WorldWideScience

Sample records for self-diagnostics digitally controlled

  1. Digitized self-oscillating loop for piezoelectric transformer-based power converters

    DEFF Research Database (Denmark)

    Ekhtiari, Marzieh; Andersen, Thomas; Zhang, Zhe

    2016-01-01

    A new method is implemented in designing of self-oscillating loop for driving piezoelectric transformers. The implemented method is based on combining both analog and digital control systems. Digitized delay, or digitized phase shift through the self-oscillating loop results in a very precise...... frequency control and ensures an optimum operation of the piezoelectric transformer in terms of voltage gain and efficiency. In this work, additional time delay is implemented digitally for the first time through 16 bit digital-to-analog converter to the self-oscillating loop. Delay control setpoints...... updates at a rate of 417 kHz. This allows the control loop to dynamically follow frequency changes of the transformer in each resonant cycle. The operation principle behind self-oscillating is discussed in this paper. Moreover, experimental results are reported....

  2. Managing digitally formatted diagnostic image data

    International Nuclear Information System (INIS)

    Templeton, A.W.; Dwyer, S.J.

    1985-01-01

    Diagnostic radiologists are very comfortable using analog radiographic film and interpreting its recorded images. To improve patient care, the radiologist has sought the finest quality radiographic film for use with the best radiographic imaging systems. The proper choice and use of x-ray tubes, generators, film-screen combinations, and contrast media has occupied the professional attention of the radiologist since the inception of radiology. Image quality can be significantly improved with digitally formatted diagnostic imaging systems by providing dynamic ranges in excess of those possible with analog x-ray films. In a CT scanner, the digital acquisition and reconstruction system can obtain a dynamic range (contrast resolution) of 10,000 to 1. Digital subtraction angiography systems achieve 10-bit dynamic ranges for each of the acquired television frames. Increases in the dynamic ranges of the various imaging modalities have been coupled with improved spatial resolution. A digitally formatted image is a two-dimensional, numerical array of discrete image elements. Each picture element is called a pixel. Each pixel has a discrete size. Figure 15.1 illustrates a digitally formatted image depicting the spatial resolution, array size, and quantization or numerical range of the pixel values. Currently, 512 x 512 image arrays are standard. Development of 1024 x 1024 digital arrays are underway. Significant improvements have also been achieved in the rates at which digital diagnostic imaging data can be acquired, manipulated, and archived

  3. Establishing diagnostic reference levels in digital radiology

    International Nuclear Information System (INIS)

    Bana, Remy Wilson

    2016-04-01

    Medical application of radiation has gained wider study since diagnostic radiology plays a very important role in modern medicine. The need of the service seems to increase since the invention of digital radiology as a new technology that promises greater accuracy while minimizing patient dose. However, it is not exempted in the harmonization of doses delivered to the patient undergoing same radiologic examination in different institutions either regional or nationwide. The objective of this project was to review the establishment of Diagnostic Reference Levels (DRLs) in digital radiology at National level with the aim to reduce patient dose while maintaining appropriate image quality. A general discussion on digital radiology has been presented focusing on the optimization of patient dose as well as dosimetric quantities used for the establishment of DRLs. Recommendations have been provided for Rwanda to initiate steps to establish National Diagnostic Reference Levels for common procedures in digital radiology. (au)

  4. Development of reconfigurable analog and digital circuits for plasma diagnostics measurement systems

    International Nuclear Information System (INIS)

    Srivastava, Amit Kumar; Sharma, Atish; Raval, Tushar

    2009-01-01

    In long pulse discharge tokamak, a large number of diagnostic channels are being used to understand the complex behavior of plasma. Different diagnostics demand different types of analog and digital processing for plasma parameters measurement. This leads to variable requirements of signal processing for diagnostic measurement. For such types of requirements, we have developed hardware with reconfigurable electronic devices, which provide flexible solution for rapid development of measurement system. Here the analog processing is achieved by Field Programmable Analog Array (FPAA) integrated circuit while reconfigurable digital devices (CPLD/FPGA) achieve digital processing. FPAA's provide an ideal integrated platform for implementing low to medium complexity analog signal processing. With dynamic reconfigurability, the functionality of the FPAA can be reconfigured in-system by the designer or on the fly by a microprocessor. This feature is quite useful to manipulate the tuning or the construction of any part of the analog circuit without interrupting operation of the FPAA, thus maintaining system integrity. The hardware operation control logic circuits are configured in the reconfigurable digital devices (CPLD/FPGA) to control proper hardware functioning. These reconfigurable devices provide the design flexibility and save the component space on the board. It also provides the flexibility for various setting through software. The circuit controlling commands are either issued by computer/processor or generated by circuit itself. (author)

  5. Clinical applications of SONIALVISION 100 digital diagnostic table system

    International Nuclear Information System (INIS)

    Shiomi, Takeshi; Shimizu, Tatsuya; Iinuma, Masao; Takemoto, Hajime; Tanaka, Shuji

    2003-01-01

    This report refers to the clinical applications of our newly developed SONIALVISION 100 fully digitalized X-ray diagnostic table system. The main design concept of the SONIALVISION 100 system is the improvement of workflow in various clinical fields. The development of digital imaging technologies has come to allow fully digitalized X-ray diagnostic table systems to be widely utilized in various clinical applications, including interventional radiology (IVR) and examinations using contrast medium. This report mainly refers to the clinical applications of the Shimadzu SONIALVISION 100 digitalized X-ray diagnostic table system, also presenting some typical image data demonstrating the high efficiency, made available through the use of this new system, in high-speed spot imaging and digital tomography. (author)

  6. Diagnostic time in digital pathology: A comparative study on 400 cases

    Directory of Open Access Journals (Sweden)

    Aleksandar Vodovnik

    2016-01-01

    Full Text Available Background: Numerous validation studies in digital pathology confirmed its value as a diagnostic tool. However, a longer time to diagnosis than traditional microscopy has been seen as a significant barrier to the routine use of digital pathology. As a part of our validation study, we compared a digital and microscopic diagnostic time in the routine diagnostic setting. Materials and Methods: One senior staff pathologist reported 400 consecutive cases in histology, nongynecological, and fine needle aspiration cytology (20 sessions, 20 cases/session, over 4 weeks. Complex, difficult, and rare cases were excluded from the study to reduce the bias. A primary diagnosis was digital, followed by traditional microscopy, 6 months later, with only request forms available for both. Microscopic slides were scanned at ×20, digital images accessed through the fully integrated laboratory information management system (LIMS and viewed in the image viewer on double 23” displays. A median broadband speed was 299 Mbps. A diagnostic time was measured from the point slides were made available to the point diagnosis was made or additional investigations were deemed necessary, recorded independently in minutes/session and compared. Results: A digital diagnostic time was 1841 and microscopic 1956 min; digital being shorter than microscopic in 13 sessions. Four sessions with shorter microscopic diagnostic time included more cases requiring extensive use of magnifications over ×20. Diagnostic time was similar in three sessions. Conclusions: A diagnostic time in digital pathology can be shorter than traditional microscopy in the routine diagnostic setting, with adequate and stable network speeds, fully integrated LIMS and double displays as default parameters. This also related to better ergonomics, larger viewing field, and absence of physical slide handling, with effects on both diagnostic and nondiagnostic time. Differences with previous studies included a design

  7. Diagnostic ability of the periapical radiographs and digital image in the detection of the artificial proximal caries

    International Nuclear Information System (INIS)

    Heo, Min Suk; You, Dong Soo

    1994-01-01

    Recently, the digital image was introduced into radiological image. The digital image has the power of contrast enhancement, histogram control, and other digitally enhancement. At the point of the resolution, periapical radiograph is superior to the digital image, but enhanced digital procedure improves the diagnostic ability of the digital image. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries in conventional radiographs, digital radiographs and enhanced digital radiographs (histogram specification). ROC (Receiver Operating Characteristic) analysis and paired t-test were used for the evaluation of detectability, and following results were acquired: 1. The mean ROC area of conventional radiographs was 0.9274. 2. The mean ROC area of unenhanced digital image was 0.9168. 3. The mean ROC area of enhanced digital image was 0.9339. 4. The diagnostic ability of three imaging methods was not significant difference (p>0.05). So, the digital images had similar diagnostic ability of artificial proximal caries to conventional radiographs. If properly enhanced digital image, it may be superior to conventional radiographs.

  8. Official criteria for diagnostics of diabetes mellitus, normoglycemia and glycemic self-control

    Directory of Open Access Journals (Sweden)

    O.V. Kaminskiy

    2017-04-01

    Full Text Available The paper considers the questions of diagnostics of diabetes mellitus (DM and early violations of carbohydrate metabolism. Venous plasma was underlined to be the only commonly accepted standard for blood glucose determination for prediabetes and diabetes mellitus diagnosis. In the third world countries (including Ukraine peripheral (capillary plasma of blood can be used for self-control and diagnostics of prediabetes and DM as their fasting values correspond to those of venous plasma and do not require revaluation. While using portable glucometers for carbohydrate violations diagnostics postprandial glucose value and after meal should be estimated in conversion. Normoglycemia is glucose concentration in venous plasma from 3.9 mmol/l (ADA criteria to 6.0 mmol/l (WHO criteria.

  9. Digital Self-Harm Among Adolescents.

    Science.gov (United States)

    Patchin, Justin W; Hinduja, Sameer

    2017-12-01

    Despite increased media and scholarly attention to digital forms of aggression directed toward adolescents by their peers (e.g., cyberbullying), very little research has explored digital aggression directed toward oneself. "Digital self-harm" is the anonymous online posting, sending, or otherwise sharing of hurtful content about oneself. The current study examined the extent of digital self-harm among adolescents. Survey data were obtained in 2016 from a nationally representative sample of 5,593 American middle and high school students (12-17 years old). Logistic regression analysis was used to identify correlates of participation in digital self-harm. Qualitative responses were also reviewed to better understand motivations for digital self-harm. About 6% of students have anonymously posted something online about themselves that was mean. Males were significantly more likely to report participation (7.1% compared to 5.3%). Several statistically significant correlates of involvement in digital self-harm were identified, including sexual orientation, experience with school bullying and cyberbullying, drug use, participation in various forms of adolescent deviance, and depressive symptoms. Digital self-harm is a new problem that demands additional scholarly attention. A deeper inquiry as to the motivations behind this behavior, and how it correlates to offline self-harm and suicidal ideation, can help direct mental health professionals toward informed prevention approaches. Copyright © 2017 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  10. Advantages of digital imaging for radiological diagnostic

    International Nuclear Information System (INIS)

    Trapero, M. A.; Gonzalez, S.; Albillos, J. C.; Martel, J.; Rebollo, M.

    2006-01-01

    The advantages and limitations of radiological digital images in comparison with analogic ones are analyzed. We discuss three main topics: acquisition, post-procedure manipulation, and visualization, archive and communication. Digital acquisition with computed radiology systems present a global sensitivity very close to conventional film for diagnostic purposes. However, flat panel digital systems seems to achieve some advantages in particular clinical situations. A critical issue is the radiation dose-reduction that can be accomplished without reducing image quality nor diagnostic exactitude. The post-procedure manipulation allows, particularly in multiplanar modalities like CT or MR, to extract all implicit diagnostic information in the images: Main procedures are multiplanar and three-dimensional reformations, dynamic acquisitions, functional studies and image fusion. The use of PACS for visualization, archive and communication of images, improves the effectiveness and the efficiency of the workflow, allows a more comfortable diagnosis for the radiologist and gives way to improvements in the communication of images, allowing tele consulting and the tele radiology. (Author) 6 refs

  11. Regulatory issues of digital instrumentation and control system in Lungmen project

    International Nuclear Information System (INIS)

    Chuang, C.F.; Chou, H.P.

    2004-01-01

    The Lungmen Nuclear Power Station (LNPS) is currently under construction in Taiwan, which consists of 2 advanced boiling water reactor (ABWR) units. The instrumentation and control (IC) systems of the LNPS are based on the state-of-the-art modernized fully integrated digital design. These IC systems possess many advantages and distinguished features comparing to traditional analog IC systems, they enjoy set-point stability, self-diagnostic and automatic testing ability, fault tolerance and avoidance, low power requirements, data handling and storage capability, as well as enhanced human-machine interfaces. This paper presents regulatory overviews, regulatory requirements, current major regulatory issues, as well as the areas of regulatory concerns and the lessons learned on the digital IC systems in the Lungmen Project

  12. How does a change in the control room design affect diagnostic strategies in nuclear power plants?

    International Nuclear Information System (INIS)

    Kim, Dong Young; Kim, Jonghyun

    2014-01-01

    Recently, main control rooms have been considerably changed by modern computer techniques. Some of the features that distinguish digital control rooms from conventional, analog rooms in nuclear power plants include advanced alarm systems, graphic information display systems, computerized procedure systems, and soft control. These features can bring changes in operator tasks, changing the characteristics of tasks or creating new tasks for operators. It is especially expected that these features may bring out changes in the operator's diagnostic tasks and strategies in a digital control room as compared with an analog control room. This study investigates the differences in the operator's diagnostic tasks and strategies in analog and digital control rooms. This study also attempts to evaluate how new systems in a digital control room affect diagnostic strategies. Three different approaches, which are complementary, are used to identify diagnostic strategies in the digital control room and in the analog control room: (1) observation in the simulator, (2) interview with operators, and (3) a literature review. The results show that the digital control room introduces new diagnosis strategies compared with the analog control room while also changing the characteristics of the strategies, mostly by gaining more support from the computerized system. (author)

  13. Systems and methods for self-synchronized digital sampling

    Science.gov (United States)

    Samson, Jr., John R. (Inventor)

    2008-01-01

    Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

  14. Advanced digital computers, controls, and automation technologies for power plants: Proceedings

    International Nuclear Information System (INIS)

    Bhatt, S.C.

    1992-08-01

    This document is a compilation of the papers that were presented at an EPRI workshop on Advances in Computers, Controls, and Automation Technologies for Power Plants. The workshop, sponsored by EPRI's Nuclear Power Division, took place February 1992. It was attended by 157 representatives from electric utilities, equipment manufacturers, engineering consulting organizations, universities, national laboratories, government agencies and international utilities. More than 40% of the attendees were from utilities representing the majority group. There were 30% attendees from equipment manufacturers and the engineering consulting organizations. The participants from government agencies, universities, and national laboratories were about 10% each. The workshop included a keynote address, 35 technical papers, and vendor's equipment demonstrations. The technical papers described the state-of-the-art in the areas of recent utility digital upgrades such as digital feedwater controllers, steam generator level controllers, integrated plant computer systems, computer aided diagnostics, automated testing and surveillance and other applications. A group of technical papers presented the ongoing B ampersand W PWR integrated plant control system prototype developments with the triple redundant advanced digital control system. Several international papers from France, Japan and U.K. presented their programs on advance power plant design and applications. Significant advances in the control and automation technologies such as adaptive controls, self-tuning methods, neural networks and expert systems were presented by developers, universities, and national laboratories. Individual papers are indexed separately

  15. Hardware design of a microcomputer controlled diagnostic vacuum controller

    International Nuclear Information System (INIS)

    Marsala, R.J.

    1983-01-01

    The TFTR diagnostic vacuum controller (DVC) has been designed and built to control and monitor the pumps, valves and gauges which comprise a diagnostic vacuum system. The DVC is a microcomputer based self-contained controller with battery backup which may be controlled manually from front panel controls or remotely via CICADA. The DVC implements all pump and valve sequencing and provides protection against incorrect operation. There are presently two versions of the DVC operating on TFTR and a third version being used on the S-1 machine

  16. A self-adaptive metamaterial beam with digitally controlled resonators for subwavelength broadband flexural wave attenuation

    Science.gov (United States)

    Li, Xiaopeng; Chen, Yangyang; Hu, Gengkai; Huang, Guoliang

    2018-04-01

    Designing lightweight materials and/or structures for broadband low-frequency noise/vibration mitigation is an issue of fundamental importance both practically and theoretically. In this paper, by leveraging the concept of frequency-dependent effective stiffness control, we numerically and experimentally demonstrate, for the first time, a self-adaptive metamaterial beam with digital circuit controlled mechanical resonators for strong and broadband flexural wave attenuation at subwavelength scales. The digital controllers that are capable of feedback control of piezoelectric shunts are integrated into mechanical resonators in the metamaterial, and the transfer function is semi-analytically determined to realize an effective bending stiffness in a quadratic function of the wave frequency for adaptive band gaps. The digital as well as analog control circuits as the backbone of the system are experimentally realized with the guarantee stability of the whole electromechanical system in whole frequency regions, which is the most challenging problem so far. Our experimental results are in good agreement with numerical predictions and demonstrate the strong wave attenuation in almost a three times larger frequency region over the bandwidth of a passive metamaterial. The proposed metamaterial could be applied in a range of applications in the design of elastic wave control devices.

  17. Control system of digital x-ray systems by quality parameters

    International Nuclear Information System (INIS)

    Balashov, S.V.; Kovalenko, Yu.N.

    2013-01-01

    The paper proposed a control system of X-ray digital equipment on quality indicators. Two basic parameters were determined: image quality and patients' radiation load. A method for monitoring these indicators is proposed. The criterion of equipment suitability is to obtain control digital X-ray images of diagnostically acceptable quality at a fixed low entrance dose in the plane of the digital detector. It is shown that the control system of X-ray digital equipment based on indicators of quality is the most appropriate in situations of deficit of financial resources, since minimizing the costs for the purchase and running of control systems, does not require highly skilled technical personnel, and reduces the duration of the equipment inspection. (authors)

  18. Technical self reliance of digital safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Dong Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Kook Hun [Doosan Heavy Industries and Construction, Changwon (Korea, Republic of); Choi, Seung Gap [POSCON, Pohang (Korea, Republic of)

    2009-04-15

    This paper summarizes the development results of the Korea Nuclear Instrumentation and Control System (KNICS) project sponsored by the Korean government. In this project, Man Machine Interface System (MMIS) architecture, two digital platforms, and several control systems are developed. One platform is a programmable Logic Controller (PLC) for a safety system and another platform is a Distributed Control System (DCS) for a non safety system. With the POSAFE Q PLC, a Reactor Protection System (RPS) and an Engineered Safety Feature Component Control System (ESF CCS) are developed. A Power Control System (PCS) is developed based on the DCS. The safety grade platform and the digital safety systems obtained approval for the Topical Report from the Korean regulatory body in February of 2009. Also a Korean utility and a vendor company determined KNICS results to apply them to the planned Nuclear Power Plant (NPP) in March 2009. This paper introduces the technical self reliance experiences of the safety grade platform and the digital safety systems developed in the KNICS R and D project.

  19. Diagnostic Efficiency in Digital Pathology: A Comparison of Optical Versus Digital Assessment in 510 Surgical Pathology Cases.

    Science.gov (United States)

    Mills, Anne M; Gradecki, Sarah E; Horton, Bethany J; Blackwell, Rebecca; Moskaluk, Christopher A; Mandell, James W; Mills, Stacey E; Cathro, Helen P

    2018-01-01

    Prior work has shown that digital images and microscopic slides can be interpreted with comparable diagnostic accuracy. Although accuracy has been well-validated, the interpretative time for digital images has scarcely been studied and concerns about efficiency remain a major barrier to adoption. We investigated the efficiency of digital pathology when compared with glass slide interpretation in the diagnosis of surgical pathology biopsy and resection specimens. Slides were pulled from 510 surgical pathology cases from 5 organ systems (gastrointestinal, gynecologic, liver, bladder, and brain). Original diagnoses were independently confirmed by 2 validating pathologists. Diagnostic slides were scanned using the Philips IntelliSite Pathology Solution. Each case was assessed independently on digital and optical by 3 reading pathologists, with a ≥6 week washout period between modalities. Reading pathologists recorded assessment times for each modality; digital times included time to load the case. Diagnostic accuracy was determined based on whether a rendered diagnosis differed significantly from the original diagnosis. Statistical analysis was performed to assess for differences in interpretative times across modalities. All 3 reading pathologists showed comparable diagnostic accuracy across optical and digital modalities (mean major discordance rates with original diagnosis: 4.8% vs. 4.4%, respectively). Mean assessment times ranged from 1.2 to 9.1 seconds slower on digital versus optical. The slowest reader showed a significant learning effect during the course of the study so that digital assessment times decreased over time and were comparable with optical times by the end of the series. Organ site and specimen type did not significantly influence differences in interpretative times. In summary, digital image reading times compare favorably relative to glass slides across a variety of organ systems and specimen types. Mean increase in assessment time is 4

  20. Implementation considerations for digital control systems in power plants: Final report

    International Nuclear Information System (INIS)

    Shah, S.C.; Lehman, L.L.; Sarchet, M.M.

    1988-09-01

    Conversion of nuclear power plants fron analog to digital control systems will require careful design, testing, and integration of the control algorithms, the software which implements the algorithms, the digital instrumentation, the digital communications network, and analog/digital device interfaces. Digital control systems are more flexible than their analog counterparts, and therefore greater attention must be paid by the customer to all stages of the control system design process. This flexibility also provides the framework for development of significant safety and reliability are inherant aspects of the chosen design processes. Digital control algorithms are capable of improving their performance by on-line self-tuning of the control parameters. It is therefore incumbant on system designers to choose self-tuning algorithms for power plant control. Implementation of these algorithms in software required a careful software design and development process to minimize errors in interpretation of the engineering design and prevent the inclusion of programming errors during software production. Digital control system and communications software must exhibit sufficient ''fault tolerance'' to maintain some level of safe plant operation or execute a safe plant shutdown in the event of both hard equipment failures and the appearance of software design faults. A number of standardized digital communications protocols are available to designers of digital control systems. These standardized digital communications protocols provide reliable fault tolerant communication between all digital elements of the plant control system and can be implemented redundantly to further enhance power plant operational safety. 5 refs., 11 figs., 1 tab

  1. Does Digital Game Interactivity Always Promote Self-Efficacy?

    Science.gov (United States)

    Lee, Yu-Hao

    2015-11-01

    Interactive digital games can promote self-efficacy by engaging players in enactive and observational learning. However, interactivity does not always lead to greater self-efficacy. Important constructs in social cognitive theory, such as performance outcome and perceived similarity, are often not accounted for in studies that have tested the effect of digital game interactivity on self-efficacy. This study assessed the effects of interactive digital games compared with passive digital games based on video comparison, a common experimental design used to test the effect of digital game interactivity on self-efficacy. In addition, this study also evaluated player performance and measured perceived similarity to the observed player. Findings suggested that in general, digital game interactivity predicted higher self-efficacy compared with noninteractive passive games. However, in the noninteractive conditions, the effects of performance on self-efficacy were moderated by perceived similarity between the observer and the observed player. When the observed player was perceived to be similar to the observer, the effects of performance on self-efficacy were comparable to the interactive game, but when the observed player was perceived as dissimilar to the observer, observing the dissimilar player failed to increase observer self-efficacy. Implications for interactivity manipulations and game developers are discussed.

  2. Target Diagnostic Control System Implementation for the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R.T.; Kamperschroer, J.H.; Lagin, L.J.; Nelson, J.R.; O'Brien, D.W.

    2010-01-01

    The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A Diagnostic Control System (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Windows XP processor and Java application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in XML. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

  3. Diagnostic image quality of video-digitized chest images

    International Nuclear Information System (INIS)

    Winter, L.H.; Butler, R.B.; Becking, W.B.; Warnars, G.A.O.; Haar Romeny, B. ter; Ottes, F.P.; Valk, J.-P.J. de

    1989-01-01

    The diagnostic accuracy obtained with the Philips picture archiving and communications subsystem was investigated by means of an observer performance study using receiver operating characteristic (ROC) analysis. The image qualities of conventional films and video digitized images were compared. The scanner had a 1024 x 1024 x 8 bit memory. The digitized images were displayed on a 60 Hz interlaced display monitor 1024 lines. Posteroanterior (AP) roetgenograms of a chest phantom with superimposed simulated interstitial pattern disease (IPD) were produced; there were 28 normal and 40 abnormal films. Normal films were produced by the chest phantom alone. Abnormal films were taken of the chest phantom with varying degrees of superimposed simulated intersitial disease (PND) for an observer performance study, because the results of a simulated interstitial pattern disease study are less likely to be influenced by perceptual capabilities. The conventional films and the video digitized images were viewed by five experienced observers during four separate sessions. Conventional films were presented on a viewing box, the digital images were displayed on the monitor described above. The presence of simulated intersitial disease was indicated on a 5-point ROC certainty scale by each observer. We analyzed the differences between ROC curves derived from correlated data statistically. The mean time required to evaluate 68 digitized images is approximately four times the mean time needed to read the convential films. The diagnostic quality of the video digitized images was significantly lower (at the 5% level) than that of the conventional films (median area under the curve (AUC) of 0.71 and 0.94, respectively). (author). 25 refs.; 2 figs.; 4 tabs

  4. Proposed Diagnostic Criteria for the DSM-5 of Nonsuicidal Self-Injury in Female Adolescents: Diagnostic and Clinical Correlates

    Directory of Open Access Journals (Sweden)

    Tina In-Albon

    2013-01-01

    Full Text Available Nonsuicidal self-injury (NSSI is included as conditions for further study in the DSM-5. Therefore, it is necessary to investigate the proposed diagnostic criteria and the diagnostic and clinical correlates for the validity of a diagnostic entity. The authors investigated the characteristics of NSSI disorder and the proposed diagnostic criteria. A sample of 73 female inpatient adolescents and 37 nonclinical adolescents (aged 13 to 19 years was recruited. Patients were classified into 4 groups (adolescents with NSSI disorder, adolescents with NSSI without impairment/distress, clinical controls without NSSI, and nonclinical controls. Adolescents were compared on self-reported psychopathology and diagnostic cooccurrences. Results indicate that adolescents with NSSI disorder have a higher level of impairment than adolescents with other mental disorders without NSSI. Most common comorbid diagnoses were major depression, social phobia, and PTSD. There was some overlap of adolescents with NSSI disorder and suicidal behaviour and borderline personality disorder, but there were also important differences. Results further suggest that the proposed DSM-5 diagnostic criteria for NSSI are useful and necessary. In conclusion, NSSI is a highly impairing disorder characterized by high comorbidity with various disorders, providing further evidence that NSSI should be a distinct diagnostic entity.

  5. Conversion of a servomanipulator from analog to digital control

    International Nuclear Information System (INIS)

    Killough, S.M.; Martin, H.L.; Hamel, W.R.

    1986-01-01

    Oak Ridge National Laboratory (ORNL) has developed expertise in computer control of force-reflecting master/slave servomanipulators as a result of research for the Consolidated Fuel Reprocessing Program. These computer control capabilities have been applied to a commercially available servomanipulator, the TeleOperator Systems SM-229. All of the servo drive and control circuitry has been replaced with commercially available digital controls and amplifiers, and a customer software - package has been developed at ORNL. This conversion to digital computer control resulted in significant improvements in force-reflection characteristics, ease of operation, diagnostic capabilities, indexing features, and potential increased reliability. The system will be used at the Tokamak Fusion Test Reactor at the Princeton Plasma Physics Laboratory (PPPL) for maintenance demonstrations

  6. Preservice Teachers and Self-Assessing Digital Competence

    Science.gov (United States)

    Maderick, Joseph A.; Zhang, Shaoan; Hartley, Kendall; Marchand, Gwen

    2016-01-01

    This study compares matched surveys of subjective self-assessment and objective assessment on seven domains of digital competence for preservice teachers at a large Southwest public university. The results, consistent with earlier studies, confirm that the participating preservice teachers inaccurately self-assessed their digital competence. The…

  7. Target diagnostic control system implementation for the National Ignition Facility (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R. T.; Kamperschroer, J. H.; Lagin, L. J.; Nelson, J. R.; O' Brien, D. W. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2010-10-15

    The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

  8. Target diagnostic control system implementation for the National Ignition Facility (invited)

    International Nuclear Information System (INIS)

    Shelton, R. T.; Kamperschroer, J. H.; Lagin, L. J.; Nelson, J. R.; O'Brien, D. W.

    2010-01-01

    The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

  9. Impact of Digital Tooth Preparation Evaluation Technology on Preclinical Dental Students' Technical and Self-Evaluation Skills.

    Science.gov (United States)

    Gratton, David G; Kwon, So Ran; Blanchette, Derek; Aquilino, Steven A

    2016-01-01

    The aim of this study was to evaluate the effect of digital tooth preparation imaging and evaluation technology on dental students' technical abilities, self-evaluation skills, and the assessment of their simulated clinical work. A total of 80 second-year students at one U.S. dental school were assigned to one of three groups: control (n=40), E4D Compare (n=20), and Sirona prepCheck (n=20). Students in the control group were taught by traditional teaching methodologies, and the technology-assisted groups received both traditional training and supplementary feedback from the corresponding digital system. Three outcomes were measured: faculty technical score, self-evaluation score, and E4D Compare scores at 0.30 mm tolerance. Correlations were determined between the groups' scores from visual assessment and self-evaluation and between the visual assessment and digital scores. The results showed that the visual assessment and self-evaluation scores did not differ among groups (p>0.05). Overall, correlations between visual and digital assessment scores were modest though statistically significant (5% level of significance). These results suggest that the use of digital tooth preparation evaluation technology did not impact the students' prosthodontic technical and self-evaluation skills. Visual scores given by faculty and digital assessment scores correlated moderately in only two instances.

  10. Digital limiter for a self-excited loop

    International Nuclear Information System (INIS)

    Joshi, G.; Singh, P.; Agarwal, V.; Kumar, G.

    2015-01-01

    Limiter is one of the main signal processing modules of a self-excited loop (SEL). It plays a crucial role in initiating and stabilizing the amplitude of the RF field in a free running SEL. In a recently reported implementation of a self excited loop in digital domain, the limiter has been realized at based band in the form of a feedback loop. This feedback loop stabilizes the amplitude of the RF phasor present at its input without affecting its phase. In the present work we study the suitability of this implementation of limiter through analysis and simulations. An approximate equivalent model of an SEL, incorporating the digital limiter, is created in analog domain. It is demonstrated that even in the presence for large transients, such as, at the start up of oscillations, SEL continues to exhibit smooth and predictable response. In free running mode of operation the coupling from loop oscillation frequency change to resonator field amplitude change is absent, thus avoiding instability due to electro-mechanical coupling. In the locked mode, the transmission of amplitude jitter through the limiter is far exceeded by that through the controller gain thereby keeping the behavior of the digital SEL close to its analog counterpart. (author)

  11. Teaching perceptual skills in clinical diagnostics using digital media

    NARCIS (Netherlands)

    Scheiter, Katharina; Jarodzka, Halszka

    2011-01-01

    Scheiter, K., & Jarodzka, H. (2011, May). Teaching perceptual skills in clinical diagnostics using digital media. Presentation at the 2nd International Conference “Research in Medical Education”: Shaping diamonds from bench to bedside, Universität Tübingen.

  12. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Kiran, E-mail: kkpatel@ipr.res.in; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-11-15

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.

  13. GPIB based instrumentation and control system for ADITYA Thomson Scattering Diagnostic

    International Nuclear Information System (INIS)

    Patel, Kiran; Pillai, Vishal; Singh, Neha; Chaudhary, Vishnu; Thomas, Jinto; Kumar, Ajai

    2016-01-01

    The ADITYA Thomson Scattering Diagnostic is a single point Ruby laser based system with a spectrometer for spectral dispersion and photomultiplier tubes for the detection of scattered light. The system uses CAMAC (Computer Automated Measurement And Control) based control and data acquisition system, which synchronizes the Ruby laser, detectors and the digitizer. Previously used serial based CAMAC controller is upgraded to GPIB (General Purpose Interface Bus) based CAMAC controller for configuration and data transfer. The communication protocols for different instruments are converted to a single GPIB based for better interface. The entire control and data acquisition program is developed on LabVIEW platform for versatile operation of diagnostics with improved user friendly GUI (Graphical User Interfaces) and allows user to remotely update the laser firing time with respect to the plasma shot. The software is in handshake with the Tokamak main control program through network to minimize manual interventions for the operation of the diagnostics. The upgraded system improved the performance of the diagnostics in comparison to earlier in terms of better data transmission rate, easy to maintain and program is upgradable.

  14. Digital image acquisition in the X-ray diagnostics. Its influence on the patients' exposure

    International Nuclear Information System (INIS)

    Hoberg, Bernd; Voigt, Stefan

    2012-01-01

    Radiation exposure in the classical X-ray diagnostics was continuously reduced during the past years. The annual report 2009 of the Bundesamt fuer Strahlenschutz (BfS) shows that 46% of the radiological examinations in Germany concern the skeleton, the lungs and the digestive and urogenital tract. The respective radiation dose is only 20% of the total dose of the public from X-ray diagnostic measures. Considering computerized tomography, angiography and interventional radiology, that amount to about 10% of the radiological examinations, their dose percentage reaches about 80%. Therefore, the emphasis of modern radiation protection has to be targeted to digital techniques in the future X-ray diagnostics. The authors describe digital detectors, direct and indirect digitalized image receivers, flat-panel detectors and dynamic detectors.

  15. Development in Diagnostics Application to Control Advanced Tokamak Plasma

    International Nuclear Information System (INIS)

    Koide, Y.

    2008-01-01

    For continuous operation expected in DEMO, all the plasma current must be non-inductively driven, with self-generated neoclassical bootstrap current being maximized. The control of such steady state high performance tokamak plasma (so-called 'Advanced Tokamak Plasma') is a challenge because of the strong coupling between the current density, the pressure profile and MHD stability. In considering diagnostic needs for the advanced tokamak research, diagnostics for MHD are the most fundamental, since discharges which violate the MHD stability criteria either disrupt or have significantly reduced confinement. This report deals with the development in diagnostic application to control advanced tokamak plasma, with emphasized on recent progress in active feedback control of the current profile and the pressure profile under DEMO-relevant high bootstrap-current fraction. In addition, issues in application of the present-day actuators and diagnostics for the advanced control to DEMO will be briefly addressed, where port space for the advanced control may be limited so as to keep sufficient tritium breeding ratio (TBR)

  16. A digitized wide range channel for new instrumentation and control system of PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Zareen Khan Abdul Jalil Khan; Izhar Abu Hussin; Mohd Idris Taib; Nurfarhana Ayuni Joha; Roslan Md Dan

    2010-01-01

    Wide Range Channel is one of very important part of Reactor Instrumentation and Control system. Current system is using all analog system. The main functions of the new system are to provide Wide-log power and Multi-range linear power. The other functions are to provide Percent power and Power rate of change. The linear power level range is up to 125 % and the log power system to cover from below source level to 150 %. The main function of digital signal processor is for pulse shaping, pulse counting and root mean square signal processing. The system employs automatic on-line self diagnostics and calibration verification. (author)

  17. On the mental life and spatial symptoms of the digital self. Interview with Angeliki Malakasioti by Chris H. Gray

    Directory of Open Access Journals (Sweden)

    Angeliki Malakasioti

    2013-08-01

    Full Text Available From the celestial to the cyberspatial sphere and from imaginary beings to self-constructed online personas, symptom constellations are representing our ‘way of being’. Using this as a vaulting point, Angeliki Malakasioti is taking symptom representation a step further, towards the reasons of manifestation, towards observation and refection on the phenomena of digital experience. Her research is a diagnostic experiment and at the same time a theoretical as well as an artistic body of work that comments on the mental qualities of the cyborg when inhabiting cyberspace. Aspects of the digital self are discussed and its symptoms are interpreted into spatial qualities; into imaginary semi-living beings and intimate non-spaces. 

  18. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    International Nuclear Information System (INIS)

    Lee, Wan; Lee, Byung Do

    2003-01-01

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  19. Quality control in diagnostic radiology - patient dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  20. Image enhancement of digital periapical radiographs according to diagnostic tasks

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung

    2014-01-01

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  1. Image enhancement of digital periapical radiographs according to diagnostic tasks

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung [Dept. of Oral and Maxillofacial Radiology, Dankook University College of Dentistry, Cheonan (Korea, Republic of)

    2014-03-15

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  2. Diagnostic accuracy and recall rates for digital mammography and digital mammography combined with one-view and two-view tomosynthesis: results of an enriched reader study.

    Science.gov (United States)

    Rafferty, Elizabeth A; Park, Jeong Mi; Philpotts, Liane E; Poplack, Steven P; Sumkin, Jules H; Halpern, Elkan F; Niklason, Loren T

    2014-02-01

    The purpose of this study was to compare two methods of combining tomosynthesis with digital mammography by assessing diagnostic accuracy and recall rates for digital mammography alone and digital mammography combined with one-view tomosynthesis and two-view tomosynthesis. Three hundred ten cases including biopsy-proven malignancies (51), biopsy-proven benign findings (47), recalled screening cases (138), and negative screening cases (74) were reviewed by 15 radiologists sequentially using digital mammography, adding one-view tomosynthesis, and then two-view tomosynthesis. Cases were assessed for recall and assigned a BI-RADS score and probability of malignancy for each imaging method. Diagnostic accuracy was assessed using receiver operating characteristic (ROC) analysis. Screening recall rates were compared using pooled logistical regression analysis. A p value of tomosynthesis, and DM plus two-view tomosynthesis was 0.828, 0.864, and 0.895, respectively. Both one-view and two-view tomosynthesis plus DM were significantly better than DM alone (Δ AUCs 0.036 [p = 0.009] and 0.068 [p tomosynthesis, and DM plus two-view tomosynthesis were 44.2%, 27.2%, and 24.0%, respectively. Combined with DM, one-view and two-view tomosynthesis both showed significantly lower noncancer recall rates than digital mammography alone (p tomosynthesis showed a significantly lower recall rate than digital mammography with one-view tomosynthesis (p tomosynthesis compared with digital mammography alone. Compared with digital mammography, diagnostic sensitivity for invasive cancers increased with the addition of both one-view (Δ12.0%, p tomosynthesis. The addition of one-view tomosynthesis to conventional digital mammography improved diagnostic accuracy and reduced the recall rate; however, the addition of two-view tomosynthesis provided twice the performance gain in diagnostic accuracy while further reducing the recall rate.

  3. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R; O'Brien, D; Nelson, J; Kamperschroer, J

    2007-01-01

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the deployed

  4. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R; O' Brien, D; Nelson, J; Kamperschroer, J

    2007-05-07

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the

  5. Improvement of a Pneumatic Control Valve with Self-Holding Function

    Science.gov (United States)

    Dohta, Shujiro; Akagi, Tetsuya; Kobayashi, Wataru; Shimooka, So; Masago, Yusuke

    2017-10-01

    The purpose of this study is to develop a small-sized, lightweight and low-cost control valve with low energy consumption and to apply it to the assistive system. We have developed some control valves; a tiny on/off valve using a vibration motor, and an on/off valve with self-holding function. We have also proposed and tested the digital servo valve with self-holding function using permanent magnets and a small-sized servo motor. In this paper, in order to improve the valve, an analytical model of the digital servo valve is proposed. And the simulated results by using the analytical model and identified parameters were compared with the experimental results. Then, the improved digital servo valve was designed based on the calculated results and tested. As a result, we realized the digital servo valve that can control the flow rate more precisely while maintaining its volume and weight compared with the previous valve. As an application of the improved valve, a position control system of rubber artificial muscle was built and the position control was performed successfully.

  6. Two applications of direct digital down converters in beam diagnostics

    International Nuclear Information System (INIS)

    Powers, Tom; Flood, Roger; Hovater, Curt; Musson, John

    2000-01-01

    The technologies of direct digital down converters, digital frequency synthesis, and digital signal processing are being used in many commercial applications. Because of this commercialization, the component costs are being reduced to the point where they are economically viable for large scale accelerator applications. This paper will discuss two applications of these technologies to beam diagnostics. In the first application the combination of direct digital frequency synthesis and direct digital down converters are coupled with digital signal processor technology in order to maintain the stable gain environment required for a multi-electrode beam position monitoring system. This is done by injecting a CW reference signal into the electronics as part of the front-end circuitry. In the second application direct digital down converters are used to provide a novel approach to the measurement of beam intensity using cavity current monitors. In this system a pair of reference signals are injected into the cavity through an auxiliary port. The beam current is then calculated as the ratio of the beam signal divided by the average of the magnitude of the two reference signals

  7. Trait Self-esteem Moderates Decreases in Self-control Following Rejection: An Information-processing Account

    Science.gov (United States)

    Vandellen, Michelle; Knowles, Megan L.; Krusemark, Elizabeth; Sabet, Raha F.; Campbell, W. Keith; McDowell, Jennifer E.; Clementz, Brett A.

    2012-01-01

    In the current paper, the authors posit that trait self-esteem moderates the relationship between social rejection and decrements in self-control, propose an information-processing account of trait self-esteem’s moderating influence and discuss three tests of this theory. The authors measured trait self-esteem, experimentally manipulated social rejection and assessed subsequent self-control in Studies 1 and 2. Additionally, Study 3 framed a self-control task as diagnostic of social skills to examine motivational influences. Together, the results reveal that rejection impairs self-control, but only among low self-esteem individuals. Moreover, this decrement in self-control only emerged when the task had no social implications—suggesting that low self-esteem individuals exert effort on tasks of social value and are otherwise preoccupied with belonging needs when completing nonsocial tasks. PMID:22611304

  8. Trait Self-esteem Moderates Decreases in Self-control Following Rejection: An Information-processing Account.

    Science.gov (United States)

    Vandellen, Michelle; Knowles, Megan L; Krusemark, Elizabeth; Sabet, Raha F; Campbell, W Keith; McDowell, Jennifer E; Clementz, Brett A

    2012-03-01

    In the current paper, the authors posit that trait self-esteem moderates the relationship between social rejection and decrements in self-control, propose an information-processing account of trait self-esteem's moderating influence and discuss three tests of this theory. The authors measured trait self-esteem, experimentally manipulated social rejection and assessed subsequent self-control in Studies 1 and 2. Additionally, Study 3 framed a self-control task as diagnostic of social skills to examine motivational influences. Together, the results reveal that rejection impairs self-control, but only among low self-esteem individuals. Moreover, this decrement in self-control only emerged when the task had no social implications-suggesting that low self-esteem individuals exert effort on tasks of social value and are otherwise preoccupied with belonging needs when completing nonsocial tasks.

  9. A Comparative Study on Diagnostic Accuracy of Colour Coded Digital Images, Direct Digital Images and Conventional Radiographs for Periapical Lesions – An In Vitro Study

    Science.gov (United States)

    Mubeen; K.R., Vijayalakshmi; Bhuyan, Sanat Kumar; Panigrahi, Rajat G; Priyadarshini, Smita R; Misra, Satyaranjan; Singh, Chandravir

    2014-01-01

    Objectives: The identification and radiographic interpretation of periapical bone lesions is important for accurate diagnosis and treatment. The present study was undertaken to study the feasibility and diagnostic accuracy of colour coded digital radiographs in terms of presence and size of lesion and to compare the diagnostic accuracy of colour coded digital images with direct digital images and conventional radiographs for assessing periapical lesions. Materials and Methods: Sixty human dry cadaver hemimandibles were obtained and periapical lesions were created in first and second premolar teeth at the junction of cancellous and cortical bone using a micromotor handpiece and carbide burs of sizes 2, 4 and 6. After each successive use of round burs, a conventional, RVG and colour coded image was taken for each specimen. All the images were evaluated by three observers. The diagnostic accuracy for each bur and image mode was calculated statistically. Results: Our results showed good interobserver (kappa > 0.61) agreement for the different radiographic techniques and for the different bur sizes. Conventional Radiography outperformed Digital Radiography in diagnosing periapical lesions made with Size two bur. Both were equally diagnostic for lesions made with larger bur sizes. Colour coding method was least accurate among all the techniques. Conclusion: Conventional radiography traditionally forms the backbone in the diagnosis, treatment planning and follow-up of periapical lesions. Direct digital imaging is an efficient technique, in diagnostic sense. Colour coding of digital radiography was feasible but less accurate however, this imaging technique, like any other, needs to be studied continuously with the emphasis on safety of patients and diagnostic quality of images. PMID:25584318

  10. Effect of data compression on diagnostic accuracy in digital hand and chest radiography

    Science.gov (United States)

    Sayre, James W.; Aberle, Denise R.; Boechat, Maria I.; Hall, Theodore R.; Huang, H. K.; Ho, Bruce K. T.; Kashfian, Payam; Rahbar, Guita

    1992-05-01

    Image compression is essential to handle a large volume of digital images including CT, MR, CR, and digitized films in a digital radiology operation. The full-frame bit allocation using the cosine transform technique developed during the last few years has been proven to be an excellent irreversible image compression method. This paper describes the effect of using the hardware compression module on diagnostic accuracy in hand radiographs with subperiosteal resorption and chest radiographs with interstitial disease. Receiver operating characteristic analysis using 71 hand radiographs and 52 chest radiographs with five observers each demonstrates that there is no statistical significant difference in diagnostic accuracy between the original films and the compressed images with a compression ratio as high as 20:1.

  11. Diagnostic imaging, a 'parallel' discipline. Can current technology provide a reliable digital diagnostic radiology department

    International Nuclear Information System (INIS)

    Moore, C.J.; Eddleston, B.

    1985-01-01

    Only recently has any detailed criticism been voiced about the practicalities of the introduction of generalised, digital, imaging complexes in diagnostic radiology. Although attendant technological problems are highlighted the authors argue that the fundamental causes of current difficulties are not in the generation but in the processing, filing and subsequent retrieval for display of digital image records. In the real world, looking at images is a parallel process of some complexity and so it is perhaps untimely to expect versatile handling of vast image data bases by existing computer hardware and software which, by their current nature, perform tasks serially. (author)

  12. T-scan III system diagnostic tool for digital occlusal analysis in orthodontics - a modern approach.

    Science.gov (United States)

    Trpevska, Vesna; Kovacevska, Gordana; Benedeti, Alberto; Jordanov, Bozidar

    2014-01-01

    This systematic literature review was performed to establish the mechanism, methodology, characteristics, clinical application and opportunities of the T-Scan III System as a diagnostic tool for digital occlusal analysis in different fields of dentistry, precisely in orthodontics. Searching of electronic databases, using MEDLINE and PubMed, hand searching of relevant key journals, and screening of reference lists of included studies with no language restriction was performed. Publications providing statistically examined data were included for systematic review. Twenty potentially relevant Randomized Controlled Trials (RCTs) were identified. Only ten met the inclusion criteria. The literature demonstrates that using digital occlusal analysis with T-Scan III System in orthodontics has significant advantage with regard to the capability of measuring occlusal parameters in static positions and during dynamic of the mandible. Within the scope of this systematic review, there is evidence to support that T-Scan system is rapid and accurate in identifying the distribution of the tooth contacts and it shows great promise as a clinical diagnostic screening device for occlusion and for improving the occlusion after various dental treatments. Additional clinical studies are required to advance the indication filed of this system. Importance of using digital occlusal T-Scan analysis in orthodontics deserves further investigation.

  13. Effect of verbal persuasion on self-efficacy for pain-related diagnostic sensory testing in individuals with chronic neck pain and healthy controls - a randomized, controlled trial.

    Science.gov (United States)

    Söderlund, Anne; Sterling, Michele

    2016-01-01

    The aim of this study was to investigate the differences in cold pain threshold (CTh), pressure pain threshold (PPT), cold pain tolerance (CPTo) tests, and the level of self-efficacy when self-efficacy for diagnostic sensory testing was manipulated by verbal persuasion before a testing situation in persons with neck pain and in healthy controls. A randomized experimental design was used. Twenty-one healthy volunteers and 22 individuals with either traumatic or nontraumatic chronic neck pain were recruited to participate in the study. The intervention consisted of two experimental verbal persuasion conditions: Increase self-efficacy and Decrease self-efficacy. The PPT was measured using a pressure algometer, the CTh was measured using a thermo test system, and CPTo was measured by submerging the participant's hand in ice water up to the elbow joint. On three occasions, the participants reported their self-efficacy level in performing the sensory tests. In the chronic neck pain group, there were no differences in pain threshold or tolerance. There was a difference in the self-efficacy level after verbal persuasion between the experimental conditions. In the healthy control group, the CThs increased following the condition that aimed to increase self-efficacy. No other differences were observed in the healthy controls. A short verbal persuasion in the form of manipulative instructions seems to have a marginal effect on the individual's self-efficacy levels in the chronic neck pain group and a slight influence on the results of sensory testing in healthy controls.

  14. A malaria diagnostic tool based on computer vision screening and visualization of Plasmodium falciparum candidate areas in digitized blood smears.

    Directory of Open Access Journals (Sweden)

    Nina Linder

    Full Text Available INTRODUCTION: Microscopy is the gold standard for diagnosis of malaria, however, manual evaluation of blood films is highly dependent on skilled personnel in a time-consuming, error-prone and repetitive process. In this study we propose a method using computer vision detection and visualization of only the diagnostically most relevant sample regions in digitized blood smears. METHODS: Giemsa-stained thin blood films with P. falciparum ring-stage trophozoites (n = 27 and uninfected controls (n = 20 were digitally scanned with an oil immersion objective (0.1 µm/pixel to capture approximately 50,000 erythrocytes per sample. Parasite candidate regions were identified based on color and object size, followed by extraction of image features (local binary patterns, local contrast and Scale-invariant feature transform descriptors used as input to a support vector machine classifier. The classifier was trained on digital slides from ten patients and validated on six samples. RESULTS: The diagnostic accuracy was tested on 31 samples (19 infected and 12 controls. From each digitized area of a blood smear, a panel with the 128 most probable parasite candidate regions was generated. Two expert microscopists were asked to visually inspect the panel on a tablet computer and to judge whether the patient was infected with P. falciparum. The method achieved a diagnostic sensitivity and specificity of 95% and 100% as well as 90% and 100% for the two readers respectively using the diagnostic tool. Parasitemia was separately calculated by the automated system and the correlation coefficient between manual and automated parasitemia counts was 0.97. CONCLUSION: We developed a decision support system for detecting malaria parasites using a computer vision algorithm combined with visualization of sample areas with the highest probability of malaria infection. The system provides a novel method for blood smear screening with a significantly reduced need for

  15. Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

    International Nuclear Information System (INIS)

    Lee, Ji Un; Kwon, Ki Jeong; Koh, Kwang Joon

    2004-01-01

    To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities(P<0.05). The kappa value of inter-observer agreement was 0.42(range:0.28-0.60) and intra-observer agreement was 0.57(range:0.44-0.75). There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  16. Use of the target diagnostic control system in the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R; Lagin, L; Nelson, J

    2011-07-25

    The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics including optical backscatter, time-integrated, time resolved and gated X-ray sensors, laser velocity interferometry, and neutron time of flight. Diagnostics to diagnose fusion ignition implosion and neutron emissions have been developed. A Diagnostic Control System (DCS) for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Window XP processor and Java application. Instruments are aggregated as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. During the past several years, over thirty-six diagnostics have been deployed using this architecture in support of the National Ignition Campaign (NIC). The DCS architecture facilitates the expected additions and upgrades to diagnostics as more experiments are performed. This paper presents the DCS architecture, framework and our experiences in using it during the NIC to operate, upgrade and maintain a large set of diagnostic instruments.

  17. Use of the target diagnostic control system in the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R.; Lagin, L.; Nelson, J.

    2011-01-01

    The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics including optical backscatter, time-integrated, time resolved and gated X-ray sensors, laser velocity interferometry, and neutron time of flight. Diagnostics to diagnose fusion ignition implosion and neutron emissions have been developed. A Diagnostic Control System (DCS) for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Window XP processor and Java application. Instruments are aggregated as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. During the past several years, over thirty-six diagnostics have been deployed using this architecture in support of the National Ignition Campaign (NIC). The DCS architecture facilitates the expected additions and upgrades to diagnostics as more experiments are performed. This paper presents the DCS architecture, framework and our experiences in using it during the NIC to operate, upgrade and maintain a large set of diagnostic instruments.

  18. IGENPRO knowledge-based digital system for process transient diagnostics and management

    International Nuclear Information System (INIS)

    Morman, J.A.; Reifman, J.; Vitela, J.E.; Wei, T.Y.C.; Applequist, C.A.; Hippely, P.; Kuk, W.; Tsoukalas, L.H.

    1998-01-01

    Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R and D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module PROMANA to treat unanticipated events and the PROTREN module is being developed to process actual plant data. Achievement of the IGENPRO R and D goals should contribute to the acceptance of knowledge-based digital systems for transient diagnostics and management. (author)

  19. IGENPRO knowledge-based digital system for process transient diagnostics and management

    International Nuclear Information System (INIS)

    Morman, J.A.; Reifman, J.; Wei, T.Y.C.

    1997-01-01

    Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R ampersand D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module PROMANA to treat unanticipated events and the PROTREN module is being developed to process actual plant data. Achievement of the IGENPRO R ampersand D goals should contribute to the acceptance of knowledge-based digital systems for transient diagnostics and management

  20. Digitally Controlled Point of Load Converter with Very Fast Transient Response

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Andersen, Michael Andreas E.

    2007-01-01

    voltage mode control and very fast transient response. The DiSOM modulator is combined with a digital PID compensator algorithm is implemented in a hybrid CPLD/FPGA and is used to control a synchronous Buck converter, which is used in typical Point of Load applications. The computational time is only......This paper presents a new Digital Self-Oscillating Modulator (DiSOM) that allows the duty cycle to be changed instantly. The DiSOM modulator is shown to have variable switching that is a function of the duty cycle. Compared to a more traditional digital PWM modulator based on a counter...... and comparator the DiSOM modulator allows the sampling frequency of the output voltage control loop to be higher than the switching frequency of the power converter, typically a DC/DC converter. The features of the DiSOM modulator makes it possible to design a digitally controlled DC/DC converter with linear...

  1. Diagnostic accuracy in virtual dermatopathology

    DEFF Research Database (Denmark)

    Mooney, E.; Kempf, W.; Jemec, G.B.E.

    2012-01-01

    Background Virtual microscopy is used for teaching medical students and residents and for in-training and certification examinations in the United States. However, no existing studies compare diagnostic accuracy using virtual slides and photomicrographs. The objective of this study was to compare...... diagnostic accuracy of dermatopathologists and pathologists using photomicrographs vs. digitized images, through a self-assessment examination, and to elucidate assessment of virtual dermatopathology. Methods Forty-five dermatopathologists and pathologists received a randomized combination of 15 virtual...... slides and photomicrographs with corresponding clinical photographs and information in a self-assessment examination format. Descriptive data analysis and comparison of groups were performed using a chi-square test. Results Diagnostic accuracy in dermatopathology using virtual dermatopathology...

  2. Digital imaging in diagnostic radiology. Image quality - radiation exposure

    International Nuclear Information System (INIS)

    Schmidt, T.; Stieve, F.E.

    1996-01-01

    The publication contains the 37 lectures of the symposium on digital imaging in diagnostic radiology, held in November 1995 at Kloster Seeon, as well as contributions enhancing the information presented in the lectures. The publication reflects the state of the art in this subject field, discusses future trends and gives recommendations and information relating to current practice in radiology. In-depth information is given about R and D activities for the digitalisation of X-ray pictures and the image quality required to meet the purposes of modern diagnostics. Further aspects encompass radiological protection and dose optimization as well as optimization of examination methods. (vhe) [de

  3. Evaluation of the equine digital flexor tendon sheath using diagnostic ultrasound and contrast radiography

    International Nuclear Information System (INIS)

    Redding, W.R.

    1994-01-01

    This study was designed to evaluate the normal anatomy of the digital flexor tendon sheath using contrast radiography and diagnostic ultrasound. Iodinated contrast medium was injected into eight cadaver limbs and the limbs immediately frozen. Lateromedial and dorsopalmar/plantar radiographs were made. These limps were then cut transversely and proximal to distal radiographs of each slab were made. This cross sectional contrast methodology allowed the visualization of the relative size and shape of the superficial and deep digital flexor tendons as well as the potential space taken by effusions of the digital flexor tendon sheath. The second part of the study used twelve live animals with normal digital flexor tendon sheaths. Ultrasonographic measurement of the structures of the digital flexor tendon sheath at each level were compiled. This documented the ability of diagnostic ultrasound to image: 1) the superficial and deep digital flexor tendons, 2) the proximal and distal ring of the manica flexoria, 3) the straight and oblique sesamoidean ligaments, and 4) the mesotendinous attachments to the superficial and deep flexor tendons. Iodinated contrast medium was then injected into the digital flexor tendon sheath and the ultrasonography repeated. These images were compared with those obtained from contrast radiography and prosections of twenty normal limbs. The iodinated contrast medium enhanced sonographic imaging of the structures of the digital tendon sheath, particularly the abaxial borders of the superficial digital flexor tendon branches and the mesotendinous attachments to the superficial and deep digital flexor tendons

  4. Data handling at EBR-II [Experimental Breeder Reactor II] for advanced diagnostics and control work

    International Nuclear Information System (INIS)

    Lindsay, R.W.; Schorzman, L.W.

    1988-01-01

    Improved control and diagnostics systems are being developed for nuclear and other applications. The Experimental Breeder Reactor II (EBR-II) Division of Argonne National Laboratory has embarked on a project to upgrade the EBR-II control and data handling systems. The nature of the work at EBR-II requires that reactor plant data be readily available for experimenters, and that the plant control systems be flexible to accommodate testing and development needs. In addition, operational concerns require that improved operator interfaces and computerized diagnostics be included in the reactor plant control system. The EBR-II systems have been upgraded to incorporate new data handling computers, new digital plant process controllers, and new displays and diagnostics are being developed and tested for permanent use. In addition, improved engineering surveillance will be possible with the new systems

  5. Digital control card based on digital signal processor

    International Nuclear Information System (INIS)

    Hou Shigang; Yin Zhiguo; Xia Le

    2008-01-01

    A digital control card based on digital signal processor was developed. Two Freescale DSP-56303 processors were utilized to achieve 3 channels proportional- integral-differential regulations. The card offers high flexibility for 100 MeV cyclotron RF system development. It was used as feedback controller in low level radio frequency control prototype, with the feedback gain parameters continuously adjustable. By using high precision analog to digital converter with 500 kHz sampling rate, a regulation bandwidth of 20 kHz was achieved. (authors)

  6. Digital Support Interventions for the Self-Management of Low Back Pain

    DEFF Research Database (Denmark)

    Nicholl, Barbara I; Sandal, Louise Fleng; Stochkendahl, Mette Jensen

    2017-01-01

    BACKGROUND: Low back pain (LBP) is a common cause of disability and is ranked as the most burdensome health condition globally. Self-management, including components on increased knowledge, monitoring of symptoms, and physical activity, are consistently recommended in clinical guidelines as cost......-effective strategies for LBP management and there is increasing interest in the potential role of digital health. OBJECTIVE: The study aimed to synthesize and critically appraise published evidence concerning the use of interactive digital interventions to support self-management of LBP. The following specific...... questions were examined: (1) What are the key components of digital self-management interventions for LBP, including theoretical underpinnings? (2) What outcome measures have been used in randomized trials of digital self-management interventions in LBP and what effect, if any, did the intervention have...

  7. Design considerations for a digital feedback system to control self-bunching in ion-storage rings

    Directory of Open Access Journals (Sweden)

    V. Ziemann

    2001-04-01

    Full Text Available We discuss the feasibility of a digital feedback system to cure self-bunching of the electron-cooled coasting ion beam in ion-storage rings such as CELSIUS [S. Holm, A. Johansson, S. Kullander, and D. Reistad, Phys. Scr. 34, 513–532 (1986]. Such a system is based on a fast digital filter that acts as a tunable artificial wake potential. It may also aid stable operation of accumulator rings for future spallation neutron sources or heavy ion rings used for inertial fusion energy production.

  8. TFTR diagnostic vacuum controller

    International Nuclear Information System (INIS)

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller

  9. Distributed digital real-time control system for the TCV tokamak and its applications

    NARCIS (Netherlands)

    Anand, H.; Galperti, C.; Coda, S.; Duval, B.P.; Felici, F.; Blanken, T.; Maljaars, E.; Moret, J.M.; Sauter, O.; Goodman, T.P.; Kim, D.

