non-MHFA) and 223 participants at follow up (53 MHFA and 170 non-MHFA). The MHFA training improved the participants' ability to correctly identify a mental illness (p = 0.004). There was a significant mean decrease in total social distance of 2.18 (SD 3.35) p training. This study demonstrated that MHFA training can reduce pharmacy students' mental health stigma, improve recognition of mental disorders and improve confidence in providing services to consumers with a mental illness in the pharmacy setting.

  11. Self reported skin morbidity and ethnicity: a population-based study in a Western community

    Directory of Open Access Journals (Sweden)

    Kumar Bernadette

    2007-06-01

    Full Text Available Abstract Background Recent studies have shown ethnic differences concerning cardio-vascular disease, diabetes and mental health. Little is known about ethnic differences in skin morbidity. The purpose of this study was to describe possible ethnic differences in self-reported skin morbidity in a Western urban community. Methods The design was cross sectional. 40 888 adults in Oslo, Norway, received a postal questionnaire providing information on socio-demographic factors and self-reported health, including items on skin complaints. Results 18770 individuals answered the questionnaire. In the sample 84% were from Norway. The largest immigrant group was from Western countries (5% and the Indian Subcontinent (3%. Itch was the most prevalent reported skin symptom (7%, and was significantly more reported by men from East Asia (18% and Middle East/North Africa (13%. The same observations were seen for reported dry and sore skin. Hair loss was a dominating complaint for men from the Indian Subcontinent and the Middle East/North Africa (23% and 25% and for women from the same ethnic groups. Women from Sub-Saharan Africa reported significantly more pimples than in the other groups (17%. Conclusion The study showed that there were significant differences in self-reported skin complaints among ethnic groups. Issues concerning the cultural value of some skin symptoms should be examined further.

  12. Job Burnout, Work Engagement and Self-reported Treatment for Health Conditions in South Africa.

    Science.gov (United States)

    de Beer, Leon T; Pienaar, Jaco; Rothmann, Sebastiaan

    2016-02-01

    The purpose of the study being reported here was to investigate the relationship of job burnout and work engagement with self-reported received treatment for health conditions (cardiovascular condition, high cholesterol, depression, diabetes, hypertension and irritable bowel syndrome), while controlling for age, gender, smoking and alcohol use. The sample comprised 7895 employees from a broad range of economic sectors in the South African working population. A cross-sectional survey design was used for the study. Structural equation modelling methods were implemented with a weighted least squares approach. The results showed that job burnout had a positive relationship with self-reported received treatment for depression, diabetes, hypertension and irritable bowel syndrome. Work engagement did not have any significant negative or positive relationships with the treatment for these health conditions. The results of this study make stakeholders aware of the relationship between job burnout, work engagement and self-reported treatment for health conditions. Evidence for increased reporting of treatment for ill-health conditions due to burnout was found. Therefore, attempts should be made to manage job burnout to prevent ill-health outcomes. Copyright © 2014 John Wiley & Sons, Ltd.

  13. Regional differences in the validity of self-reported use of health care in Belgium: selection versus reporting bias

    Directory of Open Access Journals (Sweden)

    J. Van der Heyden

    2016-08-01

    Full Text Available Abstract Background The Health Care Module of the European Health Interview Survey (EHIS is aimed to obtain comparable information on the use of inpatient and ambulatory care in all EU member states. In this study we assessed the validity of self-reported information on the use of health care, collected through this instrument, in the Belgian Health Interview Survey (BHIS, and explored the impact of selection and reporting bias on the validity of regional differences in health care use observed in the BHIS. Methods To assess reporting bias, self-reported BHIS 2008 data were linked with register-based data from the Belgian compulsory health insurance (BCHI. The latter were compared with similar estimates from a random sample of the BCHI to investigate the selection bias. Outcome indicators included the prevalence of a contact with a GP, specialist, dentist and a physiotherapist, as well as inpatient and day patient hospitalisation. The validity of the estimates and the regional differences were explored through measures of agreement and logistic regression analyses. Results Validity of self-reported health care use varies by type of health service and is more affected by reporting than by selection bias. Compared to health insurance estimates, self-reported results underestimate the percentage of people with a specialist contact in the past year (50.5 % versus 65.0 % and a day patient hospitalisation (7.8 % versus 13.9 %. Inversely, survey results overestimated the percentage of people having visited a dentist in the past year: 58.3 % versus 48.6 %. The best concordance was obtained for an inpatient hospitalisation (kappa 0.75. Survey data overestimate the higher prevalence of a contact with a specialist [OR 1.51 (95 % CI 1.33–1.72 for self-report and 1.08 (95 % CI 1.05–1.15 for register] and underestimate the lower prevalence of a contact with a GP [ORs 0.59 (95 % CI 0.51–0.70 and 0.41 (95 % CI 0.39–0.42 respectively] in

  14. Design and implementation of embedded ion mobility spectrometry instrument based on SOPC

    Science.gov (United States)

    Zhang, Genwei; Zhao, Jiang; Yang, Liu; Liu, Bo; Jiang, Yanwei; Yang, Jie

    2015-02-01

    On the hardware platform with single CYCLONE IV FPGA Chip based on SOPC technology, the control functions of IP cores of a Ion Mobility Spectrometry instrument was tested, including 32 bit Nios II soft-core processor, high-voltage module, ion gate switch, gas flow, temperature and pressure sensors, signal acquisition and communication protocol. Embedded operating system μCLinux was successfully transplanted to the hardware platform, used to schedule all the tasks, such as system initialization, parameter setting, signal processing, recognition algorithm and results display. The system was validated using the IMS diagram of Acetone reagent, and the instrument was proved to have a strong signal resolution.

  15. The Mid-Infrared Instrument for the James Webb Space Telescope, II: Design and Build

    DEFF Research Database (Denmark)

    Wright, G. S.; Wright, David; Goodson, G. B.

    2015-01-01

    The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST) provides measurements over the wavelength range 5 to 28: 5 µm. MIRI has, within a single "package," four key scientific functions: photometric imaging, coronagraphy, single-source low-spectral resolving power (R similar...... in terms of the "as-built" instrument. It also describes the test program that led to delivery of the tested and calibrated Flight Model to NASA in 2012, and the confirmation after delivery of the key interface requirements....

  16. Design and Ground Calibration of the Helioseismic and Magnetic Imager (HMI) Instrument on the Solar Dynamics Observatory (SDO)

    Science.gov (United States)

    Schou, J.; Scherrer, P. H.; Bush, R. I.; Wachter, R.; Couvidat, S.; Rabello-Soares, M. C.; Bogart, R. S.; Hoeksema, J. T.; Liu, Y.; Duvall, T. L., Jr.; hide

    2012-01-01

    The Helioseismic and Magnetic Imager (HMI) investigation will study the solar interior using helioseismic techniques as well as the magnetic field near the solar surface. The HMI instrument is part of the Solar Dynamics Observatory (SDO) that was launched on 11 February 2010. The instrument is designed to measure the Doppler shift, intensity, and vector magnetic field at the solar photosphere using the 6173 Fe I absorption line. The instrument consists of a front-window filter, a telescope, a set of wave plates for polarimetry, an image-stabilization system, a blocking filter, a five-stage Lyot filter with one tunable element, two wide-field tunable Michelson interferometers, a pair of 4096(exo 2) pixel cameras with independent shutters, and associated electronics. Each camera takes a full-disk image roughly every 3.75 seconds giving an overall cadence of 45 seconds for the Doppler, intensity, and line-of-sight magnetic-field measurements and a slower cadence for the full vector magnetic field. This article describes the design of the HMI instrument and provides an overview of the pre-launch calibration efforts. Overviews of the investigation, details of the calibrations, data handling, and the science analysis are provided in accompanying articles.

  17. Unintentional injury and its prevention in infant: knowledge and self-reported practices of main caregivers.

    Science.gov (United States)

    Ramdzan, Siti Nurkamilla; Liew, Su May; Khoo, Ee Ming

    2014-05-29

    Unintentional injuries are the major cause of morbidity and mortality in infants. Prevention of unintentional injuries has been shown to be effective with education. Understanding the level of knowledge and practices of caregivers in infant safety would be useful to identify gaps for improvement. A cross-sectional study was conducted in an urban government health clinic in Malaysia among main caregivers of infants aged 11 to 15 months. Face-to-face interviews were conducted using a semi-structured self-designed questionnaire. Responses to the items were categorised by the percentage of correct answers: poor (70%). A total of 403 caregivers participated in the study. Of the 21 items in the questionnaire on knowledge, 19 had good-to-moderate responses and two had poor responses. The two items on knowledge with poor responses were on the use of infant walkers (26.8%) and allowing infants on motorcycles as pillion riders (27.3%). Self-reported practice of infant safety was poor. None of the participants followed all 19 safety practices measured. Eight (42.1%) items on self-reported practices had poor responses. The worst three of these were on the use of baby cots (16.4%), avoiding the use of infant walkers (23.8%) and putting infants to sleep in the supine position (25.6%). Better knowledge was associated with self-reported safety practices in infants (p safety was good but self-reported practice was poor. Further research in the future is required to identify interventions that target these potentially harmful practices.

  18. Tobacco use and self-reported morbidity among rural Indian adults.

    Science.gov (United States)

    Barik, Anamitra; Rai, Rajesh Kumar; Chowdhury, Abhijit

    2016-09-01

    Aim To measure the prevalence of self-reported morbidity and its associated factors among adults (aged ⩾15 years) in a select rural Indian population. Self-reporting of smoking has been validated as population-based surveys using self-reported data provide reasonably consistent estimates of smoking prevalence, and are generally considered to be sufficiently accurate for tracking the general pattern of morbidity associated with tobacco use in populations. However, to gauge the true disease burden using self-reported morbidity data requires cautious interpretation. During 2010-2011, a cross-sectional survey was conducted under the banner of the Health and Demographic Surveillance System, Birbhum, an initiative of the Department of Health and Family Welfare, Government of West Bengal, India. With over 93.6% response rate from the population living in 12 300 households, this study uses the responses from 16 354 individuals: 8012 smokers, and 8333 smokeless tobacco users. Smokers and smokeless tobacco users were asked whether they have developed any morbidity symptoms due to smoking, or smokeless tobacco use. Bivariate, as well as multivariate logistic regression analyses were deployed to attain the study objective. Findings Over 20% of smokers and over 9% of smokeless tobacco users reported any morbidity. Odds ratio (OR) with 95% confidence interval (CI) estimated using logistic regression shows that women are less likely to report any morbidity attributable to smoking (OR: 0.69; CI: 0.54-0.87), and more likely to report any morbidity due to smokeless tobacco use (OR: 1.68; CI: 1.36-2.09). Non-Hindus have higher odds, whereas the wealthiest respondents have lower odds of reporting any morbidity. With a culturally appropriate intervention to change behaviour, youth (both men and women) could be targeted with comprehensive tobacco cessation assistance programmes. A focussed intervention could be designed for unprocessed tobacco users to curb hazardous effects of

  19. How are learning strategies reflected in the eyes? Combining results from self-reports and eye-tracking.

    Science.gov (United States)

    Catrysse, Leen; Gijbels, David; Donche, Vincent; De Maeyer, Sven; Lesterhuis, Marije; Van den Bossche, Piet

    2018-03-01

    Up until now, empirical studies in the Student Approaches to Learning field have mainly been focused on the use of self-report instruments, such as interviews and questionnaires, to uncover differences in students' general preferences towards learning strategies, but have focused less on the use of task-specific and online measures. This study aimed at extending current research on students' learning strategies by combining general and task-specific measurements of students' learning strategies using both offline and online measures. We want to clarify how students process learning contents and to what extent this is related to their self-report of learning strategies. Twenty students with different generic learning profiles (according to self-report questionnaires) read an expository text, while their eye movements were registered to answer questions on the content afterwards. Eye-tracking data were analysed with generalized linear mixed-effects models. The results indicate that students with an all-high profile, combining both deep and surface learning strategies, spend more time on rereading the text than students with an all-low profile, scoring low on both learning strategies. This study showed that we can use eye-tracking to distinguish very strategic students, characterized using cognitive processing and regulation strategies, from low strategic students, characterized by a lack of cognitive and regulation strategies. These students processed the expository text according to how they self-reported. © 2017 The British Psychological Society.

  20. Self-reported mental health and its gender differences as a predictor of suicide in the middle-aged.

    Science.gov (United States)

    Bramness, Jørgen G; Walby, Fredrik A; Hjellvik, Vidar; Selmer, Randi; Tverdal, Aage

    2010-07-15

    Studies of clinical cohorts and retrospective reports have identified psychiatric disorders as paramount risk factors for suicide. Much less is known about how self-reported mental health is related to completed suicide. To study the relation between self-reported mental health and risk of completed suicide, the authors prospectively followed a population-based Norwegian cohort of 61,588 men and 69,774 women aged 39-44 years for an average of 10.4 years between 1994 and 2007. Self-reported mental health was measured using an instrument based on the Hopkins Symptom Checklist and the General Health Questionnaire. Completed suicides were registered in the official Norwegian Cause of Death Registry. Females reported higher levels of mental distress than males. In comparison with persons reporting the fewest mental health symptoms, the adjusted hazard ratio for suicide increased from 1.8 (95% confidence interval (CI): 1.1, 2.9) in the moderately depressed group to 8.9 (95% CI: 4.4, 18.2) in the most depressed group. The risk difference was greatest in males. At each level of the mental health index, males had double the risk of suicide of females (hazard ratio = 2.3, 95% CI: 1.5, 3.3). This study shows a dose-response effect of self-reported mental health problems on completed suicide and replicates the gender paradox observed in the general population with prospective data.

