WorldWideScience

Sample records for self-indication ratio measurements

  1. Comparison of measured and calculated 238U capture self-indication ratios from 4 to 10 keV

    International Nuclear Information System (INIS)

    Perez, R.B.; de Saussure, G.; Yang, J.T.; Munoz-Cobos, J.L.; Todd, J.H.

    1983-01-01

    From 4 keV to 149 keV the 238 U cross sections are represented in ENDF/B-V by unresolved-resonance parameters (URP). The purpose of this representation is to enable the calculation of resonance self-protection as a function of temperature and dilution. Since the URPs are not defined unambiguously by the cross-section data, it is important that the unresolved representation be tested with appropriate experiments, such as capture self-indication ratio (SIR) measurements. In this paper we compare 238 U capture SIR measurements in the 4- to 10-keV energy range with calculations done with ENDF/B-V and with recently published resolved resonance parameters

  2. Digit Ratio (2D:4D) Predicts Self-Reported Measures of General Competitiveness, but Not Behavior in Economic Experiments.

    Science.gov (United States)

    Bönte, Werner; Procher, Vivien D; Urbig, Diemo; Voracek, Martin

    2017-01-01

    The ratio of index finger length to ring finger length (2D:4D) is considered to be a putative biomarker of prenatal androgen exposure (PAE), with previous research suggesting that 2D:4D is associated with human behaviors, especially sex-typical behaviors. This study empirically examines the relationship between 2D:4D and individual competitiveness, a behavioral trait that is found to be sexually dimorphic. We employ two related, but distinct, measures of competitiveness, namely behavioral measures obtained from economic experiments and psychometric self-reported measures. Our analyses are based on two independent data sets obtained from surveys and economic experiments with 461 visitors of a shopping mall (Study I) and 617 university students (Study II). The correlation between behavior in the economic experiment and digit ratios of both hands is not statistically significant in either study. In contrast, we find a negative and statistically significant relationship between psychometric self-reported measures of competitiveness and right hand digit ratios (R2D:4D) in both studies. This relationship is especially strong for younger people. Hence, this study provides some robust empirical evidence for a negative association between R2D:4D and self-reported competitiveness. We discuss potential reasons why digit ratio may relate differently to behaviors in specific economics experiments and to self-reported general competitiveness.

  3. Digit Ratio (2D:4D Predicts Self-Reported Measures of General Competitiveness, but Not Behavior in Economic Experiments

    Directory of Open Access Journals (Sweden)

    Werner Bönte

    2017-12-01

    Full Text Available The ratio of index finger length to ring finger length (2D:4D is considered to be a putative biomarker of prenatal androgen exposure (PAE, with previous research suggesting that 2D:4D is associated with human behaviors, especially sex-typical behaviors. This study empirically examines the relationship between 2D:4D and individual competitiveness, a behavioral trait that is found to be sexually dimorphic. We employ two related, but distinct, measures of competitiveness, namely behavioral measures obtained from economic experiments and psychometric self-reported measures. Our analyses are based on two independent data sets obtained from surveys and economic experiments with 461 visitors of a shopping mall (Study I and 617 university students (Study II. The correlation between behavior in the economic experiment and digit ratios of both hands is not statistically significant in either study. In contrast, we find a negative and statistically significant relationship between psychometric self-reported measures of competitiveness and right hand digit ratios (R2D:4D in both studies. This relationship is especially strong for younger people. Hence, this study provides some robust empirical evidence for a negative association between R2D:4D and self-reported competitiveness. We discuss potential reasons why digit ratio may relate differently to behaviors in specific economics experiments and to self-reported general competitiveness.

  4. Measuring Poisson Ratios at Low Temperatures

    Science.gov (United States)

    Boozon, R. S.; Shepic, J. A.

    1987-01-01

    Simple extensometer ring measures bulges of specimens in compression. New method of measuring Poisson's ratio used on brittle ceramic materials at cryogenic temperatures. Extensometer ring encircles cylindrical specimen. Four strain gauges connected in fully active Wheatstone bridge self-temperature-compensating. Used at temperatures as low as liquid helium.

  5. Characteristic Determination Of Self Shielding Factor And Cadmium Ratio Of Cylindrical Probe

    International Nuclear Information System (INIS)

    Hamzah, Amir; Budi R, Ita; Pinem, Suriam

    1996-01-01

    Determination of thermal, epithermal and total self shielding factor and cadmium ratio of cylindrical probe has been done by measurement and calculation. Self shielding factor can be determined by dividing probe activity to Al-alloy probe activity. Due to the lack of cylindrical probe made of Al-alloy, self shielding factor can be determined by parabolic extrapolation of measured activities to 0 cm radius to divide those activities. Theoretically, self shielding factor can be determined by making numerical solution of two dimensional integral equations using Romberg method. To simplify, the calculation is based on single collision theory with the assumption of monoenergetic neutron and isotropic distribution. For gold cylindrical probe, the calculation results are quite close to the measurement one with the relative discrepancy for activities, cadmium ratio and self shielding factor of bare probe are less then 11.5%, 3,5% and 1.5% respectively. The program can be used for the calculation of other kinds of cylindrical probes. Due to dependency to radius, cylindrical probe made of copper has the best characteristic of self shielding factor and cadmium ratio

  6. URR [Unresolved Resonance Region] computer code: A code to calculate resonance neutron cross-section probability tables, Bondarenko self-shielding factors, and self-indication ratios for fissile and fertile nuclides

    International Nuclear Information System (INIS)

    Leal, L.C.; de Saussure, G.; Perez, R.B.

    1990-01-01

    The URR computer code has been developed to calculate cross-section probability tables, Bondarenko self-shielding factors, and self-indication ratios for fertile and fissile isotopes in the unresolved resonance region. Monte Carlo methods are utilized to select appropriate resonance parameters and to compute the cross sections at the desired reference energy. The neutron cross sections are calculated by the single-level Breit-Wigner formalism with s-, p-, and d-wave contributions. The cross-section probability tables are constructed by sampling by Doppler broadened cross-sections. The various self-shielding factors are computer numerically as Lebesgue integrals over the cross-section probability tables

  7. Evaluating signal-to-noise ratios, loudness, and related measures as indicators of airborne sound insulation.

    Science.gov (United States)

    Park, H K; Bradley, J S

    2009-09-01

    Subjective ratings of the audibility, annoyance, and loudness of music and speech sounds transmitted through 20 different simulated walls were used to identify better single number ratings of airborne sound insulation. The first part of this research considered standard measures such as the sound transmission class the weighted sound reduction index (R(w)) and variations of these measures [H. K. Park and J. S. Bradley, J. Acoust. Soc. Am. 126, 208-219 (2009)]. This paper considers a number of other measures including signal-to-noise ratios related to the intelligibility of speech and measures related to the loudness of sounds. An exploration of the importance of the included frequencies showed that the optimum ranges of included frequencies were different for speech and music sounds. Measures related to speech intelligibility were useful indicators of responses to speech sounds but were not as successful for music sounds. A-weighted level differences, signal-to-noise ratios and an A-weighted sound transmission loss measure were good predictors of responses when the included frequencies were optimized for each type of sound. The addition of new spectrum adaptation terms to R(w) values were found to be the most practical approach for achieving more accurate predictions of subjective ratings of transmitted speech and music sounds.

  8. The ATP/DNA Ratio Is a Better Indicator of Islet Cell Viability Than the ADP/ATP Ratio

    Science.gov (United States)

    Suszynski, T.M.; Wildey, G.M.; Falde, E.J.; Cline, G.W.; Maynard, K. Stewart; Ko, N.; Sotiris, J.; Naji, A.; Hering, B.J.; Papas, K.K.

    2009-01-01

    Real-time, accurate assessment of islet viability is critical for avoiding transplantation of nontherapeutic preparations. Measurements of the intracellular ADP/ATP ratio have been recently proposed as useful prospective estimates of islet cell viability and potency. However, dead cells may be rapidly depleted of both ATP and ADP, which would render the ratio incapable of accounting for dead cells. Since the DNA of dead cells is expected to remain stable over prolonged periods of time (days), we hypothesized that use of the ATP/DNA ratio would take into account dead cells and may be a better indicator of islet cell viability than the ADP/ATP ratio. We tested this hypothesis using mixtures of healthy and lethally heat-treated (HT) rat insulinoma cells and human islets. Measurements of ATP/DNA and ADP/ATP from the known mixtures of healthy and HT cells and islets were used to evaluate how well these parameters correlated with viability. The results indicated that ATP and ADP were rapidly (within 1 hour) depleted in HT cells. The fraction of HT cells in a mixture correlated linearly with the ATP/DNA ratio, whereas the ADP/ADP ratio was highly scattered, remaining effectively unchanged. Despite similar limitations in both ADP/ADP and ATP/DNA ratios, in that ATP levels may fluctuate significantly and reversibly with metabolic stress, the results indicated that ATP/DNA was a better measure of islet viability than the ADP/ATP ratio. PMID:18374063

  9. Relationship of self-management to personality types and indices.

    Science.gov (United States)

    Williams, R L; Verble, J S; Price, D E; Layne, B H

    1995-06-01

    This study addressed the relationship between self-management (as measured by the Lifestyle Approaches Inventory, Williams, Moore, Pettibone, & Thomas, 1992) and personality types and indexes (as measured by the Myers-Briggs Type Indicator, Myers & McCaulley, 1985) in a sample of 347 university students. Correlational analyses indicated that the self-management factor most consistently linked to the Myers-Briggs indices was Organization of Physical Space. The Myers-Briggs index most consistently correlated with the self-management factors was Judgment-Perception. Overall, male and female subjects showed similar patterns of relationships between the self-management and personality indices. When the self-management scores were compared for the various Myers-Briggs types, the analysis indicated that types having a J (planful and organized) or S (precise and practical) in the typology tended to score higher than those having a P (spontaneous and flexible) or N (imaginative and insightful).

  10. Ratios performance indicator evaluation of selected engineering enterprises in the northeast cohesion region

    OpenAIRE

    Šenec, Alexandr

    2014-01-01

    The paper deals with the performance indicator evaluation of selected industrial companies with a predominance of engineering production. Ratio indicators were used in order to measure business performance per unit of fixed assets and per employee. Analyzed data were obtained from companies annual reports. Trends ratio indicators were intended with the help of mathematical and statistical methods. These ratios indicator assessing the level of performance, value added and operating profit p...

  11. URR [Unresolved Resonance Region] computer code: A code to calculate resonance neutron cross-section probability tables, Bondarenko self-shielding factors, and self-indication ratios for fissile and fertile nuclides

    International Nuclear Information System (INIS)

    Leal, L.C.; de Saussure, G.; Perez, R.B.

    1989-01-01

    The URR computer code has been developed to calculate cross-section probability tables, Bondarenko self-shielding factors, and self- indication ratios for fertile and fissile isotopes in the unresolved resonance region. Monte Carlo methods are utilized to select appropriate resonance parameters and to compute the cross sections at the desired reference energy. The neutron cross sections are calculated by the single-level Breit-Wigner formalism with s-, p-, and d-wave contributions. The cross-section probability tables are constructed by sampling the Doppler broadened cross-section. The various shelf-shielded factors are computed numerically as Lebesgue integrals over the cross-section probability tables. 6 refs

  12. Balanced detection for self-mixing interferometry to improve signal-to-noise ratio

    Science.gov (United States)

    Zhao, Changming; Norgia, Michele; Li, Kun

    2018-01-01

    We apply balanced detection to self-mixing interferometry for displacement and vibration measurement, using two photodiodes for implementing a differential acquisition. The method is based on the phase opposition of the self-mixing signal measured between the two laser diode facet outputs. The balanced signal obtained by enlarging the self-mixing signal, also by canceling of the common-due noises mainly due to disturbances on laser supply and transimpedance amplifier. Experimental results demonstrate the signal-to-noise ratio significantly improves, with almost twice signals enhancement and more than half noise decreasing. This method allows for more robust, longer-distance measurement systems, especially using fringe-counting.

  13. RNA:DNA Ratio and Other Nucleic Acid Derived Indices in Marine Ecology

    Directory of Open Access Journals (Sweden)

    Luis Chícharo

    2008-08-01

    Full Text Available Some of most used indicators in marine ecology are nucleic acid-derived indices. They can be divided by target levels in three groups: 1 at the organism level as ecophysiologic indicators, indicators such as RNA:DNA ratios, DNA:dry weight and RNA:protein, 2 at the population level, indicators such as growth rate, starvation incidence or fisheries impact indicators, and 3 at the community level, indicators such as trophic interactions, exergy indices and prey identification. The nucleic acids derived indices, especially RNA:DNA ratio, have been applied with success as indicators of nutritional condition, well been and growth in marine organisms. They are also useful as indicators of natural or anthropogenic impacts in marine population and communities, such as upwelling or dredge fisheries, respectively. They can help in understanding important issues of marine ecology such as trophic interactions in marine environment, fish and invertebrate recruitment failure and biodiversity changes, without laborious work of counting, measuring and identification of small marine organisms. Besides the objective of integrate nucleic acid derived indices across levels of organization, the paper will also include a general characterization of most used nucleic acid derived indices in marine ecology and also advantages and limitations of them. We can conclude that using indicators, such RNA:DNA ratios and other nucleic acids derived indices concomitantly with organism and ecosystems measures of responses to climate change (distribution, abundance, activity, metabolic rate, survival will allow for the development of more rigorous and realistic predictions of the effects of anthropogenic climate change on marine systems.

  14. The association between self-rated health and different anthropometric and body composition measures in the Chinese population

    Directory of Open Access Journals (Sweden)

    Kun Tang

    2017-04-01

    Full Text Available Abstract Background To analyze the strength of association between self-rated health and six anthropometric and body composition measures to explore the best indicator. Methods Analyses were based on the cross-sectional data from the China Kadoorie Biobank Study and approximately 300,000 adults were analyzed. Logistics regression was used to analyze the association between self-rated health (good or poor and anthropometric and body composition measures (height, weight, body mass index (BMI, waist circumference (WC, hip circumference (HC and body fat percentage, waist-to-hip ratio and waist-to-height ratio. Stratified analyses were undertaken to understand the effect modification of socioeconomic status on the association. Result Odds ratio of self-rated better health had an inverted U-shape association with weight, BMI, WC and body fat, with weight levels increasing until around 73.8 and 65.7 kg for male and female, BMI around 26.8 kg/m2, WC around 85.8 and 87.6 cm, body fat around 24.3 and 36.3%, and then declining thereafter. Height and HC also indicated a slightly inverted U-shape association. The strongest association was observed after adjustment was weight, with one standard deviation greater weight associated with 10.2% and 10.6% increased odds in male and female. Conclusions Being underweight and overweight are both risk factors for poor self-rated health in males and females, and weight is the best indicator of self-rated health compared with other measures.

  15. Social desirability scales as indicators of self-enhancement and impression management.

    Science.gov (United States)

    Parmač Kovačić, Maja; Galić, Zvonimir; Jerneić, Željko

    2014-01-01

    This article presents 2 studies testing Paulhus's (2002) assumption that unconscious self-enhancement and conscious impression management represent separate processes of socially desirable responding (SDR) that can be observed within 2 content domains (egoistic and moralistic bias). In Study 1, we devised egoistic and moralistic SDR scales intended to measure self-enhancement in honest responding and impression management under demands for positive self-presentation. In Study 2, we correlated scores on these scales with external indicators of self-enhancement and impression management. In honest responding, both SDR scales most strongly correlated with self-enhancement indicators, whereas under demands for positive self-presentation they correlated more strongly with external measures of impression management.

  16. International normalized ratio self-testing and self-management: improving patient outcomes

    Directory of Open Access Journals (Sweden)

    Pozzi M

    2016-10-01

    Full Text Available Matteo Pozzi,1 Julia Mitchell,2 Anna Maria Henaine,3 Najib Hanna,4 Ola Safi,4 Roland Henaine2 1Department of Adult Cardiac Surgery, “Louis Pradel” Cardiologic Hospital, Lyon, France; 2Department of Congenital Cardiac Surgery, “Louis Pradel” Cardiologic Hospital, Lyon, France; 3Clinical Pharmacology Unit, Lebanese University, Beirut, Lebanon; 4Pediatric Unit, “Hotel Dieu de France” Hospital, Saint Joseph University, Beirut, Lebanon Abstract: Long term oral anti-coagulation with vitamin K antagonists is a risk factor of hemorrhagic or thromebomlic complications. Periodic laboratory testing of international normalized ratio (INR and a subsequent dose adjustment are therefore mandatory. The use of home testing devices to measure INR has been suggested as a potential way to improve the comfort and compliance of the patients and their families, the frequency of monitoring and, finally, the management and safety of long-term oral anticoagulation. In pediatric patients, increased doses to obtain and maintain the therapeutic target INR, more frequent adjustments and INR testing, multiple medication, inconstant nutritional intake, difficult venepunctures, and the need to go to the laboratory for testing (interruption of school and parents’ work attendance highlight those difficulties. After reviewing the most relevant published studies of self-testing and self-management of INR for adult patients and children on oral anticoagulation, it seems that these are valuable and effective strategies of INR control. Despite an unclear relationship between INR control and clinical effects, these self-strategies provide a better control of the anticoagulant effect, improve patients and their family quality of life, and are an appealing solution in term of cost-effectiveness. Structured education and knowledge evaluation by trained health care professionals is required for children, to be able to adjust their dose treatment safely and accurately. However

  17. Effectiveness of a Self-monitoring Device for Urinary Sodium-to-Potassium Ratio on Dietary Improvement in Free-Living Adults: a Randomized Controlled Trial.

    Science.gov (United States)

    Iwahori, Toshiyuki; Ueshima, Hirotsugu; Ohgami, Naoto; Yamashita, Hideyuki; Miyagawa, Naoko; Kondo, Keiko; Torii, Sayuki; Yoshita, Katsushi; Shiga, Toshikazu; Ohkubo, Takayoshi; Arima, Hisatomi; Miura, Katsuyuki

    2018-01-05

    Reducing the urinary sodium-to-potassium ratio is important for reducing both blood pressure and risk of cardiovascular disease. Among free-living Japanese individuals, we carried out a randomized trial to clarify the effect of lifestyle modification for lowering urinary sodium-to-potassium ratio using a self-monitoring device. This was an open, prospective, parallel randomized, controlled trial. Ninety-two individuals were recruited from Japanese volunteers. Participants were randomly allocated into intervention and control groups. A month-long dietary intervention on self-monitoring urinary sodium-to-potassium ratio was carried out using monitors (HEU-001F, OMRON Healthcare Co., Ltd., Kyoto, Japan). All participants had brief dietary education and received a leaflet as usual care. Monitors were handed out to the intervention group, but not to the control group. The intervention group was asked to measure at least one spot urine sodium-to-potassium ratio daily, and advised to lower their sodium-to-potassium ratio toward the target of less than 1. Outcomes included changes in 24-hour urinary sodium-to-potassium ratio, sodium excretion, potassium excretion, blood pressure, and body weight in both groups. Mean measurement frequency of monitoring was 2.8 times/day during the intervention. Changes in urinary sodium-to-potassium ratio were -0.55 in the intervention group and -0.06 in the control group (P = 0.088); respective sodium excretion changes were -18.5 mmol/24 hours and -8.7 mmol/24 hours (P = 0.528); and corresponding potassium excretion was 2.6 mmol/24 hours and -1.5 mmol/24 hours (P = 0.300). No significant reductions were observed in either blood pressure or body weight after the intervention. Providing the device to self-monitor a sodium-to-potassium ratio did not achieve the targeted reduction of the ratio in "pure self-management" settings, indicating further needs to study an effective method to enhance the synergetic effect of dietary programs and self

  18. Facial Width-to-Height Ratio Does Not Predict Self-Reported Behavioral Tendencies.

    Science.gov (United States)

    Kosinski, Michal

    2017-11-01

    A growing number of studies have linked facial width-to-height ratio (fWHR) with various antisocial or violent behavioral tendencies. However, those studies have predominantly been laboratory based and low powered. This work reexamined the links between fWHR and behavioral tendencies in a large sample of 137,163 participants. Behavioral tendencies were measured using 55 well-established psychometric scales, including self-report scales measuring intelligence, domains and facets of the five-factor model of personality, impulsiveness, sense of fairness, sensational interests, self-monitoring, impression management, and satisfaction with life. The findings revealed that fWHR is not substantially linked with any of these self-reported measures of behavioral tendencies, calling into question whether the links between fWHR and behavior generalize beyond the small samples and specific experimental settings that have been used in past fWHR research.

  19. Effectiveness of a Self-monitoring Device for Urinary Sodium-to-Potassium Ratio on Dietary Improvement in Free-Living Adults: a Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Toshiyuki Iwahori

    2018-01-01

    Full Text Available Background: Reducing the urinary sodium-to-potassium ratio is important for reducing both blood pressure and risk of cardiovascular disease. Among free-living Japanese individuals, we carried out a randomized trial to clarify the effect of lifestyle modification for lowering urinary sodium-to-potassium ratio using a self-monitoring device. Methods: This was an open, prospective, parallel randomized, controlled trial. Ninety-two individuals were recruited from Japanese volunteers. Participants were randomly allocated into intervention and control groups. A month-long dietary intervention on self-monitoring urinary sodium-to-potassium ratio was carried out using monitors (HEU-001F, OMRON Healthcare Co., Ltd., Kyoto, Japan. All participants had brief dietary education and received a leaflet as usual care. Monitors were handed out to the intervention group, but not to the control group. The intervention group was asked to measure at least one spot urine sodium-to-potassium ratio daily, and advised to lower their sodium-to-potassium ratio toward the target of less than 1. Outcomes included changes in 24-hour urinary sodium-to-potassium ratio, sodium excretion, potassium excretion, blood pressure, and body weight in both groups. Results: Mean measurement frequency of monitoring was 2.8 times/day during the intervention. Changes in urinary sodium-to-potassium ratio were −0.55 in the intervention group and −0.06 in the control group (P = 0.088; respective sodium excretion changes were −18.5 mmol/24 hours and −8.7 mmol/24 hours (P = 0.528; and corresponding potassium excretion was 2.6 mmol/24 hours and −1.5 mmol/24 hours (P = 0.300. No significant reductions were observed in either blood pressure or body weight after the intervention. Conclusions: Providing the device to self-monitor a sodium-to-potassium ratio did not achieve the targeted reduction of the ratio in “pure self-management” settings, indicating further needs to study an

  20. Analysis of academic performance management indicators of IFES

    Directory of Open Access Journals (Sweden)

    Fátima de Souza Freire

    2008-07-01

    self interest with their own training, as measured by their success ratio and greater dedication to their under graduate course. In the same direction there has been found a favourable effect of the number of students-workers ratio. Nevertheless, no positive effect of the costs per student ratio has been detected as expected, considering the desirable positive influence of such indicator in the quality of education. Key-words: Performance Indicators, Enade, IFES.

  1. Self-indicating radiation alert dosemeter (SIRAD)

    International Nuclear Information System (INIS)

    Riel, G. K.; Winters, P.; Patel, G.; Patel, P.

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident. (authors)

  2. Self-indicating radiation alert dosemeter (SIRAD).

    Science.gov (United States)

    Riel, Gordon K; Winters, Patrick; Patel, Gordhan; Patel, Paresh

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by 3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident.

  3. Facial Width-to-Height Ratio Does Not Predict Self-Reported Behavioral Tendencies

    OpenAIRE

    Kosinski, Michal

    2017-01-01

    A growing number of studies have linked facial width-to-height ratio (fWHR) with various antisocial or violent behavioral tendencies. However, those studies have predominantly been laboratory based and low powered. This work reexamined the links between fWHR and behavioral tendencies in a large sample of 137,163 participants. Behavioral tendencies were measured using 55 well-established psychometric scales, including self-report scales measuring intelligence, domains and facets of the five-fa...

  4. The value of pulmonary vessel CT measuring and calculating of relative ratio

    International Nuclear Information System (INIS)

    Ji Jiansong; Xu Xiaoxiong; Lv Suzhen; Zhao Zhongwei; Wang Zufei; Xu Min; Gong Jianping

    2004-01-01

    Objective: To evaluate value of CT measurement and calculation of vessels of isolate pig lung, by compare with measurement and calculation of resin cast of them. Methods: CT scanned and measured the four isolated pig lung which vessels were full with ABS liquid or self-solidification resin liquid, and calculate the relative ratio of superior/inferior order and vein/artery of same order. After resin cast were made, measure and calculate the same as CT did. Results: Second order of calculation of vein/artery of same order by the two method had statistic difference (P 0.05). Conclusion: CT has high value in calculation of the relative ratio of superior/inferior order

  5. Radiographic measurement of the cardiothoracic ratio in pet macaques from Sulawesi, Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Michael A. [Department of Social Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4 (Canada)], E-mail: schillaci@utsc.utoronto.ca; Parish, Stephanie [Department of Social Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4 (Canada); Jones-Engel, Lisa [National Primate Research Center, University of Washington, 1705 N.E. Pacific Street, Seattle, WA 98195 (United States)

    2009-11-15

    The relative size of the heart, as measured by the cardiothoracic ratio, is often used as an index of ventricular hypertrophy-an important measure of myocardial pathophysiology in human primates. Despite its widespread use in human medicine, use of the cardiothoracic ratio in nonhuman primate veterinary medicine has been poorly documented. This report describes the results of our radiographic study of the cardiothoracic ratio in a sample of pet monkeys from Sulawesi, Indonesia. We assessed the effects of age and sex on cardiothoracic ratios, and compared our estimates with those presented in the literature for the Formosan macaque (Macaca cyclopis). Our results indicated a significant difference between the Sulawesi macaque species groupings in cardiothoracic ratios. Sex and age-related differences were not significant. Comparisons of cardiothoracic ratios with published ratios indicated similarity between M. cyclopis and Macaca nigra, but not between M. cyclopis and Macaca tonkeana.

  6. Radiographic measurement of the cardiothoracic ratio in pet macaques from Sulawesi, Indonesia

    International Nuclear Information System (INIS)

    Schillaci, Michael A.; Parish, Stephanie; Jones-Engel, Lisa

    2009-01-01

    The relative size of the heart, as measured by the cardiothoracic ratio, is often used as an index of ventricular hypertrophy-an important measure of myocardial pathophysiology in human primates. Despite its widespread use in human medicine, use of the cardiothoracic ratio in nonhuman primate veterinary medicine has been poorly documented. This report describes the results of our radiographic study of the cardiothoracic ratio in a sample of pet monkeys from Sulawesi, Indonesia. We assessed the effects of age and sex on cardiothoracic ratios, and compared our estimates with those presented in the literature for the Formosan macaque (Macaca cyclopis). Our results indicated a significant difference between the Sulawesi macaque species groupings in cardiothoracic ratios. Sex and age-related differences were not significant. Comparisons of cardiothoracic ratios with published ratios indicated similarity between M. cyclopis and Macaca nigra, but not between M. cyclopis and Macaca tonkeana.

  7. Measurement of the anisotropy ratios in MgB2 single crystals

    International Nuclear Information System (INIS)

    Kim, Heon-Jung; Kang, Byeongwon; Lee, Hyun-Sook; Lee, Sung-Ik

    2006-01-01

    We present our recent measurements on the anisotropy ratios of MgB 2 single crystals. Our measurements indicate that the anisotropy ratios of the penetration depth and of the upper critical field have different magnitudes and temperature dependences, as predicted by theoretical calculations. These results imply that the two-gap nature can strongly influence the superconducting properties of MgB 2

  8. Nondestructive measurement of the grid ratio using a single image

    International Nuclear Information System (INIS)

    Pasciak, A. S.; Jones, A. Kyle

    2009-01-01

    The antiscatter grid is an essential part of modern radiographic systems. Since the introduction of the antiscatter grid, however, there have been few methods proposed for acceptance testing and verification of manufacturer-supplied grid specifications. The grid ratio (r) is an important parameter describing the antiscatter grid because it affects many other grid quality metrics, such as the contrast improvement ratio (K), primary transmission (T p ), and scatter transmission (T s ). Also, the grid ratio in large part determines the primary clinical use of the grid. To this end, the authors present a technique for the nondestructive measurement of the grid ratio of antiscatter grids. They derived an equation that can be used to calculate the grid ratio from a single off-focus flat field image by exploiting the relationship between grid cutoff and off-focus distance. The calculation can be performed by hand or with included analysis software. They calculated the grid ratios of several different grids throughout the institution, and afterward they destructively measured the grid ratio of a nominal r8 grid previously evaluated with the method. They also studied the sensitivity of the method to technical factors and choice of parameters. With one exception, the results for the grids found in the institution were in agreement with the manufacturer's specifications and international standards. The nondestructive evaluation of the r8 grid indicated a ratio of 7.3, while the destructive measurement indicated a ratio of 7.53±0.28. Repeated evaluations of the same grid yielded consistent results. The technique provides the medical physicist with a new tool for quantitative evaluation of the grid ratio, an important grid performance criterion. The method is robust and repeatable when appropriate choices of technical factors and other parameters are made.

  9. Stable isotope ratio measurements in hydrogen, nitrogen, and oxygen using Raman scattering

    International Nuclear Information System (INIS)

    Harney, R.C.; Bloom, S.D.; Milanovich, F.P.

    1975-01-01

    A method for measuring stable isotope ratios using laser Raman scattering was developed which may prove of significant utility and benefit in stable isotope tracer studies. Crude isotope ratio measurements obtained with a low-power laser indicate that with current technology it should be possible to construct an isotope ratio measurement system using laser Raman scattering that is capable of performing 0.1 percent accuracy isotope ratio measurements of 16 O/ 18 O in natural abundance oxygen gas or 14 N/ 15 N in natural abundance nitrogen gas in times less than two minutes per sample. Theory pertinent to the technique, designs of specific isotope ratio spectrometer systems, and data relating to isotope ratio measurements in hydrogen, nitrogen, and oxygen are presented. In addition, the current status of several studies utilizing this technique is discussed. (auth)

  10. International normalized ratio self-management lowers the risk of thromboembolic events after prosthetic heart valve replacement.

    Science.gov (United States)

    Eitz, Thomas; Schenk, Soren; Fritzsche, Dirk; Bairaktaris, Andreas; Wagner, Otto; Koertke, Heinrich; Koerfer, Reiner

    2008-03-01

    Although prosthetic valves are durable and easy to implant, the need for lifetime warfarin-based anticoagulation restricts their exclusive usage. We investigated if anticoagulation self-management improves outcome in a single-center series. Between 1994 and 1998, 765 patients with prosthetic valve replacements were prospectively enrolled and randomized to receive conventional anticoagulation management by their primary physician (group 1, n = 295) or to pursue anticoagulation self-management (group 2, n = 470). A study head office was implemented to coordinate and monitor anticoagulation protocols, international normalized ratios (INR), and adverse events. Patients were instructed on how to obtain and test their own blood samples and to adjust warfarin dosages according to the measured INR (target range, 2.5 to 4). Mean INR values were slightly yet significantly smaller in group 1 than in group 2 (2.8 +/- 0.7 vs 3.0 +/- .6, p events were similar in both groups. Time-related multivariate analysis identified INR self-management and higher INR as independent predictors for better outcome. Anticoagulation self-management can improve INR profiles up to 2 years after prosthetic valve replacement and reduce adverse events. Current indications of prosthetic rather than biologic valve implantations may be extended if the benefit of INR self-management is shown by future studies with longer follow-up.

  11. Measurement of cell volume changes by fluorescence self-quenching

    DEFF Research Database (Denmark)

    Hamann, Steffen; Kiilgaard, J.F.; Litman, Thomas

    2002-01-01

    At high concentrations, certain fluorophores undergo self-quenching, i.e., fluorescence intensity decreases with increasing fluorophore concentration. Accordingly, the self-quenching properties can be used for measuring water volume changes in lipid vesicles. In cells, quantitative determination...... concentrations of the fluorophore calcein suitable for measurement of changes in cell water volume by self-quenching. The relationship between calcein fluorescence intensity, when excited at 490 nm (its excitation maximum), and calcein concentration was investigated in vitro and in various cultured cell types...... to a decrease in calcein fluorescence with high signal-to-noise ratio (>15). Similar results were obtained with the fluorophore BCECF when excited at its isosbestic wavelength (436 nm). The present results demonstrate the usefulness of fluorescence self-quenching to measure rapid changes in cell water volume....

  12. Waist-to-Height Ratio as an Indicator of High Blood Pressure in Urban Indian School Children.

    Science.gov (United States)

    Mishra, P E; Shastri, L; Thomas, T; Duggan, C; Bosch, R; McDonald, C M; Kurpad, A V; Kuriyan, R

    2015-09-01

    To examine the utility of waist-to-height ratio to identify risk of high blood pressure when compared to body mass index and waist circumference in South Indian urban school children. Secondary data analysis from a cross-sectional study. Urban schools around Bangalore, India. 1913 children (58.1% males) aged 6-16 years with no prior history of chronic illness (PEACH study). Height, weight, waist circumference and of blood pressure were measured. Children with blood pressure ?90th percentile of age-, sex-, and height-adjusted standards were labelled as having high blood pressure. 13.9% had a high waist-to-height ratio, 15.1% were overweight /obese and 21.7% had high waist circumference. High obesity indicators were associated with an increased risk of high blood pressure. The adjusted risk ratios (95% CI) of high systolic blood pressure with waist-to-height ratio, body mass index and waist circumference were 2.48 (1.76, 3.47), 2.59 (1.66, 4.04) and 2.38 (1.74, 3.26), respectively. Similar results were seen with high diastolic blood pressure. Obesity indicators, especially waist-to-height ratio due to its ease of measurement, can be useful initial screening tools for risk of high blood pressure in urban Indian school children.

  13. Fructose:glucose ratios--a study of sugar self-administration and associated neural and physiological responses in the rat.

    Science.gov (United States)

    Levy, AnneMarie; Marshall, Paul; Zhou, Yan; Kreek, Mary Jeanne; Kent, Katrina; Daniels, Stephen; Shore, Ari; Downs, Tiana; Fernandes, Maria Fernanda; Mutch, David M; Leri, Francesco

    2015-05-22

    This study explored whether different ratios of fructose (F) and glucose (G) in sugar can engender significant differences in self-administration and associated neurobiological and physiological responses in male Sprague-Dawley rats. In Experiment 1, animals self-administered pellets containing 55% F + 45% G or 30% F + 70% G, and Fos immunoreactivity was assessed in hypothalamic regions regulating food intake and reward. In Experiment 2, rats self-administered solutions of 55% F + 42% G (high fructose corn syrup (HFCS)), 50% F + 50% G (sucrose) or saccharin, and mRNA of the dopamine 2 (D2R) and mu-opioid (MOR) receptor genes were assessed in striatal regions involved in addictive behaviors. Finally, in Experiment 3, rats self-administered HFCS and sucrose in their home cages, and hepatic fatty acids were quantified. It was found that higher fructose ratios engendered lower self-administration, lower Fos expression in the lateral hypothalamus/arcuate nucleus, reduced D2R and increased MOR mRNA in the dorsal striatum and nucleus accumbens core, respectively, as well as elevated omega-6 polyunsaturated fatty acids in the liver. These data indicate that a higher ratio of fructose may enhance the reinforcing effects of sugar and possibly lead to neurobiological and physiological alterations associated with addictive and metabolic disorders.

  14. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  15. Measuring occupational stress: development of the pressure management indicator.

    Science.gov (United States)

    Williams, S; Cooper, C L

    1998-10-01

    The study of occupational stress is hindered by the lack of compact and comprehensive standardized measurement tools. The Pressure Management Indicator (PMI) is a 120-item self-report questionnaire developed from the Occupational Stress Indicator (OSI). The PMI is more reliable, more comprehensive, and shorter than the OSI. It provides an integrated measure of the major dimensions of occupational stress. The outcome scales measure job satisfaction, organizational satisfaction, organizational security, organizational commitment, anxiety--depression, resilience, worry, physical symptoms, and exhaustion. The stressor scales cover pressure from workload, relationships, career development, managerial responsibility, personal responsibility, home demands, and daily hassles. The moderator variables measure drive, impatience, control, decision latitude, and the coping strategies of problem focus, life work balance, and social support.

  16. Graphite Isotope Ratio Method Development Report: Irradiation Test Demonstration of Uranium as a Low Fluence Indicator

    International Nuclear Information System (INIS)

    Reid, B.D.; Gerlach, D.C.; Love, E.F.; McNeece, J.P.; Livingston, J.V.; Greenwood, L.R.; Petersen, S.L.; Morgan, W.C.

    1999-01-01

    This report describes an irradiation test designed to investigate the suitability of uranium as a graphite isotope ratio method (GIRM) low fluence indicator. GIRM is a demonstrated concept that gives a graphite-moderated reactor's lifetime production based on measuring changes in the isotopic ratio of elements known to exist in trace quantities within reactor-grade graphite. Appendix I of this report provides a tutorial on the GIRM concept

  17. Isotope ratios of lead as pollutant source indicators

    International Nuclear Information System (INIS)

    Chow, T.J.; Snyder, C.B.; Earal, J.L.

    1975-01-01

    Each lead ore deposit has its characteristic isotope ratios which are fixed during mineral ore genesis, and this unique property can be used to indicate the source of lead pollutants in the environment. The wolld production of primary lead is tabulated, and the geochemical significances of lead isotope ratios are discussed. The manufacture of lead alkyl additives for gasoline, which is the major source of lead pollutants, utilizes about 10% of the world annual consumption of lead. The isotope ratios of lead in gasoline, aerosols, soils and plants are correlated. Lead additives in various brands of gasoline sold in one region do not have the same isotope ratios. Regional variations in isotope ratios of lead additives were observed. This reflects the fact that petroleum refineries obtained the additives from various lead alkyl manufacturers which utilized lead from different mining districts. A definite changing trend of isotope ratios of lead pollutants in the San Diego, California (USA), area was detected. The lead shows a gradual increase in its radiogenic components during the past decade. This trend can be explained by the change of lead sources used by the additive manufacturers: Lead isotope ratios of the mid-1960's gasoline additives in the United States of America reflected those of less radiogenic leads imported from Canada, Australia, Peru and Mexico. Since then, the U.S. lead production has doubled-mainly from the Missouri district of highly radiogenic lead. Meanwhile, there has been a decrease in total lead imports. These combined effects result in changes in isotope ratios, from the less to more radiogenic, of the pooled lead. (aothor)

  18. From Excessive Journal Self-Cites to Citation Stacking: Analysis of Journal Self-Citation Kinetics in Search for Journals, Which Boost Their Scientometric Indicators.

    Science.gov (United States)

    Heneberg, Petr

    2016-01-01

    Bibliometric indicators increasingly affect careers, funding, and reputation of individuals, their institutions and journals themselves. In contrast to author self-citations, little is known about kinetics of journal self-citations. Here we hypothesized that they may show a generalizable pattern within particular research fields or across multiple fields. We thus analyzed self-cites to 60 journals from three research fields (multidisciplinary sciences, parasitology, and information science). We also hypothesized that the kinetics of journal self-citations and citations received from other journals of the same publisher may differ from foreign citations. We analyzed the journals published the American Association for the Advancement of Science, Nature Publishing Group, and Editura Academiei Române. We found that although the kinetics of journal self-cites is generally faster compared to foreign cites, it shows some field-specific characteristics. Particularly in information science journals, the initial increase in a share of journal self-citations during post-publication year 0 was completely absent. Self-promoting journal self-citations of top-tier journals have rather indirect but negligible direct effects on bibliometric indicators, affecting just the immediacy index and marginally increasing the impact factor itself as long as the affected journals are well established in their fields. In contrast, other forms of journal self-citations and citation stacking may severely affect the impact factor, or other citation-based indices. We identified here a network consisting of three Romanian physics journals Proceedings of the Romanian Academy, Series A, Romanian Journal of Physics, and Romanian Reports in Physics, which displayed low to moderate ratio of journal self-citations, but which multiplied recently their impact factors, and were mutually responsible for 55.9%, 64.7% and 63.3% of citations within the impact factor calculation window to the three journals

  19. Human figure drawings and house tree person drawings as indicators of self-esteem: a quantitative approach.

    Science.gov (United States)

    Groth-Marnat, G; Roberts, L

    1998-02-01

    This study assessed the concurrent validity of Human Figure Drawings (HFD) and House-Tree-Person (HTP) drawings as measures of self-esteem. Adult subjects were requested to make HFD and HTP drawings and to complete measures of psychological adjustment which included the Coopersmith Self Esteem Inventory and Tennessee Self Concept Scale. The drawings were scored using a quantitative, composite rating scale derived from HFD and HTP empirical and theoretical literature on psychological health. Results indicated that neither the HFD nor the HTP quantitative composite ratings of psychological health related to the formal measures of self-esteem.

  20. Business sustainability performance measurement: Eco-ratio analysis

    Directory of Open Access Journals (Sweden)

    Collins C. Ngwakwe

    2016-12-01

    Full Text Available Eco-aware customers and stakeholders are demanding for a measurement that links environmental performance with other business operations. To bridge this seemingly measurement gap, this paper suggests ‘Eco-Ratio Analysis’ and proposes an approach for conducting eco-ratio analysis. It is argued that since accounting ratios function as a tool for evaluating corporate financial viability by management and investors, eco-ratio analysis should be brought to the fore to provide a succinct measurement about the linkage between environmental performance and conventional business performance. It is hoped that this suggestion will usher in a nuance debate and approach in the teaching, research and practice of environmental management and sustainability accounting

  1. Delays help German utilities maintain self-financing ratios

    International Nuclear Information System (INIS)

    Radtke, G.

    1979-01-01

    Estimates of electricity consumption have been substantially reduced and nuclear plant is now expected to be 22% of total generating capacity in 1985 instead of the earlier forecast of 36%. The decline in the ordering of new plant has benefited the financial position of the electricity utilities and the expected fall in self-financing ratios has not occurred. (U.K.)

  2. Investigation of self-indicating radiation personal dosimeter

    International Nuclear Information System (INIS)

    Xia Wen; Ye Honsheng; Lin Min; Xu Lijun; Chen Kesheng; Chen Yizhen

    2014-01-01

    A self-indicating radiation personal dosimeter was investigated using radiation sensitive material diacetylene monomer PCDA, which was a component of the polymerization system. The substrate material, solvent, sensitive material, solution temperature, thickness of film and the preparation method were studied. The dosimeter colour changes from white to blue when exposed 0.1-2.5 Gy, and the linearly dependent coefficient of the exposure response is 0.9998, the stability of absorbency in two weeks after exposure is testified well. It can be used as self-indicating radiation alert personal dosimeter. (authors)

  3. [Waist-to-height ratio is an indicator of metabolic risk in children].

    Science.gov (United States)

    Valle-Leal, Jaime; Abundis-Castro, Leticia; Hernández-Escareño, Juan; Flores-Rubio, Salvador

    2016-01-01

    Abdominal fat, particularly visceral, is associated with a high risk of metabolic complications. The waist-height ratio (WHtR) is used to assess abdominal fat in individuals of all ages. To determine the ability of the waist-to-height ratio to detect metabolic risk in mexican schoolchildren. A study was conducted on children between 6 and 12 years. Obesity was diagnosed as a body mass index (BMI) ≥ 85th percentile, and an ICE ≥0.5 was considered abdominal obesity. Blood levels of glucose, cholesterol and triglycerides were measured. The sensitivity, specificity, positive predictive and negative value, area under curve, the positive likelihood ratio and negative likelihood ratio of the WHtR and BMI were calculated in order to identify metabolic alterations. WHtR and BMI were compared to determine which had the best diagnostic efficiency. Of the 223 children included in the study, 51 had hypertriglyceridaemia, 27 with hypercholesterolaemia, and 9 with hyperglycaemia. On comparing the diagnostic efficiency of WHtR with that of BMI, there was a sensitivity of 100% vs. 56% for hyperglycaemia, 93 vs. 70% for cholesterol, and 76 vs. 59% for hypertriglyceridaemia. The specificity, negative predictive value, positive predictive value, positive likelihood ratio, negative likelihood ratio, and area under curve were also higher for WHtR. The WHtR is a more efficient indicator than BMI in identifying metabolic risk in mexican school-age. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Stuttering generalization self-measure: Preliminary development of a self-measuring tool.

    Science.gov (United States)

    Alameer, Mohammad; Meteyard, Lotte; Ward, David

    2017-09-01

    Generalization of treatment is considered a difficult task for clinicians and people who stutter (PWS), and can constitute a barrier to long-term treatment success. To our knowledge, there are no standardized tests that collect measurement of the behavioral and cognitive aspects alongside the client's self-perception in real-life speaking situations. This paper describes the preliminary development of a Stuttering Generalization Self-Measure (SGSM). The purpose of SGSM is to assess 1) stuttering severity and 2) speech-anxiety level during real-life situations as perceived by PWS. Additionally, this measurement aims to 3) investigate correlations between stuttering severity and speech-anxiety level within the same real-life situation. The SGSM initially reported includes nine speaking situations designed that are developed to cover a variety of frequent speaking scenario situations. However, two of these were less commonly encountered by participants and subsequently not included in the final analyses. Items were created according to five listener categories (family and close friends, acquaintances, strangers, persons of authority, and giving a short speech to small audience). Forty-three participants (22 PWS, and 21 control) aged 18 to 53 years were asked to complete the assessment in real-life situations. Analyses indicated that test-retest reliability was high for both groups. Discriminant validity was also achieved as the SGSM scores significantly differed between the controls and PWS two groups for stuttering and speech-anxiety. Convergent validity was confirmed by significant correlations between the SGSM and other speech-related anxiety measures. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Patient-reported quality indicators for osteoarthritis: a patient and public generated self-report measure for primary care.

    Science.gov (United States)

    Blackburn, Steven; Higginbottom, Adele; Taylor, Robert; Bird, Jo; Østerås, Nina; Hagen, Kåre Birger; Edwards, John J; Jordan, Kelvin P; Jinks, Clare; Dziedzic, Krysia

    2016-01-01

    People with osteoarthritis desire high quality care, support and information. However, the quality of care for people with OA in general practice is not routinely collected. Quality Indicators can be used to benefit patients by measuring whether minimum standards of quality care are being met from a patient perspective. The aim of this study was to describe how a Research User Group (RUG) worked alongside researchers to co-produce a set of self-reported quality indicators for people with osteoarthritis when visiting their general practitioner or practice nurse (primary care). These were required in the MOSAICS study, which developed and evaluated a new model of supported self-management of OA to implement the NICE quality standards for OA. This article describes the public involvement in the MOSAICS study. This was 1) the co-development by RUG members and researchers of an Osteoarthritis Quality Indicators United Kingdom (OA QI (UK)) questionnaire for use in primary care, and 2) the comparison of the OA QI (UK) with a similar questionnaire developed in Norway. This study shows how important and effective a research user group can be in working with researchers in developing quality care indicators for osteoarthritis for use in a research study and, potentially, routine use in primary care. The questionnaire is intended to benefit patients by enabling the assessment of the quality of primary care for osteoarthritis from a patient's perspective. The OA QI (UK) has been used to examine differences in the quality of osteoarthritis care in four European countries. Background People with osteoarthritis (OA) desire high quality care, support and information about OA. However, the quality of care for people with OA in general practice is not routinely collected. Quality Indicators (QI) can be used to benefit patients by measuring whether minimum standards of quality care (e.g. NICE quality standards) are being met from a patient perspective. A Research User Group (RUG

  6. Zinc isotope ratios of bones and teeth as new dietary indicators: results from a modern food web (Koobi Fora, Kenya)

    Science.gov (United States)

    Jaouen, Klervia; Beasley, Melanie; Schoeninger, Margaret; Hublin, Jean-Jacques; Richards, Michael P.

    2016-05-01

    In order to explore the possibilities of using zinc (Zn) stable isotope ratios as dietary indicators, we report here on the measurements of the ratio of stable isotopes of zinc (66Zn/64Zn, expressed here as δ66Zn) in bioapatite (bone and dental enamel) of animals from a modern food web in the Koobi Fora region of the Turkana Basin in Kenya. We demonstrate that δ66Zn values in both bone and enamel allow a clear distinction between carnivores and herbivores from this food web. Differences were also observed between browsers and grazers as well as between carnivores that consumed bone (i.e. hyenas) compared to those that largely consume flesh (i.e. lions). We conclude that Zn isotope ratio measurements of bone and teeth are a new and promising dietary indicator.

  7. Measurement of self-evaluative motives: a shopping scenario.

    Science.gov (United States)

    Wajda, Theresa A; Kolbe, Richard; Hu, Michael Y; Cui, Annie Peng

    2008-08-01

    To develop measures of consumers' self-evaluative motives of Self-verification, Self-enhancement, and Self-improvement within the context of a mall shopping environment, an initial set of 49 items was generated by conducting three focus-group sessions. These items were subsequently converted into shopping-dependent motive statements. 250 undergraduate college students responded on a 7-point scale to each statement as these related to the acquisition of recent personal shopping goods. An exploratory factor analysis yielded five factors, accounting for 57.7% of the variance, three of which corresponded to the Self-verification motive (five items), Self-enhancement motive (three items), and Self-improvement motive (six items). These 14 items, along with 9 reconstructed items, yielded 23 items retained and subjected to additional testing. In a final round of data collection, 169 college students provided data for exploratory factor analysis. 11 items were used in confirmatory factor analysis. Analysis indicated that the 11-item scale adequately captured measures of the three self-evaluative motives. However, further data reduction produced a 9-item scale with marked improvement in statistical fit over the 11-item scale.

  8. Determination of hydrogen/deuterium ratio with neutron measurements on MAST

    Energy Technology Data Exchange (ETDEWEB)

    Klimek, I., E-mail: iwona.klimek@physics.uu.se; Cecconello, M.; Ericsson, G. [Department of Physics and Astronomy, Uppsala University, Uppsala (Sweden); Sharapov, S. E.; Harrison, J. [CCFE, Culham Science Centre, Abingdon (United Kingdom)

    2014-11-15

    On MAST, compressional Alfvén eigenmodes can be destabilized by the presence of a sufficiently large population of energetic particles in the plasma. This dependence was studied in a series of very similar discharges in which increasing amounts of hydrogen were puffed into a deuterium plasma. A simple method to estimate the isotopic ratio n{sub H}/n{sub D} using neutron emission measurements is here described. The inferred isotopic ratio ranged from 0.0 to 0.6 and no experimental indication of changes in radial profile of n{sub H}/n{sub D} were observed. These findings are confirmed by TRANSP/NUBEAM simulations of the neutron emission.

  9. Does Self-Esteem Have an Interpersonal Imprint Beyond Self-Reports? A Meta-Analysis of Self-Esteem and Objective Interpersonal Indicators.

    Science.gov (United States)

    Cameron, Jessica J; Granger, Steve

    2018-02-01

    Self-esteem promises to serve as the nexus of social experiences ranging from social acceptance, interpersonal traits, interpersonal behavior, relationship quality, and relationship stability. Yet previous researchers have questioned the utility of self-esteem for understanding relational outcomes. To examine the importance of self-esteem for understanding interpersonal experiences, we conducted systematic meta-analyses on the association between trait self-esteem and five types of interpersonal indicators. To ensure our results were not due to self-esteem biases in perception, we focused our meta-analyses to 196 samples totaling 121,300 participants wherein researchers assessed interpersonal indicators via outsider reports. Results revealed that the association between self-esteem and the majority of objective interpersonal indicators was small to moderate, lowest for specific and distal outcomes, and moderated by social risk. Importantly, a subset of longitudinal studies suggests that self-esteem predicts later interpersonal experience. Our results should encourage researchers to further explore the link between self-esteem and one's interpersonal world.

  10. [Study of self-reported health of people living near point sources of environmental pollution: a review. First part: health indicators].

    Science.gov (United States)

    Daniau, C; Dor, F; Eilstein, D; Lefranc, A; Empereur-Bissonnet, P; Dab, W

    2013-08-01

    Epidemiological studies have investigated the health impacts of local sources of environmental pollution using as an outcome variable self-reported health, reflecting the overall perception interviewed people have of their own health. This work aims at analyzing the advantages and the results of this approach. A first step focused on describing the indicators. The literature on indicators of self-reported health was reviewed, leading to a discussion on data collection, selection of health effects, data processing, and construction of indicators. The literature review concerned 51 articles. The use of self-reported health indicators allowed the studies to take into account the health concerns and complaints of populations exposed to environmental pollution. Various indicators of self-reported health were used in the studies. They measured physical, psychological and general dimensions of health. Standardized questionnaires were used less often than ad hoc questionnaires (78% of studies) developed to fit the needs of a given study. Three standardized questionnaires were used more frequently: the MOS Short-Form Health Survey (SF-36) to measure general health perceptions, the General Health Questionnaire (GHQ), and the Symptoms Checklist (SCL-90) to measure psychological distress. The choice of self-reported health indicators is a compromise between specificity of the studied health issues within a given environment and standardization of the questionnaires used to measure them. Such standardization is necessary to ensure the validity and the reliability of the information collected across time and situations. The psychometric properties of the measuring questionnaires are rarely estimated or verified when they are used. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  11. Platinum stable isotope ratio measurements by double-spike multiple collector ICPMS

    DEFF Research Database (Denmark)

    Creech, John; Baker, Joel; Handler, Monica

    2013-01-01

    We present a new technique for the precise determination of platinum (Pt) stable isotope ratios by multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) using two different Pt double-spikes ( Pt-Pt and Pt-Pt). Results are expressed relative to the IRMM-010 Pt isotope standard......) can be obtained on Pt stable isotope ratios with either double-spike. Elemental doping tests reveal that double-spike corrected Pt stable isotope ratios are insensitive to the presence of relatively high (up to 10%) levels of matrix elements, although the Pt-Pt double-spike is affected by an isobaric...... = 7.308%) results in a redefined Pt atomic weight of 195.08395 ± 0.00068. Using our technique we have measured small, reproducible and statistically significant offsets in Pt stable isotope ratios between different Pt element standards and the IRMM-010 standard, which potentially indicates...

  12. High Precision Measurement of the Proton Elastic Form Factor Ratio at Low Q2

    Energy Technology Data Exchange (ETDEWEB)

    Xiaohui Zhan

    2009-12-01

    A high precision measurement of the proton elastic form factor ratio µpGEp/GMp in the range Q2 = 0.3–0.7 GeV2/c2 was performed using recoil polarimetry in Jefferson Lab Hall A. In this low Q2 range, previous data from LEDEX [5] along with many fits and calculations [2, 3, 4] indicate substantial deviations of the ratio from unity. In this new measurement, with 80% polarized electron beam for 24 days, we are able to achieve <1% statistical uncertainty. Preliminary results are a few percent lower than expected from previous world data and fits, indicating a smaller GEp at this region. Beyond the intrinsic interest in nucleon structure, the improved form factor measurements also have implications for DVCS, determinations of the proton Zemach radius and strangeness form factors through parity violation experiments.

  13. Ratio method of measuring W boson mass

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Feng [Stony Brook Univ., NY (United States)

    2010-08-01

    This dissertation describes an alternative method of measuring the W boson mass in DØ experiment. Instead of extracting MW from the fitting of W → ev fast Monte Carlo simulations to W → ev data as in the standard method, we make the direct fit of transverse mass between W → ev data and Z → ee data. One of the two electrons from Z boson is treated as a neutrino in the calculation of transverse mass. In ratio method, the best fitted scale factor corresponds to the ratio of W and Z boson mass (MW/MZ). Given the precisely measured Z boson mass, W mass is directly fitted from W → ev and Z → ee data. This dissertation demonstrates that ratio method is a plausible method of measuring the W boson mass. With the 1 fb-1 DØ Run IIa dataset, ratio method gives MW = 80435 ± 43(stat) ± 26(sys) MeV.

  14. Development and validation of a self-reported periodontal disease measure among Jordanians.

    Science.gov (United States)

    Khader, Yousef; Alhabashneh, Rola; Alhersh, Fadi

    2015-08-01

    The development of self-reported measures of periodontal disease would be of great benefit to facilitate epidemiological studies of periodontal disease on a larger scale, and to allow for surveillance of the periodontal condition of populations over time. To develop a culturally adapted self-reported measure of periodontal disease, test its predictive and discriminative validity and establish a cut-off value for this measure to diagnose periodontal disease. A total of 288 Jordanian adults completed the questionnaire assessing self-reported periodontal health (18 questions) and underwent periodontal examination. Of the 18 questions, six were significantly associated with at least one clinical definition of periodontitis and were used to constitute the self-reported periodontal disease measure. Receiver-operating characteristics (ROC) curve analyses were used to examine the overall discriminatory power, sensitivity and specificity, and corresponding cut-off points of the self-reported periodontal disease measure. ROC analysis showed that the self-reported periodontal disease measure had an excellent performance to discriminate between those with and without periodontal disease, regardless of the clinical definition used. A score of 2, on a scale of 0 to 6, had the highest sensitivity and specificity to detect periodontal disease when defined by all study criteria. Significant associations were observed between self-reported periodontal disease measures and all clinical definitions in the regression analysis (the odds ratio ranged from 8.31 to 18.96), according to the clinical definition to be predicted. Self-reported periodontal disease measures have excellent predictive and discriminative validity when tested against clinical definitions, and severity and extent of periodontal disease. © 2015 FDI World Dental Federation.

  15. The patients' perspective of international normalized ratio self-testing, remote communication of test results and confidence to move to self-management.

    Science.gov (United States)

    Grogan, Anne; Coughlan, Michael; Prizeman, Geraldine; O'Connell, Niamh; O'Mahony, Nora; Quinn, Katherine; McKee, Gabrielle

    2017-12-01

    To elicit the perceptions of patients, who self-tested their international normalized ratio and communicated their results via a text or phone messaging system, to determine their satisfaction with the education and support that they received and to establish their confidence to move to self-management. Self-testing of international normalized ratio has been shown to be reliable and is fast becoming common practice. As innovations are introduced to point of care testing, more research is needed to elicit patients' perceptions of the self-testing process. This three site study used a cross-sectional prospective descriptive survey. Three hundred and thirty patients who were prescribed warfarin and using international normalized ratio self-testing were invited to take part in the study. The anonymous survey examined patient profile, patients' usage, issues, perceptions, confidence and satisfaction with using the self-testing system and their preparedness for self-management of warfarin dosage. The response rate was 57% (n = 178). Patients' confidence in self-testing was high (90%). Patients expressed a high level of satisfaction with the support received, but expressed the need for more information on support groups, side effects of warfarin, dietary information and how to dispose of needles. When asked if they felt confident to adjust their own warfarin levels 73% agreed. Chi-squared tests for independence revealed that none of the patient profile factors examined influenced this confidence. The patients cited the greatest advantages of the service were reduced burden, more autonomy, convenience and ease of use. The main disadvantages cited were cost and communication issues. Patients were satisfied with self-testing. The majority felt they were ready to move to self-management. The introduction of innovations to remote point of care testing, such as warfarin self-testing, needs to have support at least equal to that provided in a hospital setting. © 2017 John

  16. Comparison of Self-Report Versus Sensor-Based Methods for Measuring the Amount of Upper Limb Activity Outside the Clinic.

    Science.gov (United States)

    Waddell, Kimberly J; Lang, Catherine E

    2018-03-10

    To compare self-reported with sensor-measured upper limb (UL) performance in daily life for individuals with chronic (≥6mo) UL paresis poststroke. Secondary analysis of participants enrolled in a phase II randomized, parallel, dose-response UL movement trial. This analysis compared the accuracy and consistency between self-reported UL performance and sensor-measured UL performance at baseline and immediately post an 8-week intensive UL task-specific intervention. Outpatient rehabilitation. Community-dwelling individuals with chronic (≥6mo) UL paresis poststroke (N=64). Not applicable. Motor Activity Log amount of use scale and the sensor-derived use ratio from wrist-worn accelerometers. There was a high degree of variability between self-reported UL performance and the sensor-derived use ratio. Using sensor-based values as a reference, 3 distinct categories were identified: accurate reporters (reporting difference ±0.1), overreporters (difference >0.1), and underreporters (difference sensor-based assessment. Participants did not consistently or accurately self-report UL performance when compared with the sensor-derived use ratio. Although self-report and sensor-based assessments are moderately associated and appear similar conceptually, these results suggest self-reported UL performance is often not consistent with sensor-measured performance and the measures cannot be used interchangeably. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Measurement and application of purine derivatives: Creatinine ratio in spot urine samples of ruminants

    International Nuclear Information System (INIS)

    Chen, X.B.; Jayasuriya, M.C.N.; Makkar, H.P.S.

    2004-01-01

    The daily excretion of purine derivatives in urine has been used to estimate the supply of microbial protein to ruminant animals. The method provides a simple and non-invasive tool to indicate the nutritional status of farm animals. However due to the need for complete collection of urine the potential application at farm level is restricted. Research conducted under the FAO/IAEA Co-ordinated Research Project has indicated that it is possible to use the purine derivatives:creatinine ratio measured in several spot urine samples collected within a day, as an index of microbial protein supply in a banding system for farm application. Some theoretical and experimental aspects in the measurement of purine derivatives:creatinine ratio in spot urine samples and the possible application of the banding system at the farm level are discussed. (author)

  18. Measuring weight self-stigma: the weight self-stigma questionnaire.

    Science.gov (United States)

    Lillis, Jason; Luoma, Jason B; Levin, Michael E; Hayes, Steven C

    2010-05-01

    Stigma associated with being overweight or obese is widespread. Given that weight loss is difficult to achieve and maintain, researchers have been calling for interventions that reduce the impact of weight stigma on life functioning. Sound measures that are sensitive to change are needed to help guide and inform intervention studies. This study presents the weight self-stigma questionnaire (WSSQ). The WSSQ has 12 items and is designed for use only with populations of overweight or obese persons. Two samples of participants--one treatment seeking, one nontreatment seeking--were used for validation (N = 169). Results indicate that the WSSQ has good reliability and validity, and contains two distinct subscales-self-devaluation and fear of enacted stigma. The WSSQ could be useful for identifying individuals who may benefit from a stigma reduction intervention and may also help evaluate programs designed to reduce stigma.

  19. Uranium isotope ratio measurements in field settings

    International Nuclear Information System (INIS)

    Shaw, R.W.; Barshick, C.M.; Young, J.P.; Ramsey, J.M.

    1997-01-01

    The authors have developed a technique for uranium isotope ratio measurements of powder samples in field settings. Such a method will be invaluable for environmental studies, radioactive waste operations, and decommissioning and decontamination operations. Immediate field data can help guide an ongoing sampling campaign. The measurement encompasses glow discharge sputtering from pressed sample hollow cathodes, high resolution laser spectroscopy using conveniently tunable diode lasers, and optogalvanic detection. At 10% 235 U enrichment and above, the measurement precision for 235 U/( 235 U+ 238 U) isotope ratios was ±3%; it declined to ±15% for 0.3% (i.e., depleted) samples. A prototype instrument was constructed and is described

  20. Self-consciousness concept and assessment in self-report measures

    Science.gov (United States)

    DaSilveira, Amanda; DeSouza, Mariane L.; Gomes, William B.

    2015-01-01

    This study examines how self-consciousness is defined and assessed using self-report questionnaires (Self-Consciousness Scale (SCS), Self-Reflection and Insight Scale, Self-Absorption Scale, Rumination-Reflection Questionnaire, and Philadelphia Mindfulness Scale). Authors of self-report measures suggest that self-consciousness can be distinguished by its private/public aspects, its adaptive/maladaptive applied characteristics, and present/past experiences. We examined these claims in a study using 602 young adults to whom the aforementioned scales were administered. Data were analyzed as follows: (1) correlation analysis to find simple associations between the measures; (2) factorial analysis using Oblimin rotation of total scores provided from the scales; and (3) factorial analysis considering the 102 items of the scales all together. It aimed to clarify relational patterns found in the correlations between SCSs, and to identify possible latent constructs behind these scales. Results support the adaptive/maladaptive aspects of self-consciousness, as well as distinguish to some extent public aspects from private ones. However, some scales that claimed to be theoretically derived from the concept of Private Self-Consciousness correlated with some of its public self-aspects. Overall, our findings suggest that while self-reflection measures tend to tap into past experiences and judged concepts that were already processed by the participants’ inner speech and thoughts, the Awareness measure derived from Mindfulness Scale seems to be related to a construct associated with present experiences in which one is aware of without any further judgment or logical/rational symbolization. This sub-scale seems to emphasize the role that present experiences have in self-consciousness, and it is argued that such a concept refers to what has been studied by phenomenology and psychology over more than 100 years: the concept of pre-reflective self-conscious. PMID:26191030

  1. Platelet indices and neutrophil to lymphocyte ratio in adults with ...

    African Journals Online (AJOL)

    Background: A study was performed in adults with acute appendicitis and matched controls to assess the utility of the platelet indices and neutrophil to lymphocyte ratio, as a diagnostic adjunct. Methods: Data were retrospectively collected from a complete blood count test of 155 adult patients (72 men and 83 women) with ...

  2. Reproducibility of isotope ratio measurements

    International Nuclear Information System (INIS)

    Elmore, D.

    1981-01-01

    The use of an accelerator as part of a mass spectrometer has improved the sensitivity for measuring low levels of long-lived radionuclides by several orders of magnitude. However, the complexity of a large tandem accelerator and beam transport system has made it difficult to match the precision of low energy mass spectrometry. Although uncertainties for accelerator measured isotope ratios as low as 1% have been obtained under favorable conditions, most errors quoted in the literature for natural samples are in the 5 to 20% range. These errors are dominated by statistics and generally the reproducibility is unknown since the samples are only measured once

  3. Evaluation of self-absorption coefficients of aluminum emission lines in laser-induced breakdown spectroscopy measurements

    International Nuclear Information System (INIS)

    El Sherbini, A.M.; El Sherbini, Th.M.; Hegazy, H.; Cristoforetti, G.; Legnaioli, S.; Palleschi, V.; Pardini, L.; Salvetti, A.; Tognoni, E.

    2005-01-01

    In quantitative Laser Induced Breakdown Spectroscopy (LIBS) measurements it is essential to account for the effect of self-absorption on the emission lines intensity. In order to quantify this effect, in this paper we propose a simple method for evaluating the ratio between the actual measured line intensity and the intensity expected in absence of self-absorption and, if necessary, correcting the effect of self-absorption on line intensity. The method, based on a homogeneous plasma model, is applicable when the plasma electron density is known and in particular to lines whose Stark broadening parameter is available

  4. Absolute measurement of the isotopic ratio of a water sample with very low deuterium content

    International Nuclear Information System (INIS)

    Hagemann, R.; Nief, G.; Roth, E.

    1968-01-01

    The presence of H 3+ ions which are indistinguishable from HD + ions presents the principal difficulty encountered in the measurement of isotopic ratios of water samples with very low deuterium contents using a mass spectrometer. Thus, when the sample contains no deuterium, the mass spectrometer does not indicate zero. By producing, in situ, from the sample to be measured, water vapor with an isotopic ratio very close to zero using a small distilling column, this difficulty is overcome. This column, its operating parameters, as well as the way in which the measurements are made are described. An arrangement is employed in which the isotopic ratios can be measured with a sensitivity better than 0.01 x 10 -6 . The method is applied to the determination of the isotopic ratios of three low deuterium content water samples. The results obtained permit one to assign to the sample with the lowest deuterium content an absolute value equal to 1.71 ± 0.03 ppm. This water sample is a primary standard from which is determined the isotopic ratio of a natural water sample which serves as the laboratory standard. (author) [fr

  5. Parental self-efficacy and its measurement - an evaluation of a parental self-efficacy measurement scale.

    Science.gov (United States)

    Purssell, Edward; While, Alison

    2013-05-01

    To field test a parental self-efficacy scale regarding its acceptability and feasibility and to describe parental self-efficacy in a convenience sample of parents with children aged 6 years old or less. Self-care within families is increasingly emphasised in health policy as a means of maximising healthcare resources. This study reports the field testing of a scale designed to measure parental self-efficacy. Cross-sectional survey of parents of children aged 6 years old or less. Subjects were recruited through a parenting internet website (n = 84) and local parenting and community organisations (n = 68) and asked to complete a questionnaire containing the scale. Data collection took place between January and August 2011. The scale, previously validated with an expert panel of professionals, gathered information about parental self-efficacy when administered either directly or through an on-line data collection portal, although there were more missing data when administered via the Internet. Although convenience and self-selecting samples precluded parameter estimation, areas of concern highlighted were difficulties differentiating children with serious illnesses and the use of the Personal Child Health Record. Use of the Internet was widespread, as was use of community pharmacists and nursery staff. Although the primary purpose was not to collect specific data, the data indicated the continuing concern of parents regarding serious illness and where additional investment may be required to meet parental needs and expectations. The previously validated scale can be used to collect information about parental self-efficacy either through a paper questionnaire or the Internet. Although there was slightly more missing data from the Internet version, the ease of its administration makes this an attractive option. Parents generally reported high levels of self-efficacy and satisfaction with services; however, the scale was able to identify areas where further investment

  6. Do impression management and self-deception distort self-report measures with content of dynamic risk factors in offender samples? A meta-analytic review.

    Science.gov (United States)

    Hildebrand, Martin; Wibbelink, Carlijn J M; Verschuere, Bruno

    Self-report measures provide an important source of information in correctional/forensic settings, yet at the same time the validity of that information is often questioned because self-reports are thought to be highly vulnerable to self-presentation biases. Primary studies in offender samples have provided mixed results with regard to the impact of socially desirable responding on self-reports. The main aim of the current study was therefore to investigate-via a meta-analytic review of published studies-the association between the two dimensions of socially desirable responding, impression management and self-deceptive enhancement, and self-report measures with content of dynamic risk factors using the Balanced Inventory of Desirable Responding (BIDR) in offender samples. These self-report measures were significantly and negatively related with self-deception (r = -0.120, p impression management (r = -0.158, p impression management effect with the trim and fill method indicating that the relation is probably even smaller (r = -0.07). The magnitude of the effect sizes was small. Moderation analyses suggested that type of dynamic risk factor (e.g., antisocial cognition versus antisocial personality), incentives, and publication year affected the relationship between impression management and self-report measures with content of dynamic risk factors, whereas sample size, setting (e.g., incarcerated, community), and publication year influenced the relation between self-deception and these self-report measures. The results indicate that the use of self-report measures to assess dynamic risk factors in correctional/forensic settings is not inevitably compromised by socially desirable responding, yet caution is warranted for some risk factors (antisocial personality traits), particularly when incentives are at play. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Precise and accurate isotope ratio measurements by ICP-MS.

    Science.gov (United States)

    Becker, J S; Dietze, H J

    2000-09-01

    The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.

  8. LITERATURE SURVEY ON ISOTOPIC ABUNDANCE RATIO MEASUREMENTS - 2001-2005

    International Nuclear Information System (INIS)

    HOLDEN, N.E.

    2005-01-01

    Along with my usual weekly review of the published literature for new nuclear data, I also search for new candidates for best measurements of isotopic abundances from a single source. Most of the published articles, that I previously had found in the Research Library at the Brookhaven Lab, have already been sent to the members of the Atomic Weights Commission, by either Michael Berglund or Thomas Walczyk. In the last few days, I checked the published literature for any other articles in the areas of natural variations in isotopic abundance ratios, measurements of isotopic abundance ratios on samples of extra-terrestrial material and isotopic abundance ratio measurements performed using ICPMS instruments. Hopefully this information will be of interest to members of the Commission, the sub-committee on isotopic abundance measurements (SIAM), members of the former sub-committee on natural isotopic fractionation (SNIF), the sub-committee on extra-terrestrial isotope ratios (SETIR), the RTCE Task Group and the Guidelines Task Group, who are dealing with ICPMS and TIMS comparisons. In the following report, I categorize the publications in one of four areas. Measurements performed using either positive or negative ions with Thermal Ionization Mass Spectrometer, TIMS, instruments; measurements performed on Inductively Coupled Plasma Mass Spectrometer, ICPMS, instruments; measurements of natural variations of the isotopic abundance ratios; and finally measurements on extra-terrestrial samples with instrumentation of either type. There is overlap in these areas. I selected out variations and ET results first and then categorized the rest of the papers by TIMS and ICPMS

  9. FINANCING CAPACITY, AN INDICATOR OF SELF FINANCING FOR COMPANIES

    Directory of Open Access Journals (Sweden)

    Teodor Hada

    2013-12-01

    Full Text Available In the introduction of this paper the research objectives are presented on a case study, the research method, as well as the literature in the field and the novelty of this study. Furthermore, several aspects on the source of information for determining intermediate management balances are covered. In the third part of the study the indicator of self-financing capacity of companies is determined. The correlation between the self-financing capacity and term debts are shown in the fourth part and the fifth part of this study presents some aspects regarding global self-financing, maintaining self-financing, net self-financing, and finally the results of the study are presented.

