WorldWideScience

Sample records for self-deploying stent design

  1. A new self-expandable aortic valved stent deployed above native leaflets for aortic insufficiency: an in vitro study.

    Science.gov (United States)

    Huang, H; Zhou, Y; Shao, J; Cai, J; Mei, Y; Wang, Y

    2012-12-01

    The aim of this paper was to develop a new self-expandable aortic valved stent following the shape of the sinus of Valsalva, which can be deployed above native leaflets for aortic regurgitation, and study it's effect on coronary artery flow when orthotopic implantation in and above native leaflets. New self-expandable aortic valved stent consist of nitinol stent and bovine pericardium, and was designed following the shape of the sinus of Valsalva, the bovine pericardium was tailed as native leaflet. Thirty-six swine hearts were divided into three equal groups of twelve. In Group A (N.=12), the new self-expandable aortic valved stents deployed in native leaflets. In Group B (N.=12), the new self-expandable aortic valved stents deployed above native leaflets. In Group C (N.=12), the cylinder-like valved stents deployed only in native leaflets. The measurements of each coronary flow rate and endoscopic inspections were repeated post-implantation. In Group A and C, valve implantation in native leaflets resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after new self-expandable aortic valved stent placement. Endoscopic inspections showed that in group A and C the native leaflets sandwiched between valved stent and aortic wall, whereas, in group B the native leaflets were under the artificial leaflets. Two kinds of stents deployed in native leaflets affect left and right coronary flows significantly. No significant effect was found when the new self-expandable aortic valved stent deployed above native leaflets. This new self-expandable aortic valved stent can be deployed above the native leaflets, which avoids the obstruction of native leaflets on coronary flow.

  2. Post-biliary sphincterotomy bleeding despite covered metallic stent deployment

    Directory of Open Access Journals (Sweden)

    Gianfranco Donatelli

    2016-05-01

    Full Text Available Objectives: Several endoscopic techniques have been proposed for the management of post-sphincterotomy bleeding. Lately, self-expandable metal stents deployment has gained popularity especially as a rescue therapy when other endoscopic techniques fail. Methods-results: We report the case report of a massive post-sphincterotomy bleeding in a patient with a self-expandable metal stent in the biliary tree. Despite the presence of a correctly positioned self-expandable metal stent, a new endoscopic session was required to control the bleeding. Conclusions: Self-expandable metal stent may be useful to manage post-endoscopic sphincterotomy bleeding. However, up to now there is no specifically designed self-expandable metal stent for such complication. Large new designed self-expandable metal stent may be a useful tool for biliary endoscopist.

  3. Computational design analysis for deployment of cardiovascular stents

    International Nuclear Information System (INIS)

    Tammareddi, Sriram; Sun Guangyong; Li Qing

    2010-01-01

    Cardiovascular disease has become a major global healthcare problem. As one of the relatively new medical devices, stents offer a minimally-invasive surgical strategy to improve the quality of life for numerous cardiovascular disease patients. One of the key associative issues has been to understand the effect of stent structures on its deployment behaviour. This paper aims to develop a computational model for exploring the biomechanical responses to the change in stent geometrical parameters, namely the strut thickness and cross-link width of the Palmaz-Schatz stent. Explicit 3D dynamic finite element analysis was carried out to explore the sensitivity of these geometrical parameters on deployment performance, such as dog-boning, fore-shortening, and stent deformation over the load cycle. It has been found that an increase in stent thickness causes a sizeable rise in the load required to deform the stent to its target diameter, whilst reducing maximum dog-boning in the stent. An increase in the cross-link width showed that no change in the load is required to deform the stent to its target diameter, and there is no apparent correlation with dog-boning but an increased fore-shortening with increasing cross-link width. The computational modelling and analysis presented herein proves an effective way to refine or optimise the design of stent structures.

  4. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H. [Robert Janker Klinik, Bonn (Germany); Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany); Miloslavski, E.; Lowens, S.; Reinartz, J. [Robert Janker Klinik, Bonn (Germany); Liebig, T.; Kuehne, D. [Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany)

    2005-03-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  5. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    International Nuclear Information System (INIS)

    Henkes, H.; Miloslavski, E.; Lowens, S.; Reinartz, J.; Liebig, T.; Kuehne, D.

    2005-01-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  6. Stent Design Affects Femoropopliteal Artery Deformation.

    Science.gov (United States)

    MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey

    2018-03-23

    Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.

  7. Plastic strains during stent deployment have a critical influence on the rate of corrosion in absorbable magnesium stents.

    Science.gov (United States)

    Galvin, Emmet; Cummins, Christy; Yoshihara, Shoichiro; Mac Donald, Bryan J; Lally, Caitríona

    2017-08-01

    Magnesium stents are a promising candidate in the emerging field of absorbable metallic stents (AMSs). In this study, the mechanical and corrosion performance of dog-bone specimens and a specific stent design of a magnesium alloy, WE43, are assessed experimentally in terms of their corrosion behaviour and mechanical integrity. It is shown that plastic strains that are induced in the struts of the stent during stent deployment have a critical influence in directing subsequent corrosion behaviour within the material. In addition, the deployment and scaffolding characteristics of the magnesium stent are elucidated and contrasted with those of a commercial stainless steel stent. The magnesium stent is found to support higher levels of cyclic strain amplitude than the stainless steel stent, even prior to degradation, and this may play a role in reducing in-stent restenosis. This study provides new insights into the experimental performance of a current AMS design and material whilst demonstrating the critical influence of plastic strain on the corrosion performance and scaffolding ability of an AMS.

  8. Application of a novel retrievable self-expanding stent in intracranial aneurysm treatment

    International Nuclear Information System (INIS)

    Yang Zhigang; Liu Jianmin; Xu Yi; Huang Qinghai; Hong Bo; Zhao Wenyuan; Zhao Rui

    2008-01-01

    Objective: To assess the value of a novel retrievable self-expanding stent system (LEO) in intracranial aneurysm treatment. Methods: 43 patients with 44 intracranial aneurysms treated with LEO stent were retrospectively analized, including 16 aneurysms with single-stent deployment, 25 with stent-assisted technique, 2 with double-stent deployment and one with double-stent assisted coils. Follow up was carried out through imaging and clinical course. Results: The stent was easy for repositioning and all the stents were delivered successfully, except 1 stent with unsatisfactory position, 1 with acute in-stent thrombosis. During follow up, 1 case showed chronic in-stent thrombus and one with intimal hyperplasia. 22 aneurysms got compact coiled during procedure. Among 29 follow up cases, 72.4% aneurysms were cured or improved, 13.8% were stable and three dissection aneurysms enlarged within short period and two patients died. Conclusion: The new retrievable self-expanding stent (LEO), with the advantages of controlled delivery, easy deployment and choice for various types is a valuable system for vascular reconstruction of intracranial aneurysm with thrombosis. (authors)

  9. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  10. Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study.

    Science.gov (United States)

    Jiao, Dechao; Huang, Kai; Zhu, Ming; Wu, Gang; Ren, Jianzhuang; Wang, Yanli; Han, Xinwei

    2017-01-01

    Whether unilateral or bilateral drainage should be performed for malignant hilar biliary obstruction remains a matter of debate. Although a Y-stent with a central wide-open mesh facilitates bilateral stent placement, it has its own limitations. This study aims to evaluate the feasibility and efficacy of a newly designed Y-configured bilateral self-expanding metallic stent (SEMS) for the treatment of hilar biliary obstruction. In this retrospective study, 14 consecutive patients with unresectable malignant hilar biliary obstruction (Bismuth type II or higher), who underwent placement of a newly designed Y-configured bilateral SEMS for hilar biliary obstruction from April 2013 to March 2015, were included into this study. Data on technical success, clinical success, stent patency, complications and patient survival were collected. Technical and clinical success was 100 and 92.9 %, respectively. Mean serum bilirubin level was significantly decreased 1 month after stent placement (P hilar biliary obstruction using port docking deployment.

  11. Outcome of self-expandable metallic stent deployment in patients with malignant gastroduodenal outlet obstruction and Niti-S and WallFlex comparison: a multicenter retrospective clinical study.

    Science.gov (United States)

    Kato, Hironari; Kawamoto, Hirofumi; Matsumoto, Kazuya; Moriyama, Ichiro; Kamada, Hideki; Tsutsumi, Koichiro; Goto, Daisuke; Fukuba, Nobuhiko; Kato, Kiyohito; Sonoyama, Hiroki; Isomoto, Hajime; Okada, Hiroyuki

    2016-08-01

    Several studies report on the outcomes of self-expandable metallic stents (SEMSs) deployment for malignant gastric outlet obstruction (GOO). However, data was mostly based on the analysis of single-center studies including only a small number of patients. This study aimed to evaluate clinical outcomes after the deployment of SEMS in patients with malignant GOO and to compare the clinical outcomes of two metallic stents with different designs. Altogether 125 consecutive patients from five institutions were included. Clinical outcomes were evaluated according to technical success, clinical success, stent patency period, survival period and complications. A comparison of clinical outcomes between Niti-S pyloric/duodenal and WallFlex duodenal stents was also undertaken. Rates for clinical and technical success were 100% and 92.0%, respectively. The median stent patency and survival periods were 72.0 days (range 3-775 days) and 75.0 days (range 3-775 days), respectively. The rate of overall adverse events was 28.8%. The rate of stent dysfunction was 16.8%, and that of adverse events, except stent dysfunction was 12.0%. Massive bleeding occurred in two patients as a late complication. The clinical success rate for Niti-S stent was significantly higher than that for WallFlex stent (96.2% vs 84.8%, P = 0.023). We successfully deployed a SEMS in malignant GOO. The selection of a SEMS with a lower axial force may be important for patients to resume the oral food intake. Additionally, consideration must be given to the appropriate management of fatal bleeding as a late complication. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  12. Anchoring barbs and balloon expandable stents: what is the risk of perforation and failed stent deployment?

    Science.gov (United States)

    Bown, M J; Harrison, G J; How, T V; Brennan, J A; Fisher, R K; Vallabhaneni, S R; McWilliams, R G

    2012-09-01

    Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Guo Jinhe [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Teng Gaojun [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)]. E-mail: gjteng@vip.sina.com; Zhu Guangyu [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Shicheng [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Deng Gang [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Jie [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)

    2007-02-15

    Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the targeted esophageal segment in all rabbits. Neither {sup 125}I seeds dislodged from the stent during the deployment, nor they did during the follow-up period. The greatest (16.2 Gy) absorbed dose was found in the tissue 10 mm from {sup 125}I seeds at 8 weeks. Slight epithelial hyperplasia on the stent surface and submucosal inflammatory process developed at 2 weeks, which reached the peak at 8 weeks after the procedure. Significant thickness of the esophageal muscular layer was found at 8 weeks only in the groups with {sup 125}I seeds. On radiologic follow-up, moderate strictures on both ends of the stents developed at 4 weeks and became severe at 8 weeks after the procedure in all groups. Conclusion: Deployment of a self-expandable stent loaded with {sup 125}I seeds is technically feasible and safe within the first 8 weeks. Acute and subacute radiotolerance of the treated esophagus and its adjacent tissues by {sup 125}I seeds is well preserved in a healthy rabbit model.

  14. Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex.

    Science.gov (United States)

    Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J

    2017-07-01

    We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.

  15. Use of nitinol self-expandable stents in 26 dogs with tracheal collapse.

    Science.gov (United States)

    Beranek, J; Jaresova, H; Rytz, U

    2014-02-01

    A study was designed to describe a novel approach to the treatment of tracheal collapse (TC) in dogs using self-expandable nitinol stents. Medical records were reviewed retrospectively for 26 client owned dogs in which nitinol stents were deployed. The entire length of trachea was supported independently of the extent of TC. Two overlapping stents were used instead of one in cases where one stent was not spanning the entire trachea adequately. The diameter of the cranial radiolucent portion of trachea, just behind the cricoid cartilage, was measured as a specific landmark to select the appropriate size of the stent. Two self-expandable nitinol stents were inserted in 9 of 26 dogs; the trachea in the rest of the cases was supported with only one stent. A follow up tracheoscopy was performed in 10 of 26 cases with recurrent clinical signs. Secondary tracheal stenosis in these cases was caused by stent fracture, granuloma or excessive stent shortening. Additional stents were placed successfully to expand the stenotic lumen. A support of the entire trachea may decrease risk of nitinol fracture at the end of the implant. Long term clinical improvement (25 of 26 dogs, 96 %) is comparable with the results of other studies.

  16. Study design and rationale of the 'Balloon-Expandable Cobalt Chromium SCUBA Stent versus Self-Expandable COMPLETE-SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS-ILIAC Trial) Trial': study protocol for a randomized controlled trial.

    Science.gov (United States)

    Choi, Woong Gil; Rha, Seung Woon; Choi, Cheol Ung; Kim, Eung Ju; Oh, Dong Joo; Cho, Yoon Hyung; Park, Sang Ho; Lee, Seung Jin; Hur, Ae Yong; Ko, Young Guk; Park, Sang Min; Kim, Ki Chang; Kim, Joo Han; Kim, Min Woong; Kim, Sang Min; Bae, Jang Ho; Bong, Jung Min; Kang, Won Yu; Seo, Jae Bin; Jung, Woo Yong; Cho, Jang Hyun; Kim, Do Hoi; Ahn, Ji Hoon; Kim, Soo Hyun; Jang, Ji Yong

    2016-06-25

    The self-expandable COMPLETE™ stent (Medtronic) has greater elasticity, allowing it to regain its shape after the compression force reduces, and has higher trackability, thus is easier to maneuver through tortuous vessels, whereas the balloon-expandable SCUBA™ stent (Medtronic) has higher radial stiffness and can afford more accurate placement without geographic miss, which is important in aortoiliac bifurcation lesions. To date, there have been no randomized control trials comparing efficacy and safety between the self-expanding stent and balloon-expandable stent in advanced atherosclerotic iliac artery disease. The purpose of our study is to examine primary patency (efficacy) and incidence of stent fracture and geographic miss (safety) between two different major representative stents, the self-expanding nitinol stent (COMPLETE-SE™) and the balloon-expanding cobalt-chromium stent (SCUBA™), in stenotic or occlusive iliac arterial lesions. This trial is designed as a prospective, randomized, multicenter trial to demonstrate a noninferiority of SCUBA™ stent to COMPLETE-SE™ stent following balloon angioplasty in iliac arterial lesions, and a total of 280 patients will be enrolled. The primary end point of this study is the rate of primary patency in the treated segment at 12 months after intervention as determined by catheter angiography, computed tomography angiography, or duplex ultrasound. The SENS-ILIAC trial will give powerful insight into whether the stent choice according to deployment mechanics would impact stent patency, geographic miss, or stent fracture in patients undergoing stent implantation in iliac artery lesions. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT01834495 ), registration date: May 8, 2012.

  17. Comparison of Self-Expanding Polyethylene Terephthalate and Metallic Stents Implanted in Porcine Iliac Arteries

    International Nuclear Information System (INIS)

    Wilczek, Krzysztof; Scheerder, Ivan de; Wang Kai; Verbeken, Eric; Piessens, Jan

    1996-01-01

    Purpose: Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). Methods: Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deployment was studied angiographically and with intravascular ultrasound immediately after stent implantation. The angiographic stented lumen diameter was measured using quantitative vessel analysis before, immediately after stenting, and at 6-week follow-up. Cross-section histopathology and area morphometry were performed. Results: Immediately poststenting, intravascular ultrasound revealed proximal dislocation of 5 of the 13 PET stents, whereas all metal stents were firmly embedded at the implantation site. At 6-week follow-up, three of the remaining PET stents were totally or subtotally occluded by organized thrombus, whereas all metal stents were patent. Compared with immediately poststenting, the angiographic lumen diameter within the five remaining PET stents was reduced by 30%, and that of the metallic stents was virtually unaltered (p < 0.02). This observation was confirmed by postmortem morphometry, wherein the PET-stented vessel segments a diameter stenosis of 40% was measured vs only 9% in the metallic stents (p < 0.0001). Conclusion: PET-stent deployment is difficult to control due to the lack of radiopacity of this stent. PET stents seem to be more thrombogenic and lead to significantly more neointimal proliferation than metallic stents

  18. Tracheal Self-Expandable Metallic Stents: A Comparative Study of Three Different Stents in a Rabbit Model.

    Science.gov (United States)

    Serrano, Carolina; Lostalé, Fernando; Rodríguez-Panadero, Francisco; Blas, Ignacio de; Laborda, Alicia; de Gregorio, Miguel Angel

    2016-03-01

    The objective of this study was to assess tracheal reactivity after the deployment of different self-expandable metal stents (SEMS). Forty female New Zealand rabbits were divided into four groups. Three groups received three different SEMS: steel (ST), nitinol (NiTi), or nitinol drug-eluting stent (DES); the fourth group was the control group (no stent). Stents were deployed percutaneously under fluoroscopic guidance. Animals were assessed by multi-slice, computed tomography (CT) scans, and tracheas were collected for anatomical pathology (AP) study. Data from CT and AP were statistically analyzed and correlated. The DES group had the longest stenosis (20.51±14.08mm vs. 5.84±12.43 and 6.57±6.54mm in NiTi and ST, respectively, day 30; Pstent. CT was more effective in detecting wall thickening (positive correlation of 68.9%; Pstent, while DES caused significant lesions that may be related to drug dosage. This type of DES stent is therefore not recommended for the treatment of tracheobronchial stenosis. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.

  19. An intriguing design concept to enhance the pulsatile fatigue life of self-expanding stents.

    Science.gov (United States)

    Hsiao, Hao-Ming; Yin, Ming-Ting

    2014-02-01

    Intravascular stenting has emerged as the primary treatment for vascular diseases and has received great attention from the medical community since its introduction two decades ago. The endovascular self-expanding stent is used to treat peripheral artery diseases; however, once implanted, these stents suffer from various cyclic motions caused by pulsatile blood pressure and daily activities. Due to this challenging environment, fatigue performance has become a critical issue for stent design. In this paper, a simple yet intriguing concept of stent design aimed at enhancing pulsatile fatigue life is investigated. The concept of this design is to shift the highly concentrated stresses/strains away from the crown and re-distribute them along the stress-free bar arm by tapering its strut width. Finite element models were developed to evaluate the mechanical integrity and pulsatile fatigue resistance of the stent to various loading conditions. Results show that the fatigue safety factor jumped to 2.5-3.0 times that of the standard stent with constant strut width. This is astonishing considering that the stent profile and scaffolding were not compromised. The findings of this paper provide an excellent approach to the optimization of future stent design to greatly improve stent fatigue performance.

  20. Evolution of patency rates of self-expandable bare metal stents for endovascular treatment of femoro-popliteal arterial occlusive disease: Does stent design matter?

    Science.gov (United States)

    Treitl, Karla Maria; Woerner, Benedikt; Schinner, Regina; Czihal, Michael; Notohamiprodjo, Susan; Hoffmann, Ulrich; Treitl, Marcus

    2017-09-01

    To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P stent and the highest TLR_12M for the CC stent. The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.

  1. Flow Velocities After Carotid Artery Stenting: Impact of Stent Design. A Fluid Dynamics Study in a Carotid Artery Model with Laser Doppler Anemometry

    International Nuclear Information System (INIS)

    Greil, Oliver; Kleinschmidt, Thomas; Weiss, Wolfgang; Wolf, Oliver; Heider, Peter; Schaffner, Silvio; Gianotti, Marc; Schmid, Thomas; Liepsch, Dieter; Berger, Hermann

    2005-01-01

    Purpose. To study the influence of a newly developed membrane stent design on flow patterns in a physiologic carotid artery model. Methods. Three different stents were positioned in silicone models of the carotid artery: a stainless steel stent (Wall-stent), a nitinol stent (SelfX), and a nitinol stent with a semipermeable membrane (MembraX). To increase the contact area of the membrane with the vessel wall, another MembranX model was modified at the outflow tract. The membrane consists of a biocompatible silicone-polyurethane copolymer (Elast-Eon) with a pore size of 100 μm. All stents were deployed across the bifurcation and the external carotid artery origin. Flow velocity measurements were performed with laser Doppler anemometry (LDA), using pulsatile flow conditions (Re = 220; flow 0.39 l/min; flow rate ratio ICA:ECA = 70:30) in hemodynamically relevant cross-sections. The hemodynamic changes were analyzed by comparing velocity fluctuations of corresponding flow profiles. Results. The flow rate ratio ICA:ECA shifted significantly from 70/30 to 73.9/26.1 in the MembraX and remained nearly unchanged in the SelfX and Wallstent. There were no changes in the flow patterns at the inflow proximal to the stents. In the stent no relevant changes were found in the SelfX. In the Wallstent the separation zone shifted from the orifice of the ICA to the distal end of the stent. Four millimeters distal to the SelfX and the Wallstent the flow profile returned to normal. In the MembraX an increase in the central slipstreams was found with creation of a flow separation distal to the stent. With a modification of the membrane this flow separation vanished. In the ECA flow disturbances were seen at the inner wall distal to the stent struts in the SelfX and the Wallstent. With the MembraX a calming of flow could be observed in the ECA with a slight loss of flow volume. Conclusions. Stent placement across the carotid artery bifurcation induces alterations of the physiologic flow

  2. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren

    2004-01-01

    Endoscopic deployment of self-expanding metal stents offers an alternative to surgical intervention in rectocolonic obstructions. Reported clinical failures in the literature are all related to the site of stent placement. We report a case of serious intra-abdominal disease after technically...... and clinically successful stent deployment: a potentially dangerous situation of which the surgeon should be aware. A previously healthy 72-year-old female was referred to our department with symptoms of an obstructing colorectal tumor. Successful stent placement resulted in resolution of the obstructive......, probably caused by ischemic conditions developed before stent-decompression of the colon was revealed during the operation. The patient died in the postoperative course. We discuss the observation of patients treated with self-expanding metal stents based on the selection-strategy used to allocate patients...

  3. Insertion of Self-Expandable Nitinol Stents Without Previous Balloon Angioplasty Reduces Restenosis Compared with PTA Prior to Stenting

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Stenram, Unne; Cwikiel, Wojciech

    2002-01-01

    Purpose: To compare the development of intimal hyperplasia after deployment of a self-expanding nitinol stent with and without previous percutaneous transluminal balloon angioplasty (PTA), with the results after PTA alone. Methods: In nine healthy pigs, the iliac arteries were divided into three groups: group 1 (n = 6 arteries) was treated with PTA; group 2 n 6)with insertion of self-expanding stents after PTA; and group 3 (n = 6) with stent insertion without previous PTA. After 8 weeks the vessels were examined with intravascular ultrasonography,histologic examination and morphometric analysis. Results: Although the injury index in group 1 (0.17± 0.57) was lower (p <0.05) than in group 2 (0.26 ± 0.06) and group 3 (0.26 ± 0.08), PTA-treated arteries showed significantly (p <0.05) reduced mean luminal gain (0.53 ± 2.84) compared with arteries treated with PTA prior to stenting (2.58 ± 1.38) and compared with stenting alone (4.65 ±5.34). Stenting after PTA resulted in a higher (p<0.05) restenosis index (2.63 ± 1.06) compared with stenting without PTA (1.35 ± 0.59). Group 2 also had a significantly thicker intimap <0.05) and 83% and 74% higher intima/mediaratio (p <0.05) compared with groups 1 and 3, respectively. Conclusion: Insertion of a self-expandable nitinol stent without previous PTA results in less intimalhyperplasia than if PTA is performed prior to stenting, suggesting that direct stenting can be used in angioplasty sessions with a favorable outcome

  4. Primary stent placement for recanalization of iliac artery occlusions: Using a self-expanding spiral stent

    International Nuclear Information System (INIS)

    Kim, Jae-Kyu; Kim, Yun-Hyeon; Chung, Sang-Yeung; Kang, Heoung-Keun

    1999-01-01

    Purpose: To report the clinical results for recanalizations of an occluded iliac artery by a self-expanding spiral stent.Methods: We attempted to recanalize 36 iliac artery occlusions in 34 patients [33 men, 1 woman, aged 51-75 years (average 61.6 years)]. The average lesion length was 6.92 cm (range 1-14 cm). The patients's chief complaints were intermittent claudication and resting pain. Fontaine classification was assigned before and after the procedure. Technical and clinical success were also analyzed.Results: Forty-five stents were successfully deployed in 34 patients. All 36 lesions (13 in the external iliac artery, 12 in the common iliac artery, and 11 in both) were patently recanalized on angiography. The follow-up period ranged from 6 months to 36 months (mean 11.9 months). Fourteen stents (39%) with incomplete expansion were dilated with a balloon catheter. Good technical (100%) and clinical (94%) results were obtained. The only complication was one hematoma at the puncture site. Reocclusions were noted in two lesions (5%) at 1 week and 15 months, respectively.Conclusion: A self-expanding spiral stent is a safe and effective device for recanalization of an iliac artery occlusion as the primary stent without any previous intervention.

  5. Outcomes of Prosthetic Hemodialysis Grafts after Deployment of Bare Metal versus Covered Stents at the Venous Anastomosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Charles Y., E-mail: charles.kim@duke.edu; Tandberg, Daniel J.; Rosenberg, Michael D.; Miller, Michael J.; Suhocki, Paul V.; Smith, Tony P. [Duke University Medical Center, Division of Vascular and Interventional Radiology (United States)

    2012-08-15

    Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metal stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.

  6. Outcomes of Prosthetic Hemodialysis Grafts after Deployment of Bare Metal versus Covered Stents at the Venous Anastomosis

    International Nuclear Information System (INIS)

    Kim, Charles Y.; Tandberg, Daniel J.; Rosenberg, Michael D.; Miller, Michael J.; Suhocki, Paul V.; Smith, Tony P.

    2012-01-01

    Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metal stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.

  7. Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study

    Science.gov (United States)

    Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe

    2016-05-01

    In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.

  8. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    Energy Technology Data Exchange (ETDEWEB)

    Vajda, Zsolt, E-mail: Z.Vajda@klinikum-stuttgart.de; Guethe, Thomas, E-mail: T.Guethe@klinikum-stuttgart.de; Perez, Marta Aguilar, E-mail: M.Aguilar@klinikum-stuttgart.de; Kurre, Wiebke, E-mail: w.kurre@klinikum-stuttgart.de [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany); Schmid, Elisabeth, E-mail: ESchmid@klinikum-stuttgart.de; Baezner, Hansjoerg, E-mail: H.Baezner@klinikum-stuttgart.de [Klinikum Stuttgart, Klinik fuer Neurologie, Neurozentrum (Germany); Henkes, Hans, E-mail: hhhenkes@aol.com [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany)

    2013-04-15

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  9. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren

    2004-01-01

    Endoscopic deployment of self-expanding metal stents offers an alternative to surgical intervention in rectocolonic obstructions. Reported clinical failures in the literature are all related to the site of stent placement. We report a case of serious intra-abdominal disease after technically...... and clinically successful stent deployment: a potentially dangerous situation of which the surgeon should be aware. A previously healthy 72-year-old female was referred to our department with symptoms of an obstructing colorectal tumor. Successful stent placement resulted in resolution of the obstructive...... condition. Three days after stent deployment, x-ray examinations revealed a small-bowel obstruction and emergency surgery was performed. Intraoperative findings demonstrated a segment of ileum fixated to the tumor in the small pelvis, resulting in the obstructive condition. Furthermore, a cecal perforation...

  10. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    International Nuclear Information System (INIS)

    Vajda, Zsolt; Güthe, Thomas; Perez, Marta Aguilar; Kurre, Wiebke; Schmid, Elisabeth; Bäzner, Hansjörg; Henkes, Hans

    2013-01-01

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54–86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  11. Medium-term follow-up after deployment of ultraflex expandable metallic stents to manage endobronchial pathology.

    Science.gov (United States)

    Madden, Brendan P; Park, John E S; Sheth, Abhijat

    2004-12-01

    Between March 1997 and March 2004 we deployed 80 Ultraflex metallic expandable stents (Boston Scientific, Waterson, MA) in 69 patients under direct vision using rigid bronchoscopy. We report our medium- to long-term experience in patients for whom these stents were deployed. To date 15 patients have been followed for more than 1 year (median 41 months, range 12 to 83 months) after stent deployment. Indications for stenting in these patients were neoplasia (5), stricture (5), airway malacia (1), iatrogenic tracheal tear (1), and compression from an aortic aneurysm (1), a right interrupted aortic arch (1), and a right brachiocephalic artery aneurysm with tracheomalacia (1). Ten tracheal stents (9 covered, 1 uncovered) and 10 bronchial stents (8 uncovered, 2 covered) were inserted, and 5 patients received two stents. Five of these patients experienced no long-term problems. Complications included troublesome halitosis (5), which was difficult to treat despite various antibiotic regimes; granulation tissue formation above and below the stent that was successfully treated with low-power Nd:YAG laser therapy (7); and metal fatigue (1). We did not encounter stent migration. We conclude that Ultraflex expandable metallic stents have an important role in the management of selected patients with diverse endobronchial pathologies and are well tolerated in the long-term. Although associated granulation tissue can be successfully treated with Nd:YAG laser, halitosis can be a difficult problem to address.

  12. A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion

    International Nuclear Information System (INIS)

    Liebig, Thomas; Henkes, Hans; Reinartz, Joerg; Miloslavski, Elina; Kuehne, Dietmar

    2006-01-01

    The endovascular treatment of large and broad-necked aneurysms may require the use of a remodelling balloon or a stent system to achieve proper occlusion while maintaining the patency of the parent vessel. With the advent of self-expanding stents that can be delivered through a microcatheter, this kind of treatment has improved and problems with the previously used balloon expandable stents have largely been overcome. However, rigidity, insufficient trackability, and limited or non-existent retrievability may still restrict the application of self-expanding stents in some situations. Recently, a stent system with a new and different design has been introduced. This stent is highly flexible, fully retrievable, and can be delivered through a standard 0.021-inch microcatheter without a wire. We describe the first nine cases of stent-assisted coil occlusion of intracranial aneurysms with the use of this stent system. Between May and June of 2004, nine patients with large or broad-necked aneurysms were treated in two endovascular centres. The anatomy of the aneurysms and parent vessels, technical details of the procedure, performance of the stent system, and follow-up results were evaluated. In all procedures, the SOLO stent could be introduced without difficulty, in one procedure after positioning of a different self-expanding stent system had failed due to vessel tortuosity. Overlapping stents were placed in one patient and stent retrieval or repositioning was successfully performed in two procedures. There was no interference or limitation of subsequent coil occlusion after stenting. With regard to the stent, immediate postprocedure and follow-up angiograms were unremarkable in terms of thromboembolic events and signs of intimal hyperplasia. From our experience, we conclude that the SOLO stent shows satisfactory performance overall. Its unique design gives the stent properties that may help overcome some of the difficulties experienced with other self

  13. Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium.

    Science.gov (United States)

    Cabrera, María Sol; Oomens, Cees W J; Baaijens, Frank P T

    2017-04-01

    A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Feasibility of using bulk metallic glass for self-expandable stent applications.

    Science.gov (United States)

    Praveen Kumar, Gideon; Jafary-Zadeh, Mehdi; Tavakoli, Rouhollah; Cui, Fangsen

    2017-10-01

    Self-expandable stents are widely used to restore blood flow in a diseased artery segment by keeping the artery open after angioplasty. Despite the prevalent use of conventional crystalline metallic alloys, for example, nitinol, to construct self-expandable stents, new biomaterials such as bulk metallic glasses (BMGs) are being actively pursued to improve stent performance. Here, we conducted a series of analyses including finite element analysis and molecular dynamics simulations to investigate the feasibility of using a prototypical Zr-based BMG for self-expandable stent applications. We model stent crimping of several designs for different percutaneous applications. Our results indicate that BMG-based stents with diamond-shaped crowns suffer from severe localization of plastic deformation and abrupt failure during crimping. As a possible solution, we further illustrate that such abrupt failure could be avoided in BMG-based stents without diamond shape crowns. This work would open a new horizon for a quest toward exploiting superior mechanical and functional properties of metallic glasses to design future stents. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1874-1882, 2017. © 2016 Wiley Periodicals, Inc.

  15. Treatment of intracranial wide neck aneurysm with neuroform self-expanding stent combined with spring coils

    International Nuclear Information System (INIS)

    Bai Weixing; Jiang Xifeng; Li Tianxiao; Zhai Shuiting; Xue Jiangyu; Wang Ziliang; Cao Huicun

    2008-01-01

    Objective: To evaluate the preliminary experience of the combined self-expanding neurovascular stent (Neuroform stent) with detachable coils in the management of intracranial wide neck aneurysms. Methods: Self-expanding neurovascular stents with detachable coils were used in treating 27 intracranial wide neck aneurysms of 25 patients including cavernous segment ICA aneurysms in 3, ophthalmic arterial anemysm in 1, PcomA in 18, AcomA in 2, MCAM1 in 1, MCA bifurcation in 1, and basilar trunk in 1. Among them, 2 cases consisted of multi-aneurysms, 2 aneurysms coincide with absolute wide neck (> 4 mm) and 6 with comparatively wide neck (> 7 mm). Nemoform stents were deployed across the neck of aneurysm and detachable coils were released to embolize the aneurysm through stent mesh. Results: Twenty-six Neuroform stents were successfully deployed in 25 patients including 4 Neuroform II stents, and 22 Neurofom III stents(all combined with spring coils). Total occlusion was achieved in 7 patients with residual neck in 9 nearly complete occlusion and partial occlusion in 11. 2 patients were rebleeding and other 2 showed intra-stent thrombosis during the operations. The latter 2 included 1 with post-operative limb paraplegia and 1 died. Still another 1 had transient ischemic attack after the operation. Twenty-three patient recovered well. Twenty-four patients were under clinical followed up from 0.5 to 28 months with an average of 10.8 months. There was no bleeding. Three patients were angiographically followed up for 3-6 months after the procedure, with only 1 case of in-stent thrombosis and no change in other 2 aneurysms with neck remnant. Conclusions: The Neuroform stent is technically feasible and safe for treating intracranial wide neck aneurysms unsuitable for clipping because of its prevention for coil protruding into parent artery. The long term effect still need to be further investigated. (authors)

  16. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  17. How to design the optimal self-expandable oesophageal metallic stents: 22 years of experience in 645 patients with malignant strictures.

    Science.gov (United States)

    Na, Han Kyu; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Kang, Min Kyoung; Lee, Jongjin; Oh, Se Jin

    2013-03-01

    To evaluate the clinical efficacy and safety of self-expandable metallic stent (SEMS) placement for malignant oesophageal strictures and their relationship with stent designs. Seven generations of SEMS were used to treat 645 consecutive patients with oesophageal strictures. Logistic regression models were constructed to identify predictive factors associated with complications. Stent placement was technically successful in 641 of 645 patients (99.4%). The clinical success rate was 95.5%. There were 260 (40.3%) complications after stent placement. Due to complications, 68 stents were removed; 66 of 68 stents (97.1%) were removed successfully. Stainless steel (SS) stents (odds ratio [OR] 4.18; 95% confidence interval [CI] 2.10, 8.32) and radiation therapy (RT) before stent placement (OR 4.23; CI 2.02, 8.83) were significantly associated with severe pain. Flared ends (OR 9.63; CI 3.38, 27.43), stricture length stent diameter stent migration. Polyurethane membranes were associated with more frequent tumour ingrowth than polytetrafluoroethylene (PTFE) membranes (P = 0.002). Despite the relatively high complication rate, retrievable self-expandable PTFE-covered nitinol stents equipped with a head and a tail appeared to be an effective treatment for malignant oesophageal strictures.

  18. Polyurethane-Covered Self-expandable Nitinol Stent for Malignant Biliary Obstruction: Preliminary Results

    International Nuclear Information System (INIS)

    Han, Young-Min; Hwang, Seung-Bae; Lee, Soo-Teik; Lee, Jeong-Min; Chung, Gyung-Ho

    2002-01-01

    Purpose: To evaluate the immediate and long-term results in ten patients with malignant biliary obstruction using a polyurethane-covered, self-expandable nitinol stent.Methods: A nitinol stent, fully covered with high-elasticity polyurethane, with an unconstrained diameter of 10 mm and a total length of 60-80 mm, was placed transhepatically under fluoroscopic guidance in ten patients. The length of the biliary obstruction varied between 30-50 mm. The follow-up examination included a clinical assessment, serum bilirubin measurement, and ultrasound examinations at one-month intervals in all patients. Results: Initial stent deployment was successful in eight patients. Two patients experienced proximal migration,which was solved by insertion of two, uncovered Wallstents. One patient had the stent removed after two weeks because of severe nausea and vomiting. One patient had delayed migration of the covered stent after 40 weeks. The follow-up duration was 3-40 weeks (Mean: 16.9 weeks). Seven patients died(3-26 weeks) and three patients survived (24-40 weeks). The bilirubin measurements in all patients had significantly decreased one week after stent insertion. The levels of amylase and lipase had did not increase after stent insertion. Conclusions: Apolyurethane-covered, self-expandable nitinol stent can be used effectively and safely in the treatment of malignant biliary obstruction. The preliminary results are favorable, but there is a need for further large studies to determine both long-term survival and patency

  19. Treatment of Post-Stent Gastroesophageal Reflux by Anti-Reflux Z-Stent

    International Nuclear Information System (INIS)

    Davies, Roger Philip; Kew, Jacqueline; Byrne, Peter D.

    2000-01-01

    Severe symptoms of heartburn and retrosternal pain consistent with gastro-esophageal reflux (GER) developed in a patient following placement of a conventional self-expanding 16-24-mm-diameter x 12-cm-long esophageal stent across the gastroesophageal junction to treat an obstructing esophageal carcinoma. A second 18-mm-diameter x 10-cm-long esophageal stent with anti-reflux valve was deployed coaxially and reduced symptomatic GER immediately. Improvement was sustained at 4-month follow-up. An anti-reflux stent can be successfully used to treat significant symptomatic GER after conventional stenting

  20. The Bolton Treovance abdominal stent-graft: European clinical trial design.

    Science.gov (United States)

    Chiesa, R; Riambau, V; Coppi, G; Zipfel, B; Llagostera, S; Marone, E M; Kahlberg, A

    2012-10-01

    Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.

  1. Factors leading to tracheobronchial self-expandable metallic stent fracture.

    Science.gov (United States)

    Chung, Fu-Tsai; Lin, Shu-Min; Chen, Hao-Cheng; Chou, Chun-Liang; Yu, Chih-Teng; Liu, Chien-Ying; Wang, Chun-Hua; Lin, Horng-Chyuan; Huang, Chien-Da; Kuo, Han-Pin

    2008-11-01

    This retrospective study was to determine factors that contribute to self-expandable metallic stent fracture in patients with tracheobronchial disease. From 2001 to 2006, 139 patients (age, 62.1 +/- 15.4 years; range, 23-87 years) with benign (n = 62) and malignant (n = 77) tracheobronchial disease received 192 Ultraflex (Boston Scientific, Natick, Mass) self-expandable metallic stents (98 in patients with benign disease and 94 in patients with malignant disease). Seventeen fractured self-expandable metallic stents were found; the incidence was 12.2% (17/139 patients) among patients with tracheobronchial disease. Tortuous airway (odds ratio, 4.06; 95% confidence interval, 1.04-18.34; P = .04) independently predicted self-expandable metallic stent fracture. Most self-expandable metallic stent fractures (64.7%, 11/17) were detected 500 to 1000 days after self-expandable metallic stent implantation. Clinical presentations for patients with fractured self-expandable metallic stents included dyspnea exacerbation (70.6%, 12/17) and cough (23.5%, 4/17). Self-expandable metallic stent fracture is not uncommon in patients with tracheobronchial disease. Tortuous airway is an independent predictor for it. Although management of the fractured self-expandable metallic stent in our study was feasible and safe, self-expandable metallic stents should be restricted to a more select population.

  2. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  3. Self-Expandable Metal Stents and Trans-stent Light Delivery: Are Metal Stents and Photodynamic Therapy Compatible?

    Science.gov (United States)

    Wang, Luo-Wei; Li, Li-Bo; Li, Zhao-Shen; Chen, Yang K; Hetzel, Fred W.; Huang, Zheng

    2008-01-01

    Background and Objectives: Obstructive non-small cell lung cancer and obstructive esophageal cancer are US FDA approved indications of photodynamic therapy (PDT). The usefulness of PDT for the treatment of cholangiocarcinoma is currently under clinical investigation. Endoscopic stenting for lumen restoration is a common palliative intervention for those indications. It is important to assess whether self-expandable metal stents are compatible with trans-stent PDT light delivery. Study Design/Materials and Methods: Direct effects of various components of metal biliary (n = 2), esophageal (n = 2), and bronchial (n = 1) stents on PDT light transmittance and distribution were examined using a point or linear light source (630 or 652 nm diode laser). Resected pig biliary duct and esophageal wall tissues were used to examine the feasibility of PDT light delivery through the fully expanded metal stents. Results: While using a point light source, the metal components (thread and joint) of the stent could cause a significant shadow effect. The liner material (polytetrafluoroethylene or polyurethane) could cause various degrees of light absorption. When the stent was covered with a thin layer of biliary duct and esophageal tissues containing all wall layers, the shadow effect could be mitigated due to tissue scattering. Conclusions: This study clearly demonstrates that it is feasible to combine stenting and PDT for the treatment of luminal lesions. PDT light dose should be adjusted to counteract the reduction of light transmittance caused by the metal and liner materials of stent. PMID:18951422

  4. Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.

    Science.gov (United States)

    Holzapfel, Gerhard A; Stadler, Michael; Gasser, Thomas C

    2005-02-01

    Clinical studies have identified factors such as the stent design and the deployment technique that are one cause for the success or failure of angioplasty treatments. In addition, the success rate may also depend on the stenosis type. Hence, for a particular stenotic artery, the optimal intervention can only be identified by studying the influence of factors such as stent type, strut thickness, geometry of the stent cell, and stent-artery radial mismatch with the wall. We propose a methodology that allows a set of stent parameters to be varied, with the aim of evaluating the difference in the mechanical environment within the wall before and after angioplasty with stenting. Novel scalar quantities attempt to characterize the wall changes inform of the contact pressure caused by the stent struts, and the stresses within the individual components of the wall caused by the stent. These quantities are derived numerically and serve as indicators, which allow the determination of the correct size and type of the stent for each individual stenosis. In addition, the luminal change due to angioplasty may be computed as well. The methodology is demonstrated by using a full three-dimensional geometrical model of a postmortem specimen of a human iliac artery with a stenosis using imaging data. To describe the material behavior of the artery, we considered mechanical data of eight different vascular tissues, which formed the stenosis. The constitutive models for the tissue components capture the typical anisotropic, nonlinear and dissipative characteristics under supra-physiological loading conditions. Three-dimensional stent models were parametrized in such a way as to enable new designs to be generated simply with regard to variations in their geometric structure. For the three-dimensional stent-artery interaction we use a contact algorithm based on smooth contact surfaces of at least C-continuity, which prevents numerical problems known from standard facet-based contact

  5. Self-Expanding Metal Stenting for Palliation of Patients with Malignant Colonic Obstruction

    DEFF Research Database (Denmark)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G

    2012-01-01

    Background. Self-expanding metal stents can alleviate malignant colonic obstruction in incurable patients and avoid palliative stoma surgery. Objective. Evaluate stent effectiveness and safety on palliation of patients with malignant colorectal strictures. Design. Two prospective, one Spanish....... Interventions(s). Self-expanding metal stent placement. Main Outcome Measures. Procedural success, clinical success, and safety. Results. Procedural success was 98.4% (251). Clinical success rates were 87.8% at 30 days, 89.7% at 3 months, 92.8% at 6 months, and 96% at 12 months. Overall perforation rate was 5...... for patients with malignant colonic obstruction should be self-expanding metal stent placement due to high rates of technical success and efficacy in symptom palliation and few complications....

  6. A novel stent inflation protocol improves long-term outcomes compared with rapid inflation/deflation deployment method.

    Science.gov (United States)

    Vallurupalli, Srikanth; Kasula, Srikanth; Kumar Agarwal, Shiv; Pothineni, Naga Venkata K; Abualsuod, Amjad; Hakeem, Abdul; Ahmed, Zubair; Uretsky, Barry F

    2017-08-01

    High-pressure inflation for coronary stent deployment is universally performed. However, the duration of inflation is variable and does not take into account differences in lesion compliance. We developed a standardized "pressure optimization protocol" (POP) using inflation pressure stability rather than an arbitrary inflation time or angiographic balloon appearance for stent deployment. Whether this approach improves long-term outcomes is unknown. 792 patients who underwent PCI using either rapid inflation/deflation (n = 376) or POP (n = 416) between January 2009 and March 2014 were included. Exclusion criteria included PCI for acute myocardial infarction, in-stent restenosis, chronic total occlusion, left main, and saphenous vein graft lesions. Primary endpoint was target vessel failure [TVF = combined end point of target vessel revascularization (TVR), myocardial infarction, and cardiac death]. Outcomes were analyzed in the entire cohort and in a propensity analysis. Stent implantation using POP with a median follow-up of 1317 days was associated with lower TVF compared with rapid inflation/deflation (10.1 vs. 17.8%, P inflation/deflation (10 vs. 18%, P < 0.0001). Stent deployment using POP led to reduced TVF compared to rapid I/D. These results recommend this method to improve long-term outcomes. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. Self-expanding Y stents in the treatment of central airway stenosis: a retrospective analysis.

    Science.gov (United States)

    Gompelmann, Daniela; Eberhardt, Ralf; Schuhmann, Maren; Heussel, Claus P; Herth, Felix J F

    2013-10-01

    Central airway obstruction (CAO) is a life-threatening situation. Stent insertion re-establishes patency of the central airways. Self-expanding metallic Y stents have been available since 2005, widening the spectrum of interventional bronchoscopic techniques. Retrospective analysis of all patients treated for CAO with a self-expanding metallic Y stent at the Thoraxklinik Heidelberg between May 2005 and January 2009. A total of 43 patients aged 26-81 had a metallic Y stent inserted endoscopically for the treatment of CAO; 39 of these patients (90.7%) had CAO due to malignant disease, four patients (9.3%) due to benign disease. In all 43 patients, the Y stent was deployed without any complications. A longitudinal follow up was possible in 32 of the 43 patients. The stents remained in situ for an average of 107.1 days (range 1-640 days). In 29 patients with malignant CAO the stenosis was successfully overcome with a Y stent; 11 of these patients died within 6 weeks following stent insertion. On follow up the remaining 18 patients showed immediate improvement of dyspnoea. Eight out of the 18 patients (44.4%) tolerated the stent without problems, two (11.1%) required further stenting, six (33.3%) had complications such as increased secretions, cough, dyspnoea or granulation tissue formation. The stent was removed in one patient (5.6%) due to increased secretions, and in another (5.6%) as the stent was no longer required due to successful tumour-specific therapy. Placement of Y stents in symptomatic CAO allows for quick relief of symptoms. Severe complications are rare. Stent removal is possible after successful treatment of the primary tumour. However, the prognostic indicator for survival is the underlying malignancy.

  8. The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Yong Hu; Chung, Jin Wook; Choi, Seung Hong; Kim, Kwang Gi; Kim, Hyo Cheol; So, Young Ho; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-05-15

    To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 {+-} 10.82% (type A) and 13.80 {+-} 6.94% (type B) ({rho} < 0.0001)]. Furthermore, the area ratios of the neointimal hyperplasia per area of stent-wire in the given area were 138.38 {+-} 10.84% (type A). 87.58 {+-} 7.36% (type B) ({rho} = 0.0002). In conclusion the interlacing pattern vs. the crossing pattern showed a higher level of neointimal formation than the crossing pattern.

  9. Comparison of covered and uncovered self-expandable stents in the treatment of malignant biliary obstruction.

    Science.gov (United States)

    Flores Carmona, Diana Yamel; Alonso Lárraga, Juan Octavio; Hernández Guerrero, Angélica; Ramírez Solís, Mauro Eduardo

    2016-05-01

    Drainage with metallic stents is the treatment of choice in malignant obstructive jaundice. Technical and clinical success with metallic stents is obtained in over 90% and 80% of cases, respectively. There are self-expandable metallic stents designed to increase permeability. The aim of this study was to describe the results obtained with totally covered self-expandable and uncovered self-expandable metallic stents in the palliative treatment of malignant biliary obstruction. Sixty eight patients with malignant obstructive jaundice secondary to pancreatobiliary or metastatic disease not amenable to surgery were retrospectively included. Two groups were created: group A (covered self-expandable metallic stents) (n = 22) and group B (uncovered self-expandable metallic stents) (n = 46). Serum total bilirubin, direct bilirubin, alkaline phosphatase and gamma glutamyl transferase levels decreased in both groups and no statistically significant difference was detected (p = 0.800, p = 0.190, p = 0.743, p = 0.521). Migration was greater with covered stents but it was not statistically significant either (p = 0.101). Obstruction was greater in the group with uncovered stents but it was not statistically significant either (p = 0.476). There are no differences when using covered self-expandable stents or uncovered self-expandable stents in terms of technical and clinical success or complications in the palliative treatment of malignant obstructive jaundice.

  10. Functional Self-Expandable Metal Stents in Biliary Obstruction

    Science.gov (United States)

    Kwon, Chang-Il; Ko, Kwang Hyun; Hahm, Ki Baik

    2013-01-01

    Biliary stents are widely used not only for palliative treatment of malignant biliary obstruction but also for benign biliary diseases. Each plastic stent or self-expandable metal stent (SEMS) has its own advantages, and a proper stent should be selected carefully for individual condition. To compensate and overcome several drawbacks of SEMS, functional self-expandable metal stent (FSEMS) has been developed with much progress so far. This article looks into the outcomes and defects of each stent type for benign biliary stricture and describes newly introduced FSEMSs according to their functional categories. PMID:24143314

  11. Management of stent dislodgment in coarctoplasty of aorta with three overlapping self-expandable nitinol stents.

    Science.gov (United States)

    Ghazi, Payam; Haji-Zeinali, Ali-Mohammad

    2010-01-01

    We describe a case of native coarctation of aorta managed with three self-expandable nitinol stents. After balloon pre-dilation, the first and second stents were dislodged. The coarcted area was successfully treated with the third stent overlapped with the previous stents. During follow up (30 months), the patient was free of complications. It seems that implantation of multiple overlapping self-expandable stents in aortic coarctation patients, if needed, is safe and possible.

  12. Management of post-gastrectomy anastomosis site obstruction with a self-expandable metallic stent.

    Science.gov (United States)

    Cha, Ra Ri; Lee, Sang Soo; Kim, Hyunjin; Kim, Hong Jun; Kim, Tae-Hyo; Jung, Woon Tae; Lee, Ok Jae; Bae, Kyung Soo; Jeong, Sang-Ho; Ha, Chang Yoon

    2015-04-28

    Post-gastrectomy anastomosis site obstruction is a relatively rare complication after a subtotal gastrectomy. We present a case of a 75-year-old man who underwent a truncal vagotomy, omental patch, gastrojejunostomy, and Braun anastomosis for duodenal ulcer perforation and a gastric outlet obstruction. Following the 10(th) postoperative day, the patient complained of abdominal discomfort and vomiting. We diagnosed post-gastrectomy anastomosis site obstruction by an upper gastrointestinal series and an upper endoscopic examination. We inserted a self-expandable metallic stent (SEMS) at the anastomosis site. The stent was fully expanded after deployment. On the day following the stent insertion, the patient began to eat, and his abdominal discomfort was resolved. This paper describes the successful management of post-gastrectomy anastomosis site obstruction with temporary placement of a SEMS.

  13. Tiny intracranial aneurysms: Endovascular treatment by coil embolisation or sole stent deployment

    International Nuclear Information System (INIS)

    Lu Jun; Liu Jiachun; Wang Lijun; Qi Peng; Wang Daming

    2012-01-01

    Purpose: Tiny intracranial aneurysms pose a significant therapeutic challenge for interventional neuroradiologists. The authors report their preliminary results of endovascular treatment of these aneurysms. Methods: Between January 2002 and December 2009, 52 tiny intracranial aneurysms (defined as ≤3 mm in maximum diameter) in 46 patients (22 men; mean age, 57.9 years) were treated by endosaccular coil embolisation or sole stent deployment in the parent artery. Of 52 aneurysms, 29 had ruptured and 23 remained unruptured. The initial angiographic results, procedural complications, and clinical outcomes were assessed at discharge. Imaging follow-up was performed with cerebral angiography. Results: One aneurysm coiling procedure failed because of unsuccessful micro-catheterization. Forty-three aneurysms were successfully coil embolized, of which complete occlusion was obtained in 14, subtotal occlusion in 18 and incomplete occlusion in 11. The other 8 aneurysms were treated by sole stent deployment in the parent artery. Procedural complications (2 intraprocedural ruptures and 3 thromboembolic events) occurred in 5 (9.6%) of 52 aneurysms, resulting in permanent morbidity in only 1 (2.2%, 1/46) patient. No rebleeding occurred during clinical follow-up (mean duration, 46.7 months). Of the 16 coiled aneurysms that receiving repetitive angiography, 6 initially completely and 3 subtotally occluded aneurysms remained unchanged, 4 initially subtotally and 3 incompletely occluded aneurysms progressed to total occlusion. Five sole stent deployed aneurysms received angiographic follow-up (mean duration, 10.0 months), of which 3 remained unchanged, 1 became smaller and 1 progressed to total occlusion. Conclusion: Endovascular treatment of tiny intracranial aneurysms is technical feasible and relatively safe. Coil embolisation seems to be effective in preventing early recanalisation, whereas sole stenting technique needs further investigation to determine its effectiveness.

  14. The technique study and primary clinical application of inverted Y-shaped self-expandable metal airway stent

    International Nuclear Information System (INIS)

    Han Xinwei; Wu Gang; Ma Ji; Yang Ruimin; Guan Sheng; Ma Nan; Wang Yanli

    2007-01-01

    Objective: To investigate the feasibility and primary therapeutic effect of inverted Y-shaped self-expandable metal stent for complex airway stenosis. Methods: On the standpoint of the peculiar anatomic structure and the pathological changes of complex airway stenosis, we designed the inverted Y-shaped self-expandable metal stent. Under the fluoroscopic guidance, 7 stents were implanted in 7 cases of airway complex stenosis. Results: The inverted Y-shaped self-expandable metal stents were placed seccussfully, with instantaneous relief of dyspnea and improvement of living quality. Conclusion: The placement of inverted Y-shaped self-expandable metal stent is feasible and safe for treating airway complex stenosis. (authors)

  15. Novel characteristics of traction force in biliary self-expandable metallic stents.

    Science.gov (United States)

    Hori, Yasuki; Hayashi, Kazuki; Yoshida, Michihiro; Naitoh, Itaru; Ban, Tesshin; Miyabe, Katsuyuki; Kondo, Hiromu; Nishi, Yuji; Umemura, Shuichiro; Fujita, Yasuaki; Natsume, Makoto; Kato, Akihisa; Ohara, Hirotaka; Joh, Takashi

    2017-05-01

    In recent years, knowledge concerning the mechanical properties of self-expandable metallic stents (SEMS) has increased. In a previous study, we defined traction force and traction momentum and reported that these characteristics are important for optimal stent deployment. However, traction force and traction momentum were represented as relative values and were not evaluated in various conditions. The purpose of the present study was to measure traction force in various situations assumed during SEMS placement. Traction force and traction momentum were measured in non-stricture, stricture, and angled stricture models using in-house equipment. Stricture and angled stricture models had significantly higher traction force and traction momentum than those of the non-stricture model (stricture vs non-stricture: traction force, 7.2 N vs 1.4 N, P stent influenced the traction force. Clinicians should be aware of the transition of the traction force and should schedule X-ray imaging during SEMS placement. © 2017 Japan Gastroenterological Endoscopy Society.

  16. Comparison of Enterprise with Neuroform stent-assisted coiling of intracranial aneurysms.

    Science.gov (United States)

    Kadkhodayan, Yasha; Rhodes, Nicholas; Blackburn, Spiros; Derdeyn, Colin P; Cross, DeWitte T; Moran, Christopher J

    2013-04-01

    The Enterprise stent is the first closed-cell stent designed to treat wide-necked intracranial aneurysms. Advantages of the design can include improvement in keeping coils within an aneurysm and the ability of the stent to be recaptured. We compared the technical and clinical complications of the Enterprise stent with the open-cell Neuroform stent, its primary alternative. Patients undergoing Enterprise and Neuroform stent-assisted aneurysm coiling were enrolled in prospective registries starting in March 2007 and February 2003, respectively. All consecutive patients through December 2011 were included. Deployment success and difficulty, stent movement and misplacement, and procedural complications were compared. Enterprise deployment success was high (108 of 115 attempts, 93.9%) with 102 aneurysms receiving a stent compared with Neuroform (173 of 214 attempts, 80.8%, p = 0.001) with 163 aneurysms. Enterprise was easier to deploy (1.7% vs 15.9% difficult deployment, p Enterprise stent (8.7% vs 1.4%, p = 0.0021). The Enterprise stent enabled treatment of 10 additional aneurysms that could not be treated with Neuroform and had a higher rate of immediate aneurysm occlusion (87.3% vs 73.0%, p = 0.0058). Enterprise was easier to deploy and enabled treatment of additional aneurysms; however, there were more thromboembolic complications. On the basis of these findings, we prefer to use the Neuroform stent first and rely on the Enterprise stent as an easy-to-deliver backup for stent-assisted coiling.

  17. The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent

    International Nuclear Information System (INIS)

    Yin, Yong Hu; Chung, Jin Wook; Choi, Seung Hong; Kim, Kwang Gi; Kim, Hyo Cheol; So, Young Ho; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung

    2008-01-01

    To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 ± 10.82% (type A) and 13.80 ± 6.94% (type B) (ρ < 0.0001)]. Furthermore, the area ratios of the neointimal hyperplasia per area of stent-wire in the given area were 138.38 ± 10.84% (type A). 87.58 ± 7.36% (type B) (ρ = 0.0002). In conclusion the interlacing pattern vs. the crossing pattern showed a higher level of neointimal formation than the crossing pattern

  18. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  19. Designing of self-deploying origami structures using geometrically misaligned crease patterns.

    Science.gov (United States)

    Saito, Kazuya; Tsukahara, Akira; Okabe, Yoji

    2016-01-01

    Usually, origami-based morphing structures are designed on the premise of 'rigid folding', i.e. the facets and fold lines of origami can be replaced with rigid panels and ideal hinges, respectively. From a structural mechanics viewpoint, some rigid-foldable origami models are overconstrained and have negative degrees of freedom (d.f.). In these cases, the singularity in crease patterns guarantees their rigid foldability. This study presents a new method for designing self-deploying origami using the geometrically misaligned creases. In this method, some facets are replaced by 'holes' such that the systems become a 1-d.f. mechanism. These perforated origami models can be folded and unfolded similar to rigid-foldable (without misalignment) models because of their d.f. focusing on the removed facets, the holes will deform according to the motion of the frame of the remaining parts. In the proposed method, these holes are filled with elastic parts and store elastic energy for self-deployment. First, a new extended rigid-folding simulation technique is proposed to estimate the deformation of the holes. Next, the proposed method is applied on arbitrary-size quadrilateral mesh origami. Finally, by using the finite-element method, the authors conduct numerical simulations and confirm the deployment capabilities of the models.

  20. Preoperative biliary decompression preceding pancreaticoduodenectomy with plastic or self-expandable metallic stent.

    Science.gov (United States)

    Haapamäki, C; Seppänen, H; Udd, M; Juuti, A; Halttunen, J; Kiviluoto, T; Sirén, J; Mustonen, H; Kylänpää, L

    2015-06-01

    The rainage (PBD) prior to pancreaticoduodenectomy (PD) is controversial. If PBD is required, large bore self-expandable metallic stents (SEMS) are thought to maintain better drainage and have fewer postoperative complications than plastic stents. The confirming evidence is scarce. The aim of the study was to compare outcomes of surgery in patients who underwent PBD with SEMS or plastic stents deployed at endoscopic retrograde cholangiopancreatography (ERCP). This is a retrospective study of 366 patients having had PD during 2000-2009. Preceding endoscopic PBD was performed in 191 patients and nine had had percutaneous transhepatic drainage (PTD). At the time of operation, 163 patients had a plastic stent and 28 had SEMS. Due to stent exchanges, 176 plastic stents and 29 SEMS were placed in all. The stent failure rate was 7.4% for plastic stents and 3.4% for SEMS (p = 0.697). A bilirubin level under 50 µmol/L was reached by 80% of the patients with plastic stents and by 61% of the patients with SEMS (p = 0.058). A postoperative infection complication and/or a pancreatic fistula was found in 26% while using plastic stents and in 25% using SEMS (p = 1.000). In unstented patients with biliary obstruction, the bile juice was sterile significantly more often than in endoscopically stented patients (100% vs 1%, p stented and unstented patients were compared regarding postoperative infection complications, there was no significant difference between the groups (p = 0.365). Plastic stents did not differ from SEMS regarding the stent failure rate, bilirubin level decrease, amount of bacteria in the bile juice, or postoperative complications when used for PBD. The significantly higher price of SEMS suggests their use in selected cases only. © The Finnish Surgical Society 2014.

  1. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  2. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  3. Utility of the balloon-overtube-assisted modified over-the-wire stenting technique to treat post-sleeve gastrectomy complications.

    Science.gov (United States)

    Ponte, Ana; Pinho, Rolando; Proença, Luísa; Silva, Joana; Rodrigues, Jaime; Sousa, Mafalda; Silva, João Carlos; Carvalho, João

    2017-06-16

    To describe a modified technique of deployment of stents using the overtube developed for balloon-assisted enteroscopy in post-sleeve gastrectomy (SG) complications. Between January 2010 and December 2015, all patients submitted to an endoscopic stenting procedure to treat a post-SG stenosis or leakage were retrospectively collected. Procedures from patients in which the stent was deployed using the balloon-overtube-assisted modified over-the-wire (OTW) stenting technique were described. The technical success, corresponding to proper placement of the stent in the stomach resulting in exclusion of the SG leak or the stenosis, was evaluated. Complications related to stenting were also reported. Five procedures were included to treat 2 staple line leaks and 3 stenoses. Two types of stents were used, including a fully covered self-expandable metal stent designed for the SG anatomy (Hanarostent, ECBB-30-240-090; M.I. Tech, Co., Ltd, Seoul, South Korea) in 4 procedures and a biodegradable stent (BD stent 019-10A-25/20/25-080, SX-ELLA, Hradec Kralove, Czech Republic) in the remaining procedure. In all cases, an overtube was advanced with the endoscope through the SG to the duodenum. After placement of the guidewire and removal of the endoscope, the stent was easily advanced through the overtube. The overtube was pulled back and the stent was successfully deployed under fluoroscopic guidance. Technical success was achieved in all patients. The adoption of a modified technique of deployment of OTW stents using an overtube may represent an effective option in the approach of SG complications.

  4. Self-expanding stent-assisted middle cerebral artery recanalization: technical note

    International Nuclear Information System (INIS)

    Sauvageau, Eric; Levy, Elad I.

    2006-01-01

    Investigation into pharmacological and mechanical means of improving recanalization rates by intraarterial therapy has led to technological development. Angiographic recanalization has been associated with improvement in clinical outcome. A clot retriever has recently joined an imperfect armamentarium for intraarterial stroke therapy. In this report, we describe successful recanalization of an acute thrombotic occlusion of the inferior division of the middle cerebral artery (MCA) achieved with a self-expanding stent. An 82-year-old woman with a history of coronary atherosclerosis and previous cerebellar hemorrhage presented with a National Institutes of Health Stroke Scale (NIHSS) score of 11. Perfusion computed tomography imaging showed a left MCA territory deficit. Diffusion-weighted magnetic resonance (MR) imaging revealed a small punctiform insular hyperintensity. Angiography documented occlusion of the inferior division of the left MCA (Thrombolysis in Myocardial Infarction or Thrombolysis in Cerebral Infarction, TIMI/TICI, grade 0). Intraarterial delivery of eptifibatide to the occlusion site failed to recanalize the vessel. Deployment of a self-expanding stent in the occluded segment resulted in complete revascularization of the distal vascular bed. Angiography performed on the next day confirmed patency of the stented vessel segment (TIMI/TICI 3). The patient was discharged 3 days after the procedure (NIHSS 3). MR angiography obtained 3 months after the procedure documented left MCA patency. This technique may have a role worthy of further investigation in acute stroke therapy. (orig.)

  5. Efficacy of a Self-Expandable Porous Stent as the Sole Curative Treatment for Extracranial Carotid Pseudoaneurysms.

    Science.gov (United States)

    Chen, Peng Roc; Edwards, Nancy J; Sanzgiri, Aditya; Day, Arthur L

    2016-04-01

    Extracranial carotid pseudoaneurysms are uncommon vascular lesions. Even with conservative management complications can happen, such as delayed cerebral embolization or symptoms due to flow limitation. Although endovascular therapy can be curative, literature demonstrating a preferred technique is scant. Our goal was to evaluate the use of 1 technique only-the deployment of overlapping self-expandable porous stents-to treat a series of extracranial carotid pseudoaneurysms. From 2008 to 2014, 14 consecutive cases of symptomatic extracranial carotid pseudoaneurysms were managed with single or multilayer porous stents at our institution. Each patient underwent a standardized angiographic follow-up at 6 months. Twelve patients also received a follow-up computed tomography angiogram at 12 months, and yearly thereafter (median radiographic follow-up, 38 months). The total clinical follow-up period ranged between 6 and 69 months (median, 46 months). In our series, each of the extracranial carotid pseudoaneurysms appeared to be the result of carotid artery dissection with associated carotid stenosis at the origin of every pseudoaneurysm. Endovascular treatment consisted of 1-3 layers of self-expandable porous stents placed without balloon angioplasty. Immediately after stenting angiographic images were notable for stagnant opacification of the pseudoaneurysm through the stent(s). All pseudoaneurysms were completely obliterated by the 6-month follow-up angiogram and remained so throughout the radiographic follow-up period. Complications were minimal, consisting of 1 patient developing a mild Horner's syndrome after treatment that resolved during clinical follow-up. Extracranial carotid pseudoaneurysms can be successfully obliterated with the use of porous, self-expandable stents. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

    International Nuclear Information System (INIS)

    Higashiura, Wataru; Sakaguchi, Shoji; Morimoto, Kengo; Kichikawa, Kimihiko

    2008-01-01

    We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

  7. The treatment of complex airway diseases with inverted Y-shaped self-expandable metal stent

    International Nuclear Information System (INIS)

    Li Jianming; Jia Guangzhi

    2011-01-01

    Objective: To investigate the application and therapeutic effects of inverted Y-shaped self-expandable metal airway stent in treating complex airway diseases (stenosis or fistula). Methods: According to the distinctive anatomic structure and the pathological changes of complex airway stenosis or fistula, the inverted y-shaped self-expandable metal airway stent was designed. Under fluoroscopic monitoring, a total of 12 inverted Y-shaped self-expandable metal stents were implanted in 12 patients with complex airway diseases. Results: Stent placement in the trachea-bronchial tree was technically successful in all patients. After the operation, the symptom of dyspnea was immediately relieved and the bucking following food intake disappeared. The general physical condition and living quality were much improved in all patients. Conclusion: The use of inverted Y-shaped self-expandable metal airway stent for the management of complex airway stenosis involving the tracheal carina was a simple and safe procedure and it has satisfactory short-term clinical results. (authors)

  8. Self-made Palmaz stent: an experimental swine model study

    International Nuclear Information System (INIS)

    He Shicheng; Teng Gaojun; Guo Jinhe; Fang Wen

    2000-01-01

    Objective: To investigate the histologic changes and physicochemical stability of self-made Palmaz stent placed in swine arteries. Methods: The self-made Palmaz stent was made of 316L stainless steel wire. Nine stents were respectively placed within internal carotid, renal and iliac arteries of six pigs. Pigs were euthanized at intervals of 0.5, 1 and 3 months respectively and angiography were performed. Immediately followed by light and electro scanning microscopy for the stent zones. Results: All stents were successfully implanted in the target arteries and were patent shown in the angiographic examination immediately after the stent placement. Eight stents (8/9) remained patent at the time before euthanasia. No migration of stent were shown in the follow-up angiography. Light and electron scanning microscopy showed that the surface of the stents was covered by a thin layer of endothelial cells 2 weeks after the procedure and completely covered after 4 weeks. No inflammation occurred. Conclusions: The self-made Palmaz stent has good physicochemical stability and histocompatibility with easy placement, rather long term patency, histopathologic stability and thus the promising for clinical application

  9. Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks.