  1. Associations Between the Self-Reported Frequency of Hearing Chemical Alarms in Theater and Visuospatial Function in Gulf War Veterans.

    Science.gov (United States)

    Chao, Linda L

    2016-10-01

    The aim of this study was to examine the relationship between the self-reported frequencies of hearing chemical alarms during deployment and visuospatial function in Gulf War (GW) veterans. The relationship between the self-reported frequency of hearing chemical alarms, neurobehavioral, and volumetric brain imaging data was examined with correlational, regression, and mediation analyses. The self-reported frequency of hearing chemical alarms was inversely associated with and significantly predicted performance on a visuospatial task (ie, Block Design) over and above potentially confounding variables, including concurrent, correlated GW-related exposures. This effect was partially mediated by the relationship between hearing chemical alarms and lateral occipital cortex volume. Exposure to substances that triggered chemical alarms during GW deployment likely had adverse effects on veterans' brain structure and function, warranting further investigation of whether these GW veterans are at an increased risk for dementia.

  2. Perceptions of community, social capital, and how they affect self-reported health: a multilevel analysis.

    Science.gov (United States)

    Dziadkowiec, O; Meissen, G J; Merkle, E C

    2017-11-01

    The link between social capital and self-reported health has been widely explored. On the other hand, we know less about the relationship between social capital, community socioeconomic characteristics, and non-social capital-related individual differences, and about their impact on self-reported health in community settings. Cross-sectional study design with a proportional sample of 7965 individuals from 20 US communities were analyzed using multilevel linear regression models, where individuals were nested within communities. The response rates ranged from 13.5% to 25.4%. Findings suggest that perceptions of the community and individual level socioeconomic characteristics were stronger predictors of self-reported health than were social capital or community socioeconomic characteristics. Policy initiatives aimed at increasing social capital should first assess community member's perceptions of their communities to uncover potential assets to help increase social capital. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  3. Examining Unlock Journaling with Diaries and Reminders for In Situ Self-Report in Health and Wellness.

    Science.gov (United States)

    Zhang, Xiaoyi; Pina, Laura R; Fogarty, James

    2016-05-07

    In situ self-report is widely used in human-computer interaction, ubiquitous computing, and for assessment and intervention in health and wellness. Unfortunately, it remains limited by high burdens. We examine unlock journaling as an alternative. Specifically, we build upon recent work to introduce single-slide unlock journaling gestures appropriate for health and wellness measures. We then present the first field study comparing unlock journaling with traditional diaries and notification-based reminders in self-report of health and wellness measures. We find unlock journaling is less intrusive than reminders, dramatically improves frequency of journaling, and can provide equal or better timeliness . Where appropriate to broader design needs, unlock journaling is thus an overall promising method for in situ self-report.

  4. Cold Vacuum Drying Safety Class Instrumentation and Control System Design Description SYS 93-2

    International Nuclear Information System (INIS)

    WHITEHURST, R.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) Safety Class Instrumentation and Control system (SCIC). The SCIC provides safety functions and features to protect the environment, off-site and on-site personnel and equipment. The function of the SCIC is to provide automatic trip features, valve interlocks, alarms, indication and control for the cold vacuum drying process

  5. Cold Vacuum Drying Safety Class Instrumentation and Control System Design Description

    International Nuclear Information System (INIS)

    WHITEHURST, R.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) Safety Class Instrumentation and Control system (SCIC). The SCIC provides safety functions and features to protect the environment, off-site and on-site personnel and equipment. The function of the SCIC is to provide automatic trip features, valve interlocks, alarms, indication and control for the cold vacuum drying process

  6. Development of an instrument designed to measure employees' perceptions of workplace breastfeeding support.

    Science.gov (United States)

    Greene, Sally W; Olson, Beth H

    2008-09-01

    Breastfeeding rates remain low in the United States, especially among working women. Unfortunately, no quantitative instrument exists to facilitate the examination of why women who return to work discontinue breastfeeding sooner than the general population. The objective of this study was to develop an instrument to measure female employees' perceptions of breastfeeding support in the workplace, which would be suitable for piloting with the target population. Examination of the literature, reviews with experts, and one-on-one interviews with women who had experience combining breastfeeding and work were used to create the instrument subscales and items. Examination of the literature was used to develop four subscales: company policies/work culture, manager support, co-worker support, and workflow. Expert review resulted in the addition of a fifth subscale, the physical environment of the breastfeeding space. One-on-one interviews were used to ensure that the item wording was appropriate for the target population. Eighteen items were added, and 15 were reworded based on comments from the expert review and from the interviews. The resulting survey contained 54 items that required either categorical yes/no or Likert scale responses. Results from this process indicate the survey subscales and items adequately reflect women's perceptions of breastfeeding support in the workplace and the instrument is appropriate for piloting with new mother employees.

  7. Task 5c: measurement and instrumentation under subsystem design of the LLL safeguard material control program

    International Nuclear Information System (INIS)

    1976-01-01

    A product survey was conducted of all security products currently available on the market. Documentation is presented of the survey and a printout of the data is included. A general description is given of new but recommended instrumentation and security devices for application to fuel reprocessing plants. Security systems and hardware recommended for development, assembly, and testing are discussed briefly

  8. The Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI: design, execution, and early results

    Directory of Open Access Journals (Sweden)

    A. J. M. Piters

    2012-02-01

    Full Text Available From June to July 2009 more than thirty different in-situ and remote sensing instruments from all over the world participated in the Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI. The campaign took place at KNMI's Cabauw Experimental Site for Atmospheric Research (CESAR in the Netherlands. Its main objectives were to determine the accuracy of state-of-the-art ground-based measurement techniques for the detection of atmospheric nitrogen dioxide (both in-situ and remote sensing, and to investigate their usability in satellite data validation. The expected outcomes are recommendations regarding the operation and calibration of such instruments, retrieval settings, and observation strategies for the use in ground-based networks for air quality monitoring and satellite data validation. Twenty-four optical spectrometers participated in the campaign, of which twenty-one had the capability to scan different elevation angles consecutively, the so-called Multi-axis DOAS systems, thereby collecting vertical profile information, in particular for nitrogen dioxide and aerosol. Various in-situ samplers and lidar instruments simultaneously characterized the variability of atmospheric trace gases and the physical properties of aerosol particles. A large data set of continuous measurements of these atmospheric constituents has been collected under various meteorological conditions and air pollution levels. Together with the permanent measurement capability at the CESAR site characterizing the meteorological state of the atmosphere, the CINDI campaign provided a comprehensive observational data set of atmospheric constituents in a highly polluted region of the world during summertime. First detailed comparisons performed with the CINDI data show that slant column measurements of NO2, O4 and HCHO with MAX-DOAS agree within 5 to 15%, vertical profiles of NO2 derived from several independent

  9. A desk evaluation review of project VIE/4/009 design and production of nuclear instruments. Project desk evaluation

    International Nuclear Information System (INIS)

    1994-01-01

    A Project Desk Evaluation (PDE) is an intensive review process, using agreed guidelines, of the design, implementation, and the output of a project. This project is exclusively dealing with the design and production of nuclear instruments. The aim of this project would be to develop a viable capability for maintenance and repair of the nuclear instruments at the Dalat Research Institute (DNRI), the premier nuclear centre in Viet Nam, and also to meet the steadily increasing needs of DNRI, as well as of other national institutions, hospitals and universities engaged in the application of nuclear technologies, particularly in the southern part of the country. Project Summary with financial data is given along with training programme. 1 tab

  10. A desk evaluation review of project VIE/4/009 design and production of nuclear instruments. Project desk evaluation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-09

    A Project Desk Evaluation (PDE) is an intensive review process, using agreed guidelines, of the design, implementation, and the output of a project. This project is exclusively dealing with the design and production of nuclear instruments. The aim of this project would be to develop a viable capability for maintenance and repair of the nuclear instruments at the Dalat Research Institute (DNRI), the premier nuclear centre in Viet Nam, and also to meet the steadily increasing needs of DNRI, as well as of other national institutions, hospitals and universities engaged in the application of nuclear technologies, particularly in the southern part of the country. Project Summary with financial data is given along with training programme. 1 tab.

  11. Obtaining Self-Report Data from Cognitively Impaired Elders: Methodological Issues and Clinical Implications for Nursing Home Pain Assessment

    Science.gov (United States)

    Fisher, Susan E.; Burgio, Louis D.; Thorn, Beverly E.; Hardin, J. Michael

    2006-01-01

    Purpose: We developed and evaluated an explicit procedure for obtaining self-report pain data from nursing home residents across a broad range of cognitive status, and we evaluated the consistency, stability, and concurrent validity of resident responses. Design and Methods: Using a modification of the Geriatric Pain Measure (GPM-M2), we…

  12. Self-reported health-related quality of life in kindergarten children : psychometric properties of the Kiddy-KINDL

    NARCIS (Netherlands)

    Villalonga-Olives, E.; Kiese-Himmel, C.; Witte, C.; Almansa, J.; Dusilova, I.; Hacker, K.; von Steinbuechel, N.

    Objectives: To assess the psychometric properties of the German self-reported version of the Kiddy-KINDL that measures Health Related Quality of Life (HRQoL) in 3 to 5 year old kindergarten children. Study design: The population of the study comprised baseline data of a longitudinal study whose main

  13. Content Validity of the ADHD Rating Scale (ADHD RS-IV and Adult ADHD Self-Report Scale (ASRS in Phenylketonuria

    Directory of Open Access Journals (Sweden)

    Kathleen W. Wyrwich PhD

    2016-03-01

    Full Text Available The ADHD Rating Scale (ADHD RS-IV; parent report and Adult ADHD Self-Rating Scale (ASRS; self-report are validated instruments for measuring symptoms of attention-deficit/hyperactivity disorder (ADHD. The objectives of this study were to elicit descriptions of phenylketonuria (PKU symptoms and assess content validity of these instruments in PKU. Parents (N = 15 of children with PKU (≥8 years old and adults with PKU (N=13 described PKU-related symptoms and commented on the scale’s clarity, comprehensiveness, and relevance to their experience with PKU. Most of the adults (84.6% and all of the children were on a phenylalanine-restricted diet, according to respondent report. The inattentiveness symptoms reported by participants mapped to the inattentive items of the questionnaires. Most participants felt the inattentive items were clear and relevant to their experience. Despite study design limitations, these results demonstrate the relevance of assessing inattentiveness in PKU, and both instruments achieved content validity for inattentive subscale items.

  14. A case study on the design of a modular surgical instrument for removing metastases using engineering design tools

    OpenAIRE

    Preca, George; Farrugia, Philip; Casha, Aaron; International Conference on Engineering and Product Design Education

    2014-01-01

    Metastatic cancer is a form of cancer stemming from a primary tumour that propagates to different organs and/or to different sites within the same organ. Studies have indicated that the chances of survival improve upon surgical removal of metastases. The overall goal of this research was to develop a modular surgical instrument that would be easy to use and manipulate and hence facilitate resection of metastases. This research forms part of a final year project carried out by a mechanical eng...

  15. Self-reported bruxism mirrors anxiety and stress in adults.

    Science.gov (United States)

    Ahlberg, Jari; Lobbezoo, Frank; Ahlberg, Kristiina; Manfredini, Daniele; Hublin, Christer; Sinisalo, Juha; Könönen, Mauno; Savolainen, Aslak

    2013-01-01

    The aims were to analyze whether the levels of self-reported bruxism and anxiety associate among otherwise healthy subjects, and to investigate the independent effects of anxiety and stress experience on the probability of self-reported bruxism. As part of a study on irregular shift work, a questionnaire was mailed to all employees of the Finnish Broadcasting Company with irregular shift work (number of subjects: n=750) and to an equal number of randomly selected employees in the same company with regular eight-hour daytime work. The response rates were 82.3% (56.6 % men) and 34.3 % (46.7 % men), respectively. Among the 874 respondents, those aware of more frequent bruxism reported significantly more severe anxiety (pbruxism and psychological states such as anxiety or stress may be related in working age subjects.

  16. Self-reported delinquency in a probation service in Brazil

    Directory of Open Access Journals (Sweden)

    Lylla Cysne Frota D'Abreu

    2012-02-01

    Full Text Available International research shows that self-reported delinquency is a successful strategy to improve data collection on the identification of the so-called "dark figure", ie, offenses that are not reported to the justice system. This technique, however, is still little used in Brazil. Through documentary research from data archive, this study described the socio-demographic variables and the severity of unofficial delinquency of a sample of 211 adolescents who attended a probation service in Brazil. The results showed that adolescents in conflict with the law have delinquent engagement with higher polymorphism and intensity than the official data are able to identify. Self-reported delinquency can improve data collection, provide more reliable rates and guide more assertive intervention actions in these services.