  10. Design, manufacture and spin test of high contact ratio helicopter transmission utilizing Self-Aligning Bearingless Planetary (SABP)

    Science.gov (United States)

    Folenta, Dezi; Lebo, William

    1988-01-01

    A 450 hp high ratio Self-Aligning Bearingless Planetary (SABP) for a helicopter application was designed, manufactured, and spin tested under NASA contract NAS3-24539. The objective of the program was to conduct research and development work on a high contact ratio helical gear SABP to reduce weight and noise and to improve efficiency. The results accomplished include the design, manufacturing, and no-load spin testing of two prototype helicopter transmissions, rated at 450 hp with an input speed of 35,000 rpm and an output speed of 350 rpm. The weight power density ratio of these gear units is 0.33 lb hp. The measured airborne noise at 35,000 rpm input speed and light load is 94 dB at 5 ft. The high speed, high contact ratio SABP transmission appears to be significantly lighter and quieter than comtemporary helicopter transmissions. The concept of the SABP is applicable not only to high ratio helicopter type transmissions but also to other rotorcraft and aircraft propulsion systems.

  11. A Self-Report Measure of Assertiveness in Young Adolescents.

    Science.gov (United States)

    Connor, Jane M.; And Others

    1982-01-01

    Reported a self-report measure of adolescents' assertiveness. Items for the scale were presented to sixth-grade students. Factor analysis revealed factors of submissiveness, aggressiveness, and assertiveness. After the validational study, a small assertiveness training program indicated that training effects were obtained and could be generalized…

  12. Measurement of the proton form factor ratio at low momentum transfer

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Moshe [Hebrew Univ. of Jerusalem (Israel)

    2016-08-01

    Experiment E08-007-II measured the proton elastic form factor ratio μGE=GM in the momentum transfer range of Q2 ~ 0.02 - 0.08 GeV2, the lowest ever measured by polarization transfer techniques. The experiment was performed at the Thomas Jefferson National Accelerator Facility in Newport News, Virginia, USA during 2012. A polarized electron beam with energies of 1.1, 1.7, and 2.2 GeV was elastically scattered off a polarized solid NH3 target. The asymmetries between the cross section of positive and negative helicity states of the beam were determined. These asymmetries can be used to determine the form factor ratio. In this thesis, we present the asymmetry analysis of the experiment, discuss the main challenges and show preliminary results for part of the data. Preliminary asymmetries indicate an increase in the form factor ratio above unity. However, a complete analysis is required before any conclusion can be made. Further analysis is ongoing, and final asymmetry results and form factor extraction is expected during 2017. We also present first results for 14N asymmetries for elastic and quasi-elastic scattering. The measured asymmetries are in agreement with the shell model approximation, within the low accuracy of the measurement. A change in the asymmetry sign between the elastic and the quasi-elastic processes is seen, and should motivate further theoretical studies. These experimental asymmetries will also be useful for systematic studies of other experiments using polarized NH3 targets.

  13. Development of a measure of student self-evaluation of physics exam performance

    Science.gov (United States)

    Hagedorn, Eric Anthony

    The central purpose of this study was to provide preliminary evidence of the reliability and validity of the SEVSI - P (Self- evaluation scaled instrument - physics). This instrument, designed to measure student self-evaluation of physics exam performance, was developed in congruence with social cognitive theory. Self-evaluation in this study is defined to consist of two of the three subprocesses of self-regulation: self-observation and judgmental process. As such, the SEVSI - P consists of two subscales, one measuring the frequency and types of self-observations made during a physics exam and one measuring the frequency and types of judgmental comparisons made after an exam. Data from 621 completed surveys, voluntarily taken by first semester algebra/trigonometry based physics students at six Midwestern universities and one Southern university, were analyzed for reliability and factorial validity. Cronbach alphas of .71 and .83 for the self-observation and judgment subscales, respectively, indicate acceptable reliability for the instrument. Confirmatory factor analysis indicates the acceptability of the hypothesis that the data analyzed could have indeed been obtained from the proposed two factor model (self-observation and judgment). The results of this confirmatory factor analysis provide preliminary construct validity for this instrument. A number of theoretically related items were included on the SEVSI - P form to elicity information about the use of goals and pre-planned strategies, actions taken in response to previous poor performances, and emotional responses to performance. A correlational analysis of these items along with the self-observation and judgment subscale scores provided a limited degree of convergent validity for the two subscales. Analyses of variance were done to determine the presence of differences in scoring patterns based on gender or reported ethnic origin. These results indicate slightly higher judgment subscale scores for women and

  14. Skewed sex ratios and criminal victimization in India.

    Science.gov (United States)

    South, Scott J; Trent, Katherine; Bose, Sunita

    2014-06-01

    Although substantial research has explored the causes of India's excessively masculine population sex ratio, few studies have examined the consequences of this surplus of males. We merge individual-level data from the 2004-2005 India Human Development Survey with data from the 2001 India population census to examine the association between the district-level male-to-female sex ratio at ages 15 to 39 and self-reports of victimization by theft, breaking and entering, and assault. Multilevel logistic regression analyses reveal positive and statistically significant albeit substantively modest effects of the district-level sex ratio on all three victimization risks. We also find that higher male-to-female sex ratios are associated with the perception that young unmarried women in the local community are frequently harassed. Household-level indicators of family structure, socioeconomic status, and caste, as well as areal indicators of women's empowerment and collective efficacy, also emerge as significant predictors of self-reported criminal victimization and the perceived harassment of young women. The implications of these findings for India's growing sex ratio imbalance are discussed.

  15. Skewed Sex Ratios and Criminal Victimization in India

    Science.gov (United States)

    South, Scott J.; Trent, Katherine; Bose, Sunita

    2014-01-01

    Although substantial research has explored the causes of India’s excessively masculine population sex ratio, few studies have examined the consequences of this surplus of males. We merge individual-level data from the 2004–2005 India Human Development Survey with data from the 2001 India population census to examine the association between the district-level male-to-female sex ratio at ages 15 to 39 and self-reports of victimization by theft, breaking and entering, and assault. Multilevel logistic regression analyses reveal positive and statistically significant albeit substantively modest effects of the district-level sex ratio on all three victimization risks. We also find that higher male-to-female sex ratios are associated with the perception that young unmarried women in the local community are frequently harassed. Household-level indicators of family structure, socioeconomic status, and caste, as well as areal indicators of women’s empowerment and collective efficacy, also emerge as significant predictors of self-reported criminal victimization and the perceived harassment of young women. The implications of these findings for India’s growing sex ratio imbalance are discussed. PMID:24682921

  16. Cognitive insight in psychosis: the relationship between self-certainty and self-reflection dimensions and neuropsychological measures.

    Science.gov (United States)

    Cooke, Michael A; Peters, Emmanuelle R; Fannon, Dominic; Aasen, Ingrid; Kuipers, Elizabeth; Kumari, Veena

    2010-07-30

    Cognitive insight in schizophrenia encompasses the evaluation and reinterpretation of distorted beliefs and appraisals. We investigated the neuropsychological basis of cognitive insight in psychosis. It was predicted that, like clinical insight, cognitive insight would be associated with a wide range of neuropsychological functions, but would be most strongly associated with measures of executive function. Sixty-five outpatients with schizophrenia or schizoaffective disorder were assessed on tests of intelligence quotient (IQ), executive function, verbal fluency, attention and memory, and completed the Beck Cognitive Insight Scale, which includes two subscales, self-certainty and self-reflection. Higher self-certainty scores reflect greater certainty about being right and more resistant to correction (poor insight), while higher self-reflection scores indicate the expression of introspection and the willingness to acknowledge fallibility (good insight). The self-certainty dimension of poor cognitive insight was significantly associated with lower scores on the Behavioural Assessment of Dysexecutive Syndrome; this relationship was not mediated by IQ. There were no relationships between self-reflection and any neuropsychological measures. We conclude that greater self-certainty (poor cognitive insight) is modestly associated with poorer executive function in psychotic individuals; self-reflection has no association with executive function. The self-certainty and self-reflection dimensions of cognitive insight have differential correlates, and probably different mechanisms, in psychosis. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Divergence Measures as Diversity Indices

    OpenAIRE

    Abou-Moustafa, Karim T.

    2014-01-01

    Entropy measures of probability distributions are widely used measures in ecology, biology, genetics, and in other fields, to quantify species diversity of a community. Unfortunately, entropy-based diversity indices, or diversity indices for short, suffer from three problems. First, when computing the diversity for samples withdrawn from communities with different structures, diversity indices can easily yield non-comparable and hard to interpret results. Second, diversity indices impose weig...

  18. Measuring disability: a systematic review of the validity and reliability of the Global Activity Limitations Indicator (GALI).

    Science.gov (United States)

    Van Oyen, Herman; Bogaert, Petronille; Yokota, Renata T C; Berger, Nicolas

    2018-01-01

    GALI or Global Activity Limitation Indicator is a global survey instrument measuring participation restriction. GALI is the measure underlying the European indicator Healthy Life Years (HLY). Gali has a substantial policy use within the EU and its Member States. The objective of current paper is to bring together what is known from published manuscripts on the validity and the reliability of GALI. Following the PRISMA guidelines, two search strategies (PUBMED, Google Scholar) were combined to identify manuscripts published in English with publication date 2000 or beyond. Articles were classified as reliability studies, concurrent or predictive validity studies, in national or international populations. Four cross-sectional studies (of which 2 international) studied how GALI relates to other health measures (concurrent validity). A dose-response effect by GALI severity level on the association with the other health status measures was observed in the national studies. The 2 international studies (SHARE, EHIS) concluded that the odds of reporting participation restriction was higher in subjects with self-reported or observed functional limitations. In SHARE, the size of the Odds Ratio's (ORs) in the different countries was homogeneous, while in EHIS the size of the ORs varied more strongly. For the predictive validity, subjects were followed over time (4 studies of which one international). GALI proved, both in national and international data, to be a consistent predictor of future health outcomes both in terms of mortality and health care expenditure. As predictors of mortality, the two distinct health concepts, self-rated health and GALI, acted independently and complementary of each other. The one reliability study identified reported a sufficient reliability of GALI. GALI as inclusive one question instrument fits all conceptual characteristics specified for a global measure on participation restriction. In none of the studies, included in the review, there was

  19. Temperature Measurements in the Solar Transition Region Using N III Line Intensity Ratios

    Science.gov (United States)

    Doron, R.; Doschek, G. A.; Laming, J. M.; Feldman, U.; Bhatia, A. K.

    2003-01-01

    UV emission from B-like N and O ions a rather rare opportunity for recording spectral lines in a narrow wavelength range that can potentially be used to derive temperatures relevant to the solar transition region. In these ions, the line intensity ratios of the type (2s2p(sup 2) - 2p(sup 3)) / (2s(sup 2)2p - 2s2p(sup 2)) are very sensitive to the electron temperature. Additionally, the lines involving the ratios fall within a range of only - 12 A; in N III the lines fall in the 980 - 992 A range and in O IV in the 780 - 791 A range. In this work, we explore the use of these atomic systems, primarily in N III, for temperature diagnostics of the transition region by analyzing UV spectra obtained by the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) spectrometer flown on the Solar and Heliospheric Observatory (SOHO). The N III temperature-sensitive line ratios are measured in more than 60 observations. Most of the measured ratios correspond to temperatures in the range 5.7x10(exp 4) - 6.7x10(exp 4) K. This range is considerably lower than the calculated temperature of maximum abundance of N III, which is approx. 7.6x10(exp 4) K. Detailed analysis of the spectra further indicates that the measured ratios are probably somewhat overestimated due to resonant scattering effects in the 2s(sup 2)2p - 2s2p(sup 2) lines and small blends in the 2s2p(sup 2) - 2p3 lines. Actual lower ratios would only increase the disagreement between the ionization balance calculations and present temperature measurements based on a collisional excitation model. In the case of the O IV spectra, we determined that due to the close proximity in wavelength of the weak line (2s2p(sup 2)-2p3 transitions) to a strong Ne VIII line, sufficiently accurate ratio measurements cannot be obtained. Subject headings: atomic data --- atomic processes --- Sun: transition region --- Sun: U V radiation --- techniques: spectroscopic

  20. Computer-controlled detection system for high-precision isotope ratio measurements

    International Nuclear Information System (INIS)

    McCord, B.R.; Taylor, J.W.

    1986-01-01

    In this paper the authors describe a detection system for high-precision isotope ratio measurements. In this new system, the requirement for a ratioing digital voltmeter has been eliminated, and a standard digital voltmeter interfaced to a computer is employed. Instead of measuring the ratio of the two steadily increasing output voltages simultaneously, the digital voltmeter alternately samples the outputs at a precise rate over a certain period of time. The data are sent to the computer which calculates the rate of charge of each amplifier and divides the two rates to obtain the isotopic ratio. These results simulate a coincident measurement of the output of both integrators. The charge rate is calculated by using a linear regression method, and the standard error of the slope gives a measure of the stability of the system at the time the measurement was taken

  1. Flexible Self-Powered GaN Ultraviolet Photoswitch with Piezo-Phototronic Effect Enhanced On/Off Ratio.

    Science.gov (United States)

    Peng, Mingzeng; Liu, Yudong; Yu, Aifang; Zhang, Yang; Liu, Caihong; Liu, Jingyu; Wu, Wei; Zhang, Ke; Shi, Xieqing; Kou, Jinzong; Zhai, Junyi; Wang, Zhong Lin

    2016-01-26

    Flexible self-powered sensing is urgently needed for wearable, portable, sustainable, maintenance-free and long-term applications. Here, we developed a flexible and self-powered GaN membrane-based ultraviolet (UV) photoswitch with high on/off ratio and excellent sensitivity. Even without any power supply, the driving force of UV photogenerated carriers can be well boosted by the combination of both built-in electric field and piezoelectric polarization field. The asymmetric metal-semiconductor-metal structure has been elaborately utilized to enhance the carrier separation and transport for highly sensitive UV photoresponse. Its UV on/off ratio and detection sensitivity reach to 4.67 × 10(5) and 1.78 × 10(12) cm·Hz(0.5) W(1-), respectively. Due to its excellent mechanical flexibility, the piezoelectric polarization field in GaN membrane can be easily tuned/controlled based on piezo-phototronic effect. Under 1% strain, a stronger and broader depletion region can be obtained to further enhance UV on/off ratio up to 154%. As a result, our research can not only provide a deep understanding of local electric field effects on self-powered optoelectronic detection, but also promote the development of self-powered flexible optoelectronic devices and integrated systems.

  2. Changes of explicitly and implicitly measured self-esteem in the treatment of major depression: evidence for implicit self-esteem compensation.

    Science.gov (United States)

    Wegener, Ingo; Geiser, Franziska; Alfter, Susanne; Mierke, Jan; Imbierowicz, Katrin; Kleiman, Alexandra; Koch, Anne Sarah; Conrad, Rupert

    2015-04-01

    Self-esteem has been claimed to be an important factor in the development and maintenance of depression. Whereas explicit self-esteem is usually reduced in depressed individuals, studies on implicitly measured self-esteem in depression exhibit a more heterogeneous pattern of results, and the role of implicit self-esteem in depression is still ambiguous. Previous research on implicit self-esteem compensation (ISEC) revealed that implicit self-esteem can mirror processes of self-esteem compensation under conditions that threaten self-esteem. We assume that depressed individuals experience a permanent threat to their selves resulting in enduring processes of ISEC. We hypothesize that ISEC as measured by implicit self-esteem will decrease when individuals recover from depression. 45 patients with major depression received an integrative in-patient treatment in the Psychosomatic University Hospital Bonn, Germany. Depression was measured by the depression score of the Hospital Anxiety and Depression Scale (HADS-D). Self-esteem was assessed explicitly using the Rosenberg Self-Esteem Scale (RSES) and implicitly by the Implicit Association Test (IAT) and the Name Letter Test (NLT). As expected for a successful treatment of depression, depression scores declined during the eight weeks of treatment and explicit self-esteem rose. In line with our hypothesis, both measures of implicit self-esteem decreased, indicating reduced processes of ISEC. It still remains unclear, under which conditions there is an overlap of measures of implicit and explicit self-esteem. The results lend support to the concept of ISEC and demonstrate the relevance of implicit self-esteem and self-esteem compensation for the understanding of depression. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Axial ratio dependence of the stability of self-interstitials in HCP structures

    International Nuclear Information System (INIS)

    Peng, Qing; Ji, Wei; Huang, Hanchen; De, Suvranu

    2013-01-01

    We investigate the effect of the axial ratio (c/a) on the stability of self-interstitial atoms (SIAs) in hexagonal close-packed crystal structures, using hcp-zirconium as a prototype, through density functional theory based ab initio calculations. The axial ratio is found to dominate the relative stability of SIAs over volumetric strains. We observe that below the ideal value of 1.633, the basal octahedral configuration is the most stable. Above the ideal value, the off-plane SIAs are more stable than in-plane ones

  4. Fast fission ratio and relative conversion ratio measurements in gadolinium poisoned water moderated UO2 lattices

    International Nuclear Information System (INIS)

    Murphy, M.F.

    1984-01-01

    A programme of criticality experiments has been carried out for BNFL by the Battelle reactor facility at Pacific Northwest Laboratories in Washington State, USA. A series of water moderated lattices of 4.3% enriched, 12.7 mm diameter, UO 2 fuel rods was studied, the fuel pitch was varied and the effects of gadolinium poison were measured. This report deals with the measurement of Fast Fission Ratios and Relative Conversion Ratios at the centre of five of the critical lattices. The Fast Fission Ratio (FFR) is defined here as the ratio of the fission rate per atom of U238, to the fission rate per atom of U235. The Relative Conversion Ratio (RCR) is defined as the ratio of the capture rate per ,atom of U238, to the fission rate per atom of U235, in the reactor fuel, relative to the corresponding ratio in a well thermalised neutron spectrum. A major aspect of these measurements was that the packs of foils were prepared at AEEW Winfrith, despatched to the USA for irradiation and returned to Winfrith for counting. This resulted in a considerable logistics problem but by good planning and the co-operation and diligence of all concerned this problem was overcome. However, the long distance involved inevitably meant that samples were not available for measurement until about 28 hours after the irradiation. It was therefore necessary to modify the techniques that are normally used in the Reactor Physics Division Counting Laboratory, where samples are normally available about two hours after shut-down. The techniques used and the results obtained are given below

  5. Correlation Between Acoustic Measurements and Self-Reported Voice Disorders Among Female Teachers.

    Science.gov (United States)

    Lin, Feng-Chuan; Chen, Sheng Hwa; Chen, Su-Chiu; Wang, Chi-Te; Kuo, Yu-Ching

    2016-07-01

    Many studies focused on teachers' voice problems and most of them were conducted using questionnaires, whereas little research has investigated the relationship between self-reported voice disorders and objective quantification of voice. This study intends to explore the relationship of acoustic measurements according to self-reported symptoms and its predictive value of future dysphonia. This is a case-control study. Voice samples of 80 female teachers were analyzed, including 40 self-reported voice disorders (VD) and 40 self-reported normal voice (NVD) subjects. The acoustic measurements included jitter, shimmer, and noise-to-harmonics ratio (NHR). Levene's t test and logistic regression were used to analyze the differences between VD and NVD and the relationship between self-reported voice conditions and the acoustic measurements. To examine whether acoustic measurements can be used to predict further voice disorders, we applied a receiver operating characteristic (ROC) curve to determine the cutoff values and the associated sensitivity and specificity. The results showed that jitter, shimmer, and the NHR of VD were significantly higher than those of NVD. Among the parameters, the NHR and shimmer demonstrated the highest correlation with self-reported voice disorders. By using the NHR ≥0.138 and shimmer ≥0.470 dB as the cutoff values, the ROC curve displayed 72.5% of sensitivity and 75% of specificity, and the overall positive predictive value for subsequent dysphonia achieved 60%. This study demonstrated a significant correlation between acoustic measurements and self-reported dysphonic symptoms. NHR and ShdB are two acoustic parameters that are more able to reflect vocal abnormalities and, probably, to predict subsequent subjective voice disorder. Future research recruiting more subjects in other occupations and genders shall validate the preliminary results revealed in this study. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All

  6. The effect of water to cement ratio on fracture parameters and brittleness of self-compacting concrete

    International Nuclear Information System (INIS)

    Beygi, Morteza H.A.; Kazemi, Mohammad T.; Nikbin, Iman M.; Amiri, Javad. Vaseghi

    2013-01-01

    Highlights: ► Fracture properties of SCC were obtained using two different methods. ► Results showed with decrease of w/c ratio the fracture toughness increases. ► Size effect method can predict the peak load with a good precision for SCC beams. ► The size effect curve showed SCC ductility increases with increase of w/c ratio. - Abstract: The paper describes an experimental research on fracture characteristics of self-compacting concrete (SCC). Three point bending tests conducted on 154 notched beams with different water to cement (w/c) ratios. The specimens were made from mixes with various w/c ratios from 0.7 to 0.35. For all mixes, common fracture parameters were determined using two different methods, the work-of-fracture method (WFM) and the size effect method (SEM). Test results showed that with decrease of w/c ratio from 0.7 to 0.35 in SCC: (a) the fracture toughness increases linearly: (b) the brittleness number is approximately doubled: (c) the effective size of the process zone c f in SEM and the characteristic length (l ch ) in WFM decrease which may be explained by the change in structural porosity of the aggregate–paste transition zone; and (d) the fracture surface of concrete is roughly smoother, which can be attributed to the improved bond strength between the aggregates and the paste. Also, the results showed that there is a correlation between the fracture energy measured by WFM (G F ) and the value measured through SEM (G f ) (G F ≅ 2.92G f )

  7. Measuring the Core Components of Maladaptive Personality: Severity Indices of Personality Problems (SIPP-118)

    NARCIS (Netherlands)

    H. Andrea (Helene); R. Verheul (Roel); C.C. Berghout (Casper); C. Dolan (Conor); P.J.A. van der Kroft (Petra); A.W. Bateman (Anthony); P. Fonagy (Peter); J.J. van Busschbach (Jan)

    2007-01-01

    textabstractThis report describes a series of studies among 2231 subjects on the development of the Severity Indices for Personality Problems (SIPP), a self-report questionnaire measuring the core components of (mal)adaptive personality functioning. Results show that the 16 facets have good

  8. The isotopic composition of lead in man and the environment in Finland: isotope ratios of lead as indicators of pollutant source

    International Nuclear Information System (INIS)

    Keinonen, M.

    1989-01-01

    The isotopic composition of lead was determined in samples from the Helsinki area: in emission sources (gasoline, incinerator and lead smelter emissions, coal), in sources of intake to man (air, diet), in samples representing long-term deposition (lichen, soil, lake sediments) and in human tissue. The measurements of the isotope ratios 206 Pb/ 204 Pb and 206 Pb/ 207 Pb were done by thermal ionization mass spectrometry after chemical separation of lead by anion exchange and cathodic electrodeposition. The origin of lead in man and the environment in the Helsinki area was evaluated by using the differences in the measured isotope ratios as an indicator. The means of the ratios in gasoline ( 206 Pb/ 207 Pb 1.124+-0.026, 206 Pb/ 204 Pb 17.45+-0.42) and the ratios in other emission sources in Helsinki ( 206 Pb/ 207 Pb 1.149-1.226, 206 Pb/ 204 Pb 17.94-19.24) were significantly different. Lead in air samples from Helsinki (1.123+-0.013) could be attributed to gasoline, as lead in soil near a highway (1.136+-0.003). By contrast, isotope ratios measured in lichen (1.148+-0.006) indicated considerable amounts of lead from sources with higher 206 Pb abundances, evidently industrial sources. The isotope ratios in human liver, lung, and bone ( 206 Pb/ 207 Pb 1.142+-0.015, 1.151+-0.011, and 1.156+-0.013, respectively and 206 Pb/ 204 Pb 17.76+-0.28, 17.91+-0.20, and 17.96+-0.09, respectively) were practically the same and no significant dependence of the isotope ratios on age or concentration of lead was seen. In lake sediment cores a correlation was found between the isotope ratios, lead concentration, and depth. The non-anthropogenic lead of high isotope ratios from bedrock was the major component at depths dated older than 100 years. At the surface of the sediment atmospheric lead prevailed, with ratios similar to those of gasoline, air samples and lichen. In the post-1900 layers, anthropogenic lead made up about 40-60% of the total sedimentary lead

  9. Diffusion and the self-measurability

    Directory of Open Access Journals (Sweden)

    Holeček M.

    2009-06-01

    Full Text Available The familiar diffusion equation, ∂g/∂t = DΔg, is studied by using the spatially averaged quantities. A non-local relation, so-called the self-measurability condition, fulfilled by this equation is obtained. We define a broad class of diffusion equations defined by some "diffusion inequality", ∂g/∂t · Δg ≥ 0, and show that it is equivalent to the self-measurability condition. It allows formulating the diffusion inequality in a non-local form. That represents an essential generalization of the diffusion problem in the case when the field g(x, t is not smooth. We derive a general differential equation for averaged quantities coming from the self-measurability condition.

  10. Measurements of K/Π ratio in cosmic radiation

    International Nuclear Information System (INIS)

    Mahon, J.R.P.

    1986-01-01

    Measurements of k/Π ratio in cosmic radiation by its half lives and its fluxes, were carried out. The kaon flux was obtained using the Cherenkov detector, and for pion flux scintillation detectors were used. The final results of K/Π ratio ∼ 0.2 was obtained. (M.C.K.) [pt

  11. Early-age acoustic emission measurements in hydrating cement paste: Evidence for cavitation during solidification due to self-desiccation

    DEFF Research Database (Denmark)

    Lura, Pietro; Couch, J.; Jensen, Ole Mejlhede

    2009-01-01

    . According to these experimental results, the acoustic emission measured around setting time was attributed to cavitation events occurring in the pores of the cement paste due to self-desiccation. This paper shows how acoustic emission might be used to indicate the time when the fluid–solid transition occurs......In this study, the acoustic emission activity of cement pastes was investigated during the first day of hydration. Deaired, fresh cement pastes were cast in sealed sample holders designed to minimize friction and restraint. The majority of acoustic emission events occurred in lower water to cement...... ratio pastes, while cement pastes with higher water to cement ratios showed significantly less acoustic activity. These acoustic events occurred around the time of setting. A layer of water on the surface of the cement pastes substantially reduced acoustic emission activity at the time of setting...

  12. In the eyes of the beholder: A non-self-report measure of workplace deviance.

    Science.gov (United States)

    Stewart, Susan M; Bing, Mark N; Davison, H Kristl; Woehr, David J; McIntyre, Michael D

    2009-01-01

    Because employees may be reluctant to admit to performing deviant acts, the authors of this study reexamined the commonly used self-report measure of workplace deviance developed by R. J. Bennett and S. L. Robinson (2000). Specifically, the self-report measure was modified into a non-self-report measure based on multiple other-reported assessments to address methodological concerns with self-reported information regarding deviant workplace behaviors. The authors assessed the psychometric properties of this new measure by first conducting an exploratory factor analysis, which indicated a 3-factor structure (production deviance, property deviance, and personal aggression). Subsequent confirmatory factor analysis on a different sample verified these findings. Taken together, the results suggest that the content and psychometric qualities of this non-self-report measure of workplace deviance closely represent S. L. Robinson and R. J. Bennett's (1995) original typology of workplace deviance. The potential usefulness of this measure in organizational studies is discussed. (PsycINFO Database Record (c) 2009 APA, all rights reserved).

  13. Measurement of the super-allowed branching ratio of $^{22}$Mg

    CERN Multimedia

    We propose to measure the super-allowed branching ratio and the half-life of $^{22}$Mg, one of the least-well-measured $0^{+} \\rightarrow 0^{+}$ transitions of the 14 nuclei used to determine V$_{ud}$ and to test the unitarity of the CKM matrix. We propose measurements which should allow to significantly improve the precision on the super-allowed branching ratio employing a precisely efficiency calibrated germanium detector and on the half-life. As no method exists to greatly improve (e.g. an order of magnitude) on previous results, the branching ratio and the half-life have to be measured several times with independent methods and in independent experiments.

  14. An approach for measuring the {sup 129}I/{sup 127}I ratio in fish samples

    Energy Technology Data Exchange (ETDEWEB)

    Kusuno, Haruka, E-mail: kusuno@um.u-tokyo.ac.jp [The University Museum, The University of Tokyo, 3-7-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Matsuzaki, Hiroyuki [The University Museum, The University of Tokyo, 3-7-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Nagata, Toshi; Miyairi, Yosuke; Yokoyama, Yusuke [Atmosphere and Ocean Research Institute, The University of Tokyo, 5-1-5, Kashiwanoha, Kashiwa-shi, Chiba 277-8564 (Japan); Ohkouchi, Naohiko [Japan Agency for Marine-Earth Science and Technology, 2-15, Natsushima-cho, Yokosuka-city, Kanagawa 237-0061 (Japan)

    2015-10-15

    The {sup 129}I/{sup 127}I ratio in marine fish samples was measured employing accelerator mass spectrometry. The measurement was successful because of the low experimental background of {sup 129}I. Pyrohydrolysis was applied to extract iodine from fish samples. The experimental background of pyrohydrolysis was checked carefully and evaluated as 10{sup 4}–10{sup 5} atoms {sup 129}I/combustion. The methodology employed in the present study thus required only 0.05–0.2 g of dried fish samples. The methodology was then applied to obtain the {sup 129}I/{sup 127}I ratio of marine fish samples collected from the Western Pacific Ocean as (0.63–1.2) × 10{sup −10}. These values were similar to the ratio for the surface seawater collected at the same station, 0.4 × 10{sup −10}. The {sup 129}I/{sup 127}I ratio of IAEA-414, which was a mix of fish from the Irish Sea and the North Sea, was also measured and determined as 1.82 × 10{sup −7}. Consequently, fish from the Western Pacific Ocean and the North Sea were distinguished by their {sup 129}I/{sup 127}I ratios. The {sup 129}I/{sup 127}I ratio is thus a direct indicator of the area of habitat of fish.

  15. Self-transcendence: conceptualization and measurement.

    Science.gov (United States)

    Levenson, Michael R; Jennings, Patricia A; Aldwin, Carolyn M; Shiraishi, Ray W

    2005-01-01

    Self-transcendence has been hypothesized to be a critical component of wisdom (Curnow, 1999) and adaptation in later life (Tornstam, 1994). It reflects a decreasing reliance on externals for definition of the self, increasing interiority and spirituality, and a greater sense of connectedness with past and future generations. The Adult Self-Transcendence Inventory was administered to 351 individuals along with the NEO-FFI Personality Scale (McCrae & Costa, 1989). A principal axis factor analysis identified two factors: self-transcendence and alienation. The relationships between self-transcendence and neuroticism, openness to experience, extraversion, and agreeableness were significant, although modest, suggesting that self-transcendence cannot be accounted for in terms of positive personality traits alone. As expected, a multiple regression analysis indicated that self-transcendence was negatively related to neuroticism and positively related to meditation practice. The present study appears to lend support to the construct of self-transcendence.

  16. Experiments at the GELINA facility for the validation of the self-indication neutron resonance densitometry technique

    Directory of Open Access Journals (Sweden)

    Rossa Riccardo

    2017-01-01

    Full Text Available Self-Indication Neutron Resonance Densitometry (SINRD is a passive non-destructive method that is being investigated to quantify the 239Pu content in a spent fuel assembly. The technique relies on the energy dependence of total cross sections for neutron induced reaction. The cross sections show resonance structures that can be used to quantify the presence of materials in objects, e.g. the total cross-section of 239Pu shows a strong resonance close to 0.3 eV. This resonance will cause a reduction of the number of neutrons emitted from spent fuel when 239Pu is present. Hence such a reduction can be used to quantify the amount of 239Pu present in the fuel. A neutron detector with a high sensitivity to neutrons in this energy region is used to enhance the sensitivity to 239Pu. This principle is similar to self-indication cross section measurements. An appropriate detector can be realized by surrounding a 239Pu-loaded fission chamber with appropriate neutron absorbing material. In this contribution experiments performed at the GELINA time-of-flight facility of the JRC at Geel (Belgium to validate the simulations are discussed. The results confirm that the strongest sensitivity to the target material was achieved with the self-indication technique, highlighting the importance of using a 239Pu fission chamber for the SINRD measurements.

  17. Measurement of mercury isotopic ratio in stone meteorites by neutron activation analysis

    International Nuclear Information System (INIS)

    Thakur, A.N.

    1997-01-01

    196 Hg and 202 Hg isotopes have been measured by neutron activation analysis in samples of twelve stone meteorites. Hg is extracted from an irradiated sample by stepwise heating. The mercury concentrations vary from 0.07 to 33 ppm. While most of the samples give 196 Hg/ 202 Hg ratios similar to terrestrial value within error limits, in some cases large anomalies are observed. A number of control experiments have been devised, that show the absence of experimental artifacts, during sample preparation, neutron irradiation, chemical separation and counting stages. Several anomalous and normal Hg distillate have been re-irradiated as Hg-diethyl-dithio-carbamate complex to eliminate the influence of neutron self shielding and interfering reactions from matrix elements. The isotopic ratio patterns persist in the distillates too proving that any artifacts during meteorite irradiation and measurement are essentially absent. Both positive and negative anomalies are observed: however, the negative anomalies are much more frequent and abundant. In an extreme case of fine grained magnetic particles of Ambapur Nagla the 196 Hg is apparently absent in the Hg released at 100 deg C. A 2σ 196 Hg/ 202 Hg value is only 6% relative to the monitor. This experiment shows the robustness of neutron activation analysis and suggest some constrains on the formation history of stone meteorites. (author)

  18. Measurement of the temperature coefficient of ratio transformers

    Science.gov (United States)

    Briggs, Matthew E.; Gammon, Robert W.; Shaumeyer, J. N.

    1993-01-01

    We have measured the temperature coefficient of the output of several ratio transformers at ratios near 0.500,000 using an ac bridge and a dual-phase, lock-in amplifier. The two orthogonal output components were each resolved to +/- ppb of the bridge drive signal. The results for three commercial ratio transformers between 20 and 50 C range from 0.5 to 100 ppb/K for the signal component in phase with the bridge drive, and from 4 to 300 ppb/K for the quadrature component.

  19. Physicochemical and biological properties of self-assembled antisense/poly(amidoamine) dendrimer nanoparticles: the effect of dendrimer generation and charge ratio

    OpenAIRE

    Nomani, Alireza; Haririan, Ismaeil; Rahimnia, Ramin; Fouladdel, Shamileh; Gazori, Tarane; Dinarvand, Rassoul; Omidi, Yadollah; Azizi, Ebrahim

    2010-01-01

    To gain a deeper understanding of the physicochemical phenomenon of self-assembled nanoparticles of different generations and ratios of poly (amidoamine) dendrimer (PAMAM) dendrimer and a short-stranded DNA (antisense oligonucleotide), multiple methods were used to characterize these nanoparticles including photon correlation spectroscopy (PCS); zeta potential measurement; and atomic force microscopy (AFM). PCS and AFM results revealed that, in contrast to larger molecules of DNA, smaller mol...

  20. Pathways to Adolescents' Flourishing: Linking Self-Control Skills and Positivity Ratio through Social Support

    Science.gov (United States)

    Orkibi, Hod; Hamama, Liat; Gavriel-Fried, Belle; Ronen, Tammie

    2018-01-01

    This study focused on the ability to experience a high ratio of positive to negative emotions in 807 Israeli adolescents aged 12 to 15 years (50% girls). While considering possible gender differences, we tested a model positing that adolescents' self-control skills would link to their positivity ratio and indirectly through perceived social…

  1. Correlation coefficients of three self-perceived orthodontic treatment need indices

    Directory of Open Access Journals (Sweden)

    Faezeh Eslamipour

    2017-01-01

    Conclusion: Due to the sensitivity and specificity of the three self-perceived indices, these indices are not recommended for population screening and should be used as adjuncts to a normative index for decision-making in orthodontic treatment planning.

  2. Zinc isotope ratios of bones and teeth as new dietary indicators: results from a modern food web (Koobi Fora, Kenya)

    OpenAIRE

    Jaouen, Klervia; Beasley, Melanie; Schoeninger, Margaret; Hublin, Jean-Jacques; Richards, Michael P.

    2016-01-01

    In order to explore the possibilities of using zinc (Zn) stable isotope ratios as dietary indicators, we report here on the measurements of the ratio of stable isotopes of zinc (66Zn/64Zn, expressed here as ?66Zn) in bioapatite (bone and dental enamel) of animals from a modern food web in the Koobi Fora region of the Turkana Basin in Kenya. We demonstrate that ?66Zn values in both bone and enamel allow a clear distinction between carnivores and herbivores from this food web. Differences were ...

  3. Ratio of Circulating Estrogen Receptors Beta and Alpha (ERβ/ERα) Indicates Endoscopic Activity in Patients with Crohn's Disease.

    Science.gov (United States)

    Linares, Pablo M; Algaba, Alicia; Urzainqui, Ana; Guijarro-Rojas, Mercedes; González-Tajuelo, Rafael; Garrido, Jesús; Chaparro, María; Gisbert, Javier P; Bermejo, Fernando; Guerra, Iván; Castellano, Víctor; Fernández-Contreras, María-Encarnación

    2017-10-01

    Data supporting a role of female hormones and/or their receptors in inflammatory bowel disease (IBD) are increasing, but most of them are derived from animal models. Estrogen receptors alpha (ERα) and beta (ERβ) participate in immune and inflammatory response, among a variety of biological processes. Their effects are antagonistic, and the net action of estrogens may depend on their relative proportions. To determine the possible association between the balance of circulating ERβ and ERα (ERβ/ERα) and IBD risk and activity. Serum samples from 145 patients with IBD (79 Crohn's disease [CD] and 66 ulcerative colitis [UC]) and 39 controls were retrospectively studied. Circulating ERα and ERβ were measured by ELISA. Disease activities were assessed by clinical and endoscopic indices specific for CD and UC. Low values of ERβ/ERα ratio were directly associated with clinical (p = 0.019) and endoscopic (p = 0.002) disease activity. Further analyses by type of IBD confirmed a strong association between low ERβ/ERα ratio and CD clinical (p = 0.011) and endoscopic activity (p = 0.002). The receiver operating curve (ROC) analysis showed that an ERβ/ERα ratio under 0.85 was a good marker of CD endoscopic activity (area under the curve [AUC]: 0.84; p = 0.002; sensitivity: 70%; specificity: 91%). ERβ/ERα ratio was not useful to predict UC activity. An ERβ/ERα ratio under 0.85 indicated CD endoscopic activity. The determination of serum ERβ/ERα might be a useful noninvasive screening tool for CD endoscopic activity.

  4. Self-adaptive demodulation for polarization extinction ratio in distributed polarization coupling.

    Science.gov (United States)

    Zhang, Hongxia; Ren, Yaguang; Liu, Tiegen; Jia, Dagong; Zhang, Yimo

    2013-06-20

    A self-adaptive method for distributed polarization extinction ratio (PER) demodulation is demonstrated. It is characterized by dynamic PER threshold coupling intensity (TCI) and nonuniform PER iteration step length (ISL). Based on the preset PER calculation accuracy and original distribution coupling intensity, TCI and ISL can be made self-adaptive to determine contributing coupling points inside the polarizing devices. Distributed PER is calculated by accumulating those coupling points automatically and selectively. Two different kinds of polarization-maintaining fibers are tested, and PERs are obtained after merely 3-5 iterations using the proposed method. Comparison experiments with Thorlabs commercial instrument are also conducted, and results show high consistency. In addition, the optimum preset PER calculation accuracy of 0.05 dB is obtained through many repeated experiments.

  5. Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

    Energy Technology Data Exchange (ETDEWEB)

    Chen, A. [Shenzhen College of International Education, 1st HuangGang Park St., Shenzhen, GuangDong (China); Luo, J. [Department of Biomedical Engineering, University at Buffalo, 332 Bonner Hall, Buffalo, NY 14260-1920 (United States); Wang, A. [Department of Computer Science, Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Broadbent, C. [School of Engineering, Columbia University, 1130 Amsterdam Av., New York, NY 10027 (United States); Zhong, J. [Department of English, Dartmouth College, 6032 Sanborn House, Hanover, NH 03755 (United States); Dilmanian, F.A. [Departments of Radiation Oncology, Neurology, and Radiology, Stony Brook University, Stony Brook, NY 11794 (United States); Zafonte, F.; Zhong, Z. [National Synchrotron Light Source II, Brookhaven National Laboratory, Bldg. 743, Upton, NY 11973 (United States)

    2015-07-11

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. An efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

  6. Measurement of boron isotope ratios in groundwater studies

    International Nuclear Information System (INIS)

    Porteous, N.C.; Walsh, J.N.; Jarvis, K.E.

    1995-01-01

    Boron is present at low levels in groundwater and rainfall in the UK, ranging between 2 and 200 ng ml -1 . A sensitive technique has been developed using inductively coupled plasma mass spectrometry (ICP-MS) to measure boron isotope ratios at low concentrations with a precision (s r ) of between 0.1 and 0.2%. Samples were evaporated to increase elemental boron concentrations to 200 ng ml -1 and interfering matrix elements were removed by an adapted cation-exchange separation procedure. The validity of measuring boron isotopic ratios by ICP-MS at this concentration level is discussed in relation to the theoretical instrument precision attainable based on counting statistics. (author)

  7. Delays help German utilities maintain self-financing ratios. [Financing nuclear power projects

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, G [Dresden Bank, AG (Germany, F.R.)

    1979-05-01

    Estimates of electricity consumption have been substantially reduced and nuclear plant is now expected to be 22% of total generating capacity in 1985 instead of the earlier forecast of 36%. The decline in the ordering of new plant has benefited the financial position of the electricity utilities and the expected fall in self-financing ratios has not occurred.

  8. Efficient estimators for likelihood ratio sensitivity indices of complex stochastic dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Arampatzis, Georgios; Katsoulakis, Markos A.; Rey-Bellet, Luc [Department of Mathematics and Statistics, University of Massachusetts, Amherst, Massachusetts 01003 (United States)

    2016-03-14

    We demonstrate that centered likelihood ratio estimators for the sensitivity indices of complex stochastic dynamics are highly efficient with low, constant in time variance and consequently they are suitable for sensitivity analysis in long-time and steady-state regimes. These estimators rely on a new covariance formulation of the likelihood ratio that includes as a submatrix a Fisher information matrix for stochastic dynamics and can also be used for fast screening of insensitive parameters and parameter combinations. The proposed methods are applicable to broad classes of stochastic dynamics such as chemical reaction networks, Langevin-type equations and stochastic models in finance, including systems with a high dimensional parameter space and/or disparate decorrelation times between different observables. Furthermore, they are simple to implement as a standard observable in any existing simulation algorithm without additional modifications.

  9. Self-transcendence as a measure of spirituality in a sample of older Australian twins.

    Science.gov (United States)

    Kirk, K M; Eaves, L J; Martin, N G

    1999-06-01

    Measures of self-transcendence, physical health and psychological well-being were included in a self-report Health and Lifestyle questionnaire administered to Australian twins aged over 50 between 1993 and 1995. Self-transcendence appears to be higher among older Australian women than men, and was significantly associated with religious affiliation, marital status (in women) and age (in men). No strong correlations were observed between self-transcendence and any measure of psychological or physical health. Additive genetic effects were found to be important in influencing self-transcendence, with heritability estimates of 0.37 and 0.41 for men and women respectively, whilst shared environment effects were not found to be significant. Multivariate modelling of self-transcendence scores and self-reported church attendance behavior indicated substantially different etiologies for these variables, with implications for methods of investigation of religiosity and spirituality.

  10. Measurement of the inclusive charmless and double-charm B branching ratios

    CERN Document Server

    Abreu, P; Adye, T; Adzic, P; Alekseev, G D; Alemany, R; Allport, P P; Almehed, S; Amaldi, Ugo; Amato, S; Andersson, P; Andreazza, A; Antilogus, P; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barbier, R; Bardin, Dimitri Yuri; Barker, G; Baroncelli, A; Bärring, O; Bates, M J; Battaglia, Marco; Baubillier, M; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Belous, K S; Benvenuti, Alberto C; Bérat, C; Berggren, M; Bertini, D; Bertrand, D; Besançon, M; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bizouard, M A; Bloch, D; Bonesini, M; Bonivento, W; Boonekamp, M; Booth, P S L; Borgland, A W; Borisov, G; Bosio, C; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozovic, I; Bozzo, M; Branchini, P; Brand, K D; Brenke, T; Brenner, R A; Brown, R; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschmann, P; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Carena, F; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerruti, C; Chabaud, V; Chapkin, M M; Charpentier, P; Chaussard, L; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Chudoba, J; Collins, P; Colomer, M; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Cowell, J H; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; D'Almagne, B; Damgaard, G; Dauncey, P D; Davenport, Martyn; Da Silva, W; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; Dijkstra, H; Di Ciaccio, Lucia; Di Diodato, A; Djannati, A; Dolbeau, J; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Duperrin, A; Durand, J D; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Ellert, M; Elsing, M; Engel, J P; Erzen, B; Espirito-Santo, M C; Falk, E; Fanourakis, G K; Fassouliotis, D; Fayot, J; Feindt, Michael; Fenyuk, A; Ferrari, P; Ferrer, A; Fichet, S; Firestone, A; Fischer, P A; Flagmeyer, U; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gaspar, M; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gerdyukov, L N; Ghodbane, N; Glege, F; Gokieli, R; Golob, B; González-Caballero, I; Gopal, Gian P; Gorn, L; Górski, M; Gracco, Valerio; Grahl, J; Graziani, E; Green, C; Grefrath, A; Gris, P; Grosdidier, G; Grzelak, K; Günther, M; Guy, J; Hahn, F; Hahn, S; Haider, S; Hajduk, Z; Hallgren, A; Hamacher, K; Harris, F J; Hedberg, V; Heising, S; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Heuser, J M; Higón, E; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Hrubec, Josef; Huet, K; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, C; Juillot, P; Kapusta, F; Karafasoulis, K; Katsanevas, S; Katsoufis, E C; Keränen, R; Khokhlov, Yu A; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klapp, O; Klein, H; Kluit, P M; Knoblauch, D; Kokkinias, P; Koratzinos, M; Korcyl, K; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Krammer, Manfred; Kreuter, C; Kronkvist, I J; Krumshtein, Z; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leisos, A; Leitner, R; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Lethuillier, M; Libby, J; Liko, D; Lipniacka, A; Lippi, I; Lörstad, B; Loken, J G; Lopes, J H; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Mahon, J R; Maio, A; Malek, A; Malmgren, T G M; Malychev, V; Mandl, F; Marco, J; Marco, R P; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, F; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; McPherson, G; Medbo, J; Meroni, C; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Moreau, X; Morettini, P; Münich, K; Mulders, M; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Myklebust, T; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Némécek, S; Neufeld, N; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Nikolenko, M; Niss, P; Nomerotski, A; Normand, Ainsley; Nygren, A; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Orazi, G; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Paiano, S; Pain, R; Paiva, R; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Parzefall, U; Passeri, A; Pegoraro, M; Peralta, L; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Piotto, E; Podobnik, T; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Reinhardt, R; Renton, P B; Resvanis, L K; Richard, F; Rídky, J; Rinaudo, G; Røhne, O M; Romero, A; Ronchese, P; Rosenberg, E I; Rosinsky, P; Roudeau, Patrick; Rovelli, T; Ruhlmann-Kleider, V; Ruiz, A; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sampsonidis, D; Sannino, M; Schneider, H; Schwickerath, U; Schyns, M A E; Scuri, F; Seager, P; Sedykh, Yu; Segar, A M; Sekulin, R L; Shellard, R C; Sheridan, A; Silvestre, R; Simonetto, F; Sissakian, A N; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Solovyanov, O; Sopczak, André; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stampfer, D; Stanescu, C; Stanic, S; Stapnes, Steinar; Stavitski, I; Stevenson, K; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Chikilev, O G; Tegenfeldt, F; Terranova, F; Thomas, J; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Todorova, S; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tranströmer, G; Treille, D; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; van Apeldoorn, G W; van Dam, P; Van Eldik, J; Van Lysebetten, A; Van Vulpen, I B; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Verzi, V; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Waldner, F; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J H; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Wlodek, T; Wolf, G; Yi, J; Yushchenko, O P; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zucchelli, G C; Zumerle, G

    1998-01-01

    The DELPHI experiment at LEP has measured the inclusive charmless $B$ hadron decay branching ratio, the $B$ branching ratio into two charmed particles, and the total number of charmed particles per $B$ decay, using the hadronic Z data taken between 1992 and 1995. The results are extracted from a fit to the $b$-tagging probability distribution based on the precise impact parameter measurements made using the microvertex detector. The inclusive charmless $B$ branching ratio, including $B$ decays into hidden charm ($c\\bar{c}$), is measured to be $0.033 \\pm 0.021$. The $B$ branching ratio into two open charmed particles is $0.136 \\pm 0.042$. The mean number of charmed particles per $B$ decay (including hidden charm) is $1.147 \\pm 0.041$. After subtracting the $B$ decay branching ratio into hidden charm, the charmless $B$ branching ratio is found to be $0.007 \\pm 0.021$, compatible with the Standard Model expectation. Models that predict an additional contribution to the charmless $B$ branching ratio of 0.037 or h...

  11. Measurement of the super-allowed branching ratio of $^{10}$C

    CERN Multimedia

    We propose to measure the super-allowed branching ratio of $^{10}$C, the lightest of all nuclei decaying by a $0^{+} \\rightarrow 0^{+}$ transition. The light nuclei have a much stronger impact on limits of physics beyond the standard model than heavier nuclei. We propose a measurement which should reach a precision similar to the two latest measurements, however, with a different method employing a precisely efficiency-calibrated germanium detector. As no method exists to greatly improve on previous results, the branching ratio has to be measured with independent methods.

  12. Using Item Response Theory to Develop Measures of Acquisitive and Protective Self-Monitoring From the Original Self-Monitoring Scale.

    Science.gov (United States)

    Wilmot, Michael P; Kostal, Jack W; Stillwell, David; Kosinski, Michal

    2017-07-01

    For the past 40 years, the conventional univariate model of self-monitoring has reigned as the dominant interpretative paradigm in the literature. However, recent findings associated with an alternative bivariate model challenge the conventional paradigm. In this study, item response theory is used to develop measures of the bivariate model of acquisitive and protective self-monitoring using original Self-Monitoring Scale (SMS) items, and data from two large, nonstudent samples ( Ns = 13,563 and 709). Results indicate that the new acquisitive (six-item) and protective (seven-item) self-monitoring scales are reliable, unbiased in terms of gender and age, and demonstrate theoretically consistent relations to measures of personality traits and cognitive ability. Additionally, by virtue of using original SMS items, previously collected responses can be reanalyzed in accordance with the alternative bivariate model. Recommendations for the reanalysis of archival SMS data, as well as directions for future research, are provided.

  13. Ethnicity and Health in Colombia: What Do Self-Perceived Health Indicators Tell Us?

    Science.gov (United States)

    Agudelo-Suárez, Andrés A; Martínez-Herrera, Eliana; Posada-López, Adriana; Rocha-Buelvas, Anderson

    2016-04-21

    To compare self-perceived health indicators between ethnic groups in Colombia. Cross-sectional study with data from the 2007 National Public Health Survey (ENSP-2007). Data from 57,617 people ≥18 years were used. Variables included: belonging to an ethnic group (exposure); self-rated health; mental health problems, injuries for accidents/violence (outcomes); sex, age, education level and occupation (explicative/control). A descriptive study was carried out of the explicative variables, and the prevalence of the outcomes was calculated according to ethnicity, education level and occupation. The association between the exposure variable and the outcomes was estimated by means of adjusted odds ratios (OR) with 95% CI using logistic regression. Analyses were conducted separately for men and women. The prevalence of outcomes was higher in people reporting to belong to an ethnic group and differences were found by sex, ethnic groups and health outcomes. Women from the Palenquero group were more likely to report poor self-rated health (aOR 7.04; 95%CI 2.50-19.88) and injuries from accidents/violence (aOR 7.99; 95%CI 2.89-22.07). Indigenous men were more likely to report mental health problems (aOR 1.75; 95%CI 1.41-2.17). Gradients according to ethnicity, education, occupation and sex were found. Minority ethnic groups are vulnerable to reporting poor health outcomes. Political actions are required to diminish health inequalities in these groups.

  14. Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

    Energy Technology Data Exchange (ETDEWEB)

    Conti, C.C., E-mail: ccconti@ird.gov.br [Institute for Radioprotection and Dosimetry – IRD/CNEN, Rio de Janeiro (Brazil); Physics Institute, State University of Rio de Janeiro – UERJ, Rio de Janeiro (Brazil); Anjos, M.J. [Physics Institute, State University of Rio de Janeiro – UERJ, Rio de Janeiro (Brazil); Salgado, C.M. [Nuclear Engineering Institute – IEN/CNEN, Rio de Janeiro (Brazil)

    2014-09-15

    Highlights: •This work describes a procedure for sample self-absorption correction. •The use of Monte Carlo simulation to calculate the mass attenuation coefficients curve was effective. •No need for transmission measurement, saving time, financial resources and effort. •This article provides de curves for the 90° scattering angle. •Calculation on-line at (www.macx.net.br). -- Abstract: X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at (www.macx.net.br)

  15. Associations between the Transsexual Voice Questionnaire (TVQMtF ) and self-report of voice femininity and acoustic voice measures.

    Science.gov (United States)

    Dacakis, Georgia; Oates, Jennifer; Douglas, Jacinta

    2017-11-01

    The Transsexual Voice Questionnaire (TVQ MtF ) was designed to capture the voice-related perceptions of individuals whose gender identity as female is the opposite of their birth-assigned gender (MtF women). Evaluation of the psychometric properties of the TVQ MtF is ongoing. To investigate associations between TVQ MtF scores and (1) self-perceptions of voice femininity and (2) acoustic parameters of voice pitch and voice quality in order to evaluate further the validity of the TVQ MtF . A strong correlation between TVQ MtF scores and self-ratings of voice femininity was predicted, but no association between TVQ MtF scores and acoustic measures of voice pitch and quality was proposed. Participants were 148 MtF women (mean age 48.14 years) recruited from the La Trobe Communication Clinic and the clinics of three doctors specializing in transgender health. All participants completed the TVQ MtF and 34 of these participants also provided a voice sample for acoustic analysis. Pearson product-moment correlation analysis was conducted to examine the associations between TVQ MtF scores and (1) self-perceptions of voice femininity and (2) acoustic measures of F0, jitter (%), shimmer (dB) and harmonic-to-noise ratio (HNR). Strong negative correlations between the participants' perceptions of their voice femininity and the TVQ MtF scores demonstrated that for this group of MtF women a low self-rating of voice femininity was associated with more frequent negative voice-related experiences. This association was strongest with the vocal-functioning component of the TVQ MtF . These strong correlations and high levels of shared variance between the TVQ MtF and a measure of a related construct provides evidence for the convergent validity of the TVQ MtF . The absence of significant correlations between the TVQ MtF and the acoustic data is consistent with the equivocal findings of earlier research. This finding indicates that these two measures assess different aspects of the voice

  16. Biodiversity Measurement Using Indices Based on Hyperspectral Reflectance on the Coast of Lagos

    Science.gov (United States)

    Omodanisi, E. O.; Salami, A. T.

    2013-12-01

    Hyperspectral measurements provide explicit measurements which can be used in the analysis of biodiversity change. This study was carried out in the coastal area of Lagos State, Nigeria. The objective of this study was to determine if gasoline seepage affects vegetation species distribution and reflectance; with the view to analyzing the vegetation condition. To evaluate the potential of different reflectance spectroscopy of species, the ASD Handheld2 Spectrometer was used. Three identified impacted plots of 30m by 30m were selected randomly and a control plot established in relatively undisturbed vegetated areas away from but perpendicular to the source of seepage. Each identified plot and the control consisted of five transects and measurement were taken at every 2m with about four reflectance measurement per sample point, to average out differences in reflectance as a result of different leaf angles. The radiance output of the spectrometer was converted into reflectance using the reflectance of a white reference over a standardized white spectralon panel. Indices such as Normalized Differential Vegetation Index, RedEdge Normalized Difference Vegetation Index, Soil Adjusted Vegetation Index, Ratio Vegetation Index and Volgelmann RedEdge Index 1 were calculated to accurately estimate the chlorophyll content in the vegetation within optimal band wavelength. Shannon-Weiner's index, Spearman's rank correlation and Analysis of Variance were used to analyze the data. Cocos nucifera was observed to be the most dominant species with a relative abundance of 47.27% while Ananas comosus recorded the lowest relative abundance of 21.8%. In the control plot, Cocos nucifera had the highest relative abundance of 42.3% and Mangifera indica with the least relative abundance of 16.7%. The relationship between the indices and chlorophyll content of the vegetation were significantly higher at (p>0.01) for all the indices in all the plots; however, RedEdgeNDVI and VOG1 indices had the

  17. Measurement of Tau Branching Ratios to Five Charged Hadrons

    CERN Document Server

    Ackerstaff, K.; Allison, John; Altekamp, N.; Anderson, K.J.; Anderson, S.; Arcelli, S.; Asai, S.; Ashby, S.F.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, Roger J.; Bartoldus, R.; Batley, J.R.; Baumann, S.; Bechtluft, J.; Behnke, T.; Bell, Kenneth Watson; Bella, G.; Bentvelsen, S.; Bethke, S.; Betts, S.; Biebel, O.; Biguzzi, A.; Bird, S.D.; Blobel, V.; Bloodworth, I.J.; Bobinski, M.; Bock, P.; Bohme, J.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brown, Robert M.; Burckhart, H.J.; Burgard, C.; Burgin, R.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Chrisman, D.; Ciocca, C.; Clarke, P.E.L.; Clay, E.; Cohen, I.; Conboy, J.E.; Cooke, O.C.; Couyoumtzelis, C.; Coxe, R.L.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Davis, R.; De Jong, S.; del Pozo, L.A.; De Roeck, A.; Desch, K.; Dienes, B.; Dixit, M.S.; Doucet, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Eatough, D.; Estabrooks, P.G.; Etzion, E.; Evans, H.G.; Fabbri, F.; Fanfani, A.; Fanti, M.; Faust, A.A.; Fiedler, F.; Fierro, M.; Fischer, H.M.; Fleck, I.; Folman, R.; Furtjes, A.; Futyan, D.I.; Gagnon, P.; Gary, J.W.; Gascon, J.; Gascon-Shotkin, S.M.; Geich-Gimbel, C.; Geralis, T.; Giacomelli, G.; Giacomelli, P.; Gibson, V.; Gibson, W.R.; Gingrich, D.M.; Glenzinski, D.; Goldberg, J.; Gorn, W.; Grandi, C.; Gross, E.; Grunhaus, J.; Gruwe, M.; Hanson, G.G.; Hansroul, M.; Hapke, M.; Hargrove, C.K.; Hartmann, C.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herndon, M.; Herten, G.; Heuer, R.D.; Hildreth, M.D.; Hill, J.C.; Hillier, S.J.; Hobson, P.R.; Hocker, James Andrew; Homer, R.J.; Honma, A.K.; Horvath, D.; Hossain, K.R.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Imrie, D.C.; Ishii, K.; Jacob, F.R.; Jawahery, A.; Jeremie, H.; Jimack, M.; Joly, A.; Jones, C.R.; Jovanovic, P.; Junk, T.R.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P.I.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Koetke, D.S.; Kokott, T.P.; Kolrep, M.; Komamiya, S.; Kowalewski, Robert V.; Kress, T.; Krieger, P.; von Krogh, J.; Kyberd, P.; Lafferty, G.D.; Lanske, D.; Lauber, J.; Lautenschlager, S.R.; Lawson, I.; Layter, J.G.; Lazic, D.; Lee, A.M.; Lefebvre, E.; Lellouch, D.; Letts, J.; Levinson, L.; Liebisch, R.; List, B.; Littlewood, C.; Lloyd, A.W.; Lloyd, S.L.; Loebinger, F.K.; Long, G.D.; Losty, M.J.; Ludwig, J.; Lui, D.; Macchiolo, A.; Macpherson, A.; Mannelli, M.; Marcellini, S.; Markopoulos, C.; Martin, A.J.; Martin, J.P.; Martinez, G.; Mashimo, T.; Mattig, Peter; McDonald, W.John; McKenna, J.; Mckigney, E.A.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Menke, S.; Merritt, F.S.; Mes, H.; Meyer, J.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mir, R.; Mohr, W.; Montanari, A.; Mori, T.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nellen, B.; Nisius, R.; O'Neale, S.W.; Oakham, F.G.; Odorici, F.; Ogren, H.O.; Oreglia, M.J.; Orito, S.; Palinkas, J.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Patt, J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poffenberger, P.; Poli, B.; Polok, J.; Przybycien, M.; Rembser, C.; Rick, H.; Robertson, S.; Robins, S.A.; Rodning, N.; Roney, J.M.; Roscoe, K.; Rossi, A.M.; Rozen, Y.; Runge, K.; Runolfsson, O.; Rust, D.R.; Sachs, K.; Saeki, T.; Sahr, O.; Sang, W.M.; Sarkisian, E.K.G.; Sbarra, C.; Schaile, A.D.; Schaile, O.; Scharf, F.; Scharff-Hansen, P.; Schieck, J.; Schmitt, B.; Schmitt, S.; Schoning, A.; Schorner, T.; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.P.; Sittler, A.; Skuja, A.; Smith, A.M.; Snow, G.A.; Sobie, R.; Soldner-Rembold, S.; Sproston, M.; Stahl, A.; Stephens, K.; Steuerer, J.; Stoll, K.; Strom, David M.; Strohmer, R.; Stumpf, L.; Tafirout, R.; Talbot, S.D.; Tanaka, S.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomson, M.A.; von Torne, E.; Torrence, E.; Towers, S.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turcot, A.S.; Turner-Watson, M.F.; Van Kooten, Rick J.; Vannerem, P.; Verzocchi, M.; Vikas, P.; Voss, H.; Wackerle, F.; Wagner, A.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wermes, N.; White, J.S.; Wilson, G.W.; Wilson, J.A.; Wyatt, T.R.; Yamashita, S.; Yekutieli, G.; Zacek, V.; Zer-Zion, D.

    1999-01-01

    The branching ratios of the decay of the tau lepton to five charged hadrons have been measured with the OPAL detector at LEP using data collected between 1991 and 1995 at e+e- centre-of-mass energies close to the Z resonance. The branching ratios are measured to be BR(tau- to 3h-2h+nutau) = 0.091+-0.014+-0.005% BR(tau- to 3h-2h+pi0nutau) = 0.027+-0.018+-0.007% where the first error is statistical and the second systematic.

  18. Linking local retention, self-recruitment, and persistence in marine metapopulations

    KAUST Repository

    Lett, Christophe

    2015-08-01

    Three indices of larval retention have been used in the literature to assess the tendency for self-maintenance of local marine populations: local retention (LR), self-recruitment (SR), and relative local retention (RLR). Only one of these, LR, defined as the ratio of locally produced settlement to local egg production, has a clear relationship to self-persistence of individual sites. However, SR, the ratio of locally produced settlement to settlement of all origins at a site, is generally easier to measure experimentally. We use theoretical, simulation, and empirical approaches to bridge the gap between these different indices, and demonstrate that there is a proportional relationship between SR and LR for metapopulations close to a stable state and with lifetime egg production (LEP) approximately uniform over space. Similarly, for systems where larval mortality rates are a relatively uniform function of release site, RLR (defined as the ratio of locally produced settlement to all settlement of local origin) and LR will also be proportional. Therefore, SR and RLR provide information on relative rates of LR for systems satisfying these conditions. Furthermore, the ratio between LR and SR can be used to evaluate global persistence of metapopulations, and therefore provides valuable information not necessarily available if only LR is considered.

  19. Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU

    Directory of Open Access Journals (Sweden)

    Deb Kumar Mojumder

    2015-01-01

    Full Text Available Introduction: Measurement of static pupillary size in the ICU is of importance in cases of acutely expanding intracranial mass lesions. The inaccuracies with subjective assessment of pupillary size by medical personnel preclude its use in emergent neurological situations. Objective: To determine if the ratio of pupil to limbus diameter (PLD ratio measured by a two-box method is a reliable measure of pupil size for detecting early anisocoria and measuring pupillary changes. Materials and Methods: The PLD ratio was defined as the ratio of the pupillary diameter measured at a para-horizontal axial plane with the limbus diameter measured at the same or parallel axial plane. A two-box method was used to estimate the diameters of imaged pupils. Eyes were imaged using an iPhone 4S cellphone camera. Background illumination was measured and kept constant. The pupils of a 78-year-old woman, who presented with a large intra-axial parenchymal hemorrhage, were imaged. The patient had left pupillary miosis in dark but not in bright light. After presenting this case along with the images of the pupillary examination, a group of 21 medical staff were asked several questions on the pupillary examination. Reliability of PLD ratio were assessed via standard error of mean (S.E.M of PLD ratios for 3 different subjects each imaged under constant illumination and fixation but from different angles to the optical axis. Results: Analysis of questionnaire data together with PLD ratios revealed that ~ 14% and 10% of participants could estimate the pupillary size in darkness and bright light respectively but none were simultaneously accurate indicating that subjective assessment of pupillary size was unreliable. The approach towards a systematic pupillary examination was inconsistent among the participants. The PLD ratio was found to be a reliable measure of pupillary size with standard error of mean below 0.1 mm for the three subjects tested. Conclusion: Static pupillary

  20. Estimation of (n,f) Cross-Sections by Measuring Reaction Probability Ratios

    Energy Technology Data Exchange (ETDEWEB)

    Plettner, C; Ai, H; Beausang, C W; Bernstein, L A; Ahle, L; Amro, H; Babilon, M; Burke, J T; Caggiano, J A; Casten, R F; Church, J A; Cooper, J R; Crider, B; Gurdal, G; Heinz, A; McCutchan, E A; Moody, K; Punyon, J A; Qian, J; Ressler, J J; Schiller, A; Williams, E; Younes, W

    2005-04-21

    Neutron-induced reaction cross-sections on unstable nuclei are inherently difficult to measure due to target activity and the low intensity of neutron beams. In an alternative approach, named the 'surrogate' technique, one measures the decay probability of the same compound nucleus produced using a stable beam on a stable target to estimate the neutron-induced reaction cross-section. As an extension of the surrogate method, in this paper they introduce a new technique of measuring the fission probabilities of two different compound nuclei as a ratio, which has the advantage of removing most of the systematic uncertainties. This method was benchmarked in this report by measuring the probability of deuteron-induced fission events in coincidence with protons, and forming the ratio P({sup 236}U(d,pf))/P({sup 238}U(d,pf)), which serves as a surrogate for the known cross-section ratio of {sup 236}U(n,f)/{sup 238}U(n,f). IN addition, the P({sup 238}U(d,d{prime}f))/P({sup 236}U(d,d{prime}f)) ratio as a surrogate for the {sup 237}U(n,f)/{sup 235}U(n,f) cross-section ratio was measured for the first time in an unprecedented range of excitation energies.

  1. Investigation of grapevine photosynthesis using hyperspectral techniques and development of hyperspectral band ratio indices sensitive to photosynthesis.

    Science.gov (United States)

    Ozelkan, Emre; Karaman, Muhittin; Candar, Serkan; Coskun, Zafer; Ormeci, Cankut

    2015-01-01

    The photosynthetic rate of 9 different grapevines were analyzed with simultaneous photosynthesis and spectroradiometric measurements on 08.08.2012 (veraison) and 06.09.2012 (harvest). The wavelengths and spectral regions, which most properly express photosynthetic rate, were determined using correlation and regression analysis. In addition, hyperspectral band ratio (BR) indices sensitive to photosynthesis were developed using optimum band ratio (OBRA) method. The relation of BR results with photosynthesis values are presented with the correlation matrix maps created in this study. The examinations were performed for both specific dates (i.e., veraison and harvest) and also in aggregate (i.e., correlation between total spectra and photosynthesis data). For specific dates wavelength based analysis, the photosynthesis were best determined with -0.929 correlation coefficient (r) 609 nm of yellow region at veraison stage, and -0.870 at 641 nm of red region at harvest stage. For wavelength based aggregate analysis, 640 nm of red region was found to be correlated with 0.921 and -0.867 r values respectively and red edge (RE) (695 nm) was found to be correlated with -0.922 and -0.860 r values, respectively. When BR indices results were analyzed with photosynthetic values for specific dates, -0.987 r with R8../R, at veraison stage and -0.911 r with R696/R944 at harvest stage were found most correlated. For aggregate analysis of BR, common BR presenting great correlation with photosynthesis for both measurements was found to be R632/R971 with -0.974, -0.881 r values, respectively and other R610/R760 with -0.976, -0.879 r values. The final results of this study indicate that the proportion of RE region to a region with direct or indirect correlation with photosynthetic provides information about rate of photosynthesis. With the indices created in this study, the photosynthesis rate of vineyards can be determined using in-situ hyperspectral remote sensing. The findings of this

  2. Measuring self-esteem in dieting disordered patients: the validity of the Rosenberg and Coopersmith contrasted.

    Science.gov (United States)

    Griffiths, R A; Beumont, P J; Giannakopoulos, E; Russell, J; Schotte, D; Thornton, C; Touyz, S W; Varano, P

    1999-03-01

    In order to ascertain the most appropriate measure of self-esteem for dieting disordered patients, this study contrasted the construct and convergent validities of two widely used measures. In addition, dieting disordered subgroups were compared on levels of self-esteem. One hundred and seventeen male and female patients diagnosed with anorexia nervosa, bulimia nervosa, or eating disorder not otherwise specified completed the Rosenberg Self-Esteem Scale (SES), the Coopersmith Self-Esteem Inventory (SEI), and measures of dieting disorder pathology and depression. No significant differences among the three dieting disorder subgroups were found. In determining convergent validity, regression analyses indicated that the SES was a significant predictor of dieting disorder psychopathology whereas the SEI was not. Of the two self-esteem measures, only the SES showed evidence of convergent validity. The results suggest that the SES has sounder construct and convergent validity than the SEI. Hence, the SES may be more appropriate for use with dieting disordered populations.

  3. High Precision Measurement of the Proton Elastic Form Factor Ratio at Low Q2

    Energy Technology Data Exchange (ETDEWEB)

    Zhan, Xiaohui [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2010-01-01

    Experiment E08-007 measured the proton elastic form factor ratio μpGE/GM in the range of Q2 = 0.3-0.7(GeV/c)2 by recoil polarimetry. Data were taken in 2008 at the Thomas Jefferson National Accelerator Facility in Virginia, USA. A 1.2 GeV polarized electron beam was scattered off a cryogenic hydrogen target. The recoil proton was detected in the left HRS in coincidence with the elasticly scattered electrons tagged by the BigBite spectrometer. The proton polarization was measured by the focal plane polarimeter (FPP). In this low Q2 region, previous measurement from Jefferson Lab Hall A (LEDEX) along with various fits and calculations indicate substantial deviations of the ratio from unity. For this new measurement, the proposed statistical uncertainty (< 1%) was achieved. These new results are a few percent lower than expected from previous world data and fits, which indicate a smaller GEp at this region. Beyond the intrinsic interest in nucleon structure, the new results also have implications in determining the proton Zemach radius and the strangeness form factors from parity violation experiments.

  4. Is Waist-to-Height Ratio a Better Obesity Risk-Factor Indicator for Puerto Rican Children than is BMI or Waist Circumference?

    Science.gov (United States)

    Rivera-Soto, Winna T; Rodríguez-Figueroa, Linnette

    2016-03-01

    Puerto Rican children could have a higher prevalence of obesity, compared to US children or even to US Hispanic children. Obese youths are more likely to have risk factors for cardiovascular conditions, such as hypertension. Although BMI provides a simple, convenient measurement of obesity, it does not measure body fat distribution, associated with mortality and morbidity. Waist circumference (WC) and waist-to-height ratio (WHtR) have been suggested to estimate obesity health risks. This study aimed to explore the association of a single blood pressure reading with 3 different obesity indicators (WC, BMI, and WHtR). A representative sample of students (first to sixth grade) from public and private schools in Puerto Rico was selected. The sample size consisted of 249 students, representing a 63% response rate. According to the sex-specific BMIs, approximately 38.1% of the children were obese or overweight. The prevalence of obesity was slightly higher when determined using WHtR but lower when using WC as the overweight indicator. The prevalence of high blood pressure among students was 12.5%; an additional 11.3% of the students were classified as possible prehypertensive. Regardless of the weight indicator used, overweight children were shown to have a higher risk of pre-hypertension/hypertension (as defined by a single BP measure) than were non-overweight children. The odds for high blood pressure were almost 3 times higher using WHtR. Logistic regression showed a stronger relationship between WHtR and the risk of pre-hypertension/hypertension than that between the former and either BMI or WC. This study suggests the possibility of higher prevalence of high blood pressure in obese Puerto Rican children. The waist-to height ratio could be the best indicator to measure obesity and potential hypertension in Puerto Rican children.

  5. Hope and General Self-efficacy: Two Measures of the Same Construct?

    Science.gov (United States)

    Zhou, Mingming; Kam, Chester Chun Seng

    2016-07-03

    The aim of this study was to test the extent to which hope measure is equivalent to general self-efficacy measure. Questionnaire data on these two constructs and other external variables were collected from 199 Chinese college students. The factor analytic results suggested that hope and self-efficacy items measured the same construct. The unidimensional model combining hope items and GSE items fit the data as well as the bidimensional model, indicating that their corresponding items measured the same underlying construct. Further analyses showed that hope and GSE did not correlate with external variables differently in a systematic manner. Most of these correlational differences were non-significant and negligible. These findings suggested that the literatures studying GSE and hope could be considered to be integrated and that researchers need to recognize and acknowledge the conceptual and operational similarities among these constructs in the literature.