    Science.gov (United States)

    van Boeckel, Petra G A; Dua, Kulwinder S; Weusten, Bas L A M; Schmits, Ruben J H; Surapaneni, Naveen; Timmer, Robin; Vleggaar, Frank P; Siersema, Peter D

    2012-02-29

    Benign esophageal ruptures and anastomotic leaks are life-threatening conditions that are often treated surgically. Recently, placement of partially and fully covered metal or plastic stents has emerged as a minimally invasive treatment option. We aimed to determine the clinical effectiveness of covered stent placement for the treatment of esophageal ruptures and anastomotic leaks with special emphasis on different stent designs. Consecutive patients who underwent placement of a fully covered self-expandable metal stent (FSEMS), a partially covered SEMS (PSEMS) or a self-expanding plastic stent (SEPS) for a benign esophageal rupture or anastomotic leak after upper gastrointestinal surgery in the period 2007-2010 were included. Data on patient demographics, type of lesion, stent placement and removal, clinical success and complications were collected A total of 52 patients received 83 esophageal stents (61 PSEMS, 15 FSEMS, 7 SEPS) for an anastomotic leak (n=32), iatrogenic rupture (n=13), Boerhaave's syndrome (n=4) or other cause (n=3). Endoscopic stent removal was successful in all but eight patients treated with a PSEMS due to tissue ingrowth. Clinical success was achieved in 34 (76%, intention-to-treat: 65%) patients (PSEMS: 73%, FSEMS: 83%, SEPS: 83%) after a median of 1 (range 1-5) stent and a median stenting time of 39 (range 7-120) days. In total, 33 complications in 24 (46%) patients occurred (tissue in- or overgrowth (n=8), stent migration (n=10), ruptured stent cover (all Ultraflex; n=6), food obstruction (n=3), severe pain (n=2), esophageal rupture (n=2), hemorrhage (n=2)). One (2%) patient died of a stent-related cause. Covered stents placed for a period of 5-6 weeks may well be an alternative to surgery for treating benign esophageal ruptures or anastomotic leaks. As efficacy between PSEMS, FSEMS and SEPS is not different, stent choice should depend on expected risks of stent migration (SEPS and FSEMS) and tissue in- or overgrowth (PSEMS).

  10. Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective.

    Science.gov (United States)

    Bashar, Abul Hasan Muhammad; Kazui, Teruhisa; Washiyama, Naoki; Terada, Hitoshi; Yamashita, Katsushi; Haque, Mohammad E

    2003-08-01

    To comparatively assess the mechani-cal behavior of various clinically relevant Z-stent designs. A total of 16 Z-stents of original, biliary, spiral, and double-skirted designs (n=4 for each) were constructed using similar specifications for all. Stents were then evaluated for stiffness, snap opening force (SOF), flexibility, and displacement force using a novel tensiometer. Differences among the stents were determined using statistical methods. Stents explanted from dog aorta after a mean follow-up of 13 months were examined under a scanning electron microscope for surface defects. Forces required for about 50% reduction in diameter were 1.88 +/- 0.16 N, 3.81 +/- 0.21 N, 2.76 +/- 0.22 N, and 3.35 +/- 0.19 N for original, biliary, spiral, and skirted designs, respectively. Differences among the four designs were statistically significant at almost all points of measurement (P designs showed higher SOF values in the early measurements. Stents explanted from dog aorta after a mean duration of 13 months showed no obvious corrosion or breakage in the wire struts. Significant differences exist among the various Z-stent designs in terms of their mechanical properties. Understanding them should help to select the appropriate stent for a given lesion. 316L stainless steel shows a favorable long-term tissue interaction.

  11. Simulated training in colonoscopic stenting of colonic strictures: validation of a cadaver model.

    Science.gov (United States)

    Iordache, F; Bucobo, J C; Devlin, D; You, K; Bergamaschi, R

    2015-07-01

    There are currently no available simulation models for training in colonoscopic stent deployment. The aim of this study was to validate a cadaver model for simulation training in colonoscopy with stent deployment for colonic strictures. This was a prospective study enrolling surgeons at a single institution. Participants performed colonoscopic stenting on a cadaver model. Their performance was assessed by two independent observers. Measurements were performed for quantitative analysis (time to identify stenosis, time for deployment, accuracy) and a weighted score was devised for assessment. The Mann-Whitney U-test and Student's t-test were used for nonparametric and parametric data, respectively. Cohen's kappa coefficient was used for reliability. Twenty participants performed a colonoscopy with deployment of a self-expandable metallic stent in two cadavers (groups A and B) with 20 strictures overall. The median time was 206 s. The model was able to differentiate between experts and novices (P = 0. 013). The results showed a good consensus estimate of reliability, with kappa = 0.571 (P cadaver model described in this study has content, construct and concurrent validity for simulation training in colonoscopic deployment of self-expandable stents for colonic strictures. Further studies are needed to evaluate the predictive validity of this model in terms of skill transfer to clinical practice. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  12. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Park, Hyungkeun

    2006-01-01

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8±42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  13. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo [Asan Medical Center, Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea); Park, Hyungkeun [Asan Medical Center, Department of Urology, University of Ulsan College of Medicine, Seoul (Korea)

    2006-09-15

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8{+-}42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  14. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Pausawasadi, Nonthalee [Department of Medicine, Siriraj Hospital, Mahidol University, Bangkok (Thailand); Soontornmanokul, Tanassanee; Rerknimitr, Rungsun [Department of Medicine, Chulalongkorn University, Bangkok (Thailand)

    2012-02-15

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  15. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    International Nuclear Information System (INIS)

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee; Rerknimitr, Rungsun

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.

  16. Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

    Science.gov (United States)

    Pausawasadi, Nonthalee; Soontornmanokul, Tanassanee

    2012-01-01

    Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks. PMID:22563290

  17. Treatment of Portosystemic Shunt Myelopathy with a Stent Graft Deployed through a Transjugular Intrahepatic Route

    International Nuclear Information System (INIS)

    Jain, Deepak; Arora, Ankur; Deka, Pranjal; Mukund, Amar; Bhatnagar, Shorav; Jindal, Deepti; Kumar, Niteen; Pamecha, Viniyendra

    2013-01-01

    A case of surgically created splenorenal shunt complicated with shunt myelopathy was successfully managed by placement of a stent graft within the splenic vein to close the portosystemic shunt and alleviate myelopathy. To our knowledge, this is the first report of a case of shunt myelopathy in a patient with noncirrhotic portal fibrosis without cirrhosis treated by a novel technique wherein a transjugular intrahepatic route was adopted to deploy the stent graft

  18. Clinical feasibility of a new through-the-scope fully covered esophageal self-expandable metallic stent: an in vivo animal study.

    Science.gov (United States)

    Cheon, Young Koog; Lee, Tae Yoon; Sung, In Kyung; Shim, Chan Sup

    2014-01-01

    Most delivery devices used for esophageal stents for obstructing esophageal cancer have a diameter of 5-8 mm, a size that is too large to pass through the endoscopic working channel. The conventional esophageal stent requires multiple endoscopic procedures for implantation. The purpose of the present study was to evaluate the clinical feasibility of a newly developed fully covered, self-expanding, through-the-scope (TTS) esophageal stent in a porcine model. Eight mini pigs were used. Each animal underwent placement of a fully covered TTS stent (Hanarostent® Esophagus TTS) and the upper part of the stent was fixed by suturing with nylon. Fluoroscopy was carried out every week to assess migration of the stent. Follow-up endoscopy was done every month for 3 months to evaluate the status of the membrane, stent mesh, grade of tissue hyperplasia, and mucosal changes at both ends of the stent. All stents were successfully and easily deployed, and were placed without any distortion in the stent or without rupture of the membrane. In two cases, stent migration was observed after 8 weeks. No case of membrane disruption, stent mesh disruption or tissue hyperplasia at either end of the stent was found at the completion of the study. Our findings indicate that the new fully covered self-expanding TTS esophageal stent is easy and simple to implant, and no significant distortion of mesh or disruption of membrane was observed. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  19. Covered duodenal self-expandable metal stents prolong biliary stent patency in double stenting: The largest series of bilioduodenal obstruction.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Kondo, Hiromu; Yoshida, Michihiro; Shimizu, Shuya; Hirano, Atsuyuki; Okumura, Fumihiro; Ando, Tomoaki; Jinno, Naruomi; Takada, Hiroki; Togawa, Shozo; Joh, Takashi

    2018-03-01

    Endoscopic biliary and duodenal stenting (DS; double stenting) is widely accepted as a palliation therapy for malignant bilioduodenal obstruction. The aim of the current study was to investigate the patency and adverse events of duodenal and biliary stents in patients with DS. Patients who underwent DS from April 2004 to March 2017 were analyzed retrospectively with regard to clinical outcomes and predictive factors of recurrent biliary and duodenal obstruction (recurrent biliary obstruction [RBO] and recurrent duodenal obstruction [RDO]). A total of 109 consecutive patients was enrolled. Technical success of DS was achieved in 108 patients (99.1%). Symptoms due to biliary and duodenal obstruction were improved in 89 patients (81.7%). RBO occurred in 25 patients (22.9%) and RDO in 13 (11.9%). The median times to RBO and RDO from DS were 87 and 76 days, respectively. Placement of a duodenal uncovered self-expandable metal stent (U-SEMS) was significantly associated with RBO in the multivariable analysis (P = 0.007). Time to RBO was significantly longer in the duodenal covered self-expandable metal stent group than in the U-SEMS group (P = 0.003). No predictive factors of RDO were detected, and duodenal stent type was not associated with the time to RDO (P = 0.724). Double stenting was safe and effective for malignant bilioduodenal obstruction. Duodenal U-SEMS is a risk factor for RBO. The covered self-expandable metal stent is the preferred type of duodenal SEMS in patients with DS (Clinical trial registration number: UMIN000027606). © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  20. Nitinol Esophageal Stents: New Designs and Clinical Indications

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Boos, Irene; Vetter, Sylvia; Strohm, Michael; Domschke, Sigurd

    1996-01-01

    Purpose: To evaluate the clinical use of covered and noncovered, knitted nitinol stents in patients presenting new stent indications. Methods: Self-expandable, knitted nitinol stents were implanted in four patients for treatment of dysphagia. In two patients who had malignant strictures and had esophago-respiratory fistulae and in one patient with an esophagocutaneous fistula, polytetrafluoroethylene (PTFE)-covered stents were implanted. One patient received a noncovered stent, but a retrograde approach through a percutaneous endoscopic gastrostomy (PEG) fistula had to be chosen for recanalization of an esophageal occlusion. Two patients received stents for treatment of benign strictures. Results: Recanalization of the stricture and stent implantation were performed under fluoroscopic control without any procedure-related morbidity or mortality. Dysphagia improved in all patients and the esophageal fistulae could be sealed off by covered stents. During a maximum follow-up of 18 months, there was no stent migration or esophageal perforation. Complications observed were stent stenosis due to food impaction (1/4) and benign stent stenosis (2/2). Most complications could be treated by the interventional radiologist. Conclusion: Self-expandable, covered Nitinol stents provide an option for the treatment of dysphagia combined with esophageal fistulae. In combination with interventional radiology techniques, even complex strictures are accessible. For benign strictures, the value of stent treatment has not yet been proven

  1. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-10-01

    Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).

  2. Reversal of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-Induced Hepatic Encephalopathy Using a Strictured Self-Expanding Covered Stent

    International Nuclear Information System (INIS)

    Cox, Mitchell W.; Soltes, George D.; Lin, Peter H.; Bush, Ruth L.; Lumsden, Alan B.

    2003-01-01

    Hepatic encephalopathy is a known complication following percutaneous transjugular intrahepatic portosystemic shunt (TIPS) placement. We describe herein a simple and effective strategy of TIPS revision by creating an intraluminal stricture within a self-expanding covered stent, which is deployed in the portosystemic shunt to reduce the TIPS blood flow. This technique was successful in reversing a TIPS-induced hepatic encephalopathy in our patient

  3. [Cost-effectiveness trial of self-expandable metal stents and plastic biliary stents in malignant biliary obstruction].

    Science.gov (United States)

    Daróczi, Tímea; Bor, Renáta; Fábián, Anna; Szabó, Ella; Farkas, Klaudia; Bálint, Anita; Czakó, László; Rutka, Mariann; Szűcs, Mónika; Milassin, Ágnes; Molnár, Tamás; Szepes, Zoltán

    2016-02-14

    Self-expandable metal and plastic stents can be applied in the palliative endoscopic treatment of patients with unresectable malignant biliary obstruction. The use of metal stentsis recommended if the patient's life expectancy is more than four months. To compare the therapeutic efficacy and cost-effectiveness of metal and plastic stents in the treatment of malignant biliary obstruction. The authors retrospectively enrolled patients who received metal (37 patients) or plastic stent (37 patients). The complication rate, stent patency and cumulative cost of treatment were assessed in the two groups. The complication rate of metal stents was lower (37.84% vs. 56.76%), but the stent patency was higher compared with plastic stents (19.11 vs. 8.29 weeks; p = 0.0041). In the plastic stent group the frequency of hospitalization of patients in context with stent complications (1.18 vs. 2.32; p = 0.05) and the necessity of reintervention for stent dysfunction (17 vs. 27; p = 0.033) were substantially higher. In this group multiple stent implantation raised the stent patency from 7.68 to 10.75 weeks. There was no difference in the total cost of treatment of malignant biliary obstruction between the two groups (p = 0.848). Considering the cost of treatment and the burden of patients the authors recommend self-expandable metal sten timplantation if the life expectancy of patients is more than two months. In short survival cases multiple plastic stent implantation is recommended.

  4. Comparison of a New Polytetrafluoroethylene-Covered Metallic Stent to a Noncovered Stent in Canine Ureters

    International Nuclear Information System (INIS)

    Chung, Hwan-Hoon; Lee, Seung Hwa; Cho, Sung Bum; Park, Hong Suk; Kim, Young Sik; Kang, Byung Chul; Frisoli, Joan K.; Razavi, Mahmood K.

    2008-01-01

    The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first six dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted

  5. Impact of stent strut design in metallic stents and biodegradable scaffolds.

    Science.gov (United States)

    Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip

    2014-12-20

    Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Future developments in biliary stenting

    Directory of Open Access Journals (Sweden)

    Hair CD

    2013-06-01

    Full Text Available Clark D Hair,1 Divyesh V Sejpal21Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA; 2Department of Medicine, Section of Gastroenterology, Hofstra North Shore-LIJ School of Medicine, North Shore University Hospital, Manhasset, NY, USAAbstract: Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.Keywords: plastic stents, self-expandable metal stents, drug eluting stents, bioabsorbable stents, malignant biliary strictures, benign biliary strictures

  7. Future developments in biliary stenting

    Science.gov (United States)

    Hair, Clark D; Sejpal, Divyesh V

    2013-01-01

    Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting. PMID:23837001

  8. Stenting in the treatment of acute ischemic stroke: literature review.

    Directory of Open Access Journals (Sweden)

    Edgar A Samaniego

    2011-12-01

    Full Text Available Recanalization of acute large artery occlusions is a strong predictor of good outcome. The development of thrombectomy devices resulted in a significant improvement in recanalization rates compared to thrombolytics alone. However, clinical trials and registries with these thrombectomy devices in acute ischemic stroke (AIS have shown recanalization rates in the range of 40-81%. The last decade has seen the development of nickel titanium self-expandable stents (SES. These stents, in contrast to balloon-mounted stents, allow better navigability and deployment in tortuous vessels and therefore are optimal for the cerebral circulation. SES were initially used for stent-assisted coil embolization of intracranial aneurysms and for treatment of intracranial stenosis. However, a few authors have recently reported feasibility of deployment of SES in AIS. The use of these devices yielded higher recanalization rates compared to traditional thrombectomy devices. Encouraged by these results, retrievable SES systems have been recently used in AIS. These devices offer the advantage of resheathing and retrieving of the stent even after full deployment. Some of these stents can also be detached in case permanent stent placement is needed. Retrievable SES are being used in Europe and currently tested in clinical trials in the United States. We review the recent literature in the use of stents for the treatment of AIS secondary to large vessel occlusion.

  9. Esophagorespiratory fistula: treatment with self-expanding covered stent

    International Nuclear Information System (INIS)

    Zang Jian; Dou Yongchong; Wang Zheng; Kong Jian

    2002-01-01

    Objective: To evaluate self-expanding covered stent in the management of esophagorespiratory fistula. Methods: A self-expanding esophageal covered stent was implanted under fluoroscopic guidance in 13 patients with esophagorespiratory fistula. In this series patients aged 31-73 years (60.2 years in average). All patients had a pre-procedure fast of 6-41 days (17.3 days in average), in which 12 patients had pulmonary infection. Results: All fistulas were excluded and swallowing function was restored. No stend-related complication was observed. Pulmonary infection was managed in 10 patients out of 13. The mean survived time was 33.3 wks (1-178 wks) in follow-up. Conclusion: Covered self-expanding stent implantation is a safe and effective treatment of ERF

  10. Complication after self expandable metallic stent for esophageal cancer

    International Nuclear Information System (INIS)

    Nagahama, Takeshi; Maruyama, Michio; Kato, Kiyomi; Shinoura, Hiroshi; Hasegawa, Kumi; Takashima, Itaru; Ebuchi, Masakazu

    2003-01-01

    Major complications after placement of esophageal stent and airway stent were reviewed and evaluated. Four patients, including two patients with perforations and two patients with fistula formation, developed major complications after placement of a self expandable metallic stent. Two patients underwent additional radiation to improve stricture after stent placement. In one patient, stent placement was selected to improve esophageal stricture that occurred after radical radiation therapy. In one patient, migration of stent into the lesion caused a perforation. It can be concluded that additional radiation after stent placement increases the risk of complication. Stent migration also can lead to the risk of perforation. (author)

  11. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.

    Science.gov (United States)

    van Halsema, Emo E; Wong Kee Song, Louis M; Baron, Todd H; Siersema, Peter D; Vleggaar, Frank P; Ginsberg, Gregory G; Shah, Pari M; Fleischer, David E; Ratuapli, Shiva K; Fockens, Paul; Dijkgraaf, Marcel G W; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six tertiary care centers in the United States and Europe. A total of 214 patients with benign esophageal diseases undergoing endoscopic stent removal. Endoscopic stent removal. Endoscopic techniques for stent removal, time to stent removal, and adverse events related to stent removal. A total of 214 patients underwent a total of 329 stent extractions. Stents were mainly placed for refractory strictures (49.2%) and fistulae (49.8%). Of the removed stents, 52% were fully covered self-expandable metal stents (FCSEMSs), 28.6% were partially covered self-expandable metal stents (PCSEMSs), and 19.5% were self-expandable plastic stents. A total of 35 (10.6%) procedure-related adverse events were reported, including 7 (2.1%) major adverse events. Multivariate analysis revealed that use of PCSEMSs (P stent removal. Favorable factors for successful stent removal were FCSEMSs (P ≤ .012) and stent migration (P = .010). No significant associations were found for stent indwelling time (P = .145) and stent embedding (P = .194). Retrospective analysis, only tertiary care centers. With an acceptable major adverse event rate of 2.1%, esophageal stent removal in the setting of benign disease was found to be a safe and feasible procedure. FCSEMSs were more successfully removed than self-expandable plastic stents and PCSEMSs. Adverse events caused by stent removal were not time dependent. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. Endoscopic bilateral stent-in-stent placement for malignant hilar obstruction using a large cell type stent.

    Science.gov (United States)

    Park, Jin Myung; Lee, Sang Hyub; Chung, Kwang Hyun; Jang, Dong Kee; Ryu, Ji Kon; Kim, Yong-Tae; Lee, Jae Min; Paik, Woo Hyun

    2016-12-01

    Bilateral stent-in-stent (SIS) self-expandable metal stent placement is technically challenging for palliation of unresectable malignant hilar obstruction. In the SIS technique, the uniform large cell type biliary stent facilitates contralateral stent deployment through the mesh of the first metallic stent. This study aimed to assess the technical success and clinical effectiveness of this technique with a uniform large cell type biliary stent. Thirty-one patients who underwent bilateral SIS placement using a large cell type stent were reviewed retrospectively. All patients showed malignant hilar obstruction (Bismuth types II, III, IV) with different etiologies. Sixteen (51.6%) patients were male. The mean age of the patients was 67.0+/-14.0 years. Most patients were diagnosed as having hilar cholangiocarcinoma (58.1%) and gallbladder cancer (29.0%). Technical success rate was 83.9%. Success was achieved more frequently in patients without masses obstructing the biliary confluence (MOC) than those with MOC (95.2% vs 60.0%, P=0.03). Functional success rate was 77.4%. Complications occurred in 29.0% of the patients. These tended to occur more frequently in patients with MOC (50.0% vs 19.0%, P=0.11). Median time to recurrent biliary obstruction was 188 days and median survival was 175 days. The large cell type stent can be used efficiently for bilateral SIS placement in malignant hilar obstruction. However, the risk of technical failure increases in patients with MOC, and caution is needed to prevent complications for these patients.

  13. Initial and mid-term results of a 4F compatible self-expanding low strut profile nitinol stent in the superficial femoral artery

    International Nuclear Information System (INIS)

    Muehlenbruch, G.; Brock, H.; Das, M.; Hohl, C.; Mahnken, A.H.; Wildberger, J.; Guenther, R.W.; Haage, P.

    2007-01-01

    Purpose: To evaluate the initial and mid-term results of a new self-expanding low strut profile nitinol stent for treatment of atherosclerotic lesions stenoses and occlusions in the superficial femoral artery (SFA). Materials and Methods: In 8 patients (4 male, 4 female, mean age 74.8 ± 8.8 years) with SFA lesions and non-satisfying results after PTA treatment alone, 10 self-expanding nitinol Xpert stents were deployed via a 4 F sheath. Stent characteristics and handling were graded by the interventionalist. Fontaine classification, duplex flow measurements and ankle brachial index (ABI) at rest and stress were taken prior and one day after stent placement. Patients were followed 3, 6 and 12 months after the procedure obtaining the same parameters at each appointment. Results: Initial stent treatment was successful in all patients. Stent handling and positioning were rated very good and safe. All patients improved clinically by at least one Fontaine stage (range before treatment: stage IIb to IV). The mean ABI at rest (stress) improved initially from 0.68 (0.70) to 1.07 (0.99). During a mean follow-up period of 8.3 months no case of clinically relevant in-stent stenosis was observed with stable values of ABI at rest and stress. (orig.)

  14. Efficacy and safety of a new fully covered self-expandable non-foreshortening metal esophageal stent.

    Science.gov (United States)

    Dua, Kulwinder S; Latif, Sahibzada U; Yang, Juliana F; Fang, Tom C; Khan, Abdul; Oh, Young

    2014-10-01

    Fully covered esophageal self-expandable metal stents (SEMSs) are potentially removable but can be associated with high migration rates. For precise positioning, non-foreshortening SEMSs are preferred. Recently, a new fully covered non-foreshortening SEMS with anti-migration features was introduced. To evaluate the efficacy and safety of this new esophageal SEMS. Retrospective study. Single, tertiary-care center. Consecutive patients with malignant and benign strictures with dysphagia grade of ≥3 and patients with fistulas/leaks were studied. Stent placement and removal. Technical success in stent deployment/removal, efficacy in relieving dysphagia and sealing fistulas/leaks, and adverse events. Forty-three stents were placed in 35 patients (mean [± standard deviation] age 65 ± 11 years; 31 male), 24 for malignant and 11 for benign (5 strictures, 6 leaks) indications. Technical success in precise SEMS placement was 100%. The after-stent dysphagia grade improved significantly (at 1 week: 1.5 ± 0.7; at 4 weeks: 1.2 ± 0.4; baseline: 3.8 ± 0.4; P stents were removed for clinical indications, with technical success of 100%. All leaks sealed after SEMS placement and did not recur after stent removal. All benign strictures recurred after stent removal. Adverse events included migration (14%), chest pain (11%), and dysphagia from tissue hyperplasia (6%). There was no stent-related mortality. Nonrandomized, single-center study. The new esophageal SEMS was effective in relieving malignant dysphagia, allowed for precise placement, and was easily removable. It was effective in treating benign esophageal fistulas and leaks. Stent-related adverse events were acceptable. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  15. Treatment of Benign Tracheal Stenosis Utilizing Self-Expanding Nitinol Stents

    International Nuclear Information System (INIS)

    Sesterhenn, Andreas M.; Wagner, Hans-Joachim; Alfke, Heiko; Werner, Jochen A.; Lippert, Burkard M.

    2004-01-01

    We assessed the results of self-expanding metallic stent insertion into benign proximal tracheal stenosis in patients not appropriate or unfit for surgical repair. Proximal benign tracheal stenoses had occurred in 11 patients (7 men, 4 women, mean age 68.8 years) after long-time intubation (n = 6), tracheostomy (n = 4), or chondropathia (n = 1). Fourteen self-expanding nitinol stents were placed in the patients under general anesthesia with endoscopical and fluoroscopical guidance. Stent insertion was successful in all cases and led to immediate relief of the morphological and functional airway obstruction. No immediate complications were noted. During the mean follow-up period of 67.5 weeks we observed one recurrent dyspnea 3 months after implantation and granuloma formation at the stent insertion site in another patient. Both complications were successfully treated with additional stent insertion in one case and laser resection of granulomas in the other. Self-expanding nitinol stents should be considered for the treatment of benign proximal tracheal obstruction in selected patients for whom surgical repair is contraindicated

  16. Wing-shaped plastic stents vs. self-expandable metal stents for palliative drainage of malignant distal biliary obstruction: a randomized multicenter study.

    Science.gov (United States)

    Schmidt, Arthur; Riecken, Bettina; Rische, Susanne; Klinger, Christoph; Jakobs, Ralf; Bechtler, Matthias; Kähler, Georg; Dormann, Arno; Caca, Karel

    2015-05-01

    Previous studies have shown superior patency rates for self-expandable metal stents (SEMS) compared with plastic stents in patients with malignant biliary obstruction. The aim of this study was to compare stent patency, patient survival, and complication rates between a newly designed, wing-shaped, plastic stent and SEMSs in patients with unresectable, malignant, distal, biliary obstruction. A randomized, multicenter trial was conducted at four tertiary care centers in Germany. A total of 37 patients underwent randomization between March 2010 and January 2013. Patients underwent endoscopic retrograde cholangiography with insertion of either a wing-shaped, plastic stent without lumen or an SEMS.  Stent failure occurred in 10/16 patients (62.5 %) in the winged-stent group vs. 4/18 patients (22.2 %) in the SEMS group (P = 0.034). The median time to stent failure was 51 days (range 2 - 92 days) for the winged stent and 80 days (range 28 - 266 days) for the SEMS (P = 0.002). Early stent failure (stent failure was significantly higher in the winged-stent group compared with the SEMS group. A high incidence of early stent failure within 8 weeks was observed in the winged-stent group. Thus, the winged, plastic stent without central lumen may not be appropriate for mid or long term drainage of malignant biliary obstruction. Study registration ClinicalTrials.gov (NCT01063634). © Georg Thieme Verlag KG Stuttgart · New York.

  17. Development and modeling of self-deployable structures

    Science.gov (United States)

    Neogi, Depankar

    Deployable space structures are prefabricated structures which can be transformed from a closed, compact configuration to a predetermined expanded form in which they are stable and can bear loads. The present research effort investigates a new family of deployable structures, called the Self-Deployable Structures (SDS). Unlike other deployable structures, which have rigid members, the SDS members are flexible while the connecting joints are rigid. The joints store the predefined geometry of the deployed structure in the collapsed state. The SDS is stress-free in both deployed and collapsed configurations and results in a self-standing structure which acquires its structural properties after a chemical reaction. Reliability of deployment is one of the most important features of the SDS, since it does not rely on mechanisms that can lock during deployment. The unit building block of these structures is the self-deployable structural element (SDSE). Several SDSE members can be linked to generate a complex building block such as a triangular or a tetrahedral structure. Different SDSE and SDS concepts are investigated in the research work, and the performance of SDS's are experimentally and theoretically explored. Triangular and tetrahedral prototype SDS have been developed and presented. Theoretical efforts include modeling the behavior of 2-dimensional SDSs. Using this design tool, engineers can study the effects of different packing configurations and deployment sequence; and perform optimization on the collapsed state of a structure with different external constraints. The model also predicts if any lockup or entanglement occurs during deployment.

  18. Malignant biliary obstruction: percutaneous use of self-expandable stents

    NARCIS (Netherlands)

    Laméris, J. S.; Stoker, J.; Nijs, H. G.; Zonderland, H. M.; Terpstra, O. T.; van Blankenstein, M.; Schütte, H. E.

    1991-01-01

    A total of 83 self-expandable metallic stents were placed percutaneously in 69 patients for palliation of malignant biliary obstruction. Stent diameter was 1 cm; length, 3.5-10.5 cm. Of the 41 patients with common bile duct obstruction, 27 died 0.2-12 months (median, 3.2 months) after stent

  19. A Novel Self-Expandable, Radioactive Airway Stent Loaded with 125I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog.

    Science.gov (United States)

    Wang, Yong; Guo, Jin-He; Zhu, Guang-Yu; Zhu, Hai-Dong; Chen, Li; Lu, Jian; Wang, Chao; Teng, Gao-Jun

    2017-07-01

    Airway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with 125 I seeds in healthy beagle dog. Under fluoroscopic guidance, forty-eight self-expandable airway stents loaded with 125 I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting. All stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of 125 I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope. This study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with 125 I seeds in healthy beagle dog.

  20. Management of benign biliary strictures with a novel retrievable self-expandable metal stent.

    Science.gov (United States)

    Hu, Bing; Leung, Joseph W; Gao, Dao Jian; Wang, Tian Tian; Wu, Jun

    2014-03-01

    Endoscopic placement of covered self-expandable metal stent (SEMS) has gained popularity in the management of benign biliary strictures (BBS). The existing SEMS has been designed primarily to palliate malignant biliary obstruction and has a high frequency of stent migration, difficulty in retrieval and stricture recurrence after stent removal. This study aimed to design a novel retrievable SEMS dedicated to the treatment of extrahepatic BBS and evaluate its clinical efficacy and safety. A short fully covered SEMS (FCSEMS) with a retrieval lasso was designed for the specific treatment of BBS. A total of 45 patients with segmental extrahepatic BBS were included in this study. The stent was placed entirely inside the bile duct with only the retrieval lasso extending from the papilla. The stents were recommended to be in situ for 6 to 12 months before removal. The FCSEMS was successfully placed in all 45 patients. In all, 33 patients had their FCSEMS successfully removed after a mean period of 8.6 ± 3.7 (range 2-15.5) months. Stent migration occurred in 9.1% of the patients. During a mean follow-up of 18.9 months after stent removal, recurrent stricture was found in 2 (6.1%) patients and was successfully treated with a second FCSEMS. Overall, the strictures resolved in 30/33 (90.9%) patients. Intraductal placement of a short FCSEMS is suitable for the treatment of segmental extrahepatic BBS. This new removable design offered prolonged stenting and drainage for BBS for up to one year with minimal complications. © 2013 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  1. New treatment of iliac artery disease: focus on the Absolute Pro® Vascular Self-Expanding Stent System

    Directory of Open Access Journals (Sweden)

    Gates L

    2013-09-01

    Full Text Available Lindsay Gates, Jeffrey Indes Vascular and Endovascular Surgery, Yale University School of Medicine, New Haven, CT, USA Abstract: Management of iliac artery disease has evolved over the years, from a surgical-only approach to a primarily endovascular-only approach as the first line treatment option. This has been continuously improved upon with the advent of new devices and applied technologies. Most recently in particular, the literature has shown good, reliable outcomes with the use of self-expandable stents in iliac artery atherosclerotic lesions. Nevertheless, no device is without its limitations, and the Absolute Pro® Vascular Self-Expanding Stent System was designed with the intent of overcoming some of the shortcomings of other available stents while maintaining acceptable postprocedural outcomes. Based on preliminary industry-acquired data, it has achieved these goals and appears to be an emergent competitor for the treatment of both focal and complex iliac artery lesions. Keywords: Absolute-Pro®, iliac stent, self-expanding stents, atherosclerotic disease

  2. Study of the Behavior of a Bell-Shaped Colonic Self-Expandable NiTi Stent under Peristaltic Movements

    Directory of Open Access Journals (Sweden)

    Sergio Puértolas

    2013-01-01

    Full Text Available Managing bowel obstruction produced by colon cancer requires an emergency intervention to patients usually in poor conditions, and it requires creating an intestinal stoma in most cases. Regardless of that the tumor may be resectable, a two-stage surgery is mandatory. To avoid these disadvantages, endoscopic placement of self-expanding stents has been introduced more than 10 years ago, as an alternative to relieve colonic obstruction. It can be used as a bridge to elective single-stage surgery avoiding a stoma or as a definitive palliative solution in patients with irresectable tumor or poor estimated survival. Stents must be capable of exerting an adequate radial pressure on the stenosed wall, keeping in mind that stent must not move or be crushed, guaranteeing an adequate lumen when affected by peristaltic waves. A finite element simulation of bell-shaped nitinol stent functionality has been done. Catheter introduction, releasing at position, and the effect of peristaltic wave were simulated. To check the reliability of the simulation, a clinical experimentation with porcine specimens was carried out. The stent presented a good deployment and flexibility. Stent behavior was excellent, expanding from the very narrow lumen corresponding to the maximum peristaltic pressure to the complete recovery of operative lumen when the pressure disappears.

  3. Endoscopic removal of malfunctioning biliary self-expandable metallic stents.

    Science.gov (United States)

    Familiari, Pietro; Bulajic, Milutin; Mutignani, Massimiliano; Lee, Linda S; Spera, Gianluca; Spada, Cristiano; Tringali, Andrea; Costamagna, Guido

    2005-12-01

    Endoscopic removal of malfunctioning self-expandable metallic biliary stents (SEMS) is difficult and not well described. The aim of this study is to review the indications, the techniques, and the results of SEMS removal in a cohort of patients with malfunctioning stents. All patients who underwent an attempt at endoscopic removal of biliary SEMS over a 5-year period were retrospectively identified. The main indications for SEMS removal were the following: distal migration of the stent or impaction to the duodenum, impaction into the bile-duct wall, tissue ingrowth, and inappropriate length of the stent causing occlusion of intrahepatic ducts. SEMS were removed by using foreign-body forceps or polypectomy snares. Endoscopic removal of 39 SEMS (13 uncovered and 26 covered) was attempted in 29 patients (17 men; mean age, 66 years). SEMS extraction was attempted after a mean of 7.5 months (8.75 months standard deviation) post-SEMS insertion. Removal was successful in 20 patients (68.9%) and in 29 SEMS (74.3%). Covered SEMS were effectively removed more frequently than uncovered ones: 24 of 26 (92.3%) and 5 of 13 (38.4%), respectively (p < 0.05). No major complications were recorded. Multivariate analysis showed that the time interval between insertion and removal, SEMS length, stent-mesh design (zigzag vs. interlaced), and indication for removal were not predictive of success at stent removal. Endoscopic removal of biliary SEMS is feasible and safe in more than 70% of cases. Because only 38% of uncovered SEMS were removable, the presence of a stent covering is the only factor predictive of successful stent extraction. The presence of diffuse and severe ingrowth was the main feature limiting SEMS removal.

  4. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    Science.gov (United States)

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p stent use for palliation (78.6% vs 56.3%; p stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes of self-expandable metal stent placement and must be considered by endoscopists. See Video Abstract at http

  5. Design aspects of a deployable tensegrity-hollow-rope footbridge

    OpenAIRE

    Rhode-Barbarigos , Landolf; Bel Hadj Ali , Nizar; Motro , René; Smith , Ian F.C.

    2012-01-01

    International audience; Tensegrity structures are composed of cables and struts in a pre-stressed self-equilibrium. Although tensegrity first appeared in the 1950s, it is seldom used in civil engineering. This paper focuses on the design aspects of a deployable tensegrity-hollow-rope footbridge. Deployment is usually not a critical design case for traditional deployable structures. However, for tensegrity systems deployment may be critical due to the actuation required. In this paper, deploym...

  6. Implantation of modified Y-shaped self-expandable stent for the treatment of stenosis of gastroenteric stoma: preliminary results in five cases

    International Nuclear Information System (INIS)

    Wu Gang; Si Jiangtao; Han Xinwei; Jiao Dechao; Ding Pengxu; Fu Mingti; Li Zhen; Ma Ji

    2010-01-01

    Objective To investigate the feasibility and therapeutic effect of stenting therapy by using modified Y-shaped self-expandable metal stent for the stenosis of gastroenteric stoma. Methods: According to the particular anatomic structures and the pathological features of the narrowed gastroenteric stoma,the authors designed a modified Y-shaped self-expandable metal stent. Under the fluoroscopic guidance, implantation of modified Y-shaped self-expandable metal stent was performed in 5 patients with narrowed gastroenteric stoma. The technical safety and the clinical results were evaluated. Results: The modified Y-shaped self-expandable metal stent was successfully implanted with one procedure in all five patients. After the implantation the symptoms such as nausea, vomiting, abdominal distension were promptly relieved, and the patients' living quality was markedly improved. Conclusion: The stenting therapy with modified Y-shaped self-expandable metal stent can rapidly relieve the stenosis of gastroenteric stoma once for all. The technique is feasible and the short-term effect is reliable, therefore, it is worth popularizing this therapy in clinical practice. (authors)

  7. Evaluation of anti-migration properties of biliary covered self-expandable metal stents.

    Science.gov (United States)

    Minaga, Kosuke; Kitano, Masayuki; Imai, Hajime; Harwani, Yogesh; Yamao, Kentaro; Kamata, Ken; Miyata, Takeshi; Omoto, Shunsuke; Kadosaka, Kumpei; Sakurai, Toshiharu; Nishida, Naoshi; Kudo, Masatoshi

    2016-08-14

    To assess anti-migration potential of six biliary covered self-expandable metal stents (C-SEMSs) by using a newly designed phantom model. In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration (RFM) was measured by a force gauge on the stent end. Radial force (RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare (ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model. Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables (ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state. RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration.

  8. Mechanical Thrombectomy using a solitaire stent in acute ischemic stroke; The relationship between the visible antegrade flow on first device deployment and final success in revascularization

    International Nuclear Information System (INIS)

    Lee, Sung Ho; Lee, Byung Hon; Hwang, Yoon Joon; Kim, Su Young; Lee, Ji Young; Hong, Keun Sik; Cho, Yong Jin

    2015-01-01

    The purpose of the study was to evaluate the relationship between the successful revascularization on the first Solitaire stent deployment and the successful revascularization on the final angiography in acute ischemic stroke. From February 2012 to April 2014, 24 patients who underwent Solitaire stent thrombectomy as the first thrombectomy method for treatment of acute ischemic strokes were retrospectively reviewed. When the first Solitaire stent was deployed, 9 patients showed revascularization (Group 1) and 15 patients did not show revascularization (Group 2). Revascularization immediately after the first Solitaire stent removal and on the final angiography were comparatively assessed between the 2 groups. Statistical analysis was performed by the Fisher exact test and Student's t-test. The rates of revascularization maintenance immediately after the first Solitaire stent removal were 89% in Group 1 and 27% in Group 2, respectively (p = 0.009), and the rates of final successful revascularization were 100% in Group 1 and 47% in Group 2, respectively (p = 0.009). There was a statistically significant difference between the 2 groups. Revascularization on the first Solitaire stent deployment can be a useful predictor in evaluating the success of final revascularization in the treatment of acute ischemic stroke.

  9. Predictors of Long-Term Results After Treatment of Iliac Artery Obliteration by Transluminal Angioplasty and Stent Deployment

    International Nuclear Information System (INIS)

    Funovics, M.A.; Lackner, B.; Cejna, M.; Peloschek, P.; Sailer, J.; Philipp, M.O.; Maca, T.; Ahmadi, A.; Minar, E.; Lammer, J.

    2002-01-01

    Purpose: To investigate initial and long-term success rate after percutaneous treatment of iliac artery occlusion with angioplasty and stent deployment. To investigate the influence of vascular comorbidity, lesion length, stent placement and lesion coverage as possible predictors of outcome. Methods: Between January 1994 and December 1999, 80 iliac recanalizations were performed on 78 patients, median age 61.1 ±11.5 (SD) years. All patients were followed up by clinical examinations, duplex ultrasound and intravenous digital subtraction angiography. Mean follow-up time was 2.0 ± 1.53 (SD) years.Multivariate Cox regression analysis was used to determine the influence of cofactors on patency. Results: One, 2 and 4 years after recanalization, primary patency was 78.1%, 74.5% and 64.0%; secondary patency was 88.8%, 88.8% and 77.9%, respectively.Patients with shorter occlusions, complete lesion coverage and patent ipsilateral femoral arteries had significantly longer patency rates.Complications included inguinal hematoma (n=1), technical failure (n=3) aortic dissection (n=1), embolic occlusions (n=7), gluteal claudication (n=1) and genital necrosis after subsequent urethral surgery in one patient with contralateral occlusion and ipsilateral overstenting of the internal iliac artery with subsequent stenosis. Complications were of permanent clinical significance in seven of 78 (9%) of the patients. In 17 (22%) cases, percutaneous reintervention was performed with angioplasty in the stent (n=16) or deployment of a new stent (n=1). Conclusion: Endoluminal stent placement has its place in an interdisciplinary therapeutic approach as a viable therapeutic alternative to major transabdominal bypass surgery and can be performed with comparable complication rates. Patients with short occlusions, patent femoral arteries, and stents covering the entire occlusion have significant longer patency

  10. Self-made metal stent in treatment of nasolacrimal duct obstruction

    International Nuclear Information System (INIS)

    Du Wei; Pang Ruilin; Luo Gang; Gu Jingchuan; Gong Yongxiang

    2003-01-01

    Objective: To evaluate application of self-made metal stent in treatment of nasolacrimal duct obstruction. Methods: In total 15 cases, self-made metal stents made of stainless steel wire were implanted in 18 obstructed nasolacrimal ducts. The lacrimal passages were rinsed and re-canalized followed by antegrade inserting the guide wire from upper dacryon. A dilator was inserted over the guide wire, and then a stent was released from a sheath into the impaired section of nasolacrimal duct. Dacryocystography was performed before and after the interventional procedure. Results: Dacryocystography showed patent nasolacrimal duct after treatment. Epiphora disappeared completely in 11 cases (13 ducts), improved in 4 cases (5 ducts). These cases had been followed up for 61-219 days (167 days in average). Relapse was found in 2 cases (2 ducts) in three months. Those 2 stents were removed by surgical procedure and found occluded by granulation. Conclusion: Interventional placement of the self-made metal stent is a simple, safe, low-cost and effective treatment of the nasolacrimal duct obstruction

  11. Results of the new nitinol self-expandable stents for distal biliary structures

    NARCIS (Netherlands)

    Smits, M.; Huibregtse, K.; Tytgat, G.

    1995-01-01

    The nitinol stent is a self-expandable spiral stent made of nickel-titanium alloy. We performed a pilot study to evaluate the method of stent insertion and stent efficacy. Twenty-eight patients with irresectable malignancy had nitinol stents inserted for obstructive jaundice due to distal biliary

  12. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    International Nuclear Information System (INIS)

    Youn, Sung Won; Kim, Ho Kyun; Do, Jin Kook; Kim, Young Whan

    2011-01-01

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  13. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Dept. of Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Do, Jin Kook [Dept. of Neurology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Whan [Dept. of Radiology, University College of Medicine, Daegu (Korea, Republic of)

    2011-12-15

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  14. Differences in Endothelial Injury After Balloon Angioplasty, Insertion of Balloon-Expanded Stents or Release of Self-Expanding Stents: An Electron Microscopic Experimental Study

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Carlemalm, Erik; Cwikiel, Wojciech

    1999-01-01

    Purpose: To evaluate which of six different commonly available stents inserted into an artery without percutaneous transluminal angioplasty (PTA) causes the least endothelial damage. To compare the degree of endothelial injury after insertion of such a stent with injury caused by PTA. Methods: Twelve healthy pigs were used in the experiments. In the first part of the study six different types of stents were inserted into the common iliac arteries. In the second part of the study self-expanding stents with large spaces between the wires were used. PTA was performed in the contralateral iliac artery. The pigs were killed immediately after the procedure and resected specimens examined after fixation, using scanning electron microscopy. Results: All procedures but two were accomplished successfully. More endothelium was preserved after insertion of self-expanding stents with large spaces between the wires, compared with stents with small spaces and balloon-expanded stents. After insertion of self-expanding stents with large spaces, 50.1% ± 16.4% of the endothelium remained intact, compared with only 5.6% ± 7.7% after PTA. The difference was statistically significant (p < 0.001). Conclusion: Self-expanding stents with large spaces between the wires, inserted without PTA, cause less damage to the endothelium than other stents and significantly less damage than PTA

  15. Esophagojejunal anastomotic leak managed with self expandable metallic stent

    Directory of Open Access Journals (Sweden)

    Arvind Madurandagam Annapillai

    2013-01-01

    Full Text Available Esophagealjejunal anastomotic leak after gastrectomy is a serious surgical emergency with high mortality. This report describes a 57-year-old male with esophagojejunal anastomotic leak following total gastrectomy for gastric cancer and was managed successfully with self-expandable metallic stent. To our knowledge this is the first such report from India. This case report highlights the need of interdisciplinary coordination in managing this difficult clinical situation. Endotherapy with self-expandable metallic stent (SEM provided twin benefits of improving respiratory embarrassment and the joy of eating. Therapy of such difficult cases must be individualized; however, and SEM stent usage is a viable option

  16. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  17. In Vitro Comparison of Self-Expanding Versus Balloon-Expandable Stents in a Human Ex Vivo Model

    International Nuclear Information System (INIS)

    Grenacher, Lars; Rohde, Stefan; Gaenger, Ellen; Deutsch, Jochen; Kauffmann, Guenter W.; Richter, Goetz M.

    2006-01-01

    The objective was to compare the radial strength and expansile precision of self-expanding stents and balloon-expandable stents in a human cadaver bifurcation model. Seven different self-expanding (LUMINEXX, JOSTENT SelfX, JOSTENT SelfX hrf, Sinus-Repo, Sinus SuperFlex, Easy Wallstent, SMART) and four different balloon-expandable stent models (Palmaz, Sinus Stent, SAXX Medium, JOSTENT peripheral), each type 10 stents (total n = 110 stents) were implanted into the common iliac arteries of human cadaver corpses. The maximum stent diameter was 10 mm for all models. After stent implantation, the specimens were filled with silicone caoutchouc. After 24 h, the vascular walls including the stents were removed from the hardened casts. Diameters were taken and the weight of the cast cylinders was measured in air and in purified water to calculate the volume of the bodies (according to Archimedes Law) as a relative but precise degree for the radial strength of the implanted stents. The cylindrical casts of the self-expanding stents showed lower mean diameters (8.2 ± 1.0 mm) and mean volumes (0.60 ± 0.14 ml/cm) than in the balloon-expandable stent group (10.1 ± 0.3 mm and 0.71 ± 0.04 ml/cm, respectively; p < 0.01). The nominal maximum diameter of 10 mm was not achieved in any of the self-expanding stents, but this was achieved in more than 70% (29/40) of the balloon-expandable stent specimens (p < 0.05). The variation between achieved volumes was significantly larger in self-expanding (range: 0.23-0.78 ml/cm) than in balloon-expandable stents (range: 0.66-0.81 ml/cm; p < 0.05). Self-expanding stents presented considerably lower radial expansion force and lower degree of precision than balloon-expandable stents

  18. Self-expandable metallic stents vs. plastic stents for endoscopic biliary drainage in hepatocellular carcinoma.

    Science.gov (United States)

    Chung, Kwang Hyun; Lee, Sang Hyub; Park, Jin Myung; Lee, Jae Min; Ahn, Dong-Won; Ryu, Ji Kon; Kim, Yong-Tae

    2015-06-01

    The patency of self-expandable metallic stents (SEMS) is known to be better than plastic stents in the palliation of malignant biliary obstruction. However, data are scarce for obstructive jaundice caused by hepatocellular carcinoma (HCC). This study aimed to compare SEMSs and plastic stents for the palliation of obstructive jaundice in unresectable HCC. A total of 96 patients who underwent endoscopic retrograde biliary drainage with SEMSs or plastic stents were included in this retrospective analysis. The rate of successful biliary drainage, adverse events, stent patency duration, and patient survival were compared between the SEMS (n = 36) and plastic stent (n = 60) groups. The rate of successful biliary drainage was similar between the SEMS and plastic stent groups (25/36 [69.4 %] vs. 39/60 [65.0 %]; P = 0.655). Adverse events occurred in 6 patients (16.7 %) in the SEMS group and 13 patients (21.7 %) in the plastic stent group (P = 0.552). The median patency duration was also similar between the two groups (60 vs. 68 days; P = 0.396). The median patient survival was longer in the plastic stent group than in the SEMS group (123 vs. 48 days; P = 0.005). SEMSs were not superior to plastic stents for the palliation of malignant biliary obstruction in HCC with regard to successful drainage, stent patency, and adverse events. Patient survival was better in the plastic stent group. Given the lower cost, plastic stents could be a favorable option for malignant biliary obstruction caused by HCC. © Georg Thieme Verlag KG Stuttgart · New York.

  19. A novel balloon assisted two-stents telescoping technique for repositioning an embolized stent in the pulmonary conduit.

    Science.gov (United States)

    Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J

    2014-08-01

    A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT. © 2014 Wiley Periodicals, Inc.

  20. Recurrence of Subacute Stent Thrombosis and In-Stent Restenosis during Five Months after Stent Implantation in the LAD. A Case Report.

    OpenAIRE

    島田, 弘英; 大和, 眞史; 櫻井, 俊平; 疋田, 博之; 池田, 修一

    2001-01-01

    A coronary stent was deployed in the left anterior descending artery of an 82-year-old woman with unstable angina.Recurrence of subacute stent thrombosis and in-stent restenosis occurred frequently during the five months after initial stent implantation.Balloon angioplasty and cutting balloon angioplasty failed to prevent these complications,but they ceased after re-stenting in the initial stent.In this case,tissue protrusion through the stent strut, deformation of the coil stent and inadequa...

  1. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)

    2011-08-15

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  2. Use of covered self-expandable stents for benign colorectal disorders in children.

    Science.gov (United States)

    Lange, Bettina; Sold, Moritz; Kähler, Georg; Wessel, Lucas M; Kubiak, Rainer

    2017-01-01

    There is a lack of experience with covered self-expandable stents for benign colorectal disorders in children. Five children (4M, 1F) with a median age of 5years (range, 6months-9years) who underwent treatment with covered self-expandable plastic (SEPSs) or self-expandable metal stents (SEMSs) for a benign colorectal condition between April 2005 and November 2013 were recruited to this retrospective study. Etiologies included: anastomotic stricture with (n=1) or without (n=3) simultaneous enterocutaneous fistula, as well as an anastomotic leak associated with enterocutaneous fistula (n=1). All children suffered from either Hirschsprung's disease (n=3) or total colonic aganglionosis (Zuelzer-Wilson syndrome) (n=2). Median duration of individual stent placement was 23days (range, 1-87days). In all cases up to five different stents were placed over time. At follow-up two patients were successfully treated without further intervention. In another patient the anastomotic stricture resolved fully, but a coexisting enterocutaneous fistula persisted. Overall, three patients did not improve completely following stenting and required definite surgery. Stent-related problems were noted in all cases. There was one perforation of the colon at stent insertion. Further complications consisted of stent dislocation (n=4), obstruction (n=1), formation of granulation tissue (n=1), ulceration (n=1) and discomfort (n=3). Covered self-expandable stents enrich the armamentarium of interventions for benign colorectal disorders in children including anastomotic strictures and intestinal leaks. A stent can be applied either as an emergency procedure (bridge to surgery) or as an adjuvant treatment further to endoscopy and dilatation. Postinterventional problems are frequent but there is a potential for temporary or definite improvement following stent insertion. Copyright © 2017. Published by Elsevier Inc.

  3. Collapse of the balloon-expandable stent in the common iliac artery due to minor external compression in a lean patient

    International Nuclear Information System (INIS)

    Park, Sung Eun; Choi, Ho Cheol; Choi, Dae Seob; Lee, Sang Min; Lee, Jung Eun; Cho, Su Beom; Ahn, Jong Hwa

    2017-01-01

    A 60-year-old lean man with claudication due to severe stenosis of the right common iliac artery (CIA) underwent balloon-expandable stent deployment. Nineteen months later, claudication and lower limb ischemia in the patient recurred after minor external pressure and computed tomography indicated collapse of the right CIA stent. We performed balloon angioplasty again and self-expandable stent deployment was performed, and the patient's symptoms were relieved. We suggest that the CIA in a lean person could be susceptible to external pressure

  4. Clinical Application of Fully Covered Self-Expandable Metal Stents in the Treatment of Bronchial Fistula.

    Science.gov (United States)

    Cao, Ming; Zhu, Qiang; Wang, Wei; Zhang, Tian Xiao; Jiang, Min Zhong; Zang, Qi

    2016-09-01

    Background The study was designed to access the feasibility, safety, and efficacy of fully covered self-expandable metal stents in the treatment of bronchial fistula. Methods Clinical data of nine patients (seven males and two females) who were treated with placement of tracheobronchial or bronchial fully covered self-expandable metal stents from August 2005 to November 2011 were analyzed retrospectively. Among these patients, seven were diagnosed with bronchopleural fistula, one with tracheopleural fistula, and one with left main bronchoesophageal fistula. Eight had accompanying thoracic empyema. The fistula orifices ranged from 3.5 mm to 25 mm in diameter. All patients received topical anesthesia. L-shaped stents were placed in six patients and I-shaped stents in three under fluoroscopic guidance. After stent placement, patients with empyema were treated with pleural lavage. Results Stent placement in the tracheobronchial tree was successful in all patients, without procedure-related complications. The operating time was 5 to 16 minutes. A small amount of bubble overflowed from the intrathoracic drainage tube of only one patient. In the other patients, the bubble in the intrathoracic drainage tube disappeared immediately or angiography showed no overflow of contrast agent from the fistula orifice. The effective rate of fistula orifice closure after stent placement was 100%, with 88.9% rated as excellent. One patient coughed the stent out 5 days after placement and hence a new stent was placed. Among the patients with empyema, one died of septicemia arising from empyema on day 8 and another died of brain metastases of lung cancer 6 months after stent insertion with persistent empyema. In the other six patients, empyema resolved after 2 to 5 months (cure rate 75%). Seven patients were followed up for 3 to 36 months. During follow-up, one stent was removed 8 months after implantation due to difficult expectoration, without recurrent empyema. The remaining

  5. Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.

    Science.gov (United States)

    Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae

    2008-12-01

    To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.

  6. Delayed cerebral infarction due to stent folding deformation following carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kwon Duk; Lee, Kyung Yul; Suh, Sang Hyun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established method of managing this rare complication exists, a conservative approach was taken with administration of anticoagulant and dual antiplatelet therapy. No neurological symptoms were observed during several months of clinical follow-up after discharge.

  7. Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

    International Nuclear Information System (INIS)

    Saguner, Ardan M.; Traupe, Tobias; Räber, Lorenz; Hess, Nina; Banz, Yara; Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M.

    2012-01-01

    Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5–6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into “normal-sized” (stent-to-artery-ratio < 1.4, n = 12) and “oversized” (stent-to-artery-ratio ≥ 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

  8. Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty

    International Nuclear Information System (INIS)

    Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D.; Zeller, Thomas; Coerper, Stephan; Beckert, Stefan; Balletshofer, Bernd

    2007-01-01

    The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 ± 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)

  9. Creation of individual ideally shaped stents using multi-slice CT: in vitro results from the semi-automatic virtual stent (SAVS) designer

    International Nuclear Information System (INIS)

    Hyodoh, Hideki; Katagiri, Yoshimi; Hyodoh, Kazusa; Akiba, Hidenari; Hareyama, Masato; Sakai, Toyohiko

    2005-01-01

    To plan stent-grafting for thoracic aortic aneurysm with complicated morphology, we created a virtual stent-grafting program [Semi Automatic Virtual Stent (SAVS) designer] using three-dimensional CT data. The usefulness of the SAVS designer was evaluated by measurement of transformed anatomical and straight stents. Curved model images (source, multi-planer reconstruction and volume rendering) were created, and a hollow virtual stent was produced by the SAVS designer. A straight Nitinol stent was transformed to match the curved configuration of the virtual stent. The accuracy of the anatomical stent was evaluated by experimental strain phantom studies in comparison with the straight stent. Mean separation length was 0 mm in the anatomical stent [22 mm outer diameter (OD)] and 5 mm in the straight stent (22 mm OD). The straight stent strain voltage was four times that of the anatomical stent at the stent end. The anatomical stent is useful because it fits the curved structure of the aorta and reduces the strain force compared to the straight stent. The SAVS designer can help to design and produce the anatomical stent. (orig.)

  10. Gastric and Duodenal Stents: Follow-Up and Complications

    International Nuclear Information System (INIS)

    Pinto Pabon, Isabel Teresa; Paul Diaz, Laura; Ruiz de Adana, Juan Carlos; Lopez Herrero, Julio

    2001-01-01

    Purpose: To assess the efficacy of self-expanding metallic stents in treating inoperable gastric and duodenal stenoses during follow-up and to evaluate the complications encountered.Methods: A total of 31 patients suffering from gastroduodenal obstruction (29 malignant, 2 benign) were treated with a self-expanding metallic stent (Wallstent). In 24 cases insertion was by the peroral route, in seven cases via gastrostomy.Results: All the strictures were successfully negotiated under fluoroscopic guidance without having to resort to endoscopy. A total of 27 patients (87%) were able to resume a regular diet, a soft diet, or a liquid diet orally. Complications included one case of stent malpositioning, one case of leakage of ascitic fluid through the gastrostomy orifice, one case of perforation and fistula to the biliary tree, and two cases of hematemesis. In two patients (6%) additional stents were implanted to improve patency. In all patients follow-up was maintained until death. Recurrence of symptoms immediately before death occurred in seven cases (23%). Mean survival time of patients was 13.3 weeks (SE ± 4.6).Conclusions: The deployment of gastroduodenal stents resulted in good palliation of inoperable gastric and duodenal stenoses. Certain technical aspects, e.g., adaptation of stents to bowel morphology, is critical to proper stent function and avoidance of complications

  11. Renal Transplant Ureteral Stenosis: Treatment by Self-Expanding Metallic Stent

    International Nuclear Information System (INIS)

    Cantasdemir, Murat; Kantarci, Fatih; Numan, Furuzan; Mihmanli, Ismail; Kalender, Betul

    2003-01-01

    We report the use of a metallic stent in a transplant ureteral stenosis. A 28-year-old man with chronic renal failure due to chronic pyelonephritis, who received a living-donor renal transplant, presented with transplant ureteral stenosis. The stenosis was unresponsive to balloon dilation and was treated by antegrade placement of a self-expanding Memotherm stent. The stentedureter stayed patent for 3 years. It may be reasonable to treat post-transplant ureteral stenosis resistant to balloon dilation with self-expanding metallic stents. However, long-term follow-up is required to evaluate the efficacy of this treatment

  12. Collapse of the balloon-expandable stent in the common iliac artery due to minor external compression in a lean patient

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Eun; Choi, Ho Cheol; Choi, Dae Seob; Lee, Sang Min; Lee, Jung Eun [Gyeongsang National University School of Medicine and Gyeongsang National University Hospital, Jinju (Korea, Republic of); Cho, Su Beom; Ahn, Jong Hwa [Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon (Korea, Republic of)

    2017-08-15

    A 60-year-old lean man with claudication due to severe stenosis of the right common iliac artery (CIA) underwent balloon-expandable stent deployment. Nineteen months later, claudication and lower limb ischemia in the patient recurred after minor external pressure and computed tomography indicated collapse of the right CIA stent. We performed balloon angioplasty again and self-expandable stent deployment was performed, and the patient's symptoms were relieved. We suggest that the CIA in a lean person could be susceptible to external pressure.

  13. Biliary self-expandable metallic stent using single balloon enteroscopy assisted ERCP: overcoming limitations of current accessories

    Directory of Open Access Journals (Sweden)

    Rolando Pinho

    2013-10-01

    Full Text Available Device assisted enteroscopy (DAE techniques have been recently developed for the diagnosis and treatment of small bowel diseases. These techniques can also be used to perform endoscopic retrograde cholangiopancreatography (ERCP in patients with surgically altered anatomies. The main difficulties with DAE-ERCP are related to type of surgery, to the different dimensions and lack of frontal view of the enteroscope and to the resulting limitations with the use of standard accessories, resulting in the need of dedicated accessory devices. Although most ERCP techniques have been successfully performed with DAE-ERCP, biliary self-expandable metallic stents (SEMS have not yet been used, as dedicated biliary SEMS for the enteroscope are lacking. The authors present a case report showing a new method to place standard biliary trough-the-scope SEMS with DAE-ERCP, using a different technique of stent deployment.

  14. Reconstructive treatment of dural arteriovenous fistulas of the transverse and sigmoid sinus: transvenous angioplasty and stent deployment

    International Nuclear Information System (INIS)

    Liebig, T.; Henkes, H.; Brew, S.; Miloslavski, E.; Kuehne, D.; Kirsch, M.

    2005-01-01

    Various techniques for the endovascular treatment of dural arteriovenous fistulas (dAVFs) of the transverse and sigmoid sinus have recently evolved. Transvenous coil occlusion of the involved segment and transarterial embolization of the feeding arteries with liquid agents are the commonest treatments utilized. However, with respect to venous hypertension as the probable pathogenic cause of this disorder, a nonocclusive or remodeling technique might be preferable. We will present a series involving four patients, treated with transvenous angioplasty and stent deployment as a definitive treatment of dAVFs of the transverse and sigmoid sinus. This method was used as a primary treatment or as an adjunct to previous noncurative transarterial n-butyl cyanoacrylate and particle embolization. In three of the four cases, complete occlusion of the fistula was achieved with confirmation of occlusion seen on follow-up angiographical studies. In one case a negligible and nonsymptomatic remnant of the fistula fed by the tentorial artery was left untreated. From our experience, we conclude that transvenous stent deployment is an alternative to traditional concepts. Additionally, the pathological theory of dAVFs in this region located in venous pouches of the sinus wall is supported by the fact that they can be occluded by mechanical compression during angioplasty and subsequently maintained by a stent. (orig.)

  15. A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Werner; Kuehne, Dietmar [Alfried Krupp Hospital, Department of Radiology and Neuroradiology, Essen (Germany); Bendszus, Martin; Solymosi, Laszlo [University of Wuerzburg, Department of Neuroradiology, Wuerzburg (Germany); Kis, Bernhard [University of Duisburg-Essen, Research Unit, Rheinische Kliniken Essen, Department of Psychiatry and Psychotherapy, Essen (Germany); Boulanger, Thierry [Centre Hospitalier of Luxembourg, Service of Neuroradiology, Luxembourg (Luxembourg)

    2007-07-15

    We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were retreated. At the 6-month follow-up, 29 parent arteries were unaffected, whereas two parent vessels demonstrated minor asymptomatic narrowing at the stent site. Two patients experienced one or more possible or probable device-related serious adverse events during the 6-month follow-up period. There was no procedural morbidity or mortality at 6 months after the procedure. The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable. (orig.)

  16. Comparison of visibility for four self-expanding nitinol bare stents in vitro

    International Nuclear Information System (INIS)

    Wiesinger, Benjamin; Stutz, Alexander; Schmehl, Joerg; Groezinger, Gerd; Claussen, Claus Detlef; Wiskirchen, Jakub

    2012-01-01

    Background Sufficient radiopacity of stents is a prerequisite for safe interventions and minimization of the radiation dose for the patient and the interventionist. Modern nitinol stents are considered less radiopaque compared to formerly used stents. Purpose To evaluate the objective detection rate (ODR) and the subjective radiopacity score (SRS) of four self-expanding nitinol stents with their markers on a phantom human pelvis. Material and Methods We evaluated the ODR (as a percentage of correctly identified stents) and the SRS (on a scale from 0 = not visible to 4 = excellent visibility) for four self-expanding nitinol stents (SinusSuperflex, SMART, Luminexx, Zilver) with 8 mm diameter and 40 mm length. Stents were placed on a phantom human pelvis and images of the stents were taken in four different positions (right and left lumbosacral joint and near the right and left limbus acetabuli) using the following modes: spotfilm, pulsed fluoroscopy (4, 7.5, 15, and 30 pulses/min) and at three different digital magnification modes. Dose area products (DAPs) were assessed. Results ODR and SRS, respectively, were significantly increased for the SMART stent compared to all other tested stents (P < 0.05): SMART 93.53% and 2.43, SinusSuperflex 90.81% and 2.21, Luminexx 90.39% and 2.20, and Zilver 89.28% and 2.21. ODR was significantly reduced in position 3 where the bone overlap was more pronounced for all stents (detection rates 77.14-79.56%). An increase in magnification significantly improved the ODR and SRS for all stents (70.33-99.25% and 1.07-3.28, respectively, P < 0.05). Increased pulsing frequency did not improve the ODR of the various stents but did increase the DAP. Conclusion The SMART stent had the best overall performance. In the presence of bone overlap, all self-expanding nitinol stents had poor results. Increased pulsing frequency did not improve ODR or SRS but did increase the DAP. Use of digital magnification modes had no effect on DAP increasing ODR

  17. Treatment of tracheobronchial stenosis with a self-expandable metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Soo; Jeon, Seok Chol; Choi, Chul Seung; Choi, Yo Won; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1994-07-15

    We analysed the role of modified Gianturco self-expandable stents in the treatment of tracheobronchial stenosis in 13 patients. We inserted modified Gianturco self-expandable stents under the fluoroscopic and bronchoscopic guidance. There were stenosis in the trachea(n=2), the right main bronchus(n=2), and the left main bronchus(n=9). The causes of the stenosis were endobronchial tuberculosis(n=10), intubation granuloma(n=1), restenosis after surgical reconstruction(n=2). Dyspnea or wheezing was improved within 1 or 2 days following the procedure. There were 32% and 22% respective increase in average FEV1 and FVC. Lung perfusion scan showed 9.6% increase of perfusion in the involved lung. No complications related to the procedure were encountered. During follow-up period of up to 31 months, 2 patients showed tracheal or bronchial restenosis, at 3 and 6 months, retrospectively. There was a distal migration of the stents in one case. During the follow up period after stent insertion, improvement of the obstructive changes and dyspnea persisted in 10 out of 13 patients. The modified Gianturco self-expandable metallic stents may be a good choice for the treatment of tracheobronchial stenosis, either as a primary treatment, or when the reconstruction failed.