    2017-01-01

    A key feature of the new digital plasma control system installed on the TCV (Tokamak à Configuration Variable) tokamak is its possibility to rapidly design, test and deploy real-time algorithms. It accommodates hundreds of diagnostic inputs and actuator outputs, and offers the possibility to design

  10. Digital spot mammography using an add-on upright unit: diagnostic application in daily practice

    International Nuclear Information System (INIS)

    Mesurolle, Benoit; Mignon, Francois; Ariche-Cohen, Michele; Kao, Ellen; Gagnon, Jean H.; Goumot, Pierre-Alain

    2004-01-01

    Introduction: To present the use of digital spot mammography (DSM) in a diagnostic practice. Methods and patients: Digital spot images of 779 women requiring a spot compression or a spot magnification view were collected. The digital images were acquired on a digital spot upright unit using a 61 mmx61 mm field of view. Lesions reported included masses, calcifications, and areas of distortions. Results: 1065 lesions required additional views with DSM. Lesions reported included masses (n=113), masses and microcalcifications (n=53), spiculated masses (n=34), architectural distortions (n=16), and microcalcifications (n=849). DSMs were considered to be adequate in 97.7% of patients. Unsatisfactory exams resulted from difficulties encountered in targeting the area of interest at the beginning of our experience. Conclusion: DSM, most commonly used to perform interventional procedures, can also be used in a diagnostic practice taking advantage of post-processing of images not available with conventional spot compression and magnification

  11. A Versatile Image Processor For Digital Diagnostic Imaging And Its Application In Computed Radiography

    Science.gov (United States)

    Blume, H.; Alexandru, R.; Applegate, R.; Giordano, T.; Kamiya, K.; Kresina, R.

    1986-06-01

    In a digital diagnostic imaging department, the majority of operations for handling and processing of images can be grouped into a small set of basic operations, such as image data buffering and storage, image processing and analysis, image display, image data transmission and image data compression. These operations occur in almost all nodes of the diagnostic imaging communications network of the department. An image processor architecture was developed in which each of these functions has been mapped into hardware and software modules. The modular approach has advantages in terms of economics, service, expandability and upgradeability. The architectural design is based on the principles of hierarchical functionality, distributed and parallel processing and aims at real time response. Parallel processing and real time response is facilitated in part by a dual bus system: a VME control bus and a high speed image data bus, consisting of 8 independent parallel 16-bit busses, capable of handling combined up to 144 MBytes/sec. The presented image processor is versatile enough to meet the video rate processing needs of digital subtraction angiography, the large pixel matrix processing requirements of static projection radiography, or the broad range of manipulation and display needs of a multi-modality diagnostic work station. Several hardware modules are described in detail. For illustrating the capabilities of the image processor, processed 2000 x 2000 pixel computed radiographs are shown and estimated computation times for executing the processing opera-tions are presented.

  12. Additional diagnostic value of digital radiology in plantar fasciitis diagnosis

    Directory of Open Access Journals (Sweden)

    Marcel Prasetyo

    2017-08-01

    Full Text Available Background: Ultrasonography (USG is regarded as the gold standard to differentiate normal plantar fascia and plantar fasciitis. Conventional radiography or plain X-ray is typically used to exclude differential diagnosis. Lately, conventional radiography has been digitalized and leads to better visualization of the soft tissue. However, it is not known whether digital radiography evaluation for calcaneus area, both qualitative and quantitative, has a similar diagnostic value as USG findings. Therefore, this study aimed to evaluate whether there is a strong correlation between digital radiographic and USG findings for diagnosing plantar fasciitis.Methods: This is a cross sectional study examining adult patients (>18 years old presenting with inferior heel pain. Plantar aponeurosis thickness was measured by digital radiography and ultrasonography; measurement was performed three times in each modality, and the average value was recorded. Fat stranding, presence of calcaneal enthesophyte, and microfracture were also evaluated in digital radiography. Measurement results were classified into plantar fasciitis diagnosis using the cut-off value 4 mm.Results: There was no significant correlation between plantar aponeurosis thickness measured by digital radiography and by ultrasonography (r=0.069, p=0.688. There was no significant association between plantar fasciitis diagnosis by digital radiography and ultrasonography (p=0.162. However, digital radiography showed good sensitivity to detect plantar fasciitis using a cut-off value of >4 mm plantar fascia thickness.Conclusion: Digital radiography might be used to aid definitive diagnosis for plantar fasciitis.

  13. Diagnostic Strategy in APR1400

    International Nuclear Information System (INIS)

    Kim, Dongyoung; Kim, Jonghyun

    2013-01-01

    These features may bring out changes in operator tasks, changing the characteristics of tasks, or creating new tasks. Diagnostic strategy for identifying anomaly may be different especially in APR1400 from that in the analog control room due to the change of human-system interface, i.e. alarm system and display system. Since the first plant of APR1400 is being built at this moment, it is not known what strategies the operators will adopt in diagnosis tasks in the new operating environment. In this light, this paper aims at investigating operator's diagnostic strategies which are appropriate for APR1400. In order to collect data, several different approaches which are complementary are used to identify diagnostic strategies in the digital control room: analysis on audio/video recording of operation, observation in the simulator, and interview with the operators. The result shows that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of strategies, mostly, by getting more support from the computerized system. This paper investigated how the digitalized control room may influence operator's diagnostic strategies. Several different approaches, i. e., audio/video record, observation of training, and the interview with operators, were used to gather information about the operator's behaviors. As a conclusion, this paper figured out that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of the strategies, mostly, by getting more support from the computerized system. The operators interviewed also commented that the diagnosis in the APR1400 is quicker, more correct, and easier, compared with the analog control room

  14. Front-end data reduction of diagnostic signals by real-time digital filtering

    International Nuclear Information System (INIS)

    Zasche, D.; Fahrbach, H.U.; Harmeyer, E.

    1984-01-01

    Diagnostic measurements on a fusion plasma with high resolution in space, time and signal amplitude involve handling large amounts of data. In the design of the soft-X-ray pinhole camera diagnostic for JET (100 detectors in 2 cameras) a new approach to this problem was found. The analogue-to-digital conversion is performed continuously at the highest sample rate of 200 kHz, lower sample rates (10 kHz, 1 kHz, 100 Hz) are obtained by real-time digital filters which calculate weighted averages over consecutive samples and are undersampled at their outputs to reduce the data rate. At any time, the signals from all detectors are available at all possible data rates in ring buffers. The appropriate data rate can always be recorded on demand. (author)

  15. Diagnostic reference levels in digital mammography: a systematic review

    International Nuclear Information System (INIS)

    Suleiman, Moayyad E.; Brennan, Patrick C.; McEntee, Mark F.

    2015-01-01

    This study aims to review the literature on existing diagnostic reference levels (DRLs) in digital mammography and methodologies for establishing them. To this end, a systematic search through Medline, Cinahl, Web of Science, Scopus and Google scholar was conducted using search terms extracted from three terms: DRLs, digital mammography and breast screen. The search resulted in 1539 articles of which 22 were included after a screening process. Relevant data from the included studies were summarised and analysed. Differences were found in the methods utilised to establish DRLs including test subjects types, protocols followed, conversion factors employed, breast compressed thicknesses and percentile values adopted. These differences complicate comparison of DRLs among countries; hence, an internationally accepted protocol would be valuable so that international comparisons can be made. (authors)

  16. Introduction of digital control

    International Nuclear Information System (INIS)

    Kim, Sang Jin

    1988-01-01

    This book is one of mechatronics series. It deals with digital control, which includes what is digital control?, display way of control system, output of primary system, secondary system like example of system and display way of the system, stabilizing of control system such as method to decide stability and system out of control, displaying equation of state into vector, good control such as the right characteristic, transient behavior and design of position control system using DC servo motor.

  17. Diagnostics for real-time plasma control in PBX-M

    Science.gov (United States)

    Kaita, R.; Batha, S.; Bell, R. E.; Bernabei, S.; Hatcher, R.; Kozub, T.; Kugel, H.; Levinton, F.; Okabayashi, M.; Sesnic, S.; von Goeler, S.; Zolfaghari, A.; PBX-M Group

    1995-01-01

    An important issue for future tokamaks is real-time plasma control for the avoidance of magnetohydrodynamic instabilities and other applications that require detailed plasma profile and fluctuation data. Although measurements from diagnostics providing this information require significantly more processing than magnetic flux data, recent advancements could make them practical for adjusting operational settings for plasma heating and current drive systems as well as field coil currents. On the Princeton Beta Experiment-Modification (PBX-M), the lower hybrid current drive phasing can be varied during a plasma shot using digitally programmable ferrite phase shifters, and neural beam functions can be fully computer controlled. PBX-M diagnostics that may be used for control purposes include motional Stark-effect polarimetry for magnetic field pitch angle profiles, soft x-ray arrays for plasma position control and the separation of βp from li, hard x-ray detectors for energetic electron distributions, a multichannel electron cyclotron emission radiometer for ballooning mode identification, and passive plate eddy current monitors for kink stabilization. We will describe the present status of these systems on PBX-M, and discuss their suitability for feedback applications.

  18. Diagnostics for real-time plasma control in PBX-M

    International Nuclear Information System (INIS)

    Kaita, R.; Batha, S.; Bell, R.E.; Bernabei, S.; Hatcher, R.; Kozub, T.; Kugel, H.; Levinton, F.; Okabayashi, M.; Sesnic, S.; Goeler, S. von; Zolfaghari, A.

    1995-01-01

    An important issue for future tokamaks is real-time plasma control for the avoidance of magnetohydrodynamic instabilities and other applications that require detailed plasma profile and fluctuation data. Although measurements from diagnostics providing this information require significantly more processing than magnetic flux data, recent advancements could make them practical for adjusting operational settings for plasma heating and current drive systems as well as field coil currents. On the Princeton Beta Experiment-Modification (PBX-M), the lower hybrid current drive phasing can be varied during a plasma shot using digitally programmable ferrite phase shifters, and neural beam functions can be fully computer controlled. PBX-M diagnostics that may be used for control purposes include motional Stark-effect polarimetry for magnetic field pitch angle profiles, soft x-ray arrays for plasma position control and the separation of β p from l i , hard x-ray detectors for energetic electron distributions, a multichannel electron cyclotron emission radiometer for ballooning mode identification, and passive plate eddy current monitors for kink stabilization. We will describe the present status of these systems on PBX-M, and discuss their suitability for feedback applications

  19. Architectures and Algorithms for Control and Diagnostics of Coupled-Bunch Instabilities in Circular Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Teytelman, Dmitry

    2003-07-08

    Modern light sources and circular colliders employ large numbers of high-intensity particle bunches in order to achieve high luminosity. The electromagnetic coupling of bunches via resonant structures causes coherent instabilities at high beam currents. Achieving high luminosity requires the control of such unstable motion. Feedback control is challenging due to wideband nature of the problem with up to 250 MHz bandwidths required. This thesis presents digital signal processing architectures and diagnostic techniques for control of longitudinal and transverse coupled-bunch instabilities. Diagnostic capabilities integrated into the feedback system allow one to perform fast transient measurements of unstable dynamics by perturbing the beam from the controlled state via feedback and recording the time-domain response. Such measurements enable one to thoroughly characterize plant (beam) dynamics as well as performance of the feedback system. Beam dynamics can change significantly over the operating range of accelerator currents and energies . Here we present several methods for design of robust stabilizing feedback controllers. Experimental results from several accelerators are presented. A new baseband architecture for transverse feedback is described that compactly implements the digital processing functions using field-programmable gate array devices. The architecture is designed to be software configurable so that the same hardware can be used for instability control in different accelerators.

  20. Architectures and Algorithms for Control and Diagnostics of Coupled-Bunch Instabilities in Circular Accelerators

    International Nuclear Information System (INIS)

    Teytelman, Dmitry

    2003-01-01

    Modern light sources and circular colliders employ large numbers of high-intensity particle bunches in order to achieve high luminosity. The electromagnetic coupling of bunches via resonant structures causes coherent instabilities at high beam currents. Achieving high luminosity requires the control of such unstable motion. Feedback control is challenging due to wideband nature of the problem with up to 250 MHz bandwidths required. This thesis presents digital signal processing architectures and diagnostic techniques for control of longitudinal and transverse coupled-bunch instabilities. Diagnostic capabilities integrated into the feedback system allow one to perform fast transient measurements of unstable dynamics by perturbing the beam from the controlled state via feedback and recording the time-domain response. Such measurements enable one to thoroughly characterize plant (beam) dynamics as well as performance of the feedback system. Beam dynamics can change significantly over the operating range of accelerator currents and energies . Here we present several methods for design of robust stabilizing feedback controllers. Experimental results from several accelerators are presented. A new baseband architecture for transverse feedback is described that compactly implements the digital processing functions using field-programmable gate array devices. The architecture is designed to be software configurable so that the same hardware can be used for instability control in different accelerators

  1. Diagnostic Strategy in APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dongyoung; Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-05-15

    These features may bring out changes in operator tasks, changing the characteristics of tasks, or creating new tasks. Diagnostic strategy for identifying anomaly may be different especially in APR1400 from that in the analog control room due to the change of human-system interface, i.e. alarm system and display system. Since the first plant of APR1400 is being built at this moment, it is not known what strategies the operators will adopt in diagnosis tasks in the new operating environment. In this light, this paper aims at investigating operator's diagnostic strategies which are appropriate for APR1400. In order to collect data, several different approaches which are complementary are used to identify diagnostic strategies in the digital control room: analysis on audio/video recording of operation, observation in the simulator, and interview with the operators. The result shows that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of strategies, mostly, by getting more support from the computerized system. This paper investigated how the digitalized control room may influence operator's diagnostic strategies. Several different approaches, i. e., audio/video record, observation of training, and the interview with operators, were used to gather information about the operator's behaviors. As a conclusion, this paper figured out that the digital control room introduces new strategies in the diagnosis, compared with the analog control room, and also changed the characteristics of the strategies, mostly, by getting more support from the computerized system. The operators interviewed also commented that the diagnosis in the APR1400 is quicker, more correct, and easier, compared with the analog control room.

  2. Precision digital control systems

    Science.gov (United States)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  3. Deciphering the Theobroma cacao self-incompatibility system: from genomics to diagnostic markers for self-compatibility.

    Science.gov (United States)

    Lanaud, Claire; Fouet, Olivier; Legavre, Thierry; Lopes, Uilson; Sounigo, Olivier; Eyango, Marie Claire; Mermaz, Benoit; Da Silva, Marcos Ramos; Loor Solorzano, Rey Gaston; Argout, Xavier; Gyapay, Gabor; Ebaiarrey, Herman Ebai; Colonges, Kelly; Sanier, Christine; Rivallan, Ronan; Mastin, Géraldine; Cryer, Nicholas; Boccara, Michel; Verdeil, Jean-Luc; Efombagn Mousseni, Ives Bruno; Peres Gramacho, Karina; Clément, Didier

    2017-10-13

    Cocoa self-compatibility is an important yield factor and has been described as being controlled by a late gameto-sporophytic system expressed only at the level of the embryo sac. It results in gametic non-fusion and involves several loci. In this work, we identified two loci, located on chromosomes 1 and 4 (CH1 and CH4), involved in cocoa self-incompatibility by two different processes. Both loci are responsible for gametic selection, but only one (the CH4 locus) is involved in the main fruit drop. The CH1 locus acts prior to the gamete fusion step and independently of the CH4 locus. Using fine-mapping and genome-wide association studies, we focused analyses on restricted regions and identified candidate genes. Some of them showed a differential expression between incompatible and compatible reactions. Immunolocalization experiments provided evidence of CH1 candidate genes expressed in ovule and style tissues. Highly polymorphic simple sequence repeat (SSR) diagnostic markers were designed in the CH4 region that had been identified by fine-mapping. They are characterized by a strong linkage disequilibrium with incompatibility alleles, thus allowing the development of efficient diagnostic markers predicting self-compatibility and fruit setting according to the presence of specific alleles or genotypes. SSR alleles specific to self-compatible Amelonado and Criollo varieties were also identified, thus allowing screening for self-compatible plants in cocoa populations. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  4. Estimation of reliability on digital plant protection system in nuclear power plants using fault simulation with self-checking

    International Nuclear Information System (INIS)

    Lee, Jun Seok; Kim, Suk Joon; Seong, Poong Hyun

    2004-01-01

    Safety-critical digital systems in nuclear power plants require high design reliability. Reliable software design and accurate prediction methods for the system reliability are important problems. In the reliability analysis, the error detection coverage of the system is one of the crucial factors, however, it is difficult to evaluate the error detection coverage of digital instrumentation and control system in nuclear power plants due to complexity of the system. To evaluate the error detection coverage for high efficiency and low cost, the simulation based fault injections with self checking are needed for digital instrumentation and control system in nuclear power plants. The target system is local coincidence logic in digital plant protection system and a simplified software modeling for this target system is used in this work. C++ based hardware description of micro computer simulator system is used to evaluate the error detection coverage of the system. From the simulation result, it is possible to estimate the error detection coverage of digital plant protection system in nuclear power plants using simulation based fault injection method with self checking. (author)

  5. Rolls-Royce digital Rod Control System

    International Nuclear Information System (INIS)

    Pouillot, M.

    2010-01-01

    Full text of publication follows: Rolls-Royce has developed a new generation of Rod Control System, based on 40 years of experience. The fifth-generation Rod Control System (RCS) from Rolls-Royce offers a reliable, modular design with adaptability to your preferred platform, for modernization projects or new reactors. Flexible implementation provides the option for you to keep existing cabinets, which permits you to optimize installation approach. Main features for the power part: - Control Rod Drive Mechanism (CRDM) type: 3-coil. - Independent control of each sub-bank. - Each sub-bank is controlled by a cycler unit and 3 identical power racks, each including 4 identical power modules and a common power-supply module. - Coil-per-coil digital control: each power module embeds power-conversion, current-control, and current-monitoring functions for one coil. Control and monitoring are carried out by separate electronics in the module. Current is digitized and fully monitored by means of min-max templates. - A double-hold function is included: a power module assigned to a gripper will activate its coil if a fault risking to cause a reactor trip occurs. - Power modules are standardized, hot-pluggable and self-configured: a power module includes a set of parameters for each type of coil SG, MG, LC. The module recognizes the rack it is plugged in, and chooses automatically parameters to be used. Main benefits: - Reduced operational, maintenance, training, and inventory costs: standardization of power modules and integration of control and monitoring on the same PC-card lead to a drastic reduction of spare part types, and simplification of the system. - Easy maintenance: - Replacement of a power module solves nearly all failures due to current control or monitoring for a coil. It is done instantly thanks to hot-plug capability. - On the front plate of power-modules, LEDs provide useful information for diagnostic: current setpoint from cycler, output current bar

  6. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    Energy Technology Data Exchange (ETDEWEB)

    Axelsson, B.; Hansson, I.B. [Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Boden, K.; Witt, H.H. [Department of Diagnostic Radiology, Karolinska Hospital, Stockholm (Sweden); Fransson, S.G. [Department of Thoracic Radiology, University Hospital, Linkoeping (Sweden); Persliden, J. [Department of Radiation Physics, University Hospital, Linkoeping (Sweden)

    2000-08-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm{sup 2}) for the fully digital technique compared to the others (analogue 6.8 Gycm{sup 2}, analogue+digital 3.6 Gycm{sup 2}). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  7. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    International Nuclear Information System (INIS)

    Axelsson, B.; Hansson, I.B.; Boden, K.; Witt, H.H.; Fransson, S.G.; Persliden, J.

    2000-01-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm 2 ) for the fully digital technique compared to the others (analogue 6.8 Gycm 2 , analogue+digital 3.6 Gycm 2 ). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  8. Learning Digital Test and Diagnostics via Internet

    Directory of Open Access Journals (Sweden)

    Heinz-Dietrich Wuttke

    2007-02-01

    Full Text Available An environment targeted to e-learning is presented for teaching design and test of electronic systems. The environment consists of a set of Java applets, and of web based access to the hardware equipments, which can be used in the classroom, for learning at home, in laboratory research and training, or for carrying out testing of students during exams. The tools support university courses on digital electronics, computer hardware, testing and design for testability to learn by hands-on exercises how to design digital systems, how to make them testable, how to build self-testing systems, how to generate test patterns, how to analyze the quality of tests, and how to localize faults in hardware. The tasks chosen for hands-on training represent simultaneously research problems, which allow to fostering in students critical thinking, problem solving skills and creativity.

  9. Digital self-promotion for the underdog author: creative opportunities and experimentation

    OpenAIRE

    Flahive, G.

    2017-01-01

    This paper addresses a lack of originality in the online self-promotion of many mid-list, indie and self-published authors, investigating the strategies of authors who are making more creative use of digital technologies for their self-promotion. This research provides a practical point of guidance to other authors of fiction wishing to innovate in this way. The literature review provides an overview of changes in global media consumption following the digital revolution. Th...

  10. Effect of verbal persuasion on self-efficacy for pain-related diagnostic sensory testing in individuals with chronic neck pain and healthy controls – a randomized, controlled trial

    Directory of Open Access Journals (Sweden)

    Söderlund A

    2016-03-01

    Full Text Available Anne Söderlund,1 Michele Sterling,2 1Physiotherapy, School of Health, Care and Social Welfare, Mälardalen University, Västerås, Sweden; 2Centre for National Research on Disability and Rehabilitation Medicine (CONROD, Menzies Health Institute Queensland, Griffith University, Parklands, Australia Abstract: The aim of this study was to investigate the differences in cold pain threshold (CTh, pressure pain threshold (PPT, cold pain tolerance (CPTo tests, and the level of self-efficacy when self-efficacy for diagnostic sensory testing was manipulated by verbal persuasion before a testing situation in persons with neck pain and in healthy controls. A randomized experimental design was used. Twenty-one healthy volunteers and 22 individuals with either traumatic or nontraumatic chronic neck pain were recruited to participate in the study. The intervention consisted of two experimental verbal persuasion conditions: Increase self-efficacy and Decrease self-efficacy. The PPT was measured using a pressure algometer, the CTh was measured using a thermo test system, and CPTo was measured by submerging the participant's hand in ice water up to the elbow joint. On three occasions, the participants reported their self-efficacy level in performing the sensory tests. In the chronic neck pain group, there were no differences in pain threshold or tolerance. There was a difference in the self-efficacy level after verbal persuasion between the experimental conditions. In the healthy control group, the CThs increased following the condition that aimed to increase self-efficacy. No other differences were observed in the healthy controls. A short verbal persuasion in the form of manipulative instructions seems to have a marginal effect on the individual's self-efficacy levels in the chronic neck pain group and a slight influence on the results of sensory testing in healthy controls. Keywords: pressure pain threshold, cold pain threshold, cold pain tolerance, self

  11. Method for fault diagnosis of digital control systems in nuclear power plant

    International Nuclear Information System (INIS)

    Suzuki, Satoshi; Nagaoka, Yukio; Ohga, Yukiharu; Ito, Tetsuo

    1990-01-01

    This paper presents a method for localizing faulty components of control systems by replaceable parts such as print boards and cables, in a large scale plant like a nuclear power plant. Most of today's control systems form a distributed configuration including many digital controllers interconnected by data communication networks. Usually, to localize the faulty components in nuclear plant control systems, suspected faulty components are narrowed down by executing manual tests to examine whether the objects are normal or abnormal based on design documents and personnel know-how, besides the uses of self-diagnosis functions built into the control systems. In the present method, procedures of various tests including the know-how and checking of self-diagnosis functions are provided as knowledge of tests. The tests to be executed is determined by considering failure probabilities of objects, and easiness and effectiveness of testing. Then, the suspects are narrowed down sequentially based on the test result. In checking feasibility of this diagnosis method for a simulated control system, intended faults are satisfactorily localized. This method is confirmed to be practicable for diagnosis of large scale digital control systems. (author)

  12. Implementation of digital control and protection systems of China advanced research reactor

    International Nuclear Information System (INIS)

    Zeng Hai; Jin Huajin; Xu Qiguo; Zhang Mingkui

    2005-01-01

    China Advanced Research Reactor (CARR), a reactor of the 21st century with high performance is being constructed in China. The requirements of reliability and stability on the control and protection (c and p) system are the main points raised. Especially, with the development of digital technology, the c and p system of CARR is demanded to match the trend of digitization in the field of reactor control. The c and p system, including reactor protection system, reactor monitoring and control system, reactor power regulating system, and the mitigation system for ATWS (Anticipate Transient Without Scram), adopts digital technology, and the digital display screen will replace the analog panels in the main control room. The c and p system of CARR adopts redundant technology with 2 or 3 redundant channels to improve the system reliability. The 10/100 Mbps self-adaptive redundant optic fiber industry Ethernet ring network is used to interlink operator workstations, supervisor workstation, and I/O control stations. Commercial grade equipment with mature experience in industrial application are applied to the c and p system of CARR, which have high reliability, good interchangeability, and is easily purchased, the software-developing tools fully match the international industry standards. The realization of digital c and p system of CARR will promote the progress of digital control technology for reactors in China, and certainly become a technical basic platform for developing informational and intelligent reactors in China. (authors)

  13. Design concepts for a nuclear digital instrumentation and control system platform

    International Nuclear Information System (INIS)

    Ou, T. C.; Chen, C. K.; Chen, P. J.; Shyu, S. S.; Lee, C. L.; Hsieh, S. F.

    2010-10-01

    The objective of this paper is to present the development results of the nuclear instrumentation and control system in Taiwan. As the Taiwan nuclear power plants age, the need to consider upgrading of both their safety and non-safety-related instrumentation and control systems becomes more urgent. Meanwhile, the digital instrumentation and control system that is based on current fast evolving electronic and information technologies are difficult to maintain effectively. Therefore, Institute of Nuclear Energy Research was made a decision to promote the Taiwan Nuclear Instrumentation and Control System project to collaborate with domestic electronic industry to establish self-reliant capabilities on the design, manufacturing, and application of nuclear instrumentation and control systems with newer technology. In the case of safety-related applications like nuclear instrumentation and control, safety-oriented quality control is required. In order to establish a generic qualified digital platform, the world-wide licensing experience should be considered in the licensing process. This paper describes the qualification and certification tools by IEC 61508 for design and development of safety related equipment and explains the basis for many decisions made while performing the digital upgrade. (Author)

  14. Digital systems to acquire radiological imaging. Characteristics and quality control; Sistemas digitales de adquisicion de imagenes radiograficas. Caracteristicas y Control de Calidad

    Energy Technology Data Exchange (ETDEWEB)

    Torres Cabrera, R.; Hernando Gonzalez, I.

    2006-07-01

    Due to its special characteristics, quality control in digital radiographic systems is very important, even more than in conventional film-screen systems. Differences between digital and analogical images,a in terms of dynamics range, spatial and contrast resolution, and the flexibility of data post-processing require some actions to maintain clinical images in an optimum quality level. Revision 1 of the Spanish Protocol of Quality Control in Diagnostic Radiology includes a chapter dedicated to the quality control of these digital systems for the acquisition of radiographic images. In this paper the different parameters for quality control procedures are described. Also some difficulties to be concerned about (absence of levels of tolerance, access to the raw-data images and related information, availability of use anthropomorphic phantoms, etc, etc) are noted, as well as the most significant aspects of the differences in relation to the ana logical systems. (Author) 15 refs.

  15. Distributed digital real-time control system for TCV tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Le, H.B. [École Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association EURATOM-Confédération Suisse, CH-1015 Lausanne (Switzerland); Felici, F. [Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Paley, J.I.; Duval, B.P.; Moret, J.-M.; Coda, S.; Sauter, O.; Fasel, D.; Marmillod, P. [École Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association EURATOM-Confédération Suisse, CH-1015 Lausanne (Switzerland)

    2014-03-15

    Highlights: • A new distributed digital control system for the TCV tokamak has been commissioned. • Data is shared in real-time between all nodes using the reflective memory. • The customised Linux OS allows achieving deterministic and low latency behaviour. • The control algorithm design in Simulink together with the automatic code generation using Embedded Coder allow rapid algorithm development. • Controllers designed outside the TCV environment can be ported easily. • The previous control system functions have been emulated and improved. • New capabilities include MHD control, profile control, equilibrium reconstruction. - Abstract: A new digital feedback control system (named the SCD “Système de Contrôle Distribué”) has been developed, integrated and used successfully to control TCV (Tokamak à Configuration Variable) plasmas. The system is designed to be modular, distributed, and scalable, accommodating hundreds of diagnostic inputs and actuator outputs. With many more inputs and outputs available than previously possible, it offers the possibility to design advanced control algorithms with better knowledge of the plasma state and to coherently control all TCV actuators, including poloidal field (PF) coils, gas valves, the gyrotron powers and launcher angles of the electron cyclotron heating and current drive system (ECRH/ECCD) together with diagnostic triggering signals. The system consists of multiple nodes; each is a customised Linux desktop or embedded PC which may have local ADC and DAC cards. Each node is also connected to a memory network (reflective memory) providing a reliable, deterministic method of sharing memory between all nodes. Control algorithms are programmed as block diagrams in Matlab-Simulink providing a powerful environment for modelling and control design. The C code is generated automatically from the Simulink block diagram and compiled, with the Simulink Embedded Coder (SEC, formerly Real-Time Workshop Embedded

  16. Interferometric Reflectance Imaging Sensor (IRIS—A Platform Technology for Multiplexed Diagnostics and Digital Detection

    Directory of Open Access Journals (Sweden)

    Oguzhan Avci

    2015-07-01

    Full Text Available Over the last decade, the growing need in disease diagnostics has stimulated rapid development of new technologies with unprecedented capabilities. Recent emerging infectious diseases and epidemics have revealed the shortcomings of existing diagnostics tools, and the necessity for further improvements. Optical biosensors can lay the foundations for future generation diagnostics by providing means to detect biomarkers in a highly sensitive, specific, quantitative and multiplexed fashion. Here, we review an optical sensing technology, Interferometric Reflectance Imaging Sensor (IRIS, and the relevant features of this multifunctional platform for quantitative, label-free and dynamic detection. We discuss two distinct modalities for IRIS: (i low-magnification (ensemble biomolecular mass measurements and (ii high-magnification (digital detection of individual nanoparticles along with their applications, including label-free detection of multiplexed protein chips, measurement of single nucleotide polymorphism, quantification of transcription factor DNA binding, and high sensitivity digital sensing and characterization of nanoparticles and viruses.

  17. Pre-Service Teacher Self-Efficacy in Digital Technology

    Science.gov (United States)

    Lemon, Narelle; Garvis, Susanne

    2016-01-01

    Self-efficacy is an important motivational construct for primary school teachers (teachers of children aged 5-12 years) within Australia. Teacher self-efficacy beliefs will determine the level of teacher confidence and competence to engage with a task. In this study, we explore engagement with digital technology and the associated learning and…

  18. Diagnostic Accuracy of CBCT with Different Voxel Sizes and Intraoral Digital Radiography for Detection of Periapical Bone Lesions: An Ex-Vivo Study

    Directory of Open Access Journals (Sweden)

    Shirin Sakhdari

    2016-10-01

    Full Text Available Objectives: This study sought to assess the diagnostic accuracy of cone beam computed tomography (CBCT with different voxel sizes and intraoral digital radiography with photostimulable phosphor (PSP plate for detection of periapical (PA bone lesions.Materials and Methods: In this ex vivo diagnostic study, one-millimeter defects were created in the alveolar sockets of 15 bone blocks, each with two posterior teeth. A no-defect control group was also included. Digital PA radiographs with PSP plates and CBCT scans with 200, 250 and 300μ voxel sizes were obtained. Four observers evaluated the possibility of lesion detection using a 5-point scale. Sensitivity, specificity, positive predictive value (PPV and negative predicative value (NPV were analyzed using one-way ANOVA and Tamhane’s post hoc test. Kappa and weighted kappa statistics were applied to assess intraobserver and interobserver agreements.Results: Cochrane Q test showed no significant difference between PSP and CBCT imaging modalities in terms of kappa and weighted kappa statistics (P=0.675. The complete sensitivity and complete NPV for 200 and 250 μ voxel sizes were higher than those of 300 μ voxel size and digital radiography (P<0.001. No significant difference was noted in other parameters among other imaging modalities (P=0.403.Conclusions: The results showed that high-resolution CBCT scans had higher diagnostic accuracy than PSP digital radiography for detection of artificially created PA bone lesions. Voxel size (field of view must be taken into account to minimize patient radiation dose.Keywords: Diagnosis; Cone-Beam Computed Tomography; Radiography, Dental, Digital; Periapical Periodontitis

  19. Front-end data reduction of diagnostic signals by real-time digital filtering

    International Nuclear Information System (INIS)

    Zasche, D.; Fahrbach, H.U.; Harmeyer, E.

    1985-01-01

    Diagnostic measurements on a fusion plasma with high resolution in space, time and signal amplitude involve handling large amounts of data. In the design of the soft-X-ray pinhole camera diagnostic for JET (100 detectors in 2 cameras) a new approach to this problem was found. The analogue-to-digital conversion is performed continuously at the highest sample rate of 200 kHz, lower sample rates (10 kHz, 1 kHz, 100 Hz) are obtained by real-time digital filters which calculate weighted averages over consecutive samples and are undersampled at their outputs to reduce the data rate. At any time, the signals from all detectors are available at all possible data rates in ring buffers. Thus the appropriate data rate can always be recorded on demand (preprogrammed or triggered by the experiment). With this system a reduction of the raw data by a factor of up to 2000 (typically 200) is possible without severe loss of information

  20. Applications of digital processing for noise removal from plasma diagnostics

    International Nuclear Information System (INIS)

    Kane, R.J.; Candy, J.V.; Casper, T.A.

    1985-01-01

    The use of digital signal techniques for removal of noise components present in plasma diagnostic signals is discussed, particularly with reference to diamagnetic loop signals. These signals contain noise due to power supply ripple in addition to plasma characteristics. The application of noise canceling techniques, such as adaptive noise canceling and model-based estimation, will be discussed. The use of computer codes such as SIG is described. 19 refs., 5 figs

  1. Experience with digital mammography

    Directory of Open Access Journals (Sweden)

    G. P. Korzhenkova

    2011-01-01

    Full Text Available The use of digital techniques in mammography has become a last step for completing the process of digitization in diagnostic imaging. It is assumed that such a spatial decision will be required for digital mammography, as well as for high-resolution intensifying screen-film systems used in conventional mammography and that the digital techniques will be limited by the digitizer pixel size on detecting minor structures, such as microcalcifications. The introduction of digital technologies in mammography involves a tight control over an image and assures its high quality.

  2. [Digital learning object for diagnostic reasoning in nursing applied to the integumentary system].

    Science.gov (United States)

    da Costa, Cecília Passos Vaz; Luz, Maria Helena Barros Araújo

    2015-12-01

    To describe the creation of a digital learning object for diagnostic reasoning in nursing applied to the integumentary system at a public university of Piaui. A methodological study applied to technological production based on the pedagogical framework of problem-based learning. The methodology for creating the learning object observed the stages of analysis, design, development, implementation and evaluation recommended for contextualized instructional design. The revised taxonomy of Bloom was used to list the educational goals. The four modules of the developed learning object were inserted into the educational platform Moodle. The theoretical assumptions allowed the design of an important online resource that promotes effective learning in the scope of nursing education. This study should add value to nursing teaching practices through the use of digital learning objects for teaching diagnostic reasoning applied to skin and skin appendages.

  3. Practical Maintenance of Digital Systems: Guidance to Maximize the Benefits of Digital Technology for the Maintenance of Digital Systems and Plant Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hill, D; Scarola, K

    2004-10-30

    This report presents detailed guidance for the maintenance and testing of modern digital systems. The guidance provides practical means for plants to take advantage of the increased diagnostic and self-test capabilities of these systems. It helps plants avoid mistakes in design and installation that could lead to increased maintenance burden and decreased system reliability and availability.

  4. Practical Maintenance of Digital Systems. Guidance to Maximize the Benefits of Digital Technology for the Maintenance of Digital Systems and Plant Equipment

    International Nuclear Information System (INIS)

    Hill, D.; Scarola, K.

    2004-01-01

    This report presents detailed guidance for the maintenance and testing of modern digital systems. The guidance provides practical means for plants to take advantage of the increased diagnostic and self-test capabilities of these systems. It helps plants avoid mistakes in design and installation that could lead to increased maintenance burden and decreased system reliability and availability

  5. Reactor protection system with automatic self-testing and diagnostic

    International Nuclear Information System (INIS)

    Gaubatz, D.C.

    1996-01-01

    A reactor protection system is disclosed having four divisions, with quad redundant sensors for each scram parameter providing input to four independent microprocessor-based electronic chassis. Each electronic chassis acquires the scram parameter data from its own sensor, digitizes the information, and then transmits the sensor reading to the other three electronic chassis via optical fibers. To increase system availability and reduce false scrams, the reactor protection system employs two levels of voting on a need for reactor scram. The electronic chassis perform software divisional data processing, vote 2/3 with spare based upon information from all four sensors, and send the divisional scram signals to the hardware logic panel, which performs a 2/4 division vote on whether or not to initiate a reactor scram. Each chassis makes a divisional scram decision based on data from all sensors. Automatic detection and discrimination against failed sensors allows the reactor protection system to automatically enter a known state when sensor failures occur. Cross communication of sensor readings allows comparison of four theoretically ''identical'' values. This permits identification of sensor errors such as drift or malfunction. A diagnostic request for service is issued for errant sensor data. Automated self test and diagnostic monitoring, sensor input through output relay logic, virtually eliminate the need for manual surveillance testing. This provides an ability for each division to cross-check all divisions and to sense failures of the hardware logic. 16 figs

  6. PS BOOSTER BEAM TESTS OF THE NEW DIGITAL BEAM CONTROL SYSTEM FOR LEIR

    CERN Document Server

    Angoletta, Maria Elena; Bento, J; De Long, J H; Findlay, A; Matuszkiewicz, P; Pedersen, F; Salom-Sarasqueta, A; CERN. Geneva. AB Department

    2005-01-01

    We have been developing a scaled-down prototype of the new digital beam control and cavity servoing system for CERN’s Low Energy Ion Ring (LEIR) slated for commissioning in 2005. The system’s hardware and software, developed as part of a CERN-BNL collaboration, are based on new all-digital technology already deployed at BNL's AGS Booster. The system relies on VME modules, carrying Digital Signal Processors (DSPs) as well as Field Programmable Gate Arrays (FPGAs), and daughter cards. New concepts deployed include software implementation, through DSPs & FPGAs, of functions traditionally executed by analogue hardware, such as reference-functions and timings generation. Additionally, a user-selectable digital data acquisition functionality provides diagnostic and troubleshoot access points, a new feature which is very useful in a digital system. The scaled-down prototype implements frequency program, radial steering, phase and radial loops capabilities and it has been tested in CERN's PS Booster (PSB) dur...

  7. Evaluation of dimensions of diagnostic X-ray tube focal spots using direct digitalization

    International Nuclear Information System (INIS)

    Costa, Paulo R.; Furquim, Tania A.C.

    1996-01-01

    An image digitalization system is proposed as an alternative method for replacing direct exposure X-ray films on the evaluation of dimensions of diagnostic X-ray tube focal spots. Results of measurements are presented and compared to nominal values

  8. Current status of DIII-D real-time digital plasma control

    International Nuclear Information System (INIS)

    Penaflor, B.G.; Piglowski, D.A.; Ferron, J.R.; Walker, M.L.

    1999-06-01

    This paper describes the current status of real-time digital plasma control for the DIII-D tokamak. The digital plasma control system (PCS) has been in place at DIII-D since the early 1990s and continues to expand and improve in its capabilities to monitor and control plasma parameters for DIII-D fusion science experiments. The PCs monitors over 200 tokamak parameters from the DIII-D experiment using a real-time data acquisition system that acquires a new set of samples once every 60 micros. This information is then used in a number of feedback control algorithms to compute and control a variety of parameters including those affecting plasma shape and position. A number of system related improvements has improved the usability and flexibility of the DIII-D PCS. These include more graphical user interfaces to assist in entering and viewing the large and ever growing number of parameters controlled by the PCS, increased interaction and accessibility from other DIII-D applications, and upgrades to the computer hardware and vended software. Future plans for the system include possible upgrades of the real-time computers, further links to other DIII-D diagnostic measurements such as real-time Thomson scattering analysis, and joint collaborations with other tokamak experiments including the NSTX at Princeton

  9. A Self-Diagnostic System for the M6 Accelerometer

    Science.gov (United States)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  10. Comparing the diagnostic efficacy of full field digital mammography with digital breast tomosynthesis using BIRADS score in a tertiary cancer care hospital.

    Science.gov (United States)

    Singla, Divya; Chaturvedi, Arvind K; Aggarwal, Abhinav; Rao, S A; Hazarika, Dibyamohan; Mahawar, Vivek

    2018-01-01

    Breast cancer is one of the leading cancers in females worldwide, and its incidence has been rising at an exponential pace in the last 10 years even in India. Mammography has been the mainstay for detection of breast cancer over decades and has gradually advanced from screen film to full-field digital mammography. Recently, tomosynthesis has evolved as an advanced imaging investigation for early diagnosis of breast lesions in both diagnostic and screening settings. To compare and evaluate the impact of digital breast tomosynthesis (DBT) compared to full-field digital mammography (FFDM) in the interpretation of BIRADS score in both diagnostic and screening settings. A 1-year prospective longitudinal study was conducted in the Department of Radio-diagnosis in our institute using Hologic Selenia Dimensions for mammography as well as tomosynthesis. One hundred women known or suspected (opportunistic screening) for breast cancer were evaluated either with FFDM alone or both FFDM and DBT. Sensitivity, specificity, positive predictive value, negative predictive value, and P value were used to assess the various diagnostic criteria in our study. Addition of DBT to FFDM results in a statistically significant increase in the sensitivity, specificity, and positive predictive value, and a statistically significant decrease in the false positive rates. Similar results were noted in both diagnostic and screening cases. It was observed that, in most cases, i.e. a total of 47, DBT did not change the BIRADS scoring; however, its addition increased the diagnostic confidence. BIRADS was upgraded and downgraded in 14 and 31 cases, respectively, with the addition of DBT to FFDM. New lesions were seen with addition of DBT to FFDM in 8 cases. Addition of DBT to FFDM results in increase in sensitivity, specificity, positive predictive value, and a statistically significant decrease in false positive rates in both diagnostic and screening cases. As addition of tomosynthesis results in a

  11. Comparing the diagnostic efficacy of full field digital mammography with digital breast tomosynthesis using BIRADS score in a tertiary cancer care hospital

    Directory of Open Access Journals (Sweden)

    Divya Singla

    2018-01-01

    Full Text Available Introduction: Breast cancer is one of the leading cancers in females worldwide, and its incidence has been rising at an exponential pace in the last 10 years even in India. Mammography has been the mainstay for detection of breast cancer over decades and has gradually advanced from screen film to full-field digital mammography. Recently, tomosynthesis has evolved as an advanced imaging investigation for early diagnosis of breast lesions in both diagnostic and screening settings. Aim of Study: To compare and evaluate the impact of digital breast tomosynthesis (DBT compared to full-field digital mammography (FFDM in the interpretation of BIRADS score in both diagnostic and screening settings. Settings and Design: A 1-year prospective longitudinal study was conducted in the Department of Radio-diagnosis in our institute using Hologic Selenia Dimensions for mammography as well as tomosynthesis. Materials and Methods: One hundred women known or suspected (opportunistic screening for breast cancer were evaluated either with FFDM alone or both FFDM and DBT. Sensitivity, specificity, positive predictive value, negative predictive value, and P value were used to assess the various diagnostic criteria in our study. Results: Addition of DBT to FFDM results in a statistically significant increase in the sensitivity, specificity, and positive predictive value, and a statistically significant decrease in the false positive rates. Similar results were noted in both diagnostic and screening cases. It was observed that, in most cases, i.e. a total of 47, DBT did not change the BIRADS scoring; however, its addition increased the diagnostic confidence. BIRADS was upgraded and downgraded in 14 and 31 cases, respectively, with the addition of DBT to FFDM. New lesions were seen with addition of DBT to FFDM in 8 cases. Conclusion: Addition of DBT to FFDM results in increase in sensitivity, specificity, positive predictive value, and a statistically significant

  12. Digital diffraction analysis enables low-cost molecular diagnostics on a smartphone.

    Science.gov (United States)

    Im, Hyungsoon; Castro, Cesar M; Shao, Huilin; Liong, Monty; Song, Jun; Pathania, Divya; Fexon, Lioubov; Min, Changwook; Avila-Wallace, Maria; Zurkiya, Omar; Rho, Junsung; Magaoay, Brady; Tambouret, Rosemary H; Pivovarov, Misha; Weissleder, Ralph; Lee, Hakho

    2015-05-05

    The widespread distribution of smartphones, with their integrated sensors and communication capabilities, makes them an ideal platform for point-of-care (POC) diagnosis, especially in resource-limited settings. Molecular diagnostics, however, have been difficult to implement in smartphones. We herein report a diffraction-based approach that enables molecular and cellular diagnostics. The D3 (digital diffraction diagnosis) system uses microbeads to generate unique diffraction patterns which can be acquired by smartphones and processed by a remote server. We applied the D3 platform to screen for precancerous or cancerous cells in cervical specimens and to detect human papillomavirus (HPV) DNA. The D3 assay generated readouts within 45 min and showed excellent agreement with gold-standard pathology or HPV testing, respectively. This approach could have favorable global health applications where medical access is limited or when pathology bottlenecks challenge prompt diagnostic readouts.

  13. Self-tuning digital Mössbauer detection system

    Science.gov (United States)

    Veiga, A.; Grunfeld, C. M.; Pasquevich, G. A.; Mendoza Zélis, P.; Martínez, N.; Sánchez, F. H.

    2014-01-01

    Long term gamma spectroscopy experiments involving single-channel analyzer equipment depend upon thermal stability of the detector and its associated high-voltage supply. Assuming constant discrimination levels, a drift in the detector gain impacts the output rate, producing an effect on the output spectrum. In some cases (e.g. single-energy resonant absorption experiments) data of interest can be completely lost. We present a digital self-adapting discrimination strategy that tracks emission line shifts using statistical measurements on a predefined region-of-interest of the spectrum. It is developed in the form of a synthesizable module that can be intercalated in the digital processing chain. It requires a moderate to small amount of digital resources and can be easily activated and deactivated.

  14. Digital learning object for diagnostic reasoning in nursing applied to the integumentary system

    Directory of Open Access Journals (Sweden)

    Cecília Passos Vaz da Costa

    Full Text Available Objective: To describe the creation of a digital learning object for diagnostic reasoning in nursing applied to the integumentary system at a public university of Piaui. Method: A methodological study applied to technological production based on the pedagogical framework of problem-based learning. The methodology for creating the learning object observed the stages of analysis, design, development, implementation and evaluation recommended for contextualized instructional design. The revised taxonomy of Bloom was used to list the educational goals. Results: The four modules of the developed learning object were inserted into the educational platform Moodle. The theoretical assumptions allowed the design of an important online resource that promotes effective learning in the scope of nursing education. Conclusion: This study should add value to nursing teaching practices through the use of digital learning objects for teaching diagnostic reasoning applied to skin and skin appendages.

  15. Flexible digital x-ray technology for far-forward remote diagnostic and conformal x-ray imaging applications

    Science.gov (United States)

    Smith, Joseph; Marrs, Michael; Strnad, Mark; Apte, Raj B.; Bert, Julie; Allee, David; Colaneri, Nicholas; Forsythe, Eric; Morton, David

    2013-05-01

    Today's flat panel digital x-ray image sensors, which have been in production since the mid-1990s, are produced exclusively on glass substrates. While acceptable for use in a hospital or doctor's office, conventional glass substrate digital x-ray sensors are too fragile for use outside these controlled environments without extensive reinforcement. Reinforcement, however, significantly increases weight, bulk, and cost, making them impractical for far-forward remote diagnostic applications, which demand rugged and lightweight x-ray detectors. Additionally, glass substrate x-ray detectors are inherently rigid. This limits their use in curved or bendable, conformal x-ray imaging applications such as the non-destructive testing (NDT) of oil pipelines. However, by extending low-temperature thin-film transistor (TFT) technology previously demonstrated on plastic substrate- based electrophoretic and organic light emitting diode (OLED) flexible displays, it is now possible to manufacture durable, lightweight, as well as flexible digital x-ray detectors. In this paper, we discuss the principal technical approaches used to apply flexible display technology to two new large-area flexible digital x-ray sensors for defense, security, and industrial applications and demonstrate their imaging capabilities. Our results include a 4.8″ diagonal, 353 x 463 resolution, flexible digital x-ray detector, fabricated on a 6″ polyethylene naphthalate (PEN) plastic substrate; and a larger, 7.9″ diagonal, 720 x 640 resolution, flexible digital x-ray detector also fabricated on PEN and manufactured on a gen 2 (370 x 470 mm) substrate.

  16. MIDAS, prototype Multivariate Interactive Digital Analysis System, Phase 1. Volume 2: Diagnostic system

    Science.gov (United States)

    Kriegler, F. J.; Christenson, D.; Gordon, M.; Kistler, R.; Lampert, S.; Marshall, R.; Mclaughlin, R.

    1974-01-01

    The MIDAS System is a third-generation, fast, multispectral recognition system able to keep pace with the large quantity and high rates of data acquisition from present and projected sensors. A principal objective of the MIDAS Program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turn-around time and significant gains in throughout. The hardware and software generated in Phase I of the over-all program are described. The system contains a mini-computer to control the various high-speed processing elements in the data path and a classifier which implements an all-digital prototype multivariate-Gaussian maximum likelihood decision algorithm operating 2 x 105 pixels/sec. Sufficient hardware was developed to perform signature extraction from computer-compatible tapes, compute classifier coefficients, control the classifier operation, and diagnose operation. Diagnostic programs used to test MIDAS' operations are presented.

  17. Applying the multi-threat framework of stereotype threat in the context of digital gaming.

    Science.gov (United States)

    Pennington, Charlotte R; Kaye, Linda K; McCann, Joseph J

    2018-01-01

    Females often report experiencing stigmatisation pertaining to their competency in digital gaming communities. Employing the principles of the multi-threat framework of stereotype threat, the current research examined the impact of gender-related stereotypes on females' gaming performance and related self-perceptions. In Experiment 1, 90 females were assigned to one of three conditions in which they were primed that their performance would be either diagnostic of their personal (self-as-target) or gender group's ability (group-as-target) or would be non-diagnostic of gaming ability (control). In Experiment 2, 90 females were primed that their performance would be judged by a group of other females (in-group source) or males (out-group source), or would be non-diagnostic of ability (control). Participants then completed a casual gaming task, as well as measures of competence beliefs, self-efficacy and self-esteem. Findings from Experiment 1 indicate that neither a self-as-target nor a group-as-target stereotype affected significantly gaming performance, or game-related self-efficacy, self-esteem and competency beliefs. Findings from Experiment 2 reveal further that females' gaming performance and associated self-perceptions were not impacted significantly by an in-group or out-group source of stereotype threat. The discussion turns to potential explanations for these findings, proposing that females may not perceive negative gender-gaming stereotypes to be an accurate representation of their personal or social group's gaming ability. We also discuss the implications of the experimental design and difficulty, as well as the potential for domain identification to moderate performance outcomes under stereotype threat.

  18. Applying the multi-threat framework of stereotype threat in the context of digital gaming.

    Directory of Open Access Journals (Sweden)

    Charlotte R Pennington

    Full Text Available Females often report experiencing stigmatisation pertaining to their competency in digital gaming communities. Employing the principles of the multi-threat framework of stereotype threat, the current research examined the impact of gender-related stereotypes on females' gaming performance and related self-perceptions. In Experiment 1, 90 females were assigned to one of three conditions in which they were primed that their performance would be either diagnostic of their personal (self-as-target or gender group's ability (group-as-target or would be non-diagnostic of gaming ability (control. In Experiment 2, 90 females were primed that their performance would be judged by a group of other females (in-group source or males (out-group source, or would be non-diagnostic of ability (control. Participants then completed a casual gaming task, as well as measures of competence beliefs, self-efficacy and self-esteem. Findings from Experiment 1 indicate that neither a self-as-target nor a group-as-target stereotype affected significantly gaming performance, or game-related self-efficacy, self-esteem and competency beliefs. Findings from Experiment 2 reveal further that females' gaming performance and associated self-perceptions were not impacted significantly by an in-group or out-group source of stereotype threat. The discussion turns to potential explanations for these findings, proposing that females may not perceive negative gender-gaming stereotypes to be an accurate representation of their personal or social group's gaming ability. We also discuss the implications of the experimental design and difficulty, as well as the potential for domain identification to moderate performance outcomes under stereotype threat.

  19. Digital Support Interventions for the Self-Management of Low Back Pain: A Systematic Review.

    Science.gov (United States)

    Nicholl, Barbara I; Sandal, Louise F; Stochkendahl, Mette J; McCallum, Marianne; Suresh, Nithya; Vasseljen, Ottar; Hartvigsen, Jan; Mork, Paul J; Kjaer, Per; Søgaard, Karen; Mair, Frances S

    2017-05-21

    Low back pain (LBP) is a common cause of disability and is ranked as the most burdensome health condition globally. Self-management, including components on increased knowledge, monitoring of symptoms, and physical activity, are consistently recommended in clinical guidelines as cost-effective strategies for LBP management and there is increasing interest in the potential role of digital health. The study aimed to synthesize and critically appraise published evidence concerning the use of interactive digital interventions to support self-management of LBP. The following specific questions were examined: (1) What are the key components of digital self-management interventions for LBP, including theoretical underpinnings? (2) What outcome measures have been used in randomized trials of digital self-management interventions in LBP and what effect, if any, did the intervention have on these? and (3) What specific characteristics or components, if any, of interventions appear to be associated with beneficial outcomes? Bibliographic databases searched from 2000 to March 2016 included Medline, Embase, CINAHL, PsycINFO, Cochrane Library, DoPHER and TRoPHI, Social Science Citation Index, and Science Citation Index. Reference and citation searching was also undertaken. Search strategy combined the following concepts: (1) back pain, (2) digital intervention, and (3) self-management. Only randomized controlled trial (RCT) protocols or completed RCTs involving adults with LBP published in peer-reviewed journals were included. Two reviewers independently screened titles and abstracts, full-text articles, extracted data, and assessed risk of bias using Cochrane risk of bias tool. An independent third reviewer adjudicated on disagreements. Data were synthesized narratively. Of the total 7014 references identified, 11 were included, describing 9 studies: 6 completed RCTs and 3 protocols for future RCTs. The completed RCTs included a total of 2706 participants (range of 114

  20. Digital low level RF control system for the DESY TTF VUV-FEL Linac

    International Nuclear Information System (INIS)

    Ayvazyan, V.; Choroba, S.; Matyushin, A.; Moeller, G.; Petrosyan, G.; Rehlich, K.; Simrock, S.N.; Vetrov, P.

    2005-01-01

    In the RF system for the Vacuum Ultraviolet Free Electron Laser (VUV-FEL) Linac each klystron supplies RF power to up to 32 cavities. The superconducting cavities are operated in pulsed mode and high accelerating gradients close to the performance limit. The RF control of the cavity fields to the level of 10 -4 for amplitude and 0.1 degree for phase however presents a significant technical challenge due to the narrow bandwidth of the cavities which results in high sensitivity to perturbations of the resonance frequency by mechanical vibrations (microphonics) and Lorenz force detuning. The VUV-FEL Linac RF control system employs a completely digital feedback system to provide flexibility in the control algorithms, precise calibration of the accelerating field vector-sum, and extensive diagnostics and exception handling capabilities. The RF control algorithm is implemented in DSP (Digital Signal Processor) firmware and DOOCS (Distributed Object Oriented Control System) servers. The RF control system design objectives are discussed. Hardware and software design of the DSP based RF control are presented. (orig.)

  1. Digital low level RF control system for the DESY TTF VUV-FEL Linac

    Energy Technology Data Exchange (ETDEWEB)

    Ayvazyan, V.; Choroba, S.; Matyushin, A.; Moeller, G.; Petrosyan, G.; Rehlich, K.; Simrock, S.N.; Vetrov, P.

    2005-07-01

    In the RF system for the Vacuum Ultraviolet Free Electron Laser (VUV-FEL) Linac each klystron supplies RF power to up to 32 cavities. The superconducting cavities are operated in pulsed mode and high accelerating gradients close to the performance limit. The RF control of the cavity fields to the level of 10{sup -4} for amplitude and 0.1 degree for phase however presents a significant technical challenge due to the narrow bandwidth of the cavities which results in high sensitivity to perturbations of the resonance frequency by mechanical vibrations (microphonics) and Lorenz force detuning. The VUV-FEL Linac RF control system employs a completely digital feedback system to provide flexibility in the control algorithms, precise calibration of the accelerating field vector-sum, and extensive diagnostics and exception handling capabilities. The RF control algorithm is implemented in DSP (Digital Signal Processor) firmware and DOOCS (Distributed Object Oriented Control System) servers. The RF control system design objectives are discussed. Hardware and software design of the DSP based RF control are presented. (orig.)

  2. Digital Living at Home

    DEFF Research Database (Denmark)

    Andersen, Pernille Viktoria Kathja; Christiansen, Ellen Tove

    2013-01-01

    of these user voices has directed us towards a ‘home-keeping’ design discourse, which opens new horizons for design of digital home control systems by allowing users to perform as self-determined controllers and groomers of their habitat. The paper concludes by outlining the implications of a ‘home......Does living with digital technology inevitably lead to digital living? Users talking about a digital home control system, they have had in their homes for eight years, indicate that there is more to living with digital technology than a functional-operational grip on regulation. Our analysis......-keeping’ design discourse....

  3. Digital Pulser for Characterization and Diagnostic of Digital Spectrometers

    International Nuclear Information System (INIS)

    Jordanov, V.T.

    2013-01-01

    The concept and the realization of the digital pulser are presented. The digital pulser is implemented as a functional block of a digital spectrometer. The digital pulser provides noise free and distortion free measurement of the inherent electronic noise of the entire spectroscopy system. The digital pulser is introduced at the end of the signal processing chain and allows separate evaluation of the individual spectroscopy blocks. It offers the ability to characterize and diagnose problems of the digital pulse height analysers by grounding their inputs. The digital pulser does not interfere with the processing of the detector signals and does not contribute to the dead time and the pulse pile-up of the system. The digital pulser peaks are not affected by the presence of detector pulses and are stored in a separate histogram memory leaving the detector spectrum undistorted. (author)

  4. Digital imaging in conventional diagnostic radiology: status and trends

    International Nuclear Information System (INIS)

    Pfeiler, M.; Marhoff, P.; Schipper, P.

    1984-01-01

    Digital techniques, i.e. techniques using microcomputers of minicomputers, are getting increasingly common in so-called conventional radiography. These nonreconstructive techniques are referred to here as 'digital, direct-imaging radiography' in order to contrast them with the reconstructive techniques of computerized tomography. Digitalisation of imaging and image processing operation and control will change the jobs of the radiologist and radiological assistants in such manner that only X-ray units with film-foil systems or with X-ray image intensification should be classified as conventional systems. Digital and conventional systems differ in that digital techniques imply the possibility of establishing data pools which may eventually be developed into a digital image interconnection and archiving system. The authors first describe the general system in which the digital imaging systems must be integrated on a medium-term and long-term basis and then proceed to discuss digital imaging and image processing in some more detail. (orig./WU) [de

  5. Experience of digital control systems in Scandinavian BWRs

    International Nuclear Information System (INIS)

    Rydahl, I.