  6. Self-informant Agreement for Personality and Evaluative Person Descriptors: Comparing Methods for Creating Informant Measures.

    Science.gov (United States)

    Simms, Leonard J; Zelazny, Kerry; Yam, Wern How; Gros, Daniel F

    2010-05-01

    Little attention typically is paid to the way self-report measures are translated for use in self-informant agreement studies. We studied two possible methods for creating informant measures: (a) the traditional method in which self-report items were translated from the first- to the third-person and (b) an alternative meta-perceptual method in which informants were directed to rate their perception of the targets' self-perception. We hypothesized that the latter method would yield stronger self-informant agreement for evaluative personality dimensions measured by indirect item markers. We studied these methods in a sample of 303 undergraduate friendship dyads. Results revealed mean-level differences between methods, similar self-informant agreement across methods, stronger agreement for Big Five dimensions than for evaluative dimensions, and incremental validity for meta-perceptual informant rating methods. Limited power reduced the interpretability of several sparse acquaintanceship effects. We conclude that traditional informant methods are appropriate for most personality traits, but meta-perceptual methods may be more appropriate when personality questionnaire items reflect indirect indicators of the trait being measured, which is particularly likely for evaluative traits.

  7. Self-control, future orientation, smoking, and the impact of Dutch tobacco control measures.

    Science.gov (United States)

    Daly, Michael; Delaney, Liam; Baumeister, Roy F

    2015-06-01

    The pronounced discrepancy between smokers' intentions to quit and their smoking behavior has led researchers to suggest that many smokers are time inconsistent, have self-control problems, and may benefit from external efforts to constrain their consumption. This study aims to test whether self-control and future orientation predict smoking levels and to identify if these traits modify how cigarette consumption responds to the introduction of tobacco control measures. A sample of Dutch adults (N = 1585) completed a measure of self-control and the Consideration of Future Consequences Scale (CFCS) in 2001 and indicated their tobacco consumption each year from 2001 to 2007. In 2004, a workplace smoking ban and substantial tax increase on tobacco was introduced in the Netherlands. To identify the potential impact of these tobacco control measures we examined whether participants smoked or were heavy smokers (20 + cigarettes per day) each year from 2001 to 2007. Participants with high self-control and CFCS scores showed lower rates of smoking across the seven year period of the study. The 2004 smoking restrictions were linked with a subsequent decline in heavy smoking. This decline was moderated by self-control levels. Those with low self-control showed a large reduction in heavy smoking whereas those with high self-control did not. The effects were, however, temporary: many people with low self-control resumed heavy smoking 2-3 years after the introduction of the tobacco restrictions. The immediate costs which national tobacco control measures impose on smokers may assist smokers with poor self-control in reducing their cigarette consumption.

  8. Associations between self-estimated and measured physical fitness among 40-year-old men and women.

    Science.gov (United States)

    Mikkelsson, L; Kaprio, J; Kautiainen, H; Kujala, U M; Nupponen, H

    2005-10-01

    The aim was to evaluate whether 40-year-old men and women are able to estimate their level of fitness compared with actual measured physical fitness. Twenty-nine men and 35 women first completed a questionnaire at home and then their physical fitness was measured at laboratory. The index of self-estimated physical fitness was calculated by summing up the scores of self-estimated endurance, strength, speed and flexibility. The index of self-estimated endurance was calculated by summing up the scores of self-estimated endurance and those of the self-estimated distance they could run, cycle, ski and walk. The index of measured physical fitness was calculated by summing up the z-scores of a submaximal bicycle ergometer test, ergojump tests (counter-movement jump and jumping in 15 s), a 30-s sit-up test, hand-grip tests and a sit-and-reach test. The correlation (Spearman) between the indices of self-estimated and measured physical fitness was 0.54 for both sexes, and that between self-estimated endurance and measured endurance was 0.53 for both sexes. Maximal oxygen uptake estimated based on submaximal ergometer test was higher among those with longer self-estimated distance of running, cycling, skiing and walking (P for linear trend ski or walk. However, in some individuals self-estimation of fitness is not in agreement with the results of fitness tests.

  9. Indications of a Scarring Effect of Sickness Absence Periods in a Cohort of Higher Educated Self-Employed

    Science.gov (United States)

    Wijnvoord, Liesbeth E. C.; Brouwer, Sandra; Buitenhuis, Jan; van der Klink, Jac J. L.; de Boer, Michiel R.

    2016-01-01

    Objectives Little is known regarding incidence and recurrence of sickness absence in self-employed. The primary aim of this study was to evaluate the influence of the number of prior episodes of sickness absence on the risk of subsequent periods of sickness absence in higher educated self-employed. Methods In a historic register study based on the files of a Dutch private disability insurance company all sickness absence periods of 30 days or more were analysed. Results A total of 15,868 insured persons contributed 141,188 person years to the study. In total, 5608 periods of sickness absence occurred during follow-up. The hazard of experiencing a new period of sickness absence increased with every previous period, ranging from a hazard ratio of 2.83 in case of one previous period of sickness absence to a hazard ratio of 6.72 in case of four previous periods. This effect was found for both men and women and for all diagnostic categories of the first period of sickness absence. Conclusions Our study shows that for all diagnostic categories the hazard of experiencing a recurrence of sickness absence is appreciably higher than for experiencing a first episode. This suggests that this increased hazard may be related to the occurrence of sickness absence itself rather than related to characteristics of the insured person or of the medical condition. These findings could indicate that sickness absence periods may have a scarring effect on the self-employed person experiencing the sickness absence. PMID:27213963

  10. Simultaneous measurement of quantum yield ratio and absorption ratio between acceptor and donor by linearly unmixing excitation-emission spectra.

    Science.gov (United States)

    Zhang, C; Lin, F; DU, M; Qu, W; Mai, Z; Qu, J; Chen, T

    2018-02-13

    Quantum yield ratio (Q A /Q D ) and absorption ratio (K A /K D ) in all excitation wavelengths used between acceptor and donor are indispensable to quantitative fluorescence resonance energy transfer (FRET) measurement based on linearly unmixing excitation-emission spectra (ExEm-spFRET). We here describe an approach to simultaneously measure Q A /Q D and K A /K D values by linearly unmixing the excitation-emission spectra of at least two different donor-acceptor tandem constructs with unknown FRET efficiency. To measure the Q A /Q D and K A /K D values of Venus (V) to Cerulean (C), we used a wide-field fluorescence microscope to image living HepG2 cells separately expressing each of four different C-V tandem constructs at different emission wavelengths with 435 nm and 470 nm excitation respectively to obtain the corresponding excitation-emission spectrum (S DA ). Every S DA was linearly unmixed into the contributions (weights) of three excitation-emission spectra of donor (W D ) and acceptor (W A ) as well as donor-acceptor sensitisation (W S ). Plot of W S /W D versus W A /W D for the four C-V plasmids from at least 40 cells indicated a linear relationship with 1.865 of absolute intercept (Q A /Q D ) and 0.273 of the reciprocal of slope (K A /K D ), which was validated by quantitative FRET measurements adopting 1.865 of Q A /Q D and 0.273 of K A /K D for C32V, C5V, CVC and VCV constructs respectively in living HepG2 cells. © 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.

  11. Comparing Self-Report Measures of Internalized Weight Stigma: The Weight Self-Stigma Questionnaire versus the Weight Bias Internalization Scale.

    Directory of Open Access Journals (Sweden)

    Claudia Hübner

    Full Text Available Internalized weight stigma has gained growing interest due to its association with multiple health impairments in individuals with obesity. Especially high internalized weight stigma is reported by individuals undergoing bariatric surgery. For assessing this concept, two different self-report questionnaires are available, but have never been compared: the Weight Self-Stigma Questionnaire (WSSQ and the Weight Bias Internalization Scale (WBIS. The purpose of the present study was to provide and to compare reliability, convergent validity with and predictive values for psychosocial health outcomes for the WSSQ and WBIS.The WSSQ and the WBIS were used to assess internalized weight stigma in N = 78 prebariatric surgery patients. Further, body mass index (BMI was assessed and body image, quality of life, self-esteem, depression, and anxiety were measured by well-established self-report questionnaires. Reliability, correlation, and regression analyses were conducted.Internal consistency of the WSSQ was acceptable, while good internal consistency was found for the WBIS. Both measures were significantly correlated with each other and body image. While only the WSSQ was correlated with overweight preoccupation, only the WBIS was correlated with appearance evaluation. Both measures were not associated with BMI. However, correlation coefficients did not differ between the WSSQ and the WBIS for all associations with validity measures. Further, both measures significantly predicted quality of life, self-esteem, depression, and anxiety, while the WBIS explained significantly more variance than the WSSQ total score for self-esteem.Findings indicate the WSSQ and the WBIS to be reliable and valid assessments of internalized weight stigma in prebariatric surgery patients, although the WBIS showed marginally more favorable results than the WSSQ. For both measures, longitudinal studies on stability and predictive validity are warranted, for example, for weight

  12. The Lifespan Self-Esteem Scale: Initial Validation of a New Measure of Global Self-Esteem.

    Science.gov (United States)

    Harris, Michelle A; Donnellan, M Brent; Trzesniewski, Kali H

    2018-01-01

    This article introduces the Lifespan Self-Esteem Scale (LSE), a short measure of global self-esteem suitable for populations drawn from across the lifespan. Many existing measures of global self-esteem cannot be used across multiple developmental periods due to changes in item content, response formats, and other scale characteristics. This creates a need for a new lifespan scale so that changes in global self-esteem over time can be studied without confounding maturational changes with alterations in the measure. The LSE is a 4-item measure with a 5-point response format using items inspired by established self-esteem scales. The scale is essentially unidimensional and internally consistent, and it converges with existing self-esteem measures across ages 5 to 93 (N = 2,714). Thus, the LSE appears to be a useful measure of global self-esteem suitable for use across the lifespan as well as contexts where a short measure is desirable, such as populations with short attention spans or large projects assessing multiple constructs. Moreover, the LSE is one of the first global self-esteem scales to be validated for children younger than age 8, which provides the opportunity to broaden the field to include research on early formation and development of global self-esteem, an area that has previously been limited.

  13. Extinction-to-Backscatter Ratios of Saharan Dust Layers Derived from In-Situ Measurements and CALIPSO Overflights During NAMMA

    Science.gov (United States)

    Omar, Ali H.; Liu, Zhaoyan; Vaughan, Mark A.; Hu, Yongxiang; Ismail, Syed; Powell, Kathleen A.; Winker, David M.; Trepte, Charles R.; Anderson, Bruce E.

    2010-01-01

    We determine the aerosol extinction-to-backscatter (Sa) ratios of dust using airborne in-situ measurements of microphysical properties, and CALIPSO observations during the NASA African Monsoon Multidisciplinary Analyses (NAMMA). The NAMMA field experiment was conducted from Sal, Cape Verde during Aug-Sept 2006. Using CALIPSO measurements of the attenuated backscatter of lofted Saharan dust layers, we apply the transmittance technique to estimate dust Sa ratios at 532 nm and a 2-color method to determine the corresponding 1064 nm Sa. Using this method, we found dust Sa ratios of 39.8 plus or minus 1.4 sr and 51.8 plus or minus 3.6 sr at 532 nm and 1064 nm, respectively. Secondly, Sa ratios at both wavelengths is independently calculated using size distributions measured aboard the NASA DC-8 and estimates of Saharan dust complex refractive indices applied in a T-Matrix scheme. We found Sa ratios of 39.1 plus or minus 3.5 sr and 50.0 plus or minus 4 sr at 532 nm and 1064 nm, respectively, using the T-Matrix calculations applied to measured size spectra. Finally, in situ measurements of the total scattering (550 nm) and absorption coefficients (532 nm) are used to generate an extinction profile that is used to constrain the CALIPSO 532 nm extinction profile.

  14. Biological markers of asexuality: Handedness, birth order, and finger length ratios in self-identified asexual men and women.

    Science.gov (United States)

    Yule, Morag A; Brotto, Lori A; Gorzalka, Boris B

    2014-02-01

    Human asexuality is defined as a lack of sexual attraction to anyone or anything and it has been suggested that it may be best conceptualized as a sexual orientation. Non-right-handedness, fraternal birth order, and finger length ratio (2D:4D) are early neurodevelopmental markers associated with sexual orientation. We conducted an Internet study investigating the relationship between self-identification as asexual, handedness, number of older siblings, and self-measured finger-lengths in comparison to individuals of other sexual orientation groups. A total of 325 asexuals (60 men and 265 women; M age, 24.8 years), 690 heterosexuals (190 men and 500 women; M age, 23.5 years), and 268 non-heterosexuals (homosexual and bisexual; 64 men and 204 women; M age, 29.0 years) completed online questionnaires. Asexual men and women were 2.4 and 2.5 times, respectively, more likely to be non-right-handed than their heterosexual counterparts and there were significant differences between sexual orientation groups in number of older brothers and older sisters, and this depended on handedness. Asexual and non-heterosexual men were more likely to be later-born than heterosexual men, and asexual women were more likely to be earlier-born than non-heterosexual women. We found no significant differences between sexual orientation groups on measurements of 2D:4D ratio. This is one of the first studies to test and provide preliminary empirical support for an underlying neurodevelopmental basis to account for the lack of sexual attraction characteristic of asexuality.

  15. [Comparison study on subjective and objective measurements of the accommodative convergence to accommodation ratio].

    Science.gov (United States)

    Xu, Jing-jing; Xu, Dan; Huang, Tao; Jiang, Jian; Lü, Fan

    2012-05-01

    To detect the accommodative convergence to accommodation (AC/A) ratios measured respectively by objective and subjective methods. The differences and its relative factors were explored. Forty young volunteers were measured by eye tracker to get the amount of convergence when fixating at the target at 100 cm, 50 cm, 33 cm and 25 cm and were measured by infrared auto-refractor to get corresponding accommodative responses. AC/A ratio based on these two measurements were compared with the calculated and the gradient AC/A ratio from Von Graefe tests. Mean value of stimulated AC/A ratio measured by eye tracker was higher than the calculated and gradient AC/A ratio by Von Graefe method (P = 0.003, 0.001). There are statistic correlation (r = 0.871, P = 0.000) and difference (P = 0.000) between stimulated AC/A ratio and response AC/A ratios both measured by eye tracker, and the difference trends to be greater with the higher AC/A ratio. The objective AC/A ratio is usually higher than the clinical subjective measurement because of more proximal effect. The response AC/A ratio measured objectively may reveal realistically the mutual effect and relationship between accommodation and convergence and it seems to be more credible to be the monitor parameter on progression of myopia in clinics.

  16. A Time-Measurement System Based on Isotopic Ratios

    International Nuclear Information System (INIS)

    Vo, Duc T.; Karpius, P.J.; MacArthur, D.W.; Thron, J.L.

    2007-01-01

    A time-measurement system can be built based on the ratio of gamma-ray peak intensities from two radioactive isotopes. The ideal system would use a parent isotope with a short half-life decaying to a long half-life daughter. The activities of the parent-daughter isotopes would be measured using a gamma-ray detector system. The time can then be determined from the ratio of the activities. The best-known candidate for such a system is the 241 Pu- 241 Am parent-daughter pair. However, this 241 Pu- 241 Am system would require a high-purity germanium detector system and sophisticated software to separate and distinguish between the many gamma-ray peaks produced by the decays of the two isotopes. An alternate system would use two different isotopes, again one with a short half-life and one with a half-life that is long relative to the other. The pair of isotopes 210 Pb and 241 Am (with half-lives of 22 and 432 years, respectively) appears suitable for such a system. This time-measurement system operates by measuring the change in the ratio of the 47-keV peak of 210 Pb to the 60-keV peak of 241 Am. For the system to work reasonably well, the resolution of the detector would need to be such that the two gamma-ray peaks are well separated so that their peak areas can be accurately determined using a simple region-of-interest (ROI) method. A variety of detectors were tested to find a suitable system for this application. The results of these tests are presented here.

  17. The prospect for fuel ion ratio measurements in ITER by collective Thomson scattering

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Korsholm, Søren Bang; Nielsen, Stefan Kragh

    2012-01-01

    We show that collective Thomson scattering (CTS) holds the potential to become a new diagnostic principle for measurements of the fuel ion ratio, nT/nD, in ITER. Fuel ion ratio measurements will be important for plasma control and machine protection in ITER. Measurements of ion cyclotron structures...... in CTS spectra have been suggested as the basis for a new fuel ion ratio diagnostic which would be well suited for reactor environments and capable of providing spatially resolved measurements in the plasma core. Such measurements were demonstrated in recent experiments in the TEXTOR tokamak. Here we...... conduct a sensitivity study to investigate the potential measurement accuracy of a CTS fuel ion ratio diagnostic on ITER. The study identifies regions of parameter space in which CTS can be expected to provide useful information on plasma composition, and we find that a CTS fuel ion ratio diagnostic could...

  18. Detecting rapid mass movements using electrical self-potential measurements

    Science.gov (United States)

    Heinze, Thomas; Limbrock, Jonas; Pudasaini, Shiva P.; Kemna, Andreas

    2017-04-01

    results indicate that electrical self-potential measurements can observe rapid mass movements when the movement is large and fast enough to disturb the fluid pressure field significantly.

  19. Measurement of stable isotope ratio of organic carbon in water samples

    International Nuclear Information System (INIS)

    Fujii, Toshihiro; Otsuki, Akira

    1977-01-01

    A new method for the measurement of stable isotope ratios was investigated and applied to organic carbon's isotope ratio measurements in water samples. A few river water samples from Tsuchiura city were tested. After the wet oxidation of organic carbons to carbon dioxide in a sealed ampoule, the isotope ratios were determined with the gas chromatograph-quadrupole mass spectrometer combined with a total organic carbon analyser, under the dynamic conditions. The GC-MS had been equipped with the multiple ion detector-digital integrator system. The ion intensities at m/e 44 and 45 were simultaneously measured at a switching rate of 1 ms. The measurements with carbon dioxide acquired from sodium carbonate (53 μg) gave the isotope ratios with the variation coefficient of 0.62%. However, the variation coefficients obtained from organic carbons in natural water samples were 2 to 3 times as high as that from sodium carbonate. This method is simple and rapid and may be applied to various fields especially in biology and medicine. (auth.)

  20. Nonsuicidal Self-Injury: Relationship to Behavioral and Self-Rating Measures of Impulsivity and Self-Aggression

    Science.gov (United States)

    Mc Closkey, Michael S.; Look, Amy E.; Chen, Eunice Y.; Pajoumand, Golnaz; Berman, Mitchell E.

    2012-01-01

    Previous research using self-report measures has shown an association between nonsuicidal self-injurious behavior (NSSI) and impulsive tendencies. However, self-injurers have not been shown to be different from comparison groups on laboratory tasks putatively assessing impulsive behavior. One explanation for these contradictory findings is that…

  1. Waist-to-Height Ratio in Indian Women: Comparison With Traditional Indices of Obesity, Association With Inflammatory Biomarkers and Lipid Profile.

    Science.gov (United States)

    Dilip Malshe, Sharvari; Anand Udipi, Shobha

    2017-07-01

    We compared waist-to-height ratio (WHtR) with traditional anthropometric indices in healthy women aged 21 to 45 years from urban slums of Mumbai city, India. Lipid profile and inflammatory markers were measured in a subsample of 200 women, and their relationship with WHtR was examined. Mean WHtR was 0.50 ± 0.1, but a little more than half (51.9%) of the women had WHtR ≥0.50. WHtR could correctly identify centrally obese adult women, even when they were categorized as healthy or normal according to body mass index, waist circumference, waist to hip ratio, and percentage body fat. Also, in centrally obese women, inflammatory markers-namely, high-sensitivity C-reactive protein, interleukin-6, and interleukin-10-were significantly and positively correlated with WHtR. Thus, results of this study indicate that WHtR is a simple and effective anthropometric variable that has the potential to identify central obesity and the associated inflammation even in women with normal BMI.

  2. Creating a measure of portion control self-efficacy.

    Science.gov (United States)

    Fast, Lindsey C; Harman, Jennifer J; Maertens, Julie A; Burnette, Jeni L; Dreith, Francesca

    2015-01-01

    Over the last few decades, food portion sizes have steadily increased by as much as 700% (Young & Nestle, 2002). Food portions are often much larger than dietary guidelines recommend, leaving individuals to manage their food consumption on their own and making it necessary to understand individual factors impacting food consumption. In the current paper, we focus on self-efficacy for portion control. Specifically, across three studies, we developed and validated a new measure of portion control self-efficacy (PCSE). The PCSE measure yielded good fit statistics and had acceptable test-retest reliability using two cross-sectional surveys (Studies 1(a) and 1(b)). Results from Study 2 demonstrated construct and predictive validity of the PCSE using the Food Amount Rating Scale (FARS; Dohm, & Striegel-Moore, 2002). Study 3 offered additional support for reliability and validity with a sample of overweight and obese adults currently trying to lose weight. Overall, findings indicate that the new PCSE measure is reliable and valid. Individuals often make inaccurate food portion estimates (Slawson & Eck, 1997; Yuhas, Bolland, & Bolland, 1989) which can lead to overeating and weight-gain. Thus, the discussion centers on the need to incorporate PCSE in future research and intervention work targeting weight loss, health, and food consumption. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. How low is low? Low self-esteem as an indicator of internalizing psychopathology in adolescence.

    Science.gov (United States)

    Isomaa, Rasmus; Väänänen, Juha-Matti; Fröjd, Sari; Kaltiala-Heino, Riittakerttu; Marttunen, Mauri

    2013-08-01

    Schools are among the most important setting for preventive interventions among adolescents. There are evidence-based intervention programs for adolescents at risk for and with early signs of mental health problems but one demanding task is to detect the ones who are in need of an intervention. The aim of the present study was to analyze associations between self-esteem, depressive symptoms, and social anxiety in order to determine clinically relevant cut-points for male and female adolescents' self-esteem as measured with the Rosenberg Self-Esteem Scale (RSES). The participants of the present prospective study, started in 2002-2003, were 2070 adolescents aged 15 years (1,167 girls and 903 boys) at two study sites in Finland who participated at both baseline and 2-year follow-up. Self-esteem was related to depressive symptoms and social anxiety, and the RSES was able to discriminate between cases of depression and social phobia. The present study suggests a cutoff of 25 points to classify low self-esteem in both girls and boys. Low self-esteem may function as an indicator of various forms of internalizing psychopathology. The RSES is worth further examination as a potential screening tool for adolescents in risk of psychopathology.

  4. Self-Criticism: A Measure of Uncompassionate Behaviors Toward the Self, Based on the Negative Components of the Self-Compassion Scale.

    Science.gov (United States)

    Montero-Marín, Jesús; Gaete, Jorge; Demarzo, Marcelo; Rodero, Baltasar; Lopez, Luiz C Serrano; García-Campayo, Javier

    2016-01-01

    The use of the Self-Compassion Scale (SCS) as a single measure has been pointed out as problematic by many authors and its originally proposed structure has repeatedly been called into question. The negative facets of this construct are more strongly related to psychopathology than the positive indicators. The aim of this study was to evaluate and compare the different structures proposed for the SCS, including a new measure based only on the negative factors, and to assess the psychometric features of the more plausible solution. The study employed a cross-sectional and cross-cultural design. A sample of Brazilian (n = 406) and Spanish (n = 416) primary care professionals completed the SCS, and other questionnaires to measure psychological health-related variables. The SCS factor structure was estimated using confirmatory factor analysis by the maximum likelihood method. Internal consistency was assessed by squaring the correlation between the latent true variable and the observed variables. The relationships between the SCS and other constructs were analyzed using Spearman's r s . The structure with the best fit was comprised of the three negative first-order factors of "self-judgment", "isolation" and "over-identification", and one negative second-order factor, which has been named "self-criticism" [CFI = 0.92; RMSEA = 0.06 (90% CI = 0.05-0.07); SRMR = 0.05]. This solution was supported by both samples, presented partial metric invariance [CFI = 0.91; RMSEA = 0.06 (90% CI = 0.05-0.06); SRMR = 0.06], and showed significant correlations with other health-related psychological constructs. Reliability was adequate for all the dimensions (R ≥ 0.70). The original structure proposed for the SCS was not supported by the data. Self-criticism, comprising only the negative SCS factors, might be a measure of uncompassionate behaviors toward the self, with good psychometric properties and practical implications from a clinical point of view, reaching a stable structure and

  5. Self-criticism: a measure of uncompassionate behaviours towards the self, based on the negative components of the Self-Compassion Scale

    Directory of Open Access Journals (Sweden)

    Jesus Montero-Marin

    2016-08-01

    Full Text Available Background: The use of the Self-Compassion Scale (SCS as a single measure has been pointed out as problematic by many authors and its originally proposed structure has repeatedly been called into question. The negative facets of this construct are more strongly related to psychopathology than the positive indicators. The aim of this study was to evaluate and compare the different structures proposed for the SCS, including a new measure based only on the negative factors, and to assess the psychometric features of the more plausible solution.Method: The study employed a cross-sectional and cross-cultural design. A sample of Brazilian (n=406 and Spanish (n=416 primary care professionals completed the SCS, and other questionnaires to measure psychological health-related variables. The SCS factor structure was estimated using confirmatory factor analysis by the maximum likelihood method. Internal consistency was assessed by squaring the correlation between the latent true variable and the observed variables. The relationships between the SCS and other constructs were analysed using Spearman’s R.Results: The structure with the best fit was comprised of the three negative first-order factors of ‘self-judgement’, ‘isolation’ and ‘over-identification’, and one negative second-order factor, which has been named ‘self-criticism’ [CFI=0.92; RMSEA=0.06 (90% CI=0.05-0.07; SRMR=0.05]. This solution was supported by both samples, presented partial metric invariance [CFI=0.91; RMSEA=0.06 (90% CI=0.05-0.06; SRMR=0.06], and showed significant correlations with other health-related psychological constructs. Reliability was adequate for all the dimensions (R≥0.70. Conclusions: The original structure proposed for the SCS was not supported by the data. Self-criticism, comprising only the negative SCS factors, might be a measure of uncompassionate behaviours towards the self, with good psychometric properties and practical implications from a

  6. Measurement of the atmospheric muon charge ratio with the OPERA detector

    CERN Document Server

    Agafonova, N.; Aoki, S.; Ariga, A.; Ariga, T.; Autiero, D.; Badertscher, A.; Bagulya, A.; Bertolin, A.; Besnier, M.; Bick, D.; Boyarkin, V.; Bozza, C.; Brugiere, T.; Brugnera, R.; Brunetti, G.; Buontempo, S.; Cazes, A.; Chaussard, L.; Chernyavsky, M.; Chiarella, V.; Chon-Sen, N.; Chukanov, A.; Cozzi, M.; D'Amato, G.; Dal Corso, F.; D'Ambrosio, N.; De Lellis, G.; Declais, Y.; De Serio, M.; Di Capua, F.; Di Ferdinando, D.; Di Giovanni, A.; Di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Ebert, J.; Egorov, O.; Enikeev, R.; Ereditato, A.; Esposito, L.S.; Favier, J.; Felici, G.; Ferber, T.; Fini, R.; Frekers, D.; Fukuda, T.; Fukushima, C.; Galkin, V.I.; Garfagnini, A.; Giacomelli, G.; Giorgini, M.; Goellnitz, C.; Goldberg, J.; Golubkov, D.; Goncharova, L.; Gornushkin, Y.; Grella, G.; Grianti, F.; Guler, M.; Gustavino, C.; Hagner, C.; Hamada, K.; Hara, T.; Hierholzer, M.; Hoshino, K.; Ieva, M.; Jakovcic, K.; Jollet, C.; Juget, F.; Kazuyama, M.; Kim, S.H.; Kimura, M.; Klicek, B.; Knuesel, J.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Kubota, H.; Lazzaro, C.; Lenkeit, J.; Ljubicic, A.; Longhin, A.; Lutter, G.; Malgin, A.; Mandrioli, G.; Marotta, A.; Marteau, J.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meisel, F.; Meregaglia, A.; Migliozzi, P.; Mikado, S.; Miyamoto, S.; Monacelli, P.; Morishima, K.; Moser, U.; Muciaccia, M.T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Naumov, D.; Nikitina, V.; Niwa, K.; Nonoyama, Y.; Ogawa, S.; Olchevski, A.; Oldorf, C.; Orlova, G.; Osedlo, V.; Paniccia, M.; Paoloni, A.; Park, B.D.; Park, I.G.; Pastore, A.; Patrizii, L.; Pennacchio, E.; Pessard, H.; Pilipenko, V.; Pistillo, C.; Policastro, G.; Polukhina, N.; Pozzato, M.; Pretzl, K.; Publichenko, P.; Pupilli, F.; Rescigno, R.; Roganova, T.; Rokujo, H.; Romano, G.; Rosa, G.; Rostovtseva, I.; Rubbia, A.; Russo, A.; Ryasny, V.; Ryazhskaya, O.; Sato, O.; Sato, Y.; Schembri, A.; Schmidt Parzefall, W.; Schroeder, H.; Scotto Lavina, L.; Sheshukov, A.; Shibuya, H.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Song, J.S.; Spinetti, M.; Stanco, L.; Starkov, N.; Stipcevic, M.; Strauss, T.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tezuka, I.; Tioukov, V.; Tolun, P.; Tran, T.; Tufanli, S.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J.L.; Wilquet, G.; Wonsak, B.; Yakushev, V.; Yoon, C.S.; Yoshioka, T.; Yoshida, J.; Zaitsev, Y.; Zemskova, S.; Zghiche, A.; Zimmermann, R.

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the atmospheric muon charge ratio in the TeV energy region. We analyzed 403069 atmospheric muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the charge ratio dependence on the primary composition. The measured charge ratio values were corrected taking into account the charge-misidentification errors. Data have also been grouped in five bins of the "vertical surface energy". A fit to a simplified model of muon production in the atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.

  7. A confirmatory factor analytic study of a self-leadership measure in South Africa

    Directory of Open Access Journals (Sweden)

    Bright Mahembe

    2013-07-01

    Full Text Available Orientation: Self-leadership is considered to be essential for effective individual functioning in occupational and academic contexts. The revised self-leadership questionnaire (RSLQ is widely utilised for measuring self-leadership, but its psychometric properties have not been established on a South African sample. By implication, important questions also exist about the theoretical structure of self-leadership in the South African context. Research purpose: The research aim of this study was to investigate the reliability and factorial validity of the revised self-leadership questionnaire on a South African sample. In doing so, the results of the research would also provide valuable insights into the latent factor structure of the self-leadership construct. Motivation for the study: On a practical level, the research sought internal validity evidence for the use of the RSLQ in the South African context. On a theoretical level, questions remain about the best conceptual representation of self-leadership as a construct. Research design, approach and method: The revised self-leadership questionnaire was administered to a non-probability sample of 375 South African young adults. The first and second-order factor structure underlying contemporary models of self-leadership using confirmatory factor analytic techniques was tested. Main findings: Results showed that the RSLQ measured self-leadership with suitable reliability and internal validity. All eight subscales had high internal consistency coefficients. Confirmatory factor analysis (CFA of the first and second-order models conclusively demonstrated good factorial validity. Practical/managerial implications: The study found that the RSLQ has good measurement properties for a South African context. Academics, practitioners and managers are urged to use the measure in its present form for applications such as leadership development and promoting self-management. Contribution/value-addition: The

  8. Mixed quantization dimensions of self-similar measures

    International Nuclear Information System (INIS)

    Dai Meifeng; Wang Xiaoli; Chen Dandan

    2012-01-01

    Highlights: ► We define the mixed quantization dimension of finitely many measures. ► Formula of mixed quantization dimensions of self-similar measures is given. ► Illustrate the behavior of mixed quantization dimension as a function of order. - Abstract: Classical multifractal analysis studies the local scaling behaviors of a single measure. However recently mixed multifractal has generated interest. The purpose of this paper is some results about the mixed quantization dimensions of self-similar measures.

  9. Development, optimisation, and application of ICP-SFMS methods for the measurement of isotope ratios

    International Nuclear Information System (INIS)

    Stuerup, S.

    2000-07-01

    The measurement of isotopic composition and isotope ratios in biological and environmental samples requires sensitive, precise, and accurate analytical techniques. The analytical techniques used are traditionally based on mass spectrometry, among these techniques is the ICP-SFMS technique, which became commercially available in the mid 1990s. This technique is characterised by high sensitivity, low background, and the ability to separate analyte signals from spectral interferences. These features are beneficial for the measurement of isotope ratios and enable the measurement of isotope ratios of elements, which it has not previously been possible to measure due to either spectral interferences or poor sensitivity. The overall purpose of the project was to investigate the potential of the single detector ICP-SFMS technique for the measurement of isotope ratios in biological and environmental samples. One part of the work has focused on the fundamental aspects of the ICP-SFMS technique with special emphasize on the features important to the measurement of isotope ratios, while another part has focused on the development, optimisation and application of specific methods for the measurement of isotope ratios of elements of nutritional interest and radionuclides. The fundamental aspects of the ICP-SFMS technique were investigated theoretically and experimentally by the measurement of isotope ratios applying different experimental conditions. It was demonstrated that isotope ratios could be measured reliably using ICP-SFMS by educated choice of acquisition parameters, scanning mode, mass discrimination correction, and by eliminating the influence of detector dead time. Applying the knowledge gained through the fundamental study, ICP-SFMS methods for the measurement of isotope ratios of calcium, zinc, molybdenum and iron in human samples and a method for the measurement of plutonium isotope ratios and ultratrace levels of plutonium and neptunium in environmental samples

  10. High precision measurements of carbon isotopic ratio of atmospheric methane using a continuous flow mass spectrometer

    Directory of Open Access Journals (Sweden)

    Shinji Morimoto

    2009-03-01

    Full Text Available A high-precision measurement system for the carbon isotope ratio of atmospheric CH4 (δ^(13CH_4 was developed using a pre-concentration device for CH4 and a gas chromatograph-combustion-isotope ratio mass spectrometer (GC-C-IRMS. The measurement system required 100 mlSTP of an atmospheric air sample, corresponding to approximately 0.18μlSTP of CH_4, to determine the δ^(13CH_4 value with a reproducibility of 0.07‰. Replicated analyses of a CH_4-in-air standard gas during the period from 2002 to 2008 indicated that the value of δ^(13CH_4 measured by this system was consistent within the measurement reproducibility. To evaluate the δ^(13CH_4 measurement system, thus developed, diurnal variations of the atmospheric CH_4 concentration and δ^(13CH_4 were observed in the northern part of the Tokyo metropolitan area. From the relationship between the CH_4 concentration and δ^(13CH_4, dominant sources of the observed CH4 fluctuations were identified.

  11. Prognostic value of the C-reactive protein to albumin ratio: a novel inflammation-based prognostic indicator in osteosarcoma

    Directory of Open Access Journals (Sweden)

    Li YJ

    2017-11-01

    Full Text Available Yong-Jiang Li,1,* Kai Yao,2,* Min-Xun Lu,2 Wen-Biao Zhang,1 Cong Xiao,2 Chong-Qi Tu2 1Department of Oncology, 2Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, People’s Republic of China *These authors contributed equally to this work Abstract: The prognostic role of the C-reactive protein to albumin ratio (CRP/Alb ratio in patients with osteosarcoma has not been investigated. A total of 216 osteosarcoma patients were enrolled in the study. Univariate and multivariate survival analyses between the groups were performed and Kaplan–Meier analysis was conducted to plot the survival curves. Receiver operating characteristic curves were generated and areas under the curve (AUCs were compared to assess the discriminatory ability of the inflammation-based indicators, including CRP/Alb ratio, Glasgow prognostic score (GPS, neutrophil–lymphocyte ratio (NLR, and platelet–lymphocyte ratio (PLR. The optimal cutoff value was 0.210 for CRP/Alb ratio with a Youden index of 0.319. Higher values of CRP/Alb ratio were significantly associated with poorer overall survival in univariate (HR =2.62, 95% CI =1.70–4.03; P<0.001 and multivariate (HR =2.21, 95% CI =1.40–3.49; P=0.001 analyses. In addition, the CRP/Alb ratio had significantly higher AUC values compared with GPS (P=0.003, NLR (P<0.001, and PLR (P<0.001. The study demonstrated that the CRP/Alb ratio is an effective inflammation-based prognostic indicator in osteosarcoma, which potentially has a discriminatory ability superior to that of other inflammatory indicators including GPS, NLR, and PLR. Keywords: osteosarcoma, CRP to albumin ratio, prognosis

  12. Energy indicators for electricity production : comparing technologies and the nature of the indicators Energy Payback Ratio (EPR), Net Energy Ratio (NER) and Cumulative Energy Demand (CED). [Oestfoldforskning AS

    Energy Technology Data Exchange (ETDEWEB)

    Raadal, Hanne Lerche [Ostfold research, Fredrikstad (Norway); Modahl, Ingunn Saur [Ostfold research, Fredrikstad (Norway); Bakken, Tor Haakon [SINTEF Energy, Trondheim (Norway)

    2012-11-01

    CEDREN (Centre for Environmental Design of Renewable Energy) is founded by The Research Council of Norway and energy companies and is one of eight centres that were part of the scheme Centre for Environment-friendly Energy Research (FME) when the scheme was launched in 2009. The main objective of CEDREN is to develop and communicate design solutions for transforming renewable energy sources to the desired energy products, and at the same time address the environmental and societal challenges at local, regional, national and global levels. CEDREN's board initiated in 2011 a pilot project on the topics 'Energy Pay-back Ratio (EPR)', 'Ecosystem services' and 'multi-criteria analysis (MCA)' in order to investigate the possible use of these concepts/indices in the management of regulated river basins and as tools to benchmark strategies for the development of energy projects/resources. The energy indicator part (documented in this report) has aimed at reviewing the applicability of different energy efficiency indicators, as such, in the strategic management and development of energy resources, and to compare and benchmark technologies for production of electricity. The main findings from this pilot study is also reported in a policy memo (in Norwegian), that is available at www.cedren.no. The work carried out in this project will be continued in the succeeding research project EcoManage, which was granted by the Research Council of Norway's RENERGI programme in December 2011. Energy indicators: Several energy indicators for extraction and delivery of an energy product (e.g. transport fuel, heat, electricity etc.) exist today. The main objective of such indicators is to give information about the energy efficiency of the needed extraction and transforming processes throughout the value chain related to the delivered energy product. In this project the indicators Energy Payback Ratio (EPR), Net Energy Ration (NER) and Cumulative

  13. Systematic review of measurement properties of self-reported instruments for evaluating self-care in adults.

    Science.gov (United States)

    Matarese, Maria; Lommi, Marzia; De Marinis, Maria Grazia

    2017-06-01

    The aims of this study were as follows: to identify instruments developed to assess self-care in healthy adults; to determine the theory on which they were based; their validity and reliability properties and to synthesize the evidence on their measurement properties. Many instruments have been developed to assess self-care in many different populations and conditions. Clinicians and researchers should select the most appropriate self-care instrument based on the knowledge of their measurement properties. Systematic review of measurement instruments according to the protocol recommended by the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. PubMed, Embase, PsycINFO, Scopus and CINAHL databases were searched from inception to December 2015. Studies testing measurement properties of self-report instruments assessing self-care in healthy adults, published in the English language and in peer review journals were selected. Two reviewers independently appraised the methodological quality of the studies with the COSMIN checklist and the quality of results using specific quality criteria. Twenty-six articles were included in the review testing the measurement properties of nine instruments. Seven instruments were based on Orem's Self-care theory. Not all the measurement properties were evaluated for the identified instruments. No self-care instrument showed strong evidence supporting the evaluated measurement properties. Despite the development of several instruments to assess self-care in the adult population, no instrument can be fully recommended to clinical nurses and researchers. Further studies of high methodological quality are needed to confirm the measurement properties of these instruments. © 2016 John Wiley & Sons Ltd.

  14. Using Implicit and Explicit Measures to Predict Nonsuicidal Self-Injury Among Adolescent Inpatients.

    Science.gov (United States)

    Cha, Christine B; Augenstein, Tara M; Frost, Katherine H; Gallagher, Katie; D'Angelo, Eugene J; Nock, Matthew K

    2016-01-01

    To examine the use of implicit and explicit measures to predict adolescent nonsuicidal self-injury (NSSI) before, during, and after inpatient hospitalization. Participants were 123 adolescent psychiatric inpatients who completed measures at hospital admission and discharge. The implicit measure (Self-Injury Implicit Association Test [SI-IAT]) and one of the explicit measures pertained to the NSSI method of cutting. Patients were interviewed at multiple time points at which they reported whether they had engaged in NSSI before their hospital stay, during their hospital stay, and within 3 months after discharge. At baseline, SI-IAT scores differentiated past-year self-injurers and noninjurers (t121 = 4.02, p < .001, d = 0.73). These SI-IAT effects were stronger among patients who engaged in cutting (versus noncutting NSSI methods). Controlling for NSSI history and prospective risk factors, SI-IAT scores predicted patients' subsequent cutting behavior during their hospital stay (odds ratio (OR) = 8.19, CI = 1.56-42.98, p < .05). Patients' explicit self-report uniquely predicted hospital-based and postdischarge cutting, even after controlling for SI-IAT scores (ORs = 1.82-2.34, CIs = 1.25-3.87, p values <.01). Exploratory analyses revealed that in specific cases in which patients explicitly reported low likelihood of NSSI, SI-IAT scores still predicted hospital-based cutting. The SI-IAT is an implicit measure that is outcome-specific, a short-term predictor above and beyond NSSI history, and potentially helpful in cases in which patients at risk for NSSI explicitly report that they would not do so in the future. Ultimately, both implicit and explicit measures can help to predict future incidents of cutting among adolescent inpatients. Copyright © 2016 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  15. Measurement of Poisson's ratio of nonmetallic materials by laser holographic interferometry

    Science.gov (United States)

    Zhu, Jian T.

    1991-12-01

    By means of the off-axis collimated plane wave coherent light arrangement and a loading device by pure bending, Poisson's ratio values of CFRP (carbon fiber-reinforced plactics plates, lay-up 0 degree(s), 90 degree(s)), GFRP (glass fiber-reinforced plactics plates, radial direction) and PMMA (polymethyl methacrylate, x, y direction) have been measured. In virtue of this study, the ministry standard for the Ministry of Aeronautical Industry (Testing method for the measurement of Poisson's ratio of non-metallic by laser holographic interferometry) has been published. The measurement process is fast and simple. The measuring results are reliable and accurate.

  16. Self-healing of polymer modified concrete

    Directory of Open Access Journals (Sweden)

    Abd_Elmoaty M. Abd_Elmoaty

    2011-06-01

    Full Text Available Self healing phenomenon of concrete has been observed in traditional, fibrous, self compacting concrete. This phenomenon occurred mainly due to the presence of unhydrated cement particles in the presence of water. Mechanism of polymer in concrete depends on creating a layer and net of polymer around cement particles which enhances the properties of polymer modified concrete. This mechanism may affect the self healing of this type of concrete. This work aims to study the presence of the self healing phenomenon in polymer modified concrete and the related parameters. An experimental investigation on self healing of polymer modified concrete was undertaken. In this research work, effect of polymer type, polymer dose, cement content, cement type, w/cm ratio and age of damage were studied. The healing process extended up to 60 days. Ultrasonic pulse velocity measurements were used to evaluate the healing process. Results indicated that, the self healing phenomenon existed in polymer modified concrete as in traditional concrete. The increase of polymer dose increases the healing degree at the same healing time. This increase depends on polymer type. Also, the decrease of w/cm ratio reduces the self healing degree while the use of Type V Portland cement improves the self healing process compared with Type I Portland cement. Cement content has an insignificant effect on healing process for both concrete with and without polymer. In addition, the increase of damage age decreases the efficiency of self healing process.

  17. Coupled orbit-attitude motion of high area-to-mass ratio (HAMR) objects including efficient self-shadowing

    Science.gov (United States)

    Früh, Carolin; Jah, Moriba K.

    2014-02-01

    This paper shows the effect of self-shadowing on the coupled attitude-orbit dynamics of objects with high area-to-mass ratios (HAMR) in simulating standard multi layer insulation materials (MLI) as tilted single rigid sheets. Efficient and computationally fast self-shadowing methods have been developed. This includes an approximate self-shadowing method and a rapid exact self-shadowing method. Accuracy considerations are made and the effect of a chosen tessellation is shown. The coupled orbit-attitude perturbations of solar radiation pressure and Earth gravity field are taken into account. The results are compared to the attitude-orbit dynamics, when neglecting self-shadowing effects. An averaged physical shadow-map model is developed and compared to the full self-shadowing simulation. The combined effect of solar radiation pressure and self-shadowing leads to a rapid spin-up of the objects, even though they have uniform reflection properties. As a result, the observed brightness of these objects is subject to rapid changes.

  18. Measurement of a Cosmographic Distance Ratio with Galaxy and Cosmic Microwave Background Lensing.

    Science.gov (United States)

    Miyatake, Hironao; Madhavacheril, Mathew S; Sehgal, Neelima; Slosar, Anže; Spergel, David N; Sherwin, Blake; van Engelen, Alexander

    2017-04-21

    We measure the gravitational lensing shear signal around dark matter halos hosting constant mass galaxies using light sources at z∼1 (background galaxies) and at the surface of last scattering at z∼1100 (the cosmic microwave background). The galaxy shear measurement uses data from the CFHTLenS survey, and the microwave background shear measurement uses data from the Planck satellite. The ratio of shears from these cross-correlations provides a purely geometric distance measurement across the longest possible cosmological lever arm. This is because the matter distribution around the halos, including uncertainties in galaxy bias and systematic errors such as miscentering, cancels in the ratio for halos in thin redshift slices. We measure this distance ratio in three different redshift slices of the constant mass (CMASS) sample and combine them to obtain a 17% measurement of the distance ratio, r=0.390_{-0.062}^{+0.070}, at an effective redshift of z=0.53. This is consistent with the predicted ratio from the Planck best-fit cold dark matter model with a cosmological constant cosmology of r=0.419.

  19. Clarifying the use of aggregated exposures in multilevel models: self-included vs. self-excluded measures.

    Directory of Open Access Journals (Sweden)

    Etsuji Suzuki

    Full Text Available Multilevel analyses are ideally suited to assess the effects of ecological (higher level and individual (lower level exposure variables simultaneously. In applying such analyses to measures of ecologies in epidemiological studies, individual variables are usually aggregated into the higher level unit. Typically, the aggregated measure includes responses of every individual belonging to that group (i.e. it constitutes a self-included measure. More recently, researchers have developed an aggregate measure which excludes the response of the individual to whom the aggregate measure is linked (i.e. a self-excluded measure. In this study, we clarify the substantive and technical properties of these two measures when they are used as exposures in multilevel models.Although the differences between the two aggregated measures are mathematically subtle, distinguishing between them is important in terms of the specific scientific questions to be addressed. We then show how these measures can be used in two distinct types of multilevel models-self-included model and self-excluded model-and interpret the parameters in each model by imposing hypothetical interventions. The concept is tested on empirical data of workplace social capital and employees' systolic blood pressure.Researchers assume group-level interventions when using a self-included model, and individual-level interventions when using a self-excluded model. Analytical re-parameterizations of these two models highlight their differences in parameter interpretation. Cluster-mean centered self-included models enable researchers to decompose the collective effect into its within- and between-group components. The benefit of cluster-mean centering procedure is further discussed in terms of hypothetical interventions.When investigating the potential roles of aggregated variables, researchers should carefully explore which type of model-self-included or self-excluded-is suitable for a given situation

  20. 78 FR 79310 - Partial Section Eight Management Assessment Program (SEMAP) Indicator Waiver; Family Self...

    Science.gov (United States)

    2013-12-30

    ... Section Eight Management Assessment Program (SEMAP) Indicator Waiver; Family Self-Sufficiency (FSS... rating criteria at 24 CFR 985.3(o) (``Family self-sufficiency (FSS) enrollment and escrow accounts... Family Self-Sufficiency (FSS) Program Demonstration is a random assignment study conducted under contract...

  1. The Effect of Trait Self-Awareness, Self-Reflection, and Perceptions of Choice Meaningfulness on Indicators of Social Identity within a Decision-Making Context.

    Science.gov (United States)

    Dishon, Noam; Oldmeadow, Julian A; Critchley, Christine; Kaufman, Jordy

    2017-01-01

    Theorists operating from within a narrative identity framework have suggested that self-reflective reasoning plays a central role in the development of the self. Typically, however, narrative identity researchers have investigated this relationship using correlational rather than experimental methods. In the present study, leveraging on a classic research paradigm from within the social identity literature we developed an experiment to test the extent to which self-reflection might have a causal impact on the self-concept within a decision-making context. In a minimal group paradigm participants were prompted to reflect on their painting choices either before or after allocating points to in-group∖ out-group members. As anticipated, self-reflection augmented social identification, but only when participants felt their choices were personally meaningful. Participants who reasoned about their choices and felt they were subjectively meaningful showed stronger similarity and liking for in-group members compared to those who did not reflect on their choices or found them to be subjectively meaningless. Hence, reflecting on and finding meaning in one's choices may be an important step in linking behavior with in-group identification and thus the self-concept in turn. The absence of any effects on in-group favoritism (a third indicator of social identification measured) as well as implications of the study's findings for self-perception, cognitive dissonance and social identity processes are also discussed.

  2. Effect of heterophoria measurement technique on the clinical accommodative convergence to accommodation ratio.

    Science.gov (United States)

    Escalante, Jaime Bernal; Rosenfield, Mark

    2006-05-01

    Measurement of the stimulus accommodative convergence to accommodation (AC/A) ratio is a standard procedure in clinical optometric practice. Typically, heterophoria is assessed at several accommodative stimulus levels, and the gradient of the vergence to accommodation function computed. A number of procedures are available for the subjective measurement of heterophoria, but it is unclear whether the use of different vergence measurement techniques will alter the obtained AC/A value. Accordingly, the current study compared AC/A ratios measured using 3 clinical subjective heterophoria tests, namely the von Graefe (VG), Maddox Rod (MR), and Modified Thorington (MT) procedures. The AC/A ratio was measured in 60 visually normal subjects between 20 and 25 years of age using each of the 3 procedures listed above. The accommodative stimulus was varied by the introduction of +/-1.00 diopter (D) spherical lenses over the distance refractive correction while subjects viewed a target at a viewing distance of 40 cm. To examine the repeatability of each procedure, the AC/A ratio was measured on 2 separate occasions for each measurement technique, with the 2 sessions being separated by at least 24 hours. Mean values of stimulus AC/A ratio measured using the VG, MR, and MT procedures were 3.47, 2.99, and 2.46Delta/D, respectively. These differences were significant (p=0.0001). In addition, the coefficient of repeatability for the 3 techniques was 2.22, 1.99, and 1.20 Delta/D, respectively. Ratios obtained using the Modified Thorington technique with +/-1.00 D lenses showed the best repeatability, whereas the poorest repeatability was found with the von Graefe technique when only +1.00 D lenses were used to vary the accommodative stimulus. Accordingly, we recommend that that Modified Thorington procedure with +/-1.00 D lenses be used to quantify heterophoria during clinical measurement of the stimulus AC/A ratio.

  3. Self-Report Measures of Family Competence.

    Science.gov (United States)

    Green, Robert G.

    1987-01-01

    Describes and compares two self-report measures of family competence: the Family Awareness Scales (FAS) (Green and Kolevzon, late 1970s) and the Self-Report Family Inventory (SFI) (Beavers, 1983). Discusses reliability and validity. Their focus on the "insider" (family member) is different from the traditional examination of family…

  4. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

    Science.gov (United States)

    Kim, Pil-Jong; Kim, Hong-Gee; Cho, Byeong-Hoon

    2015-05-01

    The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  5. Measurement of the charge ratio of atmospheric muons with the CMS detector

    Energy Technology Data Exchange (ETDEWEB)

    Khachatryan, Vardan [Yerevan Physics Inst. (Armenia); et al.

    2010-08-01

    We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 \\pm 0.0032(stat.) \\pm 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments.

  6. Soil microbial C:N ratio is a robust indicator of soil productivity for paddy fields

    Science.gov (United States)

    Li, Yong; Wu, Jinshui; Shen, Jianlin; Liu, Shoulong; Wang, Cong; Chen, Dan; Huang, Tieping; Zhang, Jiabao

    2016-10-01

    Maintaining good soil productivity in rice paddies is important for global food security. Numerous methods have been developed to evaluate paddy soil productivity (PSP), most based on soil physiochemical properties and relatively few on biological indices. Here, we used a long-term dataset from experiments on paddy fields at eight county sites and a short-term dataset from a single field experiment in southern China, and aimed at quantifying relationships between PSP and the ratios of carbon (C) to nutrients (N and P) in soil microbial biomass (SMB). In the long-term dataset, SMB variables generally showed stronger correlations with the relative PSP (rPSP) compared to soil chemical properties. Both correlation and variation partitioning analyses suggested that SMB N, P and C:N ratio were good predictors of rPSP. In the short-term dataset, we found a significant, negative correlation of annual rice yield with SMB C:N (r = -0.99), confirming SMB C:N as a robust indicator for PSP. In treatments of the short-term experiment, soil amendment with biochar lowered SMB C:N and improved PSP, while incorporation of rice straw increased SMB C:N and reduced PSP. We conclude that SMB C:N ratio does not only indicate PSP but also helps to identify management practices that improve PSP.

  7. White-tailed deer age ratios as herd management and predator impact measures in Pennsylvania

    Science.gov (United States)

    Rosenberry, Christopher S.; Norton, Andrew S.; Diefenbach, Duane R.; Fleegle, Jeannine T.; Wallingford, Bret D.

    2011-01-01

    A review of the Pennsylvania Game Commission's (PGC) deer management program and public concern about predator impacts on deer (Odocoileus virginianus) populations compelled the PGC to investigate the role of age ratios in developing management recommendations. Age ratios, such as proportion of juveniles in the antlerless harvest, may provide an index to population productivity and predator impacts. We estimated proportion of juveniles in the antlerless harvest from hunter-killed deer, population trends using the Pennsylvania (USA) sex–age–kill model, and reproduction from road-killed females. Using these estimates and a simulation model, we concluded that no single age-ratio value would serve as a reliable measure of population status. Wildlife Management Unit-specific trends in proportion of juveniles in the antlerless harvest and population trends provided the most relevant management information. We also provide an example decision chart to guide management actions in response to declining age ratios in the harvest. Although predator management activities and juvenile survival studies are often desired by the public, our decision-chart example indicated a number of deer management options exist before investing resources in predator management activities and juvenile survival studies.

  8. Supplementary Material for: Linking local retention, self-recruitment, and persistence in marine metapopulations

    KAUST Repository

    Lett, Christophe

    2016-01-01

    Three indices of larval retention have been used in the literature to assess the tendency for self-maintenance of local marine populations: local retention (LR), self-recruitment (SR), and relative local retention (RLR). Only one of these, LR, defined as the ratio of locally produced settlement to local egg production, has a clear relationship to self-persistence of individual sites. However, SR, the ratio of locally produced settlement to settlement of all origins at a site, is generally easier to measure experimentally. We use theoretical, simulation, and empirical approaches to bridge the gap between these different indices, and demonstrate that there is a proportional relationship between SR and LR for metapopulations close to a stable state and with lifetime egg production (LEP) approximately uniform over space. Similarly, for systems where larval mortality rates are a relatively uniform function of release site, RLR (defined as the ratio of locally produced settlement to all settlement of local origin) and LR will also be proportional. Therefore, SR and RLR provide information on relative rates of LR for systems satisfying these conditions. Furthermore, the ratio between LR and SR can be used to evaluate global persistence of metapopulations, and therefore provides valuable information not necessarily available if only LR is considered.

  9. Waist-to-height ratio, waist circumference and BMI as indicators of percentage fat mass and cardiometabolic risk factors in children aged 3-7 years

    NARCIS (Netherlands)

    Sijtsma, Anna; Bocca, Gianni; L'abée, Carianne; Liem, Eryn T; Sauer, Pieter J J; Corpeleijn, Eva

    Objective: To assess whether waist-to-height-ratio (WHtR) is a better estimate of body fat percentage (BF %) and a better indicator of cardiometabolic risk factors than BMI or waist circumference (WC) in young children. Methods: WHtR, WC and BMI were measured by trained staff according to

  10. [Social self-positioning as indicator of socioeconomic status].

    Science.gov (United States)

    Fernández, E; Alonso, R M; Quer, A; Borrell, C; Benach, J; Alonso, J; Gómez, G

    2000-01-01

    Self-perceived class results from directly questioning subjects about his or her social class. The aim of this investigation was to analyse self-perceived class in relation to other indicator variables of socioeconomic level. Data from the 1994 Catalan Health Interview Survey, a cross-sectional survey of a representative sample of the non-institutionalised population of Catalonia was used. We conducted a discriminant analysis to compute the degree of right classification when different socioeconomic variables potentially related to self-perceived class were considered. All subjects who directly answered the questionnaire were included (N = 12,245). With the aim of obtaining the discriminant functions in a group of subjects and to validate it in another one, the subjects were divided into two random samples, containing approximately 75% and 25% of subjects (analysis sample, n = 9,248; and validation sample, n = 2,997). The final function for men and women included level of education, social class (based in occupation) and equivalent income. This function correctly classified 40.9% of the subjects in the analysis sample and 39.2% in the validation sample. Two other functions were selected for men and women separately. In men, the function included level of education, professional category, and family income (39.2% of classification in analysis sample and 37.2% in validation sample). In women, the function (level of education, working status, and equivalent income) correctly classified 40.3% of women in analysis sample whereas the percentage was 38.9% in validation sample. The percentages of right classification were higher for the highest and lowest classes. These results show the utility of a simple variable to self-position within the social scale. Self-perceived class is related to education, income, and working determinants.

  11. Self-esteem revisited: performance on the implicit relational assessment procedure as a measure of self- versus ideal self-related cognitions in dysphoria.

    Science.gov (United States)

    Remue, Jonathan; De Houwer, Jan; Barnes-Holmes, Dermot; Vanderhasselt, Marie-Anne; De Raedt, Rudi

    2013-01-01

    Although depression is characterised by low self-esteem as measured by questionnaires, research using implicit measures of self-esteem has failed to reveal the expected differences between depressed and non-depressed individuals. In this study, we used an implicit measure which enables the differentiation of ideal self- and actual self-esteem, through the introduction of propositions: "I am" versus "I want to be". We measured implicit relational associations about actual and ideal self in low (N=27) versus high dysphoric (N=29) undergraduates. Our data revealed that dysphoric individuals have a higher ideal self-esteem, and lower actual self-esteem in comparison to healthy participants. The results underscore the need to go beyond simple associations and suggest that the use of individual-specific propositions could enhance our understanding of the implicit measurement of self-esteem. Furthermore, these results underscore the importance of actual versus ideal self-discrepancy theories, which might guide the content of therapeutic interventions.

  12. Variability of Measurement of Patellofemoral Indices with Knee Flexion and Quadriceps Contraction: An MRI-Based Anatomical Study

    Science.gov (United States)

    Laugharne, Edward; Bali, Navi; Purushothamdas, Sanjay; Almallah, Faris; Kundra, Rik

    2016-01-01

    Purpose The purpose of this study was to investigate the impact of varying knee flexion and quadriceps activity on patellofemoral indices measured on magnetic resonance imaging (MRI). Materials and Methods MRI of the knee was performed in 20 patients for indications other than patellar or patellofemoral pathology. Axial and sagittal sequences were performed in full extension of the knee with the quadriceps relaxed, full extension of the knee with the quadriceps contracted, 30° flexion of the knee with the quadriceps relaxed, and 30° flexion with the quadriceps contracted. Bisect offset, patella tilt angle, Insall-Salvati ratio and Caton-Deschamps index were measured. Results With the knee flexed to 30° and quadriceps relaxed, the mean values of patellar tilt angle, bisect offset, Insall-Salvati ratio and Caton-Deschamps index were all within normal limits. With the knee extended and quadriceps contracted, the mean patellar tilt angle (normal value, patellofemoral indices. MRI taken with the knee in 30° of flexion allows more reliable assessment of the patellofemoral joint and minimises the confounding effect of quadriceps contraction. PMID:27894177

  13. Measuring School Psychology Trainee Self-Efficacy

    Science.gov (United States)

    Lockwood, Adam B.; Mcclure, John; Sealander, Karen; Baker, Courtney N.

    2017-01-01

    There is an ever-increasing need for school psychology training programs to demonstrate their ability to produce competent practitioners. One method of addressing this need is through the assessment of self-efficacy. However, little research on self-efficacy in school psychology exists likely due to the lack of a psychometrically sound measure of…

  14. [Therapeutic goals and indications: psychotherapy patient's self-reports during diagnostic assessment].

    Science.gov (United States)

    Faller, H

    2000-07-01

    Although individual therapeutic goals are considered to be important factors motivating patients to engage in therapeutic work, they have gained little attention in empirical research. In the present study, patients were given a questionnaire containing 24 therapeutic goals which could be rated according to their subjective relevance on a 5-point scale. N = 152 patients (mean age 34.5 years, 59.2% female) who presented at a university psychotherapy outpatient department to attend a diagnostic interview participated in the study. "To solve my problems" and "to get relief from my complaints" were the goals that were rated as most important. Goals pertaining to mental health such as more contentness and calmness, self-assertion and insight scored high, too. Three rational scales were constructed: 1. insight, 2. sociability, and 3. self-assertion. These scales were correlated with both patients' causal attributions and therapy expectations in plausible ways. However, the general strength of intercorrelations point of the conception patients goals were not very succinct at the time of the intake interview. Indication groups regarding specific therapeutic measures did not differ with respect to therapy goals. Only the general decision whether to recommend a psychotherapeutic intervention or not seemed to be influenced by patients' therapeutic aims.

  15. Comparative study on DuPont analysis and DEA models for measuring stock performance using financial ratio

    Science.gov (United States)

    Arsad, Roslah; Shaari, Siti Nabilah Mohd; Isa, Zaidi

    2017-11-01

    Determining stock performance using financial ratio is challenging for many investors and researchers. Financial ratio can indicate the strengths and weaknesses of a company's stock performance. There are five categories of financial ratios namely liquidity, efficiency, leverage, profitability and market ratios. It is important to interpret the ratio correctly for proper financial decision making. The purpose of this study is to compare the performance of listed companies in Bursa Malaysia using Data Envelopment Analysis (DEA) and DuPont analysis Models. The study is conducted in 2015 involving 116 consumer products companies listed in Bursa Malaysia. The estimation method of Data Envelopment Analysis computes the efficiency scores and ranks the companies accordingly. The Alirezaee and Afsharian's method of analysis based Charnes, Cooper and Rhodes (CCR) where Constant Return to Scale (CRS) is employed. The DuPont analysis is a traditional tool for measuring the operating performance of companies. In this study, DuPont analysis is used to evaluate three different aspects such as profitability, efficiency of assets utilization and financial leverage. Return on Equity (ROE) is also calculated in DuPont analysis. This study finds that both analysis models provide different rankings of the selected samples. Hypothesis testing based on Pearson's correlation, indicates that there is no correlation between rankings produced by DEA and DuPont analysis. The DEA ranking model proposed by Alirezaee and Asharian is unstable. The method cannot provide complete ranking because the values of Balance Index is equal and zero.

  16. Suitability of the AUC Ratio as an Indicator of the Pharmacokinetic Advantage in HIPEC.

    Science.gov (United States)

    Mas-Fuster, Maria Isabel; Ramon-Lopez, Amelia; Lacueva, Javier; Más-Serrano, Patricio; Nalda-Molina, Ricardo

    2018-02-01

    The purpose of this study was to evaluate the area under the concentration-time curve (AUC) ratio as an optimal indicator of the pharmacokinetic advantage during hyperthermic intraperitoneal perioperative chemotherapy. The impact on the AUC ratio on the variables related to the calculation of systemic drug exposure, instillation time, and peripheral drug distribution was evaluated through simulations as well as through a retrospective analysis of studies published in the literature. Both model simulations and the retrospective analysis showed that the 3 variables evaluated had an impact on the AUC ratio value if the complete systemic exposure was not fully considered. However, when that complete systemic exposure was considered, none of these variables affected the AUC ratio value. AUC ratio is not a characteristic parameter of a drug if the calculated systemic drug exposure is not complete. Thus, AUC ratio is not valid for comparing the pharmacokinetic advantage of 2 drugs, and it should not be employed to prove whether a drug can be used in hyperthermic intraperitoneal perioperative chemotherapy safely with regard to toxicity. As an alternative, the study of the absorption rate constant and the bioavailability are proposed as the true and independent parameters that reflect the amount of drug absorbed. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. Measuring and decomposing inequity in self-reported morbidity and self-assessed health in Thailand

    Directory of Open Access Journals (Sweden)

    Sidorenko Alexandra

    2007-12-01

    Full Text Available Abstract Background In recent years, interest in the study of inequalities in health has not stopped at quantifying their magnitude; explaining the sources of inequalities has also become of great importance. This paper measures socioeconomic inequalities in self-reported morbidity and self-assessed health in Thailand, and the contributions of different population subgroups to those inequalities. Methods The Health and Welfare Survey 2003 conducted by the Thai National Statistical Office with 37,202 adult respondents is used for the analysis. The health outcomes of interest derive from three self-reported morbidity and two self-assessed health questions. Socioeconomic status is measured by adult-equivalent monthly income per household member. The concentration index (CI of ill health is used as a measure of socioeconomic health inequalities, and is subsequently decomposed into contributing factors. Results The CIs reveal inequality gradients disadvantageous to the poor for both self-reported morbidity and self-assessed health in Thailand. The magnitudes of these inequalities were higher for the self-assessed health outcomes than for the self-reported morbidity outcomes. Age and sex played significant roles in accounting for the inequality in reported chronic illness (33.7 percent of the total inequality observed, hospital admission (27.8 percent, and self-assessed deterioration of health compared to a year ago (31.9 percent. The effect of being female and aged 60 years or older was by far the strongest demographic determinant of inequality across all five types of health outcome. Having a low socioeconomic status as measured by income quintile, education and work status were the main contributors disadvantaging the poor in self-rated health compared to a year ago (47.1 percent and self-assessed health compared to peers (47.4 percent. Residence in the rural Northeast and rural North were the main regional contributors to inequality in self

  18. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

    Directory of Open Access Journals (Sweden)

    Pil-Jong Kim

    2015-05-01

    Full Text Available Objectives The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL. Materials and Methods The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  19. Indicators of opinion leadership in customer networks : self-reports and degree centrality

    NARCIS (Netherlands)

    Risselada, Hans; Verhoef, Pieter; Bijmolt, Tammo

    In this paper, we assess two alternative indicators of opinion leadership, self-reported opinion leadership and degree centrality, on the same dataset. We also investigate the interaction effect of these two indicators and the social network environment on opinion leadership. We use social network

  20. Measurement of the charge ratio of atmospheric muons with the CMS detector

    CERN Document Server

    AUTHOR|(CDS)2070976

    2010-01-01

    5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 $\\pm$ 0.0032 (stat.) $\\pm$ 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic-ray shower models and compatible with previous measurements by deep-underground experiments.

  1. Isokinetic Hamstrings: Quadriceps Ratios in Intercollegiate Athletes.

    Science.gov (United States)

    Rosene, John M.; Fogarty, Tracey D.; Mahaffey, Brian L.

    2001-01-01

    Compared the differences in the concentric hamstrings to quadriceps (H:Q) ratio among athletes in different sports at three velocities. Measurement of H:Q ratio of both knees among male and female college athletes indicated that the H:Q ratio increased as velocity increased. No differences existed for the H:Q ratio for sport or side of body. (SM)

  2. Measuring the Effects of Self-Awareness: Construction of the Self-Awareness Outcomes Questionnaire

    Directory of Open Access Journals (Sweden)

    Anna Sutton

    2016-11-01

    Full Text Available Dispositional self-awareness is conceptualized in several different ways, including insight, reflection, rumination and mindfulness, with the latter in particular attracting extensive attention in recent research. While self-awareness is generally associated with positive psychological well-being, these different conceptualizations are also each associated with a range of unique outcomes. This two part, mixed methods study aimed to advance understanding of dispositional self-awareness by developing a questionnaire to measure its outcomes. In Study 1, expert focus groups categorized and extended an initial pool of potential items from previous research. In Study 2, these items were reduced to a 38 item self-report questionnaire with four factors representing three beneficial outcomes (reflective self-development, acceptance and proactivity and one negative outcome (costs. Regression of these outcomes against self-awareness measures revealed that self-reflection and insight predicted beneficial outcomes, rumination predicted reduced benefits and increased costs, and mindfulness predicted both increased proactivity and costs. These studies help to refine the self-awareness concept by identifying the unique outcomes associated with the concepts of self-reflection, insight, reflection, rumination and mindfulness. It can be used in future studies to evaluate and develop awareness-raising techniques to maximize self-awareness benefits while minimizing related costs.

  3. Principles of fuel ion ratio measurements in fusion plasmas by collective Thomson scattering

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Nielsen, Stefan Kragh; Bindslev, Henrik

    2011-01-01

    ratio. Measurements of the fuel ion ratio will be important for plasma control and machine protection in future experiments with burning fusion plasmas. Here we examine the theoretical basis for fuel ion ratio measurements by CTS. We show that the sensitivity to plasma composition is enhanced......For certain scattering geometries collective Thomson scattering (CTS) measurements are sensitive to the composition of magnetically confined fusion plasmas. CTS therefore holds the potential to become a new diagnostic for measurements of the fuel ion ratio—i.e. the tritium to deuterium density...... by the signatures of ion cyclotron motion and ion Bernstein waves which appear for scattering geometries with resolved wave vectors near perpendicular to the magnetic field. We investigate the origin and properties of these features in CTS spectra and give estimates of their relative importance for fuel ion ratio...

  4. Emotional eating and physical activity self-efficacy as pathways in the association between depressive symptoms and adiposity indicators.

    Science.gov (United States)

    Konttinen, Hanna; Silventoinen, Karri; Sarlio-Lähteenkorva, Sirpa; Männistö, Satu; Haukkala, Ari

    2010-11-01

    There is increasing evidence that depressive symptoms and obesity are positively related, but the mechanisms that explain the association between them are unclear. We examined direct and indirect associations between depressive symptoms, emotional eating, physical activity (PA) self-efficacy (ie, an individual's confidence in his or her ability to overcome barriers to maintain PA behaviors), and adiposity indicators. Structural equation modeling was used to test the hypothesized mediation model in Finnish men (n = 2312) and women (n = 2674) aged 25-74 y from the National Cardiovascular Risk Factor Survey conducted in 2007. The Center for Epidemiologic Studies-Depression Scale, the Three-Factor Eating Questionnaire-R18, and a PA barriers self-efficacy scale were used. Body mass index (BMI), waist circumference (WC), and percentage body fat of participants were measured in a health examination. Depressive symptoms and emotional eating had positive correlations and PA self-efficacy had negative correlations with BMI, WC, and percentage body fat. Elevated depressive symptoms were related to higher emotional eating (β = 0.38 for men and 0.31 for women) and lower PA self-efficacy (β = -0.41 for men and -0.31 for women), whereas emotional eating and PA self-efficacy were inversely correlated (r = -0.12 and -0.18, respectively). The positive bivariate associations between depressive symptoms and adiposity indicators became nonsignificant in models that included emotional eating and PA self-efficacy, and both of these factors significantly mediated the effects of depressive symptoms on adiposity indicators. Psychological factors related to both eating and PA may be relevant in explaining the positive relation between depressive symptoms and adiposity. Interventions that target obesity should take into account the effects of these factors on weight regulation.

  5. Academic Self-Concept: Modeling and Measuring for Science

    Science.gov (United States)

    Hardy, Graham

    2014-08-01

    In this study, the author developed a model to describe academic self-concept (ASC) in science and validated an instrument for its measurement. Unlike previous models of science ASC, which envisage science as a homogenous single global construct, this model took a multidimensional view by conceiving science self-concept as possessing distinctive facets including conceptual and procedural elements. In the first part of the study, data were collected from 1,483 students attending eight secondary schools in England, through the use of a newly devised Secondary Self-Concept Science Instrument, and structural equation modeling was employed to test and validate a model. In the second part of the study, the data were analysed within the new self-concept framework to examine learners' ASC profiles across the domains of science, with particular attention paid to age- and gender-related differences. The study found that the proposed science self-concept model exhibited robust measures of fit and construct validity, which were shown to be invariant across gender and age subgroups. The self-concept profiles were heterogeneous in nature with the component relating to self-concept in physics, being surprisingly positive in comparison to other aspects of science. This outcome is in stark contrast to data reported elsewhere and raises important issues about the nature of young learners' self-conceptions about science. The paper concludes with an analysis of the potential utility of the self-concept measurement instrument as a pedagogical device for science educators and learners of science.