  18. A fully covered self-expandable metal stent with antimigration features for benign biliary strictures : a prospective, multicenter cohort study

    NARCIS (Netherlands)

    Walter, Daisy; Laleman, Wim; Jansen, Jeroen M; van Milligen de Wit, A W M; Weusten, Bas L; van Boeckel, Petra G; Hirdes, Meike M; Vleggaar, FP; Siersema, Peter D

    2015-01-01

    BACKGROUND: Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. OBJECTIVE: To evaluate the efficacy of a novel

  19. A fully covered self-expandable metal stent with antimigration features for benign biliary strictures: a prospective, multicenter cohort study

    NARCIS (Netherlands)

    Walter, D.; Laleman, W.; Jansen, J.M.; Milligen de Wit, A.W. van; Weusten, B.L.; Boeckel, P.G. van; Hirdes, M.M.; Vleggaar, F.P.; Siersema, P.D.

    2015-01-01

    BACKGROUND: Self-expandable metal stents (SEMSs) are increasingly used for the treatment of benign biliary strictures (BBSs). A new fully covered SEMS (FCSEMS) with flared ends and high conformability was designed to prevent migration of the stent. OBJECTIVE: To evaluate the efficacy of a novel

  20. Development of tissue-engineered self-expandable aortic stent grafts (Bio stent grafts) using in-body tissue architecture technology in beagles.

    Science.gov (United States)

    Kawajiri, Hidetake; Mizuno, Takeshi; Moriwaki, Takeshi; Ishibashi-Ueda, Hatsue; Yamanami, Masashi; Kanda, Keiichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2015-02-01

    In this study, we aimed to describe the development of tissue-engineered self-expandable aortic stent grafts (Bio stent graft) using in-body tissue architecture technology in beagles and to determine its mechanical and histological properties. The preparation mold was assembled by insertion of an acryl rod (outer diameter, 8.6 mm; length, 40 mm) into a self-expanding nitinol stent (internal diameter, 9.0 mm; length, 35 mm). The molds (n = 6) were embedded into the subcutaneous pouches of three beagles for 4 weeks. After harvesting and removing each rod, the excessive fragile tissue connected around the molds was trimmed, and thus tubular autologous connective tissues with the stent were obtained for use as Bio stent grafts (outer diameter, approximately 9.3 mm in all molds). The stent strut was completely surrounded by the dense collagenous membrane (thickness, ∼150 µm). The Bio stent graft luminal surface was extremely flat and smooth. The graft wall of the Bio stent graft possessed an elastic modulus that was almost two times higher than that of the native beagle abdominal aorta. This Bio stent graft is expected to exhibit excellent biocompatibility after being implanted in the aorta, which may reduce the risk of type 1 endoleaks or migration. © 2014 Wiley Periodicals, Inc.

  1. Physical property and MR imaging of self-expandable metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee; Kang, Sung Gwon; Cho, Young Kook; Kim, Hyung Jin; Lim, Myung Kwan; Cho, Soon Gu; Yoh, Kyu Tong; Suh, Chang Hae [Inha Univ., College of Medicine, Seoul (Korea, Republic of)

    1998-09-01

    In order to furnish basic information prior to their use, the physical properties of various self-expandable metallic stents and their MR characteristics were evaluated. Four commercially available self-expandable metallic stents-Gianturco-the Rosch, Hanaro, Memotherm, and Wallstent-were used in this study. For evaluation of the physical properties of each, hoop strengths and changes in radii according to the degrees of longitudinal flexion were compared. Stent characteristics seen on MR images were evaluated by measuring magnetic torque and by comparing images obtained in the vascular phantom using SE T1TI, FSE T2WI, and FMPSPGR sequences. These images were analyzed with special emphasis on artifact size and the apparant shepe of the stent. Hoop strength was greatest in the Gianturco-Rosch stent, followed by the Memotherm, Hanaro, and Wallstent. When flexed in the longitudinal axis, the radius of the Hanaro and Memotherm stent decreased slightly as a larger flexion angle was applied. When this was 90 deg, however, the connection of the Gianturco-Rosch stent collapsed. In contrast, the radius of the Wallstent became larger as a larger flexion angle was applied. At the portal of the MR imaging unit, neither the Memotherm nor Wallstent showed deflection; except for a thin hyperintense rim at both ends, their images were excellent, and the lumina of these stents were also clearly seen. In contrast, the Gianturco-Rosch and Hanaro stent demonstrated large deflexion and showed a severe black-hole artifact. As a result, visualization of the stents themselves and their lumina was impossible. The Gianturco-Rosch stent showed greatrer hoop strength than the others. The Wallstent showed good longitudinal flexibility and was thought to be effective in tortuous vessels. For follow-up after placement, especially when the nonferromagnetic Memotherm and Wallstent are used, MR imaging appears to be safe and useful.=20.

  2. Self-Expandable Metallic Stent Placement for the Palliation of Esophageal Cancer.

    Science.gov (United States)

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho Young; Kim, Pyeong Hwa; Park, Jung Hoon

    2017-07-01

    Esophageal stents have been used to palliate patients with dysphagia caused by esophageal cancer. Early rigid plastic prostheses have been associated with a high risk of complications. However, with the development of self-expanding stents, it has developed into a widely accepted method for treating malignant esophageal strictures and esophagorespiratory fistulas (ERFs). The present review covers various aspects of self-expanding metallic stent placement for palliating esophageal cancer, including its types, placement procedures, indications, contraindications, complications, and some of innovations that will become available in the future. © 2017 The Korean Academy of Medical Sciences.

  3. Distal Marginal Stenosis: A Contributing Factor in Delayed Carotid Occlusion of a Patient With Carotid Blowout Syndrome Treated With Stent Grafts

    Directory of Open Access Journals (Sweden)

    Feng-Chi Chang

    2010-05-01

    Full Text Available Distal marginal stenosis is rarely reported to be a factor associated with poor long-term patency of patients of head and neck cancers with carotid blowout syndrome treated with stent grafts. We report a case of laryngeal cancer with rupture of the right common carotid artery. A self-expandable stent graft was deployed, but bleeding recurred. Another stent graft was deployed for the pseudoaneurysm located distal to the first stent graft. Rebleeding occurred because of pseudoaneurysm formation from reconstituted branches of the right superior thyroid artery. We performed direct percutaneous puncture of the proximal superior thyroid artery for successful embolization. Distal marginal stenosis and asymptomatic thrombosis of the carotid artery were noted at 3.5- and 5-month follow-ups, respectively. We suggest aggressive early follow-up and reintervention for distal marginal stenosis by combined antibiotic therapy and angioplasty and stenting to improve the long-term patency of stent-graft deployment for management of carotid blowout syndrome.

  4. Esophageal carcinoma treatment with self-expanding covered stent implanted in esophagus

    International Nuclear Information System (INIS)

    Liu Mingguo; Ji Yan; He Nengwei

    2006-01-01

    Objective: To investigate the clinical significance of the treatment to esophageal cancer by self- expanding covered stent implanted into esophagus. Methods: Under fluoroscopic guidance and with guidance wire , 20 self-expanding covered stents were implanted into stenotic part of esophagus to recanalize the esophagus, then follow up to observe the clinical symptom improved. Results: Technical success was obtained 20 cases without any complication. Clinical symptom were improved in shot time. Conclusions: self-expanding covered stent is implanted in stenotic part of esophageal carcinoma to treat esophageal stenosis and enable to improved clinical symptom in shot time, if combined with transcatheter arterial infusion and embolization, Radiotherapy, Chinese medical treatment, it enable to lengthen life time remarkably. (authors)

  5. Endoscopic removal and trimming of distal self-expandable metallic biliary stents

    Science.gov (United States)

    Ishii, Kentaro; Itoi, Takao; Sofuni, Atsushi; Itokawa, Fumihide; Tsuchiya, Takayoshi; Kurihara, Toshio; Tsuji, Shujiro; Ikeuchi, Nobuhito; Umeda, Junko; Moriyasu, Fuminori; Tsuchida, Akihiko

    2011-01-01

    AIM: To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents (SEMS). METHODS: All SEMS had been placed for distal biliary strictures. Twenty-seven endoscopic procedures were performed in 19 patients in whom SEMS (one uncovered and 18 covered) removal had been attempted, and 8 patients in whom stent trimming using argon plasma coagulation (APC) had been attempted at Tokyo Medical University Hospital. The APC settings were: voltage 60-80 W and gas flow at 1.5 L/min. RESULTS: The mean stent indwelling period for all patients in whom stent removal had been attempted was 113.7 ± 77.6 d (range, 8-280 d). Of the 19 patients in whom removal of the SEMS had been attempted, the procedure was successful in 14 (73.7%) without procedure-related adverse events. The indwelling period in the stent removable group was shorter than that in the unremovable group (94.9 ± 71.5 d vs 166.2 ± 76.2 d, P = 0.08). Stent trimming was successful for all patients with one minor adverse event consisting of self-limited hemorrhage. Trimming time ranged from 11 to 16 min. CONCLUSION: Although further investigations on larger numbers of cases are necessary to accumulate evidence, the present data suggested that stent removal and stent trimming is feasible and effective for stent-related complications. PMID:21677835

  6. Long-term outcome of self expandable metal stents for biliary obstruction in chronic pancreatitis.

    Science.gov (United States)

    Waldthaler, Alexander; Schütte, Kerstin; Weigt, Jochen; Kropf, Siegfried; Malfertheiner, Peter; Kahl, Stefan

    2013-01-10

    Insertion of a self-expandable metal stent is still controversial for treatment of benign common bile duct stenosis but can be a valuable alternative to surgical treatment. Aim of our study was to analyze the efficacy of covered and uncovered self-expandable metal stent in patients with chronic pancreatitis and common bile duct stenosis. Twenty patients with common bile duct stenosis due to alcoholic chronic pancreatitis were retrospective analyzed. All patients had advanced chronic pancreatitis, presenting with calcifications in pancreatic head. Uncovered self-expandable metal stent (uSEMS) were used in 11 patients (3 females, 8 males) while in 9 patients (3 females, 6 males) partially covered self-expandable metal stent (cSEMS) were inserted. All patients treated with self-expandable metal stent had contraindications for surgery. Overall mean follow up time was 155 weeks: 206 (52-412) weeks in uSEMS, and 93 (25-233) weeks in cSEMS, respectively. Stent patency was in mean 118 weeks: 159 (44-412) weeks in uSEMS and 67 (25-150) weeks in cSEMS (P=0.019). In the uSEMS group, reintervention was necessary in 5 patients (45%) due to stent obstruction, whereas in the cSEMS group 4 patients (44%) needed reintervention (2 obstructions, 2 migration). Stent migration is an early complication, compared to obstruction (P<0.05), and in cSEMS obstruction occurred significantly earlier compared to uSEMS (P<0.05). Patency of uSEMS was significantly longer compared to partially cSEMS. Available self-expandable metal stent, unfortunately, do not meet the demands on successful treatment of benign common bile duct stenosis.

  7. Self-expandable metal stents for relieving malignant colorectal obstruction: short-term safety and efficacy within 30 days of stent procedure in 447 patients

    DEFF Research Database (Denmark)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G

    2011-01-01

    The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery.......The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery....

  8. Outcomes of secondary self-expandable metal stents versus surgery after delayed initial palliative stent failure in malignant colorectal obstruction.

    Science.gov (United States)

    Yoon, Jin Young; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee

    2013-01-01

    When re-intervention is required due to an occluded first colorectal self-expanding metal stent for malignant colorectal obstruction, serious controversies exist regarding whether to use endoscopic re-stenting or surgery. To compare the clinical outcomes in patients who underwent stent re-insertion versus palliative surgery as a second intervention. A total of 115 patients who received either self-expandable metal stent (SEMS) insertion or palliative surgery for treatment of a second occurrence of malignant colorectal obstruction after the first SEMS placement were retrospectively studied between July 2005 and December 2009. The median overall survival (8.2 vs. 15.5 months) and progression-free survival (4.0 vs. 2.7 months) were not significantly different between the stent and surgery groups (p = 0.895 and 0.650, respectively). The median lumen patency in the stent group was 3.4 months and that in the surgery group was 7.9 months (p = 0.003). The immediate complication rate after second stent insertion was 13.9% and late complication rate was observed in 12 of 79 (15.2%) patients. There was no mortality related to the SEMS procedure. The complication and mortality rates associated with palliative surgery were 3.5% (2/57) and 12.3% (7/57), respectively. Although there is no significant difference in the overall survival between stenting and surgery, a secondary stent insertion had a lower mortality rate despite a shorter duration of temporary colorectal decompression compared to that of palliative surgery.

  9. Square Stent: A New Self-Expandable Endoluminal Device and Its Applications

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Uchida, Barry; Timmermans, Hans; Keller, Frederick S.; Roesch, Josef

    2001-01-01

    The square stent is a new, simply constructed, self-expanding device that has recently been described. Compared with other stents, the square stent has a minimal amount of metal and thus requires a smaller-diameter catheter for introduction. Despite the small amount of metal present, the square stent has adequate expansile force. We have been evaluating the square stent for various interventional applications. In addition to the basic square stent, combinations of square stents and coverings for square stents were developed and evaluated to expand its uses and indications. One of the coverings tested is a new biomaterial: small intestinal submucosa (SIS). This paper will discuss the various applications of the square stent, which include a retrievable inferior vena cava filter, vascular occluder, graft adapter, and venous and aortic valves. In addition, we will review the important properties of SIS as a covering for the square stent

  10. Self-expendable metallic stents for palliative treatment of malignant esophagogastric strictures: experiences in 103 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Ah; Do, Young Soo; Lee, Byung Hee; Oh, Hoon Il; Kim, Soo Ah; Kim, Ki Soo; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the effects and complication of self-expandable metallic stent for the treatment of malignant esophagogastric strictures. From September 1991 to March 1995, 110 stents were placed under fluoroscopic guidance in 103 patients. Of the 103 patients, there were 73 patients with esophageal cancer, 14 patients with gastric cancer, 12 patients with recurrence after surgery, three patients with esophageal compression by metastatic mediastinal lymphadenopathy, and one patient with esophageal invasion by lung cancer. Seventeen patients had esophagorespiratory fistulas. Under fluoroscopic guidance, 113 self-expandable metallic stents (99 Song stents, 14 Strecker stents) were placed in 103 patients. After stent placement, 68 (66%) of the patients could ingest solid food, 26 (25.2%) could ingest soft food whereas three (2.9%) were not able to have food. Esophagorespiratory fistulas were occluded immediately after stent insertion. All stents were placed without any technical failures or procedural morbidity or mortality. Complications included restenosis in 13, gastroesophageal reflux in 11, stent tube migration in eight, massive bleeding in four, delayed esophageal perforation in one, stent obstruction by food impaction in one patient. Self-expandable metallic stent seems to be relatively safe and effective procedure in the palliative treatment of malignant esophagogastric stricture.

  11. Safety and efficacy of self-expandable metal stents for obstructive proximal and distal large bowel cancer.

    Science.gov (United States)

    Mitra, V; Hu, M; Majumdar, D; Krishnan, V; Chaudhury, B; Hancock, J; Dwarakanath, D

    2017-03-01

    Self-expandable metal stents are often used to treat obstructive large bowel cancers. This study assessed the safety and efficacy of colonic stent insertion carried out in a district general hospital. Methods A retrospective review was carried out between 1 January 2007 and 28 February 2014 to identify patients who underwent stent insertion for malignant colorectal obstruction. Results Seventy-five patients (median age 75.2 years, 70.6% male) with primary colorectal cancer underwent stent insertion - 53 underwent semi-elective self-expanded metal stent insertion (for subacute bowel obstruction) and 22 had emergency stent inserted (for acute bowel obstruction). The majority (88%) had self-expanded metal stents inserted for palliation. Technical and clinical success rates were 98.7% and 91.2%, respectively. One patient had stent-related perforation; there was no procedure-related mortality. Conclusion This study shows that self-expanded metal stent insertion in malignant colorectal obstruction is safe and effective and can be successfully delivered in a district general hospital with high technical and clinical success rates.

  12. An unusual case of aortic rupture after deployment of a bare stent in the treatment of aortic dissection in a patient with giant-cell arteritis.

    Science.gov (United States)

    Rynio, Pawel; Kazimierczak, Arkadiusz; Gutowski, Piotr; Cnotliwy, Miloslaw

    2017-06-01

    Giant-cell arteritis is associated with a higher risk of aortic aneurysm and aortic dissection formation. We present a women with aortic dissection type B treated with a stent graft and bare-metal stent implantation. After the stent deployment we noticed aortic rupture, which was successfully treated with implantation of an additional stent graft. This report highlights the difficulty of endovascular therapy in patients with giant-cell arteritis. We have to bear in mind that chronic inflammation of the aorta leads to a more fragile aortic wall than normal. We recommend the use of a stent graft over a bare-metal stent and gentle use of a balloon catheter.

  13. Animal experimental study of safety for a self-made vena cava stent-filter

    International Nuclear Information System (INIS)

    Qin Dingwen; Shi Haibin; Liu Sheng; Li Linsun

    2008-01-01

    Objective: To evaluate the safety of a self-made vena cava stent-filter(VCSF)for prevention of pulmonary embolism. Methods: Fusiform unmhrella-like vena cava filter was made of Nitinol wires and stainless steel metal pole, and then ten mongrel dogs were implanted with these self-made filters and divided into 5 groups according to the different periods (2, 3, 4, 5 and 6 w) of filter placement, with 2 dogs in each group. After the VCSFs were placed in inferior vena cava via the right femoral vein approach, the dogs in each group were bred for 2-6 weeks, respectively. The blood flow of inferior vena cava and the position of the filters were inspected by inferior vena-cavography according to the indwelling periods. Finally the metal pole was retrieved via the femoral vein, leaving the VCSF as permanent venousz stent. The feasibility of retrieval and the free state of filter net with the adhering vascular wall were evaluated. Laparotomies were performed to remove the inferior vena cava from the animals for gross and electron microscopic examinations of the inferior vena cava intimal changes of the involved segment. Results: All 10 VCSFs were placed at the right positions of the dogs successfully. Angiography showed patent inferior vena cava without filter thrombosis at 2-6 weeks. There were no tilting and migration of the filter and all the metal poles were successfully retrieved. The superior and inferior extremities of filter nets could be set free with all the filters turning into venous stents. Postmortem displayed retroperitoneal hemorrhage and caval thrombosis. The barbs of the filters penetrated over the caval adventitial coat. Under electron microscope, a thin layer of neointima already covered the braiding net of VCSFs at 2 weeks after the deployment. The tunica intima became slightly thick at 3-4 weeks and with moderate proliferation at 5-6 weeks. Conclusions: The self-made vena cava stent-filter possesses rather long indwelling period according to the

  14. Bilateral metal stents for hilar biliary obstruction using a 6Fr delivery system: outcomes following bilateral and side-by-side stent deployment.

    Science.gov (United States)

    Law, Ryan; Baron, Todd H

    2013-09-01

    Controversy exists on optimal endoscopic management for palliation of malignant hilar obstruction, with advocates for metal "side-by-side" (SBS) and "stent-in-stent" (SIS) techniques. We sought to evaluate the technical feasibility, efficacy, and outcomes of bilateral biliary self-expanding metal stents (SEMS) for treatment of malignant hilar obstruction using a stent with a 6Fr delivery system. This was a single-center, retrospective review of all patients who underwent bilateral placement of Zilver® biliary SEMS for malignant hilar obstruction from January 2010 to August 2012. Patients underwent endoscopic retrograde cholangiopancreatography with placement of stents using either the SIS or SBS stent techniques. Twenty-four patients (19 men, mean age 63 years) underwent bilateral stenting for malignant hilar obstruction during the study period. Seventeen and seven patients underwent the SBS and SIS technique, respectively. Cholangiocarcinoma (n=14) was the most common cause of hilar obstruction. Initial technical success was achieved in 24/24 (100%) of patients; however, 12 (50%) patients required re-intervention during the study period (median 98 days). Comparison of the SBS and SIS groups revealed no statistical difference with respect to need for re-intervention (P=0.31), successful re-intervention (P=0.60), or procedural length (P=0.89). Use of bilateral Zilver® SEMS in either the SBS or SIS configuration is safe, technically feasible, and effective for drainage of malignant hilar obstruction; however, duration of stent patency and procedure-free survival remain variable.

  15. Long-Term Results after Placement of Aortic Bifurcation Self-Expanding Stents: 10 Year Mortality, Stent Restenosis, and Distal Disease Progression

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Bhat, Raj; Ross, Rose; Stonebridge, Peter A.

    2007-01-01

    Purpose. To retrospectively evaluate the 10 year follow-up results in patients who had 'kissing' self-expanding stent aortic bifurcation reconstruction. Methods. Forty-three patients were treated with 'kissing' self-expanding stents for aortoiliac occlusive disease. Early follow-up with clinical and ankle brachial pressure indices (ABPI) was performed at 3, 6, 12, and 24 months and with intra-arterial digital subtraction angiography at 12-24 months; clinical and angiographic follow-up was performed for symptom recurrence up to 10 years after treatment. Retrospective record review was performed to assess mortality, clinical patency, angiographic patency, and secondary assisted patency of both stents and downstream peripheral vessels at 5 and 10 years follow-up. Results. The 2 year primary angiographic and secondary assisted stent patencies were 89% and 93%, respectively. At 10 years follow-up in 40 patients the mortality was 38% (due to myocardial infarction, stroke, chronic renal failure, malignancy, and liver failure). At 5 and 10 years follow-up the primary clinical stent patency was 82% and 68%, and the secondary assisted stent patency 93% and 86%, respectively. At 5 and 10 years, the distal vessel patency was 86% and 72%, and the secondary assisted distal vessel patency treated by surgical or endovascular techniques was 94% and 88%, respectively. At 10 years there was no limb loss. Conclusion. The long-term (10 year) results of aortic bifurcation arterial self-expanding stent placement in patients with arterial occlusive disease show a 10 year primary stent patency rate of 68% but a secondary assisted patency rate of 86%. In addition there is a high overall mortality due to other cardiovascular causes and the rate of distal disease progression and loss of patency is similar to the loss of stent patency rate

  16. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.

    Science.gov (United States)

    Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Sato, Yuki; Hikichi, Takuto; Ohira, Hiromasa

    2017-09-14

    To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents (SEMSs). This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography (ERCP) procedures between the two groups. The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices (ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve (sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement.

  17. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na [Chonnam Univ. College of Medicine, Kwangju (Korea, Republic of)

    1999-04-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate.

  18. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    International Nuclear Information System (INIS)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na

    1999-01-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate

  19. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction.

    Science.gov (United States)

    Inoue, Tadahisa; Naitoh, Itaru; Okumura, Fumihiro; Ozeki, Takanori; Anbe, Kaiki; Iwasaki, Hiroyasu; Nishie, Hirotada; Mizushima, Takashi; Sano, Hitoshi; Nakazawa, Takahiro; Yoneda, Masashi; Joh, Takashi

    2016-11-01

    Endoscopic reintervention for stent occlusions following bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstruction (MHBO) is challenging, and time to recurrent biliary obstruction (RBO) of the revisionary stent remains unclear. We aimed to clarify a suitable reintervention method for stent occlusions following bilateral SEMS placement for MHBO. Between 2002 and 2014, 52 consecutive patients with MHBO who underwent endoscopic reintervention for stent occlusion after bilateral SEMS placement were enrolled at two university hospitals and one tertiary care referral center. We retrospectively evaluated the technical and functional success rates of the reinterventions, and the time to RBO of the revisionary stents. Technical and functional success rates of the reinterventions were 92% (48/52) and 90% (43/48), respectively. Univariate analysis did not determine any significant predictive factors for technical and functional failures. Median time to RBO of the revisionary stents was 68 days. Median time to RBO was significantly longer for revisionary SEMS placement than for plastic stent placement (131 days vs 47 days, respectively; log-rank test, P = 0.005). Revisionary SEMS placement was the only independent factor that was significantly associated with a longer time to RBO of the revisionary stent in the multivariate Cox proportional hazards analysis (hazard ratio 0.37; 95% confidence interval 0.14-0.95; P = 0.039). Revisionary SEMS placement is a suitable endoscopic reintervention method for stent occlusion following bilateral SEMS placement from the perspective of time to RBO of the revisionary stent. © 2016 Japan Gastroenterological Endoscopy Society.

  20. Efficacy of different types of self-expandable stents in carotid artery stenting for carotid bifurcation stenosis.

    Science.gov (United States)

    Liu, Ya-min; Qin, Hao; Zhang, Bo; Wang, Yu-jing; Feng, Jun; Wu, Xiang

    2016-02-01

    Both open and closed loop self-expandable stents were used in carotid artery stenting (CAS) for carotid bifurcation stenosis. We sought to compare the efficacy of two types of stents in CAS. The data of 212 patients treated with CAS (42 and 170 cases implanted with closed and open loop stents, respectively) for carotid bifurcation stenosis and distal filtration protection devices were retrospectively analyzed. Between closed and open loop stents, there were no significant differences in hospitalization duration, NIHSS score before and after the treatment, stenosis at 12th month, and cumulative incidence of primary endpoint events within 30 days or from the 31st day to the 12th month; while there were significant differences in hemodynamic changes and rate of difficulty in recycling distal filtration protection devices. Use of open vs. closed loop stents for carotid bifurcation stenosis seems to be associated with similar incidence of complications, except for greater rate of hemodynamic changes and lower rate of difficulty in recycling the distal filtration protection devices.

  1. Removal of self expandable metallic airway stent: A rare case report

    Directory of Open Access Journals (Sweden)

    Rakesh K Chawla

    2013-01-01

    Full Text Available Covered self expandable metallic airway stents (SEMS have been used for benign tracheal stenosis, post intubation tracheal stenosis, tracheal burn or trauma, tracheo-broncho-malacia, and extrinsic compression of trachea. Their placement is considered to be permanent, with open surgery the only way to remove the stent, though there are few cases reports of their removal with the bronchoscope, but the complications after their removal are very high. In our patient, one and a half years after placement of SEMS, she developed cough with dyspnoea, video bronchoscopy showed stenosis above the level of stent with granulation tissue inside the stent, stent fracture in lower part and stent migration to right main bronchus, thus she had all conceivable complications of stent placement. The stent was removed with the help of rigid bronchoscope under general anaesthesia. She was discharged the following day. The case is being reported because it was unique in having all the possible complications of stent placement, and rare as we could take out the stent in Toto. Thirdly, the stent could be removed without any complication.

  2. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  3. The use of self expandable metallic stent in the management of malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Han, Joon Koo; Choi, Byung Ihn; Chung, Jin Wook; Park, Jae Hyung; Han, Gi Seok; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-05-15

    Self expandable metallic stent is a good alternative of percutaneous transhepatic biliary drainage because it can eliminate numerous problems caused by external drainage catheter, such as tube dislodgement, bile leakage and psychotic problems. Authors analyzed initial results of self expandable metallic stents used in the patient with malignant biliary obstruction to evaluate the efficacy of the procedure and to find the technical problems in the procedure. Self expandable metallic stents were inserted in 14 patients: three with recurrent stomach cancer: three with gallbladder cancer: seven with Klaskin tumor: one with common duct cancer. Gianturco type stent was used in 9 cases ans Wallstent was used in 2 cases. In remaining three case, both Z-stent and Wallstent were used in the same patient. The average period of follow up was 104 days (4-409 days). In 13 cases, the patency of the bile duct was restored by the stent (technical success: 92.9%). Occlusions of the stent were found in two cases, after two and 13 months, respectively. Causes of failure and stent occlusion were associated duodenal obstruction, tumor overgrowth and shortening of Wallstent. In remaining 11 patients, one patient was lost to follow up an 10 patients did not show recurrent jaundice until death or last follow up. There was no major complication related to the procedure. The insertion of self expandable metallic stent is a safe procedure and can eliminate major disadvantages of PTBD. Overstenting, overlapping and evaluation of associated GI tract obstruction is crucial for obtaining technical success and long-term patency.

  4. The use of self expandable metallic stent in the management of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Han, Joon Koo; Choi, Byung Ihn; Chung, Jin Wook; Park, Jae Hyung; Han, Gi Seok; Han, Man Chung

    1993-01-01

    Self expandable metallic stent is a good alternative of percutaneous transhepatic biliary drainage because it can eliminate numerous problems caused by external drainage catheter, such as tube dislodgement, bile leakage and psychotic problems. Authors analyzed initial results of self expandable metallic stents used in the patient with malignant biliary obstruction to evaluate the efficacy of the procedure and to find the technical problems in the procedure. Self expandable metallic stents were inserted in 14 patients: three with recurrent stomach cancer: three with gallbladder cancer: seven with Klaskin tumor: one with common duct cancer. Gianturco type stent was used in 9 cases ans Wallstent was used in 2 cases. In remaining three case, both Z-stent and Wallstent were used in the same patient. The average period of follow up was 104 days (4-409 days). In 13 cases, the patency of the bile duct was restored by the stent (technical success: 92.9%). Occlusions of the stent were found in two cases, after two and 13 months, respectively. Causes of failure and stent occlusion were associated duodenal obstruction, tumor overgrowth and shortening of Wallstent. In remaining 11 patients, one patient was lost to follow up an 10 patients did not show recurrent jaundice until death or last follow up. There was no major complication related to the procedure. The insertion of self expandable metallic stent is a safe procedure and can eliminate major disadvantages of PTBD. Overstenting, overlapping and evaluation of associated GI tract obstruction is crucial for obtaining technical success and long-term patency

  5. Study on the application of big cup membranate stent on restenosis after stenting for carcinoma of esophago cardia

    International Nuclear Information System (INIS)

    Wang Xiuping; Yao Zhongqiang; Liu Jian; Zhang Yan

    2007-01-01

    Objective: To evaluate the clinical value of self-designed big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia. Methods: 12 cases of restenosis after stenting for carcinoma of esophago-cardia were involved in the study. Self-designed big cup membranate stent made by Nanjing Weichuang Company (the length of the cup was 3.5 cm)was placed into the constricted stent under guidance of fluoroscopy. Clinical effect, restenosis, and complications were observed during followed up. Results: All the 12 cases of big cup membranat stent placement went along smoothly without indigitation of the cup of the stent. Follow-up of 1.5-8 months showed that 2 cases developed severe restenosis on the big cup of the stem, resulting in third grade difficult deglutition. Among them, one occurred 1 month after stenting, caused by hyperplasia of large amount of granulation tissue; another occurred 6 months after stenting, caused by growth of tumor tissue. 3 cases developed mild to moderate restenosis, 2.3-7 months (mean: 4.6 months) after stenting, with result of first grade difficult deglutition. The remaining 7 cases (mean 5.6 months follow-up) did not have difficulty during deglutition. Conclusions: Application of big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia can effectively prevent the stent from moving downwards and thus lower down the rate of restenosis, and postpone the occurrence of restenosis. (authors)

  6. Biliary and pancreatic stenting: Devices and insertion techniques in therapeutic endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography

    Science.gov (United States)

    Mangiavillano, Benedetto; Pagano, Nico; Baron, Todd H; Arena, Monica; Iabichino, Giuseppe; Consolo, Pierluigi; Opocher, Enrico; Luigiano, Carmelo

    2016-01-01

    Stents are tubular devices made of plastic or metal. Endoscopic stenting is the most common treatment for obstruction of the common bile duct or of the main pancreatic duct, but also employed for the treatment of bilio-pancreatic leakages, for preventing post- endoscopic retrograde cholangiopancreatography pancreatitis and to drain the gallbladder and pancreatic fluid collections. Recent progresses in techniques of stent insertion and metal stent design are represented by new, fully-covered lumen apposing metal stents. These stents are specifically designed for transmural drainage, with a saddle-shape design and bilateral flanges, to provide lumen-to-lumen anchoring, reducing the risk of migration and leakage. This review is an update of the technique of stent insertion and metal stent deployment, of the most recent data available on stent types and characteristics and the new applications for biliopancreatic stents. PMID:26862364

  7. Predictors of the patency of self-expandable metallic stents in malignant gastroduodenal obstruction.

    Science.gov (United States)

    Kim, Seung Han; Chun, Hoon Jai; Yoo, In Kyung; Lee, Jae Min; Nam, Seung Joo; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2015-08-14

    To investigate the predictive factors of self-expandable metallic stent patency after stent placement in patients with inoperable malignant gastroduodenal obstruction. A total of 116 patients underwent stent placements for inoperable malignant gastroduodenal obstruction at a tertiary academic center. Clinical success was defined as acceptable decompression of the obstructive lesion within the malignant gastroduodenal neoplasm. We evaluated patient comorbidities and clinical statuses using the World Health Organization's scoring system and categorized patient responses to chemotherapy using the Response Evaluation Criteria in Solid Tumors criteria. We analyzed the relationships between possible predictive factors and stent patency. Self-expandable metallic stent placement was technically successful in all patients (100%), and the clinical success rate was 84.2%. In a multivariate Cox proportional hazards model, carcinoembryonic antigen (CEA) levels were correlated with a reduction in stent patency [P = 0.006; adjusted hazard ratio (aHR) = 2.92, 95%CI: 1.36-6.25]. Palliative chemotherapy was statistically associated with an increase in stent patency (P = 0.009; aHR = 0.27, 95%CI: 0.10-0.72). CEA levels can easily be measured at the time of stent placement and may help clinicians to predict stent patency and determine the appropriate stent procedure.

  8. Covered Balloon-Expanding Stents in Airway Stenosis.

    Science.gov (United States)

    Majid, Adnan; Kheir, Fayez; Chung, Jey; Alape, Daniel; Husta, Bryan; Oh, Scott; Folch, Erik

    2017-04-01

    The balloon-expanding stents are widely available but rarely described for use within the tracheobronchial tree. This report describes our experience with these stents in airway stenosis particularly as a lobar salvage therapy. This was a retrospective review of all records in which the balloon-expanding stents were used at a tertiary medical center. Ages, sex, location of stenosis, etiology of stenosis, stent size, duration of stent placement and associated interventions for airway stenosis were recorded. Patient's self-reported respiratory symptoms, dyspnea scale, and radiographic imaging at baseline and after stent placement were also reported. Twenty-one Atrium iCAST stents were inserted in 18 patients with malignant and benign airway disease. The median age was 69.5 years (interquartile range, 53.5 to 74). Most stents (n=20, 95%) were deployed in the lobar airways. There was a significant improvement in the modified Medical Research Council dyspnea scale from median of 3 to 2 (Pstent placement was achieved in 15 patients (83%). No deaths were related to airway stenting complications. Adverse events related to stents included migration (n=2, 9.5%), granulation tissue formation (n=2, 9.5%) and mucus plugging (n=1, 4.8%). Lobar stenting with balloon-expanding metallic stents appears feasible, safe and improves symptoms as well as radiographic atelectasis in patients with lobar airway stenosis in this small case series. Larger studies are needed to confirm this observation and to address long-term safety.

  9. Novel biliary self-expanding metal stents: indications and applications.

    Science.gov (United States)

    Blero, Daniel; Huberty, Vincent; Devière, Jacques

    2015-03-01

    Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.

  10. Design Investigation on Applicable Mesh Structures for Medical Stent Applications

    Science.gov (United States)

    Asano, Shoji; He, Jianmei

    2017-11-01

    In recent years, utilization of medical stents is one of effective treatments for stenosis and occlusion occurring in a living body’s lumen indispensable for maintenance of human life such as superficial femoral artery (SFA) occlusion. However, there are concerns about the occurrence of fatigue fractures caused by stress concentrations, neointimal hyperplasia and the like due to the shape structure and the manufacturing method in the conventional stents, and a stent having high strength and high flexibility is required. Therefore, in this research, applicable mesh structures for medical stents based on the design concepts of high strength, high flexibility are interested to solve various problem of conventional stent. According to the shape and dimensions of SFA occlusion therapy stent and indwelling delivery catheter, shape design of the meshed stent are performed using 3-dimensional CAD software Solid Works first. Then analytical examination on storage characteristics and compression characteristics of such mesh structure applied stent models were carried out through finite element analysis software ANSYS Workbench. Meshed stent models with higher strength and higher flexibility with integral molding are investigated analytically. It was found that the storage characteristics and compression characteristics of meshed stent modles are highly dependent on the basic mesh shapes with same surface void ratio. Trade-off relationship between flexibility and storage characteristics is found exited, it is required to provide appropriate curvatures during basic mesh shape design.

  11. Shrinking the Supply Chain for Implantable Coronary Stent Devices.

    Science.gov (United States)

    Moore, Sean S; O'Sullivan, Kevin J; Verdecchia, Francesco

    2016-02-01

    Stenting treatments for the management of disease in the heart, arterial and venous systems, biliary ducts, urethras, ureters, oesophageal tract and prostate have made enormous technical advances since their introduction into clinical use. The progression from metallic to polymer based bio-absorbable stents, coupled with the advances in additive manufacturing techniques, present a unique opportunity to completely re-envision the design, manufacture, and supply chain of stents. This paper looks at current stenting trends and proposes a future where the stent supply chain is condensed from ~150 days to ~20 min. The Cardiologist therefore has the opportunity to become a designer, manufacturer and user with patients receiving custom stents specific to their unique pathology that will be generated, delivered and deployed in the Cath-lab. The paper will outline this potentially revolutionary development and consider the technical challenges that will need to be overcome in order to achieve these ambitious goals. A high level overview of the generating eluting stents in situ program-GENESIS-is outlined including some early experimental work.

  12. Mechanical design of an intracranial stent for treating cerebral aneurysms.

    Science.gov (United States)

    Shobayashi, Yasuhiro; Tanoue, Tetsuya; Tateshima, Satoshi; Tanishita, Kazuo

    2010-11-01

    Endovascular treatment of cerebral aneurysms using stents has advanced markedly in recent years. Mechanically, a cerebrovascular stent must be very flexible longitudinally and have low radial stiffness. However, no study has examined the stress distribution and deformation of cerebrovascular stents using the finite element method (FEM) and experiments. Stents can have open- and closed-cell structures, and open-cell stents are used clinically in the cerebrovasculature because of their high flexibility. However, the open-cell structure confers a risk of in-stent stenosis due to protrusion of stent struts into the normal parent artery. Therefore, a flexible stent with a closed-cell structure is required. To design a clinically useful, highly flexible, closed-cell stent, one must examine the mechanical properties of the closed-cell structure. In this study, we investigated the relationship between mesh patterns and the mechanical properties of closed-cell stents. Several mesh patterns were designed and their characteristics were studied using numerical simulation. The results showed that the bending stiffness of a closed-cell stent depends on the geometric configuration of the stent cell. It decreases when the stent cell is stretched in the circumferential direction. Mechanical flexibility equal to an open-cell structure was obtained in a closed-cell structure by varying the geometric configuration of the stent cell. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul

    2011-01-01

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 ± 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  14. Mechanical Recanalization of Cerebral Artery Embolic Occlusion Using a Self-Expanding Stent: Experimental Analysis in Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Kim, Snag Joon; Lee, Deok Hee; Suh, Dae Chul [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2011-07-15

    To evaluate the feasibility of a self-expanding stent for acute embolic occlusion, and recanalization mechanism by histologic examination. Five mongrel dogs were used as study subjects. Each vertebral artery was occluded, and a self-expanding stent was used for recanalization. We evaluated the technical success rate for the placement of the stent to the targeted vessel, the recanalization rate, and residual stenosis. We obtained two specimens of the stented vertebral arteries for histologic evaluation. One dog died of an unknown cause during the induction of anesthesia. In two dogs, only one side of the vertebral artery was used, whereas both vertebral arteries were used in the remaining dogs. A total of six vertebral arteries were successfully occluded. The technical success rate for stenting without complication was 66.7%. The immediate recanalization rate after stenting was 100%. The residual stenosis was 35.6 {+-} 18.6%. On microscopic examination, the stent concentrically displaced the clot and the clot was captured between the stent mesh and arterial wall. Self-expanding stents were effective in revascularizing the cerebrovascular embolic occlusion. The self-expanding stent seemed to achieve recanalization by pushing the clot to the arterial wall and capturing the clot between the stent mesh and arterial wall.

  15. Mechanism Design and Testing of a Self-Deploying Structure Using Flexible Composite Tape Springs

    Science.gov (United States)

    Footdale, Joseph N.; Murphey, Thomas W.

    2014-01-01

    The detailed mechanical design of a novel deployable support structure that positions and tensions a membrane optic for space imagining applications is presented. This is a complex three-dimensional deployment using freely deploying rollable composite tape spring booms that become load bearing structural members at full deployment. The deployment tests successfully demonstrate a new architecture based on rolled and freely deployed composite tape spring members that achieve simultaneous deployment without mechanical synchronization. Proper design of the flexible component mounting interface and constraint systems, which were critical in achieving a functioning unit, are described. These flexible composite components have much potential for advancing the state of the art in deployable structures, but have yet to be widely adopted. This paper demonstrates the feasibility and advantages of implementing flexible composite components, including the design details on how to integrate with required traditional mechanisms.

  16. Biodegradable shape-memory block co-polymers for fast self-expandable stents.

    Science.gov (United States)

    Xue, Liang; Dai, Shiyao; Li, Zhi

    2010-11-01

    Block co-polymers PCTBVs (M(n) of 36,300-65,300 g/mol, T(m) of 39-40 and 142 degrees C) containing hyperbranched three-arm poly(epsilon-caprolactone) (PCL) as switching segment and microbial polyester PHBV as crystallizable hard segment were designed as biodegradable shape-memory polymer (SMP) for fast self-expandable stent and synthesized in 96% yield by the reaction of three-arm PCL-triol (M(n) of 4200 g/mol, T(m) of 47 degrees C) with methylene diphenyl 4,4'-diisocyanate isocynate (MDI) to form the hyperbrached MDI-linked PCL (PTCM; M(n) of 25,400 g/mol and a T(m) of 38 degrees C), followed by further polymerization with PHBV-diol (M(n) of 2200 g/mol, T(m) of 137 and 148 degrees C). The polymers were characterized by (1)H NMR, GPC, DSC, tensile test, and cyclic thermomechanical tensile test. PCTBVs showed desired thermal properties, mechanical properties, and ductile nature. PCTBV containing 25 wt% PHBV (PCTBV-25) demonstrated excellent shape-memory property at 40 degrees C, with R(f) of 94%, R(r) of 98%, and shape recovery within 25s. PCTBV-25 was also shown as a safe material with good biocompatibility by cytotoxicity tests and cell growth experiments. The stent made from PCTBV-25 film showed nearly complete self-expansion at 37 degrees C within only 25 s, which is much better and faster than the best known self-expandable stents. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  17. Complications related to conventional self-expandable metal stent insertion and internal irradiation stent insertion in patients with advanced esophageal carcinoma: an analysis of 32 cases

    International Nuclear Information System (INIS)

    Xu Xingwen; Di Haiting; Zhu Jun; Shi Jian

    2011-01-01

    Objective: To compare the occurrence of complications between conventional self-expandable metal stent and internal irradiation stent insertion in treating patients with advanced esophageal carcinomas. Methods: A total of 32 patients with advanced esophageal carcinoma were randomly divided into irradiation stent group (n=15) and conventional stent group (n=17). Internal irradiation stent loaded with 125 I seeds was employed in patients of irradiation stent group, while conventional self-expandable metal stent was used in patients of conventional stent group. After the treatment, clinical follow-up was regularly conducted. Postoperative complications such as fever, severe chest pain, cough, esophageal perforation, pneumonia, hemorrhage, stent migration and restenosis, etc. were observed. Results: No significant difference in the occurrence of fever, severe chest pain, esophageal perforation and hemorrhage existed between the two groups (P>0.05). The difference in the occurrence of long-term complications such as stent migration or restenosis between the two groups was out statistically significant (P>0.05). However, the restenosis in irradiation stent group occurred obviously much later than that in conventional stent group. Conclusion: For the treatment of advanced esophageal carcinomas, the insertion of internal irradiation esophageal stent is safe. It dose not increase the incidence of postoperative complications. Therefore, it is worth popularizing this technique in clinical practice. (authors)

  18. Covered Metal Stenting for Malignant Lower Biliary Stricture with Pancreatic Duct Obstruction: Is Endoscopic Sphincterotomy Needed?

    Directory of Open Access Journals (Sweden)

    Kazunari Nakahara

    2013-01-01

    Full Text Available Aims. To evaluate the need for endoscopic sphincterotomy (EST before covered self-expandable metal stent (CSEMS deployment for malignant lower biliary stricture with pancreatic duct obstruction. Methods. This study included 79 patients who underwent CSEMS deployment for unresectable malignant lower biliary stricture with pancreatic duct obstruction. Treatment outcomes and complications were compared between 38 patients with EST before CSEMS deployment (EST group and 41 without EST (non-EST group. Results. The technical success rates were 100% in both the EST and the non-EST group. The incidence of pancreatitis was 2.6% in the EST, and 2.4% in the non-EST group (. The incidences of overall complications were 18.4% and 14.6%, respectively, (. Within the non-EST groups, the incidence of pancreatitis was 0% in patients with fully covered stent deployment and 3.6% in those with partially covered stent deployment (. In the multivariate analysis, younger age (, OR 12 and nonpancreatic cancer (, OR 24 were significant risk factors for overall complications after CSEMS deployment. EST was not identified as a risk factor. Conclusions. EST did not reduce the incidence of pancreatitis after CSEMS deployment in patients of unresectable distal malignant obstruction with pancreatic duct obstruction.

  19. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases

    NARCIS (Netherlands)

    van Halsema, Emo E.; Wong Kee Song, Louis M.; Baron, Todd H.; Siersema, Peter D.; Vleggaar, Frank P.; Ginsberg, Gregory G.; Shah, Pari M.; Fleischer, David E.; Ratuapli, Shiva K.; Fockens, Paul; Dijkgraaf, Marcel G. W.; Rando, Giacomo; Repici, Alessandro; van Hooft, Jeanin E.

    2013-01-01

    Temporary placement of self-expandable stents has been increasingly used for the management of benign esophageal diseases. To evaluate the safety of endoscopic removal of esophageal self-expandable stents placed for the treatment of benign esophageal diseases. Multicenter retrospective study. Six

  20. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

    Energy Technology Data Exchange (ETDEWEB)

    Løvdal, Alexandra Liv Vest, E-mail: alvlo@nanotech.dtu.dk [Technical University of Denmark, Department of Micro- and Nanotechnology (Denmark); Calve, Sarah [Purdue University, Weldon School of Biomedical Engineering (United States); Yang, Shuo; Alstine, William Van [Cook Research Incorporated (United States); Binkert, Christoph A. [Institut für Radiologie, Kantonsspital Winterthur (Switzerland); Klausen, Kasper [William Cook Europe (Denmark)

    2017-01-15

    PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  1. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(L-lactide) In Vitro and In Vivo.

    Science.gov (United States)

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo; Van Alstine, William; Binkert, Christoph A; Klausen, Kasper

    2017-01-01

    This study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo. A diamond-shaped stent-base was cut from a sequential biaxially strained poly(L-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively. In vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks. A bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  2. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

    International Nuclear Information System (INIS)

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo; Alstine, William Van; Binkert, Christoph A.; Klausen, Kasper

    2017-01-01

    PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

  3. Design and modeling balloon-expandable coronary stent for manufacturability

    Science.gov (United States)

    Suryawan, D.; Suyitno

    2017-02-01

    Coronary artery disease (CAD) is a disease that caused by narrowing of the coronary artery. The narrowing coronary artery is usually caused by cholesterol-containing deposit (plaque) which can cause a heart attack. CAD is the most common cause mortality in Indonesia. The commonly CAD treatment use the stent to opens or alleviate the narrowing coronary artery. In this study, the stent design is optimized for the manufacturability. Modeling is used to determine the free stent expansion due to applied pressure in the inner surface of the stent. The stress distribution, outer diameter change, and dogboning phenomena are investigated in the simulation. The result of modeling and simulating was analyzed and used to optimize the stent design before it is manufactured using EDM (Electric Discharge Machine) in the next research.

  4. Self-Expandable Metallic Stent for the Palliative Treatment of Obstructing Left-Sided Colorectal Cancer under Fluoroscopic Guidance: A Comparison of the Clinical Results according to Stent Diameter

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Pyeong Guk; Hong, Hyun Pyo; Choi, Yoon Jung; Lee, Min Hee; Park, Hae Won; Chung, Eun Chul [Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2010-03-15

    To evaluate the feasibility, effectiveness, and safety of self-expandable metallic stent for the palliative treatment of obstructing left-sided colorectal cancer under fluoroscopic guidance, and to compare results according to the stent diameter. Under fluoroscopic guidance, 31 self-expandable metallic stents were placed into 25 patients for palliative purposes. The rates of technical success, clinical success, complications associated with stent insertion, patient survival, and primary stent patency were evaluated. The results were also compared between two groups: 13 patients using stents with a diameter of 22 mm and 12 patients using stents with a diameter of 26 mm. The technical and clinical success rates were 93.5 and 90.3%, respectively. The complications included severe abdominal pain (6.5%), minor rectal bleeding (9.7%), stent migration (9.7%), and tumor ingrowth or overgrowth (9.7%). No statistical differences in technical were detected between the two groups for the clinical success rate and complication rates. The mean survival time was 5.5 +- 1.4 months. The primary stent patency rates were 91.3% at 5 months, 85.2% at 10 months, and 77.4% at 15 months. The mean period of stent patency was 12.4 +- 2.6 months. The mean period of primary stent patency was 16.4 +- 2.6 months in the 26 mm stent group, and significantly higher than 5.4 +- 1.4 months in the 22 mm stent group (p=0.031). A self-expandable metallic stent under fluoroscopic guidance, for the palliative treatment of obstructing left-sided colorectal cancer, was feasible and effective, and yielded good clinical results. The period of primary stent patency of the 26 mm stent group was longer than the 22 mm stent group, and the complication rate was not significantly different between the two stent groups

  5. Self-Expandable Metallic Stent for the Palliative Treatment of Obstructing Left-Sided Colorectal Cancer under Fluoroscopic Guidance: A Comparison of the Clinical Results according to Stent Diameter

    International Nuclear Information System (INIS)

    Kang, Pyeong Guk; Hong, Hyun Pyo; Choi, Yoon Jung; Lee, Min Hee; Park, Hae Won; Chung, Eun Chul; Kim, Sam Soo

    2010-01-01

    To evaluate the feasibility, effectiveness, and safety of self-expandable metallic stent for the palliative treatment of obstructing left-sided colorectal cancer under fluoroscopic guidance, and to compare results according to the stent diameter. Under fluoroscopic guidance, 31 self-expandable metallic stents were placed into 25 patients for palliative purposes. The rates of technical success, clinical success, complications associated with stent insertion, patient survival, and primary stent patency were evaluated. The results were also compared between two groups: 13 patients using stents with a diameter of 22 mm and 12 patients using stents with a diameter of 26 mm. The technical and clinical success rates were 93.5 and 90.3%, respectively. The complications included severe abdominal pain (6.5%), minor rectal bleeding (9.7%), stent migration (9.7%), and tumor ingrowth or overgrowth (9.7%). No statistical differences in technical were detected between the two groups for the clinical success rate and complication rates. The mean survival time was 5.5 ± 1.4 months. The primary stent patency rates were 91.3% at 5 months, 85.2% at 10 months, and 77.4% at 15 months. The mean period of stent patency was 12.4 ± 2.6 months. The mean period of primary stent patency was 16.4 ± 2.6 months in the 26 mm stent group, and significantly higher than 5.4 ± 1.4 months in the 22 mm stent group (p=0.031). A self-expandable metallic stent under fluoroscopic guidance, for the palliative treatment of obstructing left-sided colorectal cancer, was feasible and effective, and yielded good clinical results. The period of primary stent patency of the 26 mm stent group was longer than the 22 mm stent group, and the complication rate was not significantly different between the two stent groups

  6. Comparison of closed-cell and hybrid-cell stent designs in carotid artery stenting: clinical and procedural outcomes

    Directory of Open Access Journals (Sweden)

    Ersan TatlI

    2017-05-01

    Full Text Available Introduction: Carotid artery stenting (CAS is a promising alternative to surgery in high-risk patients. However, the impact of stent cell design on outcomes in CAS is a matter of continued debate. Aim : To compare the periprocedural and clinical outcomes of different stent designs for CAS with distal protection devices. Material and methods : All CAS procedures with both closed- and hybrid-cell stents performed at our institution between February 2010 and December 2015 were analyzed retrospectively. Adverse events were defined as death, major stroke, minor stroke, transient ischemic attack and myocardial infarction. Periprocedural and 30-day adverse events and internal carotid artery (ICA vasospasm rates were compared between the closed-cell and hybrid-cell stent groups. Results : The study included 234 patients comprising 146 patients with a closed-cell stent (Xact stent, Abbott Vascular (mean age: 68.5 ±8.6; 67.1% male and 88 patients with a hybrid-cell stent (Cristallo Ideale, Medtronic (mean age: 67.2 ±12.8; 68.2% male. There was no significant difference between the groups with respect to periprocedural or 30-day adverse event rates. While there was no difference in terms of tortuosity index between the groups, there was a higher procedural ICA vasospasm rate in the closed-cell stent group (35 patients, 23% compared with the hybrid-cell stent group (10 patients, 11% (p = 0.017. Conclusions : The results of this study showed no significant difference in the clinical adverse event rates after CAS between the closed-cell stent group and the hybrid-cell stent group. However, procedural ICA vasospasm was more common in the closed-cell stent group.

  7. Self-expandable metalic endotracheal stent

    International Nuclear Information System (INIS)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author)

  8. Self-expandable metalic endotracheal stent

    Energy Technology Data Exchange (ETDEWEB)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author).

  9. Feasibility of Angioplasty and Stenting for Abdominal Aortic Lesions Adjacent to Previously Stented Visceral Artery Lesions in Patients with Takayasu Arteritis

    International Nuclear Information System (INIS)

    Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas

    2007-01-01

    Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis

  10. [The application of Y-shaped self-expandable covered metal stents in the thoracostomach-airway fistula: a single center, 11 years experience].

    Science.gov (United States)

    Fang, Yi; Li, Tengfei; Han, Xinwei; Wu, Gang; Ren, Jianzhuang; Ren, Kewei; Lu, Huibin; Zhang, Quanhui; Li, Zongming

    2015-08-01

    To investigate the clinical feasibility and efficacy of Y-shaped self-expandable covered metal stents (Y-stents) in the management of thoracostomach-airway fistula. Retrospective analysis was performed for 108 patients treated for thoracostomach-airway fistula with Y-shaped self-expandable coated metal stents between April 2003 and October 2014. Y-stents were designed based on the dimensions of trachea and bronchus and sites of the fistula and then were inserted under DSA monitoring. There were 65 cases with single big Y-stent placement, 26 cases with single small Y-stent placement, 23 cases with double Y-stents placement, and 1 case with 3 Y-stents placement. Stent implantation was successfully accomplished with single manipulation in all patients. Complete occlusion of the fistula was obtained in 104 patients after the primary manipulation, and 4 patients required a secondary manipulation where a double Y-stents was inserted because of failure of primary manipulate. Ninety-two patients completed the follow-up , while 16 were lost. Fifty-nine patients died while 33 were alive with marked improvement in their quality of life. The placement of Y-stents can effectively occlude the thoracostomach-airway fistula in patients who had had the esophageal tumors resected. The technique is not only feasible but reliable to improve the quality of life of the patients.

  11. Use of retrievable self-expanding stent in treating childhood benign oesophageal stricture

    International Nuclear Information System (INIS)

    Yu Juming; Fan Guoping; Zhong Weixing; Zhu Ming

    2007-01-01

    Objective: To evaluate the methods and effect of retrievable self-expanding esophageal stent in treating benign esophageal stenosis of children. Methods: The covered retrievable expandable nitinol stents were placed in 10 children with corrosive esophageal stenosis and post-anastomotic stenosis, age ranged from 2 to 12 years, the dysphagia scores were 3, Barium esophagography was taken before the use of retrievable stent. Results: The stents were placed safely in all patients without complications and were successfully removed after all. After the stent placement, all patients could take solid food without dysphagia. During 6 to 12 months follow-up after the stent removal, all children could eat satisfactorily with the dysphagia score as 0. Conclusion: The use of covered retrievable expandable stent is effective and safe in treating childhood benign esophageal stenosis. (authors)

  12. Transnasal tracheobronchial stenting for malignant airway narrowing under local anesthesia: Our experience of treating three cases using this technique

    International Nuclear Information System (INIS)

    Medhi, Jayanta; Handique, Akash; Goyal, Amit; Lynser, Donbok; Phukan, Pranjal; Sarma, Kalyan; Padmanabhan, Aswin; Saikia, Manuj Kumar; Chutia, Happy

    2016-01-01

    To study the technical feasibility of tracheobronchial stenting via transnasal route under bronchoscopy and fluoroscopic guidance in severe malignant airway strictures using self-expandable nitinol stents. We describe three patients with malignant airway strictures, treated entirely via transnasal route under local anesthesia using bronchoscopic and fluoroscopic guidance. Nasal route allowed convenient access to the airway for the bronchoscope across the stricture and a guidewire was introduced through its working channel. The 18F tracheal stent and the 6F bronchial stent assembly could be easily introduced and deployed under bronchoscopic (reintroduced through the other nostril) and fluoroscopic guidance. We achieved technical success in all the three patients with immediate relief of dyspnea. Transnasal airway stenting with self-expandable nitinol stent using bronchoscopic and fluoroscopic guidance under local anesthesia is a safe and effective method with minimal patient discomfort

  13. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-07-01

    Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.

  14. Finite element analyses for design evaluation of biodegradable magnesium alloy stents in arterial vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wu Wei [Laboratory of Biological Structure Mechanics, Structural Engineering Department, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan (Italy); Gastaldi, Dario, E-mail: dario.gastaldi@polimi.it [Laboratory of Biological Structure Mechanics, Structural Engineering Department, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan (Italy); Yang Ke; Tan Lili [Division of Specialized Materials and Devices, Institute of Metal Research, Chinese Academy of Sciences, Shenyang (China); Petrini, Lorenza; Migliavacca, Francesco [Laboratory of Biological Structure Mechanics, Structural Engineering Department, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan (Italy)

    2011-12-15

    Biodegradable magnesium alloy stents (MAS) can provide a great benefit for diseased vessels and avoid the long-term incompatible interactions between vessels and permanent stent platforms. However, the existing MAS showed insufficient scaffolding to the target vessels due to short degradation time. In this study, a three dimensional finite element model combined with a degradable material model of AZ31 (Al 0.03, Zn 0.01, Mn 0.002 and Mg balance, mass percentage) was applied to three different MAS designs including an already implanted stent (Stent A), an optimized design (Stent B) and a patented stent design (Stent C). One ring of each design was implanted through a simulation in a vessel model then degraded with the changing interaction between outer stent surface and the vessel. Results showed that a proper stent design (Stent B) can lead to an increase of nearly 120% in half normalized recoil time of the vessel compared to the Stent A; moreover, the expectation that the MAS design, with more mass and optimized mechanical properties, can increase scaffolding time was verified numerically. The Stent C has more materials than Stent B; however, it only increased the half normalized recoil time of the vessel by nearly 50% compared to the Stent A because of much higher stress concentration than that of Stent B. The 3D model can provide a convenient design and testing tool for novel magnesium alloy stents.

  15. Finite element analyses for design evaluation of biodegradable magnesium alloy stents in arterial vessels

    International Nuclear Information System (INIS)

    Wu Wei; Gastaldi, Dario; Yang Ke; Tan Lili; Petrini, Lorenza; Migliavacca, Francesco

    2011-01-01

    Biodegradable magnesium alloy stents (MAS) can provide a great benefit for diseased vessels and avoid the long-term incompatible interactions between vessels and permanent stent platforms. However, the existing MAS showed insufficient scaffolding to the target vessels due to short degradation time. In this study, a three dimensional finite element model combined with a degradable material model of AZ31 (Al 0.03, Zn 0.01, Mn 0.002 and Mg balance, mass percentage) was applied to three different MAS designs including an already implanted stent (Stent A), an optimized design (Stent B) and a patented stent design (Stent C). One ring of each design was implanted through a simulation in a vessel model then degraded with the changing interaction between outer stent surface and the vessel. Results showed that a proper stent design (Stent B) can lead to an increase of nearly 120% in half normalized recoil time of the vessel compared to the Stent A; moreover, the expectation that the MAS design, with more mass and optimized mechanical properties, can increase scaffolding time was verified numerically. The Stent C has more materials than Stent B; however, it only increased the half normalized recoil time of the vessel by nearly 50% compared to the Stent A because of much higher stress concentration than that of Stent B. The 3D model can provide a convenient design and testing tool for novel magnesium alloy stents.

  16. Long-term results of percutaneous self-expandable metallic stents in malignant biliary obstruction

    International Nuclear Information System (INIS)

    Kobashi, Yuko; Hoshikawa, Yoshikazu

    2004-01-01

    Evaluation of the long-term follow-up data of 155 patients with inoperable malignant biliary obstruction who received percutaneous placement of self expandable metallic stent (EMS) and external beam radiotherapy (EBR) combined with self-expandable metallic stent. One-hundred sixty EMS were inserted in 155 patients with inoperable malignant biliary obstruction. One-hundred forty-three patients (Group A) were inserted EMS alone. Twelve patients (Group B) underwent external radiotherapy (40∼45 Gy) after stent insertion. We compared to the Group A and Group B about survival, stent patency and administration. The mean length of survival for the entire group was 111±87 days, while the mean period of patency for all stents was 103±74. We found no statistically significant difference in patient survival or stent patency periods in regard to the level and cause of obstruction. Prolongation of actuarial survival was observed in Group B (316±231 days) as compared to Group A (126±85 days,). Mean length of survival rate and mean period of stent patency rate were not significantly different in regard to the level, cause of obstruction and each stent. External radiotherapy combined EMS could achieve effective palliation and improve the quality of life in selected patients with malignant biliary obstruction. (author)

  17. Self-expandable metal stents for obstructing colonic and extracolonic cancer

    DEFF Research Database (Denmark)

    van Hooft, Jeanin E; van Halsema, Emo E; Vanbiervliet, Geoffroy

    2014-01-01

    as a bridge to elective surgery is not recommended as a standard treatment of symptomatic left-sided malignant colonic obstruction (strong recommendation, high quality evidence). 3 For patients with potentially curable but obstructing left-sided colonic cancer, stent placement may be considered......, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations The following recommendations should only be applied after a thorough diagnostic evaluation including a contrast-enhanced computed tomography (CT) scan. 1 Prophylactic colonic...... stent placement is not recommended. Colonic stenting should be reserved for patients with clinical symptoms and imaging evidence of malignant large-bowel obstruction, without signs of perforation (strong recommendation, low quality evidence). 2 Colonic self-expandable metal stent (SEMS) placement...

  18. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  19. Self-expanding intracoronary stents in the treatment of coronary artery disease: new developments and future directions

    NARCIS (Netherlands)

    Lu, H.; Grundeken, M. J.; Koch, K. T.; Wykrzykowska, J. J.

    2013-01-01

    The first stent implanted in the human coronary circulation was a self-expandable (SE) stent and was introduced almost simultaneously with the first balloon-expandable (BE) stents in the late 1980s. Nowadays, the majority of the available stents are delivered by balloon expansion. While BE stents

  20. Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.

    Science.gov (United States)

    Kim, Gi Beom; Lim, Hong-Gook; Kim, Yong Jin; Choi, Eun Young; Kwon, Bo Sang; Jeong, Saeromi

    2014-04-15

    Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. We made a nitinol-wire-based, self-expandable valved stent with leaflets made from porcine pericardium. The porcine pericardium was treated with α-galactosidase, glutaraldehyde, and glycine after decellularization. After cutting the inguinal or cervical area, we implanted a valved stent in 12 sheep through the femoral or jugular vein by using an 18-Fr delivery catheter, controlling the catheter handles and hook block under fluoroscopic and echocardiographic guidance. The mean body weight of sheep was 43.9 kg. We successfully implanted valved stents (diameter: 24 mm in 7 sheep, 26 mm in 5 sheep) in good position in 8 sheep, in the main pulmonary artery (PA) in 2 sheep, and in the right ventricular outlet tract (RVOT) in 2 sheep. We sacrificed 8 sheep (6 sheep in good position, 1 sheep in the main PA, and 1 sheep in the RVOT) after >6 months. Five of the 6 sheep implanted in good position showed well-preserved valve morphology at the time of sacrifice. Histologic findings after routine sacrifice showed well-maintained collagen wave structure and no visible calcification in all explanted valve leaflets. Transcatheter implantation of a nitinol-wire-based, self-expandable valved stent in the pulmonic valve was feasible, and stents implanted in good position showed well-preserved valve leaflets with functional competence in the mid-term results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Stent underexpansion in angiographic guided percutaneous coronary intervention, despite adjunctive balloon post-dilatation, in drug eluting stent era

    Directory of Open Access Journals (Sweden)

    Mehrdad Taherioun

    2014-01-01

    Full Text Available BACKGROUND: Stent underexpansion is the most powerful predictor of long-term stent patency and clinical outcome. The purpose of this study was to evaluate the incidence and predictors of stent underexpansion despite adjunctive post-dilatation with non-compliant balloon. METHODS: After elective coronary stent implantation and adjunctive post-dilatation with non-compliant balloon and optimal angiographic result confirmed by the operator, intravascular ultrasound (IVUS was performed for all the treated lesions. If the treated lesions fulfilled the IVUS criteria, they are considered as the optimal stent group; if not, they are considered as the suboptimal group. RESULTS: From 50 patients enrolled in this study 39 (78% had optimal stent deployment and 11 (22% had suboptimal stent deployment. In the suboptimal group 7 (14% had underexpansion, 2 (4% malposition, and 2 (4% had asymmetry. There were no stent edge dissections detected by IVUS. We did not find any correlation between lesion calcification, ostial lesions, stent length, and stent underexpansion. Stent diameter ≤ 2.75 mm had a strong correlation with stent underexpansion. CONCLUSION: Despite adjunctive post-dilatation with noncompliant balloon, using a relatively small stent diameter was a strong predictor for underexpansion. IVUS guided percutaneous coronary intervention (PCI may be considered for drug eluting stent (DES implantation in relatively small vessels.   Keywords: Stent, Percutaneous Coronary Intervention, Ultrasound, Post-dilatation 

  2. Self-expanding oesophageal metal stents for the palliation of dysphagia due to extrinsic compression

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, N.K.; Boylan, C.E.; Razzaq, R.; England, R.E.; Mirra, L.; Martin, D.F. [Dept. of Radiology, South Manchester University Hospitals NHS Trust, Withington Hospital (United Kingdom)

    1999-07-01

    The role of self-expanding metallic stents is well established in the palliation of oesophageal stenosis and dysphagia due to primary oesophageal malignancy. However, their role in palliation of dysphagia due to external compressive mediastinal malignancies is not well established. The purpose of this study was to assess the efficacy of self-expanding metallic stents in the palliation of dysphagia due to extrinsic oesophageal compression by mediastinal malignancy. Between January 1995 and January 1998, 21 patients with oesophageal compression due to malignant mediastinal tumours underwent oesophageal stent placement for palliation of dysphagia. Complete data were available in 17 patients (10 men and 7 women). The mean age was 63.5 years (range 46-89 years). A total of 19 stents were placed successfully. The dysphagia grade prior to and after oesophageal stent placement was assessed and the complications documented. Of the 17 patients, 16 reported an improvement in dysphagia. The mean dysphagia score improved from 3.1 prior to treatment to 1.3 after treatment. In 1 patient the stent slipped during placement and another stent was placed satisfactorily. Early complications (within 48 h) in the form of mild to moderate retrosternal chest pain occurred in 5 patients. This was treated symptomatically. Late complications (after 48 h) in the form of bolus impaction occurred in 2 patients. This was successfully treated with oesophagoscopy and removal of bolus. In 2 patients the stent was overgrown by tumour and in one of these an additional stent was placed. In 1 patient incomplete closure of a tracheo-oesophageal fistula was observed. There was no procedure- or stent-related mortality. The mean survival time of this group was 2.1 months. Self-expanding metallic stents can be safely and effectively used in the palliation of dysphagia due to external mediastinal malignancies. (orig.)