    1989-01-01

    Since 1984 digital control systems have been in operation in various Scandinavian BWRs. Examples of such digital control systems are: dual microprocessor based system for complete control of radwaste plant, three channel recirculation control system, and three channel feedwater control system. This paper describes Swedish development from one channel through three channel analog control systems to digital systems. The author describes experience of digital control systems during design, testing, commissioning and operation. The main benefits of digital compared with analog technology are discussed. Especially the outstanding facility of using a built-in process simulator for commissioning and tuning. The use of digital technology in nuclear safety system and future plans are dealt with

  6. Self-adapted thermocouple-diagnostic complex

    International Nuclear Information System (INIS)

    Alekseev, S.V.; Grankovskij, K.Eh.; Olejnikov, P.P.; Prijmak, S.V.; Shikalov, V.F.

    2003-01-01

    A self-adapted thermocouple-diagnostic complex (STDC) for obtaining the reliable data on the coolant temperature in the reactors of NPP is described. The STDC in based on the thermal pulse monitoring of a thermocouple in the measuring channel of a reactor. Measurement method and STDC composition are substantiated. It is shown that introduction of the developed STDC ensures realization of precise and reliable temperature monitoring in the reactors of all types [ru

  7. Introduction: The dialogical self in a global and digital age

    NARCIS (Netherlands)

    Hermans, H.J.M.

    2004-01-01

    In this article, culture and self, like society and identity, are conceived as mutually inclusive. On the basis of this premise, self and identity are discussed in the context of an evolution toward a global and digital society. The core concept is the “dialogical self ”that is described as a

  8. Digital control system of advanced reactor

    International Nuclear Information System (INIS)

    Peng Huaqing; Zhang Rui; Liu Lixin

    2001-01-01

    This article produced the Digital Control System For Advanced Reactor made by NPIC. This system uses Siemens SIMATIC PCS 7 process control system and includes five control system: reactor power control system, pressurizer level control system, pressurizer pressure control system, steam generator water level control system and dump control system. This system uses three automatic station to realize the function of five control system. Because the safety requisition of reactor is very strict, the system is redundant. The system configuration uses CFC and SCL. the human-machine interface is configured by Wincc. Finally the system passed the test of simulation by using RETRAN 02 to simulate the control object. The research solved the key technology of digital control system of reactor and will be very helpful for the nationalization of digital reactor control system

  9. Implementation of TMA and digitalization in routine diagnostics of breast pathology.

    Science.gov (United States)

    Rossing, Henrik Holm; Talman, Maj-Lis Møller; Laenkholm, Anne-Vibeke; Wielenga, Vera Timmermans

    2012-04-01

    To ensure optimal treatment of breast cancer patients, breast tumours are classified based on clinico-pathological features. As part of this process, routine diagnostics of breast tumours includes histological typing and grading, as well as profiling by use of an immunohistochemistry panel of antibodies, probes and in situ hybridization. This will, as a minimum, include assessment of oestrogen receptor (OR) and HER2. The individual preparation and staining of many breast tumours in a large laboratory with this standard panel is thus time consuming and costly. Herein, we show that in breast cancer routine diagnostics the use of the tissue microarray technique in combination with digitalization of the stained multi-slides is not only economical, with a considerable cost reduction, but it also enhances standardization of tumour profiling. We demonstrate that 2 mm breast tumour cores correlate with the corresponding tumour on whole mount slides, regarding staining/hybridizing results with the biomarkers in our panel consisting of human epidermal growth factor receptor 2, OR and Topiomerase IIa. Furthermore, we show that simultaneous staining/hybridizing of multiple breast tumour specimens reduces variation of staining/hybridizing quality, hereby increasing reliability of interpretation. By scanning and digitalization of the stained and hybridized multi-slides, we could optimize documentation and filing of the results. Our work is an example of translational research by implementing a tool in daily diagnostics originally developed for high throughput analyses in the search for prognostic and predictive markers in targeted medicine. © 2012 The Authors APMIS © 2012 APMIS.

  10. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  11. University students’ self-regulated learning using digital technologies

    Directory of Open Access Journals (Sweden)

    Carmen Yot-Domínguez

    2017-11-01

    Full Text Available Abstract Analysing the process by which students—whether at university or not—manage and facilitate their own learning has been a recurrent educational research problem. Recently, the question arises about how the development of strategies taking place during the aforementioned process could be made easier by using technologies. In an effort to know whether university students really use digital technologies to plan, organize and facilitate their own learning, we have proposed three research questions. Which technologies do university students use to self-regulate their learning? What self-regulated learning strategies do they develop using technologies? What profiles could be identified among students based on their use of self-regulation strategies with technology? To answer these questions, the “Survey of Self-regulated Learning with Technology at the University” was designed. Information from a sample group with 711 students from various universities located in the region of Andalusia (Spain was collected with this survey. The results indicate that university students, even when they are frequent users of digital technology, they tend not to use these technologies to regulate their own learning process. Of all technologies analysed, Internet information search and instant communication tools are used continually. In turn, the most generalised self-regulation learning strategies are those relative to social support. Nevertheless, students differ from each other regarding their use and frequency. There are groups of students who make use of self-regulation strategies when learning with technologies. In this regard, two distinctive groups of students have been identified, who show differentiated self-regulated levels.

  12. Interformat reliability of digital psychiatric self-report questionnaires: a systematic review.

    Science.gov (United States)

    Alfonsson, Sven; Maathz, Pernilla; Hursti, Timo

    2014-12-03

    Research on Internet-based interventions typically use digital versions of pen and paper self-report symptom scales. However, adaptation into the digital format could affect the psychometric properties of established self-report scales. Several studies have investigated differences between digital and pen and paper versions of instruments, but no systematic review of the results has yet been done. This review aims to assess the interformat reliability of self-report symptom scales used in digital or online psychotherapy research. Three databases (MEDLINE, Embase, and PsycINFO) were systematically reviewed for studies investigating the reliability between digital and pen and paper versions of psychiatric symptom scales. From a total of 1504 publications, 33 were included in the review, and interformat reliability of 40 different symptom scales was assessed. Significant differences in mean total scores between formats were found in 10 of 62 analyses. These differences were found in just a few studies, which indicates that the results were due to study effects and sample effects rather than unreliable instruments. The interformat reliability ranged from r=.35 to r=.99; however, the majority of instruments showed a strong correlation between format scores. The quality of the included studies varied, and several studies had insufficient power to detect small differences between formats. When digital versions of self-report symptom scales are compared to pen and paper versions, most scales show high interformat reliability. This supports the reliability of results obtained in psychotherapy research on the Internet and the comparability of the results to traditional psychotherapy research. There are, however, some instruments that consistently show low interformat reliability, suggesting that these conclusions cannot be generalized to all questionnaires. Most studies had at least some methodological issues with insufficient statistical power being the most common issue

  13. Improvement of the bandwidth of the transient digitizers in the LIDAR Thomson scattering diagnostic on JET

    International Nuclear Information System (INIS)

    Kristensen, E.

    1990-06-01

    The main limitation on the spatial resolution of the LIDAR Thomson scattering diagnostic on the JET tokamak is due to the narrow bandwidth of the detection system. The transient digitizers, Tektronik 7912AD, are the main contributors to the narrow bandwidth. It is shown how the digitizers can be modified to improve the response time from approx. 480 to 410 ps. (author)

  14. Digital signal processing in power electronics control circuits

    CERN Document Server

    Sozanski, Krzysztof

    2013-01-01

    Many digital control circuits in current literature are described using analog transmittance. This may not always be acceptable, especially if the sampling frequency and power transistor switching frequencies are close to the band of interest. Therefore, a digital circuit is considered as a digital controller rather than an analog circuit. This helps to avoid errors and instability in high frequency components. Digital Signal Processing in Power Electronics Control Circuits covers problems concerning the design and realization of digital control algorithms for power electronics circuits using

  15. On the Control of Self-Balancing Unicycles

    Directory of Open Access Journals (Sweden)

    Felix Freiberger

    2015-11-01

    Full Text Available This paper discusses the problem of designing a self-balancing unicycle where pedals are used for both power generation and speed control. After developing the principal physical aspects (in the longitudinal dimension, we describe an abstract model in the form of a collection of hybrid automata, together with design requirements to be met by an ideal controller. We discuss simplifications and assumptions that make this model amenable to verification and validation tools such as SpaceEx. To enable experimentation with different prototypical controllers and user behaviours in concrete scenarios, we also develop a simple simulation framework using digital time.

  16. Low cost highly available digital control computer

    International Nuclear Information System (INIS)

    Silvers, M.W.

    1986-01-01

    When designing digital controllers for critical plant control it is important to provide several features. Among these are reliability, availability, maintainability, environmental protection, and low cost. An examination of several applications has lead to a design that can be produced for approximately $20,000 (1000 control points). This design is compatible with modern concepts in distributed and hierarchical control. The canonical controller element is a dual-redundant self-checking computer that communicates with a cross-strapped, electrically isolated input/output system. The input/output subsystem comprises multiple intelligent input/output cards. These cards accept commands from the primary processor which are validated, executed, and acknowledged. Each card may be hot replaced to facilitate sparing. The implementation of the dual-redundant computer architecture is discussed. Called the FS-86, this computer can be used for a variety of applications. It has most recently found application in the upgrade of San Francisco's Bay Area Rapid Transit (BART) train control currently in progress and has been proposed for feedwater control in a boiling water reactor

  17. Digital imaging in diagnostic radiology

    International Nuclear Information System (INIS)

    Newell, J.D. Jr.; Kelsey, C.A.

    1990-01-01

    This monograph on digital imaging provides a basic overview of this field at the present time. This paper covers clinical application, including subtraction angiography; chest radiology; genitourinary, gastrointestinal, and breast radiology; and teleradiology. The chest section also includes an explanation of multiple beam equalization radiography. The remaining chapters discuss some of the technical aspects of digital radiology. It includes the basic technology of digital radiography, image compression, and reconstruction information on the economics of digital radiography

  18. Robust digital controllers for uncertain chaotic systems: A digital redesign approach

    Energy Technology Data Exchange (ETDEWEB)

    Ababneh, Mohammad [Department of Controls, FMC Kongsberg Subsea, FMC Energy Systems, Houston, TX 77067 (United States); Barajas-Ramirez, Juan-Gonzalo [CICESE, Depto. De Electronica y Telecomunicaciones, Ensenada, BC, 22860 (Mexico); Chen Guanrong [Centre for Chaos Control and Synchronization, Department of Electronic Engineering, City University of Hong Kong (China); Shieh, Leang S. [Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77204-4005 (United States)

    2007-03-15

    In this paper, a new and systematic method for designing robust digital controllers for uncertain nonlinear systems with structured uncertainties is presented. In the proposed method, a controller is designed in terms of the optimal linear model representation of the nominal system around each operating point of the trajectory, while the uncertainties are decomposed such that the uncertain nonlinear system can be rewritten as a set of local linear models with disturbed inputs. Applying conventional robust control techniques, continuous-time robust controllers are first designed to eliminate the effects of the uncertainties on the underlying system. Then, a robust digital controller is obtained as the result of a digital redesign of the designed continuous-time robust controller using the state-matching technique. The effectiveness of the proposed controller design method is illustrated through some numerical examples on complex nonlinear systems--chaotic systems.

  19. Dose and diagnostic image quality in digital tomosynthesis imaging of facial bones in pediatrics

    Science.gov (United States)

    King, J. M.; Hickling, S.; Elbakri, I. A.; Reed, M.; Wrogemann, J.

    2011-03-01

    The purpose of this study was to evaluate the use of digital tomosynthesis (DT) for pediatric facial bone imaging. We compared the eye lens dose and diagnostic image quality of DT facial bone exams relative to digital radiography (DR) and computed tomography (CT), and investigated whether we could modify our current DT imaging protocol to reduce patient dose while maintaining sufficient diagnostic image quality. We measured the dose to the eye lens for all three modalities using high-sensitivity thermoluminescent dosimeters (TLDs) and an anthropomorphic skull phantom. To assess the diagnostic image quality of DT compared to the corresponding DR and CT images, we performed an observer study where the visibility of anatomical structures in the DT phantom images were rated on a four-point scale. We then acquired DT images at lower doses and had radiologists indicate whether the visibility of each structure was adequate for diagnostic purposes. For typical facial bone exams, we measured eye lens doses of 0.1-0.4 mGy for DR, 0.3-3.7 mGy for DT, and 26 mGy for CT. In general, facial bone structures were visualized better with DT then DR, and the majority of structures were visualized well enough to avoid the need for CT. DT imaging provides high quality diagnostic images of the facial bones while delivering significantly lower doses to the lens of the eye compared to CT. In addition, we found that by adjusting the imaging parameters, the DT effective dose can be reduced by up to 50% while maintaining sufficient image quality.

  20. Digital technology use in ELT classrooms and self-directed learning

    OpenAIRE

    Nehir Sert; Ebru Boynueğri

    2016-01-01

    The digital era is a new challenge for teachers. While children get acquainted with digital technology before the age of six, teachers, who have encountered the digital world at a later time in their lives, struggle with it. Self-directed learning, which is crucial for lifelong learning, can be enhanced by the use of technology within and beyond classroom settings. The aim of this study was to examine the difference between the perceptions of students in low- and high-income groups about thei...

  1. REVIEW OF NRC APPROVED DIGITAL CONTROL SYSTEMS ANALYSIS

    International Nuclear Information System (INIS)

    Markman, D.W.

    1999-01-01

    Preliminary design concepts for the proposed Subsurface Repository at Yucca Mountain indicate extensive reliance on modern, computer-based, digital control technologies. The purpose of this analysis is to investigate the degree to which the U. S. Nuclear Regulatory Commission (NRC) has accepted and approved the use of digital control technology for safety-related applications within the nuclear power industry. This analysis reviews cases of existing digitally-based control systems that have been approved by the NRC. These cases can serve as precedence for using similar types of digitally-based control technologies within the Subsurface Repository. While it is anticipated that the Yucca Mountain Project (YMP) will not contain control systems as complex as those required for a nuclear power plant, the review of these existing NRC approved applications will provide the YMP with valuable insight into the NRCs review process and design expectations for safety-related digital control systems. According to the YMP Compliance Program Guidance, portions of various NUREGS, Regulatory Guidelines, and nuclear IEEE standards the nuclear power plant safety related concept would be applied to some of the designs on a case-by-case basis. This analysis will consider key design methods, capabilities, successes, and important limitations or problems of selected control systems that have been approved for use in the Nuclear Power industry. An additional purpose of this analysis is to provide background information in support of further development of design criteria for the YMP. The scope and primary objectives of this analysis are to: (1) Identify and research the extent and precedence of digital control and remotely operated systems approved by the NRC for the nuclear power industry. Help provide a basis for using and relying on digital technologies for nuclear related safety critical applications. (2) Identify the basic control architecture and methods of key digital control

  2. Digital radiology and digitally formatted image management systems

    International Nuclear Information System (INIS)

    Cox, G.G.; Dwyer, S.J. III; Templeton, A.W.

    1987-01-01

    The number of diagnostic examinations performed with digitally formatted imaging equipment is increasing. Digital general-purpose and fluoroscopic radiology systems are being clinically evaluated. Digitizing conventional x-ray films, such as mammograms, frequently improves the diagnostic quality of the images. The digitizing process with laser has also afforded the opportunity to document required spatial resolution for digital imaging and network systems. The use of digitally formatted image instrumentation imposes new requirements on the acquisition, display and manipulation, transmission, hard copy image recording, and archiving of diagnostic data. Networking of digitally formatted image data offers many advantages for managing digital information. This paper identifies and describes digital radiographic systems. Parameters required for designing and implementing a digital image management system are outlined. Spatial and contrast resolution requirements are identified. The key parameters include the amount of image data generated each working day, the retrieval rate of the generated data, the display hardware and software needed for interactive diagnosis display stations, the requirements for analog hard copy generation, and on-line and long-term archiving requirements. These image management systems are often called PACS (Picture Archiving and Communication Systems)

  3. On the simulation of transients and accidents in PWRs with digital instrumentation and control using an LQR digital controller

    International Nuclear Information System (INIS)

    Alvarenga, M.A.B.; Melo, P.F. Frutuoso e; Medeiros, J.A.C.C.; Oliva, J.J. Rivero

    2015-01-01

    New nuclear power plant designs are including integrated I and C digital systems for protection, control, alarming and monitoring. Existing operating nuclear power plants, as is the case of Angra 1 nuclear power plant, have to consider the replacement of their I and C analog systems by digital systems for retrofitting their facilities. However, before replacing the analog control loops by digital ones it is necessary to design and evaluate their performance, which requires modeling of the plant and its control system with extensive simulations under several normal and abnormal operation conditions. This paper discusses the use of a linear quadratic regulator (LQR) digital controller for evaluating the plant stability behavior before the actuation of the reactor protection system. The objective is to evaluate the effect of digital controllers on plant behavior for several transients and accident conditions. For this purpose, a numerical model was developed and implemented as a MatlabTM tool. This paper discusses an adequate framework in order to simulate a set of transients and accidents that constitute the design basis in the final safety analysis report of PWR power plants to evaluate the performance of digital controllers such as LQR regulators.(author)

  4. Anticipatory planning and control of grasp positions and forces for dexterous two-digit manipulation.

    Science.gov (United States)

    Fu, Qiushi; Zhang, Wei; Santello, Marco

    2010-07-07

    Dexterous object manipulation requires anticipatory control of digit positions and forces. Despite extensive studies on sensorimotor learning of digit forces, how humans learn to coordinate digit positions and forces has never been addressed. Furthermore, the functional role of anticipatory modulation of digit placement to object properties remains to be investigated. We addressed these questions by asking human subjects (12 females, 12 males) to grasp and lift an inverted T-shaped object using precision grip at constrained or self-chosen locations. The task requirement was to minimize object roll during lift. When digit position was not constrained, subjects could have implemented many equally valid digit position-force coordination patterns. However, choice of digit placement might also have resulted in large trial-to-trial variability of digit position, hence challenging the extent to which the CNS could have relied on sensorimotor memories for anticipatory control of digit forces. We hypothesized that subjects would modulate digit placement for optimal force distribution and digit forces as a function of variable digit positions. All subjects learned to minimize object roll within the first three trials, and the unconstrained device was associated with significantly smaller grip forces but larger variability of digit positions. Importantly, however, digit load force modulation compensated for position variability, thus ensuring consistent object roll minimization on each trial. This indicates that subjects learned object manipulation by integrating sensorimotor memories with sensory feedback about digit positions. These results are discussed in the context of motor equivalence and sensorimotor integration of grasp kinematics and kinetics.

  5. Lessons learned in digital upgrade projects digital control system implementation at US nuclear power stations

    International Nuclear Information System (INIS)

    Kelley, S.; Bolian, T. W.

    2006-01-01

    AREVA NP has gained significant experience during the past five years in digital upgrades at operating nuclear power stations in the US. Plants are seeking modernization with digital technology to address obsolescence, spare parts availability, vendor support, increasing age-related failures and diminished reliability. New systems offer improved reliability and functionality, and decreased maintenance requirements. Significant lessons learned have been identified relating to the areas of licensing, equipment qualification, software quality assurance and other topics specific to digital controls. Digital control systems have been installed in non safety-related control applications at many utilities within the last 15 years. There have also been a few replacements of small safety-related systems with digital technology. Digital control systems are proving to be reliable, accurate, and easy to maintain. Digital technology is gaining acceptance and momentum with both utilities and regulatory agencies based upon the successes of these installations. Also, new plants are being designed with integrated digital control systems. To support plant life extension and address obsolescence of critical components, utilities are beginning to install digital technology for primary safety-system replacement. AREVA NP analyzed operating experience and lessons learned from its own digital upgrade projects as well as industry-wide experience to identify key issues that should be considered when implementing digital controls in nuclear power stations

  6. Digital capillaroscopy as important tool for early diagnostics of arterial hypertension

    Science.gov (United States)

    Gurfinkel, Yu. I.; Sasonko, M. L.; Priezzhev, A. V.

    2015-03-01

    The study is aimed to determine the digital capillaroscopy possibilities in early diagnostics of an arterial hypertension. A total of 123 adult persons were examined in the study. The first group consisted of 40 patients with prehypertension (BP 130-139/85-89 mm Hg). The second group included 36 patients with 1-2 stage of hypertension (mean systolic BP 152.7±12 mm Hg). Patients in both groups did not receive regular drug therapy. The group of volunteers (n=47) included healthy adults without signs of cardiovascular pathology. The capillary circulation was examined on the nailbed using the optical digital capillaroscope developed by the company "AET", Russia. Diameters of the arterial and venous segments, perivascular zone size, capillary blood velocity, the degree of arterial loops narrowing and the density of the capillary network were estimated. In patients with arterial hypertension and even in patients with prehypertension remodeling and rarefaction of capillaries and the expressed narrowing their arterial loops were manifested. The results of the study revealed the presence of abnormalities of microcirculation parameters in patients of both groups. The capillaries density in both groups of patients was significantly lower than in healthy persons. The significant narrowing of arterial loops was revealed in patients with both arterial hypertension and prehypertension, in comparison with healthy volunteers. Capillary blood velocity did not differ significantly between healthy volunteers group and the group of prehypertensive patients. However in patients with hypertension this parameter was significantly lower in comparison with control group.

  7. Programmable Digital Controller

    Science.gov (United States)

    Wassick, Gregory J.

    2012-01-01

    An existing three-channel analog servo loop controller has been redesigned for piezoelectric-transducer-based (PZT-based) etalon control applications to a digital servo loop controller. This change offers several improvements over the previous analog controller, including software control over proportional-integral-derivative (PID) parameters, inclusion of other data of interest such as temperature and pressure in the control laws, improved ability to compensate for PZT hysteresis and mechanical mount fluctuations, ability to provide pre-programmed scanning and stepping routines, improved user interface, expanded data acquisition, and reduced size, weight, and power.

  8. Personal digital assistants are comparable to traditional diaries for dietary self-monitoring during a weight loss program.

    Science.gov (United States)

    Yon, Bethany A; Johnson, Rachel K; Harvey-Berino, Jean; Gold, Beth Casey; Howard, Alan B

    2007-04-01

    Dietary self-monitoring is considered the core of behavioral weight control programs. As software for personal digital assistants (PDA) has become more available, this study investigated whether the use of a PDA would improve dietary self-monitoring frequency and subsequent weight loss over the use of traditional paper diaries. One-hundred-seventy-six adults (BMI 25-39.9) participated in a 6-month behavioral weight control program. Treatment subjects (n = 61) were provided with a PalmZire 21 with Calorie King's Diet Diary software installed. Their self-monitoring habits and weight loss were compared with the results from a previous program (n = 115) which followed the same protocol using paper diaries for self-monitoring. No significant differences in weight loss or dietary self-monitoring were found. More frequent self-monitoring correlated with weight loss in both groups (pself-monitoring that is fitting to their lifestyle and skills.

  9. Exploring Entertainment Medicine and Professionalization of Self-Care: Interview Study Among Doctors on the Potential Effects of Digital Self-Tracking

    Science.gov (United States)

    2018-01-01

    Background Nowadays, digital self-tracking devices offer a plethora of possibilities to both healthy and chronically ill users who want to closely examine their body. This study suggests that self-tracking in a private setting will lead to shifting understandings in professional care. To provide more insight into these shifts, this paper seeks to lay bare the promises and challenges of self-tracking while staying close to the everyday professional experience of the physician. Objective The aim of this study was to (1) offer an analysis of how medical doctors evaluate self-tracking methods in their practice and (2) explore the anticipated shifts that digital self-care will bring about in relation to our findings and those of other studies. Methods A total of 12 in-depth semistructured interviews with general practitioners (GPs) and cardiologists were conducted in Flanders, Belgium, from November 2015 to November 2016. Thematic analysis was applied to examine the transcripts in an iterative process. Results Four major themes arose in our body of data: (1) the patient as health manager, (2) health obsession and medicalization, (3) information management, and (4) shifting roles of the doctors and impact on the health care organization. Our research findings show a nuanced understanding of the potentials and pitfalls of different forms of self-tracking. The necessity of contextualization of self-tracking data and a professionalization of self-care through digital devices come to the fore as important overarching concepts. Conclusions This interview study with Belgian doctors examines the potentials and challenges of self-monitoring while focusing on the everyday professional experience of the physician. The dialogue between our dataset and the existing literature affords a fine-grained image of digital self-care and its current meaning in a medical-professional landscape. PMID:29330140

  10. Increased Diagnostic Accuracy of Digital vs. Conventional Clock Drawing Test for Discrimination of Patients in the Early Course of Alzheimer’s Disease from Cognitively Healthy Individuals

    OpenAIRE

    Müller, Stephan; Preische, Oliver; Heymann, Petra; Elbing, Ulrich; Laske, Christoph

    2017-01-01

    The conventional Clock Drawing Test (cCDT) is a rapid and inexpensive screening tool for detection of moderate and severe dementia. However, its usage is limited due to poor diagnostic accuracy especially in patients with mild cognitive impairment (MCI). The diagnostic value of a newly developed digital Clock Drawing Test (dCDT) was evaluated and compared with the cCDT in 20 patients with early dementia due to AD (eDAT), 30 patients with amnestic MCI (aMCI) and 20 cognitively healthy controls...

  11. Application of digital control in Japanese PWR Plants

    International Nuclear Information System (INIS)

    Taguchi, S.; Kondo, Y.; Teranishi, S.; Matsumiya, M.; Takashima, M.; Nagai, T.

    1986-01-01

    More reliable and flexible control system to improve the plant availability and operability is constantly demanded. In order to answer the demands, digital control systems are being applied to Japanese PWR plants. Microprocessor-based digital control systems are widely used in other industries and show good performance. The digital control system has been already applied to the chemical and volume control system and the radioactive waste disposal system in the operating plants. These systems have been working as expected and demonstrating good performances. The digital control system for the reactor control system, which is the main control system of the PWR plants, is being developed. The design of the system has been already finished and the verification/validation process is now in progress

  12. Self-Reported Digital Literacy of the Pharmacy Workforce in North East Scotland

    Directory of Open Access Journals (Sweden)

    Katie MacLure

    2015-10-01

    Full Text Available In their day-to-day practice, pharmacists, graduate (pre-registration pharmacists, pharmacy technicians, dispensing assistants and medicines counter assistants use widely available office, retail and management information systems alongside dedicated pharmacy management and electronic health (ehealth applications. The ability of pharmacy staff to use these applications at home and at work, also known as digital literacy or digital competence or e-skills, depends on personal experience and related education and training. The aim of this research was to gain insight into the self-reported digital literacy of the pharmacy workforce in the North East of Scotland. A purposive case sample survey was conducted across NHS Grampian in the NE of Scotland. Data collection was based on five items: sex, age band, role, pharmacy experience plus a final question about self-reported digital literacy. The study was conducted between August 2012 and March 2013 in 17 community and two hospital pharmacies. With few exceptions, pharmacy staff perceived their own digital literacy to be at a basic level. Secondary outcome measures of role, age, gender and work experience were not found to be clear determinants of digital literacy. Pharmacy staff need to be more digitally literate to harness technologies in pharmacy practice more effectively and efficiently.

  13. Implementation of TMA and digitalization in routine diagnostics of breast pathology

    DEFF Research Database (Denmark)

    Rossing, Henrik Holm; Talman, Maj-Lis; Laenkholm, Anne-Vibeke

    2012-01-01

    To ensure optimal treatment of breast cancer patients, breast tumours are classified based on clinico-pathological features. As part of this process, routine diagnostics of breast tumours includes histological typing and grading, as well as profiling by use of an immunohistochemistry panel...... of antibodies, probes and in situ hybridization. This will, as a minimum, include assessment of oestrogen receptor (OR) and HER2. The individual preparation and staining of many breast tumours in a large laboratory with this standard panel is thus time consuming and costly. Herein, we show that in breast cancer...... routine diagnostics the use of the tissue microarray technique in combination with digitalization of the stained multi-slides is not only economical, with a considerable cost reduction, but it also enhances standardization of tumour profiling. We demonstrate that 2 mm breast tumour cores correlate...

  14. Fault tolerant digital control systems for boiling water reactors

    International Nuclear Information System (INIS)

    Chakraborty, S.; Cash, N.R.

    1986-01-01

    In a Boiling Water Reactor nuclear power plant, the power generation control function is divided into several systems, each system controlling only a part of the total plant. Presently, each system is controlled by conventional analog or digital logic circuits with little interaction for coordinated control. The advent of microprocessors has allowed the development of distributed fault-tolerant digital controls. The objective is to replace these conventional controls with fault-tolerant digital controls connected together with digital communication links to form a fully integrated nuclear power plant control system

  15. An Embedded Based Digital Controller for Thermal Process

    Directory of Open Access Journals (Sweden)

    A. Lakshmi Sangeetha

    2008-01-01

    Full Text Available This paper describes a low cost virtual instrumentation (VI system to monitor and control the electrically heated water bath temperature. The PIC16F877 based digital microcontroller is used as thermostat which controls and monitors the temperature. The digital controller also allows the user to modify the sensor (PT100 calibration data values if necessary. The developed programmable on/off control function provides on-line display of measuring temperature, set point as well as the control function output plots through the parallel port. This bus interaction is realized in Visual Basic/Assembly Language and uses a 16 bit, 10 ms sampling analog-to-digital converter (ADS 7805 for monitoring and controlling the parameters of the temperature local digital controller.

  16. Self and other in digital learning spaces

    DEFF Research Database (Denmark)

    Schraube, Ernst

    expanding human activities, they are also powerful socio-political “forms of life” (Langdon Winner) constituting the relationship between self and the other and transforming fundamentally the practices of teaching and learning and the processes of generating knowledge. This paper explores the meaning......The teaching and learning spaces at universities are in transformation. With the incorporation of electronic technologies like ipads, smart boards and electronic platforms like “moodle” new digital spaces are emerging in educational practices. These technological spaces are not only useful tools...... of digital learning spaces at universities focusing on their implications for the learning processes of students. Usually studies of technology and learning identify teaching with learning and conceptualize research from an external, third-person standpoint. Starting with a discussion of the paradoxes...

  17. Digital control programmer for temperature control

    International Nuclear Information System (INIS)

    Rajore, S.B.; Kumar, S.V.

    1993-01-01

    This report describes a PC based digital control programmer for controlling and programming temperature of a high vacuum resistance heating furnace and the software developed to control power using PID algorithm. It also describes the amplifier specially developed to suit the input requirement of the non-standard W5 thermocouple and the software and hardware protections introduced in the system. (author). 5 refs., 8 figs., 1 appendix

  18. Comparison of Diagnostic Accuracy of Breast Masses Using Digitized Images Versus Screen-Film Mammography

    International Nuclear Information System (INIS)

    Zhigang Liang; Xiangying Du; Jiabin Liu; Xinyu Yao; Yanhui Yang; Kuncheng Li

    2008-01-01

    Background: Medical film digitizers play an important transitory role as digital-analogue bridges in radiology. Digitized mammograms require evaluation of performance to assure medical image quality. Purpose: To compare the diagnostic accuracy in the interpretation of breast masses using original screen-film mammograms versus digitized images. Material and Methods: A total of 72 female patients between 55 and 81 years of age suspected of having breast cancer were selected by two non-observing radiologists. Of these, 31 cases were benign lesions and 41 cases were cancer. The mammography films were digitized using a laser film digitizer. Three radiologists, each with more than 10 years of experience in mammography, interpreted the screen-film mammograms and digitized images respectively. The time interval was 4 weeks. A four-point malignancy scale was used, with 1 defined as definitely not malignant, 2 as probably not malignant, 3 as probably malignant, and 4 as definitely malignant. Receiver operating characteristic (Roc) curves, sensitivity, and specificity were compared. Results: The average area-under-the-curve (Az) value of the original screen-film mammograms was 0.921, and the average Az value of the digitized images was 0.859. This difference was not statistically significant (P=0.131). The detection specificity of extremely dense breasts was lower than that for other breast compositions for both digitized images and screen-film mammograms. No statistical significance in sensitivity and specificity was observed between digitized images and mammograms for each breast composition. Original screen-film mammograms were observed to perform better than digitized images. Conclusion: Digitized images with a spatial resolution of 175 μm can be used instead of screen-film mammograms in the diagnosis of breast cancer

  19. Utility of low-order linear nuclear-power-plant models in plant diagnostics and control

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1981-01-01

    A low-order, linear model of a pressurized water reactor (PWR) plant is described and evaluated. The model consists of 23 linear, first-order difference equations and simulates all subsystems of both the primary and secondary sides of the plant. Comparisons between the calculated model response and available test data show the model to be an adequate representation of the actual plant dynamics. Suggested use for the model in an on-line digital plant diagnostics and control system are presented

  20. High Performance Low Cost Digitally Controlled Power Conversion Technology

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes

    2008-01-01

    in order to reduce the power consumption of servers and datacenters. The work presented in this thesis includes digital control methods for switch-mode converters implemented in microcontrollers, digital signal controllers and field programmable gate arrays. Microcontrollers are cheap devices that can...... be used for real-time control of switch-mode converters. Software design in the assembly language of the microcontroller is important because of the limited resources of the microcontroller. Microcontrollers are best suited for power electronics applications with low bandwidth requirements because...... the execution time of the software algorithm that realises the digital control law will constitute a considerable delay in the control loop. Digital signal controllers are powerful devices capable of performing arithmetic functions much faster than a microcontroller can. Digital signal controllers are well...

  1. Development of digital safety system logic and control

    International Nuclear Information System (INIS)

    Nishikawa, H.; Sakamoto, H.

    1995-01-01

    Advanced-BWR (ABWR) uses total digital control and instrumentation (C and I) system. In particular, ABWR adopts a newly developed safety system using advanced digital technology. In the presentation the digital safety system design, manufacturing and factory validation test method are shortly overviewed. The digital safety system consists of micro-processor based digital controllers, data and information transmission by optical fibers and human-machine interface using color flat displays. This new developed safety system meet the nuclear safety requirements such as high reliability, independence of divisions, operability and maintainability. (2 refs., 4 figs., 1 tab.)

  2. Combating stress risks with the job stress self diagnostic method: paper XV World Congress of Sociology 2002

    NARCIS (Netherlands)

    Oeij, P.R.A.

    2002-01-01

    In this paper of the World Congress of Sociology 2002 of ISA (International Sociological Association), the content and uses of the Job Stress Self Diagnostic Method (JSSDM) are described. The JSSDM aim is (a) to diagnose work processes to determine the presence of conditions for control problems and

  3. Spatially and temporally resolved diagnostics of dense sprays using gated, femtosecond, digital holography

    Science.gov (United States)

    Trolinger, James D.; Dioumaev, Andrei K.; Ziaee, Ali; Minniti, Marco; Dunn-Rankin, Derek

    2017-08-01

    This paper describes research that demonstrated gated, femtosecond, digital holography, enabling 3D microscopic viewing inside dense, almost opaque sprays, and providing a new and powerful diagnostics capability for viewing fuel atomization processes never seen before. The method works by exploiting the extremely short coherence and pulse length (approximately 30 micrometers in this implementation) provided by a femtosecond laser combined with digital holography to eliminate multiple and wide angle scattered light from particles surrounding the injection region, which normally obscures the image of interest. Photons that follow a path that differs in length by more than 30 micrometers from a straight path through the field to the sensor do not contribute to the holographic recording of photons that travel in a near straight path (ballistic and "snake" photons). To further enhance the method, off-axis digital holography was incorporated to enhance signal to noise ratio and image processing capability in reconstructed images by separating the conjugate images, which overlap and interfere in conventional in-line holography. This also enables digital holographic interferometry. Fundamental relationships and limitations were also examined. The project is a continuing collaboration between MetroLaser and the University of California, Irvine.

  4. Validity of Subjective Self-Assessment of Digital Competence among Undergraduate Preservice Teachers

    Science.gov (United States)

    Maderick, Joseph Andrew

    2013-01-01

    Technology is now integrated into the Technological Pedagogical Content Knowledge (TPACK) required to be a highly qualified 21st century teacher. Accurate measurement of digital competence has become critical. Self-assessment has been used widely to measure the digital competence of preservice teachers who are expected to integrate technology into…

  5. Digital base-band rf control system for the superconducting Darmstadt electron linear accelerator

    Directory of Open Access Journals (Sweden)

    M. Konrad

    2012-05-01

    Full Text Available The accelerating field in superconducting cavities has to be stabilized in amplitude and phase by a radio-frequency (rf control system. Because of their high loaded quality factor superconducting cavities are very susceptible for microphonics. To meet the increased requirements with respect to accuracy, availability, and diagnostics, the previous analog rf control system of the superconducting Darmstadt electron linear accelerator S-DALINAC has been replaced by a digital rf control system. The new hardware consists of two components: An rf module that converts the signal from the cavity down to the base-band and a field-programmable gate array board including a soft CPU that carries out the signal processing steps of the control algorithm. Different algorithms are used for normal-conducting and superconducting cavities. To improve the availability of the control system, techniques for automatic firmware and software deployment have been implemented. Extensive diagnostic features provide the operator with additional information. The architecture of the rf control system as well as the functionality of its components will be presented along with measurements that characterize the performance of the system, yielding, e.g., an amplitude stabilization down to (ΔA/A_{rms}=7×10^{-5} and a phase stabilization of (Δϕ_{rms}=0.8° for superconducting cavities.

  6. Piezo-sensor self-diagnostics using electrical impedance measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Park, G. H. (Gyu Hae); Farrar, C. R. (Charles R.); Rutherford, A. C. (Amanda C.); Robertson, A. N. (Amy N.)

    2004-01-01

    This paper present the piezoelectric sensor self-diagnostic procedure that performs in-situ monitoring of the operational status of piezoelectric materials (PZT) used for sensors and actuators in structural health monitoring (SHM) applications. The use of active-sensing piezoelectric materials has received considerable attention in the SHM community. A critical aspect of the piezoelectric active-sensing technologies is that usually large numbers of distributed sensors and actuators are needed to perform the required monitoring process. The sensor/actuator self-diagnostic procedure, where the sensors/actuators are confirmed to be functioning properly during operation, is therefore a critical component to successfully complete the SHM process and to minimize the false indication regarding the structural health. The basis of this procedure is to track the changes in the capacitive value of piezoelectric materials resulting from the sensor failure, which is manifested in the imaginary part of the measured electrical admittances. Furthermore, through the analytical and experimental investigation, it is confirmed that the bonding layer between the PZT and a host structure significantly contributes to the measured capacitive values. Therefore, by monitoring the imaginary part of the admittances, one can quantitatively assess the degradation of the mechanical/electrical properties of the PZT and its attachment to a host structure. This paper concludes with an experimental example to demonstrate the feasibility of the proposed sensor-diagnostic procedure.

  7. Non-synchronous control of self-oscillating resonant converters

    Science.gov (United States)

    Glaser, John Stanley; Zane, Regan Andrew

    2002-01-01

    A self-oscillating switching power converter has a controllable reactance including an active device connected to a reactive element, wherein the effective reactance of the reactance and the active device is controlled such that the control waveform for the active device is binary digital and is not synchronized with the switching converter output frequency. The active device is turned completely on and off at a frequency that is substantially greater than the maximum frequency imposed on the output terminals of the active device. The effect is to vary the average resistance across the active device output terminals, and thus the effective output reactance, thereby providing converter output control, while maintaining the response speed of the converter.

  8. Digital control systems. Verteilte Prozessleitsysteme

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    With a distinct description of the systems properties thin regulation shall provide a latter transparency for the use of digital control systems. The application of the new technique shall be facilitated, incitations for the further development shall be given and the compatibility of the systems shall be advanced. Moreover, the regulation can be used as criteria catalogue for the evaluation of digital systems.

  9. An overview of digital radiography

    International Nuclear Information System (INIS)

    Aweligiba, S. A.

    2013-04-01

    The medical application of radiography has gained wider study since diagnostic radiology plays a very important role in modern medicine for fast diagnosis and therapy. Digital radiography is a relatively new technology that promises greater accuracy, lesser dose and better manipulation of patient radiology images in hospitals. In this study, a general discussion on digital radiography has been presented. The presentation focuses on the optimisation of doses to patients in the medical application of digital radiography, quality control and quality assurance. A brief presentation on performance indicators in digital radiography has also been presented. The advantages of digital radiography over the conventional film/screen system have been elaborated and its limitations are also outlined. (author)

  10. Does a pre-treatment diagnostic interview affect the outcome of internet-based self-help for social anxiety disorder? a randomized controlled trial.

    Science.gov (United States)

    Boettcher, Johanna; Berger, Thomas; Renneberg, Babette

    2012-10-01

    Numerous studies suggest that Internet-based self-help treatments are effective in treating anxiety disorders. Trials evaluating such interventions differ in their screening procedures and in the amount of clinician contact in the diagnostic assessment phase. The present study evaluates the impact of a pre-treatment diagnostic interview on the outcome of an Internet-based treatment for Social Anxiety Disorder (SAD). One hundred and nine participants seeking treatment for SAD were randomized to either an interview-group (IG, N = 53) or to a non-interview group (NIG, N = 56). All participants took part in the same 10-week cognitive-behavioural unguided self-help programme. Before receiving access to the programme, participants of the IG underwent a structured diagnostic interview. Participants of the NIG started directly with the programme. Participants in both groups showed significant and substantial improvement on social anxiety measures from pre- to post-assessment (d IG = 1.30-1.63; d NIG = 1.00-1.28) and from pre- to 4-month follow-up assessment (d IG = 1.38-1.87; d NIG = 1.10-1.21). Significant between-groups effects in favour of the IG were found on secondary outcome measures of depression and general distress (d = 0.18-0.42). These findings suggest that Internet-based self-help is effective in treating SAD, whether or not a diagnostic interview is involved. However, the pre-treatment interview seems to facilitate change on secondary outcomes such as depression and general distress.

  11. The Affective Slider: A Digital Self-Assessment Scale for the Measurement of Human Emotions.

    Science.gov (United States)

    Betella, Alberto; Verschure, Paul F M J

    2016-01-01

    Self-assessment methods are broadly employed in emotion research for the collection of subjective affective ratings. The Self-Assessment Manikin (SAM), a pictorial scale developed in the eighties for the measurement of pleasure, arousal, and dominance, is still among the most popular self-reporting tools, despite having been conceived upon design principles which are today obsolete. By leveraging on state-of-the-art user interfaces and metacommunicative pictorial representations, we developed the Affective Slider (AS), a digital self-reporting tool composed of two slider controls for the quick assessment of pleasure and arousal. To empirically validate the AS, we conducted a systematic comparison between AS and SAM in a task involving the emotional assessment of a series of images taken from the International Affective Picture System (IAPS), a database composed of pictures representing a wide range of semantic categories often used as a benchmark in psychological studies. Our results show that the AS is equivalent to SAM in the self-assessment of pleasure and arousal, with two added advantages: the AS does not require written instructions and it can be easily reproduced in latest-generation digital devices, including smartphones and tablets. Moreover, we compared new and normative IAPS ratings and found a general drop in reported arousal of pictorial stimuli. Not only do our results demonstrate that legacy scales for the self-report of affect can be replaced with new measurement tools developed in accordance to modern design principles, but also that standardized sets of stimuli which are widely adopted in research on human emotion are not as effective as they were in the past due to a general desensitization towards highly arousing content.

  12. The Affective Slider: A Digital Self-Assessment Scale for the Measurement of Human Emotions.

    Directory of Open Access Journals (Sweden)

    Alberto Betella

    Full Text Available Self-assessment methods are broadly employed in emotion research for the collection of subjective affective ratings. The Self-Assessment Manikin (SAM, a pictorial scale developed in the eighties for the measurement of pleasure, arousal, and dominance, is still among the most popular self-reporting tools, despite having been conceived upon design principles which are today obsolete. By leveraging on state-of-the-art user interfaces and metacommunicative pictorial representations, we developed the Affective Slider (AS, a digital self-reporting tool composed of two slider controls for the quick assessment of pleasure and arousal. To empirically validate the AS, we conducted a systematic comparison between AS and SAM in a task involving the emotional assessment of a series of images taken from the International Affective Picture System (IAPS, a database composed of pictures representing a wide range of semantic categories often used as a benchmark in psychological studies. Our results show that the AS is equivalent to SAM in the self-assessment of pleasure and arousal, with two added advantages: the AS does not require written instructions and it can be easily reproduced in latest-generation digital devices, including smartphones and tablets. Moreover, we compared new and normative IAPS ratings and found a general drop in reported arousal of pictorial stimuli. Not only do our results demonstrate that legacy scales for the self-report of affect can be replaced with new measurement tools developed in accordance to modern design principles, but also that standardized sets of stimuli which are widely adopted in research on human emotion are not as effective as they were in the past due to a general desensitization towards highly arousing content.

  13. Low trait self-control predicts self-handicapping.

    Science.gov (United States)

    Uysal, Ahmet; Knee, C Raymond

    2012-02-01

    Past research has shown that self-handicapping stems from uncertainty about one's ability and self-presentational concerns. The present studies suggest that low dispositional self-control is also associated with self-handicapping. In 3 studies (N = 289), the association between self-control and self-handicapping was tested. Self-control was operationalized as trait self-control, whereas self-handicapping was operationalized as trait self-handicapping in Study 1 (N = 160), self-reported self-handicapping in Study 2 (N = 74), and behavioral self-handicapping in Study 3 (N = 55). In all 3 studies, hierarchical regression analyses revealed that low self-control predicts self-handicapping, independent of self-esteem, self-doubt, social desirability, and gender. © 2012 The Authors. Journal of Personality © 2012, Wiley Periodicals, Inc.

  14. Digital redesign of anti-wind-up controller for cascaded analog system.

    Science.gov (United States)

    Chen, Y S; Tsai, J S H; Shieh, L S; Moussighi, M M

    2003-01-01

    The cascaded conventional anti-wind-up (CAW) design method for integral controller is discussed. Then, the prediction-based digital redesign methodology is utilized to find the new pulse amplitude modulated (PAM) digital controller for effective digital control of the analog plant with input saturation constraint. The desired digital controller is determined from existing or pre-designed CAW analog controller. The proposed method provides a novel methodology for indirect digital design of a continuous-time unity output-feedback system with a cascaded analog controller as in the case of PID controllers for industrial control processes with the presence of actuator saturations. It enables us to implement an existing or pre-designed cascaded CAW analog controller via a digital controller effectively.

  15. The Role of Digital 3D Scanned Models in Dental Students' Self-Assessments in Preclinical Operative Dentistry.

    Science.gov (United States)

    Lee, Cliff; Kobayashi, Hiro; Lee, Samuel R; Ohyama, Hiroe

    2018-04-01

    The aim of this study was to determine how dental student self-assessment and faculty assessment of operative preparations compared for conventional visual assessment versus assessment of scanned digital 3D models. In 2016, all third-year students in the Class of 2018 (N=35) at Harvard School of Dental Medicine performed preclinical exams of Class II amalgam preparations (C2AP) and Class III composite preparations (C3CP) and completed self-assessment forms; in 2017, all third-year students in the Class of 2019 (N=34) performed the same exams. Afterwards, the prepared typodont teeth were digitally scanned. Students self-assessed their preparations digitally, and four faculty members graded the preparations conventionally and digitally. The results showed that, overall, the students assessed their preparations higher than the faculty assessments. The mean student-faculty gaps for C2AP and C3CP in the conventional assessments were 11% and 5%, respectively. The mean digital student-faculty gap for C2AP and C3CP were 8% and 2%, respectively. In the conventional assessments, preclinical performance was negatively correlated with the student-faculty gap (r=-0.47, pStudents in the bottom quartile significantly improved their self-assessment accuracy using digital self-assessments over conventional assessments (C2AP 10% vs. 17% and C3CP 3% vs. 10%, respectively). These results suggest that digital assessments offered a significant learning opportunity for students to critically self-assess themselves in operative preclinical dentistry. The lower performing students benefitted the most, improving their assessment ability to the level of the rest of the class.

  16. Illusion Master: Extending Self-Presence and Challenging Immersion in and through Digital Games

    Directory of Open Access Journals (Sweden)

    Josef Florian Micallef

    2016-11-01

    Full Text Available This paper provides an extension of the definition of the concept of self-presence (named Objective self-presence in digital games, and in doing so, challenges the traditional concepts of immersion and presence / self-presence in games. The design process of the submitted game Illusion Master is used as a case study to show how the related concepts of presence and immersion can be addressed in a different manner in and through digital games. It is argued that self-presence need not necessarily involve a situation where players feel as if their virtual self is their actual self. In games studies, this definition of presence is very much linked to the concept of immersion, which looks at how a player is surrounded by an immersive new reality. In this paper, it is argued that self-presence can also manifest itself through a double-consciousness where a player is both engrossed in the game, while remaining conscious of him/herself as a human being engaging with a game outside the game world.

  17. Digitized mammograms

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Balu-Maestro, C.; Rogopoulos, A.; Chauvel, C.; Geoffray, A.

    1988-01-01

    Two observers conducted a blind evaluation of 100 mammography files, including 47 malignant cases. Films were read both before and after image digitization at 50 μm and 100 μm with the FilmDRSII. Digitization permitted better analysis of the normal anatomic structures and moderately improved diagnostic sensitivity. Searches for microcalcifications before and after digitization at 100 μm and 50 μm showed better analysis of anatomic structures after digitization (especially for solitary microcalcifications). The diagnostic benefit, with discovery of clustered microcalcifications, was more limited (one case at 100 μm, nine cases at 50 μm). Recognition of microcalcifications was clearly improved in dense breasts, which can benefit from reinterpretation after digitization at 50 μm rather 100μm

  18. Implementation of Adaptive Digital Controllers on Programmable Logic Devices

    Science.gov (United States)

    Gwaltney, David A.; King, Kenneth D.; Smith, Keary J.; Monenegro, Justino (Technical Monitor)

    2002-01-01

    Much has been made of the capabilities of FPGA's (Field Programmable Gate Arrays) in the hardware implementation of fast digital signal processing. Such capability also makes an FPGA a suitable platform for the digital implementation of closed loop controllers. Other researchers have implemented a variety of closed-loop digital controllers on FPGA's. Some of these controllers include the widely used proportional-integral-derivative (PID) controller, state space controllers, neural network and fuzzy logic based controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM-based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance requirements in a compact form-factor. Generally, a software implementation on a DSP (Digital Signal Processor) or microcontroller is used to implement digital controllers. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using digital signal processor (DSP) devices. While small form factor, commercial DSP devices are now available with event capture, data conversion, pulse width modulated (PWM) outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. In general, very few DSP devices are produced that are designed to meet any level of radiation tolerance or hardness. The goal of this effort is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive control algorithm approaches. An alternative is required for compact implementation of such functionality to withstand the harsh environment

  19. Mathematical (diagnostic algorithms in the digitization of oral histopathology: The new frontier in histopathological diagnosis

    Directory of Open Access Journals (Sweden)

    Abhishek Banerjee

    2015-01-01

    Full Text Available The technological progress in the digitalization of a complete histological glass slide has opened a new door in the tissue based diagnosis. Automated slide diagnosis can be made possible by the use of mathematical algorithms which are formulated by binary codes or values. These algorithms (diagnostic algorithms include both object based (object features, structures and pixel based (texture measures. The intra- and inter-observer errors inherent in the visual diagnosis of a histopathological slide are largely replaced by the use of diagnostic algorithms leading to a standardized and reproducible diagnosis. The present paper reviews the advances in digital histopathology especially related to the use of mathematical algorithms (diagnostic algorithms in the field of oral histopathology. The literature was reviewed for data relating to the use of algorithms utilized in the construction of computational software with special applications in oral histopathological diagnosis. The data were analyzed, and the types and end targets of the algorithms were tabulated. The advantages, specificities and reproducibility of the software, its shortcomings and its comparison with traditional methods of histopathological diagnosis were evaluated. Algorithms help in automated slide diagnosis by creating software with possible reduced errors and bias with a high degree of specificity, sensitivity, and reproducibility. Akin to the identification of thumbprints and faces, software for histopathological diagnosis will in the near future be an important part of the histopathological diagnosis.

  20. Investigation of possible methods for equipment self-tests in digital radiology

    International Nuclear Information System (INIS)

    Zoetelief, J.; Idris, H. H. E.; Jansen, J. T. M.

    2005-01-01

    Quality control in digital radiology can be time-consuming. Equipment self-tests may significantly decrease staff workload. The two most essential parameters for radiology systems are image quality and patient dose. Concerning patient dose, information on the dose-area product (DAP) values generally forms the basis for assessment of patient dose. DAP-values can be measured using a transmission ionisation chamber or calculated from equipment settings. In the present study, various image quality parameters were derived using a contrast-detail (C-D) phantom. The investigation included a computer-aided assessment of C-D images, which produced various parameters, and also parameters based upon scoring by human observers. In addition, another parameter was calculated from modulation transfer function (MTF) measurements. The automatically calculated parameters showed good correlation with human readings, although the number of X-ray systems studied is still limited. We propose a combined evaluation of DAP and automatically calculated C-D or MTF parameters for equipment self-tests. (authors)

  1. Digital Controller For Acoustic Levitation

    Science.gov (United States)

    Tarver, D. Kent

    1989-01-01

    Acoustic driver digitally controls sound fields along three axes. Allows computerized acoustic levitation and manipulation of small objects for such purposes as containerless processing and nuclear-fusion power experiments. Also used for controlling motion of vibration-testing tables in three dimensions.

  2. Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss

    Science.gov (United States)

    Takeshita, Wilton Mitsunari; Vessoni Iwaki, Lilian Cristina; Da Silva, Mariliani Chicarelli; Tonin, Renata Hernandes

    2014-01-01

    Background: To evaluate the diagnostic accuracy of different radiographic methods in the assessment of proximal alveolar bone loss (ABL). Materials and Methods: ABL, the distance between cement-enamel junction and alveolar bone crest, was measured in 70 mandibular human teeth – directly on the mandibles (control), using conventional periapical radiography with film holders (Rinn XCP and Han-Shin), digital periapical radiography with complementary metal-oxide semiconductor sensor, conventional panoramic, and cone-beam computed tomography (CBCT). Three programs were used to measure ABL on the images: Image tool 3.0 (University of Texas Health Sciences Center, San Antonio, Texas, USA), Kodak Imaging 6.1 (Kodak Dental Imaging 6.1, Carestream Health®, Rochester, NY, USA), and i-CAT vision 1.6.20. Statistical analysis used ANOVA and Tukey's test at 5% significance level. Results: The tomographic images showed the highest means, whereas the lowest were found for periapical with Han-Shin. Controls differed from periapical with Han-Shin (P digital periapical (P = 0.0027). Conventional periapicals with film holders differed from each other (P = 0.0007). Digital periapical differed from conventional periapical with Han-Shin (P = 0.0004). Conclusions: Conventional periapical with Han-Shin film holder was the only method that differed from the controls. CBCT had the closest means to the controls. PMID:25191066

  3. Aircraft digital flight control technical review

    Science.gov (United States)

    Davenport, Otha B.; Leggett, David B.

    1993-01-01

    The Aircraft Digital Flight Control Technical Review was initiated by two pilot induced oscillation (PIO) incidents in the spring and summer of 1992. Maj. Gen. Franklin (PEO) wondered why the Air Force development process for digital flight control systems was not preventing PIO problems. Consequently, a technical review team was formed to examine the development process and determine why PIO problems continued to occur. The team was also to identify the 'best practices' used in the various programs. The charter of the team was to focus on the PIO problem, assess the current development process, and document the 'best practices.' The team reviewed all major USAF aircraft programs with digital flight controls, specifically, the F-15E, F-16C/D, F-22, F-111, C-17, and B-2. The team interviewed contractor, System Program Office (SPO), and Combined Test Force (CTF) personnel on these programs. The team also went to NAS Patuxent River to interview USN personnel about the F/A-18 program. The team also reviewed experimental USAF and NASA systems with digital flight control systems: X-29, X-31, F-15 STOL and Maneuver Technology Demonstrator (SMTD), and the Variable In-Flight Stability Test Aircraft (VISTA). The team also discussed the problem with other experts in the field including Ralph Smith and personnel from Calspan. The major conclusions and recommendations from the review are presented.

  4. Control and acquisition for MAST Thomson scattering diagnostics

    International Nuclear Information System (INIS)

    Shibaev, S.; Naylor, G.; Scannell, R.; McArdle, G.; O'Gorman, T.; Walsh, M.J.

    2010-01-01

    The MAST (mega-amp spherical tokamak) Thomson scattering (TS) diagnostics have been radically upgraded and expanded. Eight 30 Hz 1.6 J Nd:YAG lasers have been combined to produce a sampling rate of 240 Hz. The scattered signals are acquired by two spectrometer systems: core and edge. The core system has been built anew: collection optics, polychromators, digitizers, and control computers. It allows measurement of electron temperature and density at 130 spatial points with ∼10 mm resolution across the plasma. The Nd:YAG scattered light signals are registered in 650 channels as polychromator outputs; each channel is registered on two ADCs: at 1 GHz rate in a short interval around each laser pulse and at 100 kHz for background data. The fast ADCs are combined in 26 data acquisition units. Each unit is assembled in a 6 U PXI chassis with embedded controller and six 4-channel 1 GHz ADC cards. Some chassis contain a 96-channel slow ADC card with Ethernet control. The Ruby TS has been rebuilt with a new spectrometer and CCD camera to provide higher spatial resolution - 512 points; the laser has been modified to add double pulse capability. A new control and acquisition system has been developed; it has modular design allowing flexibility and seamless expansion. The system supports event-triggered and real-time operation (will be added in a later stage). A smart trigger device has been developed for TS timing and synchronisation. It provides complex pulse sequences for laser firing with resynchronisation on a number of digital and analogue inputs including plasma events. This device also triggers TS acquisition. The system is integrated by a TS master process running on the dedicated computer; it is represented as a standard MAST data acquisition unit. The Ruby TS is also implemented as a standard MAST unit linked with the Nd:YAG TS by MAST system services.

  5. 47 CFR 73.9001 - Redistribution control of digital television broadcasts.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Redistribution control of digital television... RADIO SERVICES RADIO BROADCAST SERVICES Digital Broadcast Television Redistribution Control § 73.9001 Redistribution control of digital television broadcasts. Licensees of TV broadcast stations may utilize the...

  6. A digital joint controller for manipulators

    International Nuclear Information System (INIS)

    Holt, E.J.; Palmer, D.E.B.

    1993-01-01

    Nuclear Electric's hydraulic heavy duty manipulators are used at a number of Magnox Power Stations for a wide variety of tasks. In recent years there has been a trend towards the use of manipulators for tasks requiring increasing precision of tip positioning. In order to meet this requirement, a digital controller has been designed to replace the analogue controller board used in almost all manipulator control systems. The new controller allows the programming of a wide range of closed loop control algorithms. Position and drive signal data may be passed to and from the controller by digital means, allowing direct connection to a graphical display system and/or a computer executing a guidance algorithm. The hardware and software design are outlined and performance in the laboratory and the field is reported. (author)

  7. Hardware replacements and software tools for digital control computers

    International Nuclear Information System (INIS)

    Walker, R.A.P.; Wang, B-C.; Fung, J.