  6. Alternative indicators for measuring hospital productivity.

    Science.gov (United States)

    Serway, G D; Strum, D W; Haug, W F

    1987-08-01

    This article explores the premise that the appropriateness and usefulness of typical hospital productivity measures have been affected by three changes in delivery: Organizational restructuring and other definition and data source changes that make full-time equivalent employee (FTE) measurements ambiguous. Transition to prospective payment (diagnosis-related groups). Increase in capitation (prepaid, at risk) programs. The effects of these changes on productivity management indicate the need for alternative productivity indicators. Several productivity measures that complement these changes in internal operations and the external hospital business environment are presented. These are based on an analysis of four hospitals within a multihospital system, and an illustration and interpretation of an array of measures, based on ten months of actual data, is provided. In conclusion, the recommendation is made for hospital management to collect an expanded set of productivity measures and review them in light of changing expense and revenue management schemes inherent in new payment modes.

  7. Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

    Science.gov (United States)

    Conti, C. C.; Anjos, M. J.; Salgado, C. M.

    2014-09-01

    X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at www.macx.net.br.

  8. Tolerance analysis in manufacturing using process capability ratio with measurement uncertainty

    DEFF Research Database (Denmark)

    Mahshid, Rasoul; Mansourvar, Zahra; Hansen, Hans Nørgaard

    2017-01-01

    . In this paper, a new statistical analysis was applied to manufactured products to assess achieved tolerances when the process is known while using capability ratio and expanded uncertainty. The analysis has benefits for process planning, determining actual precision limits, process optimization, troubleshoot......Tolerance analysis provides valuable information regarding performance of manufacturing process. It allows determining the maximum possible variation of a quality feature in production. Previous researches have focused on application of tolerance analysis to the design of mechanical assemblies...... malfunctioning existing part. The capability measure is based on a number of measurements performed on part’s quality variable. Since the ratio relies on measurements, elimination of any possible error has notable negative impact on results. Therefore, measurement uncertainty was used in combination with process...

  9. Measurements of K shell absorption jump factors and jump ratios using EDXRF technique

    Science.gov (United States)

    Kacal, Mustafa Recep; Han, İbrahim; Akman, Ferdi

    2015-04-01

    In the present work, the K-shell absorption jump factors and jump ratios for 30 elements between Ti ( Z = 22) and Er ( Z = 68) were measured by energy dispersive X-ray fluorescence (EDXRF) technique. The jump factors and jump ratios for these elements were determined by measuring the K shell fluorescence parameters such as the Kα X-ray production cross-sections, K shell fluorescence yields, Kβ-to- Kα X-rays intensity ratios, total atomic absorption cross sections and mass attenuation coefficients. The measurements were performed using an Am-241 radioactive point source and a Si (Li) detector in direct excitation and transmission experimental geometry. The results for jump factors and jump ratios were compared with theoretically calculated and the ones available in the literature.

  10. Validation of a measurement tool for self-assessment of teamwork in intensive care.

    Science.gov (United States)

    Weller, J; Shulruf, B; Torrie, J; Frengley, R; Boyd, M; Paul, A; Yee, B; Dzendrowskyj, P

    2013-09-01

    Teamwork is an important contributor to patient safety and a validated teamwork measurement tool could help healthcare teams identify areas for improvement and measure progress. We explored the psychometric properties of a teamwork measurement tool when used for self-assessment. We hypothesized that the tool had a valid factor structure and that scores from participants and external assessors would correlate. Forty intensive care teams (one doctor, three nurses) participated in four simulated emergencies, and each independently rated their team's performance at the end of each case using the teamwork measurement tool, without prior training in the use of the tool. We used exploratory factor analysis (EFA) and confirmatory factor analysis (CFA), and compared factor structure between participants and external assessors (using previously reported data). Scores from participants and external assessors were compared using Pearson's correlation coefficient. EFA demonstrated items loaded onto three distinct factors which were supported by the CFA. We found significant correlations between external and participant scores for overall teamwork scores and the three factors. Participants agreed with external assessors on the ranking of overall team performance but scored themselves significantly higher than external assessors. The teamwork measurement tool has a valid structure when used for self-assessment. Participant and external assessor scores correlated significantly, suggesting that participants could discriminate between different levels of performance, although leniency in self-assessed scores indicated the need for calibration. This tool could help structure reflection on teamwork and potentially facilitate self-directed, workplace-based improvement in teamwork.

  11. Pattern description and reliability parameters of six force-time related indices measured with plantar pressure measurements.

    Science.gov (United States)

    Deschamps, Kevin; Roosen, Philip; Bruyninckx, Herman; Desloovere, Kaat; Deleu, Paul-Andre; Matricali, Giovanni A; Peeraer, Louis; Staes, Filip

    2013-09-01

    Functional interpretation of plantar pressure measurements is commonly done through the use of ratios and indices which are preceded by the strategic combination of a subsampling method and selection of physical quantities. However, errors which may arise throughout the determination of these temporal indices/ratio calculations (T-IRC) have not been quantified. The purpose of the current study was therefore to estimate the reliability of T-IRC following semi-automatic total mapping (SATM). Using a repeated-measures design, two experienced therapists performed three subsampling sessions on three left and right pedobarographic footprints of ten healthy participants. Following the subsampling, six T-IRC were calculated: Rearfoot-Forefoot_fti, Rearfoot-Midfoot_fti, Forefoot medial/lateral_fti, First ray_fti, Metatarsal 1-Metatarsal 5_fti, Foot medial-lateral_fti. Patterns of the T-IRC were found to be consistent and in good agreement with corresponding knowledge from the literature. The inter-session errors of both therapists were similar in pattern and magnitude. The lowest peak inter-therapist error was found in the First ray_fti (6.5 a.u.) whereas the highest peak inter-therapist error was observed in the Forefoot medial/lateral_fti (27.0 a.u.) The magnitude of the inter-session and inter-therapist error varied over time, precluding the calculation of a simple numerical value for the error. The difference between both error parameters of all T-IRC was negligible which underscores the repeatability of the SATM protocol. The current study reports consistent patterns for six T-IRC and similar inter-session and inter-therapist error. The proposed SATM protocol and the T-IRC may therefore serve as basis for functional interpretation of footprint data. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Measurement of the initial conversion ratio in AQUILON and EDF 2 reactors

    International Nuclear Information System (INIS)

    Bergeron, J.; Le Baud, P.; Sautiez, B.

    1968-01-01

    In natural uranium fuelled reactors, it is important to know the initial conversion ratio, i.e. the ratio of uranium 238 absorption to uranium 235 destruction. The separation of absorption products from fission products is a difficult feature in the measurement of the conversion ratio. A physical method was chosen, the γγ coincidence technique which uses the properties of the decay scheme of neptunium 239 and allows the neptunium activity to be separated from the fission product activity, with some corrections. Detectors of natural uranium are used. The accuracy obtained in the measurements is of the order of 2%. (authors) [fr

  13. Self-dissimilarity as a High Dimensional Complexity Measure

    Science.gov (United States)

    Wolpert, David H.; Macready, William

    2005-01-01

    For many systems characterized as "complex" the patterns exhibited on different scales differ markedly from one another. For example the biomass distribution in a human body "looks very different" depending on the scale at which one examines it. Conversely, the patterns at different scales in "simple" systems (e.g., gases, mountains, crystals) vary little from one scale to another. Accordingly, the degrees of self-dissimilarity between the patterns of a system at various scales constitute a complexity "signature" of that system. Here we present a novel quantification of self-dissimilarity. This signature can, if desired, incorporate a novel information-theoretic measure of the distance between probability distributions that we derive here. Whatever distance measure is chosen, our quantification of self-dissimilarity can be measured for many kinds of real-world data. This allows comparisons of the complexity signatures of wholly different kinds of systems (e.g., systems involving information density in a digital computer vs. species densities in a rain-forest vs. capital density in an economy, etc.). Moreover, in contrast to many other suggested complexity measures, evaluating the self-dissimilarity of a system does not require one to already have a model of the system. These facts may allow self-dissimilarity signatures to be used a s the underlying observational variables of an eventual overarching theory relating all complex systems. To illustrate self-dissimilarity we present several numerical experiments. In particular, we show that underlying structure of the logistic map is picked out by the self-dissimilarity signature of time series produced by that map

  14. Are implicit self-esteem measures valid for assessing individual and cultural differences?

    Science.gov (United States)

    Falk, Carl F; Heine, Steven J; Takemura, Kosuke; Zhang, Cathy X J; Hsu, Chih-Wei

    2015-02-01

    Our research utilized two popular theoretical conceptualizations of implicit self-esteem: 1) implicit self-esteem as a global automatic reaction to the self; and 2) implicit self-esteem as a context/domain specific construct. Under this framework, we present an extensive search for implicit self-esteem measure validity among different cultural groups (Study 1) and under several experimental manipulations (Study 2). In Study 1, Euro-Canadians (N = 107), Asian-Canadians (N = 187), and Japanese (N = 112) completed a battery of implicit self-esteem, explicit self-esteem, and criterion measures. Included implicit self-esteem measures were either popular or provided methodological improvements upon older methods. Criterion measures were sampled from previous research on implicit self-esteem and included self-report and independent ratings. In Study 2, Americans (N = 582) completed a shorter battery of these same types of measures under either a control condition, an explicit prime meant to activate the self-concept in a particular context, or prime meant to activate self-competence related implicit attitudes. Across both studies, explicit self-esteem measures far outperformed implicit self-esteem measures in all cultural groups and under all experimental manipulations. Implicit self-esteem measures are not valid for individual or cross-cultural comparisons. We speculate that individuals may not form implicit associations with the self as an attitudinal object. © 2013 Wiley Periodicals, Inc.

  15. Media Exposure in Low-Income Preschool-Aged Children Is Associated with Multiple Measures of Self-Regulatory Behavior.

    Science.gov (United States)

    Munzer, Tiffany G; Miller, Alison L; Peterson, Karen E; Brophy-Herb, Holly E; Horodynski, Mildred A; Contreras, Dawn; Sturza, Julie; Lumeng, Julie C; Radesky, Jenny

    2018-05-01

    Excessive screen media exposure in childhood is associated with parent-reported self-regulation difficulties. No studies have used laboratory-based or teacher-reported measures of child self-regulatory behaviors. This study examines cross-sectional associations between preschooler screen media exposure and multiple measures of self-regulatory behaviors. Preintervention data were used from 541 preschoolers in the Growing Healthy study, an obesity prevention trial (2011-2015). Screen media exposure was measured by daily screen media exposure (hr/d), television (TV) in the bedroom, frequency of background TV, and TV with meals (1 = rarely/never, 4 = frequently). Child self-regulatory behaviors were measured by the following: child ability to delay gratification, a standardized waiting paradigm; teacher-reported Social Competence and Behavior Evaluation; and parent-reported difficult temperament on the Child Behavior Questionnaire (CBQ). Multivariate regression analyses modeled screen media exposure predicting each self-regulatory measure, adjusting for child age, sex, parent age, education, marital status, income-to-needs ratio, number of adults in household, parent depressive symptoms, and sensitivity. Children were aged 4.1 years (SD = 0.5), parents were aged 29.6 years (SD = 6.8), 48% had high school education or less, and 67% were married. Daily screen media exposure and background TV were associated with weaker observed self-regulation (β: -10.30 seconds for each hr/d media, -12.63 seconds for 1-point increase, respectively). Background TV and TV with meals were associated with greater parent-reported difficult temperament (β: 0.04 and 0.05 CBQ, respectively, for 1-point increase). Greater screen media exposure had small but significant associations with weaker observed and parent-reported, but not teacher-reported, self-regulatory behaviors. Longitudinal studies are needed to determine the directionality of associations.

  16. The Nitrate/Perchlorate Ratio on Mars as an Indicator for Habitability

    Science.gov (United States)

    Stern, J. C.; Sutter, B.; McKay, C. P.; Navarro-Gonzalex, R.; Freissinet, C.; Conrad, P. G.; Mahaffy, P. R.; Archer, P. D., Jr.; Ming, D. W.; Niles, P. B.; hide

    2015-01-01

    Discovery of indigenous martian nitrogen in Mars surface materials has important implications for habitability and the potential development of a nitrogen cycle at some point in martian history. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected evolved nitric oxide (NO) gas during pyrolysis of scooped aeolian sediments and drilled mudstone acquired in Gale Crater. The detection of NO suggests an indigenous source of fixed N, and may indicate a mineralogical sink for atmospheric N2 in the form of nitrate. The ratio of nitrate to oxychlorine species (e.g. perchlorate) may provide insight into the extent of development of a nitrogen cycle on Mars.

  17. SOCIAL MEASUREMENT OF YOUTH’S HEALTH: DESIGNING OF INDICATORS OF COMPLEX SOCIOLOGICAL RESEARCH

    Directory of Open Access Journals (Sweden)

    Vitalii Valeriyevich Kulish

    2017-06-01

    Full Text Available Purpose. The article is devoted to solving the problem of social measurement of modern youth’s health. The subject of the analysis is the content of the concept, characteristics and indicators of the social health of young people, which enable using sociological research’ methods to measure a given status of the younger generation in contemporary Russian society. The purpose of this work is to define the theoretical and methodological foundations of the sociological analysis of the young people social health and to substantiate its main indicators in the tools of complex sociological research. Methodology of the study. The basis of the research is formed by the system approach, the complex approach, the logical-conceptual method and general scientific methods of research: comparative analysis, system analysis, construction of social indicators, modeling. Results. The social health of young people is defined through the category “status” and is considered as an integrated indicator of the social quality of the younger generation. It is substantiated that the social health of youth is a status of socio-demographic community in which it is able not only to adapt to the changing conditions of the social environment but is also ready to transform actively the surrounding reality, having the potential to resist destructive social phenomena and processes. The main indicators that allow measuring the social health of young people by sociological methods are determined: adaptability in the social environment, social activity in all spheres of public life, social orientation and significance of activity, behavior regulativity by social norms and universal values, creativity of thinking and behavior, readiness for social integration and self-development. A system of social indicators and indicators for conducting a sociological study of social health in historical memory, value orientations and everyday practices of young people has been developed.

  18. Validation of Self-Report Impairment Measures for Section III Obsessive-Compulsive and Avoidant Personality Disorders.

    Science.gov (United States)

    Liggett, Jacqueline; Carmichael, Kieran L C; Smith, Alexander; Sellbom, Martin

    2017-01-01

    This study examined the validity of newly developed disorder-specific impairment scales (IS), modeled on the Level of Personality Functioning Scale, for obsessive-compulsive (OCPD) and avoidant (AvPD) personality disorders. The IS focused on content validity (items directly reflected the disorder-specific impairments listed in DSM-5 Section III) and severity of impairment. A community sample of 313 adults completed personality inventories indexing the DSM-5 Sections II and III diagnostic criteria for OCPD and AvPD, as well as measures of impairment in the domains of self- and interpersonal functioning. Results indicated that both impairment measures (for AvPD in particular) showed promise in their ability to measure disorder-specific impairment, demonstrating convergent validity with their respective Section II counterparts and discriminant validity with their noncorresponding Section II disorder and with each other. The pattern of relationships between scores on the IS and scores on external measures of personality functioning, however, did not indicate that it is useful to maintain a distinction between impairment in the self- and interpersonal domains, at least for AvPD and OCPD.

  19. A New Measure to Assess Linguistic Self-Esteem in Adolescent Latino Bilinguals

    Science.gov (United States)

    Neugebauer, Sabina Rak

    2011-01-01

    Present conceptualizations and measures of self-esteem do not account for linguistic self-esteem, an aspect of the self specifically relevant for bilingual students. This study examines the utility of a newly developed measure of linguistic self-esteem. This novel measure is compared with a commonly used self-esteem measure, two standardized…

  20. The adenoid-nasopharynx ratio. Its clinical value in children

    International Nuclear Information System (INIS)

    Zou Mingshun

    1997-01-01

    To evaluate the clinical usefulness of adenoid-nasopharynx ratio (A/N ratio) measured on nasopharyngeal lateral plain film, 106 clinical cases of secretory otitis media were selected to measure the A/N ratio before treatment. For patients with A/N ratio of 0.50-0.70, the symptoms improved distinctly after conservative treatment, but one half of patients with A/N ratio ≥ 0.71 required adenoidectomy. A/N ratio is a practical and convenient method for evaluation of the adenoid. A/N ratio ≥ 0.71 indicates pathological enlarged adenoid

  1. Detecting vocal fatigue in student singers using acoustic measures of mean fundamental frequency, jitter, shimmer, and harmonics-to-noise ratio

    Science.gov (United States)

    Sisakun, Siphan

    2000-12-01

    The purpose of this study is to explore the ability of four acoustic parameters, mean fundamental frequency, jitter, shimmer, and harmonics-to-noise ratio, to detect vocal fatigue in student singers. The participants are 15 voice students, who perform two distinct tasks, data collection task and vocal fatiguing task. The data collection task includes the sustained vowel /a/, reading a standard passage, and self-rate on a vocal fatigue form. The vocal fatiguing task is the vocal practice of musical scores for a total of 45 minutes. The four acoustic parameters are extracted using the software EZVoicePlus. The data analyses are performed to answer eight research questions. The first four questions relate to correlations of the self-rating scale and each of the four parameters. The next four research questions relate to differences in the parameters over time using one-factor repeated measures analysis of variance (ANOVA). The result yields a proposed acoustic profile of vocal fatigue in student singers. This profile is characterized by increased fundamental frequency; slightly decreased jitter; slightly decreased shimmer; and slightly increased harmonics-to-noise ratio. The proposed profile requires further investigation.

  2. 2D:4D digit ratio predicts delay of gratification in preschoolers.

    Directory of Open Access Journals (Sweden)

    Sergio Da Silva

    Full Text Available We replicate the Stanford marshmallow experiment with a sample of 141 preschoolers and find a correlation between lack of self-control and 2D:4D digit ratio. Children with low 2D:4D digit ratio are less likely to delay gratification. Low 2D:4D digit ratio may indicate high fetal testosterone. If this hypothesis is true, our finding means high fetal testosterone children are less likely to delay gratification.

  3. Influence of conservative corrections on parameter estimation for extreme-mass-ratio inspirals

    International Nuclear Information System (INIS)

    Huerta, E. A.; Gair, Jonathan R.

    2009-01-01

    We present an improved numerical kludge waveform model for circular, equatorial extreme-mass-ratio inspirals (EMRIs). The model is based on true Kerr geodesics, augmented by radiative self-force corrections derived from perturbative calculations, and in this paper for the first time we include conservative self-force corrections that we derive by comparison to post-Newtonian results. We present results of a Monte Carlo simulation of parameter estimation errors computed using the Fisher matrix and also assess the theoretical errors that would arise from omitting the conservative correction terms we include here. We present results for three different types of system, namely, the inspirals of black holes, neutron stars, or white dwarfs into a supermassive black hole (SMBH). The analysis shows that for a typical source (a 10M · compact object captured by a 10 6 M · SMBH at a signal to noise ratio of 30) we expect to determine the two masses to within a fractional error of ∼10 -4 , measure the spin parameter q to ∼10 -4.5 , and determine the location of the source on the sky and the spin orientation to within 10 -3 steradians. We show that, for this kludge model, omitting the conservative corrections leads to a small error over much of the parameter space, i.e., the ratio R of the theoretical model error to the Fisher matrix error is R<1 for all ten parameters in the model. For the few systems with larger errors typically R<3 and hence the conservative corrections can be marginally ignored. In addition, we use our model and first-order self-force results for Schwarzschild black holes to estimate the error that arises from omitting the second-order radiative piece of the self-force. This indicates that it may not be necessary to go beyond first order to recover accurate parameter estimates.

  4. Probabilistic quantitative microbial risk assessment model of norovirus from wastewater irrigated vegetables in Ghana using genome copies and fecal indicator ratio conversion for estimating exposure dose.

    Science.gov (United States)

    Owusu-Ansah, Emmanuel de-Graft Johnson; Sampson, Angelina; Amponsah, Samuel K; Abaidoo, Robert C; Dalsgaard, Anders; Hald, Tine

    2017-12-01

    The need to replace the commonly applied fecal indicator conversions ratio (an assumption of 1:10 -5 virus to fecal indicator organism) in Quantitative Microbial Risk Assessment (QMRA) with models based on quantitative data on the virus of interest has gained prominence due to the different physical and environmental factors that might influence the reliability of using indicator organisms in microbial risk assessment. The challenges facing analytical studies on virus enumeration (genome copies or particles) have contributed to the already existing lack of data in QMRA modelling. This study attempts to fit a QMRA model to genome copies of norovirus data. The model estimates the risk of norovirus infection from the intake of vegetables irrigated with wastewater from different sources. The results were compared to the results of a corresponding model using the fecal indicator conversion ratio to estimate the norovirus count. In all scenarios of using different water sources, the application of the fecal indicator conversion ratio underestimated the norovirus disease burden, measured by the Disability Adjusted Life Years (DALYs), when compared to results using the genome copies norovirus data. In some cases the difference was >2 orders of magnitude. All scenarios using genome copies met the 10 -4 DALY per person per year for consumption of vegetables irrigated with wastewater, although these results are considered to be highly conservative risk estimates. The fecal indicator conversion ratio model of stream-water and drain-water sources of wastewater achieved the 10 -6 DALY per person per year threshold, which tends to indicate an underestimation of health risk when compared to using genome copies for estimating the dose. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Measuring individual work performance: identifying and selecting indicators.

    Science.gov (United States)

    Koopmans, Linda; Bernaards, Claire M; Hildebrandt, Vincent H; de Vet, Henrica C W; van der Beek, Allard J

    2014-01-01

    Theoretically, individual work performance (IWP) can be divided into four dimensions: task performance, contextual performance, adaptive performance, and counterproductive work behavior. However, there is no consensus on the indicators used to measure these dimensions. This study was designed to (1) identify indicators for each dimension, (2) select the most relevant indicators, and (3) determine the relative weight of each dimension in ratings of work performance. IWP indicators were identified from multiple research disciplines, via literature, existing questionnaires, and expert interviews. Subsequently, experts selected the most relevant indicators per dimension and scored the relative weight of each dimension in ratings of IWP. In total, 128 unique indicators were identified. Twenty-three of these indicators were selected by experts as most relevant for measuring IWP. Task performance determined 36% of the work performance rating, while the other three dimensions respectively determined 22%, 20% and 21% of the rating. Notable consensus was found on relevant indicators of IWP, reducing the number from 128 to 23 relevant indicators. This provides an important step towards the development of a standardized, generic and short measurement instrument for assessing IWP.

  6. New Measurement of the π → eν branching ratio

    International Nuclear Information System (INIS)

    Dixit, M.S.; Bryman, D.A.; Dubois, R.; Numao, T.; Olaniyi, B.; Olin, A.; Berghofer, D.; Poutissou, J.-M.; Macdonald, J.A.

    1982-11-01

    A new measurement of the π → eν branching ratio yields GAMMA(π→eν + π→eνγ) / GAMMA(π→μν + π→γνμ) = (1.218 +- 0.014) x 10 -4 . The measured value is in good agreement with the standard model prediction incorporating electron-muon universality

  7. Mass spectrometric measurement of urinary kynurenine-to-tryptophan ratio in children with and without urinary tract infection.

    Science.gov (United States)

    Yarbrough, Melanie L; Briden, Kelleigh E; Mitsios, John V; Weindel, Annette L; Terrill, Cindy M; Hunstad, David A; Dietzen, Dennis J

    2018-04-19

    Indoleamine-2,3-dioxygenase (IDO) catalyzes the first step of tryptophan (Trp) catabolism, yielding kynurenine (Kyn) metabolites. The kynurenine-to-tryptophan (K/T) ratio is used as a surrogate for biological IDO enzyme activity. IDO expression is increased during Escherichia coli urinary tract infection (UTI). Thus, our objective was to develop a method for measurement of Kyn/Trp ratio in human blood and urine and evaluate its use as a biomarker of UTI. A mass spectrometric method was developed to measure Trp and Kyn in serum and urine specimens. The method was applied to clinical urine specimens from symptomatic pediatric patients with laboratory-confirmed UTI or other acute conditions and from healthy controls. The liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was linear to 500 μmol/L for both Trp and Kyn. Imprecision ranged from 5 to 15% for Trp and 6-20% for Kyn. Analytical recoveries of Trp and Kyn ranged from 96 to 119% in serum and 90-97% in urine. No correlation was found between the K/T ratio and circulating IDO mass (r = 0.110) in serum. Urinary Kyn and Trp in the pediatric test cohort demonstrated elevations in the K/T ratio in symptomatic patients with UTI (median 13.08) and without UTI (median 14.38) compared to healthy controls (median 4.93; p < 0.001 for both comparisons). No significant difference in K/T ratio was noted between symptomatic patients with and without UTI (p = 0.84). Measurement of Trp and Kyn by LC-MS/MS is accurate and precise in serum and urine specimens. While urinary K/T ratio is not a specific biomarker for UTI, it may represent a general indicator of a systemic inflammatory process. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. h-index, h-type Indices, and the Role of Corrected Quality Ratio

    Directory of Open Access Journals (Sweden)

    Tahira, Muzammil

    2014-12-01

    Full Text Available This study examines the foremost concerns related to most noted research performance index. The most popular and widely acceptable h-index underestimates the highly visible scientist, the middle order group, due to citation distribution issues. The study addresses this issue and uses 'Corrected Quality Ratio' (CQ to check the implicit underpinnings as evident in h-index. CQ helps to incorporate the aspects of a good research performance indicator. This simple revision performs more intimately and logically to gauge the broader research impact for all groups and highly visible scientists with less statistical error.

  9. Piezo-sensor self-diagnostics using electrical impedance measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Park, G. H. (Gyu Hae); Farrar, C. R. (Charles R.); Rutherford, A. C. (Amanda C.); Robertson, A. N. (Amy N.)

    2004-01-01

    This paper present the piezoelectric sensor self-diagnostic procedure that performs in-situ monitoring of the operational status of piezoelectric materials (PZT) used for sensors and actuators in structural health monitoring (SHM) applications. The use of active-sensing piezoelectric materials has received considerable attention in the SHM community. A critical aspect of the piezoelectric active-sensing technologies is that usually large numbers of distributed sensors and actuators are needed to perform the required monitoring process. The sensor/actuator self-diagnostic procedure, where the sensors/actuators are confirmed to be functioning properly during operation, is therefore a critical component to successfully complete the SHM process and to minimize the false indication regarding the structural health. The basis of this procedure is to track the changes in the capacitive value of piezoelectric materials resulting from the sensor failure, which is manifested in the imaginary part of the measured electrical admittances. Furthermore, through the analytical and experimental investigation, it is confirmed that the bonding layer between the PZT and a host structure significantly contributes to the measured capacitive values. Therefore, by monitoring the imaginary part of the admittances, one can quantitatively assess the degradation of the mechanical/electrical properties of the PZT and its attachment to a host structure. This paper concludes with an experimental example to demonstrate the feasibility of the proposed sensor-diagnostic procedure.

  10. Mixed carboranethiol self-assembled monolayers on gold surfaces

    Science.gov (United States)

    Yavuz, Adem; Sohrabnia, Nima; Yilmaz, Ayşen; Danışman, M. Fatih

    2017-08-01

    Carboranethiol self-assembled monolayers on metal surfaces have been shown to be very convenient systems for surface engineering. Here we have studied pure and mixed self-assembled monolayers (SAMs) of three different carboranethiol (CT) isomers on gold surfaces. The isomers were chosen with dipole moments pointing parallel to (m-1-carboranethiol, M1), out of (m-9-carboranethiol, M9) and into (o-1-carboranethiol, O1) the surface plane, in order to investigate the effect of dipole moment orientation on the film properties. In addition, influence of the substrate surface morphology on the film properties was also studied by using flame annealed (FA) and template stripped (TS) gold surfaces. Contact angle measurements indicate that in M1/M9 and M1/O1 mixed SAMs, M1 is the dominant species on the surface even for low M1 ratio in the growth solution. Whereas for O1/M9 mixed SAMs no clear evidence could be observed indicating dominance of one of the species over the other one. Though contact angle values were lower and hysteresis values were higher for SAMs grown on TS gold surfaces, the trends in the behavior of the contact angles with changing mixing ratio were identical for SAMs grown on both substrates. Atomic force microscopy images of the SAMs on TS gold surfaces indicate that the films have similar morphological properties regardless of mixing ratio.

  11. Measuring the Complexity of Self-Organizing Traffic Lights

    Directory of Open Access Journals (Sweden)

    Darío Zubillaga

    2014-04-01

    Full Text Available We apply measures of complexity, emergence, and self-organization to an urban traffic model for comparing a traditional traffic-light coordination method with a self-organizing method in two scenarios: cyclic boundaries and non-orientable boundaries. We show that the measures are useful to identify and characterize different dynamical phases. It becomes clear that different operation regimes are required for different traffic demands. Thus, not only is traffic a non-stationary problem, requiring controllers to adapt constantly; controllers must also change drastically the complexity of their behavior depending on the demand. Based on our measures and extending Ashby’s law of requisite variety, we can say that the self-organizing method achieves an adaptability level comparable to that of a living system.

  12. The Crossmatch/Issue Ratio:  Use of a Novel Quality Indicator and Results of an International Survey on RBC Crossmatching and Issuing Practices

    DEFF Research Database (Denmark)

    Yazer, Mark H; Alcantara, Ramir; Beizai, Pouneh

    2016-01-01

    OBJECTIVES: To understand the worldwide scope of RBC crossmatching and issuing practices and measure efficiency using a novel quality indicator, the crossmatch/issue (C/I) ratio. METHODS: An electronic survey was disseminated to hospital transfusion services collecting details about RBC...... crossmatching and issuing practices. Respondents were asked to enumerate the number of RBCs crossmatched and issued at their institutions during the 2014 calendar year to calculate the C/I ratio. RESULTS: Fifty-two survey responses were received, mostly from North American transfusion services (28/52, 54......%). The electronic crossmatch was the most common technique (n = 29), and most respondents performed the crossmatch at the time that an order for RBCs was received in the transfusion service (even if an order to issue the RBCs was not received). Data to calculate the C/I ratio were supplied by 22 respondents...

  13. The spleen-liver uptake ratio in liver scan: review of its measurement and correlation between hemodynamical changes of the liver in portal hypertension

    International Nuclear Information System (INIS)

    Lee, S. Y.; Chung, Y. A.; Chung, H. S.; Lee, H. G.; Kim, S. H.; Chung, S. K.

    1999-01-01

    We analyzed correlation between changes of the Spleen-Liver Ratio in liver scintigram and hemodynamical changes of the liver in overall grades of portal hypertension by non-invasive, scintigraphic method. And the methods for measurement of the Spleen-Liver Ratio were also reviewed. Hepatic scintiangiograms for 120 seconds with 250-333 MBq of 99mTc-Sn-phytate followed by liver scintigrams were performed in 62 patients group consisted with clinically proven norma and various diffuse hepatocellular diseases. Hepatic Perfusion indices were calculated from the Time-Activity Curves of hepatic scintiangiograms. Each Spleen-Liver Ratios of maximum, average and total counts within ROIs of the liver and spleen from both anterior and posterior liver scintigrams and their geometrical means were calculated. Linear correlations between each Spleen-Liver Ratios and Hepatic Perfusion indices were evaluated. There was strong correlation (y=0.0002x 2 -0.0049x+0.2746, R=0.8790, p<0.0001) between Hepatic Perfusion Indices and Spleen-Liver Ratios calculated from posterior maxium counts of the liver scintigrams. Weaker correlations with either geometrical means of maximum and average count methods (R=0.8101, 0.7268, p<0.0001) or average counts of both posterior and anterior veiws (R=0.8134, 0.6200, p<0.0001) were noted. We reconfirmed that changes of Spleen-Liver Ratio in liver scintigrams represent hemodynamical changes in portal hypertension of diffuse hepatocellular diseases. Among them, the posterior Spleen-Liver Ratio measured by maximum counts will give the best information. And matching with Hepatic Perfusion index will be another useful index to evaluate characteristics splenic extraction coefficient of a certain radiocolloid for liver scintigram

  14. Chronic condition self-management surveillance: what is and what should be measured?

    Science.gov (United States)

    Ruiz, Sarah; Brady, Teresa J; Glasgow, Russell E; Birkel, Richard; Spafford, Michelle

    2014-06-19

    The rapid growth in chronic disease prevalence, in particular the prevalence of multiple chronic conditions, poses a significant and increasing burden on the health of Americans. Maximizing the use of proven self-management (SM) strategies is a core goal of the US Department of Health and Human Services. Yet, there is no systematic way to assess how much SM or self-management support (SMS) is occurring in the United States. The purpose of this project was to identify appropriate concepts or measures to incorporate into national SM and SMS surveillance. A multistep process was used to identify candidate concepts, assess existing measures, and select high-priority concepts for further development. A stakeholder survey, an environmental scan, subject matter expert feedback, and a stakeholder priority-setting exercise were all used to select the high-priority concepts for development. The stakeholder survey gathered feedback on 32 candidate concepts; 9 concepts were endorsed by more than 66% of respondents. The environmental scan indicated few existing measures that adequately reflected the candidate concepts, and those that were identified were generally specific to a defined condition and not gathered on a population basis. On the basis of the priority setting exercises and environmental scan, we selected 1 concept from each of 5 levels of behavioral influence for immediate development as an SM or SMS indicator. The absence of any available measures to assess SM or SMS across the population highlights the need to develop chronic condition SM surveillance that uses national surveys and other data sources to measure national progress in SM and SMS.

  15. The state of measurement of self-esteem of African American women.

    Science.gov (United States)

    Hatcher, Jennifer

    2007-07-01

    This article critically reviews the state of measurement of self-esteem in African American women. The Rosenberg Self-Esteem Scale, the Tennessee Self-Concept Scale, and the Coopersmith Self-Esteem Inventory are three commonly used measures. However, their validity for African American women has not been adequately tested. Given the unique nature of the self-esteem of this group, related to experiences of racism and sexism, the accurate measurement of this construct is important. This review provided support for the internal consistency of each measure with alpha coefficients ranging from .74 to .87. However, the validity of the measures was not fully supported. Suggestions for further research specific to the unique needs of this population are discussed.

  16. Neither self-reported ethnicity nor declared family origin are reliable indicators of genomic ancestry.

    Science.gov (United States)

    Ramos, Bruna Ribeiro de Andrade; D'Elia, Maria Paula Barbieri; Amador, Marcos Antônio Trindade; Santos, Ney Pereira Carneiro; Santos, Sidney Emanuel Batista; da Cruz Castelli, Erick; Witkin, Steven S; Miot, Hélio Amante; Miot, Luciane Donida Bartoli; da Silva, Márcia Guimarães

    2016-06-01

    Ancestry information can be useful in investigations of diseases with a genetic or infectious background. As the Brazilian population is highly admixed physical traits tend to be poor indicators of ancestry. The assessment of ancestry by ancestry informative markers (AIMs) can exclude the subjectivity of self-declared ethnicity and reported family origin. We aimed to evaluate the reliability of self-reported ethnicity or reported family origin as indicators of genomic ancestry in a female population from the Southeast of Brazil. Two cohorts were included: 404 women asked to self-report their ethnicity (Pop1) and 234 women asked to report their family's origin (Pop2). Identification of AIMs was performed using a panel of 61 markers and results were plotted against parental populations-Amerindian, Western European and Sub-Saharan African-using Structure v2.3.4. In Pop1 57.4 % of women self-reported as white, 34.6 % as brown and 8.0 % as black. Median global European, Amerindian and African contributions were 66.8, 12.6 and 16.6 %. In Pop2, 66.4 % of women declared European origin, 23.9 % African origin and 26.9 % Amerindian. Median global European, Amerindian and African contributions were 80.8, 7.3 and 7.6 %, respectively. Only 31.0 and 21.0 % of the global variation in African and European contributions, respectively, could be explained by self-reported ethnicity and reported family origin only accounted for 20.0 and 5.0 % of the variations observed in African and European ancestries, respectively. Amerindian ancestry did not influence self-reported ethnicity or declared family origin. Neither self-reported ethnicity nor declared family origin are reliable indicators of genomic ancestry in these Brazilian populations.

  17. Magnetic Resonance Signal Intensity Ratio Measurement Before Uterine Artery Embolization

    DEFF Research Database (Denmark)

    Duvnjak, Stevo; Ravn, Pernille; Green, Anders

    2017-01-01

    , 52 patients were included in this prospective study. The SI ratio before UFE was calculated using circular region of interests placed on the dominant fibroid and the iliac muscle. The SI fibroid-to-iliac muscle ratio was calculated as SI of the dominant fibroid/SI of the iliac muscle on T1-, T2......-, and T1 post-contrast-weighted sequences. The dominant fibroid volume was measured and analyzed before and after UFE. RESULTS: In all, 46 patients who completed the three-month follow-up MRI were available for analysis. The correlation between SI fibroid-to-muscle ratio at the T2-weighted sequence...... positive correlation (r = 0.439, p T2-weighted sequence. The area under curve (AUC) for SI fibroid-to-muscle ratio on T2-weighted sequence was 0.776. For the other parameters, the AUC values were 0.512, 0.671, and 0.578, respectively. CONCLUSION: SI...

  18. Computer Self-Efficacy: A Practical Indicator of Student Computer Competency in Introductory IS Courses

    Directory of Open Access Journals (Sweden)

    Rex Karsten

    1998-01-01

    Full Text Available Students often receive their first college-level computer training in introductory information systems courses. Students and faculty frequently expect this training to develop a level of student computer competence that will support computer use in future courses. In this study, we applied measures of computer self-efficacy to students in a typical introductory IS course. The measures provided useful evidence that student perceptions of their ability to use computers effectively in the future significantly improved as a result of their training experience. The computer self-efficacy measures also provided enhanced insight into course-related factors of practical concern to IS educators. Study results also suggest computer self-efficacy measures may be a practical and informative means of assessing computer-training outcomes in the introductory IS course context

  19. Ozone mixing ratios inside tropical deep convective clouds from OMI satellite measurements

    Directory of Open Access Journals (Sweden)

    J. R. Ziemke

    2009-01-01

    Full Text Available We have developed a new technique for estimating ozone mixing ratio inside deep convective clouds. The technique uses the concept of an optical centroid cloud pressure that is indicative of the photon path inside clouds. Radiative transfer calculations based on realistic cloud vertical structure as provided by CloudSat radar data show that because deep convective clouds are optically thin near the top, photons can penetrate significantly inside the cloud. This photon penetration coupled with in-cloud scattering produces optical centroid pressures that are hundreds of hPa inside the cloud. We combine measured column ozone and the optical centroid cloud pressure derived using the effects of rotational-Raman scattering to estimate O3 mixing ratio in the upper regions of deep convective clouds. The data are obtained from the Ozone Monitoring Instrument (OMI onboard NASA's Aura satellite. Our results show that low O3 concentrations in these clouds are a common occurrence throughout much of the tropical Pacific. Ozonesonde measurements in the tropics following convective activity also show very low concentrations of O3 in the upper troposphere. These low amounts are attributed to vertical injection of ozone poor oceanic boundary layer air during convection into the upper troposphere followed by convective outflow. Over South America and Africa, O3 mixing ratios inside deep convective clouds often exceed 50 ppbv which are comparable to mean background (cloud-free amounts and are consistent with higher concentrations of injected boundary layer/lower tropospheric O3 relative to the remote Pacific. The Atlantic region in general also consists of higher amounts of O3 precursors due to both biomass burning and lightning. Assuming that O3 is well mixed (i.e., constant mixing ratio with height up to the tropopause, we can estimate the stratospheric column O3 over

  20. Measurement of the atmospheric muon charge ratio with the OPERA detector

    International Nuclear Information System (INIS)

    Agafonova, N.; Boyarkin, V.; Enikeev, R.; Malgin, A.; Matveev, V.; Ryasny, V.; Ryazhskaya, O.; Yakushev, V.; Anokhina, A.; Galkin, V.I.; Nikitina, V.; Osedlo, V.; Publichenko, P.; Roganova, T.; Aoki, S.; Hara, T.; Rokujo, H.; Ariga, A.; Ariga, T.; Ereditato, A.; Juget, F.; Knuesel, J.; Kreslo, I.; Lutter, G.; Meisel, F.; Moser, U.; Pistillo, C.; Pretzl, K.; Vuilleumier, J.L.; Autiero, D.; Brugiere, T.; Cazes, A.; Chaussard, L.; Declais, Y.; Marteau, J.; Pennacchio, E.; Tran, T.; Badertscher, A.; Lazzaro, C.; Rubbia, A.; Strauss, T.; Bagulya, A.; Chernyavsky, M.; Goncharova, L.; Orlova, G.; Polukhina, N.; Starkov, N.; Vladimirov, M.; Bertolin, A.; Dal Corso, F.; Dusini, S.; Besnier, M.; Duchesneau, D.; Favier, J.; Pessard, H.; Zghiche, A.; Bick, D.; Ebert, J.; Ferber, T.; Goellnitz, C.; Hagner, C.; Lenkeit, J.; Oldorf, C.; Schmidt Parzefall, W.; Wonsak, B.; Zimmermann, R.; Bozza, C.; D'Amato, G.; Grella, G.; Policastro, G.; Rescigno, R.; Romano, G.; Sirignano, C.; Brugnera, R.; Garfagnini, A.; Kose, U.; Brunetti, G.; Giacomelli, G.; Giorgini, M.; Mauri, N.; Pozzato, M.; Sioli, M.; Tenti, M.; Buontempo, S.; Chukanov, A.; Di Capua, F.; Marotta, A.; Migliozzi, P.; Scotto Lavina, L.; Tioukov, V.; Chiarella, V.; Felici, G.; Grianti, F.; Paniccia, M.; Paoloni, A.; Spinetti, M.; Terranova, F.; Votano, L.; Chon-Sen, N.; Dracos, M.; Jollet, C.; Meregaglia, A.; Cozzi, M.; D'Ambrosio, N.; Di Giovanni, A.; Esposito, L.S.; Gustavino, C.; De Lellis, G.; Russo, A.; Strolin, P.; De Serio, M.; Fini, R.; Ieva, M.; Di Ferdinando, D.; Mandrioli, G.; Medinaceli, E.; Patrizii, L.; Sirri, G.; Di Marco, N.; Monacelli, P.; Park, B.D.; Park, I.G.; Pupilli, F.; Dmitrievski, S.; Gornushkin, Y.; Naumov, D.; Olchevski, A.; Sheshukov, A.; Zemskova, S.; Egorov, O.; Golubkov, D.; Rostovtseva, I.; Zaitsev, Y.; Frekers, D.; Pilipenko, V.; Fukuda, T.; Hamada, K.; Hoshino, K.; Kazuyama, M.; Komatsu, M.; Kubota, H.; Miyamoto, S.; Morishima, K.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Niwa, K.; Nonoyama, Y.; Sato, O.; Takahashi, S.; Yoshioka, T.; Yoshida, J.; Fukushima, C.; Kimura, M.; Matsuo, T.; Mikado, S.; Ogawa, S.; Shibuya, H.; Goldberg, J.; Guler, M.; Tolun, P.; Tufanli, S.; Hierholzer, M.; Jakovcic, K.; Klicek, B.; Ljubicic, A.; Stipcevic, M.; Kim, S.H.; Song, J.S.; Yoon, C.S.; Kodama, K.; Longhin, A.; Stanco, L.; Muciaccia, M.T.; Pastore, A.; Simone, S.; Rosa, G.; Schembri, A.; Sato, Y.; Tezuka, I.; Schroeder, H.; Vilain, P.; Wilquet, G.

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the atmospheric muon charge ratio R μ =N μ + /N μ - in the TeV energy region. We analyzed 403069 atmospheric muons corresponding to 113.4 days of lifetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the R μ dependence on the primary composition. The measured R μ values were corrected taking into account the charge-misidentification errors. Data have also been grouped in five bins of the ''vertical surface energy'' E μ cos θ. A fit to a simplified model of muon production in the atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum. (orig.)

  1. In vivo dissolution measurement with indium-111 summation peak ratios

    International Nuclear Information System (INIS)

    Jay, M.; Woodward, M.A.; Brouwer, K.R.

    1985-01-01

    Dissolution of [ 111 In]labeled tablets was measured in vivo in a totally noninvasive manner by using a modification of the perturbed angular correlation technique known as the summation peak ratio method. This method, which requires the incorporation of only 10-12 microCi into the dosage form, provided reliable dissolution data after oral administration of [ 111 In]lactose tablets. These results were supported by in vitro experiments which demonstrated that the dissolution rate as measured by the summation peak ratio method was in close agreement with the dissolution rate of salicylic acid in a [ 111 In]salicylic acid tablet. The method has the advantages of using only one detector, thereby avoiding the need for complex coincidence counting systems, requiring less radioactivity, and being potentially applicable to a gamma camera imaging system

  2. Objectively measured and self-reported leisure-time sedentary behavior and academic performance in youth: The UP&DOWN Study.

    Science.gov (United States)

    Esteban-Cornejo, Irene; Martinez-Gomez, David; Sallis, James F; Cabanas-Sánchez, Verónica; Fernández-Santos, Jorge; Castro-Piñero, Jose; Veiga, Oscar L

    2015-08-01

    To examine the associations of (i) objectively measured and self-reported sedentary behavior during leisure time with academic performance and (ii) patterns of sedentary behavior with academic performance. This study was conducted with 1146 youth aged 12.5±2.5years in Spain during 2011-2012. Leisure-time sedentary behavior during out-of-school hours was assessed by accelerometry and self-report. Academic performance was assessed through school grades. Objectively measured sedentary leisure-time was not significantly associated with academic performance. Time spent in Internet surfing, listening to music, and sitting without doing anything were negatively associated with all academic performance indicators (β ranging from -0.066 to -0.144; all pacademic indicators (β ranging from -0.085 to -0.148; all pacademic indicators (β ranging from 0.063 to 0.105; all pleisure-time, but not objectively measured sedentary leisure time, may influence academic performance. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Stable isotope ratios indicate diet and habitat use in New World monkeys.

    Science.gov (United States)

    Schoeninger, M J; Iwaniec, U T; Glander, K E

    1997-05-01

    This paper demonstrates the use of stable isotope ratios of carbon and nitrogen in animal tissue for indicating aspects of species behavioral strategy. We analyzed hair from individuals representing four species of New World monkeys (Alouatta palliata, the mantled howler; Ateles geoffroyi, the spider monkey; Cebus capucinus, the capuchin; and Brachyteles arachnoides, the woolly-spider monkey or muriqui) for delta 13C and delta 15N using previously developed methods. There are no significant differences in either carbon or nitrogen ratios between sexes, sampling year, or year of analysis. Seasonal differences in delta 13C reached a low level of significance but do not affect general patterns. Variation within species was similar to that recorded previously within single individuals. The omega 13C data show a bimodal distribution with significant difference between the means. The two monkey populations living in an evergreen forest were similar to each other and different from the other two monkey populations that inhabited dry, deciduous forests. This bimodal distribution is independent of any particular species' diet and reflects the level of leaf cover in the two types of forest. The delta 15N data display three significantly different modes. The omnivorous capuchins were most positive reflecting a trophic level offset. The spider monkeys and the muriquis were similar to one another and significantly more positive than the howlers. This distribution among totally herbivorous species correlates with the ingestion of legumes by the howler monkey population. In combination, these data indicate that museum-curated primate material can be analyzed to yield information on forest cover and diet in populations and species lacking behavioral data.

  4. High-precision branching-ratio measurement for the superallowed β+ emitter 74Rb

    Science.gov (United States)

    Dunlop, R.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Towner, I. S.; Andreoiu, C.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Glister, J.; Hackman, G.; Hadinia, B.; Leach, K. G.; Rand, E. T.; Starosta, K.; Tardiff, E. R.; Triambak, S.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.

    2013-10-01

    A high-precision branching-ratio measurement for the superallowed β+ decay of 74Rb was performed at the TRIUMF Isotope Separator and Accelerator (ISAC) radioactive ion-beam facility. The scintillating electron-positron tagging array (SCEPTAR), composed of 10 thin plastic scintillators, was used to detect the emitted β particles; the 8π spectrometer, an array of 20 Compton-suppressed HPGe detectors, was used for detecting γ rays that were emitted following Gamow-Teller and nonanalog Fermi β+ decays of 74Rb; and the Pentagonal Array of Conversion Electron Spectrometers (PACES), an array of 5 Si(Li) detectors, was employed for measuring β-delayed conversion electrons. Twenty-three excited states were identified in 74Kr following 8.241(4)×108 detected 74Rb β decays. A total of 58 γ-ray and electron transitions were placed in the decay scheme, allowing the superallowed branching ratio to be determined as B0=99.545(31)%. Combined with previous half-life and Q-value measurements, the superallowed branching ratio measured in this work leads to a superallowed ft value of 3082.8(65) s. Comparisons between this superallowed ft value and the world-average-corrected Ft¯ value, as well as the nonanalog Fermi branching ratios determined in this work, provide guidance for theoretical models of the isospin-symmetry-breaking corrections in this mass region.

  5. Low Platelet to White Blood Cell Ratio Indicates Poor Prognosis for Acute-On-Chronic Liver Failure.

    Science.gov (United States)

    Jie, Yusheng; Gong, Jiao; Xiao, Cuicui; Zhu, Shuguang; Zhou, Wenying; Luo, Juan; Chong, Yutian; Hu, Bo

    2018-01-01

    Background. Platelet to white blood cell ratio (PWR) was an independent prognostic predictor for outcomes in some diseases. However, the prognostic role of PWR is still unclear in patients with hepatitis B related acute-on-chronic liver failure (ACLF). In this study, we evaluated the clinical performances of PWR in predicting prognosis in HBV-related ACLF. Methods. A total of 530 subjects were recruited, including 97 healthy controls and 433 with HBV-related ACLF. Liver function, prothrombin time activity (PTA), international normalized ratio (INR), HBV DNA measurement, and routine hematological testing were performed at admission. Results . At baseline, PWR in patients with HBV-related ACLF (14.03 ± 7.17) was significantly decreased compared to those in healthy controls (39.16 ± 9.80). Reduced PWR values were clinically associated with the severity of liver disease and the increased mortality rate. Furthermore, PWR may be an inexpensive, easily accessible, and significant independent prognostic index for mortality on multivariate analysis (HR = 0.660, 95% CI: 0.438-0.996, p = 0.048) as well as model for end-stage liver disease (MELD) score. Conclusions . The PWR values were markedly decreased in ACLF patients compared with healthy controls and associated with severe liver disease. Moreover, PWR was an independent prognostic indicator for the mortality rate in patients with ACLF. This investigation highlights that PWR comprised a useful biomarker for prediction of liver severity.

  6. Variation in SPC/STC Ratio as an Indicator of Age: A Computer-aided Forensic Odontology

    Directory of Open Access Journals (Sweden)

    Priyanka Debta

    2010-01-01

    Results: Pearson correlation between SPC/STC ratio with different age group was found to be statistically significant. So, measurement of amount of secondary dentin seems to be reliable and rapid method in forensic odontology.

  7. Self-Selection Patterns of College Roommates as Identified by the Myers-Briggs Type Indicator.

    Science.gov (United States)

    Anchors, W. Scott; Hale, John, Jr.

    1985-01-01

    Investigated patterns and processes by which students (N=422) made unassisted roommate pairings within residence halls using the Myers-Briggs Type Indicator. Results indicated introverts, intuitives, feelers, and perceivers each tended to self-select. (BL)

  8. Self-similar measures in multi-sector endogenous growth models

    International Nuclear Information System (INIS)

    La Torre, Davide; Marsiglio, Simone; Mendivil, Franklin; Privileggi, Fabio

    2015-01-01

    We analyze two types of stochastic discrete time multi-sector endogenous growth models, namely a basic Uzawa–Lucas (1965, 1988) model and an extended three-sector version as in La Torre and Marsiglio (2010). As in the case of sustained growth the optimal dynamics of the state variables are not stationary, we focus on the dynamics of the capital ratio variables, and we show that, through appropriate log-transformations, they can be converted into affine iterated function systems converging to an invariant distribution supported on some (possibly fractal) compact set. This proves that also the steady state of endogenous growth models—i.e., the stochastic balanced growth path equilibrium—might have a fractal nature. We also provide some sufficient conditions under which the associated self-similar measures turn out to be either singular or absolutely continuous (for the three-sector model we only consider the singularity).

  9. Measuring Inpatient Rehabilitation Facility Quality of Care: Discharge Self-Care Functional Status Quality Measure.

    Science.gov (United States)

    Pardasaney, Poonam K; Deutsch, Anne; Iriondo-Perez, Jeniffer; Ingber, Melvin J; McMullen, Tara

    2018-06-01

    To describe the calculation and psychometric properties of the discharge self-care functional status quality measure implemented in the Centers for Medicare & Medicaid Services' (CMS) Inpatient Rehabilitation Facility (IRF) Quality Reporting Program on October 1, 2016. Medicare fee-for-service (FFS) patients from 38 IRFs that participated in the CMS Post-Acute Care Payment Reform Demonstration were included in this cohort study. Data came from the Continuity Assessment Record and Evaluation Item Set, IRF-Patient Assessment Instrument, and Medicare claims. For each patient, we calculated an expected discharge self-care score, risk-adjusted for demographic and baseline clinical characteristics. The performance score of each IRF equaled the percentage of patient stays where the observed discharge self-care score met or exceeded the expected score. We assessed the measure's discriminatory ability across IRFs and reliability. IRFs. Medicare FFS patients aged ≥21 years (N=4769). Not applicable. Facility-level discharge self-care quality measure performance score. A total of 4769 patient stays were included; 57% of stays were in women, and 12.1% were in patients aged quality measure showed strong reliability, with intraclass correlation coefficients of .91. The discharge self-care quality measure showed strong discriminatory ability and reliability, representing an important initial step in evaluation of IRF self-care outcomes. A wide range in performance scores suggested a gap in quality of care across IRFs. Future work should include testing the measure with nationwide data from all IRFs. Published by Elsevier Inc.

  10. Psychometric Characteristics of a New Scale for Measuring Self-efficacy in the Regulation of Gambling Behavior

    Directory of Open Access Journals (Sweden)

    Claudio Barbaranelli

    2017-06-01

    Full Text Available Since its introduction in 1977, self-efficacy has proven to be a fundamental predictor of positive adjustment and achievement in many domains. In problem gambling studies, self-efficacy has been defined mainly as an individual's ability to avoid gambling in risky situations. The interest in this construct developed mainly with regard to treatment approaches, where abstinence from gambling is required. Very little is known, however, regarding self-efficacy as a protective factor for problem gambling. This study aims to fill this gap, proposing a new self-efficacy scale which measures not only the ability to restrain oneself from gambling but also the ability to self-regulate one's gambling behavior. Two studies were conducted in which the data from two Italian prevalence surveys on problem gambling were considered. A total of about 6,000 participants were involved. In the first study, the psychometric characteristics of this new self-efficacy scale were investigated through exploratory and confirmatory factor analyses. The results indicated the presence of two different factors: self-efficacy in self-regulating gambling behavior and self-efficacy in avoiding risky gambling behavior. The second study confirmed the replicability of the two-factor solution and displayed high correlations among these two self-efficacy dimensions and different measures of gambling activities as well as other psychological variables related to gambling (gambling beliefs, gambling motivation, risk propensity, and impulsiveness. The results of logistic regression analyses showed the particular importance of self-regulating gaming behavior in explaining problem gambling as measured by Problem Gambling Severity Index and South Oaks Gambling Screen, thus proving the role of self-efficacy as a pivotal protective factor for problem gambling.

  11. Long distance elementary measurement of the radiation dose ratio produced by neutron activation

    International Nuclear Information System (INIS)

    Zhou Changgeng; Lou Benchao; Wu Chunlei; Hu Yonghong; Li Yan

    2009-04-01

    The working principle and the structure and performances of a long distance controllable individual radiation dose ratio instrument are described. The radiation dose ratio produced by neutron activation is elementarily measured by using this instrument in the neutron generator hall with high neutron yield. When neutron yield arrives to 2 x 10 11 s -1 , the radiation dose ratio produced by neutron activation is 99.9 μSv/h in 1 h after the generator being stopped. The radiation dose ratio is reduced to 24.4 μSv/h in 39 h after the generator being stopped. When neutron yield is 3.2 x 10 10 s -1 , the radiation dose ratio produced by neutron activation is 21.9 μSv/h in 36 min, after the generator being stopped. The measurement results may provide reference for physical experimenters and neutron generator operators. (authors)

  12. Differential Drell-Yan measurements and Z/top-pair cross section ratios

    CERN Document Server

    Zinser, Markus; The ATLAS collaboration

    2017-01-01

    Precision measurements of the Drell-Yan production of W and Z bosons at the LHC provide a benchmark of our understanding of perturbative QCD and electroweak processes and probe the proton structure in a unique way. The ATLAS collaboration performed a precision Z/gamma* measurement at a center of mass energy of 8 TeV in the di-lepton mass range up to the TeV scale. These are performed double-differentially in dilepton mass and rapidity or dilepton mass and rapidity separation. The measurements are compared to state-of-the-art theory calculations and are found to bring strong constraints on the high x partons and the poorly constrained photon content of the proton. Z cross sections are also measured at a center-of-mass energies of 8TeV and 13TeV, and cross-section ratios to the top-quark pair production have been derived. This ratio measurement leads to a cancellation of several systematic effects and allows therefore for a high precision comparison to the theory predictions.

  13. [Comparison of self-reported anthropometric variables and real measurement data].

    Science.gov (United States)

    Díaz-García, J; González-Zapata, L I; Estrada-Restrepo, A

    2012-06-01

    The objectives of this study were to evaluate self-reporting of weight, height, and waist circumference, and to compare that perception with the real measurements in college students of the MESPYN cohort--Medellin, Salud Pública y Nutrición--from the University of Antioquia (UdeA), Colombia. A cross-sectional study was conducted starting with the first measurement of the MESPYN Cohort 2009-2010. The sample included volunteer students from different academic areas. Self-perception of weight, height, and waist circumference were recorded before the real measurements were performed. Intraclass correlation coefficients (ICC) were calculated for all the variables, and an alpha of 0.05 was used. The concordance between real measurements and self-referred values was evaluated with the Bland and Altman method. 424 volunteer students were included. The average real weight (kg) in males was 67.4 +/- 10.4 and self-reported: 67.0 +/- 11.0; in females the real value was 55.7 +/- 10.1 and self-reported: 55.0 +/- 9.0. The average real height (m) in males was 1.73 +/- 6.1 and self-reported: 1.73 +/- 6.0; in females the real value was 1.60 +/- 5.9 and self-reported: 1.61 +/- 6.0. In males, the average real waist circumference (cm) was 76.6 +/- 8.0 and self-reported: 75.0 +/- 14.0; in females the real value was 69.9 +/- 8.0 and self-reported: 70.0 +/- 9.0. Weight ICC: 0.956, 95% CI (0.95; 0.97), (p < 0.01); height ICC: 0.953, 95%IC (0.91; 0.97), (p < 0.01), and waist circumference ICC: 0.593, 95% IC (0.55; 0.65), (p < 0.01). In conclusion, anthropometric nutritional evaluation of UdeA students can be performed with self-reported data for weight and height, but the evaluation of abdominal obesity requires direct measurement of waist circumference.

  14. Rate of self-referencing int he journal Radiologia: An indicator of quality

    International Nuclear Information System (INIS)

    Miguel, A.; Marti-Bonmati, L.

    2000-01-01

    Self-referencing, defined as the number of times articles published in a scientific journal cite previous articles printed in the same journal, is an important indicator of quality. Our purpose was to analyze the rate of self-referencing in the journal Radiologia. All the articles published in Radiologia from 1994 to 1998 were analyzed to determine the index of references to Radiologia (IRR) and the index of articles that refer to Radiologia (IAR). these indices were also calculated for European Radiology (index of references to European Radiologia (IRER) and index or articles referring to European Radiology (IAER), a journal that is listed in the Index Medicus, for the year 1998. Between 1994 and 1998, the IRR ranged from 1.5% to 1,9%. In 1998, it was 1.8% while the IRER was only 0.9%, a difference that was statistically significant (p=0.02). In that same year, the IAR was also higher than the IAER (2.3% versus 1.6%). The rate of self-referencing in Radiologia is higher than that of European Radiology, a journal that is included in the Index Medicus and its Medline database. (Author) 13 refs

  15. Comparing the validity of informant and self-reports of personality using laboratory indices of emotional responding as criterion variables.

    Science.gov (United States)

    Lieberman, Lynne; Liu, Huiting; Huggins, Ashley A; Katz, Andrea C; Zvolensky, Michael J; Shankman, Stewart A

    2016-09-01

    Personality traits relate to risk for psychopathology and can inform predictions about treatment outcome. In an effort to obtain a comprehensive index of personality, informant reports of personality are sometimes obtained in addition to self-reports of personality. However, there is limited research comparing the validity of self- and informant reports of personality, particularly among those with internalizing psychopathology. This is important given that informants may provide an additional (and perhaps different) perspective on individuals' personality. The present study therefore compared how both reports of positive affectivity (PA) and negative affectivity (NA) relate to psychophysiological and subjective measures of emotional responding to positive and negative stimuli. Given that our sample (n = 117) included individuals with no history of psychopathology, as well as individuals with major depressive disorder (MDD) and/or panic disorder (PD), we were also able to explore whether these internalizing diagnoses moderated the association between personality reports and measures of emotional responding. Informant-reported PA predicted physiological responses to positive stimuli (but not negative). Informant-reported NA predicted physiological responses to negative stimuli (but not positive). Self-reported personality did not predict physiological responding, but did predict subjectively measured emotional responding (NA for negative responding, PA for positive responding). Diagnoses of internalizing psychopathology (PD or MDD) did not moderate these associations. Results suggest self- and informant reports of personality may each provide valid indices of an individual's emotional response tendencies, but predict different aspects of those tendencies. © 2016 Society for Psychophysiological Research.

  16. Comparing the Validity of Informant- and Self-reports of Personality Using Laboratory Indices of Emotional Responding as Criterion Variables

    Science.gov (United States)

    Lieberman, Lynne; Liu, Huiting; Huggins, Ashley A.; Katz, Andrea C.; Zvolensky, Michael J.; Shankman, Stewart A.

    2016-01-01

    Personality traits relate to risk for psychopathology and can inform predictions about treatment outcome. In an effort to obtain a comprehensive index of personality, informant-reports of personality are sometimes obtained in addition to self-reports of personality. However, there is limited research comparing the validity of self- and informant-reports of personality, particularly among those with internalizing psychopathology. This is important given that informants may provide an additional (and perhaps different) perspective on individuals’ personality. The present study therefore compared how both reports of positive affectivity (PA) and negative affectivity (NA) relate to psychophysiological and subjective measures of emotional responding to positive and negative stimuli. Given that our sample (n = 117) included individuals with no history of psychopathology, as well as individuals with major depressive disorder (MDD) and/or panic disorder (PD), we were also able to explore whether these internalizing diagnoses moderated the association between personality reports and measures of emotional responding. Informant-reported PA predicted physiological responses to positive stimuli (but not negative). Informant reported NA predicted physiological responses to negative stimuli (but not positive). Self-reported personality did not predict physiological responding, but did predict subjectively measured emotional responding (NA for negative responding; PA for positive responding). Diagnoses of internalizing psychopathology (PD or MDD) did not moderate these associations. Results suggest self- and informant-reports of personality may each provide valid indices of an individual’s emotional response tendencies, but predict different aspects of those tendencies. PMID:27273802

  17. Predicting physical health: implicit mental health measures versus self-report scales.

    Science.gov (United States)

    Cousineau, Tara McKee; Shedler, Jonathan

    2006-06-01

    Researchers have traditionally relied on self-report questionnaires to assess psychological well-being, but such measures may be unable to differentiate individuals who are genuinely psychologically healthy from those who maintain a facade or illusion of mental health based on denial and self-deception. Prior research suggests that clinically derived assessment procedures that assess implicit psychological processes may have advantages over self-report mental health measures. This prospective study compared the Early Memory Index, an implicit measure of mental health/distress, with a range of familiar self-report scales as predictors of physical health. The Early Memory Index showed significant prospective associations with health service utilization and clinically verified illness. In contrast, self-report measures of mental health, perceived stress, life events stress, and mood states did not predict health outcomes. The findings highlight the limitations of self-report questionnaires and suggest that implicit measures have an important role to play in mental health research.

  18. Selective dopamine D3 receptor antagonism by SB-277011A attenuates cocaine reinforcement as assessed by progressive-ratio and variable-cost–variable-payoff fixed-ratio cocaine self-administration in rats

    OpenAIRE

    Xi, Zheng-Xiong; Gilbert, Jeremy G.; Pak, Arlene C.; Ashby, Charles R.; Heidbreder, Christian A.; Gardner, Eliot L.

    2005-01-01

    In rats, acute administration of SB-277011A, a highly selective dopamine (DA) D3 receptor antagonist, blocks cocaine-enhanced brain stimulation reward, cocaine-seeking behaviour and reinstatement of cocaine-seeking behaviour. Here, we investigated whether SB-277011A attenuates cocaine reinforcement as assessed by cocaine self-administration under variable-cost–variable-payoff fixed-ratio (FR) and progressive-ratio (PR) reinforcement schedules. Acute i.p. administration of SB-277011A (3–24 mg/...

  19. Serum IGF-1, IGFBP-3 and their ratio: Potential biochemical growth maturity indicators.

    Science.gov (United States)

    Jain, Nimisha; Tripathi, Tulika; Gupta, S K; Rai, Priyank; Kanase, Anup; Kalra, Shilpa

    2017-12-01

    Determination of skeletal maturation and remaining growth potential is an essential part of treatment planning in orthodontics. The aim of our study was to determine the relationship between IGF-1 levels, IGFBP-3 levels with CVM staging to track the pre pubertal and pubertal growth spurts in female patients in North Indian population. This cross-sectional study was conducted on ninety female subjects in the age group of 8-20 years. Blood samples were collected and centrifuged and serum samples were then analysed by Human IGF-1 and IGFBP-3 enzyme-linked immunosorbent assay kits, specific for IGF-1 and IGFBP-3, respectively. CVM staging on lateral cephalometric radiograph was determined for all patients. Analysis of variance test followed by a post hoc test was used to compare mean IGF-1 and IGFBP-3 corresponding to six stages of cervical vertebrae maturation stages. Linear Pearson's correlations were performed to determine the trends of IGF-1, IGFBP-3, and its ratio relating to CVM stage. The kappa statistic was used to measure inter and intra examiner reliability. P value IGF-1 levels were found to be highest (403.3 ± 12.3 ng/ml) at CVMI3 stage of CVMI. The post-hoc test revealed a significant difference in IGF-1 levels between all stages of CVMI, thereby indicating a specific range of IGF-1 levels for a specific skeletal stage. Mean serum IGFBP-3 levels were found to be highest (5186.8 ± 1384.2 ng/ml) at CVMI4 stage of CVMI. The mean serum IGFBP-3 levels at CVMI4 were found to be significantly higher than the levels at all other CVMI stages except CVMI3 stage. IGF-1 and IGFBP-3 can serve as a potential biochemical indicator for assessment of skeletal maturity.

  20. Anxious and avoidant attachment styles and indicators of recovery in schizophrenia: associations with self-esteem and hope.

    Science.gov (United States)

    Ringer, Jamie M; Buchanan, Erin E; Olesek, Kyle; Lysaker, Paul H

    2014-06-01

    Having an insecure attachment style in schizophrenia has been linked to treatment response and symptom severity in schizophrenia. This study sought to further examine whether attachment style is related to subjective indicators of recovery including hope and self-esteem, independent of symptom level and secondly, whether attachment style in schizophrenia differs from attachment style of persons facing adversity in the form of a prolonged non-psychiatric medical illness. Participants were 52 men with schizophrenia, and 26 with HIV/AIDS who had no history of experiencing severe mental illness. These groups were compared in terms of their endorsement of attachment style. All participants were administered the Experiences in Close Relationships measure of adult attachment style. The schizophrenia group was also given the Rosenberg Self-Esteem Scale to assess self-esteem, the Beck Hopelessness Scale as a measure of hope, and the Positive and Negative Syndrome Scale, as an assessment of symptoms. Avoidant attachment in the schizophrenia group was linked with higher levels of hopelessness while anxious attachment was linked to lower levels of self-esteem. The association between anxious attachment and self-esteem persisted after controlling for severity of positive, negative, and depressive symptoms in a stepwise multiple regression analyses. Compared to the HIV/AIDS group, participants with schizophrenia had significantly higher levels of anxious attachment but not avoidant attachment style. Attachment style may impact attainment of key subjective domains of recovery in schizophrenia such as self-esteem, independent of symptom severity. If self-esteem and/or hopelessness are identified as a focus of treatment, focusing on attachment style may be an important treatment component. Therapist understanding of patients' attachment style may allow for a better understanding of resistance in the therapeutic relationship. Helping persons with schizophrenia to recognize and

  1. Two objective measures of self-esteem.

    Science.gov (United States)

    Lorr, M; Wunderlich, R A

    1986-01-01

    Two scales were constructed to assess self-esteem, conceptualized as reflecting (a) feelings of competence and efficacy, and (b) perceived positive appraisal from significant others. To control for response bias a paired choice format was chosen for the items constructed. A buffer scale designed to measure social assertiveness was also included. Data were collected on three samples of high school boys. The item intercorrelations were subjected to principal component analyses followed by Varimax rotations. In each of the three analyses factors of Confidence, Popularity (Social Approval), and Social Assertiveness emerged. The revised self-esteem scales, each defined by 11 items, have been shown to have acceptable reliability and some concurrent validity based on correlations with the well-known Rosenberg Self-Esteem Scale.

  2. Yearbook sectoral financial ratios in mexico for business benchmarking

    Directory of Open Access Journals (Sweden)

    Deyanira Bernal Domínguez

    2012-05-01

    Full Text Available Financial analysis through ratios is a useful tool for improving organizational performance. Databases of financial information in Mexico are limited, therefore the importance of an annual publication of financial ratios per company and industry average. The objectives of this research are: describe the financial ratios with higher predictive potential and their formulas, as well as the design of a research instrument for measuring the relevance of the publication. A descriptive methodology was applied selecting through the analysis ofempirical studies, several ratios of liquidity, leverage, asset management, business cycle, performance and self-financing. The questionnaire contains 43 reagents to be applied to a statistically representative sample of 46 entrepreneurs in Culiacan, Sinaloa, Mexico.

  3. The Measurement of Fuel-Air Ratio by Analysis for the Oxidized Exhaust Gas

    Science.gov (United States)

    Gerrish, Harold C.; Meem, J. Lawrence, Jr.

    1943-01-01

    An investigation was made to determine a method of measuring fuel-air ratio that could be used for test purposes in flight and for checking conventional equipment in the laboratory. Two single-cylinder test engines equipped with typical commercial engine cylinders were used. The fuel-air ratio of the mixture delivered to the engines was determined by direct measurement of the quantity of air and of fuel supplied and also by analysis of the oxidized exhaust gas and of the normal exhaust gas. Five fuels were used: gasoline that complied with Army-Navy fuel Specification No. AN-VV-F-781 and four mixtures of this gasoline with toluene, benzene, and xylene. The method of determining the fuel-air ratio described in this report involves the measurement of the carbon-dioxide content of the oxidized exhaust gas and the use of graphs for the presented equation. This method is considered useful in aircraft, in the field, or in the laboratory for a range of fuel-air ratios from 0.047 to 0.124.

  4. The Measurement of Fuel-air Ratio by Analysis of the Oxidized Exhaust Gas

    Science.gov (United States)

    Memm, J. Lawrence, Jr.

    1943-01-01

    An investigation was made to determine a method of measuring fuel-air ratio that could be used for test purposes in flight and for checking conventional equipment in the laboratory. Two single-cylinder test engines equipped with typical commercial engine cylinders were used. The fuel-air ratio of the mixture delivered to the engines was determined by direct measurement of the quantity of air and of fuel supplied and also by analysis of the oxidized exhaust gas and of the normal exhaust gas. Five fuels were used: gasoline that complied with Army-Navy Fuel Specification, No. AN-VV-F-781 and four mixtures of this gasoline with toluene, benzene, and xylene. The method of determining the fuel-air ratio described in this report involves the measurement of the carbon-dioxide content of the oxidized exhaust gas and the use of graphs or the presented equation. This method is considered useful in aircraft, in the field, or in the laboratory for a range of fuel-air ratios from 0.047 to 0.124

  5. Surrogate indicators of sensitivity in gynecologic cytology: Can they be used to improve the measurement of sensitivity in the laboratory?

    Directory of Open Access Journals (Sweden)

    Renshaw Andrew

    2009-01-01

    Full Text Available Background: Measuring the sensitivity of screening in gynecologic cytology in real life is problematic. However, other quality measures may correlate with sensitivity, including the atypical squamous cells (ASC/squamous intraepithelial lesion (SIL ratio. Whether these other measures can function as "surrogate indicators" for sensitivity and improve the assessment of sensitivity in the laboratory is not known. Materials and Methods: We compared multiple quality measures with true screening sensitivity in a variety of situations. Results: The abnormal rate, ASC rate, and ASC/SIL ratio were all highly correlated (r = .83 or greater with sensitivity when the overall laboratory sensitivity was low (85% but became less correlated (.64 or less or uncorrelated when the screening sensitivity was higher (88% or 95%, respectively. Sensitivity was more highly correlated with the abnormal rate than the ASC/SIL ratio at low screening sensitivity. While thresholds could be set that were highly sensitive and specific for suboptimal screening, these thresholds were often less than one standard deviation away from the mean. Conclusion: The correlation of the abnormal rate and the ASC/SIL ratio with sensitivity depends on overall sensitivity. Standards to define minimum screening sensitivity can be defined, but these standards are relatively narrow. These features may limit the utility of these quality measures as surrogates for sensitivity.