  3. Self-expanding oesophageal metal stents for the palliation of dysphagia due to extrinsic compression

    International Nuclear Information System (INIS)

    Gupta, N.K.; Boylan, C.E.; Razzaq, R.; England, R.E.; Mirra, L.; Martin, D.F.

    1999-01-01

    The role of self-expanding metallic stents is well established in the palliation of oesophageal stenosis and dysphagia due to primary oesophageal malignancy. However, their role in palliation of dysphagia due to external compressive mediastinal malignancies is not well established. The purpose of this study was to assess the efficacy of self-expanding metallic stents in the palliation of dysphagia due to extrinsic oesophageal compression by mediastinal malignancy. Between January 1995 and January 1998, 21 patients with oesophageal compression due to malignant mediastinal tumours underwent oesophageal stent placement for palliation of dysphagia. Complete data were available in 17 patients (10 men and 7 women). The mean age was 63.5 years (range 46-89 years). A total of 19 stents were placed successfully. The dysphagia grade prior to and after oesophageal stent placement was assessed and the complications documented. Of the 17 patients, 16 reported an improvement in dysphagia. The mean dysphagia score improved from 3.1 prior to treatment to 1.3 after treatment. In 1 patient the stent slipped during placement and another stent was placed satisfactorily. Early complications (within 48 h) in the form of mild to moderate retrosternal chest pain occurred in 5 patients. This was treated symptomatically. Late complications (after 48 h) in the form of bolus impaction occurred in 2 patients. This was successfully treated with oesophagoscopy and removal of bolus. In 2 patients the stent was overgrown by tumour and in one of these an additional stent was placed. In 1 patient incomplete closure of a tracheo-oesophageal fistula was observed. There was no procedure- or stent-related mortality. The mean survival time of this group was 2.1 months. Self-expanding metallic stents can be safely and effectively used in the palliation of dysphagia due to external mediastinal malignancies. (orig.)

  4. Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2014-01-01

    Full Text Available Tracheal penetration of esophageal self-expanding metallic stents (SEMS with/without tracheoesophageal fistula (TEF formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breathing difficulty and aspiration following third esophageal stent placement, tracheal erosion and TEF formation due to the tracheal penetration by esophageal stent were diagnosed. The patient was successfully managed by covered tracheal SEMS placement under flexible bronchoscopy.

  5. Chest pain following oesophageal stenting for malignant dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Golder, Mark; Tekkis, Paris P.; Kennedy, Colette; Lath, Sadaf; Toye, Rosemary; Steger, Adrian C

    2001-03-01

    AIM: The palliative use of self-expanding metallic stents has been widely reported to relieve dysphagia in cases of oesophageal carcinoma. Little has been documented on the severity of chest pain following oesophageal stenting. The aim of this study was to investigate the association of pain with oesophageal stenting for malignant dysphagia. METHODS: Fifty-two patients with inoperable oesophageal carcinoma underwent stent placement between 1995-1999. Daily opioid analgesic requirements (mg of morphine equivalent doses) were monitored for 3 days before and 7 days after stenting. The degree of palliation was expressed as a dysphagia score (0-3). Hospital stay, readmission days, stent complications and patient survival time were also recorded. RESULTS: Twenty-six patients (50%) required opioid analgesia for chest pain (median dose: 80 mg morphine/day) within 48 h of the procedure compared to 11 (21.2%) patients before stenting (P = 0.0041). A significant increase was evident in the analgesic consumption following stent deployment (P < 0.001). The dysphagia score improved by a median value of 1 (CI 0.25)P < 0.001, with a re-intervention rate of 11.5%. The median survival time was 40 days post stenting (range 1-120). CONCLUSION: A significant proportion of patients developed chest pain after oesophageal stenting, requiring high dose opioid analgesia. As the origin of the pain is still unknown, pre-emptive analgesia may a play role in reducing stent-related morbidity and possibly in-hospital stay. Golder, M. et al. (2001)

  6. Chest pain following oesophageal stenting for malignant dysphagia

    International Nuclear Information System (INIS)

    Golder, Mark; Tekkis, Paris P.; Kennedy, Colette; Lath, Sadaf; Toye, Rosemary; Steger, Adrian C.

    2001-01-01

    AIM: The palliative use of self-expanding metallic stents has been widely reported to relieve dysphagia in cases of oesophageal carcinoma. Little has been documented on the severity of chest pain following oesophageal stenting. The aim of this study was to investigate the association of pain with oesophageal stenting for malignant dysphagia. METHODS: Fifty-two patients with inoperable oesophageal carcinoma underwent stent placement between 1995-1999. Daily opioid analgesic requirements (mg of morphine equivalent doses) were monitored for 3 days before and 7 days after stenting. The degree of palliation was expressed as a dysphagia score (0-3). Hospital stay, readmission days, stent complications and patient survival time were also recorded. RESULTS: Twenty-six patients (50%) required opioid analgesia for chest pain (median dose: 80 mg morphine/day) within 48 h of the procedure compared to 11 (21.2%) patients before stenting (P = 0.0041). A significant increase was evident in the analgesic consumption following stent deployment (P < 0.001). The dysphagia score improved by a median value of 1 (CI 0.25)P < 0.001, with a re-intervention rate of 11.5%. The median survival time was 40 days post stenting (range 1-120). CONCLUSION: A significant proportion of patients developed chest pain after oesophageal stenting, requiring high dose opioid analgesia. As the origin of the pain is still unknown, pre-emptive analgesia may a play role in reducing stent-related morbidity and possibly in-hospital stay. Golder, M. et al. (2001)

  7. Reproducibility of haemodynamical simulations in a subject-specific stented aneurysm model--a report on the Virtual Intracranial Stenting Challenge 2007.

    Science.gov (United States)

    Radaelli, A G; Augsburger, L; Cebral, J R; Ohta, M; Rüfenacht, D A; Balossino, R; Benndorf, G; Hose, D R; Marzo, A; Metcalfe, R; Mortier, P; Mut, F; Reymond, P; Socci, L; Verhegghe, B; Frangi, A F

    2008-07-19

    This paper presents the results of the Virtual Intracranial Stenting Challenge (VISC) 2007, an international initiative whose aim was to establish the reproducibility of state-of-the-art haemodynamical simulation techniques in subject-specific stented models of intracranial aneurysms (IAs). IAs are pathological dilatations of the cerebral artery walls, which are associated with high mortality and morbidity rates due to subarachnoid haemorrhage following rupture. The deployment of a stent as flow diverter has recently been indicated as a promising treatment option, which has the potential to protect the aneurysm by reducing the action of haemodynamical forces and facilitating aneurysm thrombosis. The direct assessment of changes in aneurysm haemodynamics after stent deployment is hampered by limitations in existing imaging techniques and currently requires resorting to numerical simulations. Numerical simulations also have the potential to assist in the personalized selection of an optimal stent design prior to intervention. However, from the current literature it is difficult to assess the level of technological advancement and the reproducibility of haemodynamical predictions in stented patient-specific models. The VISC 2007 initiative engaged in the development of a multicentre-controlled benchmark to analyse differences induced by diverse grid generation and computational fluid dynamics (CFD) technologies. The challenge also represented an opportunity to provide a survey of available technologies currently adopted by international teams from both academic and industrial institutions for constructing computational models of stented aneurysms. The results demonstrate the ability of current strategies in consistently quantifying the performance of three commercial intracranial stents, and contribute to reinforce the confidence in haemodynamical simulation, thus taking a step forward towards the introduction of simulation tools to support diagnostics and

  8. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    International Nuclear Information System (INIS)

    Han, Young-Min; Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho

    2007-01-01

    We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates

  9. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young-Min; Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho [Chonbuk National University Medical School and Hospital, Chonju (Korea, Republic of)

    2007-10-15

    We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates.

  10. An experimental study on the influence of new spiral stent(Hanaro) on the vascular structures

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Chung, Jin Wook; Jeong, Yoong Ki; Kook, Myeong Cherl; Seo, Jung Wook [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of); Lim, Myung Kwan [Inha Univ. College of Medicine, Incheon (Korea, Republic of)

    1996-06-01

    The purpose of this study was to evaluate basic experimental data for the clinical application of a self-expandable stainless steel intravascular Hanaro spiral stent. For evaluation of the physical properties of the Hanaro stent, hoop strength, radioopacity, longitudinal flexibility, and foreshortening were measured. Twelve intravascular hanaro spiral stents were placed in the infrarenal abdominal aorta (n=6) and common iliac artery (n=6) in six mongrel dogs. Angiography and light microscopic examination were performed after one, two and eight months of placement of the stents. The stent had good radioopacity and was deployed with minimal foreshortening. hoop strength of a 6 mm-interval bend was found to be superior to that of 8 mm- and 10 mm-bend stent. On angiography the patency rate and thrombosis rate were 100% and 0% in the abdominal aorta and 50% in the common iliac artery, respectively. Minimal corrosion was seen in all stents, and they appeared to be biocompatible. The stent wires were covered with well-developed neointima which after one month had mostly fibroblast and collagen tissue ; the thickness of the neointima increased gradually during a period of eight months. At the end of that period, collagen fibres in the neointima were denser and showed a more paralled configuration than at one month. The Hanaro stent has good physical properties and also has a high patency rate, and good biocompatibilities. The stent may therefore be reliably and safely deployed in the human vascular system.

  11. Transnasal tracheobronchial stenting for malignant airway narrowing under local anesthesia: Our experience of treating three cases using this technique

    Directory of Open Access Journals (Sweden)

    Jayanta Medhi

    2016-01-01

    Full Text Available Purpose: To study the technical feasibility of tracheobronchial stenting via transnasal route under bronchoscopy and fluoroscopic guidance in severe malignant airway strictures using self-expandable nitinol stents. Materials and Methods: We describe three patients with malignant airway strictures, treated entirely via transnasal route under local anesthesia using bronchoscopic and fluoroscopic guidance. Nasal route allowed convenient access to the airway for the bronchoscope across the stricture and a guidewire was introduced through its working channel. The 18F tracheal stent and the 6F bronchial stent assembly could be easily introduced and deployed under bronchoscopic (reintroduced through the other nostril and fluoroscopic guidance. Results: We achieved technical success in all the three patients with immediate relief of dyspnea. Conclusion: Transnasal airway stenting with self-expandable nitinol stent using bronchoscopic and fluoroscopic guidance under local anesthesia is a safe and effective method with minimal patient discomfort.

  12. Vascular Biocompatibility of a Triple Layered Self Expanding Stent-Graft in a Dog Mode

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Ik; Won, Je Hwan; Jang, Eun Ho; Lee, Sung Yeong; Ko, Kwang Tae [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Jin, Bo Hwan [Medical Science Research Center, Ajou University School of Medicine, Suwon (Korea, Republic of); Lee, June Woo [Dept. of Radiology, Busan National University College of Medicine, Busan (Korea, Republic of)

    2012-02-15

    To evaluate performance and biocompatibility of a newly designed self-expanding stent graft, which consisted of two nitinol stents and an intervening expanded polytetrafluoroethylene membrane in a dog artery model. Twelve stent grafts were placed in the aorta of 6 dogs (beagle, mean body weight 11 kg) for 4 weeks (n = 4) and 12 weeks (n = 8). Luminal diameters were measured for each segment (the proximal bare, the middle graft, the distal bare) by angiographies after implantation and follow up periods. Percent luminal stenosis based on angiographies, histomorphometric, histologic, and scanning electron microscopic analyses of each segments were performed. Blood flow through the stent grafts was good after implantation and during the follow up period, without thrombotic occlusion or stent graft migration. The mean percent luminal stenosis of the proximal bare, the middle grafted and the distal bare segments after 12 weeks were 13.5%, 3.9%, 9.6% retrospectively. The mean neointimal areas of the middle grafted segment were 4.39 mm{sup 2} (4 week) and 4.92 mm{sup 2} (12 week). Mature endothelialization was evident in over 70% of the area of the stented artery after 4 weeks and in over 90% after 12 weeks. The stent graft was well placed in the attempted area without migration. During the 12-week-follow up period, it showed a good patency without thrombotic occlusion or significant in-stent luminal stenosis. Endothelialization was rapid and nearly complete. Neointima was thin and smooth on the middle graft segment and thicker and irregular on the bare segments.

  13. Vascular Biocompatibility of a Triple Layered Self Expanding Stent-Graft in a Dog Mode

    International Nuclear Information System (INIS)

    Bae, Jae Ik; Won, Je Hwan; Jang, Eun Ho; Lee, Sung Yeong; Ko, Kwang Tae; Jin, Bo Hwan; Lee, June Woo

    2012-01-01

    To evaluate performance and biocompatibility of a newly designed self-expanding stent graft, which consisted of two nitinol stents and an intervening expanded polytetrafluoroethylene membrane in a dog artery model. Twelve stent grafts were placed in the aorta of 6 dogs (beagle, mean body weight 11 kg) for 4 weeks (n = 4) and 12 weeks (n = 8). Luminal diameters were measured for each segment (the proximal bare, the middle graft, the distal bare) by angiographies after implantation and follow up periods. Percent luminal stenosis based on angiographies, histomorphometric, histologic, and scanning electron microscopic analyses of each segments were performed. Blood flow through the stent grafts was good after implantation and during the follow up period, without thrombotic occlusion or stent graft migration. The mean percent luminal stenosis of the proximal bare, the middle grafted and the distal bare segments after 12 weeks were 13.5%, 3.9%, 9.6% retrospectively. The mean neointimal areas of the middle grafted segment were 4.39 mm 2 (4 week) and 4.92 mm 2 (12 week). Mature endothelialization was evident in over 70% of the area of the stented artery after 4 weeks and in over 90% after 12 weeks. The stent graft was well placed in the attempted area without migration. During the 12-week-follow up period, it showed a good patency without thrombotic occlusion or significant in-stent luminal stenosis. Endothelialization was rapid and nearly complete. Neointima was thin and smooth on the middle graft segment and thicker and irregular on the bare segments.

  14. Self-expanding metal stents in benign biliary strictures due to chronic pancreatitis

    NARCIS (Netherlands)

    van Berkel, A. M.; Cahen, D. L.; van Westerloo, D. J.; Rauws, E. A.; Huibregtse, K.; Bruno, M. J.

    2004-01-01

    Background and Study Aims: In selected patients with chronic pancreatitis in whom conventional plastic stenting fails and in whom surgery is contraindicated or declined, insertion of a biliary self-expanding metal stent (SEMS) may be a valuable treatment option. Patients and Methods: Between 1994

  15. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-01-01

    Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641

  16. Self expandable polytetrafluoroethylene stent for carotid blowout syndrome.

    Science.gov (United States)

    Tatar, E C; Yildirim, U M; Dündar, Y; Ozdek, A; Işik, E; Korkmaz, H

    2012-01-01

    Carotid blowout syndrome (CBS) is an emergency complication in patients undergoing treatment for head and neck cancers. The classical management of CBS is the ligation of the common carotid artery, because suturing is not be possible due to infection and necrosis of the field. In this case report, we present a patient with CBS, in whom we applied a self-expandable polytetrafluoroethylene (PTFE) stent and observed no morbidity. Endovascular stent is a life-saving technique with minimum morbidity that preserves blood flow to the brain. We believe that this method is preferable to ligation of the artery in CBS.

  17. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of Medicine, Masan (Korea, Republic of)

    2008-06-15

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction.

  18. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon; Ko, Ji Ho

    2008-01-01

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction

  19. Subclinical leaflet thickening and stent frame geometry in self-expanding transcatheter heart valves

    DEFF Research Database (Denmark)

    Fuchs, Andreas; De Backer, Ole; Brooks, Matthew

    2017-01-01

    AIMS: This study aimed to assess the potential relationship between subclinical leaflet thickening and stent frame geometry in patients who underwent aortic valve replacement with a self-expanding transcatheter heart valve (THV). METHODS AND RESULTS: Seventy-five patients with a self-expanding THV....... CONCLUSIONS: Regional THV stent frame underexpansion is associated with an increased risk of leaflet thickening. Post-dilatation of self-expanding THV as well as a supra-annular valve position seem to reduce the occurrence of this phenomenon....

  20. Use of flow-diverting stents as salvage treatment following failed stent-assisted embolization of intracranial aneurysms.

    Science.gov (United States)

    Heiferman, Daniel M; Billingsley, Joshua T; Kasliwal, Manish K; Johnson, Andrew K; Keigher, Kiffon M; Frudit, Michel E; Moftakhar, Roham; Lopes, Demetrius K

    2016-07-01

    Flow-diverting stents, including the Pipeline embolization device (PED) and Silk, have been beneficial in the treatment of aneurysms previously unable to be approached via endovascular techniques. Recurrent aneurysms for which stent-assisted embolization has failed are a therapeutic challenge, given the existing intraluminal construct with continued blood flow into the aneurysm. We report our experience using flow-diverting stents in the repair of 25 aneurysms for which stent-assisted embolization had failed. Nineteen (76%) of these aneurysms at the 12-month follow-up showed improved Raymond class occlusion, with 38% being completely occluded, and all aneurysms demonstrated decreased filling. One patient developed a moderate permanent neurologic deficit. Appropriate stent sizing, proximal and distal construct coverage, and preventing flow diverter deployment between the previously deployed stent struts are important considerations to ensure wall apposition and prevention of endoleak. Flow diverters are shown to be a reasonable option for treating previously stented recurrent cerebral aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Orbital atherectomy as an adjunct to debulk difficult calcified lesions prior to mesenteric artery stenting.

    Science.gov (United States)

    Manunga, Jesse M; Oderich, Gustavo S

    2012-08-01

    To describe a technique in which percutaneous orbital atherectomy is used to debulk heavily calcified superior mesenteric artery (SMA) occlusions as an adjunct in patients undergoing angioplasty and stenting. The technique is demonstrated in a 62-year-old woman with a replaced right hepatic artery originating from an SMA occluded by densely calcified lesions. Via a left transbrachial approach, a 7-F MPA guide catheter was used to engage the ostium of the SMA, which was crossed using a catheter and guidewire. The calcified lesion was debulked using the 2-mm Diamondback 360° orbital atherectomy system. The wire was exchanged for a 0.014-inch filter wire and 0.018-inch guidewire. Using a 2-guidewire technique, the SMA was stented with a self-expanding stent for the distal lesion that crossed side branches and a balloon-expandable stent at the ostium. A 0.014-inch guidewire was placed into the replaced hepatic artery through a cell of the self-expanding stent, followed by deployment of a small balloon-expandable stent to address the residual lesion. The use of orbital atherectomy to debulk occluded and heavily calcified SMA lesions may optimize the technical results with angioplasty and stenting.

  2. Placement of retrievable self-expandable metallic stents with barbs into patients with obstructive prostate cancer.

    Science.gov (United States)

    Song, Ho-Young; Kim, Choung Soo; Jeong, In Gab; Yoo, Dalsan; Kim, Jin Hyoung; Nam, Deok Ho; Bae, Jae-Ik; Park, Jung-Hoon

    2013-03-01

    To evaluate the technical feasibility and clinical effectiveness of retrievable self-expandable metallic stents with barbs in patients with obstructive prostate cancer. Retrievable self-expandable metallic stents with eight barbs each were inserted into eight consecutive patients with obstructive prostate cancer. Patient ages ranged from 55 to 76 years (mean, 69 years). All eight patients had previously received hormone therapy, and three had undergone palliative transurethral prostatectomy. Stents were removed using a 21-F stent removal set if they caused complications. Stent placement was technically successful and well tolerated in all patients. One had severe incontinence, which improved spontaneously, and two had gross haematuria, which disappeared spontaneously within 4 days. Peak urine flow rates and post-void residual urine volumes 1 month after stent placement were 5.6-10.2 ml/s (mean, 8.3 ml/s), and 5-45 ml (mean, 27 ml), respectively. During a mean follow-up of 192 days (range, 39-632 days), one patient required stent removal after 232 days because of stone formation within the stent. No further intervention was required because the mass improved after stent removal. These preliminary results suggest that retrievable stents with eight barbs are both feasible to place and effective in patients with obstructive prostate cancer.

  3. Covered Metallic Stents With an Anti-Migration Design vs. Uncovered Stents for the Palliation of Malignant Gastric Outlet Obstruction: A Multicenter, Randomized Trial

    Science.gov (United States)

    Lee, Hyuk; Min, Byung-Hoon; Lee, Jeong Hoon; Shin, Cheol Min; Kim, Younjoo; Chung, Hyunsoo; Lee, Sang Hyub

    2015-01-01

    OBJECTIVES: Previous studies reported comparable stent patency between covered self-expandable metallic stents (SEMS) and uncovered SEMS (UCS) for palliation of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the efficacy and safety of the newly developed WAVE-covered SEMS (WCS), which has an anti-migration design, compared with UCS in gastric cancer patients with symptomatic GOO. METHODS: A total of 102 inoperable gastric cancer patients with symptomatic GOO were prospectively enrolled from five referral centers and randomized to undergo UCS or WCS placement. Stent patency and recurrence of obstructive symptoms were assessed at 8 weeks and 16 weeks after stent placement. RESULTS: At the 8-week follow-up, both stent patency rates (72.5% vs. 62.7%) and re-intervention rates (19.6% vs. 19.6%) were comparable between the WCS and the UCS groups. Both stent stenosis (2.4% vs. 8.1%) and migration rates (9.5% vs. 5.4%) were comparable between WCS and UCS groups. At the 16-week follow-up, however, the WCS group had a significantly higher stent patency rate than the UCS group (68.6% vs. 41.2%). Re-intervention rates in the WCS and UCS groups were 23.5% and 39.2%, respectively. Compared with the UCS group, the WCS group had a significantly lower stent restenosis rate (7.1% vs. 37.8%) and a comparable migration rate (9.5% vs. 5.4%). Overall stent patency was significantly longer in the WCS group than in the UCS group. No stent-associated significant adverse events occurred in either the WCS or UCS groups. In the multivariate analysis, WCS placement and chemotherapy were identified as independent predictors of 16-week stent patency. CONCLUSIONS: WCS group showed comparable migration rate and significantly more durable long-term stent patency compared with UCS group for the palliation of GOO in patients with inoperable gastric cancer. PMID:26372507

  4. Biomedical engineering in design and application of nitinol stents with shape memory effect

    Science.gov (United States)

    Ryklina, E. P.; Khmelevskaya, I. Y.; Morozova, Tamara V.; Prokoshkin, S. D.

    1996-04-01

    Our studies in the field of endosurgery in collaboration with the physicians of the National Research Center of Surgery of the Academy of Medical Sciences are carried out beginning in 1983. These studies laid the foundation for the new direction of X-ray surgery--X-ray Nitinol stenting of vessels and tubular structures. X-ray nitinol stents are unique self-fixing shells based on the shape memory effect and superelasticity of nickel-titanium alloys self- reconstructed under human body temperature. Applied for stenting of arteries in cases of stenosis etc., bile ducts in cases of benign and malignant stenoses, digestive tract in cases of oesophageal cancer and cervical canal uterus in cases of postsurgical atresiss and strictures of uterine. The purpose of stenting is restoration of the shape of artery or tubular structure by a cylinder frame formation. The especially elaborated original method of stenting allows to avoid the traditional surgical operation, i.e. the stenting is performed without blood, narcosis and surgical knife. The stent to be implanted is transported into the affected zone through the puncture under the X-ray control. Clinical applications of X-ray endovascular stenting has been started in March 1984. During this period nearly 400 operations on stenting have been performed on femoral, iliac, brachio-cephalic, subclavian arteries, bile ducts, tracheas, digestive tract and cervical canal uterus.

  5. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. cancerous esophagotracheal fistula: treatment of placement with covered self-expanding metallic stent

    International Nuclear Information System (INIS)

    Han Xinwei; Li Tianxiao; Wang Ruilin; Fan Qingxia

    1997-01-01

    Purpose: To treat the esophagotracheal fistula that was the main cause of death in patients with esophageal carcinoma, the placement of the stent was studied. Materials and methods: Under the fluoroscopic guidance, 28 stents (5 stents made in USA and 23 in China) were successfully implanted in all the 28 patients with esophagotracheal fistula. Results: The aphagia of the patients was greatly improved and a normal diet could be swallowed at once after the placement of the stents. The 27 cases of inhalation pneumonia that caused by the fistula was recovered. Conclusion: The result indicated that the treatment with the placement of the covered self-expanding stent is simple, safe, and effective for most patients with aphagia and pneumonia due to esophagotracheal fistula

  7. Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

    Directory of Open Access Journals (Sweden)

    Ahmed Abdel Samie

    2012-01-01

    Full Text Available Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES, and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause.

  8. Fully Covered Self-Expandable Metal Stents for Treatment of Both Benign and Malignant Biliary Disorders

    Science.gov (United States)

    Abdel Samie, Ahmed; Theilmann, Lorenz

    2012-01-01

    Transpapillary stents are increasingly being used for biliary strictures, whether benign or malignant. However, there are different stent types and available data is controversial. Recently, completely covered self-expandable metal stents (CSEMSs) have been proposed as an alternative therapeutic option in different biliary indications, including strictures of the distal bile duct, anastomotic stenosis after orthotopic liver transplantation, bile duct leaks, periampullary perforation following endoscopic sphincterotomy (ES), and postsphincterotomy bleeding. Despite the higher costs of these devices, fully covered self-expanding metal stents seem to be a suitable therapeutic option to relief biliary obstruction due to bile duct stenosis, regardless of the underlying cause. PMID:22761543

  9. Stone extraction balloon-guided repeat self-expanding metal stent placement

    Institute of Scientific and Technical Information of China (English)

    Hyung; Hun; Kim; Jeong; Seop; Moon; Soo; Hyung; Ryu; Jung; Hwan; Lee; You; Sun; Kim

    2010-01-01

    Self-expanding metal stent (SEMS) placement offers safe and effective palliation in patients with upper gastrointestinal obstruction due to a malignancy. Well described complications of SEMS placement include tumor growth, obstruction, and stent migration. SEMS occlusions are treated by SEMS redeployment, argon plasma coagulation application, balloon dilation, and surgical bypass. At our center, we usually place the second SEMS into the first SEMS if there is complete occlusion by the tumor. We discovered a...

  10. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. RESULTS: Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave’s syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. CONCLUSION: The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign

  11. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature.

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-02-16

    To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave's syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and

  12. Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention.

    Science.gov (United States)

    Uthamaraj, Susheil; Tefft, Brandon J; Hlinomaz, Ota; Sandhu, Gurpreet S; Dragomir-Daescu, Dan

    2015-09-18

    Rapid endothelialization of cardiovascular stents is needed to reduce stent thrombosis and to avoid anti-platelet therapy which can reduce bleeding risk. The feasibility of using magnetic forces to capture and retain endothelial outgrowth cells (EOC) labeled with super paramagnetic iron oxide nanoparticles (SPION) has been shown previously. But this technique requires the development of a mechanically functional stent from a magnetic and biocompatible material followed by in-vitro and in-vivo testing to prove rapid endothelialization. We developed a weakly ferromagnetic stent from 2205 duplex stainless steel using computer aided design (CAD) and its design was further refined using finite element analysis (FEA). The final design of the stent exhibited a principal strain below the fracture limit of the material during mechanical crimping and expansion. One hundred stents were manufactured and a subset of them was used for mechanical testing, retained magnetic field measurements, in-vitro cell capture studies, and in-vivo implantation studies. Ten stents were tested for deployment to verify if they sustained crimping and expansion cycle without failure. Another 10 stents were magnetized using a strong neodymium magnet and their retained magnetic field was measured. The stents showed that the retained magnetism was sufficient to capture SPION-labeled EOC in our in-vitro studies. SPION-labeled EOC capture and retention was verified in large animal models by implanting 1 magnetized stent and 1 non-magnetized control stent in each of 4 pigs. The stented arteries were explanted after 7 days and analyzed histologically. The weakly magnetic stents developed in this study were capable of attracting and retaining SPION-labeled endothelial cells which can promote rapid healing.

  13. A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications.

    Science.gov (United States)

    Jafary-Zadeh, Mehdi; Praveen Kumar, Gideon; Branicio, Paulo Sergio; Seifi, Mohsen; Lewandowski, John J; Cui, Fangsen

    2018-02-27

    Functional and mechanical properties of novel biomaterials must be carefully evaluated to guarantee long-term biocompatibility and structural integrity of implantable medical devices. Owing to the combination of metallic bonding and amorphous structure, metallic glasses (MGs) exhibit extraordinary properties superior to conventional crystalline metallic alloys, placing them at the frontier of biomaterials research. MGs have potential to improve corrosion resistance, biocompatibility, strength, and longevity of biomedical implants, and hence are promising materials for cardiovascular stent applications. Nevertheless, while functional properties and biocompatibility of MGs have been widely investigated and validated, a solid understanding of their mechanical performance during different stages in stent applications is still scarce. In this review, we provide a brief, yet comprehensive account on the general aspects of MGs regarding their formation, processing, structure, mechanical, and chemical properties. More specifically, we focus on the additive manufacturing (AM) of MGs, their outstanding high strength and resilience, and their fatigue properties. The interconnection between processing, structure and mechanical behaviour of MGs is highlighted. We further review the main categories of cardiovascular stents, the required mechanical properties of each category, and the conventional materials have been using to address these requirements. Then, we bridge between the mechanical requirements of stents, structural properties of MGs, and the corresponding stent design caveats. In particular, we discuss our recent findings on the feasibility of using MGs in self-expandable stents where our results show that a metallic glass based aortic stent can be crimped without mechanical failure. We further justify the safe deployment of this stent in human descending aorta. It is our intent with this review to inspire biodevice developers toward the realization of MG-based stents.

  14. A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications

    Directory of Open Access Journals (Sweden)

    Mehdi Jafary-Zadeh

    2018-02-01

    Full Text Available Functional and mechanical properties of novel biomaterials must be carefully evaluated to guarantee long-term biocompatibility and structural integrity of implantable medical devices. Owing to the combination of metallic bonding and amorphous structure, metallic glasses (MGs exhibit extraordinary properties superior to conventional crystalline metallic alloys, placing them at the frontier of biomaterials research. MGs have potential to improve corrosion resistance, biocompatibility, strength, and longevity of biomedical implants, and hence are promising materials for cardiovascular stent applications. Nevertheless, while functional properties and biocompatibility of MGs have been widely investigated and validated, a solid understanding of their mechanical performance during different stages in stent applications is still scarce. In this review, we provide a brief, yet comprehensive account on the general aspects of MGs regarding their formation, processing, structure, mechanical, and chemical properties. More specifically, we focus on the additive manufacturing (AM of MGs, their outstanding high strength and resilience, and their fatigue properties. The interconnection between processing, structure and mechanical behaviour of MGs is highlighted. We further review the main categories of cardiovascular stents, the required mechanical properties of each category, and the conventional materials have been using to address these requirements. Then, we bridge between the mechanical requirements of stents, structural properties of MGs, and the corresponding stent design caveats. In particular, we discuss our recent findings on the feasibility of using MGs in self-expandable stents where our results show that a metallic glass based aortic stent can be crimped without mechanical failure. We further justify the safe deployment of this stent in human descending aorta. It is our intent with this review to inspire biodevice developers toward the realization

  15. A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications

    Science.gov (United States)

    Jafary-Zadeh, Mehdi; Praveen Kumar, Gideon

    2018-01-01

    Functional and mechanical properties of novel biomaterials must be carefully evaluated to guarantee long-term biocompatibility and structural integrity of implantable medical devices. Owing to the combination of metallic bonding and amorphous structure, metallic glasses (MGs) exhibit extraordinary properties superior to conventional crystalline metallic alloys, placing them at the frontier of biomaterials research. MGs have potential to improve corrosion resistance, biocompatibility, strength, and longevity of biomedical implants, and hence are promising materials for cardiovascular stent applications. Nevertheless, while functional properties and biocompatibility of MGs have been widely investigated and validated, a solid understanding of their mechanical performance during different stages in stent applications is still scarce. In this review, we provide a brief, yet comprehensive account on the general aspects of MGs regarding their formation, processing, structure, mechanical, and chemical properties. More specifically, we focus on the additive manufacturing (AM) of MGs, their outstanding high strength and resilience, and their fatigue properties. The interconnection between processing, structure and mechanical behaviour of MGs is highlighted. We further review the main categories of cardiovascular stents, the required mechanical properties of each category, and the conventional materials have been using to address these requirements. Then, we bridge between the mechanical requirements of stents, structural properties of MGs, and the corresponding stent design caveats. In particular, we discuss our recent findings on the feasibility of using MGs in self-expandable stents where our results show that a metallic glass based aortic stent can be crimped without mechanical failure. We further justify the safe deployment of this stent in human descending aorta. It is our intent with this review to inspire biodevice developers toward the realization of MG-based stents

  16. Self-expandable metal stents in the treatment of benign anastomotic stricture after rectal resection for cancer.

    Science.gov (United States)

    Lamazza, A; Fiori, E; Sterpetti, A V; Schillaci, A; Scoglio, D; Lezoche, E

    2014-04-01

    To evaluate the use of self-expandable metallic stents to treat patients with symptomatic benign anastomotic stricture after colorectal resection. Ten patients with a benign symptomatic anastomotic stricture after colorectal resection were treated with endoscopic placement of a self-expandable metal stent. The stent was placed successfully in all 10 patients without any major morbidity. At a mean follow-up of 18 months the stenosis was resolved successfully in 7 out 10 patients (70%). The remaining three patients were subsequently treated successfully with balloon dilatation. Self-expandable metal stents represent a valid alternative to balloon dilatation to treat patients with benign symptomatic anastomotic stricture after colorectal resection for cancer. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  17. Self-expandable metallic stents for patients with recurrent esophageal carcinoma after failure of primary chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Muto, Manabu; Ohtsu, Atsushi; Boku, Narikazu; Yoshida, Shigeaki [National Cancer Center, Kashiwa, Chiba (Japan). Hospital East; Miyata, Yoshinori; Shioyama, Yasukazu

    2001-06-01

    Recent advances in chemoradiotherapy for esophageal carcinoma have resulted in improved survival rates. However, there are few options for recurrent dysphagia due to refractory carcinoma after failure of primary chemoradiotherapy. The aim of this study was to evaluate the safety and efficacy of self-expandable metallic stent placement for patients with recurrent esophageal carcinoma where definitive chemoradiotherapy has failed. Thirteen consecutive patients with recurrent squamous cell carcinoma of the esophagus, in whom self-expandable metallic stents were placed after failure of primary chemoradiotherapy, were studied retrospectively. All patients had esophageal obstruction or malignant fistula. The oral alimentation status of nine of 13 patients (69%) improved after successful placement of the stent. Following placement of the stent, fever (>38 deg C) and severe chest pain occurred in 85% (11/13) of the patients. In all patients examined, C-reactive protein was elevated within 1 week of the operation. Esophageal perforation occurred in three patients. Stent-related mediastinitis and pneumonia developed in six (46%) and three (23%) patients, respectively. Seven of the 13 patients (54%) died of stent-related pulmonary complications. Although the placement of a self-expandable metallic stent for patients with recurrent esophageal carcinoma after failure of chemoradiotherapy improved their oral alimentation status, we found that this treatment increases the risk of life-threatening pulmonary complications. (author)

  18. Self-expandable metallic stents for patients with recurrent esophageal carcinoma after failure of primary chemoradiotherapy

    International Nuclear Information System (INIS)

    Muto, Manabu; Ohtsu, Atsushi; Boku, Narikazu; Yoshida, Shigeaki; Miyata, Yoshinori; Shioyama, Yasukazu

    2001-01-01

    Recent advances in chemoradiotherapy for esophageal carcinoma have resulted in improved survival rates. However, there are few options for recurrent dysphagia due to refractory carcinoma after failure of primary chemoradiotherapy. The aim of this study was to evaluate the safety and efficacy of self-expandable metallic stent placement for patients with recurrent esophageal carcinoma where definitive chemoradiotherapy has failed. Thirteen consecutive patients with recurrent squamous cell carcinoma of the esophagus, in whom self-expandable metallic stents were placed after failure of primary chemoradiotherapy, were studied retrospectively. All patients had esophageal obstruction or malignant fistula. The oral alimentation status of nine of 13 patients (69%) improved after successful placement of the stent. Following placement of the stent, fever (>38 deg C) and severe chest pain occurred in 85% (11/13) of the patients. In all patients examined, C-reactive protein was elevated within 1 week of the operation. Esophageal perforation occurred in three patients. Stent-related mediastinitis and pneumonia developed in six (46%) and three (23%) patients, respectively. Seven of the 13 patients (54%) died of stent-related pulmonary complications. Although the placement of a self-expandable metallic stent for patients with recurrent esophageal carcinoma after failure of chemoradiotherapy improved their oral alimentation status, we found that this treatment increases the risk of life-threatening pulmonary complications. (author)

  19. Outcomes of second self-expandable metallic stent insertion for malignant gastric outlet obstruction.

    Science.gov (United States)

    Kim, Chan Gyoo; Choi, Il Ju; Lee, Jong Yeul; Cho, Soo-Jeong; Kim, Soo Jin; Kim, Mi-Jung; Park, Sook Ryun; Park, Young Lee

    2014-01-01

    Self-expandable metallic stents are used widely to relieve malignant gastric outlet obstruction (GOO). However, restenosis or migration of first stents is a frequent complication. The purpose of this retrospective cohort study was to evaluate the effectiveness of second stents as an approach to manage failure of first stents in patients with malignant GOO. A total of 222 patients with gastric cancer received first stents due to inoperable GOO at National Cancer Center in Korea between January 2008 and June 2011. Monthly follow-up interviews were performed, and second stents (stent-in-stent or stent-after-migration) were inserted in 59 patients by June 2012. Technical and clinical successes and long-term complications were evaluated. The technical and immediate clinical success rates were 98.3 % (58/59) and 91.5 % (54/59), respectively. Patients who received a second stent due to late complications involving the first stent (migration, restenosis, and fracture) showed a higher clinical success rate (95.8 % [46/48]) than patients who received a second stent due to immediate clinical failure of the first stent (72.7 % [8/11], p = 0.04). The immediate clinical success rate of stent-after-migration (100 % [11/11]) was not different from that of stent-in-stent (89.6 % [43/48], p = 1.0). The stent dysfunction rate of stent-after-migration (27.3 % [3/11]) also was similar to that of stent-in-stent (29.2 % [14/48], p = 1.0). The median patencies of stent-in-stent and stent-after-migration were 27.4 and 58.4 weeks, respectively (p = 0.177). There were no significant prognostic factors for patency of second stents. Insertion of a second stent is effective for treating the first-stent failure in gastric cancer patients with GOO, especially if the immediate outcome of the first stent was successful.

  20. Use of Self-Expanding Stents for the Treatment of Vertebral Artery Ostial Stenosis: a Single Center Experience

    International Nuclear Information System (INIS)

    Chung, Sun Young; Lee, Deok Hee; Choi, Jin Woo; Choi, Byung Se; In, Hyun Sin; Kim, Sun Mi; Choi, Choong Gon; Kim, Sang Joon; Suh, Dae Chul

    2010-01-01

    To evaluate our early experience using self-expanding stents to treat atherosclerotic vertebral artery ostial stenosis (VAOS), with respect to technical feasibility and clinical and imaging follow-up results. A total of 20 lesions in 20 patients underwent stenting of the VAOS using a self-expanding stent (Precise RX; Cordis Neurovascular, Miami Lakes, FL). Two patients were asymptomatic. We analyzed the technical success rate, causes of technical failure, occurrence of any vascular or neurological event, and the occurrence of any neurological abnormality or in-stent restenosis (ISR) seen on follow-up. The imaging follow-up was performed with Doppler ultrasound (DUS) as a primary screening modality. One instance of technical failure was caused by failure of the guidewire passage. The stent diameter was 5 mm, and post-stenting balloon dilatations were necessary in all cases. Stent misplacement requiring placement of an additional stent occurred in four cases. Following a 14.8 month average clinical follow-up time, two patients showed anterior circulation ischemia, which was not attributed to the VAOS we treated. Following a 13.7 month average DUS follow-up, five patients showed a mild degree of diffuse or focal intimal thickening in the stent lumen; however, none of the stenosis showed luminal loss of more than 50% and no stent fracture was noted. The use of self-expanding stents for treating VAOS was technically feasible and helped to improve artery patency during our limited follow-up interval

  1. Clinical application of self-expandable metallic stents in the treatment of malignant tracheal stenosis under general anesthesia

    International Nuclear Information System (INIS)

    Wang Weitao; Shi Haibin; Yang Zhengqiang; Liu Sheng; Zhou Chungao; Zhao Linbo; Xia Jinguo; Li Linsun

    2009-01-01

    Objective: To evaluate the safety and efficacy of self-expandable metallic stent placement for the treatment of malignant tracheal stenosis under general anesthesia and fluoroscopic guidance. Methods: Under general anesthesia the placement of self-expandable metallic stent was performed in 10 patients with malignant tracheal stenosis, the procedure was completed under fluoroscopic guidance in all patients. Results: Successful tracheal stenting was achieved in all 10 patients. In one patient, a Y-shaped stent was used as the tracheal carina was involved in the airway stenosis. The symptoms of dyspnea and asthma were markedly improved immediately after the implantation of stent in all patients. Conclusion: Tracheal implantation of self-expandable metallic stent under general anesthesia and fluoroscopic guidance is a safe and effective treatment for malignant tracheal stenosis, it can promptly relieve various symptoms caused by malignant tracheal stenosis and obviously improve patient's living quality, therefore,t his technique is of great value in clinical practice. (authors)

  2. Role of metallic stents in benign esophageal stricture

    Science.gov (United States)

    Shim, Chan Sup

    2012-10-01

    Simple esophageal strictures, which are focal, straight, and large in diameter, usually require 1 - 3 dilation sessions to relieve symptoms. However, complex strictures, which are long, tortuous, or associated with a severely compromised luminal diameter, are usually more difficult to treat with conventional bougie or balloon dilation techniques, and often have high recurrence rates. Although the permanent placement of self-expandable metal stents (SEMS) has been used to manage refractory benign esophageal strictures, this procedure is associated with additional problems, such as stricture from tissue hyperplasia, stent migration, and fistula formation. Thus, several new types of stents have been developed, including temporary SEMS, self-expandable plastic stents (SEPS), and biodegradable stents. The use of these new products has produced varied results. Temporary SEMS that have been used to relieve benign esophageal conditions have caused granulation tissue at both ends of the stent because of contact between the mucosa and the exposed metal components of the stent, thus hindering stent removal. We examined the tissue response to two new types of SEMS, a flange-type and a straighttype, each coated with a silicone membrane on the outside of the metal mesh. These two SEMS were evaluated individually and compared with a conventional control stent in animal experiments. Although the newly designed stents resulted in reduced tissue hyperplasia, and were thus more easily separated from the esophageal tissue, some degree of tissue hyperplasia did occur. We suggest that newly designed DES (drug-eluting stents) may provide an alternative tool to manage refractory benign esophageal stricture.

  3. Feasibility study for the investigation of Nitinol self-expanding stents by neutron techniques

    International Nuclear Information System (INIS)

    Rogante, M.; Pasquini, U.; Rosta, L.; Lebedev, V.

    2011-01-01

    In this paper, neutron techniques - in particular, small angle neutron scattering (SANS) and neutron diffraction (ND) - are considered for the non-destructive characterization of Nitinol artery stents. This roughly equiatomic (50Ni-50Ti at%) shape memory alloy (SMA) exhibits significant properties of superelasticity and biocompatibility that make it suitable to be typically used as smart material for medical implants and devices. Nitinol self-expanding artery stents, as permanent vascular support structures, supply an ideal option to bypass surgery, but they are submitted for the whole of patient's life to the dynamical stress of the artery pulsation and the aggression from the biological environment. These stents, consequently, can suffer from wear and fracture occurrence likely due to a variety of cyclic fatigue, overload conditions and residual stresses. Neutrons have recently become a progressively more important probe for various materials and components and they allow achieving information complementary to those obtained from the traditional microstructural analyses. The outputs from the preliminary works already carried out in this field consent to consider neutron techniques capable to contribute to the development of these crucial medical implants. The achievable results can yield trends adoptable in monitoring of the stent features. -- Research Highlights: → Neutron techniques can contribute to develop Nitinol self-expanding artery stents. → Neutrons investigations can help avoiding wear and fracture events in Nitinol stents. → Neutron techniques can yield trends adoptable in monitoring of Nitinol stent features. → SANS is able to perform a micro- and nano-scale characterization of Nitinol stents. → Neutron Diffraction helps assessing stresses due to the exercise in Nitinol stents.

  4. Self-expandable metal stents for malignant colonic obstruction: data from a retrospective regional SIED-AIGO study.

    Science.gov (United States)

    Di Mitri, Roberto; Mocciaro, Filippo; Traina, Mario; Montalbano, Luigi Maria; Familiari, Luigi; D'Amore, Fabio; Raimondo, Dario; Virgilio, Clara; Tarantino, Ilaria; Barresi, Luca; Giunta, Marco; Borina, Eleonora; Borruto, Antonino; Marino, Antonino

    2014-03-01

    Self-expandable metal stents are a non-surgical option for the treatment of symptomatic malignant colorectal obstruction as palliative treatment or as a bridge to surgery. To report data from a regional study on self-expandable metal stent (SEMS) placement for malignant colorectal obstruction. Two hundred and four patients (male 54.9%, mean age of 69.5 ± 14.2) were retrospectively evaluated and data on technical and clinical success, and complications, were analyzed. Technical and clinical success rates were 99% and 94.6% respectively, with 36.7% treated on an emergency basis and 63.3% electively. Palliative treatment was administered to 70.1%, and as a bridge to surgery for 29.9%. Complications were 17 neoplastic ingrowths, 10 stent migrations, and 4 perforations. Palliative treatment was associated with a higher risk of stent ingrowth (p=0.003), and chemotherapy with a lower risk of stent ingrowth (p=0.009). This regional study, although it has certain limitations, confirms the positive role of self-expandable metal stents in the treatment of symptomatic malignant colorectal obstruction, and that chemotherapy decreases the risk of ingrowth. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  5. Refinement of a thrombectomy technique to treat acute ischemic stroke: Technical note on microcatheter advance during retrieving self expandable stent

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Catholic Univ. of Daegu School of Medicine, Daegu (Korea, Republic of)

    2012-07-15

    Temporary stenting and thrombectomy by use of the Solitaire stent (ev3, Irvine, CA, USA) has shown prompt and successful recanalization of the acutely occluded major cerebral artery. However, even if rarely reported, inadvertent stent detachment may occur as an innate drawback and full deployment of the stent was considered to increase the risk. In our patients, the Solitaire stent did not fully unfold to prevent inadvertent detachment. Before retrieval of the stent, the tip of the microcatheter was advanced forward carefully under fluoroscopic observation until it met the presumed thrombus segment and a subtle sense of resistance was felt in the fingers guiding the stent. After retrieval, complete recanalization was achieved, and the thrombus was trapped between the tip of the microcatheter and the stent strut. We present 2 cases of successful thrombi captures by advancing a microcatheter during Solitaire stent retrieval, and we suggest that advancing the microcatheter can be a useful refinement to the thrombectomy technique for acute ischemic stroke.

  6. Primary Self-Expandable Nitinol Stent Placement in Focal Lesions of Infrarenal Abdominal Aorta: Long Term Results

    International Nuclear Information System (INIS)

    Lastovickova, Jarmila; Peregrin, Jan H.

    2008-01-01

    Purpose. To evaluate the technical and clinical success, safety and long term results of percutaneous transluminal angioplasty/self-expandable nitinol stent placement of infrarenal abdominal aorta focal lesions. Materials and Methods. Eighteen patients underwent PTA of focal atherosclerotic occlusive disease of distal abdominal aorta. Two symptomatic occlusions and 16 stenoses in 10 male and 8 female patients (mean age 68.2 years) were treated with primary self-expandable nitinol stent placement. Results. Primary self-expandable nitinol stent placement was technically successful in all 18 procedures; clinical success was achieved in 100% of patients. No complications associated with the procedure occurred. During the 49.4 months of mean follow up (range 3-96, 4 months) all treated aortic segments remained patent. Conclusions. Endovascular treatment (primary self-expandable nitinol stent placement) of focal atherosclerotic lesions of distal abdominal aorta is a safe method with excellent primary technical and clinical success rates and favourable Long term results

  7. Management of acute malignant colorectal obstruction with a novel self-expanding metallic stent as a bridge to surgery

    International Nuclear Information System (INIS)

    Li Yongdong; Cheng Yingsheng; Li Minghua; Fan Youben; Chen Niwei; Wang Yu; Zhao Jungong

    2010-01-01

    Purpose: To prospectively evaluate the safety and clinical efficacy of a newly designed self-expandable metallic stent (SEMS) in the treatment of patients with acute malignant colorectal obstruction. Methods: Between April 2001 and October 2007, 52 patients with acute malignant colorectal obstruction were treated with a new designed SEMS as an investigational bridge to surgery. Patients were prospectively followed and relevant data collection was collected, including details regarding technique, clinical symptoms, complications, need for elective surgery, and overall survival. Results: Stent placement was technically successful in all but two patients (due to complete obstruction) with no procedure-related complications. Complications included stent migration (n = 4), anal pain (n = 2) and stool impaction (n = 1). Clinical success was achieved in 49 (98%) of 50 patients with resolution of bowel obstruction within 2 days of stent placement. In one patient with stool impaction 2 days after stent placement, endoscopic disimpaction was successfully performed. An elective one-stage surgical procedure was performed in all 50 patients who successfully received a SEMS as a bridge to surgery within a mean of 8 ± 2 days (range: 4-11 days) after stent placement. Mean follow-up time was 36 ± 12 months (range 3-70 months), and all patients remained alive at the time of this report. Conclusion: The newly designed SEMS placement as a bridge to surgery was a safe and effective intervention for colonic decompression in patients with acute malignant colorectal obstruction and allowed a high proportion of patients to be successfully proceeded to elective surgery.

  8. Management of acute malignant colorectal obstruction with a novel self-expanding metallic stent as a bridge to surgery

    Energy Technology Data Exchange (ETDEWEB)

    Li Yongdong [Department of Radiology and Research Institute of Radiology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University, No. 600, Yi Shan Road, Shanghai 200233 (China); Cheng Yingsheng [Department of Radiology and Research Institute of Radiology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University, No. 600, Yi Shan Road, Shanghai 200233 (China); Department of Radiology, Tenth Affiliated People' s Hospital, Shanghai Tong Ji University, No. 301, Middle Yan Chang Road, Shanghai 200072 (China)], E-mail: chengys@sh163.net; Li Minghua [Department of Radiology and Research Institute of Radiology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University, No. 600, Yi Shan Road, Shanghai 200233 (China); Fan Youben; Chen Niwei; Wang Yu [Department of Gastroenterology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University (China); Zhao Jungong [Department of Radiology and Research Institute of Radiology, Sixth Affiliated People' s Hospital, Shanghai Jiao Tong University, No. 600, Yi Shan Road, Shanghai 200233 (China)

    2010-03-15

    Purpose: To prospectively evaluate the safety and clinical efficacy of a newly designed self-expandable metallic stent (SEMS) in the treatment of patients with acute malignant colorectal obstruction. Methods: Between April 2001 and October 2007, 52 patients with acute malignant colorectal obstruction were treated with a new designed SEMS as an investigational bridge to surgery. Patients were prospectively followed and relevant data collection was collected, including details regarding technique, clinical symptoms, complications, need for elective surgery, and overall survival. Results: Stent placement was technically successful in all but two patients (due to complete obstruction) with no procedure-related complications. Complications included stent migration (n = 4), anal pain (n = 2) and stool impaction (n = 1). Clinical success was achieved in 49 (98%) of 50 patients with resolution of bowel obstruction within 2 days of stent placement. In one patient with stool impaction 2 days after stent placement, endoscopic disimpaction was successfully performed. An elective one-stage surgical procedure was performed in all 50 patients who successfully received a SEMS as a bridge to surgery within a mean of 8 {+-} 2 days (range: 4-11 days) after stent placement. Mean follow-up time was 36 {+-} 12 months (range 3-70 months), and all patients remained alive at the time of this report. Conclusion: The newly designed SEMS placement as a bridge to surgery was a safe and effective intervention for colonic decompression in patients with acute malignant colorectal obstruction and allowed a high proportion of patients to be successfully proceeded to elective surgery.

  9. Advantages and disadvantages of biodegradable platforms in drug eluting stents.

    Science.gov (United States)

    Rodriguez-Granillo, Agustina; Rubilar, Bibiana; Rodriguez-Granillo, Gaston; Rodriguez, Alfredo E

    2011-03-26

    Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to bare-metal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.

  10. [Self-expanding nitinol stents in proximal tracheal stenosis].

    Science.gov (United States)

    Hafner, B; Mann, W; Heussel, C P; Scherhag, A; Schlegel, J; Kauczor, H U

    2000-03-01

    The use of silicone- or metal stents in stenosis of the distal trachea and the bronchial system is a customary procedure [1-4], for example after tumor invasion or cicatricial stenosis after transplantation. In the proximal part of the trachea, on smaller, short and soft strictures we try to stabilise the trachea by the implantation of rings. Other methods are tracheal plasty or transverse tracheal resectomy [5-7]. In the case of longer or nearer subglottal stenoses the positioning of self-expanding nitinol stents has proven a simple, gentle and well-tolerated alternative procedure even in very serious disorders [1, 8, 9]. These stents can be placed in short narcosis under endoscopic control without great strain on the patient. We placed nitinol-stents in the proximal part of the trachea in eleven cases. In five cases dyspnoea caused by a tracheal collapse improved. In two further cases a tracheal stenosis with massive granulation tissue and cicatricial pull under an inlaid tracheal cannula was removed and the tracheostoma was closed. In four cases a solid, scarred and cartilaginous stenosis in the area of the cricoid and the upper tracheal rings was widened with laser and later on stented. Over an observation time of two years no complications showed safe one case in which a directly postoperative dislocation was repositioned quickly. The patients live without restrictions through the tracheal stenosis or a tracheostoma. In the best possible case epithelialization over the metal meshes develops so that a nearly normal mucus transportation is possible [1, 10-12].

  11. Upper Gastrointestinal Stent Insertion in Malignant and Benign Disorders

    Science.gov (United States)

    Kang, Hyoun Woo

    2015-01-01

    Upper gastrointestinal (GI) stents are increasingly being used to manage upper GI obstructions. Initially developed for palliative treatment of esophageal cancer, upper GI stents now play an emerging role in benign strictures of the upper GI tract. Because recurrent obstruction and stent-related complications are common, new modifications of stents have been implemented. Self-expandable metal stents (SEMS) have replaced older plastic stents. In addition, newly designed SEMS have been developed to prevent complications. This review provides an overview of the various types, indications, methods, complications, and clinical outcomes of upper GI stents in a number of malignant and benign disorders dividing the esophagus and gastroduodenum. PMID:26064817

  12. Enterprise Deployment Through PulseRider To Treat Anterior Communicating Artery Aneurysm Recurrence.

    Science.gov (United States)

    Valente, Iacopo; Limbucci, Nicola; Nappini, Sergio; Rosi, Andrea; Laiso, Antonio; Mangiafico, Salvatore

    2018-02-01

    PulseRider (Pulsar Vascular, Los Gatos, California, USA) is a new endovascular device designed to treat wide-neck bifurcation intracranial aneurysms. Deployment of a stent through a PulseRider to treat an aneurysm's recurrence has never been described before. We report the case of a 55-year-old man who underwent coiling of an 8-mm anterior communicating artery aneurysm with assistance of a PulseRider neck reconstruction device. The 6-month digital subtraction angiography control showed aneurysm recurrence, so we deployed an Enterprise 2 closed-cell stent (Codman, Miami Lakes, Florida, USA) in the A1-A2 segment passing across the previously implanted PulseRider. Enterprise correctly expanded and allowed for adequate coiling of the aneurysm. An Enterprise stent can be safely opened through a PulseRider in order to treat aneurysm recurrence. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  14. [Clinical application of a fully covered self-expandable metallic stent in treatment of airway fistula].

    Science.gov (United States)

    Zhu, Qiang; Zang, Qi; Jiang, Zhong-min; Wang, Wei; Cao, Ming

    2013-06-01

    To assess the feasibility, safety and efficacy of the use of a fully covered self-expandable stent for the treatment of airway fistula. From August 2005 to November 2011, 9 patients underwent treatment by the introduction of a tracheo-bronchial or bronchial fully covered self-expandable metallic stent. There were 7 males and 2 females, aged from 28-65 years with a mean of 46 years. In this group, 7 cases were diagnosed as bronchopleural fistula, 1 case as tracheopleural fistula, 1 case as broncho-esophageal fistula, 8 cases with thoracic empyema. The fistula orifices were from 3.5-25.0 mm in diameter with a mean 8.4 mm. All patients received topical anesthesia, and L-shaped stent was placed in 6 patients and I-shaped stent in 3 patients under fluoroscopic guidance. After the stent placement, the patients with empyema were treated with continual irrigation of the empyema cavity. Stent placement in the tracheo-bronchial tree was technically successful in all patients, without procedure-related complications. The operating time was from 5-16 minutes, mean time (10 ± 4) minutes. Except for 1 patient, immediate closure of the airway fistula was achieved in the other patients after the procedure, as shown by the immediate cessation of bubbling in the chest drain system or the contrast examination. In this study, 1 patient coughed the inserted stent out due to irritable cough on the 5th day and had to receive repositioning of a new stent. Among the patients who were with empyema, 1 patient died of septicemia on the 8th day and 1 patient died of brain metastases from lung cancer 6 months after the stent insertion with empyema not cured, the other 6 patients' empyema healed from 2-5 months, mean time 3.7 months. Seven patients were followed from 3 to 36 months with a median of 13.5 months. During follow-up, 1 stent was removed from a patient 8 months after the stent implantation without empyema recurred. The remaining patient presented good tolerability to the existence of

  15. History of the Use of Esophageal Stent in Management of Dysphagia and Its Improvement Over the Years.

    Science.gov (United States)

    Dua, Kulwinder S

    2017-02-01

    The art and science of using stents to treat dysphagia and seal fistula, leaks and perforations has been evolving. Lessons learnt from the deficiencies of previous models led to several improvements making stent deployment easier, and with some designs, it was also possible to remove the stents if needed. With these improvements, besides malignant dysphagia, newer indications for using stents emerged. Unfortunately, despite several decades of evolution, as yet, there is no perfect stent that "fits all." This article is an overview of how this evolution process happened and where we are currently with using stents to manage patients with dysphagia and with other esophageal disorders.

  16. Optimization of detector pixel size for stent visualization in x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Jiang Yuhao; Wilson, David L.

    2006-01-01

    Pixel size is of great interest in the flat-panel detector design because of its potential impact on image quality. In the particular case of angiographic x-ray fluoroscopy, small pixels are required in order to adequately visualize interventional devices such as guidewires and stents which have wire diameters as small as 200 and 50 μm, respectively. We used quantitative experimental and modeling techniques to investigate the optimal pixel size for imaging stents. Image quality was evaluated by the ability of subjects to perform two tasks: detect the presence of a stent and discriminate a partially deployed stent from a fully deployed one in synthetic images. With measurements at 50, 100, 200, and 300 μm, the 100 μm pixel size gave the maximum contrast sensitivity for the detection experiment with the idealized direct detector. For an idealized indirect detector with a scintillating layer, an optimal pixel size was obtained at 200 μm pixel size. A channelized human observer model predicted a peak at 150 and 170 μm, for the idealized direct and indirect detectors, respectively. With regard to the stent deployment task for both detector types, smaller pixel sizes are favored and there is a steep drop in performance with larger pixels. In general, with the increasing exposures, the model and measurements give the enhanced contrast sensitivities and a smaller optimal pixel size. The effects of electronic noise and fill factor were investigated using the model. We believe that the experimental results and human observer model predications can help guide the flat-panel detector design. In addition, the human observer model should work on the similar images and be applicable to the future model and actual flat-panel implementations

  17. Comparison between uncovered and covered self-expandable metal stent placement in malignant duodenal obstruction.

    Science.gov (United States)

    Kim, Ji Won; Jeong, Ji Bong; Lee, Kook Lae; Kim, Byeong Gwan; Ahn, Dong Won; Lee, Jae Kyung; Kim, Su Hwan

    2015-02-07

    To compare the clinical outcomes of uncovered and covered self-expandable metal stent placements in patients with malignant duodenal obstruction. A total of 67 patients were retrospectively enrolled from January 2003 to June 2013. All patients had symptomatic obstruction characterized by nausea, vomiting, reduced oral intake, and weight loss. The exclusion criteria included asymptomatic duodenal obstruction, perforation or peritonitis, concomitant small bowel obstruction, or duodenal obstruction caused by benign strictures. The technical and clinical success rate, complication rate, and stent patency were compared according to the placement of uncovered (n = 38) or covered (n = 29) stents. The technical and clinical success rates did not differ between the uncovered and covered stent groups (100% vs 96.6% and 89.5% vs 82.8%). There were no differences in the overall complication rates between the uncovered and covered stent groups (31.6% vs 41.4%). However, stent migration occurred more frequently with covered than uncovered stents [20.7% (6/29) vs 0% (0/38), P stent patency was longer in uncovered than in covered stents [251 d (95%CI: 149.8 d-352.2 d) vs 139 d (95%CI: 45.5 d-232.5 d), P stent (70 d) and covered stent groups (60 d). Uncovered stents may be preferable in malignant duodenal obstruction because of their greater resistance to stent migration and longer stent patency than covered stents.

  18. An agent-based model of the response to angioplasty and bare-metal stent deployment in an atherosclerotic blood vessel.

    Directory of Open Access Journals (Sweden)

    Antonia E Curtin

    Full Text Available PURPOSE: While animal models are widely used to investigate the development of restenosis in blood vessels following an intervention, computational models offer another means for investigating this phenomenon. A computational model of the response of a treated vessel would allow investigators to assess the effects of altering certain vessel- and stent-related variables. The authors aimed to develop a novel computational model of restenosis development following an angioplasty and bare-metal stent implantation in an atherosclerotic vessel using agent-based modeling techniques. The presented model is intended to demonstrate the body's response to the intervention and to explore how different vessel geometries or stent arrangements may affect restenosis development. METHODS: The model was created on a two-dimensional grid space. It utilizes the post-procedural vessel lumen diameter and stent information as its input parameters. The simulation starting point of the model is an atherosclerotic vessel after an angioplasty and stent implantation procedure. The model subsequently generates the final lumen diameter, percent change in lumen cross-sectional area, time to lumen diameter stabilization, and local concentrations of inflammatory cytokines upon simulation completion. Simulation results were directly compared with the results from serial imaging studies and cytokine levels studies in atherosclerotic patients from the relevant literature. RESULTS: The final lumen diameter results were all within one standard deviation of the mean lumen diameters reported in the comparison studies. The overlapping-stent simulations yielded results that matched published trends. The cytokine levels remained within the range of physiological levels throughout the simulations. CONCLUSION: We developed a novel computational model that successfully simulated the development of restenosis in a blood vessel following an angioplasty and bare-metal stent deployment based on

  19. Self-expandable covered metallic esophageal stent impregnated with beta-emitting radionuclide: an experimental study in canine esophagus

    International Nuclear Information System (INIS)

    Won, Je Hwan; Lee, Jong Doo; Wang, Hee Jung; Kim, Gui-Eon; Kim, Bong Wan; Yim, Hyunee; Han, Sang Keon; Park, Chan H.; Joh, Chul Woo; Kim, Kyung-Hwa; Park, Kyung Bae; Shin, Kyong-Min

    2002-01-01

    Purpose: A specially designed self-expandable covered metallic stent impregnated with the β-emitting radioisotope 166 Ho ( 166 Ho, energy: 1.85 and 1.76 MeV, T((1)/(2)): 26.8 h) was developed at our institute for the purpose of intraluminal palliative brachytherapy, as well as for treating malignant esophageal stricture and swallowing difficulty. The aim of this study was to evaluate the tissue response to brachytherapy and the safety of the radioactive metallic stent with regard to the normal canine esophagus before clinical application. Methods and Materials: 166 Ho was impregnated into the polyurethane membrane (50 μ thickness) covering the outer surface of a self-expandable metallic stent (diameter, 18 mm; length, 40 mm). Stents with radioactivity 4.0-7.8 mCi (Group A, n=15), 1.0-1.8 mCi (Group B, n 5), and 0.5-0.7 mCi (Group C, n=5) were placed in the esophagi of 25 healthy beagle dogs, and the stents were tightly anchored surgically to prevent migration. The estimated radiation dose calculated by Monte Carlo simulation was 194-383 Gy in Group A, 48-90 Gy in Group B, and 23-32 Gy in Group C. The dogs were killed 8-12 weeks after insertion of the stents, and histologic examinations of the esophageal walls were performed. Results: In Group A, 3 of 15 dogs died of wound infection, so specimens were obtained from only 12 dogs; all 12 cases showed esophageal stricture with mucosal ulceration. Microscopically, severe fibrosis and degeneration of the muscular propria were found in 3 dogs, complete fibrosis of the entire esophageal wall was found in 7 dogs, and esophageal fibrosis with radiation damage within periesophageal soft tissue was found in 2 dogs. However, esophageal perforation did not develop, despite extremely high radiation doses. In Group B, glandular atrophy and submucosal fibrosis were found, but the muscular layer was intact. In Group C, no histologic change was found in 3 dogs, but submucosal inflammation and glandular atrophy with intact mucosa

  20. Removal of self expandable metallic airway stent: A rare case report

    OpenAIRE

    Chawla, Rakesh K.; Madan, Arun; Singh, Ishwar; Mudoiya, Rahul; Chawla, Aditya; Gupta, Radha; Chawla, Kiran; Chhabra, Roopam

    2013-01-01

    Covered self expandable metallic airway stents (SEMS) have been used for benign tracheal stenosis, post intubation tracheal stenosis, tracheal burn or trauma, tracheo-broncho-malacia, and extrinsic compression of trachea. Their placement is considered to be permanent, with open surgery the only way to remove the stent, though there are few cases reports of their removal with the bronchoscope, but the complications after their removal are very high. In our patient, one and a half years after p...

  1. Randomized multicenter study of multiple plastic stents vs. covered self-expandable metallic stent in the treatment of biliary stricture in chronic pancreatitis.