    1996-01-01

    Technological obsolescence is an on-going challenge for all computer use. By design, and to some extent good fortune, AECL has had a good track record with respect to the march of obsolescence in CANDU digital control computer technology. Recognizing obsolescence as a fact of life, AECL has undertaken a program of supporting the digital control technology of existing CANDU plants. Other AECL groups are developing complete replacement systems for the digital control computers, and more advanced systems for the digital control computers of the future CANDU reactors. This paper presents the results of the efforts of AECL's DCC service support group to replace obsolete digital control computer and related components and to provide friendlier software technology related to the maintenance and use of digital control computers in CANDU. These efforts are expected to extend the current lifespan of existing digital control computers through their mandated life. This group applied two simple rules; the product, whether new or replacement should have a generic basis, and the products should be applicable to both existing CANDU plants and to 'repeat' plant designs built using current design guidelines. While some exceptions do apply, the rules have been met. The generic requirement dictates that the product should not be dependent on any brand technology, and should back-fit to and interface with any such technology which remains in the control design. The application requirement dictates that the product should have universal use and be user friendly to the greatest extent possible. Furthermore, both requirements were designed to anticipate user involvement, modifications and alternate user defined applications. The replacements for hardware components such as paper tape reader/punch, moving arm disk, contact scanner and Ramtek are discussed. The development of these hardware replacements coincide with the development of a gateway system for selected CANDU digital control

  8. Does Self-Control Training Improve Self-Control? A Meta-Analysis.

    Science.gov (United States)

    Friese, Malte; Frankenbach, Julius; Job, Veronika; Loschelder, David D

    2017-11-01

    Self-control is positively associated with a host of beneficial outcomes. Therefore, psychological interventions that reliably improve self-control are of great societal value. A prominent idea suggests that training self-control by repeatedly overriding dominant responses should lead to broad improvements in self-control over time. Here, we conducted a random-effects meta-analysis based on robust variance estimation of the published and unpublished literature on self-control training effects. Results based on 33 studies and 158 effect sizes revealed a small-to-medium effect of g = 0.30, confidence interval (CI 95 ) [0.17, 0.42]. Moderator analyses found that training effects tended to be larger for (a) self-control stamina rather than strength, (b) studies with inactive compared to active control groups, (c) males than females, and (d) when proponents of the strength model of self-control were (co)authors of a study. Bias-correction techniques suggested the presence of small-study effects and/or publication bias and arrived at smaller effect size estimates (range: g corrected = .13 to .24). The mechanisms underlying the effect are poorly understood. There is not enough evidence to conclude that the repeated control of dominant responses is the critical element driving training effects.

  9. DEMO diagnostics and burn control

    Energy Technology Data Exchange (ETDEWEB)

    Biel, Wolfgang, E-mail: w.biel@fz-juelich.de [Institute of Energy and Climate Research, Forschungszentrum Jülich GmbH, Jülich (Germany); Department of Applied Physics, Ghent University (Belgium); Baar, Marco de [FOM-Institute DIFFER, Nieuwegein (Netherlands); Eindhoven University of Technology (Netherlands); Dinklage, Andreas [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Felici, Federico [Eindhoven University of Technology (Netherlands); König, Ralf [Max-Planck-Institut für Plasmaphysik, Greifswald (Germany); Meister, Hans; Treutterer, Wolfgang [Max-Planck-Institut für Plasmaphysik, Garching (Germany); Wenninger, Ronald [Max-Planck-Institut für Plasmaphysik, Garching (Germany); EFDA Power Plant Physics and Technology, Garching (Germany)

    2015-10-15

    Highlights: • An initial concept for the DEMO diagnostic and control system is presented. • A preliminary list of control functions and candidate diagnostics is developed. • Challenges regarding disruptions, power exhaust and radiation control are highlighted. • The need for introducing realistic control margins is emphasized. • On outline of the future R&D plan is presented. - Abstract: The development of the control system for a tokamak demonstration fusion reactor (DEMO) faces unprecedented challenges. First, the requirements for control reliability and accuracy are more stringent than on existing fusion devices: any loss of plasma control on DEMO may result in a disruption which could damage the inner wall of the machine, while operating the device with larger margins against the operational limits would lead to a reduction of the electrical output power. Second, the performance of DEMO control is limited by space restrictions for the implementation of components (optimization of the tritium breeding rate), by lifetime issues for the front-end parts (neutron and gamma radiation, erosion and deposition acting on all components) and by slow, weak and indirect action of the available actuators (plasma shaping, heating and fuelling). The European DEMO conceptual design studies include the development of a reliable control system, since the details of the achievable plasma scenario and the machine design may depend on the actual performance of the control system. In the first phase of development, an initial understanding of the prime choices of diagnostic methods applicable to DEMO, implementation and performance issues, the interrelation with the plasma scenario definition, and the planning of necessary future R&D have been obtained.

  10. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    Science.gov (United States)

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  12. Diagnostic capability of 100-mm roll film digitizer system

    International Nuclear Information System (INIS)

    Kono, M.; Yamasaki, K.; Ikeda, M.

    1988-01-01

    The authors recently developed a roll film digitizer system. The sampling pitch is 100 μm. a scientific image study (Barger phantom, Hawlet chart, and modulation transfer function), receiver operating characteristic (ROC) study, and clinical evaluation were performed. For the ROC study, a chest phantom with simulated nodule and hairline was used. Differences in accuracy between readings of cathode ray tube (CRT) images and roll film images were not statistically significant for hairline and coin lesions, P<.05). As a clinical evaluation, eight radiologists evaluated predetermined radiologic findings on a five-point rating scale compared with original roll film images. Scores for CRT images were equal to those for the original roll film images. In conclusion, CRT images (1,000 x 1,000) were found to be sufficient for diagnostic accuracy of chest images compared with roll film images (100 x 100 mm)

  13. Digital electro-hydraulic control system for nuclear turbine

    International Nuclear Information System (INIS)

    Yokota, Yutaka; Tone, Youichi; Ozono, Jiro

    1985-01-01

    The unit capacity of steam turbines for nuclear power generation is very large, accordingly their unexpected stop disturbs power system, and the lowering of their capacity ratio exerts large influence on power generation cost. Therefore, very high reliability is required for turbine EHC controllers which directly control the turbines for nuclear power generation. In order to meet such requirement, Toshiba Corp. has developed high reliability type analog tripled turbine EHC controllers, and delivered them to No. 3 plant in the Fukushima No. 2 Nuclear Power Station and No. 1 plant in the Kashiwazaki Kariwa Nuclear Power Station, Tokyo Electric Power Co., Inc. At present, the trial operation is under way. The development of digital EHC controllers was begun in 1976, and through the digital EHC for a test turbine and that for a small turbine, the digital EHC controllers for the turbines for nuclear power generation were developed. In this paper, the function, constitution, features and maintenance of the digital tripled EHC controllers for the turbines for nuclear power generation, the application of new technology to them, and the confirmation of the control function by simulation are reported. (Kako, I.)

  14. Digital Sliding Mode Control of Anti-Lock Braking System

    Directory of Open Access Journals (Sweden)

    MITIC, D. B.

    2013-02-01

    Full Text Available The control of anti-lock braking system is a great challenge, because of the nonlinear and complex characteristics of braking dynamics, unknown parameters of vehicle environment and system parameter variations. Using some of robust control methods, such as sliding mode control, can be a right solution for these problems. In this paper, we introduce a novel approach to design of ABS controllers, which is based on digital sliding mode control with only input/output measurements. The relay term of the proposed digital sliding mode control is filtered through digital integrator, reducing the chattering phenomenon in that way, and the additional signal of estimated modelling error is introduced into control algorithm to enhance the system steady-state accuracy. The given solution was verified in real experimental framework and the obtained results were compared with the results of implementation of two other digital sliding mode control algorithms. It is shown that it gives better system response, higher steady-state accuracy and smaller chattering.

  15. Using the digital reactor control systems at NPP

    International Nuclear Information System (INIS)

    Schirl, G.; Hertel, J.

    2006-01-01

    A conception of application of the digital reactor control systems (RCS) at NPP is presented. The digital RCS architecture and safety ensuring are considered. The strategy and algorithm of the operating NPP equipping with the new digital RCS are given too [ru

  16. Swedish primary healthcare nurses' perceptions of using digital eHealth services in support of patient self-management.

    Science.gov (United States)

    Öberg, Ulrika; Orre, Carl Johan; Isaksson, Ulf; Schimmer, Robyn; Larsson, Håkan; Hörnsten, Åsa

    2017-09-28

    Nurses have expressed doubts about the ongoing digitalisation of Swedish primary health care. Given the potential role of eHealth in primary health care, including supporting interactive self-management for people with chronic conditions, it is important to highlight nurses' experiences. This study is part of a larger project aimed at implementing person-centred interactive self-management support (iSMS) in primary health care. The aim of this study was to describe Swedish primary healthcare nurses' perceptions of using digital eHealth systems and services to support patient self-management. Focus group interviews were conducted with primary healthcare nurses (n = 20). The interview transcriptions were analysed using qualitative content analysis. Three themes emerged from the content analysis: caregiving in the midst of digital chaos; a lack of overview and control in daily work; and mixed feelings towards digitalisation. Each theme was subdivided into three subthemes. The results of this study provide insight into a number of concerns that stand in the way of success when it comes to the implementation and use of digital technology. If nurses are to adapt to the new policies and practices that accompany the current digitalised development in Swedish primary health care, the concept of a nurse's traditional work role needs to be amended in terms of the scope of work tasks and established views of traditional nursing. The study also highlights the need for more research to enable eHealth systems/services to be designed to fulfil multiple requirements. The digitised systems should be a tool for achieving good quality self-management support as well as giving the primary healthcare nurses adequate resources to support patients' self-management while still maintaining the values associated with person-centred care. © 2017 Nordic College of Caring Science.

  17. Diagnostic imaging costs before and after digital tomosynthesis implementation in patient management after detection of suspected thoracic lesions on chest radiography.

    Science.gov (United States)

    Quaia, Emilio; Grisi, Guido; Baratella, Elisa; Cuttin, Roberto; Poillucci, Gabriele; Kus, Sara; Cova, Maria Assunta

    2014-02-01

    To evaluate diagnostic imaging costs before and after DTS implementation in patients with suspected thoracic lesions on CXR. Four hundred sixty-five patients (263 male, 202 female; age, 72.47 ± 11.33 years) with suspected thoracic lesion(s) after CXR underwent DTS. Each patient underwent CT when a pulmonary non-calcified lesion was identified by DTS while CT was not performed when a benign pulmonary or extrapulmonary lesion or pseudolesion was identified. The average per-patient imaging cost was calculated by normalising the costs before and after DTS implementation. In 229/465 patients who underwent DTS after suspicious CXR, DTS showed 193 pulmonary lesions and 36 pleural lesions, while in the remaining 236/465 patients, lesions were ruled out as pseudolesions of CXR. Chest CT examination was performed in 127/465 (27 %) patients while in the remaining 338/465 patients (73 %) CXR doubtful findings were resolved by DTS. The average per-patient costs of CXR, DTS and CT were 15.15, 41.55 and 113.66. DTS allowed an annual cost saving of 8,090.2 considering unenhanced CT and 19,298.12 considering contrast-enhanced CT. Considering a DTS reimbursement rate of 62.7 the break even point corresponds to 479 DTS examinations. Per-patient diagnostic imaging costs decreased after DTS implementation in patients with suspected thoracic lesions. • Digital tomosynthesis improves the diagnostic accuracy and confidence in chest radiography • Digital tomosynthesis reduces the need for CT for a suspected pulmonary lesion • Digital tomosynthesis requires a dose level equivalent to that of around two chest radiographies • Digital tomosynthesis produces a significant per-patient saving in diagnostic imaging costs.

  18. System control module diagnostic Expert Assistant

    Science.gov (United States)

    Flores, Luis M.; Hansen, Roger F.

    1990-01-01

    The Orbiter EXperiments (OEX) Program was established by NASA's Office of Aeronautics and Space Technology (OAST) to accomplish the precise data collection necessary to support a complete and accurate assessment of Space Transportation System (STS) Orbiter performance during all phases of a mission. During a mission, data generated by the various experiments are conveyed to the OEX System Control Module (SCM) which arranges for and monitors storage of the data on the OEX tape recorder. The SCM Diagnostic Expert Assistant (DEA) is an expert system which provides on demand advice to technicians performing repairs of a malfunctioning SCM. The DEA is a self-contained, data-driven knowledge-based system written in the 'C' Language Production System (CLIPS) for a portable micro-computer of the IBM PC/XT class. The DEA reasons about SCM hardware faults at multiple levels; the most detailed layer of encoded knowledge of the SCM is a representation of individual components and layouts of the custom-designed component boards.

  19. Improved safety in advanced control complexes, without side effects

    International Nuclear Information System (INIS)

    Harmon, D.L.

    1997-01-01

    If we only look for a moment at the world around us, it is obvious that advances in digital electronic equipment and Human-System Interface (HSI) technology are occurring at a phenomenal pace. This is evidenced from our home entertainment systems to the dashboard and computer-based operation of our new cars. Though the nuclear industry has less vigorously embraced these advances, their application is being implemented through individual upgrades to current generation nuclear plants and as plant-wide control complexes for advanced plants. In both venues modem technology possesses widely touted advantages for improving plant availability as well as safety. The well-documented safety benefits of digital Instrumentation and Controls (I ampersand C) include higher reliability resulting from redundancy and fault tolerance, inherent self-test and self-diagnostic capabilities which have replaced error-prone human tasks, resistance to setpoint drift increasing available operating margins, and the ability to run complex, real-time, computer-based algorithms directly supporting an operator's monitoring and control task requirements. 22 refs., 3 figs., 5 tabs

  20. Digital Communication System Based on Polarization Self-Modulation in Lasers

    Science.gov (United States)

    Tabarin, V. A.; Ikonnikov, V. P.; Shatalov, A. N.

    2014-09-01

    Polarization self-modulation in lasers can be used to create instruments for generating optical pulses at very high repetition rates without using high-speed electronics. Self-oscillation is observed when part of the output of a laser is returned to the laser after a 90° polarization change. A practical scheme based on polarization self-modulation in a 3.39-μm helium-neon laser is proposed for pulsed code data transmission with an yttrium-iron garnet magnetooptical Q-switch. Highly efficient transmission of digital signals is implemented with a repetition rate of 75 MHz, equivalent to half the free spectral range of the laser.

  1. [The point-digital interpretation and the choice of the dermatoglyphic patterns on human fingers for diagnostics of consanguineous relationship].

    Science.gov (United States)

    Zvyagin, V N; Rakitin, V A; Fomina, E E

    The objective of the present study was the development of the point-digital model for the scaless interpretation of the dermatoglyphic papillary patterns on human fingers that would allow to comprehensively describe, in digital terms, the main characteristics of the traits and perform the quantitative assessment of the frequency of their inheritance. A specially developed computer program, D.glyphic. 7-14 was used to mark the dermatoglyphic patterns on the fingerprints obtained from 30 familial triplets (father + mother + child).The values of all the studied traits for kinship diagnostics were found by calculating the ratios of the sums of differences between the traits in the parent-parent pairs to those in the respective parent-child pairs. The algorithms for the point marking of the traits and reading out the digital information about them have been developed. The traditional dermatoglyphic patterns were selected and the novel ones applied for the use in the framework of the point-digital model for the interpretation of the for diagnostics of consanguineous relationship. The present experimental study has demonstrated the high level of inheritance of the selected traits and the possibility to develop the algorithms and computation techniques for the calculation of consanguineous relationship coefficients based on these traits.

  2. Diagnostic Value of Conventional and Digital Radiography for Detection of Cavitated and Non-Cavitated Proximal Caries

    Directory of Open Access Journals (Sweden)

    Mahdieh Dehghani

    2017-02-01

    Full Text Available Objectives: This study aimed to assess the diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries.Materials and Methods: Fifty extracted human premolars and molars were mounted in a silicone block. Charge-coupled device (CCD and photostimulable phosphor plate (PSP receptors and intra-oral films were exposed with 60 and 70 kVp with parallel technique. Two observers interpreted the radiographs twice with a two-week interval using a 5-point scale. Teeth were then serially sectioned in mesiodistal direction and evaluated under a stereomicroscope (gold standard. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated.Results: Sensitivity of all three receptors for detection of enamel lesions was low (5.5-44.4% but it was higher for dentin lesions (42.8-62.8%; PSP with 70 kVp and 0.03s exposure time had the highest sensitivity for enamel lesions, but the difference among receptors was not statistically significant (P>0.05. Sensitivity of all three receptors for detection of non-cavitated lesions was lower than that for cavitated lesions; PSP with 60 kVp and 0.07s exposure time had higher sensitivity and lower patient radiation dose for detection of cavitated and non-cavitated lesions, but the difference was not significant (P>0.05.Conclusions: Digital radiography using PSP receptor with 70 kVp is recommended to detect initial enamel caries. For detection of non-cavitated and cavitated dentin caries, PSP with 60 kVp is more appropriate. Change in kVp did not affect the diagnostic accuracy for detection of caries, and type of receptor was a more important factor.Keywords: Dental Caries; Diagnostic Imaging; Radiography, Dental, Digital

  3. Digital regulation of a phase controlled power converter

    International Nuclear Information System (INIS)

    Schultheiss, C.; Haque, T.

    1995-01-01

    The Relativistic Heavy Ion Collider, now in construction at Brookhaven National Laboratory, will use phase controlled power converters for the main dipole and quadrupole magnet strings. The rectifiers in these power supplies will be controlled by a digital regulator based on the TI 320C30 Digital Signal Processor (DSP). The DSP implements the current loop, the voltage loop, and a system to actively reduce the sub-harmonic ripple components. Digital firing circuits consisting of a phase locked lop and counters are used to fire the SCRs. Corrections for the sub-harmonic reduction are calculated by the DSP and stored in registers in the firing circuit. These corrections are added in hardware, to the over-all firing count provided by the DSP. the resultant count is compared to a reference counter to fire the SCRs. This combination of a digital control system and the digital firing circuits allows the correction of the sub-harmonics in a real-time sense. A prototype of the regulator has been constructed, and the preliminary testing indicates a sub-harmonic reduction of 60 dB

  4. Marketing to the digital self - assessing the variables affecting the adoption and retention of branded Smartphone applications in relation to the theory of self-concept

    OpenAIRE

    Read, Samantha M

    2016-01-01

    This research explores the extent to which Smartphones and Smartphone apps can be viewed as an extension of ourselves. Digital technology allows us to shape who we are (our actual self) and re-invent who we want to be (our ideal self), yet little research has explored how a consumer’s self-concept effects their brand engagement with Smartphone apps. Drawing on research from Marketing Communications, Psychology and Human-computer interaction, the relationship between consumers’ digital selves ...

  5. Research on digital PID control algorithm for HPCT

    International Nuclear Information System (INIS)

    Zeng Yi; Li Rui; Shen Tianjian; Ke Xinhua

    2009-01-01

    Digital PID applied in high-precision HPCT (High-precision current transducer) based on Digital Signal Processor (DSP) TMS320F2812 and special D/A converter was researched. By using increment style PID Control algorithm, the stability and precision of high-precision HPCT output voltage is improved. On basis of deeply analysing incremental digital PID, the scheme model of HPCT is proposed, the feasibility simulation using Matlab is given. Practical hardware circuit verified the incremental PID has closed-loop control process in tracking HPCT output voltage. (authors)

  6. Computationally efficient methods for digital control

    NARCIS (Netherlands)

    Guerreiro Tome Antunes, D.J.; Hespanha, J.P.; Silvestre, C.J.; Kataria, N.; Brewer, F.

    2008-01-01

    The problem of designing a digital controller is considered with the novelty of explicitly taking into account the computation cost of the controller implementation. A class of controller emulation methods inspired by numerical analysis is proposed. Through various examples it is shown that these

  7. Evidence-Centered Design for Diagnostic Assessment within Digital Learning Environments: Integrating Modern Psychometrics and Educational Data Mining

    Science.gov (United States)

    Rupp, André A.; Nugent, Rebecca; Nelson, Brian

    2012-01-01

    In recent years the educational community has increasingly embraced digital technologies for the purposes of developing alternative learning environments, providing diagnostic feedback, and fostering the development of so-called 21st-century skills. This special issue is dedicated to bridging recent work from the disciplines of educational and…

  8. Digital Signal Processing and Control for the Study of Gene Networks

    Science.gov (United States)

    Shin, Yong-Jun

    2016-04-01

    Thanks to the digital revolution, digital signal processing and control has been widely used in many areas of science and engineering today. It provides practical and powerful tools to model, simulate, analyze, design, measure, and control complex and dynamic systems such as robots and aircrafts. Gene networks are also complex dynamic systems which can be studied via digital signal processing and control. Unlike conventional computational methods, this approach is capable of not only modeling but also controlling gene networks since the experimental environment is mostly digital today. The overall aim of this article is to introduce digital signal processing and control as a useful tool for the study of gene networks.

  9. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry

    Science.gov (United States)

    Serafini, S.; Paone, N.; Castellini, P.

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control.

  10. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry.

    Science.gov (United States)

    Serafini, S; Paone, N; Castellini, P

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control.

  11. Exploring Entertainment Medicine and Professionalization of Self-Care: Interview Study Among Doctors on the Potential Effects of Digital Self-Tracking

    NARCIS (Netherlands)

    Gabriels, K.; Moerenhout, T.

    2018-01-01

    Background: Nowadays, digital self-tracking devices offer a plethora of possibilities to both healthy and chronically ill users who want to closely examine their body. This study suggests that self-tracking in a private setting will lead to shifting understandings in professional care. In order to

  12. The use of a personal digital assistant for dietary self-monitoring does not improve the validity of self-reports of energy intake.

    Science.gov (United States)

    Yon, Bethany Ann; Johnson, Rachel K; Harvey-Berino, Jean; Gold, Beth Casey

    2006-08-01

    Underreporting of energy intake is a pervasive problem and resistant to improvement, especially among people with overweight and obesity. The goal of this study was to investigate whether the use of a personal digital assistant (PDA) for dietary self-monitoring would reduce underreporting prevalence and improve the validity of self-reported energy intake. Adults with overweight and obesity (n=61, 92% women, mean age 48.2 years, mean body mass index 32.3) were provided with a PalmZire 21 (Palm, Inc, Sunnyvale, CA) loaded with Calorie King's Diet Diary software (version 3.2.2, 2002, Family Health Network, Costa Mesa, CA). Subjects participated in a 24-week in-person behavioral weight control program and were asked to self-monitor their diet and exercise habits using the PDA. Basal metabolic rate and physical activity level were estimated at baseline. Energy intake from 7-day electronic food records were collected within the first month of the weight-control program. As subjects were actively losing weight, Bandini's adjustments were used to correct self-reported energy intake for weight loss. In this group, where 41% of the subjects were categorized as low-energy reporters, the use of a PDA did not improve validity of energy reporting when compared to what is reported in the literature.

  13. Real-time measurement and control at JET signal processing and physics analysis for diagnostics

    International Nuclear Information System (INIS)

    Felton, R.; Joffrin, E.; Murari, A.

    2005-01-01

    To meet the requirements of the scientific programme, the EFDA JET real-time measurement and control project has developed an integrated set of real-time plasma measurements, experiment control and communication facilities. Traditional experiments collected instrument data during the plasma pulse and calculated physics data after the pulse. The challenge for continuous tokamak operation is to calculate the physics data in real-time, keeping up with the evolution of the plasma. In JET, many plasma diagnostics have been augmented with extra data acquisition and signal-processing systems so that they can both capture instrument data for conventional post-pulse analysis and calculate calibrated, validated physics results in real-time. During the pulse, the systems send sampled data sets into a network, which distributes the data to several destinations. The receiving systems may do further analysis, integrating data from several measurements, or may control the plasma scenario by heating or fuelling. The simplest real-time diagnostic systems apply scale factors to the signals, as with the electron cyclotron emission (ECE) diagnostic's 96 tuned radiometer channels, giving the electron temperature profile. In various spectroscopy diagnostics, spectral features are least-squares-fitted to measure spectra from several lines of sight, within 50 ms. Ion temperatures and rotation speed can be calculated from the line widths and shifts. For diagnostics using modulation techniques, the systems implement digital-signal processing phase trackers, lock-in amplifiers and filters, e.g., the far infrared (FIR) interferometer samples 15 channels at 400 kHz for 30 s, i.e., six million samples per second. Diagnostics have specific lines of sight, spatial channels, and various sampling rates. The heating/fuelling systems have relatively coarse spatial localisation. Analysis systems have been developed to integrate the basic physics data into smaller sets of controllable parameters on a

  14. Digital technology use in ELT classrooms and self-directed learning

    Directory of Open Access Journals (Sweden)

    Nehir Sert

    2016-04-01

    Full Text Available The digital era is a new challenge for teachers. While children get acquainted with digital technology before the age of six, teachers, who have encountered the digital world at a later time in their lives, struggle with it. Self-directed learning, which is crucial for lifelong learning, can be enhanced by the use of technology within and beyond classroom settings. The aim of this study was to examine the difference between the perceptions of students in low- and high-income groups about their use of technology in a general sense and their teachers’ use of technology in ELT classrooms. It also tested the correlation between the perceptions of their self-directed learning behaviours and their own/their teachers’ technology use. The population of the study consisted of 75 students from high- and 70 students from low-income groups. Causal comparative and correlational research methods were adopted in the study. The surveys to measure the students’ perceptions about technology use were developed by the researchers. A scale, established by Demirtas and Sert (2010, was used to identify the level of self-directed learning views of the students. The data were collected at the beginning of the first term of the 2015-2016 school year. The results indicated that there was no significant difference between perceptions of the low- and high-income students regarding their own technology use. Likewise, perceptions of the low- and high-income students did not differ regarding their teachers’ technology use. There was no correlation between the perceptions of the low-/high-income mixed group regarding their use of technology and their teachers’ use of technology. Lastly, self-directed learning perceptions of the low-/high-income mixed group did not correlate with their perceptions on any aspects of technology use. The educational implications of these results were discussed and suggestions were put forward in order to produce more effective learning

  15. Digital signal processing in power system protection and control

    CERN Document Server

    Rebizant, Waldemar; Wiszniewski, Andrzej

    2011-01-01

    Digital Signal Processing in Power System Protection and Control bridges the gap between the theory of protection and control and the practical applications of protection equipment. Understanding how protection functions is crucial not only for equipment developers and manufacturers, but also for their users who need to install, set and operate the protection devices in an appropriate manner. After introductory chapters related to protection technology and functions, Digital Signal Processing in Power System Protection and Control presents the digital algorithms for signal filtering, followed

  16. Controls and diagnostics on a fuseless railgun for solid hydrogen pellet acceleration

    International Nuclear Information System (INIS)

    King, T.L.; Zhang, J.; Haywood, R.G.; Manns, W.C.; Kim, K.

    1993-01-01

    A two-stage railgun system has been built incorporating several controls and diagnostics, some including unique features to account for the fact that the projectile is a frozen hydrogen pellet for fusion reactor refueling. A timing circuit has been developed to monitor projectile breech and muzzle velocities and to automatically trigger a sequence of events critical for effective plasma armature railgun operation. This circuit can initiate electrical breakdown of the propellant gas directly behind an incoming projectile, thus enabling fuseless operation. It also triggers a streak camera and a flashlamp for photographing the arc and the outgoing projectile, respectively. The automatic timing circuit is expandable and has been extended to incorporate a trigger for transaugmentation. The timing circuit is immune to mistriggering due to electromagnetic interference or fragmentation of the fragile hydrogen pellets. Railgun diagnostics also include Pearson coils and B probes for monitoring rail and armature currents, respectively. Laser interferometry and optical spectroscopy are also employed to measure plasma density and temperature. Digitizing oscilloscopes are used to acquire data. The data is transferred to a computer via GPIB

  17. Digital control for the Penn State Breazeale reactor

    International Nuclear Information System (INIS)

    Raiskums, G.A.

    1991-01-01

    Digital control has been an integral part of Canada deuterium uranium (CANDU) nuclear power reactor technology since the 1960s. Much of the high CANDU production reliability can be attributed to the fault-tolerant and flexible control algorithms achievable with digital control. Atomic Energy of Canada Limited (AECL) has now transported this technology to research reactors, using industrial-grade microcomputers to solve equipment aging and spares obsolescence problems so prevalent at older installations. The open architecture of the Intel 8086-based computers provides for wide availability and reasonably priced, quality hardware from numerous sources. AECL recently supplied the Pennsylvania State University Breazeale Reactor (PSBR) with a new console containing a digital control and monitoring system. The reactor safety system (RSS) was also replaced with hardwired relay logic and truly analog state-of-the-art wide range nuclear instrumentation supplied by AECL's subcontractor, Gamma-Metrics. Retaining analog hardware for the mandated RSS functions was key to minimizing licensing efforts and the extensive verification and validation that would be required for safety system software. This paper elaborates on the digital control and monitoring portion of the PSBR console replacement, with emphasis on the key system objectives

  18. Supporting Self-Determined Indigenous Innovations: Rethinking the Digital Divide in Canada

    Directory of Open Access Journals (Sweden)

    Jasmin Winter

    2018-02-01

    Full Text Available This article seeks to revisit dominant narratives of digital technological development in Indigenous communities in Canada. By prioritizing Indigenous voices and drawing from concepts of self-determination and sovereignty, this analysis reorients discourse surrounding the “digital divide” towards a strength-based approach that positions Indigenous peoples as innovators and creators, not just consumers, of digital technologies. This article begins with a discussion of how dominant media has used technology and technological imagery to misrepresent Indigenous cultures and perpetuate colonial biases, and emphasizes the importance of making space for Indigenous future imagery. Following this is a discussion of digital storytelling and virtual landscapes, showcasing a small sample of Indigenous initiatives online, in video game and app development, and in augmented and virtual reality. Finally, this article considers the potential of “makerspaces” as a framework for future action to bridge theory and practice.

  19. Diffusion of the Digital Health Self-Tracking Movement in Canada: Results of a National Survey

    Science.gov (United States)

    Leaver, Chad; Bourget, Claire

    2018-01-01

    Background With the ever-increasing availability of mobile apps, consumer wearables, and smart medical devices, more and more individuals are self-tracking and managing their personal health data. Objective The aim of this study was to investigate the diffusion of the digital self-tracking movement in Canada. It provides a comprehensive, yet detailed account of this phenomenon. It examines the profile of digital self-trackers, traditional self-trackers, and nontrackers, further investigating the primary motivations for self-tracking and reasons for nontracking; barriers to adoption of connected care technologies; users’ appreciation of their self-tracking devices, including what they perceive to be the main benefits; factors that influence people’s intention to continue using connected care technologies in the future; and the reasons for usage discontinuance. Methods We conducted an online survey with a sample of 4109 Canadian adults, one of the largest ever. To ensure a representative sample, quota method was used (gender, age), following stratification by region. The maximum margin of error is estimated at 1.6%, 19 times out of 20. Results Our findings reveal that 66.20% (2720/4109) of our respondents regularly self-track one or more aspects of their health. About one in 4 respondents (1014/4109, 24.68%) currently owns a wearable or smart medical device, and 57.20% (580/1014) use their devices on a regular basis for self-tracking purposes. Digital self-trackers are typically young or mature adults, healthy, employed, university educated, with an annual family income of over $80,000 CAD. The most popular reported device is the fitness tracker or smartwatch that can capture a range of parameters. Currently, mobile apps and digital self-tracking devices are mainly used to monitor physical activity (856/1669, 51.13%), nutrition (545/1669, 32.65%), sleep patterns (482/1669, 28.88%) and, to a much lesser extent, cardiovascular and pulmonary biomarkers (215/1669, 12

  20. Analog and digital image quality:

    OpenAIRE

    Sardo, Alberto

    2004-01-01

    Background. Lastly the X ray facilities are moving to a slow, but continuous process of digitalization. The dry laser printers allow hardcopy images with optimum resolution and contrast for all the modalities. In breast imaging, thedelay of digitalization depends to the high cost of digital systems and, attimes, to the doubts of the diagnostic accuracy of reading the breast digital images. Conclusions. The Screen film mammography (SFM) is the most efficient diagnostic modality to detect the b...

  1. Digital control in LLRF system for CYCIAE-100 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhiguo, E-mail: bitbearAT@hotmail.com; Fu, Xiaoliang; Ji, Bin; Zhang, Tianjue; Wang, Chuan

    2016-05-21

    As a driven accelerator, the CYCIAE-100 cyclotron is designed by China Institute of Atomic Energy for the Beijing Radio Ion-beam Facility project. The cyclotron RF system is designed to use two RF power sources of 100 kW to drive two half-wavelength cavities respectively. Two Dee accelerating electrodes are kept separately from each other inside the cyclotron, while their accelerating voltages are maintained in phase by the efforts of LLRF control. An analog–digital hybrid LLRF system has been developed to achieve cavity tuning control, dee voltage amplitude and phase stabilization etc. The analog subsystems designs are focused on RF signal up/down conversion, tuning control, and dee voltage regulation. The digital system provides an RF signal source, aligns the cavity phases and maintains a Finite State Machine. The digital parts combine with the analog functions to provide the LLRF control. A brief system hardware introduction will be given in this paper, followed by the review of several major characteristics of the digital control in the 100 MeV cyclotron LLRF system. The commissioning is also introduced, and most of the optimization during the process was done by changing the digital parts.

  2. Digitally Controlled Converter with Dynamic Change of Control Law and Power Throughput

    DEFF Research Database (Denmark)

    Nesgaard, Carsten; Andersen, Michael Andreas E.; Nielsen, Nils

    2003-01-01

    the substitution of analog controllers with their digital counterparts are considered. The outline of the paper is divided into two segments – the first being an experimental analysis of the timing behavior by means of code optimization – the second being an examination of the dynamics of incorporating two control......With the continuous development of faster and cheaper microprocessors the field of applications for digital control is constantly expanding. Based on this trend the paper at hand describes the analysis and implementation of multiple control laws within the same controller. Also, implemented within...

  3. Market and Labour Control in Digital Capitalism

    Directory of Open Access Journals (Sweden)

    Philipp Staab

    2016-11-01

    Full Text Available Theorists of post capitalism have recently argued for a more or less inevitable end to capitalism. They assume that private accumulation is systematically blocked by the inability of capitalist corporations to create revenues by setting prices as they lose control over the reproduction of their commodities and that in this process, capitalist labour will eventually disappear. Drawing on a case study of Amazon and thoughts on the policies of other leading digital corporations, we challenge these assumptions. Key corporate players of digitization are trying to become powerful monopolies and have partly succeeded in doing so, using the network effects and scaling opportunities of digital goods and building socio-technical ecosystems. These strategies have led to the development of in part isomorphic structures, hence creating a situation of oligopolistic market competition. We draw on basic assumptions of monopoly capital theory to argue that in this situation labour process rationalization becomes key to the corporation’s competitive strategies. We see the expansion of digital control and the organizational structures applied by key corporate players of the digital economy as evidence for the expansion of capitalist labour, not its reduction.

  4. Digital Control of External Devices through the Parallel Port of a ...

    African Journals Online (AJOL)

    Digital Control of External Devices through the Parallel Port of a Computer Using Visual Basic. ... Nigerian Journal of Technology ... Keywords: device controller, digital switching, digital interfacing, visual basic, computer parallel port ...

  5. Target Diagnostics Supports NIF's Path to Ignition

    International Nuclear Information System (INIS)

    Shelton, R.

    2011-01-01

    The physics requirements derived from the National Ignition Facility (NIF) experimental campaigns are leading to a wide variety of target diagnostics. Software development for the control and analysis of these diagnostics is included in the NIF Integrated Computer Control System, Diagnostic Control System and Data Visualization. These projects implement the configuration, controls, data analysis and visual representation of most of these diagnostics. To date, over 40 target diagnostics have been developed to support NIF experiments. In 2011 diagnostics were developed or enhanced to measure Ignition performance in a high neutron yield environment. Performance is optimized around four key variables: Adiabat (a) which is the strength and timing of four shocks delivered to the target, Velocity (V) of the imploding target, Mix (M) is the uniformity of the burn, and the Shape (S) of the imploding Deuterium Tritium (DT) hot spot. The diagnostics used to measure each of these parameters is shown in figure 1. Adiabat is measured using the Velocity Interferometer System for Any Reflector (VISAR) diagnostic consisting of three streak cameras. To provide for more accurate adiabat measurements the VISAR streak cameras were enhanced in FY11 with a ten comb fiducial signal controller to allow for post shot correction of the streak camera sweep non-linearity. Mix is measured by the Neutron Time of Flight (NTOF) and Radiochemical Analysis of Gaseous Samples (RAGS) diagnostics. To accommodate high neutron yield shots, NTOF diagnostic controls are being modified to use Mach Zehnder interferometer signals to allow the digitizers to be moved from near the target chamber to the neutron shielded diagnostic mezzanine. In December 2011 the first phase of RAGS diagnostic commissioning will be completed. This diagnostic will analyze the tracers that are added to NIF target capsules that undergo nuclear reactions during the shot. These gases are collected and purified for nuclear counting by

  6. Upgrading the Reactor Power Control Concept with a Modern Digital Control System

    International Nuclear Information System (INIS)

    Laengle, M.; Schildheuer, R.

    2011-01-01

    Within the framework of a retrofit project, a reactor power instrumentation and control system (REALL) - consisting of a limiting system and the respective reactor control systems - was retrofitted and modernized in a 1450-MW-nuclear-power-plant in Baden-Wuerttemberg. The REALL process control functions were implemented within a modern and completely digitized control system that has been designed for use in safety I and C applications. Along with the installation of the digital control system, the associated hardware was adapted to today's state of the art. At the same time, the given potential for improvement, as revealed during the plant's operation so far, was taken into account in the programming. In order to provide for transparent and quality-assured project management, the implementation was based on a stage plan consisting of several steps, along with specific milestones. Final commissioning of the modern digital control system took place during the 2008 plant overhaul. Despite the complex commissioning procedure, it was possible to avoid a major prolongation of the plant's downtime and to keep within a rough 4-week timeframe that had originally been defined for the plant overhaul to adequate structuring of the project, goal-oriented implementation of preparatory infrastructural measures and adequate scheduling of the coordinated activities of the installation and commissioning teams entrusted with the commissioning of the digital control system during the overhaul activities. (author)

  7. Effortless self-control : A novel perspective on response conflict strategies in trait self-control

    NARCIS (Netherlands)

    Gillebaart, Marleen|info:eu-repo/dai/nl/344390365; de Ridder, Denise T D|info:eu-repo/dai/nl/070706174

    Self-control is of invaluable importance for well-being. While previous research has focused on self-control failure, we introduce a new perspective on self-control, including the notion of effortless self-control, and a focus on self-control success rather than failure. We propose that effortless

  8. Application of digital control techniques for satellite medium power DC-DC converters

    Science.gov (United States)

    Skup, Konrad R.; Grudzinski, Pawel; Nowosielski, Witold; Orleanski, Piotr; Wawrzaszek, Roman

    2010-09-01

    The objective of this paper is to present a work concerning a digital control loop system for satellite medium power DC-DC converters that is done in Space Research Centre. The whole control process of a described power converter bases on a high speed digital signal processing. The paper presents a development of a FPGA digital controller for voltage mode stabilization that was implemented using VHDL. The described controllers are a classical digital PID controller and a bang-bang controller. The used converter for testing is a simple model of 5-20 W, 200 kHz buck power converter. A high resolution digital PWM approach is presented. Additionally a simple and effective solution of filtering of an analog-to-digital converter output is presented.

  9. Integument pattern formation involves genetic and epigenetic controls: feather arrays simulated by digital hormone models.

    Science.gov (United States)

    Jiang, Ting-Xin; Widelitz, Randall B; Shen, Wei-Min; Will, Peter; Wu, Da-Yu; Lin, Chih-Min; Jung, Han-Sung; Chuong, Cheng-Ming

    2004-01-01

    Pattern formation is a fundamental morphogenetic process. Models based on genetic and epigenetic control have been proposed but remain controversial. Here we use feather morphogenesis for further evaluation. Adhesion molecules and/or signaling molecules were first expressed homogenously in feather tracts (restrictive mode, appear earlier) or directly in bud or inter-bud regions ( de novo mode, appear later). They either activate or inhibit bud formation, but paradoxically colocalize in the bud. Using feather bud reconstitution, we showed that completely dissociated cells can reform periodic patterns without reference to previous positional codes. The patterning process has the characteristics of being self-organizing, dynamic and plastic. The final pattern is an equilibrium state reached by competition, and the number and size of buds can be altered based on cell number and activator/inhibitor ratio, respectively. We developed a Digital Hormone Model which consists of (1) competent cells without identity that move randomly in a space, (2) extracellular signaling hormones which diffuse by a reaction-diffusion mechanism and activate or inhibit cell adhesion, and (3) cells which respond with topological stochastic actions manifested as changes in cell adhesion. Based on probability, the results are cell clusters arranged in dots or stripes. Thus genetic control provides combinational molecular information which defines the properties of the cells but not the final pattern. Epigenetic control governs interactions among cells and their environment based on physical-chemical rules (such as those described in the Digital Hormone Model). Complex integument patterning is the sum of these two components of control and that is why integument patterns are usually similar but non-identical. These principles may be shared by other pattern formation processes such as barb ridge formation, fingerprints, pigmentation patterning, etc. The Digital Hormone Model can also be applied to

  10. Quality control of the interpretation monitors of digital radiological images

    International Nuclear Information System (INIS)

    Favero, Mariana S.; Goulart, Adriano Oliveira S.

    2016-01-01

    The performance monitors has great importance in image quality of digital radiographic systems. In environments without films, it became necessary to implement acceptance testing and quality control monitors used for interpretation of medical images. The monitors dedicated to radiodiagnostic should provide information that represent slight differences in x-ray attenuation or minor differences in some anatomical region of interest. This should also result in small differences in luminance of an image represented. Factors affecting the quality of medical imaging are contrast, noise, resolution, artifacts and distortions. Therefore, a monitor must have specific characteristics, making it possible for the observer to carry out an assessment that leads to better diagnosis. Based on the need to evaluate diagnostic monitors in various radiological applications, this paper presents a summary for implementation and standardization of tests that are recommended by the publication AAPM Report 03. (author)

  11. [The Offer of Medical-Diagnostic Self-Tests on German Language Websites: Results of a Systematic Internet Search].

    Science.gov (United States)

    Kuecuekbalaban, P; Schmidt, S; Muehlan, H

    2018-03-01

    The aim of the current study was to provide an overview of medical-diagnostic self-tests which can be purchased without a medical prescription on German language websites. From September 2014 to March 2015, a systematic internet research was conducted with the following search terms: self-test, self-diagnosis, home test, home diagnosis, quick test, rapid test. 513 different self-tests for the diagnostics of 52 diverse diseases or health risks were identified, including chronic diseases (e. g. diabetes, chronic disease of the kidneys, liver, and lungs), sexually transmitted diseases (e. g. HIV, chlamydia, gonorrhea), infectious diseases (e. g. tuberculosis, malaria, Helicobacter pylori), allergies (e. g. house dust, cats, histamine) and cancer as well as tests for the diagnostics of 12 different psychotropic substances. These were sold by 90 companies in Germany and by other foreign companies. The number of medical-diagnostic self-tests which can be bought without a medical prescription on the Internet has increased enormously in the last 10 years. Further studies are needed for the identification of the determinants of the use of self-tests as well as the impact of the application on the experience and behavior of the user. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Optimal sampling period of the digital control system for the nuclear power plant steam generator water level control

    International Nuclear Information System (INIS)

    Hur, Woo Sung; Seong, Poong Hyun

    1995-01-01

    A great effort has been made to improve the nuclear plant control system by use of digital technologies and a long term schedule for the control system upgrade has been prepared with an aim to implementation in the next generation nuclear plants. In case of digital control system, it is important to decide the sampling period for analysis and design of the system, because the performance and the stability of a digital control system depend on the value of the sampling period of the digital control system. There is, however, currently no systematic method used universally for determining the sampling period of the digital control system. Generally, a traditional way to select the sampling frequency is to use 20 to 30 times the bandwidth of the analog control system which has the same system configuration and parameters as the digital one. In this paper, a new method to select the sampling period is suggested which takes into account of the performance as well as the stability of the digital control system. By use of the Irving's model steam generator, the optimal sampling period of an assumptive digital control system for steam generator level control is estimated and is actually verified in the digital control simulation system for Kori-2 nuclear power plant steam generator level control. Consequently, we conclude the optimal sampling period of the digital control system for Kori-2 nuclear power plant steam generator level control is 1 second for all power ranges. 7 figs., 3 tabs., 8 refs. (Author)

  13. A review of digital radiography technology for valve inspection

    International Nuclear Information System (INIS)

    Stoev, K.; Guerout, F.M.; Horn, D.

    2008-01-01

    There are thousands of valves in a nuclear power plant (NPP) used for control, safety and checks in various plant systems, so there is a well-identified need for fast and reliable inspection and diagnostics of valves. Digital radiography can provide considerable improvements to the inspection and testing procedures for valves in comparison to classical film radiography. These improvements can lead to significant financial advantages by providing real-time inspection results, significantly reduced inspection and decision-making time, and reduced operational cost. Digital image processing, including digital image enhancement, digital archiving, and digital communication of the images and the results, is also a considerable advantage over classical film radiography technology. Another advantage of digital radiography technology is the improved safety and the reduced environmental impact due to reduced exposure/test times, use of smaller exclusion zones, elimination of chemical processing, and absence of disposable materials. This paper reviews the existing technology and evaluates the potential of digital radiography for inspection and diagnostics of valves. Station needs and requirements are assessed, and the safety, environmental and economical constraints of digital radiography techniques estimated. The advantages and disadvantages of different digital radiography equipment are compared, and their limitations and characteristics studied. (author)

  14. Advantages of the nested case-control design in diagnostic research

    Directory of Open Access Journals (Sweden)

    Hoes Arno W

    2008-07-01

    Full Text Available Abstract Background Despite its benefits, it is uncommon to apply the nested case-control design in diagnostic research. We aim to show advantages of this design for diagnostic accuracy studies. Methods We used data from a full cross-sectional diagnostic study comprising a cohort of 1295 consecutive patients who were selected on their suspicion of having deep vein thrombosis (DVT. We draw nested case-control samples from the full study population with case:control ratios of 1:1, 1:2, 1:3 and 1:4 (per ratio 100 samples were taken. We calculated diagnostic accuracy estimates for two tests that are used to detect DVT in clinical practice. Results Estimates of diagnostic accuracy in the nested case-control samples were very similar to those in the full study population. For example, for each case:control ratio, the positive predictive value of the D-dimer test was 0.30 in the full study population and 0.30 in the nested case-control samples (median of the 100 samples. As expected, variability of the estimates decreased with increasing sample size. Conclusion Our findings support the view that the nested case-control study is a valid and efficient design for diagnostic studies and should also be (reappraised in current guidelines on diagnostic accuracy research.

  15. Sub–100-nm metafluorophores with digitally tunable optical properties self-assembled from DNA

    Science.gov (United States)

    Woehrstein, Johannes B.; Strauss, Maximilian T.; Ong, Luvena L.; Wei, Bryan; Zhang, David Y.; Jungmann, Ralf; Yin, Peng

    2017-01-01

    Fluorescence microscopy allows specific target detection down to the level of single molecules and has become an enabling tool in biological research. To transduce the biological information to an imageable signal, we have developed a variety of fluorescent probes, such as organic dyes or fluorescent proteins with different colors. Despite their success, a limitation on constructing small fluorescent probes is the lack of a general framework to achieve precise and programmable control of critical optical properties, such as color and brightness. To address this challenge, we introduce metafluorophores, which are constructed as DNA nanostructure–based fluorescent probes with digitally tunable optical properties. Each metafluorophore is composed of multiple organic fluorophores, organized in a spatially controlled fashion in a compact sub–100-nm architecture using a DNA nanostructure scaffold. Using DNA origami with a size of 90 × 60 nm2, substantially smaller than the optical diffraction limit, we constructed small fluorescent probes with digitally tunable brightness, color, and photostability and demonstrated a palette of 124 virtual colors. Using these probes as fluorescent barcodes, we implemented an assay for multiplexed quantification of nucleic acids. Additionally, we demonstrated the triggered in situ self-assembly of fluorescent DNA nanostructures with prescribed brightness upon initial hybridization to a nucleic acid target. PMID:28691083

  16. Digitally controlled analog proportional-integral-derivative (PID) controller for high-speed scanning probe microscopy

    Science.gov (United States)

    Dukic, Maja; Todorov, Vencislav; Andany, Santiago; Nievergelt, Adrian P.; Yang, Chen; Hosseini, Nahid; Fantner, Georg E.

    2017-12-01

    Nearly all scanning probe microscopes (SPMs) contain a feedback controller, which is used to move the scanner in the direction of the z-axis in order to maintain a constant setpoint based on the tip-sample interaction. The most frequently used feedback controller in SPMs is the proportional-integral (PI) controller. The bandwidth of the PI controller presents one of the speed limiting factors in high-speed SPMs, where higher bandwidths enable faster scanning speeds and higher imaging resolution. Most SPM systems use digital signal processor-based PI feedback controllers, which require analog-to-digital and digital-to-analog converters. These converters introduce additional feedback delays which limit the achievable imaging speed and resolution. In this paper, we present a digitally controlled analog proportional-integral-derivative (PID) controller. The controller implementation allows tunability of the PID gains over a large amplification and frequency range, while also providing precise control of the system and reproducibility of the gain parameters. By using the analog PID controller, we were able to perform successful atomic force microscopy imaging of a standard silicon calibration grating at line rates up to several kHz.

  17. Proceedings: Electromagnetic interference control in modern digital instrumentation and control upgrades

    International Nuclear Information System (INIS)

    1993-06-01

    A workshop on Electro-Magnetic Interference (EMI) Control in Modern Digital Instrumentation ampersand Control System Upgrade was held in Baltimore on September 10-11, 1992 to provide a forum for technology transfer, technical information exchange, and education. The workshop was attended by more than 70 representatives of electric utilities, equipment manufacturers, engineering consulting organizations, and government agencies. The workshop consists of four sessions: (1) Organizational EMC Perspectives, (2) EMI Environment, Case Histories ampersand Solutions, (3) EMC in Digital Instrumentation ampersand Control Systems, and (4) EMI Utility Needs. A group discussion followed the presentations to identify utility needs. Individual papers have been cataloged separately

  18. Diffusion of the Digital Health Self-Tracking Movement in Canada: Results of a National Survey.

    Science.gov (United States)

    Paré, Guy; Leaver, Chad; Bourget, Claire

    2018-05-02

    With the ever-increasing availability of mobile apps, consumer wearables, and smart medical devices, more and more individuals are self-tracking and managing their personal health data. The aim of this study was to investigate the diffusion of the digital self-tracking movement in Canada. It provides a comprehensive, yet detailed account of this phenomenon. It examines the profile of digital self-trackers, traditional self-trackers, and nontrackers, further investigating the primary motivations for self-tracking and reasons for nontracking; barriers to adoption of connected care technologies; users' appreciation of their self-tracking devices, including what they perceive to be the main benefits; factors that influence people's intention to continue using connected care technologies in the future; and the reasons for usage discontinuance. We conducted an online survey with a sample of 4109 Canadian adults, one of the largest ever. To ensure a representative sample, quota method was used (gender, age), following stratification by region. The maximum margin of error is estimated at 1.6%, 19 times out of 20. Our findings reveal that 66.20% (2720/4109) of our respondents regularly self-track one or more aspects of their health. About one in 4 respondents (1014/4109, 24.68%) currently owns a wearable or smart medical device, and 57.20% (580/1014) use their devices on a regular basis for self-tracking purposes. Digital self-trackers are typically young or mature adults, healthy, employed, university educated, with an annual family income of over $80,000 CAD. The most popular reported device is the fitness tracker or smartwatch that can capture a range of parameters. Currently, mobile apps and digital self-tracking devices are mainly used to monitor physical activity (856/1669, 51.13%), nutrition (545/1669, 32.65%), sleep patterns (482/1669, 28.88%) and, to a much lesser extent, cardiovascular and pulmonary biomarkers (215/1669, 12.88%), medication intake (126/1669, 7

  19. Calculation of Digital Control Circuits using Scilab Environment

    Directory of Open Access Journals (Sweden)

    Petru Chioncel

    2015-09-01

    Full Text Available The paper presents the computing of digital control circuits using Scilab environment. It exemplifies the influence of the sampling time in case of a transfer system described by a PT3 element composed of one PT1 and one PT2 element. For a continuous control system, the transfer function in z is computed and replaced with a digital control system. The presented calculation, done in Scilab, highlights the test responses of the process evidencing the systems performances.

  20. Latex glove sensitivity amongst diagnostic imaging healthcare personnel: a self-reporting investigation

    International Nuclear Information System (INIS)

    Healy, Jan; Brennan, Patrick C.; Bowden, Julie Anne

    2003-01-01

    The use of latex gloves has risen dramatically among healthcare workers resulting in an increase in the number of workers experiencing reactions to gloves. Little evidence of reactions among Irish healthcare workers is available. The current, self-reporting study investigated the prevalence to latex gloves amongst four professional groups within three Diagnostic Imaging Departments. Prevalence is similar to that demonstrated elsewhere with 18.3% of individuals expressing latex associated symptoms. Symptoms included itching and redness of hands, dry cracked skin, soreness of eyes and upper respiratory tract complaints. These results indicate that latex hypersensitivity is a real problem amongst Irish healthcare workers. This preliminary work provides the basis of a much larger controlled study currently being planned

  1. Happy ending: a randomized controlled trial of a digital multi-media smoking cessation intervention.

    Science.gov (United States)

    Brendryen, Håvar; Kraft, Pål

    2008-03-01

    To assess the long-term efficacy of a fully automated digital multi-media smoking cessation intervention. Two-arm randomized control trial (RCT). Setting World Wide Web (WWW) study based in Norway. Subjects (n = 396) were recruited via internet advertisements and assigned randomly to conditions. Inclusion criteria were willingness to quit smoking and being aged 18 years or older. The treatment group received the internet- and cell-phone-based Happy Ending intervention. The intervention programme lasted 54 weeks and consisted of more than 400 contacts by e-mail, web-pages, interactive voice response (IVR) and short message service (SMS) technology. The control group received a self-help booklet. Additionally, both groups were offered free nicotine replacement therapy (NRT). Abstinence was defined as 'not even a puff of smoke, for the last 7 days', and assessed by means of internet surveys or telephone interviews. The main outcome was repeated point abstinence at 1, 3, 6 and 12 months following cessation. Participants in the treatment group reported clinically and statistically significantly higher repeated point abstinence rates than control participants [22.3% versus 13.1%; odds ratio (OR) = 1.91, 95% confidence interval (CI): 1.12-3.26, P = 0.02; intent-to-treat). Improved adherence to NRT and a higher level of post-cessation self-efficacy were observed in the treatment group compared with the control group. As the first RCT documenting the long-term treatment effects of such an intervention, this study adds to the promise of digital media in supporting behaviour change.

  2. Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2014-01-01

    Full Text Available Background: To evaluate the diagnostic accuracy of different radiographic methods in the assessment of proximal alveolar bone loss (ABL. Materials and Methods: ABL, the distance between cement-enamel junction and alveolar bone crest, was measured in 70 mandibular human teeth - directly on the mandibles (control, using conventional periapical radiography with film holders (Rinn XCP and Han-Shin, digital periapical radiography with complementary metal-oxide semiconductor sensor, conventional panoramic, and cone-beam computed tomography (CBCT. Three programs were used to measure ABL on the images: Image tool 3.0 (University of Texas Health Sciences Center, San Antonio, Texas, USA, Kodak Imaging 6.1 (Kodak Dental Imaging 6.1, Carestream Health ® , Rochester, NY, USA, and i-CAT vision 1.6.20. Statistical analysis used ANOVA and Tukey′s test at 5% significance level. Results: The tomographic images showed the highest means, whereas the lowest were found for periapical with Han-Shin. Controls differed from periapical with Han-Shin (P < 0.0001. CBCT differed from panoramic (P = 0.0130, periapical with Rinn XCP (P = 0.0066, periapical with Han-Shin (P < 0.0001, and digital periapical (P = 0.0027. Conventional periapicals with film holders differed from each other (P = 0.0007. Digital periapical differed from conventional periapical with Han-Shin (P = 0.0004. Conclusions: Conventional periapical with Han-Shin film holder was the only method that differed from the controls. CBCT had the closest means to the controls.

  3. Preanalytical blood sample workup for cell-free DNA analysis using Droplet Digital PCR for future molecular cancer diagnostics

    NARCIS (Netherlands)

    van Ginkel, Joost H.; van den Broek, Daan A.; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M.; Huibers, Manon M.H.

    2017-01-01

    In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for

  4. Diagnostic Performance of Self-Assessment for Constipation in Patients With Long-Term Opioid Treatment.

    Science.gov (United States)

    Tafelski, Sascha; Bellin, Felicitas; Denke, Claudia; Beutlhauser, Torsten; Fritzsche, Thomas; West, Christina; Schäfer, Michael

    2015-12-01

    Constipation is a prevalent comorbidity affecting ∼50% of patients with long-term opioid therapy. In clinical routine different diagnostic instruments are in use to identify patients under risk. The aim of this study was to assess the diagnostic performance of an 11-item Likert scale for constipation used as a self-assessment in opioid-treated patients. This trial was conducted as a retrospective cohort study in Berlin, Germany. Patients with long-term opioid therapy treated in 2 university-affiliated outpatient pain facilities at the Charité hospital were included from January 2013 to August 2013. Constipation was rated in a self-assessment using a numeric rating scale from 0 to 10 (Con-NRS) and compared with results from a structured assessment based on ROME-III criteria. Altogether, 171 patients were included. Incidence of constipation was 49% of patients. The receiver-operating characteristic of Con-NRS achieved an area under the curve of 0.814 (AUC 95% confidence interval 0.748-0.880, P < 0.001). Con-NRS ≥ 1 achieved sensitivity and specificity of 79.7% and 77.2%, respectively. The positive predictive value and the negative predictive value were 70.3% and 81.6%, respectively. Overall diagnostic performance of a concise 11-item Likert scale for constipation was moderate. Although patients with long-term opioid therapy are familiar with numeric rating scales, a significant number of patients with constipation were not identified. The instrument may be additionally useful to facilitate individualized therapeutic decision making and to control therapeutic success when measured repetitively.

  5. Digital radiography and caries diagnosis.

    Science.gov (United States)

    Wenzel, A

    1998-01-01

    Direct digital acquisition of intra-oral radiographs has been possible only in the last decade. Several studies have shown that, theoretically, there are a number of advantages of direct digital radiography compared with conventional film. Laboratory as well as controlled clinical studies are needed to determine whether new digital imaging systems alter diagnosis, treatment and prognosis compared with conventional methods. Most studies so far have evaluated their diagnostic performance only in laboratory settings. This review concentrates on what evidence we have for the diagnostic efficacy of digital systems for caries detection. Digital systems are compared with film and those studies which have evaluated the effects on diagnostic accuracy of contrast and edge enhancement, image size, variations in radiation dose and image compression are reviewed together with the use of automated image analysis for caries diagnosis. Digital intra-oral radiographic systems seem to be as accurate as the currently available dental films for the detection of caries. Sensitivities are relatively high (0.6-0.8) for detection of occlusal lesions into dentine with false positive fractions of 5-10%. A radiolucency in dentine is recognised as a good predictor for demineralisation. Radiography is of no value for the detection of initial (enamel) occlusal lesions. For detection of approximal dentinal lesions, sensitivities, specificities as well as the predictive values are fair, but are very poor for lesions known to be confined to enamel. Very little documented information exists, however, on the utilization of digital systems in the clinic. It is not known whether dose is actually reduced with the storage phosphor system, or whether collimator size is adjusted to fit sensor size in the CCD-based systems. There is no evidence that the number of retakes have been reduced. It is not known how many images are needed with the various CCD systems when compared with a conventional bitewing

  6. Digital control for nuclear reactors - lessons learned

    International Nuclear Information System (INIS)

    Bernard, J.A.; Aviles, B.N.; Lanning, D.D.

    1992-01-01

    Lessons learned during the course of the now decade-old MIT program on the digital control of nuclear reactors are enumerated. Relative to controller structure, these include the importance of a separate safety system, the need for signal validation, the role of supervisory algorithms, the significance of command validation, and the relevance of automated reasoning. Relative to controller implementation, these include the value of nodal methods to the creation of real-time reactor physics and thermal hydraulic models, the advantages to be gained from the use of real-time system models, and the importance of a multi-tiered structure to the simultaneous achievement of supervisory, global, and local control. Block diagrams are presented of proposed controllers and selected experimental and simulation-study results are shown. In addition, a history is given of the MIT program on reactor digital control

  7. Digital Resonant Controller based on Modified Tustin Discretization Method

    Directory of Open Access Journals (Sweden)

    STOJIC, D.