  6. A comparison of direct versus self-report measures for assessing physical activity in adults: a systematic review

    Directory of Open Access Journals (Sweden)

    Hardt Jill

    2008-11-01

    Full Text Available Abstract Background Accurate assessment is required to assess current and changing physical activity levels, and to evaluate the effectiveness of interventions designed to increase activity levels. This study systematically reviewed the literature to determine the extent of agreement between subjectively (self-report e.g. questionnaire, diary and objectively (directly measured; e.g. accelerometry, doubly labeled water assessed physical activity in adults. Methods Eight electronic databases were searched to identify observational and experimental studies of adult populations. Searching identified 4,463 potential articles. Initial screening found that 293 examined the relationship between self-reported and directly measured physical activity and met the eligibility criteria. Data abstraction was completed for 187 articles, which described comparable data and/or comparisons, while 76 articles lacked comparable data or comparisons, and a further 30 did not meet the review's eligibility requirements. A risk of bias assessment was conducted for all articles from which data was abstracted. Results Correlations between self-report and direct measures were generally low-to-moderate and ranged from -0.71 to 0.96. No clear pattern emerged for the mean differences between self-report and direct measures of physical activity. Trends differed by measure of physical activity employed, level of physical activity measured, and the gender of participants. Results of the risk of bias assessment indicated that 38% of the studies had lower quality scores. Conclusion The findings suggest that the measurement method may have a significant impact on the observed levels of physical activity. Self-report measures of physical activity were both higher and lower than directly measured levels of physical activity, which poses a problem for both reliance on self-report measures and for attempts to correct for self-report – direct measure differences. This review reveals

  7. Measurement of shoulder motion fraction and motion ratio

    International Nuclear Information System (INIS)

    Kang, Yeong Han

    2006-01-01

    This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR (computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was 15 .deg., 19 .deg., 22 .deg. to the cephald for the parallel scapular spine, and the tilting of torso was external oblique 40 .deg., 36 .deg., 22 .deg. for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age (20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, 90 .deg. and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. While the arm elevation was 90 .deg., the shoulder motion fraction was 1.22 (M), 1.70 (W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84 and left was 1.57, 1.32. In right dominant arm (78%), 90 .deg. and Full motion fraction was 1.58, 1.43, in left (22%) 1.82, 1.94. In generation 20, 90 .deg. and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28,60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. The criteria of motion fraction was useful reference for clinical diagnosis the shoulder instability

  8. Artistic creativity of martiros saryan as the indicator of national self ...

    African Journals Online (AJOL)

    Artistic creativity of martiros saryan as the indicator of national self-identification of the personality in a multicultural space: features of methodology of a ... In this article, the life and works of the famous Armenian artist, founder of the modern Armenian school of painting Martiros Saryan (1880-1972) are analyzed in the context ...

  9. Self-guaranteed measurement-based quantum computation

    Science.gov (United States)

    Hayashi, Masahito; Hajdušek, Michal

    2018-05-01

    In order to guarantee the output of a quantum computation, we usually assume that the component devices are trusted. However, when the total computation process is large, it is not easy to guarantee the whole system when we have scaling effects, unexpected noise, or unaccounted for correlations between several subsystems. If we do not trust the measurement basis or the prepared entangled state, we do need to be worried about such uncertainties. To this end, we propose a self-guaranteed protocol for verification of quantum computation under the scheme of measurement-based quantum computation where no prior-trusted devices (measurement basis or entangled state) are needed. The approach we present enables the implementation of verifiable quantum computation using the measurement-based model in the context of a particular instance of delegated quantum computation where the server prepares the initial computational resource and sends it to the client, who drives the computation by single-qubit measurements. Applying self-testing procedures, we are able to verify the initial resource as well as the operation of the quantum devices and hence the computation itself. The overhead of our protocol scales with the size of the initial resource state to the power of 4 times the natural logarithm of the initial state's size.

  10. Energy intensity ratios as net energy measures of United States energy production and expenditures

    International Nuclear Information System (INIS)

    King, C W

    2010-01-01

    In this letter I compare two measures of energy quality, energy return on energy invested (EROI) and energy intensity ratio (EIR) for the fossil fuel consumption and production of the United States. All other characteristics being equal, a fuel or energy system with a higher EROI or EIR is of better quality because more energy is provided to society. I define and calculate the EIR for oil, natural gas, coal, and electricity as measures of the energy intensity (units of energy divided by money) of the energy resource relative to the energy intensity of the overall economy. EIR measures based upon various unit prices for energy (e.g. $/Btu of a barrel of oil) as well as total expenditures on energy supplies (e.g. total dollars spent on petroleum) indicate net energy at different points in the supply chain of the overall energy system. The results indicate that EIR is an easily calculated and effective proxy for EROI for US oil, gas, coal, and electricity. The EIR correlates well with previous EROI calculations, but adds additional information on energy resource quality within the supply chain. Furthermore, the EIR and EROI of oil and gas as well as coal were all in decline for two time periods within the last 40 years, and both time periods preceded economic recessions.

  11. Self-report measures of prospective memory are reliable but not valid.

    Science.gov (United States)

    Uttl, Bob; Kibreab, Mekale

    2011-03-01

    Are self-report measures of prospective memory (ProM) reliable and valid? To examine this question, 240 undergraduate student volunteers completed several widely used self-report measures of ProM including the Prospective Memory Questionnaire (PMQ), the Prospective and Retrospective Memory Questionnaire (PRMQ), the Comprehensive Assessment of Prospective Memory (CAPM) questionnaire, self-reports of retrospective memory (RetM), objective measures of ProM and RetM, and measures of involvement in activities and events, memory strategies and aids use, personality and verbal intelligence. The results showed that both convergent and divergent validity of ProM self-reports are poor, even though we assessed ProM using a newly developed, reliable continuous measure. Further analyses showed that a substantial proportion of variability in ProM self-report scores was due to verbal intelligence, personality (conscientiousness, neuroticism), activities and event involvement (busyness), and use of memory strategies and aids. ProM self-reports have adequate reliability, but poor validity and should not be interpreted as reflecting ProM ability. (PsycINFO Database Record (c) 2011 APA, all rights reserved).

  12. Key indicators for organizational performance measurement

    Directory of Open Access Journals (Sweden)

    Firoozeh Haddadi

    2014-09-01

    Full Text Available Each organization for assessing the amount of utility and desirability of their activities, especially in complex and dynamic environments, requires determining and ranking the vital performance indicators. Indicators provide essential links among strategy, execution and ultimate value creation. The aim of this paper is to develop a framework, which identifies and prioritizes Key Performance Indicators (KPIs that a company should focus on them to define and measure progress towards organizational objectives. For this purpose, an applied research was conducted in 2013 in an Iranian telecommunication company. We first determined the objectives of the company with respect to four perspectives of BSC (Balanced Scorecard framework. Next, performance indicators were listed and paired wise comparisons were accomplished by company's high-ranked employees through standard Analytic Hierarchy Process (AHP questionnaires. This helped us establish the weight of each indicator and to rank them, accordingly.

  13. Measurement of lime/silica ratio in concrete using PGNAA technique

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-12-01

    Prompt gamma neutron activation analysis (PGNAA) technique has been used to determine lime/silica ratio in concrete samples using an accelerator-based PGNAA facility. The ratio was determined from the measured yield of 6.42 MeV prompt {gamma}-rays of calcium and 4.93 MeV {gamma}-rays of silicon from the six concrete samples. The experimental results were compared with the results of the Monte Carlo simulations. An excellent agreement has been achieved between the two. The study has demonstrated successful use of the accelerator-based PGNAA setup in non-destructive analysis of the concrete samples.

  14. Measurement of the Λ→n+γ branching ratio

    International Nuclear Information System (INIS)

    Noble, A.J.; Larson, K.D.; Bassalleck, B.; Fickinger, W.J.; Hall, J.R.; Hallin, A.L.; Hasinoff, M.D.; Horvath, D.; Lowe, J.; McIntyre, E.K.; Measday, D.F.; Miller, J.P.; Roberts, B.L.; Robinson, D.K.; Sakitt, M.; Salomon, M.; Waltham, C.E.; Warner, T.M.; Whitehouse, D.A.; Wolfe, D.M.

    1992-01-01

    The branching ratio for the Λ weak radiative decay has been measured to be B(Λ→n+γ)/(Λ→anything) =[1.78±0.24(stat)± 0.16 0.14 (syst)]x10 -3 . A low-energy kaon beam was used to produce the Λ hyperons via the reaction K - +p→Λ+π 0 at rest. Photons from the signal channel and π 0 decay were detected with a NaI(Tl) array. The final spectrum contains 287 events after background subtraction, an order of magnitude more events than from the only previous measurement

  15. Validation of a dual-isotope plasma ratio method for measurement of cholesterol absorption in rats

    International Nuclear Information System (INIS)

    Zilversmit, D.B.; Hughes, L.B.

    1974-01-01

    Several methods for measuring cholesterol absorption in the rat have been compared. After administration of an oral dose of labeled cholesterol ( 14 C or 3 H) and an intravenous dose of colloidal labeled cholesterol ( 3 H or 14 C) the ratio of the two labels in plasma or whole blood 48 hr or more after dosing compared closely to the ratio of areas under the respective specific activity-time curves. The area ratio method is independent of a time lag between the appearance of oral and intravenous label in the bloodstream. Both measures of cholesterol absorption agree fairly well with a method based on measuring the unabsorbed dietary cholesterol in a pooled fecal sample. The plasma isotope ratio method gave more reproducible results than the fecal collection method when the measurement was repeated in the same animals 5 days after the first measurement. Cholesterol absorption was overestimated by the use of Tween 20-solubilized labeled cholesterol for the intravenous dose. The plasma disappearance curves of injected labeled colloidal cholesterol and cholesterol-labeled chylomicrons infused intravenously over a 3.5-h period in the same animal coincided within experimental error from the first day until 75 days after injection. The plasma isotope ratio method for cholesterol absorption gave the same results in rats practicing coprophagy as in those in which this practice was prevented. The addition of sulfaguanidine to the diet lowered cholesterol absorption as measured by the plasma isotope ratio to the same degree as that measured by the fecal collection method. (U.S.)

  16. Association between the extent of urinary albumin excretion and glycaemic variability indices measured by continuous glucose monitoring.

    Science.gov (United States)

    Jin, S-M; Kim, T-H; Oh, S; Baek, J; Joung, J Y; Park, S-M; Cho, Y Y; Sohn, S Y; Hur, K Y; Lee, M-S; Lee, M-K; Kim, J H

    2015-02-01

    The contribution of glycaemic variability to the microvascular complication of diabetes has not been established. We examined whether there is an independent association between indices of glycaemic variability in continuous glucose monitoring and extent of albuminuria. A total of 173 patients with Type 2 diabetes (without insulin therapy, n = 96; with insulin therapy, n = 77) who had unexplained large fluctuations in blood glucose values underwent three-day continuous glucose monitoring. We used a multinomial logistic regression model to determine whether the indices of glycaemic variability independently affected the odds of having a spot urine albumin/creatinine ratio of 30-299 mg/g and ≥ 300 mg/g. Higher standard deviation (P = 0.002), mean of daily differences (P = 0.023) and mean amplitude of glycaemic excursion (P = 0.043) significantly increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g. In multivariable analysis, only higher standard deviation, but not mean amplitude of glycaemic excursion and mean of daily differences, independently increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g (P = 0.025). Coefficient of variation (sd/mean) was not associated with the odds of having a urine albumin/creatinine ratio of 30-299 or ≥ 300 mg/g. The independent association between standard deviation and the extent of albuminuria was lost when the measures were normalized by mean glucose level. At least in terms of relative measures of glycaemic variability, we failed to demonstrate an independent association between glycaemic variability and albuminuria extent in patients with inadequately controlled Type 2 diabetes. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

  17. Raman scattering method and apparatus for measuring isotope ratios and isotopic abundances

    International Nuclear Information System (INIS)

    Harney, R.C.; Bloom, S.D.

    1978-01-01

    Raman scattering is used to measure isotope ratios and/or isotopic abundances. A beam of quasi-monochromatic photons is directed onto the sample to be analyzed, and the resulting Raman-scattered photons are detected and counted for each isotopic species of interest. These photon counts are treated mathematically to yield the desired isotope ratios or isotopic abundances

  18. Recent self-harm and psychological measures in the emergency department

    Directory of Open Access Journals (Sweden)

    Jason R. Randall

    2014-11-01

    Full Text Available The assessment of self-harm risk is a common, difficult, and perplexing task for many physicians, especially those working in emergency departments (ED. Attempts have been made to determine objective methods for assessing patients with suicidal ideation or self-harm though there is still a lack of knowledge about objective assessments of these patients. A study was conducted where 181 suicidal patients were enrolled in two EDs within the city of Edmonton, Canada. Initial interviews were conducted in the ED which collected basic demographics and medical history as well as psychometric measures including the Beck Hopelessness Scale, Barratt Impulsiveness Scale, Brief Symptom Inventory, Drug Abuse Screening Test 10, and CAGE questionnaire. The results of these measures were compared between those who presented to the ED with self-harm and those who presented only with ideation. Those with recent self-harm scored lower on many of the scales and subscales of distress and impulsivity measured compared to those with no recent self-harm. Possible explanations for this difference include differences in psychological traits between the two groups and possible cathartic effects of self-harm. The lower scores obtained by those that present with self-harm may complicate attempts to use psychometric tools to determine future self-harm risk.

  19. Self-healing concrete by use of microencapsulated bacterial spores

    International Nuclear Information System (INIS)

    Wang, J.Y.; Soens, H.; Verstraete, W.; De Belie, N.

    2014-01-01

    Microcapsules were applied to encapsulate bacterial spores for self-healing concrete. The viability of encapsulated spores and the influence of microcapsules on mortar specimens were investigated first. Breakage of the microcapsules upon cracking was verified by Scanning Electron Microscopy. Self-healing capacity was evaluated by crack healing ratio and the water permeability. The results indicated that the healing ratio in the specimens with bio-microcapsules was higher (48%–80%) than in those without bacteria (18%–50%). The maximum crack width healed in the specimens of the bacteria series was 970 μm, about 4 times that of the non-bacteria series (max 250 μm). The overall water permeability in the bacteria series was about 10 times lower than that in non-bacteria series. Wet–dry cycles were found to stimulate self-healing in mortar specimens with encapsulated bacteria. No self-healing was observed in all specimens stored at 95%RH, indicating that the presence of liquid water is an essential component for self-healing

  20. Self-healing concrete by use of microencapsulated bacterial spores

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.Y. [Magnel Laboratory for Concrete Research, Faculty of Engineering and Architecture, Ghent University, TechnologieparkZwijnaarde 904, B-9052 Ghent (Belgium); Laboratory of Microbial Ecology and Technology (LabMET), Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent (Belgium); Soens, H. [Devan Chemicals NV, Klein Frankrijk 18, 9600 Ronse (Belgium); Verstraete, W. [Laboratory of Microbial Ecology and Technology (LabMET), Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent (Belgium); De Belie, N., E-mail: nele.debelie@ugent.be [Magnel Laboratory for Concrete Research, Faculty of Engineering and Architecture, Ghent University, TechnologieparkZwijnaarde 904, B-9052 Ghent (Belgium)

    2014-02-15

    Microcapsules were applied to encapsulate bacterial spores for self-healing concrete. The viability of encapsulated spores and the influence of microcapsules on mortar specimens were investigated first. Breakage of the microcapsules upon cracking was verified by Scanning Electron Microscopy. Self-healing capacity was evaluated by crack healing ratio and the water permeability. The results indicated that the healing ratio in the specimens with bio-microcapsules was higher (48%–80%) than in those without bacteria (18%–50%). The maximum crack width healed in the specimens of the bacteria series was 970 μm, about 4 times that of the non-bacteria series (max 250 μm). The overall water permeability in the bacteria series was about 10 times lower than that in non-bacteria series. Wet–dry cycles were found to stimulate self-healing in mortar specimens with encapsulated bacteria. No self-healing was observed in all specimens stored at 95%RH, indicating that the presence of liquid water is an essential component for self-healing.

  1. Measurement of the atmospheric muon charge ratio with the OPERA detector

    OpenAIRE

    Mauri, Nicoletta

    2011-01-01

    The atmospheric muon charge ratio, defined as the number of positive over negative charged muons, is an interesting quantity for the study of high energy hadronic interactions in atmosphere and the nature of the primary cosmic rays. The measurement of the charge ratio in the TeV muon energy range allows to study the hadronic interactions in kinematic regions not yet explored at accelerators. The OPERA experiment is a hybrid electronic detector/emulsion apparatus, located in the undergroun...

  2. Iran's Health Reform Plan: Measuring Changes in Equity Indices.

    Science.gov (United States)

    Assari Arani, Abbas; Atashbar, Tohid; Antoun, Joseph; Bossert, Thomas

    2018-03-01

    Two years after the implementation of the Health Sector Evolution Plan (HSEP), this study evaluated the effects of the plan on health equity indices. The main indices assessed by the study were the Out-of-Pocket (OOP) health expenditures, the Fairness in Financial Contribution (FFC) to the health system index, the index of households' Catastrophic Health Expenditure (CHE) and the headcount ratio of Impoverishing Health Expenditure (IHE). The per capita share of costs for total health services has been decreased. The lowered costs have been more felt in rural areas, generally due to sharp decrease in inpatient costs. Per capita pay for outpatient services is almost constant or has slightly increased. The reform plan has managed to improve households' Catastrophic Health Expenditure (CHE) index from an average of 2.9% before the implementation of the plan to 2.3% after the plan. The Fairness in Financial Contribution (FFC) to the health system index has worsened from 0.79 to 0.76, and the headcount ratio of Impoverishing Health Expenditure (IHE) index deteriorated after the implementation of plan from 0.34 to 0.50. Considerable improvement, in decreasing the burden of catastrophic hospital costs in low income strata which is about 26% relative to the time before the implementation of the plan can be regarded as the main achievement of the plan, whereas the worsening in the headcount ratio of IHE and FFC are the equity bottlenecks of the plan.

  3. Reliability and validity of two self-report measures of cognitive flexibility.

    Science.gov (United States)

    Johnco, Carly; Wuthrich, Viviana M; Rapee, Ronald M

    2014-12-01

    Neuropsychological testing currently represents the gold standard in assessing cognitive flexibility. However, this format presents some challenges in terms of time and skills required for administration, scoring, and interpretation. Two self-report measures of cognitive flexibility have been developed to measure aspects of cognitive flexibility in everyday settings, although neither has been validated in an older sample. In this study, we investigated the psychometric properties of 2 self-report measures of cognitive flexibility, the Cognitive Flexibility Inventory (CFI; Dennis & Vander Wal, 2010) and the Cognitive Flexibility Scale (CFS; Martin & Rubin, 1995), against neuropsychological measures of cognitive flexibility in a clinical sample of 47 older adults with comorbid anxiety and depression and a nonclinical sample of 53 community-dwelling older adults. Internal consistency was good for the CFS and CFI in all samples. The clinical sample reported poorer cognitive flexibility than did the nonclinical sample on self-report measures and performed more poorly on some neuropsychological measures. There was evidence of convergent validity between the 2 self-report measures but little relationship between the self-report and neuropsychological measures of cognitive flexibility, suggesting that self-report measures assess a different aspect of cognitive flexibility than does neuropsychological testing. Divergent validity was weak from measures of anxiety and depression in the combined and nonclinical samples but acceptable in the clinical sample. Results suggest that these measures are suitable for use with an older adult sample but do not assess the same aspects of cognitive flexibility as are assessed by neuropsychological assessment. (c) 2014 APA, all rights reserved.

  4. Self-selection of two diet components by Tenebrio molitor (Coleoptera: Tenebrionidae) larvae and its impact on fitness.

    Science.gov (United States)

    Morales-Ramos, J A; Rojas, M G; Shapiro-Ilan, D I; Tedders, W L

    2011-10-01

    We studied the ability of Tenebrio molitor L. (Coleoptera: Tenebrionidae) to self-select optimal ratios of two dietary components to approach nutritional balance and maximum fitness. Relative consumption of wheat bran and dry potato flakes was determined among larvae feeding on four different ratios of these components (10, 20, 30, and 40% potato). Groups of early instars were provided with a measured amount of food and the consumption of each diet component was measured at the end of 4 wk and again 3 wk later. Consumption of diet components by T. molitor larvae deviated significantly from expected ratios indicating nonrandom self-selection. Mean percentages of dry potato consumed were 11.98, 19.16, 19.02, and 19.27% and 11.89, 20.48, 24.67, and 25.97% during the first and second experimental periods for diets with 10, 20, 30, and 40% potato, respectively. Life table analysis was used to determine the fitness of T. molitor developing in the four diet mixtures in a no-choice experiment. The diets were compared among each other and a control diet of wheat bran only. Doubling time was significantly shorter in groups consuming 10 and 20% potato than the control and longer in groups feeding on 30 and 40% potato. The self-selected ratios of the two diet components approached 20% potato, which was the best ratio for development and second best for population growth. Our findings show dietary self-selection behavior in T. molitor larvae, and these findings may lead to new methods for optimizing dietary supplements for T. molitor.

  5. Self-Evaluation of PANDA-FBG Based Sensing System for Dynamic Distributed Strain and Temperature Measurement.

    Science.gov (United States)

    Zhu, Mengshi; Murayama, Hideaki; Wada, Daichi

    2017-10-12

    A novel method is introduced in this work for effectively evaluating the performance of the PANDA type polarization-maintaining fiber Bragg grating (PANDA-FBG) distributed dynamic strain and temperature sensing system. Conventionally, the errors during the measurement are unknown or evaluated by using other sensors such as strain gauge and thermocouples. This will make the sensing system complicated and decrease the efficiency since more than one kind of sensor is applied for the same measurand. In this study, we used the approximately constant ratio of primary errors in strain and temperature measurement and realized the self-evaluation of the sensing system, which can significantly enhance the applicability, as well as the reliability in strategy making.

  6. Isotope ratio measurements of uranium by LA-HR-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Marin, Rafael C.; Sarkis, Jorge E.S., E-mail: rafael.marin@usp.b, E-mail: jesarkis@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    This work describes the utilization of Laser Ablation High Resolution Inductively Mass Spectrometry (LA-HR-ICP-MS) technique for the determination of uranium isotope composition in a UO{sub 2} pellet (CRM -125A) supplied and certified by the New Brunswick Laboratory (NBL). To carry out the adjustments of the parameters was used a glass standard NIST 610, supplied and certified by National Institute of Standards and Technology (NIST). The precision of the measurements were improved by adjusting the following parameters: RF power, laser beam diameter, defocusing of laser beam, laser energy, laser energy-density, auxiliary gas and sample gas. The measurements were performed on a continuous ablation with low energy density and defocusing, which demonstrated to be the optimum to reach the best signal stability. Isotope ratios, {sup 234}U/{sup 238}U, {sup 235}U/{sup 238}U and {sup 236}U/{sup 238}U were measured, reaching relative standard deviations (RSD) from 1.55% to 7.60%. The parameters which caused the greatest impact in order to improve the signal stability were RF power, defocusing and laser beam diameter. The results presented by the measurements revealed that the Laser ablation ICP-MS technique offers a rapid and accurate way to perform uranium isotope ratios without any sample preparation, since it allows carrying out the measurements straight on the sample, besides to preserve the testimony that is very important for safeguards and nuclear forensics purposes. (author)

  7. Readability and comprehension of self-report binge eating measures.

    Science.gov (United States)

    Richards, Lauren K; McHugh, R Kathryn; Pratt, Elizabeth M; Thompson-Brenner, Heather

    2013-04-01

    The validity of self-report binge eating instruments among individuals with limited literacy is uncertain. This study aims to evaluate reading grade level and multiple domains of comprehension of 13 commonly used self-report assessments of binge eating for use in low-literacy populations. We evaluated self-report binge eating measures with respect to reading grade levels, measure length, formatting and linguistic problems. All measures were written at a reading grade level higher than is recommended for patient materials (above the 5th to 6th grade level), and contained several challenging elements related to comprehension. Correlational analyses suggested that readability and comprehension elements were distinct contributors to measure difficulty. Individuals with binge eating who have low levels of educational attainment or limited literacy are often underrepresented in measure validation studies. Validity of measures and accurate assessment of symptoms depend on an individual's ability to read and comprehend instructions and items, and these may be compromised in populations with lower levels of literacy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Evaluation of indices for voltage stability monitoring using PMU measurements

    Directory of Open Access Journals (Sweden)

    Sindy Lorena Ramirez Perdomo

    2014-09-01

    Full Text Available Large disturbances such as voltage collapse and its consequences represent a large challenge to the operational safety of power systems. Therefore, it is important to have indicators of the presence of voltage stability problems in real time. Using phasor measure-ments of voltage and current that are presented in Phasor Measurement Units (PMU, indices for voltage stability monitoring can be calculated in real time. This paper presents some indices for voltage stability monitoring using PMU measurements. Evaluation of such indices on a simplified system was carried out, and the indices were classified according to their method of calculation. Finally, one of these indices was used with the New England 39-bus system under different operating scenarios, including load increments, line output and generator output, to check the indices’ behavior for voltage stability monitoring based on synchronized local measurements.

  9. Mixed carboranethiol self-assembled monolayers on gold surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Yavuz, Adem [Micro and Nanotechnology Department, Graduate School of Natural and Applied Science, Middle East Technical University, Ankara 06800 (Turkey); Sohrabnia, Nima [Department of Chemistry, Middle East Technical University, Ankara 06800 (Turkey); Yilmaz, Ayşen [Micro and Nanotechnology Department, Graduate School of Natural and Applied Science, Middle East Technical University, Ankara 06800 (Turkey); Department of Chemistry, Middle East Technical University, Ankara 06800 (Turkey); Danışman, M. Fatih, E-mail: danisman@metu.edu.tr [Micro and Nanotechnology Department, Graduate School of Natural and Applied Science, Middle East Technical University, Ankara 06800 (Turkey); Department of Chemistry, Middle East Technical University, Ankara 06800 (Turkey)

    2017-08-15

    Highlights: • M1 binds to the gold surface preferentially when co-deposited with M9 or O1. • Contact angles show similar trends regardless of the gold substrate roughness. • Contact angles were lower, with higher hysteresis, on template stripped gold. • Mixed carboranethiol SAMs have similar morphological properties regardless of mixing ratio. - Abstract: Carboranethiol self-assembled monolayers on metal surfaces have been shown to be very convenient systems for surface engineering. Here we have studied pure and mixed self-assembled monolayers (SAMs) of three different carboranethiol (CT) isomers on gold surfaces. The isomers were chosen with dipole moments pointing parallel to (m-1-carboranethiol, M1), out of (m-9-carboranethiol, M9) and into (o-1-carboranethiol, O1) the surface plane, in order to investigate the effect of dipole moment orientation on the film properties. In addition, influence of the substrate surface morphology on the film properties was also studied by using flame annealed (FA) and template stripped (TS) gold surfaces. Contact angle measurements indicate that in M1/M9 and M1/O1 mixed SAMs, M1 is the dominant species on the surface even for low M1 ratio in the growth solution. Whereas for O1/M9 mixed SAMs no clear evidence could be observed indicating dominance of one of the species over the other one. Though contact angle values were lower and hysteresis values were higher for SAMs grown on TS gold surfaces, the trends in the behavior of the contact angles with changing mixing ratio were identical for SAMs grown on both substrates. Atomic force microscopy images of the SAMs on TS gold surfaces indicate that the films have similar morphological properties regardless of mixing ratio.

  10. Business process performance measurement: a structured literature review of indicators, measures and metrics.

    Science.gov (United States)

    Van Looy, Amy; Shafagatova, Aygun

    2016-01-01

    Measuring the performance of business processes has become a central issue in both academia and business, since organizations are challenged to achieve effective and efficient results. Applying performance measurement models to this purpose ensures alignment with a business strategy, which implies that the choice of performance indicators is organization-dependent. Nonetheless, such measurement models generally suffer from a lack of guidance regarding the performance indicators that exist and how they can be concretized in practice. To fill this gap, we conducted a structured literature review to find patterns or trends in the research on business process performance measurement. The study also documents an extended list of 140 process-related performance indicators in a systematic manner by further categorizing them into 11 performance perspectives in order to gain a holistic view. Managers and scholars can consult the provided list to choose the indicators that are of interest to them, considering each perspective. The structured literature review concludes with avenues for further research.

  11. An investigation of outcome expectancies as a predictor of treatment response for combat veterans with PTSD: comparison of clinician, self-report, and biological measures.

    Science.gov (United States)

    Price, Matthew; Maples, Jessica L; Jovanovic, Tanja; Norrholm, Seth D; Heekin, Mary; Rothbaum, Barbara O

    2015-06-01

    Outcome expectancy, or the degree to which a client believes that therapy will result in improvement, is related to improved treatment outcomes for multiple disorders. There is a paucity of research investigating this relation in regards to posttraumatic stress disorder (PTSD). Additionally, the bulk of the research on outcome expectancy and treatment outcomes has relied mostly on self-report outcome measures. The relation between outcome expectancy on self-report measures, clinician-rated measures, and two biological indices (fear-potentiated startle and cortisol reactivity) of PTSD symptoms was explored. The sample included combat veterans (N = 116) treated with virtual reality exposure therapy for PTSD. Results supported a negative association between outcome expectancy and both self-report and clinician-rated symptoms at the conclusion of treatment, but outcome expectancy was related to the magnitude of change during treatment for self-report measures only. Outcome expectancy was unrelated to biological measures of treatment response. These findings suggest that outcome expectancy may be related to patient and clinician perceptions of outcomes, but not biological indices of outcome for PTSD. © 2015 Wiley Periodicals, Inc.

  12. Effects of crystalline grain size and packing ratio of self-forming core/shell nanoparticles on magnetic properties at up to GHz bands

    International Nuclear Information System (INIS)

    Suetsuna, Tomohiro; Suenaga, Seiichi; Sakurada, Shinya; Harada, Koichi; Tomimatsu, Maki; Takahashi, Toshihide

    2011-01-01

    Self-forming core/shell nanoparticles of magnetic metal/oxide with crystalline grain size of less than 40 nm were synthesized. The nanoparticles were highly concentrated in an insulating matrix to fabricate a nanocomposite, whose magnetic properties were investigated. The crystalline grain size of the nanoparticles strongly influenced the magnetic anisotropy field, magnetic coercivity, relative permeability, and loss factor (tan δ=μ''/μ') at high frequency. The packing ratio of the magnetic metallic phase in the nanocomposite also influenced those properties. High permeability with low tan δ of less than 1.5% at up to 1 GHz was obtained in the case of the nanoparticles with crystalline grain size of around 15 nm with large packing ratio of the nanoparticles. - Research highlights: → Self-forming core/shell nanoparticles of magnetic metal/oxide were synthesized. → Crystalline grain size of the nanoparticle and its packing ratio were controlled. → Magnetic properties changed according to the size and packing ratio.

  13. Measuring emergency department nurses' attitudes towards deliberate self-harm using the Self-Harm Antipathy Scale.

    LENUS (Irish Health Repository)

    Conlon, Mary

    2012-01-31

    The emergency department is an important gateway for the treatment of self-harm patients. Nurses\\' attitudes towards patients who self-harm can be negative and often nurses experience frustration, helplessness, ambivalence and antipathy. Patients are often dissatisfied with the care provided, and meeting with positive or negative attitudes greatly influences whether they seek additional help. A quantitative design was utilised to measure emergency department nurses\\' attitudes towards deliberate self-harm. The \\'Self-Harm Antipathy Scale\\

  14. Discrepancy between self-assessed hearing status and measured audiometric evaluation.

    Directory of Open Access Journals (Sweden)

    So Young Kim

    Full Text Available The purpose of this study was to examine the difference between self-reported hearing status and hearing impairment assessed using conventional audiometry. The associated factors were examined when a concordance between self-reported hearing and audiometric measures was lacking.In total, 19,642 individuals ≥20 years of age who participated in the Korea National Health and Nutrition Examination Surveys conducted from 2009 through 2012 were enrolled. Pure-tone hearing threshold audiometry (PTA was measured and classified into three levels: <25 dB (normal hearing; ≥25 dB <40 dB (mild hearing impairment; and ≥40 dB (moderate-to-severe hearing impairment. The self-reported hearing loss was categorized into 3 categories. The participants were categorized into three groups: the concordance (matched between self-reported hearing loss and audiometric PTA, overestimation (higher self-reported hearing loss compared to audiometric PTA, and underestimation groups (lower self-reported hearing loss compared to audiometric PTA. The associations of age, sex, education level, stress level, anxiety/depression, tympanic membrane (TM status, hearing aid use, and tinnitus with the discrepancy between the hearing self-reported hearing loss and audiometric pure tone threshold results were analyzed using multinomial logistic regression analysis with complex sampling.Overall, 80.1%, 7.1%, and 12.8% of the participants were assigned to the concordance, overestimation, and underestimation groups, respectively. Older age (adjusted odds ratios [AORs] = 1.28 [95% confidence interval = 1.19-1.37] and 2.80 [2.62-2.99] for the overestimation and the underestimation groups, respectively, abnormal TM (2.17 [1.46-3.23] and 1.59 [1.17-2.15], and tinnitus (2.44 [2.10-2.83] and 1.61 [1.38-1.87] were positively correlated with both the overestimation and underestimation groups. Compared with specialized workers, service workers, manual workers, and the unemployed were more likely

  15. ROLE AND IMPORTANCE OF KEY PERFORMANCE INDICATORS MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Rade Stanković

    2011-03-01

    Full Text Available Key performance indicators are financial and non financial indicators that organizations use inorder to estimate and fortify how successful they are, aiming previously established long lastinggoals. Appropriate selection of indicators that will be used for measuring is of a greatest importance.Process organization of business is necessary to be constitute in order to realize such effective andefficient system or performance measuring via KPI. Process organization also implies customerorientation and necessary flexibility in nowadays condition of global competition.Explanation of process organization, the way of KPI selection, and practical example of KPImeasuring in Toyota dealerships are presented in this paper.

  16. Electrophysiological indices of response inhibition in a Go/NoGo task predict self-control in a social context.

    Directory of Open Access Journals (Sweden)

    Kyle Nash

    Full Text Available Recent research demonstrates that response inhibition-a core executive function-may subserve self-regulation and self-control. However, it is unclear whether response inhibition also predicts self-control in the multifaceted, high-level phenomena of social decision-making. Here we examined whether electrophysiological indices of response inhibition would predict self-control in a social context. Electroencephalography was recorded as participants completed a widely used Go/NoGo task (the cued Continuous Performance Test. Participants then interacted with a partner in an economic exchange game that requires self-control. Results demonstrated that greater NoGo-Anteriorization and larger NoGo-P300 peak amplitudes-two established electrophysiological indices of response inhibition-both predicted more self-control in this social game. These findings support continued integration of executive function and self-regulation and help extend prior research into social decision-making processes.

  17. A Meta-Analysis of the Convergent Validity of Self-Control Measures

    Science.gov (United States)

    Duckworth, Angela Lee; Kern, Margaret L.

    2011-01-01

    There is extraordinary diversity in how the construct of self-control is operationalized in research studies. We meta-analytically examined evidence of convergent validity among executive function, delay of gratification, and self- and informant-report questionnaire measures of self-control. Overall, measures demonstrated moderate convergence (rrandom = .27 [95% CI = .24, .30]; rfixed = .34 [.33, .35], k = 282 samples, N = 33,564 participants), although there was substantial heterogeneity in the observed correlations. Correlations within and across types of self-control measures were strongest for informant-report questionnaires and weakest for executive function tasks. Questionnaires assessing sensation seeking impulses could be distinguished from questionnaires assessing processes of impulse regulation. We conclude that self-control is a coherent but multidimensional construct best assessed using multiple methods. PMID:21643479

  18. Indicators System for Poverty Measurement

    Directory of Open Access Journals (Sweden)

    Constantin Mitrut

    2006-10-01

    Full Text Available Poverty represents a life aspect which is focusing the attention of both the macroeconomic analysis and the international comparisons. In order to measure the level being recorded by this phenomenon, there is a system of indicators which are used in order to underline, in a correlated manner, a number of aspects which are characterizing, quality and quantity wise, the evolution of the poverty in a specific country or, to a larger extent, through comparative surveys, at international level. Despite the fact that they are not the only instrument being used within the process of comparison of the stages of social and economic development at the international level, however the poverty indicators are providing a clear significance to the worked out surveys. In fact, the very purpose of the economic activity consists of increasing welfare and, as much as possible, at least reducing, if not eradicating, the poverty. The present work is broadly presenting the methodology as well as, both theoretical and practical, the way of computing the poverty, making a synthesis of the specific used indicators.

  19. Peptide self-association in aqueous trifluoroethanol monitored by pulsed field gradient NMR diffusion measurements

    Energy Technology Data Exchange (ETDEWEB)

    Yao Shenggen [Biomolecular Research Institute (Australia); Howlett, Geoffrey J. [University of Melbourne, Department of Biochemistry and Molecular Biology (Australia); Norton, Raymond S. [Biomolecular Research Institute (Australia)

    2000-02-15

    Defining the self-association state of a molecule in solution can be an important step in NMR-based structure determination. This is particularly true of peptides, where there can be a relatively small number of long-range interactions and misinterpretation of an intermolecular NOE as an intramolecular contact can have a dramatic influence on the final calculated structure. In this paper, we have investigated the use of translational self-diffusion coefficient measurements to detect self-association in aqueous trifluoroethanol of three peptides which are analogues of the C-terminal region of human neuropeptide Y. Experimentally measured diffusion coefficients were extrapolated to D{sup 0}, the limiting value as the peptide concentration approaches zero, and then converted to D{sub 20,w}, the diffusion coefficient after correction for temperature and the viscosity of the solvent. A decrease in D{sub 20,w} of about 16% was found for all three peptides in aqueous TFE (30% by volume) compared with water, which is in reasonable agreement with the expected decrease upon dimerisation, the presence of which was indicated by sedimentation equilibrium measurements. Apparent molecular masses of these peptides in both solutions were also calculated from their diffusion coefficients and similar results were obtained. Several potential internal standards, including acetone, acetonitrile, dimethylsulfoxide and dioxane, were assessed as monitors of solution viscosity over a range of trifluoroethanol concentrations. Compared with independent measurements of viscosity, acetonitrile was the most accurate standard among these four. The practical limitations of a quantitative assessment of peptide self-association from translational diffusion coefficients measured by PFGNMR, including the calculation of apparent molecular mass, are also discussed.

  20. Academic Self-Concept: Modeling and Measuring for Science

    Science.gov (United States)

    Hardy, Graham

    2014-01-01

    In this study, the author developed a model to describe academic self-concept (ASC) in science and validated an instrument for its measurement. Unlike previous models of science ASC, which envisage science as a homogenous single global construct, this model took a multidimensional view by conceiving science self-concept as possessing distinctive…

  1. NO{sub x} emission indices of subsonic wide-bodied jet aircraft at cruise altitude: In situ measurements and predictions

    Energy Technology Data Exchange (ETDEWEB)

    Schulte, P.; Schlager, H.; Schumann, U. [Deutsche Forschungsanstalt fuer Luft- und Raumfahrt e.V. (DLR), Wessling (Germany). Inst. fuer Physik der Atmosphaere; Baughcum, S.L. [Boeing Co., Seattle, WA (United States); Deidewig, F. [Deutsche Forschungsanstalt fuer Luft- und Raumfahrt e.V. (DLR), Koeln (Germany). Inst. fuer Antriebstechnik

    1996-10-01

    In situ measurements of NO, NO{sub 2}, and CO{sub 2} volume mixing ratios have been carried out in the near field exhaust plumes of seven subsonic wide-bodied jet aircraft using the DLR research aircraft `Falcon`. For three additional aircraft only NO and CO{sub 2} was measured. Plume ages of 50 s to 150 s have been covered, with maximum observed exhaust gas enhancements of 319 ppbv and 51 ppmv for {Delta}[NO{sub x}] and {Delta}[CO{sub 2}], respectively, relative to ambient values. These measurements are used to derive NO{sub x} emission indices for seven of the individual aircraft/engine combinations. The NO{sub x} emission indices derived range from 12.3 g/kg to 30.4 g/kg. They are compared with predicted emission index values, calculated for the same aircraft engine and the actual conditions using two newly developed fuel flow correlation methods. The calculated emission indices were mostly within or close to the error limits of the measured values. On average, the predictions from both methods were 12% lower than the measured values, with an observed maximum deviation of 25%. The ratio {gamma}=[NO{sub 2}]/[NO{sub x}] found during the present measurements ranged from 0.06 to 0.11 for five daytime cases and was around 0.22 for two nighttime cases. By use of a simple box model of the plume chemistry and dilution these data were used to estimate the initial value {gamma}{sub 0} present at the engine exit plane. {gamma}{sub 0} values between 0 and 0.15 were found. These where applied to estimate the corresponding NO{sub 2} for the three cases where only NO was measured. (orig.)

  2. Measuring autobiographical fluency in the self-memory system.

    Science.gov (United States)

    Rathbone, Clare J; Moulin, Chris J A

    2014-01-01

    Autobiographical memory is widely considered to be fundamentally related to concepts of self and identity. However, few studies have sought to test models of self and memory directly using experimental designs. Using a novel autobiographical fluency paradigm, the present study investigated memory accessibility for different levels of self-related knowledge. Forty participants generated 20 "I am" statements about themselves, from which the 1st, 5th, 10th, 15th, and 20th were used as cues in a two-minute autobiographical fluency task. The most salient aspects of the self, measured by both serial position and ratings of personal significance, were associated with more accessible sets of autobiographical memories. This finding supports theories that view the self as a powerful organizational structure in memory. Results are discussed with reference to models of self and memory.

  3. The Use of a Pressure-Indicating Sensor Film to Provide Feedback upon Hydrogel-Forming Microneedle Array Self-Application In Vivo.

    Science.gov (United States)

    Vicente-Pérez, Eva M; Quinn, Helen L; McAlister, Emma; O'Neill, Shannon; Hanna, Lezley-Anne; Barry, Johanne G; Donnelly, Ryan F

    2016-12-01

    To evaluate the combination of a pressure-indicating sensor film with hydrogel-forming microneedle arrays, as a method of feedback to confirm MN insertion in vivo. Pilot in vitro insertion studies were conducted using a Texture Analyser to insert MN arrays, coupled with a pressure-indicating sensor film, at varying forces into excised neonatal porcine skin. In vivo studies involved twenty human volunteers, who self-applied two hydrogel-forming MN arrays, one with a pressure-indicating sensor film incorporated and one without. Optical coherence tomography was employed to measure the resulting penetration depth and colorimetric analysis to investigate the associated colour change of the pressure-indicating sensor film. Microneedle insertion was achieved in vitro at three different forces, demonstrating the colour change of the pressure-indicating sensor film upon application of increasing pressure. When self-applied in vivo, there was no significant difference in the microneedle penetration depth resulting from each type of array, with a mean depth of 237 μm recorded. When the pressure-indicating sensor film was present, a colour change occurred upon each application, providing evidence of insertion. For the first time, this study shows how the incorporation of a simple, low-cost pressure-indicating sensor film can indicate microneedle insertion in vitro and in vivo, providing visual feedback to assure the user of correct application. Such a strategy may enhance usability of a microneedle device and, hence, assist in the future translation of the technology to widespread clinical use.

  4. First measurement of the Omega /sup -/ decay branching ratios

    CERN Document Server

    Bourquin, M; Chatelus, Y; Chollet, J C; Degré, A; Froidevaux, D; Fyfe, A R; Gaillard, J M; Gee, C N P; Gibson, W M; Igo-Kemenes, P; Jeffreys, P W; Merkel, B; Morand, R; Plothow, H; Repellin, J P; Saunders, B J; Sauvage, G; Schiby, B; Siebert, H W; Smith, V J; Streit, K P; Strub, R; Thresher, J J; Tovey, Stuart N

    1979-01-01

    In an experiment in the CERN-SPS charged-hyperon beam, the main Omega /sup -/ decay branching ratios have been measured to be Gamma ( Omega /sup -/ to Lambda K/sup -/)/ Gamma (all)=0.686+or-0.013, Gamma ( Omega /sup -/ to Xi /sup 0/ pi /sup -/)/ Gamma (all) =0.234+or-0.013, Gamma ( Omega /sup -/ to Xi /sup -/ pi /sup 0/)/ Gamma (all)=0.080+or-0.008. The relative branching ratio of the two Xi pi modes provides a test of the Delta I=1/2 rule in decuplet-octet transitions. A search has also been made for the rare decay modes Omega /sup -/ to Lambda pi /sup -/, Omega /sup -/ to Xi /sup -/ gamma , Omega /sup -/ to Xi /sup -/ pi /sup +/ pi /sup -/ and Omega /sup -/ to Xi /sup 0/e/sup -/ nu . (6 refs).

  5. Measurement of transparency ratios for protons from short-range correlated pairs

    Science.gov (United States)

    Hen, O.; Hakobyan, H.; Shneor, R.; Piasetzky, E.; Weinstein, L. B.; Brooks, W. K.; May-Tal Beck, S.; Gilad, S.; Korover, I.; Beck, A.; Adhikari, K. P.; Aghasyan, M.; Amaryan, M. J.; Anefalos Pereira, S.; Arrington, J. R.; Baghdasaryan, H.; Ball, J.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Bono, J.; Boiarinov, S.; Briscoe, W. J.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Dodge, G. E.; Doughty, D.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fleming, J. A.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guo, L.; Hafidi, K.; Harrison, N.; Heddle, D.; Hicks, K.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jo, H. S.; Joo, K.; Keller, D.; Khandaker, M.; Khetarpal, P.; Kim, A.; Klein, F. J.; Koirala, S.; Kubarovsky, A.; Kubarovsky, V.; Kuhn, S. E.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Martinez, D.; Mayer, M.; McKinnon, B.; Mineeva, T.; Mokeev, V.; Montgomery, R. A.; Moutarde, H.; Munevar, E.; Munoz Camacho, C.; Mustapha, B.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Pappalardo, L. L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Phelps, E.; Phillips, J. J.; Pisano, S.; Pivnyuk, N.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Puckett, A. J. R.; Raue, B. A.; Rimal, D.; Ripani, M.; Ritchie, B. G.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tian, Ye; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Vlassov, A.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zheng, X.; Zonta, I.

    2013-05-01

    Nuclear transparency, Tp (A), is a measure of the average probability for a struck proton to escape the nucleus without significant re-interaction. Previously, nuclear transparencies were extracted for quasi-elastic A (e ,e‧ p) knockout of protons with momentum below the Fermi momentum, where the spectral functions are well known. In this Letter we extract a novel observable, the transparency ratio, Tp (A) /Tp(12 C), for knockout of high-missing-momentum protons from the breakup of short-range correlated pairs (2N-SRC) in Al, Fe and Pb nuclei relative to C. The ratios were measured at momentum transfer Q2 ⩾ 1.5(GeV /c) 2 and xB ⩾ 1.2 where the reaction is expected to be dominated by electron scattering from 2N-SRC. The transparency ratios of the knocked-out protons coming from 2N-SRC breakup are 20-30% lower than those of previous results for low missing momentum. They agree with Glauber calculations and agree with renormalization of the previously published transparencies as proposed by recent theoretical investigations. The new transparencies scale as A - 1 / 3, which is consistent with dominance of scattering from nucleons at the nuclear surface.

  6. The properties of self-report research measures: beyond psychometrics.

    Science.gov (United States)

    Blount, Claire; Evans, Chris; Birch, Sarah; Warren, Fiona; Norton, Kingsley

    2002-06-01

    Self-report measures pertinent for personality disorder are widely used and many are available. Their relative merits are usually assessed on nomothetic psychometrics and acceptability to users is neglected. We report reactions of lay, patient and professional groups to the Personality Diagnostic Questionnaire (PDQ-IV); Millon Clinical Multiaxial Inventory (MCMI-III); the Borderline Syndrome Index (BSI); Rosenberg's Self-Esteem Scale (RSE) and the Social Functioning Questionnaire (SFQ). These were sent to 148 professionals, ex-patients and lay people for comment. Thirty-six per cent were returned. Pattern-coding by three raters revealed problematic themes across all measures, including inappropriate length, vague items and language, cultural assumptions and slang, state-bias and response-set. Measures can be depressing and upsetting for some participants (both patients and non-patients), hence administration of measures should be sensitive. Treatment may make people more self-aware, which may compromise validity for outcome research. This evaluation raises issues and concerns, which are missed in traditional psychometric evaluation.

  7. High-precision branching ratio measurement for the superallowed β+ emitter 62Ga

    International Nuclear Information System (INIS)

    Finlay, P.E.J.

    2007-01-01

    A high-precision branching ratio measurement for the superallowed β + decay of 62 Ga was performed at the Isotope Separator and Accelerator radioactive ion beam facility. An array of 20 high-purity germanium detectors known as the 8π spectrometer was employed to detect the rays emitted following the Gamow-Teller and non-analog Fermi decays of 62 Ga, while the plastic scintillator array known as SCEPTAR was used to detect the emitted particles. A total of 32 γ rays were identified, establishing the superallowed branching ratio to be 99:859(8)%. Combined with the most recent half-life and Q-value measurements for 62 Ga, this branching ratio yields an ft-value of 3074.3 ± 1.1 s. Comparisons between the superallowed ft-value determined in this work and the world average Ft-bar are made, providing a benchmark for the refinement of theoretical models used to describe isospin-symmetry breaking in A ≥ 62 nuclei. (author)

  8. Indices to measure risk of HIV acquisition in Rakai, Uganda.

    Directory of Open Access Journals (Sweden)

    Joseph Kagaayi

    Full Text Available INTRODUCTION: Targeting most-at-risk individuals with HIV preventive interventions is cost-effective. We developed gender-specific indices to measure risk of HIV among sexually active individuals in Rakai, Uganda. METHODS: We used multivariable Cox proportional hazards models to estimate time-to-HIV infection associated with candidate predictors. Reduced models were determined using backward selection procedures with Akaike's information criterion (AIC as the stopping rule. Model discrimination was determined using Harrell's concordance index (c index. Model calibration was determined graphically. Nomograms were used to present the final prediction models. RESULTS: We used samples of 7,497 women and 5,783 men. 342 new infections occurred among females (incidence 1.11/100 person years, and 225 among the males (incidence 1.00/100 person years. The final model for men included age, education, circumcision status, number of sexual partners, genital ulcer disease symptoms, alcohol use before sex, partner in high risk employment, community type, being unaware of a partner's HIV status and community HIV prevalence. The Model's optimism-corrected c index was 69.1 percent (95% CI = 0.66, 0.73. The final women's model included age, marital status, education, number of sex partners, new sex partner, alcohol consumption by self or partner before sex, concurrent sexual partners, being employed in a high-risk occupation, having genital ulcer disease symptoms, community HIV prevalence, and perceiving oneself or partner to be exposed to HIV. The models optimism-corrected c index was 0.67 (95% CI = 0.64, 0.70. Both models were well calibrated. CONCLUSION: These indices were discriminative and well calibrated. This provides proof-of-concept that population-based HIV risk indices can be developed. Further research to validate these indices for other populations is needed.

  9. Is floral structure a reliable indicator of breeding system in the Brassicaceae?

    Directory of Open Access Journals (Sweden)

    Phillip A Salisbury

    Full Text Available This study investigated the usefulness of floral characters as a potential indicator of breeding system in the Brassicaceae. Initially, pod set, seed set and pollen tube growth experiments were carried out to confirm the breeding systems of 53 lines representing 25 different cultivated and weedy species from the Brassicaceae. The results of the pod set tests clearly differentiated between self-compatible and self-incompatible species. Floral characters were then evaluated on one or more lines of each of the 25 species. Fourteen floral characters were evaluated including, flower diameter, Cruden's outcrossing index, timing and direction of dehiscence and pollen-ovule ratio. Significant differences between species were evident in all of the floral characteristics evaluated. Flower diameter was generally larger in self-incompatible species than self-compatible species and pollen/ovule ratio was generally higher in self-incompatible species than self-compatible species. However, none of the floral characteristics was able to clearly differentiate the self-compatible and self-incompatible species and allow prediction of the breeding system with absolute confidence. The floral characteristic which was most effective at differentiating the two groups was anther direction at dehiscence.

  10. Relative contributions of self-efficacy, self-regulation, and self-handicapping in predicting student procrastination.

    Science.gov (United States)

    Strunk, Kamden K; Steele, Misty R

    2011-12-01

    The relative contributions of self-efficacy, self-regulation, and self-handicapping student procrastination were explored. College undergraduate participants (N = 138; 40 men, 97 women, one not reporting sex) filled out the Procrastination Scale, the Self-Handicapping Scale-Short Form, and the Self-regulation and Self-handicapping scales of the Motivated Strategies for Learning Questionnaire. A hierarchical regression of the above measures indicated that self-efficacy, self-regulation, and self-handicapping all predicted scores on the Procrastination Scale, but self-regulation fully accounted for the predictive power of self-efficacy. The results suggested self-regulation and self-handicapping predict procrastination independently. These findings are discussed in relation to the literature on the concept of "self-efficacy for self-regulation" and its use in the field of procrastination research.

  11. Consistency between Self-Reported and Recorded Values for Clinical Measures

    OpenAIRE

    III, Joseph Thomas; Paulet, Mindy; Rajpura, Jigar R.

    2016-01-01

    Objectives. This study evaluated consistency between self-reported values for clinical measures and recorded clinical measures. Methods. Self-reported values were collected for the clinical measures: systolic blood pressure, diastolic blood pressure, glucose level, height, weight, and cholesterol from health risk assessments completed by enrollees in a privately insured cohort. Body mass index (BMI) was computed from reported height and weight. Practitioner recorded values for the clinical me...

  12. Measuring the differences in work ratios between pediatric and adult ophthalmologic examinations.

    Science.gov (United States)

    Hyun, Joo; Chang, Jee Ho; Kim, Seung Hoon; Park, Song Hee; Kim, Sunghoon

    2017-06-01

    To assess the differences in work needed for pediatric and adult ophthalmologic examinations. Seven ophthalmology residents conducted slit-lamp and refraction examinations on children 3-7 years of age and adults 20-69 years of age. The examiners reported the magnitude estimate (ME) of their work in relation to two references (cross-reference ME): average adult examination and average pediatric examination. The examination time was also measured. For the slit-lamp examination, 50 children and 58 adults were recruited. The ME was 1.45 (95% CI, 1.30-1.62) times higher for the pediatric examinations than for the adult examinations when the reference was an average adult case. With respect to time, the pediatric examinations took 1.22 (95% CI, 1.06-1.41) times longer than the adult examinations. For the refraction examinations, 58 children and 96 adults were recruited. The ME was 1.35 (95% CI, 1.21-1.52) times higher for the pediatric examinations. The pediatric examination took 1.32 (95% CI, 1.16-1.50) times longer than the adult examination. The cross-reference ME ratios measuring the pediatric over adult examinations against both the pediatric and adult reference cases were equivalent in both the slit-lamp and the refraction examinations; however, the ME and time ratios of the pediatric over the adult examinations were not equivalent for the slit-lamp or for the refraction examinations. The cross-reference ME showed that pediatric ophthalmologic examinations require more work than the adult examination with validity and reliability. The time estimate was insufficient as a single indicator for work estimation. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  13. Technical note: Using distributed temperature sensing for Bowen ratio evaporation measurements

    Science.gov (United States)

    Schilperoort, Bart; Coenders-Gerrits, Miriam; Luxemburg, Willem; Jiménez Rodríguez, César; Cisneros Vaca, César; Savenije, Hubert

    2018-01-01

    Rapid improvements in the precision and spatial resolution of distributed temperature sensing (DTS) technology now allow its use in hydrological and atmospheric sciences. Introduced by ) is the use of DTS for measuring the Bowen ratio (BR-DTS), to estimate the sensible and latent heat flux. The Bowen ratio is derived from DTS-measured vertical profiles of the air temperature and wet-bulb temperature. However, in previous research the measured temperatures were not validated, and the cables were not shielded from solar radiation. Additionally, the BR-DTS method has not been tested above a forest before, where temperature gradients are small and energy storage in the air column becomes important. In this paper the accuracy of the wet-bulb and air temperature measurements of the DTS are verified, and the resulting Bowen ratio and heat fluxes are compared to eddy covariance data. The performance of BR-DTS was tested on a 46 m high tower in a mixed forest in the centre of the Netherlands in August 2016. The average tree height is 26 to 30 m, and the temperatures are measured below, in, and above the canopy. Using the vertical temperature profiles the storage of latent and sensible heat in the air column was calculated. We found a significant effect of solar radiation on the temperature measurements, leading to a deviation of up to 3 K. By installing screens, the error caused by sunlight is reduced to under 1 K. Wind speed seems to have a minimal effect on the measured wet-bulb temperature, both below and above the canopy. After a simple quality control, the Bowen ratio measured by DTS correlates well with eddy covariance (EC) estimates (r2 = 0.59). The average energy balance closure between BR-DTS and EC is good, with a mean underestimation of 3.4 W m-2 by the BR-DTS method. However, during daytime the BR-DTS method overestimates the available energy, and during night-time the BR-DTS method estimates the available energy to be more negative. This difference could be

  14. Concordance between self-reported pre-pregnancy body mass index (BMI) and BMI measured at the first prenatal study contact.

    Science.gov (United States)

    Natamba, Barnabas K; Sanchez, Sixto E; Gelaye, Bizu; Williams, Michelle A

    2016-07-26

    The 2009 Institute of Medicine (IOM) gestational weight recommendations are tailored to women's pre-pregnancy body mass index (BMI). Limited evidence exists on methods for estimating women's pre-pregnancy BMI, particularly for women living in low and middle income countries. Using data from collected among Peruvian pregnant women, we compared the concordance between self-reported pre-pregnancy BMI with BMI measured at the earliest prenatal study visit. Data were from the Pregnancy Outcomes Maternal and Infant Study (PrOMIS), a cohort of pregnant women at the Instituto Nacional Materno Perinatal (INMP) in Lima, Peru. 2605 women aged 18 to 49 years (mean ± SD gestational age = 10.9 ± 3.3 weeks) were included in the study. Self-reported pre-pregnancy weight and height and measured weight and height were collected at the first prenatal study contact. We assessed the concordance between measured and self-reported BMI; and, the agreement among indicators of nutritional status obtained using measured and self-reported BMI. On average, weight measured at the first prenatal study visit was 0.27 kg higher than self-reported pre-pregnancy weight (p overweight or obese BMI categories tended to be lower when using self-reported BMI (38.2 %) than when using measured BMI (47.7 %). Self-reported pre-pregnancy BMI was strongly correlated with BMI measured at the first prenatal study contact. The findings potentially suggest that, in this context, there is minimal change between pre-pregnancy BMI and BMI measured at the first prenatal study contact; or, that women in this study just recalled their most recent measured anthropometrics (including values obtained during the index pregnancy but before enrollment in the PrOMIS study).

  15. High rectification ratios of Fe-porphyrin molecules on Au facets

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaoyu; Wang, Gwo-Ching [Department of Physics, Applied Physics and Astronomy, Rensselaer Polytechnic Institute, 110, 8th Street, Troy, NY 12180 (United States); Lewis, Kim M., E-mail: lewisk2@rpi.edu [Department of Physics, Applied Physics and Astronomy, Rensselaer Polytechnic Institute, 110, 8th Street, Troy, NY 12180 (United States)

    2012-09-14

    We report room temperature measurements of current vs. voltage (I-V) from self-assembled Fe porphyrin [Fe(III) 5,15-di[4-(s-acetylthio)phenyl]-10,20-diphenyl porphine] molecular layers formed on annealed gold crystal facets on glass substrates. I-V curves were measured using an atomic force microscope with a conductive platinum tip. We observed a rectifier effect that shows asymmetric I-V curves from a monolayer of molecules. The majority rectification ratios at {+-}1 V obtained from hundreds of I-V lie in between 20 and 200, with the highest up to 9000. This is in contrast to the symmetric I-V curves measured from a few nm thick multilayer molecular islands. We contribute the observed rectification in ultrathin FeP molecular layers from asymmetric Schottky barriers that result from molecules in different bonding strengths to electrodes of gold and platinum. -- Highlights: Black-Right-Pointing-Pointer FeP molecular layers or islands of different thickness were self-assembled on Au. Black-Right-Pointing-Pointer High rectification ratios up to 9000 observed in sub-nm thick FeP molecular layers. Black-Right-Pointing-Pointer Measured current vs. voltage using a conductive AFM tip as one electrode. Black-Right-Pointing-Pointer Observed rectification of symmetric molecules using two different electrodes.

  16. Sacroiliac Joint/Sacrum Uptake Ratio Measured by Quantitative Sacroiliac Joint Scintigraphy

    International Nuclear Information System (INIS)

    Lee, Young Yiul; Park, Seon Yang; Lee, Myung Chul; Choi, Sang Jae; Cho, Bo Youn; Choe, Kang Won; Koh, Chang Soon

    1982-01-01

    To evaluate the diagnostic usefulness and significance of quantitative sacroiliac joint scintigraphy in the assessment of sacroiliitis, we measured Sacroiliac Joint/Sacrum Uptake Ratio (SIS Ratio) by region of interest (ROI) method using 99m Tc-methylene diphosphonate. The observed results were as follows:1) Using ROI method, the SIS ratios for the control group of 65 persons were 1.05±0.08 (left) and 1.06±0.07 (right) which were narrower in range than those of slice method (mean±S.D.) 2) The effects of age, gender and laterality on SIS ratio were not significant. 3) In left side, one of 6 patients with rheumatoid arthritis had SIS ratio in excess of 2 standard deviation of normal control group, and remainder had SIS ratios within normal limit. In right side, 3 patients had SIS ratios in excess of 2 standard deviation of normal control group, and remainder, within normal limit. 4) In both sacroiliac joint, 2 of 3 patients having sacroiliitis clinically with Reiter's syndrome whose pelvis A-P X-ray findings showed normal had high SIS ratios (left/right; 1.31/1.69, 1.90/1.80), but SIS ratio of one patient who bad no evidence of sacroiliitis clinically was within normal limit. 5) In 6 patients with ankylosing spondylitis in both sacroiliac joints, q whose pelvis A-P X-ray findings showed severe sclerotic change of sacroiliac pints had SIS ratio within normal limit or below that of normal control group, and SIS ratios of 2 patients whose pelvis A-P X-ray findings showed were increased. 6) 4 of 5 patients with low back pain of which cause could not be evaluated clinically and radiologically had SIS ratios in excess of that of normal control group. It would be concluded the quantitative sacroiliac joint scintigraphy is useful and sensitive screening method in the diagnosis as well as in the assessment clinical activity of sacroiliitis.

  17. Examining the Influence of Self-Efficacy and Self-Regulation in Online Learning

    Science.gov (United States)

    Bradley, Rachel L.; Browne, Blaine L.; Kelley, Heather M.

    2017-01-01

    This paper examined self-efficacy and self-regulatory skills and their influence on achievement in an online learning environment. This study utilized the Online Academic Success Indicators Scale (OASIS). The results of the scale were compared to previous tests measuring the predictive nature of self-efficacy and self-regulatory skills on academic…

  18. Shape coexistence from lifetime and branching-ratio measurements in 68,70Ni

    Directory of Open Access Journals (Sweden)

    B.P. Crider

    2016-12-01

    Full Text Available Shape coexistence near closed-shell nuclei, whereby states associated with deformed shapes appear at relatively low excitation energy alongside spherical ones, is indicative of the rapid change in structure that can occur with the addition or removal of a few protons or neutrons. Near 68Ni (Z=28, N=40, the identification of shape coexistence hinges on hitherto undetermined transition rates to and from low-energy 0+ states. In 68,70Ni, new lifetimes and branching ratios have been measured. These data enable quantitative descriptions of the 0+ states through the deduced transition rates and serve as sensitive probes for characterizing their nuclear wave functions. The results are compared to, and consistent with, large-scale shell-model calculations which predict shape coexistence. With the firm identification of this phenomenon near 68Ni, shape coexistence is now observed in all currently accessible regions of the nuclear chart with closed proton shells and mid-shell neutrons.

  19. Evaluation of flurbiprofen urinary ratios as in vivo indices for CYP2C9 activity

    Science.gov (United States)

    Zgheib, N K; Frye, R F; Tracy, T S; Romkes, M; Branch, R A

    2007-01-01

    Aims We investigated flurbiprofen pharmacokinetics in 12 volunteers to develop a phenotypic trait measure that correlates with the fractional clearance to 4′-hydroxyflurbiprofen. The effect of the CYP2C9 inhibitor fluconazole on flurbiprofen metabolism was also evaluated. Methods Flurbiprofen pharmacokinetics were evaluated before and after the first and seventh doses of fluconazole. The urinary recovery ratio was calculated as FLRR = 4′-OHF/ [4′-OHF + Ftot] and the urinary metabolic ratio was calculated as FLMR = 4′-OHF/Ftot, where 4′-OHF and Ftot represent total (conjugated and unconjugated) amounts recovered in urine. Results There was a statistically significant relationship between the 4′-OHF formation clearance (4OHCLf) and both the 8-h FLRR and the 8-h FLMR with and without administration of fluconazole. The flurbiprofen apparent oral clearance (CL/F) was decreased by 53% [90% confidence interval (CI) −58, −48] and 64% (90% CI −69, −59), respectively, after administration of one and seven doses of fluconazole when compared with administration of flurbiprofen alone; similarly, the 4OHCLf decreased by 69% (90% CI −74, −64) and 78% (90% CI −83, −73), the 8-h FLRR decreased by 35% (90% CI −41, −29) and 40% (90% CI −46, −35) and the 8-h FLMR decreased by 61% (90% CI −65, −58) and 67% (90% CI −70, −63). The magnitude of decrease in CL/F and 4OHCLf was greater after seven doses compared with after one dose of fluconazole (P < 0.005). Conclusions This study provides strong evidence that both the 8-h FLRR and the 8-h FLMR are suitable phenotypic indices for CYP2C9 activity. PMID:17054666

  20. The measurement and interpretation of Ne VII spectral line intensity ratios

    International Nuclear Information System (INIS)

    Lang, J.

    1983-03-01

    Results are presented for the measurement, using the branching ratios calibration method, of the spectral intensities of Ne VII lines emitted from a theta-pinch plasma whose electron temperature and density have been found by laser scattering and alternate techniques. (author)

  1. Development and Validation of a Self-Report Measure of Mentalizing: The Reflective Functioning Questionnaire.

    Directory of Open Access Journals (Sweden)

    Peter Fonagy

    Full Text Available Reflective functioning or mentalizing is the capacity to interpret both the self and others in terms of internal mental states such as feelings, wishes, goals, desires, and attitudes. This paper is part of a series of papers outlining the development and psychometric features of a new self-report measure, the Reflective Functioning Questionnaire (RFQ, designed to provide an easy to administer self-report measure of mentalizing. We describe the development and initial validation of the RFQ in three studies. Study 1 focuses on the development of the RFQ, its factor structure and construct validity in a sample of patients with Borderline Personality Disorder (BPD and Eating Disorder (ED (n = 108 and normal controls (n = 295. Study 2 aims to replicate these findings in a fresh sample of 129 patients with personality disorder and 281 normal controls. Study 3 addresses the relationship between the RFQ, parental reflective functioning and infant attachment status as assessed with the Strange Situation Procedure (SSP in a sample of 136 community mothers and their infants. In both Study 1 and 2, confirmatory factor analyses yielded two factors assessing Certainty (RFQ_C and Uncertainty (RFQ_U about the mental states of self and others. These two factors were relatively distinct, invariant across clinical and non-clinical samples, had satisfactory internal consistency and test-retest stability, and were largely unrelated to demographic features. The scales discriminated between patients and controls, and were significantly and in theoretically predicted ways correlated with measures of empathy, mindfulness and perspective-taking, and with both self-reported and clinician-reported measures of borderline personality features and other indices of maladaptive personality functioning. Furthermore, the RFQ scales were associated with levels of parental reflective functioning, which in turn predicted infant attachment status in the SSP. Overall, this study lends

  2. Building a Self: Teenaged Girls and Issues of Self-Esteem.

    Science.gov (United States)

    Flansburg, Sundra

    1991-01-01

    This newsletter summarizes the current state of understanding about self-esteem in teenaged girls. It notes that self-esteem is a concept that is difficult to define and to measure. Current research indicates that self-esteem is composed of many factors; however, a reasonable functional definition is the value a person places on herself or…

  3. Measuring self-esteem after spinal cord injury: Development, validation and psychometric characteristics of the SCI-QOL Self-esteem item bank and short form.

    Science.gov (United States)

    Kalpakjian, Claire Z; Tate, Denise G; Kisala, Pamela A; Tulsky, David S

    2015-05-01

    To describe the development and psychometric properties of the Spinal Cord Injury-Quality of Life (SCI-QOL) Self-esteem item bank. Using a mixed-methods design, we developed and tested a self-esteem item bank through the use of focus groups with individuals with SCI and clinicians with expertise in SCI, cognitive interviews, and item-response theory-(IRT) based analytic approaches, including tests of model fit, differential item functioning (DIF) and precision. We tested a pool of 30 items at several medical institutions across the United States, including the University of Michigan, Kessler Foundation, the Rehabilitation Institute of Chicago, the University of Washington, Craig Hospital, and the James J. Peters/Bronx Department of Veterans Affairs hospital. A total of 717 individuals with SCI completed the self-esteem items. A unidimensional model was observed (CFI=0.946; RMSEA=0.087) and measurement precision was good (theta range between -2.7 and 0.7). Eleven items were flagged for DIF; however, effect sizes were negligible with little practical impact on score estimates. The final calibrated item bank resulted in 23 retained items. This study indicates that the SCI-QOL Self-esteem item bank represents a psychometrically robust measurement tool. Short form items are also suggested and computer adaptive tests are available.

  4. "Is there an Association Between Self-Reported Sleep Duration, Body Mass Index and Waist-Hip Ratio in Young Adults? A Cross-Sectional Pilot Study".

    Science.gov (United States)

    Kamath, M Ganesh; Prakash, Jay; Dash, Sambit; Chowdhury, Sudipta; Ahmed, Zuhilmi Bin; Yusof, Muhammad Zaim Zharif Bin Mohd

    2014-09-01

    Sleep is vital for mental and physical health of an individual. Duration of sleep influences the metabolism and regulates body weight. To assess the cross-sectional association of sleep duration with body mass index (BMI) and waist-hip ratio in Malaysian students. Eighty-nine Malaysian students of both genders, and with a mean (standard deviation) age of 21.2 (0.9) years were included. Institutional Ethics Committee clearance was obtained prior to the start of study. The subjects were interviewed regarding the average hours of sleep/day, their self-reported sleep duration was categorized as 7hour/day. Their height (in meters), weight (in kilograms), waist and hip circumference (in centimetre) were measured. BMI and waist-hip ratio were calculated using appropriate formulas and expressed as mean (standard deviation). The duration of sleep was compared with BMI and waist-hip ratio using one way ANOVA. No statistical significance was observed when sleep duration was associated with BMI (p=0.65) and waist-hip ratio (p=0.95). Duration of sleep did not affect BMI and waist hip ratio in the Malaysian students in our study. The age and healthy lifestyle of the subjects in this study may have been a reason for no significant influence of short sleep duration on the BMI and waist-hip ratio. No association was found between sleep duration with BMI and waist hip ratio in the Malaysian students.

  5. Measurement of assertive behavior: construct and predictive validity of self-report, role-playing, and in-vivo measures.

    Science.gov (United States)

    Burkhart, B R; Green, S B; Harrison, W H

    1979-04-01

    Examined the predictive validity and construct equivalence of the three major procedures used to measure assertive behavior: Self-report, behavioral role-playing, and in-vivo assessment. Seventy-five Ss, who spanned the range of assertiveness, completed two self-report measures of assertiveness, the Rathus Assertiveness Scale (RAS) and the College Self-Expression Scale (CSES); two scales from the Endler S-R Inventory of General Trait Anxiousness, the interpersonal and general anxiety scales; eight role-playing situations that involved the expression of positive and negative assertiveness; and a telephone in-vivo task. In general, the study revealed the following: (1) assertiveness measures are task-dependent in that there was more overlap within task than between tasks; (2) there is a moderate degree of correspondence between self-report and role-playing measures, although this was true only for negative assertion; (3) positive and negative assertion do not appear to have the same topography of responding; and (4) there appears to be no consistent relationship between the in-vivo measure and any other type of assertiveness measure.