    Science.gov (United States)

    Haapamäki, Carola; Kylänpää, Leena; Udd, Marianne; Lindström, Outi; Grönroos, Juha; Saarela, Arto; Mustonen, Harri; Halttunen, Jorma

    2015-07-01

    The use of covered self-expandable metallic stents (cSEMS) in benign biliary indications is evolving. The aim of the study was to assess the safety and feasibility of cSEMS compared with multiple plastic stents in the treatment of benign biliary stricture (BBS) caused by chronic pancreatitis. This was a prospective, multicenter, randomized study of 60 patients with BBS caused by chronic pancreatitis. All patients received an initial plastic stent before randomization. At randomization, the stent was replaced either with a single cSEMS or three plastic stents. After 3 months, the position of the cSEMS was checked or another three plastic stents were added. At 6 months after randomization, all stents were removed. Clinical follow-up including abdominal ultrasound and laboratory tests were performed at 6 months and 2 years after stent removal. Two patients dropped out of the cSEMS group before stent removal. In April 2014, the median follow-up was 40 months (range 1 - 66 months). The 2-year, stricture-free success rate was 90 % (95 % confidence interval [CI] 72 % - 97 %) in the plastic stent group and 92 % (95 %CI 70 % - 98 %) in the cSEMS group (P = 0.405). There was one late recurrence in the plastic stent group 50 months after stent removal. Stent migration occurred three times (10 %) in the plastic stent group and twice in the cSEMS group (7 %; P = 1.000). A 6-month treatment with either six 10-Fr plastic stents or with one 10-mm cSEMS produced good long-term relief of biliary stricture caused by chronic pancreatitis.Study registered at ClinicalTrials.gov (NCT01085747). © Georg Thieme Verlag KG Stuttgart · New York.

  2. Treatment of Benign and Malignant Tracheobronchial Obstruction with Metal Wire Stents: Experience with a Balloon-Expandable and a Self-Expandable Stent Type

    International Nuclear Information System (INIS)

    Rieger, Johannes; Hautmann, Hubert; Linsenmaier, Ulrich; Weber, Cristoph; Treitl, Markus; Huber, R.M.; Pfeifer, Klaus-Juergen

    2004-01-01

    Over the last few years various types of metal wire stents have been increasingly employed in the treatment of both malignant and benign tracheobronchial obstruction. To date, however, few studies have investigated the in vivo properties of different stent types. We implanted 26 balloon-expandable tantalum Strecker stents (18 patients) and 18 self-expandable Wallstents (16 patients) into the tracheobronchial system of 30 patients with combined stenting in 4 patients. Mean age was 51 years (range: 0.5-79 years). Malignant disease was present in 23 patients, benign disease in seven patients. Both patients and individual stents were monitored clinically and radiographically. The probability of stents remaining within the tracheobronchial system, and of their remaining undislocated and uncompressed was calculated using Kaplan-Meier analysis for both stent types. Average stent follow-up time was 112 days until explantation and 115 days until patients' death or discharge. Kaplan-Meier analysis revealed a higher probability for the Wallstent to remain within the tracheobronchial system. Dislocation and compression occurred more rarely. Explantation, however, if desired, was more difficult compared to the Strecker stent. The Wallstent also led to the formation of granulation tissue, especially at the proximal stent end, frequently requiring reintervention. Both stent types proved to be effective therapeutic options in the management of obstructive tracheobronchial disease. The mechanical properties of the Strecker stent seem to be less favorable compared to the Wallstent but removal is easy. For benign disease, however, the Wallstent reveals limitations due to significant side effects

  3. Dysphagia with malignant stricture of esophagogastric junction: treatment with self-expandable nitinol stent

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Oh, Joo Hyeong; Yoon, Yup

    1995-01-01

    To evaluate the effectiveness, patency and safety of a self-expandable nitinol stent for palliative treatment of malignant stricture of gastroesophageal junction. An esophageal stent was inserted in five consecutive patients with malignant stricture of esophagogastric junction. Histologically, four cases were adenocarcinoma, and one was squamous cell carcinoma. The location and severity of stricture were evaluated with gastrografin just before stent insertion. In one patient with past subtotal gastrectomy, esophagography revealed fistulous fract at stricture site. No technical failure or procedural complications occurred, and improvement of dysphagia was noted in all patients soon after stent insertion. On follow up esophagograms performed 3 to 7 days after stent insertion, all stents were completely expanded and unchanged in positions. In one patient with fistulous connection at stricture site, esophagogram immediately after the procedure revealed complete occlusion of the fistula. Three patients died within 4, 7 and 8 consecutive months after stent insertion. Two patients are alive maintaining adequate body weight and passing most diet. Seft-expandable nitinol stent with it's good longitudinal flexibility and efficient radial force was effective in the palliative treatment of dysphagia in patient with malignant stricture at esophagogastric junction

  4. Dysphagia with malignant stricture of esophagogastric junction: treatment with self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyeong; Yoon, Yup [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-02-15

    To evaluate the effectiveness, patency and safety of a self-expandable nitinol stent for palliative treatment of malignant stricture of gastroesophageal junction. An esophageal stent was inserted in five consecutive patients with malignant stricture of esophagogastric junction. Histologically, four cases were adenocarcinoma, and one was squamous cell carcinoma. The location and severity of stricture were evaluated with gastrografin just before stent insertion. In one patient with past subtotal gastrectomy, esophagography revealed fistulous fract at stricture site. No technical failure or procedural complications occurred, and improvement of dysphagia was noted in all patients soon after stent insertion. On follow up esophagograms performed 3 to 7 days after stent insertion, all stents were completely expanded and unchanged in positions. In one patient with fistulous connection at stricture site, esophagogram immediately after the procedure revealed complete occlusion of the fistula. Three patients died within 4, 7 and 8 consecutive months after stent insertion. Two patients are alive maintaining adequate body weight and passing most diet. Seft-expandable nitinol stent with it's good longitudinal flexibility and efficient radial force was effective in the palliative treatment of dysphagia in patient with malignant stricture at esophagogastric junction.

  5. Insertion of a self-expandable metallic stent in canine lacrimal Sac : a long-term evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Sung, Kyu Bo; Yoon, Hyun Ki [Univ. of Ulsan, Ulsan (Korea, Republic of). College of Medicine; Kwon, Soon Tae [Chungnam National Univ., Taejon (Korea, Republic of). Medical School; Lee, Ho Jung; Lee, In Chul; Kim, Tae Hyung; Park, Sang Soo; Huh, Soo Jin [Univ. of Ulsan, Ulsan (Korea, Republic of). College of Medicine

    1998-01-01

    To evaluate the feasibility and long-term outcome of the use of self-expandable metallic Z-stents in the canine lacrimal sac. Stent placement was technically successful and well tolerated in all but one lacrimal sac, in which the stent was misplaced. At three and six months after stent placement, stent wires were not encased by epithelium, but at nine months, and one, two and three years after placement, six of the 12 stents had become encased in a proliferation of this where the stent wires contacted the lacrimal sac wall. In no lacrimal system in which stent placement had been successful was migration, stenosis or obstruction of the lacrimal system observed. One misplaced stent caused obstruction of the lacrimal sac, however . In 11 of 12 case (92%), fluoroscopic placement of an expandable metallic stent in the canine lacrimal sac was successful: in 6 of 8 cases (75%), the stent wires became encased by a proliferation of mucosa, but during long-term follow-up of 9 months to 3 years, no obstruction was observed. (author). 20 refs., 1 tab., 5 figs.

  6. Insertion of a self-expandable metallic stent in canine lacrimal Sac : a long-term evaluation

    International Nuclear Information System (INIS)

    Song, Ho Young; Sung, Kyu Bo; Yoon, Hyun Ki; Kwon, Soon Tae; Lee, Ho Jung; Lee, In Chul; Kim, Tae Hyung; Park, Sang Soo; Huh, Soo Jin

    1998-01-01

    To evaluate the feasibility and long-term outcome of the use of self-expandable metallic Z-stents in the canine lacrimal sac. Stent placement was technically successful and well tolerated in all but one lacrimal sac, in which the stent was misplaced. At three and six months after stent placement, stent wires were not encased by epithelium, but at nine months, and one, two and three years after placement, six of the 12 stents had become encased in a proliferation of this where the stent wires contacted the lacrimal sac wall. In no lacrimal system in which stent placement had been successful was migration, stenosis or obstruction of the lacrimal system observed. One misplaced stent caused obstruction of the lacrimal sac, however . In 11 of 12 case (92%), fluoroscopic placement of an expandable metallic stent in the canine lacrimal sac was successful: in 6 of 8 cases (75%), the stent wires became encased by a proliferation of mucosa, but during long-term follow-up of 9 months to 3 years, no obstruction was observed. (author). 20 refs., 1 tab., 5 figs

  7. Mechanical characteristics of self-expandable metallic stents: in vitro study with three types of stress

    International Nuclear Information System (INIS)

    Lee, Byung Hee; Kim, Kie Hwan; Chin, Soo Yil

    1998-01-01

    To obtain objective and comparable data for mechanical characteristics of self-expandable metallic stents widely used in the treatment of biliary obstruction. The stents tested were the 6 and 8 mm-band Hanaro spiral stent, Gianturco-Rosch Z stent, Wallstent, Ultraflex stent, and Memotherm stent. Each was subjected to three types of load:point, area, and circular. We analyzed their mechanical characteristics (resistance force, expansile force, and elasticity) according to these three types of stress. With regard to point loads, the Memotherm stent showed the highest resistance force and expansile force. The 8 mm-band Hanaro stent showed the lowest resistance force and the Gianturco-Rosch Z stent and Ultraflex stent showed lower expansile force. With regard to area loads, the Ultraflex stent showed the highest resistance force. The 6 mm-band Hanaro stent, Gianturco-Rosch Z stent, and Ultraflex stent showed higher expansile force. The 8 mm-band Hanaro stent showed the lowest value in both resistance force and expansile force. For circular loads, the Memotherm stent showed the highest resistance force and the Ultraflex stent and Wallstent showed lower value. Under all types of stress, the Hanaro stent and Memotherm stent were completely elastic, and the Ultraflex stent and Wallstent showed a wide gap between resistance force and expansile force. In clinical practice, awareness of the mechanical characteristics of each stent might help in choosing the one which is most suitable, according to type of biliary obstruction. =20

  8. Mechanical characteristics of self-expandable metallic stents: in vitro study with three types of stress

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Hee; Kim, Kie Hwan; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1998-09-01

    To obtain objective and comparable data for mechanical characteristics of self-expandable metallic stents widely used in the treatment of biliary obstruction. The stents tested were the 6 and 8 mm-band Hanaro spiral stent, Gianturco-Rosch Z stent, Wallstent, Ultraflex stent, and Memotherm stent. Each was subjected to three types of load:point, area, and circular. We analyzed their mechanical characteristics (resistance force, expansile force, and elasticity) according to these three types of stress. With regard to point loads, the Memotherm stent showed the highest resistance force and expansile force. The 8 mm-band Hanaro stent showed the lowest resistance force and the Gianturco-Rosch Z stent and Ultraflex stent showed lower expansile force. With regard to area loads, the Ultraflex stent showed the highest resistance force. The 6 mm-band Hanaro stent, Gianturco-Rosch Z stent, and Ultraflex stent showed higher expansile force. The 8 mm-band Hanaro stent showed the lowest value in both resistance force and expansile force. For circular loads, the Memotherm stent showed the highest resistance force and the Ultraflex stent and Wallstent showed lower value. Under all types of stress, the Hanaro stent and Memotherm stent were completely elastic, and the Ultraflex stent and Wallstent showed a wide gap between resistance force and expansile force. In clinical practice, awareness of the mechanical characteristics of each stent might help in choosing the one which is most suitable, according to type of biliary obstruction. =20.

  9. Transcatheter aortic value implantation with self-expandable nitinol valved stent: an experimental study in sheep

    International Nuclear Information System (INIS)

    Jiang Haibin; Huang Xinmiao; Bai Yuan

    2011-01-01

    Objective: to determine the feasibility and safety of transcatheter aortic valve implantation with domestic self-expandable nitinol valved stent in experimental sheep. Methods: A fresh pig pericardium was cross-linked with a 0.6% glutaraldehyde solution for 36 hours and then sutured on a nitinol self-expandable stent. Ten healthy sheep of (46.00±2.60) kg body weight were chosen for the study. Under general anesthesia, the device was delivered through catheter into the native aortic valve of the sheep via the femoral artery or abdominal aorta. The animals were followed up for three months. Results: Six devices were successfully delivered at the desired position in six sheep with no occurrence of complications. Angiographic and hemodynamic studies confirmed that the stents were fixed at correct position with competent valve function immediately and 90 days after the procedure. Technical failure or fatal complications occurred in the remaining four sheep. Conclusion: Implantation of a domestic nitinol self-expandable stent at the aortic valve position through a transcatheter approach is feasible in experimental sheep. (authors)

  10. Impact of peri-stent remodeling on restenosis: a volumetric intravascular ultrasound study.

    Science.gov (United States)

    Nakamura, M; Yock, P G; Bonneau, H N; Kitamura, K; Aizawa, T; Tamai, H; Fitzgerald, P J; Honda, Y

    2001-05-01

    Vessel remodeling is an important mechanism of late lumen loss after nonstent coronary interventions. However, its impact on in-stent restenosis has not been systematically investigated. Serial volumetric intravascular ultrasound analyses (poststent and follow-up) were performed in 55 lesions treated with a balloon-expandable stent (ACS MultiLink) using standard stent deployment techniques. The vessel volume (VV), lumen volume (LV), and volume bordered by the stent (SV) were measured using Simpson's method. The volume of plaque and neointima outside the stent (peri-stent volume, PSV) and volume of neointima within the stent (intrastent volume) were also measured. The change of each parameter during the follow-up period (follow-up minus poststent) was calculated and then divided by SV to normalize these values (designated as percent change [%]). As expected, %PSV directly correlated with %VV (Pexterior to a coronary stent occurs to a variable degree after stent implantation. There is a distinct trade-off between positive remodeling and in-stent hyperplasia: in segments in which the degree of peri-stent remodeling is less, intrastent neointimal proliferation is greater and accompanied by more significant late lumen loss.

  11. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    Science.gov (United States)

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Clinical outcomes between different stent designs with the same polymer and drug: comparison between the Taxus Express and Taxus Liberte stents.

    Science.gov (United States)

    Son, Jang-Won; Kim, Ung; Park, Jong-Seon; Kim, Young-Jo; Jang, Jae-Sik; Yang, Tae-Hyun; Kim, Dong-Soo; Kim, Dong-Kie; Seol, Sang-Hoon; Kim, Doo-Il; Nam, Chang-Wook; Hur, Seung-Ho; Kim, Kwon-Bae

    2013-01-01

    The Taxus Liberte stent (Boston Scientific Co.) evolved from the Taxus Express stent, with enhanced stent deliverability and uniform drug delivery. This study was designed to compare angiographic and clinical outcomes in real-world practice between the Taxus Liberte and Taxus Express stents. Between 2006 and 2008, 240 patients receiving the Taxus Liberte stent at three centers were registered and compared to historical control patients who had received the Taxus Express stent (n = 272). After propensity score matching, 173 patients treated with the Taxus Liberte stent and the same number of patients treated with the Taxus Express stent were selected. The primary outcome was a composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), ischemia driven target vessel revascularization (TVR), and stent thrombosis (ST) at 1 year. An additional angiographic assessment was conducted at 9 to 12 months. The study showed no significant difference between the Taxus Express and Taxus Liberte stents (death, 1.73% vs. 2.31%, p = 1.000; MI, 0% vs. 1.73%, p = 0.2478; TVR, 2.31% vs. 1.16%, p = 0.6848; and ST, 0% vs. 1.16%, p = 0.4986). The total MACE rate at 1 year did not differ between the groups (4.05% in Taxus Express vs. 4.05% in Taxus Liberte, p = 1.000). In addition, the binary restenosis rate did not differ (2.25% in Taxus Express vs. 1.80% in Taxus Liberte, p = 0.6848). In real-world experience with the two Taxus stent designs, both stents showed similarly good clinical and angiographic outcomes at 1 year. A long-term follow-up study is warranted.

  13. Self-expandable nitinol stent placement in homocysteinemic porcine aorta

    Directory of Open Access Journals (Sweden)

    Luís Henrique Gil França

    2008-01-01

    Full Text Available PURPOSE: To compare aortic intimal thickening of normal and hyperhomocysteinemic pigs (induced with a methionine-rich diet following placement of a self-expanding nitinol stent. METHODS: Eighteen Macau pigs were used. They were older than eight weeks in age and had an average weight of 30 kg. Pigs were randomly divided into two groups. The first, Group C (control, was fed a regular diet, and the second group, Group M, was fed a methionine-rich diet for 30 days to induce hyperhomocysteinemia. The self-expandable nitinol stents were 25mm in length and 8 mm in diameter after expansion. Blood samples were collected to measure total cholesterol, triglycerides, HDL and homocysteine concentrations. All animals were subjected to angiography. Thirty days after the procedure, the animals were sacrificed, and the abdominal aorta was removed for histological and digital morphometry analysis. RESULTS: Under microscopic evaluation, the intima was significantly thicker in Group C than in Group M. When groups were compared by digital morphometric analysis, intimal thickening of the vessel wall was higher in Group C than in Group M. There was no significant change in total cholesterol, triglycerides or HDL concentrations in either group. In group C the levels of plasma homocysteine ranged from 14,40 to 16,73µmol/l; in Group M, plasma homocysteine levels ranged from 17.47 to 59.80 µmol/l after 30 days of a methionine-rich diet. CONCLUSION: Compared to normal pigs, less intimal hyperplasia was observed in the abdominal aortas of hyperhomocysteinemic pigs thirty days after the insertion of a self-expandable nitinol stent.

  14. Acute stent recoil and optimal balloon inflation strategy: an experimental study using real-time optical coherence tomography.

    Science.gov (United States)

    Kitahara, Hideki; Waseda, Katsuhisa; Yamada, Ryotaro; Otagiri, Kyuhachi; Tanaka, Shigemitsu; Kobayashi, Yuhei; Okada, Kozo; Kume, Teruyoshi; Nakagawa, Kaori; Teramoto, Tomohiko; Ikeno, Fumiaki; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2016-06-12

    Our aim was to evaluate stent expansion and acute recoil at deployment and post-dilatation, and the impact of post-dilatation strategies on final stent dimensions. Optical coherence tomography (OCT) was performed on eight bare metal platforms of drug-eluting stents (3.0 mm diameter, n=6 for each) during and after balloon inflation in a silicone mock vessel. After nominal-pressure deployment, a single long (30 sec) vs. multiple short (10 sec x3) post-dilatations were performed using a non-compliant balloon (3.25 mm, 20 atm). Stent areas during deployment with original delivery systems were smaller in stainless steel stents than in cobalt-chromium and platinum-chromium stents (pstrategies showed a significant impact on final stent expansion.

  15. Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

    International Nuclear Information System (INIS)

    Riga, Celia V.; Bicknell, Colin D.; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-01-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  16. Modelling and simulating in-stent restenosis with complex automata

    NARCIS (Netherlands)

    Hoekstra, A.G.; Lawford, P.; Hose, R.

    2010-01-01

    In-stent restenosis, the maladaptive response of a blood vessel to injury caused by the deployment of a stent, is a multiscale system involving a large number of biological and physical processes. We describe a Complex Automata Model for in-stent restenosis, coupling bulk flow, drug diffusion, and

  17. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    Energy Technology Data Exchange (ETDEWEB)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro [Kyoto Second Red Cross Hospital, Kyoto (Japan)

    2012-02-15

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  18. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    International Nuclear Information System (INIS)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro

    2012-01-01

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  19. Metallic stent for the treatment of iliac arterial stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Chung, Jin Wook; Han, Joon Koo; Suh, Chul Soo; Yoo, Jae Wook; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of); Song, Chi Sung [Seoul City Boramae Hospital, Seoul (Korea, Republic of)

    1993-07-15

    In order to study the clinical efficacy of the metallic stent of the treatment of iliac arterial stenosis, the clinical and arteriographic findings of the 8 patients were retrospectively reviewed. All 8 patients were males with an age of 51 to 79. The Fontaine class for the functional status of lower extremities was II in 4 patients, III in 3 patents and IV in 1 patient. Self expandable Gianturco stent was inserted of in 7 iliac arteries and balloon expandable Palmaz stent was inserted in 2 iliac arteries in the 8 patients. The indications for the metallic stent application were localized dissection with significant residual stenosis in 6 sites, recoiling due to calcification in one case and eccentricity of the stenosislesionin 2 sites. The deployment of the metallic stent was successful in all the cases to maintain the patency of iliac arteries with residual stenosis less than 30%. The Fontaine class was improved to 1 in 6 patients, IIa in 1 patient and IIb in another one. During the follow up period of 3 to 14 month, none except one developed recurrence of the symptom. On the basis of our experience, we believe that metallic stent is safe and effective for the treatment of iliac arterial stenosis. However, we think that it is a complementary measure to the percutaneous transluminal angioplasty. The comparative study between different types of metallic stent and the long term effect should be investigated further.

  20. Experimental Evaluation of a New Single Wire Stainless Steel Fishscale Coronary Stent (Freedomª).

    Science.gov (United States)

    Wang; Verbeken; Mukherjee; Zhou; De Scheerder IK

    1996-10-01

    Recent randomized clinical trials revealed a significant reduction in angiographic restenosis rates when adjunctive stenting was performed after conventional coronary balloon angioplasty. Current approved coronary stents are however hampered by their rigidity, limiting their trackability in tortuous vessels and furthermore, needing high pressure deployment for optimal vessel apposition. New coronary stents are currently under development, using more biocompatible metal alloys and/or designs which better align to the vessel wall at moderate deployment pressures. We evaluated the safety, efficacy, angiographic and histological effect of a new stainless steel fishscale designed stent (Freedomª, Global Therapeutics, Co., USA) in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 20 pigs. Control angiograms at 6 weeks follow-up demonstrated patent vessels and morphologic evaluation showed only a mild fibromuscular neointimal response resulting in an area stenosis of 28.7 +/- 0.18% and a mean neointimal hyperplasia of 0.18 +/- 0.25 mm. Comparison with the Palmaz-Schatzª coronary stent in a porcine peripheral artery model demonstrated similar quantitative angiographic and morphologic vessel analysis results. Also the morphometric data were comparable. Area stenosis: Palmaz-Schatz: 37 +/- 0.24%, Freedom: 21 +/- 0.14%, p = 0.07. Mean neointimal hyperplasia: Palmaz-Schatz: 0.33 +/- 0.24 mm, Freedom: 0.18 +/- 0.08 mm, p = 0.08. CONCLUSION: Freedom coronary stent implantation in a porcine model resulted in a high procedural success without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six weeks histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia.

  1. Midterm to long-term safety and efficacy of self-expandable nitinol stent implantation for coarctation of aorta in adults.

    Science.gov (United States)

    Haji Zeinali, Ali Mohammad; Sadeghian, Mohammad; Qureshi, Shakeel A; Ghazi, Payam

    2017-09-01

    Endovascular treatment of coarctation of aorta (CoA) by self-expandable Nitinol stents is one of the recognized treatment methods and may be an alternative to surgery or balloon-expandable stent implantation for CoA but there is little information about midterm to long term results of self-expandable stents. Sixty-two patients with CoA (40 men), with a mean age of 30.7 ± 11 years, (range 17-63 years) underwent stent implantation with Optimed self-expandable Nitinol stents between 2005 and 2014. Successful outcome was defined as peak systolic pressure gradient ≤20 mmHg after stent implantation. The patients were followed-up clinically and by echocardiography and in patients, in whom there was suspicion of recoarctation, CT angiography or recatheterization was performed. 65 stents were successfully implanted in all 62 patients. Peak systolic pressure gradient decreased from mean 62.4 ± 18 mmHg (range 35-100 mmHg) to mean 2.8 ± 5 mmHg (range 0-15 mmHg; P Stent displacement occurred in 3 patients during the procedure. These were managed successfully by an overlapping second stent. None of the patients had major complications such as aortic dissection, rupture, or vascular access problems. In follow up, only three patients had recoarctation, and two of these were managed successfully by balloon redilation or further stenting 16 and 18 months after the first procedure and one patient refused reintervention. There were two deaths, unrelated to the procedure, 12 and 78 months after the initial intervention. Follow-up of a mean of 45.5 ± 17 months (range 12-105 months) demonstrated no evidence of aneurysm formation or stent fracture. Self-expandable nitinol stents for the treatment of native and recurrent CoA is safe and has good efficacy with acceptable midterm to long-term outcome. © 2017 Wiley Periodicals, Inc.

  2. Malignant inferior vena cava obstruction involving right atrium. Palliative treatment with self expandable metallic stent

    International Nuclear Information System (INIS)

    Shao Guoliang; Wang Jianhua; Zhou Kangrong; Yan Zhiping

    2001-01-01

    Objective: To investigate the safety and efficacy of placement of self-expandable metallic stent within right atrium and inferior vena cava (ICV) in patients with malignant ICV obstruction involving right atrium. Methods: There were 5 male patients with advanced hepatocellular carcinoma, aged from 42 to 65 years (mean 56.3 years). The malignancies invaded right atrium and ICV simultaneously, and caused obstruction of ICV. These patients presented symptoms and signs of obstruction of ICV such as hepatomegaly, ascites, edema of lower extremities. 'Z' type stainless steel stents (7.5-10.0 cm in length and 2.5 cm in diameter) were selected for these patients. Part (1.0-3.0 cm in length) of stent was placed in right atrium and the rest was in ICV. Results: All of stents were placed successfully and obstructed ICV reopened. The symptoms of obstruction of ICV relieved or disappeared. There were no recurrence of symptoms of obstruction of ICV and any cardiac complication related to placement of stents in follow-up period (67-188 days). Conclusion: Placement of self-expandable metallic stent within right atrium and ICV in treatment of patients with malignant ICV obstruction involving right atrium is one of the safe and effective methods

  3. Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)

    Science.gov (United States)

    de Jaegere, P; Mudra, H; Figulla, H; Almagor, Y; Doucet, S; Penn, I; Colombo, A; Hamm, C; Bartorelli, A; Rothman, M; Nobuyoshi, M; Yamaguchi, T; Voudris, V; DiMario, C; Makovski, S; Hausmann, D; Rowe, S; Rabinovich, S; Sunamura, M; van Es, G A

    1998-08-01

    A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. The study was designed to be multicentred, prospective, and observational. One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8

  4. Influence of stent design and use of protection devices on outcome of carotid artery stenting: a pooled analysis of individual patient data.

    Science.gov (United States)

    Wodarg, Fritz; Turner, Elisabeth L; Dobson, Joanna; Ringleb, Peter A; Mali, Willem P; Fraedrich, Gustav; Chatellier, Gilles; Bequemin, Jean-Pierre; Brown, Martin M; Algra, Ale; Mas, Jean-Louis; Jansen, Olav; Bonati, Leo H

    2018-04-19

    Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)

    2014-05-28

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  6. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    International Nuclear Information System (INIS)

    Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Wang, Chao-Jan; Liu, Shih-Jung; Hung, Kuo-Chun

    2014-01-01

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  7. Self-Expanding Nitinol Renal Artery Stents: Comparison of Safety and Efficacy of Bare Versus Polyzene-F Nanocoated Stents in a Porcine Model

    International Nuclear Information System (INIS)

    Kurz, P.; Stampfl, U.; Christoph, P.; Henn, C.; Satzl, S.; Radeleff, B.; Berger, I.; Richter, G. M.

    2011-01-01

    Objective: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. Materials and Methods: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. Results: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% ± 8.43% at 12 weeks in BNS versus 39.77% ± 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 ± 1.17 versus 2.17 ± 0.85 in BNS. The results for vessel wall injury (0.6 ± 0.58 for Polyzene-F-coated stents; 0.72 ± 0.98 for BNS) and re-endothelialization, (1.16 ± 0.43 and 1.23 ± 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. Conclusion: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies (≥120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.

  8. Use of Self-Expanding Metallic Ureteral Stents in the Secondary Treatment of Ureteral Stenosis Following Kidney Transplantation.

    Science.gov (United States)

    Xu, Guibin; Li, Xun; He, Yongzhong; Zhao, Haibo; Yang, Weiqing; Xie, Qingling

    2015-10-01

    To evaluate the safety and efficacy of self-expanding metal stents in the treatment of ureteral stenosis following kidney transplantation. Seven patients who developed benign stenosis after kidney transplantation were treated by a self-expanding metallic stent implantation from June 2007 to March 2014. All patients had undergone at least one open surgical procedure and one endourologic procedure for treatment of the stenosis. The extent of stenosis varied from 1.2 to 3.7 cm. Ultrasonography, urography, diuretic renography, and urine culture were performed every 3 months after stent insertion. Ureteroscopic examination was performed when needed. Stent placement was technically effective in all cases. The mean operative time was 37 minutes (range, 26-59 minutes). Lower urinary-tract symptoms and the ipsilateral flank pain were common early-stage complications and were greatly relieved after an average of 3 months. The mean follow-up duration was 38 months (range, 13-86 months), and no stent migration or fragmentation was observed. Urothelial hyperplasia occurred in only one patient and was effectively managed with a Double-J stent. Five patients had normal stable renal function; the remaining two had impaired renal function, including one patient with a preoperative renal failure who required dialysis at the end of the follow-up period (36 months). As an alternative to open surgery, implantation of a self-expanding metal stent is a safe and effective treatment for ureteral stenosis in patients who have undergone kidney transplantation.

  9. Conformable covered versus uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction: a randomized prospective study.

    Science.gov (United States)

    Lim, Sun Gyo; Kim, Jin Hong; Lee, Kee Myung; Shin, Sung Jae; Kim, Chan Gyoo; Kim, Kyung Ho; Kim, Ho Gak; Yang, Chang Heon

    2014-07-01

    A conformable self-expandable metallic stent was developed to overcome the limitation of previous self-expandable metallic stents. The aim of this study was to evaluate outcomes after placement of conformable covered and uncovered self-expandable metallic stents for palliation of malignant gastroduodenal obstruction. A single-blind, randomized, parallel-group, prospective study were conducted in 4 medical centres between March 2009 and July 2012. 134 patients with unresectable malignant gastroduodenal obstruction were assigned to a covered double-layered (n=66) or uncovered unfixed-cell braided (n=68) stent placement group. Primary analysis was performed to compare re-intervention rates between two groups. 120 patients were analysed (59 in the covered group and 61 in the uncovered group). Overall rates of re-intervention were not significantly different between the two groups: 13/59 (22.0%) in the covered group vs. 13/61 (21.3%) in the uncovered group, p=0.999. Stent migration was more frequent in the covered group than in the uncovered group (p=0.003). The tumour ingrowth rate was higher in the uncovered group than in the covered group (p=0.016). The rates of re-intervention did not significantly differ between the two stents. Conformable covered double-layered and uncovered unfixed-cell braided stents were associated with different patterns of stent malfunction. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Role of fluoroscopic guided self expandable metallic stents in the management of malignant esophageal strictures

    OpenAIRE

    Mohamed Shaker; Ahmed Deif; Amr Abdelaal

    2016-01-01

    Objectives: To evaluate the role of fluoroscopic guided self expanding metallic stents in the management of dysphagia caused by malignant esophageal strictures. Materials and methods: During the period between April 2010 and October 2012, 31 patients with malignant esophageal strictures were subjected to fluoroscopic guided self expanding metallic stent application. The study included 22 males and 9 females ranging in age between 22 and 75 years old with mean age of 56.8 years. Lesions wer...

  11. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  12. Understanding the requirements of self-expandable stents for heart valve replacement : radial force, hoop force and equilibrium

    NARCIS (Netherlands)

    Cabrera, M.S.; Oomens, C.W.J.; Baaijens, F.P.T.

    2017-01-01

    A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a

  13. Comparison of devices used for stent-assisted coiling of intracranial aneurysms.

    Directory of Open Access Journals (Sweden)

    Benjamin Izar

    Full Text Available INTRODUCTION: Two self-expandable stents, the Neuroform and the Enterprise stent, are widely used for stent-assisted coiling (SAC of complex shaped intracranial aneurysms. However, comparative knowledge about technical feasibility, peri- and post-procedural morbidity and mortality, packing densities as well as follow-up data is limited. MATERIAL AND METHODS: We conducted a retrospective study to investigate differences in aneurysms stented with the Enterprise or Neuroform stents. Angiographic follow-up (mean 19.42 months was available in 72.6% (61/84 of aneurysms treated with stent-assisted coiling. We further sought to compare stent-assisted coiling to a matched patient population with aneurysms treated by conventional coil embolization. RESULTS: The stenting success rate of the Enterprise was higher compared to the Neuroform stent (46/48 and 42/51, respectively. In 5 of 9 cases in which the Neuroform stent was not navigable to the landing zone, we successfully deployed an Enterprise stent instead. Eventually, 42 aneurysms were coiled after stenting in each group. We observed no significant differences in peri-procedural complication rate, post-procedural hospital stay, packing density, recurrence rate or number of in-stent stenosis. Strikingly, 36.1% of followed aneurysms in the SAC group showed progressive occlusion on angiographic follow-up imaging. The packing density was significantly higher in aneurysms treated by SAC as compared to conventionally coiled aneurysms, while recanalization rate was significantly lower in the SAC group. CONCLUSION: The procedural success rate is higher using the Enterprise, but otherwise both stents exhibited similar characteristics. Lower recurrence frequency and complication rates comparable to conventional coil embolization emphasize the importance of stent-assisted coiling in the treatment of complex aneurysms. Progressive occlusion on angiographic follow-up was a distinct and frequent observation in the

  14. Development of a dynamic in vitro model of a stented blood vessel to evaluate the effects of stent strut material selection and surface coating on smooth muscle cell response

    Science.gov (United States)

    Winn, Bradley Huegh

    Cardiovascular disease is the leading cause of mortality in The United States and Europe, accounting for approximately half of all deaths. The most common form of cardiovascular disease is atherosclerosis, which is characterized by the formation of fatty atheromatous plaques that can grow to occlude the vessel lumen, thus causing ischemia distal to the occlusion. This is commonly treated using balloon angioplasty, which is usually done in conjunction with the deployment of a stent. Stent deployment helps hold the vessel open following the local injury caused by balloon inflation and prevents elastic recoil and subsequent negative remodeling. Stenting has been shown to significantly reduce restenosis rates from approximately 20-50% without a stent to about 10-30% with stent deployment. However, restenosis still remains the main cause of long-term stent failure. In basic terms, a balloon angioplasty procedure is a forceful displacement of an atherosclerotic lesion serving to widen the vessel lumen to increase blood flow. This procedure causes stretching of the vessel wall, tears in the atherosclerotic plaques, and general damage to the vessel in turn signaling a complex cascade of thrombosis, inflammation, intimal thickening, and vascular remodeling. Stent deployment also further complicates the immunological response by triggering a foreign body response from the implantation of a biomaterial into the body. When performing an angioplasty procedure, particularly in conjunction with stent deployment, a certain degree of vascular injury is inevitable. However, the initial injury can be further complicated by the body's local reaction to the implanted biomaterial, the severity of which can ultimately dictate the degree of restenosis and subsequently affect procedural success. The proliferative response of VSMCs to the various afore mentioned stimuli results in the formation of often copious amounts of neointimal tissue, generally known as intimal hyperplasia. The

  15. Self-Deploying, Composite Habitats, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Cornerstone Research Group, Inc. (CRG), proposes to develop self-deploying, composite structures for lunar habitats, based on CRG's VeritexTM materials. These...

  16. A new approach to improve the local compressive properties of PPDO self-expandable stent.

    Science.gov (United States)

    Zhao, Fan; Xue, Wen; Wang, Fujun; Yu, Chenglong; Xu, Haiyan; Hao, Yi; Wang, Lu

    2017-04-01

    The radial performance of bioabsorbable polymeric intravascular stents is extremely important in assessing the efficiency of these devices in expanding narrow lumen, reducing stent recoil, and recovering to their original states after suffering from pulsating pressure. However, these stents remain inferior to metallic stents. Several thermal treatment conditions (60°C, 80°C, and 100°C for 1h) were investigated to improve the characteristics of poly(p-dioxanone) (PPDO) self-expandable stents. The local compressive force, stiffness, and viscoelasticity of these stents were also evaluated. Wide-angle X-ray diffraction and different scanning calorimetry measurements were performed to evaluate the recrystalline and thermodynamic changes of molecular chains. The declining conformer entropy of PPDO monofilaments was examined via energy analysis. The untreated stents had compressive modules of 514.80±70.59mN/mm, which was much higher than those of 80°C and 100°C treated stents (332.35±66.08mN/mm and 394.31±64.71mN/mm, respectively). Nevertheless, 100°C annealing stents had less stress relaxation and prior elastic recovery rate of 82.32±3.43mN and 92.55±1.61%, respectively, showing a much better shape stability than untreated stents (139.51±16.67mN and 86.18±3.57%, respectively). These findings present important clinical implications in the stent manufacturing process and warrant further study to develop new bioabsorbable stents with outstanding clinical efficacy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Application of Y-shaped, coated self-expandable metallic stents for anastomotic stenosis after gastrojejunostomy (Billroth II).

    Science.gov (United States)

    Li, Teng-Fei; Wu, Gang; Han, Xin-Wei; Shui, Shao-Feng; Ren, Jian-Zhuang; Li, Zhen; Ren, Ke-Wei

    2017-01-01

    Anastomotic stenosis is an infrequent but life-threatening complication after gastrojejunostomy (Billroth II). Tubular or single tubular stents have limited efficacy due to the particular anatomy. To assess the feasibility of a Y-shaped, fully-coated, self-expandable, metallic stent (SEMS) for anastomotic stenosis after gastrojejunostomy (Billroth II). Between January 2008 and August 2014, 14 patients (10 with gastric carcinoma and four with duodenal ulcers) had anastomotic stenoses following Billroth II reconstructions. Eight patients with gastric cancer had tumor recurrence near the anastomosis; two had benign strictures. The four duodenal ulcer patients had benign stenoses. An integrated Y-shaped, fully coated SEMS was designed to accord with the anatomy of residual gastrojejunal anastomotic strictures. Fourteen stents were inserted under fluoroscopic control. Follow-up was at 1, 3, 9, and 12 months, and then annually. All 14 stents were inserted successfully at the first attempt with a technical success rate of 100%. After stenting, abdominal symptoms resolved in all patients. All patients were followed up for 4-27 months (mean, 13.9 months). One of the eight recurrent cases died of multiple tumor metastases and liver failure after 7 months, without obstruction symptoms. In all six patients with benign anastomotic stenosis, the stents were removed successfully without complication and with no evidence of restenosis based on clinical evaluation and imaging. A Y-shaped, fully-coated SEMS proved to be a feasible and minimally invasive procedure for treating anastomotic stenosis after gastrojejunostomy (Billroth II). © The Foundation Acta Radiologica 2016.

  18. Self-expandable metallic stent placement plus laparoscopy for acute malignant colorectal obstruction.

    Science.gov (United States)

    Zhou, Jia-Min; Yao, Li-Qing; Xu, Jian-Min; Xu, Mei-Dong; Zhou, Ping-Hong; Chen, Wei-Feng; Shi, Qiang; Ren, Zhong; Chen, Tao; Zhong, Yun-Shi

    2013-09-07

    To investigate the clinical advantages of the stent-laparoscopy approach to treat colorectal cancer (CRC) patients with acute colorectal obstruction (ACO). From April 2008 to April 2012, surgery-related parameters, complications, overall survival (OS), and disease-free survival (DFS) of 74 consecutive patients with left-sided CRC presented with ACO who underwent self-expandable metallic stent (SEMS) placement followed by one-stage open (n = 58) or laparoscopic resection (n = 16) were evaluated retrospectively. The stent-laparoscopy group was also compared with a control group of 96 CRC patients who underwent regular laparoscopy without ACO between January 2010 and December 2011 to explore whether SEMS placement influenced the laparoscopic procedure or reduced long-term survival by influencing CRC oncological characteristics. The characteristics of patients among these groups were comparable. The rate of conversion to open surgery was 12.5% in the stent-laparoscopy group. Bowel function recovery and postoperative hospital stay were significantly shorter (3.3 ± 0.9 d vs 4.2 ± 1.5 d and 6.7 ± 1.1 d vs 9.5 ± 6.7 d, P = 0.016 and P = 0.005), and surgical time was significantly longer (152.1 ± 44.4 min vs 127.4 ± 38.4 min, P = 0.045) in the stent-laparoscopy group than in the stent-open group. Surgery-related complications and the rate of admission to the intensive care unit were lower in the stent-laparoscopy group. There were no significant differences in the interval between stenting and surgery, intraoperative blood loss, OS, and DFS between the two stent groups. Compared with those in the stent-laparoscopy group, all surgery-related parameters, complications, OS, and DFS in the control group were comparable. The stent-laparoscopy approach is a feasible, rapid, and minimally invasive option for patients with ACO caused by left-sided CRC and can achieve a favorable long-term prognosis.

  19. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  20. Do expandable metallic airway stents have a role in the management of patients with benign tracheobronchial disease?

    Science.gov (United States)

    Madden, Brendan P; Loke, Tuck-Kay; Sheth, Abhijat C

    2006-07-01

    With increasing availability many centers are deploying expandable metallic stents to manage patients with diverse endobronchial disorders. Although these devices have an important role in malignant disease their usefulness in benign large airway disorders is less defined. Between 1997 and 2005, 31 patients aged 34 to 83 years with benign large airway compromise secondary to tracheomalacia (n = 7), posttracheostomy stricture (n = 8), posttracheostomy rupture (n = 2), postpneumonectomy bronchopleural fistula (n = 2), stricture after lung transplantation (n = 3), lobectomy, tuberculosis, traumatic injury to right main bronchus (n = 1 patient each), and external compression of the airway secondary to achalasia, multinodular goiter, aortic aneurysm, right brachiocephalic artery aneurysm, right interrupted aortic arch, and dissecting aneurysm (n = 1 patient each) who were medically unfit for formal surgical intervention were treated by Ultraflex stent deployment. The range of follow-up was 1 week to 96 months. Stents were deployed under anesthesia using rigid bronchoscopy. Complications included granulation tissue formation (n = 11) treated with Nd: YAG laser ablation, stent migration (n = 1; stent removed, another deployed), metal fatigue (n = 1), stent removal (n = 1), mucus plugging (n = 2), and halitosis (n = 6) difficult to treat despite antibiotics. Thirteen patients died of unrelated causes between 1 week and 15 months after stent deployment. Endobronchial metallic stents should be considered only for selected patients with large airway compromise secondary to benign airway diseases for whom other medical comorbidities contraindicate formal airway surgery. Once deployed, they are difficult to remove, are associated with significant complications, and require prospective bronchoscopic surveillance and often further therapeutic intervention.

  1. Remote Systems Design & Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, Sharon A.; Baker, Carl P.; Valdez, Patrick LJ

    2009-08-28

    The Pacific Northwest National Laboratory (PNNL) was tasked by Washington River Protection Solutions, LLC (WRPS) to provide information and lessons learned relating to the design, development and deployment of remote systems, particularly remote arm/manipulator systems. This report reflects PNNL’s experience with remote systems and lays out the most important activities that need to be completed to successfully design, build, deploy and operate remote systems in radioactive and chemically contaminated environments. It also contains lessons learned from PNNL’s work experiences, and the work of others in the national laboratory complex.

  2. Outcome of self-expanding metal stenting followed by radiation therapy for unresectable extrahepatic bile duct cancer

    International Nuclear Information System (INIS)

    Jin Jing; Gao Li; Yu Zihao; Han Jianzhu; Zhai Renyou

    2007-01-01

    Objective: To retrospectively analyze the efficacy for self-expanding metal stenting followed by radiation therapy for unresectable extrahepatic bile duct cancer. Methods: From Jan 1996 to Sep 2002, 17 patients were treated with self-expanding metal stenting followed by Ir 192 high dose brachytherapy (brachytherapy group, n=5)and by external beam radiation therapy(external radiation therapy group, n=9). Brachytherapy was delivered on the same day or the following day after stenting with the total dose of DT 20- 30 Gy, twice daily, for 2-3 days. The median total dosage of external radiation therapy was 48 Gy (14-66 Gy), 2 Gy/fraction. Results: Jaundice was released after metal stenting from 71.4% to 14.3% (P=0.001), showing no significant difference between brachytherapy and external radiation therapy in terms of jaundice release(χ 2 =0.21, P=0.65). The median survival period(5-35 months)for whole groups was 12 months 1-, 2-year survival rates were 40.8% and 8.16%, respectively. No significant difference was shown for patients received either brachytherapy or external radiation therapy for 8 months, but with 1,2 year survival rate as 40.0%, 13.3%, respectively (χ 2 =1.10, P=0.29). Conclusions: Self-expanding metal stenting is able to release jaundice significantly and followed by high dose radiation therapy may further prolong the survival. (authors)

  3. Percutaneous treatment of adult isthmic aortic coarctation: acute and long-term clinical and imaging outcome with a self-expandable uncovered nitinol stent.

    Science.gov (United States)

    Kische, Stephan; D'Ancona, Giuseppe; Stoeckicht, Yannik; Ortak, Jasmin; Elsässer, Albrecht; Ince, Hüseyin

    2015-01-01

    To present perioperative and long-term results of percutaneous treatment of adult isthmic coarctation of the aorta by means of a self-expandable closed-web uncovered nitinol stent (Sinus-XL, Optimed, Esslingen, Germany). Preoperative, perioperative, and long-term clinical and computed tomographic angiography data were collected and analyzed prospectively. A total of 52 consecutive patients were treated with the Sinus-XL stent. Mean age was 36.6 (21-67) years, peak invasive trans-coarctation of the aorta gradient was 54.7 ± 9.9 mm Hg, and upper body hypertension unresponsive to medical treatment was present in all patients. Mean stent diameter and length were 24.2 mm (22-28 mm) and 70.4 mm (40-80 mm), respectively. Eight patients (15.4%) required coarctation of the aorta predilatation. All patients underwent poststent dilatation with a noncompliant balloon. Postoperative peak gradient (3.3 ± 2.5 mm Hg) was reduced significantly (P stent collapse and secondary migration and documented stability in aortic diameter (18.3 ± 2.7 mm). Thirty patients (57.7%) were completely weaned-off antihypertensive medications and their use dropped from 2.6 to 0.9 drugs/patient (P self-expandable uncovered stent is safe and durable. The peculiar stent design maintains adequate localized radial strength over time with minimal trauma on the adjacent aortic wall and negligible device-related complications. Blood pressure control optimization is immediate and persistent even at long-term follow-up. © 2015 American Heart Association, Inc.

  4. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.

    Science.gov (United States)

    Rafighdust, Abbasali; Eshraghi, Ali

    2015-10-27

    The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.

  5. Analysis of the placement of multiple metallic stents in the treatment of hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Lu Zaiming; Liang Hongyuan; Guo Qiyong; Wen Feng; Liu Zhaoyu; Zhang Jun

    2007-01-01

    Objective: To evaluate the clinical efficacy of multiple stents placement in the management of hilar cholangiocarcinoma, especially in the complex cases of which the hepatic ducts are invaded. Methods: Forty-five consecutive patients with hilar cholangiocarcinoma were treated with percutaneous transhepatic placement of two or three self-expandable metallic endoprostheses. The cause of hilar obstructions in these patients were all cholangiocarcinoma, including Bismuth classification type II (n 12), IIIa (n 17), IIIb (n 10), and IV (n 6). Two or 3 stents were placed in the configuration of T, Y or X over the strictures. Results: Stent placement with 2 or 3 endoprostheses was successful in all patients. All patients showed significant decrease in serum bilirubin level. The mortality rate within 30 days of stent placement was 2.2% (1/45). The mean survival and stent patency times were 215.3 d (26- 516 d) and 181.5 d (26-473 d), respectively. Conclusion: Deploying of multiple metallic stents is an effective method to treat complex hilar cholangiocarcinoma, especially for the cases of which hepatic ducts are invaded; the hepatic ducts should be drained as much as possible. (authors)

  6. Role of Self-Expandable Metal Stents in Acute Variceal Bleeding

    Directory of Open Access Journals (Sweden)

    Fuad Maufa

    2012-01-01

    Full Text Available Acute variceal bleeding continues to be associated with significant mortality. Current standard of care combines hemodynamic stabilization, antibiotic prophylaxis, pharmacological agents, and endoscopic treatment. Rescue therapies using balloon tamponade or transjugular intrahepatic portosystemic shunt are implemented when first-line therapy fails. Rescue therapies have many limitations and are contraindicated in some cases. Placement of fully covered self-expandable metallic stent is a promising therapeutic technique that can be used to control bleeding in cases of refractory esophageal bleeding as an alternative to balloon tamponade. These stents can be left in place for as long as two weeks, allowing for improvement in liver function and institution of a more definitive treatment.

  7. Endoscopic stenting as bridge-to-surgery (BTS) in left-sided obstructing colorectal cancer: Experience with conformable stents.

    Science.gov (United States)

    Parodi, Andrea; De Ceglie, Antonella; De Luca, Luca; Conigliaro, Rita; Naspetti, Riccardo; Arpe, Paola; Coccia, Gianni; Conio, Massimo

    2016-11-01

    Compared to emergency surgery, self-expandable metallic stents are effective and safe when used as bridge-to-surgery (BTS) in operable patients with acute colorectal cancer obstruction. In this study, we report data on the new conformable colonic stents. To evaluate clinical effectiveness of conformable stents as BTS in patients with acute colorectal cancer obstruction. This was a retrospective study. The study was conducted at six Italian Endoscopic Units. Data about patients with acute malignant colorectal obstruction were collected between 2007 and 2012. All patients were treated with conformable stents as BTS. Technical success, clinical success, rate of primary anastomosis and colostomy, early and late complications were evaluated. Data about 88 patients (62 males) were reviewed in this study. Conformable SEMS were correctly deployed in 86 out of 88 patients, with resolution of obstruction in all treated patients. Tumor resection with primary anastomosis was possible in all patients. A temporary colostomy was performed in 40. Early complications did not occur. Late complications occurred in 11 patients. Stent migration was significantly higher in patients treated with partially-covered stents compared to the uncovered group (35% vs. 0%, P<0.001). Endoscopical re-intervention was required in 12% of patients. One patient with rectal cancer had an anastomotic dehiscence after surgery and he was successfully treated with endoscopic clipping. One year after surgery, all patients were alive and local recurrence have not been documented. This was a retrospective and uncontrolled study. Preliminary data from this large case series are encouraging, with a high rate of technical and clinical success and low rate of clinically relevant complications. Partially-covered SEMS should be avoided in order to reduce the risk of endoscopic re-intervention. Copyright © 2016. Published by Elsevier Masson SAS.

  8. The implantation of separating aortic stent-graft into the canine thoracic aorta: an experimental study

    International Nuclear Information System (INIS)

    Xia Jinguo; Shi Haibin; Yang Zhengqiang; Li Chao; Liu Sheng; Zu Qingquan; Li Linsun

    2011-01-01

    Objective: to assess the technical feasibility of implanting separating stent-graft into the canine thoracic aorta and to study its biocompatibility. Methods: Twelve adult dogs were randomly and equally divided into three groups. The right femoral artery was cut open, through which the separating stent-graft was inserted and deployed in the canine thoracic aorta, with the proximal end of the graft being quite close to the origin of the left subclavian artery. the technical feasibility of the deployment process was assessed. Angiography was performed at 4, 8 and 12 weeks after stent-graft placement to evaluate the position and patency of the stent-graft. Then the dogs were sacrificed and the specimens were collected for pathologic study. Both gross and microscopic examinations were made to evaluate the fixation of the stent-graft with the vessel wall, the endothelialization of stent-graft surface and the pathologic changes of the vascular wall. Results: A total of ten separating stent-grafts were successfully deployed in the canine thoracic aorta, no migration or deformation occurred. One dog died of massive bleeding due to the rupture of the right femoral artery which occurred when the delivery system containing the inner bare stent was inserted through the right femoral artery. Death occurred in another dog as a result of the ascending aorta rupture caused by the migration of outer-layer stent-graft. Angiography was conducted at 4, 8 and 12 weeks after stent-graft placement. No migration, deformation, rupture or stenosis of the implanted stent-grafts were observed. The formation of intima on the inner surface of the bare stent appeared at 4 weeks, which became more and more obvious with the time passing, and at 12 weeks complete endothelialization of stent-graft surface was observed. Conclusion: Technically, it is feasible to deploy the separating aortic stent-graft into the canine thoracic aorta. Moreover, the separating aortic stent-graft carries excellent

  9. Self-Expanding Metal Stents Improve Swallowing and Maintain Nutrition During Neoadjuvant Therapy for Esophageal Cancer.

    Science.gov (United States)

    Smith, Zachary L; Gonzaga, Jason E; Haasler, George B; Gore, Elizabeth M; Dua, Kulwinder S

    2017-06-01

    Patients with locally advanced esophageal cancer can have significant dysphagia. Nutritional support during neoadjuvant therapy is often delivered via nasoenteric or percutaneous feeding tubes. These approaches do not allow for per-oral feeding. Evaluate the safety and efficacy of fully covered self-expanding metal esophageal stents for nutritional support during neoadjuvant therapy. This was a pilot, prospective study at a single tertiary center. From March 2012 to May 2013, consecutive patients with esophageal cancer eligible for neoadjuvant therapy were enrolled. Metal stents were placed prior to starting neoadjuvant therapy. Data were collected at baseline and predetermined intervals until an endpoint (surgery or disease progression). Outcomes included dysphagia grade, satisfaction of swallowing score, nutritional status (weight, serum albumin), impact on surgery, and adverse events. Fourteen stents were placed in 12 patients (59.1 ± 9.5 years, 11 men, 1 woman). Dysphagia grade (pre 3.4 ± 0.5 vs post 0.2 ± 0.4, p esophageal cancer, self-expanding metal stents are safe and effective in relieving dysphagia and maintaining nutrition. They allow patients to eat orally, thereby improving patient satisfaction. The presence of an in situ stent did not interfere with surgery.

  10. Self-expandable metallic stent placement for patients with inoperable esophageal carcinoma. Investigation of the influence of prior radiotherapy and chemotherapy

    International Nuclear Information System (INIS)

    Ihara, Yuko; Murayama, Sadayuki; Toita, Takafumi; Utsunomiya, Takashi; Nagata, Osamu; Akamine, Tamaki; Ogawa, Kazuhiko; Adachi, Genki; Tanigawa, Noboru

    2006-01-01

    The aim of this study was to evaluate the efficacy and complications of self-expandable metallic stent placement for patients with inoperable esophageal carcinoma after radiotherapy and/or chemotherapy. We obtained data from 19 patients with advanced or recurrent esophageal carcinoma between 1996 and 2000. In all patients, a self-expandable metallic stent was placed under fluoroscopic guidance. Dysphagia before and after stent placement was graded. Complications after stent placement were also evaluated. Data were compared between patients with and without prior radiotherapy and/or chemotherapy. The procedure was technically successful in all but one patient. The dysphagia grade improved in all patients. No life-threatening complications occurred. The other major complications such as mediastinitis occurred in two patients, and pneumonia and funnel phenomenon occurred in one patient each. These patients had a history of radiotherapy and/or chemotherapy prior to stent placement. Eight of the twelve patients with prior radiotherapy and/or chemotherapy compared with one of seven patients without prior therapy had persistent chest pain, which was a statistically significant difference (P<0.05). Placement of self-expandable metallic stents was effective for patients with advanced or recurrent esophageal carcinoma. However, prior irradiation and/or chemotherapy increased the risk of persistent chest pain after stent placement. (author)

  11. Short-term results of self-expanding metal stents for acute malignant large bowel obstruction

    DEFF Research Database (Denmark)

    Kobborg, M; Broholm, M; Frostberg, E

    2017-01-01

    AIM: Self-expanding metal stents (SEMSs) can be used as a palliative treatment or to initially decompress colon prior to definitive surgery (as a so-called 'bridge to surgery'). The purpose of this study was to investigate the efficacy and safety of SEMS used as palliation and bridge to surgery...... for malignant large bowel obstruction. METHOD: A multicentre retrospective study was conducted from January 2010 to December 2013 to identify patients undergoing stent placement for acute large bowel obstruction. Patients were included from four Danish colorectal centres. Outcomes identified included clinical...... success, 30-day mortality, stent related complications and surgery related complications. Furthermore, we analysed for predictive factors for successful stenting. Clinical success was defined as relief of obstructive symptoms, without the need of other additional surgical interventions during the hospital...

  12. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents

    Directory of Open Access Journals (Sweden)

    Jing Lin

    2016-02-01

    Full Text Available Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  13. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

    Science.gov (United States)

    Lin, Jing; Guidoin, Robert; Du, Jia; Wang, Lu; Douglas, Graeham; Zhu, Danjie; Nutley, Mark; Perron, Lygia; Zhang, Ze; Douville, Yvan

    2016-02-16

    Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  14. Pilot study of a novel, large-bore, fully covered self-expandable metallic stent for unresectable distal biliary malignancies.

    Science.gov (United States)

    Mukai, Tsuyoshi; Yasuda, Ichiro; Isayama, Hiroyuki; Iwashita, Takuji; Itoi, Takao; Kawakami, Hiroshi; Kogure, Hirofumi; Nakai, Yousuke

    2016-09-01

    In patients with unresectable malignant distal biliary obstruction, covered self-expandable metallic stents (CSEMS) may remain patent longer than uncovered self-expandable metallic stents as a result of tumor ingrowth prevention. One main cause of recurrent biliary obstruction (RBO) in CSEMS is sludge formation, which can be prevented using a large-bore stent. Therefore, we developed a novel, 12-mm diameter fully covered SEMS (FCSEMS) and investigated its clinical safety, efficacy, and rate of adverse events. This prospective, multicenter pilot study, which ran between June 2011 and November 2012, included 38 consecutive patients with unresectable malignant distal biliary obstruction. All patients underwent endoscopic insertion of our novel stent. Primary endpoint was non-RBO rate 6 months after placement. Technical and functional success rates of the procedures were 100%. Six-month non-RBO rate was 50%, and median time to RBO was 184 days. Median survival time was 241 days. Twelve patients died within 6 months after stent placement without RBO. RBO was observed in 10 patients (26%), with seven experiencing stent occlusion and three experiencing stent migration. Adverse events other than RBO (at Stent removal for reintervention was successfully completed in eight patients. Our novel FCSEMS may be safe and effective for managing malignant distal obstruction with an acceptable incidence of adverse events. © 2016 Japan Gastroenterological Endoscopy Society.

  15. Flexibility and trackability of laser cut coronary stent systems.

    Science.gov (United States)

    Szabadíts, Péter; Puskás, Zsolt; Dobránszky, János

    2009-01-01

    Coronary stents are the most important supports in present day cardiology. Flexibility and trackability are two basic features of stents. In this paper, four different balloon-expandable coronary stent systems were investigated mechanically in order to compare their suitability. The coronary stent systems were assessed by measurements of stent flexibility as well as by comparison of forces during simulated stenting in a self-investigated coronary vessel model. The stents were cut by laser from a single tube of 316L stainless steel or L-605 (CoCr) cobalt chromium alloy. The one-and four-point bending tests were carried out to evaluate the stent flexibility E x I (Nmm(2)), under displacement control in crimped and expanded configurations. The flexibility of stents would be rather dependent on the design than on raw material. In general a more flexible stent needs lower tracking force during the implantation. The L-605 raw material stents need lower track force to pass through in the vessel model than the 316L raw material stents. The sort and long stents passed through the curved vessel model in different ways. The long stents nestled to the vessel wall at the outer arc and bent, while the short stents did not bend in the curve, only the delivery systems bent.

  16. Broncho-vascular fistulas from self-expanding metallic stents: A retrospective case review

    Directory of Open Access Journals (Sweden)

    Chirag Choudhary

    2013-01-01

    Full Text Available To highlight a potentially fatal complication of broncho-vascular fistula arising from the self expanding metallic stent (SEMS placement. We retrospectively analyzed five patients with benign and malignant airway diseases, who developed tracheo/broncho-vascular fistulas following SEMS placement in our tertiary care setting. All patients received either Wallstent or Ultraflex® stent (Boston Scientific, Natick, MA between 1999 and 2007. All patients had received adjunct therapy such as balloon bronchoplasty, laser therapy or electrocautery. Most patients presented with massive hemoptysis. A total of 483 SEMS were placed during this period. SEMS placement can be complicated by Broncho-vascular fistula formation. True incidence and precise time interval between the insertion of stent and onset of this complication is unknown. Additional therapeutic modalities to maintain stent patency may enhance the risk of fistula formation. SEMS should only be used in a select sub-group of patients, after exhaustive evaluation of other treatment options. These cases provide evidence that broncho-vascular fistulas can develop at any time following SEMS placement, suggesting the need for a more cautious approach, especially while using them for a long term management. In benign airway disease, the stent should be removed as soon as healing has taken place.

  17. Medical impulsive therapy (MIT): the impact of 1 week of preoperative tamsulosin on deployment of 16-French ureteral access sheaths without preoperative ureteral stent placement.

    Science.gov (United States)

    Kaler, Kamaljot S; Safiullah, Shoaib; Lama, Daniel J; Parkhomenko, Egor; Okhunov, Zhamshid; Ko, Young H; Huynh, Linda; Patel, Roshan M; Landman, Jaime; Clayman, Ralph V

    2018-05-25

    Medical expulsive therapy is based on pharmacologic ureteral relaxation. We hypothesized this concept may facilitate the deployment of the large 16 French (F) ureteral access sheath (UAS) when patients are intentionally pre-treated with oral tamsulosin, i.e., medical impulsive therapy. We retrospectively analyzed our experience with UAS deployment during endoscopic-guided percutaneous nephrolithotomy in prone position in patients pre-treated for 1 week with oral tamsulosin with a contemporary untreated cohort. Between January 2015 and September 2016, seventy-seven patients without a pre-existing ureteral stent met inclusion criteria. Demographic data, tamsulosin usage, UAS size, deployment failure, ureteral injuries, stone-free rates, and complications were recorded. Univariate and multivariate analysis was conducted to assess the impact of tamsulosin on deployment of the 16F UAS. There was no statistical difference between the tamsulosin (n = 40) group and non-tamsulosin (n = 37) group in regard to demographic data. The tamsulosin group had a significantly higher percentage of 16F UAS deployment, 87 vs. 43% (p < 0.001), and no significant difference in ureteral injuries (p = 0.228). Univariate and multivariate analysis revealed that tamsulosin significantly increased the odds ratio (9.3 and 19.4, respectively) for successful passage of a 16F UAS. Despite a larger stone volume, there was no significant difference in computed tomography scan complete stone-free rates (29 vs. 42%; p = 0.277) at median post-operative time of only 3 days. In this retrospective study, 1 week of preoperative tamsulosin was associated with an increase in the deployment of a 16F UAS in patients without preoperative ureteral stent placement.

  18. Atrial septal stenting - How I do it?

    Directory of Open Access Journals (Sweden)

    Kothandam Sivakumar

    2015-01-01

    Full Text Available A wide atrial communication is important to maintain hemodynamics in certain forms of congenital and acquired heart defects. In comparison to balloon septostomy or blade septostomy, atrial septal stenting provides a controlled, predictable, and long-lasting atrial communication. It often needs a prior Brockenbrough needle septal puncture to obtain a stable stent position. A stent deployed across a previously dilated and stretched oval foramen or tunnel form of oval foramen carries higher risk of embolization. This review provides technical tips to achieve a safe atrial septal stenting. Even though this is a "How to do it article," an initial discussion about the indications for atrial septal stenting is vital as the resultant size of the atrial septal communication should be tailored for each indication.

  19. Supera self-expanding stents for endovascular treatment of femoropopliteal disease: a review of the clinical evidence

    Directory of Open Access Journals (Sweden)

    Bishu K

    2015-07-01

    Full Text Available Kalkidan Bishu,1,2 Ehrin J Armstrong1,21Division of Cardiology, University of Colorado, Aurora, 2Denver VA Medical Center, Denver, CO, USAAbstract: Femoropopliteal lesions account for a significant proportion of endovascular interventions for peripheral artery disease in patients with disabling claudication or chronic limb ischemia. The femoropopliteal artery crosses two joint structures (hip and knee joints and courses through the muscular adductor canal in the thigh, which places the artery at increased biomechanical stress. There is a critical need for stent platforms with a reduced risk of stent fracture while maintaining patency during long-term follow-up. The Supera peripheral stent system has a braided nickel–titanium alloy stent designed to withstand the unique stressors along the course of the femoropopliteal artery. This design may be associated with improved patency in association with reduced stent fracture rates on short- and medium-term follow-up. Further studies, including randomized controlled studies, comparing the Supera interwoven nickel–titanium alloy stent system with other stent platforms and angioplasty alone are needed.Keywords: peripheral artery disease, femoropopliteal atherosclerosis, SUPERA interwoven nitinol stent, stent fracture

  20. Rotational atherectomy ablation for an unexpandable stent under the guide of IVUS

    Science.gov (United States)

    Si, Daoyuan; Liu, Guohui; Tong, Yaliang; He, Yuquan

    2018-01-01

    Abstract Rationale: Inadequate stent expansion due to rigid calcified may result in restenosis lesions, but the available options are limited. Patient concerns: We report a case via the trans-radial approach of the severely underexpanded freshly deployed stent due to heavily calcified plaques Diagnoses: Coronary angiography revealed that there was no adequate expansion of the freshly deployed stent. Interventions: Under the guide of intravascular ultrasound (IVUS), rotational atherectomy (RA) successfully ablated the stent layers and the protruding calcified plaque. Followed by balloon angioplasty, the ablated segment was scaffolded with another stent, well expanded and documented by IVUS. Outcomes: The patient was uneventful during the procedure and remained angina free at the point of one year of clinical follow-up. Lessons: This case indicated that RA via the trans-radial approach could be a useful remedy in the situation of under-expansion of implanted stents, and the debulking should be performed under IVUS-guidance. PMID:29443790

  1. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-01-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-termmorbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD. PMID:29470746

  2. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance.

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-05-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-term morbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD.

  3. Y-shaped bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction: data from a referral center for palliative care.

    Science.gov (United States)

    Di Mitri, R; Mocciaro, F

    2014-01-01

    Malignant hilar strictures are a clinical challenge because of the current therapeutic approach and the poor prognosis. In recent years, self-expandable metallic stents have proven more effective than plastic stents for palliation of malignant hilar strictures, with the bilateral stent-in-stent technique registering a high success rate. We report our experience with Y-shaped endoscopic self-expandable metallic stents placement for treatment of advanced malignant hilar strictures. From April 2009 to August 2012, we prospectively collected data on patients treated with Y-shaped SEMS placement for advanced malignant hilar carcinoma. Data on technical success, clinical success, and complications were collected. Twenty patients (9 males) were treated (mean age 64.2 ± 15.3 years). The grade of malignant hilar strictures according to the Bismuth classification was II in 5 patients (25%), IIIa in 1 (5%), and IV in 14 (70%). The mean bilirubin level was 14.7 ± 4.9 mg/dL. Technical success was achieved in all patients, with a significant reduction in bilirubin levels (2.9 ± 1.7 mg/dL). One patient experienced cholangitis as early complication, while in 2 patients stent ingrowth was observed. No stents migration was recorded. There was no procedure-related mortality. At the end of the follow-up (7.1 ± 3.1 months), 13 of the 20 patients (65%) had died. Our experience confirms endoscopic bilateral self-expandable metallic stents placement with stent-in-stent technique (Y-shaped configuration) as a feasible, effective, and safe procedure for palliation of unresectable malignant hilar strictures.

  4. Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body: a case report

    Directory of Open Access Journals (Sweden)

    Kumagai Hozumi

    2012-09-01

    Full Text Available Abstract Introduction Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. Case presentation A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Conclusions Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient’s general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.