  17. The design and q resolution of the small and wide angle neutron scattering instrument (TAIKAN) in J-PARC

    International Nuclear Information System (INIS)

    Takata, Shin-ichi; Suzuki, Jun-ichi; Shinohara, Takenao; Oku, Takayuki; Tominaga, Taiki; Nakatani, Takeshi; Inamura, Yasuhiro; Suzuya, Kentaro; Aizawa, Kazuya; Arai, Masatoshi; Ohishi, Kazuki; Iwase, Hiroki; Ito, Takayoshi; Otomo, Toshiya; Sugiyama, Masaaki

    2015-01-01

    The small and wide angle neutron scattering instrument (TAIKAN) is designed to cover the wide q range of 0.005 0.3 Å"-"1 with the other banks. The q resolution was compared with the values experimentally obtained from the widths of Bragg peaks of a standard sample, silver behenate. The results of the experiment were consistent with the theory. It was confirmed that TAIKAN was completed as was expected. (author)

  18. SKALA, a log-periodic array antenna for the SKA-low instrument: design, simulations, tests and system considerations

    Science.gov (United States)

    de Lera Acedo, E.; Razavi-Ghods, N.; Troop, N.; Drought, N.; Faulkner, A. J.

    2015-10-01

    The very demanding requirements of the SKA-low instrument call for a challenging antenna design capable of delivering excellent performance in radiation patterns, impedance matching, polarization purity, cost, longevity, etc. This paper is devoted to the development (design and test of the first prototypes) of an active ultra-wideband antenna element for the low-frequency instrument of the SKA radio telescope. The antenna element and differential low noise amplifier described here were originally designed to cover the former SKA-low band (70-450 MHz) but it is now aimed to cover the re-defined SKA-low band (50-350 MHz) and furthermore the antenna is capable of performing up to 650 MHz with the current design. The design is focused on maximum sensitivity in a wide field of view (+/- 45° from zenith) and low cross-polarization ratios. Furthermore, the size and cost of the element has to be kept to a minimum as millions of these antennas will need to be deployed for the full SKA in very compact configurations. The primary focus of this paper is therefore to discuss various design implications for the SKA-low telescope.

  19. Self-reported inhibition predicts history of suicide attempts in bipolar disorder and major depression.

    Science.gov (United States)

    Ponsoni, André; Branco, Laura Damiani; Cotrena, Charles; Shansis, Flávio Milman; Grassi-Oliveira, Rodrigo; Fonseca, Rochele Paz

    2018-04-01

    Studies have reliably identified an association between suicide attempts and executive functions such as decision making (DM) and inhibitory control (IC) in patients with mood disorders. As such, the present study aimed to investigate the association between inhibition, DM, impulsivity and the history of suicide attempts in individuals with bipolar (BD) or major depressive disorder (MDD), identifying which assessment instruments may be most strongly associated with suicide in clinical samples. The sample included 80 control subjects and two groups of patients with BD and MDD, matched by age and education (26 with a history of suicide attempts [MD+], and 26 with no such history [MD-]). Participants completed behavioral and self-report measures of DM and IC, which were compared between groups using ANCOVA, followed by logistic regression for patients with mood disorders only, and the presence or absence of a history of suicide as the outcome. Cognitive performance did not differ between groups. The MD+ group showed significantly higher motor and attentional impulsivity on the BIS-11 than the MD- and control groups. A regression analysis containing these scores showed that motor impulsivity was the only significant predictor of a history of suicide (OR = 1.14; 95%CI 1.00-1.30). Self-reported motor impulsivity was a significant predictor of suicide. These findings underscore the importance of self-report measures in neuropsychological assessment, and their contributions to the management and prognosis of patients with mood disorders. Lastly, they point to the role of impulsivity as a target for interventions and public policy on suicide prevention. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Prevalence and causes of self-reported work-related stress in head teachers.

    Science.gov (United States)

    Phillips, Samantha; Sen, Dil; McNamee, Roseanne

    2007-08-01

    Work-related stress (WRS) is the leading cause of occupational ill-health in the education sector in the UK. Headship is believed to be a stressful role although there is little current research into stress in head teachers. Changes in the education sector since the late 1980s have meant that the findings of many existing studies are outdated. To investigate prevalence and causes of self-reported, WRS in head teachers in West Sussex, UK. A cross-sectional study using postal questionnaire in a population of 290 head teachers and principals. The measuring instrument was a short stress evaluation tool (ASSET) plus additional questions derived from previous studies. Stress cases were defined as respondents who felt their work was 'very or extremely stressful'. Prevalence of self-reported, WRS was 43%. Using ASSET scoring, work overload and work-life imbalance were the key stressors. Females were significantly more stressed than males for a number of stressors including overload and control. Although there was some evidence that primary head teachers fared worse than their secondary counterparts, once the confounding effects of gender were included, there were few significant differences. The prevalence of self-reported stress in head teachers in West Sussex is significantly increased compared to recent studies of workers in the UK. The recurring theme in existing studies of workload as a main stressor is confirmed in the findings of this study. Gender and type of school does affect outcome and female head teachers have more reported stressors than their male colleagues.

  1. Self-Reported Stroke Risk Stratification: Reasons for Geographic and Racial Differences in Stroke Study.

    Science.gov (United States)

    Howard, George; McClure, Leslie A; Moy, Claudia S; Howard, Virginia J; Judd, Suzanne E; Yuan, Ya; Long, D Leann; Muntner, Paul; Safford, Monika M; Kleindorfer, Dawn O

    2017-07-01

    The standard for stroke risk stratification is the Framingham Stroke Risk Function (FSRF), an equation requiring an examination for blood pressure assessment, venipuncture for glucose assessment, and ECG to determine atrial fibrillation and heart disease. We assess a self-reported stroke risk function (SRSRF) to stratify stroke risk in comparison to the FSRF. Participants from the REGARDS study (Reasons for Geographic and Racial Differences in Stroke) were evaluated at baseline and followed for incident stroke. The FSRF was calculated using directly assessed stroke risk factors. The SRSRF was calculated from 13 self-reported questions to exclude those with prevalent stroke and assess stroke risk. Proportional hazards analysis was used to assess incident stroke risk using the FSRF and SRSRF. Over an average 8.2-year follow-up, 939 of 23 983 participants had a stroke. The FSRF and SRSRF produced highly correlated risk scores ( r Spearman =0.852; 95% confidence interval, 0.849-0.856); however, the SRSRF had higher discrimination of stroke risk than the FSRF (c SRSRF =0.7266; 95% confidence interval, 0.7076-0.7457; c FSRF =0.7075; 95% confidence interval, 0.6877-0.7273; P =0.0038). The 10-year stroke risk in the highest decile of predicted risk was 11.1% for the FSRF and 13.4% for the SRSRF. A simple self-reported questionnaire can be used to identify those at high risk for stroke better than the gold standard FSRF. This instrument can be used clinically to easily identify individuals at high risk for stroke and also scientifically to identify a subpopulation enriched for stroke risk. © 2017 American Heart Association, Inc.

  2. Self-Reported bruxism and associated factors in Israeli adolescents.

    Science.gov (United States)

    Emodi Perlman, A; Lobbezoo, F; Zar, A; Friedman Rubin, P; van Selms, M K A; Winocur, E

    2016-06-01

    Little is known about the epidemiological characteristics of sleep and awake bruxism (SB and AB) in adolescents. The aims of the study were: to assess the prevalence rates of self-reported SB and AB in Israeli adolescents; to determine the associations between SB/AB and several demographical, exogenous and psychosocial factors in Israeli adolescents; and to investigate the possible concordance between SB and AB. The study made use of a questionnaire. The study population included 1000 students from different high schools in the centre of Israel. Prevalence of self-reported SB and AB in the Israeli adolescents studied was 9·2% and 19·2%, respectively. No gender difference was found regarding the prevalence of SB and AB. Multiple variable regression analysis revealed that the following predicting variables were related to SB: temporomandibular joint sounds (P = 0·002) and feeling stressed (P = 0·001). The following predicting variables were related to AB: age (P = 0·018), temporomandibular joint sounds (P = 0·002), oro-facial pain (P = 0·006), and feeling stressed (P = 0·002) or sad (P = 0·006). A significant association was found between SB and AB; that is, an individual reporting SB had a higher probability of reporting AB compared with an individual who did not report SB (odds ratio = 5·099). Chewing gum was the most common parafunction reported by adolescents. The results of this study demonstrate that self-reports of AB and SB are common in the Israeli adolescents population studied and are not related to gender. The significant correlation found between SB and AB may be a confounding bias that affects proper diagnosis of bruxism through self-reported questionnaires only. © 2016 John Wiley & Sons Ltd.

  3. Design and Measurement of a 2.45 Ghz On-Body Antenna Optimized for Hearing Instrument Applications

    DEFF Research Database (Denmark)

    Kvist, Søren Helstrup; Jakobsen, Kaj Bjarne; Thaysen, Jesper

    2012-01-01

    A balanced PIFA-inspired antenna design is presented for use with the 2:45 GHz ear-to-ear radio channel. The antenna is designed such that the radiated electric fields are primarily polarized normal to the surface of the head, in order to obtain a high on-body path gain (jS21 j). The antenna...... structure can be made conformal to the outer surface of a hearing instrument, such that the bandwidth of the antenna is optimized given the available volume. The radiation patterns, ear-to-ear path gain and available bandwidth is measured and compared to the simulated results. It is found that the antenna...

  4. Design and use of concrete pads for the calibration of radiometric survey instrumentation

    International Nuclear Information System (INIS)

    Loevborg, L.

    1984-10-01

    A gamma-ray spectrometer for use in geological exploration possesses four stripping ratios and three window sensitivities which must be determined to make the instrumentation applicable for field assay or airborne measurement of potassium, uranium, and thorium contents in the ground. Survey organizations in many parts of the world perform the instrument calibration using large pads of concrete which simulate a plane ground of known radioelement concentration. Calibration and monitoring trials with twelve facilities in ten countries prove that moisture absorption, radon exhalation, and particle-size effects can offset a radiometric grade assigned to concrete whose aggregate contains an embedded radioactive mineral. These and other calibration problems are discussed from a combined theoretical and practical viewpoint

  5. Design and development of control instrumentation for the superconducting Linear Accelerator

    International Nuclear Information System (INIS)

    Joshi, Gopal; Kapatral, R.S.; Jha, K.; Rathod, N.C.; Sujo, C.I.; Ananthakrishnan, T.S.; Narsaiah, A.; Ghodgaonkar, M.D.; Kataria, S.K.; Singh, S.K.

    2001-01-01

    Electronics Division, BARC is developing the required control instrumentation for the Linear Accelerator (LINAC) coming up at TIFR. This consists of RF systems, CAMAC instruments and the Control and Information System. The control system consists of several identical Local Control Stations (LCS) connected over a LAN to a Main Control Station (MCS). Each LCS consists of a PC, CAMAC crates with functional Modules and RF systems. The MCS will contain two PCs running identical software. Each LCS will cater to two LINAC module each consisting of one cryostat and four resonators. This paper discusses different systems developed and under development in the Electronics Division which play an important role in the control of the LINAC. (author)

  6. Economic instruments and clean water: Why institutions and policy design matter

    DEFF Research Database (Denmark)

    Andersen, Mikael Skou

    1994-01-01

    Since market-like policy instruments are usually applied within existing rules, institutions, and policy processes, the policy and administrative contexts in which they operate become important. These contexts are quite different from country to country, often more so than policymakers are aware ....... The national style of policymaking depends on the constitutional framework, the infrastructure of public authorities as well as the historical and cultural heritage, which are basic institutional premises that vary tremendously even between neighbouring western european countries....

  7. Economic instruments and clean water: Why institutions and policy design matter

    DEFF Research Database (Denmark)

    Andersen, Mikael Skou

    2001-01-01

    Since market-like policy instruments are usually applied within existing rules, institutions, and policy processes, the policy and administrative contexts in which they operate become important. These contexts are quite different from country to country, often more so than policymakers are aware ....... The national style of policymaking depends on the constitutional framework, the infrastructure of public authorities as well as the historical and cultural heritage, which are basic institutional premises that vary tremendously even between neighbouring western european countries....

  8. Performance Evaluation Factors: Designing an Instrument for National Health Network in Iran

    Directory of Open Access Journals (Sweden)

    Sassan Ghorbani-Kalkhajeh

    2016-04-01

    Full Text Available As a systematic process for gathering and analyzing data, performance evaluation could be used as a valid method to highlight levels of success and to identify strength and weakness of ongoing programs. The aim of the present study was to develop an instrument for evaluating rural health centers in Iran. Based on related literature and experts’ views, eight crucial fields of performance evaluation, and a questionnaire including 100 items were formed. The participants of the study were 525 people having health related jobs in rural or urban health centers. Reliability and validity requirements were checked; exploratory and confirmatory factor analyses were used. Factor analysis identified 11 components which embraced 60 items. Components were named as planning, control, coordination, structure, setting and facilities, education, customers’ satisfaction, staff’s job satisfaction, disease surveillance, mother-child care, and effectiveness which are presented as a model for performance evaluation. The obtained instrument embraces all required factors suggested by experts and literature hence it can be used as an evaluation instrument in both rural and urban health centers.