  6. Systematic review of self-concept measures for primary school aged children with cerebral palsy.

    Science.gov (United States)

    Cheong, Sau Kuan; Johnston, Leanne M

    2013-10-01

    This study involved a systematic review aimed to identify self-concept measures that provided published psychometrics for primary school aged children (8-12 years) with cerebral palsy (CP). Six electronic databases (PubMed, MEDLINE, CINAHL, PsycINFO, PsycARTICLES and Web of Science) were searched to identify assessments that (1) measured self-concept; (2) in children aged 8-12 years; (3) with CP; (4) with psychometrics available. The Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN) checklist was used to evaluate psychometric properties and the CanChild Outcome Measure Rating Form was used to evaluate clinical utility. Search yielded 271 papers, of which five met inclusion criteria. These papers reported five measures of self-concept with psychometric properties for the target population: the Rosenberg Self-Esteem Index, Self-Description Questionnaire-I, Self-Perception Profile for Children (original) and two separate modifications of the Self-Perception Profile for Children. Currently, no self-concept measures published in English had sufficient psychometric data for children with CP. The Self-Description Questionnaire-I and the Self-Perception Profile for Children were promising options. Further research is required (a) to determine self-concept construct components important for children with CP and (b) to examine the relative strength, validity, reliability and clinical utility of self-concept measures for the target population. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy.

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-21

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR 20,10 , using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR 20,10 . With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR 20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR 20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR 20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR 20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR 20,10 value.

  8. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-01

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR20,10, using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR20,10. With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR20,10 value.

  9. Defining and Measuring Cognitive-Entropy and Cognitive Self-Synchronization

    Science.gov (United States)

    2011-06-01

    16th ICCRTS: “Collective C2 in Multinational Civil-Military Operations” Defining and Measuring Cognitive-Entropy and Cognitive Self- Synchronization ...shared awareness and enabling self- synchronization across the range of participating entities (Alberts and Hayes 2009, pp.106). We consider the...aspect of self- synchronization (Alberts and Hayes, 2006) a key one in the context of modern operations and in performing C2 assessments. Based on (Manso

  10. Poisson's ratio of collagen fibrils measured by small angle X-ray scattering of strained bovine pericardium

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Hannah C.; Sizeland, Katie H.; Kayed, Hanan R.; Haverkamp, Richard G., E-mail: r.haverkamp@massey.ac.nz [School of Engineering and Advanced Technology, Massey University, Private Bag 11222, Palmerston North 4442 (New Zealand); Kirby, Nigel; Hawley, Adrian; Mudie, Stephen T. [Australian Synchrotron, 800 Blackburn Road, Clayton, Victoria 3168 (Australia)

    2015-01-28

    Type I collagen is the main structural component of skin, tendons, and skin products, such as leather. Understanding the mechanical performance of collagen fibrils is important for understanding the mechanical performance of the tissues that they make up, while the mechanical properties of bulk tissue are well characterized, less is known about the mechanical behavior of individual collagen fibrils. In this study, bovine pericardium is subjected to strain while small angle X-ray scattering (SAXS) patterns are recorded using synchrotron radiation. The change in d-spacing, which is a measure of fibril extension, and the change in fibril diameter are determined from SAXS. The tissue is strained 0.25 (25%) with a corresponding strain in the collagen fibrils of 0.045 observed. The ratio of collagen fibril width contraction to length extension, or the Poisson's ratio, is 2.1 ± 0.7 for a tissue strain from 0 to 0.25. This Poisson's ratio indicates that the volume of individual collagen fibrils decreases with increasing strain, which is quite unlike most engineering materials. This high Poisson's ratio of individual fibrils may contribute to high Poisson's ratio observed for tissues, contributing to some of the remarkable properties of collagen-based materials.

  11. Selective dopamine D3 receptor antagonism by SB-277011A attenuates cocaine reinforcement as assessed by progressive-ratio and variable-cost–variable-payoff fixed-ratio cocaine self-administration in rats

    Science.gov (United States)

    Xi, Zheng-Xiong; Gilbert, Jeremy G.; Pak, Arlene C.; Ashby, Charles R.; Heidbreder, Christian A.; Gardner, Eliot L.

    2013-01-01

    In rats, acute administration of SB-277011A, a highly selective dopamine (DA) D3 receptor antagonist, blocks cocaine-enhanced brain stimulation reward, cocaine-seeking behaviour and reinstatement of cocaine-seeking behaviour. Here, we investigated whether SB-277011A attenuates cocaine reinforcement as assessed by cocaine self-administration under variable-cost–variable-payoff fixed-ratio (FR) and progressive-ratio (PR) reinforcement schedules. Acute i.p. administration of SB-277011A (3–24 mg/kg) did not significantly alter cocaine (0.75 mg/kg/infusion) self-administration reinforced under FR1 (one lever press for one cocaine infusion) conditions. However, acute administration of SB-277011A (24 mg/kg, i.p.) progressively attenuated cocaine self-administration when: (a) the unit dose of self-administered cocaine was lowered from 0.75 to 0.125–0.5 mg/kg, and (b) the work demand for cocaine reinforcement was increased from FR1 to FR10. Under PR (increasing number of lever presses for each successive cocaine infusion) cocaine reinforcement, acute administration of SB-277011A (6–24 mg/kg i.p.) lowered the PR break point for cocaine self-administration in a dose-dependent manner. The reduction in the cocaine (0.25–1.0 mg/kg) dose–response break-point curve produced by 24 mg/kg SB-277011A is consistent with a reduction in cocaine’s reinforcing efficacy. When substituted for cocaine, SB-277011A alone did not sustain self-administration behaviour. In contrast with the mixed DA D2/D3 receptor antagonist haloperidol (1 mg/kg), SB-277011A (3, 12 or 24 mg/kg) failed to impede locomotor activity, failed to impair rearing behaviour, failed to produce catalepsy and failed to impair rotarod performance. These results show that SB-277011A significantly inhibits acute cocaine-induced reinforcement except at high cocaine doses and low work requirement for cocaine. If these results extrapolate to humans, SB-277011A or similar selective DA D3 receptor antagonists may be

  12. Self-recalibration of a robot-assisted structured-light-based measurement system.

    Science.gov (United States)

    Xu, Jing; Chen, Rui; Liu, Shuntao; Guan, Yong

    2017-11-10

    The structured-light-based measurement method is widely employed in numerous fields. However, for industrial inspection, to achieve complete scanning of a work piece and overcome occlusion, the measurement system needs to be moved to different viewpoints. Moreover, frequent reconfiguration of the measurement system may be needed based on the size of the measured object, making the self-recalibration of extrinsic parameters indispensable. To this end, this paper proposes an automatic self-recalibration and reconstruction method, wherein a robot arm is employed to move the measurement system for complete scanning; the self-recalibration is achieved using fundamental matrix calculations and point cloud registration without the need for an accurate calibration gauge. Experimental results demonstrate the feasibility and accuracy of our method.

  13. Physicochemical and biological properties of self-assembled antisense/poly(amidoamine dendrimer nanoparticles: the effect of dendrimer generation and charge ratio

    Directory of Open Access Journals (Sweden)

    Alireza Nomani

    2010-05-01

    Full Text Available Alireza Nomani1,6, Ismaeil Haririan1,5, Ramin Rahimnia2,4, Shamileh Fouladdel2, Tarane Gazori1, Rassoul Dinarvand1, Yadollah Omidi3, Ebrahim Azizi2,41Department of Pharmaceutics, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran; 2Molecular Research Lab, Department of Pharmacology and Toxicology, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran; 3Department of Pharmaceutics, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran; 4Department of Medical Biotechnology, School of Advanced Medical Technologies, Tehran University of Medical Sciences, Tehran, Iran; 5Biomaterials Research Center (BRC Tehran, Iran; 6Department of Pharmaceutics, Faculty of Pharmacy, Zanjan University of Medical Sciences, Zanjan, IranAbstract: To gain a deeper understanding of the physicochemical phenomenon of self-assembled nanoparticles of different generations and ratios of poly (amidoamine dendrimer (PAMAM dendrimer and a short-stranded DNA (antisense oligonucleotide, multiple methods were used to characterize these nanoparticles including photon correlation spectroscopy (PCS; zeta potential measurement; and atomic force microscopy (AFM. PCS and AFM results revealed that, in contrast to larger molecules of DNA, smaller molecules produce more heterodisperse and large nanoparticles when they are condensed with a cationic dendrimer. AFM images also showed that such nanoparticles were spherical. The stability of the antisense content of the nanoparticles was investigated over different charge ratios using polyacrylamide gel electrophoresis. It was clear from such analyses that much more than charge neutrality point was required to obtain stable nanoparticles. For cell uptake, self-assembled nanoparticles were prepared with PAMAM G5 and 5’-FITC labeled antisense and the uptake experiment was carried out in T47D cell culture. This investigation also shows that the cytotoxicity of the nanoparticles was

  14. Simulation and Measurement of Neuroelectrodes' Characteristics with Integrated High Aspect Ratio Nano Structures

    Directory of Open Access Journals (Sweden)

    Christoph Nick

    2015-07-01

    Full Text Available Improving the interface between electrodes and neurons has been the focus of research for the last decade. Neuroelectrodes should show small geometrical surface area and low impedance for measuring and high charge injection capacities for stimulation. Increasing the electrochemically active surface area by using nanoporous electrode material or by integrating nanostructures onto planar electrodes is a common approach to improve this interface. In this paper a simulation approach for neuro electrodes' characteristics with integrated high aspect ratio nano structures based on a point-contact-model is presented. The results are compared with experimental findings conducted with real nanostructured microelectrodes. In particular, effects of carbon nanotubes and gold nanowires integrated onto microelectrodes are described. Simulated and measured impedance properties are presented and its effects onto the transfer function between the neural membrane potential and the amplifier output signal are studied based on the point-contact-model. Simulations show, in good agreement with experimental results, that electrode impedances can be dramatically reduced by the integration of high aspect ratio nanostructures such as gold nanowires and carbon nanotubes. This lowers thermal noise and improves the signal-to-noise ratio for measuring electrodes. It also may increase the adhesion of cells to the substrate and thus increase measurable signal amplitudes.

  15. A New Strategy for Utilizing Rice Forage Production Using a No-Tillage System to Enhance the Self-Sufficient Feed Ratio of Small Scale Dairy Farming in Japan

    Directory of Open Access Journals (Sweden)

    Windi Al Zahra

    2014-08-01

    Full Text Available Rice forage systems can increase the land use efficiency in paddy fields, improve the self-sufficient feed ratio, and provide environmental benefits for agro-ecosystems. This system often decreased economic benefits compared with those through imported commercial forage feed, particularly in Japan. We observed the productivities of winter forage after rice harvest between conventional tillage (CT and no-tillage (NT in a field experiment. An on-farm evaluation was performed to determine the self-sufficient ratio of feed and forage production costs based on farm evaluation of the dairy farmer and the rice grower, who adopted a rice forage system. The field experiment detected no significant difference in forage production and quality between CT and NT after rice harvest. However, the production cost was dramatically decreased by 28.1% in NT compared with CT. The self-sufficient ratio was 5.4% higher when dairy farmers adopted the rice forage system compared with those using the current management system. Therefore, this study demonstrated the positive benefits for dairy farmers and rice growers in Japan when adopting a rice forage system with NT, which could improve the self-sufficient feed ratio and reduce production costs.

  16. Developing and validating an instrument for measuring mobile computing self-efficacy.

    Science.gov (United States)

    Wang, Yi-Shun; Wang, Hsiu-Yuan

    2008-08-01

    IT-related self-efficacy has been found to have a critical influence on system use. However, traditional measures of computer self-efficacy and Internet-related self-efficacy are perceived to be inapplicable in the context of mobile computing and commerce because they are targeted primarily at either desktop computer or wire-based technology contexts. Based on previous research, this study develops and validates a multidimensional instrument for measuring mobile computing self-efficacy (MCSE). This empirically validated instrument will be useful to researchers in developing and testing the theories of mobile user behavior, and to practitioners in assessing the mobile computing self-efficacy of users and promoting the use of mobile commerce systems.

  17. Measurement of the cosmic ray muon charge ratio with the OPERA detector

    International Nuclear Information System (INIS)

    Mauri, N.; Sioli, M.

    2012-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the cosmic ray muon charge ratio R μ =N μ + /N μ − in the TeV energy region. R μ is shown as a function of the “vertical surface energy” E μ cosθ. A fit to a simplified model of muon production in atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.

  18. Analytical treatment of the relationships between soil heat flux/net radiation ratio and vegetation indices

    International Nuclear Information System (INIS)

    Kustas, W.P.; Daughtry, C.S.T.; Oevelen, P.J. van

    1993-01-01

    Relationships between leaf area index (LAI) and midday soil heat flux/net radiation ratio (G/R n ) and two more commonly used vegetation indices (VIs) were used to analytically derive formulas describing the relationship between G/R n and VI. Use of VI for estimating G/R n may be useful in operational remote sensing models that evaluate the spatial variation in the surface energy balance over large areas. While previous experimental data have shown that linear equations can adequately describe the relationship between G/Rn and VI, this analytical treatment indicated that nonlinear relationships are more appropriate. Data over bare soil and soybeans under a range of canopy cover conditions from a humid climate and data collected over bare soil, alfalfa, and cotton fields in an arid climate were used to evaluate model formulations derived for LAI and G/R n , LAI and VI, and VI and G/R n . In general, equations describing LAI-G/R n and LAI-VI relationships agreed with the data and supported the analytical result of a nonlinear relationship between VI and G/R n . With the simple ratio (NIR/Red) as the VI, the nonlinear relationship with G/R n was confirmed qualitatively. But with the normalized difference vegetation index (NDVI), a nonlinear relationship did not appear to fit the data. (author)

  19. Accuracy of signal-to-noise ratio measurement method for magnetic resonance images

    International Nuclear Information System (INIS)

    Ogura, Akio; Miyai, Akira; Maeda, Fumie; Fukutake, Hiroyuki; Kikumoto, Rikiya

    2003-01-01

    The signal-to-noise ratio (SNR) of a magnetic resonance image is a common measure of imager performance. However, evaluations for the calculation of the SNR use various methods. A problem with measuring SNR is caused by the distortion of noise statistics in commonly used magnitude images. In this study, measurement accuracy was compared among four methods of evaluating SNR according to the size and position of regions of interest (ROIs). The results indicated that the method that used the difference between two images showed the best agreement with the theoretical value. In the method that used a single image, the SNR calculated by using a small size of ROI showed better agreement with the theoretical value because of noise bias and image artifacts. However, in the method that used the difference between two images, a large size of ROI was better in reducing statistical errors. In the same way, the methods that used air noise and air signal were better when applied to a large ROI. In addition, the image subtraction process used to calculate pixel-by-pixel differences in images may reach zero on a minus pixel value when using an image processor with the MRI system and apparatuses associated with it. A revised equation is presented for this case. It is important to understand the characteristics of each method and to choose a suitable method carefully according to the purpose of the study. (author)

  20. Self-Efficacy and the Self-Monitoring of Selected Exercise and Eating Behaviors of College Students.

    Science.gov (United States)

    Kingery, Paul M.

    1990-01-01

    Results from a study of 85 college students indicate that self-efficacy is a moderately strong predictor of self-monitored performance of dietary and exercise behaviors when measured following a self-monitored performance attempt. (IAH)

  1. Constructing Indicators for Measuring Provincial Sustainable Development Index in Vietnam

    Science.gov (United States)

    Truong, Van Canh; Lisowski, Andrzej

    2018-03-01

    Sustainable development is zeitgeist of our age. It is one kind of development that in this trajectory humanity can create a stable and developed socio-economic foundations, conserve environment and therefore able to continue for a long time. Using indicators is one of the best ways to monitor and measure the progress toward sustainable development. In this paper we have proposed the way to create indicators for measuring provincial sustainable development index in Vietnam. We firstly made a framework of elements for economic, social and environmental component and compiled a list of indicators of 20 national and international agencies in the world. We then applied the SMART framework (Specific, Measurable, Achievable, Relevant, and Time-related) to choose indicators which will be relevant for Vietnam and put them back to the elements. We then have 39 relevant indicators with 12 indicators for economy, 17 indicators for social and 10 indicators for environmental component. Finally, we have established the way to determine the worst and best value for each indicator from available data for countries in the world.

  2. RELATIONSHIP BETWEEN THE LEVEL OF SELF-EFFICACY, PERFORMANCE INDICATORS, AND PARTICIPATION IN YOUTH BASKETBALL

    Directory of Open Access Journals (Sweden)

    Enrique Ortega

    2009-01-01

    Full Text Available The present study analyzed the relationship between the level of self-efficacy of the player with the ball in basketball, various performance indicators, and individual participation of the youth player in competition, with the goal of being able to establish initial values that help to define game styles and systems that are adapted to the characteristics of the youth player. In order to evaluate the levels of self-efficacy, a questionnaire was administered to 187 players from the under-16 age category. From a total of 22 games, the following variables related to the individual performance of the player were analyzed: a points scored; b shot attempts and shots made of 1, 2, and 3 points; c efficacy percentage of 1, 2, and 3-point shots; d rebounds made; and e personal fouls received. With regard to participation, the following variables were analyzed: f minutes played; g total time of ball possession; h number of ball possessions; i number of passes received; and j number of offensive phases in which the player participates. The results indicate that the performance and participation variables correctly classify 74.2% when differentiating between players with high and low levels of selfefficacy. The players with high levels of self-efficacy presented higher values in the different performance and participation variables than the players with low levels of self-efficacy.

  3. Measurement of the tau lifetime and leptonic branching ratios in L3

    International Nuclear Information System (INIS)

    Garcia-Abia, P.

    2001-01-01

    Using data collected with the L3 detector near the Z resonance corresponding to an integrated luminosity of 150 pb -1 the lifetime of the tau lepton is measured to be τ τ = 293.2 ± 2.0(stat.) ± 1.5(sys.) fs, and the branching ratios of the tau lepton into electron and muon are measured to be B(τ → eν-bar e ν τ ) = (17.806 ± 0.104 (stat.)±0.076(sys.))% and B(τ → μν-bar μ ν τ ) = (17.342 ± 0.110 (stat.)±0.067(sys.))%, respectively. From these results the ratio of the charged current coupling constants g μ /g e , g τ /g e and g τ /g μ are determined and support the lepton universality hypothesis. The Fermi-constant and the coupling constant of the strong interaction at the tau mass are obtained from these measurements

  4. Technical note: using Distributed Temperature Sensing for Bowen ratio evaporation measurements

    NARCIS (Netherlands)

    Schilperoort, B.; Coenders, Miriam; Luxemburg, W.M.J.; Jimenez Rodriguez, C.D.; Cisneros Vaca2, C.; Savenije, Hubert

    2017-01-01

    Rapid improvements in the precision and spatial resolution of Distributed Temperature Sensing (DTS) technology now allows its use in hydrological and atmospheric sciences. Introduced by Euser [Hydrol. Earth Syst. Sci., 18, 2021–2032 (2014)] is the use of DTS for measuring the Bowen ratio (BR-DTS),

  5. Self-reported difficulty in conceiving as a measure of infertility.

    Science.gov (United States)

    Dick, M-L B; Bain, C J; Purdie, D M; Siskind, V; Molloy, D; Green, A C

    2003-12-01

    This study aimed to explore the meaning and potential use of women's self-reported difficulties in conceiving as a measure of infertility in epidemiological studies, and to compare women's stated reasons for infertility with information in their medical records. Data were available from a population-based case-control study of ovarian cancer involving 1638 women. The sensitivity and specificity of women's self-reported infertility were calculated against their estimated fertility status based on detailed reproductive histories. Self-reported reasons for infertility were compared with diagnoses documented in women's medical records. The sensitivity of women's self-reported difficulty in conceiving was 66 and 69% respectively when compared with calendar-derived and self-reported times taken trying to conceive; its specificity was 95%. Forty-one (23%) of the 179 women for whom medical records were available had their self-reported fertility problem confirmed. Self-reported infertility causes could be compared with diagnoses in medical records for only 22 of these women. Self-reported difficulty conceiving is a useful measure of infertility for quantifying the burden of fertility problems experienced in the community. Validation of reasons for infertility is unlikely to be feasible through examination of medical records. Improved education of the public regarding the availability and success rates of infertility treatments is proposed.

  6. Strain ratio measurement of femoral cartilage by real-time elastosonography: preliminary results

    International Nuclear Information System (INIS)

    Ipek, Ali; Unal, Ozlem; Kartal, Merve Gulbiz; Arslan, Halil; Isik, Cetin; Bozkurt, Murat

    2015-01-01

    The purpose of this study was to evaluate strain ratio measurement of femoral cartilage using real-time elastosonography. Twenty-five patients with femoral cartilage pathology on MRI (study group) were prospectively compared with 25 subjects with normal findings on MRI (control group) using real-time elastosonography. Strain ratio measurements of pathologic and normal cartilage were performed and compared, both within the study group and between the two groups. Elastosonography colour-scale coding showed a colour change from blue to red in pathologic cartilage and only blue colour-coding in normal cartilage. In the study group, the median strain ratio was higher in pathologic cartilage areas compared to normal areas (median, 1.49 [interquartile range, 0.80-2.53] vs. median, 0.01 [interquartile range, 0.01-0.01], p < 0.001, respectively). The median strain ratio of the control group was 0.01 (interquartile range, 0.01-0.01), and there was no significant difference compared to normal areas of the study group. There was, however, a significant difference between the control group cartilage and pathologic cartilage of the study group (p < 0.001). Elastosonography may be an effective, easily accessible, and relatively simple tool to demonstrate pathologic cartilage and to differentiate it from normal cartilage in the absence of advanced imaging facility such as MRI. (orig.)

  7. Correction of self-reported BMI based on objective measurements: a Belgian experience.

    Science.gov (United States)

    Drieskens, S; Demarest, S; Bel, S; De Ridder, K; Tafforeau, J

    2018-01-01

    Based on successive Health Interview Surveys (HIS), it has been demonstrated that also in Belgium obesity, measured by means of a self-reported body mass index (BMI in kg/m 2 ), is a growing public health problem that needs to be monitored as accurately as possible. Studies have shown that a self-reported BMI can be biased. Consequently, if the aim is to rely on a self-reported BMI, adjustment is recommended. Data on measured and self-reported BMI, derived from the Belgian Food Consumption Survey (FCS) 2014 offers the opportunity to do so. The HIS and FCS are cross-sectional surveys based on representative population samples. This study focused on adults aged 18-64 years (sample HIS = 6545 and FCS = 1213). Measured and self-reported BMI collected in FCS were used to assess possible misreporting. Using FCS data, correction factors (measured BMI/self-reported BMI) were calculated in function of a combination of background variables (region, gender, educational level and age group). Individual self-reported BMI of the HIS 2013 were then multiplied with the corresponding correction factors to produce a corrected BMI-classification. When compared with the measured BMI, the self-reported BMI in the FCS was underestimated (mean 0.97 kg/m 2 ). 28% of the obese people underestimated their BMI. After applying the correction factors, the prevalence of obesity based on HIS data significantly increased (from 13% based on the original HIS data to 17% based on the corrected HIS data) and approximated the measured one derived from the FCS data. Since self-reported calculations of BMI are underestimated, it is recommended to adjust them to obtain accurate estimates which are important for decision making.

  8. Beyond dual systems: A genetically-informed, latent factor model of behavioral and self-report measures related to adolescent risk-taking

    Directory of Open Access Journals (Sweden)

    K. Paige Harden

    2017-06-01

    Full Text Available The dual systems model posits that adolescent risk-taking results from an imbalance between a cognitive control system and an incentive processing system. Researchers interested in understanding the development of adolescent risk-taking use a diverse array of behavioral and self-report measures to index cognitive control and incentive processing. It is currently unclear whether different measures commonly interpreted as indicators of the same psychological construct do, in fact, tap the same underlying dimension of individual differences. In a diverse sample of 810 adolescent twins and triplets (M age = 15.9 years, SD = 1.4 years from the Texas Twin Project, we investigated the factor structure of fifteen self-report and task-based measures relevant to adolescent risk-taking. These measures can be organized into four factors, which we labeled premeditation, fearlessness, cognitive dyscontrol, and reward seeking. Most behavioral measures contained large amounts of task-specific variance; however, most genetic variance in each measure was shared with other measures of the corresponding factor. Behavior genetic analyses further indicated that genetic influences on cognitive dyscontrol overlapped nearly perfectly with genetic influences on IQ (rA = −0.91. These findings underscore the limitations of using single laboratory tasks in isolation, and indicate that the study of adolescent risk taking will benefit from applying multimethod approaches.

  9. Measurements of spectral indices in homogeneous multiplying media; Mesures d'indices de spectre dans les milieux multiplicateurs homogenes

    Energy Technology Data Exchange (ETDEWEB)

    Bruna, J G; Brunet, J P; Clouet D' Orval, Ch; Verriere, Ph; Kremser, J; Moret-Bailly, J; Tellier, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    Methods for computation of spectra in light water are developed at Saclay and it is interesting to carry out at the same time experimental studies of simple media such as solutions of fissionable salts which allow quite direct comparisons with computed values. The spectral indices measurements were made with two small fission chambers, one containing deposited plutonium, the other deposited uranium 235. Their response, when neutron spectrum is modified, allows to study the epithermal part of the flux. The media studied with these chambers are fissionable solutions (of plutonium or 90 per cent enriched uranium) which were made critical in bare cylindrical geometry in the Alecto reactor. If the ratio of the chambers is normalized to unity in a Maxwell spectrum, then the noted variation of the ratio of the counts Pu chamber/ U{sup 235} chamber reaches 1,4 in the range of the studied concentrations. (authors) [French] Des calculs de spectres dans l'eau legere sont mis au point a Saclay et il est interessant de mener parallelement des etudes experimentale sur des milieux simples tels que des solutions de sels fissiles, qui permettent des comparaisons tres directes avec les valeurs calculees. On a choisi d'effectuer des mesures d' 'indices de spectres' a l'aide de de deux petites chambres a fission contenant des depots, l'une de plutonium, l'autre d'uranium 235. Leur reponse lorsque le spectre des neutrons est modifie permet d'etudier la partie epithermique du flux. Les milieux etudies a l'aide de ces chambres sont des solutions fissiles (plutonium ou uranium enrichi a 90 pour cent) rendus critiques, en geometrie cylindrique nue, dans le reacteur Alecto. Si le rapport des chambres est normalise a un dans un spectre de Maxwell, la variation constatee du rapport des comptages chambre Pu/ chambre U{sup 235} atteint, dans les gammes de concentrations etudiees, 1,4. (auteurs)

  10. Determination of Light Water Reactor Fuel Burnup with the Isotope Ratio Method

    International Nuclear Information System (INIS)

    Gerlach, David C.; Mitchell, Mark R.; Reid, Bruce D.; Gesh, Christopher J.; Hurley, David E.

    2007-01-01

    For the current project to demonstrate that isotope ratio measurements can be extended to zirconium alloys used in LWR fuel assemblies we report new analyses on irradiated samples obtained from a reactor. Zirconium alloys are used for structural elements of fuel assemblies and for the fuel element cladding. This report covers new measurements done on irradiated and unirradiated zirconium alloys, Unirradiated zircaloy samples serve as reference samples and indicate starting values or natural values for the Ti isotope ratio measured. New measurements of irradiated samples include results for 3 samples provided by AREVA. New results indicate: 1. Titanium isotope ratios were measured again in unirradiated samples to obtain reference or starting values at the same time irradiated samples were analyzed. In particular, 49Ti/48Ti ratios were indistinguishably close to values determined several months earlier and to expected natural values. 2. 49Ti/48Ti ratios were measured in 3 irradiated samples thus far, and demonstrate marked departures from natural or initial ratios, well beyond analytical uncertainty, and the ratios vary with reported fluence values. The irradiated samples appear to have significant surface contamination or radiation damage which required more time for SIMS analyses. 3. Other activated impurity elements still limit the sample size for SIMS analysis of irradiated samples. The sub-samples chosen for SIMS analysis, although smaller than optimal, were still analyzed successfully without violating the conditions of the applicable Radiological Work Permit

  11. An exploration of the impact of invalid MMPI-2 protocols on collateral self-report measure scores.

    Science.gov (United States)

    Forbey, Johnathan D; Lee, Tayla T C

    2011-11-01

    Although a number of studies have examined the impact of invalid MMPI-2 (Butcher et al., 2001) response styles on MMPI-2 scale scores, limited research has specifically explored the effects that such response styles might have on conjointly administered collateral self-report measures. This study explored the potential impact of 2 invalidating response styles detected by the Validity scales of the MMPI-2, overreporting and underreporting, on scores of collateral self-report measures administered conjointly with the MMPI-2. The final group of participants included in analyses was 1,112 college students from a Midwestern university who completed all measures as part of a larger study. Results of t-test analyses suggested that if either over- or underreporting was indicated by the MMPI-2 Validity scales, the scores of most conjointly administered collateral measures were also significantly impacted. Overall, it appeared that test-takers who were identified as either over- or underreporting relied on such a response style across measures. Limitations and suggestions for future study are discussed.

  12. The association between male-biased sex ratio and indicators of stress in red-spotted newts.

    Science.gov (United States)

    Aspbury, Andrea S; Grayson, Kristine L; Fantaye, Selamawit; Nichols, Ian; Myers-Burton, Miranda; Ortiz-Mangual, Xavier; Gabor, Caitlin R

    2017-05-01

    In populations with a male-biased operational sex ratio, coercive mating by males can have fitness consequences for females. One component of reduced fitness for females in populations with a male-biased OSR may be greater activation of the stress response, resulting in higher corticosterone release rates (CORT; a glucocorticoid stress hormone in amphibians). We test the hypothesis that a male-biased sex ratio affects female activity and release rates of CORT and testosterone (T) in male and female red-spotted newts (Notophthalmus viridescens). First, we evaluated if chemical cues from a male-biased sex ratio affect activity and CORT release rates in females. We predicted that females exposed to chemical cues of three males would be less active and have higher CORT release rates than those exposed to chemical cues of one male. Second, we measured CORT release rates of red-spotted newts in field enclosures with either a male-biased or a female-biased sex ratio. We predicted that females in the male-biased treatment would have higher CORT and T release rates than those in a female-biased treatment, owing to higher levels of male harassment. We also predicted that males would have higher CORT and T release rates in male-biased treatments due to higher levels of male-male competition. Females were not less active in response to chemical cues from more males over fewer males, but there was a positive relationship between female activity and CORT when they were exposed to the cues of three males. We also found that females, but not males, in the male-biased sex ratio treatment had higher CORT and T release rates than those in the female-biased treatment. Our results support the hypothesis that a male-biased sex ratio leads to a higher stress response, which may underlie the observed decrease in immune function and body condition in previous work exposing female red-spotted newts to a male-biased sex ratio. This study furthers our understanding of the mechanistic basis

  13. Perceived academic performance, self-esteem and locus of control as indicators of need for assessment of adolescent suicide risk: implications for teachers.

    Science.gov (United States)

    Martin, Graham; Richardson, Angela S; Bergen, Helen A; Roeger, Leigh; Allison, Stephen

    2005-02-01

    There is currently a need for research into indicators that could be used by non-clinical professionals working with young people, to inform the need for referral for further clinical assessment of those at risk of suicide. Participants of this repeated measures longitudinal study, were 2603, 2485, and 2246 school students aged 13, 14, and 15, respectively, from 27 South Australian Schools. Perceived academic performance, self-esteem and locus of control are significantly associated with suicidality. Further, logistic regression of longitudinal results suggests that perceived academic performance, over and above self-esteem and locus of control, in some instances, is a good long-term predictor of suicidality.

  14. The validity of self-reported vs. measured body weight and height and the effect of self-perception.

    Science.gov (United States)

    Gokler, Mehmet Enes; Bugrul, Necati; Sarı, Ahu Ozturk; Metintas, Selma

    2018-01-01

    The objective was to assess the validity of self-reported body weight and height and the possible influence of self-perception of body mass index (BMI) status on the actual BMI during the adolescent period. This cross sectional study was conducted on 3918 high school students. Accurate BMI perception occurred when the student's self-perception of their BMI status did not differ from their actual BMI based on measured height and weight. Agreement between the measured and self-reported body height and weight and BMI values was determined using the Bland-Altman metod. To determine the effects of "a good level of agreement", hierarchical logistic regression models were used. Among male students who reported their BMI in the normal region, 2.8% were measured as overweight while 0.6% of them were measured as obese. For females in the same group, these percentages were 1.3% and 0.4% respectively. Among male students who perceived their BMI in the normal region, 8.5% were measured as overweight while 0.4% of them were measured as obese. For females these percentages were 25.6% and 1.8% respectively. According to logistic regression analysis, residence and accurate BMI perception were significantly associated with "good agreement" ( p ≤ 0.001). The results of this study demonstrated that in determining obesity and overweight statuses, non-accurate weight perception is a potential risk for students.

  15. Isomeric ratio measurements for the radiative neutron capture 176Lu(n,γ at DANCE

    Directory of Open Access Journals (Sweden)

    Denis-Petit D.

    2017-01-01

    Full Text Available The isomeric ratios for the neutron capture reaction 176Lu(n,γ to the Jπ = 5/2−, 761.7 keV, T1/2 = 32.8 ns and the Jπ = 15/2+, 1356.9 keV, T1/2 = 11.1 ns levels of 177Lu, have been measured for the first time with the Detector for Advanced Neutron Capture Experiments (DANCE at the Los Alamos National Laboratory. These measured isomeric ratios are compared with TALYS calculations.

  16. Can we measure daily tobacco consumption in remote indigenous communities? Comparing self-reported tobacco consumption with community-level estimates in an Arnhem Land study.

    Science.gov (United States)

    Clough, Alan R; MacLaren, David J; Robertson, Jan A; Ivers, Rowena G; Conigrave, Katherine M

    2011-03-01

    In remote Indigenous Australian communities measuring individual tobacco use can be confounded by cultural expectations, including sharing. We compared self-reported tobacco consumption with community-level estimates in Arnhem Land (Northern Territory). In a cross-sectional survey in three communities (population 2319 Indigenous residents, aged ≥16 years), 400 Indigenous residents were interviewed (206 men, 194 women). Eight community stores provided information about tobacco sold during the survey. To gauge the impact of 255 non-Indigenous residents on tobacco turnover, 10 were interviewed (five men, five women). Breath carbon monoxide levels confirmed self-reported smoking. Self-reported number of cigarettes smoked per day was compared with daily tobacco consumption per user estimated using amounts of tobacco sold during 12 months before the survey (2007-2008). 'Lighter smokers' (Indigenous study participants, 305 (76%) used tobacco; four chewed tobacco. Of 301 Indigenous smokers, 177 (58%) provided self-reported consumption information; a median of 11-11.5 cigarettes per day in men and 5.5-10 cigarettes per day in women. Men were three times (odds ratio=2.9) more likely to be 'heavier smokers'. Store turnover data indicated that Indigenous tobacco users consumed the equivalent of 9.2-13.1 cigarettes per day; very similar to self-reported levels. Sixty per cent (=6/10) of non-Indigenous residents interviewed were smokers, but with little impact on tobacco turnover overall (2-6%). Smoking levels reported by Indigenous Australians in this study, when sharing tobacco was considered, closely reflected quantities of tobacco sold in community stores. © 2010 Australasian Professional Society on Alcohol and other Drugs.

  17. When do ego threats lead to self-regulation failure? Negative consequences of defensive high self-esteem.

    Science.gov (United States)

    Lambird, Kathleen Hoffman; Mann, Traci

    2006-09-01

    High self-esteem (HSE) is increasingly recognized as heterogeneous. By measuring subtypes of HSE, the present research reevaluates the finding that HSE individuals show poor self-regulation following ego threat (Baumeister, Heatherton, & Tice, 1993). In Experiment 1, participants with HSE showed poor self-regulation after ego threat only if they also were defensive (high in self-presentation bias). In Experiment 2, two measures--self-presentation bias and implicit self-esteem--were used to subtype HSE individuals as defensive. Both operationalizations of defensive HSE predicted poor self-regulation after ego threat. The results indicate that (a) only defensive HSE individuals are prone to self-regulation failure following ego threat and (b) measures of self-presentation bias and implicit self-esteem can both be used to detect defensiveness.

  18. Measurement Noninvariance of Safer Sex Self-Efficacy Between Heterosexual and Sexual Minority Black Youth.

    Science.gov (United States)

    Gerke, Donald; Budd, Elizabeth L; Plax, Kathryn

    2016-01-01

    Black and lesbian, gay, bisexual, or questioning (LGBQ) youth in the United States are disproportionately affected by HIV and other sexually transmitted diseases (STDs). Although self-efficacy is strongly, positively associated with safer sex behaviors, no studies have examined the validity of a safer sex self-efficacy scale used by many federally funded HIV/STD prevention programs. This study aims to test factor validity of the Sexual Self-Efficacy Scale by using confirmatory factor analysis (CFA) to determine if scale validity varies between heterosexual and LGBQ Black youth. The study uses cross-sectional data collected through baseline surveys with 226 Black youth (15 to 24 years) enrolled in community-based HIV-prevention programs. Participants use a 4-point Likert-type scale to report their confidence in performing 6 healthy sexual behaviors. CFAs are conducted on 2 factor structures of the scale. Using the best-fitting model, the scale is tested for measurement invariance between the 2 groups. A single-factor model with correlated errors of condom-specific items fits the sample well and, when tested with the heterosexual group, the model demonstrates good fit. However, when tested with the LGBQ group, the same model yields poor fit, indicating factorial noninvariance between the groups. The Sexual Self-Efficacy Scale does not perform equally well among Black heterosexual and LGBQ youth. Study findings suggest additional research is needed to inform development of measures for safer sex self-efficacy among Black LGBQ youth to ensure validity of conceptual understanding and to accurately assess effectiveness of HIV/STD prevention interventions among this population.

  19. Comparison of Objectively Measured and Self-reported Time Spent Sitting

    DEFF Research Database (Denmark)

    Lagersted-Olsen, Julie; Korshøj, M; Skotte, J

    2014-01-01

    Until recently, methods for objective quantification of sitting time have been lacking. The aim of this study was to validate self-reported measures against objectively measured total sitting time and longest continuous time with uninterrupted sitting during working hours, leisure time on workday...... a retrospective 7-day questionnaire. A generalized linear model showed the difference between the methods. No significant correlations were found between objective and self-reported sitting time (r...

  20. Validation of the PROMIS® measures of self-efficacy for managing chronic conditions.

    Science.gov (United States)

    Gruber-Baldini, Ann L; Velozo, Craig; Romero, Sergio; Shulman, Lisa M

    2017-07-01

    The Patient-Reported Outcomes Measurement Information System ® (PROMIS ® ) was designed to develop, validate, and standardize item banks to measure key domains of physical, mental, and social health in chronic conditions. This paper reports the calibration and validation testing of the PROMIS Self-Efficacy for Managing Chronic Conditions measures. PROMIS Self-Efficacy for Managing Chronic Conditions item banks comprise five domains, Self-Efficacy for Managing: Daily Activities, Symptoms, Medications and Treatments, Emotions, and Social Interactions. Banks were calibrated in 1087 subjects from two data sources: 837 patients with chronic neurologic conditions (epilepsy, multiple sclerosis, neuropathy, Parkinson disease, and stroke) and 250 subjects from an online Internet sample of adults with general chronic conditions. Scores were compared with one legacy scale: Self-Efficacy for Managing Chronic Disease 6-Item scale (SEMCD6) and five PROMIS short forms: Global Health (Physical and Mental), Physical Function, Fatigue, Depression, and Anxiety. The sample was 57% female, mean age = 53.8 (SD = 14.7), 76% white, 21% African American, 6% Hispanic, and 76% with greater than high school education. Full-item banks were created for each domain. All measures had good internal consistency and correlated well with SEMCD6 (r  = 0.56-0.75). Significant correlations were seen between the Self-Efficacy measures and other PROMIS short forms (r  > 0.38). The newly developed PROMIS Self-Efficacy for Managing Chronic Conditions measures include five domains of self-efficacy that were calibrated across diverse chronic conditions and show good internal consistency and cross-sectional validity.

  1. The structure of post-traumatic stress disorder symptoms in three female trauma samples: A comparison of interview and self-report measures

    Science.gov (United States)

    Scher, Christine D.; McCreary, Donald R.; Asmundson, Gordon J.G.; Resick, Patricia A.

    2009-01-01

    Empirical research increasingly suggests that post-traumatic stress disorder (PTSD) is comprised of four factors: re-experiencing, avoidance, numbing, and hyperarousal. Nonetheless, there remains some inconsistency in the findings of factor analyses that form the bulk of this empirical literature. One source of such inconsistency may be assessment measure idiosyncrasies. To examine this issue, we conducted confirmatory factor analyses of interview and self-report data across three trauma samples. Analyses of the interview data indicated a good fit for a four-factor model across all samples; analyses of the self-report data indicated an adequate fit in two of three samples. Overall, findings suggest that measure idiosyncrasies may account for some of the inconsistency in previous factor analyses of PTSD symptoms. PMID:18206346

  2. Measurement of the form factor ratios in semileptonic decays of charm mesons

    International Nuclear Information System (INIS)

    R. Zaliznyak

    1999-01-01

    I have measured the form factor ratios r 2 = A 2 (0)/A 1 (0) and r V = V (0)/A 1 (0) in the semileptonic charm meson decay D + → (anti K) *0 e + ν e from data collected by the Fermilab E791 collaboration. Form factors are introduced in the calculation of the hadronic current in semileptonic decays of strange, charm, or bottom mesons, such as D + → (anti K) *0 e + ν e . Semileptonic decays provide insight into quark coupling to the W boson since the leptonic and hadronic amplitudes in the Feynman diagram for the decay are completely separate. There are no strong interactions between the final state leptons and quarks. A number of theoretical models predict the values of the form factors for D + → (anti K) *0 e + ν e , though there is a large range of predictions. E791 is a hadroproduction experiment that recorded over 20 billion interactions with a 500 GeV π - beam incident on five thin targets during the 1991-92 Fermilab fixed-target run. Approximately 3000 D + → (anti K) *0 e + ν e decays are fully reconstructed. In order to extract the form factor ratios from the data, I implement a multidimensional unbinned maximum likelihood fit with a large sample of simulated (Monte Carlo) D + → (anti K) *0 e + ν e events. The large E791 data sample provides the most precise measurement of the form factor ratios to date. The measured values for the form factor ratios are r 2 = 0.71 ± 0.08 ± 0.09 and r V = 1.84 ± 0.11 ± 0.08. These results are in good agreement with some Lattice Gauge calculations. However the agreement with quark model predictions is not as good

  3. Piers Harris and Coopersmith Measure of Self-Esteem: A Comparative Analysis

    Science.gov (United States)

    Lynch, Mervin D.; Foley-Peres, Kathleen D.; Sullivan, Stefanie S.

    2008-01-01

    The purposes of this study were to see if the items from the Piers Harris Self Concept Scale and the Coopersmith Self Esteem Inventory had construct and predictive validity. Items used in this study were 50 items from the Coopersmith Self-Esteem Inventory and 80 items from the Piers Harris Self-Concept Scale. Construct measures were obtained using…

  4. Concordance of self-report and measured height and weight of college students.

    Science.gov (United States)

    Quick, Virginia; Byrd-Bredbenner, Carol; Shoff, Suzanne; White, Adrienne A; Lohse, Barbara; Horacek, Tanya; Kattelmann, Kendra; Phillips, Beatrice; Hoerr, Sharon L; Greene, Geoffrey

    2015-01-01

    This study examined associations between college students' self-report and measured height and weight. Participants (N = 1,686) were 77% white, 62% female, aged 18-24 years (mean ± SD, 19.1 ± 1.1 years), and enrolled at 8 US universities. Body mass index (BMI) was calculated for self-report (via online survey); trained researchers measured height and weight and categorized them as normal (18.5 to obese (30 to obese (≥ 35). Concordance of self-report vs objectively measured BMI groups using chi-square revealed that 93% were accurate, 4% were underestimated, and 2.7% were overestimated. Pearson correlations and adjusted linear regression revealed significant associations between self-report and measured BMI (r = .97; P students. Copyright © 2015 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  5. Self-confidence and metacognitive processes

    Directory of Open Access Journals (Sweden)

    Kleitman Sabina

    2005-01-01

    Full Text Available This paper examines the status of Self-confidence trait. Two studies strongly suggest that Self-confidence is a component of metacognition. In the first study, participants (N=132 were administered measures of Self-concept, a newly devised Memory and Reasoning Competence Inventory (MARCI, and a Verbal Reasoning Test (VRT. The results indicate a significant relationship between confidence ratings on the VRT and the Reasoning component of MARCI. The second study (N=296 employed an extensive battery of cognitive tests and several metacognitive measures. Results indicate the presence of robust Self-confidence and Metacognitive Awareness factors, and a significant correlation between them. Self-confidence taps not only processes linked to performance on items that have correct answers, but also beliefs about events that may never occur.

  6. Reliable blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, C. H.; Rasmussen, Niels H

    2014-01-01

    Background: Patients often fail to adhere to clinical recommendations when using current blood pressure self-measurement (BPSM) methods and equipment. As existing BPSM equipment is not able to detect non-adherent behavior, this could result in misdiagnosis and treatment error. To overcome...... patients scheduled for self-measuring their blood pressure (BP) in the waiting room at an obstetrics department's outpatient clinic to perform an additional BPSM using ValidAid. We then compared the automatically measured and classified values from ValidAid with our manual observations. Results: We found...

  7. Body Dissatisfaction Measured with a Figure Preference Task and Self-Esteem in 8 Year Old Children—a Study within the ABIS-Project

    Directory of Open Access Journals (Sweden)

    F.S. Koch

    2008-01-01

    Full Text Available Body dissatisfaction has been related to low self-esteem and depression in adolescents. With regard to the current world wide rise in childhood obesity and common stigmatization of adults and children with obesity, easy to use and cost effective measurements of body dissatisfaction would be helpful in epidemiological research. In the current study, detailed data on body measurements with regard to perceived and ideal body size and body dissatisfaction, as measured with the figure preference task, are presented for a population based sample of 3837 children. Perceived body size correlations to weight, body mass index [BMI], and waist circumference were between 0.41 and 0.54; and to height between 0.12 and 0.21. Odds ratios for lower self-esteem increased with increase in body dissatisfaction. Gender differences in body dissatisfaction were present but not found in relation to self-esteem. It is concluded that the figure preference task yields valuable information in epidemiological studies of children as young as 7.5 years of age. It is argued, that the figure preference task is an additional measurement which theoretically relates to psychological stress in childhood.

  8. Body Dissatisfaction Measured with a Figure Preference Task and Self-Esteem in 8 Year Old Children - a Study within the ABIS-Project

    Directory of Open Access Journals (Sweden)

    A. Sepa

    2008-01-01

    Full Text Available Body dissatisfaction has been related to low self-esteem and depression in adolescents. With regard to the current world wide rise in childhood obesity and common stigmatization of adults and children with obesity, easy to use and cost effective measurements of body dissatisfaction would be helpful in epidemiological research. In the current study, detailed data on body measurements with regard to perceived and ideal body size and body dissatisfaction, as measured with the figure preference task, are presented for a population based sample of 3837 children. Perceived body size correlations to weight, body mass index [BMI], and waist circumference were between 0.41 and 0.54; and to height between 0.12 and 0.21. Odds ratios for lower self-esteem increased with increase in body dissatisfaction. Gender differences in body dissatisfaction were present but not found in relation to self-esteem. It is concluded that the figure preference task yields valuable information in epidemiological studies of children as young as 7.5 years of age. It is argued, that the figure preference task is an additional measurement which theoretically relates to psychological stress in childhood.

  9. Cued Retrospective Reporting: Measuring Self-Regulated Learning

    NARCIS (Netherlands)

    Van Meeuwen, Ludo; Brand-Gruwel, Saskia; Kirschner, Paul A.; De Bock, Jeano; Van Merriënboer, Jeroen

    2012-01-01

    Van Meeuwen, L. W., Brand-Gruwel, S., Kirschner, P. A., De Bock, J. J. P. R., & Van Merriënboer, J. J. G. (2012, april). Cued retrospective reporting: Measuring self-regulated learning. Paper presented at the AERA annual meeting, Vancouver, B. C.

  10. Optimising neutron polarizers--measuring the flipping ratio and related quantities

    CERN Document Server

    Goossens, D J

    2002-01-01

    The continuing development of gaseous spin polarized sup 3 He transmission filters for use as neutron polarizers makes the choice of optimum thickness for these filters an important consideration. The 'quality factors' derived for the optimisation of transmission filters for particular measurements are general to all neutron polarizers. In this work optimisation conditions for neutron polarizers are derived and discussed for the family of studies related to measuring the flipping ratio from samples. The application of the optimisation conditions to sup 3 He transmission filters and other types of neutron polarizers is discussed. Absolute comparisons are made between the effectiveness of different types of polarizers for this sort of work.

  11. The Internet Self-Perception Scale: Measuring Elementary Students' Levels of Self-Efficacy regarding Internet Use

    Science.gov (United States)

    Hinson, Janice; DiStefano, Christine; Daniel, Cathy

    2003-01-01

    This study investigated fourth grade students' perceptions of abilities to use the Internet. The 31-item research instrument measuring Internet Self-Perceptions was adapted for use from the Reader Self-Perception Scale (RSPS) developed by Henk and Melnick (1995). The RSPS survey was based upon Bandura's (1977, 1986, 1995) research in the areas of…

  12. Change in Self-Efficacy as a Measure of Training Effectiveness at Squadron Officer School.

    Science.gov (United States)

    1992-09-01

    Note: Low scores indicate high self-efficacy SExt Sat E Sat ---X-- No Opin -0 Dissat • Ext Dissat Figure O.10.b Profile Plot for TALJOB 0-46...efficacy SExt Sat - Sat --X No Opin -& Dissat Ext Dissat Figure O.10.c Profile Plot for TALJOB 0-47 Communication Skills SATISFACTION WITH TALENT USE...PRE-TEST) Mean 35 Low Self-Efficacy 30 - 25l 20 ... . . 15 High Self-Efficacy 10 Before After Note: Low scores indicate high self-efficacy SExt Sat E

  13. Self-body recognition depends on implicit and explicit self-esteem.

    Science.gov (United States)

    Richetin, Juliette; Xaiz, Annalisa; Maravita, Angelo; Perugini, Marco

    2012-03-01

    The present contribution bridges research on body image, self-esteem, and body recognition. Recent work in neuroscience indicates a superiority in the processing of self relative to others' body parts. The present contribution shows that this ability is not universal but it is qualified by individual differences in implicit and explicit self-esteem. In fact, two studies (n₁ = 41 and n₂ = 35) using two different paradigms in body recognition and direct and indirect measures of self-esteem reveal that this advantage in recognizing one's own body parts is associated with one's level of self-esteem. Moreover, it appears that measures of implicit and explicit self-esteem provide different contributions to self-body recognition abilities and that these contributions depend on how self-body recognition is assessed. Implications of these results are discussed notably in the perspective of research on body image. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Amphibious hearing in ringed seals (Pusa hispida): underwater audiograms, aerial audiograms and critical ratio measurements.

    Science.gov (United States)

    Sills, Jillian M; Southall, Brandon L; Reichmuth, Colleen

    2015-07-01

    Ringed seals (Pusa hispida) are semi-aquatic marine mammals with a circumpolar Arctic distribution. In this study, we investigate the amphibious hearing capabilities of ringed seals to provide auditory profiles for this species across the full range of hearing. Using psychophysical methods with two trained ringed seals, detection thresholds for narrowband signals were measured under quiet, carefully controlled environmental conditions to generate aerial and underwater audiograms. Masked underwater thresholds were measured in the presence of octave-band noise to determine critical ratios. Results indicate that ringed seals possess hearing abilities comparable to those of spotted seals (Phoca largha) and harbor seals (Phoca vitulina), and considerably better than previously reported for ringed and harp seals. Best sensitivity was 49 dB re. 1 µPa (12.8 kHz) in water, and -12 dB re. 20 µPa (4.5 kHz) in air, rivaling the acute hearing abilities of some fully aquatic and terrestrial species in their respective media. Critical ratio measurements ranged from 14 dB at 0.1 kHz to 31 dB at 25.6 kHz, suggesting that ringed seals--like other true seals--can efficiently extract signals from background noise across a broad range of frequencies. The work described herein extends similar research on amphibious hearing in spotted seals recently published by the authors. These parallel studies enhance our knowledge of the auditory capabilities of ice-living seals, and inform effective management strategies for these and related species in a rapidly changing Arctic environment. © 2015. Published by The Company of Biologists Ltd.

  15. The measurement of mass spectrometric peak height ratio of helium isotope in trace samples

    International Nuclear Information System (INIS)

    Sun Mingliang

    1989-01-01

    An experiment study on the measurement of mass spectrometric peak height ratio of helium isotope in the trace gaseous sample is discussed by using the gas purification line designed by the authors and model VG-5400 static-vacuum noble gas mass spectrometer imported and air helium as a standard. The results show that the amount of He and Ne in natural gas sample is 99% after purification. When the amount of He in Mass Spectrometer is more than 4 x 10 -7 cm 3 STP, it's sensitivity remains stable, about 10 -4 A/cm 3 STP He and the precision of 3 He/ 4 He ratio within the following 17 days is 1.32%. The 'ABA' pattern and experiment condition in the measurement of mass spectrometric peak height ratio of He isotope are presented

  16. Neutron spectrometer for DD/DT burning ratio measurement in fusion experimental reactor

    International Nuclear Information System (INIS)

    Asai, Keisuke; Naoi, Norihiro; Iguchi, Tetsuo; Watanabe, Kenichi; Kawarabayashi, Jun; Nishitani, Takeo

    2006-01-01

    The most feasible fuels for a fusion reactor are D (Deuterium) and T (Tritium). DD and/or DT fusion reaction or nuclear burning reaction provides two kinds of neutrons, DD neutron and DT neutron, respectively. DD/DT burning ratio, which can be estimated by DD/DT neutron ratio in the burning plasma, is essential for burn control, alpha particle emission rate monitoring and tritium fuel cycle estimation. Here we propose a new neutron spectrometer for the absolute DD/DT burning ratio measurement. The system consists of a Proton Recoil Telescope (PRT) and a Time-of-Flight (TOF) technique. We have conducted preliminary experiments with a prototype detector and a DT neutron beam (φ20 mm) at the Fusion Neutronics Source, Japan Atomic Energy Agency (JAEA), to assess its basic performance. The detection efficiency obtained by the experiment is consistent with the calculation results in PRT, and sufficient energy resolution for the DD/DT neutron discrimination has been achieved in PRT and TOF. The validity of the Monte Carlo calculation has also been confirmed by comparing the experimental results with the calculation results. The design consideration of this system for use in ITER (International Thermonuclear Experimental Reactor) has shown that this system is capable of monitoring the line-integrated DD/DT burning ratio for the plasma core line of sight with the required measurement accuracy of 20% in the upper 4 decades of the ITER operation (fusion power: 100 kW-700 MW). (author)

  17. Scaling laws and indications of self-organized criticality in urban systems

    International Nuclear Information System (INIS)

    Chen Yanguang; Zhou Yixing

    2008-01-01

    Evolution of urban systems has been considered to exhibit some form of self-organized criticality (SOC) in the literature. This paper provides further mathematical foundations and empirical evidences to support the supposition. The hierarchical structure of systems of cities can be formulated as three exponential functions: the number law, the population size law, and the area law. These laws are identical in form to the Horton-Strahler laws of rivers and Gutenberg-Richter laws of earthquakes. From the exponential functions, three indications of SOC are also derived: the frequency-spectrum relation indicting the 1/f noise, the power laws indicating the fractal structure, and the Zipf's law indicating the rank-size distribution. These mathematical models form a set of scaling laws for urban systems, as demonstrated in the empirical study of the system of cities in China. The fact that the scaling laws of urban systems bear an analogy to those on rivers and earthquakes lends further support to the notion of possible SOC in urban systems

  18. Change in self-reported health status among immigrants in the United States: associations with measures of acculturation.

    Science.gov (United States)

    Lee, Sunmin; O'Neill, Allison H; Ihara, Emily S; Chae, David H

    2013-01-01

    Although acculturation may have positive effects for immigrants, including better socioeconomic profiles and increased occupational opportunities, their health profiles deteriorate with longer duration in the U.S. Prior research indicates that increasing acculturation is associated with some poorer health outcomes among immigrants in the U.S. However, most of these studies have used length of stay or English language proficiency as proxies for acculturation, and have mainly examined self-reported "current" health outcomes. This study advances knowledge on associations between acculturation and health among immigrants by explicitly examining self-reported "change" in health since immigration, in relation to acculturation-related variables. We use data from the New Immigrant Survey (NIS; 2003-2004), a cross-sectional study of legal immigrants to the U.S. In addition to testing more conventionally examined proxies of acculturation (length of stay and English proficiency), we also examine English language use and self-reported change in diet. Multivariable logistic regression analyses on 5,982 participants generally supported previous literature indicating a deleterious impact of acculturation, with increasing duration of stay and greater self-reported change in diet being associated with a poorer change in health since moving to the U.S. Although English language proficiency and use were associated with greater odds of reporting a worse change in health when examined individually, they were non-significant in multivariable models including all acculturation measures. Findings from this study suggest that when taking into account multiple measures of acculturation, language may not necessarily indicate unhealthy assimilation and dietary change may be a pathway leading to declines in immigrant health. Increasing duration in the U.S. may also reflect the adoption of unhealthy behaviors, as well as greater exposure to harmful sources of psychosocial stress including

  19. Change in self-reported health status among immigrants in the United States: associations with measures of acculturation.

    Directory of Open Access Journals (Sweden)

    Sunmin Lee

    Full Text Available Although acculturation may have positive effects for immigrants, including better socioeconomic profiles and increased occupational opportunities, their health profiles deteriorate with longer duration in the U.S. Prior research indicates that increasing acculturation is associated with some poorer health outcomes among immigrants in the U.S. However, most of these studies have used length of stay or English language proficiency as proxies for acculturation, and have mainly examined self-reported "current" health outcomes. This study advances knowledge on associations between acculturation and health among immigrants by explicitly examining self-reported "change" in health since immigration, in relation to acculturation-related variables. We use data from the New Immigrant Survey (NIS; 2003-2004, a cross-sectional study of legal immigrants to the U.S. In addition to testing more conventionally examined proxies of acculturation (length of stay and English proficiency, we also examine English language use and self-reported change in diet. Multivariable logistic regression analyses on 5,982 participants generally supported previous literature indicating a deleterious impact of acculturation, with increasing duration of stay and greater self-reported change in diet being associated with a poorer change in health since moving to the U.S. Although English language proficiency and use were associated with greater odds of reporting a worse change in health when examined individually, they were non-significant in multivariable models including all acculturation measures. Findings from this study suggest that when taking into account multiple measures of acculturation, language may not necessarily indicate unhealthy assimilation and dietary change may be a pathway leading to declines in immigrant health. Increasing duration in the U.S. may also reflect the adoption of unhealthy behaviors, as well as greater exposure to harmful sources of psychosocial

  20. Quantitative stress measurement of elastic deformation using mechanoluminescent sensor: An intensity ratio model

    Science.gov (United States)

    Cai, Tao; Guo, Songtao; Li, Yongzeng; Peng, Di; Zhao, Xiaofeng; Liu, Yingzheng

    2018-04-01

    The mechanoluminescent (ML) sensor is a newly developed non-invasive technique for stress/strain measurement. However, its application has been mostly restricted to qualitative measurement due to the lack of a well-defined relationship between ML intensity and stress. To achieve accurate stress measurement, an intensity ratio model was proposed in this study to establish a quantitative relationship between the stress condition and its ML intensity in elastic deformation. To verify the proposed model, experiments were carried out on a ML measurement system using resin samples mixed with the sensor material SrAl2O4:Eu2+, Dy3+. The ML intensity ratio was found to be dependent on the applied stress and strain rate, and the relationship acquired from the experimental results agreed well with the proposed model. The current study provided a physical explanation for the relationship between ML intensity and its stress condition. The proposed model was applicable in various SrAl2O4:Eu2+, Dy3+-based ML measurement in elastic deformation, and could provide a useful reference for quantitative stress measurement using the ML sensor in general.

  1. Measuring the Self-Stigma Associated with Seeking Psychological Help

    Science.gov (United States)

    Vogel, David L.; Wade, Nathaniel G.; Haake, Shawn

    2006-01-01

    Self-stigma is an important factor in people's decisions not to engage in therapy. To measure this construct, the authors developed the 10-item Self-Stigma of Seeking Help (SSOSH) scale. In Study 1 (n = 583), the SSOSH had a unidimensional factor structure and good reliability (0.91) among participants. Study 2 (n = 470) confirmed the factor…

  2. Generalized weighted ratio method for accurate turbidity measurement over a wide range.

    Science.gov (United States)

    Liu, Hongbo; Yang, Ping; Song, Hong; Guo, Yilu; Zhan, Shuyue; Huang, Hui; Wang, Hangzhou; Tao, Bangyi; Mu, Quanquan; Xu, Jing; Li, Dejun; Chen, Ying

    2015-12-14

    Turbidity measurement is important for water quality assessment, food safety, medicine, ocean monitoring, etc. In this paper, a method that accurately estimates the turbidity over a wide range is proposed, where the turbidity of the sample is represented as a weighted ratio of the scattered light intensities at a series of angles. An improvement in the accuracy is achieved by expanding the structure of the ratio function, thus adding more flexibility to the turbidity-intensity fitting. Experiments have been carried out with an 850 nm laser and a power meter fixed on a turntable to measure the light intensity at different angles. The results show that the relative estimation error of the proposed method is 0.58% on average for a four-angle intensity combination for all test samples with a turbidity ranging from 160 NTU to 4000 NTU.

  3. Measurement of the cosmic ray muon charge ratio with the OPERA detector

    OpenAIRE

    Mauri, N; Siol, M

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the cosmic ray muon charge ratio Rμ = Nμ+/Nμ− in the TeV energy region. We analyzed 403069 cosmic ray muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the Rμ dependence on the primary composition. Rμ is also sho...

  4. High-precision branching-ratio measurement for the superallowed β+ emitter 26Alm

    Science.gov (United States)

    Finlay, P.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Bandyopadhyay, D.; Cross, D. S.; Demand, G.; Djongolov, M.; Ettenauer, S.; Garrett, P. E.; Green, K. L.; Grinyer, G. F.; Hackman, G.; Leach, K. G.; Pearson, C. J.; Phillips, A. A.; Rand, E. T.; Sumithrarachchi, C. S.; Triambak, S.; Williams, S. J.

    2012-05-01

    A high-precision branching-ratio measurement for the superallowed β+ emitter 26Alm was performed at the TRIUMF-ISAC radioactive ion beam facility. An upper limit of ⩽12 ppm at 90% confidence level was found for the second forbidden β+ decay of 26Alm to the 21+ state at 1809 keV in 26Mg. An inclusive upper limit of ⩽15 ppm at 90% confidence level was found when considering all possible nonanalog β+/EC decay branches of 26Alm, resulting in a superallowed branching ratio of 100.0000-0.0015+0%.

  5. Measuring the Self-Esteem of Adolescents with Mental Health Problems: Theory Meets Practice.

    Science.gov (United States)

    Willoughby, Colleen; Polatajko, Helene; Currado, Catherine; Harris, Kathryn; King, Gillian

    2000-01-01

    Comparison of the self-esteem of 39 adolescents with mental health problems to that of a normative sample for the Self-Perception Profile for Adolescents. Results indicate no difference between the two groups' self-esteem following participation in a prevocational program. Dimensions of self-concept that are most important to the adolescent will…

  6. The Moral Self-Image Scale: Measuring and Understanding the Malleability of the Moral Self.

    Science.gov (United States)

    Jordan, Jennifer; Leliveld, Marijke C; Tenbrunsel, Ann E

    2015-01-01

    Recent ethical decision-making models suggest that individuals' own view of their morality is malleable rather than static, responding to their (im)moral actions and reflections about the world around them. Yet no construct currently exists to represent the malleable state of a person's moral self-image (MSI). In this investigation, we define this construct, as well as develop a scale to measure it. Across five studies, we show that feedback about the moral self alters an individual's MSI as measured by our scale. We also find that the MSI is related to, but distinct from, related constructs, including moral identity, self-esteem, and moral disengagement. In Study 1, we administered the MSI scale and several other relevant scales to demonstrate convergent and discriminant validity. In Study 2, we examine the relationship between the MSI and one's ought versus ideal self. In Studies 3 and 4, we find that one's MSI is affected in the predicted directions by manipulated feedback about the moral self, including feedback related to social comparisons of moral behavior (Study 3) and feedback relative to one's own moral ideal (Study 4). Lastly, Study 5 provides evidence that the recall of one's moral or immoral behavior alters people's MSI in the predicted directions. Taken together, these studies suggest that the MSI is malleable and responds to individuals' moral and immoral actions in the outside world. As such, the MSI is an important variable to consider in the study of moral and immoral behavior.

  7. Why self-controlled feedback enhances motor learning: Answers from electroencephalography and indices of motivation.

    Science.gov (United States)

    Grand, Kirk F; Bruzi, Alessandro T; Dyke, Ford B; Godwin, Maurice M; Leiker, Amber M; Thompson, Andrew G; Buchanan, Taylor L; Miller, Matthew W

    2015-10-01

    It was tested whether learners who choose when to receive augmented feedback while practicing a motor skill exhibit enhanced augmented feedback processing and intrinsic motivation, along with superior learning, relative to learners who do not control their feedback. Accordingly, participants were assigned to either self-control (Self) or yoked groups and asked to practice a non-dominant arm beanbag toss. Self participants received augmented feedback at their discretion, whereas Yoked participants were given feedback schedules matched to Self counterparts. Participants' visual feedback was occluded, and when they received augmented feedback, their processing of it was indexed with the electroencephalography-derived feedback-related negativity (FRN). Participants self-reported intrinsic motivation via the Intrinsic Motivation Inventory (IMI) after practice, and completed a retention and transfer test the next day to index learning. Results partially support the hypothesis. Specifically, Self participants reported higher IMI scores, exhibited larger FRNs, and demonstrated better accuracy on the transfer test, but not on the retention test, nor did they exhibit greater consistency on the retention or transfer tests. Additionally, post-hoc multiple regression analysis indicated FRN amplitude predicted transfer test accuracy (accounting for IMI score). Results suggest self-controlled feedback schedules enhance feedback processing, which enhances the transfer of a newly acquired motor skill. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Can T1 w/T2 w ratio be used as a myelin-specific measure in subcortical structures? Comparisons between FSE-based T1 w/T2 w ratios, GRASE-based T1 w/T2 w ratios and multi-echo GRASE-based myelin water fractions.

    Science.gov (United States)

    Uddin, Md Nasir; Figley, Teresa D; Marrie, Ruth Ann; Figley, Chase R

    2018-03-01

    Given the growing popularity of T 1 -weighted/T 2 -weighted (T 1 w/T 2 w) ratio measurements, the objective of the current study was to evaluate the concordance between T 1 w/T 2 w ratios obtained using conventional fast spin echo (FSE) versus combined gradient and spin echo (GRASE) sequences for T 2 w image acquisition, and to compare the resulting T 1 w/T 2 w ratios with histologically validated myelin water fraction (MWF) measurements in several subcortical brain structures. In order to compare these measurements across a relatively wide range of myelin concentrations, whole-brain T 1 w magnetization prepared rapid acquisition gradient echo (MPRAGE), T 2 w FSE and three-dimensional multi-echo GRASE data were acquired from 10 participants with multiple sclerosis at 3 T. Then, after high-dimensional, non-linear warping, region of interest (ROI) analyses were performed to compare T 1 w/T 2 w ratios and MWF estimates (across participants and brain regions) in 11 bilateral white matter (WM) and four bilateral subcortical grey matter (SGM) structures extracted from the JHU_MNI_SS 'Eve' atlas. Although the GRASE sequence systematically underestimated T 1 w/T 2 w values compared to the FSE sequence (revealed by Bland-Altman and mountain plots), linear regressions across participants and ROIs revealed consistently high correlations between the two methods (r 2 = 0.62 for all ROIs, r 2 = 0.62 for WM structures and r 2 = 0.73 for SGM structures). However, correlations between either FSE-based or GRASE-based T 1 w/T 2 w ratios and MWFs were extremely low in WM structures (FSE-based, r 2 = 0.000020; GRASE-based, r 2 = 0.0014), low across all ROIs (FSE-based, r 2 = 0.053; GRASE-based, r 2 = 0.029) and moderate in SGM structures (FSE-based, r 2 = 0.20; GRASE-based, r 2 = 0.17). Overall, our findings indicated a high degree of correlation (but not equivalence) between FSE-based and GRASE-based T 1 w/T 2 w ratios, and low correlations between T 1 w/T 2 w ratios and MWFs. This

  9. Measurement and Enhancement of Plasticity Indices of some ...

    African Journals Online (AJOL)

    Experimental procedures were followed and one basic modification was made to Worrall and Khan measurement of rate of flow of plastic clays in order to prevent sud-den rush of compressed air. Results indicate that plasticity brought about by ageing can be measured for clays in aqueous and organic medium. Clays aged ...

  10. Measurement of the fission ratio for several configurations of uranium oxide rod clusters

    International Nuclear Information System (INIS)

    Pattenden, S.K.; Patterson, C.R.

    1962-02-01

    This report describes measurements of the fission ratio for a single fuel channel of oxide rod clusters in an essentially infinite block of graphite. The measurements were made using the 'catcher-foil' technique, the activities of the catcher foils being measured by β-counting. Results are given, for 37-rod; 18-rod; 7-rod and 3-rod clusters, and are compared with theoretical predictions. (author)

  11. Mars Atmospheric Escape Recorded by H, C and O Isotope Ratios in Carbon Dioxide and Water Measured by the Sam Tunable Laser Spectrometer on the Curiosity Rover

    Science.gov (United States)

    Webster, C. R.; Mahaffy, P. R.; Leshin, L. A.; Atreya, S. K.; Flesch, G. J.; Stern, J.; Christensen, L. E.; Vasavada, A. R.; Owen, T.; Niles, P. B.; hide

    2013-01-01

    Stable isotope ratios in C, H, N, O and S are powerful indicators of a wide variety of planetary geophysical processes that can identify origin, transport, temperature history, radiation exposure, atmospheric escape, environmental habitability and biological activity [2]. For Mars, measurements to date have indicated enrichment in all the heavier isotopes consistent with atmospheric escape processes, but with uncertainty too high to tie the results with the more precise isotopic ratios achieved from SNC meteoritic analyses. We will present results to date of H, C and O isotope ratios in CO2 and H2O made to high precision (few per mil) using the Tunable Laser Spectrometer (TLS) that is part of the Sample Analysis at Mars (SAM) instrument suite on MSL s Curiosity Rover.

  12. Study on the dynamic behavior of a current in cable-in-conduit conductors by using self magnetic field measurements

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292, Gifu (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Imagawa, Shinsaku; Mito, Toshiyuki [National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292, Gifu (Japan); Kizu, Kaname; Murakami, Haruyuki; Yoshida, Kiyoshi [Japan Atomic Energy Agency, Ibaraki (Japan)

    2011-10-15

    In order to understand the current behavior inside a cable-in-conduit conductor (CICC), self magnetic field measurements on the CICC were conducted. A prototype NbTi CICC, the configuration of which is a racket shape, for JT-60SA EF coil was used as a short conductor sample. By using Hall sensors arranged around the short conductor sample, the variation in the self magnetic field was measured. Taking into account the measurements, the current behavior inside the CICC was analyzed by using analytical models consisting of line currents. The analytical results indicate that the current distribution in the cross-section of the CICC would be non-uniform before a normal propagation, and the current distribution would be improved after the normal propagation.

  13. Validation of the self regulation questionnaire as a measure of health in quality of life research

    Directory of Open Access Journals (Sweden)

    Büssing A

    2009-05-01

    Full Text Available Abstract Objectives Several epidemiological studies address psychosomatic 'self regulation' as a measure of quality of life aspects. However, although widely used in studies with a focus on complementary cancer treatment, and recognized to be associated with better survival of cancer patients, it is unclear what the 'self regulation' questionnaire exactly measures. Design and setting In a sample of 444 individuals (27% healthy, 33% cancer, 40% other internal diseases, we performed reliability and exploratory factor analyses, and correlated the 16-item instrument with external measures such as the Hospital Anxiety and Depression Scale, the Herdecke Quality of Life questionnaire, and autonomic regulation questionnaire. Results The 16-item pool had a very good internal consistency (Cronbach's alpha = 0.948 and satisfying/good (rrt = 0.796 test-retest reliability after 3 months. Exploratory factor analysis indicated 2 sub-constructs: (1 Ability to change behaviour in order to reach goals, and (2 Achieve satisfaction and well-being. Both sub-scales correlated well with quality of life aspects, particularly with Initiative Power/Interest, Social Interactions, Mental Balance, and negatively with anxiety and depression. Conclusions The Self Regulation Questionnaire (SRQ was found to be a valid and reliable tool which measures unique psychosomatic abilities. Self regulation deals with competence and autonomy and can be regarded as a problem solving capacity in terms of an active adaptation to stressful situations to restore wellbeing. The tool is an interesting option to be used particularly in complementary medicine research with a focus on behavioural modification.