  5. Development of biodegradable magnesium alloy stents with coating

    Directory of Open Access Journals (Sweden)

    Lorenza Petrini

    2014-07-01

    Full Text Available Biodegradable stents are attracting the attention of many researchers in biomedical and materials research fields since they can absolve their specific function for the expected period of time and then gradually disappear. This feature allows avoiding the risk of long-term complications such as restenosis or mechanical instability of the device when the vessel grows in size in pediatric patients. Up to now biodegradable stents made of polymers or magnesium alloys have been proposed. However, both the solutions have limitations. The polymers have low mechanical properties, which lead to devices that cannot withstand the natural contraction of the blood vessel: the restenosis appears just after the implant, and can be ascribed to the compliance of the stent. The magnesium alloys have much higher mechanical properties, but they dissolve too fast in the human body. In this work we present some results of an ongoing study aiming to the development of biodegradable stents made of a magnesium alloy that is coated with a polymer having a high corrosion resistance. The mechanical action on the blood vessel is given by the magnesium stent for the desired period, being the stent protected against fast corrosion by the coating. The coating will dissolve in a longer term, thus delaying the exposition of the magnesium stent to the corrosive environment. We dealt with the problem exploiting the potentialities of a combined approach of experimental and computational methods (both standard and ad-hoc developed for designing magnesium alloy, coating and scaffold geometry from different points of views. Our study required the following steps: i selection of a Mg alloy suitable for stent production, having sufficient strength and elongation capability; ii computational optimization of the stent geometry to minimize stress and strain after stent deployment, improve scaffolding ability and corrosion resistance; iii development of a numerical model for studying stent

  6. The integrated place of tracheobronchial stents in the multidisciplinary management of large post-pneumonectomy fistulas: our experience using a novel customised conical self-expandable metallic stent.

    Science.gov (United States)

    Dutau, Hervé; Breen, David Patrick; Gomez, Carine; Thomas, Pascal Alexandre; Vergnon, Jean-Michel

    2011-02-01

    Stump dehiscence after pneumonectomy is a cause of morbidity and mortality in patients treated for non-small-cell lung carcinoma. Surgical repair remains the treatment of choice but can be postponed or contraindicated. Bronchoscopic techniques may be an option with curative intent or as a bridge towards definitive surgery. The aim of the study is to evaluate the efficacy and the outcome of a new customised covered conical self-expandable metallic stent in the management of large bronchopleural fistulas complicating pneumonectomies. A case series using chart review of non-operable patients presenting with large bronchopleural fistulas (>6mm) post-pneumonectomies as a definitive treatment with curative intent for non-small-cell lung carcinomas and requiring the use of a dedicated conical shaped stent in two tertiary referral centres. Seven patients presenting large post-pneumonectomy fistulas (between 6 and 12 mm) were included. Cessation of the air leak and clinical improvement was achieved in all the patients after stent placement. Stent-related complications (two migrations and one stent rupture) were successfully managed using bronchoscopic techniques in two patients and surgery in one. Mortality, mainly related to overwhelming sepsis, was 57%. Delayed definitive surgery was achieved successfully in three patients (43%). This case series assesses the short-term clinical efficacy of a new customised covered conical self-expandable metallic stent in the multidisciplinary management of large bronchopleural fistulas complicating pneumonectomies in patients deemed non-operable. Long-term benefits are jeopardised by infectious complications. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  7. EDITORIAL Wireless sensor networks: design for real-life deployment and deployment experiences Wireless sensor networks: design for real-life deployment and deployment experiences

    Science.gov (United States)

    Gaura, Elena; Roedig, Utz; Brusey, James

    2010-12-01

    Wireless sensor networks (WSNs) are among the most promising technologies of the new millennium. The opportunities afforded by being able to program networks of small, lightweight, low-power, computation- and bandwidth-limited nodes have attracted a large community of researchers and developers. However, the unique set of capabilities offered by the technology produces an exciting but complex design space, which is often difficult to negotiate in an application context. Deploying sensing physical environments produces its own set of challenges, and can push systems into failure modes, thus revealing problems that can be difficult to discover or reproduce in simulation or the laboratory. Sustained efforts in the area of wireless networked sensing over the last 15 years have resulted in a large number of theoretical developments, substantial practical achievements, and a wealth of lessons for the future. It is clear that in order to bridge the gap between (on the one hand) visions of very large scale, autonomous, randomly deployed networks and (on the other) the actual performance of fielded systems, we need to view deployment as an essential component in the process of developing sensor networks: a process that includes hardware and software solutions that serve specific applications and end-user needs. Incorporating deployment into the design process reveals a new and different set of requirements and considerations, whose solutions require innovative thinking, multidisciplinary teams and strong involvement from end-user communities. This special feature uncovers and documents some of the hurdles encountered and solutions offered by experimental scientists when deploying and evaluating wireless sensor networks in situ, in a variety of well specified application scenarios. The papers specifically address issues of generic importance for WSN system designers: (i) data quality, (ii) communications availability and quality, (iii) alternative, low-energy sensing

  8. Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases.

    Science.gov (United States)

    Tanisaka, Yuki; Ryozawa, Shomei; Kobayashi, Masanori; Harada, Maiko; Kobatake, Tsutomu; Omiya, Kumiko; Iwano, Hirotoshi; Arai, Shin; Nonaka, Kouichi; Mashimo, Yumi

    2018-02-01

    Covered self-expandable metallic stents (CSEMS) may provide palliative drainage for unresectable distal malignant biliary strictures. Laser-cut CSEMS allows easy positioning due to its characteristic of minimal stent shortening. Endoscopic stent removal is sometimes recommended for recurrent biliary obstruction (RBO). However, there are no previous reports of endoscopic removal of laser-cut CSEMS. The current study presents data from 6 patients who were placed a laser-cut CSEMS for unresectable distal malignant biliary strictures, and later endoscopic stent removal was attempted for RBO at the present institute. The duration of stent placement, the procedural success rate, the procedural duration, and accidental complications were evaluated. The mean duration of stent placement was 156±37.9 days (range, 117-205). The procedural success rate was 100%. The mean procedural duration was 11.8±7.5 min (range, 5-24). No complications were reported. Laser-cut CSEMS were safely removed from all patients. The present case report is the first to demonstrate that Endoscopic stent removal of laser-cut CSEMS was safely performed.

  9. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.

    Science.gov (United States)

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-01-01

    Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  10. Esophageal Stent for Refractory Variceal Bleeding: A Systemic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Xiao-Dong Shao

    2016-01-01

    Full Text Available Background. Preliminary studies suggest that covered self-expandable metal stents may be helpful in controlling esophageal variceal bleeding. Aims. To evaluate the effectiveness and safety of esophageal stent in refractory variceal bleeding in a systematic review and meta-analysis. Methods. A comprehensive literature search was conducted on PubMed, EMBASE, and Cochrane Library covering the period from January 1970 to December 2015. Data were selected and abstracted from eligible studies and were pooled using a random-effects model. Heterogeneity was assessed using I2 test. Results. Five studies involving 80 patients were included in the analysis. The age of patients ranged from 18 to 91 years. The mean duration of follow-up was 46.8 d (range, 30–60 d. The success rate of stent deployment was 96.7% (95% CI: 91.6%–99.5% and complete response to esophageal stenting was in 93.9% (95% CI: 82.2%–99.6%. The incidence of rebleeding was 13.2% (95% CI: 1.8%–32.8% and the overall mortality was 34.5% (95% CI: 24.8%–44.8%. Most of patients (87.4% died from hepatic or multiple organ failure, and only 12.6% of patients died from uncontrolled bleeding. There was no stent-related complication reported and the incidence of stent migration was 21.6% (95% CI: 4.7%–46.1%. Conclusion. Esophageal stent may be considered in patients with variceal bleeding refractory to conventional therapy.

  11. Effective treatment of benign biliary strictures with a removable, fully covered, self-expandable metal stent: A prospective, multicenter European study

    Science.gov (United States)

    Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin

    2016-01-01

    Background Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. Objective The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. Methods We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Results Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Conclusions Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months. PMID:28507752

  12. Effective treatment of benign biliary strictures with a removable, fully covered, self-expandable metal stent: A prospective, multicenter European study.

    Science.gov (United States)

    Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin; Caca, Karel

    2017-04-01

    Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months.

  13. Success and complications of an intra-ductal fully covered self-expanding metal stent (ID-FCSEMS) to treat anastomotic biliary strictures (AS) after orthotopic liver transplantation (OLT).

    Science.gov (United States)

    Aepli, Patrick; St John, Andrew; Gupta, Saurabh; Hourigan, Luke F; Vaughan, Rhys; Efthymiou, Marios; Kaffes, Arthur

    2017-04-01

    Anastomotic biliary strictures (AS) after orthotopic liver transplantation (OLT) belong to the most common biliary complications and cause the biggest morbidity burden after OLT. Metal stents for benign biliary strictures are gaining acceptance with many published series. Traditional metal stent designs seem to have poor durability in AS after OLT. Novel intra-ductal stents are showing promise in these strictures. As a result, we designed a special stent with an antimigration waist and a short stent length with a long removal string that rests in the duodenum for easy removal. This is a retrospective multi-centre Australian study of AS after OLT treated with a novel intra-ductal fully covered self-expanding metal stent. From August 2008 to October 2014, records from three liver transplant centres were reviewed. Totally 36 ID-FCSEMS were inserted in 31 cases to treat an AS after OLT. The mean age of the patients was 56 years, and 61 % were male. The mean time of AS presentation after OLT was 20.3 months. Eight out of our 31 patients were previously treated using multiple plastic stenting over time without any success. Treatment with the ID-FCSEMS was performed with an average treatment time of 3.8 months. Stricture resolution was achieved in 100 %. All attempted stents removals were successful without any difficulty. Complications were reported in 6.5 %. It was pleasing that only one case of stent migration (2.8 %) was seen. Follow-up showed seven cases of AS recurrence (24.1 %), and all were treated successfully with repeat ERCP and stenting (some metal, some plastic). This novel ID-FCSEMS has a high clinical success and low complication rate, and in particular, there was only one case of stent migration. As a result, this stent type is preferred to traditional metal stents for treating AS after OLT.

  14. The design of trachea-main bronchial covered embranchment stent and the primary clinical application

    International Nuclear Information System (INIS)

    Han Xinwei; Wu Gang; Gao Xuemei; Li Yongdong; Wang Yanli; Ma Nan

    2004-01-01

    Objective: To design the trachea-main bronchus covered embranchment stent and study the primary treatment for thoracostomach main bronchial fistula and main bronchial stenosis. Methods: The stent was designed on the bases of the peculiar anatomic structure and the pathological changes of thoracostomach-main bronchial fistula and main bronchial stenosis. Under the fluoroscopic guidance, implantations were carried out in thoracostomach-carina fistula 1 case thoracostomach-left main bronchial fistula 1, thoracostomach-right main bronchial fistula and left main bronchial stenosis 1 case, altogether with 5 stents. Results: Stents were placed successfully, not only improving the breathing and living quality but also completing the closure of the ora of the thoracostomach-airway fistula with further vanishing of the choke after drinking and eating together with the inhalation pneumonia. The bronchus became normal in a main bronchial stenosis after the stent was taken out. Conclusions: Trachea-main bronchial covered embranchment stent could be used to close thoracostomach-airway fistula and to treat main bronchial benign/malignant stenosis. The procedure is simple and safe. (authors)

  15. Y-Shaped Bilateral Self-Expandable Metallic Stent Placement for Malignant Hilar Biliary Obstruction: Data from a Referral Center for Palliative Care

    Directory of Open Access Journals (Sweden)

    R. Di Mitri

    2014-01-01

    Full Text Available Background and Aim. Malignant hilar strictures are a clinical challenge because of the current therapeutic approach and the poor prognosis. In recent years, self-expandable metallic stents have proven more effective than plastic stents for palliation of malignant hilar strictures, with the bilateral stent-in-stent technique registering a high success rate. We report our experience with Y-shaped endoscopic self-expandable metallic stents placement for treatment of advanced malignant hilar strictures. Methods. From April 2009 to August 2012, we prospectively collected data on patients treated with Y-shaped SEMS placement for advanced malignant hilar carcinoma. Data on technical success, clinical success, and complications were collected. Results. Twenty patients (9 males were treated (mean age 64.2 ± 15.3 years. The grade of malignant hilar strictures according to the Bismuth classification was II in 5 patients (25%, IIIa in 1 (5%, and IV in 14 (70%. The mean bilirubin level was 14.7 ± 4.9 mg/dL. Technical success was achieved in all patients, with a significant reduction in bilirubin levels (2.9 ± 1.7 mg/dL. One patient experienced cholangitis as early complication, while in 2 patients stent ingrowth was observed. No stents migration was recorded. There was no procedure-related mortality. At the end of the follow-up (7.1 ± 3.1 months, 13 of the 20 patients (65% had died. Conclusions. Our experience confirms endoscopic bilateral self-expandable metallic stents placement with stent-in-stent technique (Y-shaped configuration as a feasible, effective, and safe procedure for palliation of unresectable malignant hilar strictures.

  16. Chemotherapy versus self-expanding metal stent as primary treatment of severe dysphagia from unresectable oesophageal or gastro-oesophageal junction cancer.

    Science.gov (United States)

    Touchefeu, Yann; Archambeaud, Isabelle; Landi, Bruno; Lièvre, Astrid; Lepère, Céline; Rougier, Philippe; Mitry, Emmanuel

    2014-03-01

    To compare chemotherapy first (group 1) versus self-expanding metal stent first (group 2) for the management of malignant dysphagia in unresectable oesophageal or gastro-oesophageal junction cancer. Patients from two university hospitals with severe malignant dysphagia (dysphagia score ≥ 2) uneligible for surgery or radiochemotherapy were evaluated retrospectively. Forty-two patients were included in group 1, and 29 in group 2. After 4 weeks, dysphagia scores improved by at least 1 point in 67% of patients in group 1 versus 93% in group 2 (p=0.01); 48% of patients in group 1 were able to eat solid food versus 68% in group 2 (p=0.054). In group 1, a self-expanding metal stent was secondarily placed in 18 patients (42.9%), whereas in group 2 dysphagia required a second self-expanding metal stent placement in 33.3% of patients. Chemotherapy as the first treatment may be a valid option, avoiding self-expanding metal stent insertion in half of the patients. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Percutaneous transluminal angioplasty and stent placement for iliofemoral arterial atherosclerotic occlusive disease

    International Nuclear Information System (INIS)

    Zheng Yanbo; Jiang Wenjin; Liu Sheng; Song Xuepeng; Sheng Qirui

    2006-01-01

    Objectives: To assess the safety and efficacy of percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of iliofemoral arterial atherosclerotic occlusive diseases. Methods From April 1999 to August 2004, 13 cases of iliofemoral arterial occlusions were recanalized with contact thrombolytic therapy combined with guide wire mechanical recanalization method, followed by angioplasty and stent placement. A total of 25 self-expanding Wallstents were deployed. All patients were followed up by means of duplex ultrasound, angiography, or both. Results: All 13 cases were successfully recanalized, with technical successful rate of 100%. Available follow-up for all patients from 8 months-5 years (mean 26.2 months) included one patient undergoing again with successful contact thrombolysis because of early thrombosis; another patient with recurrent symptoms at 19 month after operation undertaking surgical bypass because of later reocclusion; all of the rest stents showing patency by the end of the study. Conclusions: Contact thrombolysis combined with guide wire mechanical recanalization for iliofemoral arterial occlusion is safe and effective, whereas PTA and stent placement would have the nearly same efficacy for the disease with mild injury and low restenosis. (authors)

  18. Safety and Efficacy of a Fully Covered Self-Expandable Metallic Stent in Benign Airway Stenosis.

    Science.gov (United States)

    Fortin, Marc; Lacasse, Yves; Elharrar, Xavier; Tazi-Mezalek, Rachid; Laroumagne, Sophie; Guinde, Julien; Astoul, Philippe; Dutau, Hervé

    2017-01-01

    The use of self-expandable metallic stents (SEMS) in benign airway disease was the object of a boxed warning from the United States Food and Drug Administration in 2005 due to the risk of stent-related complications and difficulties associated with their removal. Third-generation fully covered SEMS have been commercialized since this warning and theoretically should not present the same difficulties associated with removal as they cannot become embedded in the airway mucosa. We aimed to examine the safety and efficacy of a specific third-generation SEMS, the Silmet stent. We reviewed the records of all patients treated for benign airway stenosis with third-generation Silmet SEMS from January 2011 to December 2015 at the North Hospital of Marseilles, France. Forty SEMS were inserted in 30 patients over this period. Twenty (50.0%) stents were removed because of stent-related complications after a median of 77.0 ± 96.6 days (migration 32.5%, granulation tissue formation 7.5%, subjective intolerance 5.0%, mucus plugging 2.5%, laryngeal edema 2.5%). There were no cases of stent-related mortality. All complications were managed successfully endoscopically. Thirty-six stents (90.0%) were removed successfully after a median of 122.0 ± 113.2 days without any complications. The clinical success rate of stent treatment was 40.7%. Third-generation SEMS are a safe treatment option for complex benign airway stenosis, but complications requiring stent removal are frequent. Further studies are needed to compare the performance of third-generation SEMS and silicone stents in benign airway stenosis. © 2017 S. Karger AG, Basel.

  19. Safety and benefits of self-expandable metallic stents with chemotherapy for malignant gastric outlet obstruction.

    Science.gov (United States)

    Miyabe, Katsuyuki; Hayashi, Kazuki; Nakazawa, Takahiro; Sano, Hitoshi; Yamada, Tomonori; Takada, Hiroki; Naitoh, Itaru; Shimizu, Shuya; Kondo, Hiromu; Nishi, Yuji; Yoshida, Michihiro; Umemura, Shuichiro; Hori, Yasuki; Kato, Akihisa; Ohara, Hirotaka; Joh, Takashi

    2015-07-01

    The influence of chemotherapy on placement of self-expandable metallic stents (SEMS) for malignant gastric outlet obstruction (MGOO) has not been evaluated extensively. We investigated the influence of chemotherapy on the clinical outcomes of SEMS placement for MGOO. A total of 152 cancer patients with MGOO from a university hospital and affiliate hospitals were included. The patients were classified according to chemotherapy status and evaluated for palliative efficacy and safety of SEMS placement. Technical success rate, time to oral intake, and parameters indicating improvement of physical condition did not differ between the with- and without-chemotherapy groups after stent placement. Re-intervention and stent migration were significantly more frequent in the with-chemotherapy group than in the without-chemotherapy group after stent placement (re-intervention, 32.4% vs 7.8%, P = 0.0005; stent migration, 13.5% vs 1.7%, P = 0.0097). The frequency of adverse events did not differ between the with- and without-chemotherapy groups. Although chemotherapy after stent placement was an independent predictive factor for shortening the stent patency period (hazard ratio [HR], 3.10; P = 0.0264), the use of additional stents facilitated uneventful recovery and further prolonged survival time (HR, 0.60; P = 0.0132). Various cancer patients with MGOO can undergo SEMS placement safely regardless of chemotherapy, and concurrent chemotherapy after stent placement can prolong survival time, although re-intervention and stent migration may be increased. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  20. A new Nitinol stent for use in superior vena cava syndrome

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Midtgaard, Annette; Brenøe, Anne-Sofie

    2015-01-01

    AIM: The aim of the study was to assess the early clinical experience with the Zilver Vena stent in treating patients with malignant superior vena cava syndrome. METHODS: Demographic, procedural, and follow-up data of 12 patients (seven women; mean age 69 years) treated for superior vena cava...... syndrome with in all 21 Zilver Vena stents between March 2012 and October 2013 were retrospectively reviewed. All cavographies and contrast enhanced CT related to the treatment and during follow-up were evaluated and the patients had clinical follow-up until dead. They were all in terminal state...... at the time of stent deployment. RESULTS: All patients had superior vena cava obstruction and clinical superior vena cava syndrome caused by malignant expansive mediastinal disease (eight patients non-small cell lung cancer and four small cell lung cancer). The technical success with deployment of the stents...

  1. USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE

    Directory of Open Access Journals (Sweden)

    M. N. Kornilov

    2013-01-01

    Full Text Available Aim. The aim of this study focuses on the first experience with self-expandable stents, analysis of its efficacy and safety in the treatment of anastomotic strictures after liver transplantation. Materials and methods. There’re 136 liver transplantations performed from 2004 till 2012. To correct anastomotic strictures we’ve used only the self-expandable coated nitinol stent. We performed stenting in 7 recipient. Result. In 131 liver transplant recipients incidence of biliary strictures has been 5.3%. All of 5 patients have been managed by retrograde or antegrade way. Conclusion. Our first experience demonstrate efficacy and safety of the used tecniques up to 24 months. The analysis of more long-term results is required. 

  2. Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients-Can This Concept Work Out? A Single Center Experience Focusing on Stent Design.

    Science.gov (United States)

    Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan

    2014-12-01

    To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length  1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58-87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1-59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up.

  3. A method to determine the kink resistance of stents and stent delivery systems according to international standards

    Directory of Open Access Journals (Sweden)

    Brandt-Wunderlich Christoph

    2016-09-01

    Full Text Available The kink behavior of vascular stents is of particular interest for clinicians, stent manufacturers and regulatory as a kinked stent generates a lumen loss in the stented vessel and can lead to in-stent restenosis. In this study methods to determine the kink resistance of stents and stent delivery systems according to the ISO 25539-2 and FDA guidance no. 1545 were presented. The methods are applicable for balloon expandable stents as well as for self-expanding stents and determine the lumen loss and residual diameter change dependent on the specific bending radius.

  4. Covered versus uncovered self-expandable metal stents for malignant biliary strictures: A meta-analysis and systematic review.

    Science.gov (United States)

    Moole, Harsha; Bechtold, Matthew L; Cashman, Micheal; Volmar, Fritz H; Dhillon, Sonu; Forcione, David; Taneja, Deepak; Puli, Srinivas R

    2016-09-01

    Self-expandable metal stents (SEMS) are used for palliating inoperable malignant biliary strictures. It is unclear if covered metal stents are superior to uncovered metal stents in these patients. We compared clinical outcomes in patients with covered and uncovered stents. Studies using covered and uncovered metallic stents for palliation in patients with malignant biliary stricture were reviewed. Articles were searched in MEDLINE, PubMed, and Ovid journals. Fixed and random effects models were used to calculate the pooled proportions. Initial search identified 1436 reference articles, of which 132 were selected and reviewed. Thirteen studies (n = 2239) for covered and uncovered metallic stents which met the inclusion criteria were included in this analysis. Odds ratio for stent occlusion rates in covered vs. uncovered stents was 0.79 (95 % CI = 0.65 to 0.96). Survival benefit in patients with covered vs. uncovered stents showed the odds ratio to be 1.29 (95 % CI = 0.95 to 1.74). Pooled odds ratio for migration of covered vs. uncovered stents was 9.9 (95 % CI = 4.5 to 22.3). Covered stents seemed to have significantly lesser occlusion rates, increased odds of migration, and increased odds of pancreatitis compared to uncovered stents. There was no statistically significant difference in the survival benefit, overall adverse event rate, and patency period of covered vs. uncovered metal stents in patients with malignant biliary strictures.

  5. Novel 3D-CT evaluation of carotid stent volume: greater chronological expansion of stents in patients with vulnerable plaques.

    Science.gov (United States)

    Itami, Hisakazu; Tokunaga, Koji; Okuma, Yu; Hishikawa, Tomohito; Sugiu, Kenji; Ida, Kentaro; Date, Isao

    2013-09-01

    Although self-expanding carotid stents may dilate gradually, the degrees of residual stenosis have been quantified by the NASCET criteria, which is too simple to reflect the configuration of the stented artery. We measured the volumes of the stent lumens chronologically by 3D-CT in patients after carotid artery stenting (CAS), and analyzed the correlations between the volume change and medical factors. Fourteen patients with carotid artery stenosis were treated using self-expanding, open-cell stents. All patients underwent preoperative plaque MRI (magnetization-prepared rapid acquisition gradient-echo, MPRAGE) and chronological 3D-CT examinations of their stents immediately after their placement and 1 day, 1 week, and 1 month after the procedure. The volume of the stent lumen was measured using a 3D workstation. The correlations between stent volume and various factors including the presence of underlying diseases, plaque characteristics, and the results of the CAS procedure were analyzed. Stent volume gradually increased in each case and had increased by 1.04-1.55 (mean, 1.25)-fold at 1 postoperative month. The presence of underlying medical diseases, plaque length, the degree of residual stenosis immediately after CAS, and plaque calcification did not have an impact on the change in stent volume. On the other hand, the stent volume increase was significantly larger in the patients with vulnerable plaques that demonstrated high MPRAGE signal intensity (P stent volume. Self-expanding stents in carotid arteries containing vulnerable plaques expand significantly more than those without such plaques in a follow-up period.

  6. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    International Nuclear Information System (INIS)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja; Jung, Gyoo Sik

    2005-01-01

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  7. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja [College of Medicine, Kosin University, Busan (Korea, Republic of); Jung, Gyoo Sik [Ulsan Hospital, Ulsan (Korea, Republic of)

    2005-12-15

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  8. Novel deployment of a covered duodenal stent in open surgery to facilitate closure of a malignant duodenal perforation

    Directory of Open Access Journals (Sweden)

    Psaila Josephine

    2009-10-01

    Full Text Available Abstract Background Its a dilemma to attempt a palliative procedure to debulk the tumour and/or prevent future obstructive complications in a locally advanced intra abdominal malignancy. Case presentation A 38 year old Vietnamese man presented with a carcinoma of the colon which had invaded the gallbladder and duodenum with a sealed perforation of the second part of the duodenum. Following surgical exploration, it was evident that primary closure of the perforated duodenum was not possible due to the presence of unresectable residual tumour. Conclusion We describe a novel technique using a covered duodenal stent deployed at open surgery to aid closure of a malignant duodenal perforation.

  9. The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Alparslan, Burcu, E-mail: burcu.alparslan@gmail.com [Yozgat State Hospital, Radiology Clinic (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Uludag University Faculty of Medicine, Department of Radiology (Turkey); Eritmen, Ulku Turpcu, E-mail: drulkutur@hotmail.com.tr [Special Eregli Anatolia Hospital, Radiology Clinic (Turkey); Duran, Selcen, E-mail: selcenduran16@hotmail.com [Yerkoy State Hospital, Neurology Clinic (Turkey); Ozkaya, Guven, E-mail: ozkaya@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Biostatistics (Turkey); Hakyemez, Bahattin, E-mail: bhakyemez@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Radiology (Turkey)

    2016-04-15

    PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

  10. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    Science.gov (United States)

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  11. A Fast Placement Technique for Covered Tracheobronchial Stents in Patients with Complicated Esophagorespiratory Fistulas

    International Nuclear Information System (INIS)

    Kishi, Kazushi; Nakao, Taisei; Goto, Hironobu; Kimura, Masashi; Sonomura, Tetsuo; Yamanaka, Noboru; Nanjo, Kishio; Sato, Morio

    2005-01-01

    Purpose. To test an endotracheal placement procedure for malignant esophagorespiratory fistula when endoesophageal placement is inapplicable. Methods. We report on patients with malignant esophagorespiratory fistula to which endoesophageal approaches were complicated with a complete obstruction of the hypopharynx, a collapsible tracheobronchus, or a previously placed endoesophageal stents. Gore-Tex membrane-covered Z-stents were deployed in the trachea using a coaxial introducer system in three patients. A Dumon tube was deployed in the bronchus over the bronchofiberscope in one patient. Results. All fistula were completely sealed by the endotracheal or endobronchial stenting. Symptomatic and clinical improvements were immediate obtained. Conclusion. Endotracheal or endobronchial covered stent placement is thought to be an effective alternative method for sealing esophagorespiratory fistula

  12. Mechanical Properties of Metallic Stents: How Do These Properties Influence the Choice of Stent for Specific Lesions?

    International Nuclear Information System (INIS)

    Dyet, John F.; Watts, William G.; Ettles, Duncan F.; Nicholson, Anthony A.

    2000-01-01

    Purpose: To assess selected balloon-expandable and self-expanding stents for radial force, flexibility, radio-opacity, and trackability, and to relate these physical characteristics to potential indications for placement.Methods: Force-strain curves were plotted for each stent and the force required to produce 50% luminal narrowing was recorded. The ability of the stent to show elastic recoil following deformation was also noted. Flexibility was measured by bending the stents against a force transducer and recording the force required per degree of flexion. Radio-opacity was measured by comparing each stent against a standard aluminum step wedge. Trackability was measured by testing the ability of the stent on its delivery system to track over angles of 90 deg. and 60 deg. Results: The balloon-expandable stents showed greater radial strength and radio-opacity but, apart from the AVE Iliac Bridge stent, showed poorer flexibility and trackability. The self-expanding stents showed less radial force but were able to re-expand following deformity. They were generally more flexible and had better trackability but lower radio-opacity.Conclusion: There is no stent which exhibits all the ideal properties required and therefore the interventionist will need to keep a range of stents available if all lesions are to be addressed

  13. A compact self-recording pressure based sea level gauge suitable for deployments at harbour and offshore environments

    Digital Repository Service at National Institute of Oceanography (India)

    Desa, E.; Peshwe, V.B.; Joseph, A.; Mehra, P.; Naik, G.P.; Kumar, V.; Desa, E.S.; Desai, R.G.P.; Nagvekar, S.; Desai, S.P.

    A compact and lightweight self-recording pressure based sea level gauge has been designed to suit deployments from harbour and offshore environments. A novel hydraulic coupling device designed in-house was used to transfer the seawater pressure...

  14. Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.

    Science.gov (United States)

    Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto

    2015-08-01

    Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  15. Efficacy of Self-Expandable Metallic Stent Inserted for Refractory Hemorrhage of Duodenal Cancer

    Directory of Open Access Journals (Sweden)

    Takashi Orii

    2016-05-01

    Full Text Available Because of advances in the technology of gastrointestinal endoscopy and improvements in the quality of stents, it has become routine to place a stent as palliative therapy for malignant gastrointestinal obstruction. On the other hand, stent placement for malignant gastrointestinal hemorrhage has scarcely been reported, although it may be performed for hemorrhage of the esophageal varicose vein. We recently experienced a patient with refractory hemorrhage from an unresectable duodenal cancer who underwent placement of a self-expandable metallic stent (SEMS and thereafter had no recurrence of the hemorrhage. A 46-year-old man underwent laparotomy to radically resect a cancer in the third portion of the duodenum, which invaded widely to the superior mesenteric vein and its branches and was considered unresectable. After stomach-partitioning gastrojejunostomy was performed, chemotherapy was initiated according to the regimen of chemotherapy of far advanced gastric cancer. One year and 4 months after induction of chemotherapy, gastrointestinal hemorrhage occurred. Upper gastrointestinal endoscopy revealed the hemorrhage oozing from the duodenal cancer, and endoscopic hemostasis, such as injection of hypertonic saline epinephrine and argon plasma coagulation, was unsuccessful. Twenty days after emergence of the hemorrhage, an endoscopic covered SEMS was placed with confirmation by fluoroscopy. Immediately after placement of the stent, the tarry stool stopped and the anemia ceased to progress. The recurrence of the hemorrhage has not been confirmed without migration of the stent. SEMS is an effective hemostatic procedure for malignant refractory hemorrhage.

  16. Successful Expansion of an Underexpanded Stent by Rotational Atherectomy

    Science.gov (United States)

    Vales, Lori; Coppola, John; Kwan, Tak

    2013-01-01

    The current routine use of intracoronary stents in percutaneous coronary intervention (PCI) has significantly reduced rates of restenosis, compared with balloon angioplasty alone. On the contrary, small post-stenting luminal dimensions due to undilatable, heavily calcified plaques have repeatedly been shown to significantly increase the rates of in-stent restenosis. Rotational atherectomy of lesions is an alternative method to facilitate PCI and prevent underexpansion of stents, when balloon angioplasty fails to successfully dilate a lesion. Stentablation, using rotational atherectomy to expand underexpanded stents deployed in heavily calcified plaques, has also been reported. We report a case via the transradial approach of rotational-atherectomy–facilitated PCI of in-stent restenosis of a severely underexpanded stent due to a heavily calcified plaque. We review the literature and suggest rotational atherectomy may have a role in treating a refractory, severely underexpanded stent caused by a heavily calcified plaque through various proposed mechanisms. PMID:24436587

  17. Trial of self-expandable metallic stents in the palliation of tracheo ...

    African Journals Online (AJOL)

    Trial of self-expandable metallic stents in the palliation of tracheo-oesophageal fistula in carcinoma of the oesophagus. ... Over half of the patients in the TOF group had concomitant pneumonia at presentation with decreased survival (p = 0.010) and a hazard ratio of 10.86. Two patients died, on days 4 and 7 respectively.

  18. Clinical application of endovascular stent-graft in the treatment of portal stenosis of cancerous thrombus

    International Nuclear Information System (INIS)

    Jiang Zaibo; Huang Mingsheng; Wang Jing; Li Zhengran; Qian Jiesheng; Guang Shouhai; Zhu Kangshun; Shan Hong; Zhang Xiongjun

    2007-01-01

    Objective: To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Methods: Six cases with portal vein stenosis of cancerous thrombus, which caused by primary hepatic carcinoma (5 cases) and cholangiocarcinoma (1 case) and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded, were performed percutaneous transhepatic or transsplenic portography. FLUENCY TM endovascular stent-graft (10 mm diameter) was placed at the position of stenosis after gastroesophageal varices embolization. Portal pressure was measured pre- and post-deployment. Results: Stents were successfully placed in all patients. The average portal pressure decreased from 50.7 em H 2 O (1 cm H 2 O0.098 kPa) to 41.3 cm H 2 O after endovascular stent-graft deployment. The restenosis were found in 2 cases after one month. Haematemesis and refractory ascites appeared in one case respectively, the other 4 cases showed no significant symptoms above caused by portal hypertension. Conclusion: It is safe and feasible for endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Selecting the suitable indications, the symptoms of portal hypertension can be controlled effectively. (authors)

  19. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  20. Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Benjamin Bondue

    2016-01-01

    Full Text Available Endoscopic treatment of a bronchial restenosis previously treated by insertion of a partially covered self-expandable metallic stent (SEMS can be difficult. Classically, after recanalization of the bronchus, the stent is removed and replaced by a more adapted one. We report on two cases of proximal bronchial restenosis treated by insertion of an additional stent inside the lumen of the previously inserted stent using the stent-in-stent (SIS technique. The indications for the initial stent were malignancy in Patient 1 and posttransplant bronchial stenosis in Patient 2. Restenosis occurred at the proximal end of the stent within months in both cases. Stent removal and insertion of a new stent were considered, but this option was discarded because of an excessive risk of bronchial perforation and preference towards an alternative approach. In both cases, a second customized SEMS was placed using the SIS technique after ablation of the proximal end stenosis of the stent by argon plasma coagulation and/or dilation with a balloon. Recanalization of the bronchus was achieved in both cases without complications. The SIS technique is a valuable alternative to removal of SEMS in case of proximal bronchial restenosis.

  1. Analysis of emboli during carotid stenting with distal protection device.

    Science.gov (United States)

    Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V

    2006-01-01

    The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p protection device, 7,395 emboli with 42% solids were detected (p protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.

  2. Self-expandable metal stent placement versus emergency resection for malignant proximal colon obstructions

    NARCIS (Netherlands)

    Amelung, F.J.; Draaisma, W.A.; Consten, E.C.; Siersema, P.D.; Borg, F. ter

    2017-01-01

    BACKGROUND: Traditionally, all patients with a malignant obstruction of the proximal colon (MOPC) are treated with emergency resection. However, recent data suggest that Self-expandable metallic stent (SEMS) placement could lower mortality and morbidity rates. This study therefore aimed to compare

  3. Biodegradable stents in benign stenosis of the esophagus

    International Nuclear Information System (INIS)

    Manova, G.

    2013-01-01

    Full text: Introduction: Benign stenosis of the esophagus can be postcorrosion peptic or postoperative. The treatment is difficult and traditionally consists of multiple dilatations. In refractory stenosis the placement of metal self-expanding stents is disputed because requiring their subsequent removal. New experience for therapeutic decision is self- degradable stents. Manipulation is a single and not requires their removal. What you will learn: Patients indicated for the treatment with self- degradable stents are with benign stenosis not suitable for balloon dilatation or bougienage dilation. The main groups are those with postcorrosion stenosis, peptic stenosis due to untreated gastroesophageal reflux disease with different prescription as well as post-surgical and post-radiation stenosis. Self-expanding stents made by monofilament polymer of polydioxanone, whose integrity and radial force remain 6-8 weeks depending on the gastric pH are used. Stents are applied in hard guide placed in the stenosis through the working channel of gastroscopy, and they are released under X-ray control. Putting is preceded by balloon dilatation due to the large diameter of the mounted stent. During the manipulations, several difficulties are encountered, which are missing in self-expanding metal stents. Discussion: Short-term results are satisfactory - Dysphagia in the patients is overcome and they recover their normal diet. The patients reported no pain. The control inspection of the 1st month showed partial degradation of the stents. On 3rd month it is set the complete degradation. Term follow-up shows resumption of dysphagia. Conclusion: Good short-term results make the use of self-degradable stents possible alternative for the treatment of the esophagus refractory stenosis. Long-term results are contradictory, still missing long enough randomized studies on this topic

  4. Measurement of in vitro and in vivo stent geometry and deformation by means of 3D imaging and stereo-photogrammetry.

    Science.gov (United States)

    Zwierzak, Iwona; Cosentino, Daria; Narracott, Andrew J; Bonhoeffer, Philipp; Diaz, Vanessa; Fenner, John W; Schievano, Silvia

    2014-12-01

    To quantify variability of in vitro and in vivo measurement of 3D device geometry using 3D and biplanar imaging. Comparison of stent reconstruction is reported for in vitro coronary stent deployment (using micro-CT and optical stereo-photogrammetry) and in vivo pulmonary valve stent deformation (using 4DCT and biplanar fluoroscopy). Coronary stent strut length and inter-strut angle were compared in the fully deployed configuration. Local (inter-strut angle) and global (dog-boning ratio) measures of stent deformation were reported during stent deployment. Pulmonary valve stent geometry was assessed throughout the cardiac cycle by reconstruction of stent geometry and measurement of stent diameter. Good agreement was obtained between methods for assessment of coronary stent geometry with maximum disagreement of +/- 0.03 mm (length) and +/- 3 degrees (angle). The stent underwent large, non-uniform, local deformations during balloon inflation, which did not always correlate with changes in stent diameter. Three-dimensional reconstruction of the pulmonary valve stent was feasible for all frames of the fluoroscopy and for 4DCT images, with good correlation between the diameters calculated from the two methods. The largest compression of the stent during the cardiac cycle was 6.98% measured from fluoroscopy and 7.92% from 4DCT, both in the most distal ring. Quantitative assessment of stent geometry reconstructed from biplanar imaging methods in vitro and in vivo has shown good agreement with geometry reconstructed from 3D techniques. As a result of their short image acquisition time, biplanar methods may have significant advantages in the measurement of dynamic 3D stent deformation.

  5. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    International Nuclear Information System (INIS)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho; Ko, Ji Ho; Jeong, Kyung Soon

    2007-01-01

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

  6. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of University, Masan (Korea, Republic of); Jeong, Kyung Soon [University of Ulsan Colleg of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-09-15

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer.

  7. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  8. Self-Expandable Metal Stent for Closure of a Large Leak after Total Gastrectomy

    Directory of Open Access Journals (Sweden)

    G. Curcio

    2010-08-01

    Full Text Available In recent years, self-expandable metallic stents (SEMSs have emerged as a promising treatment alternative for the bridging and sealing of esophageal perforations and extensive anastomotic leaks after esophageal resection or total gastrectomy. A 56-year-old woman underwent a total gastrectomy with Roux-en-Y end-to-side esophagojejunostomy for a gastric signet ring cell carcinoma. Ten days later, esophagogastroduodenoscopy showed a 2 cm fistula in the distal end of the Roux limb of the anastomosis. This was confirmed by gastrografin esophagography. The patient was started on total parenteral nutrition. Having deemed clipping treatment for this fistula unfeasible, we decided to insert a partially silicone-coated SEMS (Evolution Controlled Release Esophageal Stent System, Cook Medical, Winston-Salem, N.C., USA. The stent was removed after ten days. Gastrografin esophagography showed no further contrast extravasation, and esophagogastroduodenoscopy showed closure of the fistula. No clinical complications were observed, and the patient was able to start normal per os nutrition. In conclusion, the treatment of symptomatic leaks in patients who have undergone esophagojejunostomy is challenging, and leakage from the jejunal stump can be a potentially serious complication. In the treatment of leakage after total gastrectomy, plastic stents (which are either too light or exercise too little radial force and totally covered metallic stents may not adhere sufficiently to the esophagojeujunal walls and, as a result, migrate beyond the anastomosis. The promising results of this report suggest that early stenting, using a partially silicone-coated SEMS, is a feasible alternative to surgical treatment in this category of patients.

  9. Percutaneous transhepatic self-expanding metal stents for palliation ...

    African Journals Online (AJOL)

    Stent occlusion occurred in 4 patients (8%) within a week as result of stent migration (n=3) or presumed biliary sludge (n=1); 2 (4%) stents occluded between 7 days and 1 month. Four patients (8%) died during hospital admission due to pre-existing biliary sepsis (n=3) and pneumonia (n=1). Nine patients developed ...

  10. Outcomes of endoscopically inserted self-expandable metal stents in malignancy according to the type of stent and the site of obstruction.

    Science.gov (United States)

    Jung, Kyoungwon; Ahn, Ji Yong; Jung, Hwoon-Yong; Cho, Charles J; Na, Hee Kyong; Jung, Kee Wook; Lee, Jeong Hoon; Kim, Do Hoon; Choi, Kee Don; Song, Ho June; Lee, Gin Hyug; Kim, Jin-Ho

    2016-09-01

    Self-expandable metal stents (SEMSs) can be used for the palliation of malignant obstruction in the upper gastrointestinal tract. This study assessed the feasibility and efficacy of endoscopically inserted SEMSs for the palliation of malignant obstruction in the stomach and duodenum. Between January 2011 and April 2014, 220 patients with gastric or duodenal obstruction due to malignancy underwent endoscopic SEMS insertion at Asan Medical Center. The associations of technical/clinical outcomes and complications with the type of stent and site of obstruction were analyzed. The 220 patients included 125 men (56.8 %) and 95 women (43.2 %); median patient age was 63 years. Fully covered, partially covered, and uncovered SEMSs were inserted into 16, 77, and 120 patients, respectively. Obstructions were located in the gastric outlet, including the duodenal bulb, in 106 patients, and in the duodenal second and third portions in 114 patients. Technical success was achieved in 213 of 220 patients (96.8 %) and clinical success in 184 of 213 (86.4 %). Clinical success rates were similar to the type of stent, but were significantly greater for gastric outlet (95/104, 91.3 %) than for duodenal (89/109, 81.7 %) obstructions (p = 0.039). Stent migration was observed in 20 patients (9.1 %) and stent obstruction in 51 (23.2 %). Rates of stent migration were significantly higher for fully covered (6/16, 37.5 %) than for partially covered (7/77, 9.1 %) and uncovered (7/120, 5.8 %) SEMSs (p stent obstruction were similar for fully covered (2/16, 12.5 %), partially covered (17/77, 22.1 %), and uncovered (32/120, 26.7 %) SEMSs (p = 0.409) and in patients with gastric outlet (26/104, 25.0 %) and duodenal (25/109, 22.9 %) obstruction (p = 0.724). SEMS selection for malignant obstruction of the upper gastrointestinal tract depends on the site of obstruction.

  11. Effects of the temporary placement of a self-expandable metallic stent in benign pyloric stenosis.

    Science.gov (United States)

    Choi, Won Jae; Park, Jong-Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2013-07-01

    The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Twenty-two patients with benign stenosis of the prepylorus, pylorus, and duodenal bulb were enrolled and underwent SEMS placement. We assessed symptom improvement, defined as an increase of at least 1 degree in the gastric-outlet-obstruction scoring system after stent insertion. No major complications were observed during the procedures. After stent placement, early symptom improvement was achieved in 18 of 22 patients (81.8%). During the follow-up period (mean 10.2 months), the stents remained in place successfully for 6 to 8 weeks in seven patients (31.8%). Among the 15 patients (62.5%) with stent migration, seven (46.6%) showed continued symptomatic improvement without recurrence of obstructive symptoms. Despite the symptomatic improvement, temporary SEMS placement is premature as an effective therapeutic tool for benign pyloric stenosis unless a novel stent is developed to prevent migration.

  12. Enterprise stent for the treatment of symptomatic intracranial atherosclerotic stenosis: an initial experience of 44 patients.

    Science.gov (United States)

    Feng, Zhengzhe; Duan, Guoli; Zhang, Ping; Chen, Lei; Xu, Yi; Hong, Bo; Zhao, Wenyuan; Liu, Jianmin; Huang, Qinghai

    2015-10-08

    Wingspan stenting for the treatment of complex intracranial atherosclerotic stenosis (ICAS), i.e., that involving tortuous vascular pathways, long (>15 mm) lesions or arterial bifurcations, has a relatively high risk of complications. This retrospective study assessed the safety and efficacy of undersized balloon angioplasty followed by deployment of the more flexible Enterprise stent for the treatment of complex symptomatic ICAS. Forty-four patients on combined antiplatelet therapy and intensive risk factor management and a symptomatic 70-99% stenosis of a major intracranial artery in complex settings that was treated with balloon angioplasty and Enterprise stent deployment between July 2009 and August 2013 were enrolled. Primary outcome was occurrence of ischemic or hemorrhagic stroke or death within 30 days after intervention. Secondary outcomes included procedural success (defined as achievement of 50% in-stent restenosis after mean 22 months follow-up. In this retrospective, single-center experience, undersized balloon angioplasty followed by Enterprise stent deployment appears technically feasible with a relatively low rate of complications for the treatment of complex symptomatic ICAS. Prospective, multicenter, randomized controlled trials against optimal medical management are warranted.

  13. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  14. Covered versus Uncovered Self-Expandable Metal Stents for Managing Malignant Distal Biliary Obstruction: A Meta-Analysis.

    Science.gov (United States)

    Li, Jinjin; Li, Tong; Sun, Ping; Yu, Qihong; Wang, Kun; Chang, Weilong; Song, Zifang; Zheng, Qichang

    2016-01-01

    To compare the efficacy of using covered self-expandable metal stents (CSEMSs) and uncovered self-expandable metal stents (UCSEMSs) to treat objective jaundice caused by an unresectable malignant tumor. We performed a comprehensive electronic search from 1980 to May 2015. All randomized controlled trials comparing the use of CSEMSs and UCSEMSs to treat malignant distal biliary obstruction were included. The analysis included 1417 patients enrolled in 14 trials. We did not detect significant differences between the UCSEMS group and the CSEMS group in terms of cumulative stent patency (hazard ratio (HR) 0.93, 95% confidence interval (CI) 0.19-4.53; p = 0.93, I2 = 0%), patient survival (HR 0.77, 95% CI 0.05-10.87; p = 0.85, I2 = 0%), overall stent dysfunction (relative ratio (RR) 0.85, M-H, random, 95% CI 0.57-1.25; p = 0.83, I2 = 63%), the overall complication rate (RR 1.26, M-H, fixed, 95% CI 0.94-1.68; p = 0.12, I2 = 0%) or the change in serum bilirubin (weighted mean difference (WMD) -0.13, IV fixed, 95% CI 0.56-0.3; p = 0.55, I2 = 0%). However, we did detect a significant difference in the main causes of stent dysfunction between the two groups. In particular, the CSEMS group exhibited a lower rate of tumor ingrowth (RR 0.25, M-H, random, 95% CI 0.12-0.52; p = 0.002, I2 = 40%) but a higher rate of tumor overgrowth (RR 1.76, M-H, fixed, 95% CI 1.03-3.02; p = 0.04, I2 = 0%). Patients with CSEMSs also exhibited a higher migration rate (RR 9.33, M-H, fixed, 95% CI 2.54-34.24; p = 0.008, I2 = 0%) and a higher rate of sludge formation (RR 2.47, M-H, fixed, 95% CI 1.36-4.50; p = 0.003, I2 = 0%). Our meta-analysis indicates that there is no significant difference in primary stent patency and stent dysfunction between CSEMSs and UCSEMSs during the period from primary stent insertion to primary stent dysfunction or patient death. However, when taking further management for occluded stents into consideration, CSEMSs is a better choice for patients with malignant biliary

  15. Treatment of Postoperative Leaks of the Upper Gastrointestinal Tract with Colonic Self-Expandable Metal Stents.

    Science.gov (United States)

    Sousa, Paula; Castanheira, António; Martins, Diana; Pinho, Juliana; Araújo, Ricardo; Cancela, Eugénia; Ministro, Paula; Silva, Américo

    2017-07-01

    The use of self-expandable metal stents (SEMS) for the treatment of postoperative leaks of the upper gastrointestinal tract is already established. However, there are discrepancies between the relatively small caliber of the esophageal stents available and the postsurgical luminal size, which may determine an inadequate juxtaposition. As colonic stents have a bigger diameter, they might be more adequate. Additionally, stents with a larger diameter might have a lower risk of migration. The aim of this study was to evaluate the efficacy and complications associated with the use of colonic fully covered SEMS (FSEMS) in the treatment of postoperative leaks in critical patients. All patients with postoperative leaks of the upper gastrointestinal tract treated with colonic stents (Hanarostent® CCI) between 2010 and 2013 were retrospectively included. Four patients with postoperative leaks were treated with colonic SEMS. The underlying surgeries were a gastric bypass, an esophagogastrectomy for Boerhaave syndrome, a primary repair of esophagopleural fistula due to Boerhaave syndrome, and an esophagectomy due to esophageal cancer. The leaks were detected on average 17 days after the initial surgery. All patients needed admission to a critical care unit after index surgery. Stent placement was technically feasible in all patients. The median residence time of the stents was 7 weeks, and no complications were verified when they were removed. There were no cases of stent migration. The treatment was successful in all patients, with complete healing of the leaks. The placement of colonic FSEMS seems to be successful and safe in the treatment of postoperative leaks of the upper gastrointestinal tract.

  16. Composite self-expanding bioresorbable prototype stents with reinforced compression performance for congenital heart disease application: Computational and experimental investigation.

    Science.gov (United States)

    Zhao, Fan; Xue, Wen; Wang, Fujun; Liu, Laijun; Shi, Haoqin; Wang, Lu

    2018-08-01

    Stents are vital devices to treat vascular stenosis in pediatric patients with congenital heart disease. Bioresorbable stents (BRSs) have been applied to reduce challenging complications caused by permanent metal stents. However, it remains almost a total lack of BRSs with satisfactory compression performance specifically for children with congenital heart disease, leading to importantly suboptimal effects. In this work, composite bioresorbable prototype stents with superior compression resistance were designed by braiding and annealing technology, incorporating poly (p-dioxanone) (PPDO) monofilaments and polycaprolactone (PCL) multifilament. Stent prototype compression properties were investigated. The results revealed that novel composite prototype stents showed superior compression force compared to the control ones, as well as recovery ability. Furthermore, deformation mechanisms were analyzed by computational simulation, which revealed bonded interlacing points among yarns play an important role. This research presents important clinical implications in bioresorbable stent manufacture and provides further study with an innovative stent design. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Malignant pyloro-duodenal obstruction: Role of self expandable metallic stents

    International Nuclear Information System (INIS)

    Qureshi, S.; Ghazanfar, S.; Quraishy, M.S.

    2014-01-01

    Objective: To determine the outcome of duodenal stenting in palliation of patients with malignant pyloric and duodenal obstruction. Methods: The non-randomised prospective descriptive study was conducted at the Endoscopy Suite, Surgical Unit-IV, Civil Hospital, Karachi, from December 2007 to November 2010. All patients presenting with inoperable ampullary, pancreatic or biliary cancers causing duodenal obstruction and patients with resectable malignancy but unfit for surgery were included. The procedure was carried out by a single expert endoscopist under local or general anaesthaesia as required. Boston Scientific stents of variable sizes were used. Follow-up was done at 1 week, 1 month and 6 months. Data analysis was done using SPSS 15. Results: Over the study period, 159 (60%) males and 6 (40%) females were included in the study. The male-to-female ratio was 2:3. The overall age ranged from 25-80 years with a mean of 52.67+-15.07 years. Primary diagnosis was pyloric carcinoma in 7(46.6%), carcinoma Gallbladder in 4(26.6%), Duodenal carcinoma in 3(20%) and carcinoma head of pancreas in 1(6.6%). Relief of symptoms were seen in 11 (73.3%), while complications were seen in 2 (13.3%). Stents were inserted with technical success in 14 (93%) patients. Clinical success was seen in 11 (73%), with a mean survival of 74.27+-40.7 days (range: 15-180 days). No statistical significance was found when comparing the survival time with age, gender and diagnosis. Conclusion: Use of self-expandable metallic stents for gastroduodenal malignancies appears to be a feasible, safe and effective method, especially in those patients with limited life expectancy. (author)

  18. Endoscopic ultrasound-guided biliary drainage using a newly designed metal stent with a thin delivery system: a preclinical study in phantom and porcine models.

    Science.gov (United States)

    Minaga, Kosuke; Kitano, Masayuki; Itonaga, Masahiro; Imai, Hajime; Miyata, Takeshi; Yamao, Kentaro; Tamura, Takashi; Nuta, Junya; Warigaya, Kenji; Kudo, Masatoshi

    2017-12-08

    This study was designed to evaluate the feasibility and safety of a newly designed self-expandable metal stent for endoscopic ultrasound-guided biliary drainage (EUS-BD) when it was delivered via three different stent delivery systems: a 7.5Fr delivery catheter with a bullet-shaped tip (7.5Fr-bullet), a 7Fr catheter with a bullet-shaped tip (7Fr-bullet), or a 7Fr catheter with a tee-shaped tip (7Fr-tee). This experimental study utilized a porcine model of biliary dilatation involving ten pigs. In the animal study, technical feasibility and clinical outcomes of the stent when placed with each of the delivery systems were examined. In addition, a phantom model was used to measure the resistance of these delivery systems to advancement. Phantom experiments showed that, compared with 7Fr-bullet, 7Fr-tee had less resistance force to the advancement of the stent delivery system. EUS-BD was technically successful in all ten pigs. Fistulous tract dilation was necessary in 100% (2/2), 75% (3/4), and 0% (0/4) of the pigs that underwent EUS-BD using 7.5Fr-bullet, 7Fr-bullet, and 7Fr-tee, respectively. There were no procedure-related complications. Our newly designed metal stent may be feasible and safe for EUS-BD, particularly when delivered by 7Fr-tee, because it eliminates the need for fistulous tract dilation.

  19. Deployment technique that takes advantage of the characteristics of Enterprise VRD2: an in vitro study.

    Science.gov (United States)

    Chihara, Hideo; Ishii, Akira; Kikuchi, Takayuki; Ikeda, Hiroyuki; Arai, Daisuke; Miyamoto, Susumu

    2017-10-01

    Enterprise VRD, a stent frequently used to assist coil embolization of cerebral aneurysms, has been upgraded to reduce the risk of incomplete stent apposition (ISA), a known risk factor for thromboembolic complications. To compare the performances of Enterprise VRD and Enterprise VRD2 in curved vessels, and to investigate a deployment method that takes advantage of the features of Enterprise VRD2 to achieve better vessel wall apposition. A silicone vascular model connected to a temperature-adjustable perfusion circuit was used. First, Enterprise VRD and Enterprise VRD2 were deployed under fluoroscopy and then ISA was evaluated as the stent cross-sectional area ratio at the curved segment of the vessel. For the measurements, each stent was deployed in vessels with different angles of curvature. Second, the incidence of ISA after insertion of Enterprise VRD2 by the 'pushing over outer curve technique', in which stents are deployed along the outer curve of vessels with continuous wire advancement, was compared with 'Heller's push and pull technique'. For all stents, the cross-sectional area ratio decreased with acute curvature of the vessel. Comparisons of the two stents showed that Enterprise VRD2 was better than Enterprise VRD in maintaining a greater cross-sectional area ratio in curved vessels. In addition, kinking with an acute curvature was also minimized with Enterprise VRD2. Furthermore, ISA was reduced using our technique with Enterprise VRD2. Enterprise VRD2 is superior to Enterprise VRD in reducing ISA in curved vessels and can alter ISA according to the deployment technique used. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Safety and efficacy of a fully covered large-diameter self-expanding metal stent for the treatment of upper gastrointestinal perforations, anastomotic leaks, and fistula

    NARCIS (Netherlands)

    van den Berg, M. W.; Kerbert, A. C.; van Soest, E. J.; Schwartz, M. P.; Bakker, C. M.; Gilissen, L. P. L.; van Hooft, J. E.

    2016-01-01

    Upper gastrointestinal perforations, fistula, and anastomotic leaks are severe conditions with high mortality. Temporary endoscopic placement of fully covered self-expanding metal stent (fSEMS) has emerged as treatment option. Stent migration is a major drawback of currently used stents. Migration

  1. In vivo evaluation of axial integrity of coronary stents using intravascular ultrasound: Insights on longitudinal stent deformation.

    Science.gov (United States)

    Dvir, Danny; Kitabata, Hironori; Barbash, Israel M; Minha, Sa'ar; Badr, Salem; Loh, Joshua P; Chen, Fang; Torguson, Rebecca; Waksman, Ron

    2014-09-01

    To evaluate the axial integrity of different coronary stents using intravascular ultrasound (IVUS). Longitudinal stent deformation was recently reported. Consecutive patients who underwent IVUS analysis after drug-eluting stent (DES) implantation for de novo coronary lesions were evaluated. Stent length was compared with label length for calculation of absolute change and relative difference (absolute change divided by label length). A total of 233 DES utilizing five different platforms were included. The median absolute change in stent length was 0.90 mm (interquartile range [IQR] 0.48-1.39) and the relative difference was 5.24% (IQR 2.55-8.29). There was no significant difference among the groups in median absolute or relative change: Cypher 0.89 mm/3.89%, Taxus 0.88 mm/5.39%, Endeavor 1.16 mm/6.77%, Xience V 0.86 mm/5.80%, and PROMUS Element 0.79 mm/5.34% (P = 0.085, P = 0.072, respectively). Multivariate logistic regression revealed that the Cypher stent was independently correlated with a lower change in length, whereas stent label length and deployment pressure were correlated with higher absolute change. The axial integrity of DES platforms examined in vivo was high, with only mild changes in stent length after implantation. While there are differences between first- and second-generation DES, axial integrity among second-generation DES was similar. © 2013 Wiley Periodicals, Inc.

  2. Enhanced endothelial cell functions on rosette nanotube-coated titanium vascular stents

    Directory of Open Access Journals (Sweden)

    Eli Fine

    2009-04-01

    Full Text Available Eli Fine1, Lijie Zhang1, Hicham Fenniri2, Thomas J Webster1 1Department of Engineering, Brown University, Providence, RI, USA; 2National Institute for Nanotechnology and Department of Chemistry, University of Alberta, Edmonton, AB, CanadaAbstract: One of the main problems with current vascular stents is a lack of endothelial cell interactions, which if sufficient, would create a uniform healthy endothelium masking the underlying foreign metal from inflammatory cell interference. Moreover, if endothelial cells from the arterial wall do not adhere to the stent, the stent can become loose and dislodge. Therefore, the objective of this in vitro study was to design a novel biomimetic nanostructured coating (that does not contain drugs on conventional vascular stent materials (specifically, titanium for improving vascular stent applications. Rosette nanotubes (RNTs are a new class of biomimetic nanotubes that self-assemble from DNA base analogs and have been shown in previous studies to sufficiently coat titanium and enhance osteoblast cell functions. RNTs have many desirable properties for use as vascular stent coatings including spontaneous self-assembly in body fluids, tailorable surface chemistry for specific implant applications, and nanoscale dimensions similar to those of the natural vascular extracellular matrix. Importantly, the results of this study provided the first evidence that RNTs functionalized with lysine (RNT–K, even at low concentrations, significantly increase endothelial cell density over uncoated titanium. Specifically, 0.01 mg/mL RNT–K coated titanium increased endothelial cell density by 37% and 52% compared to uncoated titanium after 4 h and three days, respectively. The excellent cytocompatibility properties of RNTs (as demonstrated here for the first time for endothelial cells suggest the need for the further exploration of these novel nanostructured materials for vascular stent applications.Keywords: stents

  3. Self-expandable medical memorial metallic stent with 125I seeds for the treatment of esophageal carcinoma: a retrospective analysis

    International Nuclear Information System (INIS)

    Zhang Shuo; Lu Bin

    2011-01-01

    Objective: To discuss the curative effect and safety of the implantation of self-expandable medical memorial metallic stent with 125 I seeds for the treatment of advanced esophageal carcinomas. Methods: Implantation of self-expandable medical memorial metallic stent with 125 I seeds was performed in 32 patients with advanced esophageal canner. The clinical data were retrospectively analyzed. The technical success rate, the operation time, the immediate and mid-term effectiveness, the survival time, the complications, the body weight, the blood picture, the immune indexes, the average hospitalization days and hospitalization expenses were analyzed. Results: The average operation time was (18±5) minutes. Successful stent implantation was achieved in all 32 patients (100%). No 125 I seeds fell off during the procedure. The remission rate of dysphagia was 100%. Esophageal restenosis occurred in four patients, and displacement of the stent was seed in one patient. One month after the treatment, 90% of patients had a Karnofsky performance score over 60. The mean survival time was (8.7±6.6) months. The average hospitalization time was (7.8±3.7) days and the mean hospitalization cost was (12±3) thousand Chinese Yuan. Conclusion: For the treatment of esophageal carcinomas, the implantation of self-expandable medical memorial metallic stent with 125 I seeds is safe, effective and simple. This treatment can markedly improve the symptom of dysphagia and significantly prolong the patient's survival time. (authors)

  4. Comparison of Recanalization and In-Stent Stenosis Between the Low-Profile Visualized Intraluminal Support Stent and Enterprise Stent-Assisted Coiling for 254 Intracranial Aneurysms.

    Science.gov (United States)

    Feng, Xin; Qian, Zenghui; Liu, Peng; Zhang, Baorui; Wang, Luyao; Guo, Erkang; Wen, Xiaolong; Xu, Wenjuan; Jiang, Chuhan; Wu, Zhongxue; Li, Youxiang; Liu, Aihua

    2018-01-01

    To compare the rates of recanalization and in-stent stenosis between the Enterprise (EP) and low-profile visualized intraluminal support (LVIS) stent deployments for intracranial aneurysms (IAs), and the factors associated therein. Between June 2014 and July 2016, 142 patients with a total of 161 IAs were treated by LVIS stent-assisted coiling and 111 patients with a total of 142 IAs were treated by EP stent-assisted coiling at our institution. Procedure-related complications, angiographic follow-up results, and clinical outcomes were analyzed statistically. The rates of initially complete and near-complete IA occlusion immediately after the procedure were similar in the LVIS and EP groups (94.3% vs. 89.9%; P = 0.275). On follow-up, complete and near-complete occlusion rates and recanalization rates were also similar in the 2 groups (96.6% vs. 92.1%; P =0.330 and 8.0% vs. 13.5%; P = 0.245, respectively). On logistic regression analysis, a higher size ratio (SR) was significantly associated with the recanalization of aneurysms in the EP group, but not in the LVIS group. The rate of moderate to severe in-stent stenosis was lower in the LVIS group (10.2%) than in the EP group (16.8%), but the difference was not statistically significant (P = 0.198). Our data show acceptable rates of complete and near-complete occlusion with both the LVIS and EP stents. LVIS stents were associated with lower rates of recanalization and in-stent stenosis, but the difference was not significant. Higher SR (≥2) was a significant predictor of recanalization in IAs treated with EP stents, but not in those treated with LVIS stents. Copyright © 2017. Published by Elsevier Inc.

  5. Utilization of self-expanding stents in the treatment of intracranial atherosclerotic disease in the distal small cerebral vessels

    International Nuclear Information System (INIS)

    Turk, Aquilla S.; Niemann, David B.; Aagaard-Kienitz, Beverly; Ahmed, Azam; Brooks, Nathaniel; Levine, Ross L.

    2007-01-01

    Previously, endovascular treatment of stenosis related to intracranial atherosclerosis (ICAD) involving arteries measuring less than 2 mm in diameter was limited. To our knowledge, there are no reports in the literature addressing stent placement for treatment of stenosis in arteries of this size. Four patients aged 33 to 80 years (mean 57.5 years) with medically refractory ICAD underwent angioplasty and stenting of small (<2 mm) distal intracerebral arteries. Vessel location and length of follow-up were anterior cerebral artery (ACA) A1 segment (5 months), ACA A2 segment (18 months), middle cerebral artery M1 segment (18 months), and posterior cerebral artery P1 segment (8 months) with vessel calibers ranging from 1.2 to 1.8 mm. Clinical and imaging follow-up ranged from 5 to 18 months. All procedures were successfully performed without complications. Follow-up out to 18 months demonstrated one vessel that went on to occlusion while the other stented vessel segments remained patent. One patient died 8 months after stenting, but the death was not related to neurological disease. The remaining patients experienced resolution of the presenting symptomatology and remained asymptomatic throughout follow-up. In this small series, stenoses of distal (<2 mm) cerebral arteries were amenable to treatment using new self-expanding stents. We safely and successfully treated four arteries smaller than 2 mm in diameter with newer self-expanding stents. All patients remained clinically asymptomatic. One stent occluded at 5 months and the others remained patent during follow-up. Longer term clinical follow-up is required to determine the durability and viability of this therapy. (orig.)

  6. Self-deployable mobile sensor networks for on-demand surveillance

    Science.gov (United States)

    Miao, Lidan; Qi, Hairong; Wang, Feiyi

    2005-05-01

    This paper studies two interconnected problems in mobile sensor network deployment, the optimal placement of heterogeneous mobile sensor platforms for cost-efficient and reliable coverage purposes, and the self-organizable deployment. We first develop an optimal placement algorithm based on a "mosaicked technology" such that different types of mobile sensors form a mosaicked pattern uniquely determined by the popularity of different types of sensor nodes. The initial state is assumed to be random. In order to converge to the optimal state, we investigate the swarm intelligence (SI)-based sensor movement strategy, through which the randomly deployed sensors can self-organize themselves to reach the optimal placement state. The proposed algorithm is compared with the random movement and the centralized method using performance metrics such as network coverage, convergence time, and energy consumption. Simulation results are presented to demonstrate the effectiveness of the mosaic placement and the SI-based movement.

  7. Physical properties of a new type of self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Soo [Seoul Health College, Seoul (Korea, Republic of); Kim, Tae Hyung; Song, Sang Woo; Kang, Seong Gwon; Huh, Soo Jin; Song, Ho Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of); Kim, Eun Sang [Stentech, Inc., Seoul (Korea, Republic of); Kim, Cheol Saeng [Solco Surgical Instruments Co., Ltd, Seoul (Korea, Republic of)

    1999-08-01

    To study the new physical properties including hoop strength and flexibility of a newly developed nitinol stent. The new stent was made of a single nitinol wire 0.15 - 0.25 mm in diameter. This was wound around a cylindrical metallic jig with a constant angle to the longitudinal direction, and stents which winding were constructed. Hoop strength of the stents was measured with a spring gauge and compared with that of Wallstent and Hanaro stents. The flexibility of the new stent was evaluated on the basis of changes in stent diameter when bent in the direction of 180 deg Hoop strength of the new nitinol stent was proportional to 3.8 ({+-}0.3)-th power of the wire thickness. A greater number of wires on a lateral cut surface or a greater number of longitudinal windings also resulted in increased strength. However, the former caused an increase in total wire area and the latter resulted increased stent length when compressed. Hoop strength of the new nitinol stent was superior to that of Wallstent and Hanaro stents, and stent diameter did not decrease when the stent was bent in the direction of 180 degrees. Hoop strength of the new nitinol stent was most significantly affected by wire thickness. The stent was very flexible and thus seemed suitable for an angled lumen.

  8. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature.

    Science.gov (United States)

    van Halsema, Emo E; Rauws, Erik A J; Fockens, Paul; van Hooft, Jeanin E

    2015-11-21

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that reported on the clinical success of stent placement for MGOO were included. The primary endpoint was clinical success, defined according to the definition used in the original article. Data were pooled and analyzed using descriptive statistics. Subgroup analyses were performed for partially covered SEMSs (PCSEMSs) and uncovered SEMSs (UCSEMSs) using Fisher's exact test. A total of 19 studies, including 1281 patients, were included in the final analysis. Gastric (42%) and pancreatic (37%) cancer were the main causes of MGOO. UCSEMSs were used in 76% of patients and PCSEMSs in 24%. The overall pooled technical success rate was 97.3% and the clinical success rate was 85.7%. Stent dysfunction occurred in 19.6% of patients, mainly caused by re-obstruction (12.6%) and stent migration (4.3%), and was comparable between PCSEMSs and UCSEMSs (21.2% vs 19.1%, respectively, P = 0.412). Re-obstruction was more common with UCSEMSs (14.9% vs 5.1%, P stent migration was more frequent after PCSEMS placement (10.9% vs 2.2%, P stent patency ranged from 68 to 307 d in five studies. The median overall survival ranged from 49 to 183 d in 13 studies. The clinical outcomes in this large population showed that enteral stent placement was feasible, effective and safe. Therefore, stent placement is a valid treatment option for the palliation of MGOO.

  9. Transjugular Intrahepatic Portosystemic Shunt Flow Reduction with Adjustable Polytetrafluoroethylene-Covered Balloon-Expandable Stents Using the “Sheath Control” Technique

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward; Patel, Rahul S.; Scott Nowakowski, F.; Lookstein, Robert A.; Fischman, Aaron M. [Icahn School of Medicine at Mount Sinai, Interventional Radiology Section, Department of Radiology (United States)

    2016-06-15

    PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloon retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.

  10. [Evaluation of stents in treating childhood benign esophageal strictures].

    Science.gov (United States)

    Reinshagen, K; Kähler, G; Manegold, B C; Waag, K-L

    2009-01-01

    Esophageal stenting is a popular of treatment of esophageal strictures in adults. It has also been described for children with benign strictures who did not respond to standard dilatation therapy. The aim of the study was to evaluate weather esophageal stents could be used safely and effectively in the treatment of benign esophageal strictures in children. From 1993 to 2005 stenting therapy was performed in 12 children with complicated esophageal strictures. Etiologies of the strictures were caustic burns in 9 patients, postoperative strictures due to complicated esophageal atresia in 2 patients and iatrogenic esophageal injury in 1 patient. Esophageal silicon tubi, covered retrievable expandable nitinol and plastic stents were placed endoscopically. The clinical course and the long term follow up were evaluated retrospectively The stents and tubi were placed in all patients without complications and were later removed successfully. 6 patients were treated with a self expanding plastic stent. The plastic stents showed a distinct tendency to migrate but in 5/6 patients esophageal stricture was treated successfully. 3 patients were treated by a covered self expanding nitinol stent. No migration occurred. One patient was asymptomatic after therapy, one required further dilatation therapy and the third had esophageal resection. 3 patients were treated by esophageal tubi. 2 patients required surgery in the follow up, one patient is asymptomatic. The use of stenting devices in children to treat benign esophageal strictures is safe and efficient. The self expanding plastic stents had the best long term results but required high compliance of parents and children due to the tendency of stent migration. Self expanding nitinol stents are more traumatic at the extraction procedure and are useful in patients with low compliance. Recurrence of strictures occurred most often after esophageal tubi possibly due to the lack of radial expansion.

  11. Palliative metallic stent placement for managing esophageal cancer of the aging

    International Nuclear Information System (INIS)

    Li Qnqi; Yin Huabin; Yue Wei; Ji Chengzhou; Yang Yufeng

    2000-01-01

    Objective: To evaluate the effectiveness of self-expanding metallic stent in the treatment of the old patients with malignant esophageal stricture. Methods: 32 old patients with malignant esophageal stricture were treated with covered self-expandable metallic stents, 32 stents were placed by X-TV guiding, without pre-dilatation of the stenosis by balloon catheter. Results: All 32 stents were successfully placed, the successful rate was 100%. All of the patients obtained the improvement of the food intake ability. No fatal stent-related complications occurred. The average survival time was 6.5 months. Conclusions: The covered self-expandable metallic stent is effective in the palliative management of malignant esophageal stricture of the aging

  12. Design and optimization of a self-developing single axis tracking PV array

    International Nuclear Information System (INIS)

    Colozza, A.J.

    1992-01-01

    This paper reports on a study performed in order to design a tracking PV array and optimize the design for maximum specific power. The design considerations were minimal deployment time, high reliability and small stowage volume. The array design was self-deployable, from a compact stowage configuration, using a passive pressurized gas deployment mechanism. The array structural components consist of a combination of beams, columns and cables used to deploy and orient a flexible PV blanket. Each structural component of the design was analyzed to determine the size necessary to withstand the various forces it would be subjected to. An optimization was performed to determine the array dimensions and blanket geometry which produce the maximum specific power

  13. Insertion of a self-expandable endotracheal metal stent using topical anaesthesia and a fibreoptic bronchoscope: a comfortable way to offer palliation.

    OpenAIRE

    Coolen, D.; Slabbynck, H.; Galdermans, D.; Van Schaardenburg, C.; Mortelmans, L. L.

    1994-01-01

    A self-expandable stent was used to obtain prolonged relief of stridor resulting from tracheal obstruction by extrinsic tumour compression despite prior external irradiation. The stent was inserted in an easy and comfortable procedure with fibreoptic bronchoscopy under local anaesthesia.

  14. Fully covered self-expanding metal stents are effective for benign esophagogastric disruptions and strictures.

    Science.gov (United States)

    Wilson, Jennifer L; Louie, Brian E; Farivar, Alexander S; Vallières, Eric; Aye, Ralph W

    2013-12-01

    Self-expanding fully covered metal stents (CSs) are ideal for use in benign esophagogastric disease. We reviewed our experience with CS to evaluate outcomes, to determine a role for CS in a standard treatment for benign esophageal conditions, and to compare our results with recently published studies. We performed a retrospective chart review from 2005 to 2012. A total of 57 CSs were placed in 44 patients. Indications were stricture (11 patients), anastomotic leak (20), perforation (7), and tracheoesophageal fistulae (6). For GI tract disruptions, open repair or diversion was avoided in 31/33 patients (93.9 %) but required an associated drainage procedure in 22/33 (67 %) patients. Resolution does not depend on achieving radiological control with 6/26 (23 %) having evidence of a persistent leak. Benign strictures were dilated at a mean of 3.7 times prior to stenting. Adjunctive intra-mucosal steroid injections were used in 8/11 patients. Stents were removed at a mean of 33 days. At a mean of 283 days of follow-up, 6/11 (54.5 %) had symptom resolution. The most common complication was stent migration occurring in 17.5 % of patients overall. Covered stents are an effective adjunct in the management of benign upper gastrointestinal tract fistulae, leaks, perforations and benign strictures.

  15. Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(L-lactide) In Vitro and In Vivo

    DEFF Research Database (Denmark)

    Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo

    2017-01-01

    implants each for 2 and 3½ weeks, respectively. Results  In vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all......  A bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures....

  16. Stent migration following endoscopic suture fixation of esophageal self-expandable metal stents: a systematic review and meta-analysis.

    Science.gov (United States)

    Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth

    2018-02-01

    Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2  = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2  = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.

  17. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  18. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution

    Science.gov (United States)

    Coté, Gregory A.; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K.; Elmunzer, B. Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D.; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart

    2017-01-01

    IMPORTANCE Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. OBJECTIVE To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. DESIGN, SETTING, AND PARTICIPANTS Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. INTERVENTIONS Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. MAIN OUTCOMES AND MEASURES Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of −15%. RESULTS There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, −3.0% to ∞; P stents was rejected. The mean number of ERCPs to achieve resolution

  19. Challenges to Deploy Service Design in Organizations

    DEFF Research Database (Denmark)

    Akasaka, Fumiya; Ohno, Takehiko; Jensen, Mika Yasuoka

    2016-01-01

    More and more companies are applying service design approaches to develop services and products. Not every project, however, has achieved its goals. In many cases, difficulties arise from organizational issues such as organization structure and evaluation system. In this research, we held workshops...... where success and failure factors of service design projects in organization are presented. By analysing the results, we construct a model that explains the “difficulties of deploying the service design approach in organization.” On the basis of the model, this paper discusses the challenges...... to the deployment of the service design approach in organizations....

  20. Radiologic placement of metallic esophageal stents: preliminary experience

    International Nuclear Information System (INIS)

    Good, S.; Asch, M.R.; Jaffer, N.; Casson, A.G.

    1997-01-01

    To assess the usefulness of covered, self expanding metallic stents for alleviating stricture associated with malignant esophageal lesions. Patients and methods: Self-expanding metallic stents were placed in 10 patients with dysphagia related to stricture caused by malignant esophageal lesions. The stents were placed fluoroscopically with local anesthesia, and patency of the esophageal lumen was assessed by barium study after the procedure. The patients were then followed clinically. Results: In all 10 cases patency of the lumen was renewed after stent placement. After the procedure 9 of the patients could tolerate a normal or near-normal diet; in the other patient esophageal perforation occurred, and clinical deterioration prevented oral intake of food. In one patient, 2 stents were needed because of the length of the stricture. Two patients experienced reflux after placement of the stent across the gastro-esophageal junction. Another patient had asymptomatic aspiration after stent placement in the proximal esophagus. In 2 patients, symptoms associated with tracheoesophageal fistula were relieved after placement of the stents. Six of the 10 patients died; mean survival after the procedure was 12 (range 1 to 56) weeks. The other 4 patients were alive at the time of writing, having survived for a mean of 7.5 (range 2 to 13) weeks; all of these patients tolerated a near-normal diet. Conclusions: The placement of covered, self-expanding metallic stents is a quick, effective method of palliating dysphagia related to stricture caused by malignant esophageal lesions. (author)

  1. COMMUNICATION: Toward a self-deploying shape memory polymer neuronal electrode

    Science.gov (United States)

    Sharp, Andrew A.; Panchawagh, Hrishikesh V.; Ortega, Alicia; Artale, Ryan; Richardson-Burns, Sarah; Finch, Dudley S.; Gall, Ken; Mahajan, Roop L.; Restrepo, Diego

    2006-12-01

    The widespread application of neuronal probes for chronic recording of brain activity and functional stimulation has been slow to develop partially due to long-term biocompatibility problems with existing metallic and ceramic probes and the tissue damage caused during probe insertion. Stiff probes are easily inserted into soft brain tissue but cause astrocytic scars that become insulating sheaths between electrodes and neurons. In this communication, we explore the feasibility of a new approach to the composition and implantation of chronic electrode arrays. We demonstrate that softer polymer-based probes can be inserted into the olfactory bulb of a mouse and that slow insertion of the probes reduces astrocytic scarring. We further present the development of a micromachined shape memory polymer probe, which provides a vehicle to self-deploy an electrode at suitably slow rates and which can provide sufficient force to penetrate the brain. The deployment rate and composition of shape memory polymer probes can be tailored by polymer chemistry and actuator design. We conclude that it is feasible to fabricate shape memory polymer-based electrodes that would slowly self-implant compliant conductors into the brain, and both decrease initial trauma resulting from implantation and enhance long-term biocompatibility for long-term neuronal measurement and stimulation.

  2. The study of metal stents for effect to the radiation therapy

    International Nuclear Information System (INIS)

    Gao Li; Feng Ningyuan; Zhai Renyou; Yang Weizhi; Xu Guozhen; Wang Yafei

    2001-01-01

    Objective: To confirm whether the metal stents affect the radiation beam. Methods: The transmission factors from the national self-expanding esophagus stent, stainless self-expanding bile duct stent, and balloon-expanded vascular stent was supervised under 192 Ir irradiation in the air. Results: The transmission factors from the 3 kinds of metal stents were 0.993, 0.988, and 0.997, which meant that the attenuation of the stents to the radiation was 0.7%, 1.2%, and 0.3%, respectively (mean: 0.7%). Conclusion: The effect of the metal stents to the radiation was less than 1.2% and that meant there was no clinical significant effect on the patients irradiated following stent implantation or to perform the intra-stents brachytherapy

  3. Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, Claus Christian, E-mail: Claus.christian.pieper@ukb.uni-bonn.de; Meyer, Carsten, E-mail: Carsten.Meyer@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany); Rudolph, Jens, E-mail: jens.rudolph@ukb.uni-bonn.de; Verrel, Frauke, E-mail: frauke.verrel@ukb.uni-bonn.de [University of Bonn, Department of Surgery (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de; Wilhelm, Kai E., E-mail: kai.wilhelm@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany)

    2013-08-01

    PurposeThis study was designed to evaluate retrospectively the results of complex iliac artery aneurysm (IAA) exclusion using the Cardiatis-Multilayer-Stent.MethodsBetween October 2010 and August 2012, ten IAAs were treated in eight males (mean age 75 (59-91) years) using the Multilayer Stent. All IAA exceeded a diameter of 3 cm or were symptomatic. Follow-up (FU) examinations included CT or MR angiography, sonography, and clinical assessment up to 2 years.ResultsPrimary stent placement was technically successful in eight of ten cases. In two cases, severe stent retraction during deployment necessitated placement of an additional stent. Immediately after stent placement, a marked reduction of flow within the sac was observed in all cases (peri-interventional mortality 0 %). During FU, there were two thrombotic stent occlusions, making reintervention necessary (primary patency rate 80 %, secondary patency 100 %). Four IAA were completely occluded at FU, whereas the original vessel and covered branches (n = 8) were patent. In four IAA, there was still residual perfusion. In one patient, IAA diameter decreased slightly, while it remained constant in seven (mean imaging FU 195 (range 1-695) days). There were no adverse events on clinical FU (mean FU 467 (range 101-695) days).ConclusionsOther studies showed the Cardiatis-Multilayer-Stent to be a technically relatively simple treatment option for complex IAA with inadequate landing zones, especially in patients with multiple comorbidities to avoid ipsilateral IIA obstruction. However, in our series complication rate was high. Incomplete sac exclusion, stent-shortening, and thrombotic occlusion can complicate treatment, making meticulous patient selection necessary. Close imaging surveillance is mandatory especially in the early postinterventional period.

  4. Particle imaging velocimetry evaluation of intracranial stents in sidewall aneurysm: hemodynamic transition related to the stent design.

    Science.gov (United States)

    Bouillot, Pierre; Brina, Olivier; Ouared, Rafik; Lovblad, Karl-Olof; Farhat, Mohamed; Pereira, Vitor Mendes

    2014-01-01

    We investigated the flow modifications induced by a large panel of commercial-off-the-shelf (COTS) intracranial stents in an idealized sidewall intracranial aneurysm (IA). Flow velocities in IA silicone model were assessed with and without stent implantation using particle imaging velocimetry (PIV). The use of the recently developed multi-time-lag method has allowed for uniform and precise measurements of both high and low velocities at IA neck and dome, respectively. Flow modification analysis of both regular (RSs) and flow diverter stents (FDSs) was subsequently correlated with relevant geometrical stent parameters. Flow reduction was found to be highly sensitive to stent porosity variations for regular stents RSs and moderately sensitive for FDSs. Consequently, two distinct IA flow change trends, with velocity reductions up to 50% and 90%, were identified for high-porosity RS and low-porosity FDS, respectively. The intermediate porosity (88%) regular braided stent provided the limit at which the transition in flow change trend occurred with a flow reduction of 84%. This transition occurred with decreasing stent porosity, as the driving force in IA neck changed from shear stress to differential pressure. Therefore, these results suggest that stents with intermediate porosities could possibly provide similar flow change patterns to FDS, favourable to curative thrombogenesis in IAs.

  5. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon; Seo, Tae-Seok; Yuk, Soon Hong; Kim, Young-Hwa; Cho, Yong-Mee

    2005-01-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean±standard deviation, 46.88±23.75) than in the CS (73.75±14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63±2.05) than in CS (3.49±2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  6. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, Seoul (Korea); Seo, Tae-Seok [Gachon Medical School, Department of Radiology, Gil Medical Center, Inchon (Korea); Yuk, Soon Hong [Hannam University, Department of Polymer Science and Engineering, College of Engineering, Daejeon (Korea); Kim, Young-Hwa [Soonchunhyang University Chonan Hospital, Department of Radiology, Chonan (Korea); Cho, Yong-Mee [University of Ulsan College of Medicine, Department of Pathology, Asan Medical Center, Seoul (Korea)

    2005-06-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean{+-}standard deviation, 46.88{+-}23.75) than in the CS (73.75{+-}14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63{+-}2.05) than in CS (3.49{+-}2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  7. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    Science.gov (United States)

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. High-Performance Elastically Self-Deployed Roll-Out Solar Array (ROSA), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Deployable Space Systems (DSS) has developed an ultra-lightweight elastically self-deployable roll-out solar array (ROSA) structural platform that when combined with...

  9. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  10. Indications for stenting during thrombolysis

    DEFF Research Database (Denmark)

    Bækgaard, N; Broholm, R; Just, Sven Richardt Lundgren

    2013-01-01

    of a stent in this position is the treatment of choice facilitating the venous flow into an unobstructed outflow tract either from the femoral vein or the deep femoral vein or both. The stent, made of stainless steel or nitinol, has to be self-expandable and flexible with radial force to overcome...... the challenges in this low-pressure system. The characteristics of the anatomy with external compression and often a curved vein segment with diameter difference make stent placement necessary. Ballooning alone has no place in this area. The proportion of inserted stents varies in the published materials...

  11. Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent

    International Nuclear Information System (INIS)

    Rabellino, Martin; García-Nielsen, Luis; Zander, Tobias; Baldi, Sebastián; Llorens, Rafael; Maynar, Manuel

    2011-01-01

    Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as a mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.

  12. Incidence and mechanisms of longitudinal stent deformation associated with Biomatrix, Resolute, Element, and Xience stents: Angiographic and case-by-case review of 1,800 PCIs.

    Science.gov (United States)

    Arnous, Samer; Shakhshir, Nizar; Wiper, Andrew; Ordoubadi, Farzin-Farth; Williams, Paul; Clarke, Bernard; Mahadavan, Vaikom; El-Omar, Magdi; Mamas, Mamas; Fraser, Douglas

    2015-11-15

    There is conflicting evidence regarding the incidence of longitudinal stent deformation (LSD) in contemporary practice. To assess the incidence and mechanism of LSD across commonly used DES platforms, we performed a case-by-case review of 1,800 PCI cases involving 450 consecutive procedures using Biomatrix Flex, Resolute Integrity, Promus Element, and Xience V stents, respectively, between January 2009 and December 2011. LSD was detected in a higher proportion with Promus Element [15 (3.1%)] compared with other platforms (Xience V [4 (0.9%)], Biomatrix [3 (0.7%)], Resolute [3 (0.7%)]; P = 0.002). LSD was characterized as guide catheter/guide extension induced, or as impact from secondary devices such as postdilatation balloons or IVUS catheters. The incidence of guide catheter/guide extension LSD was similar across platforms; (Promus Element [5 (1.1%)], Xience V [4 (0.9%)], Biomatrix [3 (0.7%)], Resolute [3 (0.7%)]; P = 0.85). Secondary device LSD occurred exclusively with Promus Element (9/450 cases [2%] (P stent was more difficult in cases of secondary device LSD (6/9 compared with 0/12 treated cases; P stent (OR 5.53 CI[1.54-19.85]), Guideliner use (OR 22.09 CI[4.73-103]), postdilation balloons (OR 5.47 CI[1.31-22.81]) and number of stents deployed (OR 2.06 CI[1.45-2.9]. LSD is more common than previously reported. LSD by a guide catheter/guide extension occurred equally with all platforms, however, LSD associated with secondary devices only occurred with the Element stent. These findings have important implications regarding current and future stent designs. © 2015 Wiley Periodicals, Inc.

  13. Design of the De-Orbit Sail Boom Deployment Unit

    Science.gov (United States)

    Meyer, Sebastian; Hillebrandt, Martin; Straubel, Marco; Huhne, Christian

    2014-06-01

    The design of the De-Orbit Sail boom deployment unit is strongly driven by volume constraints, which are given by the cubesat container. Four CFRP (carbon fiber reinforced polymer) booms [4] with a cross-sectional shape of a double-omega and a length of 3.6 m are reeled on one spool in the center of the unit. The deployment of the four booms are controlled by an electric motor, which acts on the boom spool. Due to the volume limitation caused by the dimensions of the cubesat deployer the deployment unit has little room for the mechanisms components. With the aim to achieve a robust design, the deployment concept of the unit has greatly changed during the development process. The history of the design as well as the mechanisms are described. Additionally the results of the flight model testing are presented.

  14. Self-expandable metallic stent as a bridge to elective surgery versus emergency surgery for acute malignant colorectal obstruction.

    Science.gov (United States)

    Li, Zhi-Xiong; Wu, Xiao-Hua; Wu, Hai-yan; Chang, Wen-Ju; Chang, Xiu-juan; Yi, Tuo; Shi, Qiang; Chen, Jing-Wen; Feng, Qing-Yang; Zhu, De-Xiang; Wei, Ye; Zhong, Yun-Shi; Xu, Jian-Min

    2016-03-01

    The efficacy and safety of self-expandable metallic stents (SEMSs) as a bridge for patients with acute malignant colorectal obstructions (AMCOs) are still controversial. We conducted this study to evaluate the outcomes of patients with AMCOs treated by different strategies. From January 2010 to March 2014, a total of 171 patients with AMCOs from Zhongshan Hospital were retrospectively enrolled in this study. One hundred twenty patients successfully received stent placement followed by one-stage laparoscopic or open resection in the stent group, and 51 patients received emergency operations in the emergency group. The operation duration and postoperative hospital stay were significantly shorter in the stent group (114.51 ± 28.65 vs. 160.39 ± 58.94 min, P stent group also had significantly reduced intraoperative blood loss and the incidence of postoperative complications compared with the emergency group (61.00 ± 43.70 vs. 121.18 ± 85.90 ml, P stent group was significantly longer than that in the emergency group (53 vs. 41 months, P = 0.034). In subgroup analysis of stent group, the stent laparoscopy group had significantly decreased postoperative complications (P = 0.025), and similar long-term survival (P = 0.81). Stent placement as a bridge to surgery is a safe and feasible procedure and provides significant advantages in terms of short-term outcomes and favorable prognoses for patients with AMCOs. Laparoscopic surgery could be considered as an optimal treatment after stent placement.

  15. A comparison of the temporary placement of 3 different self-expanding stents for the treatment of refractory benign esophageal strictures: a prospective multicentre study

    Directory of Open Access Journals (Sweden)

    Canena Jorge Manuel

    2012-06-01

    Full Text Available Abstract Background Refractory benign esophageal strictures (RBESs have been treated with the temporary placement of different self-expanding stents with conflicting results. We compared the clinical effectiveness of 3 types of stents: self-expanding plastic stents (SEPSs, biodegradable stents, and fully covered self-expanding metal stents (FCSEMSs, for the treatment of RBES. Methods This study prospectively evaluated 3 groups of 30 consecutive patients with RBESs who underwent temporary placement of either SEPSs (12 weeks, n = 10, biodegradable stents (n = 10 or FCSEMSs (12 weeks, n = 10. Data were collected to analyze the technical success and clinical outcome of the stents as evaluated by recurrent dysphagia, complications and reinterventions. Results Stent implantation was technically successful in all patients. Migration occurred in 11 patients: 6 (60% in the SEPS group, 2 (20% in the biodegradable group and 3 (30% in the FCSEMS group (P = 0.16. A total of 8/30 patients (26.6% were dysphagia-free after the end of follow-up: 1 (10% in the SEPS group, 3 (30% in the biodegradable group and 4 (40% in the FCSEMS group (P = 0.27. More reinterventions were required in the SEPS group (n = 24 than in the biodegradable group (n = 13 or the FCSEMS group (n = 13 (P = 0.24. Multivariate analysis showed that stricture length was significantly associated with higher recurrence rates after temporary stent placement (HR = 1.37; 95% CI = 1.08-1.75; P = 0.011. Conclusions Temporary placement of a biodegradable stent or of a FCSEMS in patients with RBES may lead to long-term relief of dysphagia in 30 and 40% of patients, respectively. The use of SEPSs seems least preferable, as they are associated with frequent stent migration, more reinterventions and few cases of long-term improvement. Additionally, longer strictures were associated with a higher risk of recurrence.

  16. Membranous obstruction of inferior vena cava(MOIVC): treatment with percutaneous transluminal angioplasty(PTA) and self expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki Yeol; Kim, Baek Hyun; Cha, In Ho; Lee, Nam Joon; Kim, Yun Hwan; Kim, Jung Hyuk [College of Medicine, Korea University, Seoul (Korea, Republic of)

    1994-03-15

    Percutaneous transluminal angioplasty(PTA) with a balloon catheter is a standard method of treatment for membranous obstruction of inferior vena cava(MOIVC). But, correct therapeutic approach has not been established for MOIVC patients whose lesion is associated with extensive thrombotic IVC occlusion. We tried to treat MOIVC associated with or without thrombus. We treated 13 cases of MOIVC(associated with thrombus in 7 cases, no thrombus in 6 cases) with PTA, thrombolysis and self-expandable metallic stents. PTA was successful in 8 cases, but failed in 5 cases. The recurred cases were retreated with PTA, but follow-up study revealed recoiling restenosis in 4 cases and intimal hyperplasia in 1 case at previous PTA site which could be overcome with a self-expandable metallic stent. The complication were occurred in 3 cases which were hemothorax, hemopericardium, and hemoperitoneum respectively. However, those were resolved by conservative treatment only. Recanalization and dilatation could be done in MOIVC patients with or without thrombosis for improvement of patient's symptom. Gianturco self-expandable metallic stent is useful in treatment of recurred MOIVC after balloon dilatation and preventing reocclusion of the IVC after PTA.

  17. Temporary self-expanding cardia stents for the treatment of achalasia: an experimental study in dogs

    International Nuclear Information System (INIS)

    Zhu Yueqi; Cheng Yingsheng; Li Minghua; Zhao Jungong; Li Feng; Chen Niwei

    2011-01-01

    Objective: To assess the performance, efficiency and optimal removal time of a newly designed temporary retrievable cardia covered stent (TRC-CS) for the treatment of achalasia in a dog model. Methods: Eighty-four achalasia-like dog models were randomly divided into seven groups of 12, a control group (CG; no stent insertion), a standard stent control group (NSCG, standard esophageal stent) and five treatment groups (TG, TRC-CS). Stents were retrieved at 4 days after insertion in the NSCG and at 4 days (4 d-TG), 2 weeks (2 w-TG), 1 month (1 m-TG), 3 months (3 m-TG), and 6 months (6 m-TG) in the TGs. lower esophageal sphincter pressure (LESP) and a timed barium esophagram were assessed before stent insertion, after stent retrieval, and at 1-week, 1-, 3- and 6-month follow-up. Three dogs in NSCG and 4 d-TG were sacrificed for histological examination at each follow-up to investigate the inflammatory reaction after stent insertion. Results: Stent insertion/removal and the follow-up procedures were well tolerated. At 6-month follow-up, the 2 w-TG and 1 m-TG demonstrated an acceptable stent migration (n=2 in both TGs versus n=4 in NSCG, n=4 in 3 m-TG, and =6 in 6 m-TG), improved LESP compared to after BAC injection (P<0.05), and improved timed barium height (p=0.0144 and 0.0409). Mouse-proliferating cell nuclear antigen (PCNA) and α-smooth muscle actin staining revealed no inflammatory reaction difference between the NSCG and 4d-TG at each follow-up. Conclusion: The TRC-CS was effective in the treatment of achalasia in a dog model. LESP measurements, timed barium esophagram studies suggest an optimal stent retrieval time of between 2 w∼1 m. (authors)

  18. A newly-designed temporary cardia stent for the treatment of achalasia:an experimental study in canine models

    International Nuclear Information System (INIS)

    Kuang Xiaochun; Cheng Yingsheng; Zhu Yueqi; Li Feng; Wang Weiguo

    2010-01-01

    Objective: To assess the efficacy and safety of a newly-designed temporary covered cardia stent for the treatment of achalasia in canine models and to investigate the histopathological changes at different points of follow-up time after the stent was removed. Methods: The canine achalasia model was created by injecting benzyl-dimethyl-tetradecyl ammonium chloride (BAC) circumferentially into the lower esophageal sphincter (LES) of the dogs. Twenty-four dogs with achalasia were randomly and equally divided into two groups with 12 dogs in each group: control group (using routine esophageal stents) and study group (using newly-designed temporary covered cardia stents). Under fluoroscopic guidance stents were implanted in the esophagus and were taken away from the esophagus 4 days after stent insertion in experimental dogs of both groups. LES pressures and timed barium esophagography (TBE) were performed in all dogs before and immediately after the stenting procedure, as well as at one week, 3 and 6 months after the stent was removed. Every three dogs were sacrificed each time at one week, 3 and 6 months after the stent was removed. The esophageal cardia was excised and sent for pathological examination. Results: All animals well tolerated the stent insertion / removal and the follow-up procedures. No severe complications such as esophageal perforation occurred. Comparison between two groups showed that stent migration occurrence was much lower in study group (n = 1) than that in control group (n = 5). The reduction of LES pressures in study group was more significant in comparison with control group (at 6-month follow-up, P = 0.027). The difference in barium column product (height x width) between 0-min and 5-min TBE was statistically significant in study group (at 3-month follow-up, P = 0.009). Integrated analysis of multi-comparison for LES pressures among subgroups of each group revealed that the dogs in study group exhibited better outcomes than the dogs in

  19. In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

    International Nuclear Information System (INIS)

    Huh, Young June; Choi, Bo Ram; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. The deviation of the entry point and angulation of the central axis in the reference plane were 0.47±0.27 mm, 0.57±0.23 mm, and 0.64±0.16 degree, 0.57±0.15 degree, respectively. However, for the two different angulations in each group, the 20 degree angulation showed a greater error in the deviation of the entry point than did the 10 degree angulation. The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

  20. Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature

    Directory of Open Access Journals (Sweden)

    Inderpaul Singh Sehgal

    2017-01-01

    Full Text Available Background: Airway obstruction or tracheoesophageal fistula (TEF near the tracheal carina requires placement of Y-shaped stents. Herein, we describe our multicenter experience with the placement of Dumon silicone Y-stents. We also conduct a systematic review for studies describing the deployment of airway silicone Y-stents. Methods: This was a retrospective analysis of consecutive subjects who underwent placement of silicone Y-stents. The clinical details including the underlying diagnosis, indication for the placement of silicone Y-stents, success of stent placement, and follow-up are presented. The PubMed and EMBASE databases were also reviewed for studies describing the placement of silicone Y-stents. Results: During the study, 27 silicone Y-stents were placed. The mean (standard deviation age of the study population (85.2% males was 57.7 (13.5 years. The stents were placed for airway obstruction in 77.8% and TEF in 29.6% of the patients. The most common underlying disease was carcinoma of the esophagus. The degree of airway obstruction was grade 3–4 in 18 subjects, and respiratory failure was encountered in 18 subjects. The stent was deployed successfully in all the subjects. No deaths were encountered during stent placement. Most subjects had rapid relief of symptoms following the procedure. Excessive secretions and mucostasis were the most common stent-related complications followed by the development of granulation tissue. The systematic review yielded nine studies (338 subjects with airway obstruction and/or TEF. The most common indication for silicone Y-stent placement was tracheobronchial obstruction and TEF due to malignancy. Benign disorders that necessitated stent placement included postintubation tracheal stenosis, airway malacia, and others. The stent was successfully placed in 98% with only one periprocedural death. Granulation tissue formation and mucostasis were the most common stent-related complications. Conclusion

  1. Percutaneous biliary drainage and stenting

    International Nuclear Information System (INIS)

    Totev, M.

    2012-01-01

    Full text: Percutaneous transhepatic cholangiography (PTC) is an X-ray or US guided procedure that involves the injection of a contrast material directly into the bile ducts inside the liver to produce pictures of them. If a blockage or narrowing is found, additional procedures may be performed: 1. insertion of a catheter to drain excess bile out of the body or both - internal and external; 2. plastic endoprothesis placement; 3. self-expandable metal stents placement to help open bile ducts or to bypass an obstruction and allow fluids to drain. Current percutaneous biliary interventions include percutaneous transhepatic cholangiography (PTC) and biliary drainage to manage benign and malignant obstructions. Internal biliary stents are either plastic or metallic, and various types of each kind are available. Internal biliary stents have several advantages. An external tube can be uncomfortable and have a psychological disadvantage. An internal stent prevents the problems related to external catheters, for example, pericatheter leakage of bile and the need for daily flushing. The disadvantages include having to perform endoscopic retrograde cholangiopancreatography (ERCP) or new PTC procedures to obtain access in case of stent obstruction. Better patency rates are reported with metallic than with plastic stents in cases of malignant obstruction, though no effect on survival is noted. Plastic internal stents are the cheapest but reportedly prone to migration. Metallic stents are generally not used in the treatment of benign disease because studies have shown poor long-term patency rates. Limited applications may include the treatment of patients who are poor surgical candidates or of those in whom surgical treatment fails. Most postoperative strictures are treated surgically, though endoscopic and (less commonly) percutaneous placement of nonmetallic stents has increasingly been used in the past few years. Now there are some reports about use of biodegradable biliary

  2. Fully covered stents versus partially covered stents for palliative treatment of esophageal cancer: Is there a difference?

    Science.gov (United States)

    Alonso Lárraga, J O; Flores Carmona, D Y; Hernández Guerrero, A; Ramírez Solís, M E; de la Mora Levy, J G; Sánchez Del Monte, J C

    2018-02-26

    Malignant dysphagia is difficulty swallowing resulting from esophageal obstruction due to cancer. The goal of palliative treatment is to reduce the dysphagia and improve oral dietary intake. Self-expandable metallic stents are the current treatment of choice, given that they enable the immediate restoration of oral intake. The aim of the present study was to describe the results of using totally covered and partially covered esophageal stents for palliating esophageal cancer. A retrospective study was conducted on patients with inoperable esophageal cancer treated with self-expandable metallic stents. The 2 groups formed were: group A, which consisted of patients with a fully covered self-expandable stent (SX-ELLA ® ), and group B, which was made up of patients with a partially covered self-expandable stent (Ultraflex ® ). Of the 69-patient total, 50 were included in the study. Group A had 19 men and 2 women and their mean age was 63.6 years (range 41-84). Technical success was achieved in 100% (n=21) of the cases and clinical success in 90.4% (n=19). Group B had 24 men and 5 women and their mean age was 67.5 years (range 43-92). Technical success was achieved in 100% (n=29) of the cases and clinical success in 89.6% (n=26). Complications were similar in both groups (33.3 vs. 51.7%). There was no difference between the 2 types of stent for the palliative treatment of esophageal cancer with respect to technical success, clinical success, or complications. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  3. MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Rasche, Volker [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, University of Ulm, Department of Internal Medicine II, Ulm (Germany); Oberhuber, Alexander; Orend, Karl-Heinz [University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Trumpp, Stephan [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Bornstedt, Axel; Merkle, Nico; Rottbauer, Wolfgang [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); Hoffmann, Martin [University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2011-07-15

    To evaluate the feasibility of MRI for static and dynamic assessment of the deployment of thoracic aortic stent grafts after emergency implantation in trauma patients. Twenty patients initially presenting with a rupture of the thoracic aorta were enrolled in this study. All patients underwent thoracic endovascular aortic repair (TEVAR). The deployment of the implanted stent graft was assessed by CTA and MRI, comprising the assessment of the aortic arch with and without contrast agent, and the assessment of the motion of the stent graft over the cardiac cycle. The stent graft geometry and motion over the cardiac cycle were assessable by MRI in all patients. Flow-mediated signal variations in areas of flow acceleration could be well visualised. No statistically significant differences in stent-graft diameters were observed between CT and MRI measurements. MRI appears to be a valuable tool for the assessment of thoracic stent grafts. It shows similar performance in the accurate assessment of stent-graft dimensions to the current gold standard CTA. Its capability of providing additional functional information and the lack of ionising radiation and nephrotoxic contrast agents may make MRI a valuable tool for monitoring patients after TEVAR. (orig.)

  4. Comparison between the STENTYS self-apposing bare metal and paclitaxel-eluting coronary stents for the treatment of saphenous vein grafts (ADEPT trial)

    NARCIS (Netherlands)

    A.J.J. IJsselmuiden (Alexander); C. Simsek (Cihan); Van Driel, A.G. (A. G.); Bouchez, D. (D.); G. Amoroso (Giovanni); P. Vermeersch (Paul); Karjalainen, P.P. (P. P.)

    2018-01-01

    textabstractAims To describe the safety and performance of STENTYS self-expandable bare metal stents (BMS) versus paclitaxel-eluting stents (PES) in saphenous vein grafts (SVGs). Methods and Results A randomised controlled trial was performed in four hospitals in three European countries between

  5. A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet Obstruction.

    Science.gov (United States)

    Takahara, Naminatsu; Isayama, Hiroyuki; Nakai, Yousuke; Yoshida, Shuntaro; Saito, Tomotaka; Mizuno, Suguru; Yagioka, Hiroshi; Kogure, Hirofumi; Togawa, Osamu; Matsubara, Saburo; Ito, Yukiko; Yamamoto, Natsuyo; Tada, Minoru; Koike, Kazuhiko

    2017-07-15

    Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.

  6. [Coronary stents: 30 years of medical progress].

    Science.gov (United States)

    Silvain, Johanne; Cayla, Guillaume; Collet, Jean-Philippe; Fargeot, Catherine; Montalescot, Gilles

    2014-03-01

    The history of interventional cardiology has been marked by several technologic revolutions since the late 1970s. The first key step was the use of inflatable balloon angioplasty as an alternative to CABG surgery for coronary revascularization, followed by intracoronary delivery of bare metal stent (BMS) and drug eluting stents (DES) to drastically reduce intracoronary restenosis observed with BMS. Improved stents platforms and polymers (absorbable or biocompatible) led to a dramatic reduction in the rate of late stent thrombosis. Self-expanding stents are now available to improve stent a position especially in acute myocardial infarction. The emergence of new fully bioabsorbable stents that can be combined with antiproliferative drugs is the ongoing revolution. A new generation of stents is continuously improving and likely to become the ideal stent for coronary revascularization in the near future. © 2014 médecine/sciences – Inserm.

  7. A newly designed Y-shaped covered stent in the palliative treatment of hepatic hilar malignant obstruction: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Chul; Lee, So Won [Dept. of Radiology, Mokdong Hospital, Ewha Womans University College of Medicine, Seoul (Korea, Republic of); Chung, Hwan Hoon [Dept. of Radiology, Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2013-01-15

    We report a case in an inoperable patient with the hilar malignant biliary obstruction treated palliatively by the use of a newly designed Y-shaped covered stent without interfering contra-lateral bile duct. We percutaneously inserted a newly designed Y-shaped covered stent into a biliary tree in an inoperable patient with Bismuth Type II cholangiocarcinoma. We checked tubograms, enhanced CT studies, and blood bilirubin levels before, one week after, and at every three month after the stenting, by observing closely the signs of clinical infection as well. The follow-up period was about 12 months. The placement of the Y-shaped covered stent was successful and resulted in adequate biliary drainage in the immediate post-procedural tubogram and in the follow-up abdominal CT. The serum bilirubin levels did not show elevation after the insertion of the Y-shaped covered stent.

  8. Partially Covered Metal Stents May Not Prolong Stent Patency Compared to Uncovered Stents in Unresectable Malignant Distal Biliary Obstruction

    Science.gov (United States)

    Kim, Jae Yun; Ko, Gyu Bong; Lee, Tae Hoon; Park, Sang-Heum; Lee, Yun Nah; Cho, Young Sin; Jung, Yunho; Chung, Il-Kwun; Choi, Hyun Jong; Cha, Sang-Woo; Moon, Jong Ho; Cho, Young Deok; Kim, Sun-Joo

    2017-01-01

    Background/Aims Controversy still exists regarding the benefits of covered self-expandable metal stents (SEMSs) compared to uncovered SEMSs. We aimed to compare the patency and stent-related adverse events of partially covered SEMSs (PC-SEMSs) and uncovered SEMSs in unresectable malignant distal biliary obstruction. Methods A total of 134 patients who received a PC-SEMS or uncovered SEMS for palliation of unresectable malignant distal biliary obstruction were reviewed retrospectively. The main outcome measures were stent patency, stent-related adverse events, and overall survival. Results The median stent patency was 118 days (range, 3 to 802 days) with PC-SEMSs and 105 days (range, 2 to 485 days) with uncovered SEMSs (p=0.718). The overall endoscopic revision rate due to stent dysfunction was 36.6% (26/71) with PC-SEMSs and 36.5% (23/63) with uncovered SEMSs (p=0.589). Tumor ingrowth was more frequent with uncovered SEMSs (4.2% vs 19.1%, p=0.013), but migration was more frequent with PC-SEMSs (11.2% vs 1.5%, p=0.04). The incidence of stent-related adverse events was 2.8% (2/71) with PC-SEMSs and 9.5% (6/63) with uncovered SEMSs (p=0.224). The median overall survival was 166 days with PC-SEMSs and 168 days with uncovered SEMSs (p=0.189). Conclusions Compared to uncovered SEMSs, PC-SEMSs did not prolong stent patency in unresectable malignant distal biliary obstruction. Stent migration was more frequent with PC-SEMSs. However, tumor ingrowth was less frequent with PC-SEMSs compared to uncovered SEMSs. PMID:28208003

  9. Evaluation of the 4-French Pulsar-18 Self-expanding Nitinol Stent in Long Femoropopliteal Lesions.

    Science.gov (United States)

    Lichtenberg, Michael; Hailer, Birgit; Kaeunicke, Matthias; Stahlhoff, Wilhelm-Friedrich; Boese, Dirk; Breuckmann, Frank

    2014-01-01

    To evaluate the patency and the freedom of target lesion revascularization of the 4-French Pulsar-18 self-expandable (SE) nitinol stent for the treatment of long femoropopliteal occlusive disease in a two-center, prospective, all-comers registry with a follow-up period of 12 months. This registry enrolled 36 patients with symptomatic femoropopliteal long lesions for recanalization and implantation of the 4-French Pulsar-18 SE nitinol stent. Routine follow-up examination including duplex ultrasound was performed after 6 and 12 months. Primary patency was defined as no binary restenosis on duplex ultrasound (Peak systolic velocitiy ration (PSVR) Pulsar-18 SE nitinol stent for endovascular intervention of femoropopliteal disease with a mean lesion length of 182.3 ± 51.8 mm showed promising primary patency and fTLR rates after 6 and 12 months. Diabetes and renal insufficiency had no negative impact on the patency rate.

  10. Partially covered versus uncovered self-expandable nitinol stents with anti-migration properties for the palliation of malignant distal biliary obstruction: A randomized controlled trial.

    Science.gov (United States)

    Yang, Min Jae; Kim, Jin Hong; Yoo, Byung Moo; Hwang, Jae Chul; Yoo, Jun Hwan; Lee, Ki Seong; Kang, Joon Koo; Kim, Soon Sun; Lim, Sun Gyo; Shin, Sung Jae; Cheong, Jae Youn; Lee, Kee Myung; Lee, Kwang Jae; Cho, Sung Won

    2015-01-01

    Covered self-expandable metal stents (SEMSs) are increasingly used as alternatives to uncovered SEMSs for the palliation of inoperable malignant distal biliary obstruction to counteract tumor ingrowth. We aimed to compare the outcomes of partially covered and uncovered SEMSs with identical mesh structures and anti-migration properties, such as low axial force and flared ends. One hundred and three patients who were diagnosed with inoperable malignant distal biliary obstruction between January 2006 and August 2013 were randomly assigned to either the partially covered (n = 51) or uncovered (n = 52) SEMS group. There were no significant differences in the cumulative stent patency, overall patient survival, stent dysfunction-free survival and overall adverse events, including pancreatitis and cholecystitis, between the two groups. Compared to the uncovered group, stent migration (5.9% vs. 0%, p = 0.118) and tumor overgrowth (7.8% vs. 1.9%, p = 0.205) were non-significantly more frequent in the partially covered group, whereas tumor ingrowth showed a significantly higher incidence in the uncovered group (5.9% vs. 19.2%, p = 0.041). Stent migration in the partially covered group occurred only in patients with short stenosis of the utmost distal bile duct (two in ampullary cancer, one in bile duct cancer), and did not occur in any patients with pancreatic cancer. For the palliation of malignant distal biliary obstruction, endoscopic placement of partially covered SEMSs with anti-migration designs and identical mesh structures to uncovered SEMSs failed to prolong cumulative stent patency or reduce stent migration.

  11. Predictors of outcomes in patients undergoing covered and uncovered self-expandable metal stent placement for malignant gastric outlet obstruction: a multicenter study.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-02-01

    Uncovered self-expandable metal stents (U-SEMSs) and covered self-expandable metal stents (C-SEMSs) are available for palliative therapy for malignant gastric outlet obstruction (GOO). However, clinical differences and indications between the 2 types of SEMSs have not been elucidated. We retrospectively compared 126 patients with U-SEMS and 126 patients with C-SEMSs with regard to clinical outcome and factors predictive of clinical improvement after SEMSs placement. No significant difference was observed between the U-SEMS and C-SEMS groups with respect to technical success, clinical success, GOO score, or time to stent dysfunction. Stent migration was significantly more frequent in patients with C-SEMSs (U-SEMSs, .79%; C-SEMSs, 8.73%; P = .005). Karnofsky performance status, chemotherapy, peritoneal dissemination, and stent expansion ≤ 30% were associated significantly with poor GOO score improvement in multivariable analyses, but stent type was not (P = .213). In subgroup analyses, insufficient (≤30%) stent expansion was an independent factor in patients with U-SEMSs (P = .041) but not C-SEMSs. In the insufficient stent expansion subgroup, C-SEMSs was associated significantly with superior clinical improvement compared with U-SEMSs (P = .01). Insufficient stent expansion was observed more frequently in patients with GI obstruction because of anastomotic sites or metastatic cancer (44.8% [13/29], P = .001). No clinical difference, apart from stent migration, was observed between patients with U-SEMSs and C-SEMSs. GI obstruction because of an anastomotic site or metastatic cancer may be an indication for C-SEMS use to improve oral intake after SEMSs placement. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  12. Full covered self-expandable metal stents for the treatment of anastomotic leak using a silk thread.

    Science.gov (United States)

    Choi, Cheol Woong; Kang, Dae Hwan; Kim, Hyung Wook; Park, Su Bum; Kim, Su Jin; Hwang, Sun Hwi; Lee, Si Hak

    2017-07-01

    To evaluate the safety and effectiveness of fixation of the fully covered self-expandable metal stent (SEMS) placement using a silk thread for complete closure of an anastomotic leak. An anastomotic leak is a life-threatening complication after gastrectomy. Although the traditional treatment of choice was surgical re-intervention, an endoscopic SEMS can be used alternatively.During the study period, we retrospectively reviewed consecutive patients who received a modified covered SEMS capable of being fixed using a silk thread (Shim technique) due to an anastomotic leak after gastrectomy to prevent stent migration. Demographic data, stent placement and removal, clinical success, time to resolution, and complications were evaluated.A total of 7 patients underwent fully covered SEMS with a silk thread placement for an anastomotic leak after gastrectomy to treat gastric cancer. The patients' mean age was 71.3 ± 8.0 years. Man sex was predominant (85.7%). All patients' American Society of Anesthesiologists (ASA) scores were between I and III. Total gastrectomy was performed in 5 patients (71.4%) and proximal gastrectomy was performed in 2 patients (28.6%). The time between gastrectomy and stent insertion was 22.3 ± 11.1 days. The size of the leaks was 27.1 ± 11.1 mm. Technical success and complete leak closure were achieved in all patients. Stent migration was absent. All stents were removed between 4 and 6 weeks. Delayed esophageal stricture was found in 1 patient (14.2) and successfully resolved after endoscopic balloon dilation.For an anastomotic leak after gastrectomy, fully covered SEMS placement with a silk thread is an effective and safe treatment option without stent migration. The stent extraction time between 4 and 6 weeks was optimal without severe complications.

  13. Palliative self-expandable metal stents for acute malignant colorectal obstruction: clinical outcomes and risk factors for complications.

    Science.gov (United States)

    Han, Jae Pil; Hong, Su Jin; Kim, Shin Hee; Choi, Jong Hyo; Jung, Hee Jae; Cho, Youn Hee; Ko, Bong Min; Lee, Moon Sung

    2014-08-01

    Self-expandable metal stents (SEMSs) have been used as palliative treatment or bridge to surgery for obstructions caused by colorectal cancer (CRC). We assessed the long-term outcomes of palliative SEMSs and evaluated the risk factors influencing complications. One hundred and seventy-five patients underwent SEMS placement for acute malignant colorectal obstruction. Of the 72 patients who underwent palliative treatment for primary CRC, 30 patients received chemotherapy (CT) for primary cancer (CT group) and 42 underwent best supportive treatment (BST) without CT (BST group). There was a significant difference in late migration between the CT group and the BST group (20.0% in CT group, 2.4% in BST group, p = 0.018). Response to CT influenced the rate of late obstruction (0% in disease control, 35.7% in disease progression, p = 0.014). However, late obstruction was not associated with stent properties, such as diameter or type (≤22 mm vs. >22 mm, 13.5% vs. 14.3%, p = 1.00; uncovered stent vs. covered stent, 15.5% vs. 7.1%, p = 0.675) and migration (≤22 mm vs. >22 mm, 16.2% vs. 2.9%, p = 0.108; uncovered stent vs. covered stent, 8.6% vs. 14.3%, p = 0.615) in palliative SEMS. The administration of CT increases the rate of stent migration, and disease control by CT can reduce the risk of obstruction by maintaining the luminal patency of palliative SEMSs.

  14. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; Rauws, Erik A. J.; Fockens, Paul; van Hooft, Jeanin E.

    2015-01-01

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that

  15. A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study

    Directory of Open Access Journals (Sweden)

    Teeuwen Koen

    2012-12-01

    Full Text Available Abstract Background Percutaneous recanalization of total coronary occlusion (TCO was historically hampered by high rates of restenosis and reocclusions. The PRISON II trial demonstrated a significant restenosis reduction in patients treated with sirolimus-eluting stents compared with bare metal stents for TCO. Similar reductions in restenosis were observed with the second-generation zotarolimus-eluting stent and everolimus-eluting stent. Despite favorable anti-restenotic efficacy, safety concerns evolved after identifying an increased rate of very late stent thrombosis (VLST with drug-eluting stents (DES for the treatment of TCO. Late malapposition caused by hypersensitivity reactions and chronic inflammation was suggested as a probable cause of these VLST. New DES with bioresorbable polymer coatings were developed to address these safety concerns. No randomized trials have evaluated the efficacy and safety of the new-generation DES with bioresorbable polymers in patients treated for TCO. Methods/Design The prospective, randomized, single-blinded, multicenter, non-inferiority PRISON IV trial was designed to evaluate the safety, efficacy, and angiographic outcome of hybrid sirolimus-eluting stents with bioresorbable polymers (Orsiro; Biotronik, Berlin, Germany compared with everolimus-eluting stents with durable polymers (Xience Prime/Xpedition; Abbott Vascular, Santa Clara, CA, USA in patients with successfully recanalized TCOs. In total, 330 patients have been randomly allocated to each treatment arm. Patients are eligible with estimated duration of TCO ≥4 weeks with evidence of ischemia in the supply area of the TCO. The primary endpoint is in-segment late luminal loss at 9-month follow-up angiography. Secondary angiographic endpoints include in-stent late luminal loss, minimal luminal diameter, percentage of diameter stenosis, in-stent and in-segment binary restenosis and reocclusions at 9-month follow-up. Additionally, optical coherence

  16. Temporary urethral covered stent - third year of experience

    International Nuclear Information System (INIS)

    Stojanovis, V.; Maksimovis, H.; Markovis, B.; Markovis, Z.

    2006-01-01

    Full text: In October 2003, a new generation of urethral stents ALLIUM, produced in Israel, were used at the Department of Interventional Radiology, CCS, in 18 patients with chronic stricture of bulbar urethra. The indications for insertion were determined according to well-known and recognized therapeutical protocols. The stent is made of nitinol wire with polyurethane cover. It is inserted under local anesthesia by a special self-expandable system that may be fixed or flexible. The stents we used were 3-6 cm long and 28 Fr wide. Radioscopic-assisted insertion was performed over formerly placed metal guide. Prior to insertion, balloon-catheter dilatation of stricture matching the stent width was carried out. Pre-insertion urethrotomy was performed in one case. The insertion technique is simple, presupposing the knowledge of older generations of techniques of urethral dilatation and insertion of self-expandable stents. The follow-up of results was done according to a priori established protocol including the following: UCG, uroflowmetry and interview with patients. Due to stent migration, the 'stent over stent' technique was applied in one case, while reposition by balloon-catheter outward traction was performed in two cases of caudal migration. No irritative discomforts were reported in the first 4 months after stent dwelling. Uroflowmetric controls verified at least four times better results than before the insertion. Given it is the question of covered stent, there is no possibility of proliferative secondary lumen obstruction. On account of soft structure and conic shape of posterior part of stent, no lesions of the external urethral sphincter were manifested. The stent is simply withdrawn after 6 months by outward traction using the forceps at the time when the stent construction turns into soft and straight wire. The first clinical experiences are very favorable and ALLIUM stent may be expected to be the stent of choice for chronic bulbar strictures

  17. Stent insertion in patients with malignant biliary obstruction: problems of the Hanaro stent

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jae Hyun; Seong, Chang Kyu; Shin, Tae Beom; Kim, Yong Joo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of); Jung, Gyoo Sik [School of Medicine, Kosin National Univ., Pusan (Korea, Republic of); Park, Byeung Ho [School of Medicine, Donga National Univ., Pusan (Korea, Republic of)

    2002-07-01

    To investigate the problems of the Hanaro stent (Solco Intermed, Seoul, Korea) when used in the palliative treatment of patients with inoperable malignant biliary obstruction. Between January 2000 and May 2001, the treatment of 46 patients with malignant biliary obstruction involved percutaneous placement of the Hanaro stent. Five patients encountered problems during removal of the stent's introduction system. The causes of obstruction were pancreatic carcinoma (n=2), cholangiocarcinoma (n=2), and gastric carcinoma with biliary invasion (n=1). In one patient, percutaneous transhepatic cholangiography and stent insertion were performed as a one-step procedure, while the others underwent conventional percutaneous transhepatic biliary drainage for at least two days prior to stent insertion. A self-expandable Hanaro stent, 8-10 mm in deameter and 50-100 mm in lengh, and made from a strand of nitinol wire, was used in all cases. Among the five patients who encountered problems, breakage of the olive tip occourred in three, upward displacement of the stent in two, and improper expansion of the distal portion of the stent, unrelated with the obstruction site, in one. The broken olive tip was pushed to the duodenum in two cases and to the peripheral intrahepatic duct in one. Where the stent migrated during withdrawal of its introduction system, an additional stent was inserted. In one case, the migrated stent was positioned near the liver capsule and the drainage catheter could not be removed. Although the number of patients in this study was limited, some difficulties were encountered in withdrawing the stent's introduction system. To prevent the occurrence of this unusual complication, the stent should be appropriately expansile, and shape in the olive tip should be considered.

  18. Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats

    Directory of Open Access Journals (Sweden)

    Olavo Ribeiro Rodrigues

    2013-01-01

    Full Text Available PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.

  19. Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Sedat, Jacques; Chau, Yves; Mondot, Lydiane [CHU Nice, Unite de Neurointerventionnelle, Hopital St. Roch, Nice (France); Vargas, Julian; Szapiro, Jacek; Lonjon, Michel [CH Bastia, Service de Neurochirurgie, Bastia (France)

    2009-06-15

    Coiling associated with placement of self-expandable intracranial stents has amplified the treatment of intracranial wide-necked aneurysms, but the durability of this treatment and the existence of delayed recurrence are not yet well known. The purpose of this report is to present our experience with the Neuroform Stent associated with coiling and to evaluate complications, effectiveness, and long-term results of this technique. A retrospective study of 42 patients with wide-necked cerebral aneurysms treated with the Neuroform Stent was performed. Mean aneurysm size was 11.3 mm. Mean neck size was 5.33 mm. All patients were treated with coiling and stenting. Clinical and angiographic follow-up was available in 38 patients (90.5%). The overall follow-up time ranged from 6 months to 5 years (mean, 42 months), but most of the patients (92%) had a follow-up period superior to 1 year. Successful deployment of 41 stents (97%) was obtained. Permanent procedural morbidity was observed in only one patient (2.4%). Long-term complete aneurysmal occlusion was obtained in 27 patients (71%). Aneurysmal regrowth was observed in four patients (9.5%) on the first control angiogram. After the first control angiogram, no delayed recanalization or regrowth was observed. During the follow-up period, there were no hemorrhagic events, no delayed thrombosis, and no stent displacement. Our results demonstrate the effectiveness of the technique, a small rate of procedural complications, and long-term tolerance of the Neuroform Stent. Despite some evidence of early aneurysmal recurrence, long-term durability of stent-assisted aneurysm occlusion is stable after the first year. (orig.)

  20. Migrated esophageal stent posing a challenge for ventilation

    Directory of Open Access Journals (Sweden)

    Nita D'souza

    2017-01-01

    Full Text Available Self-expandable esophageal stents are being commonly used for palliative treatment in advanced esophageal cancer patients to relieve dysphagia, prevent tracheoesophageal fistula, and facilitate symptomatic betterment. The modern covered stents reduce the ingrowth of the tumor but have seen an increase in the incidence of stent migrations. We report a rather complicated presentation of an esophageal stent for esophageal dilatation and a challenging management of a difficult tracheostomy.

  1. Delayed Development of Brain Abscesses Following Stent-Graft Placement in a Head and Neck Cancer Patient Presenting with Carotid Blowout Syndrome

    International Nuclear Information System (INIS)

    Oweis, Yaseen; Gemmete, Joseph J.; Chaudhary, Neeraj; Pandey, Aditya; Ansari, Sameer

    2011-01-01

    We describe the delayed development of intracranial abscesses following emergent treatment with a covered stent-graft for carotid blowout syndrome (CBS) in a patient with head and neck cancer. The patient presented with hemoptysis and frank arterial bleeding through the tracheostomy site. A self-expandable stent-graft was deployed across a small pseudoaneurysm arising from the right common carotid artery (RCCA) and resulted in immediate hemostasis. Three months later, the patient suffered a recurrent hemorrhage. CT of the neck demonstrated periluminal fluid around the caudal aspect of the stent-graft with intraluminal thrombus and a small pseudoaneurysm. Subsequently, the patient underwent a balloon test occlusion study and endovascular sacrifice of the RCCA and right internal carotid artery. MRI of the brain demonstrated at least four ring-enhancing lesions within the right cerebral hemisphere consistent with intracranial abscesses that resolved with broad-spectrum antibiotic coverage.

  2. In-stent stenosis after stent-assisted coiling: incidence, predictors and clinical outcomes of 435 cases.

    Science.gov (United States)

    Chalouhi, Nohra; Drueding, Ross; Starke, Robert M; Jabbour, Pascal; Dumont, Aaron S; Gonzalez, L Fernando; Rosenwasser, Robert; Tjoumakaris, Stavropoula

    2013-03-01

    Neuroform and Enterprise are widely used self-expanding stents designed to treat wide-necked intracranial aneurysms. To assess the incidence, clinical significance, predictors, and outcomes of in-stent stenosis (ISS). Angiographic studies and hospital records were retrospectively reviewed for 435 patients treated between 2005 and 2011 in our institution. A multivariable regression analysis was conducted to determine the predictors of ISS. The Neuroform stent was used in 264 patients (60.7%) and the Enterprise in 171 patients (39.3%). A total of 11 patients (2.5%) demonstrated some degree of ISS during the follow-up period at a mean time point of 4.2 months (range, 2-12 months). The stenosis was mild ( 75%) in 1 patient (0.2%). No patients were symptomatic or required further intervention. There was complete ISS resolution in 2 patients, partial resolution in 2 patients, and no change in 5 patients on follow-up angiography. Patients developing ISS were significantly younger than those without ISS (40.3 vs. 54.9 years; P stent (P = .6). In multivariable analysis, younger patient age (odds ratio = 0.92; P = .008), carotid ophthalmic aneurysm location (odds ratio = 7.7; P =0.01), and carotid terminus aneurysm location (odds ratio = 8.1; P = .009) were strong independent predictors of ISS. The type of stent was not a predictive factor. Neuroform and Enterprise ISS is an uncommon, often transient, and clinically benign complication. Younger patients and those harboring anterior circulation aneurysms located at ophthalmic and carotid terminus locations are more likely to develop ISS.

  3. Endoscopic stent suture fixation for prevention of esophageal stent migration during prolonged dilatation for achalasia treatment.

    Science.gov (United States)

    Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F

    2017-04-01

    The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. "Stent" auto-expansível nas dissecções da aorta tipo B Self-expanding stent in type B dissections of the aorta

    Directory of Open Access Journals (Sweden)

    Wagner Michael PEREIRA

    1999-07-01

    Full Text Available O tratamento clínico das dissecções agudas da aorta do tipo B tem mortalidade em torno de 25% menor que a mortalidade cirúrgica. O tratamento cirúrgico das dissecções crônicas também produz uma morbidade e mortalidade elevadas. A utilização de "stents"auto-expansíveis endovasculares pode ser uma nova alternativa no tratamento destas lesões. De abril a dezembro de 1998 foram implantados 15 "stents" endovasculares, 10 em dissecções agudas e 5 em crônicas. A idade dos pacientes variou entre 48 e 75 anos (média=60,53±9,73 anos com 66,6% do sexo masculino. Os pacientes foram submetidos à esternotomia mediana, circulação extracorpórea (CEC com hipotermia profunda (18° - 20°C, parada circulatória total (PCT e perfusão cerebral retrógrada (PCR. A aorta transversa foi incisada e implantado o "stent" na aorta descendente sob auxílio de aortoscopia. Foram analisados os tempos de CEC, pinçamento aórtico, PCT, PCR, reaquecimento, ventilação mecânica, internação, sangramento trans e pós-operatório, reposição sangüínea, gasometria, curva de eventos e sobrevida. A mortalidade hospitalar (30 dias foi de 6,6%; 2 pacientes foram reoperados com 3 e 6 meses após a operação com dissecção da aorta ascendente e aneurisma roto distal ao "stent". Quatorze vêm sendo acompanhados com 1 a 8m de evolução, sendo que 85,7% estão livres de eventos e curva de sobrevida de 93,1%(240 dias. Concluímos que o implante de "stent"intraluminais auto-expansíveis apresentou mortalidade menor na fase aguda da doença (6,6% comparada à nossa experiência anterior com o tratamento clínico (30%. Apesar da amostra ser pequena, o procedimento parece ser promissor e necessita mais acompanhamento.The clinical treatment of acute type B aortic dissection has a mortality of about 25%, therefore, less than surgical mortality. The surgical treatment of chronic dissections also produces a high morbidity and mortality. The use of self

  5. SU-E-T-115: Dose Perturbation Study of Self-Expandable Metal and Polyester Esophageal Stents in Proton Therapy Beams

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Li, Z [University of Florida Proton Therapy Institute, Jacksonville, FL (United States); Jalaj, S; McGaw, C; B K, John; J S, Scolapio; J C, Munoz [Division of Gastoenterology, Department of Medicine, University of Florida, Jacksonville, FL (United States)

    2014-06-01

    Purpose: This work investigates dose perturbations due to Self-expandable metal and polyester esophageal stents undergoing proton radiotherapy for esophageal cancer. Methods: Five commercially available esophageal stents made of nitinol (Evolution, Wallflex and Ultraflex), stainless steel (Z-Stent) and polyester (Polyflex) were tested. Radiochromic film (GafChromic EBT3 film, Ashland, Covington, KY) wrapped around a stent and a 12cc syringe was irradiated with 2CGE (Cobalt Gray Equivalent) of proton beam in a custom fabricated acrylic phantom. An air-hollow syringe simulates the esophagus. Results: The Z-stent created the largest dose perturbations ranges from -14.5% to 6.1% due to the steel composition. The WallFlex, Evolution and Ultraflex stents produced the dose perturbation ranges of (−9.2%∼8.6%), (−6.8%∼5.7%) and (−6.2%∼6.2%), respectively. The PolyFlex stent contains the radiopaque tungsten markers located top, middle and bottom portions. When the focal cold spots induced by the markers were excluded in the analysis, the dose perturbation range was changed from (−11.6%∼6.4%) to (−0.6%∼5.0%). Conclusion: The magnitude of dose perturbation is related to material of a metallic stent. The non-metallic stent such as PolyFlex shows relatively lower dose perturbation than metallic stents except a radiopaque marker region. Overall Evolution and Ultraflex stent appear to be less dose perturbations. The largest dose perturbations (cold spots) were located at both edges of stents in distal area for the single proton beam irradiation study. The analysis of more than two proton beam which is more typical clinical beam arrangement would be necessary to minimize the doe perturbation effect in proton ratiotherapy.

  6. Temporary stenting and retrieval of the self-expandable, intracranial stent in acute middle cerebral artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Sang Hyun; Chung, Tae-Sub [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea); Lee, Kyung-Yul [Yonsei University College of Medicine, Department of Neurology, Gangnam Severance Hospital, Seoul (Korea); Hong, Chang Ki; Kim, Chang-Hyun [Yonsei University College of Medicine, Department of Neurosurgery, Gangnam Severance Hospital, Seoul (Korea); Kim, Byung Moon; Kim, Dong Ik [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea)

    2009-08-15

    We describe our experience in which a retrievable Enterprise stent was used as a temporary recanalization and embolectomy device in an acute middle cerebral artery (MCA) occlusion after urgent stenting for ipsilateral carotid artery stenosis. (orig.)

  7. A non-randomized study in consecutive patients with postcholecystectomy refractory biliary leaks who were managed endoscopically with the use of multiple plastic stents or fully covered self-expandable metal stents (with videos).

    Science.gov (United States)

    Canena, Jorge; Liberato, Manuel; Meireles, Liliane; Marques, Inês; Romão, Carlos; Coutinho, António Pereira; Neves, Beatriz Costa; Veiga, Pedro Mota

    2015-07-01

    Endoscopic management of postcholecystectomy biliary leaks is widely accepted as the treatment of choice. However, refractory biliary leaks after a combination of biliary sphincterotomy and the placement of a large-bore (10F) plastic stent can occur, and the optimal rescue endotherapy for this situation is unclear. To compare the clinical effectiveness of the use of a fully covered self-expandable metal stent (FCSEMS) with the placement of multiple plastic stents (MPS) for the treatment of postcholecystectomy refractory biliary leaks. Prospective study. Two tertiary-care referral academic centers and one general district hospital. Forty consecutive patients with refractory biliary leaks who underwent endoscopic management. Temporary placement of MPS (n = 20) or FCSEMSs (n = 20). Clinical outcomes of endotherapy as well as the technical success, adverse events, need for reinterventions, and prognostic factors for clinical success. Endotherapy was possible in all patients. After endotherapy, closure of the leak was accomplished in 13 patients (65%) who received MPS and in 20 patients (100%) who received FCSEMSs (P = .004). The Kaplan-Meier (log-rank) leak-free survival analysis showed a statistically significant difference between the 2 patient populations (χ(2) [1] = 8.30; P stents (P = .024), a plastic stent diameter <20F (P = .006), and a high-grade biliary leak (P = .015) were shown to be significant predictors of treatment failure with MPS. The 7 patients in whom placement of MPS failed were retreated with FCSEMSs, resulting in closure of the leaks in all cases. Non-randomized design. In our series, the results of the temporary placement of FCSEMSs for postcholecystectomy refractory biliary leaks were superior to those from the use of MPS. A randomized study is needed to confirm our results before further recommendations. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  8. Endoscopic suture fixation is associated with reduced migration of esophageal fully covered self-expandable metal stents (FCSEMS).

    Science.gov (United States)

    Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan

    2017-09-01

    Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.

  9. Ultrathin endoscope-assisted self-expandable metallic stent placement following initial unsuccessful attempt in malignant upper gastrointestinal obstruction.

    Science.gov (United States)

    Park, Se Woo; Lee, Hyuk; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2014-03-01

    Conventional endoscopy for self-expandable metallic stent (SEMS) placement may be technically limited in long and tortuous strictures. Therefore, we analyzed the feasibility, safety and usefulness of ultrathin endoscopy (UTE)-guided SEMS placement. This study involved 24 patients with upper gastrointestinal obstruction and unsuccessful initial attempts to place SEMS using conventional endoscopy. After completely passing a UTE across the stricture, the UTE was withdrawn, leaving a guidewire placed via the working channel. Through-the-scope SEMS placement was done using a conventional endoscope inserted along the guidewire. The primary endpoints were assessed by technical/clinical success and stent patency duration. Stents were successfully placed at target locations in all but one case with a long tortuous stricture, with 95.8% (23/24) technical success. One week after stent placement, mean gastricoutlet obstruction score improved significantly from baseline (1.74 ± 0.62 and 0.33 ± 0.48, respectively; P Stent migration, restenosis, and fracture occurred in four (17.4%), six (26.1%), and one (4.3%) of 23 stents, respectively. Median stent patency duration was 79 days. Mean stent patency was significantly longer in patients who received palliative chemotherapy than in those who did not (122.9 ± 11.0 and 38.3 ± 4.6, respectively; P < 0.001). UTE guidance SEMS delivery can be a feasible and safe rescue treatment method for malignant upper gastrointestinal obstruction in cases of failed attempts to place SEMS using conventional endoscopy. Our result warrants a further study to define the efficacy of this method in difficult SEMS placement cases. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  10. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    Science.gov (United States)

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  11. Silicone covered vs. Non- covered endotracheal self expandable metallic stent: An experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Do, Young Soo; Lee, Byung Hee; Kim, Soo Ah; Kim, Kie Hwan; Chin, Soo Yil; Cho, Kyung Ja; Cho, Dae Soon [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1994-10-15

    To evaluate pathologic changes of the trachea and the lung after insertion of silicone covered and non covered Gianturco stent in the trachea of dog. Silicone covered(covered) and non covered(bare) Gianturco stent, six in each, were inserted into the tracheal lumen of six consecutive dogs. After 1-10 weeks observation, the dogs were sacrificed and their tracheas and lungs were examined grossly and histopathologically. Serial chest radiographs were performed to evaluate pneumonia and stent migration every 3-5 days. Pneumonia was observed in one of bare stent group and five of covered stent group. Stent migration was noted in three of covered stent group. In bare stent group, the epithelium of the trachea was markedly thickened by hyperplasia and stent was covered by granulation tissue from 6 weeks after stent insertion. Inflammation was focal at contact site between the stent and the trachea. In covered stent group, the epithelium was denuded at multiple areas and there were multifocal squamous metaplasia of the mucosa. Inflammatory reaction of the trachea was diffuse. Inflammatory reaction was more severe and stent migration was more frequent in covered stent group. The use of covered stent in the trachea should be studied further.

  12. Stent implantation for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation

    International Nuclear Information System (INIS)

    Xing Ming; Yang Pengfei; Huang Qinghai; Zhao Wenyuan; Hong Bo; Xu Yi; Liu Jianmin

    2012-01-01

    Objective: To preliminarily evaluate the feasibility, safety and efficacy of stent placement for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation. Methods: Eleven patients with wide-necked aneurysms located at internal carotid artery bifurcation, who were encountered during the period from Jan. 2004 to Dec. 2010 in hospital, were collected. A total of 16 intracranial aneurysms were detected, of which 11 were wide-necked and were located at internal carotid artery bifurcation. The diameters of the aneurysms ranged from 2.5 mm to 18 mm. Individual stent type and stenting technique was employed for each patient. Follow-up at 1, 3, 6 and 12 months after the procedure was conducted. Results: A total of 11 different stents were successfully deployed in the eleven patients. The stents included balloon expandable stent (n=1) and self-expanding stent (n=10). According to Raymond grading for the immediate occlusion of the aneurysm, grade Ⅰ (complete obliteration) was obtained in 4, grade Ⅱ (residual neck) in 2 and grade Ⅲ (residual aneurysm) in 5 cases. No procedure-related complications occurred. At the time of discharge, the modified Rankin score was 0-1 in the eleven patients. During the follow-up period lasting for 1-108 months, all the patients were in stable condition and no newly-developed neurological dysfunction or bleeding observed. Follow-up examination with angiography (1-48 months) showed that the aneurysms were cured (no visualization) in 4 cases, improved in 2 cases and in stable condition in one case. Conclusion: For the treatment of wide-necked aneurysms located at internal carotid artery bifurcation, stent implantation is clinically feasible, safe and effective. Further studies are required to evaluate its long-term efficacy. (authors)

  13. A US Multicenter Study of Safety and Efficacy of Fully Covered Self-Expandable Metallic Stents in Benign Extrahepatic Biliary Strictures.

    Science.gov (United States)

    Saxena, Payal; Diehl, David L; Kumbhari, Vivek; Shieh, Frederick; Buscaglia, Jonathan M; Sze, Wilson; Kapoor, Sumit; Komanduri, Srinadh; Nasr, John; Shin, Eun Ji; Singh, Vikesh; Lennon, Anne Marie; Kalloo, Anthony N; Khashab, Mouen A

    2015-11-01

    Endoscopic therapy is considered first line for management of benign biliary strictures (BBSs). Placement of plastic stents has been effective but limited by their short-term patency and need for repeated procedures. Fully covered self-expandable metallic stents (FCSEMSs) offer longer-lasting biliary drainage without the need for frequent exchanges. The aim of this study was to assess the efficacy and safety of FCSEMS in patients with BBS. A retrospective review of all patients who underwent ERCP and FCSEMS placement at five tertiary referral US hospitals was performed. Stricture resolution and adverse events related to ERCP and/or stenting were recorded. A total of 123 patients underwent FCSEMS placement for BBS and 112 underwent a subsequent follow-up ERCP. The mean age was 62 years (±15.6), and 57% were males. Stricture resolution occurred in 81% of patients after a mean of 1.2 stenting procedures (mean stent dwell time 24.4 ± 2.3 weeks), with a mean follow-up of 18.5 months. Stricture recurrence occurred in 5 patients, and 3 patients required surgery for treatment of refractory strictures. Stent migration (9.7%) was the most common complication, followed by stent occlusion (4.9%), cholangitis (4.1%), and pancreatitis (3.3%). There was one case of stent fracture during removal, and one stent could not be removed. There was one death due to cholangitis. Majority of BBS can be successfully managed with 1-2 consecutive FCSEMS with stent dwell time of 6 months.

  14. Enterprise stenting for intracranial aneurysm treatment induces dynamic and reversible age-dependent stenosis in cerebral arteries.

    Science.gov (United States)

    Gao, Bulang; Safain, Mina G; Malek, Adel M

    2015-04-01

    Although intracranial stenting has been associated with in-stent stenosis, the vascular response of cerebral vessels to the deployment of the Enterprise vascular reconstruction device is poorly defined. To evaluate the change in parent vessel caliber that ensues after Enterprise stent placement. Seventy-seven patients with 88 aneurysms were treated using Enterprise stent-assisted coil embolization and underwent high-resolution three-dimensional rotational angiography followed by three-dimensional edge-detection filtering to remove windowing-dependence measurement artifact. Orthogonal diameters and cross-sectional areas (CSAs) were measured proximal and distal on either side of the leading stent edge (points A, B), trailing stent edge (points D, E), and at mid-stent (point C). Enterprise stent deployment caused an instant increase in the parent artery CSA by 8.98% at D, which was followed 4-6 months later by significant in-stent stenosis (15.78% at A, 27.24% at B, 10.68% at C, 32.12% at D, and 28.28% at E) in the stented artery. This time-dependent phenomenon showed resolution which was complete by 12-24 months after treatment. This target vessel stenosis showed significant age dependence with greater response in the young. No flow-limiting stenosis requiring treatment was observed in this series. Use of the Enterprise stent is associated with a significant dynamic and spontaneously resolvable age-dependent in-stent stenosis. Further study is warranted on the clinical impact, if any, of this occurrence. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Chee, Hyun Keun; Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chang, Seong Hwan; Jung, Hong Geun [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-04-15

    We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint

  16. A comparative reliability and performance study of different stent designs in terms of mechanical properties: foreshortening, recoil, radial force, and flexibility.

    Science.gov (United States)

    Kim, Dong Bin; Choi, Hyuk; Joo, Sang Min; Kim, Han Ki; Shin, Jae Hee; Hwang, Min Ho; Choi, Jaesoon; Kim, Dong-Gon; Lee, Kwang Ho; Lim, Chun Hak; Yoo, Sun Kook; Lee, Heung-Man; Sun, Kyung

    2013-04-01

    This study seeks to improve the mechanical performance of stents by conducting reliability performance testing and finite element method (FEM)-based simulations for coronary stents. Three commercially available stent designs and our own new design were tested to measure the factors affecting performance, specifically foreshortening, recoil, radial force, and flexibility. The stents used in the present experiments were 3 mm in working diameter and 18 mm of working length. The results of the experiments indicate that the foreshortening of stents A, B, C, and our new design, D, was equivalent to 2.25, 0.67, 0.46, and 0.41%, respectively. The recoil of stents A, B, C, and D was 6.00, 4.35, 3.50, and 4.36%, respectively. Parallel plate radial force measurements were A, 3.72 ± 0.28 N; B, 3.81 ± 0.32 N; C, 4.35 ± 0.18 N; and D, 4.02 ± 0.24 N. Radial forces determined by applying uniform pressure in the circumferential direction were A, 28.749 ± 0.81 N; B, 32.231 ± 1.80 N; C, 34.522 ± 3.06 N; and D, 42.183 ± 2.84 N. The maximum force of crimped stent at 2.2-mm deflection was 1.01 ± 0.08 N, 0.82 ± 0.08 N, 0.92 ± 0.12 N, and 0.68 ± 0.07 N for each of stents A, B, C and D. The results of this study enabled us to identify several factors to enhance the performance of stents. In comparing these stents, we found that our design, stent D, which was designed by a collaborative team from seven universities, performed better than the commercial stents across all parameter of foreshortening, recoil, radial force, and flexibility. © 2013, Copyright the Authors. Artificial Organs © 2013, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention

    Directory of Open Access Journals (Sweden)

    Chang-Il Kwon

    2016-03-01

    Full Text Available Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs] have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations.

  18. Enterprise stent for waffle-cone stent-assisted coil embolization of large wide-necked arterial bifurcation aneurysms.

    Science.gov (United States)

    Padalino, David J; Singla, Amit; Jacobsen, Walter; Deshaies, Eric M

    2013-01-01

    Large wide-necked arterial bifurcation aneurysms present a unique challenge for endovascular coil embolization treatment. One technique described in the literature deploys a Neuroform stent into the neck of the aneurysm in the shape of a waffle-cone, thereby acting as a scaffold for the coil mass. This case series presents four patients with large wide-necked bifurcation aneurysms treated with the closed-cell Enterprise stent using the waffle-cone technique. Four patients (59 ± 18 years of age) with large wide-necked arterial bifurcation aneurysms (three basilar apex and one MCA bifurcation) were treated with the waffle-cone technique using the Enterprise stent as a supporting device for stent-assisted coil embolization. Three of the patients presented with aneurysmal subarachnoid hemorrhage (Hunt-Hess 2-3; Fisher Grade 3-4). There was no procedural morbidity or mortality associated with treatment itself. One aneurysm was completely obliterated, and three had small residual necks. One patient developed an area of PCA infarct and visual field cut one month after the procedure and required recoiling of the residual neck. The flared ends of the Enterprise stent remodeled the aneurysm neck by conforming to the shape of the neck without any technical difficulty, resulting in a stable scaffold holding the coils into the aneurysm. The closed cell construction, flexibility, and flared ends of the Enterprise stent allow it to conform to the waffle-cone configuration and provide a stable scaffold for coil embolization of large wide-necked arterial bifurcation aneurysms. We have had excellent initial results using the Enterprise stent with the waffle-cone technique. However, this technique is higher risk than standard treatment methods and therefore should be reserved for large wide-necked bifurcation aneurysms where Y stenting is needed, but not possible, and surgical clip ligation is not an option.

  19. An approach to tracheostomy in a patient with an expandable metallic tracheal stent.

    Science.gov (United States)

    Madden, Brendan P; Sheth, Abhijat

    2005-09-01

    With increasing use of expandable metallic stents to manage patients with a variety of endobronchial pathologies, some will have a subsequent need for tracheostomy insertion. We describe a successful technique to insert a tracheostomy using rigid and fibre-optic bronchoscopy in a patient who had an 8 cm expandable metallic tracheal stent deployed previously on account of tracheomalacia.

  20. Iliocaval Confluence Stenting for Chronic Venous Obstructions

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Rick de, E-mail: r.de.graaf@mumc.nl [Maastricht University Medical Centre (MUMC), Department of Radiology (Netherlands); Wolf, Mark de, E-mail: markthewolf@gmail.com [Maastricht University Medical Centre (MUMC), Department of Surgery (Netherlands); Sailer, Anna M., E-mail: anni.sailer@mumc.nl [Maastricht University Medical Centre (MUMC), Department of Radiology (Netherlands); Laanen, Jorinde van, E-mail: jorinde.van.laanen@mumc.nl; Wittens, Cees, E-mail: c.wittens@me.com [Maastricht University Medical Centre (MUMC), Department of Surgery (Netherlands); Jalaie, Houman, E-mail: hjalaie@ukaachen.de [University Hospital Aachen, Department of Surgery (Germany)

    2015-10-15

    PurposeDifferent techniques have been described for stenting of venous obstructions. We report our experience with two different confluence stenting techniques to treat chronic bi-iliocaval obstructions.Materials and MethodsBetween 11/2009 and 08/2014 we treated 40 patients for chronic total bi-iliocaval obstructions. Pre-operative magnetic resonance venography showed bilateral extensive post-thrombotic scarring in common and external iliac veins as well as obstruction of the inferior vena cava (IVC). Stenting of the IVC was performed with large self-expandable stents down to the level of the iliocaval confluence. To bridge the confluence, either self-expandable stents were placed inside the IVC stent (24 patients, SECS group) or high radial force balloon-expandable stents were placed at the same level (16 patients, BECS group). In both cases, bilateral iliac extensions were performed using nitinol stents.ResultsRecanalization was achieved for all patients. In 15 (38 %) patients, a hybrid procedure with endophlebectomy and arteriovenous fistula creation needed to be performed because of significant involvement of inflow vessels below the inguinal ligament. Mean follow-up was 443 ± 438 days (range 7–1683 days). For all patients, primary, assisted-primary, and secondary patency rate at 36 months were 70, 73, and 78 %, respectively. Twelve-month patency rates in the SECS group were 85, 85, and 95 % for primary, assisted-primary, and secondary patency. In the BECS group, primary patency was 100 % during a mean follow-up period of 134 ± 118 (range 29–337) days.ConclusionStenting of chronic bi-iliocaval obstruction shows relatively high patency rates at medium follow-up. Short-term patency seems to favor confluence stenting with balloon-expandable stents.

  1. Endoscopic management of complications of self-expandable metal stents for treatment of malignant esophageal stenosis and tracheoesophageal fistulas.

    Science.gov (United States)

    Bor, Renáta; Fábián, Anna; Bálint, Anita; Farkas, Klaudia; Szűcs, Mónika; Milassin, Ágnes; Czakó, László; Rutka, Mariann; Molnár, Tamás; Szepes, Zoltán

    2017-08-01

    Self-expandable metal stent (SEMS) implantation may rapidly improve the symptoms of malignant esophageal stenosis and tracheoesophageal fistulas (TEF). However, dysphagia often returns subsequently and repeated endoscopic intervention may be necessary. The aims of the study were to identify the risk factors of complications, and the frequency and efficacy of repeated endoscopic interventions; and to provide technical recommendations on appropriate stent selection. We analyzed retrospectively the clinical data of 212 patients with locally advanced esophageal cancer who underwent SEMS implantation. A total of 238 SEMS implantations were performed with 99.06% technical success and 1.26% procedure-related deaths in the enrolled 212 cases. Complications occurred in 84 patients (39.62%) and in 55 cases (25.94%) repeated endoscopic procedures were required. Early reintervention 24-48 h after the stent implantations was necessary due to stent migration (12 cases), arrhythmia (2 cases), intolerable retrosternal pain (1 case) and dyspnea (1 case). An average of 1.98 repeated gastroscopies (range 1-6; median 2), 13.58 weeks (range 1.5-48; median 11) after the stent implantation were performed during the follow-up period: 37 stent repositions, 23 restent implantations, 15 endoscopic esophageal dilations and 7 stent removals. In 48 cases (87.3%) oral feeding of patients was made possible by endoscopic interventions. In a quarter of SEMS implantations, complications occur that can be successfully managed by endoscopic interventions. Our experiences have shown that individualized stent choice may substantially reduce the complications rate and make repeated endoscopic interventions easier.

  2. New stent design for use in small coronary arteries during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Juan F Granada

    2010-10-01

    Full Text Available Juan F Granada1, Barbara A Huibregtse2, Keith D Dawkins21The Jack H Skirball Center for Cardiovascular Research, Cardiovascular Research Foundation, Columbia University Medical Center, New York, NY, USA; 2Boston Scientific Corporation, Natick, MA, USAAbstract: Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel, and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches, intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001, instent binary restenosis (13.0% versus 38.1%, P < 0.001, and target lesion revascularization (5.8% versus 17.6%, P < 0.001 at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03 and instent binary restenosis (13.0% versus 25.9%, P = 0.02 when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS

  3. Basic Knowledge about Metal Stent Development

    Directory of Open Access Journals (Sweden)

    Seok Jeong

    2016-03-01

    Full Text Available Biliary self-expandable metal stents (SEMS, a group of non-vascular stents, have been used in the palliative management of biliary obstruction around the world. However, there are still unmet needs in the clinical application of biliary SEMS. Comprehensive understanding of the SEMS is required to resolve the drawbacks and difficulties of metal stent development. The basic structure of SEMS, including the materials and knitting methods of metal wires, covering materials, and radiopaque markers, are discussed in this review. What we know about the physical and mechanical properties of the SEMS is very important. With an understanding of the basic knowledge of metal stents, hurdles such as stent occlusion, migration, and kinking can be overcome to develop more ideal SEMS.

  4. Self-expandable metal stents for relieving malignant colorectal obstruction: short-term safety and efficacy within 30 days of stent procedure in 447 patients.

    Science.gov (United States)

    Meisner, Søren; González-Huix, Ferran; Vandervoort, Jo G; Goldberg, Paul; Casellas, Juan A; Roncero, Oscar; Grund, Karl E; Alvarez, Alberto; García-Cano, Jesús; Vázquez-Astray, Enrique; Jiménez-Pérez, Javier

    2011-10-01

    The self-expandable metal stent (SEMS) can alleviate malignant colonic obstruction and avoid emergency decompressive surgery. To document performance, safety, and effectiveness of colorectal stents used per local standards of practice in patients with malignant large-bowel obstruction to avoid palliative stoma surgery in incurable patients (PAL) and facilitate bowel decompression as a bridge to surgery for curable patients (BTS). Prospective clinical cohort study. Two global registries with 39 academic and community centers. This study involved 447 patients with malignant colonic obstruction who received stents (255 PAL, 182 BTS, 10 no indication specified). Colorectal through-the-scope SEMS placement. The primary endpoint was clinical success at 30 days, defined as the patient's ability to maintain bowel function without adverse events related to the procedure or stent. Secondary endpoints were procedural success, defined as successful stent placement in the correct position, symptoms of persistent or recurrent colonic obstruction, and complications. The procedural success rate was 94.8% (439/463), and the clinical success rates were 90.5% (313/346) as assessed on a per protocol basis and 71.6% (313/437) as assessed on an intent-to-treat basis. Complications included 15 (3.9%) perforations, 3 resulting in death, 7 (1.8%) migrations, 7 (1.8%) cases of pain, and 2 (0.5%) cases of bleeding. No control group. No primary endpoint analysis data for 25% of patients. This largest multicenter, prospective study of colonic SEMS placement demonstrates that colonic SEMSs are safe and highly effective for the short-term treatment of malignant colorectal obstruction, allowing most curable patients to have 1-step resection without stoma and providing most incurable patients minimally invasive palliation instead of surgery. The risk of complications, including perforation, was low. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All

  5. Experimental absorbable stent permits airway remodeling.

    Science.gov (United States)

    Liu, Kuo-Sheng; Liu, Yun-Hen; Peng, Yi-Jie; Liu, Shih-Jung

    2011-02-01

    Despite metallic and silicone stents being effective in treating various airway lesions, many concerns still remain. A bioresorbable stent that scaffolds the airway lumen and dissolves after the remodeling process is completed has advantages over metallic and silicone stents. We designed and fabricated a new mesh-type bioresorbable stent with a backbone of polycaprolactone (PCL), and evaluated its safety and biocompatibility in a rabbit trachea model. The PCL stent was fabricated by a laboratory-made microinjection molding machine. In vitro mechanical strength of the PCL stents was tested and compared to that of commercial silicone stents. The bioresorbable stents were surgically implanted into the cervical trachea of New Zealand white rabbits (n=6). Animals received bronchoscopic examination at 1, 2, 4, 8, and 12 weeks after surgery. Histological examination was completed to evaluate the biocompatibility of the stents. No animals died during the period of study. Distal stent migration was noted in 1 rabbit. In-stent secretion accumulation was found in 2 rabbits. Histological examination showed intact ciliated epithelium and marked leukocyte infiltration in the submucosa of the stented area at 10 and 28 weeks. Stent degradation was minimal, and the mechanical strength was well preserved at the end of 33 weeks. These preliminary findings showed good safety and biocompatibility of the new PCL stent when used in the airway remodeling. PCL could be a promising bioresorbable material for stent design if prolonged degradation time is required. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. Self-expandable metal stents for malignant esophageal obstruction: a comparative study between extrinsic and intrinsic compression.

    Science.gov (United States)

    Rhee, K; Kim, J-H; Jung, D H; Han, J W; Lee, Y C; Lee, S K; Shin, S K; Park, J C; Chung, H S; Park, J J; Youn, Y H; Park, H

    2016-04-01

    Self-expandable metal stents (SEMSs) are effective for malignant esophageal obstruction, but usefulness of SEMSs in extrinsic lesions is yet to be elucidated. This study is aimed at evaluating the clinical usefulness of SEMSs in the extrinsic compression compared with intrinsic. A retrospective review was conducted for 105 patients (intrinsic, 85; extrinsic, 20) with malignant esophageal obstruction who underwent endoscopic SEMSs placement. Technical and clinical success rates were evaluated and clinical outcomes were compared between extrinsic and intrinsic group. Extrinsic group was mostly pulmonary origin. Overall technical and clinical success rate was 100% and 91%, respectively, without immediate complications. Extrinsic and intrinsic group did not differ significantly in clinical success rate. The median stent patency time was 131.3 ± 85.8 days in intrinsic group while that of extrinsic was 54.6 ± 45.1 due to shorter survival after stent insertion. The 4-, 8-, and 12-week patency rates were 90.5%, 78.8%, and 64.9% respectively in intrinsic group, while stents of extrinsic group remained patent until death. Uncovered, fully covered, and double-layered stent were used evenly and the types did not influence patency in both groups. In conclusion, esophageal SEMSs can safely and effectively be used for malignant extrinsic compression as well as intrinsic. © 2015 International Society for Diseases of the Esophagus.

  7. Endoscopically placed nitinol stents for pediatric tracheal obstruction.

    Science.gov (United States)

    Prasad, Mukesh; Bent, John P; Ward, Robert F; April, Max M

    2002-11-11

    To provide preliminary clinical data regarding endoscopically placed nitinol stents for children with tracheal obstruction as a temporizing measure to allow for trach tube decannulation while awaiting growth to allow for tracheal resection. This case series describes the experiences of two children (ages 5 and 15) who were dependent upon tracheotomy because of acquired tracheal obstruction. Both patients had combined tracheomalacia and tracheal stenosis. After failing tracheoplasty with rib graft augmentation both patients suffered from extensive tracheal disease, which was too long to allow for immediate tracheal resection. Endoscopic placement of nitinol stents in the obstructed tracheal segment using fluoroscopic guidance. All tracheotomy tubes were removed immediately after successful stent deployment with the patient still under general anesthesia. Four stents were placed in total. The first patient's initial stent was too narrow and was, therefore, removed and replaced at a later date with a larger diameter stent. The second patient experienced distal migration of his initial stent requiring stent removal and replacement at a later date. Both patients remain successfully decannulated (follow-up, 25 and 26 months) and are currently living more normal lives as they grow and await tracheal resection. Preliminary use of nitinol stents for pediatric tracheal obstruction has enabled successful decannulation in two children with complicated airways. Our results with this series of patients suggest that nitinol stents can be safely used in children as a temporizing measure until tracheal resection can be safely performed. With this approach children can live free from the hassles of trach care, social isolation and peer ridicule. Limited pediatric experience exists in the literature about nitinol stents. Thus, our experience with stent selection and placement will help others avoid problems encountered in this initial series. Copyright 2002 Elsevier Science Ireland

  8. Preliminary clinical application in the cranial internal carotid artery of covered stents specially designed for intracranial vasculature

    International Nuclear Information System (INIS)

    Li Minghua; Luo Qiyi; Fang Chun; Xie Zhiyong; Cheng Yingsheng; Gao Bulang; Li Yu; Zhang Beilei; Xie Jian; Wang Yongli

    2007-01-01

    Objective: To investigate the flexibility of both the covered stents specially designed for use in intracranial vasculature and the delivering system in passing through the bone tube and the physiological curves of the cranial internal carotid artery (CICA) to reach the targeted area, the performance (adherence) of the covered stents in occluding vascular wall diseases and the impact on the vascular branches of the covered segment. Methods: The covered stents specially designed for use in intracranial vasculature were used to treat 13 patients with CICA diseases using endovascular techniques. There were 4 huge pseudoaneurysms, 4 giant aneurysms, 3 small wide-necked aneurysms, 1 giant pseudoaneurysm with concurrent internal carotid cavernous fistula (CCF), and 1 CCF. Prior to the detachment of the covered stents, balloon occlusion test (BOT) of the internal carotid artery on the diseased side and whole-brain digital subtraction angiography (DSA) were performed in all the patients. Three to 16 months following procedure, DSA and clinical follow-ups were performed. Results: Thirteen patients all tolerated the BOT well with the DSA demonstrating well-opened anterior and posterior communicating arteries. The covered stents and the delivering systems all successfully passed CICA to reach the targeted diseased area, with the diseased segments of the internal carotid artery including C3-C4 in 4 cases, C4-C5 in 4 and C6-C7 in 5. Immediately following the detachment of the covered stents, DSA demonstrated that 7 aneurysms were completely occluded, 4 aneurysms had slight endoleak, and 1 CCF had markedly-decreased blood flow through the fistula. In the patient with concurrent pseudoaneurysm and CCF, the pseudoaneurysm disappeared and the blood flow through the fistula was markedly-reduced immediately following the stenting procedure. Apart from one patient with aneurysmal subarachnoid hemorrhage who died due to extensive vascular spasm on the 9th day following the stenting

  9. Expandable stents.

    Science.gov (United States)

    Nesbitt, J C; Carrasco, H

    1996-05-01

    tissue is less likely to occur in areas of established scar than in areas of acute inflammation. In circumstances in which it is essential that a stent remain only temporarily, an expandable stent should not be inserted in favor of a silicone stent, which can be removed. In the future, expandable stents may have silicone coverings or may be constructed of materials that facilitate removal. Until that time, expandable stents should be considered permanent and nonremovable. Subtle differences exist among the available stents. Standard is low-profile expandable construction from wire mesh. A relatively minor difference is the slightly wider expansibility of the Gianturco stent, a quality that makes it the best suited of the three stents for lesions that involve tracheomalacia. Perhaps the only major difference between the Wallstent and the Gianturco and Palmaz stents is its better ability to conform to tortuous lesions. In an acutely angled stricture, a Wallstent offers a better opportunity for successful placement than other stents. The filamentous meshwork of the Wallstent allows it to bend and conform better to distorted airways. The Gianturco and Palmaz stents have little longitudinal elasticity, which makes them less effective in a tortuous or highly angulated airway stenosis. Expandable stents have demonstrated their efficacy and exposed their limitations in the treatment of airway stenoses. Refinements in design should help to lessen specific disadvantages and problems. Covered expandable stents, a realistic prospect, have specific advantages over standard expandable stents; they will be removable and prevent tumor ingrowth. Current investigative work with such prostheses for the vascular system may provide the foundation for their investigative use in the airway. In essence, two categories of expandable stents are evolving, covered and uncovered, each having unique features adaptable to the specific clinical needs.

  10. Comparison on the Efficacy between Partially Covered Self-Expandable Metal Stent with Funnel-Shaped Enlarged Head versus Uncovered Self-Expandable Metal Stent for Palliation of Gastric Outlet Obstruction

    Directory of Open Access Journals (Sweden)

    Jung Wan Choe

    2018-01-01

    Full Text Available Background. Shape modification has been one of the methods adopted to improve stent patency but has not always translated into positive outcome. The aim of this study was to compare the efficacy of shape-modified partially covered self-expandable metal stent (SEMS that has enlarged head versus uncovered SEMS for palliation of gastric outlet obstruction (GOO. Methods. A total of 48 patients underwent insertion of either enlarged-head SEMS (n=24 or uncovered SEMS (uSEMS (n=24 for palliation of GOO from July 2009 to July 2016. Patients with inoperable or advanced malignancy were included. Technical feasibility and clinical outcomes were compared. Results. Technical success rate was 100% (24/24 and 95.8% (23/24 for enlarged-head SEMS group and uSEMS group, respectively. Clinical success rate was 87.5% (21/24 and 87.0% (20/23 for enlarged-head SEMS group and uSEMS group, respectively. The gastric outlet obstruction scoring system score significantly improved in both groups (p<0.001 for both. Mean survival was similar between the groups: enlarged-head SEMS group, 99.3 days (range, 19–358 days versus uSEMS group, 82.1 days (range, 11–231 days (p=0.418. The mean stent patency also showed no difference between the groups: enlarged-head SEMS group, 87.1 days (range, 8–358 days versus uSEMS group, 60.4 days (range, 2–231 days (p=0.204. With enlarged-head SEMS, distal migration did not occur, but proximal migration was observed in four cases. Conclusions. Distal migration was prevented by shaping the SEMS to have an enlarged head, but improvement in stent patency could not be observed.

  11. Impact on outcome of different types of carotid stent: results from the European Registry of Carotid Artery Stenting.

    Science.gov (United States)

    Stabile, Eugenio; Giugliano, Giuseppe; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitrios; Sannino, Anna; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Rubino, Paolo; Esposito, Giovanni; Tesorio, Tullio

    2016-06-12

    Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk.

  12. Keeping engaged during deployment : The interplay between self-efficacy, family support, and threat exposure

    NARCIS (Netherlands)

    Delahaij, R.; Kamphuis, W.; Berg, C.E. van den

    2016-01-01

    This study investigated the importance of 2 resilience resources for service members’ ability to deal with threat during deployment. Military self-efficacy and family support were measured before deployment and related to work engagement and burnout levels of service members during deployment. We

  13. Application of High Entropy Alloys in Stent Implants

    Science.gov (United States)

    Alagarsamy, Karthik

    High entropy alloys (HEAs) are alloys with five or more principal elements. Due to these distinct concept of alloying, the HEA exhibits unique and superior properties. The outstanding properties of HEA includes higher strength/hardness, superior wear resistance, high temperature stability, higher fatigue life, good corrosion and oxidation resistance. Such characteristics of HEA has been significant interest leading to researches on these emerging field. Even though many works are done to understand the characteristic of these HEAs, very few works are made on how the HEAs can be applied for commercial uses. This work discusses the application of High entropy alloys in biomedical applications. The coronary heart disease, the leading cause of death in the United States kills more than 350,000 persons/year and it costs $108.9 billion for the nation each year in spite of significant advancements in medical care and public awareness. A cardiovascular disease affects heart or blood vessels (arteries, veins and capillaries) or both by blocking the blood flow. As a surgical interventions, stent implants are deployed to cure or ameliorate the disease. However, the high failure rate of stents has lead researchers to give special attention towards analyzing stent structure, materials and characteristics. Many works related to alternate material and/or design are carried out in recent time. This paper discusses the feasibility of CoCrFeNiMn and Al0.1CoCrFeNi HEAs in stent implant application. This work is based on the speculation that CoCrFeNiMn and Al0.1CoCrFeNi HEAs are biocompatible material. These HEAs are characterized to determine the microstructure and mechanical properties. Computational modeling and analysis were carried out on stent implant by applying CoCrFeNiMn and Al0.1CoCrFeNi HEAs as material to understand the structural behavior.

  14. Esophagojejunal Anastomosis Fistula, Distal Esophageal Stenosis, and Metalic Stent Migration after Total Gastrectomy

    Directory of Open Access Journals (Sweden)

    Nadim Al Hajjar

    2015-01-01

    Full Text Available Esophagojejunal anastomosis fistula is the main complication after a total gastrectomy. To avoid a complex procedure on friable inflamed perianastomotic tissues, a coated self-expandable stent is mounted at the site of the anastomotic leak. A complication of stenting procedure is that it might lead to distal esophageal stenosis. However, another frequently encountered complication of stenting is stent migration, which is treated nonsurgically. When the migrated stent creates life threatening complications, surgical removal is indicated. We present a case of a 67-year-old male patient who was treated at our facility for a gastric adenocarcinoma which developed, postoperatively, an esophagojejunostomy fistula, a distal esophageal stenosis, and a metallic coated self-expandable stent migration. To our knowledge, this is the first reported case of an esophagojejunostomy fistula combined with a distal esophageal stenosis as well as with a metallic coated self-expandable stent migration.

  15. Clinical outcomes with the STENTYS self-apposing coronary stent in patients presenting with ST-segment elevation myocardial infarction: two-year insights from the APPOSITION III (A Post-Market registry to assess the STENTYS self-exPanding COronary Stent In AcuTe MyocardIal InfarctiON) registry.

    Science.gov (United States)

    Lu, Huangling; Grundeken, Maik J; Vos, Nicola S; IJsselmuiden, Alexander J J; van Geuns, Robert-Jan; Wessely, Rainer; Dengler, Thomas; La Manna, Alessio; Silvain, Johanne; Montalescot, Gilles; Spaargaren, René; Tijssen, Jan G P; Amoroso, Giovanni; de Winter, Robbert J; Koch, Karel T

    2017-08-04

    The APPOSITION III registry evaluated the feasibility and performance of the STENTYS self-apposing stent in an ST-segment elevation myocardial infarction (STEMI) population. This novel self-apposing stent device lowers stent strut malapposition rates and therefore carries the potential to prevent stent undersizing during primary percutaneous coronary intervention (PCI) in STEMI patients. To date, no long-term data are available using this device in the setting of STEMI. We aimed to evaluate the long-term clinical outcomes of the APPOSITION III registry. This was an international, prospective, multicentre post-marketing registry. The study population consisted of 965 STEMI patients. The primary endpoint, major adverse cardiac events (MACE), was defined as the composite of cardiac death, recurrent target vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularisation (CD-TLR). At two years, MACE occurred in 11.2%, cardiac death occurred in 2.3%, TV-MI occurred in 2.3% and CD-TLR in 9.2% of patients. The two-year definite stent thrombosis (ST) rate was 3.3%. Incremental event rates between one- and two-year follow-up were 1.0% for TV-MI, 1.8% for CD-TLR, and 0.5% for definite ST. Post-dilation resulted in significantly reduced CD-TLR and ST rates at 30-day landmark analyses. Results were equivalent between the BMS and PES STENTYS subgroups. This registry revealed low rates of adverse events at two-year follow-up, with an incremental ST rate as low as 0.5% in the second year, demonstrating that the self-apposing technique is feasible in STEMI patients on long-term follow-up while using post-dilatation.

  16. Long-term safety and outcome of a temporary self-expanding metallic stent for achalasia: a prospective study with a 13-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jun-Gong; Li, Yong-Dong; Li, Ming-Hua; Shang, Ke-Zhong [Shanghai Tong Ji University, Department of Radiology, Tenth Affiliated People' s Hospital, Shanghai (China); Cheng, Ying-Sheng [Shanghai Tong Ji University, Department of Radiology, Tenth Affiliated People' s Hospital, Shanghai (China); Shanghai Jiao Tong University, Department of Radiology, Sixth Affiliated People' s Hospital, Shanghai (China); Chen, Ni-Wei; Chen, Wei-Xiong [Shanghai Jiao Tong University, Department of Gastroenterology, Sixth Affiliated People' s Hospital, Shanghai (China)

    2009-08-15

    To prospectively evaluate the long-term clinical safety and efficacy of a newly designed self-expanding metallic stent (SEMS) in the treatment of patients with achalasia. Seventy-five patients with achalasia were treated with a temporary SEMS with a 30-mm diameter. The SEMSs were placed under fluoroscopic guidance and removed by gastroscopy 4-5 days after stent placement. Follow-up data focused on dysphagia score, technique and clinical success, clinical remissions and failures, and complications and was performed at 6 months, 1 year, and within 3 to 5 years, 5 to 8 years, 8 to 10 years, and >10 years postoperatively. Stent placement was technically successful in all patients. Complications included stent migration (n=4, 5.33%), chest pain (n=28, 38.7%), reflux (n=15, 20%), and bleeding (n=9, 12%). No perforation or 30-day mortality occurred. Clinical success was achieved in all patients 1 month after stent removal. The overall remission rates at 6 months, 1, 1-3, 3-5, 5-8, 8-10, and >10 year follow-up periods were 100%, 96%, 93.9%, 90.9%, 100%, 100%, and 83.3%, respectively. Stent treatment failed in six patients, and the overall remission rate in our series was 92%. The median and mean primary patencies were 2.8 {+-} 0.28 years (95% CI: 2.25-3.35) and 4.28 {+-} 0.40 years (95% CI: 3.51-5.05), respectively. The use of temporary SEMSs with 30-mm diameter proved to be a safe and effective approach for managing achalasia with a long-term satisfactory clinical remission rate. (orig.)

  17. Metallic stent placement in hemodialysis graft patients after insufficient balloon dilation

    International Nuclear Information System (INIS)

    Liang, Huei-Lung; Pan, Huay-Ben; Lin, Yih-Huie; Chen, Chiung-Yu; Lai, Pin-Hong; Yang, Chien-Fang; Chung, Hsiao-Min; Wu, Tung-Ho; Chou, Kang-Ju

    2006-01-01

    We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. Twenty-three patients (13 loop grafts in the forearm and 10 straight grafts in the upper arm) underwent metallic stent placement due to insufficient flow after urokinase thrombolysis and balloon dilation. The indications for metallic stent deployment included 1) recoil and/or kinked venous stenosis in 21 patents (venous anastomosis: 17 patients, peripheral outflow vein: four patients); and 2) major vascular rupture in two patients. Metallic stents 8-10mm in diameter and 40-80 mm in length were used. Of them, eight stents were deployed across the elbow crease. Access patency was determined by clinical follow-up and the overall rates were calculated by Kaplan-Meier survival analysis. No procedure-related complications (stent fracture or central migration) were encountered except for a delayed Wallstent shortening/migration at the venous anastomosis, which resulted in early access failure. The overall primary and secondary patency rates (±standard error) of all the vascular accesses in our 23 patients at 3, 6, 12 and 24 months were 69%±9 and 88%±6,41% ±10 and 88%±6, 30%±10 and 77%±10, and 12%±8 and 61%±13, respectively. For the forearm and upper-arm grafts, the primary and secondary patency rates were 51%±16 and 86%±13 vs 45%±15 and 73%±13 at 6 months, and 25%±15 and 71%±17 vs 23%±17 and 73%±13 at 12 months (ρ = .436 and .224), respectively. Metallic stent placement is a safe and effective means for treating peripheral venous lesions in dialysis graft patients after insufficient balloon dilation. No statistically difference in the patency rates between the forearm and upper-arm patient groups was seen

  18. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  19. First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

    Science.gov (United States)

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-05-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  20. First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

    International Nuclear Information System (INIS)

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H.; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M.; Borm, Paul J. A.; Jacob, Augustinus L.; Bilecen, Deniz

    2009-01-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  1. Outcomes of the Use of Fully Covered Esophageal Self-Expandable Stent in the Management of Colorectal Anastomotic Strictures and Leaks

    Directory of Open Access Journals (Sweden)

    Chad J. Cooper

    2014-01-01

    Full Text Available Introduction. Colorectal anastomotic leak or stricture is a dreaded complication leading to significant morbidity and mortality. The novel use of self-expandable metal stents (SEMS in the management of postoperative colorectal anastomotic leaks or strictures can avoid surgical reintervention. Methods. Retrospective study with particular attention to the indications, operative or postoperative complications, and clinical outcomes of SEMS placement for patients with either a colorectal anastomotic stricture or leak. Results. Eight patients had SEMS (WallFlex stent for the management of postoperative colorectal anastomotic leak or stricture. Five had a colorectal anastomotic stricture and 3 had a colorectal anastomotic leak. Complete resolution of the anastomotic stricture or leak was achieved in all patients. Three had recurrence of the anastomotic stricture on 3-month flexible sigmoidoscopy follow-up after the initial stent was removed. Two of these patients had a stricture that was technically too difficult to place another stent. Stent migration was noted in 2 patients, one at day 3 and the other at day 14 after stent placement that required a larger 23 mm stent to be placed. Conclusions. The use of SEMS in the management of colorectal anastomotic leaks or strictures is feasible and is associated with high technical and clinical success rate.

  2. A Social Potential Fields Approach for Self-Deployment and Self-Healing in Hierarchical Mobile Wireless Sensor Networks.

    Science.gov (United States)

    González-Parada, Eva; Cano-García, Jose; Aguilera, Francisco; Sandoval, Francisco; Urdiales, Cristina

    2017-01-09

    Autonomous mobile nodes in mobile wireless sensor networks (MWSN) allow self-deployment and self-healing. In both cases, the goals are: (i) to achieve adequate coverage; and (ii) to extend network life. In dynamic environments, nodes may use reactive algorithms so that each node locally decides when and where to move. This paper presents a behavior-based deployment and self-healing algorithm based on the social potential fields algorithm. In the proposed algorithm, nodes are attached to low cost robots to autonomously navigate in the coverage area. The proposed algorithm has been tested in environments with and without obstacles. Our study also analyzes the differences between non-hierarchical and hierarchical routing configurations in terms of network life and coverage.

  3. Palliative radiotherapy in addition to self-expanding metal stent for improving dysphagia and survival in advanced oesophageal cancer (ROCS: Radiotherapy after Oesophageal Cancer Stenting): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Adamson, Douglas; Blazeby, Jane; Nelson, Annmarie; Hurt, Chris; Nixon, Lisette; Fitzgibbon, Jim; Crosby, Tom; Staffurth, John; Evans, Mim; Kelly, Noreen Hopewell; Cohen, David; Griffiths, Gareth; Byrne, Anthony

    2014-10-22

    The single most distressing symptom for patients with advanced esophageal cancer is dysphagia. Amongst the more effective treatments for relief of dysphagia is insertion of a self-expanding metal stent (SEMS). It is possible that the addition of a palliative dose of external beam radiotherapy may prolong the relief of dysphagia and provide additional survival benefit. The ROCS trial will assess the effect of adding palliative radiotherapy after esophageal stent insertion. The study is a randomized multicenter phase III trial, with an internal pilot phase, comparing stent alone versus stent plus palliative radiotherapy in patients with incurable esophageal cancer. Eligible participants are those with advanced esophageal cancer who are in need of stent insertion for primary management of dysphagia. Radiotherapy will be administered as 20 Gray (Gy) in five fractions over one week or 30 Gy in 10 fractions over two weeks, within four weeks of stent insertion. The internal pilot will assess rates and methods of recruitment; pre-agreed criteria will determine progression to the main trial. In total, 496 patients will be randomized in a 1:1 ratio with follow up until death. The primary outcome is time to progression of patient-reported dysphagia. Secondary outcomes include survival, toxicity, health resource utilization, and quality of life. An embedded qualitative study will explore the feasibility of patient recruitment by examining patients' motivations for involvement and their experiences of consent and recruitment, including reasons for not consenting. It will also explore patients' experiences of each trial arm. The ROCS study will be a challenging trial studying palliation in patients with a poor prognosis. The internal pilot design will optimize methods for recruitment and data collection to ensure that the main trial is completed on time. As a pragmatic trial, study strengths include collection of all follow-up data in the usual place of care, and a focus on

  4. Optimization of cardiovascular stent against restenosis: factorial design-based statistical analysis of polymer coating conditions.

    Directory of Open Access Journals (Sweden)

    Gayathri Acharya

    Full Text Available The objective of this study was to optimize the physicodynamic conditions of polymeric system as a coating substrate for drug eluting stents against restenosis. As Nitric Oxide (NO has multifunctional activities, such as regulating blood flow and pressure, and influencing thrombus formation, a continuous and spatiotemporal delivery of NO loaded in the polymer based nanoparticles could be a viable option to reduce and prevent restenosis. To identify the most suitable carrier for S-Nitrosoglutathione (GSNO, a NO prodrug, stents were coated with various polymers, such as poly (lactic-co-glycolic acid (PLGA, polyethylene glycol (PEG and polycaprolactone (PCL, using solvent evaporation technique. Full factorial design was used to evaluate the effects of the formulation variables in polymer-based stent coatings on the GSNO release rate and weight loss rate. The least square regression model was used for data analysis in the optimization process. The polymer-coated stents were further assessed with Differential scanning calorimetry (DSC, Fourier transform infrared spectroscopy analysis (FTIR, Scanning electron microscopy (SEM images and platelet adhesion studies. Stents coated with PCL matrix displayed more sustained and controlled drug release profiles than those coated with PLGA and PEG. Stents coated with PCL matrix showed the least platelet adhesion rate. Subsequently, stents coated with PCL matrix were subjected to the further optimization processes for improvement of surface morphology and enhancement of the drug release duration. The results of this study demonstrated that PCL matrix containing GSNO is a promising system for stent surface coating against restenosis.

  5. Assessment of safety and efficacy of an indigenous self-expandable fully covered esophageal metal stent for palliation of esophageal cancer.

    Science.gov (United States)

    Padhan, R K; Nongthombam, S K; Venuthurimilli, A; Dhingra, R; Sahni, P; Garg, P K

    2016-01-01

    Patients with unresectable esophageal cancer require palliation for dysphagia. Placement of a self-expandable metal stent (SEMS) is the procedure of choice for palliation of dysphagia. To evaluate the safety and efficacy of an indigenous fully-covered SEMS in patients with esophageal cancer. Eligible patients with unresectable esophageal cancer requiring palliation for dysphagia were included in the study. An indigenous fully covered SEMS of appropriate length was placed under endoscopic and fluoroscopic guidance. Outcome measures assessed were adverse events and improvement in dysphagia. Twenty one patients (mean age 57.71±13.14 years; 17 males) were included. After stenting, dysphagia score decreased from 3.2+0.4 to 0.35+0.74 at 4 weeks. Adverse events included retrosternal pain, respiratory distress and aspiration pneumonia in 12, 2 and 1 patients respectively. Five patients required repeat stenting due to stent migration in 4 (following radiotherapy in 3) and tumour ingrowth in 1. There was primary stent malfunction in one patient. The median survival of patients was 140 (76-199) days, which was higher in those who received radiotherapy. The stent was reasonably safe and effective to relieve dysphagia due to unresectable esophageal cancer.

  6. Biodegradable stents for the treatment of refractory or recurrent benign esophageal stenosis.

    Science.gov (United States)

    Imaz-Iglesia, Iñaki; García-Pérez, Sonia; Nachtnebel, Anna; Martín-Águeda, Belén; Sánchez-Piedra, Carlos; Karadayi, Bilgehan; Demirbaş, Ali Rıza

    2016-06-01

    Esophageal stents are used for the treatment of refractory and recurrent dyphagias. In 2007, esophageal biodegradable stents (EBS) were authorised as an alternative to existing metal and plastic stents in Europe. The advantages claimed for EBS are fewer complications concerning tissue ingrowth, stent migration and stent removal. We performed a systematic review to evaluate the efficacy and safety of EBS compared to fully-covered self-expanding metal stents, self-expanding plastic stents, and esophageal dilation for the treatment of refractory or recurrent benign esophageal stenosis. Three comparative studies (one randomized controlled trial and two cohort studies) were assessed. The studies used different inclusion criteria, had a very small (sample) size and the quality of the evidence was very low. Expert commentary: The current evidence is insufficient to determine the relative efficacy or safety of esophageal biodegradable stents. The results of this systematic review should be updated once new evidence is available.

  7. Retrieval of a self-expanding metal stent after migration and incorporation in the omental bursa, using a gastroscopic-transgastric laparoscopic rendezvous technique.

    Science.gov (United States)

    Patrzyk, Maciej; Dierzek, Przemyslaw; Glitsch, Anne; Paul, Hartmut; Heidecke, Claus-Dieter

    2015-01-01

    Endoscopic drainage is a widely used treatment for pancreatic pseudocysts. Drainage-related complications may be related directly to the procedure or may occur later as stents migrate or erode into adjacent structures. Migration of a self-expanding metal stent into peritoneal cavity and incorporation in the omental bursa is rare. When endoscopic retrieval fails a combined laparoscopic-endoscopic (rendezvous technique) approach offers an alternative to open surgery. We report a case of successful gastroscopic-transgastric laparoscopic removal of a stent that was dislocated into the omental bursa after a ½ year observation period.

  8. Endovascular treatment of acutely ruptured, wide-necked anterior communicating artery aneurysms using the Enterprise stent.

    Science.gov (United States)

    Huang, Qing-Hai; Wu, Yong-Fa; Shen, Jie; Hong, Bo; Yang, Peng-Fei; Xu, Yi; Zhao, Wen-Yuan; Liu, Jian-Min

    2013-02-01

    The treatment of anterior communicating artery (AcomA) wide-necked aneurysms with the Enterprise stent (Codman, Miami Lakes, FL, USA) has not been commonly described, due to the complexity of the vascular anatomy and the small vessels of the AcomA complex. To evaluate the feasibility, effectiveness and safety of Enterprise stent placement in AcomA aneurysms, we performed this retrospective study. Between November 2008 and December 2010, 27 wide-necked AcomA ruptured aneurysms were treated within 72 hours of ictus with the Enterprise stent. Data collected and analyzed were: demographic data, morphologic features of the aneurysm, treatment results and follow-up results. Twenty-nine Enterprise stents were successfully deployed in all 27 aneurysms, including Y-configuration stent deployment in two patients. The initial embolization degrees were Raymond class I in 20 patients, class II in five and class III in the other two. The angiographic follow-up of 21 patients (mean, 8.4 months) showed that all aneurysms remained stable or improved; there was no in-stent stenosis, recurrence or retreatment. The clinical follow-up of 26 patients (mean, 12.6 months) showed that 23 patients displayed no symptoms and no or mild disability; three patients remained with severe or moderately severe disability. The Enterprise stent is feasible and safe for endovascular embolization of wide-necked AcomA ruptured aneurysms. Further follow up is needed to assess the long-term efficacy of Enterprise stent placement in AcomA. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Renal PTA stenting

    International Nuclear Information System (INIS)

    Tsetis, D.

    2012-01-01

    Full text: Renal artery stenosis (RAS) is a common condition that may lead to hypertension, progressive renal dysfunction and cardiovascular morbidity. Catheter-based therapy for symptomatic, haemodynamically significant, RAS has become the preferred method of revascularization. Balloon angioplasty has been the traditional treatment of choice for fibromuscular dysplasia, however stents are increasingly used for the treatment of atheromatous lesions; in many cases-such as in ostial lesions-, direct stenting is strongly indicated. Despite the increased use of endovascular therapy for renal artery stenosis, there is still controversy regarding the optimal management and the net benefit of this treatment. Several randomized trials of balloon angioplasty or stenting for renal artery stenosis compared with medical therapy alone have been conducted, however these could not show definite advantage of endovascular therapy. Problems encountered with those trials include enrollment of small number of patients, frequent crossover from medical to interventional therapy compromising the intention-to-treat results, or selection of patients that are not expected to show clear benefit. The Angioplasty and Stenting for Renal Artery Lesions (ASTRAL) is the most important of these trials; however, it,s study design was faulty and therefore did not provide conclusive evidence to answer the question of whether angioplasty and stenting or medical therapy is the best treatment for haemodynamically significant RAS. All expectations are now focused on the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial which was designed to answer the same question, and its methodologies took into consideration the weaknesses of the ASTRAL trial. Regarding stent device itself, it seems that the optimal design is probably a stainless steel, laser cut, open-cells stent mounted on a rapid exchange delivery balloon catheter compatible with 0.014-in and 0.018-in guidewire. As a future

  10. Clinical benefits and oncologic equivalence of self-expandable metallic stent insertion for right-sided malignant colonic obstruction.

    Science.gov (United States)

    Ji, Woong Bae; Kwak, Jung Myun; Kang, Dong Woo; Kwak, Han Deok; Um, Jun Won; Lee, Sun-Il; Min, Byung-Wook; Sung, Nak Song; Kim, Jin; Kim, Seon Hahn

    2017-01-01

    The efficacy of stenting for right-sided malignant colonic obstruction is unknown. This study aimed to evaluate the safety, feasibility, and clinical benefits of self-expandable metallic stent insertion for right-sided malignant colonic obstruction. Clinical data from patients who underwent right hemicolectomy for right colon cancer from January 2006 to July 2014 at three Korea University hospitals were retrospectively reviewed. A total of 39 patients who developed malignant obstruction in the right-sided colon were identified, and their data were analyzed. Stent insertion was attempted in 16 patients, and initial technical success was achieved in 14 patients (87.5 %). No stent-related immediate complications were reported. Complete relief from obstruction was achieved in all 14 patients. Twenty-five patients, including two patients who failed stenting, underwent emergency surgery. In the stent group, 93 % (13/14) of patients underwent elective laparoscopic surgery, and only one surgery was converted to an open procedure. All patients in the emergency group underwent emergency surgery within 24 h of admission. In the emergency group, only 12 % (3/25) of patients underwent laparoscopic surgery, with one surgery converted to an open procedure. All patients in both groups underwent either laparoscopy-assisted or open right/extended right hemicolectomy with primary anastomoses as the first operation. The operative times, retrieved lymph nodes, and pathologic stage did not differ between the two groups. Postoperative hospital stay (9.4 ± 3.4 days in the stent group vs. 12.4 ± 5.9 in the emergency group, p = 0.089) and time to resume oral food intake (3.2 ± 2.1 days in the stent group vs. 5.7 ± 3.4 in the emergency group, p = 0.019) were shorter in the stent group. And there were no significant differences in disease-free survival and overall survival between the two groups. Stent insertion appears to be safe and feasible in patients with right

  11. Air cholangiography in endoscopic bilateral stent-in-stent placement of metallic stents for malignant hilar biliary obstruction.

    Science.gov (United States)

    Lee, Jae Min; Lee, Sang Hyub; Jang, Dong Kee; Chung, Kwang Hyun; Park, Jin Myung; Paik, Woo Hyun; Lee, Jun Kyu; Ryu, Ji Kon; Kim, Yong-Tae

    2016-03-01

    Although endoscopic bilateral stent-in-stent (SIS) placement of self-expandable metallic stents (SEMS) is one of the major palliative treatments for unresectable malignant hilar biliary obstruction, post-endoscopic retrograde cholangiopancreatography (ERCP) cholangitis can occur frequently due to inadequate drainage, especially after contrast injection into the biliary tree. The aim of this study is to evaluate the efficacy and safety of air cholangiography-assisted stenting. This study included 47 patients with malignant hilar biliary obstruction who underwent endoscopic bilateral SEMS placement using the SIS technique. They were divided into two groups, air (n = 23) or iodine contrast (n = 24) cholangiography. We retrospectively compared comprehensive clinical and laboratory data of both groups. There were no significant differences found between the two groups with respect to technical success (87% versus 87.5%, air versus contrast group, respectively), functional success (95% versus 95.2%), 30-day mortality (8.3% versus 8.7%) and stent patency. Post-ERCP adverse events occurred in 5 (21.7%) of the patients in the air group and 8 (33.3%) of the patients in the contrast group. Among these, the rate of cholangitis was significantly lower in the air group (4.8% versus 29.2%, p = 0.048). In multivariate analysis, air cholangiography, technical success and a shorter procedure time were significantly associated with a lower incidence of post-ERCP cholangitis. Air cholangiography-assisted stenting can be a safe and effective method for endoscopic bilateral SIS placement of SEMS in patients with malignant hilar biliary obstruction.

  12. Stent placement for esophageal strictures : an update

    NARCIS (Netherlands)

    Hirdes, Meike Madeleine Catharine; Vleggaar, Frank Paul; Siersema, Peter Derk

    The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief

  13. Design and analysis of a deployable truss for the large modular mesh antenna

    Science.gov (United States)

    Meguro, Akira

    This paper describes the design and deployment analysis for large deployable modular mesh antennas. Key design criteria are deployability, and the driving force and latching moment requirements. Reaction forces and moments due to mesh and cable network seriously influence the driving force. These forces and moments can be precisely estimated by means of analyzing the cable network using Cable Structure Analyzer (CASA). Deployment analysis is carried out using Dynamic Analysis and Design System (DADS). The influence of alignment errors on the driving reaction force can be eliminated by replacing the joint element with a spring element. The joint slop is also modeled using a discontinuous spring elements. Their design approach for three types of deployable modules and the deployment characterstics of three Bread-Board Models based on those designs are also presented. In order to study gravity effects on the deployment characteristics and the effects of the gravity compensation method, ground deployment analysis is carried out. A planned deployment test that will use aircraft parabolic flight to simulate a micro-gravity environment is also described.

  14. Reverse waffle cone technique in management of stent dislodgement into intracranial aneurysms.

    Science.gov (United States)

    Luo, Chao-Bao; Lai, Yen-Jun; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2013-09-01

    Stent-assisted coil embolization (SACE) is a common method to manage intracranial wide-neck aneurysm. Using this technique, a stent must be successfully deployed into the parent artery to cross the aneurysm neck. We describe the reverse waffle cone technique in management of intra-procedural stent dislodgement during SACE of internal carotid artery (ICA) wide-neck aneurysms. Two patients with unruptured wide-neck ICA aneurysms underwent SACE. Intra-procedural forward stent migration occurred during catheterization with proximal stent dislodgement and migration into the aneurysm sac. Navigation of a second stent to bridge the aneurysm neck failed in one patient because the second stent was impeded by the dislodged stent. Using the reverse waffle cone technique, a microcatheter was navigated into the aneurysm sacs. Coils were safely detached into each aneurysm sac without any device assistance. The two wide-neck aneurysms were successfully treated with preservation of flow to the internal carotid arteries. The complication of intra-procedural distal stent migration and dislodgement, with proximal stent prolapse into an aneurysm sac, may not result in a failure to coil the aneurysm. The reverse waffle cone technique provides an effective treatment in the management of this complication. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Intravascular ultrasound evaluation of a pseudolesion created by stent placement in the right artery.

    Science.gov (United States)

    Zientek, D M; Rodgers, G P

    1999-10-01

    The creation of a pseudolesion after guidewire placement in tortuous arterial segments is a well recognized phenomenon. Intravascular ultrasound has been useful in assessing deployment of intracoronary stents and equivocal angiographic findings. We present a case in which a pseudolesion was not observed until after placement of an intracoronary stent. Intravascular ultrasound demonstrated no dissection or significant lesion; however, there was focal calcification just distal to the stent providing a substrate for the distorted vessel architecture. The lesion resolved with removal of the guidewire.

  16. Customized Hinged Covered Metallic Stents for the Treatment of Benign Main Bronchial Stenosis.

    Science.gov (United States)

    Han, Xinwei; Al-Tariq, Quazi; Zhao, Yanle; Li, Lei; Cheng, Zhe; Wang, Huaqi; Liu, Chao; Jiao, Dechao; Wu, Gang

    2017-08-01

    To address the limitations of silicone stents, we designed a hinged self-expandable covered metallic stent. The aim of this study was to evaluate the safety and efficacy of the customized stents in clinical applications. This was a retrospective analysis. Under conscious sedation and local anesthesia, the stents were implanted or removed by interventional radiologists, with fluoroscopic guidance. Of 24 patients with benign main bronchial stenosis, stents were successfully placed in 21 (87.5%). The low-pressure balloon before dilation failed in 1 case (4.17%) of left main bronchial cicatricial stenosis. In 2 other cases (8.33%), stent placement was abandoned. Stents were successfully removed between 29 and 103 days after the procedure. After stent removal, the follow-up lasted for at least 12 months. Restenosis occurred only in 1 case (4.55%) owing to bronchial collapse 3 days after stent removal. Dyspnea occurred in another case (4.55%) at 2 months after retrieval; recurrence was confirmed using bronchoscopy, leading to a left pneumonectomy. The described procedure is safe and easy to be performed and avoids the use of intubation, bronchoscopy, and general anesthesia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Vascular stents: Coupling full 3-D with reduced-order structural models

    International Nuclear Information System (INIS)

    Avdeev, I; Shams, M

    2010-01-01

    Self-expanding nitinol stents are used to treat peripheral arterial disease. The peripheral arteries are subjected to a combination of mechanical forces such as compression, torsion, bending, and contraction. Most commercially available peripheral self-expanding stents are composed of a series of sub-millimeter V-shaped struts, which are laser-cut from a nitinol tube and surface-treated for better fatigue performance. The numerical stent models must accurately predict location and distribution of local stresses and strains caused by large arterial deformations. Full 3-D finite element non-linear analysis of an entire stent is computationally expensive to the point of being prohibitive, especially for longer stents. Reduced-order models based on beam or shell elements are fairly accurate in capturing global deformations, but are not very helpful in predicting stent failure. We propose a mixed approach that combines the full 3-D model and reduced-order models. Several global-local, full 3-D/reduced-order finite element models of a peripheral self-expanding stent were validated and compared with experimental data. The kinematic constraint method used to couple various elements together was found to be very efficient and easily applicable to commercial FEA codes. The proposed mixed models can be used to accurately predict stent failure based on realistic (patient-specific), non-linear kinematic behavior of peripheral arteries.

  18. A Social Potential Fields Approach for Self-Deployment and Self-Healing in Hierarchical Mobile Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Eva González-Parada

    2017-01-01

    Full Text Available Autonomous mobile nodes in mobile wireless sensor networks (MWSN allow self-deployment and self-healing. In both cases, the goals are: (i to achieve adequate coverage; and (ii to extend network life. In dynamic environments, nodes may use reactive algorithms so that each node locally decides when and where to move. This paper presents a behavior-based deployment and self-healing algorithm based on the social potential fields algorithm. In the proposed algorithm, nodes are attached to low cost robots to autonomously navigate in the coverage area. The proposed algorithm has been tested in environments with and without obstacles. Our study also analyzes the differences between non-hierarchical and hierarchical routing configurations in terms of network life and coverage.

  19. Efficacy of Endoscopic Over 3-branched Partial Stent-in-Stent Drainage Using Self-expandable Metallic Stents in Patients With Unresectable Hilar Biliary Carcinoma.

    Science.gov (United States)

    Uchida, Daisuke; Kato, Hironari; Muro, Shinichiro; Noma, Yasuhiro; Yamamoto, Naoki; Horiguchi, Shigeru; Harada, Ryo; Tsutsumi, Koichiro; Kawamoto, Hirofumi; Okada, Hiroyuki; Yamamoto, Kazuhide

    2015-07-01

    The treatment of biliary stricture is crucially important for continuing stable chemotherapy for unresectable biliary carcinoma; however, there is no consensus regarding the use of hilar biliary drainage. In this study, we examined the efficacy of endoscopic over 3-branched biliary drainage using self-expandable metallic stents (SEMSs) in patients with unresectable malignant hilar biliary stricture (HBS). A total of 77 patients with unresectable HBS treated with a SEMS and chemotherapy were retrospectively reviewed. There were 59 patients with cholangiocarcinoma and 18 patients with gallbladder carcinoma. The patients were divided into 2 groups (4- or 3-branched group and 2- or 1-branched group) and compared with respect to the duration of stent patency and overall survival. A comparison of the patients' baseline characteristics showed no significant differences between the 4- or 3-branched group and the 2- or 1-branched group. Neither the duration of patency nor survival time exhibited significant differences between the 2 groups, although, among the patients achieving disease control , the duration of patency period and survival time of the 4- or 3-branched group were significantly higher than those observed in the 2- or 1-branched group (P=0.0231 and 0.0466). The use of endoscopic over 3-branched biliary drainage with a SEMS may improve the duration of patency in patients with HBS.

  20. Long-term safety and outcome of a temporary self-expanding metallic stent for achalasia: a prospective study with a 13-year single-center experience

    International Nuclear Information System (INIS)

    Zhao, Jun-Gong; Li, Yong-Dong; Li, Ming-Hua; Shang, Ke-Zhong; Cheng, Ying-Sheng; Chen, Ni-Wei; Chen, Wei-Xiong

    2009-01-01

    To prospectively evaluate the long-term clinical safety and efficacy of a newly designed self-expanding metallic stent (SEMS) in the treatment of patients with achalasia. Seventy-five patients with achalasia were treated with a temporary SEMS with a 30-mm diameter. The SEMSs were placed under fluoroscopic guidance and removed by gastroscopy 4-5 days after stent placement. Follow-up data focused on dysphagia score, technique and clinical success, clinical remissions and failures, and complications and was performed at 6 months, 1 year, and within 3 to 5 years, 5 to 8 years, 8 to 10 years, and >10 years postoperatively. Stent placement was technically successful in all patients. Complications included stent migration (n=4, 5.33%), chest pain (n=28, 38.7%), reflux (n=15, 20%), and bleeding (n=9, 12%). No perforation or 30-day mortality occurred. Clinical success was achieved in all patients 1 month after stent removal. The overall remission rates at 6 months, 1, 1-3, 3-5, 5-8, 8-10, and >10 year follow-up periods were 100%, 96%, 93.9%, 90.9%, 100%, 100%, and 83.3%, respectively. Stent treatment failed in six patients, and the overall remission rate in our series was 92%. The median and mean primary patencies were 2.8 ± 0.28 years (95% CI: 2.25-3.35) and 4.28 ± 0.40 years (95% CI: 3.51-5.05), respectively. The use of temporary SEMSs with 30-mm diameter proved to be a safe and effective approach for managing achalasia with a long-term satisfactory clinical remission rate. (orig.)