    2016-11-01

    Full Text Available Resonant controllers are used in power converter voltage and current control due to their simplicity and accuracy. However, digital implementation of resonant controllers introduces problems related to zero and pole mapping from the continuous to the discrete time domain. Namely, some discretization methods introduce significant errors in the digital controller resonant frequency, resulting in the loss of the asymptotic AC reference tracking, especially at high resonant frequencies. The delay compensation typical for resonant controllers can also be compromised. Based on the existing analysis, it can be concluded that the Tustin discretization with frequency prewarping represents a preferable choice from the point of view of the resonant frequency accuracy. However, this discretization method has a shortcoming in applications that require real-time frequency adaptation, since complex trigonometric evaluation is required for each frequency change. In order to overcome this problem, in this paper the modified Tustin discretization method is proposed based on the Taylor series approximation of the frequency prewarping function. By comparing the novel discretization method with commonly used two-integrator-based proportional-resonant (PR digital controllers, it is shown that the resulting digital controller resonant frequency and time delay compensation errors are significantly reduced for the novel controller.

  8. Applying the multi-threat framework of stereotype threat in the context of digital gaming

    OpenAIRE

    Pennington, C. R.; Kaye, L. K.; McCann, J. J.

    2018-01-01

    Females often report experiencing stigmatisation pertaining to their competency in digital gaming communities. Employing the principles of the multi-threat framework of stereotype threat, the current research examined the impact of gender-related stereotypes on females' gaming performance and related self-perceptions. In Experiment 1, 90 females were assigned to one of three conditions in which they were primed that their performance would be either diagnostic of their personal (self-as-targe...

  9. Interactive Digital e-Health Game for Heart Failure Self-Management: A Feasibility Study

    Science.gov (United States)

    Toprac, Paul; O'Hair, Matt; Bias, Randolph; Kim, Miyong T.; Bradley, Paul; Mackert, Michael

    2016-01-01

    Abstract Objective: To develop and test the prototype of a serious digital game for improving community-dwelling older adults' heart failure (HF) knowledge and self-management behaviors. The serious game innovatively incorporates evidence-based HF guidelines with contemporary game technology. Materials and Methods: The study included three phases: development of the game prototype, its usability assessment, and evaluation of the game's functionality. Usability testing included researchers' usability assessment, followed by research personnel's observations of participants playing the game, and participants' completion of a usability survey. Next, in a pretest–post-test design, validated instruments—the Atlanta Heart Failure Knowledge Test and the Self Care for Heart Failure Index—were used to measure improvement in HF self-management knowledge and behaviors related to HF self-maintenance, self-management, and self-efficacy, respectively. A postgame survey assessed participants' perceptions of the game. Results: During usability testing, with seven participants, 100%, 100%, and 86% found the game easy to play, enjoyable, and helpful for learning about HF, respectively. In the subsequent functionality testing, with 19 participants, 89% found the game interesting, enjoyable, and easy to play. Playing the game resulted in a significant improvement in HF self-management knowledge, a nonsignificant improvement in self-reported behaviors related to HF self-maintenance, and no difference in HF self-efficacy scores. Participants with lower education level and age preferred games to any other medium for receiving information. Conclusion: It is feasible to develop a serious digital game that community-dwelling older adults with HF find both satisfying and acceptable and that can improve their self-management knowledge. PMID:27976955

  10. Technical quality control - constancy controls for digital mammography systems

    International Nuclear Information System (INIS)

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  11. MAS2-8 radar and digital control unit

    Science.gov (United States)

    Oberg, J. M.; Ulaby, F. T.

    1974-01-01

    The design of the MAS 2-8 (2 to 8 GHz microwave-active spectrometer), a ground-based sensor system, is presented. A major modification in 1974 to the MAS 2-8, that of a control subsystem to automate the data-taking operation, is the prime focus. The digital control unit automatically changes all system parameters except FM rate and records the return signal on paper tape. The overall system operation and a detailed discussion of the design and operation of the digital control unit are presented.

  12. Parameters-adjustable front-end controller in digital nuclear measurement system

    International Nuclear Information System (INIS)

    Hao Dejian; Zhang Ruanyu; Yan Yangyang; Wang Peng; Tang Changjian

    2013-01-01

    Background: One digitizer is used to implement a digital nuclear measurement for the acquisition of nuclear information. Purpose: A principle and method of a parameter-adjustable front-end controller is presented for the sake of reducing the quantitative errors while getting the maximum ENOB (effective number of bits) of ADC (analog-to-digital converter) during waveform digitizing, as well as reducing the losing counts. Methods: First of all, the quantitative relationship among the radiation count rate (n), the amplitude of input signal (V in ), the conversion scale of ADC (±V) and the amplification factor (A) was derived. Secondly, the hardware and software of the front-end controller were designed to fulfill matching the output of different detectors, adjusting the amplification linearly through the control of channel switching, and setting of digital potentiometer by CPLD (Complex Programmable Logic Device). Results: (1) Through the measurement of γ-ray of Am-241 under our digital nuclear measurement set-up with CZT detector, it was validated that the amplitude of output signal of detectors of RC feedback type could be amplified linearly with adjustable amplification by the front-end controller. (2) Through the measurement of X-ray spectrum of Fe-5.5 under our digital nuclear measurement set-up with Si-PIN detector, it was validated that the front-end controller was suitable for the switch resetting type detectors, by which high precision measurement under various count rates could be fulfilled. Conclusion: The principle and method of the parameter-adjustable front-end controller presented in this paper is correct and feasible. (authors)

  13. Digital control of plasma position in Damavand tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Emami, M.; Babazadeh, A.R.; Roshan, M.V.; Memarzadeh, M.; Habibi, H. [Atomic Energy Organization of Iran (AEOI), Tehran (Iran, Islamic Republic of). Nuclear Fusion Research Center. Plasma Physics Lab.

    2002-03-01

    Plasma position control is one of the important issues in the design and operation of tokamak fusion research device. Since a tokamak is basically an electrical system consisting of power supplies, coils, plasma and eddy currents, a model in which these components are treated as an electrical circuits is used in designing Damavand plasma position control system. This model is used for the simulation of the digital control system and its parameters have been verified experimentally. In this paper, the performance of a high-speed digital controller as well as a simulation study and its application to the Damavand tokamak is discussed. (author)

  14. Digitizing instrumentation and control systems in nuclear power plants. DAtF autumn meeting Leittec '96, October 8, 1996 in Koenigswinter

    International Nuclear Information System (INIS)

    Aleite, W.

    1997-01-01

    Recently, digitization for upgrading and retrofitting of instrumentation and control systems has been extended to German nuclear power plants, and initial action to commence modification started with a very suitable system, the limiters of the Neckar-1 reactor unit of GKN. This action is generally welcomed. Systems of the control room of relevance to safety -even if not belonging to priority classes - are systems for process information for example, or operator guidance, as well as diagnostic systems for inspection and maintenance. (orig./DG) [de

  15. TFTR diagnostic control and data acquisition system

    International Nuclear Information System (INIS)

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-01-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development

  16. Digital control of high-frequency switched-mode power converters

    CERN Document Server

    Corradini, Luca; Mattavelli, Paolo; Zane, Regan

    This book is focused on the fundamental aspects of analysis, modeling and design of digital control loops around high-frequency switched-mode power converters in a systematic and rigorous manner Comprehensive treatment of digital control theory for power converters Verilog and VHDL sample codes are provided Enables readers to successfully analyze, model, design, and implement voltage, current, or multi-loop digital feedback loops around switched-mode power converters Practical examples are used throughout the book to illustrate applications of the techniques developed Matlab examples are also

  17. Unexpected Self-Expression and the Limits of Narrative Inquiry: Exploring Unconscious Dynamics in a Community-Based Digital Storytelling Workshop

    Science.gov (United States)

    Brushwood Rose, Chloe; Granger, Colette A.

    2013-01-01

    This study explores the tension between self-knowledge and self-expression, and how it manifests in the processes of storytelling that unfold in digital storytelling workshops offered to new immigrant women living in Toronto, Canada. Both in their multi-modal complexity and in the significant shifts from their original telling, the digital stories…

  18. Digital Native Preservice Teachers: An Examination of Their Self-Efficacy Beliefs Regarding Technology Integration in Classroom Settings

    Science.gov (United States)

    Southall, Sarah Parker

    2012-01-01

    The purpose of this mixed-method study was to investigate digital native preservice teachers' self-efficacy beliefs regarding their technology experiences and skills at the beginning and at the end of their field placement semester. Digital natives, as defined by Prensky (2001), are students born after 1980 who have been raised with digital media…

  19. Virtual instrument for controlling and monitoring digitalized power supply in SSRF

    International Nuclear Information System (INIS)

    Tang Junlong; Chen Huanguang; Chinese Academy of Sciences, Beijing; Xu Ruinian; Shen Tianjian; Li Deming

    2006-01-01

    The Shanghai Synchrotron Radiation Facility (SSRF) needs extremely precise power supplies for their various magnets. A digital controller is being developed for the power converters of the SSRF power supply (PS). In the digital controller, a fully digital pulse-width modulator (PWM) directly controls the power unit insulated gate bipolar transistor (IGBT) of the PS. A program in LabVIEW language has been developed to control and monitor the digital PS via serial communication (RS232) from a PC and to modify its parameters as well. In this article, the software design of the virtual instrument for controlling and monitoring digitalized PS and its associated functions are described, and the essential elements of the program graphical main-VI and sub-VI source code are presented and explained. The communication protocol and the structure of the developed system are also included in this article. (authors)

  20. The reactor power control system based on digital control in nuclear power plant

    International Nuclear Information System (INIS)

    Liu Chong; Zhou Jianliang; Tan Ping

    2010-01-01

    The PLC (Programmable Logical Controller), digital communication and redundant techniques are applied in the rod control and position indication system(namely the reactor power control system) to perform the power control in the 300 MW reactor automatically and integrally in Qinshan Phase I project. This paper introduces the features, digital design methods of hardware of the instrumentation and control system (I and C) in the reactor power control. It is more convenient for the information exchange by human-machine interface (HMI), operation and maintenance, and the system reliability has been greatly improved after the project being reconstructed. (authors)

  1. The Reliability and Validity of the Panic Disorder Self-Report: A New Diagnostic Screening Measure of Panic Disorder

    Science.gov (United States)

    Newman, Michelle G.; Holmes, Marilyn; Zuellig, Andrea R.; Kachin, Kevin E.; Behar, Evelyn

    2006-01-01

    This study examined the Panic Disorder Self-Report (PDSR), a new self-report diagnostic measure of panic disorder based on the 4th edition of the Diagnostic and Statistical Manual of Mental Disorders (American Psychiatric Association, 1994). PDSR diagnoses were compared with structured interview diagnoses of individuals with generalized anxiety…

  2. Measurement of proton-beam parameters by means of digital television diagnostic system

    International Nuclear Information System (INIS)

    Vazhenin, V.A.; Borovkov, S.D.; Evtikhiev, A.V.

    1992-01-01

    A method is described for measurement of the parameters of pulse-packet beams by means of a digital television diagnostic system. Results of tests of the system in measurement of the parameters of a proton beam with an energy of 1.35 GeV in the U-70 circular accelerator and results of measurements of the energy spectrum of the 30-MeV proton beam of the LU-30 linear accelerator are given. The possibility is shown of using the system to measure the integrated characteristics of an entire beam-pulse packet as well as the characteristics of individual pulses with a period of 60 msec. 6 refs., 4 figs., 1 tab

  3. Three-Dimensional Imaging by Self-Reference Single-Channel Digital Incoherent Holography

    Science.gov (United States)

    Rosen, Joseph; Kelner, Roy

    2016-01-01

    Digital holography offers a reliable and fast method to image a three-dimensional scene from a single perspective. This article reviews recent developments of self-reference single-channel incoherent hologram recorders. Hologram recorders in which both interfering beams, commonly referred to as the signal and the reference beams, originate from the same observed objects are considered as self-reference systems. Moreover, the hologram recorders reviewed herein are configured in a setup of a single channel interferometer. This unique configuration is achieved through the use of one or more spatial light modulators. PMID:28757811

  4. Design type testing for digital instrumentation and control systems

    International Nuclear Information System (INIS)

    Bastl, W.; Mohns, G.

    1997-01-01

    The design type qualification of digital safety instrumentation and control is outlined. Experience shows that the concepts discussed, derived from codes, guidelines and standards, achieve useful results. It has likewise become clear that the systematics of design type qualification of the hardware components is also applicable to the software components. Design type qualification of the software, a premiere, could be performed unexpectedly smoothly. The hardware design type qualification proved that the hardware as a substrate of functionality and reliability is an issue that demands full attention, as compared to conventional systems. Another insight is that design qualification of digital instrumentation and control systems must include plant-independent systems tests. Digital instrumentation and control systems simply work very differently from conventional control systems, so that this testing modality is inevitable. (Orig./CB) [de

  5. SIMULACIÓN DE CONTROLADORES DIGITALES SIMULATION OF DIGITAL CONTROLLERS

    Directory of Open Access Journals (Sweden)

    Carlos Álvarez G

    2009-12-01

    Full Text Available El presente trabajo tiene como objetivo la implementación de controladores digitales en un entorno de simulación controlado, para esto se desarrolla una plataforma de hardware que permite ejecutar los programas en lenguaje C generados en una estación de trabajo. Estos programas corresponden al controlador y a la planta que son generados por un software que genera dichos programas a partir de sus parámetros de modelación aplicando teoría de control digital sobre procesos reales.This paper describes an implementation of digital controllers in a simulation environment for including a hardware platform for running programs generated on a workstation. These programs for both the controller and the plant are generated by software based on parameters using digital control theory for real processes.

  6. Comparison of the diagnostic performance of digital breast tomosynthesis and magnetic resonance imaging added to digital mammography in women with known breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Hwa; Chang, Jung Min; Moon, Woo Kyung [Seoul National University Hospital, Department of Radiology, 101 Daehangno, Jongno-gu, Seoul (Korea, Republic of); Moon, Hyeong-Gon [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of); Yi, Ann [Seoul National University Hospital, Department of Radiology, Gangnan Healthcare Center, Seoul (Korea, Republic of); Koo, Hye Ryoung [Hanyang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Gweon, Hye Mi [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2016-06-15

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to mammography in women with known breast cancers. Three radiologists independently reviewed image sets of 172 patients with 184 cancers; mammography alone, DBT plus mammography and MRI plus mammography, and scored for cancer probability using the Breast Imaging Reporting and Data System (BI-RADS). Jack-knife alternative free-response receiver-operating characteristic (JAFROC), which allows diagnostic performance estimation using single lesion as a statistical unit in a cancer-only population, was used. Sensitivity and positive predictive value (PPV) were compared using the McNemar and Fisher-exact tests. The JAFROC figures of merit (FOMs) was lower in DBT plus mammography (0.937) than MRI plus mammography (0.978, P = 0.0006) but higher than mammography alone (0.900, P = 0.0013). The sensitivity was lower in DBT plus mammography (88.2 %) than MRI plus mammography (97.8 %) but higher than mammography alone (78.3 %, both P < 0.0001). The PPV was significantly higher in DBT plus mammography (93.3 %) than MRI plus mammography (89.6 %, P = 0.0282). DBT provided lower diagnostic performance than MRI as an adjunctive imaging to mammography. However, DBT had higher diagnostic performance than mammography and higher PPV than MRI. (orig.)

  7. Comparison of the diagnostic performance of digital breast tomosynthesis and magnetic resonance imaging added to digital mammography in women with known breast cancers

    International Nuclear Information System (INIS)

    Kim, Won Hwa; Chang, Jung Min; Moon, Woo Kyung; Moon, Hyeong-Gon; Yi, Ann; Koo, Hye Ryoung; Gweon, Hye Mi

    2016-01-01

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to mammography in women with known breast cancers. Three radiologists independently reviewed image sets of 172 patients with 184 cancers; mammography alone, DBT plus mammography and MRI plus mammography, and scored for cancer probability using the Breast Imaging Reporting and Data System (BI-RADS). Jack-knife alternative free-response receiver-operating characteristic (JAFROC), which allows diagnostic performance estimation using single lesion as a statistical unit in a cancer-only population, was used. Sensitivity and positive predictive value (PPV) were compared using the McNemar and Fisher-exact tests. The JAFROC figures of merit (FOMs) was lower in DBT plus mammography (0.937) than MRI plus mammography (0.978, P = 0.0006) but higher than mammography alone (0.900, P = 0.0013). The sensitivity was lower in DBT plus mammography (88.2 %) than MRI plus mammography (97.8 %) but higher than mammography alone (78.3 %, both P < 0.0001). The PPV was significantly higher in DBT plus mammography (93.3 %) than MRI plus mammography (89.6 %, P = 0.0282). DBT provided lower diagnostic performance than MRI as an adjunctive imaging to mammography. However, DBT had higher diagnostic performance than mammography and higher PPV than MRI. (orig.)

  8. Methodology, models and algorithms in thermographic diagnostics

    CERN Document Server

    Živčák, Jozef; Madarász, Ladislav; Rudas, Imre J

    2013-01-01

    This book presents  the methodology and techniques of  thermographic applications with focus primarily on medical thermography implemented for parametrizing the diagnostics of the human body. The first part of the book describes the basics of infrared thermography, the possibilities of thermographic diagnostics and the physical nature of thermography. The second half includes tools of intelligent engineering applied for the solving of selected applications and projects. Thermographic diagnostics was applied to problematics of paraplegia and tetraplegia and carpal tunnel syndrome (CTS). The results of the research activities were created with the cooperation of the four projects within the Ministry of Education, Science, Research and Sport of the Slovak Republic entitled Digital control of complex systems with two degrees of freedom, Progressive methods of education in the area of control and modeling of complex object oriented systems on aircraft turbocompressor engines, Center for research of control of te...

  9. MATLAB simulation for an experimental setup of digital feedback control

    International Nuclear Information System (INIS)

    Zheng Lifang; Liu Songqiang

    2005-01-01

    This paper describes the digital feedback simulation using MATLAB for an experimental accelerator control setup. By analyzing the plant characteristic in time-domain and frequency-domain, a guideline for design of digital filter and PID controller is derived. (authors)

  10. A wireless reflectance pulse oximeter with digital baseline control for unfiltered photoplethysmograms.

    Science.gov (United States)

    Li, Kejia; Warren, Steve

    2012-06-01

    Pulse oximeters are central to the move toward wearable health monitoring devices and medical electronics either hosted by, e.g., smart phones or physically embedded in their design. This paper presents a small, low-cost pulse oximeter design appropriate for wearable and surface-based applications that also produces quality, unfiltered photo-plethysmograms (PPGs) ideal for emerging diagnostic algorithms. The design's "filter-free" embodiment, which employs only digital baseline subtraction as a signal compensation mechanism, distinguishes it from conventional pulse oximeters that incorporate filters for signal extraction and noise reduction. This results in high-fidelity PPGs with thousands of peak-to-peak digitization levels that are sampled at 240 Hz to avoid noise aliasing. Electronic feedback controls make these PPGs more resilient in the face of environmental changes (e.g., the device can operate in full room light), and data stream in real time across either a ZigBee wireless link or a wired USB connection to a host. On-board flash memory is available for store-and-forward applications. This sensor has demonstrated an ability to gather high-integrity data at fingertip, wrist, earlobe, palm, and temple locations from a group of 48 subjects (20 to 64 years old).

  11. Safety of Diagnostic Cerebral and Spinal Digital Subtraction Angiography in a Developing Country: A Single-Center Experience.

    Science.gov (United States)

    Bashir, Qasim; Ishfaq, Asim; Baig, Ammad Anwar

    2018-02-01

    Digital subtraction angiography (DSA) remains the gold standard imaging modality for cerebrovascular disorders. In contrast to developed countries, the safety of the procedure is not extensively reported from the developing countries. Herein, we present a retrospective analysis of the basic technique, indications, and outcomes in 286 patients undergoing diagnostic cerebral and spinal angiography in a developing country, Pakistan. A retrospective review of patient demographics, procedural technique and complication rates of 286 consecutive patients undergoing the diagnostic cerebral/spinal angiography procedure at one institution from May 2013 to December 2015 was performed. Neurological, systemic, or local complications occurring within and after 24 h of the procedure were recorded. Mean age reported for all patients was 49.7 years. Of all the 286 cases, 175 were male (61.2%) and the rest female (111, 38.8%). Cerebral DSA was performed in 279 cases (97.6%), with 7 cases of spinal DSA (2.4%). Subarachnoid hemorrhage was the most common indication for DSA accounting for 88 cases (30.8%), closely followed by stroke (26.6%) and arteriosclerotic vascular disease (23.1%). No intra- or post-procedural neurological complications of any severity were seen in any of the 286 cases. One case of asymptomatic aortic dissection was reported (0.3%) in the entire cohort of patient population. Diagnostic cerebral/spinal digital subtraction angiography was found to be safe in Pakistan, with complication rates at par with and comparable to those reported in the developed world.

  12. Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications

    International Nuclear Information System (INIS)

    Clauser, Paola; Nagl, Georg; Helbich, Thomas H.; Pinker-Domenig, Katja; Weber, Michael; Kapetas, Panagiotis; Bernathova, Maria; Baltzer, Pascal A.T.

    2016-01-01

    Highlights: • Wide scan-angle DBT alone shows a high detection rate for microcalcifications. • DBT and FFDM can characterize microcalcifications at a comparable level. • Characterization is influenced by reader and by lesion type (benign vs malignant). • DBT might be used as a stand-alone technique for the assessment of microcalcifications. - Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients’ history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions’ characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

  13. Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications

    Energy Technology Data Exchange (ETDEWEB)

    Clauser, Paola, E-mail: paola.clauser@meduniwien.ac.at [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Nagl, Georg [Department for Radiology and Interventional Radiology, Landesklinikum Horn, Spitalgasse 10, 3580 Horn (Austria); Helbich, Thomas H., E-mail: thomas.helbich@meduniwien.ac.at [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Pinker-Domenig, Katja [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Weber, Michael [Department of Biomedical Imaging and Image-Guided Therapy, Division of General and Pediatric Radiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Kapetas, Panagiotis; Bernathova, Maria; Baltzer, Pascal A.T. [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)

    2016-12-15

    Highlights: • Wide scan-angle DBT alone shows a high detection rate for microcalcifications. • DBT and FFDM can characterize microcalcifications at a comparable level. • Characterization is influenced by reader and by lesion type (benign vs malignant). • DBT might be used as a stand-alone technique for the assessment of microcalcifications. - Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients’ history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions’ characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

  14. Smartphone Addiction and School Life Adjustment Among High School Students: The Mediating Effect of Self-Control.

    Science.gov (United States)

    Heo, YoungJin; Lee, Kyunghee

    2018-05-08

    Previous studies have reported associations among smartphone addiction, school adjustment, and self-control. However, the causal relationship between smartphone addiction and school adjustment has not been clearly demonstrated. The current study examined the association between smartphone addiction and school adjustment and investigated the mediating effect of self-control in this association. A total of 790 students from five high schools in Daegu City, South Korea, were asked to provide demographic information and complete a self-diagnostic smartphone addiction scale and validated Korean version of a self-control scale. Among at-risk students, self-control did not mediate the relation between smartphone addiction and school adjustment; among those not at risk, there was a partial mediating effect. To improve school adjustment among high school students, prevention of smartphone addiction seems important. Smartphone addiction could be managed by strengthening self-control to promote healthy use of smartphones. The current results can serve as groundwork for the development of programs to improve school adjustment among high school students. [Journal of Psychosocial Nursing and Mental Health Services, xx(x), xx-xx.]. Copyright 2018, SLACK Incorporated.

  15. The development of ZPRL digital control system

    International Nuclear Information System (INIS)

    Hsu, Jin-Den; Yang, Sheau-Yieh; Shieh, Der-Jhy.

    1992-01-01

    Zero Power Reactor at Lung-Tan (ZPRL) is a small open-pool type research reactor located at Lung-Tan, Taiwan. The reactor achieved its first criticality in 1971. An analog control system has been used for almost over 20 years and the power regulating function is found gradually out of order. Therefore, we decided to develop a digital control system to replace the existing analog one. A prototype system has been developed and under on-line test now. The proposed ZPRL digital control system consists of three personal computers. These computers are used as (1) operator console, (2) data acquisition and control system, and (3) auxiliary and backup system. The operator console contains all the man-machine interface functions in the form of graphic display. The data acquisition and control system converts the analog signals into digital ones and feeds to the other two computers. The auxiliary and backup system normally emulates a strip chart recorder for the linear and logarithmic neutron powers and also acts as a transient recorder to keep the trace of the operating conditions on demand or when the reactor scrams. On-line test shows that the system does assure a satisfactory performance. It is not only as good as the analog system but also has the advantages of flexibility, testibility, and a user friendly man-machine interface. (author)

  16. Remote Control of TJ-II Diagnostics

    International Nuclear Information System (INIS)

    Lopez Sanchez, A.; Vega, J.; Montoro, A.; Encabo, J.

    2001-01-01

    The present paper is about the design and development of ten remote control diagnostic systems used in the study of plasma fusion in the TJ-II device installed at CIEMAT. This development goes from the definition of sensors and devices necessary in carrying out these remote controls, to its assembly, wiring, development of electronic circuits inserted between sensors and PLC, development of programs for these PLC, connections and administration of the real time automation network, and later development of the necessary programs via the appropriate software tools for web access through a navigator to a specific web page, allowing visual and real time access over the auxiliary systems that make up all the diagnostics. (Author)

  17. Digital breast tomosynthesis plus synthesised images versus standard full-field digital mammography in population-based screening (TOSYMA): protocol of a randomised controlled trial.

    Science.gov (United States)

    Weigel, Stefanie; Gerss, Joachim; Hense, Hans-Werner; Krischke, Miriam; Sommer, Alexander; Czwoydzinski, Jörg; Lenzen, Horst; Kerschke, Laura; Spieker, Karin; Dickmaenken, Stefanie; Baier, Sonja; Urban, Marc; Hecht, Gerold; Heidinger, Oliver; Kieschke, Joachim; Heindel, Walter

    2018-05-14

    Development of digital breast tomosynthesis (DBT) provides a technology that generates three-dimensional data sets, thus reducing the pitfalls of overlapping breast tissue. Observational studies suggest that the combination of two-dimensional (2D) digital mammography and DBT increases diagnostic accuracy. However, because of duplicate exposure, this comes at the cost of an augmented radiation dose. This undesired adverse impact can be avoided by using synthesised 2D images reconstructed from the DBT data (s2D).We designed a diagnostic superiority trial on a high level of evidence with the aim of providing a comparison of screening efficacy parameters resulting from DBT+s2D versus the current screening standard 2D full-field digital mammography (FFDM) in a multicentre and multivendor setting on the basis of the quality-controlled, population-based, biennial mammography screening programme in Germany. 80 000 women in the eligible age 50-69 years attending the routine mammography screening programme and willing to participate in the TOSYMA trial will be assigned by 1:1 randomisation to either the intervention arm (DBT+s2D) or the control arm (FFDM) during a 12-month recruitment period in screening units of North Rhine-Westphalia and Lower Saxony. State cancer registries will provide the follow-up of interval cancers.Primary endpoints are the detection rate of invasive breast cancers at screening examination and the cumulative incidence of interval cancers in the 2 years after a negative examination. Secondary endpoints are the detection rate of ductal carcinoma in situ and of tumour size T1, the recall rate for assessment, the positive predictive value of recall and the cumulative 12-month incidence of interval cancers. An adaptive statistical design with one interim analysis provides the option to modify the design. This protocol has been approved by the local medical ethical committee (2016-132-f-S). Results will be submitted to international peer

  18. Formulation of a strategy for monitoring control integrity in critical digital control systems

    Science.gov (United States)

    Belcastro, Celeste M.; Fischl, Robert; Kam, Moshe

    1991-01-01

    Advanced aircraft will require flight critical computer systems for stability augmentation as well as guidance and control that must perform reliably in adverse, as well as nominal, operating environments. Digital system upset is a functional error mode that can occur in electromagnetically harsh environments, involves no component damage, can occur simultaneously in all channels of a redundant control computer, and is software dependent. A strategy is presented for dynamic upset detection to be used in the evaluation of critical digital controllers during the design and/or validation phases of development. Critical controllers must be able to be used in adverse environments that result from disturbances caused by an electromagnetic source such as lightning, high intensity radiated field (HIRF), and nuclear electromagnetic pulses (NEMP). The upset detection strategy presented provides dynamic monitoring of a given control computer for degraded functional integrity that can result from redundancy management errors and control command calculation error that could occur in an electromagnetically harsh operating environment. The use is discussed of Kalman filtering, data fusion, and decision theory in monitoring a given digital controller for control calculation errors, redundancy management errors, and control effectiveness.

  19. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  20. Self Diagnostic Adhesive for Bonded Joints in Aircraft Structures

    Science.gov (United States)

    2016-10-04

    validated under the fatigue /dynamic loading condition. 3) Both SEM (Spectral Element Modeling) and FEM (Finite Element Modeling) simulation of the...between input voltage and output charge provide the real and imaginary impedance as illustrated in Figure 3. (a) Adhesive + plate (ΩS) PZT (ΩP...3 m m 0.45mm Adhesive 3.18mm dia. PZT disc (0.25mm thick) 8 Self-Diagnostic Adhesive for Bonded Joints in Aircraft Structures

  1. Effects of digital Cognitive Behavioural Therapy for Insomnia on cognitive function: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Kyle, Simon D; Hurry, Madeleine E D; Emsley, Richard; Luik, Annemarie I; Omlin, Ximena; Spiegelhalder, Kai; Espie, Colin A; Sexton, Claire E

    2017-06-17

    The daytime effects of insomnia pose a significant burden to patients and drive treatment seeking. In addition to subjective deficits, meta-analytic data show that patients experience reliable objective impairments across several cognitive domains. While Cognitive Behavioural Therapy for Insomnia (CBT-I) is an effective and scalable treatment, we know little about its impact upon cognitive function. Trials of CBT-I have typically used proxy measures for cognitive functioning, such as fatigue or work performance scales, and no study has assessed self-reported impairment in cognitive function as a primary outcome. Moreover, only a small number of studies have assessed objective cognitive performance, pre-to-post CBT-I, with mixed results. This study specifically aims to (1) investigate the impact of CBT-I on cognitive functioning, assessed through both self-reported impairment and objective performance measures, and (2) examine whether change in sleep mediates this impact. We propose a randomised controlled trial of 404 community participants meeting criteria for Insomnia Disorder. In the DISCO trial (D efining the I mpact of improved S leep on CO gnitive function (DISCO)) participants will be randomised to digital automated CBT-I delivered by a web and/or mobile platform (in addition to treatment as usual (TAU)) or to a wait-list control (in addition to TAU). Online assessments will take place at 0 (baseline), 10 (post-treatment), and 24 (follow-up) weeks. At week 25, all participants allocated to the wait-list group will be offered digital CBT-I, at which point the controlled element of the trial will be complete. The primary outcome is self-reported cognitive impairment at post-treatment (10 weeks). Secondary outcomes include objective cognitive performance, insomnia severity, sleepiness, fatigue, and self-reported cognitive failures and emotional distress. All main analyses will be carried out on completion of follow-up assessments and will be based on the

  2. Digital Fractional Order Controllers Realized by PIC Microprocessor: Experimental Results

    OpenAIRE

    Petras, I.; Grega, S.; Dorcak, L.

    2003-01-01

    This paper deals with the fractional-order controllers and their possible hardware realization based on PIC microprocessor and numerical algorithm coded in PIC Basic. The mathematical description of the digital fractional -order controllers and approximation in the discrete domain are presented. An example of realization of the particular case of digital fractional-order PID controller is shown and described.

  3. Optimum phase shift in the self-oscillating loop for piezoelectric transformer-based power converters

    DEFF Research Database (Denmark)

    Ekhtiari, Marzieh; Zsurzsan, Tiberiu-Gabriel; Andersen, Michael A. E.

    2017-01-01

    A new method is implemented in designing of self-oscillating loop for driving piezoelectric transformers. The implemented method is based on combining both analog and digital control systems. Digitally controlled time delay through the self-oscillating loop results in very precise frequency control...... and ensures optimum operation of the piezoelectric transformer in terms of gain and efficiency. Time delay is implemented digitally for the first time through a 16 bit digital-to-analog converter in the self-oscillating loop. The new design of the delay circuit provides 45 ps time resolution, enabling fine......-grained control of phase in the self-oscillating loop. This allows the control loop to dynamically follow frequency changes of the transformer in each resonant cycle. Ultimately, by selecting the optimum phase shift, maximum efficiency under the load and temperature condition is achievable....

  4. Digital tomosynthesis of the breast

    International Nuclear Information System (INIS)

    Barkhausen, Joerg; Rody, Achim; Schaefer, Fritz K.W.

    2015-01-01

    The digital tomosynthesis applies the digital image analysis and 3D technology for improves diagnostic uses. The text book on the digital tomosynthesis of the breast covers the following issues: technique of tomosynthesis, clinical significance of digital breast tomosynthesis, innovations and future developments, case studies.

  5. Reference to Self and Other in the Digital Public Sphere: The Case of Political Blogs.

    Science.gov (United States)

    De Cock, Barbara; González Arias, Cristian

    2018-04-01

    In this paper, we analyze how a political blog author (Spanish Alejo Vidal-Quadras) establishes the reference to self and other in his blog entries. We furthermore look into how the commentators to this blog react and establish reference to self and other in the digital public sphere. More concretely, we show that they not only take up the references established by the main blog author but also create new references. These allow, on the one hand, for profiling themselves as part of a group and, on the other hand, identifying their interlocutor among the variety of possible interlocutors in the digital public sphere. By addressing different interlocutors, the commentators turn the comments section into a dialogic space, a dimension that is lacking in the main blog entries. However, the fact that they almost invariably identify interlocutors other than Vidal-Quadras but address Vidal-Quadras without explicitly identifying him, shows that Vidal-Quadras remains the main ratified interlocutor in view of his ownership of the blog. This paper shows then how participants in the digital public sphere create a complex relationship of self and other reference in political blogs.

  6. Life-critical digital flight control systems

    Science.gov (United States)

    Mcwha, James

    1990-01-01

    Digital autopilot systems were first used on commercial airplanes in the late 1970s. The A-320 airplane was the first air transport airplane with a fly-by-wire primary flight control system. On the 767-X (777) airplane Boeing will install all fly-by-wire flight controls. Activities related to safety, industry status and program phases are discussed.

  7. Digital Signal Processing in Beam Instrumentation Latest Trends and Typical Applications

    CERN Document Server

    Angoletta, Maria Elena

    2003-01-01

    The last decade has seen major improvements in digital hardware, algortithms and software, which have trickled down to the Beam Instrumentation (BI) area. An advantageous transition is taking place towards systems with an ever-stronger digital presence. Digital systems are assembled by means of a rather small number of basic building blocks, with improved speed, precision, signal-to-noise ratio, dynamic range, flexibility, and accompanied by a range of powerful and user-friendly development tools. The paper reviews current digital BI trends, including using Digital Signal Processors, Field Programmable Gate Arrays, Digital Receivers and General Purpose Processors as well as some useful processing algorithms. Selected digital applications are illustrated on control/feedback and beam diagnostics.

  8. A scalable, self-analyzing digital locking system for use on quantum optics experiments.

    Science.gov (United States)

    Sparkes, B M; Chrzanowski, H M; Parrain, D P; Buchler, B C; Lam, P K; Symul, T

    2011-07-01

    Digital control of optics experiments has many advantages over analog control systems, specifically in terms of the scalability, cost, flexibility, and the integration of system information into one location. We present a digital control system, freely available for download online, specifically designed for quantum optics experiments that allows for automatic and sequential re-locking of optical components. We show how the inbuilt locking analysis tools, including a white-noise network analyzer, can be used to help optimize individual locks, and verify the long term stability of the digital system. Finally, we present an example of the benefits of digital locking for quantum optics by applying the code to a specific experiment used to characterize optical Schrödinger cat states.

  9. PathEdEx – Uncovering high-explanatory visual diagnostics heuristics using digital pathology and multiscale gaze data

    Directory of Open Access Journals (Sweden)

    Dmitriy Shin

    2017-01-01

    Full Text Available Background: Visual heuristics of pathology diagnosis is a largely unexplored area where reported studies only provided a qualitative insight into the subject. Uncovering and quantifying pathology visual and nonvisual diagnostic patterns have great potential to improve clinical outcomes and avoid diagnostic pitfalls. Methods: Here, we present PathEdEx, an informatics computational framework that incorporates whole-slide digital pathology imaging with multiscale gaze-tracking technology to create web-based interactive pathology educational atlases and to datamine visual and nonvisual diagnostic heuristics. Results: We demonstrate the capabilities of PathEdEx for mining visual and nonvisual diagnostic heuristics using the first PathEdEx volume of a hematopathology atlas. We conducted a quantitative study on the time dynamics of zooming and panning operations utilized by experts and novices to come to the correct diagnosis. We then performed association rule mining to determine sets of diagnostic factors that consistently result in a correct diagnosis, and studied differences in diagnostic strategies across different levels of pathology expertise using Markov chain (MC modeling and MC Monte Carlo simulations. To perform these studies, we translated raw gaze points to high-explanatory semantic labels that represent pathology diagnostic clues. Therefore, the outcome of these studies is readily transformed into narrative descriptors for direct use in pathology education and practice. Conclusion: PathEdEx framework can be used to capture best practices of pathology visual and nonvisual diagnostic heuristics that can be passed over to the next generation of pathologists and have potential to streamline implementation of precision diagnostics in precision medicine settings.

  10. Possible radiation dose reduction by using digital X-ray equipment

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.; Prikazska, M.

    2001-01-01

    The radiation load of population all over the world from medical examinations clearly demonstrates the importance of the introduction of the quality assurance and quality control programmes into the activities of radiology departments. The basic aim of quality assurance program is to ensure that the radiation dose is kept as low as reasonably practicable while still providing an adequate image quality. As many other fields, the rapid development of techniques brought change-over from the conventional analogue technique to the digital technique. In this process, the conventional X-ray film is being abandoned and images are being viewed on either laser film or monitor. The main advantages of using digital equipment lay in improved image quality and diagnostic accuracy through digital image processing, reduction in patients exposure, cost reduction by reduction of the film usage, more efficient storage and retrieval of radiographic images through picture archiving. Several studies that have been conducted for comparison of various diagnostic examinations show , that there is potential for dose saving in the digital image intensifier technique. The aim of this study was to compare measured values of dose-area product for colon investigations using different X-ray equipment types, two digital and two analogue. Our material consisted of 169 randomly selected patients, 115 of them were examined with digital equipment and 54 patients with the analogue equipment. The obtained results have confirmed the dose reduction and increase of diagnostic accuracy when using the digital equipment, with the added benefit of a good image quality. (authors)

  11. Non-linear hybrid control oriented modelling of a digital displacement machine

    DEFF Research Database (Denmark)

    Pedersen, Niels Henrik; Johansen, Per; Andersen, Torben O.

    2017-01-01

    Proper feedback control of digital fluid power machines (Pressure, flow, torque or speed control) requires a control oriented model, from where the system dynamics can be analyzed, stability can be proven and design criteria can be specified. The development of control oriented models for hydraulic...... Digital Displacement Machines (DDM) is complicated due to non-smooth machine behavior, where the dynamics comprises both analog, digital and non-linear elements. For a full stroke operated DDM the power throughput is altered in discrete levels based on the ratio of activated pressure chambers....... In this paper, a control oriented hybrid model is established, which combines the continuous non-linear pressure chamber dynamics and the discrete shaft position dependent activation of the pressure chambers. The hybrid machine model is further extended to describe the dynamics of a Digital Fluid Power...

  12. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  13. Digital control of research reactors

    International Nuclear Information System (INIS)

    Crump, J.C. III.; Richards, W.J.; Heidel, C.C.

    1991-01-01

    Research reactors provide an important service for the nuclear industry. Developments and innovations used for research reactors can be later applied to larger power reactors. Their relatively inexpensive cost allows research reactors to be an excellent testing ground for the reactors of tomorrow. One area of current interest is digital control of research reactor systems. Digital control systems offer the benefits of implementation and superior system response over their analog counterparts. At McClellan Air Force Base in Sacramento, California, the Stationary Neutron Radiography System (SNRS) uses a 1,000-kW TRIGA reactor for neutron radiography and other nuclear research missions. The neutron radiography beams generated by the reactor are used to detect corrosion in aircraft structures. While the use of the reactor to inspect intact F-111 wings is in itself noteworthy, there is another area in which the facility has applied new technology: the instrumentation and control system (ICS). The ICS developed by General Atomics (GA) contains several new and significant items: (a) the ability to servocontrol on three rods, (b) the ability to produce a square wave, and (c) the use of a software configurator to tune parameters affected by the actual reactor core dynamics. These items will probably be present in most, if not all, future research reactors. They were developed with increased control and overall usefulness of the reactor in mind

  14. Only one small sin: How self-construal affects self-control.

    Science.gov (United States)

    Steinmetz, Janina; Mussweiler, Thomas

    2017-12-01

    Past research has shown that self-construal can influence self-control by reducing interdependent people's impulsivity in the presence of peers. We broaden these findings by examining the hypothesis that an interdependent (vs. independent) self-construal fosters self-control even in the absence of peers and for non-impulsive decisions. We further explore whether this effect could be mediated by the more interrelated (vs. isolated) processing style of interdependent (vs. independent) people. Such an interrelated (vs. isolated) processing style of temptations makes the impact of a single temptation more salient and can thereby increase self-control. Study 1 demonstrated that more interdependent participants show more self-control behaviour by refraining from chocolate consumption to secure a monetary benefit. Studies 2a and 2b highlighted a link between self-construal and trait self-control via the processing of temptations. Study 3 suggested that an interrelated (vs. isolated) perspective on temptations could mediate the effect of (primed) self-construal on self-control. Taken together, self-construal shapes self-control across various decision contexts. © 2017 The British Psychological Society.

  15. Effects of Different Compression Techniques on Diagnostic Accuracies of Breast Masses on Digitized Mammograms

    International Nuclear Information System (INIS)

    Zhigang Liang; Xiangying Du; Jiabin Liu; Yanhui Yang; Dongdong Rong; Xinyu Y ao; Kuncheng Li

    2008-01-01

    Background: The JPEG 2000 compression technique has recently been introduced into the medical imaging field. It is critical to understand the effects of this technique on the detection of breast masses on digitized images by human observers. Purpose: To evaluate whether lossless and lossy techniques affect the diagnostic results of malignant and benign breast masses on digitized mammograms. Material and Methods: A total of 90 screen-film mammograms including craniocaudal and lateral views obtained from 45 patients were selected by two non-observing radiologists. Of these, 22 cases were benign lesions and 23 cases were malignant. The mammographic films were digitized by a laser film digitizer, and compressed to three levels (lossless and lossy 20:1 and 40:1) using the JPEG 2000 wavelet-based image compression algorithm. Four radiologists with 10-12 years' experience in mammography interpreted the original and compressed images. The time interval was 3 weeks for each reading session. A five-point malignancy scale was used, with a score of 1 corresponding to definitely not a malignant mass, a score of 2 referring to not a malignant mass, a score of 3 meaning possibly a malignant mass, a score of 4 being probably a malignant mass, and a score of 5 interpreted as definitely a malignant mass. The radiologists' performance was evaluated using receiver operating characteristic analysis. Results: The average Az values for all radiologists decreased from 0.8933 for the original uncompressed images to 0.8299 for the images compressed at 40:1. This difference was not statistically significant. The detection accuracy of the original images was better than that of the compressed images, and the Az values decreased with increasing compression ratio. Conclusion: Digitized mammograms compressed at 40:1 could be used to substitute original images in the diagnosis of breast cancer

  16. Reliability of self-reported diagnostic radiation history in BRCA1/2 mutation carriers

    International Nuclear Information System (INIS)

    Pijpe, Anouk; Manders, Peggy; Mulder, Renee L.; Leeuwen, Flora E. van; Rookus, Matti A.

    2010-01-01

    We assessed reliability of self-reported diagnostic radiation history in BRCA1/2 mutation carriers with and without breast cancer. Within the frame-work of the HEBON study, 401 BRCA1/2 mutation carriers completed a baseline (1999-2004) and a follow-up questionnaire (2006-2007). Test-retest reliability of self-reported exposure to chest X-rays, fluoroscopies and mammograms was assessed for the entire study population and by case status. Overall proportion agreement on reporting ever/never exposure was good (> 75%), while the corresponding kappa coefficients were between 0.40 and 0.75, indicating at least moderate reliability beyond chance. Reliability of number of exposures was also good (> 75%). Proportion agreement on reporting age at first mammogram was low (40%) for exact consistency and moderate (60%) for consistency ± 1 year. Reliability of age at first mammogram was higher for cases than for unaffected carriers (P < 0.001) but this difference disappeared when excluding diagnostic mammograms (P = 0.60). In unaffected carriers proportion agreement on age at last mammogram was 50%. In general, the direction of disagreement on all items was equally distributed. More consistent reporting was mainly determined by a younger age at questionnaire completion. In conclusion, inconsistent self-report of diagnostic radiation by BRCA1/2 mutation carriers was mainly non-differential by disease status.

  17. 162.5 MHz digital low-level radio frequency control monitoring system design and implementation

    International Nuclear Information System (INIS)

    Zhang Ruifeng; Wang Xianwu; Xu Zhe; Yi Xiaoping

    2014-01-01

    162.5 MHz high-frequency low-level control system self-developed by Institute of Modern Physics for ADS project took digital technology. All parameters' reading and writing, including loop parameter setting, open and close-loop operation, and condition monitoring, were achieved through the monitoring system. The system used lightweight client-server working mode that client running in the PC sent command data, server running on high-frequency digital low level system responded instructions to complete parameter monitoring and control. The system consisted of three parts. Firstly, server hardware system was constructed based on Atera Stratix Ⅲ family of field-programmable gate array (FPGA) development board. Secondly, the server software system was designed based on Micro C/OS Ⅱ real-time operating systems and lightweight TCP/IP protocol stack, and finally a client PC program was designed based on MFC. After a long test, it was indicated that the monitoring system works properly and stably. TCP sends and receives throughput reached 11.931038 Mbps and 8.117624 Mbps. (authors)

  18. Combating stress risks with the job stress self diagnostic method: paper XV World Congress of Sociology 2002

    OpenAIRE

    Oeij, P.R.A.

    2002-01-01

    In this paper of the World Congress of Sociology 2002 of ISA (International Sociological Association), the content and uses of the Job Stress Self Diagnostic Method (JSSDM) are described. The JSSDM aim is (a) to diagnose work processes to determine the presence of conditions for control problems and stress risks, and (b) to develop solutions to combat stress risks on organisational level. The method is based on three theories of job and organisation design and on the insight to combine viewpo...

  19. Digital angiography in pulmonary embolism

    International Nuclear Information System (INIS)

    Bjoerk, L.

    1986-01-01

    Pulmonary digital subtraction angiography was diagnostic in 98.3% of patients with possible acute pulmonary embolism. The procedure was well tolerated even in severely ill patients. A large image intensifier made simultaneous imaging of both lungs possible reducing the number of contrast injections necessary. Small volumes of low iso-osmolar concentration of modern contrast media were used. There was no need for catherization of the pulmonary artery. Theoretical considerations and our limited experience indicate that this will reduce the number of complications compared with conventional pulmonary angiography. The procedure is rapidly performed and the diagnostic accuracy high. This makes digital subtraction angiography cost effective. Digital pulmonary angiography can be recommended as the primary diagnostic method in most patients with possible pulmonary embolism. (orig.)

  20. Migration of Older to New Digital Control Systems in Nuclear Power Plant Main Control Rooms

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, Casey Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey Clark [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-04-01

    The United States (U.S.) Department of Energy (DOE) Office of Nuclear Energy (NE) has the primary mission to advance nuclear power by resolving socio-technical issues through research and development (R&D). One DOE-NE activity supporting this mission is the Light Water Reactor Sustainability (LWRS) program. LWRS has the overall objective to sustain the operation of existing commercial nuclear power plants (NPPs) through conducting R&D across multiple “pathways,” or R&D focus areas. The Advanced Instrumentation, Information, and Control (II&C) Systems Technologies pathway conducts targeted R&D to address aging and reliability concerns with the legacy instrumentation and control (I&C) and related information systems in operating U.S. NPPs. This work involves (1) ensuring that legacy analog II&C systems are not life-limiting issues for the LWR fleet, and (2) implementing digital II&C technology in a manner that enables broad innovation and business improvement in the NPP operating model. Under the LWRS Advanced II&C pathway, Human Factors experts at Idaho National Laboratory (INL) have been conducting R&D in support of NPP main control room (MCR) modernization activities. Work in prior years has focused on migrating analog I&C systems to new digital I&C systems (). In fiscal year 2016 (FY16), one new focus area for this research is migrating older digital I&C systems to new and advanced digital I&C systems. This report summarizes a plan for conducting a digital-to-digital migration of a legacy digital I&C system to a new digital I&C system in support of control room modernization activities.

  1. Migration of Older to New Digital Control Systems in Nuclear Power Plant Main Control Rooms

    International Nuclear Information System (INIS)

    Kovesdi, Casey Robert; Joe, Jeffrey Clark

    2016-01-01

    The United States (U.S.) Department of Energy (DOE) Office of Nuclear Energy (NE) has the primary mission to advance nuclear power by resolving socio-technical issues through research and development (R&D). One DOE-NE activity supporting this mission is the Light Water Reactor Sustainability (LWRS) program. LWRS has the overall objective to sustain the operation of existing commercial nuclear power plants (NPPs) through conducting R&D across multiple ''pathways,'' or R&D focus areas. The Advanced Instrumentation, Information, and Control (II&C) Systems Technologies pathway conducts targeted R&D to address aging and reliability concerns with the legacy instrumentation and control (I&C) and related information systems in operating U.S. NPPs. This work involves (1) ensuring that legacy analog II&C systems are not life-limiting issues for the LWR fleet, and (2) implementing digital II&C technology in a manner that enables broad innovation and business improvement in the NPP operating model. Under the LWRS Advanced II&C pathway, Human Factors experts at Idaho National Laboratory (INL) have been conducting R&D in support of NPP main control room (MCR) modernization activities. Work in prior years has focused on migrating analog I&C systems to new digital I&C systems (). In fiscal year 2016 (FY16), one new focus area for this research is migrating older digital I&C systems to new and advanced digital I&C systems. This report summarizes a plan for conducting a digital-to-digital migration of a legacy digital I&C system to a new digital I&C system in support of control room modernization activities.

  2. Digital control of wind tunnel magnetic suspension and balance systems

    Science.gov (United States)

    Britcher, Colin P.; Goodyer, Michael J.; Eskins, Jonathan; Parker, David; Halford, Robert J.

    1987-01-01

    Digital controllers are being developed for wind tunnel magnetic suspension and balance systems, which in turn permit wind tunnel testing of aircraft models free from support interference. Hardware and software features of two existing digital control systems are reviewed. Some aspects of model position sensing and system calibration are also discussed.

  3. Modernization of control system using the digital control system

    International Nuclear Information System (INIS)

    Carrasco, J. A.; Fernandez, L.; Jimenez, A.

    2002-01-01

    Nowadays, all plant automation tendencies are based on the use of Digital Control System. In big industrial plants the control systems employed are Distributed Control Systems (DCS). The addition of these systems in nuclear power plants,implies an important adaptation process, because most of them were installed using analog control systems. This paper presents the objectives and the first results obtained, in a modernization project, focused in obtaining an engineering platform for making test and analysis of changes prior to their implementation in a nuclear plant. Modernization, Upgrade, DCS, Automation, Simulation, Training. (Author)

  4. Effects of a 12-Week Digital Care Program for Chronic Knee Pain on Pain, Mobility, and Surgery Risk: Randomized Controlled Trial.

    Science.gov (United States)

    Mecklenburg, Gabriel; Smittenaar, Peter; Erhart-Hledik, Jennifer C; Perez, Daniel A; Hunter, Simon

    2018-04-25

    Chronic knee pain, most commonly caused by knee osteoarthritis, is a prevalent condition which in most cases can be effectively treated through conservative, non-surgical care involving exercise therapy, education, psychosocial support, and weight loss. However, most people living with chronic knee pain do not receive adequate care, leading to unnecessary use of opiates and surgical procedures. Assess the efficacy of a remotely delivered digital care program for chronic knee pain. We enrolled 162 participants into a randomized controlled trial between January and March 2017. Participants were recruited from participating employers using questionnaires for self-assessment of their knee pain, and randomized into treatment (n=101) and control (n=61) groups. Participants in the treatment group were enrolled in the Hinge Health digital care program for chronic knee pain. This is a remotely delivered, home-based 12-week intervention that includes sensor-guided exercise therapy, education, cognitive behavioral therapy, weight loss, and psychosocial support through a personal coach and team-based interactions. The control group received three education pieces regarding self-care for chronic knee pain. Both groups had access to treatment-as-usual. The primary outcome was the Knee Injury and Osteoarthritis Outcome Score (KOOS) Pain subscale and KOOS Physical Function Shortform (KOOS-PS). Secondary outcomes were visual analog scales (VAS) for pain and stiffness respectively, surgery intent, and self-reported understanding of the condition and treatment options. Outcome measures were analyzed by intention to treat (excluding 7 control participants who received the digital care program due to administrative error) and per protocol. In an intent-to-treat analysis the digital care program group had a significantly greater reduction in KOOS Pain compared to the control group at the end of the program (greater reduction of 7.7, 95% CI 3.0 to 12.3, P=.002), as well as a

  5. Design of digital logic control for accelerator magnet power supply

    International Nuclear Information System (INIS)

    Long Fengli; Hu Wei; Cheng Jian

    2008-01-01

    For the accelerator magnet power supply, usually the Programmable Logic Controller (PLC) is used to server as the controller for logic protection and control. Along with the development of modern accelerator technology, it is a trend to use fully-digital control to the magnet power supply. It is possible to integrate the logic control part into the digital control component of the power supply, for example, the Field Programmable Gate Array (FPGA). The paper introduces to different methods which are designed for the logic protection and control for accelerator magnet power supplies with the FPGA as the control component. (authors)

  6. Superior Self-Paced Memorization of Digits in Spite of a Normal Digit Span: The Structure of a Memorist's Skill

    Science.gov (United States)

    Hu, Yi; Ericsson, K. Anders; Yang, Dan; Lu, Chao

    2009-01-01

    Over the last century many individuals with exceptional memory have been studied and tested in the laboratory. This article studies Chao Lu, who set a Guinness World Record by memorizing 67,890 decimals of pi. Chao Lu's superior self-paced memorization of digits is shown through analyses of study times and verbal reports to be mediated by mnemonic…

  7. The use of digital images in pathology.

    Science.gov (United States)

    Furness, P N

    1997-11-01

    Digital images are routinely used by the publishing industry, but most diagnostic pathologists are unfamiliar with the technology and its possibilities. This review aims to explain the basic principles of digital image acquisition, storage, manipulation and use, and the possibilities provided not only in research, but also in teaching and in routine diagnostic pathology. Images of natural objects are usually expressed digitally as 'bitmaps'--rectilinear arrays of small dots. The size of each dot can vary, but so can its information content in terms, for example, of colour, greyscale or opacity. Various file formats and compression algorithms are available. Video cameras connected to microscopes are familiar to most pathologists; video images can be converted directly to a digital form by a suitably equipped computer. Digital cameras and scanners are alternative acquisition tools of relevance to pathologists. Once acquired, a digital image can easily be subjected to the digital equivalent of any conventional darkroom manipulation and modern software allows much more flexibility, to such an extent that a new tool for scientific fraud has been created. For research, image enhancement and analysis is an increasingly powerful and affordable tool. Morphometric measurements are, after many predictions, at last beginning to be part of the toolkit of the diagnostic pathologist. In teaching, the potential to create dramatic yet informative presentations is demonstrated daily by the publishing industry; such methods are readily applicable to the classroom. The combination of digital images and the Internet raises many possibilities; for example, instead of seeking one expert diagnostic opinion, one could simultaneously seek the opinion of many, all around the globe. It is inevitable that in the coming years the use of digital images will spread from the laboratory to the medical curriculum and to the whole of diagnostic pathology.

  8. Quality control in diagnostic immunohistochemistry: integrated on-slide positive controls.

    Science.gov (United States)

    Bragoni, A; Gambella, A; Pigozzi, S; Grigolini, M; Fiocca, R; Mastracci, L; Grillo, F

    2017-11-01

    Standardization in immunohistochemistry is a priority in modern pathology and requires strict quality control. Cost containment has also become fundamental and auditing of all procedures must take into account both these principles. Positive controls must be routinely performed so that their positivity guarantees the appropriateness of the immunohistochemical procedure. The aim of this study is to develop a low cost (utilizing a punch biopsy-PB-tool) procedure to construct positive controls which can be integrated in the patient's tissue slide. Sixteen frequently used control blocks were selected and multiple cylindrical samples were obtained using a 5-mm diameter punch biopsy tool, separately re-embedding them in single blocks. For each diagnostic immunoreaction requiring a positive control, an integrated PB-control section (cut from the appropriate PB-control block) was added to the top right corner of the diagnostic slide before immunostaining. This integrated control technique permitted a saving of 4.75% in total direct lab costs and proved to be technically feasible and reliable. Our proposal is easy to perform and within the reach of all pathology labs, requires easily available tools, its application costs is less than using external paired controls and ensures that a specific control for each slide is always available.

  9. Using a digital signal processor as a data stream controller for digital subtraction angiography

    International Nuclear Information System (INIS)

    Meng, J.D.; Katz, J.E.

    1991-10-01

    High speed, flexibility, and good arithmetic abilities make digital signal processors (DSP) a good choice as input/output controllers for real time applications. The DSP can be made to pre-process data in real time to reduce data volume, to open early windows on what is being acquired and to implement local servo loops. We present an example of a DSP as an input/output controller for a digital subtraction angiographic imaging system. The DSP pre-processes the raw data, reducing data volume by a factor of two, and is potentially capable of producing real-time subtracted images for immediate display

  10. Attitude Control of a Satellite by using Digital Signal Processing

    Directory of Open Access Journals (Sweden)

    Adirelle C. Santana

    2012-03-01

    Full Text Available This article has discussed the development of a three-axis attitude digital controller for an artificial satellite using a digital signal processor. The main motivation of this study is the attitude control system of the satellite Multi-Mission Platform, developed by the Brazilian National Institute for Space Research for application in different sort of missions. The controller design was based on the theory of the Linear Quadratic Gaussian Regulator, synthesized from the linearized model of the motion of the satellite, i.e., the kinematics and dynamics of attitude. The attitude actuators considered in this study are pairs of cold gas jets powered by a pulse width/pulse frequency modulator. In the first stage of the project development, a system controller for continuous time was studied with the aim of testing the adequacy of the adopted control. The next steps had included an analysis of discretization techniques, the setting time of sampling rate, and the testing of the digital version of the Linear Quadratic Gaussian Regulator controller in the MATLAB/SIMULINK. To fulfill the study, the controller was implemented in a digital signal processor, specifically the Blackfin BF537 from Analog Devices, along with the pulse width/pulse frequency modulator. The validation tests used a scheme of co-simulation, where the model of the satellite was simulated in MATLAB/SIMULINK, while the controller and modulator were processed in the digital signal processor with a tool called Processor-In-the-Loop, which acted as a data communication link between both environments.function and required time to achieve a given mission accuracy are determined, and results are provided as illustration.

  11. Controlled sharing of personal content using digital rights management

    NARCIS (Netherlands)

    Conrado, C.; Petkovic, M.; Veen, van der M.; Velde, van der W.H.