  14. Development of a scale to measure adherence to self-monitoring of blood glucose with latent variable measurement.

    Science.gov (United States)

    Wagner, J A; Schnoll, R A; Gipson, M T

    1998-07-01

    Adherence to self-monitoring of blood glucose (SMBG) is problematic for many people with diabetes. Self-reports of adherence have been found to be unreliable, and existing paper-and-pencil measures have limitations. This study developed a brief measure of SMBG adherence with good psychometric properties and a useful factor structure that can be used in research and in practice. A total of 216 adults with diabetes responded to 30 items rated on a 9-point Likert scale that asked about blood monitoring habits. In part I of the study, items were evaluated and retained based on their psychometric properties. The sample was divided into exploratory and confirmatory halves. Using the exploratory half, items with acceptable psychometric properties were subjected to a principal components analysis. In part II of the study, structural equation modeling was used to confirm the component solution with the entire sample. Structural modeling was also used to test the relationship between these components. It was hypothesized that the scale would produce four correlated factors. Principal components analysis suggested a two-component solution, and confirmatory factor analysis confirmed this solution. The first factor measures the degree to which patients rely on others to help them test and thus was named "social influence." The second component measures the degree to which patients use physical symptoms of blood glucose levels to help them test and thus was named "physical influence." Results of the structural model show that the components are correlated and make up the higher-order latent variable adherence. The resulting 15-item scale provides a short, reliable way to assess patient adherence to SMBG. Despite the existence of several aspects of adherence, this study indicates that the construct consists of only two components. This scale is an improvement on previous measures of adherence because of its good psychometric properties, its interpretable factor structure, and its

  15. Measurement of the cosmic ray muon charge ratio with the OPERA detector

    CERN Document Server

    Mauri, N

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the cosmic ray muon charge ratio Rμ = Nμ+/Nμ− in the TeV energy region. We analyzed 403069 cosmic ray muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the Rμ dependence on the primary composition. Rμ is also shown as a function of the Òvertical surface energyÓ Eμ cos !. A Þt to a simpliÞed model of muon pro- duction in atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.

  16. Split thickness skin graft meshing ratio indications and common practices.

    Science.gov (United States)

    Pripotnev, Stahs; Papp, Anthony

    2017-12-01

    Split thickness skin grafting is a commonly used technique in burn surgery for resurfacing wounds that are unlikely to heal without scarring. Meshing and expanding skin grafts allow for reconstruction of larger wounds with smaller donor sites. A retrospective chart review was performed of 210 patients with burns equal to or greater than 20% total body surface area admitted to Vancouver General Hospital between 1998 and 2014. Charts were reviewed to collect data on patient and burn demographics. A survey was sent to Canadian plastic surgeons registered with the CSPS to collect data on common practices in burn surgery nationwide. The patients that received 3:1 or higher meshed grafts were all flame burns, had a significantly higher average TBSA (51.89%±14.87 vs 29.13%±9.48, p=0.001), and a significantly higher full thickness burn TBSA (25.76%±21.97 vs 6.20%±9.04, p=0.001). We found no significant differences in gender, age, or burn location between the less than 2:1 and 3:1 or greater meshing ratio groups. The survey of plastic surgeons performing burn surgery in Canada revealed that 60% of responders had experience with skin grafts using meshing ratios of 3:1 or higher. Of these surgeons, 100% felt that burn size and 36% felt that burn location would influence their decision to use a 3:1 or higher meshing ratio. A larger burn size is the major influencing factor for the use of higher skin graft meshing ratios by Canadian burn surgeons. Furthermore, burn location determines the choice of donor and recipient sites in these cases. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  17. Relationship between self-reported adherence, antiretroviral drug concentration measurement and self-reported symptoms in patients treated for HIV-1 infection.

    Science.gov (United States)

    Fabbiani, Massimiliano; Di Giambenedetto, Simona; Cingolani, Antonella; Fanti, Iuri; Colafigli, Manuela; Tamburrini, Enrica; Cauda, Roberto; Navarra, Pierluigi; De Luca, Andrea; Murri, Rita

    2016-01-01

    The aim of the study was to explore relationships between self-reported adherence, antiretroviral drug concentration measurement (TDM) and self-reported symptoms. We systematically administered to human immunodeficiency (HIV)-infected outpatients a questionnaire evaluating measures of self-reported adherence (missing doses during last week, deviations from the prescribed timing of therapy, self-initiated discontinuations for > 24 or 48 h, exhausting drugs and present sense of how patients are taking therapy) and a panel of referred symptoms (a symptom score was built summing self-reported scores for each listed symptom). We selected patients who completed the questionnaire and also had a TDM (mainly reflecting adherence in the past few days or weeks), thus comparing these two tools as measures of adherence. A total of 130 patients (64.6% males, median age 44 years, 76.2% with HIV RNA HIV RNA symptom score was associated with a lower self-reported adherence and with a higher proportion of undetectable drug levels. Self-reported adherence and TDM showed a correlation and seemed to be comparable tools for adherence estimation. Self-reported symptoms were associated with lower adherence and undetectable drug levels.

  18. Understanding the natural and social factors behind regional longevity in Guangxi, China—Is centenarian ratio a good enough indicator for assessing the longevity level?

    Science.gov (United States)

    Deng, Q.; Wei, Y.; Zhao, Y.

    2017-12-01

    Despite a number of longevity indicators having been used in previous longevity studies, few studies have critically evaluated whether these indicators are suitable. In addition, an increasing number of studies have attempted to determine the influence of socio-economic and natural factors on regional longevity, but only certain factors were considered. The present study bridges this gap by determining the relationship between the seven longevity indicators and selecting 24 natural and socio-economic indicators in the 91 selected counties and districts in Guangxi, China. The seven longevity indicators here refer to Centenarian ratio, Longevity index, Longevity level, Aging tendency, 80+ ratio, 90+ ratio and 95+ ratio. Natural indicators in this study mainly refer to climatic ones. Socio-economic indicators can be categorized into those related to economic, education, local infrastructure, and health care facilities. These data were mainly drawn from the Meteorological Data Sharing Service System and Guangxi's sixth population census. Stepwise regression analysis has been used as the primary research method to determine the relationship between the longevity indicators and the natural, social, and economic indicators. The results show that the climate factors regarding atmospheric pressure, humidity, and rainfall are the most significant contributors to the longevity of the 60- to 90-year-old elderly in Guangxi, while the difference of mean annual temperature could have negative impacts. Also, the natural and socioeconomic factors that impact the extremely old population (those over 95 years old) in Guangxi are still not clear. This study reveals that the longevity index and longevity level are useful supplementary indexes to the centenarian ratio for assessing the regional longevity as they could help reflect the regional longevity regarding the proportion of young-old and old-old population and not just limit to those over 100 years old. The elderly (those from 60

  19. Influence of accommodative lag upon the far-gradient measurement of accommodative convergence to accommodation ratio in strabismic patients.

    Science.gov (United States)

    Miyata, Manabu; Hasebe, Satoshi; Ohtsuki, Hiroshi

    2006-01-01

    To determine the influence of the lag of accommodation (LOA) on the accommodative convergence to accommodation (AC/A) ratio measured by the far-gradient method in strabismic patients. The AC/A ratio was measured with a distance target viewed with and without -3.00 diopter (D) addition lenses in 63 patients with different types of strabismus (age range, 7-34 years; range of strabismic angle, -60 to +40 prism diopters; refractive error range, -7.33 to +6.63 D). The LOA for the same lens was measured with an open-view-type autorefractometer. The stimulus AC/A ratio and the AC/A ratio adjusted by the individually measured LOA (adjusted AC/A ratio) were compared. The mean +/- SD of the LOA to the -3.00 D lenses was 1.06 +/- 0.43 D. The mean adjusted AC/A ratio was 41% greater than the stimulus AC/A ratio. The LOA differed widely among patients (0.13 to 2.14 D), and a large LOA tended to appear in myopic or young patients. The AC/A ratio obtained using the conventional far-gradient method is significantly biased by the LOA, and thus does not always represent the actual relationship between accommodation and vergence control systems. Copyright Japanese Ophthalmological Society 2006.

  20. Measuring students' self-regulated learning in professional education: bridging the gap between event and aptitude measurements.

    Science.gov (United States)

    Endedijk, Maaike D; Brekelmans, Mieke; Sleegers, Peter; Vermunt, Jan D

    Self-regulated learning has benefits for students' academic performance in school, but also for expertise development during their professional career. This study examined the validity of an instrument to measure student teachers' regulation of their learning to teach across multiple and different kinds of learning events in the context of a postgraduate professional teacher education programme. Based on an analysis of the literature, we developed a log with structured questions that could be used as a multiple-event instrument to determine the quality of student teachers' regulation of learning by combining data from multiple learning experiences. The findings showed that this structured version of the instrument measured student teachers' regulation of their learning in a valid and reliable way. Furthermore, with the aid of the Structured Learning Report individual differences in student teachers' regulation of learning could be discerned. Together the findings indicate that a multiple-event instrument can be used to measure regulation of learning in multiple contexts for various learning experiences at the same time, without the necessity of relying on students' ability to rate themselves across all these different experiences. In this way, this instrument can make an important contribution to bridging the gap between two dominant approaches to measure SRL, the traditional aptitude and event measurement approach.

  1. Evaluation of precision in measurements of uranium isotope ratio by thermionic mass spectrometry

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de; Rodrigues, C.

    1977-01-01

    The parameters which affect the precision and accuracy of uranium isotopic ratios measurements by thermionic mass spectrometry are discussed. A statistical designed program for the analysis of the internal and external variances are presented. It was done an application of this statistical methods, in order to get mass discrimination factor, and its standard mean deviation, by using some results already published for 235 U/ 238 U ratio in NBS uranium samples, and natural uranium [pt

  2. Direct measurement of the initial proton extrusion to oxygen uptake ratio accompanying succinate oxidation by rat liver mitochondria.

    Science.gov (United States)

    Setty, O H; Shrager, R I; Bunow, B; Reynafarje, B; Lehninger, A L; Hendler, R W

    1986-01-01

    The problem of obtaining very early ratios for the H+/O stoichiometry accompanying succinate oxidation by rat liver mitochondria was attacked using new techniques for direct measurement rather than extrapolations based on data obtained after mixing and the recovery of the electrode from initial injection of O2. Respiration was quickly initiated in a thoroughly mixed O2-containing suspension of mitochondria under a CO atmosphere by photolysis of the CO-cytochrome c oxidase complex-. Fast responding O2 and pH electrodes were used to collect data every 10 ms. The response time for each electrode was experimentally measured in each experiment and suitable corrections for electrode relaxations were made. With uncorrected data obtained after 0.8 s, the extrapolation back to zero time on the basis of single-exponential curve fitting confirmed values close to 8.0 as previously reported (Costa et al., 1984). The data directly obtained, however, indicate an initial burst in H+/O ratio that peaked to values of approximately 20 to 30 prior to 50 ms and which was no longer evident after 0.3 s. Newer information and considerations that place all extrapolation methods in question are discussed. PMID:3019443

  3. Smile satisfaction and its related indicators in students of School of Dentistry, Qazvin University of Medical Sciences (2013-2014

    Directory of Open Access Journals (Sweden)

    B. Ranjbar Omidi

    2015-12-01

    Full Text Available Background: Smile is one of the most important factors determining the attractiveness of a person and has an important role in his mood and influence on others. Objective: The aim of this study was to evaluate the smile satisfaction and its related indicators in the students of School of Dentistry affiliated to Qazvin University of Medical Sciences. Methods: This cross sectional study was conducted on 80 students of School of Dentistry in Qazvin during 2013-2014. Digital photograph was provided from students’ smile. Smile esthetics of pictures was evaluated by three faculty members of restorative and orthodontics departments based on visual analogue scale. Smile satisfaction was evaluated by the students. Smile line ratio, buccal corridor ratio and symmetric ratio were measured by Photo shop CS5 software. Data were analyzed using Pearson’s correlation coefficient. Findings: Mean smile esthetics score was 59±10.5 and 71±9.4 in male and female students, respectively and the difference was statistically significant. Mean self-reported smile satisfaction was 73.7±7.8% and 72.4±17.9% in male and female students, respectively and the difference was not statistically significant. Smile line ratio was significantly different between male and female students, but the differences in buccal corridor ratio and symmetric ratio was not statistically significant. There was positive significant correlation between smile line ratio and smile esthetics score. Among the morphometric indices, only smile line ratio had significant correlation with smile satisfaction in male students. Conclusion: The correlation between smile line ratio and smile satisfaction indicates the high capability of this morphometric index for evaluating smile satisfaction.

  4. Measurement and Study of Lidar Ratio by Using a Raman Lidar in Central China

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2016-05-01

    Full Text Available We comprehensively evaluated particle lidar ratios (i.e., particle extinction to backscatter ratio at 532 nm over Wuhan in Central China by using a Raman lidar from July 2013 to May 2015. We utilized the Raman lidar data to obtain homogeneous aerosol lidar ratios near the surface through the Raman method during no-rain nights. The lidar ratios were approximately 57 ± 7 sr, 50 ± 5 sr, and 22 ± 4 sr under the three cases with obviously different pollution levels. The haze layer below 1.8 km has a large particle extinction coefficient (from 5.4e-4 m−1 to 1.6e-4 m−1 and particle backscatter coefficient (between 1.1e-05 m−1sr−1 and 1.7e-06 m−1sr−1 in the heavily polluted case. Furthermore, the particle lidar ratios varied according to season, especially between winter (57 ± 13 sr and summer (33 ± 10 sr. The seasonal variation in lidar ratios at Wuhan suggests that the East Asian monsoon significantly affects the primary aerosol types and aerosol optical properties in this region. The relationships between particle lidar ratios and wind indicate that large lidar ratio values correspond well with weak winds and strong northerly winds, whereas significantly low lidar ratio values are associated with prevailing southwesterly and southerly wind.

  5. Measurement and Study of Lidar Ratio by Using a Raman Lidar in Central China.

    Science.gov (United States)

    Wang, Wei; Gong, Wei; Mao, Feiyue; Pan, Zengxin; Liu, Boming

    2016-05-18

    We comprehensively evaluated particle lidar ratios (i.e., particle extinction to backscatter ratio) at 532 nm over Wuhan in Central China by using a Raman lidar from July 2013 to May 2015. We utilized the Raman lidar data to obtain homogeneous aerosol lidar ratios near the surface through the Raman method during no-rain nights. The lidar ratios were approximately 57 ± 7 sr, 50 ± 5 sr, and 22 ± 4 sr under the three cases with obviously different pollution levels. The haze layer below 1.8 km has a large particle extinction coefficient (from 5.4e-4 m(-1) to 1.6e-4 m(-1)) and particle backscatter coefficient (between 1.1e-05 m(-1)sr(-1) and 1.7e-06 m(-1)sr(-1)) in the heavily polluted case. Furthermore, the particle lidar ratios varied according to season, especially between winter (57 ± 13 sr) and summer (33 ± 10 sr). The seasonal variation in lidar ratios at Wuhan suggests that the East Asian monsoon significantly affects the primary aerosol types and aerosol optical properties in this region. The relationships between particle lidar ratios and wind indicate that large lidar ratio values correspond well with weak winds and strong northerly winds, whereas significantly low lidar ratio values are associated with prevailing southwesterly and southerly wind.

  6. Self-statements, self-esteem, and locus of control in discriminating college students' scores on the Beck Depression Inventory.

    Science.gov (United States)

    Madonna, S; Philpot, V D

    1996-04-01

    To study the use of the ratio of positive to negative self-statements, locus of control, and self-esteem in discriminating between scores on the Beck Depression Inventory 145 undergraduate college students were administered the Beck Depression Inventory, Automatic Thoughts Questionnaire-Revised, Coopersmith Self-esteem Inventory-Adult Form, and the Rotter Locus of Control scale in their classrooms. A stepwise discriminant analysis indicated that five variables combined to yield a statistically significant discrimination among low, middle, and high scores on the Beck Depression Inventory. The classification analysis indicated that 77.1% (n = 111) of the undergraduate students were correctly classified; 93.2% (82 of 88) were correctly classified as low scorers and 73.3% (18 of 46) were correctly classified as high scorers.

  7. The Implicit Relational Assessment Procedure as a Measure of Self-Esteem

    Science.gov (United States)

    Timko, C. Alix; England, Erica L.; Herbert, James D.; Forman, Evan M.

    2010-01-01

    Two studies were conducted to pilot the Implicit Relational Assessment Procedure (IRAP) in measuring attitudes toward the self: one related to body image specifically and another assessing the broader construct of self-esteem. Study 1 utilized the IRAP with female college students to examine self-referential beliefs regarding body image. Results…

  8. Cognitive indicators of social anxiety in youth: a structural equation analysis.

    Science.gov (United States)

    Rudy, Brittany M; Davis, Thompson E; Matthews, Russell A

    2014-01-01

    Previous studies have demonstrated significant relationships among various cognitive variables such as negative cognition, self-efficacy, and social anxiety. Unfortunately, few studies focus on the role of cognition among youth, and researchers often fail to use domain-specific measures when examining cognitive variables. Therefore, the purpose of the present study was to examine domain-specific cognitive variables (i.e., socially oriented negative self-referent cognition and social self-efficacy) and their relationships to social anxiety in children and adolescents using structural equation modeling techniques. A community sample of children and adolescents (n=245; 55.9% female; 83.3% Caucasian, 9.4% African American, 2% Asian, 2% Hispanic, 2% "other," and 1.2% not reported) completed questionnaires assessing social cognition and social anxiety symptomology. Three latent variables were created to examine the constructs of socially oriented negative self-referent cognition (as measured by the SONAS scale), social self-efficacy (as measured by the SEQSS-C), and social anxiety (as measured by the SPAI-C and the Brief SA). The resulting measurement model of latent variables fit the data well. Additionally, consistent with the study hypothesis, results indicated that social self-efficacy likely mediates the relationship between socially oriented negative self-referent cognition and social anxiety, and socially oriented negative self-referent cognition yields significant direct and indirect effects on social anxiety. These findings indicate that socially oriented negative cognitions are associated with youth's beliefs about social abilities and the experience of social anxiety. Future directions for research and study limitations, including use of cross-sectional data, are discussed. © 2013.

  9. THE CONSTRUCTION OF A QUESTIONNAIRE TO MEASURE SELF-INDUCED CONCATENATED DEMOTIVATION

    Directory of Open Access Journals (Sweden)

    Josko Sindik

    2013-12-01

    Full Text Available The concept of self-induced concatenated demotivation describes the “chain“ of demotivational processes and interactions of employees, in the contexts of postsocialism, job characteristics, dominant forms of motivation and group cohesion in work organizations. The aim of the preliminary research was to construct a questionnaire to measure the concept of self-induced concatenated demotivation and the relations between its latent dimensions. The study included a “snowball“ sample of 196 participants aged 20 to 65, of both genders, with heterogeneous professions and degrees in education. Based on the results of factor analysis three latent dimensions have been obtained, that account for only 36% of the total variance of the manifest area of self-induced concatenated demotivation, which we have named: pessimism/rationalization, social orientation, the ability to evaluate other people. The questionnaire to measure self-induced concatenated demotivation of employees has proved to be a low but satisfactory reliable measuring instrument for all three dimensions of the concept.

  10. Income and Physical Activity among Adults: Evidence from Self-Reported and Pedometer-Based Physical Activity Measurements.

    Science.gov (United States)

    Kari, Jaana T; Pehkonen, Jaakko; Hirvensalo, Mirja; Yang, Xiaolin; Hutri-Kähönen, Nina; Raitakari, Olli T; Tammelin, Tuija H

    2015-01-01

    This study examined the relationship between income and physical activity by using three measures to illustrate daily physical activity: the self-reported physical activity index for leisure-time physical activity, pedometer-based total steps for overall daily physical activity, and pedometer-based aerobic steps that reflect continuous steps for more than 10 min at a time. The study population consisted of 753 adults from Finland (mean age 41.7 years; 64% women) who participated in 2011 in the follow-up of the ongoing Young Finns study. Ordinary least squares models were used to evaluate the associations between income and physical activity. The consistency of the results was explored by using register-based income information from Statistics Finland, employing the instrumental variable approach, and dividing the pedometer-based physical activity according to weekdays and weekend days. The results indicated that higher income was associated with higher self-reported physical activity for both genders. The results were robust to the inclusion of the control variables and the use of register-based income information. However, the pedometer-based results were gender-specific and depended on the measurement day (weekday vs. weekend day). In more detail, the association was positive for women and negative or non-existing for men. According to the measurement day, among women, income was positively associated with aerobic steps despite the measurement day and with totals steps measured on the weekend. Among men, income was negatively associated with aerobic steps measured on weekdays. The results indicate that there is an association between income and physical activity, but the association is gender-specific and depends on the measurement type of physical activity.

  11. Novel biliary self-expanding metal stents: indications and applications.

    Science.gov (United States)

    Blero, Daniel; Huberty, Vincent; Devière, Jacques

    2015-03-01

    Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.

  12. Performance evaluation using bootstrapping DEA techniques: Evidence from industry ratio analysis

    OpenAIRE

    Halkos, George; Tzeremes, Nickolaos

    2010-01-01

    In Data Envelopment Analysis (DEA) context financial data/ ratios have been used in order to produce a unified measure of performance metric. However, several scholars have indicated that the inclusion of financial ratios create biased efficiency estimates with implications on firms’ and industries’ performance evaluation. There have been several DEA formulations and techniques dealing with this problem including sensitivity analysis, Prior-Ratio-Analysis and DEA/ output–input ratio analysis ...

  13. High-precision branching ratio measurement for the superallowed β+ emitter Ga62

    Science.gov (United States)

    Finlay, P.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Towner, I. S.; Austin, R. A. E.; Bandyopadhyay, D.; Chaffey, A.; Chakrawarthy, R. S.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hyland, B.; Kanungo, R.; Leach, K. G.; Mattoon, C. M.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Ressler, J. J.; Sarazin, F.; Savajols, H.; Schumaker, M. A.; Wong, J.

    2008-08-01

    A high-precision branching ratio measurement for the superallowed β+ decay of Ga62 was performed at the Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. The 8π spectrometer, an array of 20 high-purity germanium detectors, was employed to detect the γ rays emitted following Gamow-Teller and nonanalog Fermi β+ decays of Ga62, and the SCEPTAR plastic scintillator array was used to detect the emitted β particles. Thirty γ rays were identified following Ga62 decay, establishing the superallowed branching ratio to be 99.858(8)%. Combined with the world-average half-life and a recent high-precision Q-value measurement for Ga62, this branching ratio yields an ft value of 3074.3±1.1 s, making Ga62 among the most precisely determined superallowed ft values. Comparison between the superallowed ft value determined in this work and the world-average corrected F tmacr value allows the large nuclear-structure-dependent correction for Ga62 decay to be experimentally determined from the CVC hypothesis to better than 7% of its own value, the most precise experimental determination for any superallowed emitter. These results provide a benchmark for the refinement of the theoretical description of isospin-symmetry breaking in A⩾62 superallowed decays.

  14. Self-Reported Health among Older Bangladeshis: How Good a Health Indicator Is It?

    Science.gov (United States)

    Rahman, M. Omar; Barsky, Arthur J.

    2003-01-01

    Purpose: This study examines the value of self-reported health (SRH) as an indicator of underlying health status in a developing country setting. Design and Methods: Logistic regression methods with adjustments for multistage sampling are used to examine the factors associated with SRH in 2,921 men and women aged 50 and older in rural Bangladesh.…

  15. Measuring cross-border regional integration with composite indicators

    DEFF Research Database (Denmark)

    Makkonen, Teemu

    2016-01-01

    Earlier quantitative studies on cross-border regional integration processes have commonly neglected science, technology and innovation (STI) indicators: even the most notable example of a composite indicator approach to measuring cross-border regional integration, i.e. the Oresund index, lacks...... a sub-category for STI. Consequently, by ignoring cross-border innovation and knowledge flows, the Oresund integration index fails to take into account one of the most important drivers of economic growth in cross-border regions. Therefore, a new composite STI indicator (sub-category) was introduced......-border regions....

  16. The COPD Helplessness Index: a new tool to measure factors affecting patient self-management.

    Science.gov (United States)

    Omachi, Theodore A; Katz, Patricia P; Yelin, Edward H; Iribarren, Carlos; Knight, Sara J; Blanc, Paul D; Eisner, Mark D

    2010-04-01

    Psychologic factors affect how patients with COPD respond to attempts to improve their self-management skills. Learned helplessness may be one such factor, but there is no validated measure of helplessness in COPD. We administered a new COPD Helplessness Index (CHI) to 1,202 patients with COPD. Concurrent validity was assessed through association of the CHI with established psychosocial measures and COPD severity. The association of helplessness with incident COPD exacerbations was then examined by following subjects over a median 2.1 years, defining COPD exacerbations as COPD-related hospitalizations or ED visits. The CHI demonstrated internal consistency (Cronbach alpha = 0.75); factor analysis was consistent with the CHI representing a single construct. Greater CHI-measured helplessness correlated with greater COPD severity assessed by the BODE (Body-mass, Obstruction, Dyspnea, Exercise) Index (r = 0.34; P Controlling for sociodemographics and smoking status, helplessness was prospectively associated with incident COPD exacerbations (hazard ratio = 1.31; P controlling for the BODE Index, helplessness remained predictive of COPD exacerbations among subjects with BODE Index useful tool in analyzing differential clinical responses mediated by patient-centered attributes.

  17. High-precision half-life and branching-ratio measurements for superallowed Fermi β+ emitters at TRIUMF - ISAC

    Science.gov (United States)

    Laffoley, A. T.; Dunlop, R.; Finlay, P.; Grinyer, G. F.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Blank, B.; Bouzomita, H.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Demand, G.; Diaz Varela, A.; Djongolov, M.; Ettenauer, S.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Glister, J.; Green, K. L.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Pearson, C. J.; Phillips, A. A.; Rand, E. T.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Tardiff, E. R.; Thomas, J. C.; Towner, I. S.; Triambak, S.; Unsworth, C.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.

    2014-03-01

    A program of high-precision half-life and branching-ratio measurements for superallowed Fermi β emitters is being carried out at TRIUMF's Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. Recent half-life measurements for the superallowed decays of 14O, 18Ne, and 26Alm, as well as branching-ratio measurements for 26Alm and 74Rb are reported. These results provide demanding tests of the Standard Model and the theoretical isospin symmetry breaking (ISB) corrections in superallowed Fermi β decays.

  18. Self-concept, self-esteem, gender, race, and information technology use.

    Science.gov (United States)

    Jackson, Linda A; Zhao, Yong; Witt, Edward A; Fitzgerald, Hiram E; von Eye, Alexander; Harold, Rena

    2009-08-01

    This research addressed two fundamental questions regarding self-concept, self-esteem, gender, race, and information technology use. First, is technology use related to dimensions of self-concept and/or to self-esteem? Second, are there gender and/or race differences in self-concept, self-esteem, and technology use? Five hundred youth, average age 12 years old, one third African American and two thirds Caucasian American, completed multidimensional measures of self-concept, the Rosenberg Self-Esteem scale, and measures of frequency of Internet use, Internet use for communication (e-mail and instant messaging), video game playing, and cell phone use. Findings indicated that technology use predicted dimensions of self-concept and self-esteem, with video game playing having a negative influence and Internet use having a positive influence on self-concept dimensions. Gender differences were observed on several self-concept dimensions, but contrary to expectations, girls did not score higher than boys in social self-concept. Only one race difference was observed: African Americans had lower behavioral self-concept than did Caucasian Americans. Implications of the benefits and liabilities of youth's current and projected technology use are discussed.

  19. Psychological Correlates of Self-Reported and Objectively Measured Physical Activity among Chinese Children—Psychological Correlates of PA

    Directory of Open Access Journals (Sweden)

    Jing-Jing Wang

    2016-10-01

    Full Text Available This study aimed to explore the associations among psychological correlates and physical activity (PA in Chinese children and to further examine whether these associations varied by different PA measures. PA self-efficacy, motivation, and preference were reported in 449 8–13-year-old Chinese children (252 males. Moderate- to vigorous- intensity PA (MVPA was measured by the Physical Activity Questionnaire for Older Children (PAQ-C and with an ActiGraph GT3X accelerometer. Correlations and hierarchical regressions were performed to explore their associations. The study psychological variables were all positively related to PAQ-C and objective MVPA (r: 0.22–0.63. The associations with PAQ-C were all substantially stronger than those with accelerometry. Beyond the explained variance accounted for by demographics and social desirability, the addition of the psychological correlates accounted for 45% of the variance of the PAQ-C score, while only 13% for accelerometry-based MVPA. The associations of specific variables with the PAQ-C score (age, PA self-efficacy, autonomous motivation and preference were somewhat different from those associated with objective MVPA (PA self-efficacy, autonomous motivation, and negatively associated with female gender. This study demonstrated the importance of self-efficacy and autonomous motivation in association with PA and indicated the difference in level of their associations with different PA measures.

  20. Psychological Correlates of Self-Reported and Objectively Measured Physical Activity among Chinese Children—Psychological Correlates of PA

    Science.gov (United States)

    Wang, Jing-Jing; Baranowski, Tom; Lau, Patrick W. C.; Chen, Tzu-An; Zhang, Shu-Ge

    2016-01-01

    This study aimed to explore the associations among psychological correlates and physical activity (PA) in Chinese children and to further examine whether these associations varied by different PA measures. PA self-efficacy, motivation, and preference were reported in 449 8–13-year-old Chinese children (252 males). Moderate- to vigorous- intensity PA (MVPA) was measured by the Physical Activity Questionnaire for Older Children (PAQ-C) and with an ActiGraph GT3X accelerometer. Correlations and hierarchical regressions were performed to explore their associations. The study psychological variables were all positively related to PAQ-C and objective MVPA (r: 0.22–0.63). The associations with PAQ-C were all substantially stronger than those with accelerometry. Beyond the explained variance accounted for by demographics and social desirability, the addition of the psychological correlates accounted for 45% of the variance of the PAQ-C score, while only 13% for accelerometry-based MVPA. The associations of specific variables with the PAQ-C score (age, PA self-efficacy, autonomous motivation and preference) were somewhat different from those associated with objective MVPA (PA self-efficacy, autonomous motivation, and negatively associated with female gender). This study demonstrated the importance of self-efficacy and autonomous motivation in association with PA and indicated the difference in level of their associations with different PA measures. PMID:27754396

  1. Psychological Correlates of Self-Reported and Objectively Measured Physical Activity among Chinese Children-Psychological Correlates of PA.

    Science.gov (United States)

    Wang, Jing-Jing; Baranowski, Tom; Lau, Patrick W C; Chen, Tzu-An; Zhang, Shu-Ge

    2016-10-13

    This study aimed to explore the associations among psychological correlates and physical activity (PA) in Chinese children and to further examine whether these associations varied by different PA measures. PA self-efficacy, motivation, and preference were reported in 449 8-13-year-old Chinese children (252 males). Moderate- to vigorous- intensity PA (MVPA) was measured by the Physical Activity Questionnaire for Older Children (PAQ-C) and with an ActiGraph GT3X accelerometer. Correlations and hierarchical regressions were performed to explore their associations. The study psychological variables were all positively related to PAQ-C and objective MVPA ( r : 0.22-0.63). The associations with PAQ-C were all substantially stronger than those with accelerometry. Beyond the explained variance accounted for by demographics and social desirability, the addition of the psychological correlates accounted for 45% of the variance of the PAQ-C score, while only 13% for accelerometry-based MVPA. The associations of specific variables with the PAQ-C score (age, PA self-efficacy, autonomous motivation and preference) were somewhat different from those associated with objective MVPA (PA self-efficacy, autonomous motivation, and negatively associated with female gender). This study demonstrated the importance of self-efficacy and autonomous motivation in association with PA and indicated the difference in level of their associations with different PA measures.

  2. The Myth of Offenders' Deception on Self-Report Measure Predicting Recidivism: Example from the Self-Appraisal Questionnaire (SAQ)

    Science.gov (United States)

    Loza, Wagdy; Loza-Fanous, Amel; Heseltine, Karen

    2007-01-01

    Two studies were conducted to investigate the vulnerability of the Self-Appraisal Questionnaire (SAQ) to deception and self-presentation biases. The SAQ is a self-report measure used to predict recidivism and guide institutional and program assignments. In the first study, comparisons were made between 429 volunteer offenders who completed the SAQ…

  3. Measurement of β/Λ ratio in IEA-R1 reactor using noise technique

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Kassar, E.

    1986-01-01

    The ratio β/Λ for the IEA-R1 reactor is obtained experimentally through the noise analysis technique. This technique is based on the determination of the power spectral density of the reactor neutron population, with the reactor in a subcritical state driven by a 'white' neutron source. A ratio β/Λ of 43,5 s -1 is estimated from the break frequency of the measured transfer function of the IEA-R1 reactor. (Author) [pt

  4. A novel self-embrittling strippable coating for radioactive decontamination based on silicone modified styrene-acrylic emulsion

    Science.gov (United States)

    Wang, Jing; Wang, Jianhui; Zheng, Li; Li, Jian; Cui, Can; Lv, Linmei

    2017-03-01

    Silicone modified styrene-acrylic emulsion and butyl acrylate were used as a main film-forming agent and an additive respectively to synthesize a self-embrittling strippable coating. The doping mass-ratio of butyl acrylate was adjusted at 0, 5%, 10%, 15%, 20%, and the results indicated the optimized doping ratio was 10%. Ca(OH)2 was used to promote the coating film self-embrittling at a moderate doping mass-ratio of 20%. The synthesized coating’s coefficients of α and β decontamination on concrete, marble, glass and stainless steel surfaces were both greater than 85%, which indicated the synthesized coating is a promising cleaner for radioactive decontamination.

  5. The Self Attenuation Correction for Holdup Measurements, a Historical Perspective

    International Nuclear Information System (INIS)

    Oberer, R. B.; Gunn, C. A.; Chiang, L. G.

    2006-01-01

    Self attenuation has historically caused both conceptual as well as measurement problems. The purpose of this paper is to eliminate some of the historical confusion by reviewing the mathematical basis and by comparing several methods of correcting for self attenuation focusing on transmission as a central concept

  6. Measuring Students' Self-Perceived Competence in Home Economics Core Areas.

    Science.gov (United States)

    Smith, Frances M.

    1990-01-01

    Using the self-efficacy concept from Bandura's social learning theory, researchers developed an instrument to measure students' self-perceived competence in home economics core areas. Administration to all graduate students at a midwestern university during 1982-88 verified eight original competence areas and added a ninth. (SK)

  7. Isotope ratios as pollutant source and behaviour indicators

    International Nuclear Information System (INIS)

    1975-01-01

    Recent years have witnessed significant advances in isotope techniques for identifying origins and for studying the behaviour of trace contaminants and pollutants of the environment under actual existing environmental conditions. Improvements in the supply of stable isotopes and their labelled compounds, instrumental analysis and information on stable or radioactive isotopic ratios of existing environmental contaminants as a function of origin or behaviour have provided relatively new tools for the environmental scientist. While variations in natural or existing environmental stable and radioactive nuclides could be regarded as 'background noise' in conventional tracer experiments they promised unique information about sources and behaviour to those who listened carefully. (author)

  8. The Moral Self-Image Scale: Measuring and Understanding the Malleability of the Moral Self

    Directory of Open Access Journals (Sweden)

    Jennifer eJordan

    2015-12-01

    Full Text Available Recent ethical decision-making models suggest that individuals’ own view of their morality is malleable rather than static, responding to their (immoral actions and reflections about the world around them. Yet no construct currently exists to represent the malleable state of a person’s moral self-image (MSI. In this investigation, we define this construct, as well as develop a scale to measure it. Across five studies, we show that feedback about the moral self alters an individual’s MSI as measured by our scale. We also find that MSI is related to, but distinct from, related constructs, including moral identity, self-esteem, and moral disengagement. In Study 1, we administered the MSI scale and several other relevant scales to demonstrate convergent and discriminant validity. In Study 2, we examine the relationship between the MSI and one’s ought versus ideal self. In Studies 3 and 4, we find that one’s MSI is affected in the predicted directions by manipulated feedback about the moral self, including feedback related to social comparisons of moral behavior (Study 3 and feedback relative to one’s own moral ideal (Study 4. Lastly, Study 5 provides evidence that the recall of one’s moral or immoral behavior alters people’s MSI in the predicted directions. Taken together, these studies suggest that the MSI is malleable and responds to individuals’ moral and immoral actions in the outside world. As such, the MSI is an important variable to consider in the study of moral and immoral behavior.

  9. Body conscious? Interoceptive awareness, measured by heartbeat perception, is negatively correlated with self-objectification.

    Science.gov (United States)

    Ainley, Vivien; Tsakiris, Manos

    2013-01-01

    'Self-objectification' is the tendency to experience one's body principally as an object, to be evaluated for its appearance rather than for its effectiveness. Within objectification theory, it has been proposed that self-objectification accounts for the poorer interoceptive awareness observed in women, as measured by heartbeat perception. Our study is, we believe, the first specifically to test this relationship. Using a well-validated and reliable heartbeat perception task, we measured interoceptive awareness in women and compared this with their scores on the Self-Objectification Questionnaire, the Self-Consciousness Scale and the Body Consciousness Questionnaire. Interoceptive awareness was negatively correlated with self-objectification. Interoceptive awareness, public body consciousness and private body consciousness together explained 31% of the variance in self-objectification. However, private body consciousness was not significantly correlated with interoceptive awareness, which may explain the many nonsignificant results in self-objectification studies that have used private body consciousness as a measure of body awareness. We propose interoceptive awareness, assessed by heartbeat perception, as a measure of body awareness in self-objectification studies. Our findings have implications for those clinical conditions, in women, which are characterised by self-objectification and low interoceptive awareness, such as eating disorders.

  10. Measurements of the Proton Elastic-Form-Factor Ratio μpGEp/GMp at Low Momentum Transfer

    International Nuclear Information System (INIS)

    Ron, G.; Piasetzky, E.; Pomerantz, I.; Shneor, R.; Glister, J.; Lee, B.; Choi, Seonho; Kang, H.; Oh, Y.; Song, J.; Yan, X.; Allada, K.; Dutta, C.; Armstrong, W.; Meziani, Z.-E.; Yao, H.; Arrington, J.; Solvignon, P.; Beck, A.; May-Tal Beck, S.

    2007-01-01

    High-precision measurements of the proton elastic form-factor ratio, μ p G E p /G M p , have been made at four-momentum transfer, Q 2 , values between 0.2 and 0.5 GeV 2 . The new data, while consistent with previous results, clearly show a ratio less than unity and significant differences from the central values of several recent phenomenological fits. By combining the new form-factor ratio data with an existing cross-section measurement, one finds that in this Q 2 range the deviation from unity is primarily due to G E p being smaller than expected

  11. Measurement of signal-to-noise ratio performance of TV fluoroscopy systems

    International Nuclear Information System (INIS)

    Geluk, R.J.

    1985-01-01

    A method has been developed for direct measurement of Signal-to-Noise ratio performance on X-ray TV systems. To this end the TV signal resulting from a calibrated test object, is compared with the noise level in the image. The method is objective and produces instantaneous readout, which makes it very suitable for system evaluation under dynamic conditions. (author)

  12. Stress ratio determination from the core-disking phenomenon

    International Nuclear Information System (INIS)

    Lehnhoff, T.F.; Stefansson, B.; Thirumalai, K.

    1982-08-01

    The ability to predict in situ stress conditions from standard core samples offers planning and site-selection advantages for most underground facilities. This paper presents an empirical relation for estimating the horizontal to vertical stress ratio in basalt. The resulting estimates can then be used to help assess the extent to which measurement of in situ stress is required. The core disking phenomenon has long been used as an indicator of high in situ stress. It is concluded that disks form as the result of tensile failure initiation rather than shear failure initiation of the core. It is deduced that the tensile failure begins at the edge of the core and propagates toward the center in shear rather than beginning at the center and propagating outward. An empirical relation for horizontal to vertical stress ratio variation with depth has been developed and is shown to agree substantially with previous measured horizontal to vertical stress ratios for locations in several areas of the world. The stress-ratio predictions are justified based on finite-element studies using linear elastic analysis and also nonlinear (tension cut-off) analysis. Indications of fracture propagation paths were determined from the analyses. The shape of the predicted propagation path agrees well with physical observations

  13. Online stable carbon isotope ratio measurement in formic acid, acetic acid, methanol and ethanol in water by high performance liquid chromatography-isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Tagami, Keiko; Uchida, Shigeo

    2008-01-01

    A suitable analysis condition was determined for high performance liquid chromatography-isotope ratio mass spectrometry (HPLC-IRMS) while making sequential measurements of stable carbon isotope ratios of δ 13 C in formic acid, acetic acid, methanol and ethanol dissolved in water. For this online column separation method, organic reagents are not applicable due to carbon contamination; thus, water and KH 2 PO 4 at low concentrations were tested as mobile phase in combination with a HyPURITY AQUASTAR TM column. Formic acid, acetic acid, methanol and ethanol were separated when 2 mM KH 2 PO 4 aqueous solution was used. Under the determined analysis condition for HPLC-IRMS, carbon concentrations could be measured quantitatively as well as carbon isotope ratio when carbon concentration was higher than 0.4 mM L for each chemical

  14. Basic study of water-cement ratio evaluation for fresh mortar using an ultrasonic measurement technique

    International Nuclear Information System (INIS)

    Hamza Haffies Ismail; Murata, Yorinobu

    2009-01-01

    The objective of this research is for the basic study of ultrasonic evaluation method for the determination of the water-cement-ratio (W/C) in fresh concrete at the early age of hardening. Water-cement ratio is a important parameter to evaluate the strength of concrete for concrete construction. Using an ultrasonic pulse measurement technique, wave velocity and frequency variations depend on the age of concrete during hardening process could be evaluated. As a sample test, fresh mortar of water-cement ratio of 40 %, 50% and 60 % was poured into cylindrical plastic mould form (φ100 mm x 50 mm). For an ultrasonic pulse wave transmission technique, two wide band ultrasonic transducers were set on the top and bottom surface of mortar, and start measuring from 10 minutes after pouring water until 60 minutes of 5 minutes of intervals. As a result, it was confirmed that wave velocity and center frequency were changed with the age of mortar depends on the water-cement ratio. (author)

  15. Amphibious hearing in spotted seals (Phoca largha): underwater audiograms, aerial audiograms and critical ratio measurements.

    Science.gov (United States)

    Sills, Jillian M; Southall, Brandon L; Reichmuth, Colleen

    2014-03-01

    Spotted seals (Phoca largha) inhabit Arctic regions that are facing both rapid climate change and increasing industrialization. While little is known about their sensory capabilities, available knowledge suggests that spotted seals and other ice seals use sound to obtain information from the surrounding environment. To quantitatively assess their auditory capabilities, the hearing of two young spotted seals was tested using a psychophysical paradigm. Absolute detection thresholds for tonal sounds were measured in air and under water over the frequency range of hearing, and critical ratios were determined using octave-band masking noise in both media. The behavioral audiograms show a range of best sensitivity spanning four octaves in air, from approximately 0.6 to 11 kHz. The range of sensitive hearing extends across seven octaves in water, with lowest thresholds between 0.3 and 56 kHz. Critical ratio measurements were similar in air and water and increased monotonically from 12 dB at 0.1 kHz to 30 dB at 25.6 kHz, indicating that the auditory systems of these seals are quite efficient at extracting signals from background noise. This study demonstrates that spotted seals possess sound reception capabilities different from those previously described for ice seals, and more similar to those reported for harbor seals (Phoca vitulina). The results are consistent with the amphibious lifestyle of these seals and their apparent reliance on sound. The hearing data reported herein are the first available for spotted seals and can inform best management practices for this vulnerable species in a changing Arctic.

  16. Uncertainties achievable for uranium isotope-amount ratios. Estimates based on the precision and accuracy of recent characterization measurements

    International Nuclear Information System (INIS)

    Mathew, K.J.; Essex, R.M.; Gradle, C.; Narayanan, U.

    2015-01-01

    Certified reference materials (CRMs) recently characterized by the NBL for isotope-amount ratios are: (i) CRM 112-A, Uranium (normal) Metal Assay and Isotopic Standard, (ii) CRM 115, Uranium (depleted) Metal Assay and Isotopic Standard, and (iii) CRM 116-A, Uranium (enriched) Metal Assay and Isotopic Standard. NBL also completed re-characterization of the isotope-amount ratios in CRM 125-A, Uranium (UO 2 ) Pellet Assay, Isotopic, and Radio-chronometric Standard. Three different TIMS analytical techniques were employed for the characterization analyses. The total evaporation technique was used for the major isotope-amount ratio measurement, the modified total evaporation technique was used for both the major and minor isotope-amount ratios, and minor isotope-amount ratios were also measured using a Conventional technique. Uncertainties for the characterization studies were calculated from the combined TIMS data sets following the ISO Guide to the expression of uncertainty in measurement. The uncertainty components for the isotope-amount ratio values are discussed. (author)

  17. Structural Integrity in Measures of Self Concept.

    Science.gov (United States)

    Stenner, A. Jackson; Katzenmeyer, W.G.

    Structural integrity of a measure is defined in terms of its replicability, constancy, invariance, and stability. Work completed in the development and validation of the Self Observation Scales (SOS) Primary Level (Stenner and Katzenmeyer, 1973) serves to illustrate one method of establishing structural integrity. The name of each scale of the SOS…

  18. Measuring coverage in MNCH: indicators for global tracking of newborn care.

    Directory of Open Access Journals (Sweden)

    Allisyn C Moran

    Full Text Available Neonatal mortality accounts for 43% of under-five mortality. Consequently, improving newborn survival is a global priority. However, although there is increasing consensus on the packages and specific interventions that need to be scaled up to reduce neonatal mortality, there is a lack of clarity on the indicators needed to measure progress. In 2008, in an effort to improve newborn survival, the Newborn Indicators Technical Working Group (TWG was convened by the Saving Newborn Lives program at Save the Children to provide a forum to develop the indicators and standard measurement tools that are needed to measure coverage of key newborn interventions. The TWG, which included evaluation and measurement experts, researchers, individuals from United Nations agencies and non-governmental organizations, and donors, prioritized improved consistency of measurement of postnatal care for women and newborns and of immediate care behaviors and practices for newborns. In addition, the TWG promoted increased data availability through inclusion of additional questions in nationally representative surveys, such as the United States Agency for International Development-supported Demographic and Health Surveys and the United Nations Children's Fund-supported Multiple Indicator Cluster Surveys. Several studies have been undertaken that have informed revisions of indicators and survey tools, and global postnatal care coverage indicators have been finalized. Consensus has been achieved on three additional indicators for care of the newborn after birth (drying, delayed bathing, and cutting the cord with a clean instrument, and on testing two further indicators (immediate skin-to-skin care and applications to the umbilical cord. Finally, important measurement gaps have been identified regarding coverage data for evidence-based interventions, such as Kangaroo Mother Care and care seeking for newborn infection.

  19. Use of the strength ratio for pre-cracked Charpy specimens for the measuring, of the dynamic toughness of steels

    International Nuclear Information System (INIS)

    Pereira, L.C.; Darwish, F.A.I.

    1981-01-01

    The specimen strength ratio (R sub(sb)) determined for precraked Charpy specimens fractured in dynamic bending was correlated with plane strain fracture toughness (K sub(Id)) obtained through valid measurements of the J-integral at the moment of fracture initiation in various microstructures of the AISI 4140 steel. The results indicate a linear relationship between K sub(Id) and R sub(sb) for the microstructures considered in this work. The range of validity of this linear correlation is presented and discussed in terms of the ASTM E399 specimen size criterion. (Author) [pt

  20. Self-protection of FLIP fuel: Experimental measurements

    International Nuclear Information System (INIS)

    Johnson, A.G.; Ringle, J.C.; Anderson, T.V.; Dodd, B.; Bennett, S.; Carpenter, W.T.

    1980-01-01

    During the last year and one-half non-power reactor licensees of the Nuclear Regulatory Commission (NRC) have been repeatedly alerted to the fact that the Commission planned to tighten physical security regulations for their class of reactors. Essentially all of the new NRC physical security requirements for these reactors have been based on the type, quantity and enrichment of the special nuclear materials (e.g. enriched uranium and plutonium) possessed by the licensees. While each licensee's security classification will be evaluated individually, it is now apparent that non-power reactor licensees using or storing formula quantities of special nuclear material not meeting the 100 rem per hour at three feet self-protection exemption (e.g. 5 kilograms or more of non-self-protected fuel enriched to 20% or more with U-235) will be required to meet extremely stringent NRC physical security requirements patterned after the new Physical Protection Upgrade Rule. Implementation of these much stricter security requirements poses many economic and operational difficulties for university research reactors, to the point where facility closure could be the only alternative. TRIGA reactors utilizing a full FLIP fueled core, such as the Oregon State University TRIGA (OSTR), qualify for the highest physical protection category unless fuel can be maintained at self-protecting radiation levels. In order to demonstrate that OSTR fuel could be consistently kept above the 100 rem per hour threshold, a computer program was written which predicts the gamma radiation levels from an irradiated FLIP fuel element at 1, 2 and 3 feet in air and water. Furthermore, in order to verify the accuracy of the computer program, actual measurements of irradiated fuel elements were made at 3 feet in air and at 1, 2 and 3 feet in water, and the results compared very favorably to the predictions. The results of specific measurements, the instrumentation used and its calibration, the personnel doses

  1. Expected total counts for the Self-Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo [Belgian nuclear research centre SCK.CEN (Belgium); Universite Libre de Bruxelles (Belgium); Borella, Alessandro; Van der Meer, Klaas [Belgian nuclear research centre SCK.CEN. Boeretang 200, 2400 Mol (Belgium); Labeau, Pierre-Etienne; Pauly, Nicolas [Universite Libre de Bruxelles. Av. F. D. Roosevelt 50, B1050 Brussels (Belgium)

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in spent fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron counts in the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach in this study consisted in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types were used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the total neutron counts that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of total neutron counts and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the total neutron counts by increasing the detector size. The study shows that the highest total neutron counts are achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the total neutron counts

  2. Expected count rate for the Self- Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo [SCK.CEN, Belgian Nuclear Research Centre, Boeretang, 200 - B2400 Mol (Belgium); Universite libre de Bruxelles, Ecole polytechnique de Bruxelles - Service de Metrologie Nucleaire, CP 165/84, Avenue F.D. Roosevelt, 50 - B1050 Brussels (Belgium); Borella, Alessandro; Van der Meer, Klaas [SCK.CEN, Belgian Nuclear Research Centre, Boeretang, 200 - B2400 Mol (Belgium); Labeau, Pierre-Etienne; Pauly, Nicolas [Universite libre de Bruxelles, Ecole polytechnique de Bruxelles - Service de Metrologie Nucleaire, CP 165/84, Avenue F.D. Roosevelt, 50 - B1050 Brussels (Belgium)

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in the fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron flux integrated over the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach considered in this study consists in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types are used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the count rate that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of count rate and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the count rate by increasing the detector size. The study shows that the highest count rate is achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the count rate associated to each detector type

  3. Self-report and long-term field measures of MP3 player use: how accurate is self-report?

    Science.gov (United States)

    Portnuff, C D F; Fligor, B J; Arehart, K H

    2013-02-01

    This study was designed to evaluate the usage patterns of portable listening device (PLD) listeners, and the relationships between self-report measures and long-term dosimetry measures of listening habits. This study used a descriptive correlational design. Participants (N = 52) were 18-29 year old men and women who completed surveys. A randomly assigned subset (N = 24) of participants had their listening monitored by dosimetry for one week. Median weekly noise doses reported and measured through dosimetry were low (9-93%), but 14.3% of participants reported exceeding a 100% noise dose weekly. When measured by dosimetry, 16.7% of participants exceeded a 100% noise dose weekly. The self-report question that best predicted the dosimetry-measured dose asked participants to report listening duration and usual listening level on a visual-analog scale. This study reports a novel dosimetry system that can provide accurate measures of PLD use over time. When not feasible, though, the self-report question described could provide a useful research or clinical tool to estimate exposure from PLD use. Among the participants in this study, a small but substantial percentage of PLD users incurred exposure from PLD use alone that increases their risk of music-induced hearing loss.

  4. On-line component ratio measurement of oil/gas/water mixtures using an admittance sensor

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, J A

    1984-01-01

    The operator of a production platform is primarily interested in which types of fluids a well is producing and how quickly these different components are being produced. The component ratio and production rate of a well vary during the life of a field. To optimize production, measurement of each well's output is thus desirable. Current designs for subsea production systems lack means of continuously measuring three-component flows. A new method of component ratio measurement is described. The fraction of oil, gas and water flowing between two insulated electrode plates is determined by measuring both the electrical conductance and suseptance across the sensor. A preliminary evaluation of the new measurement system has been performed using a process oil/ water/air mixture. The method is not limited to small pipe diameters. The only possible limitation is that for low velocities in very large pipe diameters an in-line mixer may be required. Advantages of this new system are that real-time measurement of void fraction and water content is possible if a non-intrusive rugged sensor is used, and there are no range limitations, as each component may be measured for any given concentration. 4 references.

  5. Measure of significance of holotropic breathwork in the development of self-awareness

    DEFF Research Database (Denmark)

    Miller, Tanja; Nielsen, Laila

    2015-01-01

    OBJECTIVES: To investigate whether Holotropic Breathwork™ (HB; Grof Transpersonal Training, Mill Valley, CA) has any significance in the development of self-awareness. DESIGN: A quasi-experiment design and multiple case studies. A single case design was replicated. The statistical design was a re......OBJECTIVES: To investigate whether Holotropic Breathwork™ (HB; Grof Transpersonal Training, Mill Valley, CA) has any significance in the development of self-awareness. DESIGN: A quasi-experiment design and multiple case studies. A single case design was replicated. The statistical design...... MEASURES: The novices (n = 9) underwent positive temperament changes and the experienced participants (n = 11) underwent positive changes in character. Overall, positive self-awareness changes were indicated; the participants' (n = 20) scores for persistence temperament, interpersonal problems, overly.......864; pre-during-test p = 0.0215, pre-post-test p = 0.021, pre-post-test d = 0.5). Pre-test hostility mean (50.50 ± 10.395) decreased at post-test (47.20 ± 9.001; p = 0.0185; d = 0.3). The Inventory of Interpersonal Problems total pre-test mean (59.05 ± 17.139) was decreased at post-test (54.8 ± 12.408; p...

  6. Predicting intrapartum fetal compromise using the fetal cerebro-umbilical ratio.

    Science.gov (United States)

    Sabdia, S; Greer, R M; Prior, T; Kumar, S

    2015-05-01

    The aim of this study was to explore the association between the cerebro-umbilical ratio measured at 35-37 weeks and intrapartum fetal compromise. This retrospective cross sectional study was conducted at the Mater Mothers' Hospital in Brisbane, Australia. Maternal demographics and fetal Doppler indices at 35-37 weeks gestation for 1381 women were correlated with intrapartum and neonatal outcomes. Babies born by caesarean section or instrumental delivery for fetal compromise had the lowest median cerebro-umbilical ratio 1.60 (IQR 1.22-2.08) compared to all other delivery groups (vaginal delivery, emergency delivery for failure to progress, emergency caesarean section for other reasons or elective caesarean section). The percentage of infants with a cerebro-umbilical ratio cerebro-umbilical ratio between the 10th-90th centile and 9.6% of infants with a cerebro-umbilical ratio > 90th centile required delivery for the same indication (p cerebro-umbilical ratio was associated with an increased risk of emergency delivery for fetal compromise, OR 2.03 (95% CI 1.41-2.92), p cerebro-umbilical ratio measured at 35-37 weeks is associated with a greater risk of intrapartum compromise. This is a relatively simple technique which could be used to risk stratify women in diverse healthcare settings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. On the cross-sensitivity between water vapor mixing ratio and stable isotope measurements of in-situ analyzers

    KAUST Repository

    Parkes, Stephen

    2015-04-01

    In recent years there has been an increasing amount of water vapor stable isotope data collected using in-situ instrumentation. A number of papers have characterized the performance of these in-situ analyzers and suggested methods for calibrating raw measurements. The cross-sensitivity of the isotopic measurements on the mixing ratio has been shown to be a major uncertainty and a variety of techniques have been suggested to characterize this inaccuracy. However, most of these are based on relating isotopic ratios to water vapor mixing ratios from in-situ analyzers when the mixing ratio is varied and the isotopic composition kept constant. An additional correction for the span of the isotopic ratio scale is then applied by measuring different isotopic standards. Here we argue that the water vapor cross-sensitivity arises from different instrument responses (span and offset) of the parent H2O isotope and the heavier isotopes, rather than spectral overlap that could cause a true variation in the isotopic ratio with mixing ratio. This is especially relevant for commercial laser optical instruments where absorption lines are well resolved. Thus, the cross-sensitivity determined using more conventional techniques is dependent on the isotopic ratio of the standard used for the characterization, although errors are expected to be small. Consequently, the cross-sensitivity should be determined by characterizing the span and zero offset of each isotope mixing ratio. In fact, this technique makes the span correction for the isotopic ratio redundant. In this work we model the impact of changes in the span and offset of the heavy and light isotopes and illustrate the impact on the cross-sensitivity of the isotopic ratios on water vapor. This clearly shows the importance of determining the zero offset for the two isotopes. The cross-sensitivity of the isotopic ratios on water vapor is then characterized by determining the instrument response for the individual isotopes for a

  8. On the cross-sensitivity between water vapor mixing ratio and stable isotope measurements of in-situ analyzers

    KAUST Repository

    Parkes, Stephen; Wang,  Lixin; McCabe, Matthew

    2015-01-01

    In recent years there has been an increasing amount of water vapor stable isotope data collected using in-situ instrumentation. A number of papers have characterized the performance of these in-situ analyzers and suggested methods for calibrating raw measurements. The cross-sensitivity of the isotopic measurements on the mixing ratio has been shown to be a major uncertainty and a variety of techniques have been suggested to characterize this inaccuracy. However, most of these are based on relating isotopic ratios to water vapor mixing ratios from in-situ analyzers when the mixing ratio is varied and the isotopic composition kept constant. An additional correction for the span of the isotopic ratio scale is then applied by measuring different isotopic standards. Here we argue that the water vapor cross-sensitivity arises from different instrument responses (span and offset) of the parent H2O isotope and the heavier isotopes, rather than spectral overlap that could cause a true variation in the isotopic ratio with mixing ratio. This is especially relevant for commercial laser optical instruments where absorption lines are well resolved. Thus, the cross-sensitivity determined using more conventional techniques is dependent on the isotopic ratio of the standard used for the characterization, although errors are expected to be small. Consequently, the cross-sensitivity should be determined by characterizing the span and zero offset of each isotope mixing ratio. In fact, this technique makes the span correction for the isotopic ratio redundant. In this work we model the impact of changes in the span and offset of the heavy and light isotopes and illustrate the impact on the cross-sensitivity of the isotopic ratios on water vapor. This clearly shows the importance of determining the zero offset for the two isotopes. The cross-sensitivity of the isotopic ratios on water vapor is then characterized by determining the instrument response for the individual isotopes for a

  9. Measuring adherence to antiretroviral treatment in resource-poor settings: The feasibility of collecting routine data for key indicators

    Directory of Open Access Journals (Sweden)

    Tadeg Hailu

    2010-02-01

    Full Text Available Abstract Background An East African survey showed that among the few health facilities that measured adherence to antiretroviral therapy, practices and definitions varied widely. We evaluated the feasibility of collecting routine data to standardize adherence measurement using a draft set of indicators. Methods Targeting 20 facilities each in Ethiopia, Kenya, Rwanda, and Uganda, in each facility we interviewed up to 30 patients, examined 100 patient records, and interviewed staff. Results In 78 facilities, we interviewed a total of 1,631 patients and reviewed 8,282 records. Difficulties in retrieving records prevented data collection in two facilities. Overall, 94.2% of patients reported perfect adherence; dispensed medicine covered 91.1% of days in a six month retrospective period; 13.7% of patients had a gap of more than 30 days in their dispensed medication; 75.8% of patients attended clinic on or before the date of their next appointment; and 87.1% of patients attended within 3 days. In each of the four countries, the facility-specific median indicators ranged from: 97%-100% for perfect self-reported adherence, 90%-95% of days covered by dispensed medicines, 2%-19% of patients with treatment gaps of 30 days or more, and 72%-91% of appointments attended on time. Individual facilities varied considerably. The percentages of days covered by dispensed medicine, patients with more than 95% of days covered, and patients with a gap of 30 days or more were all significantly correlated with the percentages of patients who attended their appointments on time, within 3 days, or within 30 days of their appointment. Self reported recent adherence in exit interviews was significantly correlated only with the percentage of patients who attended within 3 days of their appointment. Conclusions Field tests showed that data to measure adherence can be collected systematically from health facilities in resource-poor settings. The clinical validity of these

  10. Self-regulated growth of LaVO3 thin films by hybrid molecular beam epitaxy

    International Nuclear Information System (INIS)

    Zhang, Hai-Tian; Engel-Herbert, Roman; Dedon, Liv R.; Martin, Lane W.

    2015-01-01

    LaVO 3 thin films were grown on SrTiO 3 (001) by hybrid molecular beam epitaxy. A volatile metalorganic precursor, vanadium oxytriisopropoxide (VTIP), and elemental La were co-supplied in the presence of a molecular oxygen flux. By keeping the La flux fixed and varying the VTIP flux, stoichiometric LaVO 3 films were obtained for a range of cation flux ratios, indicating the presence of a self-regulated growth window. Films grown under stoichiometric conditions were found to have the largest lattice parameter, which decreased monotonically with increasing amounts of excess La or V. Energy dispersive X-ray spectroscopy and Rutherford backscattering measurements were carried out to confirm film compositions. Stoichiometric growth of complex vanadate thin films independent of cation flux ratios expands upon the previously reported self-regulated growth of perovskite titanates using hybrid molecular beam epitaxy, thus demonstrating the general applicability of this growth approach to other complex oxide materials, where a precise control over film stoichiometry is demanded by the application

  11. Body conscious? Interoceptive awareness, measured by heartbeat perception, is negatively correlated with self-objectification.

    Directory of Open Access Journals (Sweden)

    Vivien Ainley

    Full Text Available BACKGROUND: 'Self-objectification' is the tendency to experience one's body principally as an object, to be evaluated for its appearance rather than for its effectiveness. Within objectification theory, it has been proposed that self-objectification accounts for the poorer interoceptive awareness observed in women, as measured by heartbeat perception. Our study is, we believe, the first specifically to test this relationship. METHODOLOGY/PRINCIPAL FINDINGS: Using a well-validated and reliable heartbeat perception task, we measured interoceptive awareness in women and compared this with their scores on the Self-Objectification Questionnaire, the Self-Consciousness Scale and the Body Consciousness Questionnaire. Interoceptive awareness was negatively correlated with self-objectification. Interoceptive awareness, public body consciousness and private body consciousness together explained 31% of the variance in self-objectification. However, private body consciousness was not significantly correlated with interoceptive awareness, which may explain the many nonsignificant results in self-objectification studies that have used private body consciousness as a measure of body awareness. CONCLUSIONS/SIGNIFICANCE: We propose interoceptive awareness, assessed by heartbeat perception, as a measure of body awareness in self-objectification studies. Our findings have implications for those clinical conditions, in women, which are characterised by self-objectification and low interoceptive awareness, such as eating disorders.

  12. Relationship of body mass index and waist to hip ratio measurement with hypertension in young adult medical students

    International Nuclear Information System (INIS)

    Zafar, S.; Haque, I.U.; Rehman, A.U.

    2007-01-01

    To examine the BMI profile and waist to hip ratio measurements of young adult medical students of Lahore medical and dental college and its relationship with hypertension. All the students of Lahore medical and dental college were asked to undergo physical examination. Height, weight, waist circumference, hip circumference, systolic and diastolic blood pressure were recorded. The partial correlation coefficient was used to quantify the association between BMI and waist-to-hip circumference ratio with systolic and diastolic blood pressure. Linear regression analysis was used to assess the influence of body mass index and waist-to-hip circumference ratio on the variance of systolic and diastolic BP. Mean BMI was 23.24 (SD+-4.31). Descriptive analysis revealed that 103 (21.3%) of the study population were classified as underweight, 251 (52 %) as normal weight, 99 (20.5%) as overweight, and 30 (6.2 %) as obese. Abdominal adiposity, as measured by increased WHR, was present in 56 subjects (11.59 %). Partial correlation controlled for age revealed strong positive correlation between BMI and WHR for males. 7.24% had high systolic blood pressure, minimum systolic BP was 90 while maximum being 160 mmHg. Same was the value for high diastolic blood pressure i.e. 35 (7.24%), range was from 60 to 100mm Hg. Results of the partial correlation coefficient controlled for age, indicated a significant positive correlation between SBP and DBP. Stepwise linear regression analysis controlled for age revealed that both body mass index and waist-to-hip circumference ratio were independently correlated with both systolic and diastolic blood pressures. The present results suggest that prevalence of overweight and obesity among the medical students is higher than in general population. Those with either higher BMI or central adiposity distribution are potential candidates of increased risk of hypertension and cardiovascular disease. (author)

  13. The Spanish version of the Self-Determination Inventory Student Report: application of item response theory to self-determination measurement.

    Science.gov (United States)

    Mumbardó-Adam, C; Guàrdia-Olmos, J; Giné, C; Raley, S K; Shogren, K A

    2018-04-01

    A new measure of self-determination, the Self-Determination Inventory: Student Report (Spanish version), has recently been adapted and empirically validated in Spanish language. As it is the first instrument intended to measure self-determination in youth with and without disabilities, there is a need to further explore and strengthen its psychometric analysis based on item response patterns. Through item response theory approach, this study examined item observed distributions across the essential characteristics of self-determination. The results demonstrated satisfactory to excellent item functioning patterns across characteristics, particularly within agentic action domains. Increased variability across items was also found within action-control beliefs dimensions, specifically within the self-realisation subdomain. These findings further support the instrument's psychometric properties and outline future research directions. © 2017 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  14. Measuring Welfare beyond GDP : 'Objective' and 'Subjective' Indicators in Sweden, 1968-2015

    Directory of Open Access Journals (Sweden)

    Christopher Kullenberg

    2017-10-01

    Full Text Available This article analyses a series of negotiations on how to measure welfare and quality of life in Sweden beyond economic indicators. It departs from a 2015 Government Official Report that advanced a strong recommendation to measure only 'objective indicators' of quality of life, rather than relying on what is referred to as 'subjective indicators' such as life satisfaction and happiness. The assertion of strictly 'objective' indicators falls back on a sociological perspective developed in the 1970s, which conceived of welfare as being measurable as 'levels of living', a framework that came to be called 'the Scandinavian model of welfare research'. However, in the mid-2000s, objective indicators were challenged scientifically by the emerging field of happiness studies, which also found political advocates in Sweden who argued that subjective indicators should become an integral part of measuring welfare. This tension between 'subjective' and 'objective' measurements resulted in a controversy between several actors about what should count as a valuable measurement of welfare. As a consequence, we argue that the creation of such value meters is closely intertwined with how welfare is defined, and by what measures welfare should be carried through.

  15. Process-oriented performance indicators for measuring ecodesign management practices

    DEFF Research Database (Denmark)

    Rodrigues, Vinicius Picanco; Pigosso, Daniela Cristina Antelmi; McAloone, Tim C.

    2016-01-01

    In order to support ecodesign performance measurement from a business perspective, this paper performs an exploration of available process-oriented indicators to be applied to ecodesign management practices. With the Ecodesign Maturity Model as a background framework, a systematic literature review...... coupled with a cross-content analysis was carried out to assign proper indicators to the practices. Results show that the currently available indicators do not fully reflect the characteristics of ecodesign and there is significant room for improving the development of tailor-made indicators....

  16. Broadband measurements of high-frequency electric field levels and exposure ratios determination

    Directory of Open Access Journals (Sweden)

    Vulević Branislav

    2017-01-01

    Full Text Available The exposure of people to high-frequency electromagnetic fields (over 100 kHz that emanate from modern wireless information transmission systems is inevitable in modern times. Due to the rapid development of new technologies, measuring devices and their connection to measuring systems, the first fifteen years of the 21st century are characterized by the appearance of different approaches to measurements. This prompts the need for the assessment of the exposure of people to these fields. The main purpose of this paper is to show how to determine the exposure ratios based on the results of broadband measurements of the high-frequency electric field in the range of 3 MHz to 18 GHz in the environment.

  17. Measuring individual work performance: Identifying and selecting indicators

    NARCIS (Netherlands)

    Koopmans, L.; Bernaards, C.M.; Hildebrandt, V.H.; de Vet, H.C.W.; van der Beek, A.J.

    2014-01-01

    BACKGROUND: Theoretically, individual work performance (IWP) can be divided into four dimensions: task performance, contextual performance, adaptive performance, and counterproductive work behavior. However, there is no consensus on the indicators used to measure these dimensions.

  18. Combining tracer flux ratio methodology with low-flying aircraft measurements to estimate dairy farm CH4 emissions

    Science.gov (United States)

    Daube, C.; Conley, S.; Faloona, I. C.; Yacovitch, T. I.; Roscioli, J. R.; Morris, M.; Curry, J.; Arndt, C.; Herndon, S. C.

    2017-12-01

    Livestock activity, enteric fermentation of feed and anaerobic digestion of waste, contributes significantly to the methane budget of the United States (EPA, 2016). Studies question the reported magnitude of these methane sources (Miller et. al., 2013), calling for more detailed research of agricultural animals (Hristov, 2014). Tracer flux ratio is an attractive experimental method to bring to this problem because it does not rely on estimates of atmospheric dispersion. Collection of data occurred during one week at two dairy farms in central California (June, 2016). Each farm varied in size, layout, head count, and general operation. The tracer flux ratio method involves releasing ethane on-site with a known flow rate to serve as a tracer gas. Downwind mixed enhancements in ethane (from the tracer) and methane (from the dairy) were measured, and their ratio used to infer the unknown methane emission rate from the farm. An instrumented van drove transects downwind of each farm on public roads while tracer gases were released on-site, employing the tracer flux ratio methodology to assess simultaneous methane and tracer gas plumes. Flying circles around each farm, a small instrumented aircraft made measurements to perform a mass balance evaluation of methane gas. In the course of these two different methane quantification techniques, we were able to validate yet a third method: tracer flux ratio measured via aircraft. Ground-based tracer release rates were applied to the aircraft-observed methane-to-ethane ratios, yielding whole-site methane emission rates. Never before has the tracer flux ratio method been executed with aircraft measurements. Estimates from this new application closely resemble results from the standard ground-based technique to within their respective uncertainties. Incorporating this new dimension to the tracer flux ratio methodology provides additional context for local plume dynamics and validation of both ground and flight-based data.

  19. Telemedicine-guided, very low-dose international normalized ratio self-control in patients with mechanical heart valve implants.

    Science.gov (United States)

    Koertke, Heinrich; Zittermann, Armin; Wagner, Otto; Secer, Songuel; Sciangula, Alfonso; Saggau, Werner; Sack, Falk-Udo; Ennker, Jürgen; Cremer, Jochen; Musumeci, Francesco; Gummert, Jan F

    2015-06-01

    To study in patients performing international normalized ratio (INR) self-control the efficacy and safety of an INR target range of 1.6-2.1 for aortic valve replacement (AVR) and 2.0-2.5 for mitral valve replacement (MVR) or double valve replacement (DVR). In total, 1304 patients undergoing AVR, 189 undergoing MVR and 78 undergoing DVR were randomly assigned to low-dose INR self-control (LOW group) (INR target range, AVR: 1.8-2.8; MVR/DVR: 2.5-3.5) or very low-dose INR self-control once a week (VLO group) and twice a week (VLT group) (INR target range, AVR: 1.6-2.1; MVR/DVR: 2.0-2.5), with electronically guided transfer of INR values. We compared grade III complications (major bleeding and thrombotic events; primary end-points) and overall mortality (secondary end-point) across the three treatment groups. Two-year freedom from bleedings in the LOW, VLO, and VLT groups was 96.3, 98.6, and 99.1%, respectively (P = 0.008). The corresponding values for thrombotic events were 99.0, 99.8, and 98.9%, respectively (P = 0.258). The risk-adjusted composite of grade III complications was in the per-protocol population (reference: LOW-dose group) as follows: hazard ratio = 0.307 (95% CI: 0.102-0.926; P = 0.036) for the VLO group and = 0.241 (95% CI: 0.070-0.836; P = 0.025) for the VLT group. The corresponding values of 2-year mortality were = 1.685 (95% CI: 0.473-5.996; P = 0.421) for the VLO group and = 4.70 (95% CI: 1.62-13.60; P = 0.004) for the VLT group. Telemedicine-guided very low-dose INR self-control is comparable with low-dose INR in thrombotic risk, and is superior in bleeding risk. Weekly testing is sufficient. Given the small number of MVR and DVR patients, results are only valid for AVR patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  20. Robustness of two single-item self-esteem measures: cross-validation with a measure of stigma in a sample of psychiatric patients.

    Science.gov (United States)

    Bagley, Christopher

    2005-08-01

    Robins' Single-item Self-esteem Inventory was compared with a single item from the Coopersmith Self-esteem. Although a new scoring format was used, there was good evidence of cross-validation in 83 current and former psychiatric patients who completed Harvey's adapted measure of stigma felt and experienced by users of mental health services. Scores on the two single-item self-esteem measures correlated .76 (p self-esteem in users of mental health services.

  1. Implicit versus explicit measures of self-concept of self-control and their differential predictive power for spontaneous trait-relevant behaviors

    NARCIS (Netherlands)

    Huntjens, Rafaele J. C.; Rijkeboer, Marleen M.; Krakau, Andrej; de Jong, Peter J.

    BACKGROUND AND OBJECTIVES: Low trait self-control constitutes a core criterion in various psychiatric disorders. Personality traits such as low self-control are mostly indexed by self-report measures. However, several theorists emphasized the importance of differentiating between explicit and

  2. Measurements of isomeric yield ratios of fission products from proton-induced fission on natU and 232Th via direct ion counting

    Directory of Open Access Journals (Sweden)

    Rakopoulos Vasileios

    2017-01-01

    Full Text Available Independent isomeric yield ratios (IYR of 81Ge, 96Y, 97Y, 97Nb, 128Sn and 130Sn have been determined in the 25 MeV proton-induced fission of natU and 232Th. The measurements were performed at the Ion Guide Isotope Separator On-Line (IGISOL facility at the University of Jyväskylä. A direct ion counting measurement of the isomeric fission yield ratios was accomplished for the first time, registering the fission products in less than a second after their production. In addition, the IYRs of natU were measured by means of γ-spectroscopy in order to verify the consistency of the recently upgraded experimental setup. From the obtained results, indications of a dependence of the production rate on the fissioning system can be noticed. These data were compared with data available in the literature, whenever possible. Using the TALYS code and the experimentally obtained IYRs, we also deduced the average angular momentum of the fission fragments after scission.

  3. Can the triple Higgs self-coupling be measured at future colliders?

    International Nuclear Information System (INIS)

    Miller, D.J.

    2000-01-01

    The experimental reconstruction of the Higgs self-energy potential is essential to a verification of the Higgs boson's role in spontaneous electroweak symmetry breaking. The first step towards this goal, the measurement of the triple Higgs self-coupling, can possibly be accomplished at the next generation of linear colliders. Here we discuss the most promising channels at future hadron and e + e - colliders and present background studies to evaluate the feasibility of its measurement

  4. Measuring individual work performance: identifying and selecting indicators

    NARCIS (Netherlands)

    Koopmans, L.; Bernaards, C.M.; Hildebrandt, V.H.; Vet, H.C de; Beek, A.J. van der

    2014-01-01

    BACKGROUND: Theoretically, individual work performance (IWP) can be divided into four dimensions: task performance, contextual performance, adaptive performance, and counterproductive work behavior. However, there is no consensus on the indicators used to measure these dimensions. OBJECTIVE: This

  5. One-Dimensional-Ratio Measures of Atrophy Progression in Multiple Sclerosis as Evaluated by Longitudinal Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Martola, J.; Wiberg Kristoffersen, M.; Aspelin, P.; Stawiarz, L.; Fredrikson, S.; Hillert, J.; Bergstroem, J.; Flodmark, O.

    2009-01-01

    Background: For decades, normalized one-dimensional (1D) measures have been used in the evaluation of brain atrophy. In multiple sclerosis (MS), the use of normalized linear measures over longitudinal follow-up remains insufficiently documented. Purpose: To evaluate the association between different regional atrophy measures and disability in MS patients over four decades in a longitudinal cross-sectional study. Material and Methods: 37 consecutively selected MS patients were included. At baseline, patients had a range of disease duration (1-33 years) and age (24-65 years). Each patient was followed by magnetic resonance imaging (MRI) for a mean of 9.25 years (range 7.3-10 years). Four 1D measures were applied at three time points on axial 5-mm T1-weighted images. Three clinical MS subgroups were represented: relapsing-remitting MS (RRMS), secondary progressive MS (SPMS), and primary progressive MS (PPMS). Results: There were significant changes in all 1D ratios during follow-up. The Evans ratio (ER) and the bifrontal ratio (BFR) were associated with the development of disability. Changes of ER and BFR reflected more aggressive disease progression, as expressed by MS severity score (MSSS). Conclusion: All four normalized ratios showed uniform atrophy progression, suggesting a consistent rate of atrophy over long-term disease duration independent of MS course. Disability status correlated with 1D measures, suggesting that serial evaluation of Evans and bifrontal ratios might contribute to the radiological evaluation of MS patients

  6. Stable Carbon Isotope Ratio (δ13C Measurement of Graphite Using EA-IRMS System

    Directory of Open Access Journals (Sweden)

    Andrius Garbaras

    2015-06-01

    Full Text Available δ13C values in non-irradiated natural graphite were measured. The measurements were carried out using an elemental analyzer combined with stable isotope ratio mass spectrometer (EA-IRMS. The samples were prepared with ground and non-ground graphite, the part of which was mixed with Mg (ClO42. The best combustion of graphite in the oxidation furnace of the elemental analyzer was achieved when the amount of pulverized graphite ranged from 200 to 490 µg and the mass ratio C:Mg(ClO42 was approximately 1:10. The method for the graphite burning avoiding the isotope fractionation is proposed.DOI: http://dx.doi.org/10.5755/j01.ms.21.2.6873

  7. Shape coexistence from lifetime and branching-ratio measurements in "6"8","7"0Ni

    International Nuclear Information System (INIS)

    Crider, B. P.; Prokop, C. J.; Liddick, S. N.; Al-Shudifat, M.; Ayangeakaa, A. D.

    2016-01-01

    Shape coexistence near closed-shell nuclei, whereby states associated with deformed shapes appear at relatively low excitation energy alongside spherical ones, is indicative of the rapid change in structure that can occur with the addition or removal of a few protons or neutrons. Near "6"8Ni (Z=28, N=40), the identification of shape coexistence hinges on hitherto undetermined transition rates to and from low-energy 0+ states. In "6"8","7"0Ni, new lifetimes and branching ratios have been measured. These data enable quantitative descriptions of the 0+ states through the deduced transition rates and serve as sensitive probes for characterizing their nuclear wave functions. The results are compared to, and consistent with, large-scale shell-model calculations which predict shape coexistence. With the firm identification of this phenomenon near "6"8Ni, shape coexistence is now observed in all currently accessible regions of the nuclear chart with closed proton shells and mid-shell neutrons.

  8. Study on strontium isotope abundance-ratio measurements by using a 13-MeV proton beam

    Science.gov (United States)

    Jeong, Cheol-Ki; Jang, Han; Lee, Goung-Jin

    2016-09-01

    The Rb-Sr dating method is used in dating Paleozoic and Precambrian rocks. This method measures the 87Rb and the 87Sr concentrations by using thermal ionization mass spectrometry (TIMS) [J. Hefne et al., Inter. J. Phys. Sci. 3(1), 28 (2008)]. In addition, it calculates the initial 87Sr/86Sr ratio to increase the reliability of Rb-Sr dating. In this study, the 87Sr/86Sr ratio was measured by using a 13-MeV proton accelerator. Proton kinetic energies are in the range of tens of megaelectronvolts, and protons have large absorption cross-sections for ( p, n) reactions with most substances. After absorbing a proton with such a high kinetic energy, an element is converted into a nuclide with its atomic number increased by one via nuclear transmutation. These nuclides usually have short half-lives and return to the original state through radioactive decay. When a strontium sample is irradiated with protons, nuclear transmutation occurs; thus, the strontium isotope present in the sample changes to a yttrium isotope, which is an activated radioisotope. Based on this, the 87Sr/86Sr ratio was calculated by analyzing the gamma-rays emitted by each yttrium isotope. The KIRAMS-13 cyclotron at the Cyclotron Center of Chosun University, where 13-MeV protons can be extracted, was utilized in our experiment. The 87Sr/86Sr isotope ratio was computed for samples irradiated with these protons, and the result was similar to the isotope ratio for the Standard Reference Material, i.e., 98.2 ± 3.4%. As part of the analysis, proton activation analyses were performed using 13-MeV protons, and the experimental results of this research suggest a possible approach for measuring the strontium-isotope abundance ratio of samples.

  9. A measurement of the branching ratio for the Σ+ → pγ decay

    International Nuclear Information System (INIS)

    Hessey, N.P.; Lowe, J.; Booth, E.C.; Gall, K.P.; McIntyre, E.K.; Miller, J.P.; Roberts, B.L.; Whitehouse, D.A.; Fickinger, W.J.; Robinson, D.K.; Hasinoff, M.D.; Measday, D.F.; Noble, A.J.; Horvath, D.; Salomon, M.

    1989-01-01

    We have measured the weak radiative decay branching ratio (Σ + → pγ)/(Σ + → pπ 0 ). The experiment was carried out at Brookhaven National Laboratory using a low-energy separated K - beam stopping in liquid hydrogen. The Σ + was tagged by observing the pion from K - p → Σ + π - in a range telescope, and the gamma was detected in a segmented NaI detector. The result is (2.81 ± 0.39 +0.21 0.43 ) x 10 -3 , which is consistent with previous measurements. This corresponds to a branching ratio for (Σ + → pγ)/(Σ + → all) of (1.45 ± 0.20 +0.11 0.22 ) x 10 -3 , where the quoted errors are statistical and systematic, respectively. A total of 408 signal events were observed, doubling the previous world total. (orig.)

  10. Accurate branching ratio measurements in 23Na(p,γ)24Mg

    International Nuclear Information System (INIS)

    Boydell, S.G.; Sargood, D.G.

    1975-01-01

    The reaction 23 Na(p,γ) 24 Mg has been investigated in the proton energy range 0.3-1.75 MeV. Gamma ray spectra were measured for 22 resonances with Ge(Li) detectors which were carefully calibrated for relative peak efficiencies. Allowance was made for the effect of anisotropies in all the emitted γ-rays. The spectra have been analysed to give branching ratios for bound and unbound levels. (author)

  11. pedometer-measured physical activity, self-reported physical activity

    African Journals Online (AJOL)

    between self-reported and pedometer-measured physical activity was also determined. Results. Average ... Methods. This was a cross-sectional study among employed South African adults. Participant ... acquired information on physical activity habits. Questions ..... How many days of monitoring predict physical activity and ...

  12. Measurement of the antineutrino to neutrino charged-current interaction cross section ratio in MINERvA

    Science.gov (United States)

    Ren, L.; Aliaga, L.; Altinok, O.; Bellantoni, L.; Bercellie, A.; Betancourt, M.; Bodek, A.; Bravar, A.; Budd, H.; Cai, T.; Carneiro, M. F.; da Motta, H.; Devan, J.; Dytman, S. A.; Díaz, G. A.; Eberly, B.; Endress, E.; Felix, J.; Fields, L.; Fine, R.; Gago, A. M.; Galindo, R.; Gallagher, H.; Ghosh, A.; Golan, T.; Gran, R.; Han, J. Y.; Harris, D. A.; Hurtado, K.; Kiveni, M.; Kleykamp, J.; Kordosky, M.; Le, T.; Maher, E.; Manly, S.; Mann, W. A.; Marshall, C. M.; Martinez Caicedo, D. A.; McFarland, K. S.; McGivern, C. L.; McGowan, A. M.; Messerly, B.; Miller, J.; Mislivec, A.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Norrick, A.; Nuruzzaman, Paolone, V.; Park, J.; Patrick, C. E.; Perdue, G. N.; Ramírez, M. A.; Ransome, R. D.; Ray, H.; Rimal, D.; Rodrigues, P. A.; Ruterbories, D.; Schellman, H.; Solano Salinas, C. J.; Sultana, M.; Sánchez Falero, S.; Valencia, E.; Walton, T.; Wolcott, J.; Wospakrik, M.; Yaeggy, B.; MinerνA Collaboration

    2017-04-01

    We present measurements of the neutrino and antineutrino total charged-current cross sections on carbon and their ratio using the MINERvA scintillator-tracker. The measurements span the energy range 2-22 GeV and were performed using forward and reversed horn focusing modes of the Fermilab low-energy NuMI beam to obtain large neutrino and antineutrino samples. The flux is obtained using a subsample of charged-current events at low hadronic energy transfer along with precise higher energy external neutrino cross section data overlapping with our energy range between 12-22 GeV. We also report on the antineutrino-neutrino cross section ratio, RCC , which does not rely on external normalization information. Our ratio measurement, obtained within the same experiment using the same technique, benefits from the cancellation of common sample systematic uncertainties and reaches a precision of ˜5 % at low energy. Our results for the antineutrino-nucleus scattering cross section and for RCC are the most precise to date in the energy range Eν<6 GeV .

  13. The value of an implicit self-associative measure specific to core beliefs of depression

    NARCIS (Netherlands)

    Lemmens, L.H.J.M.; Roefs, A.; Arntz, A.; van Teeseling, H.C.; Peeters, F.; Huibers, M.J.H.

    2014-01-01

    Background and objectives The present study examined differences in explicit and implicit measures of self-esteem between depressed patients and healthy controls using an indirect measurement procedure especially adapted to measure self-esteem aspects of core beliefs of depression. Furthermore, we

  14. The value of an implicit self-associative measure specific to core beliefs of depression

    NARCIS (Netherlands)

    Lemmens, L.H.J.M.; Roefs, A.; Arntz, A.; van Teeseling, H.C.; Peeters, F.; Huibers, M.J.H.

    2014-01-01

    Background and objectives: The present study examined differences in explicit and implicit measures of self-esteem between depressed patients and healthy controls using an indirect measurement procedure especially adapted to measure self-esteem aspects of core beliefs of depression. Furthermore, we

  15. Measuring Institutions: Indicators of Political and Property Rights in Malawi

    Science.gov (United States)

    Fedderke, Johannes; Garlick, Julia

    2012-01-01

    This paper constructs a new set of institutional indicators for Malawi. We develop indicators of political rights, of freehold, traditional (communitarian) and intellectual property rights, based on the Malawian legislative framework. In exploring the association between our rights measures and a range of indicators of socio-economic development,…

  16. Definition of Time Induction of Self-Ignition of the Substance on the Prognostic Extrapolation Depending on the Basis of Indicators Fire and Explosion Hazard

    International Nuclear Information System (INIS)

    Sechin, A; Kyrmakova, O; Osipenko, S

    2016-01-01

    In this article the research directed on development of a technique of definition of time of induction of the self-ignition of substances and materials which is an indicator of the beginning of development of an emergency is conducted. The experiment consisting in supervision over process of self-ignition of coal and oil deposits was the basis for research. On the basis of experimental data the curve expressing analytic - expected dependence of size of temperature of ignition on induction time was constructed. Proceeding from graphical representation of process, functional dependence of time of induction on a temperature indicator was received: y = 16920 • x 0 537 . By means of known indicators of such substances as bitumen oil oxidized (the combustible solid substance received by oxidation of residual product of oil refining) and tar oil (the combustible solid substance which is residual product of oil refining) and the received algorithm, verification of reliability of the received dependence and a technique of definition of time of induction of spontaneous ignition of deposits of oil in general was carried out. The practical importance of the conducted research is that having data on time of induction of process of self-ignition, by means of preventive measures becomes possible to avoid and prevent accidents in oil and oil processing branches, at the same time loss of property and loss of human life. (paper)

  17. Children of the closet: a measurement of the anxiety and self-esteem of children raised by a non-disclosed homosexual or bisexual parent.

    Science.gov (United States)

    Murray, Paul D; McClintock, Karen

    2005-01-01

    This research examined whether a parent's non-disclosure of his or her homosexual or bisexual orientation within the family unit negatively affects self-esteem and anxiety in children, as measured in adulthood. Thirty-six subjects indicated that they had not known of their parent's sexual orientation until an average age of sixteen for the children of lesbian or bisexual mothers, and twenty-two for the children of gay or bisexual fathers. This group's scores on the Rosenberg Self-Esteem Scale, the Marlowe Crowne Social Desirabilty Scale and the State-Trait Anxiety Scale were compared to scores obtained by sixty-three participants who did not have a homosexual/bisexual parent. The number of years a secretive environment surrounded the child was measured, as were participants' attitudes about the secret sexual identity. Although the study did not find that adults previously raised with a closeted parent had significantly higher levels of anxiety or lower levels of self-esteem, results indicated that those who had been raised as children with non-disclosed lesbian mothers showed a significantly higher level of self-esteem than participants with heterosexual parents. Implications of the findings for the targeted population are discussed.

  18. Comparison between young male drivers' self-assessed and objectively measured driving skills

    DEFF Research Database (Denmark)

    Martinussen, Laila Marianne; Møller, Mette; Prato, Carlo Giacomo

    2017-01-01

    Self-assessment of skills is a self-generated feedback process that contributes to confidence in one's skills. The higher one's self-assessed skills, the more likely one is to feel competent a particular domain thereby influencing the related behaviors. Drivers' self-assessed driving skills...... are not always accurate, which may cause serious problems such as underestimation of risk, reckless driving and accidents. Most previous research on self-assessment of driving skills did not compare self-reported skills to objectively measured driving skills, so the aim of this study was to test the accuracy...

  19. Self-Report Measures of Parent-Adolescent Attachment and Separation-Individuation: A Selective Review.

    Science.gov (United States)

    Lopez, Frederick G.; Gover, Mark R.

    1993-01-01

    Reviews and critiques three self-report measures of parent-adolescent attachment (Parental Bonding Instrument, Parental Attachment Questionnaire, Inventory of Parent and Peer Attachment) and three self-report measures of parent-adolescent separation-individuation (Psychological Separation Inventory, Personal Authority in the Family System…

  20. Developing Emergency Room Key Performance Indicators: What to Measure and Why Should We Measure It?

    Science.gov (United States)

    Khalifa, Mohamed; Zabani, Ibrahim

    2016-01-01

    Emergency Room (ER) performance has been a timely topic for both healthcare practitioners and researchers. King Faisal Specialist Hospital and Research Center, Saudi Arabia worked on developing a comprehensive set of KPIs to monitor, evaluate and improve the performance of the ER. A combined approach using quantitative and qualitative methods was used to collect and analyze the data. 34 KPIs were developed and sorted into the three components of the ER patient flow model; input, throughput and output. Input indicators included number and acuity of ER patients, patients leaving without being seen and revisit rates. Throughput indicators included number of active ER beds, ratio of ER patients to ER staff and the length of stay including waiting time and treatment time. The turnaround time of supportive services, such as lab, radiology and medications, were also included. Output indicators include boarding time and available hospital beds, ICU beds and patients waiting for admission.

  1. Association of Self-Efficacy and Self-Regulation with Nutrition and Exercise Behaviors in a Community Sample of Adults.

    Science.gov (United States)

    Shieh, Carol; Weaver, Michael T; Hanna, Kathleen M; Newsome, Kathleen; Mogos, Mulubrhan

    2015-01-01

    This study examined the association of self-efficacy and self-regulation with nutrition and exercise behaviors. The study used a cross-sectional design and included 108 participants (54 men, 54 women). Nutrition behaviors (fruit/vegetable consumption, dinner cooking, and restaurant eating) and exercise were measured using total days in last week a behavior was reported. Instruments measuring self-efficacy and self-regulation demonstrated excellent Cronbach's alphas (.93-.95). Path analysis indicated only fruit/vegetable consumption and exercise were associated with self-efficacy and self-regulation. Self-regulation showed direct association with fruit/vegetable consumption and exercise, but self-efficacy had direct association only with exercise. Self-efficacy and self-regulation should be strategically used to promote health behaviors.

  2. Measurement of L3 subshell absorption jump ratios and jump factors for high Z elements using EDXRF technique

    International Nuclear Information System (INIS)

    Kaçal, M.R.

    2014-01-01

    Energy dispersive X-ray fluorescence technique (EDXRF) has been employed for measuring L 3 -subshell absorption jump ratios, r L 3 and jump factors, J L 3 for high Z elements. Jump factors and jump ratios for these elements have been determined by measuring L 3 subshell fluorescence parameters such as L 3 subshell X-ray production cross section σ L 3 , L 3 subshell fluorescence yield, ω L 3 , total L 3 subshell and higher subshells photoionization cross section σ L T . Measurements were performed using a Cd-109 radioactive point source and an Si(Li) detector in direct excitation experimental geometry. Measured values for jump factors and jump ratios have been compared with theoretically calculated and other experimental values. - Highlights: • This paper regards L 3 subshell absorption jump ratios and jump factors using the EDXRF method. • These parameters were measured using a new method. • This method is more useful than other methods which require much effort. • Results are in good agreement with theoretical and experimental values

  3. Measurement of the form factor ratios in semileptonic decays of charm mesons

    Energy Technology Data Exchange (ETDEWEB)

    Zaliznyak, Renata [Stanford Univ., CA (United States)

    1998-05-01

    I have measured the form factor ratios r2 = A2 (0)/A1 (0) and rV = V (0)/A1 (0) in the semileptonic charm meson decay D+ → $\\bar{K}$*0 e+ve from data collected by the Fermilab E791 collaboration. Form factors are introduced in the calculation of the hadronic current in semileptonic decays of strange, charm, or bottom mesons, such as D+ → $\\bar{K}$*0 e+ ve . Semileptonic decays provide insight into quark coupling to the W boson since the leptonic and hadronic amplitudes in the Feynman diagram for the decay are completely separate. There are no strong interactions between the final state leptons and quarks. A number of theoretical models predict the values of the form factors for D+ → $\\bar{K}$*0 e+ ve , though there is a large range of predictions. E791 is a hadroproduction experiment that recorded over 20 billion interactions with a 500 GeV π- beam incident on five thin targets during the 1991-92 Fermilab fixed-target run. Approximately 3000 D+ → $\\bar{K}$*0 e+ ve decays are fully reconstructed. In order to extract the form factor ratios from the data, I implement a multidimensional unbinned maximum likelihood fit with a large sample of simulated (Monte Carlo) D+ → $\\bar{K}$*0 e+ve events. The large E791 data sample provides the most precise measurement of the form factor ratios to date. The measured values for the form factor ratios are r2 = 0.71 ± 0.08 ± 0.09 and rV = 1.84 ± 0.11 ±} 0.08. These results are in good agreement with some Lattice Gauge calculations. However the agreement with quark model predictions is not as good.

  4. Perceptions of self-concept and self-presentation by procrastinators: further evidence.

    Science.gov (United States)

    Ferrari, Joseph R; Díaz-Morales, Juan Francisco

    2007-05-01

    Two samples of university students completed self-report measures of chronic procrastination and either self-concept variables (Sample 1, n = 233) or self-presentational styles (Sample 2, n = 210). Results indicated that procrastination was significantly related to a self-concept of oneself as dominated by issues related to task performance, and to self-presentation strategies that reflected a person as continually justifying and excusing task delays and being "needy" of others' approval. It seems that men and women procrastinate in order to improve their social standing by making their accomplishments seem greater than they really are.

  5. Measures of effect size for chi-squared and likelihood-ratio goodness-of-fit tests.

    Science.gov (United States)

    Johnston, Janis E; Berry, Kenneth J; Mielke, Paul W

    2006-10-01

    A fundamental shift in editorial policy for psychological journals was initiated when the fourth edition of the Publication Manual of the American Psychological Association (1994) placed emphasis on reporting measures of effect size. This paper presents measures of effect size for the chi-squared and the likelihood-ratio goodness-of-fit statistic tests.

  6. Nonlinear refractive index measurements and self-action effects in Roselle-Hibiscus Sabdariffa solutions

    Science.gov (United States)

    Henari, F. Z.; Al-Saie, A.

    2006-12-01

    We report the observation of self-action phenomena, such as self-focusing, self-defocusing, self-phase modulation and beam fanning in Roselle-Hibiscus Sabdariffa solutions. This material is found to be a new type of natural nonlinear media, and the nonlinear reflective index coefficient has been determined using a Z-scan technique and by measuring the critical power for the self-trapping effect. Z-scan measurements show that this material has a large negative nonlinear refractive index, n 2 = 1 × 10-4 esu. A comparison between the experimental n 2 values and the calculated thermal value for n 2 suggests that the major contribution to nonlinear response is of thermal origin.

  7. An impedance bridge measuring the capacitance ratio in the high frequency range up to 1 MHz

    International Nuclear Information System (INIS)

    Kim, Dan Bee; Lee, Hyung Kew; Kim, Wan-Seop

    2017-01-01

    This paper describes a 2-terminal-pair impedance bridge, measuring the capacitance ratio in the high frequency range up to 1 MHz. The bridge was configured with two voltage sources and a phase control unit which enabled the bridge balance by synchronizing the voltage sources with an enhanced phase resolution. Without employing the transformers such as inductive voltage divider, injection and detection transformers, etc, the bridge system is quite simple to set up, and the balance procedure is quick and easy. Using this dual-source coaxial bridge, the 1:1 and 10:1 capacitance ratios were measured with 1 pF–1 nF capacitors in the frequency range from 1 kHz to 1 MHz. The measurement values obtained by the dual-source bridge were then compared with reference values measured using a commercial precision capacitance bridge of AH2700A, the Z -matrix method developed by ourselves, and the 4-terminal-pair coaxial bridge by the Czech Metrological Institute. All the measurements agreed within the reference uncertainty range of an order of 10 −6 –10 −5 , proving the bridge ability as a trustworthy tool for measuring the capacitance ratio in the high frequency range. (paper)

  8. Measurement of $V^0$ production ratios in $pp$ collisions at $\\sqrt{s}$ = 0.9 and 7 TeV

    CERN Document Server

    Aaij, R.; Adinolfi, M.; Adrover, C.; Affolder, A.; Ajaltouni, Z.; Albrecht, J.; Alessio, F.; Alexander, M.; Alkhazov, G.; Alvarez Cartelle, P.; Alves Jr, A.A.; Amato, S.; Amhis, Y.; Anderson, J.; Appleby, R.B.; Aquines Gutierrez, O.; Arrabito, L.; Artamonov, A.; Artuso, M.; Aslanides, E.; Auriemma, G.; Bachmann, S.; Back, J.J.; Bailey, D.S.; Balagura, V.; Baldini, W.; Barlow, R.J.; Barschel, C.; Barsuk, S.; Barter, W.; Bates, A.; Bauer, C.; Bauer, Th.; Bay, A.; Bediaga, I.; Belous, K.; Belyaev, I.; Ben-Haim, E.; Benayoun, M.; Bencivenni, G.; Benson, S.; Bernet, R.; Bettler, M.O.; van Beuzekom, M.; Bien, A.; Bifani, S.; Bizzeti, A.; Bjornstad, P.M.; Blake, T.; Blanc, F.; Blanks, C.; Blouw, J.; Blusk, S.; Bobrov, A.; Bocci, V.; Bondar, A.; Bondar, N.; Bonivento, W.; Borghi, S.; Borgia, A.; Bowcock, T.J.V.; Bozzi, C.; Brambach, T.; van den Brand, J.; Bressieux, J.; Brett, D.; Brisbane, S.; Britsch, M.; Britton, T.; Brook, N.H.; Buchler-Germann, A.; Burducea, I.; Bursche, A.; Buytaert, J.; Cadeddu, S.; Caicedo Carvajal, J.M.; Callot, O.; Calvi, M.; Calvo Gomez, M.; Camboni, A.; Campana, P.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carson, L.; Carvalho Akiba, K.; Casse, G.; Cattaneo, M.; Charles, M.; Charpentier, Ph.; Chiapolini, N.; Cid Vidal, X.; Ciezarek, G.; Clarke, P.E.L.; Clemencic, M.; Cliff, H.V.; Closier, J.; Coca, C.; Coco, V.; Cogan, J.; Collins, P.; Constantin, F.; Conti, G.; Contu, A.; Coombes, M.; Corti, G.; Cowan, G.A.; Currie, R.; D'Almagne, B.; D'Ambrosio, C.; David, P.; De Bonis, I.; De Capua, S.; De Cian, M.; De Lorenzi, F.; De Miranda, J.M.; De Paula, L.; De Simone, P.; Decamp, D.; Deckenhoff, M.; Degaudenzi, H.; Deissenroth, M.; Del Buono, L.; Deplano, C.; Deschamps, O.; Dettori, F.; Dickens, J.; Dijkstra, H.; Diniz Batista, P.; Dossett, D.; Dovbnya, A.; Dupertuis, F.; Dzhelyadin, R.; Eames, C.; Easo, S.; Egede, U.; Egorychev, V.; Eidelman, S.; van Eijk, D.; Eisele, F.; Eisenhardt, S.; Ekelhof, R.; Eklund, L.; Elsasser, Ch.; d'Enterria, D.G.; Esperante Pereira, D.; Esteve, L.; Falabella, A.; Fanchini, E.; Farber, C.; Fardell, G.; Farinelli, C.; Farry, S.; Fave, V.; Fernandez Albor, V.; Ferro-Luzzi, M.; Filippov, S.; Fitzpatrick, C.; Fontana, M.; Fontanelli, F.; Forty, R.; Frank, M.; Frei, C.; Frosini, M.; Furcas, S.; Gallas Torreira, A.; Galli, D.; Gandelman, M.; Gandini, P.; Gao, Y.; Garnier, J-C.; Garofoli, J.; Garra Tico, J.; Garrido, L.; Gaspar, C.; Gauvin, N.; Gersabeck, M.; Gershon, T.; Ghez, Ph.; Gibson, V.; Gligorov, V.V.; Gobel, C.; Golubkov, D.; Golutvin, A.; Gomes, A.; Gordon, H.; Grabalosa Gandara, M.; Graciani Diaz, R.; Granado Cardoso, L.A.; Grauges, E.; Graziani, G.; Grecu, A.; Gregson, S.; Gui, B.; Gushchin, E.; Guz, Yu.; Gys, T.; Haefeli, G.; Haen, C.; Haines, S.C.; Hampson, T.; Hansmann-Menzemer, S.; Harji, R.; Harnew, N.; Harrison, J.; Harrison, P.F.; He, J.; Heijne, V.; Hennessy, K.; Henrard, P.; Hernando Morata, J.A.; van Herwijnen, E.; Hofmann, W.; Holubyev, K.; Hopchev, P.; Hulsbergen, W.; Hunt, P.; Huse, T.; Huston, R.S.; Hutchcroft, D.; Hynds, D.; Iakovenko, V.; Ilten, P.; Imong, J.; Jacobsson, R.; Jaeger, A.; Jahjah Hussein, M.; Jans, E.; Jansen, F.; Jaton, P.; Jean-Marie, B.; Jing, F.; John, M.; Johnson, D.; Jones, C.R.; Jost, B.; Kandybei, S.; Karacson, M.; Karbach, T.M.; Keaveney, J.; Kerzel, U.; Ketel, T.; Keune, A.; Khanji, B.; Kim, Y.M.; Knecht, M.; Koblitz, S.; Koppenburg, P.; Kozlinskiy, A.; Kravchuk, L.; Kreplin, K.; Kreps, M.; Krocker, G.; Krokovny, P.; Kruse, F.; Kruzelecki, K.; Kucharczyk, M.; Kukulak, S.; Kumar, R.; Kvaratskheliya, T.; La Thi, V.N.; Lacarrere, D.; Lafferty, G.; Lai, A.; Lambert, D.; Lambert, R.W.; Lanciotti, E.; Lanfranchi, G.; Langenbruch, C.; Latham, T.; Le Gac, R.; van Leerdam, J.; Lees, J.P.; Lefevre, R.; Leflat, A.; Lefrancois, J.; Leroy, O.; Lesiak, T.; Li, L.; Li, Y.Y.; Li Gioi, L.; Lieng, M.; Lindner, R.; Linn, C.; Liu, B.; Liu, G.; Lopes, J.H.; Lopez Asamar, E.; Lopez-March, N.; Luisier, J.; Machefert, F.; Machikhiliyan, I.V.; Maciuc, F.; Maev, O.; Magnin, J.; Malde, S.; Mamunur, R.M.D.; Manca, G.; Mancinelli, G.; Mangiafave, N.; Marconi, U.; Marki, R.; Marks, J.; Martellotti, G.; Martens, A.; Martin, L.; Martin Sanchez, A.; Martinez Santos, D.; Massafferri, A.; Mathe, Z.; Matteuzzi, C.; Matveev, M.; Maurice, E.; Maynard, B.; Mazurov, A.; McGregor, G.; McNulty, R.; Mclean, C.; Meissner, M.; Merk, M.; Merkel, J.; Messi, R.; Miglioranzi, S.; Milanes, D.A.; Minard, M.N.; Monteil, S.; Moran, D.; Morawski, P.; Morris, J.V.; Mountain, R.; Mous, I.; Muheim, F.; Muller, K.; Muresan, R.; Muryn, B.; Musy, M.; Naik, P.; Nakada, T.; Nandakumar, R.; Nardulli, J.; Nasteva, I.; Nedos, M.; Needham, M.; Neufeld, N.; Nguyen-Mau, C.; Nicol, M.; Nies, S.; Niess, V.; Nikitin, N.; Oblakowska-Mucha, A.; Obraztsov, V.; Oggero, S.; Ogilvy, S.; Okhrimenko, O.; Oldeman, R.; Orlandea, M.; Otalora Goicochea, J.M.; Owen, P.; Pal, B.; Palacios, J.; Palutan, M.; Panman, J.; Papanestis, A.; Pappagallo, M.; Parkes, C.; Parkinson, C.J.; Passaleva, G.; Patel, G.D.; Patel, M.; Paterson, S.K.; Patrick, G.N.; Patrignani, C.; Pavel-Nicorescu, C.; Pazos Alvarez, A.; Pellegrino, A.; Penso, G.; Pepe Altarelli, M.; Perazzini, S.; Perego, D.L.; Perez Trigo, E.; Perez-Calero Yzquierdo, A.; Perret, P.; Perrin-Terrin, M.; Pessina, G.; Petrella, A.; Petrolini, A.; Pie Valls, B.; Pietrzyk, B.; Pilar, T.; Pinci, D.; Plackett, R.; Playfer, S.; Plo Casasus, M.; Polok, G.; Poluektov, A.; Polycarpo, E.; Popov, D.; Popovici, B.; Potterat, C.; Powell, A.; Pree, T.du; Prisciandaro, J.; Pugatch, V.; Puig Navarro, A.; Qian, W.; Rademacker, J.H.; Rakotomiaramanana, B.; Raniuk, I.; Raven, G.; Redford, S.; Reid, M.M.; Reis, A.C.dos; Ricciardi, S.; Rinnert, K.; Roa Romero, D.A.; Robbe, P.; Rodrigues, E.; Rodrigues, F.; Rodriguez Perez, P.; Rogers, G.J.; Romanovsky, V.; Rouvinet, J.; Ruf, T.; Ruiz, H.; Sabatino, G.; Saborido Silva, J.J.; Sagidova, N.; Sail, P.; Saitta, B.; Salzmann, C.; Sannino, M.; Santacesaria, R.; Santinelli, R.; Santovetti, E.; Sapunov, M.; Sarti, A.; Satriano, C.; Satta, A.; Savrie, M.; Savrina, D.; Schaack, P.; Schiller, M.; Schleich, S.; Schmelling, M.; Schmidt, B.; Schneider, O.; Schopper, A.; Schune, M.H.; Schwemmer, R.; Sciubba, A.; Seco, M.; Semennikov, A.; Senderowska, K.; Sepp, I.; Serra, N.; Serrano, J.; Seyfert, P.; Shao, B.; Shapkin, M.; Shapoval, I.; Shatalov, P.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, O.; Shevchenko, V.; Shires, A.; Silva Coutinho, R.; Skottowe, H.P.; Skwarnicki, T.; Smith, A.C.; Smith, N.A.; Sobczak, K.; Soler, F.J.P.; Solomin, A.; Soomro, F.; Souza De Paula, B.; Spaan, B.; Sparkes, A.; Spradlin, P.; Stagni, F.; Stahl, S.; Steinkamp, O.; Stoica, S.; Stone, S.; Storaci, B.; Straticiuc, M.; Straumann, U.; Styles, N.; Swientek, S.; Szczekowski, M.; Szczypka, P.; Szumlak, T.; T'Jampens, S.; Teodorescu, E.; Teubert, F.; Thomas, C.; Thomas, E.; van Tilburg, J.; Tisserand, V.; Tobin, M.; Topp-Joergensen, S.; Tran, M.T.; Tsaregorodtsev, A.; Tuning, N.; Ukleja, A.; Urquijo, P.; Uwer, U.; Vagnoni, V.; Valenti, G.; Vazquez Gomez, R.; Vazquez Regueiro, P.; Vecchi, S.; Velthuis, J.J.; Veltri, M.; Vervink, K.; Viaud, B.; Videau, I.; Vilasis-Cardona, X.; Visniakov, J.; Vollhardt, A.; Voong, D.; Vorobyev, A.; Voss, H.; Wacker, K.; Wandernoth, S.; Wang, J.; Ward, D.R.; Webber, A.D.; Websdale, D.; Whitehead, M.; Wiedner, D.; Wiggers, L.; Wilkinson, G.; Williams, M.P.; Williams, M.; Wilson, F.F.; Wishahi, J.; Witek, M.; Witzeling, W.; Wotton, S.A.; Wyllie, K.; Xie, Y.; Xing, F.; Yang, Z.; Young, R.; Yushchenko, O.; Zavertyaev, M.; Zhang, L.; Zhang, W.C.; Zhang, Y.; Zhelezov, A.; Zhong, L.; Zverev, E.

    2011-01-01

    The $\\bar{\\Lambda} / \\Lambda$ and $\\bar{\\Lambda} / K^0_\\mathrm{S}$ production ratios are measured by the LHCb detector from $0.3\\,\\mathrm{nb}^{-1}$ of $pp$ collisions delivered by the LHC at $\\sqrt{s} = 0.9$\\,TeV and $1.8\\,\\mathrm{nb}^{-1}$ at $\\sqrt{s} = 7$\\,TeV. Both ratios are presented as a function of transverse momentum, $p_\\mathrm{T}$, and rapidity, $y$, in the ranges {$0.15 < p_\\mathrm{T} < 2.50\\,\\mathrm{GeV}/c$} and {$2.0measurements. The ratio $\\bar{\\Lambda} / \\Lambda$, measuring the transport of baryon number from the collision into the detector, is smaller in data than predicted in simulation, particularly at high rapidity. The ratio $\\bar{\\Lambda} / K^0_\\mathrm{S}$, measuring the baryon-to-meson suppression in strange quark hadronisation, is significantly larger than expected.

  9. Causal Indicator Models Have Nothing to Do with Measurement

    Science.gov (United States)

    Howell, Roy D.; Breivik, Einar

    2016-01-01

    In this article, Roy Howell, and Einar Breivik, congratulate Aguirre-Urreta, M. I., Rönkkö, M., & Marakas, G. M., for their work (2016) "Omission of Causal Indicators: Consequences and Implications for Measurement," Measurement: Interdisciplinary Research and Perspectives, 14(3), 75-97. doi:10.1080/15366367.2016.1205935. They call it…

  10. Measurement of the ratio h / e with a photomultiplier tube and a set of LEDs

    International Nuclear Information System (INIS)

    Loparco, F; Malagoli, M S; Rainò, S; Spinelli, P

    2017-01-01

    We propose a laboratory experience aimed at undergraduate physics students to understand the main features of the photoelectric effect and to perform a measurement of the ratio h / e , where h is Planck’s constant and e is the electron charge. The experience is based on the method developed by Millikan for his measurements of the photoelectric effect in the years from 1912 to 1915. The experimental setup consists of a photomultiplier tube (PMT) equipped with a voltage divider properly modified to set variable retarding potentials between the photocathode and the first dynode, and a set of LEDs emitting at different wavelengths. The photocathode is illuminated with the various LEDs and, for each wavelength of the incident light, the output anode current is measured as a function of the retarding potential applied between the cathode and the first dynode. From each measurement, a value of the stopping potential for the anode current is derived. Finally, the stopping potentials are plotted as a function of the frequency of the incident light, and a linear fit is performed. The slope and the intercept of the line allow one to respectively evaluate the ratio h / e and the ratio W / e , where W is the work function of the photocathode. (paper)

  11. Correction of mass spectrometric isotope ratio measurements for isobaric isotopologues of O2, CO, CO2, N2O and SO2.

    Science.gov (United States)

    Kaiser, Jan; Röckmann, Thomas

    2008-12-01

    Gas isotope ratio mass spectrometers usually measure ion current ratios of molecules, not atoms. Often several isotopologues contribute to an ion current at a particular mass-to-charge ratio (m/z). Therefore, corrections have to be applied to derive the desired isotope ratios. These corrections are usually formulated in terms of isotope ratios (R), but this does not reflect the practice of measuring the ion current ratios of the sample relative to those of a reference material. Correspondingly, the relative ion current ratio differences (expressed as delta values) are first converted into isotopologue ratios, then into isotope ratios and finally back into elemental delta values. Here, we present a reformulation of this data reduction procedure entirely in terms of delta values and the 'absolute' isotope ratios of the reference material. This also shows that not the absolute isotope ratios of the reference material themselves, but only product and ratio combinations of them, are required for the data reduction. These combinations can be and, for carbon and oxygen have been, measured by conventional isotope ratio mass spectrometers. The frequently implied use of absolute isotope ratios measured by specially calibrated instruments is actually unnecessary. Following related work on CO2, we here derive data reduction equations for the species O2, CO, N2O and SO2. We also suggest experiments to measure the required absolute ratio combinations for N2O, SO2 and O2. As a prelude, we summarise historic and recent measurements of absolute isotope ratios in international isotope reference materials. Copyright 2008 John Wiley & Sons, Ltd.

  12. Dimensions of osteoarthritis self-management.

    Science.gov (United States)

    Prior, Kirsty N; Bond, Malcolm J

    2004-06-01

    Our aims were to determine whether a taxonomy of self-management strategies for osteoarthritis could be identified, and whether the resultant dimensions of such a taxonomy demonstrate predictable relationships with health status indices. Participants (n = 117) from community-based self-help groups and a general rheumatology outpatient clinic completed a self-management inventory consisting of 11 items, answered for both the past 7 days and a day on which symptoms were worse than usual. Duration of symptoms, level of pain, perceived functional ability and self-rated health were recorded as indicators of health status. Three essentially identical factors were obtained for both past 7 days and worse day items. Resultant scales were labeled passive, complementary and active, respectively. Correlations with health status measures provided modest evidence for the construct validity of these self-management scales. Compared with a simple aggregate score based on the total number of strategies used, the scales provided a clearer understanding of the relationship between self-management and health. The study provided a useful extension to existing research, addressing a number of shortcomings identified by previous researchers. The identified self-management dimensions offered a greater insight into the self-management choices of patients. Suggestions for further improvements to the measurement of self-management are outlined.

  13. Study of the matrix specific mass discrimination effects during inductively coupled plasma mass spectrometry isotope ratio measurements

    International Nuclear Information System (INIS)

    Vassileva, E.; Quetel, Ch.R.

    2004-01-01

    Sample matrix related effects on mass discrimination during inductively coupled plasma mass spectrometry (ICP-MS) isotope ratio measurements have only been rarely reported. However, they can lead to errors larger than the uncertainty claimed on the ratio results when not properly taken into account or corrected for. These matrix specific affects were experienced during an Isotope Dilution Mass Spectrometry (IDMS) campaign we carried out for the certification of the Cd amount content in some food digest samples (7% acidity and salts content around 450μg g -1 ). Dilution was not possible for Cd only present at the low ng g -1 level. Up to 1% difference was observed on Cd isotope ratio results between measurements performed directly or after matrix separation. This was a significant difference considering that less than 1.5% relative combined uncertainty was eventually estimated for these IDMS measurements. Similar results could be obtained either way after the implementation of necessary corrections. The direct measurement approach associated to a correction for mass discrimination effects using the food digest sample itself (and the IUPAC table values as reference for the natural Cd isotopic composition) was preferred as it was the easiest. Consequently, the impact of matrix effects on mass discrimination during isotope ratio measurements with two types of ICP- MS (quadrupole and magnetic sector instruments) was studied for 4 elements (Li, Cu, Cd and Tl). Samples of varying salinity (up to 0.25%) and acidity (up to 7%) characteristics were prepared using isotopic certified reference materials of these elements. The long term and short-term stability, respectively reproducibility and repeatability, of the results, as well as the evolution of the difference to certified ratio values were monitored. As expected the 13 investigated isotopic ratios were all sensitive to variations in salt and acid concentrations. Our experiments also showed that simultaneous variation

  14. Self-Perceived Attractiveness, Romantic Desirability and Self-Esteem: A Mating Sociometer Perspective

    Directory of Open Access Journals (Sweden)

    Christopher Bale

    2013-01-01

    Full Text Available Sociometer theory proposes that self-esteem is an adaptation which evolved to monitor and regulate interpersonal relationships. It is therefore sensitive to self-assessments in domains relevant to relational desirability. Positive relationships between self-perceived physical attractiveness and self-esteem found in previous studies may reflect the functioning of a mating sociometer, designed to monitor individuals' desirability as romantic or sexual partners. We thus predicted that these relationships should be mediated by self-perceptions of romantic desirability, or more specifically, individuals' confidence in their abilities to successfully establish and maintain romantic relationships. Two hundred and eighty seven young adults (98 male completed an online measure of self-perceived attractiveness, together with measures of self-confidence in appearance and romantic relationships, body-esteem and global self-esteem. Linear regression analyses indicated that self-perceived attractiveness, self-confidence in appearance and body-esteem all significantly predicted self-esteem, and that in each case, the relationship was mediated by romantic self-confidence. Self-perceived attractiveness predicted self-esteem significantly more strongly in females than in males. We discuss these results in relation to sociometer and parental investment theories, and explore limitations and future directions.

  15. Self-perceived attractiveness, romantic desirability and self-esteem: a mating sociometer perspective.

    Science.gov (United States)

    Bale, Christopher; Archer, John

    2013-01-26

    Sociometer theory proposes that self-esteem is an adaptation which evolved to monitor and regulate interpersonal relationships. It is therefore sensitive to self-assessments in domains relevant to relational desirability. Positive relationships between self-perceived physical attractiveness and self-esteem found in previous studies may reflect the functioning of a mating sociometer, designed to monitor individuals' desirability as romantic or sexual partners. We thus predicted that these relationships should be mediated by self-perceptions of romantic desirability, or more specifically, individuals' confidence in their abilities to successfully establish and maintain romantic relationships. Two hundred and eighty seven young adults (98 male) completed an online measure of self-perceived attractiveness, together with measures of self-confidence in appearance and romantic relationships, body-esteem and global self-esteem. Linear regression analyses indicated that self-perceived attractiveness, self-confidence in appearance and body-esteem all significantly predicted self-esteem, and that in each case, the relationship was mediated by romantic self-confidence. Self-perceived attractiveness predicted self-esteem significantly more strongly in females than in males. We discuss these results in relation to sociometer and parental investment theories, and explore limitations and future directions.

  16. [Effects of Self-management Program applying Dongsasub Training on Self-efficacy, Self-esteem, Self-management Behavior and Blood Pressure in Older Adults with Hypertension].

    Science.gov (United States)

    Kim, Myoungsuk; Song, Misoon

    2015-08-01

    The purpose of this study was to develop a self-management program applying Dongsasub training based on self-efficacy theory, and to verify the program effectiveness on self-esteem as well as self-efficacy, self-management behaviors, and blood pressure. The study design was a non-equivalent, pre-post controlled quasi-experiment study. Thirty-eight patients aged 65 and older from a senior welfare center in Seoul participated in this study (20 patients in the experimental group and 18 patients in the control group). The self-management program applying Dongsasub training consisted of eight sessions. After development was complete the program was used with the experimental group. Outcome variables included self-efficacy, self-esteem, self-management behaviors measured by questionnaires, and blood pressure measured by electronic manometer. Self-efficacy (t=2.42, p=.021), self-esteem (t=2.57, p=.014) and self-management behaviors (t=2.21, p=.034) were significantly higher and systolic blood pressure (t=-2.14, p=.040) was significantly lower in the experimental group compared to the control group. However, diastolic blood pressure (t=-.85, p=.400) was not significantly different between the two groups. The results indicate that the self-management program applying Dongsasub training can be used as a nursing intervention in community settings for improving self-management behaviors for older adults with hypertension.

  17. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  18. Are oral health-related self-efficacy, knowledge and fatalism indicators for non-toothbrush ownership in a homeless population?

    Science.gov (United States)

    Jones, K; Brennan, D; Parker, E; Steffens, M; Jamieson, L

    2016-03-01

    To determine if the social cognitive theory (SCT)-constructs of oral health-related efficacy, knowledge and fatalism were indicators of non-toothbrush ownership in a metropolitan-based homeless population in Australia. Self-report data were collected from a convenience sample of 248 homeless participants located in Adelaide, Australia. Log binomial regression was used to estimate the strength of the association of the SCT constructs efficacy, knowledge and fatalism with the frequency of non-ownership of a toothbrush before and after adjusting for selected characteristics and associated factors. Of the study population (aged 17-78 years, 79% male) just over one-fifth (21%) did not own a toothbrush. In an unadjusted model, low self-efficacy (PR = 1.18) and low knowledge (1.27) were indicators for non-toothbrush ownership. These relationships were attenuated by 5.2% and 3.2% respectively after adjusting for social determinants, health factors, substance use and dental service utilisation-related factors, but remained statistically significant in the final model. Poor oral health-related self-efficacy and knowledge were both indicators for non-ownership of a toothbrush among a homeless population. This relationship held even after adjustment for relevant social and behavioural factors. Fatalism was not an indicator for non-toothbrush ownership in this population.

  19. The role of underestimating body size for self-esteem and self-efficacy among grade five children in Canada.

    Science.gov (United States)

    Maximova, Katerina; Khan, Mohammad K A; Austin, S Bryn; Kirk, Sara F L; Veugelers, Paul J

    2015-10-01

    Underestimating body size hinders healthy behavior modification needed to prevent obesity. However, initiatives to improve body size misperceptions may have detrimental consequences on self-esteem and self-efficacy. Using sex-specific multiple mixed-effect logistic regression models, we examined the association of underestimating versus accurate body size perceptions with self-esteem and self-efficacy in a provincially representative sample of 5075 grade five school children. Body size perceptions were defined as the standardized difference between the body mass index (BMI, from measured height and weight) and self-perceived body size (Stunkard body rating scale). Self-esteem and self-efficacy for physical activity and healthy eating were self-reported. Most of overweight boys and girls (91% and 83%); and most of obese boys and girls (93% and 90%) underestimated body size. Underestimating weight was associated with greater self-efficacy for physical activity and healthy eating among normal-weight children (odds ratio: 1.9 and 1.6 for boys, 1.5 and 1.4 for girls) and greater self-esteem among overweight and obese children (odds ratio: 2.0 and 6.2 for boys, 2.0 and 3.4 for girls). Results highlight the importance of developing optimal intervention strategies as part of targeted obesity prevention efforts that de-emphasize the focus on body weight, while improving body size perceptions. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Determination of /sup 240/Pu//sup 239/Pu ratio in the environmental samples based on the measurement of Lx/. cap alpha. -ray activity ratio

    Energy Technology Data Exchange (ETDEWEB)

    Komura, K.; Sakanoue, M.; Yamamoto, M.

    1984-06-01

    The determination of the /sup 240/Pu//sup 239/Pu isotopic ratio in environmental samples has been attempted by the measurement of the Lx/..cap alpha..-ray activity ratio using a Ge-LEPS (low-energy photon spectrometer) and a surface-barrier Si detector. By this method, interesting data were obtained for various samples collected from Thule, Greenland, Bikini Atoll and Nagasaki, as well as for some soils collected from near and off-site locations of atomic power stations.

  1. On monitoring anthropogenic airborne uranium concentrations and 235U/238U isotopic ratio by Lichen - bio-indicator technique

    International Nuclear Information System (INIS)

    Golubev, A.V.; Golubeva, V.N.; Krylov, N.G.; Kuznetsova, V.F.; Mavrin, S.V.; Aleinikov, A.Yu.; Hoppes, W.G.; Surano, K.A.

    2005-01-01

    Lichens are widely used to assess the atmospheric pollution by heavy metals and radionuclides. However, few studies are available in publications on using lichens to qualitatively assess the atmospheric pollution levels. The paper presents research results applying epiphytic lichens as bio-monitors of quantitative atmospheric contamination with uranium. The observations were conducted during 2.5 years in the natural environment. Two experimental sites were used: one in the vicinity of a uranium contamination source, the other one - at a sufficient distance away to represent the background conditions. Air and lichens were sampled at both sites monthly. Epiphytic lichens Hypogimnia physodes were used as bio-indicators. Lichen samples were taken from various trees at about 1.5m from the ground. Air was sampled with filters at sampling stations. The uranium content in lichen and air samples as well as isotopic mass ratios 235 U/ 238 U were measured by mass-spectrometer technique after uranium pre-extraction. Measured content of uranium were 1.45mgkg -1 in lichen at 2.09E-04μgm -3 in air and 0.106mgkg -1 in lichen at 1.13E-05μgm -3 in air. The relationship of the uranium content in atmosphere and that in lichens was determined, C AIR =exp(1.1xC LICHEN -12). The possibility of separate identification of natural and man-made uranium in lichens was demonstrated in principle

  2. Design and Analyses of High Aspect Ratio Nozzles for Distributed Propulsion Acoustic Measurements

    Science.gov (United States)

    Dippold, Vance F., III

    2016-01-01

    A series of three convergent round-to-rectangular high-aspect ratio nozzles were designed for acoustics measurements. The nozzles have exit area aspect ratios of 8:1, 12:1, and 16:1. With septa inserts, these nozzles will mimic an array of distributed propulsion system nozzles, as found on hybrid wing-body aircraft concepts. Analyses were performed for the three nozzle designs and showed that the flow through the nozzles was free of separated flow and shocks. The exit flow was mostly uniform with the exception of a pair of vortices at each span-wise end of the nozzle.

  3. Non-intrusive measurement of emission indices. A new approach to the evaluation of infrared spectra emitted by aircraft engine exhaust gases

    Energy Technology Data Exchange (ETDEWEB)

    Lindermeir, E.; Haschberger, P.; Tank, V. [Deutsche Forschungsanstalt fuer Luft- und Raumfahrt e.V. (DLR), Wessling (Germany). Inst. fuer Optoelektronik

    1997-12-31

    A non-intrusive method is used to determine the emission indices of a research aircraft`s engine in-flight. The principle is based on the Fourier Transform Infrared Spectrometer MIROR which was specifically designed and built for operation aboard aircrafts. This device measures the spectrum of the infrared radiation emitted by the hot exhaust gas under cruise conditions. From these spectra mixing ratios and emission indices can be derived. An extension to previously applied evaluation schemes is proposed: Whereas formerly the plume was assumed a homogeneous layer of gas, temperature and concentration profiles are now introduced to the evaluation procedure. (author) 5 refs.

  4. X-Ray Investigation and Strength Measurement of Steel Fibre Reinforced Self-Compacting Concrete Beams

    Directory of Open Access Journals (Sweden)

    Ponikiewski Tomasz

    2016-12-01

    Full Text Available The paper presents a study on self-compacting concrete with two types of steel fibres. Under consideration was the effect the method of forming of beam elements has on the distribution of steel fibres. Formed we beams of dimensions 120×15×15 cm3 and 180×15×15 cm3. The self-compacting mixture contained steel fibres of varying lengths (35 and 50 mm and varying levels of their volume ratio in the mix (0.5% - 1.0% - 1.5%.

  5. Who Take Naps? Self-Reported and Objectively Measured Napping in Very Old Women.

    Science.gov (United States)

    Leng, Yue; Stone, Katie; Ancoli-Israel, Sonia; Covinsky, Kenneth; Yaffe, Kristine

    2018-03-02

    Despite the widespread belief that napping is common among older adults, little is known about the correlates of napping. We examined the prevalence and correlates of self-reported and objectively measured napping among very old women. We studied 2,675 community-dwelling women (mean age 84.5 ± 3.7 years; range 79-96). Self-reported napping was defined as a report of regular napping for ≥1 hour per day. Individual objective naps were defined as ≥5 consecutive minutes of inactivity as measured by actigraphy and women were characterized as "objective nappers" if they had at least 60 minutes of naps per day. Seven percent of the women only had self-reported napping, 29% only had objective napping, and 14% met the criteria for both. Multinomial logistic regression showed that the independent correlates of "both subjective and objective napping" were age (per 5 year odds ratio [OR] = 1.59; 95% CI: 1.31-1.93), depressive symptoms (per SD of score, OR = 1.53; 1.32-1.77), obesity (OR =1.93; 1.42-2.61), current smoking (OR = 3.37; 1.56-7.30), heavier alcohol drinking (OR = 0.49; 0.34-0.71), history of stroke (OR = 1.56; 1.08-2.26), diabetes (OR = 2.40; 1.61-3.57), dementia (OR = 3.31; 1.27-8.62), and Parkinson's disease (OR = 7.43; 1.87-29.50). Besides, having objective napping alone was associated with age and diabetes, whereas subjective napping was associated with stroke and myocardial infarction. These associations were independent of nighttime sleep duration and fragmentation. Daytime napping is very common in women living in their ninth decade and both subjective and objective napping were significantly related to age and comorbidities. Future studies are needed to better understand napping and its health implications. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Prematurity and parental self-efficacy: the Preterm Parenting & Self-Efficacy Checklist.

    Science.gov (United States)

    Pennell, Claire; Whittingham, Koa; Boyd, Roslyn; Sanders, Matthew; Colditz, Paul

    2012-12-01

    There is a lack of research investigating parental self-efficacy in parents of infants born preterm as well as a paucity of parental self-efficacy measures that are domain-specific and theoretically grounded. This study aimed to compare parental self-efficacy in parents of infants born term, preterm and very preterm as well as to test whether parental self-efficacy mediates the relationship between psychological symptoms and parental competence. In order to achieve this, a new measure of parental self-efficacy and parental competence relevant for the preterm population and consistent with Bandura's (1977, 1986, 1989) conceptualisation of self-efficacy was developed. Participants included 155 parents, 83 of whom were parents of very preterm (GAparents of preterm (GAparents of term born infants. Parents completed the Preterm Parenting & Self-Efficacy Checklist (the new measure), Family Demographic Questionnaire, Depression Anxiety Stress Scale and Self-Efficacy Questionnaire. This initial study indicates that the Preterm Parenting & Self-Efficacy Checklist has adequate content validity, construct validity, internal consistency and split half reliability. Contrary to expectations, parents of very preterm infants did not report significantly lower overall levels of parental self-efficacy or significantly higher levels of psychological symptoms compared to parents of preterm and term infants. Parental self-efficacy about parenting tasks mediated the relationship between psychological symptoms and self perceived parental competence as predicted. Clinical implications of the results and suggestions for future research are discussed. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  7. Self-esteem and delusion proneness.

    Science.gov (United States)

    Warman, Debbie M; Lysaker, Paul H; Luedtke, Brandi; Martin, Joel M

    2010-06-01

    The present study was an examination of global self-esteem and various types of unusual beliefs in a nonclinical population. Individuals with no history of psychotic disorder (N = 121) completed a measure of delusion-proneness and also a measure of self-esteem. Results indicated high delusion prone individuals had lower self-esteem than low delusion prone individuals (p = 0.044). In addition, higher levels of paranoid ideation and suspiciousness were associated with lower self-esteem (p low self-esteem and higher levels of beliefs related to thought disturbances, catastrophic ideation/thought broadcasting, and ideation of reference/influence. The significance of these findings as they relate to theories of delusion formation is discussed.

  8. Measuring and Supporting Pre-Service Teachers' Self-Efficacy towards Computers, Teaching, and Technology Integration

    Science.gov (United States)

    Killi, Carita; Kauppinen, Merja; Coiro, Julie; Utriainen, Jukka

    2016-01-01

    This paper reports on two studies designed to examine pre-service teachers' self-efficacy beliefs. Study I investigated the measurement properties of a self-efficacy beliefs questionnaire comprising scales for computer self-efficacy, teacher self-efficacy, and self-efficacy towards technology integration. In Study I, 200 pre-service teachers…

  9. Implicit versus explicit measures of self-concept of self-control and their differential predictive power for spontaneous trait-relevant behaviors

    NARCIS (Netherlands)

    Huntjens, Rafaële J C; Rijkeboer, Marleen M; Krakau, Andrej; de Jong, Peter J

    BACKGROUND AND OBJECTIVES: Low trait self-control constitutes a core criterion in various psychiatric disorders. Personality traits such as low self-control are mostly indexed by self-report measures. However, several theorists emphasized the importance of differentiating between explicit and

  10. Measurement of the nuclear multiplicity ratio for Ks0 hadronization at CLAS

    Science.gov (United States)

    Daniel, A.; Hicks, K.; Brooks, W. K.; Hakobyan, H.; Adhikari, K. P.; Adikaram, D.; Aghasyan, M.; Amarian, M.; Anghinolfi, M.; Avakian, H.; Baghdasaryan, H.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Bennett, R. P.; Biselli, A. S.; Bookwalter, C.; Briscoe, W. J.; Burkert, V. D.; Carman, D. S.; Casey, L.; Celentano, A.; Chandavar, S.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Dey, B.; Dickson, R.; Djalali, C.; Dodge, G. E.; Doughty, D.; Egiyan, H.; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guo, L.; Hanretty, C.; Heddle, D.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jawalkar, S. S.; Jo, H. S.; Joo, K.; Kalantarians, N.; Keller, D.; Khandaker, M.; Khetarpal, P.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, V.; Kuleshov, S. V.; Kuznetsov, V.; Lu, H. Y.; MacGregor, I. J. D.; Mao, Y.; Markov, N.; Mayer, M.; McAndrew, J.; McKinnon, B.; Meyer, C. A.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Moutarde, H.; Munevar, E.; Nadel-Turonski, P.; Ni, A.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Paolone, M.; Pappalardo, L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Anefalos Pereira, S.; Phelps, E.; Pisano, S.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Raue, B. A.; Ricco, G.; Rimal, D.; Ripani, M.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Salgado, C.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Vineyard, M. F.; Voskanyan, H.; Voutier, E.; Watts, D. P.; Weinstein, L. B.; Weygand, D. P.; Wood, M. H.; Zana, L.; Zachariou, N.; Zhao, B.; Zhao, Z. W.

    2011-11-01

    The influence of cold nuclear matter on lepto-production of hadrons in semi-inclusive deep inelastic scattering is measured using the CLAS detector in Hall B at Jefferson Lab and a 5.014 GeV electron beam. We report the Ks0 multiplicity ratios for targets of C, Fe, and Pb relative to deuterium as a function of the fractional virtual photon energy z transferred to the Ks0 and the transverse momentum squared pT2 of the Ks0. We find that the multiplicity ratios for Ks0 are reduced in the nuclear medium at high z and low pT2, with a trend for the Ks0 transverse momentum to be broadened in the nucleus for large pT2.

  11. Measuring Cognitive Load: A Comparison of Self-Report and Physiological Methods

    Science.gov (United States)

    Joseph, Stacey

    2013-01-01

    This study explored three methods to measure cognitive load in a learning environment using four logic puzzles that systematically varied in level of intrinsic cognitive load. Participants' perceived intrinsic load was simultaneously measured with a self-report measure-a traditional subjective measure-and two objective, physiological measures…

  12. Sex and Self-Control Theory: The Measures and Causal Model May Be Different

    Science.gov (United States)

    Higgins, George E.; Tewksbury, Richard

    2006-01-01

    This study examines the distribution differences across sexes in key measures of self-control theory and differences in a causal model. Using cross-sectional data from juveniles ("n" = 1,500), the study shows mean-level differences in many of the self-control, risky behavior, and delinquency measures. Structural equation modeling…

  13. Mapping the nomological network of employee self-determined safety motivation: A preliminary measure in China.

    Science.gov (United States)

    Jiang, Li; Tetrick, Lois E

    2016-09-01

    The present study introduced a preliminary measure of employee safety motivation based on the definition of self-determination theory from Fleming (2012) research and validated the structure of self-determined safety motivation (SDSM) by surveying 375 employees in a Chinese high-risk organization. First, confirmatory factor analysis (CFA) was used to examine the factor structure of SDSM, and indices of five-factor model CFA met the requirements. Second, a nomological network was examined to provide evidence of the construct validity of SDSM. Beyond construct validity, the analysis also produced some interesting results concerning the relationship between leadership antecedents and safety motivation, and between safety motivation and safety behavior. Autonomous motivation was positively related to transformational leadership, negatively related to abusive supervision, and positively related to safety behavior. Controlled motivation with the exception of introjected regulation was negatively related to transformational leadership, positively related to abusive supervision, and negatively related to safety behavior. The unique role of introjected regulation and future research based on self-determination theory were discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Do Self Concept Tests Test Self Concept? An Evaluation of the Validity of Items on the Piers Harris and Coopersmith Measures.

    Science.gov (United States)

    Lynch, Mervin D.; Chaves, John

    Items from Peirs-Harris and Coopersmith self-concept tests were evaluated against independent measures on three self-constructs, idealized, empathic, and worth. Construct measurements were obtained with the semantic differential and D statistic. Ratings were obtained from 381 children, grades 4-6. For each test, item ratings and construct measures…

  15. Properties of laser-produced GaAs plasmas measured from highly resolved X-ray line shapes and ratios

    Science.gov (United States)

    Seely, J. F.; Fein, J.; Manuel, M.; Keiter, P.; Drake, P.; Kuranz, C.; Belancourt, Patrick; Ralchenko, Yu.; Hudson, L.; Feldman, U.

    2018-03-01

    The properties of hot, dense plasmas generated by the irradiation of GaAs targets by the Titan laser at Lawrence Livermore National Laboratory were determined by the analysis of high resolution K shell spectra in the 9 keV to 11 keV range. The laser parameters, such as relatively long pulse duration and large focal spot, were chosen to produce a steady-state plasma with minimal edge gradients, and the time-integrated spectra were compared to non-LTE steady state spectrum simulations using the FLYCHK and NOMAD codes. The bulk plasma streaming velocity was measured from the energy shifts of the Ga He-like transitions and Li-like dielectronic satellites. The electron density and the electron energy distribution, both the thermal and the hot non-thermal components, were determined from the spectral line ratios. After accounting for the spectral line broadening contributions, the plasma turbulent motion was measured from the residual line widths. The ionization balance was determined from the ratios of the He-like through F-like spectral features. The detailed comparison of the experimental Ga spectrum and the spectrum simulated by the FLYCHK code indicates two significant discrepancies, the transition energy of a Li-like dielectronic satellite (designated t) and the calculated intensity of a He-like line (x), that should lead to improvements in the kinetics codes used to simulate the X-ray spectra from highly-charged ions.

  16. Biphasic DC measurement approach for enhanced measurement stability and multi-channel sampling of self-sensing multi-functional structural materials doped with carbon-based additives

    Science.gov (United States)

    Downey, Austin; D'Alessandro, Antonella; Ubertini, Filippo; Laflamme, Simon; Geiger, Randall

    2017-06-01

    Investigation of multi-functional carbon-based self-sensing structural materials for structural health monitoring applications is a topic of growing interest. These materials are self-sensing in the sense that they can provide measurable electrical outputs corresponding to physical changes such as strain or induced damage. Nevertheless, the development of an appropriate measurement technique for such materials is yet to be achieved, as many results in the literature suggest that these materials exhibit a drift in their output when measured with direct current (DC) methods. In most of the cases, the electrical output is a resistance and the reported drift is an increase in resistance from the time the measurement starts due to material polarization. Alternating current methods seem more appropriate at eliminating the time drift. However, published results show they are not immune to drift. Moreover, the use of multiple impedance measurement devices (LCR meters) does not allow for the simultaneous multi-channel sampling of multi-sectioned self-sensing materials due to signal crosstalk. The capability to simultaneously monitor multiple sections of self-sensing structural materials is needed to deploy these multi-functional materials for structural health monitoring. Here, a biphasic DC measurement approach with a periodic measure/discharge cycle in the form of a square wave sensing current is used to provide consistent, stable resistance measurements for self-sensing structural materials. DC measurements are made during the measurement region of the square wave while material depolarization is obtained during the discharge region of the periodic signal. The proposed technique is experimentally shown to remove the signal drift in a carbon-based self-sensing cementitious material while providing simultaneous multi-channel measurements of a multi-sectioned self-sensing material. The application of the proposed electrical measurement technique appears promising for real

  17. Self-stigma in depressive patients: Association of cognitive schemata, depression, and self-esteem.

    Science.gov (United States)

    Shimotsu, Sakie; Horikawa, Naoshi

    2016-12-01

    Many empirical studies have indicated that various psychosocial and psychiatric variables are correlated with levels of self-stigma. Treatment methods for reducing self-stigma have been investigated in recent years, especially those examining the relationship between negative cognitive schemata and self-stigma. This study examined the relationship of self-stigma with cognitive schemata, depression, and self-esteem in depressive patients. Furthermore, structural equation modeling (SEM) was conducted to evaluate three hypothetical models. Study participants were 110 patients with depression (54 men, 56 women; mean age=45.65years, SD=12.68; 83 diagnosed with mood disorders; 22 with neurotic, stress-related, or somatoform disorders; and 5 with other disorders) attending a psychiatric service. Outcomes were measured using the Japanese versions of the Devaluation-Discrimination Scale, Dysfunctional Attitude Scale, Center for Epidemiologic Studies Depression Scale, and Rosenberg's Self Esteem Scale. The analysis indicated a better fit of the model that assumed self-stigma as mediator, suggesting that cognitive schemata influence self-stigma, while self-stigma affects depression and self-esteem. The tested models using SEM indicated that (1) self-stigma has the potential to mediate the relationship between cognitive schemata and depression, and (2) depression and self-stigma have a similar influence on self-esteem. Although low self-esteem is considered one of the symptoms of depression, when we aim to recover self-esteem, we do not only observe improvement in depressive symptoms; thus, approaches that focus on the reduction of self-stigma are probably valid. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Improved environmental and forensics measurements using multiple ion counters in isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Goldberg, S.A.; Richter, S.; Schwieters, H.

    2002-01-01

    Full text: A new detector system designed for isotope ratio mass spectrometers provides improved precision on measurements of samples with very low amounts ( -11 grams) of analyte. An array of continuous dynode electron multipliers has been installed on a new ThermoFinnigan MAT Triton thermal ionization mass spectrometer acquired by the New Brunswick Laboratory. These ion counters are modifications of miniaturized, commercially-available continuous dynode electron multipliers. They can be readily installed to replace individual Faraday cups in a multi-detector mass spectrometer or bundled together and located along the detector plane with a set of Faraday cups. On the New Brunswick Laboratory mass spectrometer, nine Faraday cups, one conventional discrete dynode electron multiplier, and seven miniaturized ion counters were installed. Six of the small ion counters were bundled together and positioned on the high mass side of the Low 4 Faraday cup. One additional ion counter was positioned on the low mass side of the Low 4 Faraday cup. This arrangement allows for the simultaneous measurement of all uranium (including 233 U) or plutonium (including 244 Pu) isotopes, and allows for the measurement of larger 238 U intensities on the Faraday cup if needed. Unit mass spacing of U, Pu, or other actinides is readily achieved by the use of a mass dispersion zoom lens. The advantage of multiple ion counting is the simultaneous collection of isotopes. It overcomes many of the problems such as transient signal variation in sample emission and ionization. For a given sample, multiple ion counting generates a greater number of counts for each isotope relative to single detector ion counting and provides improved counting statistics by a factor of two or more. Initial tests indicate that the multiple ion counters exhibit high counting efficiency, a dark noise of less than 10 counts per minute and typically less than 1 count per minute, and show linear response characteristics over

  19. Tracer-based laser-induced fluorescence measurement technique for quantitative fuel/air-ratio measurements in a hydrogen internal combustion engine.

    Science.gov (United States)

    Blotevogel, Thomas; Hartmann, Matthias; Rottengruber, Hermann; Leipertz, Alfred

    2008-12-10

    A measurement technique for the quantitative investigation of mixture formation processes in hydrogen internal combustion engines (ICEs) has been developed using tracer-based laser-induced fluorescence (TLIF). This technique can be employed to fired and motored engine operation. The quantitative TLIF fuel/air-ratio results have been verified by means of linear Raman scattering measurements. Exemplary results of the simultaneous investigation of mixture formation and combustion obtained at an optical accessible hydrogen ICE are shown.

  20. Pitfalls with the use of enhancement ratios or normalized excess mixing ratios measured in plumes to characterize pollution sources and aging

    Directory of Open Access Journals (Sweden)

    R. J. Yokelson

    2013-08-01

    Full Text Available Normalized excess mixing ratios (NEMRs, also known as enhancement ratios, are a common way to characterize plumes of pollution in atmospheric research. As single-source pollutant plumes disperse in the atmosphere, they are diluted by mixing with the adjacent background air. Changes in the composition of this background air can cause large changes to the NEMR that is subsequently measured by remote-sensing, airborne, or ground-based instruments. This scenario is common when boundary layer plumes enter the free troposphere and could also impact long-range transport or plumes near the top of the troposphere. We provide a context for these issues and an example showing that neglect of this effect could lead to serious errors in data interpretation.