  9. Individual differences in the rubber-hand illusion: predicting self-reports of people's personal experiences.

    Science.gov (United States)

    Haans, Antal; Kaiser, Florian G; Bouwhuis, Don G; Ijsselsteijn, Wijnand A

    2012-10-01

    Can we assess individual differences in the extent to which a person perceives the rubber-hand illusion on the basis of self-reported experiences? In this research, we develop such an instrument using Rasch-type models. In our conception, incorporating an object (e.g., a rubber hand) into one's body image requires various sensorimotor and cognitive processes. The extent to which people can meet these requirements thus determines how intensely people experience and, simultaneously, describe the illusion. As a consequence, individual differences in people's susceptibility to the rubber-hand illusion can be determined by inspecting reports of their personal experiences. The proposed model turned out to be functional in its capability to predict self-reports of people's experiences and to reliably assess individual differences in susceptibility to the illusion. Regarding validity, we found a small, but significant, correlation between individual susceptibility and proprioceptive drift. Additionally, we found that asynchrony, and tapping rather than stroking the fingers constrain the experience of the illusion. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Relapse Risk Assessment for Schizophrenia Patients (RASP): A New Self-Report Screening Tool.

    Science.gov (United States)

    Velligan, Dawn; Carpenter, William; Waters, Heidi C; Gerlanc, Nicole M; Legacy, Susan N; Ruetsch, Charles

    2018-01-01

    The Relapse Assessment for Schizophrenia Patients (RASP) was developed as a six-question self-report screener that measures indicators of Increased Anxiety and Social Isolation to assess patient stability and predict imminent relapse. This paper describes the development and psychometric characteristics of the RASP. The RASP and Positive and Negative Syndrome Scale (PANSS) were administered to patients with schizophrenia (n=166) three separate times. Chart data were collected on a subsample of patients (n=81). Psychometric analyses of RASP included tests of reliability, construct validity, and concurrent validity of items. Factors from RASP were correlated with subscales from PANSS (sensitivity to change and criterion validity [agreement between RASP and evidence of relapse]). Test-retest reliability returned modest to strong agreement at the item level and strong agreement at the questionnaire level. RASP showed good item response curves and internal consistency for the total instrument and within each of the two subscales (Increased Anxiety and Social Isolation). RASP Total Score and subscales showed good concurrent validity when correlated with PANSS Total Score, Positive, Excitement, and Anxiety subscales. RASP correctly predicted relapse in 67% of cases, with good specificity and negative predictive power and acceptable positive predictive power and sensitivity. The reliability and validity data presented support the use of RASP in settings where addition of a brief self-report assessment of relapse risk among patients with schizophrenia may be of benefit. Ease of use and scoring, and the ability to administer without clinical supervision allows for routine administration and assessment of relapse risk.

  11. The SPOT-HRV instrument - An overview of design and performance

    Science.gov (United States)

    Midan, J. P.

    1983-10-01

    The SPOT spacecraft's High Visible Resolution (HVR) earth resources sensor performance requirements, system and subsystem design features, and technology development considerations, are discussed. Attention is given to such problem areas involving extensive design tradeoff analyses and testing as those uncovered by mechanical design and thermal distortion studies and SNR analysis and calibration considerations. The SPOT spacecraft will be placed in orbit in 1985.

  12. Design and Testing of a Controller for the Martian Atmosphere Pressure and Humidity Instrument DREAMS-P/H

    Science.gov (United States)

    Tapani Nikkanen, Timo; Schmidt, Walter; Genzer, Maria; Harri, Ari-Matti; Haukka, Harri

    2013-04-01

    The European Space Agency (ESA), driven by the goal of performing a soft landing on Mars, is planning to launch the Entry, descent and landing Demonstrator Module (EDM)[1] simultaneously with the Trace Gas Orbiter (TGO) as a part of the ExoMars program towards Mars in 2016. As a secondary objective, the EDM will gather meteorological data and observe the electrical environment of the landing site with its Dust characterisation, Risk assessment, and Environmental Analyser on the Martian Surface (DREAMS). The Finnish Meteorological Institute (FMI) is participating in the project by designing, building and testing a pressure and a humidity instrument for Mars, named DREAMS-P and DREAMS-H, respectively. The instruments are based on previous FMI designs, including ones flown on board the Huygens, Phoenix and Mars Science Laboratory.[2] Traditionally, the FMI pressure and humidity instruments have been controlled by an FPGA. However, the need to incorporate more autonomy and modifiability into instruments, cut the development time and component costs, stimulated interest to study a Commercial Off-The-Shelf (COTS) Microcontroller Unit (MCU) based instrument design. Thus, in the DREAMS-P/H design, an automotive MCU is used as the instrument controller. The MCU has been qualified for space by tests in and outside FMI. The DREAMS-P/H controller command and data interface utilizes a RS-422 connection to receive telecommands from and to transmit data to the Central Electronics Unit (CEU) of the DREAMS science package. The two pressure transducers of DREAMS-P and one humidity transducer of DREAMS-H are controlled by a single MCU. The MCU controls the power flow for each transducer and performs pulse counting measurements on sensor and reference channels to retrieve scientific data. Pressure and humidity measurements are scheduled and set up according to a configuration table assigned to each transducer. The configuration tables can be modified during the flight. The whole

  13. Design automation of switching mode high voltage power supply for nuclear instruments

    International Nuclear Information System (INIS)

    El-araby, S.M.S.

    1999-01-01

    This paper presents an automation procedure for the design of switching mode high voltage power supplies, using Pc programming facility. The procedure permits the selection of a ready made or designed ferrite transformer. This selection could be achieved according to the designer desire; as the program includes complete information about ready made ferrite transformer through complete database. The procedure is based on suggested template circuit. Micro-Cap IV simulation package is used to verify the desired high voltage power supply design. Simulation results agree quite well with suggested procedure's results. Design aspects and development needed to increase automation capabilities are also discussed

  14. Design of capability measurement instruments pedagogic content knowledge (PCK) for prospective mathematics teachers

    Science.gov (United States)

    Aminah, N.; Wahyuni, I.

    2018-05-01

    The purpose of this study is to find out how the process of designing a tool of measurement Pedagogical Content Knowledge (PCK) capabilities, especially for prospective mathematics teachers are valid and practical. The design study of this measurement appliance uses modified Plomp development step, which consists of (1) initial assessment stage, (2) design stage at this stage, the researcher designs the measuring grille of PCK capability, (3) realization stage that is making measurement tool ability of PCK, (4) test phase, evaluation, and revision that is testing validation of measurement tools conducted by experts. Based on the results obtained that the design of PCK capability measurement tool is valid as indicated by the assessment of expert validator, and the design of PCK capability measurement tool, shown based on the assessment of teachers and lecturers as users of states strongly agree the design of PCK measurement tools can be used.

  15. Measuring Patient Adherence to Malaria Treatment: A Comparison of Results from Self-Report and a Customised Electronic Monitoring Device.

    Science.gov (United States)

    Bruxvoort, Katia; Festo, Charles; Cairns, Matthew; Kalolella, Admirabilis; Mayaya, Frank; Kachur, S Patrick; Schellenberg, David; Goodman, Catherine

    2015-01-01

    Self-report is the most common and feasible method for assessing patient adherence to medication, but can be prone to recall bias and social desirability bias. Most studies assessing adherence to artemisinin-based combination therapies (ACTs) have relied on self-report. In this study, we use a novel customised electronic monitoring device--termed smart blister packs--to examine the validity of self-reported adherence to artemether-lumefantrine (AL) in southern Tanzania. Smart blister packs were designed to look identical to locally available AL blister packs and to record the date and time each tablet was removed from packaging. Patients obtaining AL at randomly selected health facilities and drug stores were followed up at home three days later and interviewed about each dose of AL taken. Blister packs were requested for pill count and extraction of smart blister pack data. Data on adherence from both self-report verified by pill count and smart blister packs were available for 696 of 1,204 patients. There was no difference between methods in the proportion of patients assessed to have completed treatment (64% and 67%, respectively). However, the percentage taking the correct number of pills for each dose at the correct times (timely completion) was higher by self-report than smart blister packs (37% vs. 24%; psmart blister packs, 64% of patients completing treatment did not take the correct number of pills per dose or did not take each dose at the correct time interval. Smart blister packs resulted in lower estimates of timely completion of AL and may be less prone to recall and social desirability bias. They may be useful when data on patterns of adherence are desirable to evaluate treatment outcomes. Improved methods of collecting self-reported data are needed to minimise bias and maximise comparability between studies.

  16. Impaired Prefrontal-Amygdala Pathway, Self-Reported Emotion, and Erection in Psychogenic Erectile Dysfunction Patients With Normal Nocturnal Erection

    Directory of Open Access Journals (Sweden)

    Jianhuai Chen

    2018-04-01

    Full Text Available Background: Neuroimaging studies have demonstrated that the prefrontal cortex and amygdala play an important role in sexual arousal (SA. However, little is known about the interactions between the prefrontal and cortex amygdala, which mediate the cognitive regulation of emotion and SA.Objective: We seek to determine whether nocturnal erection of psychogenic erectile dysfunction (pED patients are normal and whether there are changes of topological organization in the prefrontal-amygdala pathway of brain network in pED. In addition, whether there are correlations between network property changes and self-reported emotion and erection.Design, setting, and participants: We used the RigiScan device to evaluate erectile function of patients and employed diffusion MRI and graph theory to construct brain networks of 21 pED patients and 24 healthy controls.Outcome measurements and statistical analysis: We considered four nodal metrics and their asymmetry scores, and nocturnal penile tumescence (NPT parameters, to evaluate the topological properties of brain networks of pED and their relationships with the impaired self-reported emotion and erection.Results and limitations: All the pED patients showed normal nocturnal penile erection, however impaired self-reported erection and negative emotion. In addition, patients showed lower connectivity degree and strength in the left prefrontal-amygdala pathway. We also found that pED exhibited lower leftward asymmetry in the inferior frontal gyrus. Furthermore, patients showed more hub regions and fewer pivotal connections. Moreover, the degree of the left amygdala of pED showed significantly negative correlation with the self-reported erection and positive correlation with the self-reported negative emotion.Conclusions: Together, these results suggest normal nocturnal erection in pED. However, abnormalities of brain network organization in pED, particularly in the left prefrontal-amygdala pathway, are associated

  17. Measuring Patient Adherence to Malaria Treatment: A Comparison of Results from Self-Report and a Customised Electronic Monitoring Device.

    Directory of Open Access Journals (Sweden)

    Katia Bruxvoort

    Full Text Available Self-report is the most common and feasible method for assessing patient adherence to medication, but can be prone to recall bias and social desirability bias. Most studies assessing adherence to artemisinin-based combination therapies (ACTs have relied on self-report. In this study, we use a novel customised electronic monitoring device--termed smart blister packs--to examine the validity of self-reported adherence to artemether-lumefantrine (AL in southern Tanzania.Smart blister packs were designed to look identical to locally available AL blister packs and to record the date and time each tablet was removed from packaging. Patients obtaining AL at randomly selected health facilities and drug stores were followed up at home three days later and interviewed about each dose of AL taken. Blister packs were requested for pill count and extraction of smart blister pack data.Data on adherence from both self-report verified by pill count and smart blister packs were available for 696 of 1,204 patients. There was no difference between methods in the proportion of patients assessed to have completed treatment (64% and 67%, respectively. However, the percentage taking the correct number of pills for each dose at the correct times (timely completion was higher by self-report than smart blister packs (37% vs. 24%; p<0.0001. By smart blister packs, 64% of patients completing treatment did not take the correct number of pills per dose or did not take each dose at the correct time interval.Smart blister packs resulted in lower estimates of timely completion of AL and may be less prone to recall and social desirability bias. They may be useful when data on patterns of adherence are desirable to evaluate treatment outcomes. Improved methods of collecting self-reported data are needed to minimise bias and maximise comparability between studies.

  18. Impaired Prefrontal-Amygdala Pathway, Self-Reported Emotion, and Erection in Psychogenic Erectile Dysfunction Patients With Normal Nocturnal Erection

    Science.gov (United States)

    Chen, Jianhuai; Chen, Yun; Gao, Qingqiang; Chen, Guotao; Dai, Yutian; Yao, Zhijian; Lu, Qing

    2018-01-01

    Background: Neuroimaging studies have demonstrated that the prefrontal cortex and amygdala play an important role in sexual arousal (SA). However, little is known about the interactions between the prefrontal and cortex amygdala, which mediate the cognitive regulation of emotion and SA. Objective: We seek to determine whether nocturnal erection of psychogenic erectile dysfunction (pED) patients are normal and whether there are changes of topological organization in the prefrontal-amygdala pathway of brain network in pED. In addition, whether there are correlations between network property changes and self-reported emotion and erection. Design, setting, and participants: We used the RigiScan device to evaluate erectile function of patients and employed diffusion MRI and graph theory to construct brain networks of 21 pED patients and 24 healthy controls. Outcome measurements and statistical analysis: We considered four nodal metrics and their asymmetry scores, and nocturnal penile tumescence (NPT) parameters, to evaluate the topological properties of brain networks of pED and their relationships with the impaired self-reported emotion and erection. Results and limitations: All the pED patients showed normal nocturnal penile erection, however impaired self-reported erection and negative emotion. In addition, patients showed lower connectivity degree and strength in the left prefrontal-amygdala pathway. We also found that pED exhibited lower leftward asymmetry in the inferior frontal gyrus. Furthermore, patients showed more hub regions and fewer pivotal connections. Moreover, the degree of the left amygdala of pED showed significantly negative correlation with the self-reported erection and positive correlation with the self-reported negative emotion. Conclusions: Together, these results suggest normal nocturnal erection in pED. However, abnormalities of brain network organization in pED, particularly in the left prefrontal-amygdala pathway, are associated with the

  19. Design of a TOF-SANS instrument for the proposed long wavelength target station at the spallation neutron source

    International Nuclear Information System (INIS)

    Thiyagarajan, P.; Littrell, K.; Seeger, P.A.

    2001-01-01

    We have designed a versatile high-throughput SANS instrument [Broad Range Intense Multipurpose SANS (BRIMS)] for the proposed Long Wavelength Target Station at the SNS by using acceptance diagrams and the Los Alamos NISP Monte Carlo simulation package. This instrument has been fully optimized to take advantage of the 10 Hz source frequency (broad wavelength bandwidth) and the cold neutron spectrum from a tall coupled solid methane moderator (12 cm x 20 cm). BRIMS has been designed to produce data in a Q range spanning from 0.0025 to 0.7 A -1 in a single measurement by simultaneously using neutrons with wavelengths ranging from 1 to 14.5 A in a time of flight mode. A supermirror guide and bender assembly is employed to separate and redirect the useful portion of the neutron spectrum with λ>1 A, by 2.3deg away from the direct beam containing high energy neutrons and γ rays. The effects of various collimation choices on count rate, resolution and Q min have been characterized using spherical particle and delta function scatterers. The overall performance of BRIMS has been compared with that of the best existing reactor-based SANS instrument D22 at ILL. (author)

  20. Optomechanical Design of a Hard X-ray Nanoprobe Instrument with Nanometer-Scale Active Vibration Control

    International Nuclear Information System (INIS)

    Shu, D.; Preissner, C.; Smolyanitskiy, A.; Maser, J.; Winarski, R.; Holt, M.; Lai, B.; Vogt, S.; Stephenson, G. B.

    2007-01-01

    We are developing a new hard x-ray nanoprobe instrument that is one of the centerpieces of the characterization facilities of the Center for Nanoscale Materials being constructed at Argonne National Laboratory. This new probe will cover an energy range of 3-30 keV with 30-nm spacial resolution. The system is designed to accommodate x-ray optics with a resolution limit of 10 nm, therefore, it requires staging of x-ray optics and specimens with a mechanical repeatability of better than 5 nm. Fast feedback for differential vibration control between the zone-plate x-ray optics and the sample holder has been implemented in the design using a digital-signal-processor-based real-time closed-loop feedback technique. A specially designed, custom-built laser Doppler displacement meter system provides two-dimensional differential displacement measurements with subnanometer resolution between the zone-plate x-ray optics and the sample holder. The optomechanical design of the instrument positioning stage system with nanometer-scale active vibration control is presented in this paper

  1. Optomechanical design of a hard x-ray nanoprobe instrument with active vibration control in nanometer scale

    International Nuclear Information System (INIS)

    Shu, D.; Maser, J.; Holt, M.; Winarski, R.; Preissner, C.; Smolyanitskiy, A.; Lai, B.; Vogt, S.; Stephenson, G.

    2007-01-01

    We are developing a new hard x-ray nanoprobe instrument that is one of the centerpieces of the characterization facilities of the Center for Nanoscale Materials being constructed at Argonne National Laboratory. This new probe will cover an energy range of 3-30 keV with 30-nm spatial resolution. The system is designed to accommodate x-ray optics with a resolution limit of 10 nm, therefore, it requires staging of x-ray optics and specimens with a mechanical repeatability of better than 5 nm. Fast feedback for differential vibration control between the zone-plate x-ray optics and the sample holder has been implemented in the design using a digital-signal-processor-based real-time closed-loop feedback technique. A specially designed, custom-built laser Doppler displacement meter system provides two-dimensional differential displacement measurements with subnanometer resolution between the zone-plate x-ray optics and the sample holder. The optomechanical design of the instrument positioning stage system with nanometer-scale active vibration control is presented in this paper.

  2. Structured interview versus self-report test vantages for the assessment of personality pathology in cocaine dependence.

    Science.gov (United States)

    Marlowe, D B; Husband, S D; Bonieskie, L M; Kirby, K C; Platt, J J

    1997-01-01

    The study compared structured interview (SCID-II) and self-report test (MCMI-II) vantages for the detection and characterization of personality pathology among 144 urban, poor, cocaine-addicted individuals seeking outpatient treatment. Diagnostic agreement was inadequate for most disorders, and the instruments at best shared only modest common variance. Positive predictive power was poor for all MCMI-II scales, though negative predictive power was good to excellent. This lends support for the use of the MCMI-II as a screening measure to rule out Axis II disorders; however, confirmation of positive diagnoses will require follow-up interview assessment. Future development of self-report personality inventories for substance abusers should focus on controlling for the acute dysphoric effects of drug use and related dysfunction, expanding attention to Cluster B content domains, and incorporating more objective criteria for assessing paranoia and "odd/eccentric" traits.

  3. Self-reported urinary incontinence in elderly and its associated factors

    Directory of Open Access Journals (Sweden)

    Alisson Fernandes Bolina

    2013-05-01

    Full Text Available Household survey, cross-sectional and observational study that aimed to verify the socio-demographic factors and self-reported morbidities associated with urinary incontinence (UI. The research was carried out between August and December 2008 with 2,142 elderly people. We used a semi-structured instrument, and performed a descriptive analysis and logistic regression (p<0.05. Most were female and with income of up to one minimum wage. UI prevailed among those aged 70├80 years, widowed and uneducated; for the group without UI: 60├70 years, married or living with partner and 4├8 years of study. The factors associated with increased chances of presenting UI were: 70├80 years and 80 years and older, no education and obesity. It is important to pay attention to the factors associated with UI in the development of effective actions on health prevention.

  4. Self-reported cognitive inconsistency in older adults.

    Science.gov (United States)

    Vanderhill, Susan; Hultsch, David F; Hunter, Michael A; Strauss, Esther

    2010-01-01

    Insight into one's own cognitive abilities, or metacognition, has been widely studied in developmental psychology. Relevance to the clinician is high, as memory complaints in older adults show an association with impending dementia, even after controlling for likely confounds. Another candidate marker of impending dementia under study is inconsistency in cognitive performance over short time intervals. Although there has been a recent proliferation of studies of cognitive inconsistency in older adults, to date, no one has examined adults' self-perceptions of cognitive inconsistency. Ninety-four community-dwelling older adults (aged 70-91) were randomly selected from a parent longitudinal study of short-term inconsistency and long-term cognitive change in aging. Participants completed a novel 40-item self-report measure of everyday cognitive inconsistency, including parallel scales indexing perceived inconsistency 5 years ago and at present, yielding measures of past, present, and 5-year change in inconsistency. The questionnaire showed acceptable psychometric characteristics. The sample reported an increase in perceived inconsistency over time. Higher reported present inconsistency and greater 5-year increase in inconsistency were associated with noncognitive (e.g., older age, poorer ADLs, poorer health, higher depression), metacognitive (e.g., poorer self-rated memory) and neuropsychological (e.g., poorer performance and greater 5-year decline in global cognitive status, vocabulary, and memory) measures. Correlations between self-reported inconsistency and neuropsychological performance were attenuated, but largely persisted when self-rated memory and age were controlled. Observed relationships between self-reported inconsistency and measures of neuropsychological (including memory) status and decline suggest that self-perceived inconsistency may be an area of relevance in evaluating older adults for memory disorders.

  5. Validity of self-reported adult secondhand smoke exposure.

    Science.gov (United States)

    Prochaska, Judith J; Grossman, William; Young-Wolff, Kelly C; Benowitz, Neal L

    2015-01-01

    Exposure of adults to secondhand smoke (SHS) has immediate adverse effects on the cardiovascular system and causes coronary heart disease. The current study evaluated brief self-report screening measures for accurately identifying adult cardiology patients with clinically significant levels of SHS exposure in need of intervention. A cross-sectional study conducted in a university-affiliated cardiology clinic and cardiology inpatient service. Participants were 118 non-smoking patients (59% male, mean age=63.6 years, SD=16.8) seeking cardiology services. Serum cotinine levels and self-reported SHS exposure in the past 24 h and 7 days on 13 adult secondhand exposure to smoke (ASHES) items. A single item assessment of SHS exposure in one's own home in the past 7 days was significantly correlated with serum cotinine levels (r=0.41, p85% and correct classification rates >85% at cotinine cut-off points of >0.215 and >0.80 ng/mL. The item outperformed multi-item scales, an assessment of home smoking rules, and SHS exposure assessed in other residential areas, automobiles and public settings. The sample was less accurate at self-reporting lower levels of SHS exposure (cotinine 0.05-0.215 ng/mL). The single item ASHES-7d Home screener is brief, assesses recent SHS exposure over a week's time, and yielded the optimal balance of sensitivity and specificity. The current findings support use of the ASHES-7d Home screener to detect SHS exposure and can be easily incorporated into assessment of other major vital signs in cardiology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Self-reported Medication Adherence and CKD Progression

    Directory of Open Access Journals (Sweden)

    Esteban A. Cedillo-Couvert

    2018-05-01

    Full Text Available Introduction: In the general population, medication nonadherence contributes to poorer outcomes. However, little is known about medication adherence among adults with chronic kidney disease (CKD. We evaluated the association of self-reported medication adherence with CKD progression and all-cause death in patients with CKD. Methods: In this prospective observational study of 3305 adults with mild-to-moderate CKD enrolled in the Chronic Renal Insufficiency Cohort (CRIC Study, the baseline self-reported medication adherence was assessed by responses to 3 questions and categorized as high, medium, and low. CKD progression (50% decline in eGFR or incident end-stage renal disease and all-cause death were measured using multivariable Cox proportional hazards. Results: Of the patients, 68% were categorized as high adherence, 17% medium adherence, and 15% low adherence. Over a median follow-up of 6 years, there were 969 CKD progression events and 675 deaths. Compared with the high-adherence group, the low-adherence group experienced increased risk for CKD progression (hazard ratio = 1.27, 95% confidence interval = 1.05, 1.54 after adjustment for sociodemographic and clinical factors, cardiovascular medications, number of medication types, and depressive symptoms. A similar association existed between low adherence and all-cause death, but did not reach standard statistical significance (hazard ratio = 1.14 95% confidence interval = 0.88, 1.47. Conclusion: Baseline self-reported low medication adherence was associated with an increased risk for CKD progression. Future work is needed to better understand the mechanisms underlying this association and to develop interventions to improve adherence. Keywords: CKD, death, medication adherence, progression

  7. Subjective Cognitive Decline in Older Adults: An Overview of Self-Report Measures Used Across 19 International Research Studies

    Science.gov (United States)

    Rabin, Laura A.; Smart, Colette M.; Crane, Paul K.; Amariglio, Rebecca E.; Berman, Lorin M.; Boada, Mercè; Buckley, Rachel F.; Chételat, Gaël; Dubois, Bruno; Ellis, Kathryn A.; Gifford, Katherine A.; Jefferson, Angela L.; Jessen, Frank; Katz, Mindy J.; Lipton, Richard B.; Luck, Tobias; Maruff, Paul; Mielke, Michelle M.; Molinuevo, José Luis; Naeem, Farnia; Perrotin, Audrey; Petersen, Ronald C.; Rami, Lorena; Reisberg, Barry; Rentz, Dorene M.; Riedel-Heller, Steffi G.; Risacher, Shannon L.; Rodriguez, Octavio; Sachdev, Perminder S.; Saykin, Andrew J.; Slavin, Melissa J.; Snitz, Beth E.; Sperling, Reisa A.; Tandetnik, Caroline; van der Flier, Wiesje M.; Wagner, Michael; Wolfsgruber, Steffen; Sikkes, Sietske A.M.

    2015-01-01

    Research increasingly suggests that subjective cognitive decline (SCD) in older adults, in the absence of objective cognitive dysfunction or depression, may be a harbinger of non-normative cognitive decline and eventual progression to dementia. Little is known, however, about the key features of self-report measures currently used to assess SCD. The Subjective Cognitive Decline Initiative (SCD-I) Working Group is an international consortium established to develop a conceptual framework and research criteria for SCD (Jessen et al., 2014, Alzheimers Dement 10, 844–852). In the current study we systematically compared cognitive self-report items used by 19 SCD-I Working Group studies, representing 8 countries and 5 languages. We identified 34 self-report measures comprising 640 cognitive self-report items. There was little overlap among measures—approximately 75% of measures were used by only one study. Wide variation existed in response options and item content. Items pertaining to the memory domain predominated, accounting for about 60% of items surveyed, followed by executive function and attention, with 16% and 11% of the items, respectively. Items relating to memory for the names of people and the placement of common objects were represented on the greatest percentage of measures (56% each). Working group members reported that instrument selection decisions were often based on practical considerations beyond the study of SCD specifically, such as availability and brevity of measures. Results document the heterogeneity of approaches across studies to the emerging construct of SCD. We offer preliminary recommendations for instrument selection and future research directions including identifying items and measure formats associated with important clinical outcomes. PMID:26402085

  8. Adjusting to future demands in healthcare: Curriculum changes and nursing students' self-reported professional competence.

    Science.gov (United States)

    Theander, Kersti; Wilde-Larsson, Bodil; Carlsson, Marianne; Florin, Jan; Gardulf, Ann; Johansson, Eva; Lindholm, Christina; Nordström, Gun; Nilsson, Jan

    2016-02-01

    Nursing competence is of significant importance for patient care. Newly graduated nursing students rate their competence as high. However, the impact of different designs of nursing curricula on nursing students' self-reported nursing competence areas is seldom reported. To compare newly graduated nursing students' self-reported professional competence before and after the implementation of a new nursing curriculum. The study had a descriptive comparative design. Nursing students, who graduated in 2011, having studied according to an older curriculum, were compared with those who graduated in 2014, after a new nursing curriculum with more focus on person-centered nursing had been implemented. A higher education nursing program at a Swedish university. In total, 119 (2011 n=69, 2014 n=50) nursing students responded. Nursing students' self-reported professional competencies were assessed with the Nurse Professional Competence (NPC) scale. There were no significant differences between the two groups of nursing students, who graduated in 2011 and 2014, respectively, with regard to age, sex, education, or work experience. Both groups rated their competencies as very high. Competence in value-based nursing was perceived to be significantly higher after the change in curriculum. The lowest competence, both in 2011 and 2014, was reported in education and supervision of staff and students. Our findings indicate that newly graduated nursing students - both those following the old curriculum and the first batch of students following the new one - perceive that their professional competence is high. Competence in value-based nursing, measured with the NPC scale, was reported higher after the implementation of a new curriculum, reflecting curriculum changes with more focus on person-centered nursing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Detailed design and first tests of the application software for the instrument control unit of Euclid-NISP

    Science.gov (United States)

    Ligori, S.; Corcione, L.; Capobianco, V.; Bonino, D.; Sirri, G.; Fornari, F.; Giacomini, F.; Patrizii, L.; Valenziano, L.; Travaglini, R.; Colodro, C.; Bortoletto, F.; Bonoli, C.; Chiarusi, T.; Margiotta, A.; Mauri, N.; Pasqualini, L.; Spurio, M.; Tenti, M.; Dal Corso, F.; Dusini, S.; Laudisio, F.; Sirignano, C.; Stanco, L.; Ventura, S.; Auricchio, N.; Balestra, A.; Franceschi, E.; Morgante, G.; Trifoglio, M.; Medinaceli, E.; Guizzo, G. P.; Debei, S.; Stephen, J. B.

    2016-07-01

    In this paper we describe the detailed design of the application software (ASW) of the instrument control unit (ICU) of NISP, the Near-Infrared Spectro-Photometer of the Euclid mission. This software is based on a real-time operating system (RTEMS) and will interface with all the subunits of NISP, as well as the command and data management unit (CDMU) of the spacecraft for telecommand and housekeeping management. We briefly review the main requirements driving the design and the architecture of the software that is approaching the Critical Design Review level. The interaction with the data processing unit (DPU), which is the intelligent subunit controlling the detector system, is described in detail, as well as the concept for the implementation of the failure detection, isolation and recovery (FDIR) algorithms. The first version of the software is under development on a Breadboard model produced by AIRBUS/CRISA. We describe the results of the tests and the main performances and budgets.

  10. The impact of instrumentation and control requirements on the design changes of the Westinghouse ''NSSS'' of Almaraz, Lemoniz and Asco

    International Nuclear Information System (INIS)

    Gerini, P.M.; Naredo, F.P.; Williams, D.W.

    1978-01-01

    For the nuclear power plants Almaraz, Lemoniz and Asco the NSSS set is supplied by Westinghouse. Purchasing contracts were signed in 1971 and projects design took into account the compliance with the regulatory requirements for licensing, issued and standing that time. Since 1971 licensing regulations have been subjected to a deep revision due to the issue of new standards and guides and revision of other affecting altogether the engineering design of nuclear power plants. This situation was reasonably reflected on several consecutive design revisions for the case of the Almaraz, Lemoniz and Asco Nuclear plants. This impact, from the viewpoint of the instrumentation and control context, and referred to the NSSS is analyzed in the report. In particular, attention is paid to the safeguards actuation logic, testing capability and physical separation criteria as contemplated into the regulatory requirements starting from 1971.(J.E.de C)

  11. Validity of self-reported exposure to shift work.

    Science.gov (United States)

    Härmä, Mikko; Koskinen, Aki; Ropponen, Annina; Puttonen, Sampsa; Karhula, Kati; Vahtera, Jussi; Kivimäki, Mika

    2017-03-01

    To evaluate the validity of widely used questionnaire items on work schedule using objective registry data as reference. A cohort study of hospital employees who responded to a self-administered questionnaire on work schedule in 2008, 2012 and 2014 and were linked to individual-level pay-roll-based records on work shifts. For predictive validity, leisure-time fatigue was assessed. According to the survey data in 2014 (n=8896), 55% of the day workers had at least 1 year of earlier shift work experience. 8% of the night shift workers changed to day work during the follow-up. Using pay-roll data as reference, questions on 'shift work with night shifts' and 'permanent night work' showed high sensitivity (96% and 90%) and specificity (92% and 97%). Self-reported 'regular day work' showed moderate sensitivity (73%), but high specificity (99%) and 'shift work without night shifts' showed low sensitivity (62%) and moderate specificity (87%). In multivariate logistic regression analysis, the age-adjusted, sex-adjusted and baseline fatigue-adjusted association between 'shift work without night shifts' and leisure-time fatigue was lower for self-reported compared with objective assessment (1.30, 95% CI 0.94 to 1.82, n=1707 vs 1.89, 95% CI 1.06 to 3.39, n=1627). In contrast, shift work with night shifts, compared with permanent day work, was similarly associated with fatigue in the two assessments (2.04, 95% CI 1.62 to 2.57, n=2311 vs 1.82, 95% CI 1.28 to 2.58, n=1804). The validity of self-reported assessment of shift work varies between work schedules. Exposure misclassification in self-reported data may contribute to bias towards the null in shift work without night shifts. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Opto-mechanical design of optical window for aero-optics effect simulation instruments

    Science.gov (United States)

    Wang, Guo-ming; Dong, Dengfeng; Zhou, Weihu; Ming, Xing; Zhang, Yan

    2016-10-01

    A complete theory is established for opto-mechanical systems design of the window in this paper, which can make the design more rigorous .There are three steps about the design. First, the universal model of aerodynamic environment is established based on the theory of Computational Fluid Dynamics, and the pneumatic pressure distribution and temperature data of optical window surface is obtained when aircraft flies in 5-30km altitude, 0.5-3Ma speed and 0-30°angle of attack. The temperature and pressure distribution values for the maximum constraint is selected as the initial value of external conditions on the optical window surface. Then, the optical window and mechanical structure are designed, which is also divided into two parts: First, mechanical structure which meet requirements of the security and tightness is designed. Finally, rigorous analysis and evaluation are given about the structure of optics and mechanics we have designed. There are two parts to be analyzed. First, the Fluid-Solid-Heat Coupled Model is given based on finite element analysis. And the deformation of the glass and structure can be obtained by the model, which can assess the feasibility of the designed optical windows and ancillary structure; Second, the new optical surface is fitted by Zernike polynomials according to the deformation of the surface of the optical window, which can evaluate imaging quality impact of spectral camera by the deformation of window.

  13. Criterion-related validity of self-reported stair climbing in older adults.

    Science.gov (United States)

    Higueras-Fresnillo, Sara; Esteban-Cornejo, Irene; Gasque, Pablo; Veiga, Oscar L; Martinez-Gomez, David

    2018-02-01

    Stair climbing is an activity of daily living that might contribute to increase levels of physical activity (PA). To date, there is no study examining the validity of climbing stairs assessed by self-report. The aim of this study was, therefore, to examine the validity of estimated stair climbing from one question included in a common questionnaire compared to a pattern-recognition activity monitor in older adults. A total of 138 older adults (94 women), aged 65-86 years (70.9 ± 4.7 years), from the IMPACT65 + study participated in this validity study. Estimates of stair climbing were obtained from the European Prospective Investigation into Cancer and Nutrition (EPIC) PA questionnaire. An objective assessment of stair climbing was obtained with the Intelligent Device for Energy Expenditure and Activity (IDEEA) monitor. The correlation between both methods to assess stair climbing was fair (ρ = 0.22, p = 0.008 for PA energy expenditure and ρ = 0.26, p = 0.002 for duration). Mean differences between self-report and the IDEEA were 7.96 ± 10.52 vs. 9.88 ± 3.32 METs-min/day for PA energy expenditure, and 0.99 ± 1.32 vs. 1.79 ± 2.02 min/day for duration (both Wilcoxon test p < 0.001). Results from the Bland-Altman analysis indicate that bias between both instruments were -1.91 ± 10.30 METs-min/day and -0.80 ± 1.99 min/day, and corresponding limits of agreement for the two instruments were from 18.27 to -22.10 METs-min/day and from 3.09 to -4.70 min/day, respectively. Our results indicate that self-reported stair climbing has modest validity to accurately rank old age participants, and underestimates both PAEE and its duration, as compared with an objectively measured method.

  14. Measuring adult picky eating: The development of a multidimensional self-report instrument.

    Science.gov (United States)

    Ellis, Jordan M; Galloway, Amy T; Webb, Rose Mary; Martz, Denise M

    2017-08-01

    A brief multidimensional measure of adult picky eating (PE) behavior was developed using a large U.S. adult sample. In addition, the study explored associations between specific aspects of adult PE behavior and psychosocial impairment in effort to support the inclusion of adults in the Diagnostic and Statistical Manual for Mental Disorders-Fifth Edition (DSM-5) avoidant-restrictive food intake disorder (ARFID). The study included 3 phases of qualitative and quantitative data collection. Participants were 1,663 U.S. adults who completed online surveys. Exploratory and confirmatory factor analyses were used to develop PE subscales. Associations among the PE subscales and measures of psychosocial impairment were examined. Exploratory and confirmatory factor analysis supported a 16-item 4-factor model of adult PE that included subscales of meal presentation, food variety, meal disengagement, and taste aversion. The measure also demonstrated convergence with previous measures of PE. The meal disengagement and meal presentation subscales demonstrated significant associations with social eating anxiety, anxiety sensitivity, eating related quality of life (QOL), and psychological flexibility. Meal disengagement alone was significantly associated with depressive symptoms. The Adult Picky Eating Questionnaire (APEQ) demonstrated sound psychometric properties and may be used to further investigate adult PE behavior. The relationships between adult PE and psychological impairment, particularly social anxiety, support the inclusion of ARFID in the DSM-5. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. Conceptual design of the X-IFU Instrument Control Unit on board the ESA Athena mission

    Science.gov (United States)

    Corcione, L.; Ligori, S.; Capobianco, V.; Bonino, D.; Valenziano, L.; Guizzo, G. P.

    2016-07-01

    Athena is one of L-class missions selected in the ESA Cosmic Vision 2015-2025 program for the science theme of the Hot and Energetic Universe. The Athena model payload includes the X-ray Integral Field Unit (X-IFU), an advanced actively shielded X-ray microcalorimeter spectrometer for high spectral resolution imaging, utilizing cooled Transition Edge Sensors. This paper describes the preliminary architecture of Instrument Control Unit (ICU), which is aimed at operating all XIFU's subsystems, as well as at implementing the main functional interfaces of the instrument with the S/C control unit. The ICU functions include the TC/TM management with S/C, science data formatting and transmission to S/C Mass Memory, housekeeping data handling, time distribution for synchronous operations and the management of the X-IFU components (i.e. CryoCoolers, Filter Wheel, Detector Readout Electronics Event Processor, Power Distribution Unit). ICU functions baseline implementation for the phase-A study foresees the usage of standard and Space-qualified components from the heritage of past and current space missions (e.g. Gaia, Euclid), which currently encompasses Leon2/Leon3 based CPU board and standard Space-qualified interfaces for the exchange commands and data between ICU and X-IFU subsystems. Alternative architecture, arranged around a powerful PowerPC-based CPU, is also briefly presented, with the aim of endowing the system with enhanced hardware resources and processing power capability, for the handling of control and science data processing tasks not defined yet at this stage of the mission study.

  16. Alcohol consumption and self-reported (SF12) physical and mental health among working aged-men in a typical Russian city

    DEFF Research Database (Denmark)

    Dissing, Nete; Gil, Artyom; Keenan, Katherine

    2013-01-01

    the associations with PCS considerably. CONCLUSION: Among working age male adults in Russia, hazardous patterns of alcohol drinking are associated with poorer self-reported physical health, and even more strongly with poorer self-reported mental health. Physical health appears to be lower in those reporting......AIM: To investigate the association between patterns of alcohol consumption and self-reported physical and mental health in a population with a high prevalence of hazardous drinking. DESIGN: Cross-sectional study of an age-stratified random sample of a population register. SETTING: The city...... of Izhevsk, The Russian Federation, 2008-9. PARTICIPANTS: 1031 men aged 25 to 60 years (68% response rate). MEASUREMENTS: Self-reported health was evaluated with the SF12 physical (PCS) and mental (MCS) component summaries. Measures of hazardous drinking (based on frequency of adverse effects of alcohol...

  17. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  18. Walking smoothness is associated with self-reported function after accounting for gait speed.

    Science.gov (United States)

    Lowry, Kristin A; Vanswearingen, Jessie M; Perera, Subashan; Studenski, Stephanie A; Brach, Jennifer S

    2013-10-01

    Gait speed has shown to be an indicator of functional status in older adults; however, there may be aspects of physical function not represented by speed but by the quality of movement. The purpose of this study was to determine the relations between walking smoothness, an indicator of the quality of movement based on trunk accelerations, and physical function. Thirty older adults (mean age, 77.7±5.1 years) participated. Usual gait speed was measured using an instrumented walkway. Walking smoothness was quantified by harmonic ratios derived from anteroposterior, vertical, and mediolateral trunk accelerations recorded during overground walking. Self-reported physical function was recorded using the function subscales of the Late-Life Function and Disability Instrument. Anteroposterior smoothness was positively associated with all function components of the Late-Life Function and Disability Instrument, whereas mediolateral smoothness exhibited negative associations. Adjusting for gait speed, anteroposterior smoothness remained associated with the overall and lower extremity function subscales, whereas mediolateral smoothness remained associated with only the advanced lower extremity subscale. These findings indicate that walking smoothness, particularly the smoothness of forward progression, represents aspects of the motor control of walking important for physical function not represented by gait speed alone.

  19. CAS-ATLID (co-alignment sensor of ATLID instrument) thermo-structural design and performance

    Science.gov (United States)

    Moreno, Javier; Serrano, Javier; González, David; Rodríguez, Gemma; Manjón, Andrés.; Vásquez, Eloi; Carretero, Carlos; Martínez, Berta

    2017-11-01

    This paper describes the main thermo-mechanical design features and performances of the Co-Alignment Sensor (CAS) developed by LIDAX and CRISA under ESA program with AIRBUS Defence and Space as industry prime.

  20. Evolving a Method to Capture Science Stakeholder Inputs to Optimize Instrument, Payload, and Program Design

    Science.gov (United States)

    Clark, P. E.; Rilee, M. L.; Curtis, S. A.; Bailin, S.

    2012-03-01

    We are developing Frontier, a highly adaptable, stably reconfigurable, web-accessible intelligent decision engine capable of optimizing design as well as the simulating operation of complex systems in response to evolving needs and environment.

  1. Beamline Design and Instrumentation for the Imaging and Coherence Beamline I13L at the Diamond Light Source

    Science.gov (United States)

    Wagner, U. H.; Pešić, Z. D.; De Fanis, A.; Rau, C.

    2013-03-01

    I13L is a 250 m long hard x-ray beamline (6 keV to 35 keV) at the Diamond Light Source. The beamline comprises of two independent experimental endstations: one for imaging in direct space using x-ray microscopy and one for imaging in reciprocal space using coherent diffraction based imaging techniques. In this paper we will discuss the fundamental design concepts of the beamline and explain their implications for the civil engineering of the endstation building and the beamline instrumentation. For the latter this paper will focus on the beamline mirror systems and monochromators.

  2. Beamline Design and Instrumentation for the Imaging and Coherence Beamline I13L at the Diamond Light Source

    International Nuclear Information System (INIS)

    Wagner, U H; Pešić, Z D; Fanis, A De; Rau, C

    2013-01-01

    I13L is a 250 m long hard x-ray beamline (6 keV to 35 keV) at the Diamond Light Source. The beamline comprises of two independent experimental endstations: one for imaging in direct space using x-ray microscopy and one for imaging in reciprocal space using coherent diffraction based imaging techniques. In this paper we will discuss the fundamental design concepts of the beamline and explain their implications for the civil engineering of the endstation building and the beamline instrumentation. For the latter this paper will focus on the beamline mirror systems and monochromators.

  3. Design of shared instruments to utilize simulated gravities generated by a large-gradient, high-field superconducting magnet.

    Science.gov (United States)

    Wang, Y; Yin, D C; Liu, Y M; Shi, J Z; Lu, H M; Shi, Z H; Qian, A R; Shang, P

    2011-03-01

    A high-field superconducting magnet can provide both high-magnetic fields and large-field gradients, which can be used as a special environment for research or practical applications in materials processing, life science studies, physical and chemical reactions, etc. To make full use of a superconducting magnet, shared instruments (the operating platform, sample holders, temperature controller, and observation system) must be prepared as prerequisites. This paper introduces the design of a set of sample holders and a temperature controller in detail with an emphasis on validating the performance of the force and temperature sensors in the high-magnetic field.

  4. The effect of regulatory requirements on the control and instrumentation system designer

    International Nuclear Information System (INIS)

    Golder, J.A.

    1978-01-01

    The difficulties encountered by the designer of control and protection systems for nuclear plant in attempting to satisfy the large number of imprecise regulations and recommendations which exist are described. The absence of fundamental quantitative safety requirements of international acceptability is deplored and the adoption of a major incident criteria expressed in quantitative terms as the basis for the derivation of target design criteria for protection systems and plant components is suggested. (author)

  5. A Comparison of the McMaster and Circumplex Family Assessment Instruments.

    Science.gov (United States)

    Fristad, Mary A.

    1989-01-01

    Compared clinical rating scales and self-report scales from McMaster and Circumplex models of family functioning with families (N=41). Found McMaster instruments had superior sensitivity; greater correspondence between clinical rating scales and family member self-report inventories on McMaster instruments; and lack of support for the curvilinear…

  6. In-core Instrument Subcritical Verification (INCISV) - Core Design Verification Method - 358

    International Nuclear Information System (INIS)

    Prible, M.C.; Heibel, M.D.; Conner, S.L.; Sebastiani, P.J.; Kistler, D.P.

    2010-01-01

    According to the standard on reload startup physics testing, ANSI/ANS 19.6.1, a plant must verify that the constructed core behaves sufficiently close to the designed core to confirm that the various safety analyses bound the actual behavior of the plant. A large portion of this verification must occur before the reactor operates at power. The INCISV Core Design Verification Method uses the unique characteristics of a Westinghouse Electric Company fixed in-core self powered detector design to perform core design verification after a core reload before power operation. A Vanadium self powered detector that spans the length of the active fuel region is capable of confirming the required core characteristics prior to power ascension; reactivity balance, shutdown margin, temperature coefficient and power distribution. Using a detector element that spans the length of the active fuel region inside the core provides a signal of total integrated flux. Measuring the integrated flux distributions and changes at various rodded conditions and plant temperatures, and comparing them to predicted flux levels, validates all core necessary core design characteristics. INCISV eliminates the dependence on various corrections and assumptions between the ex-core detectors and the core for traditional physics testing programs. This program also eliminates the need for special rod maneuvers which are infrequently performed by plant operators during typical core design verification testing and allows for safer startup activities. (authors)

  7. Progress in XRCS-Survey plant instrumentation and control design for ITER

    International Nuclear Information System (INIS)

    Varshney, Sanjeev; Jha, Shivakant; Simrock, Stefan; Barnsley, Robin; Martin, Vincent; Mishra, Sapna; Patil, Prabhakant; Patel, Shreyas; Kumar, Vinay

    2016-01-01

    Highlights: • An identification of the major process functions system compliant to Plant Control Design Handbook (PCDH) has been made for XRCS-Survey plant I&C. • I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using Enterprise architect (EA). • I&C architecture, interface with ITER networks and Plants, configuration of cubicles are discussed towards nine design review deliverables. - Abstract: A real time, plasma impurity survey system based on X-ray Crystal Spectroscopy (XRCS) has been designed for ITER and will be made available in the set of first plasma diagnostics for measuring impurity ion concentrations and their in-flux. For the purpose of developing a component level design of XRCS-Survey plant I&C system that is compliant to the rules and guidelines defined in the Plant Control Design Handbook (PCDH), firstly an identification of the major process functions has been made. The preliminary plant I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using a system engineering tool, Enterprise Architect (EA). Conceptual I&C architecture, interface with the ITER networks and other Plants have been discussed along with the basic configuration of I&C cubicles aiming towards nine I&C deliverables for the design review.

  8. Progress in XRCS-Survey plant instrumentation and control design for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Varshney, Sanjeev, E-mail: sanjeev.varshney@iter-india.org [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India); Jha, Shivakant [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India); Simrock, Stefan; Barnsley, Robin; Martin, Vincent [ITER-Organization, Route de Vinon sur Verdon, CS 90 046, 13067 St. Paul-Lez-Durance, Cedex (France); Mishra, Sapna [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India); Patil, Prabhakant [ITER-Organization, Route de Vinon sur Verdon, CS 90 046, 13067 St. Paul-Lez-Durance, Cedex (France); Patel, Shreyas; Kumar, Vinay [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India)

    2016-11-15

    Highlights: • An identification of the major process functions system compliant to Plant Control Design Handbook (PCDH) has been made for XRCS-Survey plant I&C. • I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using Enterprise architect (EA). • I&C architecture, interface with ITER networks and Plants, configuration of cubicles are discussed towards nine design review deliverables. - Abstract: A real time, plasma impurity survey system based on X-ray Crystal Spectroscopy (XRCS) has been designed for ITER and will be made available in the set of first plasma diagnostics for measuring impurity ion concentrations and their in-flux. For the purpose of developing a component level design of XRCS-Survey plant I&C system that is compliant to the rules and guidelines defined in the Plant Control Design Handbook (PCDH), firstly an identification of the major process functions has been made. The preliminary plant I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using a system engineering tool, Enterprise Architect (EA). Conceptual I&C architecture, interface with the ITER networks and other Plants have been discussed along with the basic configuration of I&C cubicles aiming towards nine I&C deliverables for the design review.

  9. TROPOMI, the Sentinel 5 precursor instrument for air quality and climate observations: status of the current design

    Science.gov (United States)

    Voors, Robert; de Vries, Johan; Bhatti, Ianjit S.; Lobb, Dan; Wood, Trevor; van der Valk, Nick; Aben, Ilse; Veefkind, Pepijn

    2017-11-01

    TROPOMI, the Tropospheric Monitoring Instrument, is a passive UV-VIS-NIR-SWIR trace gas spectrograph in the line of SCIAMACHY (2002) and OMI (2004), instruments with the Netherlands in a leading role. Both instruments are very successful and remained operational long after their nominal life time. TROPOMI is the next step, scheduled for launch in 2015. It combines the broad wavelength range from SCIAMACHY from UV to SWIR and the broad viewing angle push-broom concept from OMI, which makes daily global coverage in combination with good spatial resolution possible. Using spectral bands from 270-500nm (UV-VIS) 675-775nm (NIR) and 2305-2385nm (SWIR) at moderate resolution (0.25 to 0.6nm) TROPOMI will measure O3, NO2, SO2, BrO, HCHO and H2O tropospheric columns from the UV-VIS-NIR wavelength range and CO and CH4 tropospheric columns from the SWIR wavelength range. Cloud information will be derived primarily from the O2A band in the NIR. This will help, together with the aerosol information, in constraining the light path of backscattered solar radiation. Methane (CH4), CO2 and Carbon monoxide (CO) are the key gases of the global carbon cycle. Of these, Methane is by far the least understood in terms of its sources and is most difficult to predict its future trend. Global space observations are needed to inform atmospheric models. The SWIR channel of TROPOMI is designed to achieve the spectral, spatial and SNR resolution required for this task. TROPOMI will yield an improved accuracy of the tropospheric products compared to the instruments currently in orbit. TROPOMI will take a major step forward in spatial resolution and sensitivity. The nominal observations are at 7 x 7 km2 at nadir and the signal-to-noises are sufficient for trace gas retrieval even at very low albedos (down to 2%). This spatial resolution allows observation of air quality at sub-city level and the high signal-to-noises means that the instrument can perform useful measurements in the darkest

  10. Self-Reported Health Among Recently Incarcerated Mothers.

    Science.gov (United States)

    Turney, Kristin; Wildeman, Christopher

    2015-10-01

    We examined self-reported health among formerly incarcerated mothers. We used data from the Fragile Families and Child Wellbeing Study (n = 4096), a longitudinal survey of mostly unmarried parents in urban areas, to estimate the association between recent incarceration (measured as any incarceration in the past 4 years) and 5 self-reported health conditions (depression, illicit drug use, heavy drinking, fair or poor health, and health limitations), net of covariates including health before incarceration. In adjusted logistic regression models, recently incarcerated mothers, compared with their counterparts, have an increased likelihood of depression (odds ratio [OR] = 1.60; 95% confidence interval [CI] = 1.18, 2.17), heavy drinking (OR = 1.79; 95% CI = 1.19, 2.68), fair or poor health (OR = 1.49; 95% CI = 1.08, 2.06), and health limitations (OR = 1.78; 95% CI = 1.27, 2.50). This association is similar across racial/ethnic subgroups and is larger among mothers who share children with fathers who have not been recently incarcerated. Recently incarcerated mothers struggle with even more health conditions than expected given the disadvantages they experience before incarceration. Furthermore, because incarceration is concentrated among those who are most disadvantaged, incarceration may increase inequalities in population health.

  11. Self-Reported Acute and Chronic Voice Disorders in Teachers.

    Science.gov (United States)

    Rossi-Barbosa, Luiza Augusta Rosa; Barbosa, Mirna Rossi; Morais, Renata Martins; de Sousa, Kamilla Ferreira; Silveira, Marise Fagundes; Gama, Ana Cristina Côrtes; Caldeira, Antônio Prates

    2016-11-01

    The present study aimed to identify factors associated with self-reported acute and chronic voice disorders among municipal elementary school teachers in the city of Montes Claros, in the State of Minas Gerais, Brazil. The dependent variable, self-reported dysphonia, was determined via a single question, "Have you noticed changes in your voice quality?" and if so, a follow-up question queried the duration of this change, acute or chronic. The independent variables were dichotomized and divided into five categories: sociodemographic and economic data; lifestyle; organizational and environmental data; health-disease processes; and voice. Analyses of associated factors were performed via a hierarchical multiple logistic regression model. The present study included 226 teachers, of whom 38.9% reported no voice disorders, 35.4% reported an acute disorder, and 25.7% reported a chronic disorder. Excessive voice use daily, consuming more than one alcoholic drink per time, and seeking medical treatment because of voice disorders were associated factors for acute and chronic voice disorders. Consuming up to three glasses of water per day was associated with acute voice disorders. Among teachers who reported chronic voice disorders, teaching for over 15 years and the perception of disturbing or unbearable noise outside the school were both associated factors. Identification of organizational, environmental, and predisposing risk factors for voice disorders is critical, and furthermore, a vocal health promotion program may address these issues. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  12. Smartphone addiction, daily interruptions and self-reported productivity

    Directory of Open Access Journals (Sweden)

    Éilish Duke

    2017-12-01

    Full Text Available The advent of the smartphone has dramatically altered how we communicate, navigate, work and entertain ourselves. While the advantages of this new technology are clear, constant use may also bring negative consequences, such as a loss of productivity due to interruptions in work life. A link between smartphone overuse and loss of productivity has often been hypothesized, but empirical evidence on this question is scarce. The present study addressed this question by collecting self-report data from N=262 participants, assessing private and work-related smartphone use, smartphone addiction and self-rated productivity. Our results indicate a moderate relationship between smartphone addiction and a self-reported decrease in productivity due to spending time on the smartphone during work, as well as with the number of work hours lost to smartphone use. Smartphone addiction was also related to a greater amount of leisure time spent on the smartphone and was strongly related to a negative impact of smartphone use on daily non-work related activities. These data support the idea that tendencies towards smartphone addiction and overt checking of the smartphone could result in less productivity both in the workplace and at home. Results are discussed in relation to productivity and technostress.

  13. Smartphone addiction, daily interruptions and self-reported productivity.

    Science.gov (United States)

    Duke, Éilish; Montag, Christian

    2017-12-01

    The advent of the smartphone has dramatically altered how we communicate, navigate, work and entertain ourselves. While the advantages of this new technology are clear, constant use may also bring negative consequences, such as a loss of productivity due to interruptions in work life. A link between smartphone overuse and loss of productivity has often been hypothesized, but empirical evidence on this question is scarce. The present study addressed this question by collecting self-report data from N  = 262 participants, assessing private and work-related smartphone use, smartphone addiction and self-rated productivity. Our results indicate a moderate relationship between smartphone addiction and a self-reported decrease in productivity due to spending time on the smartphone during work, as well as with the number of work hours lost to smartphone use. Smartphone addiction was also related to a greater amount of leisure time spent on the smartphone and was strongly related to a negative impact of smartphone use on daily non-work related activities. These data support the idea that tendencies towards smartphone addiction and overt checking of the smartphone could result in less productivity both in the workplace and at home. Results are discussed in relation to productivity and technostress.

  14. Self-Reported Disability in Adults with Severe Obesity

    Directory of Open Access Journals (Sweden)

    I. Kyrou

    2011-01-01

    Full Text Available Self-reported disability in performing daily life activities was assessed in adults with severe obesity (BMI ≥ 35 kg/m2 using the Health Assessment Questionnaire (HAQ. 262 participants were recruited into three BMI groups: Group I: 35–39.99 kg/m2; Group II: 40–44.99 kg/m2; Group III: ≥45.0 kg/m2. Progressively increasing HAQ scores were documented with higher BMI; Group I HAQ score: 0.125 (median (range: 0–1.75; Group II HAQ score: 0.375 (0–2.5; Group III HAQ score: 0.75 (0–2.65 (Group III versus II P 0. The prevalence of this degree of disability increased with increasing BMI and age. It also correlated to type 2 diabetes, metabolic syndrome, and clinical depression, but not to gender. Our data suggest that severe obesity is associated with self-reported disability in performing common daily life activities, with increasing degree of disability as BMI increases over 35 kg/m2. Functional assessment is crucial in obesity management, and establishing the disability profiles of obese patients is integral to both meet the specific healthcare needs of individuals and develop evidence-based public health programs, interventions, and priorities.

  15. Self-reported occupational physical activity and cardiorespiratory fitness

    DEFF Research Database (Denmark)

    Holtermann, Andreas; Marott, Jacob Louis; Gyntelberg, Finn

    2016-01-01

    OBJECTIVES: This study aimed to investigate whether workers with the combination of high occupational physical activity (OPA) and low cardiorespiratory fitness have an increased risk of cardiovascular disease (CVD) and all-cause mortality. METHODS: Using multivariable Cox proportional hazards......) and cardiorespiratory fitness (low, same and higher as peers) at baseline. RESULTS: During a median follow-up of 18.5 years, 257 and 852 individuals died from CVD and any cause, respectively. In the fully-adjusted model, an increased risk for CVD mortality was found for those with low compared to high self......-reported cardiorespiratory fitness [hazard ratio (HR) 2.17, 95% confidence interval (95% CI) 1.40-3.38), for those with high compared to low OPA (HR 1.45, 95% CI 1.05-2.00), and for those with high compared to low OPA within the strata of low self-reported cardiorespiratory fitness (HR 2.83, 95% CI 1.24-6.46). Moreover...

  16. Vernier Caliper and Micrometer Computer Models Using Easy Java Simulation and Its Pedagogical Design Features--Ideas for Augmenting Learning with Real Instruments

    Science.gov (United States)

    Wee, Loo Kang; Ning, Hwee Tiang

    2014-01-01

    This paper presents the customization of Easy Java Simulation models, used with actual laboratory instruments, to create active experiential learning for measurements. The laboratory instruments are the vernier caliper and the micrometer. Three computer model design ideas that complement real equipment are discussed. These ideas involve (1) a…

  17. Instrumentalization of origami in construction of folded plate structures - design, research and education

    Directory of Open Access Journals (Sweden)

    Nestorović Miodrag

    2016-01-01

    Full Text Available The paper deals with the origami used as an abstract tool to describe and represent the form and the structure of physical objects. In that respect, the potentials of this interdisciplinary technique as a medium of exploration of structural forms was introduced in the semester project done within the course Structural Systems at the Belgrade University, Faculty of Architecture. The technique was used as an interface to gain cognitive experience on spatial transformation and computational design. Throughout the intensive project period divided into three successive stages, the objective was to test method which enabled students to analyze geometrical principles of folding in order to apply these principles in the development of new designs. The generative algorithm inspired by the technique of paper folding assisted form-finding. Resulting shapes were verified by a production of small scale prototype models. The applied method, as a guiding design principle, facilitated formal exploration and augmentation of the design process. At the end of the course, students got cognitive experience on structural forms, while this simple technique delivered richness in terms of design solutions. [Projekat Ministarstva nauke Republike Srbije, br. TR36008

  18. Instrumented roll technology for the design space development of roller compaction process.

    Science.gov (United States)

    Nesarikar, Vishwas V; Vatsaraj, Nipa; Patel, Chandrakant; Early, William; Pandey, Preetanshu; Sprockel, Omar; Gao, Zhihui; Jerzewski, Robert; Miller, Ronald; Levin, Michael

    2012-04-15

    Instrumented roll technology on Alexanderwerk WP120 roller compactor was developed and utilized successfully for the measurement of normal stress on ribbon during the process. The effects of process parameters such as roll speed (4-12 rpm), feed screw speed (19-53 rpm), and hydraulic roll pressure (40-70 bar) on normal stress and ribbon density were studied using placebo and active pre-blends. The placebo blend consisted of 1:1 ratio of microcrystalline cellulose PH102 and anhydrous lactose with sodium croscarmellose, colloidal silicon dioxide, and magnesium stearate. The active pre-blends were prepared using various combinations of one active ingredient (3-17%, w/w) and lubricant (0.1-0.9%, w/w) levels with remaining excipients same as placebo. Three force transducers (load cells) were installed linearly along the width of the roll, equidistant from each other with one transducer located in the center. Normal stress values recorded by side sensors and were lower than normal stress values recorded by middle sensor and showed greater variability than middle sensor. Normal stress was found to be directly proportional to hydraulic pressure and inversely to screw to roll speed ratio. For active pre-blends, normal stress was also a function of compressibility. For placebo pre-blends, ribbon density increased as normal stress increased. For active pre-blends, in addition to normal stress, ribbon density was also a function of gap. Models developed using placebo were found to predict ribbon densities of active blends with good accuracy and the prediction error decreased as the drug concentration of active blend decreased. Effective angle of internal friction and compressibility properties of active pre blend may be used as key indicators for predicting ribbon densities of active blend using placebo ribbon density model. Feasibility of on-line prediction of ribbon density during roller compaction was demonstrated using porosity-pressure data of pre-blend and normal stress

  19. Self-reported adherence rates in glaucoma patients in Southwest Nigeria

    Directory of Open Access Journals (Sweden)

    Adeola Olukorede Onakoya

    2016-01-01

    Full Text Available Context: Nigerian glaucoma patients have an aversion to surgery and often rely on medical therapy to prevent disease progression. For medical therapy to be effective, the drugs have to be used as prescribed. Compliance has been reported to be low in the previous Nigerian studies. Aims: To evaluate the adherence rates of primary open angle glaucoma (POAG patients on medical therapy using patient self-report. Settings and Design: A hospital-based cross-sectional design was used to assess consecutive POAG patients attending a glaucoma clinic in a Tertiary Hospital in Lagos, Nigeria. Subjects and Methods: Self-reported adherence was evaluated by trained interviewers. Comprehensive clinical assessment including intraocular pressure, gonioscopy, visual field assessment, and dilated binocular funduscopy using the slit lamp and + 78D fundus lens was done. Statistical Analysis Used: Data analysis was done using MedCalc Statistical Software. Results: One hundred and fourteen patients reported adherence rates ranging from 10% to 100% with a mean adherence rate of 82.33% ± 19.25%. Only 31 respondents (27.2% reported 100% adherence. Duration of the disease was the only significant factor on multiple regression analysis. Conclusions: The development of strategies to improve compliance and persistence in glaucoma patients is crucial for the reduction of disease progression and blindness.

  20. Study on deterministic response time design for a class of nuclear Instrumentation and Control systems

    International Nuclear Information System (INIS)

    Chen, Chang-Kuo; Hou, Yi-You; Luo, Cheng-Long

    2012-01-01

    Highlights: ► An efficient design procedure for deterministic response time design of nuclear I and C system. ► We model the concurrent operations based on sequence diagrams and Petri nets. ► The model can achieve the deterministic behavior by using symbolic time representation. ► An illustrative example of the bistable processor logic is given. - Abstract: This study is concerned with a deterministic response time design for computer-based systems in the nuclear industry. In current approach, Petri nets are used to model the requirement of a system specified with sequence diagrams. Also, the linear logic is proposed to characterize the state of changes in the Petri net model accurately by using symbolic time representation for the purpose of acquiring deterministic behavior. An illustrative example of the bistable processor logic is provided to demonstrate the practicability of the proposed approach.