    2006-01-01

    This paper describes a system which allows controlled distribution of personal digital content by users. The system extends an existing Digital Rights Management system for the protection of commercial copyrighted content by essentially allowing users to become content providers. This fact, however,

  12. Diagnostic accuracy of fracture detection in suspected non-accidental injury: the effect of edge enhancement and digital display on observer performance

    Energy Technology Data Exchange (ETDEWEB)

    Offiah, A.C. [Department of Radiology, Great Ormond Street Hospital for Children, London (United Kingdom) and Institute of Child Health, London (United Kingdom)]. E-mail: amaka.offiah@gosh.nhs.uk; Moon, L. [Department of Radiology, Great Ormond Street Hospital for Children, London (United Kingdom); Hall, C.M. [Department of Radiology, Great Ormond Street Hospital for Children, London (United Kingdom); Todd-Pokropek, A. [Department of Medical Physics and Bioengineering, University College London, London (United Kingdom)

    2006-02-15

    AIM: To compare the effect of varying degrees of edge enhancement and method of digital image display on fracture detection in suspected non-accidental injury (NAI). MATERIALS AND METHODS: Fifty radiographs from post-mortem skeletal surveys in 13 children with suspected NAI were selected. Images were obtained using a Fuji 5000R computed radiography system. Hard copies were printed with edge enhancement factors 0, 0.5 and 1.2. Images (edge enhancement 0.5) were also displayed on a 1K{sup 2} monitor. Six observers independently evaluated all 200 images for the presence of abnormality. Observers also scored each image for visualization of soft tissues, visualization of trabecular markings and overall image quality. The paired Student's t-test and location receiver operating curve (ROC) analysis were used to compare quality scores and diagnostic accuracy of each display method. Individual and pooled true-positive rates (sensitivity) were determined. For the purposes of ROC analysis, histology was taken as the gold standard. RESULTS: There was no difference in duration of hard and soft-copy reading sessions (p=0.76). After image manipulation soft-copy radiographs scored significantly better for image quality than hard copy (p<0.0001). Pooled observer sensitivity (at a specificity of 90%) was below 50% for all display methods. Diagnostic accuracy varied significantly between observers. Diagnostic accuracy of individual observers was not affected by display method. CONCLUSION: In suspected NAI, diagnostic accuracy of fracture detection is generally low. Diagnostic accuracy appears to be affected more by observer-related factors than by the method of digital image display.

  13. Enzymatic Fuel Cells: Towards Self-Powered Implantable and Wearable Diagnostics.

    Science.gov (United States)

    Gonzalez-Solino, Carla; Lorenzo, Mirella Di

    2018-01-29

    With the rapid progress in nanotechnology and microengineering, point-of-care and personalised healthcare, based on wearable and implantable diagnostics, is becoming a reality. Enzymatic fuel cells (EFCs) hold great potential as a sustainable means to power such devices by using physiological fluids as the fuel. This review summarises the fundamental operation of EFCs and discusses the most recent advances for their use as implantable and wearable self-powered sensors.

  14. Enzymatic Fuel Cells: Towards Self-Powered Implantable and Wearable Diagnostics

    OpenAIRE

    Carla Gonzalez-Solino; Mirella Di Lorenzo

    2018-01-01

    With the rapid progress in nanotechnology and microengineering, point-of-care and personalised healthcare, based on wearable and implantable diagnostics, is becoming a reality. Enzymatic fuel cells (EFCs) hold great potential as a sustainable means to power such devices by using physiological fluids as the fuel. This review summarises the fundamental operation of EFCs and discusses the most recent advances for their use as implantable and wearable self-powered sensors.

  15. Quality control in diagnostic radiology: experience and challenges

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Mohd Ramli Arshad; Mohd Khalid Matori; Muhammad Jamal Md Isa; Husaini Salleh; Abdullah Tahir Aliyasak; Zainal Jamaluddin; Hasrul Hisham Hussain

    2005-01-01

    Malaysian Institute for Nuclear Technology Research through its Medical Physics Group has been providing Quality Control (QC) services for medical x-ray apparatus used in diagnostic radiology to private clinics and hospitals since the year 1997. The quality control (QC) in diagnostic radiology is considered as part of quality assurance program which provide accurate diagnostic information at the lowest cost and the least exposure of the patients to radiation. Many experience and obstacles were faced by Medical Physics Group. This paper will discuss on some of the experiences and challenges that could be shared together with MINT staff especially in the safety aspect related to electrical and mechanical, radiation protection, performance and standard. The challenging in administrative aspect also will discuss. (Author)

  16. Exercising self-control increases approach motivation.

    Science.gov (United States)

    Schmeichel, Brandon J; Harmon-Jones, Cindy; Harmon-Jones, Eddie

    2010-07-01

    The present research tested the hypothesis that exercising self-control causes an increase in approach motivation. Study 1 found that exercising (vs. not exercising) self-control increases self-reported approach motivation. Study 2a identified a behavior--betting on low-stakes gambles--that is correlated with approach motivation but is relatively uncorrelated with self-control, and Study 2b observed that exercising self-control temporarily increases this behavior. Last, Study 3 found that exercising self-control facilitates the perception of a reward-relevant symbol (i.e., a dollar sign) but not a reward-irrelevant symbol (i.e., a percent sign). Altogether, these results support the hypothesis that exercising self-control temporarily increases approach motivation. Failures of self-control that follow from prior efforts at self-control (i.e., ego depletion) may be explained in part by increased approach motivation.

  17. Direct digital temperature control of the A-1 nuclear reactor

    International Nuclear Information System (INIS)

    Karpeta, C.

    1975-01-01

    The application is described of one of the modern control methods for designing an experimental digital temperature control system for heavy water moderated gas cooled reactors. The synthesis of the optimal stochastic regulator for reactor control in the area of the rated steady state was carried out using the method of dynamic programming and the Kalman filter technique. The analysis of the feedback circuit was conducted using control simulation on a universal digital computer. Results and experience are summed up. (author)

  18. Reliability Estimation for Digital Instrument/Control System

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yaguang; Sydnor, Russell [U.S. Nuclear Regulatory Commission, Washington, D.C. (United States)

    2011-08-15

    Digital instrumentation and controls (DI and C) systems are widely adopted in various industries because of their flexibility and ability to implement various functions that can be used to automatically monitor, analyze, and control complicated systems. It is anticipated that the DI and C will replace the traditional analog instrumentation and controls (AI and C) systems in all future nuclear reactor designs. There is an increasing interest for reliability and risk analyses for safety critical DI and C systems in regulatory organizations, such as The United States Nuclear Regulatory Commission. Developing reliability models and reliability estimation methods for digital reactor control and protection systems will involve every part of the DI and C system, such as sensors, signal conditioning and processing components, transmission lines and digital communication systems, D/A and A/D converters, computer system, signal processing software, control and protection software, power supply system, and actuators. Some of these components are hardware, such as sensors and actuators, their failure mechanisms are well understood, and the traditional reliability model and estimation methods can be directly applied. But many of these components are firmware which has software embedded in the hardware, and software needs special consideration because its failure mechanism is unique, and the reliability estimation method for a software system will be different from the ones used for hardware systems. In this paper, we will propose a reliability estimation method for the entire DI and C system reliability using a recently developed software reliability estimation method and a traditional hardware reliability estimation method.

  19. Reliability Estimation for Digital Instrument/Control System

    International Nuclear Information System (INIS)

    Yang, Yaguang; Sydnor, Russell

    2011-01-01

    Digital instrumentation and controls (DI and C) systems are widely adopted in various industries because of their flexibility and ability to implement various functions that can be used to automatically monitor, analyze, and control complicated systems. It is anticipated that the DI and C will replace the traditional analog instrumentation and controls (AI and C) systems in all future nuclear reactor designs. There is an increasing interest for reliability and risk analyses for safety critical DI and C systems in regulatory organizations, such as The United States Nuclear Regulatory Commission. Developing reliability models and reliability estimation methods for digital reactor control and protection systems will involve every part of the DI and C system, such as sensors, signal conditioning and processing components, transmission lines and digital communication systems, D/A and A/D converters, computer system, signal processing software, control and protection software, power supply system, and actuators. Some of these components are hardware, such as sensors and actuators, their failure mechanisms are well understood, and the traditional reliability model and estimation methods can be directly applied. But many of these components are firmware which has software embedded in the hardware, and software needs special consideration because its failure mechanism is unique, and the reliability estimation method for a software system will be different from the ones used for hardware systems. In this paper, we will propose a reliability estimation method for the entire DI and C system reliability using a recently developed software reliability estimation method and a traditional hardware reliability estimation method

  20. Robust Self Tuning Controllers

    DEFF Research Database (Denmark)

    Poulsen, Niels Kjølstad

    1985-01-01

    The present thesis concerns robustness properties of adaptive controllers. It is addressed to methods for robustifying self tuning controllers with respect to abrupt changes in the plant parameters. In the thesis an algorithm for estimating abruptly changing parameters is presented. The estimator...... has several operation modes and a detector for controlling the mode. A special self tuning controller has been developed to regulate plant with changing time delay.......The present thesis concerns robustness properties of adaptive controllers. It is addressed to methods for robustifying self tuning controllers with respect to abrupt changes in the plant parameters. In the thesis an algorithm for estimating abruptly changing parameters is presented. The estimator...

  1. Digitized molecular diagnostics: reading disk-based bioassays with standard computer drives.

    Science.gov (United States)

    Li, Yunchao; Ou, Lily M L; Yu, Hua-Zhong

    2008-11-01

    We report herein a digital signal readout protocol for screening disk-based bioassays with standard optical drives of ordinary desktop/notebook computers. Three different types of biochemical recognition reactions (biotin-streptavidin binding, DNA hybridization, and protein-protein interaction) were performed directly on a compact disk in a line array format with the help of microfluidic channel plates. Being well-correlated with the optical darkness of the binding sites (after signal enhancement by gold nanoparticle-promoted autometallography), the reading error levels of prerecorded audio files can serve as a quantitative measure of biochemical interaction. This novel readout protocol is about 1 order of magnitude more sensitive than fluorescence labeling/scanning and has the capability of examining multiplex microassays on the same disk. Because no modification to either hardware or software is needed, it promises a platform technology for rapid, low-cost, and high-throughput point-of-care biomedical diagnostics.

  2. Comparison of digital selenium radiography with an analog screen-film system in the diagnostic process of pneumoconiosis according to ILO classification

    International Nuclear Information System (INIS)

    Zaehringer, M.; Winnekendonk, G.; Gossmann, A.; Krueger, K.; Krug, B.

    2001-01-01

    Purpose: The aim of the study was to determine the diagnostic value of digital selenium radiography in patients with pneumoconiosis. For this purpose chest X-rays by digital selenium radiography and analog screen-film system were compared according to the ILO classification of pneumoconiosis. Method: After approval of the study by the local ethic commission and the Federal German Office for Radiation Protection 50 patients were subjected to X-rays by digital selenium radiography (Thoravision; Philips Medical Systems, Hamburg, Germany) and analog screen-film system of the same day within the scope of an industrial medicine preventive checkup. Four investigators rated the chest X-rays according to the ILO classification of pneumoconiosis. Results: The findings demonstrated by chest X-rays according to ILO classification were rated similar by digital selenium radiography and analog screen film systems. Image quality of the digital pictures was rated significantly better. Conclusion: The use of digital selenium radiography in evaluating chest X-rays according to the ILO classification does not result in over- or underestimation of pulmonary pathologies. Hence, in the diagnosis of pneumoconiosis, digital selenium radiography can replace the tested analog screen-film system. (orig.) [de

  3. ISTTOK plasma control with the tomography diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, H.; Caralho, P.J.; Duarte, P.; Pereira, T.; Coelho, R.; Silva, C. [Association Euratom/IST, Institute of Plasmas and Nuclear Fusion, Technology Graduate Institute, P-1049-001 Lisbon (Portugal)

    2011-07-01

    A real-time plasma position control system is mandatory to achieve long duration (up to 250 ms), Alternating Current (AC) discharges on the ISTTOK tokamak. Such a system has been used for some time supported only on magnetic field diagnostic data. However, this system does not function accurately when the plasma current is low, rendering it inoperative during the plasma current reversal. A tomography diagnostic with 3 pinhole cameras and 8 silicone photodiode channels per camera was installed and customized to supply alternative plasma position to be used for plasma position control. As no filtering is applied, most of the radiation detected is in the visible/near-UV range. This system (i) executes a tomographic reconstruction, (ii) determines the average emissivity position from it, (iii) calculates the shift from the required position and (iv) supplies the vertical field power supply unit with the desired current value, all in less than 100 {mu}s. The horizontal magnetic field power supply unit is expected to be included in the system and will have no impact in the process time. This paper presents the tomography diagnostic architecture together with results of its scientific exploitation in ISTTOK AC discharges, where it has proven to be capable of supplying an accurate plasma position during the current reversal. The use of the tomography diagnostic for plasma position overcomes some limitations of the magnetic diagnostics, but poses challenges of its own such as blindness to plasma current direction. (authors)

  4. The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study.

    Science.gov (United States)

    Menem, R; Barngkgei, I; Beiruti, N; Al Haffar, I; Joury, Easter

    2017-04-01

    The aim of this in vivo study was to test the diagnostic accuracy of a pen-type laser fluorescence (LFpen) device in detecting approximal caries lesions, in posterior permanent teeth, at the cavitation and non-cavitation thresholds, and compare it with that of digital bitewing radiography. Thirty patients (aged 18-37), who attended the Faculty of Dentistry at Damascus University for a dental examination, were consecutively screened. Ninety approximal surfaces of posterior permanent teeth without frank cavitations, enamel hypoplasia or restorations were selected and examined using the LFpen (DIAGNOdent pen) and digital bitewing radiography. The reference standard was the visual-tactile inspection, after performing temporary tooth separation, using orthodontic rubber rings, placed for 7 days. The status of included approximal surfaces was recorded as intact/sound, with white/brown spots or cavitated. One trained examiner performed all examinations. There were statistically significant differences in LFpen readings between the three types of approximal surface status (P 16 and 8 at the cavitation and non-cavitation thresholds respectively. The sensitivity, specificity and accuracy (measured by the area under the receiver-operating characteristic curve) were 100, 85 and 95 and 92, 90 and 95% at the cavitation and non-cavitation thresholds respectively. The intra-class correlation coefficient for intra-examiner reliability was 0.95. The diagnostic accuracy of the LFpen was significantly higher than that of digital bitewing radiography (P < 0.001). The LFpen's diagnostic performance was accurate and significantly better than digital bitewing radiography in detecting approximal caries lesions, in posterior permanent teeth.

  5. Proton storage ring (PSR) diagnostics and control system

    International Nuclear Information System (INIS)

    Clout, P.

    1983-01-01

    When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system

  6. Self-Control Strength Depletion Reduces Self-Efficacy and Impairs Exercise Performance.

    Science.gov (United States)

    Graham, Jeffrey D; Bray, Steven R

    2015-10-01

    The purpose of this study was to investigate the role of task self-efficacy as a psychological factor involved in the relationship between self-control depletion and physical endurance. Participants (N = 37) completed two isometric handgrip endurance trials, separated by a Stroop task, which was either congruent (control) or incongruent (causing depletion). Task self-efficacy for the second endurance trial was measured following the Stroop task. Participants in the depletion condition reported lower task self-efficacy and showed a greater reduction in performance on the second endurance trial when compared with controls. Task self-efficacy also mediated the relationship between self-control depletion and endurance performance. The results of this study provide evidence that task self-efficacy is negatively affected following self-control depletion. We recommend that task self-efficacy be further investigated as a psychological factor accounting for the negative change in self-control performance of physical endurance and sport tasks following self-control strength depletion.

  7. A digital control and monitoring system for PWR waste-disposal systems

    International Nuclear Information System (INIS)

    Ueda, Toshiharu; Fuchigami, Kazuyuki; Shimozato, Masao; Takazawa, Kazuo

    1982-01-01

    Mitsubishi Electric has developed a digital control and monitoring system for PWR waste-disposal systems. This novel system has improved operability due to its automated operations and control, and integrated supervisory functions. The system includes other features to improve operability: sequence control by a control computer, direct-digital process control, integrated supervision of operation states by a supervisory computer and a high-speed dataway, and CRT interfacing between the computer and dataway. (author)

  8. Digital PI-PD controller design for arbitrary order systems: Dominant pole placement approach.

    Science.gov (United States)

    Dincel, Emre; Söylemez, Mehmet Turan

    2018-05-02

    In this paper, a digital PI-PD controller design method is proposed for arbitrary order systems with or without time-delay to achieve desired transient response in the closed-loop via dominant pole placement approach. The digital PI-PD controller design problem is solved by converting the original problem to the digital PID controller design problem. Firstly, parametrization of the digital PID controllers which assign dominant poles to desired location is done. After that the subset of digital PID controller parameters in which the remaining poles are located away from the dominant pole pair is found via Chebyshev polynomials. The obtained PID controller parameters are then transformed into the PI-PD controller parameters by considering the closed-loop controller zero and the design is completed. Success of the proposed design method is firstly demonstrated on an example transfer function and compared with the well-known PID controller methods from the literature through simulations. After that the design method is implemented on the fan and plate laboratory system in a real environment. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  9. Digital feed back control for radial beam position

    International Nuclear Information System (INIS)

    Mestha, L.K.

    1989-09-01

    In the development of wide spread large scale distributed digital control systems, there is a requirement to automate small processes like radial beam control which will not only improve the beam quality but will also add local intelligence. Hence use is made here of digital control principles for such applications. The work concerned with the radial beam control discussed in this report has been developed for ISIS at RAL. The structure of the report is hence inclined more towards the local hardware system. The general feed back loop techniques can also be implemented for other control purpose. For instance, the author has successfully tested similar techniques to minimise the RF cavity tuning error, where the improvement in performance could not be matched by the analogue loop. A description of the RF cavity tuning programme and the associated experimental results will be published as a local paper for ISIS division. (author)

  10. Quality Control in Diagnostic Radiology in the Netherlands (invited paper)

    International Nuclear Information System (INIS)

    Zoetelief, J.

    1998-01-01

    Application of the general principles of radiation protection to medical diagnostic radiology implies that each procedure using X rays or radionuclides is to be justified and optimised. Optimisation in diagnostic radiology implies that the radiation burden to the patient should be as low as possible, but compatible with the image quality necessary to obtain an adequate diagnosis or to guide treatment. Quality control of equipment is a prerequisite for achieving optimisation in diagnostic radiology. This was especially recognised for mammography as employed for breast cancer screening. Existing legislation in the Netherlands includes only a few criteria for equipment used in diagnostic radiology. In addition, the criteria are not all operational and measurement methods are lacking. Therefore, upon the initiative of the Dutch Ministry of Health, Welfare and Sports, the relevant professional societies, in collaboration with the former TNO Centre for Radiological Protection and Dosimetry, formulated eleven guidelines for quality control of equipment used in diagnostic radiology, including test procedures, test frequencies and limiting values. The implementation of quality control of equipment was included in the 1984 European Directive (84/466/Euratom) laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. In the most recent European Directive on medical exposure (97/43/Euratom) the importance of quality control is stressed. In addition, the latter EC directive proposes the use of diagnostic reference levels for limiting the risks for patients undergoing diagnostic radiology. In the Netherlands preliminary reference levels for various procedures employed in diagnostic radiology are suggested. Finally, methods applied in the Netherlands for assessment of image quality are discussed. (author)

  11. The development of digital oscilloscope control software in nuclear measurement

    International Nuclear Information System (INIS)

    Pu Minghui; Tian Geng; Li Xianyou

    2004-01-01

    This essay presents the development of an all-purpose digital oscilloscope control software on Windows 95/98 OS. The background and method are discussed in detail, together with the function and characteristics of the software. With the use of this software, a single PC can control several digital oscilloscopes. Solution of main problems encountered in the development is also discussed. (authors)

  12. Engineering integrated digital circuits with allosteric ribozymes for scaling up molecular computation and diagnostics.

    Science.gov (United States)

    Penchovsky, Robert

    2012-10-19

    Here we describe molecular implementations of integrated digital circuits, including a three-input AND logic gate, a two-input multiplexer, and 1-to-2 decoder using allosteric ribozymes. Furthermore, we demonstrate a multiplexer-decoder circuit. The ribozymes are designed to seek-and-destroy specific RNAs with a certain length by a fully computerized procedure. The algorithm can accurately predict one base substitution that alters the ribozyme's logic function. The ability to sense the length of RNA molecules enables single ribozymes to be used as platforms for multiple interactions. These ribozymes can work as integrated circuits with the functionality of up to five logic gates. The ribozyme design is universal since the allosteric and substrate domains can be altered to sense different RNAs. In addition, the ribozymes can specifically cleave RNA molecules with triplet-repeat expansions observed in genetic disorders such as oculopharyngeal muscular dystrophy. Therefore, the designer ribozymes can be employed for scaling up computing and diagnostic networks in the fields of molecular computing and diagnostics and RNA synthetic biology.

  13. Enzymatic Fuel Cells: Towards Self-Powered Implantable and Wearable Diagnostics

    Science.gov (United States)

    Gonzalez-Solino, Carla; Lorenzo, Mirella Di

    2018-01-01

    With the rapid progress in nanotechnology and microengineering, point-of-care and personalised healthcare, based on wearable and implantable diagnostics, is becoming a reality. Enzymatic fuel cells (EFCs) hold great potential as a sustainable means to power such devices by using physiological fluids as the fuel. This review summarises the fundamental operation of EFCs and discusses the most recent advances for their use as implantable and wearable self-powered sensors. PMID:29382147

  14. Enzymatic Fuel Cells: Towards Self-Powered Implantable and Wearable Diagnostics

    Directory of Open Access Journals (Sweden)

    Carla Gonzalez-Solino

    2018-01-01

    Full Text Available With the rapid progress in nanotechnology and microengineering, point-of-care and personalised healthcare, based on wearable and implantable diagnostics, is becoming a reality. Enzymatic fuel cells (EFCs hold great potential as a sustainable means to power such devices by using physiological fluids as the fuel. This review summarises the fundamental operation of EFCs and discusses the most recent advances for their use as implantable and wearable self-powered sensors.

  15. Digital remote control system for power supplies of particle channel magnetooptical elements

    International Nuclear Information System (INIS)

    Vetrov, P.B.; Ermolina, G.P.; Kuznetsov, V.S.; Mojbenko, A.N.

    1986-01-01

    Current control of magnetooptical elements of accelerator particle channels is based on control of reference voltage of current stabilizers. Advent of industrial multidigit (12 bits) integral analog-to-digital converters permitted to develop simple digital sources of reference voltage. A digital control system of 30 spatially remoted power supplies of magnetooptical elements of particle channels on the basis of the ''Elektronika-60'' microcomputer is described. The microcomputer is connected by the standard communication line (20 mA) with the SM-4 computer. The ''Summa'' crate is connected with the microcomputer through the branch driver. Digit data are transmitted by the multibranch trunk of sequential communication (Manchester-2 code) at the rate of 0.5 Mband. Feedback was realized by connection of analog signals through the distributed commutator to the measuring line with a digital voltmeter

  16. Digital linear control theory applied to automatic stepsize control in electrical circuit simulation

    NARCIS (Netherlands)

    Verhoeven, A.; Beelen, T.G.J.; Hautus, M.L.J.; Maten, ter E.J.W.; Di Bucchianico, A.; Mattheij, R.M.M.; Peletier, M.A.

    2006-01-01

    Adaptive stepsize control is used to control the local errors of the numerical solution. For optimization purposes smoother stepsize controllers are wanted, such that the errors and stepsizes also behave smoothly. We consider approaches from digital linear control theory applied to multistep

  17. Digital linear control theory applied to automatic stepsize control in electrical circuit simulation

    NARCIS (Netherlands)

    Verhoeven, A.; Beelen, T.G.J.; Hautus, M.L.J.; Maten, ter E.J.W.

    2005-01-01

    Adaptive stepsize control is used to control the local errors of the numerical solution. For optimization purposes smoother stepsize controllers are wanted, such that the errors and stepsizes also behave smoothly. We consider approaches from digital linear control theory applied to multistep

  18. Clinical Diagnostic and Sociocultural Dimensions of Deliberate Self-Harm in Mumbai, India

    Science.gov (United States)

    Parkar, Shubhangi R.; Dawani, Varsha; Weiss, Mitchell G.

    2006-01-01

    Patients' accounts complement psychiatric assessment of deliberate self-harm (DSH). In this study we examined psychiatric disorders, and sociocultural and cross-cultural features of DSH. SCID diagnostic interviews and a locally adapted EMIC interview were used to study 196 patients after DSH at a general hospital in Mumbai, India. Major depression…

  19. The Security Research of Digital Library Network

    Science.gov (United States)

    Zhang, Xin; Song, Ding-Li; Yan, Shu

    Digital library is a self-development needs for the modern library to meet the development requirements of the times, changing the way services and so on. digital library from the hardware, technology, management and other aspects to objective analysis of the factors of threats to digital library network security. We should face up the problems of digital library network security: digital library network hardware are "not hard", the technology of digital library is relatively lag, digital library management system is imperfect and other problems; the government should take active measures to ensure that the library funding, to enhance the level of network hardware, to upgrade LAN and prevention technology, to improve network control technology, network monitoring technology; to strengthen safety management concepts, to prefect the safety management system; and to improve the level of security management modernization for digital library.

  20. Documenting control system functionality for digital control implementations

    International Nuclear Information System (INIS)

    Harber, J.; Borairi, M.; Tikku, S.; Josefowicz, A.

    2006-01-01

    In past CANDU designs, plant control was accomplished by a combination of digital control computers, analogue controllers, and hardwired relay logic. Functionality for these various control systems, each using different hardware, was documented in varied formats such as text based program specifications, relay logic diagrams, and other various specification documents. The choice of formats was influenced by the hardware used and often required different specialized skills for different applications. The programmable electronic systems in new CANDU designs are realized in a manner consistent with latest international standards (e.g., the IEC 61513 standard). New CANDU designs make extensive use of modern digital control technology, with the benefit that functionality can be implemented on a limited number of control platforms, reducing development and maintenance cost. This approach can take advantage of tools that allow the plant control system functional and performance requirements to be documented using graphical representations. Modern graphical methods supplemented by information databases can be used to provide a clear and comprehensive set of requirements for software and system development. Overview diagrams of system functionality provide a common understanding of the system boundaries and interfaces. Important requirements are readily traced through the development process. This improved reviewability helps to ensure consistency with the safety and and production design requirements of the system. Encapsulation of commonly used functions into custom-defined function blocks, such as typical motor control centre interfaces, process interlocks, median selects etc, eases the burden on designers to understand and analyze the detailed functionality of each instance of use of this logic. A library of encapsulated functions will be established for complex functions that are reused in the control logic development. By encapsulation and standardisation of such

  1. Development of a majority vote decision module for a self-diagnostic monitoring system for an air-operated valve system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo Shin [Dept. of Information and Communication Engineering, Sejong University, Seoul (Korea, Republic of); Chai, Jang Bom [Dept. of Mechanical Engineering, Ajou University, Suwon (Korea, Republic of); Kim, In Taek [Dept. of Information and Communication Engineering, Myongji University, Yongin (Korea, Republic of)

    2015-08-15

    A self-diagnostic monitoring system is a system that has the ability to measure various physical quantities such as temperature, pressure, or acceleration from sensors scattered over a mechanical system such as a power plant, in order to monitor its various states, and to make a decision about its health status. We have developed a self-diagnostic monitoring system for an air-operated valve system to be used in a nuclear power plant. In this study, we have tried to improve the self-diagnostic monitoring system to increase its reliability. We have implemented three different machine learning algorithms, i.e., logistic regression, an artificial neural network, and a support vector machine. After each algorithm performs the decision process independently, the decision-making module collects these individual decisions and makes a final decision using a majority vote scheme. With this, we performed some simulations and presented some of its results. The contribution of this study is that, by employing more robust and stable algorithms, each of the algorithms performs the recognition task more accurately. Moreover, by integrating these results and employing the majority vote scheme, we can make a definite decision, which makes the self-diagnostic monitoring system more reliable.

  2. Development of a majority vote decision module for a self-diagnostic monitoring system for an air-operated valve system

    International Nuclear Information System (INIS)

    Kim, Woo Shin; Chai, Jang Bom; Kim, In Taek

    2015-01-01

    A self-diagnostic monitoring system is a system that has the ability to measure various physical quantities such as temperature, pressure, or acceleration from sensors scattered over a mechanical system such as a power plant, in order to monitor its various states, and to make a decision about its health status. We have developed a self-diagnostic monitoring system for an air-operated valve system to be used in a nuclear power plant. In this study, we have tried to improve the self-diagnostic monitoring system to increase its reliability. We have implemented three different machine learning algorithms, i.e., logistic regression, an artificial neural network, and a support vector machine. After each algorithm performs the decision process independently, the decision-making module collects these individual decisions and makes a final decision using a majority vote scheme. With this, we performed some simulations and presented some of its results. The contribution of this study is that, by employing more robust and stable algorithms, each of the algorithms performs the recognition task more accurately. Moreover, by integrating these results and employing the majority vote scheme, we can make a definite decision, which makes the self-diagnostic monitoring system more reliable

  3. The daily digital practice as a form of self-care: Using photography for everyday well-being.

    Science.gov (United States)

    Brewster, Liz; Cox, Andrew M

    2018-04-01

    Interest in the connection between involvement in digital communities and well-being has increased as these communities become more commonplace. Specific models of interaction that affect well-being have emerged; here, we examine one of those models, termed 'digital daily practice'. Digital daily practices involve a commitment to doing one thing - exercise, photography and writing - every day and sharing it online. Participants in these practices agree that they provide an unexpected benefit of improving well-being. This article makes an in-depth examination of one digital daily practice, photo-a-day, using a practice theory framework to understand the affordances it offers for well-being. We engage with the literature on well-being and self-care, critiquing its presentation of well-being as an individual trait. We present data from an ethnographic study including interviews and observations to highlight how photo-a-day as a practice functions as self-care and how communities are formed around it. Photo-a-day is not a simple and uncomplicated practice; rather it is the complex affordances and variance within the practice that relate it to well-being. We conclude that this practice has multi-faceted benefits for improving well-being.

  4. Digital displacements

    DEFF Research Database (Denmark)

    Pors, Anja Svejgaard

    2014-01-01

    In recent years digital reforms are being introduced in the municipal landscape of Denmark. The reforms address the interaction between citizen and local authority. The aim is, that by 2015 at least 80 per cent of all correspondence between citizens and public authority will be transmitted through...... digital interface. However, the transformation of citizen services from traditional face-to-face interaction to digital self-service gives rise to new practices; some citizens need support to be able to manage self-service through digital tools. A mixture of support and teaching, named co......-service, is a new task in public administration, where street level bureaucrats assist citizens in using the new digital solutions. The paper is based on a case study conducted primarily in a citizen service centre in Copenhagen, Denmark. Based on ethnography the paper gives an empirical account of the ongoing...

  5. Analog and digital appliance technology for the control and monitoring of space HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Gyoeri, M

    1987-01-01

    Both analog and digital devices are expected to meet the required control functions. The analog control device meets this function by way of a complicated circuitry and wiring technology of varying sophistication. In the digital control by a preprogrammed microprocessor. Digital technology allows to use the copied programme in different devices. Any change in the control of a system can be implemented and met by a programme change in digital technology. In analog technology, this change involves a change in wiring. (orig./HW).

  6. Epidemiological evidence for the risk of cancer from diagnostic X-rays

    International Nuclear Information System (INIS)

    Berrington, A.

    2001-01-01

    The magnitude of the risk of cancer following exposure to a single moderate or high dose of ionising radiation has been studied extensively and is quite well understood. The size of the risk of cancer from diagnostic X-rays, which are low dose, fractionated exposures and constitute the largest man-made source of radiation exposure, is much more uncertain. The aim of this thesis is to evaluate the risk of cancer to radiologists and to the population from exposure to diagnostic X-rays using various epidemiological methods. The effect of fractionated radiation exposure was investigated in a cohort of 2698 British radiologists who first registered with a radiological society after 1921. There was no evidence of an overall excess risk of cancer mortality. However, there was evidence of an increasing trend in cancer mortality with time since registration with the society (p=0.0002), such that those who had first registered more than 40 years previously had a 41% (95% Cl: 3% to 90%) excess risk compared to cancer mortality rates for all medical practitioners. Indirect estimates of the risk of cancer from diagnostic X-rays to the population were calculated with lifetable methods. Using data on the current annual frequency of diagnostic X-ray exposures to the population, estimated organ doses from these X-rays and models for the risk of cancer from the Japanese atomic bomb survivors, it was estimated that 1.5% of the lifetime risk of cancer in the U.K. population could be attributable to diagnostic X-ray exposures. In fourteen other developed countries estimates ranged from 1.6% in Finland to 8.6% in Japan. Several published case-control studies of leukaemia, brain and parotid gland tumours and thyroid cancer demonstrated significant excess risks with self-reported exposures to diagnostic X-rays. Analysis of original data from a case-control study of thyroid cancer in Kuwait also found a significant trend in risk with estimated thyroid dose from self-reported upper-body X

  7. A monitor for the laboratory evaluation of control integrity in digital control systems operating in harsh electromagnetic environments

    Science.gov (United States)

    Belcastro, Celeste M.; Fischl, Robert; Kam, Moshe

    1992-01-01

    This paper presents a strategy for dynamically monitoring digital controllers in the laboratory for susceptibility to electromagnetic disturbances that compromise control integrity. The integrity of digital control systems operating in harsh electromagnetic environments can be compromised by upsets caused by induced transient electrical signals. Digital system upset is a functional error mode that involves no component damage, can occur simultaneously in all channels of a redundant control computer, and is software dependent. The motivation for this work is the need to develop tools and techniques that can be used in the laboratory to validate and/or certify critical aircraft controllers operating in electromagnetically adverse environments that result from lightning, high-intensity radiated fields (HIRF), and nuclear electromagnetic pulses (NEMP). The detection strategy presented in this paper provides dynamic monitoring of a given control computer for degraded functional integrity resulting from redundancy management errors, control calculation errors, and control correctness/effectiveness errors. In particular, this paper discusses the use of Kalman filtering, data fusion, and statistical decision theory in monitoring a given digital controller for control calculation errors.

  8. Digital radiography of the chest

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Hachiya, Junichi; Korenaga, Tateo; Nitatori, Toshiaki; Miyasaka, Yasuo; Furuya, Yoshiro

    1984-01-01

    Initial clinical experience in digital chest radiography utilizing photostimulable phosphor and scanning laser stimulated luminescence was reported. Image quality of conventional film/screen radiography and digital radiography was compared in 30 normal cases. Reflecting wide dynamic range of the system, improved image quality was confirmed in all 30 cases, particularly in visibility of various mediastinal structures and pulmonary vessels. High sensor sensitivity of the system enabled digital radiography to reduce radiation dose requirement significantly. Diagnostically acceptable chest images were obtained with approximately 1/5 of routine dose for conventional radiography without significant image quality degradation. Some artifact created by digital processing were mostly overcome by a routine use of simultaneous display of two different types of image processing and therefore was not an actual drawback from diagnostic standpoint. Further technical advancement of the system to be seen for digital storage, retrieval and tranceference of images. (author)

  9. Nuclear Energy Research Initiative (NERI): On-Line Intelligent Self-Diagnostic Monitoring for Next Generation Nuclear Plants - Phase I Annual Report

    International Nuclear Information System (INIS)

    Bond, L.G.; Doctor, S.R.; Gilbert, R.W.; Jarrell, D.B.; Greitzer, F.L.; Meador, R.J.

    2000-01-01

    OAK-B135 This OSTI ID belongs to an IWO and is being released out of the system. The Program Manager Rebecca Richardson has confirmed that all reports have been received. The objective of this project is to design and demonstrate the operation of the real-time intelligent self-diagnostic and prognostic system for next generation nuclear power plant systems. This new self-diagnostic technology is titled, ''On-Line Intelligent Self-Diagnostic Monitoring System'' (SDMS). This project provides a proof-of-principle technology demonstration for SDMS on a pilot plant scale service water system, where a distributed array of sensors is integrated with active components and passive structures typical of next generation nuclear power reactor and plant systems. This project employs state-of-the-art sensors, instrumentation, and computer processing to improve the monitoring and assessment of the power reactor system and to provide diagnostic and automated prognostics capabilities

  10. A high-performance digital control system for TCV

    International Nuclear Information System (INIS)

    Lister, J.B.; Dutch, M.J.; Milne, P.G.; Means, R.W.

    1997-10-01

    The TCV hybrid analogue-digital plasma control system has been superseded by a high performance Digital Plasma Control System, DPCS, made possible by recent advances in off the shelf technology. We discuss the basic requirements for such a control system and present the design and specifications which were laid down. The nominal and final performances are presented and the complete design is given in detail. The integration of the new system into the current operation of the TCV tokamak is described. The procurement of this system has required close collaboration between the end-users and two commercial suppliers with one of the latter taking full responsibility for the system integration. The impact of this approach on the design and commissioning costs for the TCV project is presented. New possibilities offered by this new system are discussed, including possible work relevant to ITER plasma control development. (author) 3 figs., 5 refs

  11. A high-performance digital control system for TCV

    Energy Technology Data Exchange (ETDEWEB)

    Lister, J.B.; Dutch, M.J. [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP); Milne, P.G. [Pentland System Ltd., Livingstone (United Kingdom); Means, R.W. [HNC Software Inc., San Diego, CA (United States)

    1997-10-01

    The TCV hybrid analogue-digital plasma control system has been superseded by a high performance Digital Plasma Control System, DPCS, made possible by recent advances in off the shelf technology. We discuss the basic requirements for such a control system and present the design and specifications which were laid down. The nominal and final performances are presented and the complete design is given in detail. The integration of the new system into the current operation of the TCV tokamak is described. The procurement of this system has required close collaboration between the end-users and two commercial suppliers with one of the latter taking full responsibility for the system integration. The impact of this approach on the design and commissioning costs for the TCV project is presented. New possibilities offered by this new system are discussed, including possible work relevant to ITER plasma control development. (author) 3 figs., 5 refs.

  12. Automated digital magnetofluidics

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J; Garcia, A A; Marquez, M [Harrington Department of Bioengineering Arizona State University, Tempe AZ 85287-9709 (United States)], E-mail: tony.garcia@asu.edu

    2008-08-15

    Drops can be moved in complex patterns on superhydrophobic surfaces using a reconfigured computer-controlled x-y metrology stage with a high degree of accuracy, flexibility, and reconfigurability. The stage employs a DMC-4030 controller which has a RISC-based, clock multiplying processor with DSP functions, accepting encoder inputs up to 22 MHz, provides servo update rates as high as 32 kHz, and processes commands at rates as fast as 40 milliseconds. A 6.35 mm diameter cylindrical NdFeB magnet is translated by the stage causing water drops to move by the action of induced magnetization of coated iron microspheres that remain in the drop and are attracted to the rare earth magnet through digital magnetofluidics. Water drops are easily moved in complex patterns in automated digital magnetofluidics at an average speed of 2.8 cm/s over a superhydrophobic polyethylene surface created by solvent casting. With additional components, some potential uses for this automated microfluidic system include characterization of superhydrophobic surfaces, water quality analysis, and medical diagnostics.

  13. Automated digital magnetofluidics

    Science.gov (United States)

    Schneider, J.; Garcia, A. A.; Marquez, M.

    2008-08-01

    Drops can be moved in complex patterns on superhydrophobic surfaces using a reconfigured computer-controlled x-y metrology stage with a high degree of accuracy, flexibility, and reconfigurability. The stage employs a DMC-4030 controller which has a RISC-based, clock multiplying processor with DSP functions, accepting encoder inputs up to 22 MHz, provides servo update rates as high as 32 kHz, and processes commands at rates as fast as 40 milliseconds. A 6.35 mm diameter cylindrical NdFeB magnet is translated by the stage causing water drops to move by the action of induced magnetization of coated iron microspheres that remain in the drop and are attracted to the rare earth magnet through digital magnetofluidics. Water drops are easily moved in complex patterns in automated digital magnetofluidics at an average speed of 2.8 cm/s over a superhydrophobic polyethylene surface created by solvent casting. With additional components, some potential uses for this automated microfluidic system include characterization of superhydrophobic surfaces, water quality analysis, and medical diagnostics.

  14. Test and control computer user's guide for a digital beam former test system

    Science.gov (United States)

    Alexovich, Robert E.; Mallasch, Paul G.

    1992-01-01

    A Digital Beam Former Test System was developed to determine the effects of noise, interferers and distortions, and digital implementations of beam forming as applied to the Tracking and Data Relay Satellite 2 (TDRS 2) architectures. The investigation of digital beam forming with application to TDRS 2 architectures, as described in TDRS 2 advanced concept design studies, was conducted by the NASA/Lewis Research Center for NASA/Goddard Space Flight Center. A Test and Control Computer (TCC) was used as the main controlling element of the digital Beam Former Test System. The Test and Control Computer User's Guide for a Digital Beam Former Test System provides an organized description of the Digital Beam Former Test System commands. It is written for users who wish to conduct tests of the Digital Beam forming Test processor using the TCC. The document describes the function, use, and syntax of the TCC commands available to the user while summarizing and demonstrating the use of the commands wtihin DOS batch files.

  15. Simple Digital Control of a Two-Stage PFC Converter Using DSPIC30F Microprocessor

    DEFF Research Database (Denmark)

    Török, Lajos; Munk-Nielsen, Stig

    2010-01-01

    The use of dsPIC digital signal controllers (DSC) in Switch Mode Power Supply (SMPS) applications opens new perspectives for cheap and flexible digital control solutions. This paper presents the digital control of a two stage power factor corrector (PFC) converter. The PFC circuit is designed...... and built for 70W rated output power. Average current mode control for boost converter and current programmed control for forward converter are implemented on a dsPIC30F1010. Pulse Width Modulation (PWM) technique is used to drive the switching MOSFETs. Results show that digital solutions with ds...

  16. A standardized crisis management model for self-harming and suicidal individuals with three or more diagnostic criteria of borderline personality disorder: The Brief Admission Skane randomized controlled trial protocol (BASRCT)

    NARCIS (Netherlands)

    Liljedahl, S.I.; Helleman, M.; Daukantaite, D.; Westrin, A.; Westling, S.

    2017-01-01

    BACKGROUND: Brief Admission is a crisis and risk management strategy in which self-harming and suicidal individuals with three or more diagnostic criteria of borderline personality disorder self-admit to hospital at times of increasing risk when other efforts to stay safe are failing. Standardized

  17. Individual differences in self-reported self-control predict successful emotion regulation.

    Science.gov (United States)

    Paschke, Lena M; Dörfel, Denise; Steimke, Rosa; Trempler, Ima; Magrabi, Amadeus; Ludwig, Vera U; Schubert, Torsten; Stelzel, Christine; Walter, Henrik

    2016-08-01

    Both self-control and emotion regulation enable individuals to adapt to external circumstances and social contexts, and both are assumed to rely on the overlapping neural resources. Here, we tested whether high self-reported self-control is related to successful emotion regulation on the behavioral and neural level. One hundred eight participants completed three self-control questionnaires and regulated their negative emotions during functional magnetic resonance imaging using reappraisal (distancing). Trait self-control correlated positively with successful emotion regulation both subjectively and neurally, as indicated by online ratings of negative emotions and functional connectivity strength between the amygdala and prefrontal areas, respectively. This stronger overall connectivity of the left amygdala was related to more successful subjective emotion regulation. Comparing amygdala activity over time showed that high self-controllers successfully maintained down-regulation of the left amygdala over time, while low self-controllers failed to down-regulate towards the end of the experiment. This indicates that high self-controllers are better at maintaining a motivated state supporting emotion regulation over time. Our results support assumptions concerning a close relation of self-control and emotion regulation as two domains of behavioral control. They further indicate that individual differences in functional connectivity between task-related brain areas directly relate to differences in trait self-control. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  18. Digital control system of a steam generator water level by LQG optimal method

    International Nuclear Information System (INIS)

    Lee, Yoon Joon

    1993-01-01

    A digital control system for the steam generator water level control is developed using LQG optimal design method. To describe the more realistic situaton, a feedwater valve actuator is assumed to be of the first order lagger and is included in the overall control system. By composing the digital control circuit in such a way that the overall control system consists of two sub-systems of feedwater station and feedback loop digital controller, the design procedure is divided into two independent steps. The feedwater station system is described in the error dynamics of an ordinary regulator system. The optimal gains are obtained by LQ method which imposes the constraints of the feedwater valve motion as well as on the output deviations. Developed also is a Kalman observer on account of the flow measurement uncertainty at low power. Then a digital controller on the feedback loop is designed so that the system maintains the same stability margins for all power ranges. The simulation results show thst the optimal digital system has a good control characteristics despite the adverse dynamics of a steam generator at low power. (Author)

  19. Development and implementation of an automated quantitative film digitizer quality control program

    Science.gov (United States)

    Fetterly, Kenneth A.; Avula, Ramesh T. V.; Hangiandreou, Nicholas J.

    1999-05-01

    A semi-automated, quantitative film digitizer quality control program that is based on the computer analysis of the image data from a single digitized test film was developed. This program includes measurements of the geometric accuracy, optical density performance, signal to noise ratio, and presampled modulation transfer function. The variability of the measurements was less than plus or minus 5%. Measurements were made on a group of two clinical and two laboratory laser film digitizers during a trial period of approximately four months. Quality control limits were established based on clinical necessity, vendor specifications and digitizer performance. During the trial period, one of the digitizers failed the performance requirements and was corrected by calibration.

  20. Digital TV-echelle spectrograph for simultaneous multielemental analysis using microcomputer control

    International Nuclear Information System (INIS)

    Davidson, J.B.; Case, A.L.

    1980-12-01

    A digital TV-echelle spectrograph with microcomputer control was developed for simultaneous multielemental analysis. The optical system is a commercially available unit originally equipped for film and photomultiplier (single element) readout. The film port was adapted for the intensifier camera. The camera output is digitized and stored in a microcomputer-controlled, 512 x 512 x 12 bit memory and image processor. Multiple spectra over the range of 200 to 800 nm are recorded in a single exposure. Spectra lasting from nanoseconds to seconds are digitized and stored in 0.033 s and displayed on a TV monitor. An inexpensive microcomputer controls the exposure, reads and displays the intensity of predetermined spectral lines, and calculates wavelengths of unknown lines. The digital addresses of unknown lines are determined by superimposing a cursor on the TV display. The microcomputer also writes into memory wavelength fiducial marks for alignment of the TV camera

  1. Experience with digital instrumentation and control systems for CANDU power plant modifications

    International Nuclear Information System (INIS)

    Basu, S.

    1997-01-01

    Over the last years, Ontario Hydro CANDU power plants have gone through many modifications. This includes modification from analog hardwired controls to digital and solid state controls and replacement of the existing digital controls with the latest hardware and software technology. Examples of digital modifications at Bruce A and other CANDU power plants are briefly described and categorized. Most of the I and C technology development has been supported by the CANDU Owners Group (COG) a consortium of Canadian nuclear utilities and the Atomic Energy Canada Limited (AECL). (author)

  2. Experience with digital instrumentation and control systems for CANDU power plant modifications

    Energy Technology Data Exchange (ETDEWEB)

    Basu, S [Ontario Hydro, Toronto, ON (Canada)

    1997-07-01

    Over the last years, Ontario Hydro CANDU power plants have gone through many modifications. This includes modification from analog hardwired controls to digital and solid state controls and replacement of the existing digital controls with the latest hardware and software technology. Examples of digital modifications at Bruce A and other CANDU power plants are briefly described and categorized. Most of the I and C technology development has been supported by the CANDU Owners Group (COG) a consortium of Canadian nuclear utilities and the Atomic Energy Canada Limited (AECL). (author).

  3. Automation of extrusion of porous cable products based on a digital controller

    Science.gov (United States)

    Chostkovskii, B. K.; Mitroshin, V. N.

    2017-07-01

    This paper presents a new approach to designing an automated system for monitoring and controlling the process of applying porous insulation material on a conductive cable core, which is based on using structurally and parametrically optimized digital controllers of an arbitrary order instead of calculating typical PID controllers using known methods. The digital controller is clocked by signals from the clock length sensor of a measuring wheel, instead of a timer signal, and this provides the robust properties of the system with respect to the changing insulation speed. Digital controller parameters are tuned to provide the operating parameters of the manufactured cable using a simulation model of stochastic extrusion and are minimized by moving a regular simplex in the parameter space of the tuned controller.

  4. Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.

    Science.gov (United States)

    Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi

    2011-01-01

    Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.

  5. Digital control in Finnish power industry applications and some research and development activities

    International Nuclear Information System (INIS)

    Haapanen, P.; Winter, M.

    1986-01-01

    First applications of digital control systems in Finnish power plants stem from a few years time. There are at present in operation two conventional peat fuelled district heating power plants and two others are under construction. In existing nuclear power plants digital control systems are not used. Feasibility studies of a new fifth nuclear power plant have been carried out and also preliminary design exercises on its control systems has been done. It seems that the use of a digital control system in this plant is an alternative worthy of consideration. The existing digital control applications and future plans for their use in the Finnish power industry are described. The rest of the paper is devoted to the reliability questions. Software reliability is a new problem area emanating from the use of programmable digital systems. A description of a cooperative project on these questions between VTT and OECD Halden Project is given. VTT has also developed an interactive computer program, RELVEC, for plant and control system reliability analysis. The structure and use of this system is described

  6. Optimum image compression rate maintaining diagnostic image quality of digital intraoral radiographs

    International Nuclear Information System (INIS)

    Song, Ju Seop; Koh, Kwang Joon

    2000-01-01

    The aims of the present study are to determine the optimum compression rate in terms of file size reduction and diagnostic quality of the images after compression and evaluate the transmission speed of original or each compressed images. The material consisted of 24 extracted human premolars and molars. The occlusal surfaces and proximal surfaces of the teeth had a clinical disease spectrum that ranged from sound to varying degrees of fissure discoloration and cavitation. The images from Digora system were exported in TIFF and the images from conventional intraoral film were scanned and digitalized in TIFF by Nikon SF-200 scanner(Nikon, Japan). And six compression factors were chosen and applied on the basis of the results from a pilot study. The total number of images to be assessed were 336. Three radiologists assessed the occlusal and proximal surfaces of the teeth with 5-rank scale. Finally diagnosed as either sound or carious lesion by one expert oral pathologist. And sensitivity and specificity and kappa value for diagnostic agreement was calculated. Also the area (Az) values under the ROC curve were calculated and paired t-test and oneway ANOVA test was performed. Thereafter, transmission time of the image files of the each compression level were compared with that of the original image files. No significant difference was found between original and the corresponding images up to 7% (1:14) compression ratio for both the occlusal and proximal caries (p<0.05). JPEG3 (1:14) image files are transmitted fast more than 10 times, maintained diagnostic information in image, compared with original image files. 1:14 compressed image file may be used instead of the original image and reduce storage needs and transmission time.

  7. Comparison of Failure Analysis and Operating Experiences of Digital Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chan; Shin, Tae Young [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2014-08-15

    This study focuses on digital control systems that have the same functions but different designs. Some differences and common points between these two digital control systems are analyzed in terms of vulnerabilities in plant operation. In addition, this study confirms why unexpected outcomes can occur through a comparison of the system failure experiences with the analytic results of FMEA and FTA. This evaluation demonstrates that the digital system may have vulnerable components whose single failures can cause plant transients even if the system has a redundant structure according to its system design.

  8. Reduced optical transmission of SiO2 fibers used in controlled fusion diagnostics

    International Nuclear Information System (INIS)

    Ramsey, A.T.; Adler, H.G.; Hill, K.W.

    1993-02-01

    We have subjected a silica core fiber optic cable to 4 years of low-level neutron and gamma radiation from Princeton's TFTR controlled fusion experiment The accumulated dose was 200 Gy. As a result of the radiation, we have measured increased attenuations of 100--300 db/km in the visible part of the spectrum, and a decrease of the numerical aperture. An attempt to decrease this damage by photobleaching failed. We argue that this failure is not unexpected, since the rate of damage is so slow and the time scale so long that the self-annealing process keeps the residual damage at the irreducible level seen in other experiments. The implications of these findings for controlled fusion diagnostics during upcoming experiments with highly reactive deuterium-tritium plasmas are discussed

  9. Use of digital speech recognition in diagnostics radiology

    International Nuclear Information System (INIS)

    Arndt, H.; Stockheim, D.; Mutze, S.; Petersein, J.; Gregor, P.; Hamm, B.

    1999-01-01

    Purpose: Applicability and benefits of digital speech recognition in diagnostic radiology were tested using the speech recognition system SP 6000. Methods: The speech recognition system SP 6000 was integrated into the network of the institute and connected to the existing Radiological Information System (RIS). Three subjects used this system for writing 2305 findings from dictation. After the recognition process the date, length of dictation, time required for checking/correction, kind of examination and error rate were recorded for every dictation. With the same subjects, a correlation was performed with 625 conventionally written finding. Results: After an 1-hour initial training the average error rates were 8.4 to 13.3%. The first adaptation of the speech recognition system (after nine days) decreased the average error rates to 2.4 to 10.7% due to the ability of the program to learn. The 2 nd and 3 rd adaptations resulted only in small changes of the error rate. An individual comparison of the error rate developments in the same kind of investigation showed the relative independence of the error rate on the individual user. Conclusion: The results show that the speech recognition system SP 6000 can be evaluated as an advantageous alternative for quickly recording radiological findings. A comparison between manually writing and dictating the findings verifies the individual differences of the writing speeds and shows the advantage of the application of voice recognition when faced with normal keyboard performance. (orig.) [de

  10. Design for the human-machine interface of a digitalized reactor control-room

    International Nuclear Information System (INIS)

    Qu Ronghong; Zhang Liangju; Li Duo; Yu Hui

    2005-01-01

    Digitalized technology is implemented in the instrumentation and control system of an in-construction research reactor, which advances information display in both contents and styles in a nuclear reactor control-room, and greatly improves human-machine interface. In the design for a digitalized nuclear reactor control-room there are a series of new problems and technologies should be considered seriously. This paper mainly introduces the design for the digitalized control-room of the research nuclear reactor and covered topics include design principle of human-machine interface, organization and classification of interface graphics, technologies and principles based on human factors engineering and implemented in the graphics design. (authors)

  11. Adaptive robust pole-placement control of 4-leg voltage-source inverters for standalone photovoltaic systems: Considering digital delays

    International Nuclear Information System (INIS)

    Nasiri, Reza; Radan, Ahmad

    2011-01-01

    Three leg inverters for photovoltaic systems have a lot of disadvantages, especially when the load is unbalanced. These disadvantages are for example, small utilization of the DC link voltage, the dependency of the modulation factor of the load current and the superposition of a DC component with the output AC voltage. A solution for these problems is the 4-leg inverter. Most papers dealing with 4-leg inverters ignore the effect of digital delays in control loop and suggest classic controllers, such as PI controller. However, the transient performance of the system does not become adjustable by applying classic control techniques. Additionally, adaptive control techniques have not yet been discussed for 4-leg inverters. This paper proposes the pole-placement control strategy via state feedback with integral state, which is a modern control technique, to control the system. Consequently, resulted system becomes highly robust. In addition, it suggests a Self-Tuner Regulator to guarantee the adaptive performance of the final system. Moreover, it proposes a novel model, considering digital delays, for 4-leg inverters. Simulation results show that transient performance of the system becomes accurately adjustable and the 4-leg inverter generates balanced voltage, with sinusoidal waveform, in spite of the presence of RL time variant loads.

  12. Overview of MFTF supervisory control and diagnostics system software

    International Nuclear Information System (INIS)

    Ng, W.C.

    1979-01-01

    The Mirror Fusion Test Facility (MFTF) at the Lawrence Livermore Laboratory (LLL) is currently the largest mirror fusion research project in the world. Its Control and Diagnostics System is handled by a distributed computer network consisting of nine Interdata minicomputer systems and about 65 microprocessors. One of the design requirements is tolerance of single-point failure. If one of the computer systems becomes inoperative, the experiment can still be carried out, although the system responsiveness to operator command may be degraded. In a normal experiment cycle, the researcher can examine the result of the previous experiment, change any control parameter, fire a shot, collect four million bytes of diagnostics data, perform intershot analysis, and have the result presented - all within five minutes. The software approach adopted for the Supervisory Control and Diagnostics System features chief programmer teams and structured programming. Pascal is the standard programming language in this project

  13. Multispectral Video-Microscope Modified for Skin Diagnostics

    Directory of Open Access Journals (Sweden)

    Rubins U.

    2014-12-01

    Full Text Available Commercial DinoLite AD413 digital microscope was modified for skin diagnostics purposes. The original LED ring (4 white and 4 ultraviolet light emitters of microscope was replaced by a custom-designed 16-LED ring module consisting of four LED groups (450, 545, 660 and 940 nm, and an onboard LED controller with USB hub was added. The video acquisition and LED switching are performed using custom-designed Matlab software which provides real-time spectral analysis of multi-spectral images and calculation of skin chromophore optical density. The developed multispectral video-microscope is mainly meant for diagnostics of skin malformations, e.g. skin cancerous lesions.

  14. Nuclear Energy Research Initiative (NERI): On-Line Intelligent Self-Diagnostic Monitoring for Next Generation Nuclear Plants - Phase I Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    L. J. Bond; S. R. Doctor; R. W. Gilbert; D. B. Jarrell; F. L. Greitzer; R. J. Meador

    2000-09-01

    OAK-B135 This OSTI ID belongs to an IWO and is being released out of the system. The Program Manager Rebecca Richardson has confirmed that all reports have been received. The objective of this project is to design and demonstrate the operation of the real-time intelligent self-diagnostic and prognostic system for next generation nuclear power plant systems. This new self-diagnostic technology is titled, ''On-Line Intelligent Self-Diagnostic Monitoring System'' (SDMS). This project provides a proof-of-principle technology demonstration for SDMS on a pilot plant scale service water system, where a distributed array of sensors is integrated with active components and passive structures typical of next generation nuclear power reactor and plant systems. This project employs state-of-the-art sensors, instrumentation, and computer processing to improve the monitoring and assessment of the power reactor system and to provide diagnostic and automated prognostics capabilities.

  15. Digital computer control of a research nuclear reactor

    International Nuclear Information System (INIS)

    Crawford, Kevan

    1986-01-01

    Currently, the use of digital computers in energy producing systems has been limited to data acquisition functions. These computers have greatly reduced human involvement in the moment to moment decision process and the crisis decision process, thereby improving the safety of the dynamic energy producing systems. However, in addition to data acquisition, control of energy producing systems also includes data comparison, decision making, and control actions. The majority of the later functions are accomplished through the use of analog computers in a distributed configuration. The lack of cooperation and hence, inefficiency in distributed control, and the extent of human interaction in critical phases of control have provided the incentive to improve the later three functions of energy systems control. Properly applied, centralized control by digital computers can increase efficiency by making the system react as a single unit and by implementing efficient power changes to match demand. Additionally, safety will be improved by further limiting human involvement to action only in the case of a failure of the centralized control system. This paper presents a hardware and software design for the centralized control of a research nuclear reactor by a digital computer. Current nuclear reactor control philosophies which include redundancy, inherent safety in failure, and conservative yet operational scram initiation were used as the bases of the design. The control philosophies were applied to the power monitoring system, the fuel temperature monitoring system, the area radiation monitoring system, and the overall system interaction. Unlike the single function analog computers that are currently used to control research and commercial reactors, this system will be driven by a multifunction digital computer. Specifically, the system will perform control rod movements to conform with operator requests, automatically log the required physical parameters during reactor

  16. Control theory of digitally networked dynamic systems

    CERN Document Server

    Lunze, Jan

    2013-01-01

    The book gives an introduction to networked control systems and describes new modeling paradigms, analysis methods for event-driven, digitally networked systems, and design methods for distributed estimation and control. Networked model predictive control is developed as a means to tolerate time delays and packet loss brought about by the communication network. In event-based control the traditional periodic sampling is replaced by state-dependent triggering schemes. Novel methods for multi-agent systems ensure complete or clustered synchrony of agents with identical or with individual dynamic

  17. Negative Peer Relationships on Piracy Behavior: A Cross-Sectional Study of the Associations between Cyberbullying Involvement and Digital Piracy

    Science.gov (United States)

    Yubero, Santiago; Larrañaga, Elisa; Villora, Beatriz

    2017-01-01

    The present study examines the relationship between different roles in cyberbullying behaviors (cyberbullies, cybervictims, cyberbullies-victims, and uninvolved) and self-reported digital piracy. In a region of central Spain, 643 (49.3% females, 50.7% males) students (grades 7–10) completed a number of self-reported measures, including cyberbullying victimization and perpetration, self-reported digital piracy, ethical considerations of digital piracy, time spent on the Internet, and leisure activities related with digital content. The results of a series of hierarchical multiple regression models for the whole sample indicate that cyberbullies and cyberbullies-victims are associated with more reports of digital piracy. Subsequent hierarchical multiple regression analyses, done separately for males and females, indicate that the relationship between cyberbullying and self-reported digital piracy is sustained only for males. The ANCOVA analysis show that, after controlling for gender, self-reported digital piracy and time spent on the Internet, cyberbullies and cyberbullies-victims believe that digital piracy is a more ethically and morally acceptable behavior than victims and uninvolved adolescents believe. The results provide insight into the association between two deviant behaviors. PMID:28981466

  18. Negative Peer Relationships on Piracy Behavior: A Cross-Sectional Study of the Associations between Cyberbullying Involvement and Digital Piracy.

    Science.gov (United States)

    Yubero, Santiago; Larrañaga, Elisa; Villora, Beatriz; Navarro, Raúl

    2017-10-05

    The present study examines the relationship between different roles in cyberbullying behaviors (cyberbullies, cybervictims, cyberbullies-victims, and uninvolved) and self-reported digital piracy. In a region of central Spain, 643 (49.3% females, 50.7% males) students (grades 7-10) completed a number of self-reported measures, including cyberbullying victimization and perpetration, self-reported digital piracy, ethical considerations of digital piracy, time spent on the Internet, and leisure activities related with digital content. The results of a series of hierarchical multiple regression models for the whole sample indicate that cyberbullies and cyberbullies-victims are associated with more reports of digital piracy. Subsequent hierarchical multiple regression analyses, done separately for males and females, indicate that the relationship between cyberbullying and self-reported digital piracy is sustained only for males. The ANCOVA analysis show that, after controlling for gender, self-reported digital piracy and time spent on the Internet, cyberbullies and cyberbullies-victims believe that digital piracy is a more ethically and morally acceptable behavior than victims and uninvolved adolescents believe. The results provide insight into the association between two deviant behaviors.

  19. Resolution enhancement in digital holography by self-extrapolation of holograms.

    Science.gov (United States)

    Latychevskaia, Tatiana; Fink, Hans-Werner

    2013-03-25

    It is generally believed that the resolution in digital holography is limited by the size of the captured holographic record. Here, we present a method to circumvent this limit by self-extrapolating experimental holograms beyond the area that is actually captured. This is done by first padding the surroundings of the hologram and then conducting an iterative reconstruction procedure. The wavefront beyond the experimentally detected area is thus retrieved and the hologram reconstruction shows enhanced resolution. To demonstrate the power of this concept, we apply it to simulated as well as experimental holograms.

  20. Dermoscopy, Digital Dermoscopy and Other Diagnostic Tools in the Early Detection of Melanoma and Follow-up of High-risk Skin Cancer Patients.

    Science.gov (United States)

    Thomas, Luc; Puig, Susana

    2017-07-05

    Early detection is a key strategy for reducing the mortality and economic burden associated with melanoma. Dermoscopy is a non-invasive and cost-effective tool for melanoma diagnosis, which has been shown to be a reliable and sensitive method for detecting early-stage skin cancer and reducing the number of unnecessary excisions. Patients at high risk of developing melanoma require long-term surveillance. Use of digital dermoscopy follow-up of these patients has led to improved outcomes. Combined follow-up programmes using total-body photography and digital dermoscopy have led to further improvements in early diagnosis and diagnostic accuracy. Dermoscopy is now widely used by dermatologists, but the public health impact of this tool is yet to be evaluated. Despite the clear advantages of dermoscopy and digital follow-up meth-ods, dermoscopy training and access to digital dermoscopy among dermatologists and general practitioners needs to be improved.

  1. Supervisory Control and Diagnostics System Distributed Operating System

    International Nuclear Information System (INIS)

    McGoldrick, P.R.

    1979-01-01

    This paper contains a description of the Supervisory Control and Diagnostics System (SCDS) Distributed Operating System. The SCDS consists of nine 32-bit minicomputers with shared memory. The system's main purpose is to control a large Mirror Fusion Test Facility

  2. Self-diagnosis of malaria by travelers and expatriates: assessment of malaria rapid diagnostic tests available on the internet.

    Science.gov (United States)

    Maltha, Jessica; Gillet, Philippe; Heutmekers, Marloes; Bottieau, Emmanuel; Van Gompel, Alfons; Jacobs, Jan

    2013-01-01

    In the past malaria rapid diagnostic tests (RDTs) for self-diagnosis by travelers were considered suboptimal due to poor performance. Nowadays RDTs for self-diagnosis are marketed and available through the internet. The present study assessed RDT products marketed for self-diagnosis for diagnostic accuracy and quality of labeling, content and instructions for use (IFU). Diagnostic accuracy of eight RDT products was assessed with a panel of stored whole blood samples comprising the four Plasmodium species (n = 90) as well as Plasmodium negative samples (n = 10). IFUs were assessed for quality of description of procedure and interpretation and for lay-out and readability level. Errors in packaging and content were recorded. Two products gave false-positive test lines in 70% and 80% of Plasmodium negative samples, precluding their use. Of the remaining products, 4/6 had good to excellent sensitivity for the diagnosis of Plasmodium falciparum (98.2%-100.0%) and Plasmodium vivax (93.3%-100.0%). Sensitivity for Plasmodium ovale and Plasmodium malariae diagnosis was poor (6.7%-80.0%). All but one product yielded false-positive test lines after reading beyond the recommended reading time. Problems with labeling (not specifying target antigens (n = 3), and content (desiccant with no humidity indicator (n = 6)) were observed. IFUs had major shortcomings in description of test procedure and interpretation, poor readability and lay-out and user-unfriendly typography. Strategic issues (e.g. the need for repeat testing and reasons for false-negative tests) were not addressed in any of the IFUs. Diagnostic accuracy of RDTs for self-diagnosis was variable, with only 4/8 RDT products being reliable for the diagnosis of P. falciparum and P. vivax, and none for P. ovale and P. malariae. RDTs for self-diagnosis need improvements in IFUs (content and user-friendliness), labeling and content before they can be considered for self-diagnosis by the traveler.

  3. Digital control for turbogas units; Control digital para unidades turbogas

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Beltran, Carlos Daniel

    1997-02-01

    The present thesis deals with the rehabilitation of the control system for the gas turbines W501 of the Gomez Palacio Combined Cycle Power Station in the state of Durango, Mexico. The first part of the development deals with a re-engineering process of software applied to the digital control system of the gas turbines of the Gomez Palacio Combined Cycle Power Station. This process was developed using concepts of several branches of engineering: a) involved the knowledge of the software engineering, using formal methods for the analysis of the original system and the redesign of the new system; b) The control engineering was used in the analysis of diverse control and automation strategies employed for gas turbines control, with the objective of verifying the type of instructions and existing routines within the software. The final product of this stage is a modulated programmatic system, based on structured design that is functionally a mirror image of the original system. The system obtained conformed by five main modules which are based on a model proposed originally for control by batch: i) Man Machine Interface, ii) Regulatory Control, iii) Protections, iv) Logic sequences and v) Supervision. The second stage of development was the improvement of the speed control of the turbine. When a turbogas unit is controlled, it must be taken into account several operation stages such as the starting, the control in stable state and the shut down. The real behavior of the turbine during the starting, and mainly the great number of backward movements produced, proposed by itself the search of a new controller who more closely maintained the acceleration specifications whereupon the turbine was designed. The development of a new control algorithm began with the analysis of the process, trying to identify which are the critical stages of this one and be able to evaluate in an objective form the advantages of an algorithm upon the other. It was continued with the

  4. Quasiinvariant Automatic Control Digital Systems of Inertia Objects

    OpenAIRE

    Lvov, Volodymyr; Andrieiev, Anatoliy

    2010-01-01

    The two-connected automatic control digital system (ACDS) and system of ACDS with combined control are examined. The two-connected and combined system of ACDS with work in the mode of tracking and stabilizing are analyzed. The discrete transfer function of two-connected and combined systems are obtained.

  5. Process management and controlling in diagnostic radiology

    International Nuclear Information System (INIS)

    Gocke, P.; Debatin, J.F.; Duerselen, L.F.J.

    2002-01-01

    Systematic process management and efficient quality control is rapidly gaining importance in our healthcare system. What does this mean for diagnostic radiology departments?To improve efficiency, quality and productivity the workflow within the department of diagnostic and interventional radiology at the University Hospital of Essen were restructured over the last two years. Furthermore, a controlling system was established. One of the pursued aims was to create a quality management system as a basis for the subsequent certification according to the ISO EN 9001:2000 norm.Central to the success of the workflow reorganisation was the training of selected members of the department's staff in process and quality management theory. Thereafter, a dedicated working group was created to prepare the reorganisation and the subsequent ISO certification with the support of a consulting partner. To assure a smooth implementation of the restructured workflow and create acceptance for the required ISO-9001 documentation, the entire staff was familiarized with the basic ideas of process- and quality-management in several training sessions.This manuscript summarizes the basic concepts of process and quality management as they were taught to our staff. A direct relationship towards diagnostic radiology is maintained throughout the text. (orig.) [de

  6. Methods of digital image processing

    International Nuclear Information System (INIS)

    Doeler, W.

    1985-01-01

    Increasing use of computerized methods for diagnostical imaging of radiological problems will open up a wide field of applications for digital image processing. The requirements set by routine diagnostics in medical radiology point to picture data storage and documentation and communication as the main points of interest for application of digital image processing. As to the purely radiological problems, the value of digital image processing is to be sought in the improved interpretability of the image information in those cases where the expert's experience and image interpretation by human visual capacities do not suffice. There are many other domains of imaging in medical physics where digital image processing and evaluation is very useful. The paper reviews the various methods available for a variety of problem solutions, and explains the hardware available for the tasks discussed. (orig.) [de

  7. Alcohol self-control behaviors of adolescents.

    Science.gov (United States)

    Glassman, Tavis; Werch, Chudley Chad; Jobli, Edessa

    2007-03-01

    The aims of the present study were to: (1) factor analyze a 13-item adolescent alcohol self-control behavior scale, (2) examine associations between frequency of self-control behavior use and alcohol consumption, and (3) to determine which self-control behaviors best predict alcohol use and consequences. A confidential standardized survey was used to collect data on participant's 30-day frequency, quantity, and heavy use of alcohol; alcohol-related consequences; and alcohol self-control behaviors. A principal component factor analysis produced the following three components: Healthy Alternatives (alpha=.81), Self-regulation (alpha=.72), and Assertive Communication (alpha=.73). MANOVAs indicated strong associations between frequency of use of the three types of self-control behaviors and alcohol consumption (p valuesadolescents, followed by Healthy Alternatives.

  8. Dynamic self-cleaning in gecko setae via digital hyperextension

    Science.gov (United States)

    Hu, Shihao; Lopez, Stephanie; Niewiarowski, Peter H.; Xia, Zhenhai

    2012-01-01

    Gecko toe pads show strong adhesion on various surfaces yet remain remarkably clean around everyday contaminants. An understanding of how geckos clean their toe pads while being in motion is essential for the elucidation of animal behaviours as well as the design of biomimetic devices with optimal performance. Here, we test the self-cleaning of geckos during locomotion. We provide, to our knowledge, the first evidence that geckos clean their feet through a unique dynamic self-cleaning mechanism via digital hyperextension. When walking naturally with hyperextension, geckos shed dirt from their toes twice as fast as they would if walking without hyperextension, returning their feet to nearly 80 per cent of their original stickiness in only four steps. Our dynamic model predicts that when setae suddenly release from the attached substrate, they generate enough inertial force to dislodge dirt particles from the attached spatulae. The predicted cleaning force on dirt particles significantly increases when the dynamic effect is included. The extraordinary design of gecko toe pads perfectly combines dynamic self-cleaning with repeated attachment/detachment, making gecko feet sticky yet clean. This work thus provides a new mechanism to be considered for biomimetic design of highly reuseable and reliable dry adhesives and devices. PMID:22696482

  9. Characterization of microcalcification: can digital monitor zooming replace magnification mammography in full-field digital mammography?

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun-Kyung; Kwak, Jin Young; Son, Eun Ju; Youk, Ji Hyun; Choi, Seon Hyeong; Oh, Ki Keun; Han, Mooyoung

    2009-01-01

    The aim of this study was to compare the diagnostic accuracy and image quality of microcalcifications in zoomed digital contact mammography with digital magnification mammography. Three radiologists with different levels of experience in mammography reviewed 120 microcalcification clusters in 111 patients with a full-field digital mammography system relying on digital magnification mammogram (MAG) images and zoomed images from contact mammography (ZOOM) using commercially available zooming systems on monitors. Each radiologist estimated the probability of malignancy and rated the image quality and confidence rate. Performance was evaluated by sensitivity, specificity, positive predictive value, negative predictive value, and receiver operating characteristic (ROC) analysis. All three radiologists rated MAG images higher than ZOOM images for sensitivity with statistical significance (average value, 92% vs. 87%, P<0.05) and performance by ROC analysis improved with MAG imaging. The confidence rate for diagnosis decision and the assessment of lesion characteristics were also better in MAG images than in ZOOM images with statistical significance (P<0.0001). Digital magnification mammography can enhance diagnostic performance when characterizing microcalcifications. Images zoomed from digital contact mammography cannot serve as an alternative to direct magnification digital mammography. (orig.)

  10. The role of neural networks in reactor diagnostics and control

    International Nuclear Information System (INIS)

    Pazsit, I.; Kitamura, M.

    1997-01-01

    Reactor diagnostics and core diagnostics in particular, is an inverse task, just as most other diagnostics. One measures some physical parameter at some position, or the fluctuation thereof, which is given rise by the fluctuation of another parameter, presumably at a different position. In neutron noise diagnostics, the measured quantity is the neutron noise, whereas the cause, fluctuations of the core material, is called the open-quotes noise sourceclose quotes. The relationship between the cause (noise source) and the induced noise (effect) is determined by the physics of the process and can usually be described by a theory. This means that the direct task, calculation of the noise from the noise source, can always be achieved. In diagnostics, however, the process starts from the back end, i.e. one observes the effect of some cause. The task is to infer the cause (noise source) from the effect (induced noise), which is an inverse task (sometimes also called unfolding). The situation is very much similar even regarding control problems. The system state is described by a vector in the parameter space. When it deviates from the desired one, the control parameters need to be changed to bring the system into the desired state. The computation of the change in the state vector, due to a change in the control vector, can be calculated with no difficulty in principle. The control requires however the inverse task to be performed, i.e. to determine which changes of the control vector would bring the state vector into the desired state

  11. New kind of user interface for controlling MFTF diagnostics

    International Nuclear Information System (INIS)

    Preckshot, G.G.; Saroyan, R.A.; Mead, J.E.

    1983-01-01

    The Mirror Fusion Test Facility (MFTF) at Lawrence Livermore National Laboratory is faced with the problem of controlling a multitude of plasma diagnostics instruments from a central, multiprocessor computer facility. A 16-bit microprocessor-based workstation allows each physicist entree into the central multiprocessor, which consists of nine Perkin-Elmer 32-bit minicomputers. The workstation provides the user interface to the larger system, with display graphics, windowing, and a physics notebook. Controlling a diagnostic is now equivalent to making entries into a traditional physics notebook

  12. Event-driven control of a speed varying digital displacement machine

    DEFF Research Database (Denmark)

    Pedersen, Niels Henrik; Johansen, Per; Andersen, Torben O.

    2017-01-01

    . The controller synthesis is carried out as a discrete optimal deterministic problem with full state feedback. Based on a linear analysis of the feedback control system, stability is proven in a pre-specified operation region. Simulation of a non-linear evaluation model with the controller implemented shows great...... be treated as a Discrete Linear Time Invariant control problem with synchronous sampling rate. To make synchronous linear control theory applicable for a variable speed digital displacement machine, a method based on event-driven control is presented. Using this method, the time domain differential equations...... are converted into the spatial (position) domain to obtain a constant sampling rate and thus allowing for use of classical control theory. The method is applied to a down scaled digital fluid power motor, where the motor speed is controlled at varying references under varying pressure and load torque conditions...

  13. NETWORK SERVICES FOR DIAGNOSTIC OPTODIGITAL COMPLEX FOR TELEMEDICINE

    Directory of Open Access Journals (Sweden)

    D. S. Kopylov

    2014-03-01

    Full Text Available The paper deals with a result of the network services development for the optodigital complex for telemedicine diagnostics. This complex is designed for laboratory and clinical tests in health care facilities. Composition of network services includes the following: a client application for database of diagnostic test, a web-service, a web interface, a video server and microimage processing server. Structure of these services makes it possible to combine set of software for transferring depersonalized medical data via the Internet and operating with optodigital devices included in the complex. Complex is consisted of three systems: micro-vision, endoscopic and network. The micro-vision system includes an automated digital microscope with two highly sensitive cameras which can be controlled remotely via the Internet. The endoscopic system gives the possibility to implement video broadcasting to remote users both during diagnostic tests and also off-line after tests. The network system is the core of the complex where network services and application software are functioning, intended for archiving, storage and providing access to the database of diagnostic tests. The following subjects are developed and tested for functional stability: states transfer protocol, commands transfer protocol and video-stream transfer protocol from automated digital microscope and video endoscope. These protocols can work in web browsers on modern mobile devices without additional software.

  14. Digital chest radiography: an update on modern technology, dose containment and control of image quality

    International Nuclear Information System (INIS)

    Schaefer-Prokop, Cornelia; Venema, Henk W.; Neitzel, Ulrich; Uffmann, Martin; Prokop, Mathias

    2008-01-01

    The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems. (orig.)

  15. Application of MATLAB in testing digital power supply controllers

    International Nuclear Information System (INIS)

    Ke Xinhua; Chinese Academy of Sciences, Beijing; Lu Songlin; Shen Tianjian

    2008-01-01

    Based on introducing MATLAB SISOTOOL in MATLAB control box and the magnet power supply system in detail, this paper presented the application of MATLAB SISOTOOL in Testing Digital Power Supply controllers. This control tool should be popularized because of its characteristics of convenience and easy-to-use. (authors)

  16. Test Platform for Advanced Digital Control of Brushless DC Motors (MSFC Center Director's Discretionary Fund)

    Science.gov (United States)

    Gwaltney, D. A.

    2002-01-01

    A FY 2001 Center Director's Discretionary Fund task to develop a test platform for the development, implementation. and evaluation of adaptive and other advanced control techniques for brushless DC (BLDC) motor-driven mechanisms is described. Important applications for BLDC motor-driven mechanisms are the translation of specimens in microgravity experiments and electromechanical actuation of nozzle and fuel valves in propulsion systems. Motor-driven aerocontrol surfaces are also being utilized in developmental X vehicles. The experimental test platform employs a linear translation stage that is mounted vertically and driven by a BLDC motor. Control approaches are implemented on a digital signal processor-based controller for real-time, closed-loop control of the stage carriage position. The goal of the effort is to explore the application of advanced control approaches that can enhance the performance of a motor-driven actuator over the performance obtained using linear control approaches with fixed gains. Adaptive controllers utilizing an exact model knowledge controller and a self-tuning controller are implemented and the control system performance is illustrated through the presentation of experimental results.

  17. Digital control rod blocking monitor

    International Nuclear Information System (INIS)

    Funayama, Yoshio.

    1996-01-01

    The present invention system is used for monitoring of a power region of a reactor, and used for monitoring of simultaneous withdrawal of a plurality of control rods without increasing the size or complicating the system. Namely, the system processes signals from a neutron flux detectors at the periphery of control rods controlled for withdrawal. As a result of the processing, the digital monitoring system generates an alarm when the reactor power at the periphery of the control rods fluctuates exceeding an allowable range. In the system, a control rod information forming means prepares frame data comprising front data, positions of the control rods to be withdrawn, frame numbers and completion data. A serial data transmitting means transmits the frame data successively as repeating frame data rows. A control rod information receiving means takes up the frame data of each of control rods to be withdrawn from the transmitted frame data rows. Since the system of the present invention can monitor the withdrawal of a plurality of control rods simultaneously without increasing the size or complicating the system, cost can be saved and the maintenance can be improved. (I.S.)

  18. Real-time digital control, data acquisition, and analysis system for the DIII-D multipulse Thomson scattering diagnostic

    International Nuclear Information System (INIS)

    Greenfield, C.M.; Campbell, G.L.; Carlstrom, T.N.; DeBoo, J.C.; Hsieh, C.; Snider, R.T.; Trost, P.K.

    1990-01-01

    A VME-based real-time computer system for laser control, data acquisition, and analysis for the DIII-D multipulse Thomson scattering diagnostic is described. The laser control task requires precise timing of up to eight Nd:YAG lasers, each with an average firing rate of 20 Hz. A cpu module in a real-time multiprocessing computer system will operate the lasers with evenly staggered laser pulses or in a ''burst mode,'' where all available (fully charged) lasers can be fired at 50--100 μs intervals upon receipt of an external event trigger signal. One or more cpu modules, along with a LeCroy FERA (fast encoding and readout ADC) system, will perform real-time data acquisition and analysis. Partial electron temperature and density profiles will be available for plasma feedback control within 1 ms following each laser pulse. The VME-based computer system consists of two or more target processor modules (25 MHz Motorola 68030) running the VMEexec real-time operating system connected to a Unix-based host system (also a 68030). All real-time software is fully interrupt driven to maximize system efficiency. Operator interaction and (non-real-time) data analysis takes place on a MicroVAX 3400 connected via DECnet

  19. Centralized digital control of accelerators

    International Nuclear Information System (INIS)

    Melen, R.E.

    1983-09-01

    In contrasting the title of this paper with a second paper to be presented at this conference entitled Distributed Digital Control of Accelerators, a potential reader might be led to believe that this paper will focus on systems whose computing intelligence is centered in one or more computers in a centralized location. Instead, this paper will describe the architectural evolution of SLAC's computer based accelerator control systems with respect to the distribution of their intelligence. However, the use of the word centralized in the title is appropriate because these systems are based on the use of centralized large and computationally powerful processors that are typically supported by networks of smaller distributed processors

  20. Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.

    Science.gov (United States)

    Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David

    1989-05-01

    The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.

  1. Dysfunction of Self-Regulation and Self-Control in Facebook Addiction.

    Science.gov (United States)

    Błachnio, Agata; Przepiorka, Aneta

    2016-09-01

    Nowadays, Facebook has become one of the most popular communication tools. With its increasing popularity, a new phenomenon connected with extensive use has appeared: namely, Facebook intrusion. The answer to the question of who is prone to become addicted still remains open. This study aimed to explore whether insufficient self-control and self-regulation resources in Facebook users are related to Facebook addiction. The participants in the study were 284 people. The Facebook Intrusion Questionnaire, the Brief Self-Control Scale, the Self-Regulation Scale, Action Control Scale, and the Multitasking Scale were used. We found that dysfunctional self-control system can be related to Facebook addiction. An insufficient self-control and low level of failure-related action orientation are those psychological characteristics that put Facebook users "at-risk" of Facebook addiction. The study reveals a picture showing that those Facebook users who are able to resist an impulse or temptation, are more self-disciplined, and do not focus on negative emotions are less likely to develop Facebook addiction. The obtained findings may serve as a basis for prevention programs for people at risk of Facebook addiction.

  2. ATCA digital controller hardware for vertical stabilization of plasmas in tokamaks

    International Nuclear Information System (INIS)

    Batista, A. J. N.; Sousa, J.; Varandas, C. A. F.

    2006-01-01

    The efficient vertical stabilization (VS) of plasmas in tokamaks requires a fast reaction of the VS controller, for example, after detection of edge localized modes (ELM). For controlling the effects of very large ELMs a new digital control hardware, based on the Advanced Telecommunications Computing Architecture trade mark sign (ATCA), is being developed aiming to reduce the VS digital control loop cycle (down to an optimal value of 10 μs) and improve the algorithm performance. The system has 1 ATCA trade mark sign processor module and up to 12 ATCA trade mark sign control modules, each one with 32 analog input channels (12 bit resolution), 4 analog output channels (12 bit resolution), and 8 digital input/output channels. The Aurora trade mark sign and PCI Express trade mark sign communication protocols will be used for data transport, between modules, with expected latencies below 2 μs. Control algorithms are implemented on a ix86 based processor with 6 Gflops and on field programmable gate arrays with 80 GMACS, interconnected by serial gigabit links in a full mesh topology

  3. Distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A real-time multi-tasking digital control system with rapid recovery capability is disclosed. The control system includes a plurality of computing units comprising a plurality of redundant processing units, with each of the processing units configured to generate one or more redundant control commands. One or more internal monitors are employed for detecting data errors in the control commands. One or more recovery triggers are provided for initiating rapid recovery of a processing unit if data errors are detected. The control system also includes a plurality of actuator control units each in operative communication with the computing units. The actuator control units are configured to initiate a rapid recovery if data errors are detected in one or more of the processing units. A plurality of smart actuators communicates with the actuator control units, and a plurality of redundant sensors communicates with the computing units.

  4. Digital Platforms as Factor Transforming Management Models in Businesses and Industries

    Science.gov (United States)

    Dimitrakiev, D.; Molodchik, A. V.

    2018-05-01

    Increasingly, digital platforms are built into the value chain, acting as an intermediary between the manufacturer and the consumer. The paper presents tendencies and features of business model transformation in connection with management of the new digital technologies. The limitations of traditional business models and the capabilities of business models based on digital platforms and self-organization were revealed. In the study, the viability of the new business model for the dental industry was confirmed and the new concept of the branch self-organizing control system based on the information platform, blockchain, cryptocurrency and reward of target consumer is offered, including mechanisms that make the model attractive for both the consumer and the service provider.

  5. Track: A randomized controlled trial of a digital health obesity treatment intervention for medically vulnerable primary care patients.

    Science.gov (United States)

    Foley, Perry; Steinberg, Dori; Levine, Erica; Askew, Sandy; Batch, Bryan C; Puleo, Elaine M; Svetkey, Laura P; Bosworth, Hayden B; DeVries, Abigail; Miranda, Heather; Bennett, Gary G

    2016-05-01

    Obesity continues to disproportionately affect medically vulnerable populations. Digital health interventions may be effective for delivering obesity treatment in low-resource primary care settings. Track is a 12-month randomized controlled trial of a digital health weight loss intervention in a community health center system. Participants are 351 obese men and women aged 21 to 65years with an obesity-related comorbidity. Track participants are randomized to usual primary care or to a 12-month intervention consisting of algorithm-generated tailored behavior change goals, self-monitoring via mobile technologies, daily self-weighing using a network-connected scale, skills training materials, 18 counseling phone calls with a Track coach, and primary care provider counseling. Participants are followed over 12months, with study visits at baseline, 6, and 12months. Anthropometric data, blood pressure, fasting lipids, glucose and HbA1C and self-administered surveys are collected. Follow-up data will be collected from the medical record at 24months. Participants are 68% female and on average 50.7years old with a mean BMI of 35.9kg/m(2). Participants are mainly black (54%) or white (33%); 12.5% are Hispanic. Participants are mostly employed and low-income. Over 20% of the sample has hypertension, diabetes and hyperlipidemia. Almost 27% of participants currently smoke and almost 20% score above the clinical threshold for depression. Track utilizes an innovative, digital health approach to reduce obesity and chronic disease risk among medically vulnerable adults in the primary care setting. Baseline characteristics reflect a socioeconomically disadvantaged, high-risk patient population in need of evidence-based obesity treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Analysis and improvement of digital control stability for master-slave manipulator system

    International Nuclear Information System (INIS)

    Yoshida, Koichi; Yabuta, Tetsuro

    1992-01-01

    Some bilateral controls of master-slave system have been designed, which can realize high-fidelity telemanipulation as if the operator were manipulating the object directly. While usual robot systems are controlled by software-servo system using digital computer, little work has been published on design and analysis for digital control of these systems, which must consider time-delay of sensor signals and zero order hold effect of command signals on actuators. This paper presents a digital control analysis for single degree of freedom master-slave system including impedance models of both the human operator and the task object, which clarifies some index for the stability. The stability result shows a virtual master-slave system concepts, which improve the digital control stability. We first analyze a dynamic control method of master-slave system in discrete-time system for the stability problem, which can realize high-fidelity telemanipulation in the continuous-time. Secondly, using the results of the stability analysis, the robust control scheme for master-slave system is proposed, and the validity of this scheme is finally confirmed by the simulation. Consequently, it would be considered that any combination of master and slave modules with dynamic model of these manipulators is possible to construct the stable master-slave system. (author)

  7. Digitally controlled twelve-pulse firing generator

    International Nuclear Information System (INIS)

    Berde, D.; Ferrara, A.A.

    1981-01-01

    Control System Studies for the Tokamak Fusion Test Reactor (TFTR) indicate that accurate thyristor firing in the AC-to-DC conversion system is required in order to achieve good regulation of the various field currents. Rapid update and exact firing angle control are required to avoid instabilities, large eddy currents, or parasitic oscillations. The Prototype Firing Generator was designed to satisfy these requirements. To achieve the required /plus or minus/0.77/degree/firing accuracy, a three-phase-locked loop reference was designed; otherwise, the Firing Generator employs digital circuitry. The unit, housed in a standard CAMAC crate, operates under microcomputer control. Functions are performed under program control, which resides in nonvolatile read-only memory. Communication with CICADA control system is provided via an 11-bit parallel interface

  8. Design of coordinated controller in nuclear power plant based on digital instrument and control technology

    International Nuclear Information System (INIS)

    Cheng Shouyu; Peng Minjun; Liu Xinkai; Zhao Qiang; Deng Xiangxin

    2014-01-01

    Nuclear power plant (NPP) is a multi-input and multi-output, no-linear and time-varying complex system. The conventional PID controller is usually used in NPP control system which is based on analog instrument. The system parameters are easy to overshoot and the response time is longer in the control mode of the conventional PID. In order to improve this condition, a new coordinated control strategy which is based on expert system and the original controllers in the digital instrument and control technology was presented. In order to verify and validate it, the proposed coordinated control technology was tested by the full-scope real-time simulation system. The results prove that using digital instrument and control technology to achieve coordinated controller is feasible, the coordinated controller can effectively improve the dynamic operating characteristics of the system, and the coordinated controller is superior to the conventional PID controller in control performance. (authors)

  9. Quality control for diagnostic oral microbiology laboratories in European countries

    NARCIS (Netherlands)

    Rautemaa-Richardson, R.; van der Reijden, W.A.; Dahlen, G.; Smith, A.J.

    2011-01-01

    Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB)

  10. ASIC design of a digital fuzzy system on chip for medical diagnostic applications.

    Science.gov (United States)

    Roy Chowdhury, Shubhajit; Roy, Aniruddha; Saha, Hiranmay

    2011-04-01

    The paper presents the ASIC design of a digital fuzzy logic circuit for medical diagnostic applications. The system on chip under consideration uses fuzzifier, memory and defuzzifier for fuzzifying the patient data, storing the membership function values and defuzzifying the membership function values to get the output decision. The proposed circuit uses triangular trapezoidal membership functions for fuzzification patients' data. For minimizing the transistor count, the proposed circuit uses 3T XOR gates and 8T adders for its design. The entire work has been carried out using TSMC 0.35 µm CMOS process. Post layout TSPICE simulation of the whole circuit indicates a delay of 31.27 ns and the average power dissipation of the system on chip is 123.49 mW which indicates a less delay and less power dissipation than the comparable embedded systems reported earlier.

  11. Fast digital feedback control systems for accelerator RF system using FPGA

    International Nuclear Information System (INIS)

    Bagduwal, Pritam Singh; Sharma, Dheeraj; Tiwari, Nitesh; Lad, M.; Hannurkar, P.R.

    2012-01-01

    Feedback control system plays important role for proper injection and acceleration of beam in particle accelerators by providing the required amplitude and phase stability of RF fields in accelerating structures. Advancement in the field of digital technology enables us to develop fast digital feedback control system for RF applications. Digital Low Level RF (LLRF) system offers the inherent advantages of Digital System like flexibility, adaptability, good repeatability and reduced long time drift errors compared to analog system. To implement the feedback control algorithm, I/Q control scheme is used. By properly sampling the down converted IF signal using fast ADC we get accurate feedback signal and also eliminates the need of two separate detectors for amplitude and phase detection. Controller is implemented in Vertex-4 FPGA. Codes for control algorithms which controls the amplitude and phase in all four quadrants with good accuracy are written in the VHDL. I/Q modulator works as common actuator for both amplitude and phase correction. Synchronization between RF, LO and ADC clock is indispensable and has been achieved by deriving the clock and LO signal from RF signal itself. Control system has been successfully tested in lab with phase and amplitude stability better then ±1% and ±1° respectively. High frequency RF signal is down converted to IF using the super heterodyne technique. Super heterodyne principal not only brings the RF signal to the Low IF frequency at which it can be easily processed but also enables us to use the same hardware and software for other RF frequencies with some minor modification. (author)

  12. Rapid and Accurate Behavioral Health Diagnostic Screening: Initial Validation Study of a Web-Based, Self-Report Tool (the SAGE-SR).

    Science.gov (United States)

    Brodey, Benjamin; Purcell, Susan E; Rhea, Karen; Maier, Philip; First, Michael; Zweede, Lisa; Sinisterra, Manuela; Nunn, M Brad; Austin, Marie-Paule; Brodey, Inger S

    2018-03-23

    The Structured Clinical Interview for DSM (SCID) is considered the gold standard assessment for accurate, reliable psychiatric diagnoses; however, because of its length, complexity, and training required, the SCID is rarely used outside of research. This paper aims to describe the development and initial validation of a Web-based, self-report screening instrument (the Screening Assessment for Guiding Evaluation-Self-Report, SAGE-SR) based on the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) and the SCID-5-Clinician Version (CV) intended to make accurate, broad-based behavioral health diagnostic screening more accessible within clinical care. First, study staff drafted approximately 1200 self-report items representing individual granular symptoms in the diagnostic criteria for the 8 primary SCID-CV modules. An expert panel iteratively reviewed, critiqued, and revised items. The resulting items were iteratively administered and revised through 3 rounds of cognitive interviewing with community mental health center participants. In the first 2 rounds, the SCID was also administered to participants to directly compare their Likert self-report and SCID responses. A second expert panel evaluated the final pool of items from cognitive interviewing and criteria in the DSM-5 to construct the SAGE-SR, a computerized adaptive instrument that uses branching logic from a screener section to administer appropriate follow-up questions to refine the differential diagnoses. The SAGE-SR was administered to healthy controls and outpatient mental health clinic clients to assess test duration and test-retest reliability. Cutoff scores for screening into follow-up diagnostic sections and criteria for inclusion of diagnoses in the differential diagnosis were evaluated. The expert panel reduced the initial 1200 test items to 664 items that panel members agreed collectively represented the SCID items from the 8 targeted modules and DSM criteria for the covered

  13. Quality control in digital mammography: the noise components

    Energy Technology Data Exchange (ETDEWEB)

    Leyton, Fernando [Universidade de Tarapaca, Arica (Chile). Centro de Estudios en Ciencias Radiologicas; Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Nogueira, Maria do Socorro, E-mail: mnogue@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Duran, Maria Paz [Clinica Alemana, Santiago (Chile). Dept. de Radiologia; Dantas, Marcelino, E-mail: marcelino@inb.gov.b [Industrias Nucleares do Brasil (INB), Caldas, MG (Brazil). Unidade de Tratamento de Minerios; Ubeda, Carlos, E-mail: cubeda@uta.c [Universidade de Tarapaca, Arica (Chile). Fac. de Ciencias de la Salud

    2011-07-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  14. Quality control in digital mammography: the noise components

    International Nuclear Information System (INIS)

    Leyton, Fernando; Nogueira, Maria do Socorro; Duran, Maria Paz; Dantas, Marcelino; Ubeda, Carlos

    2011-01-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  15. Negative Peer Relationships on Piracy Behavior: A Cross-Sectional Study of the Associations between Cyberbullying Involvement and Digital Piracy

    Directory of Open Access Journals (Sweden)

    Santiago Yubero

    2017-10-01

    Full Text Available The present study examines the relationship between different roles in cyberbullying behaviors (cyberbullies, cybervictims, cyberbullies-victims, and uninvolved and self-reported digital piracy. In a region of central Spain, 643 (49.3% females, 50.7% males students (grades 7–10 completed a number of self-reported measures, including cyberbullying victimization and perpetration, self-reported digital piracy, ethical considerations of digital piracy, time spent on the Internet, and leisure activities related with digital content. The results of a series of hierarchical multiple regression models for the whole sample indicate that cyberbullies and cyberbullies-victims are associated with more reports of digital piracy. Subsequent hierarchical multiple regression analyses, done separately for males and females, indicate that the relationship between cyberbullying and self-reported digital piracy is sustained only for males. The ANCOVA analysis show that, after controlling for gender, self-reported digital piracy and time spent on the Internet, cyberbullies and cyberbullies-victims believe that digital piracy is a more ethically and morally acceptable behavior than victims and uninvolved adolescents believe. The results provide insight into the association between two deviant behaviors.

  16. Demonstrative fractional order - PID controller based DC motor drive on digital platform.

    Science.gov (United States)

    Khubalkar, Swapnil W; Junghare, Anjali S; Aware, Mohan V; Chopade, Amit S; Das, Shantanu

    2017-09-21

    In industrial drives applications, fractional order controllers can exhibit phenomenal impact due to realization through digital implementation. Digital fractional order controllers have created wide scope as it possess the inherent advantages like robustness against the plant parameter variation. This paper provides brief design procedure of fractional order proportional-integral-derivative (FO-PID) controller through the indirect approach of approximation using constant phase technique. The new modified dynamic particle swarm optimization (IdPSO) technique is proposed to find controller parameters. The FO-PID controller is implemented using floating point digital signal processor. The building blocks are designed and assembled with all peripheral components for the 1.5kW industrial DC motor drive. The robust operation for parametric variation is ascertained by testing the controller with two separately excited DC motors with the same rating but different parameters. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  17. [Digital electroencephalography in brain death diagnostics : Technical requirements and results of a survey on the compatibility with medical guidelines of digital EEG systems from providers in Germany].

    Science.gov (United States)

    Walter, U; Noachtar, S; Hinrichs, H

    2018-02-01

    The guidelines of the German Medical Association and the German Society for Clinical Neurophysiology and Functional Imaging (DGKN) require a high procedural and technical standard for electroencephalography (EEG) as an ancillary method for diagnosing the irreversible cessation of brain function (brain death). Nowadays, digital EEG systems are increasingly being applied in hospitals. So far it is unclear to what extent the digital EEG systems currently marketed in Germany meet the guidelines for diagnosing brain death. In the present article, the technical und safety-related requirements for digital EEG systems and the EEG documentation for diagnosing brain death are described in detail. On behalf of the DGKN, the authors sent out a questionnaire to all identified distributors of digital EEG systems in Germany with respect to the following technical demands: repeated recording of the calibration signals during an ongoing EEG recording, repeated recording of all electrode impedances during an ongoing EEG recording, assessability of intrasystem noise and galvanic isolation of measurement earthing from earthing conductor (floating input). For 15 of the identified 20 different digital EEG systems the specifications were provided by the distributors (among them all distributors based in Germany). All of these EEG systems are provided with a galvanic isolation (floating input). The internal noise can be tested with all systems; however, some systems do not allow repeated recording of the calibration signals and/or the electrode impedances during an ongoing EEG recording. The majority but not all of the currently available digital EEG systems offered for clinical use are eligible for use in brain death diagnostics as per German guidelines.

  18. Nuclear reactor and production systems with digital controls

    International Nuclear Information System (INIS)

    Luger, P.P.

    1976-01-01

    Several digital sensing devices are described for use in automated production systems. The first described is for use in the automatic operation of a reactor. This device employs a binant electrometer using a quartz fiber mounted at one end but free to vibrate at the other in an AC field. The fiber oscillates if a charge is placed upon it. An optical slit replaces the ordinary eyepiece reticule scale. With the quartz fiber adjusted so its image is in focus at the optical slit, photoelectric signals are obtained at null charge on the fiber. The quartz fiber is repeatedly charged and allowed to discharge by collecting ions from a source under measurement. Each photoelectric signal causes a digital time reading to be taken. The time readings are used to evaluate the current due to the collected charge. The photoelectric signals, by feedback, also operate the electrometer for continuous or intermittent-continuous operation. Basically, the system is a current digitizer. Application is made to reactor monitoring and control as well as to other types of production systems. Finally, other types of sensing devices are also described and their use in automated controlled processes is shown. 3 claims, 19 figures

  19. Anticipatory modulation of digit placement for grasp control is affected by Parkinson's disease.

    Directory of Open Access Journals (Sweden)

    Jamie R Lukos

    2010-02-01

    Full Text Available Successful object manipulation relies on the ability to form and retrieve sensorimotor memories of digit forces and positions used in previous object lifts. Past studies of patients affected by Parkinson's disease (PD have revealed that the basal ganglia play a crucial role in the acquisition and/or retrieval of sensorimotor memories for grasp control. Whereas it is known that PD impairs anticipatory control of digit forces during grasp, learning deficits associated with the planning of digit placement have yet to be explored. This question is motivated by recent work in healthy subjects revealing that anticipatory control of digit placement plays a crucial role for successful manipulation.We asked ten PD patients off medication and ten age-matched controls to reach, grasp and lift an object whose center of mass (CM was on the left, right or center. The only task requirement was to minimize object roll during lift. The CM remained the same across consecutive trials (blocked condition or was altered from trial to trial (random condition. We hypothesized that impairment of the basal ganglia-thalamo-cortical circuits in PD patients would reduce their ability to anticipate digit placement appropriate to the CM location. Consequently, we predicted that PD patients would exhibit similar digit placement in the blocked vs. random conditions and produce larger peak object rolls than that of control subjects. In the blocked condition, PD patients exhibited significantly weaker modulation of fingertip contact points to CM location and larger object roll than controls (p<0.05 and p<0.01, respectively. Nevertheless, both controls and PD patients minimized object roll more in the blocked than in the random condition (p<0.01.Our findings indicate that, even though PD patients may have a residual ability of anticipatory control of digit contact points and forces, they fail to implement a motor plan with the same degree of effectiveness as controls. We conclude

  20. Fault-tolerant design of adaptive digital control systems for power plant components

    International Nuclear Information System (INIS)

    Parlos, A.G.; Menon, S.K.

    1992-01-01

    An adaptive controller has been designed for the water level of a Westinghouse type U-tube steam generator, and its operation has been demonstrated in the entire power range via computer simulations. The proposed design exhibits improved performance, at low operating powers, a,s compared to existing controller types. The continuous-time controller design is performed systematically via the Linear Quadratic Gaussian/Loop Transfer Recovery method, followed by gain adaptation allowing controller operation in the entire power range. Digital implementation of the controller is accomplished by a digital redesign which results in matching the digital and continuous-time system and controller states. It is only at this stage of the control system design process that issues such as microprocessor induced quantization effects are taken into account. The use of computer-aided-design software greatly expedites the design cycle, allowing the designer to maximize the controller stability robustness to uncertainties via numerous iterations. This inherent controller robustness can be exploited to tolerate incipient plant faults, such as deteriorating U-tube heat transfer properties, without significant loss of controller performance

  1. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Baorong, Yue

    2008-01-01

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  2. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: Prospective, multicentre cohort study

    NARCIS (Netherlands)

    C.J.J. Van Asch (Charlotte J.J.); B.K. Velthuis (Birgitta K.); G.J.E. Rinkel (Gabriël J.E.); A. Algra (Ale); G.A.P. de Kort (G. A P); T.D. Witkamp (Theo); J.C.M. De Ridder (Johanna C.M.); K.M. Van Nieuwenhuizen (Koen M.); F.-E. De Leeuw (Frank-Erik); W.J. Schonewille (Wouter); P.L.M. de Kort (Paul); D.W.J. Dippel (Diederik); T.W.M. Raaymakers (Theodora W.M.); J. Hofmeijer; M.J.H. Wermer (Marieke); H. Kerkhoff (Henk); K. Jellema (Korné); I.M. Bronner (Irene M.); M.J.M. Remmers (Michel ); H.P. Bienfait (Henri); R.J.G.M. Witjes (Ron J.G.M.); J.P. Greving (Jacoba); C.J.M. Klijn (Catharina J.M.); H.F. de Leeuw (Frank); H.B. Boogaarts; E.J. van Dijk (Ewoud); W.J. Schonewille; W.M.J. Pellikaan; C. Puppels-De Waard; P.L.M. De Kort; J.P. Peluso; J. van Tuijl (Jordie); J. Hofmeijer; F.B.M. Joosten (Frank); D.W.J. Dippel (Diederik); L. Khajeh (Ladbon); T.W.M. Raaijmakers; M.J. Wermer; M.A.A. van Walderveen (Marianne); H. Kerkhoff; E. Zock; K. Jellema (Korné); G.J. Lycklama à Nijeholt (Geert); I.M. Bronner; M.J.M. Remmers; R.J.G.M. Witjes; H.P. Bienfait; K.E. Droogh-Greve; R. Donders (Rogier); V.I.H. Kwa; T.H.C.M.L. Schreuder (Tobien H. C. M. L.); C.L. Franke (Cees); J.S. Straver; C. Jansen; S.L.M. Bakker (Stef); C.C. Pleiter (C.); M.C. Visser; C.J.J. Van Asch; B.K. Velthuis (Birgitta); G.J.E. Rinkel (Gabriel); K.M. Van Nieuwenhuizen; C.J.M. Klijn (Catharina J.M.)

    2015-01-01

    textabstractStudy question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This

  3. Dysphagia following stroke: evaluation with digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Sung Nam; Kang, Heoung Keun; Joo, Jung Hyun; Kim, Chang Il; Park, Soo Min; Jeong, Yong Yeon; Seo, Jeong Jin; Chung, Tae Woong [Chonnam Univ., Kwanju (Korea, Republic of). Medical School

    1997-12-01

    The purpose of this study is to evaluate the usefulness of digital radiography in the assessment of dysphagia following stroke. Eighteen stroke patients (8 men, 10 women) referred for dysphagia and ten controls without known pharyngeal swallowing difficulty underwent digital radiography using a 1:1 mixture of barium and water. We evaluated oropharyngeal transit time and the location and severity of dysphagia; transit time was defined as the time from the first movement of the bolus to the return of the epiglottis to its original position. We sought to observe specific patterns of oropharyngeal dysfunction; dysphagia was classified as mild, moderate, or severe. The dynamic image of the pharynx, as seen on a digital radiograph, may be diagnostically useful for defining the location and severity of dysphagia; in order to make feeding recommendations, this information is essential. (author). 17 refs., 5 figs.

  4. Design and Testing of Digital Microfluidic Biochips

    CERN Document Server

    Zhao, Yang

    2013-01-01

    This book provides a comprehensive methodology for automated design, test and diagnosis, and use of robust, low-cost, and manufacturable digital microfluidic systems. It focuses on the development of a comprehensive CAD optimization framework for digital microfluidic biochips that unifies different design problems. With the increase in system complexity and integration levels, biochip designers can utilize the design methods described in this book to evaluate different design alternatives, and carry out design-space exploration to obtain the best design point. Describes practical design automation tools that address different design problems (e.g., synthesis, droplet routing, control-pin mapping, testing and diagnosis, and error recovery) in a unified manner; Applies test pattern generation and error-recovery techniques for digital microfluidics-based biochips; Uses real bioassays as evaluation examples, e.g., multiplexed in vitro human physiological fluids diagnostics, PCR, protein crystallization.  

  5. Dysphagia following stroke: evaluation with digital radiography

    International Nuclear Information System (INIS)

    Chu, Sung Nam; Kang, Heoung Keun; Joo, Jung Hyun; Kim, Chang Il; Park, Soo Min; Jeong, Yong Yeon; Seo, Jeong Jin; Chung, Tae Woong

    1997-01-01

    The purpose of this study is to evaluate the usefulness of digital radiography in the assessment of dysphagia following stroke. Eighteen stroke patients (8 men, 10 women) referred for dysphagia and ten controls without known pharyngeal swallowing difficulty underwent digital radiography using a 1:1 mixture of barium and water. We evaluated oropharyngeal transit time and the location and severity of dysphagia; transit time was defined as the time from the first movement of the bolus to the return of the epiglottis to its original position. We sought to observe specific patterns of oropharyngeal dysfunction; dysphagia was classified as mild, moderate, or severe. The dynamic image of the pharynx, as seen on a digital radiograph, may be diagnostically useful for defining the location and severity of dysphagia; in order to make feeding recommendations, this information is essential. (author). 17 refs., 5 figs

  6. Integrated control and diagnostic system architectures for future installations

    International Nuclear Information System (INIS)

    Wood, R.; March-Leuba, J.

    2000-01-01

    Nuclear reactors of the 21st century will employ increasing levels of automation and fault tolerance to increase availability, reduce accident risk, and lower operating costs. Key developments in control algorithms, fault diagnostics, fault tolerance, and distributed communications are needed to implement the fully automated plant. It will be equally challenging to integrate developments in separate information and control fields into a cohesive system, which collectively achieves the overall goals of improved safety, reliability, maintainability, and cost-effectiveness. Under the Nuclear Energy Research Initiative (NERI), the US Department of Energy is sponsoring a project to address some of the technical issues involved in meeting the long-range goal of 21st century reactor control systems. This project involves researchers from Oak Ridge National Laboratory, the University of Tennessee, and North Carolina State University. The research tasks under this project focus on some of the first-level breakthroughs in control design, diagnostic techniques, and information system design that will provide a path to enable the design process to be automated in the future. This paper describes the conceptual development of an integrated nuclear plant control and information system architecture, which incorporates automated control system development that can be traced to a set of technical requirements. The expectation is that an integrated plant architecture with optimal control and efficient use of diagnostic information can reduce the potential for operational errors and minimize challenges to the plant safety systems

  7. Digital Relationships

    DEFF Research Database (Denmark)

    Ledborg Hansen, Richard

    -­rich information and highly interesting communication are sky-­high and rising. With a continuous increase in digitized communication follows a decrease in face-­to-­face encounters and our ability to engage in inter-­personal relationships are suffering for it (Davis, 2013). The behavior described in this paper......-­‐Jones, 2011) for increases in effectiveness and efficiency we indiscriminately embrace digital communication and digitized information dissemination with enthusiasm – at the risk of ignoring the potentially dark side of technology. However, technology also holds a promise for better understanding precisely...... for the same reasons – that the growing amount of digitized communication “out there” represents data waiting to be sifted, analyzed and decoded. In this paper “Facebook behavior” refers to a particular behavior characterized by presenting your self and representations of selected self in the hope of getting...

  8. General digitalized system on nuclear power plants

    International Nuclear Information System (INIS)

    Akagi, Katsumi; Kadohara, Hozumi; Taniguchi, Manabu

    2000-01-01

    Hitherto, instrumentation control system in a PWR nuclear power plant has stepwisely adopted digital technology such as application of digital instrumentation control device to ordinary use (primary/secondary system control device, and so on), application of CRT display system to monitoring function, and so forth, to realize load reduction of an operator due to expansion of operation automation range, upgrading of reliability and maintenance due to self-diagnosis function, reduction of mass in cables due to multiple transfer, and upgrading of visual recognition due to information integration. In next term PWR plant instrumentation control system, under consideration of application practice of conventional digital technology, application of general digitalisation system to adopt digitalisation of overall instrumentation control system containing safety protection system, and central instrumentation system (new type of instrumentation system) and to intend to further upgrade economics, maintenance, operability/monitoring under security of reliability/safety is planned. And, together with embodiment of construction program of the next-term plant, verification at the general digitalisation proto-system aiming at establishment of basic technology on the system is carried out. Then, here was described on abstract of the general digitalisation system and characteristics of a digital type safety protection apparatus to be adopted in the next-term plant. (G.K.)

  9. The modular design method for digital control systems in Japanese BWRs

    International Nuclear Information System (INIS)

    Kondoh, Y.; Motomura, A.

    1998-01-01

    Digital technology is being applied to control systems in nuclear power plants. Especially in Japanese BWRs, control systems are being digitized both in constructing plant and in retrofit of operating plants. Digital technology has many advantages compared with analog technology. However, its high performance and flexibility may result in too complicated software structure, which will cause long design time and long testing time and increase cost. In introduction of digital technology, it is most important to restrict unnecessary flexibility of software. The function of control systems can be divided in standard part and variable part. Standard function may be common to every plant while variable function should be designed for each plant. Even in current design, standard design is preserved to be reused in next application. However, this design approach is not always effective because standard function may be changed by customer and nothing is considered for variable part even if it is large. To keep reliability and reduce cost by software reuse, Toshiba adopts modular design of control software, where standard part is designed as a set of standard functional modules and variable function is designed as a complex of standard functional modules and plant unique modules. Toshiba firstly applied modular design method to fuel handling machine control system. In this application the design work has been reduced to 30 percent by reusing of functional module which was first developed in former applications. This remarkable reduction of design work has enhanced reliability with less cost. In addition, software, has been produced and tested according to the functional module. These qualified software modules will be applied to next system and will realize highest reliability and least cost. Toshiba is now planning the application of this modular design method for every digital control system. (author)

  10. Stability of digital feedback control systems

    Directory of Open Access Journals (Sweden)

    Larkin Eugene

    2018-01-01

    Lag time characteristics are used for investigation of stability of linear systems. Digital PID controller is divided onto linear part, which is realized with a soft and pure lag unit, which is realized with both hardware and software. With use notions amplitude and phase margins, condition for stability of system functioning are obtained. Theoretical results are confirm with computer experiment carried out on the third-order system.

  11. Six factors of adult dyslexia assesed by cognitive tests and self-report questions: Very high predictive validity

    NARCIS (Netherlands)

    Tamboer, P.; Vorst, H.C.M.; de Jong, P.F.

    2017-01-01

    The Multiple Diagnostic Digital Dyslexia Test for Adults (MDDDT-A) consists of 12 newly developed tests and self-report questions in the Dutch language. Predictive validity and construct validity were investigated and compared with validity of a standard test battery of dyslexia (STB) in a sample of

  12. Quality Control in Diagnostic Radiology: Experiences and Achievements

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Salleh; Muhammad Jamal Md Isa

    2015-01-01

    Malaysian Nuclear Agency through its Medical Physics Group has been providing Quality Control (QC) services for medical X-ray apparatus used in diagnostic radiology to private clinics and hospitals since the year 1997. The Medical Physics Groups services is endorsed by the Malaysian Ministry Of Health (MOH) and is in accordance with the Malaysian Standard MS 838 and the Atomic Energy Licensing Act, 1984. Until today, the scopes of testing services also include all types of medical x-ray apparatus. The quality control (QC) in diagnostic radiology is considered as part of quality assurance program which provide accurate diagnostic information at the lowest cost and the least exposure of the patients to radiation. Many experience and obstacles were faced by Medical Physics Group. This paper will discuss the experiences and achievements of providing QC service from early stage until now so that it can be shared by the citizens of the Malaysian Nuclear Agency. The results of quality assurance inspection of all types of X-ray apparatus for medical conducted by Agency Nuclear Malaysia will be presented in brief. (author)

  13. Development of Digital Control for High Power Permanent-Magnet Synchronous Motor Drives

    Directory of Open Access Journals (Sweden)

    Ming-Hung Chen

    2014-01-01

    Full Text Available This paper is concerned with the development of digital control system for high power permanent-magnet synchronous motor (PMSM to yield good speed regulation, low current harmonic, and stable output speed. The design of controller is conducted by digitizing the mathematical model of PMSM using impulse invariance technique. The predicted current estimator, which is insensitive to motor feedback currents, is proposed to function under stationary frame for harmonic current suppression. In the AC/DC power converter, mathematical model and dc-link voltage limit of the three-phase switch-mode rectifier are derived. In addition, a current controller under synchronous frame is introduced to reduce the current harmonics and increase the power factor on the input side. A digital control system for 75 kW PMSM is realized with digital signal processor (R5F5630EDDFP. Experimental results indicate that the total harmonic distortion of current is reduced from 4.1% to 2.8% for 50 kW output power by the proposed predicted current estimator technique.

  14. Centralized digital computer control of a research nuclear reactor

    International Nuclear Information System (INIS)

    Crawford, K.C.

    1987-01-01

    A hardware and software design for the centralized control of a research nuclear reactor by a digital computer are presented, as well as an investigation of automatic-feedback control. Current reactor-control philosophies including redundancy, inherent safety in failure, and conservative-yet-operational scram initiation were used as the bases of the design. The control philosophies were applied to the power-monitoring system, the fuel-temperature monitoring system, the area-radiation monitoring system, and the overall system interaction. Unlike the single-function analog computers currently used to control research and commercial reactors, this system will be driven by a multifunction digital computer. Specifically, the system will perform control-rod movements to conform with operator requests, automatically log the required physical parameters during reactor operation, perform the required system tests, and monitor facility safety and security. Reactor power control is based on signals received from ion chambers located near the reactor core. Absorber-rod movements are made to control the rate of power increase or decrease during power changes and to control the power level during steady-state operation. Additionally, the system incorporates a rudimentary level of artificial intelligence

  15. Hypo-egoic self-regulation: exercising self-control by diminishing the influence of the self.

    Science.gov (United States)

    Leary, Mark R; Adams, Claire E; Tate, Eleanor B

    2006-12-01

    Theory and research dealing with self-regulation have focused primarily on instances of self-regulation that involve high levels of self-reflection and effortful self-control. However, intentionally trying to control one's behavior sometimes reduces the likelihood of achieving one's goals. This article examines the process of hypo-egoic self-regulation in which people relinquish deliberate, conscious control over their own behavior so that they will respond more naturally, spontaneously, or automatically. An examination of spontaneously occurring hypo-egoic states (such as flow, deindividuation, and transcendence) suggests that hypo-egoic states are characterized by lowered self-awareness and/or an increase in concrete and present-focused self-thoughts. In light of this, people may intentionally foster hypo-egoism via two pathways-(a) taking steps to reduce the proportion of time that they are self-aware (such as repeating a behavior until it is automatic or practicing meditation) or (b) increasing the concreteness of their self-thoughts (such as inducing a concrete mindset or practicing mindfulness). In this way, people may deliberately choose to regulate hypo-egoically when effortful control might be detrimental to their performance.

  16. Genes, Parenting, Self-Control, and Criminal Behavior.

    Science.gov (United States)

    Watts, Stephen J; McNulty, Thomas L

    2016-03-01

    Self-control has been found to predict a wide variety of criminal behaviors. In addition, studies have consistently shown that parenting is an important influence on both self-control and offending. However, few studies have examined the role that biological factors may play in moderating the relationship between parenting, self-control, and offending. Using a sample of adolescent males drawn from the National Longitudinal Study of Adolescent Health (N = 3,610), we explore whether variants of the monoamine oxidase A gene (MAOA) and the dopamine transporter (DAT1) gene interact with parenting to affect self-control and offending. Results reveal that parenting interacts with these genes to influence self-control and offending, and that the parenting-by-gene interaction effect on offending is mediated by self-control. The effects of parenting on self-control and offending are most pronounced for those who carry plasticity alleles for both MAOA and DAT1. Thus, MAOA and DAT1 may be implicated in offending because they increase the negative effects of parenting on self-control. Implications for theory are discussed. © The Author(s) 2014.

  17. Self-organization in the limb: a Turing mechanism for digit development.

    Science.gov (United States)

    Cooper, Kimberly L

    2015-06-01

    The statistician George E. P. Box stated, 'Essentially all models are wrong, but some are useful.' (Box GEP, Draper NR: Empirical Model-Building and Response Surfaces. Wiley; 1987). Modeling biological processes is challenging for many of the reasons classically trained developmental biologists often resist the idea that black and white equations can explain the grayscale subtleties of living things. Although a simplified mathematical model of development will undoubtedly fall short of precision, a good model is exceedingly useful if it raises at least as many testable questions as it answers. Self-organizing Turing models that simulate the pattern of digits in the hand replicate events that have not yet been explained by classical approaches. The union of theory and experimentation has recently identified and validated the minimal components of a Turing network for digit pattern and triggered a cascade of questions that will undoubtedly be well-served by the continued merging of disciplines. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Developing a digital photography-based method for dietary analysis in self-serve dining settings.

    Science.gov (United States)

    Christoph, Mary J; Loman, Brett R; Ellison, Brenna

    2017-07-01

    Current population-based methods for assessing dietary intake, including food frequency questionnaires, food diaries, and 24-h dietary recall, are limited in their ability to objectively measure food intake. Digital photography has been identified as a promising addition to these techniques but has rarely been assessed in self-serve settings. We utilized digital photography to examine university students' food choices and consumption in a self-serve dining hall setting. Research assistants took pre- and post-photos of students' plates during lunch and dinner to assess selection (presence), servings, and consumption of MyPlate food groups. Four coders rated the same set of approximately 180 meals for inter-rater reliability analyses; approximately 50 additional meals were coded twice by each coder to assess intra-rater agreement. Inter-rater agreement on the selection, servings, and consumption of food groups was high at 93.5%; intra-rater agreement was similarly high with an average of 95.6% agreement. Coders achieved the highest rates of agreement in assessing if a food group was present on the plate (95-99% inter-rater agreement, depending on food group) and estimating the servings of food selected (81-98% inter-rater agreement). Estimating consumption, particularly for items such as beans and cheese that were often in mixed dishes, was more challenging (77-94% inter-rater agreement). Results suggest that the digital photography method presented is feasible for large studies in real-world environments and can provide an objective measure of food selection, servings, and consumption with a high degree of agreement between coders; however, to make accurate claims about the state of dietary intake in all-you-can-eat, self-serve settings, researchers will need to account for the possibility of diners taking multiple trips through the serving line. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Efficiency and hardware comparison of analog control-based and digital control-based 70 W two-stage power factor corrector and DC-DC converters

    DEFF Research Database (Denmark)

    Török, Lajos; Munk-Nielsen, Stig

    2011-01-01

    A comparison of an analog and a digital controller driven 70 W two-stage power factor corrector converter is presented. Both controllers are operated in average current-mode-control for the PFC and peak current control for the DC-DC converter. Digital controller design and converter modeling...... is described. Results show that digital control can compete with the analog one in efficiency, PFC and THD....

  20. Feedback control and beam diagnostic algorithms for a multiprocessor DSP system

    International Nuclear Information System (INIS)

    Teytelman, D.; Claus, R.; Fox, J.; Hindi, H.; Linscott, I.; Prabhakar, S.

    1996-09-01

    The multibunch longitudinal feedback system developed for use by PEP-II, ALS and DAΦNE uses a parallel array of digital signal processors to calculate the feedback signals from measurements of beam motion. The system is designed with general-purpose programmable elements which allow many feedback operating modes as well as system diagnostics, calibrations and accelerator measurements. The overall signal processing architecture of the system is illustrated. The real-time DSP algorithms and off-line postprocessing tools are presented. The problems in managing 320 K samples of data collected in one beam transient measurement are discussed and the solutions are presented. Example software structures are presented showing the beam feedback process, techniques for modal analysis of beam motion(used to quantify growth and damping rates of instabilities) and diagnostic functions (such as timing adjustment of beam pick-up and kicker components). These operating techniques are illustrated with example results obtained from the system installed at the Advanced Light Source at LBL

  1. Data Driven Synthesis of Three Term Digital Controllers

    Science.gov (United States)

    Keel, Lee H.; Mitra, Sandipan; Bhattacharyya, Shankar P.

    This paper presents a method for digital PID and first order controller synthesis based on frequency domain data alone. The techniques given here first determine all stabilizing controllers from measurement data. In both PID and first order controller cases, the only information required are frequency domain data (Nyquist-Bode data) and the number of open-loop RHP poles. Specifically no identification of the plant model is required. Examples are given for illustration.

  2. How Finnish and Swedish Learners’ Academic Self-Control Relates to Time Spent Online in Class, Perceptions of Educator Qualities, and School Appreciation: A Cross-Sectional Comparison

    Directory of Open Access Journals (Sweden)

    Thomas Arnesen

    2017-08-01

    Full Text Available In school settings, self-control is central to the ability of learners to complete their academic work successfully. Learners’ self-control is directly influenced by the ways in which educators execute their work, including their instructional explanations, their classroom management, and the expectations that they express to their learners. Our research on this phenomenon investigated Finnish and Swedish learners in upper secondary schools. Not only is the use of digital technology very different in these two countries; the autonomy and status of educators are as well. This article compares the empirical significance of antecedents of learners’ academic self-control in the two national settings by surveying 2191 learners in Swedish and Finnish schools. Our analysis applies structural equation modeling to two cross-sectional datasets, and the results reveal that the associations between educators’ instructional explanations, classroom management, and their high expectations on the one hand and learners’ academic self-control on the other are stronger overall among Finnish students than among Swedish students. Furthermore, the association between digital technology use and learners’ perceptions of conflict between school norms and Internet opportunities are much stronger in the Swedish sample than the Finnish sample. Lastly, we discuss the meaning of these results and their possible implications for research and practice.

  3. Basic quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Wikstrom, Erik

    2016-01-01

    Along the route toward regular performance of Quality Control in the Diagnostic Imaging sector there are a number of balances to negotiate: Patient/Staff safety considerations vs Regulatory compliance vs Performance of modern equipment vs Clinic's Productivity. At first glance these ambitions may seem in conflict. The tests performed to meet regulatory requirements may or may not bear any semblance to real clinical measurement scenarios. And the process of collecting the data from the quality assurance tests may induce a system down- time that adversely affects the clinic's overall productivity. Furthermore, the time it takes to complete the analysis of the test data and provide the report required to take the facility back into operation is time wasted for patients waiting for a diagnostic imaging exam

  4. Digital mammography: current state and future aspects

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, U.; Baum, F. [Womens Health Care Center Goettingen, Diagnostisches Brustzentrum Goettingen, Goettingen (Germany); Hermann, K.P. [Georg-August-Universitaet Goettingen, Abteilung Diagnostische Radiologie, Goettingen (Germany)

    2006-01-01

    The introduction of digital technique in mammography has been the last step in completing the process of digitalization in diagnostic imaging. Meanwhile, some different digital techniques as well as a couple of different digital mammography systems were developed and have already been available for some years. In this review article, the relevant data of key studies are reported, the current status is defined, and perspectives of digital mammography are described. (orig.)

  5. Sixth NASA Glenn Research Center Propulsion Control and Diagnostics (PCD) Workshop

    Science.gov (United States)

    Litt, Jonathan S. (Compiler)

    2018-01-01

    The Intelligent Control and Autonomy Branch at NASA Glenn Research Center hosted the Sixth Propulsion Control and Diagnostics Workshop on August 22-24, 2017. The objectives of this workshop were to disseminate information about research being performed in support of NASA Aeronautics programs; get feedback from peers on the research; and identify opportunities for collaboration. There were presentations and posters by NASA researchers, Department of Defense representatives, and engine manufacturers on aspects of turbine engine modeling, control, and diagnostics.

  6. Real-time signal communication between diagnostic and control in ASDEX Upgrade

    International Nuclear Information System (INIS)

    Treutterer, Wolfgang; Neu, Gregor; Raupp, Gerhard; Zehetbauer, Thomas; Zasche, Dieter; Lueddecke, Klaus; Cole, Richard

    2010-01-01

    The ASDEX Upgrade tokamak experiment is equipped with a versatile discharge monitoring and control system. It allows to develop and use advanced control algorithms to investigate plasma physics under well-defined conditions with the objective of optimising plasma performance. The achievable quality depends on the accuracy with which the plasma state can be reconstructed from measurements under real-time conditions. Today's advanced algorithms need physics quantities - scalar entities as well as profiles. These are obtained processing huge numbers of raw measurements with complex diagnostic algorithms. Adequate network communication for the resulting signals is crucial to satisfy real-time requirements, especially when several diagnostic systems cooperate in a feedback control loop. Support for the technology of choice, however, is not easily available for all of the diverse, highly specialised diagnostic systems. We give an overview about the methods that have been explored at ASDEX Upgrade for real-time signal transfer. In particular, we investigated reflective shared memory and Ethernet technologies. Our solution strives to combine their strengths. For fast communication on dedicated computing nodes, reflective shared memory is used. For the majority of diagnostic systems producing large data blocks at moderate rates, Ethernet connections with UDP protocol are employed. Following ASDEX Upgrade's framework concept, a software layer hides the networks used from both diagnostic and control applications.

  7. Real-time signal communication between diagnostic and control in ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Treutterer, Wolfgang, E-mail: Wolfgang.Treutterer@ipp.mpg.d [Max-Planck Institut fuer Plasmaphysik, Garching, EURATOM Association (Germany); Neu, Gregor; Raupp, Gerhard; Zehetbauer, Thomas; Zasche, Dieter [Max-Planck Institut fuer Plasmaphysik, Garching, EURATOM Association (Germany); Lueddecke, Klaus; Cole, Richard [Unlimited Computer Systems, Iffeldorf (Germany)

    2010-07-15

    The ASDEX Upgrade tokamak experiment is equipped with a versatile discharge monitoring and control system. It allows to develop and use advanced control algorithms to investigate plasma physics under well-defined conditions with the objective of optimising plasma performance. The achievable quality depends on the accuracy with which the plasma state can be reconstructed from measurements under real-time conditions. Today's advanced algorithms need physics quantities - scalar entities as well as profiles. These are obtained processing huge numbers of raw measurements with complex diagnostic algorithms. Adequate network communication for the resulting signals is crucial to satisfy real-time requirements, especially when several diagnostic systems cooperate in a feedback control loop. Support for the technology of choice, however, is not easily available for all of the diverse, highly specialised diagnostic systems. We give an overview about the methods that have been explored at ASDEX Upgrade for real-time signal transfer. In particular, we investigated reflective shared memory and Ethernet technologies. Our solution strives to combine their strengths. For fast communication on dedicated computing nodes, reflective shared memory is used. For the majority of diagnostic systems producing large data blocks at moderate rates, Ethernet connections with UDP protocol are employed. Following ASDEX Upgrade's framework concept, a software layer hides the networks used from both diagnostic and control applications.

  8. Taking stock of self-control: A meta-analysis of how self-control affects a wide range of behaviors

    NARCIS (Netherlands)

    de Ridder, D.; Lensvelt-Mulders, G.; Finkenauer, C.; Stok, M.; Baumeister, R. F.

    2012-01-01

    Given assertions of the theoretical, empirical, and practical importance of self-control, this meta-analytic study sought to review evidence concerning the relationship between dispositional self-control and behavior. The authors provide a brief overview over prominent theories of self-control,

  9. Evaluation and quality control of digital subtraction angiography systems

    International Nuclear Information System (INIS)

    Louisot, P.

    1986-04-01

    After reviewing the development of systems used in angiography, we rewind the medical interest and describe the steps of an angiographic examination. The following chapter is dedicated to the techniques used for the digitalization of video images. The components of the system involved in the image acquisition are thoroughly investigated in chapter 4. Then, we analyse the capabilities of the machines available in France in 1985. Chapter 6 is devoted to the criteria of quality in digital imaging. In order to assign qualitative values to the above criteria, we design a control procedure which is described in chapter 7. The procedure thus allows the estimate of the physical performances of angiographic digital subtraction systems [fr

  10. Application of comparative digital holography for distant shape control

    Science.gov (United States)

    Baumbach, Torsten; Osten, Wolfgang; von Kopylow, Christoph; Juptner, Werner P. O.

    2004-09-01

    The comparison of two objects is of great importance in the industrial production process. Especially comparing the shape is of particular interest for maintaining calibration tools or controlling the tolerance in the deviation between a sample and a master. Outsourcing and globalization of production places can result in large distances between co-operating partners and might cause problems for maintaining quality standards. Consequently new challenges arise for optical measurement techniques especially in the field of industrial shape control. In this paper we describe the progress of implementing a novel technique for comparing directly two objects with different microstructure. The technique is based on the combination of comparative holography and digital holography. Comparing the objects can be done in two ways. One is the digital comparison in the computer and the other way is by using the analogue reconstruction of a master hologram with a spatial light modulator (SLM) as coherent mask for illuminating the test object. Since this mask is stored digitally it can be transmitted via telecommunication networks and this enables the access to the full optical information of the master object at any place wanted. Beside the basic principle of comparative digital holography (CDH), we will show in this paper the set-up for doing the analogue comparison of two objects with increased sensitivity in comparison to former measurements and the calibration of the SLM that is used for the experiments. We will give examples for the digital and the analogue comparison of objects including a verification of our results by another optical measurement technique.

  11. Bus-oriented digital control techniques in nuclear power plants

    International Nuclear Information System (INIS)

    Salm, M.

    1987-01-01

    The author states the conservative principles which govern the authorization procedures for nuclear reactor control systems. Using the example of a feedwater supply regulator, employing a digital, bus-oriented control system, he describes how the stigma attached to the word nuclear can be alleviated. (G.T.H.)

  12. Self-adaptive isogeometric global digital image correlation and digital height correlation

    NARCIS (Netherlands)

    Hoefnagels, J. P M; Kleinendorst, S. M.; Ruybalid, A. P.; Verhoosel, C. V.; Geers, M. G D; Yoshida, S.; Lamberti, L.; Sciammarella, C.

    2017-01-01

    This work explores the full potential of isogeometric shape functions for global digital image correlation. To this end, a novel DIC and DHC (digital height correlation) methodology have been developed based on adaptive refinement of isogeometric shape functions. Non-Uniform Rational B-Spline

  13. Tangible Cooperative Gestures: Improving Control and Initiative in Digital Photo Sharing

    Directory of Open Access Journals (Sweden)

    Elise van den Hoven

    2015-09-01

    Full Text Available This paper focuses on co-present digital photo sharing on a notebook and investigates how this could be supported. While analyzing the current digital photo sharing situation we noticed that there was a high threshold for visitors to take control of the personal computer of the photo owner, resulting in inequity of participation. It was assumed that visitors would have the opportunity to interact with the notebook more freely if this threshold was lowered by distributing the user interface and creating a more public, instead of personal, interaction space. This, in turn, could make them feel more involved and in control during a session, creating a more enjoyable experience. To test these assumptions a design prototype was created that stimulates participants to use tangible artifacts for cooperative gestures, a promising direction for the future of HCI. The situation with the cooperative gestures was compared with the regular digital photo sharing situation, which makes use of a keyboard. In dyads, visitors felt more involved and in control in the design prototype cooperative gestures condition (especially during storytelling, resulting in a more enjoyable digital photo sharing experience.

  14. 60 GHz 5-bit digital controlled phase shifter in a digital 40 nm CMOS technology without ultra-thick metals

    NARCIS (Netherlands)

    Gao, H.; Ying, K.; Matters-Kammerer, M.K.; Harpe, P.; Wang, B.; Liu, B.; Serdijn, W.A.; Baltus, P.G.M.

    2016-01-01

    A 5-bit digital controlled switch-type passive phase shifter realised in a 40 nm digital CMOS technology without ultra-thick metals for the 60 GHz Industrial, Scientific and Medical (ISM) band is presented. A patterned shielding with electromagnetic bandgap structure and a stacked metals method to

  15. Digital image intensifier radiography: first experiences with the DSI (Digital Spot Imaging)

    International Nuclear Information System (INIS)

    Rueckforth, J.; Wein, B.; Stargardt, A.; Guenther, R.W.

    1995-01-01

    We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior assessment compared with the film/screen technique. (orig./MG) [de

  16. Diagnostic radiology: I

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter describes the historic development of diagnostic equipment for radiology. The problems associated with fluoroscope design are detailed and the current uses of updated technology, particularly digitization, are considered. Numerous historical photographs are included. 13 refs

  17. Evaluation of underexposed conventional radiographs after digitization

    International Nuclear Information System (INIS)

    Wenz, W.

    1993-01-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.) [de

  18. Experimental direct digital control of the power plant A1 reactor based on a modern control theory approach

    International Nuclear Information System (INIS)

    Karpeta, C.

    1979-01-01

    The objective of the project was to accumulate technical experience with application of modern control theory in nuclear power by carrying out a case study of an experimental direct digital control at the A1 reactor about its nominal steady state. The research has proved that slightly modified method of solution of the linear stochastic regulator problem can be successfully applied in design of digital control system of nuclear power reactors

  19. Digit Ratio (2D:4D) Predicts Self-Reported Measures of General Competitiveness, but Not Behavior in Economic Experiments.

    Science.gov (United States)

    Bönte, Werner; Procher, Vivien D; Urbig, Diemo; Voracek, Martin

    2017-01-01

    The ratio of index finger length to ring finger length (2D:4D) is considered to be a putative biomarker of prenatal androgen exposure (PAE), with previous research suggesting that 2D:4D is associated with human behaviors, especially sex-typical behaviors. This study empirically examines the relationship between 2D:4D and individual competitiveness, a behavioral trait that is found to be sexually dimorphic. We employ two related, but distinct, measures of competitiveness, namely behavioral measures obtained from economic experiments and psychometric self-reported measures. Our analyses are based on two independent data sets obtained from surveys and economic experiments with 461 visitors of a shopping mall (Study I) and 617 university students (Study II). The correlation between behavior in the economic experiment and digit ratios of both hands is not statistically significant in either study. In contrast, we find a negative and statistically significant relationship between psychometric self-reported measures of competitiveness and right hand digit ratios (R2D:4D) in both studies. This relationship is especially strong for younger people. Hence, this study provides some robust empirical evidence for a negative association between R2D:4D and self-reported competitiveness. We discuss potential reasons why digit ratio may relate differently to behaviors in specific economics experiments and to self-reported general competitiveness.

  20. Digit Ratio (2D:4D Predicts Self-Reported Measures of General Competitiveness, but Not Behavior in Economic Experiments

    Directory of Open Access Journals (Sweden)

    Werner Bönte

    2017-12-01

    Full Text Available The ratio of index finger length to ring finger length (2D:4D is considered to be a putative biomarker of prenatal androgen exposure (PAE, with previous research suggesting that 2D:4D is associated with human behaviors, especially sex-typical behaviors. This study empirically examines the relationship between 2D:4D and individual competitiveness, a behavioral trait that is found to be sexually dimorphic. We employ two related, but distinct, measures of competitiveness, namely behavioral measures obtained from economic experiments and psychometric self-reported measures. Our analyses are based on two independent data sets obtained from surveys and economic experiments with 461 visitors of a shopping mall (Study I and 617 university students (Study II. The correlation between behavior in the economic experiment and digit ratios of both hands is not statistically significant in either study. In contrast, we find a negative and statistically significant relationship between psychometric self-reported measures of competitiveness and right hand digit ratios (R2D:4D in both studies. This relationship is especially strong for younger people. Hence, this study provides some robust empirical evidence for a negative association between R2D:4D and self-reported competitiveness. We discuss potential reasons why digit ratio may relate differently to behaviors in specific economics experiments and to self-reported general competitiveness.

  1. Digital tomosynthesis of the breast; Digitale Tomosynthese der Brust

    Energy Technology Data Exchange (ETDEWEB)

    Barkhausen, Joerg [Luebeck Univ. (Germany). Klinik fuer Radiologie und Nuklearmedizin; Rody, Achim [Luebeck Univ. (Germany). Klinik fuer Gynaekologie und Geburtshilfe; Schaefer, Fritz K.W. (ed.) [Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Bereich Mammadiagnostik und Interventionen

    2015-07-01

    The digital tomosynthesis applies the digital image analysis and 3D technology for improves diagnostic uses. The text book on the digital tomosynthesis of the breast covers the following issues: technique of tomosynthesis, clinical significance of digital breast tomosynthesis, innovations and future developments, case studies.

  2. Diagnostic accuracy of self-report and subjective history in the diagnosis of low back pain with non-specific lower extremity symptoms: A systematic review.

    Science.gov (United States)

    Shultz, Susan; Averell, Kristina; Eickelman, Angela; Sanker, Holly; Donaldson, Megan Burrowbridge

    2015-02-01

    Subjective history questions/self-report items are commonly used to triage the patient with low back pain and related leg symptoms. However the value of the history taking process for decision-making to identify common classifications/diagnosis for patients presenting with low back related leg pain (LBRLP) have not been considered. The purpose of this study was to investigate the diagnostic accuracy of self-report items/history-taking questions used to identify patients with LBRLP. Eligible studies included: 1)subjects with low back pain AND related lower extremity pain, 2)details of subjective examination/self-report items, 3)cohort, prospective/longitudinal studies, and randomized control trials, 4)use of statistical reporting, 5)an acceptable reference standard. Quality was evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2. A synthesis of history items that met the threshold for at least a small shift in the likelihood of the condition with a +LR ≥ 2 or -LR ≤ 0.5 were reported. Conditions commonly reported in the literature: lumbar spinal stenosis, lumbosacral nerve root compression/radiculopathy, disc herniation and neurophysiological low back pain ± leg pain. Eleven studies met the inclusion criteria. This is the first systematic review of diagnostic accuracy studies that examined only the history-taking items for their ability to identify LBRLP conditions. Clustering key items may provide a more precise clinical picture necessary to detect and treat a patient's presentation. History questions formed within the interview and their contributing value for decision-making remain understudied. There is a need for better designs to determine a more accurate diagnostic power to identify conditions with LBRLP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Diagnostic orientation in control of disturbance situations

    International Nuclear Information System (INIS)

    Hukki, K.; Norros, L.

    1993-01-01

    The object of the study is diagnostic judgement in the control of dynamic processes. The starting point was the known difficulty process operators have in utilizing knowledge of process dynamics in disturbance situations that require both diagnostic and prognostic actions. A model of the diagnostic judgement process as a construction of coherent interpretation of the situation is outlined, and comprehensive data from simulated disturbance handling by 6 crews of a PWR type nuclear power plant was analysed. The phase of analysis included evaluation of the adequacy of task performance, utilization of available process information, and evaluation of the interpretation of disturbance situations. The results suggest that a functional orientation towards task performance allows a more coherent and comprehensive interpretation of the situation and more adequate task performance. Coherence of interpretation seems to be reflected in a higher subjective certainty compared with crews with an incoherent interpretation. (author). 15 refs, 2 figs, 2 tabs

  4. Is the Control of Applied Digital Forces During Natural Five-digit Grasping Affected by Carpal Tunnel Syndrome?

    Science.gov (United States)

    Chen, Po-Tsun; Jou, I-Ming; Lin, Chien-Ju; Chieh, Hsiao-Feng; Kuo, Li-Chieh; Su, Fong-Chin

    2015-07-01

    The impaired sensory function of the hand induced by carpal tunnel syndrome (CTS) is known to disturb dexterous manipulations. However, force control during daily grasping configuration among the five digits has not been a prominent focus of study. Because grasping is so important to normal function and use of a hand, it is important to understand how sensory changes in CTS affect the digit force of natural grasp. We therefore examined the altered patterns of digit forces applied during natural five-digit grasping in patients with CTS and compared them with those seen in control subjects without CTS. We hypothesized that the patients with CTS will grasp by applying larger forces with lowered pair correlations and more force variability of the involved digits than the control subjects. Specifically, we asked: (1) Is there a difference between patients with CTS and control subjects in applied force by digits during lift-hold-lower task? (2) Is there a difference in force correlation coefficient of the digit pairs? (3) Are there force variability differences during the holding phase? We evaluated 15 female patients with CTS and 15 control subjects matched for age, gender, and hand dominance. The applied radial forces (Fr) of the five digits were recorded by respective force transducers on a cylinder simulator during the lift-hold-lower task with natural grasping. The movement phases of the task were determined by a video-based motion capture system. The applied forces of the thumb in patients with CTS (7 ± 0.8 N; 95% CI, 7.2-7.4 N) versus control subjects (5 ± 0.8 N; 95% CI, 5.1-5.3 N) and the index finger in patients with CTS (3 ± 0.3 N; 95% CI, 3.2-3.3 N) versus control subjects (2 ± 0.3 N; 95% CI, 2.2-2.3 N) observed throughout most of the task were larger in the CTS group (p ranges 0.035-0.050 for thumb and 0.016-0.050 for index finger). In addition, the applied force of the middle finger in patients with CTS (1 ± 0.1 N; 95% CI, 1.3-1.4

  5. A Self-diagnostic Method for the Electrode Adhesion of an Electromagnetic Flow-meter

    Directory of Open Access Journals (Sweden)

    Wen-Hua Cui

    2014-07-01

    Full Text Available Electrodes of electromagnetic flow-meter are subject to contamination in sewage measurement. In this paper, the relationship between the internal resistance of the flow-induced voltage and the electrode contamination is analyzed on the basis of numerical analysis. A new self- diagnostic method for electrode adhesion with additional excitation based on photovoltaic cell is proposed, in which magnetic excitation for flow-rate measurement and electric excitation for electrode self-diagnosis is divided in both time domain and frequency domain. A dual-excited electromagnetic flow-meter with electrode self-diagnosis was designed and validated. Simulation experiments based on the change of the internal resistance of the flow-induced voltage were carried out. And the experimental results fully show that this new method is feasible and promising.

  6. The behavior-analytic approach to emotional self-control

    Directory of Open Access Journals (Sweden)

    Jussara Rocha Batista

    2012-12-01

    Full Text Available Some psychological approaches distinguish behavioral self-control from emotional self-control, the latter being approached with the reference to inside events controlled by the individual himself. This paper offers some directions to a behavior-analytic approach of what has been referred to as emotional self-control. According to Behavior Analysis, no new process is found in emotional self-control, but components that are additional to those found in behavioral self-control, which require appropriate treatment. The paper highlights some determinants of behavioral repertoires taken as instances of emotional self-control: the social context in which self-control is produced and maintained; the conflicts between consequences for the individual and for the group; and the degree of participation of the motor apparatus in the emission of emotional responses. Keywords: emotional self-control; emotional responses; inner world; behavior analysis.

  7. Feasibility tests of a new all-digital beam control scheme for LEIR

    CERN Document Server

    Angoletta, Maria Elena; Findlay, A; Pedersen, F; CERN. Geneva. AB Department

    2004-01-01

    The new Low Energy Ion Ring (LEIR), to be commissioned at CERN in early 2005, will be a very important element of the LHC lead ions injection chain and will require a new beam control and cavity servoing system. Current plans call for a new all-digital beam control system based on the same technology deployed at Brookhaven National Laboratory (BNL) for the to control the AGS Booster beam. That beam control system, now under development, relies on VME modules and daughter boards based on Digital Signal Processors (DSPs) and Field Programmable Gate Arrays (FPGAs). The DSP provides high throughput processing capabilities and ease of connection with the software layer immediately above, while the daughter boards implement master clock, digital receiver and modulator capabilities. The resulting system is very flexible because is configurable via software and offers multi-processing capabilities and high bandwidth data paths, features that make it very attractive for a beam control implementation. For application t...

  8. Investigation on the use digital controls instead of PID analog controls in the level control of steam generators of nuclear power PWR

    International Nuclear Information System (INIS)

    Alvarenga, Marco Antonio Bayout

    2012-01-01

    The aim of this study is to identify current alternatives for the implementation of digital controllers in the level control of steam generators of nuclear power PWR (Pressurized Water Reaetor). It is intended to identify the types of digital controls that are available from the theoretical and conceptual viewpoints for this purpose. We investigate the advantages and disadvantages of each controller model. From this assessment are pointed the most suitable models in hierarchical scale. This evaluation also serves to suggest possible types of control installation as a whole, where the level control of the steam generators becomes just one of many controls that are part of the plant. In this case, the use of digital controls allows the non-linear and multivariable treatment which is characteristic of complex systems, such as the nuclear power generation. The treatment of nonlinearities and multivariable aspects allows a more detailed study of the stability of these plants when they are subject to transients or several accidents, such as the case of losing external power of transients. In the specific case of steam generators, the instabilities result from the emergence of the shrink and swell phenomenas, depending on the load variations of thermonuclear plant. The application of several types and digital controllers, considering these inherent characteristics of the level control of steam generators, allows to infer which types of controllers are more appropriate to treat instabilities of this type and to make conjectures in its use for the cases of more complex instabilities, considering the integration of all nucleus-plant controls.

  9. Automated hazard analysis of digital control systems

    International Nuclear Information System (INIS)

    Garrett, Chris J.; Apostolakis, George E.

    2002-01-01

    Digital instrumentation and control (I and C) systems can provide important benefits in many safety-critical applications, but they can also introduce potential new failure modes that can affect safety. Unlike electro-mechanical systems, whose failure modes are fairly well understood and which can often be built to fail in a particular way, software errors are very unpredictable. There is virtually no nontrivial software that will function as expected under all conditions. Consequently, there is a great deal of concern about whether there is a sufficient basis on which to resolve questions about safety. In this paper, an approach for validating the safety requirements of digital I and C systems is developed which uses the Dynamic Flowgraph Methodology to conduct automated hazard analyses. The prime implicants of these analyses can be used to identify unknown system hazards, prioritize the disposition of known system hazards, and guide lower-level design decisions to either eliminate or mitigate known hazards. In a case study involving a space-based reactor control system, the method succeeded in identifying an unknown failure mechanism

  10. Self-interference digital holography with a geometric-phase hologram lens.

    Science.gov (United States)

    Choi, KiHong; Yim, Junkyu; Yoo, Seunghwi; Min, Sung-Wook

    2017-10-01

    Self-interference digital holography (SIDH) is actively studied because the hologram acquisition under the incoherent illumination condition is available. The key component in this system is wavefront modulating optics, which modulates an incoming object wave into two different wavefront curvatures. In this Letter, the geometric-phase hologram lens is introduced in the SIDH system to perform as a polarization-sensitive wavefront modulator and a single-path beam splitter. This special optics has several features, such as high transparency, a modulation efficiency up to 99%, a thinness of a few millimeters, and a flat structure. The demonstration system is devised, and the numerical reconstruction results from an acquired complex hologram are presented.

  11. Immunochromatographic diagnostic test analysis using Google Glass.

    Science.gov (United States)

    Feng, Steve; Caire, Romain; Cortazar, Bingen; Turan, Mehmet; Wong, Andrew; Ozcan, Aydogan

    2014-03-25

    We demonstrate a Google Glass-based rapid diagnostic test (RDT) reader platform capable of qualitative and quantitative measurements of various lateral flow immunochromatographic assays and similar biomedical diagnostics tests. Using a custom-written Glass application and without any external hardware attachments, one or more RDTs labeled with Quick Response (QR) code identifiers are simultaneously imaged using the built-in camera of the Google Glass that is based on a hands-free and voice-controlled interface and digitally transmitted to a server for digital processing. The acquired JPEG images are automatically processed to locate all the RDTs and, for each RDT, to produce a quantitative diagnostic result, which is returned to the Google Glass (i.e., the user) and also stored on a central server along with the RDT image, QR code, and other related information (e.g., demographic data). The same server also provides a dynamic spatiotemporal map and real-time statistics for uploaded RDT results accessible through Internet browsers. We tested this Google Glass-based diagnostic platform using qualitative (i.e., yes/no) human immunodeficiency virus (HIV) and quantitative prostate-specific antigen (PSA) tests. For the quantitative RDTs, we measured activated tests at various concentrations ranging from 0 to 200 ng/mL for free and total PSA. This wearable RDT reader platform running on Google Glass combines a hands-free sensing and image capture interface with powerful servers running our custom image processing codes, and it can be quite useful for real-time spatiotemporal tracking of various diseases and personal medical conditions, providing a valuable tool for epidemiology and mobile health.

  12. Advanced Light Source beam diagnostics systems

    International Nuclear Information System (INIS)

    Hinkson, J.

    1993-10-01

    The Advanced Light Source (ALS), a third-generation synchrotron light source, has been recently commissioned. Beam diagnostics were very important to the success of the operation. Each diagnostic system is described in this paper along with detailed discussion of its performance. Some of the systems have been in operation for two years. Others, in the storage ring, have not yet been fully commissioned. These systems were, however, working well enough to provide the essential information needed to store beam. The devices described in this paper include wall current monitors, a beam charge monitor, a 50 ohm Faraday cup, DC current transformers, broad-hand striplines, fluorescence screens, beam collimators and scrapers, and beam position monitors. Also, the means by which waveforms are digitized and displayed in the control room is discussed

  13. Diagnostic development for current density profile control at KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Ko, J., E-mail: jinseok@nfri.re.kr [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); University of Science and Technology, Daejeon 34113 (Korea, Republic of); Chung, J. [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); Messmer, M.C.C. [Department of Applied Physics, Eindhoven University of Technology, Eindhoven (Netherlands)

    2016-11-01

    Highlights: • The motional Stark effect (MSE) diagnostic installed at KSTAR. • Engineering challenges and solutions on the design and fabrication of the front optics housing and filter modules. • Characterization of the bandpass filters and the responses to polarized light. - Abstract: The current density profile diagnostics are critical for the control of the steady-state burning plasma operations. A multi-channel motional Stark effect (MSE) diagnostic system has been implemented for the measurements of the internal magnetic field structures that constrain the magnetic equilibrium reconstruction to accurately produce the tokamak safety factor and current density profiles for the Korea Superconducting Tokamak Advanced Research (KSTAR). This work presents the design and fabrication of the front optics and the filter modules and the calibration activities for the MSE diagnostic at KSTAR.

  14. Current Controller for Multi-level Front-end Converter and Its Digital Implementation Considerations on Three-level Flying Capacitor Topology

    Science.gov (United States)

    Tekwani, P. N.; Shah, M. T.

    2017-10-01

    This paper presents behaviour analysis and digital implementation of current error space phasor based hysteresis controller applied to three-phase three-level flying capacitor converter as front-end topology. The controller is self-adaptive in nature, and takes the converter from three-level to two-level mode of operation and vice versa, following various trajectories of sector change with the change in reference dc-link voltage demanded by the load. It keeps current error space phasor within the prescribed hexagonal boundary. During the contingencies, the proposed controller takes the converter in over modulation mode to meet the load demand, and once the need is satisfied, controller brings back the converter in normal operating range. Simulation results are presented to validate behaviour of controller to meet the said contingencies. Unity power factor is assured by proposed controller with low current harmonic distortion satisfying limits prescribed in IEEE 519-2014. Proposed controller is implemented using TMS320LF2407 16-bit fixed-point digital signal processor. Detailed analysis of numerical format to avoid overflow of sensed variables in processor, and per-unit model implementation in software are discussed and hardware results are presented at various stages of signal conditioning to validate the experimental setup. Control logic for the generation of reference currents is implemented in TMS320LF2407A using assembly language and experimental results are also presented for the same.

  15. Development of a digital guidance and control law for steep approach automatic landings using modern control techniques

    Science.gov (United States)

    Halyo, N.

    1979-01-01

    The development of a digital automatic control law for a small jet transport to perform a steep final approach in automatic landings is reported along with the development of a steady-state Kalman filter used to provide smooth estimates to the control law. The control law performs the functions of localizer and glides capture, localizer and glideslope track, decrab, and place. The control law uses the microwave landing system position data, and aircraft body-mounted accelerators, attitude and attitude rate information. The results obtained from a digital simulation of the aircraft dynamics, wind conditions, and sensor noises using the control law and filter developed are described.

  16. Validation of the Gambling Disorder Screening Questionnaire, a self-administered diagnostic questionnaire for gambling disorder based on the DSM-5 criteria.

    Science.gov (United States)

    Villella, Corrado; Pascucci, Marco; de Waure, Chiara; Bellomo, Antonello; Conte, Gianluigi

    2016-01-01

    The DSM-5 has modified the diagnostic criteria for gambling disorder, compared to the fourth edition of the manual; new diagnostic instruments are therefore needed. This study evaluated the psychometric characteristics of the Gambling Disorder Screening Questionnaire (GDSQ), a self-report questionnaire based on the DSM-IV and DSM-5 criteria for Gambling Disorder, measuring its validity, internal consistency, and submitting the questionnaire to a principal components analysis. 71 patients from a gambling disorder outpatient clinic and 70 controls were evaluated with the GDSQ, the South Oaks Gambling Screen (SOGS), and a psychiatric interview. The test showed a good sensibility, specificity, internal consistency, concurrent validity with the SOGS. The exclusion of the “illegal acts” item, and the lowering of the cut-off score to four positive items, as suggested by the DSM-5 criteria, improved the test sensibility and internal consistency. The GDSQ can be considered a useful screening test for Gambling Disorder. Furthermore, this study confirms the improved diagnostic accuracy of the criteria listed in the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders, compared to the previous edition.

  17. Sleep deprivation, low self-control, and delinquency: a test of the strength model of self-control.

    Science.gov (United States)

    Meldrum, Ryan C; Barnes, J C; Hay, Carter

    2015-02-01

    Recent work provides evidence that sleep deprivation is positively related to delinquency. In this study, we draw on Baumeister and colleagues' strength model of self-control to propose an explanation for this association. Specifically, we argue that low self-control is the construct that bridges the relationship between sleep deprivation and delinquency. To test the proposed model, we examine survey data drawn from a longitudinal multi-city cohort study of adolescents who were followed from birth through age 15 (N = 825; 50% female; 82% non-Hispanic white, 59% two-parent nuclear family). The results from regression models using latent factors indicate: sleep deprivation is positively related to low self-control; low self-control is positively related to delinquency; and the relationship between sleep deprivation and delinquency is indirect and operates through low self-control. Impressively, these relationships emerged when accounting for potential background sources of spuriousness, including neighborhood context, depressive symptoms, parenting practices, unstructured socializing with peers, and prior delinquency. Implications and directions for future research are discussed.

  18. Digital radiography detectors - A technical overview: Part 1

    International Nuclear Information System (INIS)

    Lanca, Luis; Silva, Augusto

    2009-01-01

    During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided

  19. A new kind of user interface for controlling MFTF diagnostics

    International Nuclear Information System (INIS)

    Preckshot, G.; Mead, J.; Saroyan, R.

    1983-01-01

    The Mirror Fusion Test Facility (MFTF) at Lawrence Livermore National Laboratory is faced with the problem of controlling a multitude of plasma diagnostics instruments from a central, multiprocessor computer facility. A 16-bit microprocessor-based workstation allows each physicist entree into the central multiprocessor, which consists of nine Perkin-Elmer 32-bit minicomputers. The workstation provides the user interface to the larger system, with display graphics, windowing, and a physics notebook. Controlling a diagnostic is now equivalent to making entries into a traditional physics notebook

  20. Auxiliary controller for time-to-digital converter module readout

    International Nuclear Information System (INIS)

    Ermolin, Yu.V.

    1992-01-01

    The KD-225 auxiliary controller for time-to-digital converter module readout in the SUMMA crate is described. After readout and preliminary processing the data are written in the P-140 buffer memory module. The controller is used in the FODS-2 experimental setup data acquisition system. 12 refs.; 1 fig

  1. Control and monitoring of doses to patients in a team of digital mammography; Control y seguimiento de las dosis a pacientes en un equipo de mamografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Agulla Otero, M.; Torres Cabrera, R.; Hernando Gonzalez, I.

    2013-07-01

    In recent years is widespread use of imaging devices digital mammography. One of the advantages associated with this scanning is the ability to access a large amount of information contained in the headwaters of own digital images. The exploitation of this information allows the calculation of doses received by patients. This paper describes the methodology employed for this purpose and are presented the results of the control and monitoring of doses given in a digital mammography equipment. (Author)

  2. [Application and prospect of digital technology in the field of orthodontics].

    Science.gov (United States)

    Zhou, Y H

    2016-06-01

    The three-dimensional(3D)digital technology has brought a revolutionary change in diagnostic planning and treatment strategy of orthodontics. Acquisition of 3D image data of the hard and soft tissues of the patients, diagnostic analysis and treatment prediction, and ultimately the individualized orthodontic appliance, will become the development trend and workflow of the 3D orthodontics. With the development of 3D digital technology, the traditional plaster model has been gradually replacing by 3D digital models. Meanwhile, 3D facial soft tissue scan and cone-beam CT scan have been gradually applied to clinical orthodontics, making it possible to get 3D virtual anatomical structure for patients. With the help of digital technology, the diagnostic process is much easier for orthodontist. However how to command the whole digital workflow and put it into practice in the daily work is still a long way to go. The purpose of this article is to enlighten the orthodontists interested in digital technology and discuss the future of digital orthodontics in China.

  3. A digital controller for the Omega West Reactor

    International Nuclear Information System (INIS)

    Minor, M.M.; Kaufman, M.D.; Smith, T.W.

    1992-05-01

    A new nuclear reactor control system for the Omega West Reactor (OWR) has been designed to replace the aging and hard to maintain controller presently installed. The controller uses single board computers, digital and analog input and output modules, and stepping motor indexers installed on a standard bus (VME bus). The eight poison control rod drive motors are replaced with stepping motors. The control algorithm for the OWR was not changed in order to expedite approval for installation. This report presents the results of the development of the new control system. Included in the report are copies of some of the software that drives the new controller

  4. Beam control and diagnostic functions in the NIF transport spatial filter

    International Nuclear Information System (INIS)

    Holdener, F.R.; Ables, E.; Bliss, E.S.

    1996-10-01

    Beam control and diagnostic systems are required to align the National Ignition Facility (NIF) laser prior to a shot as well as to provide diagnostics on 192 beam lines at shot time. A design that allows each beam's large spatial filter lenses to also serve as objective lenses for beam control and diagnostic sensor packages helps to accomplish the task at a reasonable cost. However, this approach also causes a high concentration of small optics near the pinhole plane of the transport spatial filter (TSF) at the output of each beam. This paper describes the optomechanical design in and near the central vacuum vessel of the TSF

  5. Regulatory accessibility and social influences on state self-control.

    Science.gov (United States)

    vanDellen, Michelle R; Hoyle, Rick H

    2010-02-01

    The current work examined how social factors influence self-control. Current conceptions of state self-control treat it largely as a function of regulatory capacity. The authors propose that state self-control might also be influenced by social factors because of regulatory accessibility. Studies 1 through 4 provide evidence that individuals' state self-control is influenced by the trait and state self-control of salient others such that thinking of others with good trait or state self-control leads to increases in state self-control and thinking of others with bad trait or state self-control leads to decreases in state self-control. Study 5 provides evidence that the salience of significant others influences both regulatory accessibility and state self-control. Combined, these studies suggest that the effects of social influences on state self-control occur through multiple mechanisms.

  6. 2D:4D digit ratio predicts delay of gratification in preschoolers.

    Directory of Open Access Journals (Sweden)

    Sergio Da Silva

    Full Text Available We replicate the Stanford marshmallow experiment with a sample of 141 preschoolers and find a correlation between lack of self-control and 2D:4D digit ratio. Children with low 2D:4D digit ratio are less likely to delay gratification. Low 2D:4D digit ratio may indicate high fetal testosterone. If this hypothesis is true, our finding means high fetal testosterone children are less likely to delay gratification.

  7. Retrofit of new digital control systems in existing power stations

    International Nuclear Information System (INIS)

    Smith, J.E.; Baird, C.F.

    1986-01-01

    With the notable exception of the Canadian CANDU nuclear power stations, little use has been made of digital control in North American nuclear stations. Recently, however, there has been renewed interest in such systems within the nuclear industry in response to demands for better ergonomics in control room design and the obsolescence of control equipment whose fundamental design has changed little in 20 yr. Early in 1985, Atomic Energy of Canada Limited was asked by New Brunswick Power to advise on the redesign of the control systems for two fossil-fired generating stations, Coleson Cove and Courtenay Bay Unit 4. Coleson Cove is to be converted from oil to coal firing with consequent extensive control system changes and Courtenay Bay Unit 4 required a low-cost solution to the problem of relocating its control room from the existing isolated location to the combined control center used by units 1, 2, and 3. In both cases, the recommended solution involves the retrofit of state-of-the-art digital control systems. Although the units involved are nonnuclear the experience is applicable

  8. Digital Speed Cascade Control, using Scilab / Xcos Environment

    Directory of Open Access Journals (Sweden)

    Petru Chioncel

    2016-10-01

    Full Text Available This paper presents an application of digital cascade control implemented in Scilab / Xcos environment, using a P type regulator for the position adjustment circuit, a PI controller for the speed circuit adjustment; the current respectively moments control circuits are rendered by elements of PT1 type. On this basis the program is done in Scilab and the related signal block diagram implemented in Xcos; through simulation, the step response of the system is analyzed for different sampling times.

  9. Interface language for diagnostic control

    International Nuclear Information System (INIS)

    Matone, J.T.

    1985-01-01

    The neutron multichannel collimator diagnostic on TFTR is run with the help of a keyboard-entered interface language. The language allows the user to interact with the real-time control and data analysis systems in a consistent and efficient manner. It uses a vocabulary that can be abbreviated into one character commands which the proficient user may concatenate into command words. This allows the user to progress quickly from a novice to an expert operating mode. A similar type interface language could be applied to many interactive applications accepting keyboard inputs

  10. Digital servo control of random sound test excitation. [in reverberant acoustic chamber

    Science.gov (United States)

    Nakich, R. B. (Inventor)

    1974-01-01

    A digital servocontrol system for random noise excitation of a test object in a reverberant acoustic chamber employs a plurality of sensors spaced in the sound field to produce signals in separate channels which are decorrelated and averaged. The average signal is divided into a plurality of adjacent frequency bands cyclically sampled by a time division multiplex system, converted into digital form, and compared to a predetermined spectrum value stored in digital form. The results of the comparisons are used to control a time-shared up-down counter to develop gain control signals for the respective frequency bands in the spectrum of random sound energy picked up by the microphones.

  11. A real-time digital control, data acquisition and analysis system for the DIII-D multipulse Thomson scattering diagnostic

    International Nuclear Information System (INIS)

    Greenfield, C.M.; Campbell, G.L.; Carlstrom, T.N.; DeBoo, J.C.; Hsieh, C.-L.; Snider, R.T.; Trost, P.K.

    1990-10-01

    A VME-based real-time computer systems for laser control, data acquisition and analysis for the DIII-D multipulse Thomson scattering diagnostic is described. The laser control task requires precise timing of up to 8 Nd:YAG lasers, each with an average firing rate of 20 Hz. A cpu module in real-time multiprocessing computer system will operate the lasers with evenly staggered laser pulses or in a ''burst mode'', where all available (fully charged) lasers can be fired at 50--100 μsec intervals upon receipt of an external event trigger signal. One of more cpu modules, along with a LeCroy FERA (Fast Encoding and Readout ADC) system, will perform real-time data acquisition and analysis. Partial electron temperature and density profiles will be available for plasma feedback control within 1 msec following each laser pulse. The VME-based computer system consists of 2 or more target processor modules (25 MHz Motorola 68030) running the VMEexec real-time operating system connected to a Unix based host system (also a 68030). All real-time software is fully interrupt driven to maximize system efficiency. Operator interaction and (non real-time) data analysis takes place on a MicroVAX 3400 connected via DECnet. 17 refs., 1 fig

  12. Remote interferometry by digital holography for shape control

    Science.gov (United States)

    Baumbach, Torsten; Osten, Wolfgang; Falldorf, Claas; Jueptner, Werner P. O.

    2002-06-01

    Modern production requires more and more effective methods for the inspection and quality control at the production place. Outsourcing and globalization result in possible large distances between co-operating partners. This may cause serious problems with respect to the just-in-time exchange of information and the response to possible violations of quality standards. Consequently new challenges arise for optical measurement techniques especially in the field of industrial shape control. A possible solution for these problems can be delivered by a technique that stores optically the full 3D information of the objects to be compared and where the data can be transported over large distances. In this paper we describe the progress in implementing a new technique for the direct comparison of the shape and deformation of two objects with different microstructure where it is not necessary that both samples are located at the same place. This is done by creating a coherent mask for the illumination of the sample object. The coherent mask is created by Digital Holography to enable the instant access to the complete optical information of the master object at any wanted place. The transmission of the digital master holograms to this place can be done via digital telecommunication networks. The comparison can be done in a digital or analogue way. Both methods result in a disappearance of the object shape and the appearance of the shape or deformation difference between the two objects only. The analogue reconstruction of the holograms with a liquid crystal spatial light modulator can be done by using the light modulator as an intensity modulator or as an phase modulator. The reconstruction technique and the space bandwidth of the light modulator will influence the quality of the result. Therefore the paper describes the progress in applying modern spatial light modulators and digital cameras for the effective storage and optical reconstruction of coherent masks.

  13. A multi-process model of self-regulation: influences of mindfulness, integrative self-knowledge and self-control in Iran.

    Science.gov (United States)

    Ghorbani, Nima; Watson, P J; Farhadi, Mehran; Chen, Zhuo

    2014-04-01

    Self-regulation presumably rests upon multiple processes that include an awareness of ongoing self-experience, enduring self-knowledge and self-control. The present investigation tested this multi-process model using the Five-Facet Mindfulness Questionnaire (FFMQ) and the Integrative Self-Knowledge and Brief Self-Control Scales. Using a sample of 1162 Iranian university students, we confirmed the five-factor structure of the FFMQ in Iran and documented its factorial invariance across males and females. Self-regulatory variables correlated negatively with Perceived Stress, Depression, and Anxiety and positively with Self-Esteem and Satisfaction with Life. Partial mediation effects confirmed that self-regulatory measures ameliorated the disturbing effects of Perceived Stress. Integrative Self-Knowledge and Self-Control interacted to partially mediate the association of Perceived Stress with lower levels of Satisfaction with Life. Integrative Self-Knowledge, alone or in interaction with Self-Control, was the only self-regulation variable to display the expected mediation of Perceived Stress associations with all other measures. Self-Control failed to be implicated in self-regulation only in the mediation of Anxiety. These data confirmed the need to further examine this multi-process model of self-regulation. © 2014 International Union of Psychological Science.

  14. Validation of Digital Microscopy Compared With Light Microscopy for the Diagnosis of Canine Cutaneous Tumors.

    Science.gov (United States)

    Bertram, Christof A; Gurtner, Corinne; Dettwiler, Martina; Kershaw, Olivia; Dietert, Kristina; Pieper, Laura; Pischon, Hannah; Gruber, Achim D; Klopfleisch, Robert

    2018-07-01

    Integration of new technologies, such as digital microscopy, into a highly standardized laboratory routine requires the validation of its performance in terms of reliability, specificity, and sensitivity. However, a validation study of digital microscopy is currently lacking in veterinary pathology. The aim of the current study was to validate the usability of digital microscopy in terms of diagnostic accuracy, speed, and confidence for diagnosing and differentiating common canine cutaneous tumor types and to compare it to classical light microscopy. Therefore, 80 histologic sections including 17 different skin tumor types were examined twice as glass slides and twice as digital whole-slide images by 6 pathologists with different levels of experience at 4 time points. Comparison of both methods found digital microscopy to be noninferior for differentiating individual tumor types within the category epithelial and mesenchymal tumors, but diagnostic concordance was slightly lower for differentiating individual round cell tumor types by digital microscopy. In addition, digital microscopy was associated with significantly shorter diagnostic time, but diagnostic confidence was lower and technical quality was considered inferior for whole-slide images compared with glass slides. Of note, diagnostic performance for whole-slide images scanned at 200× magnification was noninferior in diagnostic performance for slides scanned at 400×. In conclusion, digital microscopy differs only minimally from light microscopy in few aspects of diagnostic performance and overall appears adequate for the diagnosis of individual canine cutaneous tumors with minor limitations for differentiating individual round cell tumor types and grading of mast cell tumors.

  15. Beyond the Trial: Systematic Review of Real-World Uptake and Engagement With Digital Self-Help Interventions for Depression, Low Mood, or Anxiety.

    Science.gov (United States)

    Fleming, Theresa; Bavin, Lynda; Lucassen, Mathijs; Stasiak, Karolina; Hopkins, Sarah; Merry, Sally

    2018-06-06

    Digital self-help interventions (including online or computerized programs and apps) for common mental health issues have been shown to be appealing, engaging, and efficacious in randomized controlled trials. They show potential for improving access to therapy and improving population mental health. However, their use in the real world, ie, as implemented (disseminated) outside of research settings, may differ from that reported in trials, and implementation data are seldom reported. This study aimed to review peer-reviewed articles reporting user uptake and/or ongoing use, retention, or completion data (hereafter usage data or, for brevity, engagement) from implemented pure self-help (unguided) digital interventions for depression, anxiety, or the enhancement of mood. We conducted a systematic search of the Scopus, Embase, MEDLINE, and PsychINFO databases for studies reporting user uptake and/or usage data from implemented digital self-help interventions for the treatment or prevention of depression or anxiety, or the enhancement of mood, from 2002 to 2017. Additionally, we screened the reference lists of included articles, citations of these articles, and the titles of articles published in Internet Interventions, Journal of Medical Internet Research (JMIR), and JMIR Mental Health since their inception. We extracted data indicating the number of registrations or downloads and usage of interventions. After the removal of duplicates, 970 papers were identified, of which 10 met the inclusion criteria. Hand searching identified 1 additional article. The included articles reported on 7 publicly available interventions. There was little consistency in the measures reported. The number of registrants or downloads ranged widely, from 8 to over 40,000 per month. From 21% to 88% of users engaged in at least minimal use (eg, used the intervention at least once or completed one module or assessment), whereas 7-42% engaged in moderate use (completing between 40% and 60% of

  16. ISTTOK control system upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Ivo S., E-mail: ivoc@ipfn.ist.utl.pt; Duarte, Paulo; Fernandes, Horácio; Valcárcel, Daniel F.; Carvalho, Pedro J.; Silva, Carlos; Duarte, André S.; Neto, André; Sousa, Jorge; Batista, António J.N.; Carvalho, Bernardo B.

    2013-10-15

    Highlights: •ISTTOK fast controller. •All real-time diagnostic and actuators were integrated in the control platform. •100 μs control cycle under the MARTe framework. •The ISTTOK control system upgrade provides reliable operation with an improved operational space. -- Abstract: The ISTTOK tokamak (Ip = 4 kA, BT = 0.5 T, R = 0.46 m, a = 0.085 m) is one of the few tokamaks with regular alternate plasma current (AC) discharges scientific programme. In order to improve the discharge stability and to increase the number of AC discharge cycles a novel control system was developed. The controller acquires data from 50 analog-to-digital converter (ADC) channels of real-time diagnostics and measurements: tomography, Mirnov coils, interferometer, electric probes, sine and cosine probes, bolometer, current delivered by the power supplies, loop voltage and plasma current. The system has a control cycle of 100 μs during which it reads all the diagnostics connected to the advanced telecommunications computing architecture (ATCA) digitizers and sends the control reference to ISTTOK actuators. The controller algorithms are executed on an Intel{sup ®} Q8200 chip with 4 cores running at 2.33 GHz and connected to the I/O interfaces through an ATCA based environment. The real-time control system was programmed in C++ on top of the Multi-threaded Application Real-Time executor (MARTe). To extend the duration of the AC discharges and the plasma stability a new magnetising field power supply was commissioned and the horizontal and vertical field power supplies were also upgraded. The new system also features a user-friendly interface based on HyperText Markup Language (HTML) and Javascript to configure the controller parameters. This paper presents the ISTTOK control system and the consequent update of real-time diagnostics and actuators.

  17. ISTTOK control system upgrade

    International Nuclear Information System (INIS)

    Carvalho, Ivo S.; Duarte, Paulo; Fernandes, Horácio; Valcárcel, Daniel F.; Carvalho, Pedro J.; Silva, Carlos; Duarte, André S.; Neto, André; Sousa, Jorge; Batista, António J.N.; Carvalho, Bernardo B.

    2013-01-01

    Highlights: •ISTTOK fast controller. •All real-time diagnostic and actuators were integrated in the control platform. •100 μs control cycle under the MARTe framework. •The ISTTOK control system upgrade provides reliable operation with an improved operational space. -- Abstract: The ISTTOK tokamak (Ip = 4 kA, BT = 0.5 T, R = 0.46 m, a = 0.085 m) is one of the few tokamaks with regular alternate plasma current (AC) discharges scientific programme. In order to improve the discharge stability and to increase the number of AC discharge cycles a novel control system was developed. The controller acquires data from 50 analog-to-digital converter (ADC) channels of real-time diagnostics and measurements: tomography, Mirnov coils, interferometer, electric probes, sine and cosine probes, bolometer, current delivered by the power supplies, loop voltage and plasma current. The system has a control cycle of 100 μs during which it reads all the diagnostics connected to the advanced telecommunications computing architecture (ATCA) digitizers and sends the control reference to ISTTOK actuators. The controller algorithms are executed on an Intel ® Q8200 chip with 4 cores running at 2.33 GHz and connected to the I/O interfaces through an ATCA based environment. The real-time control system was programmed in C++ on top of the Multi-threaded Application Real-Time executor (MARTe). To extend the duration of the AC discharges and the plasma stability a new magnetising field power supply was commissioned and the horizontal and vertical field power supplies were also upgraded. The new system also features a user-friendly interface based on HyperText Markup Language (HTML) and Javascript to configure the controller parameters. This paper presents the ISTTOK control system and the consequent update of real-time diagnostics and actuators

  18. Principles and applications of the digital luminescent radiography

    International Nuclear Information System (INIS)

    Doehring, W.; Prokop, M.; Bergh, B.

    1986-01-01

    Digital luminescent radiography is a novel technique for routine diagnostics that allows the establishment of digital projection radiograms. Two goals are pursued: Best possible utilisation of the image data contained in the radiation field, and integration of these data into a digital communication system. (orig.) [de

  19. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  20. Impact of digital prosthodontic planning on dental esthetics: Biometric analysis of esthetic parameters.

    Science.gov (United States)

    Abduo, Jaafar; Bennamoun, Mohammed; Tennant, Marc; McGeachie, John

    2016-01-01

    Improving dental esthetics is a main objective of prosthodontic treatment. Recently, digital diagnostic waxing has been proposed as an alternative to conventional diagnostic waxing; however, the impact on esthetics has not been evaluated. The purpose of this study was to evaluate the impact of diagnostic waxing on biometric esthetic variables and to compare the esthetic outcome achieved by digital waxing with conventional waxing. Three biometric variables were evaluated: perceived frontal proportion (PFP), width/height (W:H) ratio, and symmetry. Maxillary casts of 13 patients were collected. All of them had maxillary anterior teeth that required prosthodontic treatment. Two forms of diagnostic waxing were executed: conventional and digital waxing. Measurements of the esthetic variables were conducted digitally. For the PFP, a frontal image was made and the width of each tooth was measured. Subsequently, the PFP values of the lateral incisor to central incisor and of the canine to central incisor were calculated. In addition, the height and width of each tooth was measured to calculate the W:H ratio. Using the previous measurements, the symmetry between the right and left sides was determined. No consistent or recurrent PFP was detected for any cast. The diagnostic waxing did not alter the PFP of the pretreatment casts. The diagnostic waxing had restored the W:H ratio to what is assumed to be a natural ratio. An improvement in symmetry was detected after the diagnostic waxing and was more prominent after the digital waxing. However, no significant difference was found between the 2 diagnostic waxing methods. The 2 diagnostic waxing methods influenced the esthetic variables of the anterior maxillary teeth and yielded similar outcomes. Digital waxing appears to be a reasonable alternative, but further investigations are needed to ensure its practicality. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights