WorldWideScience

Sample records for selectively improve sensitivity

  1. A novel method of selective removal of human DNA improves PCR sensitivity for detection of Salmonella Typhi in blood samples.

    Science.gov (United States)

    Zhou, Liqing; Pollard, Andrew J

    2012-07-27

    Enteric fever is a major public health problem, causing an estimated 21million new cases and 216,000 or more deaths every year. Current diagnosis of the disease is inadequate. Blood culture only identifies 45 to 70% of the cases and is time-consuming. Serological tests have very low sensitivity and specificity. Clinical samples obtained for diagnosis of enteric fever in the field generally have blood, so that even PCR-based methods, widely used for detection of other infectious diseases, are not a straightforward option in typhoid diagnosis. We developed a novel method to enrich target bacterial DNA by selective removal of human DNA from blood samples, enhancing the sensitivity of PCR tests. This method offers the possibility of improving PCR assays directly using clinical specimens for diagnosis of this globally important infectious disease. Blood samples were mixed with ox bile for selective lysis of human blood cells and the released human DNA was then digested with addition of bile resistant micrococcal nuclease. The intact Salmonella Typhi bacteria were collected from the specimen by centrifugation and the DNA extracted with QIAamp DNA mini kit. The presence of Salmonella Typhi bacteria in blood samples was detected by PCR with the fliC-d gene of Salmonella Typhi as the target. Micrococcal nuclease retained activity against human blood DNA in the presence of up to 9% ox bile. Background human DNA was dramatically removed from blood samples through the use of ox bile lysis and micrococcal nuclease for removal of mammalian DNA. Consequently target Salmonella Typhi DNA was enriched in DNA preparations and the PCR sensitivity for detection of Salmonella Typhi in spiked blood samples was enhanced by 1,000 fold. Use of a combination of selective ox-bile blood cell lysis and removal of human DNA with micrococcal nuclease significantly improves PCR sensitivity and offers a better option for improved typhoid PCR assays directly using clinical specimens in diagnosis of

  2. Wavenumber selection based analysis in Raman spectroscopy improves skin cancer diagnostic specificity at high sensitivity levels (Conference Presentation)

    Science.gov (United States)

    Zhao, Jianhua; Zeng, Haishan; Kalia, Sunil; Lui, Harvey

    2017-02-01

    Background: Raman spectroscopy is a non-invasive optical technique which can measure molecular vibrational modes within tissue. A large-scale clinical study (n = 518) has demonstrated that real-time Raman spectroscopy could distinguish malignant from benign skin lesions with good diagnostic accuracy; this was validated by a follow-up independent study (n = 127). Objective: Most of the previous diagnostic algorithms have typically been based on analyzing the full band of the Raman spectra, either in the fingerprint or high wavenumber regions. Our objective in this presentation is to explore wavenumber selection based analysis in Raman spectroscopy for skin cancer diagnosis. Methods: A wavenumber selection algorithm was implemented using variably-sized wavenumber windows, which were determined by the correlation coefficient between wavenumbers. Wavenumber windows were chosen based on accumulated frequency from leave-one-out cross-validated stepwise regression or least and shrinkage selection operator (LASSO). The diagnostic algorithms were then generated from the selected wavenumber windows using multivariate statistical analyses, including principal component and general discriminant analysis (PC-GDA) and partial least squares (PLS). A total cohort of 645 confirmed lesions from 573 patients encompassing skin cancers, precancers and benign skin lesions were included. Lesion measurements were divided into training cohort (n = 518) and testing cohort (n = 127) according to the measurement time. Result: The area under the receiver operating characteristic curve (ROC) improved from 0.861-0.891 to 0.891-0.911 and the diagnostic specificity for sensitivity levels of 0.99-0.90 increased respectively from 0.17-0.65 to 0.20-0.75 by selecting specific wavenumber windows for analysis. Conclusion: Wavenumber selection based analysis in Raman spectroscopy improves skin cancer diagnostic specificity at high sensitivity levels.

  3. Improving the selectivity and sensitivity for quantifying 8-α-hydroxy-mutilin in rabbit tissues by using basic mobile phases and negative ionization.

    Science.gov (United States)

    Tan, Aimin; Gu, Guifen; Gui, Xuan; Wu, Yanxin; Bolger, Gordon; Licollari, Albert; Fanaras, John C

    2018-01-01

    Previously reported LC-MS methods for quantifying 8-α-hydroxy-mutilin (a marker residue of tiamulin) in tissues all used a pseudo MRM transition (from protonated molecular ion to protonated molecular ion, m/z 337→337) due to difficulties in finding a product ion, leading to suboptimal selectivity and sensitivity for detection. By using electrospray negative ionization in a basic medium, we, for the first time, found a highly selective and sensitive true MRM transition for 8-α-hydroxy-mutilin, m/z 335→179. With this newly found MRM transition and the use of pleuromutilin as the internal standard, a very sensitive, selective, and robust LC-MS/MS method has been developed and validated for quantifying 8-α-hydroxy-mutilin in rabbit tissues (muscle, liver, kidney, and fat). In comparison with the previously published methods, the selectivity and sensitivity were significantly improved. For the concentration range validated (0.2-10ppm or 0.2-10μg/g), the within-run and between-run accuracies (% bias) ranged from -5.0 to 3.1 and -4.9 to 3.0, respectively. The% CV ranged from 2.2 to 6.6 and 4.7 to 8.3 for within-run and between-run precisions, respectively. The validated method was successfully used to support two GLP tissue residue depletion studies in rabbits. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. High-field modulated ion-selective field-effect-transistor (FET) sensors with sensitivity higher than the ideal Nernst sensitivity.

    Science.gov (United States)

    Chen, Yi-Ting; Sarangadharan, Indu; Sukesan, Revathi; Hseih, Ching-Yen; Lee, Geng-Yen; Chyi, Jen-Inn; Wang, Yu-Lin

    2018-05-29

    Lead ion selective membrane (Pb-ISM) coated AlGaN/GaN high electron mobility transistors (HEMT) was used to demonstrate a whole new methodology for ion-selective FET sensors, which can create ultra-high sensitivity (-36 mV/log [Pb 2+ ]) surpassing the limit of ideal sensitivity (-29.58 mV/log [Pb 2+ ]) in a typical Nernst equation for lead ion. The largely improved sensitivity has tremendously reduced the detection limit (10 -10  M) for several orders of magnitude of lead ion concentration compared to typical ion-selective electrode (ISE) (10 -7  M). The high sensitivity was obtained by creating a strong filed between the gate electrode and the HEMT channel. Systematical investigation was done by measuring different design of the sensor and gate bias, indicating ultra-high sensitivity and ultra-low detection limit obtained only in sufficiently strong field. Theoretical study in the sensitivity consistently agrees with the experimental finding and predicts the maximum and minimum sensitivity. The detection limit of our sensor is comparable to that of Inductively-Coupled-Plasma Mass Spectrum (ICP-MS), which also has detection limit near 10 -10  M.

  5. Solid polymeric electrolyte based dye-sensitized solar cell with improved stability

    Science.gov (United States)

    Prasad, Narottam; Kumar, Manish; Patel, K. R.; Roy, M. S.

    2018-05-01

    The impact of polymeric electrolyte was investigated over the performance of dye-sensitized solar cell made with Rose Bengal as sensitizer. Further, the selective influence of TiCl4 treatment and pre-sensitizer deoxycholic acid on nc-TiO2 photoanode was determined in terms of improvement in conversion efficiency of the cell. It is found that the effect of TiCl4 treatment was comparatively more than pre-sensitization with de-oxy cholic acid towards improving the efficiency of the cell. The conversion efficiency on TiCl4 treatment was 0.2% whereas on pre-sensitization with deoxy chollic acid it was 0.1%. The combined effect of both TiCl4 treatment & pre-sensitization with deoxycholic acid leads conversion efficiency to 0.33%.

  6. Improving Blast Resistance of a Thermo-Sensitive Genic Male Sterile Rice Line GD-8S by Molecular Marker-Assisted Selection

    Directory of Open Access Journals (Sweden)

    Wu-ge LIU

    2008-09-01

    Full Text Available The broad-spectrum blast resistance gene Pi-1, from donor line BL122, was introduced into a thermo-sensitive genic male sterile rice line GD-8S, which possessed good grain quality but high susceptibility to rice blast, by using backcross breeding and molecular marker-assisted selection. Five elite improved male sterile lines, RGD8S-1, RGD8S-2, RGD8S-3, RGD8S-4 and RGD8S-5, were selected based on the results of molecular marker analysis, spikelet sterility, recovery rate of genetic background and agronomic traits. Thirty-three representative blast isolates collected from Guangdong Province, China were used to inoculate the improved lines and the original line GD-8S artificially. The resistance frequencies of the improved lines ranged from 76.47% to 100%, much higher than that of the original line GD-8S (9.09%. On the agronomic characters, there were no significant differences between the improved lines and GD-8S except for flag leaf length and panicle number per plant. The improved lines could be used for breeding hybrid rice with high blast resistance.

  7. Dualism of Sensitivity and Selectivity of Porphyrin Dimers in Electroanalysis.

    Science.gov (United States)

    Lisak, Grzegorz; Tamaki, Takashi; Ogawa, Takuji

    2017-04-04

    This work uncovers the application of porphyrin dimers for the use in electroanalysis, such as potentiometric determination of ions. It also puts in question a current perception of an occurrence of the super-Nernstian response, as a result of the possible dimerization of single porphyrins within an ion-selective membrane. To study that, four various porphyrin dimers were used as ionophores, namely, freebase-freebase, Zn-Zn, Zn-freebase, and freebase-Zn. Since the Zn-freebase and freebase-Zn porphyrin dimers carried both anion- and cation-sensitive porphyrin units, their application in ISEs was utilized in both anion- and cation-sensitive sensors. With respect to the lipophilic salt added, both porphyrins dimers were found anion- and cation-sensitive. This allowed using a single molecule as novel type of versatile ionophore (anion- and cation-selective), simply by varying the membrane composition. All anion-sensitive sensors were perchlorate-sensitive, while the cation-selective sensors were silver-sensitive. The selectivity of the sensors depended primarily on the porphyrin dimers in the ion-selective membrane. Furthermore, the selectivity of cation-sensitive dimer based sensors was found significantly superior to the ones measured for the single porphyrin unit based sensors (precursors of the porphyrin dimers). Thus, the dimerization of single porphyrins may actually be a factor to increase or modulate porphyrin selectivity. Moreover, in the case of cation-sensitive sensors, the selectivity vastly depended on the order of porphyrin units in the dimer. This opens a new approach of regulating and adjusting sensitivity and selectivity of the sensor through the application of complex porphyrin systems with more than one porphyrin units with mix sensitive porphyrins.

  8. Body size, swimming speed, or thermal sensitivity? Predator-imposed selection on amphibian larvae.

    Science.gov (United States)

    Gvoždík, Lumír; Smolinský, Radovan

    2015-11-02

    Many animals rely on their escape performance during predator encounters. Because of its dependence on body size and temperature, escape velocity is fully characterized by three measures, absolute value, size-corrected value, and its response to temperature (thermal sensitivity). The primary target of the selection imposed by predators is poorly understood. We examined predator (dragonfly larva)-imposed selection on prey (newt larvae) body size and characteristics of escape velocity using replicated and controlled predation experiments under seminatural conditions. Specifically, because these species experience a wide range of temperatures throughout their larval phases, we predict that larvae achieving high swimming velocities across temperatures will have a selective advantage over more thermally sensitive individuals. Nonzero selection differentials indicated that predators selected for prey body size and both absolute and size-corrected maximum swimming velocity. Comparison of selection differentials with control confirmed selection only on body size, i.e., dragonfly larvae preferably preyed on small newt larvae. Maximum swimming velocity and its thermal sensitivity showed low group repeatability, which contributed to non-detectable selection on both characteristics of escape performance. In the newt-dragonfly larvae interaction, body size plays a more important role than maximum values and thermal sensitivity of swimming velocity during predator escape. This corroborates the general importance of body size in predator-prey interactions. The absence of an appropriate control in predation experiments may lead to potentially misleading conclusions about the primary target of predator-imposed selection. Insights from predation experiments contribute to our understanding of the link between performance and fitness, and further improve mechanistic models of predator-prey interactions and food web dynamics.

  9. Sensitivity analysis for improving nanomechanical photonic transducers biosensors

    International Nuclear Information System (INIS)

    Fariña, D; Álvarez, M; Márquez, S; Lechuga, L M; Dominguez, C

    2015-01-01

    The achievement of high sensitivity and highly integrated transducers is one of the main challenges in the development of high-throughput biosensors. The aim of this study is to improve the final sensitivity of an opto-mechanical device to be used as a reliable biosensor. We report the analysis of the mechanical and optical properties of optical waveguide microcantilever transducers, and their dependency on device design and dimensions. The selected layout (geometry) based on two butt-coupled misaligned waveguides displays better sensitivities than an aligned one. With this configuration, we find that an optimal microcantilever thickness range between 150 nm and 400 nm would increase both microcantilever bending during the biorecognition process and increase optical sensitivity to 4.8   ×   10 −2  nm −1 , an order of magnitude higher than other similar opto-mechanical devices. Moreover, the analysis shows that a single mode behaviour of the propagating radiation is required to avoid modal interference that could misinterpret the readout signal. (paper)

  10. The selectively bred high alcohol sensitivity (HAS) and low alcohol sensitivity (LAS) rats differ in sensitivity to nicotine.

    Science.gov (United States)

    de Fiebre, NancyEllen C; Dawson, Ralph; de Fiebre, Christopher M

    2002-06-01

    Studies in rodents selectively bred to differ in alcohol sensitivity have suggested that nicotine and ethanol sensitivities may cosegregate during selective breeding. This suggests that ethanol and nicotine sensitivities may in part be genetically correlated. Male and female high alcohol sensitivity (HAS), control alcohol sensitivity, and low alcohol sensitivity (LAS) rats were tested for nicotine-induced alterations in locomotor activity, body temperature, and seizure activity. Plasma and brain levels of nicotine and its primary metabolite, cotinine, were measured in these animals, as was the binding of [3H]cytisine, [3H]epibatidine, and [125I]alpha-bungarotoxin in eight brain regions. Both replicate HAS lines were more sensitive to nicotine-induced locomotor activity depression than the replicate LAS lines. No consistent HAS/LAS differences were seen on other measures of nicotine sensitivity; however, females were more susceptible to nicotine-induced seizures than males. No HAS/LAS differences in nicotine or cotinine levels were seen, nor were differences seen in the binding of nicotinic ligands. Females had higher levels of plasma cotinine and brain nicotine than males but had lower brain cotinine levels than males. Sensitivity to a specific action of nicotine cosegregates during selective breeding for differential sensitivity to a specific action of ethanol. The differential sensitivity of the HAS/LAS rats is due to differences in central nervous system sensitivity and not to pharmacokinetic differences. The differential central nervous system sensitivity cannot be explained by differences in the numbers of nicotinic receptors labeled in ligand-binding experiments. The apparent genetic correlation between ethanol and nicotine sensitivities suggests that common genes modulate, in part, the actions of both ethanol and nicotine and may explain the frequent coabuse of these agents.

  11. Sensor selection of helicopter transmission systems based on physical model and sensitivity analysis

    Directory of Open Access Journals (Sweden)

    Lyu Kehong

    2014-06-01

    Full Text Available In the helicopter transmission systems, it is important to monitor and track the tooth damage evolution using lots of sensors and detection methods. This paper develops a novel approach for sensor selection based on physical model and sensitivity analysis. Firstly, a physical model of tooth damage and mesh stiffness is built. Secondly, some effective condition indicators (CIs are presented, and the optimal CIs set is selected by comparing their test statistics according to Mann–Kendall test. Afterwards, the selected CIs are used to generate a health indicator (HI through sen slop estimator. Then, the sensors are selected according to the monotonic relevance and sensitivity to the damage levels. Finally, the proposed method is verified by the simulation and experimental data. The results show that the approach can provide a guide for health monitoring of helicopter transmission systems, and it is effective to reduce the test cost and improve the system’s reliability.

  12. Evaluation of texaphyrins as tumor selective radiation sensitizers

    International Nuclear Information System (INIS)

    Qing Fan; Woodburn, Kathryn W.; Young, Stuart W.

    1997-01-01

    Texaphyrins are expanded porphyrin macrocycles that selectively localize and are retained in cancerous lesions. The function of the texaphyrin can be manipulated by the incorporation of different metal ions into the macrocycle's central cavity. Gadolinium texaphyrin (Gd-Tex) and lutetium texaphyrin (Lu-Tex) were evaluated as radiation sensitizers. Radiation sensitization studies were performed using SMT-F and EMT6 mammary tumor-bearing mice. Single and multifraction dose regimens were performed. SMT-F bearing DBA/2N mice and EMT6 bearing Balb/c mice were intravenously administered with Gd-Tex of Lu-Tex (5-40 μmol/kg) 30 minutes to 5 hours prior to radiation (10-50 Gray) for the single fraction studies. The more radioresistant EMT-6 sarcoma model was used for the multifraction studies. The tumor bearing animals were injected with Gd-Tex (5, 20, or 40 μmol/kg) to 2 hours prior radiation (1, 2, or 4 Gray), this regimen was performed for five consecutive days. Gd-Tex is paramagnetic and has a strong fluorescence signal. Tumor selectivity was determined by MRI and fluorescence spectral imaging before and up to 24 hours following the administration of Gd-Tex. Gd-Tex but not Lu-Tex, proved to be an effective radiation sensitizer. Administration of Gd-Tex (40 μmol/kg) prior to a single dose of 30 Gray radiation provided a significant improvement in survival in SMT-F-bearing DBA/2N mice as compared to animals receiving radiation alone (p = 0.0034). A significant radiation sensitization effect was also found in multiple fraction studies (five consecutive days) with Balb/C mice bearing EMT-6 neoplasma-- following 1 Gray of radiation for 5 days there was a significant difference between the 20 and 40 μmol/kg group and controls (p = 0.003, p = 0.005 respectively). MRI and fluorescence spectral imaging studies of tumor bearing animals revealed excellent contrast enhancement of the tumor which persisted up to 24 hours. Texaphyrins localize in neoplasms as visualized using MRI

  13. Selectivity, specificity, and sensitivity in the photoionization of sputtered species

    International Nuclear Information System (INIS)

    Gruen, D.M.; Calaway, W.F.; Pellin, M.J.; Young, C.E.; Spiegel, D.R.; Clayton, R.N.; Davis, A.M.; Blum, J.D.

    1990-01-01

    To deal with the problem of non- or near-resonant ionization, one needs to achieve the highest selectively for photoionization of the species of interest relative to isobarically overlapping species by choosing a specific photoionization scheme tailoring are that is could not have near-overlap with known atomic or molecular energy levels of isobaric species, and that it should lead to saturation of the resonance transitions at the lowest possible laser power levels so as to minimize two- and three-photon nonresonant photoionization processes. Experience has shown that, even when these two conditions are met as closely as possible, non- or near-resonant ionization can still occur, perhaps because of the existence of hitherto unobserved energy levels, photodissociation of sputtered molecules, or other effects. It is becoming clear that maximizing detection sensitivity for a particular species requires one to pay careful attention to the selection of an optimal photoionization scheme. It is the purpose of the present paper to illustrate this point with several examples and to help point the way to still further improvements in detection sensitivity by non- or near-resonant. ionization through detailed exploration of alternative photoionization schemes

  14. Highly Sensitive and Selective Hydrogen Gas Sensor Using the Mesoporous SnO2 Modified Layers

    Directory of Open Access Journals (Sweden)

    Niuzi Xue

    2017-10-01

    Full Text Available It is important to improve the sensitivities and selectivities of metal oxide semiconductor (MOS gas sensors when they are used to monitor the state of hydrogen in aerospace industry and electronic field. In this paper, the ordered mesoporous SnO2 (m-SnO2 powders were prepared by sol-gel method, and the morphology and structure were characterized by X-ray diffraction analysis (XRD, transmission electron microscope (TEM and Brunauer–Emmett–Teller (BET. The gas sensors were fabricated using m-SnO2 as the modified layers on the surface of commercial SnO2 (c-SnO2 by screen printing technology, and tested for gas sensing towards ethanol, benzene and hydrogen with operating temperatures ranging from 200 °C to 400 °C. Higher sensitivity was achieved by using the modified m-SnO2 layers on the c-SnO2 gas sensor, and it was found that the S(c/m2 sensor exhibited the highest response (Ra/Rg = 22.2 to 1000 ppm hydrogen at 400 °C. In this paper, the mechanism of the sensitivity and selectivity improvement of the gas sensors is also discussed.

  15. Improving the sensitivity of LISA

    International Nuclear Information System (INIS)

    Nayak, K Rajesh; Pai, A; Dhurandhar, S V; Vinet, J-Y

    2003-01-01

    It has been shown in several recent papers that the six Doppler data streams obtained from a triangular LISA configuration can be combined by appropriately delaying the data streams for cancelling the laser frequency noise. Raw laser noise is several orders of magnitude above the other noises and thus it is essential to bring it down to the level of other noises such as shot, acceleration, etc. A rigorous and systematic formalism using the powerful techniques of computational commutative algebra was developed, which generates in principle all the data combinations cancelling the laser frequency noise. The relevant data combinations form a first module of syzygies. In this paper, we use this formalism to advantage for optimizing the sensitivity of LISA by analysing the noise and signal covariance matrices. The signal covariance matrix is calculated for binaries whose frequency changes at most adiabatically and the signal is averaged over polarizations and directions. We then present the extremal SNR curves for all the data combinations in the module. They correspond to the eigenvectors of the noise and signal covariance matrices. A LISA 'network' SNR is also computed by combining the outputs of the eigenvectors. We show that substantial gains in sensitivity can be obtained by employing these strategies. The maximum SNR curve can yield an improvement up to 70% over the Michelson, mainly at high frequencies, while the improvement using the network SNR ranges from 40% to over 100%. Finally, we describe a simple toy model, in which LISA rotates in a plane. In this analysis, we estimate the improvement in the LISA sensitivity, if one switches from one data combination to another as it rotates. Here the improvement in sensitivity, if one switches optimally over three cyclic data combinations of the eigenvector, is about 55% on average over the LISA bandwidth. The corresponding SNR improvement increases to 60%, if one maximizes over the module

  16. FTIR gas analysis with improved sensitivity and selectivity for CWA and TIC detection

    Science.gov (United States)

    Phillips, Charles M.; Tan, Huwei

    2010-04-01

    This presentation describes the use of an FTIR (Fourier Transform Infrared)-based spectrometer designed to continuously monitor ambient air for the presence of chemical warfare agents (CWAs) and toxic industrial chemicals (TICs). The necessity of a reliable system capable of quickly and accurately detecting very low levels of CWAs and TICs while simultaneously retaining a negligible false alarm rate will be explored. Technological advancements in FTIR sensing have reduced noise while increasing selectivity and speed of detection. These novel analyzer design characteristics are discussed in detail and descriptions are provided which show how optical throughput, gas cell form factor, and detector response are optimized. The hardware and algorithms described here will explain why this FTIR system is very effective for the simultaneous detection and speciation of a wide variety of toxic compounds at ppb concentrations. Analytical test data will be reviewed demonstrating the system's sensitivity to and selectivity for specific CWAs and TICs; this will include recent data acquired as part of the DHS ARFCAM (Autonomous Rapid Facility Chemical Agent Monitor) project. These results include analyses of the data from live agent testing for the determination of CWA detection limits, immunity to interferences, detection times, residual noise analysis and false alarm rates. Sensing systems such as this are critical for effective chemical hazard identification which is directly relevant to the CBRNE community.

  17. An Efficient Cost-Sensitive Feature Selection Using Chaos Genetic Algorithm for Class Imbalance Problem

    Directory of Open Access Journals (Sweden)

    Jing Bian

    2016-01-01

    Full Text Available In the era of big data, feature selection is an essential process in machine learning. Although the class imbalance problem has recently attracted a great deal of attention, little effort has been undertaken to develop feature selection techniques. In addition, most applications involving feature selection focus on classification accuracy but not cost, although costs are important. To cope with imbalance problems, we developed a cost-sensitive feature selection algorithm that adds the cost-based evaluation function of a filter feature selection using a chaos genetic algorithm, referred to as CSFSG. The evaluation function considers both feature-acquiring costs (test costs and misclassification costs in the field of network security, thereby weakening the influence of many instances from the majority of classes in large-scale datasets. The CSFSG algorithm reduces the total cost of feature selection and trades off both factors. The behavior of the CSFSG algorithm is tested on a large-scale dataset of network security, using two kinds of classifiers: C4.5 and k-nearest neighbor (KNN. The results of the experimental research show that the approach is efficient and able to effectively improve classification accuracy and to decrease classification time. In addition, the results of our method are more promising than the results of other cost-sensitive feature selection algorithms.

  18. Prevalence of sensitization to 'improver' enzymes in UK supermarket bakers.

    Science.gov (United States)

    Jones, M; Welch, J; Turvey, J; Cannon, J; Clark, P; Szram, J; Cullinan, P

    2016-07-01

    Supermarket bakers are exposed not only to flour and alpha-amylase but also to other 'improver' enzymes, the nature of which is usually shrouded by commercial sensitivity. We aimed to determine the prevalence of sensitization to 'improver' enzymes in UK supermarket bakers. We examined the prevalence of sensitization to enzymes in 300 bakers, employed by one of two large supermarket bakeries, who had declared work-related respiratory symptoms during routine health surveillance. Sensitization was determined using radioallergosorbent assay to eight individual enzymes contained in the specific 'improver' mix used by each supermarket. The prevalence of sensitization to 'improver' enzymes ranged from 5% to 15%. Sensitization was far more likely if the baker was sensitized also to either flour or alpha-amylase. The prevalence of sensitization to an 'improver' enzyme did not appear to be related to the concentration of that enzyme in the mix. We report substantial rates of sensitization to enzymes other than alpha-amylase in UK supermarket bakers; in only a small proportion of bakers was there evidence of sensitization to 'improver mix' enzymes without sensitization to either alpha-amylase or flour. The clinical significance of these findings needs further investigation, but our findings indicate that specific sensitization in symptomatic bakers may not be identified without consideration of a wide range of workplace antigens. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Cost-Sensitive Feature Selection of Numeric Data with Measurement Errors

    Directory of Open Access Journals (Sweden)

    Hong Zhao

    2013-01-01

    Full Text Available Feature selection is an essential process in data mining applications since it reduces a model’s complexity. However, feature selection with various types of costs is still a new research topic. In this paper, we study the cost-sensitive feature selection problem of numeric data with measurement errors. The major contributions of this paper are fourfold. First, a new data model is built to address test costs and misclassification costs as well as error boundaries. It is distinguished from the existing models mainly on the error boundaries. Second, a covering-based rough set model with normal distribution measurement errors is constructed. With this model, coverings are constructed from data rather than assigned by users. Third, a new cost-sensitive feature selection problem is defined on this model. It is more realistic than the existing feature selection problems. Fourth, both backtracking and heuristic algorithms are proposed to deal with the new problem. Experimental results show the efficiency of the pruning techniques for the backtracking algorithm and the effectiveness of the heuristic algorithm. This study is a step toward realistic applications of the cost-sensitive learning.

  20. pH-Sensitive nanoparticles as smart carriers for selective intracellular drug delivery to tumor.

    Science.gov (United States)

    Li, Xin-Xin; Chen, Jing; Shen, Jian-Min; Zhuang, Ran; Zhang, Shi-Qi; Zhu, Zi-Yun; Ma, Jing-Bo

    2018-05-05

    Herein, a smart pH-sensitive nanoparticle (DGL-PEG-Tat-KK-DMA-DOX) was prepared to achieve the selective intracellular drug delivery. In this nanoparticle, a PEG-grafted cell penetrating peptide (PEG-Tat-KK) was designed and acted as the cell penetrating segment. By introducing the pH-sensitive amide bonds between the peptide and blocking agent (2,3-dimethylmaleic anhydride, DMA), the controllable moiety (PEG-Tat-KK-DMA) endowed the nanoparticle with a charge-switchable shell and temporarily blocked penetrating function, thus improving the specific internalization. Besides, dendrigraft poly-L-lysine (DGL) used as the skeleton can greatly improve the drug loading because of the highly dendritic framework. Under the stimuli of acidic pH, this nanoparticle exhibited a remarkable charge-switchable property. The drug release showed an expected behavior with little release in the neutral pH media but relatively fast release in the acidic media. The in vitro experiments revealed that the cellular uptake and cytotoxicity were significantly enhanced after the pH was decreased. In vivo biodistribution and antitumor research indicated that the nanoparticle had noteworthy specificity and antitumor efficacy with a tumor inhibition rate of 79.7%. These results verified this nanoparticle could efficiently improve the selective intracellular delivery and possessed a great potential in tumor treatment. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Post-CMOS selective electroplating technique for the improvement of CMOS-MEMS accelerometers

    International Nuclear Information System (INIS)

    Liu, Yu-Chia; Tsai, Ming-Han; Fang, Weileun; Tang, Tsung-Lin

    2011-01-01

    This study presents a simple approach to improve the performance of the CMOS-MEMS capacitive accelerometer by means of the post-CMOS metal electroplating process. The metal layer can be selectively electroplated on the MEMS structures at low temperature and the thickness of the metal layer can be easily adjusted by this process. Thus the performance of the capacitive accelerometer (i.e. sensitivity, noise floor and the minimum detectable signal) can be improved. In application, the proposed accelerometers have been implemented using (1) the standard CMOS 0.35 µm 2P4M process by CMOS foundry, (2) Ti/Au seed layers deposition/patterning by MEMS foundry and (3) in-house post-CMOS electroplating and releasing processes. Measurements indicate that the sensitivity is improved 2.85-fold, noise is decreased near 1.7-fold and the minimum detectable signal is improved from 1 to 0.2 G after nickel electroplating. Moreover, unwanted structure deformation due to the temperature variation is significantly suppressed by electroplated nickel.

  2. Genomic selection improves response to selection in resilience by exploiting genotype by environment interactions

    Directory of Open Access Journals (Sweden)

    Han Mulder

    2016-10-01

    Full Text Available Genotype by environment interactions (GxE are very common in livestock and hamper genetic improvement. On the other hand, GxE is a source of genetic variation: genetic variation in response to environment, e.g. environmental perturbations such as heat stress or disease. In livestock breeding, there is tendency to ignore GxE because of increased complexity of models for genetic evaluations and lack of accuracy in extreme environments. GxE, however, creates opportunities to increase resilience of animals towards environmental perturbations. The main aim of the paper is to investigate to which extent GxE can be exploited with traditional and genomic selection methods. Furthermore, we investigated the benefit of reaction norm models compared to conventional methods ignoring GxE. The questions were addressed with selection index theory. GxE was modelled according to a linear reaction norm model in which the environmental gradient is the contemporary group mean. Economic values were based on linear and non-linear profit equations.Accuracies of environment-specific (GEBV were highest in intermediate environments and lowest in extreme environments. Reaction norm models had higher accuracies of (GEBV in extreme environments than conventional models ignoring GxE. Genomic selection always resulted in higher response to selection in all environments than sib or progeny testing schemes. The increase in response was with genomic selection between 9% and 140% compared to sib testing and between 11% and 114% compared to progeny testing when the reference population consisted of 1 million animals across all environments. When the aim was to decrease environmental sensitivity, the response in slope of the reaction norm model with genomic selection was between 1.09 and 319 times larger than with sib or progeny testing and in the right direction in contrast to sib and progeny testing that still increased environmental sensitivity. This shows that genomic selection

  3. Magnetically-focusing biochip structures for high-speed active biosensing with improved selectivity

    Science.gov (United States)

    Yoo, Haneul; Lee, Dong Jun; Kim, Daesan; Park, Juhun; Chen, Xing; Hong, Seunghun

    2018-06-01

    We report a magnetically-focusing biochip structure enabling a single layered magnetic trap-and-release cycle for biosensors with an improved detection speed and selectivity. Here, magnetic beads functionalized with specific receptor molecules were utilized to trap target molecules in a solution and transport actively to and away from the sensor surfaces to enhance the detection speed and reduce the non-specific bindings, respectively. Using our method, we demonstrated the high speed detection of IL-13 antigens with the improved detection speed by more than an order of magnitude. Furthermore, the release step in our method was found to reduce the non-specific bindings and improve the selectivity and sensitivity of biosensors. This method is a simple but powerful strategy and should open up various applications such as ultra-fast biosensors for point-of-care services.

  4. Decoding facial expressions based on face-selective and motion-sensitive areas.

    Science.gov (United States)

    Liang, Yin; Liu, Baolin; Xu, Junhai; Zhang, Gaoyan; Li, Xianglin; Wang, Peiyuan; Wang, Bin

    2017-06-01

    Humans can easily recognize others' facial expressions. Among the brain substrates that enable this ability, considerable attention has been paid to face-selective areas; in contrast, whether motion-sensitive areas, which clearly exhibit sensitivity to facial movements, are involved in facial expression recognition remained unclear. The present functional magnetic resonance imaging (fMRI) study used multi-voxel pattern analysis (MVPA) to explore facial expression decoding in both face-selective and motion-sensitive areas. In a block design experiment, participants viewed facial expressions of six basic emotions (anger, disgust, fear, joy, sadness, and surprise) in images, videos, and eyes-obscured videos. Due to the use of multiple stimulus types, the impacts of facial motion and eye-related information on facial expression decoding were also examined. It was found that motion-sensitive areas showed significant responses to emotional expressions and that dynamic expressions could be successfully decoded in both face-selective and motion-sensitive areas. Compared with static stimuli, dynamic expressions elicited consistently higher neural responses and decoding performance in all regions. A significant decrease in both activation and decoding accuracy due to the absence of eye-related information was also observed. Overall, the findings showed that emotional expressions are represented in motion-sensitive areas in addition to conventional face-selective areas, suggesting that motion-sensitive regions may also effectively contribute to facial expression recognition. The results also suggested that facial motion and eye-related information played important roles by carrying considerable expression information that could facilitate facial expression recognition. Hum Brain Mapp 38:3113-3125, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  5. Short-term weight loss attenuates local tissue inflammation and improves insulin sensitivity without affecting adipose inflammation in obese mice.

    Science.gov (United States)

    Jung, Dae Young; Ko, Hwi Jin; Lichtman, Eben I; Lee, Eunjung; Lawton, Elizabeth; Ong, Helena; Yu, Kristine; Azuma, Yoshihiro; Friedline, Randall H; Lee, Ki Won; Kim, Jason K

    2013-05-01

    Obesity is a major cause of insulin resistance, and weight loss is shown to improve glucose homeostasis. But the underlying mechanism and the role of inflammation remain unclear. Male C57BL/6 mice were fed a high-fat diet (HFD) for 12 wk. After HFD, weight loss was induced by changing to a low-fat diet (LFD) or exercise with continuous HFD. The weight loss effects on energy balance and insulin sensitivity were determined using metabolic cages and hyperinsulinemic euglycemic clamps in awake mice. Diet and exercise intervention for 3 wk caused a modest weight loss and improved glucose homeostasis. Weight loss dramatically reduced local inflammation in skeletal muscle, liver, and heart but not in adipose tissue. Exercise-mediated weight loss increased muscle glucose metabolism without affecting Akt phosphorylation or lipid levels. LFD-mediated weight loss reduced lipid levels and improved insulin sensitivity selectively in liver. Both weight loss interventions improved cardiac glucose metabolism. These results demonstrate that a short-term weight loss with exercise or diet intervention attenuates obesity-induced local inflammation and selectively improves insulin sensitivity in skeletal muscle and liver. Our findings suggest that local factors, not adipose tissue inflammation, are involved in the beneficial effects of weight loss on glucose homeostasis.

  6. Using genomic DNA-based probe-selection to improve the sensitivity of high-density oligonucleotide arrays when applied to heterologous species

    Directory of Open Access Journals (Sweden)

    Townsend Henrik J

    2005-11-01

    Full Text Available Abstract High-density oligonucleotide (oligo arrays are a powerful tool for transcript profiling. Arrays based on GeneChip® technology are amongst the most widely used, although GeneChip® arrays are currently available for only a small number of plant and animal species. Thus, we have developed a method to improve the sensitivity of high-density oligonucleotide arrays when applied to heterologous species and tested the method by analysing the transcriptome of Brassica oleracea L., a species for which no GeneChip® array is available, using a GeneChip® array designed for Arabidopsis thaliana (L. Heynh. Genomic DNA from B. oleracea was labelled and hybridised to the ATH1-121501 GeneChip® array. Arabidopsis thaliana probe-pairs that hybridised to the B. oleracea genomic DNA on the basis of the perfect-match (PM probe signal were then selected for subsequent B. oleracea transcriptome analysis using a .cel file parser script to generate probe mask files. The transcriptional response of B. oleracea to a mineral nutrient (phosphorus; P stress was quantified using probe mask files generated for a wide range of gDNA hybridisation intensity thresholds. An example probe mask file generated with a gDNA hybridisation intensity threshold of 400 removed > 68 % of the available PM probes from the analysis but retained >96 % of available A. thaliana probe-sets. Ninety-nine of these genes were then identified as significantly regulated under P stress in B. oleracea, including the homologues of P stress responsive genes in A. thaliana. Increasing the gDNA hybridisation intensity thresholds up to 500 for probe-selection increased the sensitivity of the GeneChip® array to detect regulation of gene expression in B. oleracea under P stress by up to 13-fold. Our open-source software to create probe mask files is freely available http://affymetrix.arabidopsis.info/xspecies/ and may be used to facilitate transcriptomic analyses of a wide range of plant and animal

  7. Improved Sensitivity of Spectroscopic Quantification of Stable Isotope Content Using Capillary Absorption Spectroscopy

    Science.gov (United States)

    Moran, J.; Wilcox Freeburg, E.; Kriesel, J.; Linley, T. J.; Kelly, J.; Coleman, M. L.; Christensen, L. E.; Vance, S.

    2016-12-01

    Spectroscopy-based platforms have recently risen to the forefront for making stable isotope measurements of methane, carbon dioxide, water, or other analytes. These spectroscopy systems can be relatively straightforward to operate (versus a mass spectrometry platform), largely relieve the analyst of mass interference artifacts, and many can be used in the field. Despite these significant advantages, however, existing spectroscopy techniques suffer from a lack of measurement sensitivity that can ultimately limit select applications including spatially resolved and compound-specific measurements. Here we present a capillary absorption spectroscopy (CAS) system that is designed to mitigate sensitivity issues in spectroscopy-based stable isotope evaluation. The system uses mid-wave infrared excitation generated from a continuous wave quantum cascade laser. Importantly, the sample `chamber' is a flexible capillary with a total volume of less than one cc. Proprietary coatings on the internal surface of the fiber improve optical performance, guiding the light to a detector and facilitating high levels of interaction between the laser beam and gaseous analytes. We present data demonstrating that a tapered hollow fiber cell, with an internal diameter that broadens toward the detector, reduces optical feedback to further improve measurement sensitivity. Sensitivity of current hollow fiber / CAS systems enable measurements of only 10's of picomoles CO2 while theoretical improvements should enable measurements of as little as 10's of femtomoles. Continued optimization of sample introduction and improvements to optical feedback are being explored. Software is being designed to provide rapid integration of data and generation of processed isotope measurements using a graphical user interface. Taken together, the sensitivity improvements of the CAS system under development could, when coupled to a laser ablation sampling device, enable up to 2 µm spatial resolution (roughly the

  8. Real-time pure shift {sup 15}N HSQC of proteins: a real improvement in resolution and sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Kiraly, Peter; Adams, Ralph W.; Paudel, Liladhar; Foroozandeh, Mohammadali [University of Manchester, School of Chemistry (United Kingdom); Aguilar, Juan A. [Durham University, Department of Chemistry (United Kingdom); Timári, István [University of Debrecen, Department of Inorganic and Analytical Chemistry (Hungary); Cliff, Matthew J. [University of Manchester, Manchester Institute of Biotechnology (United Kingdom); Nilsson, Mathias [University of Manchester, School of Chemistry (United Kingdom); Sándor, Péter [Agilent Technologies R& D and Marketing GmbH & Co. KG (Germany); Batta, Gyula [University of Debrecen, Department of Organic Chemistry (Hungary); Waltho, Jonathan P. [University of Manchester, Manchester Institute of Biotechnology (United Kingdom); Kövér, Katalin E. [University of Debrecen, Department of Inorganic and Analytical Chemistry (Hungary); Morris, Gareth A., E-mail: g.a.morris@manchester.ac.uk [University of Manchester, School of Chemistry (United Kingdom)

    2015-05-15

    Spectral resolution in proton NMR spectroscopy is reduced by the splitting of resonances into multiplets due to the effect of homonuclear scalar couplings. Although these effects are often hidden in protein NMR spectroscopy by low digital resolution and routine apodization, behind the scenes homonuclear scalar couplings increase spectral overcrowding. The possibilities for biomolecular NMR offered by new pure shift NMR methods are illustrated here. Both resolution and sensitivity are improved, without any increase in experiment time. In these experiments, free induction decays are collected in short bursts of data acquisition, with durations short on the timescale of J-evolution, interspersed with suitable refocusing elements. The net effect is real-time (t{sub 2}) broadband homodecoupling, suppressing the multiplet structure caused by proton–proton interactions. The key feature of the refocusing elements is that they discriminate between the resonances of active (observed) and passive (coupling partner) spins. This can be achieved either by using band-selective refocusing or by the BIRD element, in both cases accompanied by a nonselective 180° proton pulse. The latter method selects the active spins based on their one-bond heteronuclear J-coupling to {sup 15}N, while the former selects a region of the {sup 1}H spectrum. Several novel pure shift experiments are presented, and the improvements in resolution and sensitivity they provide are evaluated for representative samples: the N-terminal domain of PGK; ubiquitin; and two mutants of the small antifungal protein PAF. These new experiments, delivering improved sensitivity and resolution, have the potential to replace the current standard HSQC experiments.

  9. Sensitivity, selectivity and stability of tin oxide nanostructures on large area arrays of microhotplates

    Science.gov (United States)

    Panchapakesan, Balaji; Cavicchi, Richard; Semancik, Steve; DeVoe, Don L.

    2006-01-01

    In this paper, the sensitivity, stability and selectivity of nanoparticle engineered tin oxide (SnO2) are reported, for microhotplate chemical sensing applications. 16 Å of metals such as nickel, cobalt, iron, copper and silver were selectively evaporated onto each column of the microhotplate array. Following evaporation, the microhotplates were heated to 500 °C and SnO2 was deposited on top of the microhotplates using a self-aligned chemical vapour deposition process. Scanning electron microscopy characterization revealed control of SnO2 nanostructures in the range of 20-121 nm. Gas sensing in seven different hydrocarbons revealed that metal nanoparticles that helped in producing faster nucleation of SnO2 resulted in smaller grain size and higher sensitivity. Sensitivity as a function of concentration and grain size is addressed for tin oxide nanostructures. Smaller grain sizes resulted in higher sensitivity of tin oxide nanostructures. Temperature programmed sensing of the devices yielded shape differences in the response between air and methanol, illustrating selectivity. Spiderweb plots were used to monitor the materials programmed selectivity. The shape differences between different gases in spiderweb plots illustrate materials selectivity as a powerful mapping approach for monitoring selectivity in various gases. Continuous monitoring in 80 ppm methanol yielded stable sensor response for more than 200 h. This comprehensive study illustrates the use of a nanoparticle engineering approach for sensitive, selective and stable gas sensing applications.

  10. Culture, Personality, Health, and Family Dynamics: Cultural Competence in the Selection of Culturally Sensitive Treatments

    Science.gov (United States)

    Sperry, Len

    2010-01-01

    Cultural sensitivity and cultural competence in the selection of culturally sensitive treatments is a requisite for effective counseling practice in working with diverse clients and their families, particularly when clients present with health issues or medical problems. Described here is a strategy for selecting culturally sensitive treatments…

  11. Hydraulic head interpolation using ANFIS—model selection and sensitivity analysis

    Science.gov (United States)

    Kurtulus, Bedri; Flipo, Nicolas

    2012-01-01

    The aim of this study is to investigate the efficiency of ANFIS (adaptive neuro fuzzy inference system) for interpolating hydraulic head in a 40-km 2 agricultural watershed of the Seine basin (France). Inputs of ANFIS are Cartesian coordinates and the elevation of the ground. Hydraulic head was measured at 73 locations during a snapshot campaign on September 2009, which characterizes low-water-flow regime in the aquifer unit. The dataset was then split into three subsets using a square-based selection method: a calibration one (55%), a training one (27%), and a test one (18%). First, a method is proposed to select the best ANFIS model, which corresponds to a sensitivity analysis of ANFIS to the type and number of membership functions (MF). Triangular, Gaussian, general bell, and spline-based MF are used with 2, 3, 4, and 5 MF per input node. Performance criteria on the test subset are used to select the 5 best ANFIS models among 16. Then each is used to interpolate the hydraulic head distribution on a (50×50)-m grid, which is compared to the soil elevation. The cells where the hydraulic head is higher than the soil elevation are counted as "error cells." The ANFIS model that exhibits the less "error cells" is selected as the best ANFIS model. The best model selection reveals that ANFIS models are very sensitive to the type and number of MF. Finally, a sensibility analysis of the best ANFIS model with four triangular MF is performed on the interpolation grid, which shows that ANFIS remains stable to error propagation with a higher sensitivity to soil elevation.

  12. Sensitivity and Resolution Improvement in RGBW Color Filter Array Sensor

    Directory of Open Access Journals (Sweden)

    Seunghoon Jee

    2018-05-01

    Full Text Available Recently, several red-green-blue-white (RGBW color filter arrays (CFAs, which include highly sensitive W pixels, have been proposed. However, RGBW CFA patterns suffer from spatial resolution degradation owing to the sensor composition having more color components than the Bayer CFA pattern. RGBW CFA demosaicing methods reconstruct resolution using the correlation between white (W pixels and pixels of other colors, which does not improve the red-green-blue (RGB channel sensitivity to the W channel level. In this paper, we thus propose a demosaiced image post-processing method to improve the RGBW CFA sensitivity and resolution. The proposed method decomposes texture components containing image noise and resolution information. The RGB channel sensitivity and resolution are improved through updating the W channel texture component with those of RGB channels. For this process, a cross multilateral filter (CMF is proposed. It decomposes the smoothness component from the texture component using color difference information and distinguishes color components through that information. Moreover, it decomposes texture components, luminance noise, color noise, and color aliasing artifacts from the demosaiced images. Finally, by updating the texture of the RGB channels with the W channel texture components, the proposed algorithm improves the sensitivity and resolution. Results show that the proposed method is effective, while maintaining W pixel resolution characteristics and improving sensitivity from the signal-to-noise ratio value by approximately 4.5 dB.

  13. 13C spin relaxation measurements in RNA: Sensitivity and resolution improvement using spin-state selective correlation experiments

    International Nuclear Information System (INIS)

    Boisbouvier, Jerome; Brutscher, Bernhard; Simorre, Jean-Pierre; Marion, Dominique

    1999-01-01

    A set of new NMR pulse sequences has been designed for the measurement of 13 C relaxation rate constants in RNA and DNA bases: the spin-lattice relaxation rate constant R(C z ), the spin-spin relaxation rate constant R(C + ), and the CSA-dipolar cross-correlated relaxation rate constant Γ C,CH xy . The use of spin-state selective correlation techniques provides increased sensitivity and spectral resolution. Sensitivity optimised C-C filters are included in the pulse schemes for the suppression of signals originating from undesired carbon isotopomers. The experiments are applied to a 15% 13 C-labelled 33-mer RNA-theophylline complex. The measured R(C + )/Γ C,CH xy ratios indicate that 13 C CSA tensors do not vary significantly for the same type of carbon (C 2 , C 6 , C 8 ), but that they differ from one type to another. In addition, conformational exchange effects in the RNA bases are detected as a change in the relaxation decay of the narrow 13 C doublet component when varying the spacing of a CPMG pulse train. This new approach allows the detection of small exchange effects with a higher precision compared to conventional techniques

  14. Highly Sensitive and Selective Potassium Ion Detection Based on Graphene Hall Effect Biosensors

    Directory of Open Access Journals (Sweden)

    Xiangqi Liu

    2018-03-01

    Full Text Available Potassium (K+ ion is an important biological substance in the human body and plays a critical role in the maintenance of transmembrane potential and hormone secretion. Several detection techniques, including fluorescent, electrochemical, and electrical methods, have been extensively investigated to selectively recognize K+ ions. In this work, a highly sensitive and selective biosensor based on single-layer graphene has been developed for K+ ion detection under Van der Pauw measurement configuration. With pre-immobilization of guanine-rich DNA on the graphene surface, the graphene devices exhibit a very low limit of detection (≈1 nM with a dynamic range of 1 nM–10 μM and excellent K+ ion specificity against other alkali cations, such as Na+ ions. The origin of K+ ion selectivity can be attributed to the fact that the formation of guanine-quadruplexes from guanine-rich DNA has a strong affinity for capturing K+ ions. The graphene-based biosensors with improved sensing performance for K+ ion recognition can be applied to health monitoring and early disease diagnosis.

  15. TreePOD: Sensitivity-Aware Selection of Pareto-Optimal Decision Trees.

    Science.gov (United States)

    Muhlbacher, Thomas; Linhardt, Lorenz; Moller, Torsten; Piringer, Harald

    2018-01-01

    Balancing accuracy gains with other objectives such as interpretability is a key challenge when building decision trees. However, this process is difficult to automate because it involves know-how about the domain as well as the purpose of the model. This paper presents TreePOD, a new approach for sensitivity-aware model selection along trade-offs. TreePOD is based on exploring a large set of candidate trees generated by sampling the parameters of tree construction algorithms. Based on this set, visualizations of quantitative and qualitative tree aspects provide a comprehensive overview of possible tree characteristics. Along trade-offs between two objectives, TreePOD provides efficient selection guidance by focusing on Pareto-optimal tree candidates. TreePOD also conveys the sensitivities of tree characteristics on variations of selected parameters by extending the tree generation process with a full-factorial sampling. We demonstrate how TreePOD supports a variety of tasks involved in decision tree selection and describe its integration in a holistic workflow for building and selecting decision trees. For evaluation, we illustrate a case study for predicting critical power grid states, and we report qualitative feedback from domain experts in the energy sector. This feedback suggests that TreePOD enables users with and without statistical background a confident and efficient identification of suitable decision trees.

  16. Selection of resistance and sensitive cultivars of lentil in Ardabil ...

    African Journals Online (AJOL)

    Selection of resistance and sensitive cultivars of lentil in Ardabil region of Iran ... irrigation from planting until maturity and non-irrigation from seed emergence ... Key words: Lentil, yield, normal and stress conditions, drought tolerance index.

  17. Selective and sensitive detection of chromium(VI) in waters using electrospray ionization mass spectrometry.

    Science.gov (United States)

    Weldy, Effie; Wolff, Chloe; Miao, Zhixin; Chen, Hao

    2013-09-01

    From 2000 through 2011, there were 14 criminal cases of violations of the Clean Water Act involving the discharge of chromium, a toxic heavy metal, into drinking and surface water sources. As chromium(VI), a potential carcinogen present in the environment, represents a significant safety concern, it is currently the subject of an EPA health risk assessment. Therefore, sensitive and selective detection of this species is highly desired. This study reports the analysis of chromium(VI) in water samples by electrospray ionization mass spectrometry (ESI-MS) following its reduction and complexation with ammonium pyrrolidinedithiocarbamate (APDC). The reduction and subsequent complexation produce a characteristic [Cr(III)O]-PDC complex which can be detected as a protonated ion of m/z 507 in the positive ion mode. The detection is selective to chromium(VI) under acidic pH, even in the presence of chromium(III) and other metal ions, providing high specificity. Different water samples were examined, including deionized, tap, and river waters, and sensitive detection was achieved. In the case of deionized water, quantification over the concentration range of 3.7 to 148ppb gave an excellent correlation coefficient of 0.9904 using the enhanced MS mode scan. Using the single-reaction monitoring (SRM) mode (monitoring the characteristic fragmentation of m/z 507 to m/z 360), the limit of detection (LOD) was found to be 0.25ppb. The LOD of chromium(VI) for both tap and river water samples was determined to be 2.0ppb. A preconcentration strategy using simple vacuum evaporation of the aqueous sample was shown to further improve the ESI signal by 15 fold. This method, with high sensitivity and selectivity, should provide a timely solution for the real-world analysis of toxic chromium(VI). Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  18. Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Tujin; Su, Dian; Liu, Tao; Tang, Keqi; Camp, David G.; Qian, Weijun; Smith, Richard D.

    2012-04-01

    Selected reaction monitoring (SRM)—also known as multiple reaction monitoring (MRM)—has emerged as a promising high-throughput targeted protein quantification technology for candidate biomarker verification and systems biology applications. A major bottleneck for current SRM technology, however, is insufficient sensitivity for e.g., detecting low-abundance biomarkers likely present at the pg/mL to low ng/mL range in human blood plasma or serum, or extremely low-abundance signaling proteins in the cells or tissues. Herein we review recent advances in methods and technologies, including front-end immunoaffinity depletion, fractionation, selective enrichment of target proteins/peptides or their posttranslational modifications (PTMs), as well as advances in MS instrumentation, which have significantly enhanced the overall sensitivity of SRM assays and enabled the detection of low-abundance proteins at low to sub- ng/mL level in human blood plasma or serum. General perspectives on the potential of achieving sufficient sensitivity for detection of pg/mL level proteins in plasma are also discussed.

  19. Enhanced leptin sensitivity and improved glucose homeostasis in mice lacking suppressor of cytokine signaling-3 in POMC-expressing cells.

    Science.gov (United States)

    Kievit, Paul; Howard, Jane K; Badman, Michael K; Balthasar, Nina; Coppari, Roberto; Mori, Hiroyuki; Lee, Charlotte E; Elmquist, Joel K; Yoshimura, Akihiko; Flier, Jeffrey S

    2006-08-01

    Suppressor of cytokine signaling-3 (Socs-3) negatively regulates the action of various cytokines, as well as the metabolic hormones leptin and insulin. Mice with haploinsufficiency of Socs-3, or those with neuronal deletion of Socs-3, are lean and more leptin and insulin sensitive. To examine the role of Socs-3 within specific neurons critical to energy balance, we created mice with selective deletion of Socs-3 within pro-opiomelanocortin (POMC)-expressing cells. These mice had enhanced leptin sensitivity, measured by weight loss and food intake after leptin infusion. On chow diet, glucose homeostasis was improved despite normal weight gain. On a high-fat diet, the rate of weight gain was reduced, due to increased energy expenditure rather than decreased food intake; glucose homeostasis and insulin sensitivity were substantially improved. These studies demonstrate that Socs-3 within POMC neurons regulates leptin sensitivity and glucose homeostasis, and plays a key role in linking high-fat diet to disordered metabolism.

  20. 3-[2,4-Dimethoxybenzylidene]anabaseine (DMXB) selectively activates rat alpha7 receptors and improves memory-related behaviors in a mecamylamine-sensitive manner.

    Science.gov (United States)

    Meyer, E M; Tay, E T; Papke, R L; Meyers, C; Huang, G L; de Fiebre, C M

    1997-09-12

    The alpha7 nicotinic receptor agonist 3-[2,4-dimethoxybenzylidene]anabaseine (DMXB; GTS-21) was investigated for its ability to: (1) activate a variety of nicotinic receptor subtypes in Xenopus oocytes; (2) improve passive avoidance and spatial Morris water task performances in mecamylamine-sensitive manners in bilaterally nucleus basalis lesioned rats; and (3) elevate high-affinity [3H]acetylcholine (ACh) and high-affinity alpha-[125I]bungarotoxin binding in rat neocortex following 2 weeks of daily injections. DMXB (100 microM) activated alpha7 homo-oligomeric receptors, without significant activity at alpha2-, alpha3- and alpha4-containing subtypes. Mecamylamine blocked rat alpha7 receptors weakly if co-administered with agonist, but much more potently when pre-applied. Bilateral ibotenic acid lesions of the nucleus basalis interfered with passive avoidance and spatial memory-related behaviors. DMXB (0.5 mg/kg, i.p.) improved passive avoidance behavior in lesioned animals in a mecamylamine-sensitive manner. DMXB (0.5 mg/kg 15 min before each session) also improved performance in the training and probe components of the Morris water task. DMXB-induced improvement in the probe component but not the training phase was mecamylamine-sensitive. [3H]ACh binding was elevated after 14 days of daily i.p. injections with 0.2 mg/kg nicotine but not after 1 mg/kg DMXB. Neither drug elevated high-affinity alpha-[125I]bungarorotoxin binding over this interval.

  1. Modification of a deoxynivalenol-antigen-mimicking nanobody to improve immunoassay sensitivity by site-saturation mutagenesis.

    Science.gov (United States)

    Qiu, Yu-Lou; He, Qing-Hua; Xu, Yang; Wang, Wei; Liu, Yuan-Yuan

    2016-01-01

    A nanobody (N-28) which can act as a deoxynivalenol (DON) antigen has been generated, and its residues Thr102-Ser106 were identified to bind with anti-DON monoclonal antibody by alanine-scanning mutagenesis. Site-saturation mutagenesis was used to analyze the plasticity of five residues and to improve the sensitivity of the N-28-based immunoassay. After mutagenesis, three mutants were selected by phage immunoassay and were sequenced. The half-maximal inhibitory concentrations of the immunoassay based on mutants N-28-T102Y, N-28-V103L, and N-28-Y105F were 24.49 ± 1.0, 51.83 ± 2.5, and 35.65 ± 1.6 ng/mL, respectively, showing the assay was, respectively, 3.2, 1.5, and 2.2 times more sensitive than the wild-type-based assay. The best mutant, N-28-T102Y, was used to develop a competitive phage ELISA to detect DON in cereals with high specificity and accuracy. In addition, the structural properties of N-28-T102Y and N-28 were investigated, revealing that the affinity of N-28-T102Y decreased because of increased steric hindrance with the large side chain. The lower-binding-affinity antigen mimetic may contribute to the improvement of the sensitivity of competitive immunoassays. These results demonstrate that nanobodies would be a favorable tool for engineering. Moreover, our results have laid a solid foundation for site-saturation mutagenesis of antigen-mimicking nanobodies to improve immunoassay sensitivity for small molecules.

  2. DNA Antenna Tile-Associated Deoxyribozyme Sensor with Improved Sensitivity.

    Science.gov (United States)

    Cox, Amanda J; Bengtson, Hillary N; Gerasimova, Yulia V; Rohde, Kyle H; Kolpashchikov, Dmitry M

    2016-11-03

    Some natural enzymes increase the rate of diffusion-limited reactions by facilitating substrate flow to their active sites. Inspired by this natural phenomenon, we developed a strategy for efficient substrate delivery to a deoxyribozyme (DZ) catalytic sensor. This resulted in a three- to fourfold increase in sensitivity and up to a ninefold improvement in the detection limit. The reported strategy can be used to enhance catalytic efficiency of diffusion-limited enzymes and to improve sensitivity of enzyme-based biosensors. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Selecting Sensitive Parameter Subsets in Dynamical Models With Application to Biomechanical System Identification.

    Science.gov (United States)

    Ramadan, Ahmed; Boss, Connor; Choi, Jongeun; Peter Reeves, N; Cholewicki, Jacek; Popovich, John M; Radcliffe, Clark J

    2018-07-01

    Estimating many parameters of biomechanical systems with limited data may achieve good fit but may also increase 95% confidence intervals in parameter estimates. This results in poor identifiability in the estimation problem. Therefore, we propose a novel method to select sensitive biomechanical model parameters that should be estimated, while fixing the remaining parameters to values obtained from preliminary estimation. Our method relies on identifying the parameters to which the measurement output is most sensitive. The proposed method is based on the Fisher information matrix (FIM). It was compared against the nonlinear least absolute shrinkage and selection operator (LASSO) method to guide modelers on the pros and cons of our FIM method. We present an application identifying a biomechanical parametric model of a head position-tracking task for ten human subjects. Using measured data, our method (1) reduced model complexity by only requiring five out of twelve parameters to be estimated, (2) significantly reduced parameter 95% confidence intervals by up to 89% of the original confidence interval, (3) maintained goodness of fit measured by variance accounted for (VAF) at 82%, (4) reduced computation time, where our FIM method was 164 times faster than the LASSO method, and (5) selected similar sensitive parameters to the LASSO method, where three out of five selected sensitive parameters were shared by FIM and LASSO methods.

  4. Tailoring force sensitivity and selectivity by microstructure engineering of multidirectional electronic skins

    Science.gov (United States)

    Park, Jonghwa; Kim, Jinyoung; Hong, Jaehyung; Lee, Hochan; Lee, Youngoh; Cho, Seungse; Kim, Sung-Woo; Kim, Jae Joon; Kim, Sung Youb; Ko, Hyunhyub

    2018-04-01

    Electronic skins (e-skins) with high sensitivity to multidirectional mechanical stimuli are crucial for healthcare monitoring devices, robotics, and wearable sensors. In this study, we present piezoresistive e-skins with tunable force sensitivity and selectivity to multidirectional forces through the engineered microstructure geometries (i.e., dome, pyramid, and pillar). Depending on the microstructure geometry, distinct variations in contact area and localized stress distribution are observed under different mechanical forces (i.e., normal, shear, stretching, and bending), which critically affect the force sensitivity, selectivity, response/relaxation time, and mechanical stability of e-skins. Microdome structures present the best force sensitivities for normal, tensile, and bending stresses. In particular, microdome structures exhibit extremely high pressure sensitivities over broad pressure ranges (47,062 kPa-1 in the range of <1 kPa, 90,657 kPa-1 in the range of 1-10 kPa, and 30,214 kPa-1 in the range of 10-26 kPa). On the other hand, for shear stress, micropillar structures exhibit the highest sensitivity. As proof-of-concept applications in healthcare monitoring devices, we show that our e-skins can precisely monitor acoustic waves, breathing, and human artery/carotid pulse pressures. Unveiling the relationship between the microstructure geometry of e-skins and their sensing capability would provide a platform for future development of high-performance microstructured e-skins.

  5. ENHANCEMENT OF THE SENSITIVITY AND SELECTIVITY OF THE VOLTAMMETRIC SENSOR FOR URIC ACID USING MOLECULARLY IMPRINTED POLYMER

    Directory of Open Access Journals (Sweden)

    Miratul Khasanah

    2010-12-01

    Full Text Available The sensitivity and selectivity of voltammetric sensor for uric acid can be improved by modifying the working electrode using a polymer with a molecular template (molecularly imprinted polymer, MIP. Polymer and MIP was synthesized from methacrylic acid (MAA as monomer, ethylene glycol dimethacrylic acid (EGDMA as cross-linker, uric acid (UA as template and the results were characterized by various methods. The poly-MAA formation was identified by a decrease in the intensity of infrared (IR spectra at ~1540 cm-1 (C=C and an increase at ~1700 cm-1 (C=O compared to the IR spectra of the MAA and EGDMA. The SEM analysis showed that the cavity of polymer is small enough (~ 0.1 µm and homogeneous. Establishment of MIP was carried out by extracting of the uric acid from the polymer network. The IR spectra of MIP exhibited the decrease in intensity at ~1700 cm-1 (C=O compared to the non imprinted polymer (NIP. The data of BET analysis showed that polymer pore size increase slightly from 37.71 Å to 38.02 Å after the extraction process of uric acid from the polymer network. Its may be due to incomplete extraction of uric acid from the polymer network. Modifications of hanging mercury drop electrode using MIP made from MAA, EGDMA, and UA with a mole ratio of 1:3:1 produced a sensitive and selective voltammetric sensor for uric acid. The sensitivity obtained was 16.405 nA L/µg. The presence of ascorbic acid in equal concentration with uric acid decreased the current response of only 0.08%. Compared to HMDE electrode, the sensitivity and selectivity of the HMDE-MIP sensor enhanced about 100 and 700 times, respectively. The detection limit was found to be 5.94 x10-10 M.

  6. Selective synthesis and characterization of chlorins as sensitizers for photodynamic therapy

    Science.gov (United States)

    Montforts, Franz-Peter; Kusch, Dirk; Hoper, Frank; Braun, Stefan; Gerlach, Benjamin; Brauer, Hans-Dieter; Schermann, Guido; Moser, Joerg G.

    1996-04-01

    Chlorin type sensitizers have ideal photophysical properties for an application in PDT. The basic chlorin framework of these sensitizers has to be modified by attachment of lipophilic and hydrophilic residues to achieve a good cell uptake and tumor enrichment. In the present study we describe the selective synthesis of amphiphilic chlorins starting from the readily accessible red blood pigment heme. The photophysical properties of the well defined synthetic chlorins are characterized by photophysical investigations. The kinetic of cell uptake, the localization in the cell and the photodynamic behavior of the amphiphilic sensitizers are demonstrated by incubation of A 375 cancer cell lines with structurally different chlorins.

  7. Nonmaternal Care's Association With Mother's Parenting Sensitivity: A Case of Self-Selection Bias?

    Science.gov (United States)

    Nomaguchi, Kei M; Demaris, Alfred

    2013-06-01

    Although attachment theory posits that the use of nonmaternal care undermines quality of mothers' parenting, empirical evidence for this link is inconclusive. Using data from the National Institute of Child Health and Human Development Study of Early Child Care and Youth Development ( N = 1,233), the authors examined the associations between nonmaternal care characteristics and maternal sensitivity during the first 3 years of children's lives, with special attention to selection effects and moderation by resource levels. Findings from fixed-effects regression models suggested that, on average, there is little relationship between nonmaternal care characteristics and maternal sensitivity, once selection factors are held constant. Some evidence of moderation effects was found, however. Excellent-quality care is related to more sensitivity for mothers with lower family income. Poor-quality care is related to lower sensitivity for single mothers, but not partnered mothers. In sum, nonmaternal care characteristics do not seem to have as much influence on mothers' parenting as attachment theory claims.

  8. A Sensitive Secondary Users Selection Algorithm for Cognitive Radio Ad Hoc Networks

    Directory of Open Access Journals (Sweden)

    Aohan Li

    2016-03-01

    Full Text Available Secondary Users (SUs are allowed to use the temporarily unused licensed spectrum without disturbing Primary Users (PUs in Cognitive Radio Ad Hoc Networks (CRAHNs. Existing architectures for CRAHNs impose energy-consuming Cognitive Radios (CRs on SUs. However, the advanced CRs will increase energy cost for their cognitive functionalities, which is undesirable for the battery powered devices. A new architecture referred to as spectral Requirement-based CRAHN (RCRAHN is proposed to enhance energy efficiency for CRAHNs in this paper. In RCRAHNs, only parts of SUs are equipped with CRs. SUs equipped with CRs are referred to as Cognitive Radio Users (CRUs. To further enhance energy efficiency of CRAHNs, we aim to select minimum CRUs to sense available spectrum. A non-linear programming problem is mathematically formulated under the constraints of energy efficiency and real-time. Considering the NP-hardness of the problem, a framework of a heuristic algorithm referred to as Sensitive Secondary Users Selection (SSUS was designed to compute the near-optimal solutions. The simulation results demonstrate that SSUS not only improves the energy efficiency, but also achieves satisfied performances in end-to-end delay and communication reliability.

  9. A Sensitive Secondary Users Selection Algorithm for Cognitive Radio Ad Hoc Networks.

    Science.gov (United States)

    Li, Aohan; Han, Guangjie; Wan, Liangtian; Shu, Lei

    2016-03-26

    Secondary Users (SUs) are allowed to use the temporarily unused licensed spectrum without disturbing Primary Users (PUs) in Cognitive Radio Ad Hoc Networks (CRAHNs). Existing architectures for CRAHNs impose energy-consuming Cognitive Radios (CRs) on SUs. However, the advanced CRs will increase energy cost for their cognitive functionalities, which is undesirable for the battery powered devices. A new architecture referred to as spectral Requirement-based CRAHN (RCRAHN) is proposed to enhance energy efficiency for CRAHNs in this paper. In RCRAHNs, only parts of SUs are equipped with CRs. SUs equipped with CRs are referred to as Cognitive Radio Users (CRUs). To further enhance energy efficiency of CRAHNs, we aim to select minimum CRUs to sense available spectrum. A non-linear programming problem is mathematically formulated under the constraints of energy efficiency and real-time. Considering the NP-hardness of the problem, a framework of a heuristic algorithm referred to as Sensitive Secondary Users Selection (SSUS) was designed to compute the near-optimal solutions. The simulation results demonstrate that SSUS not only improves the energy efficiency, but also achieves satisfied performances in end-to-end delay and communication reliability.

  10. Selective Intercultural Sensitivity to Different Sources of Cultural Identity: Study of Intercultural Sensitivity of Students at Teacher Education Programs of Georgia

    Science.gov (United States)

    Tabatadze, Shalva; Gorgadze, Natia

    2018-01-01

    Purpose: The purpose of this paper is to assess the intercultural sensitivity of students in teacher educational programs at higher education institutes (HEIs) in Georgia. Design/methodology/approach: This research explored the intercultural sensitivity among 355 randomly selected students in teacher education programs at higher education…

  11. New membrane materials for potassium-selective ion-sensitive field-effect transistors

    NARCIS (Netherlands)

    van der Wal, P.D.; van der Wal, Peter D.; Skowronska-Ptasinska, Maria; van den Berg, Albert; Bergveld, Piet; Sudholter, Ernst; Sudholter, Ernst J.R.; Reinhoudt, David

    1990-01-01

    Several polymeric materials were studied as membrane materials for potassium-selective ion-sensitive field-effect transistors (ISFETs) to overcome the problems related with the use of conventional plasticized poly(vinyl chloride) membranes casted on ISFET gate surfaces. Several acrylate materials,

  12. Responses to cholinergic agonists of rats selectively bred for differential sensitivity to ethanol.

    Science.gov (United States)

    de Fiebre, C M; Romm, E; Collins, J T; Draski, L J; Deitrich, R A; Collins, A C

    1991-03-01

    Alcoholics are almost invariably heavy users of tobacco. Both alcoholism and smoking appear to be influenced by genetic factors but it is not known whether the same or different genes regulate the abuse of ethanol and nicotine. Recent studies have demonstrated that the long-sleep (LS) and short-sleep (SS) mouse lines, which were selectively bred for differences in ethanol-induced anesthesia ("sleep-time"), also differ in several effects of nicotine and the muscarinic agonist, oxotremorine. In order to determine whether or not these differences are due to chance, the relative sensitivities of rat lines which were selectively bred for differences in ethanol-induced sleep-time were determined. The high alcohol sensitivity (HAS) rat line was more sensitive to the locomotor and body temperature depressant effects of nicotine than was the low alcohol sensitivity (LAS) rat line. The control line (CAS) was intermediate in sensitivity. The rat lines did not differ in sensitivity to oxotremorine's hypothermia-producing effects. The numbers and affinities of two classes of brain nicotinic receptors were measured in eight brain regions. No differences among the rat lines were detected. These results suggest that ethanol elicits some of its depressant actions via an effect on brain nicotinic systems, but the differences in sensitivity to ethanol and nicotine are probably not due to differences in the number of brain nicotinic receptors. Perhaps this interaction explains the high correlation between alcoholism and smoking in humans.

  13. Size-controlled sensitivity and selectivity for the fluorometric detection of Ag+ by homocysteine capped CdTe quantum dots

    International Nuclear Information System (INIS)

    Jiao, Hangzhou; Liang, Zhenhua; Peng, Guihua; Zhang, Ling; Lin, Hengwei

    2014-01-01

    We have synthesized water dispersible CdTe quantum dots (QDs) in different sizes and with various capping reagents, and have studied the effects of their size on the sensitivity and selectivity in the fluorometric determination of metal ions, particularly of silver(I). It is found that an increase in the particle size of homocysteine-capped CdTe QDs from 1.7 nm to 3.3 nm and to 3.7 nm enhances both the sensitivity and selectivity of the determination of Ag(I) to give an ultimate limit of detection as low as 8.3 nM. This effect can partially be explained by the better passivation of surface traps on smaller sized QDs via adsorption of Ag(I), thereby decreasing the apparent detection efficiency. In addition, the presence of CdS in the CdTe QDs is likely to play a role. The study demonstrates that an improvement in sensing performance is accomplished by using QDs of fine-tuned particle sizes. Such effects are likely also to occur with other QD-based optical probes. (author)

  14. Highly Selective and Sensitive Self-Powered Glucose Sensor Based on Capacitor Circuit.

    Science.gov (United States)

    Slaughter, Gymama; Kulkarni, Tanmay

    2017-05-03

    Enzymatic glucose biosensors are being developed to incorporate nanoscale materials with the biological recognition elements to assist in the rapid and sensitive detection of glucose. Here we present a highly sensitive and selective glucose sensor based on capacitor circuit that is capable of selectively sensing glucose while simultaneously powering a small microelectronic device. Multi-walled carbon nanotubes (MWCNTs) is chemically modified with pyrroloquinoline quinone glucose dehydrogenase (PQQ-GDH) and bilirubin oxidase (BOD) at anode and cathode, respectively, in the biofuel cell arrangement. The input voltage (as low as 0.25 V) from the biofuel cell is converted to a stepped-up power and charged to the capacitor to the voltage of 1.8 V. The frequency of the charge/discharge cycle of the capacitor corresponded to the oxidation of glucose. The biofuel cell structure-based glucose sensor synergizes the advantages of both the glucose biosensor and biofuel cell. In addition, this glucose sensor favored a very high selectivity towards glucose in the presence of competing and non-competing analytes. It exhibited unprecedented sensitivity of 37.66 Hz/mM.cm 2 and a linear range of 1 to 20 mM. This innovative self-powered glucose sensor opens new doors for implementation of biofuel cells and capacitor circuits for medical diagnosis and powering therapeutic devices.

  15. Quality improvement in Vignoles through clonal selection

    Science.gov (United States)

    Our goal is to select an improved, loose-clustered clone of Vignoles that will contribute to an integrated approach to disease control. Clonal selection has historically proven useful in reducing cluster compactness through a variety of mechanisms, including decreased berry size, lengthening of the ...

  16. Epicatechin stimulates mitochondrial activity and selectively sensitizes cancer cells to radiation.

    Directory of Open Access Journals (Sweden)

    Hosam A Elbaz

    Full Text Available Radiotherapy is the treatment of choice for solid tumors including pancreatic cancer, but the effectiveness of treatment is limited by radiation resistance. Resistance to chemotherapy or radiotherapy is associated with reduced mitochondrial respiration and drugs that stimulate mitochondrial respiration may decrease radiation resistance. The objectives of this study were to evaluate the potential of (--epicatechin to stimulate mitochondrial respiration in cancer cells and to selectively sensitize cancer cells to radiation. We investigated the natural compound (--epicatechin for effects on mitochondrial respiration and radiation resistance of pancreatic and glioblastoma cancer cells using a Clark type oxygen electrode, clonogenic survival assays, and Western blot analyses. (--Epicatechin stimulated mitochondrial respiration and oxygen consumption in Panc-1 cells. Human normal fibroblasts were not affected. (--Epicatechin sensitized Panc-1, U87, and MIA PaCa-2 cells with an average radiation enhancement factor (REF of 1.7, 1.5, and 1.2, respectively. (--Epicatechin did not sensitize normal fibroblast cells to ionizing radiation with a REF of 0.9, suggesting cancer cell selectivity. (--Epicatechin enhanced Chk2 phosphorylation and p21 induction when combined with radiation in cancer, but not normal, cells. Taken together, (--epicatechin radiosensitized cancer cells, but not normal cells, and may be a promising candidate for pancreatic cancer treatment when combined with radiation.

  17. Spirulina vesicolor Improves Insulin Sensitivity and Attenuates Hyperglycemia-Mediated Oxidative Stress in Fructose-Fed Rats

    Directory of Open Access Journals (Sweden)

    Walaa Hozayen

    2016-03-01

    Full Text Available Aim: The current study aimed to investigate the anti-hyperglycemic, anti-hyperlipidemic and insulin sensitizing effects of the cyanobacterium Spirulina vesicolor extract in fructose-fed rats. Materials and Methods: Rats were fed 30% fructose solution in drinking water for 4 weeks. Animals exhibited hyperglycemia and hyperinsulinemia were selected for further investigations. Diabetic and control rats were orally supplemented with 50 mg/kg body weight S. vesicolor extract for 4 weeks. Results: At the end of 8 weeks, fructose-fed rats showed significant increase in serum glucose, insulin, cholesterol, triglycerides, cardiovascular risk indices and insulin resistance. Treatment of the fructose-fed rats with S. vesicolor extract improved this metabolic profile. Fructose feeding produced a significant increase in serum tumor necrosis factor alpha (TNF-α and a decrease in adiponectin levels. In addition, fructose-fed rats exhibited a significant increase in liver, kidney and heart lipid peroxidation levels, and declined antioxidant defenses. Supplementation of the fructose-fed rats with S. vesicolor extract reversed these alterations. Conclusion: S. vesicolor attenuates hyperglycemia-mediated oxidative stress and inflammation, and is thus effective in improving insulin sensitivity in fructose-fed rats. [J Complement Med Res 2016; 5(1.000: 57-64

  18. Illustrating sensitivity in environmental fate models using partitioning maps - application to selected contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, T.; Wania, F. [Univ. of Toronto at Scarborough - DPES, Toronto (Canada)

    2004-09-15

    Generic environmental multimedia fate models are important tools in the assessment of the impact of organic pollutants. Because of limited possibilities to evaluate generic models by comparison with measured data and the increasing regulatory use of such models, uncertainties of model input and output are of considerable concern. This led to a demand for sensitivity and uncertainty analyses for the outputs of environmental fate models. Usually, variations of model predictions of the environmental fate of organic contaminants are analyzed for only one or at most a few selected chemicals, even though parameter sensitivity and contribution to uncertainty are widely different for different chemicals. We recently presented a graphical method that allows for the comprehensive investigation of model sensitivity and uncertainty for all neutral organic chemicals simultaneously. This is achieved by defining a two-dimensional hypothetical ''chemical space'' as a function of the equilibrium partition coefficients between air, water, and octanol (K{sub OW}, K{sub AW}, K{sub OA}), and plotting sensitivity and/or uncertainty of a specific model result to each input parameter as function of this chemical space. Here we show how such sensitivity maps can be used to quickly identify the variables with the highest influence on the environmental fate of selected, chlorobenzenes, polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), hexachlorocyclohexanes (HCHs) and brominated flame retardents (BFRs).

  19. IMRT QA: Selecting gamma criteria based on error detection sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Steers, Jennifer M. [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 and Physics and Biology in Medicine IDP, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095 (United States); Fraass, Benedick A., E-mail: benedick.fraass@cshs.org [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 (United States)

    2016-04-15

    Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose

  20. One week treatment with the IL-1 receptor antagonist anakinra leads to a sustained improvement in insulin sensitivity in insulin resistant patients with type 1 diabetes mellitus.

    Science.gov (United States)

    van Asseldonk, Edwin J P; van Poppel, Pleun C M; Ballak, Dov B; Stienstra, Rinke; Netea, Mihai G; Tack, Cees J

    2015-10-01

    Inflammation associated with obesity is involved in the development of insulin resistance. We hypothesized that anti-inflammatory treatment with the Interleukin-1 receptor antagonist anakinra would improve insulin sensitivity. In an open label proof-of-concept study, we included overweight patients diagnosed with type 1 diabetes with an HbA1c level over 7.5%. Selecting insulin resistant patients with longstanding type 1 diabetes allowed us to study the effects of anakinra on insulin sensitivity. Patients were treated with 100mg anakinra daily for one week. Insulin sensitivity, insulin need and blood glucose profiles were measured before, after one week and after four weeks of follow-up. Fourteen patients completed the study. One week of anakinra treatment led to an improvement of insulin sensitivity, an effect that was sustained for four weeks. Similarly, glucose profiles, HbA1c levels and insulin needs improved. In conclusion, one week of treatment with anakinra improves insulin sensitivity in patients with type 1 diabetes. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Improved Extreme Learning Machine based on the Sensitivity Analysis

    Science.gov (United States)

    Cui, Licheng; Zhai, Huawei; Wang, Benchao; Qu, Zengtang

    2018-03-01

    Extreme learning machine and its improved ones is weak in some points, such as computing complex, learning error and so on. After deeply analyzing, referencing the importance of hidden nodes in SVM, an novel analyzing method of the sensitivity is proposed which meets people’s cognitive habits. Based on these, an improved ELM is proposed, it could remove hidden nodes before meeting the learning error, and it can efficiently manage the number of hidden nodes, so as to improve the its performance. After comparing tests, it is better in learning time, accuracy and so on.

  2. Improved Sensitivity Relations in State Constrained Optimal Control

    International Nuclear Information System (INIS)

    Bettiol, Piernicola; Frankowska, Hélène; Vinter, Richard B.

    2015-01-01

    Sensitivity relations in optimal control provide an interpretation of the costate trajectory and the Hamiltonian, evaluated along an optimal trajectory, in terms of gradients of the value function. While sensitivity relations are a straightforward consequence of standard transversality conditions for state constraint free optimal control problems formulated in terms of control-dependent differential equations with smooth data, their verification for problems with either pathwise state constraints, nonsmooth data, or for problems where the dynamic constraint takes the form of a differential inclusion, requires careful analysis. In this paper we establish validity of both ‘full’ and ‘partial’ sensitivity relations for an adjoint state of the maximum principle, for optimal control problems with pathwise state constraints, where the underlying control system is described by a differential inclusion. The partial sensitivity relation interprets the costate in terms of partial Clarke subgradients of the value function with respect to the state variable, while the full sensitivity relation interprets the couple, comprising the costate and Hamiltonian, as the Clarke subgradient of the value function with respect to both time and state variables. These relations are distinct because, for nonsmooth data, the partial Clarke subdifferential does not coincide with the projection of the (full) Clarke subdifferential on the relevant coordinate space. We show for the first time (even for problems without state constraints) that a costate trajectory can be chosen to satisfy the partial and full sensitivity relations simultaneously. The partial sensitivity relation in this paper is new for state constraint problems, while the full sensitivity relation improves on earlier results in the literature (for optimal control problems formulated in terms of Lipschitz continuous multifunctions), because a less restrictive inward pointing hypothesis is invoked in the proof, and because

  3. A sensitive and selective chemiluminescence sensor for the determination of dopamine based on silanized magnetic graphene oxide-molecularly imprinted polymer.

    Science.gov (United States)

    Duan, Huimin; Li, Leilei; Wang, Xiaojiao; Wang, Yanhui; Li, Jianbo; Luo, Chuannan

    2015-03-15

    Based on silanized magnetic graphene oxide-molecularly imprinted polymer (Si-MG-MIP), a sensitive and selective chemiluminescence sensor for dopamine measurement was developed. Si-MG-MIP, in which silanes was introduced to improve the mass transfer, graphene oxide was employed to improve absorption capacity, Fe3O4 nanoparticles were applied for separation easily and molecularly imprinted polymer was used to improve selectivity, demonstrated the advantages of the sensor. All the composites were confirmed by SEM, TEM, XRD and FTIR. Under the optimal conditions of chemiluminescence, dopamine could be assayed in the range of 8.0-200.0 ng/mL with a correlation coefficient of linear regression of 0.9970. The detection limit was 1.5 ng/mL (3δ) and the precision for 11 replicate detections of 80.0 ng/mL dopamine was 3.4% (RSD). When the sensor was applied in determining dopamine in actual samples, recovery ranged from 94% to 110%, which revealed that the results were satisfactory. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. A Hypothesis and Review of the Relationship between Selection for Improved Production Efficiency, Coping Behavior, and Domestication

    Directory of Open Access Journals (Sweden)

    Wendy M. Rauw

    2017-09-01

    Full Text Available Coping styles in response to stressors have been described both in humans and in other animal species. Because coping styles are directly related to individual fitness they are part of the life history strategy. Behavioral styles trade off with other life-history traits through the acquisition and allocation of resources. Domestication and subsequent artificial selection for production traits specifically focused on selection of individuals with energy sparing mechanisms for non-production traits. Domestication resulted in animals with low levels of aggression and activity, and a low hypothalamic–pituitary–adrenal (HPA axis reactivity. In the present work, we propose that, vice versa, selection for improved production efficiency may to some extent continue to favor docile domesticated phenotypes. It is hypothesized that both domestication and selection for improved production efficiency may result in the selection of reactive style animals. Both domesticated and reactive style animals are characterized by low levels of aggression and activity, and increased serotonin neurotransmitter levels. However, whereas domestication quite consistently results in a decrease in the functional state of the HPA axis, the reactive coping style is often found to be dominated by a high HPA response. This may suggest that fearfulness and coping behavior are two independent underlying dimensions to the coping response. Although it is generally proposed that animal welfare improves with selection for calmer animals that are less fearful and reactive to novelty, animals bred to be less sensitive with fewer desires may be undesirable from an ethical point of view.

  5. Hierarchical Nanogold Labels to Improve the Sensitivity of Lateral Flow Immunoassay

    Science.gov (United States)

    Serebrennikova, Kseniya; Samsonova, Jeanne; Osipov, Alexander

    2018-06-01

    Lateral flow immunoassay (LFIA) is a widely used express method and offers advantages such as a short analysis time, simplicity of testing and result evaluation. However, an LFIA based on gold nanospheres lacks the desired sensitivity, thereby limiting its wide applications. In this study, spherical nanogold labels along with new types of nanogold labels such as gold nanopopcorns and nanostars were prepared, characterized, and applied for LFIA of model protein antigen procalcitonin. It was found that the label with a structure close to spherical provided more uniform distribution of specific antibodies on its surface, indicative of its suitability for this type of analysis. LFIA using gold nanopopcorns as a label allowed procalcitonin detection over a linear range of 0.5-10 ng mL-1 with the limit of detection of 0.1 ng mL-1, which was fivefold higher than the sensitivity of the assay with gold nanospheres. Another approach to improve the sensitivity of the assay included the silver enhancement method, which was used to compare the amplification of LFIA for procalcitonin detection. The sensitivity of procalcitonin determination by this method was 10 times better the sensitivity of the conventional LFIA with gold nanosphere as a label. The proposed approach of LFIA based on gold nanopopcorns improved the detection sensitivity without additional steps and prevented the increased consumption of specific reagents (antibodies).

  6. Factors to Consider in Selecting an Organisational Improvement Initiative: Survey Results

    Directory of Open Access Journals (Sweden)

    Mohammad Musli

    2017-01-01

    Full Text Available Organisations should select the appropriate improvement initiative that will fit with the context of organisation and provide value to the organisation. This paper presents 18 factors to be considered when selecting an organisational improvement initiative. Organisational improvement initiatives are approaches, management systems, tools and/or techniques that can be used for managing and improving organisations, such as Lean, ISO9001, Six Sigma and Improvement Team. A survey was conducted to identify the level of importance of these 18 factors as criteria for selecting an improvement initiative. Purposive sampling was used for this survey involving practitioners, managers, engineers, executives, consultants and/or academicians, who have been involved in the selection and/or implementation of organisational improvement initiatives in Malaysia. Two factors were rated as ‘very high importance’, which involve: (1 The ability to gain top management commitment and support to introduce and implement the initiative successfully, and (2 The initiative is aligned to the vision, mission and/or purpose of the organisation. All these factors can be adopted by the organisations as decision criteria to assist in the selection of the most appropriate improvement initiative based on rational decision making.

  7. Sensitivity of selected landscape pattern metrics to land-cover misclassification and differences in land-cover composition

    Science.gov (United States)

    James D. Wickham; Robert V. O' Neill; Kurt H. Riitters; Timothy G. Wade; K. Bruce Jones

    1997-01-01

    Calculation of landscape metrics from land-cover data is becoming increasingly common. Some studies have shown that these measurements are sensitive to differences in land-cover composition, but none are known to have tested also their a sensitivity to land-cover misclassification. An error simulation model was written to test the sensitivity of selected land-scape...

  8. Investigation of sensitivity and selectivity of ZnO thin film to volatile organic compounds

    Science.gov (United States)

    Teimoori, F.; Khojier, K.; Dehnavi, N. Z.

    2017-06-01

    This research addresses a detailed study on the sensitivity and selectivity of ZnO thin film to volatile organic compound (VOC) vapors that can be used for the development of VOC sensors. The ZnO thin film of 100 nm thickness was prepared by post-annealing of e-beam evaporated Zn thin film. The sample was structurally, morphologically, and chemically characterized by X-ray diffraction and field emission scanning electron microscopy analyses. The sensitivity, selectivity, and detection limit of the sample were tested with respect to a wide range of common VOC vapors, including acetone, formaldehyde, acetic acid, formic acid, acetylene, toluene, benzene, ethanol, methanol, and isopropanol in the temperature range of 200-400 °C. The results show that the best sensitivity and detection limit of the sample are related to acetone vapor in the studied temperature range. The ZnO thin film-based acetone sensor also shows a good reproducibility and stability at the operating temperature of 280 °C.

  9. Harmonic detection of magnetic resonance for sensitivity improvement of optical atomic magnetometers

    Energy Technology Data Exchange (ETDEWEB)

    Ranjbaran, M. [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Tehranchi, M.M., E-mail: teranchi@sbu.ac.ir [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Physics Department, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Hamidi, S.M. [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Khalkhali, S.M.H. [Physics Department, Kharazmi University, Tehran (Iran, Islamic Republic of)

    2017-02-15

    Highly sensitive atomic magnetometers use optically detected magnetic resonance of atomic spins to measure extremely weak magnetic field changes. The magnetometer sensitivity is directly proportional to the ratio of intensity to line-shape of the resonance signal. To obtain narrower resonance signal, we implemented harmonic detection of magnetic resonance method in M{sub x} configuration. The nonlinear spin polarization dynamics in detection of the higher harmonics were employed in phenomenological Bloch equations. The measured and simulated harmonic components of the resonance signals in frequency domain yielded significantly narrower line-width accompanying much improved sensitivity. Our results confirm the sensitivity improvement by a factor of two in optical atomic magnetometer via second harmonic signal which can open a new insight in the weak magnetic field measurement system design. - Highlights: • Highly sensitive atomic magnetometers have been used to measure weak magentic filed. • To obtain narrower resonance signal, we impalnted harmonic detection of magnetic resonance. • The nonlinear spin polarization dynamics in detetion of the higher harmonics were imployed.

  10. Mirnacle: machine learning with SMOTE and random forest for improving selectivity in pre-miRNA ab initio prediction.

    Science.gov (United States)

    Marques, Yuri Bento; de Paiva Oliveira, Alcione; Ribeiro Vasconcelos, Ana Tereza; Cerqueira, Fabio Ribeiro

    2016-12-15

    MicroRNAs (miRNAs) are key gene expression regulators in plants and animals. Therefore, miRNAs are involved in several biological processes, making the study of these molecules one of the most relevant topics of molecular biology nowadays. However, characterizing miRNAs in vivo is still a complex task. As a consequence, in silico methods have been developed to predict miRNA loci. A common ab initio strategy to find miRNAs in genomic data is to search for sequences that can fold into the typical hairpin structure of miRNA precursors (pre-miRNAs). The current ab initio approaches, however, have selectivity issues, i.e., a high number of false positives is reported, which can lead to laborious and costly attempts to provide biological validation. This study presents an extension of the ab initio method miRNAFold, with the aim of improving selectivity through machine learning techniques, namely, random forest combined with the SMOTE procedure that copes with imbalance datasets. By comparing our method, termed Mirnacle, with other important approaches in the literature, we demonstrate that Mirnacle substantially improves selectivity without compromising sensitivity. For the three datasets used in our experiments, our method achieved at least 97% of sensitivity and could deliver a two-fold, 20-fold, and 6-fold increase in selectivity, respectively, compared with the best results of current computational tools. The extension of miRNAFold by the introduction of machine learning techniques, significantly increases selectivity in pre-miRNA ab initio prediction, which optimally contributes to advanced studies on miRNAs, as the need of biological validations is diminished. Hopefully, new research, such as studies of severe diseases caused by miRNA malfunction, will benefit from the proposed computational tool.

  11. Validation and sensitivity tests on improved parametrizations of a land surface process model (LSPM) in the Po Valley

    International Nuclear Information System (INIS)

    Cassardo, C.; Carena, E.; Longhetto, A.

    1998-01-01

    The Land Surface Process Model (LSPM) has been improved with respect to the 1. version of 1994. The modifications have involved the parametrizations of the radiation terms and of turbulent heat fluxes. A parametrization of runoff has also been developed, in order to close the hydrologic balance. This 2. version of LSPM has been validated against experimental data gathered at Mottarone (Verbania, Northern Italy) during a field experiment. The results of this validation show that this new version is able to apportionate the energy into sensible and latent heat fluxes. LSPM has also been submitted to a series of sensitivity tests in order to investigate the hydrological part of the model. The physical quantities selected in these sensitivity experiments have been the initial soil moisture content and the rainfall intensity. In each experiment, the model has been forced by using the observations carried out at the synoptic stations of San Pietro Capofiume (Po Valley, Italy). The observed characteristics of soil and vegetation (not involved in the sensitivity tests) have been used as initial and boundary conditions. The results of the simulation show that LSPM can reproduce well the energy, heat and water budgets and their behaviours with varying the selected parameters. A careful analysis of the LSPM output shows also the importance to identify the effective soil type

  12. Highly selective and sensitive detection of neurotransmitters using receptor-modified single-walled carbon nanotube sensors

    Science.gov (United States)

    Kim, Byeongju; Song, Hyun Seok; Jin, Hye Jun; Park, Eun Jin; Lee, Sang Hun; Lee, Byung Yang; Park, Tai Hyun; Hong, Seunghun

    2013-07-01

    We present receptor-modified carbon nanotube sensors for the highly selective and sensitive detection of acetylcholine (ACh), one kind of neurotransmitter. Here, we successfully expressed the M1 muscarinic acetylcholine receptor (M1 mAChR), a family of G protein-coupled receptors (GPCRs), in E. coli and coated single-walled carbon nanotube (swCNT)-field effect transistors (FETs) with lipid membrane including the receptor, enabling highly selective and sensitive ACh detection. Using this sensor, we could detect ACh at 100 pM concentration. Moreover, we showed that this sensor could selectively detect ACh among other neurotransmitters. This is the first demonstration of the real-time detection of ACh using specific binding between ACh and M1 mAChR, and it may lead to breakthroughs for various applications such as disease diagnosis and drug screening.

  13. Highly selective and sensitive detection of neurotransmitters using receptor-modified single-walled carbon nanotube sensors

    International Nuclear Information System (INIS)

    Kim, Byeongju; Jin, Hye Jun; Park, Eun Jin; Hong, Seunghun; Song, Hyun Seok; Lee, Sang Hun; Park, Tai Hyun; Lee, Byung Yang

    2013-01-01

    We present receptor-modified carbon nanotube sensors for the highly selective and sensitive detection of acetylcholine (ACh), one kind of neurotransmitter. Here, we successfully expressed the M1 muscarinic acetylcholine receptor (M1 mAChR), a family of G protein-coupled receptors (GPCRs), in E. coli and coated single-walled carbon nanotube (swCNT)-field effect transistors (FETs) with lipid membrane including the receptor, enabling highly selective and sensitive ACh detection. Using this sensor, we could detect ACh at 100 pM concentration. Moreover, we showed that this sensor could selectively detect ACh among other neurotransmitters. This is the first demonstration of the real-time detection of ACh using specific binding between ACh and M1 mAChR, and it may lead to breakthroughs for various applications such as disease diagnosis and drug screening. (paper)

  14. Selective sensitivity in Kerr microscopy.

    Science.gov (United States)

    Soldatov, I V; Schäfer, R

    2017-07-01

    A new technique for contrast separation in wide-field magneto-optical Kerr microscopy is introduced. Utilizing the light from eight light emitting diodes, guided to the microscope by glass fibers and being switched synchronously with the camera exposure, domain images with orthogonal in-plane sensitivity can be displayed simultaneously at real-time, and images with pure in-plane or polar contrast can be obtained. The benefit of this new method of contrast separation is demonstrated for Permalloy films, a NdFeB sinter magnet, and a cobalt crystal. Moreover, the new technique is shown to strongly enhance the sensitivity of Kerr microscopy by eliminating parasitic contrast contributions occurring in conventional setups. A doubling of the in-plane domain contrast and a sensitivity to Kerr rotations as low as 0.6 mdeg is demonstrated.

  15. Selective sensitivity in Kerr microscopy

    Science.gov (United States)

    Soldatov, I. V.; Schäfer, R.

    2017-07-01

    A new technique for contrast separation in wide-field magneto-optical Kerr microscopy is introduced. Utilizing the light from eight light emitting diodes, guided to the microscope by glass fibers and being switched synchronously with the camera exposure, domain images with orthogonal in-plane sensitivity can be displayed simultaneously at real-time, and images with pure in-plane or polar contrast can be obtained. The benefit of this new method of contrast separation is demonstrated for Permalloy films, a NdFeB sinter magnet, and a cobalt crystal. Moreover, the new technique is shown to strongly enhance the sensitivity of Kerr microscopy by eliminating parasitic contrast contributions occurring in conventional setups. A doubling of the in-plane domain contrast and a sensitivity to Kerr rotations as low as 0.6 mdeg is demonstrated.

  16. On the Exploitation of Sensitivity Derivatives for Improving Sampling Methods

    Science.gov (United States)

    Cao, Yanzhao; Hussaini, M. Yousuff; Zang, Thomas A.

    2003-01-01

    Many application codes, such as finite-element structural analyses and computational fluid dynamics codes, are capable of producing many sensitivity derivatives at a small fraction of the cost of the underlying analysis. This paper describes a simple variance reduction method that exploits such inexpensive sensitivity derivatives to increase the accuracy of sampling methods. Three examples, including a finite-element structural analysis of an aircraft wing, are provided that illustrate an order of magnitude improvement in accuracy for both Monte Carlo and stratified sampling schemes.

  17. Mesoporous carbon nitride based biosensor for highly sensitive and selective analysis of phenol and catechol in compost bioremediation.

    Science.gov (United States)

    Zhou, Yaoyu; Tang, Lin; Zeng, Guangming; Chen, Jun; Cai, Ye; Zhang, Yi; Yang, Guide; Liu, Yuanyuan; Zhang, Chen; Tang, Wangwang

    2014-11-15

    Herein, we reported here a promising biosensor by taking advantage of the unique ordered mesoporous carbon nitride material (MCN) to convert the recognition information into a detectable signal with enzyme firstly, which could realize the sensitive, especially, selective detection of catechol and phenol in compost bioremediation samples. The mechanism including the MCN based on electrochemical, biosensor assembly, enzyme immobilization, and enzyme kinetics (elucidating the lower detection limit, different linear range and sensitivity) was discussed in detail. Under optimal conditions, GCE/MCN/Tyr biosensor was evaluated by chronoamperometry measurements and the reduction current of phenol and catechol was proportional to their concentration in the range of 5.00 × 10(-8)-9.50 × 10(-6)M and 5.00 × 10(-8)-1.25 × 10(-5)M with a correlation coefficient of 0.9991 and 0.9881, respectively. The detection limits of catechol and phenol were 10.24 nM and 15.00 nM (S/N=3), respectively. Besides, the data obtained from interference experiments indicated that the biosensor had good specificity. All the results showed that this material is suitable for load enzyme and applied to the biosensor due to the proposed biosensor exhibited improved analytical performances in terms of the detection limit and specificity, provided a powerful tool for rapid, sensitive, especially, selective monitoring of catechol and phenol simultaneously. Moreover, the obtained results may open the way to other MCN-enzyme applications in the environmental field. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Importance of self-shielding for improving sensitivity coefficients in light water nuclear reactors

    International Nuclear Information System (INIS)

    Foad, Basma; Takeda, Toshikazu

    2014-01-01

    Highlights: • A new method has been developed for calculating sensitivity coefficients. • This method is based on the use of infinite dilution cross-sections instead of effective cross-sections. • The change of self-shielding factor due to cross-section perturbation has been considered. • SRAC and SAINT codes are used for calculating improved sensitivities, while MCNP code has been used for verification. - Abstract: In order to perform sensitivity analyzes in light water reactors where self-shielding effect becomes important, a new method has been developed for calculating sensitivity coefficient of core characteristics relative to the infinite dilution cross-sections instead of the effective cross-sections. This method considers the change of the self-shielding factor due to cross-section perturbation for different nuclides and reactions. SRAC and SAINT codes are used to calculate the improved sensitivity; while the accuracy of the present method has been verified by MCNP code and good agreement has been found

  19. Sensitivity of the improved Dutch tube diffusion test for detection of ...

    African Journals Online (AJOL)

    The sensitivity of the improved two-tube test for detection of antimicrobial residues in Kenyan milk was investigated by comparison with the commercial Delvo test SP. Suspect positive milk samples (n =244) from five milk collection centers, were analyzed with the improved two-tube and the commercial Delvo SP test as per ...

  20. Perceptual load manipulation reveals sensitivity of the face-selective N170 to attention.

    Science.gov (United States)

    Mohamed, Tarik N; Neumann, Markus F; Schweinberger, Stefan R

    2009-05-27

    It has been controversial whether the face-sensitive N170 is affected by selective attention. We manipulated attention sensu Lavie's perceptual load theory to short (200 ms) presentations of task-irrelevant unfamiliar faces or houses, while participants identified superimposed target letters 'X' versus 'N'. These targets were strings of either six identical (low load) or six different letters (high load). Under low load, we found a prominent face-selective N170 response. Under high load, however, we not only observed a dramatic reduction of the face N170 but also an unexpected enhancement of the house N170, such that face selectivity was almost completely lost. We conclude that the early stages of face processing indexed by the N170 strongly depend on selective attention.

  1. Chromatographic air analyser microsystem for the selective and sensitive detection of atmospheric pollutants

    International Nuclear Information System (INIS)

    Sanchez, Jean-Baptiste; Lahlou, Houda; Mohsen, Yehya; Berger, Franck; Vilanova, Xavier; Correig, Xavier

    2011-01-01

    The development of industry and automotive trafic produces Volatile Organic Compounds (VOCs) whose toxicity can affect seriously human health and environment. The level of those contaminants in air must be as low as possible. In this context, there is a need for in situ systems that could monitor selectively the concentration of these compounds. The aim of this study is to demonstrate the efficiency of a system build with a pre-concentrator, a chromatographic micro-column and a tin oxide-based gas sensor for the selective and sensitive detection of atmospheric pollutants. In particular, this study is focused on the selective detection of benzene and 1,3 butadiene.

  2. Research for improved flexible tactile sensor sensitivity

    International Nuclear Information System (INIS)

    Yun, Hae Yong; Kim, Ho Chan; Lee, In Hwan

    2015-01-01

    With the development of robotic technologies, in recent years these technologies have been applied to multidisciplinary fields of study. To operate similarly to a human being, many robot technologies require devices that can receive exterior stimulus, temperature, visual data, and the sense of smell, etc. The robot's hand needs sensor devices that can receive exterior stimuli in order to operate similarly to human skin. The flexible tactile sensor for the robot has to be manufactured to have a shape similar to the shape of human skin. The research studied the development of a system and materials that will enable exterior stimuli to be received effectively. This research used carbon nano tube as a material. Carbon nano tube is used because it has a high electrical conductivity and outstanding mechanical characteristics. In addition, the two composite Materials are used to improve the stimulation sensitivity at different rates, the flexible tactile sensor to measure the sensitivity. Using 3D printing technology, the fabrication of a flexible tactile sensor system is introduced.

  3. Research for improved flexible tactile sensor sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Hae Yong; Kim, Ho Chan [Andong National University, Andong (Korea, Republic of); Lee, In Hwan [Chungbuk National University, Chungju (Korea, Republic of)

    2015-11-15

    With the development of robotic technologies, in recent years these technologies have been applied to multidisciplinary fields of study. To operate similarly to a human being, many robot technologies require devices that can receive exterior stimulus, temperature, visual data, and the sense of smell, etc. The robot's hand needs sensor devices that can receive exterior stimuli in order to operate similarly to human skin. The flexible tactile sensor for the robot has to be manufactured to have a shape similar to the shape of human skin. The research studied the development of a system and materials that will enable exterior stimuli to be received effectively. This research used carbon nano tube as a material. Carbon nano tube is used because it has a high electrical conductivity and outstanding mechanical characteristics. In addition, the two composite Materials are used to improve the stimulation sensitivity at different rates, the flexible tactile sensor to measure the sensitivity. Using 3D printing technology, the fabrication of a flexible tactile sensor system is introduced.

  4. Improving Genetic Gain with Genomic Selection in Autotetraploid Potato

    Directory of Open Access Journals (Sweden)

    Anthony T. Slater

    2016-11-01

    Full Text Available Potato ( L. breeders consider a large number of traits during cultivar development and progress in conventional breeding can be slow. There is accumulating evidence that some of these traits, such as yield, are affected by a large number of genes with small individual effects. Recently, significant efforts have been applied to the development of genomic resources to improve potato breeding, culminating in a draft genome sequence and the identification of a large number of single nucleotide polymorphisms (SNPs. The availability of these genome-wide SNPs is a prerequisite for implementing genomic selection for improvement of polygenic traits such as yield. In this review, we investigate opportunities for the application of genomic selection to potato, including novel breeding program designs. We have considered a number of factors that will influence this process, including the autotetraploid and heterozygous genetic nature of potato, the rate of decay of linkage disequilibrium, the number of required markers, the design of a reference population, and trait heritability. Based on estimates of the effective population size derived from a potato breeding program, we have calculated the expected accuracy of genomic selection for four key traits of varying heritability and propose that it will be reasonably accurate. We compared the expected genetic gain from genomic selection with the expected gain from phenotypic and pedigree selection, and found that genetic gain can be substantially improved by using genomic selection.

  5. Quasi physisorptive two dimensional tungsten oxide nanosheets with extraordinary sensitivity and selectivity to NO2.

    Science.gov (United States)

    Khan, Hareem; Zavabeti, Ali; Wang, Yichao; Harrison, Christopher J; Carey, Benjamin J; Mohiuddin, Md; Chrimes, Adam F; De Castro, Isabela Alves; Zhang, Bao Yue; Sabri, Ylias M; Bhargava, Suresh K; Ou, Jian Zhen; Daeneke, Torben; Russo, Salvy P; Li, Yongxiang; Kalantar-Zadeh, Kourosh

    2017-12-14

    Attributing to their distinct thickness and surface dependent physicochemical properties, two dimensional (2D) nanostructures have become an area of increasing interest for interfacial interactions. Effectively, properties such as high surface-to-volume ratio, modulated surface activities and increased control of oxygen vacancies make these types of materials particularly suitable for gas-sensing applications. This work reports a facile wet-chemical synthesis of 2D tungsten oxide nanosheets by sonication of tungsten particles in an acidic environment and thermal annealing thereafter. The resultant product of large nanosheets with intrinsic substoichiometric properties is shown to be highly sensitive and selective to nitrogen dioxide (NO 2 ) gas, which is a major pollutant. The strong synergy between polar NO 2 molecules and tungsten oxide surface and also abundance of active surface sites on the nanosheets for molecule interactions contribute to the exceptionally sensitive and selective response. An extraordinary response factor of ∼30 is demonstrated to ultralow 40 parts per billion (ppb) NO 2 at a relatively low operating temperature of 150 °C, within the physisorption temperature band for tungsten oxide. Selectivity to NO 2 is demonstrated and the theory behind it is discussed. The structural, morphological and compositional characteristics of the synthesised and annealed materials are extensively characterised and electronic band structures are proposed. The demonstrated 2D tungsten oxide based sensing device holds the greatest promise for producing future commercial low-cost, sensitive and selective NO 2 gas sensors.

  6. Improvement in Sensitivity of an Inductive Oil Palm Fruit Sensor

    Directory of Open Access Journals (Sweden)

    Norhisam Misron

    2014-02-01

    Full Text Available Among palm oil millers, the ripeness of oil palm Fresh Fruit Bunch (FFB is determined through visual inspection. To increase the productivity of the millers, many researchers have proposed with a new detection method to replace the conventional one. The sensitivity of such a sensor plays a crucial role in determining the effectiveness of the method. In our preliminary study a novel oil palm fruit sensor to detect the maturity of oil palm fruit bunches is proposed. The design of the proposed air coil sensor based on an inductive sensor is further investigated to improve its sensitivity. This paper investigates the results pertaining to the effects of the air coil structure of an oil palm fruit sensor, taking consideration of the used copper wire diameter ranging from 0.10 mm to 0.18 mm with 60 turns. The flat-type shape of air coil was used on twenty samples of fruitlets from two categories, namely ripe and unripe. Samples are tested with frequencies ranging from 20 Hz to 120 MHz. The sensitivity of the sensor between air to fruitlet samples increases as the coil diameter increases. As for the sensitivity differences between ripe and unripe samples, the 5 mm air coil length with the 0.12 mm coil diameter provides the highest percentage difference between samples and it is amongst the highest deviation value between samples. The result from this study is important to improve the sensitivity of the inductive oil palm fruit sensor mainly with regards to the design of the air coil structure. The efficiency of the sensor to determine the maturity of the oil palm FFB and the ripening process of the fruitlet could further be enhanced.

  7. A highly sensitive and selective fluorescent sensor for detection of sulfide anion based on the steric hindrance effect

    Science.gov (United States)

    Chen, Guanfan; Tang, Mengzhuo; Fu, Xiufang; Cheng, Fenmin; Zou, Xianghua; Wang, Jingpei; Zeng, Rongjin

    2018-01-01

    Sulfide anions are not only generated as a byproduct from industrial processes but also as a crucial kind of element in biological systems. Therefore, fluorescent probes for detecting sulfide anion with sensitive and selective characters are highly popular. In this study, we report a highly sensitive and selective fluorescent sensor M1 for detection of sulfide anion based on the steric hindrance effect, where the recognition unit, dinitrobenzenesulfonate ester group is linked to aromatic ortho-position in the porphyrin, and correspondingly the fluorescence of fluorescein is efficiently quenched. Compared with the sensors with recognition unit linked to the other aromatic positions, the fluorescent sensor M1 has a lower fluorescence background. Furthermore, the corresponding fluorescence responses (F/F0) of M1 for mercapto amino-acid GSH, Hcy and Cys, were all far lower than the relative fluorescence ratio F/F0 values for S2-. It means that M1 is sensitive and selective to detection of S2-, and has an anti-disturbance ability to the biologically-relevant thiols, GSH, Hcy and Cys, and has the prospect of application in the exact detection of sulfide anions in living organisms. This approach offers some useful insights for realizing sensitive and selective fluorescent turn-on sensing in the detection assays for other analytes.

  8. Surrogate indicators of sensitivity in gynecologic cytology: Can they be used to improve the measurement of sensitivity in the laboratory?

    Directory of Open Access Journals (Sweden)

    Renshaw Andrew

    2009-01-01

    Full Text Available Background: Measuring the sensitivity of screening in gynecologic cytology in real life is problematic. However, other quality measures may correlate with sensitivity, including the atypical squamous cells (ASC/squamous intraepithelial lesion (SIL ratio. Whether these other measures can function as "surrogate indicators" for sensitivity and improve the assessment of sensitivity in the laboratory is not known. Materials and Methods: We compared multiple quality measures with true screening sensitivity in a variety of situations. Results: The abnormal rate, ASC rate, and ASC/SIL ratio were all highly correlated (r = .83 or greater with sensitivity when the overall laboratory sensitivity was low (85% but became less correlated (.64 or less or uncorrelated when the screening sensitivity was higher (88% or 95%, respectively. Sensitivity was more highly correlated with the abnormal rate than the ASC/SIL ratio at low screening sensitivity. While thresholds could be set that were highly sensitive and specific for suboptimal screening, these thresholds were often less than one standard deviation away from the mean. Conclusion: The correlation of the abnormal rate and the ASC/SIL ratio with sensitivity depends on overall sensitivity. Standards to define minimum screening sensitivity can be defined, but these standards are relatively narrow. These features may limit the utility of these quality measures as surrogates for sensitivity.

  9. Parametric Sensitivity Analysis of the WAVEWATCH III Model

    Directory of Open Access Journals (Sweden)

    Beng-Chun Lee

    2009-01-01

    Full Text Available The parameters in numerical wave models need to be calibrated be fore a model can be applied to a specific region. In this study, we selected the 8 most important parameters from the source term of the WAVEWATCH III model and subjected them to sensitivity analysis to evaluate the sensitivity of the WAVEWATCH III model to the selected parameters to determine how many of these parameters should be considered for further discussion, and to justify the significance priority of each parameter. After ranking each parameter by sensitivity and assessing their cumulative impact, we adopted the ARS method to search for the optimal values of those parameters to which the WAVEWATCH III model is most sensitive by comparing modeling results with ob served data at two data buoys off the coast of north eastern Taiwan; the goal being to find optimal parameter values for improved modeling of wave development. The procedure adopting optimal parameters in wave simulations did improve the accuracy of the WAVEWATCH III model in comparison to default runs based on field observations at two buoys.

  10. Role of Dyestuff in Improving Dye-Sensitized Solar Cell Performance

    Directory of Open Access Journals (Sweden)

    Yehia Selim

    2017-03-01

    Full Text Available Dye-sensitized solar cells DSSCs have attracted great attention for their simple fabrication process, low production costs, relatively high conversion efficiency, and being environmental friendly.DSSC are a combination of materials, consisting of a transparent electrode coated with a dye-sensitized mesoporous film of nanocrystalline particles of TiO2, an electrolyte containing a suitable redox-couple and a electrode.DSSCs use organic dye assist to produce electricity in a wide range of light conditions, indoors and outdoors.The dye in the solar cell is the key element since it is responsible for light harvesting ability, photoelectron generation (the creation of free charges after injection of electrons into the nanostructured semi-conducting oxide and electron transfer.For this reason, this paper gives a background of dyestuff, types and limitations. The motivation of this work is to design a simple, easy and prepare an efficient organic dye sensitizer.Also, this paper investigates the important criteria which are considered for selecting dye to enhance DSSC efficiency. 

  11. Electrochemical sensor based on a carbon nanotube-modified imprinted sol–gel for selective and sensitive determination of β2-agonists

    International Nuclear Information System (INIS)

    Xu, Wei; Liu, Ping; Guo, Chunhui; Dong, Chao; Zhang, Xiuhua; Wang, Shengfu

    2013-01-01

    We describe a molecularly imprinted electrochemical sensor for selective and sensitive determination of β2-agonists. It is making use of a combination of single-wall carbon nanotubes (SWNTs) with a molecularly imprinted sol–gel. The SWNTs were introduced in order to enhance electron transport and sensitivity. The imprinted sol–gel film with its specific binding sites acts as a selective recognition element and as a preconcentrator for β 2 -agonists. The morphology of the imprinted film was characterized by scanning electron microscopy. The optimized sensor displays high sensitivity and excellent selectivity for the β 2 -agonists as shown for their determination in human serum samples. (author)

  12. High intensity interval training improves liver and adipose tissue insulin sensitivity

    Directory of Open Access Journals (Sweden)

    Katarina Marcinko

    2015-12-01

    Conclusions: These data indicate that HIIT lowers blood glucose levels by improving adipose and liver insulin sensitivity independently of changes in adiposity, adipose tissue inflammation, liver lipid content or AMPK phosphorylation of ACC.

  13. Highly Sensitive and Selective Gas Sensor Using Hydrophilic and Hydrophobic Graphenes

    Science.gov (United States)

    Some, Surajit; Xu, Yang; Kim, Youngmin; Yoon, Yeoheung; Qin, Hongyi; Kulkarni, Atul; Kim, Taesung; Lee, Hyoyoung

    2013-01-01

    New hydrophilic 2D graphene oxide (GO) nanosheets with various oxygen functional groups were employed to maintain high sensitivity in highly unfavorable environments (extremely high humidity, strong acidic or basic). Novel one-headed polymer optical fiber sensor arrays using hydrophilic GO and hydrophobic reduced graphene oxide (rGO) were carefully designed, leading to the selective sensing of volatile organic gases for the first time. The two physically different surfaces of GO and rGO could provide the sensing ability to distinguish between tetrahydrofuran (THF) and dichloromethane (MC), respectively, which is the most challenging issue in the area of gas sensors. The eco-friendly physical properties of GO allowed for faster sensing and higher sensitivity when compared to previous results for rGO even under extreme environments of over 90% humidity, making it the best choice for an environmentally friendly gas sensor. PMID:23736838

  14. Improved support films for electron microscopy of beam sensitive specimens

    International Nuclear Information System (INIS)

    Taylor, J.R.; Glaeser, R.M.

    1987-01-01

    Preliminary results indicate that technical innovations can address the problem of beam-induced movement and provide improved prospects for high resolution imaging of beam-sensitive specimens. Second-generation experiments with microgrid supports are in progress with efforts focusing on the objectives of maximizing the contact between the carbon film and its microgrid support and on improving the flatness of microgrids. When more robust support films are available they will be used in conjunction with small spot illumination. 4 refs., 2 figs

  15. ASH structure alignment package: Sensitivity and selectivity in domain classification

    Directory of Open Access Journals (Sweden)

    Toh Hiroyuki

    2007-04-01

    Full Text Available Abstract Background Structure alignment methods offer the possibility of measuring distant evolutionary relationships between proteins that are not visible by sequence-based analysis. However, the question of how structural differences and similarities ought to be quantified in this regard remains open. In this study we construct a training set of sequence-unique CATH and SCOP domains, from which we develop a scoring function that can reliably identify domains with the same CATH topology and SCOP fold classification. The score is implemented in the ASH structure alignment package, for which the source code and a web service are freely available from the PDBj website http://www.pdbj.org/ASH/. Results The new ASH score shows increased selectivity and sensitivity compared with values reported for several popular programs using the same test set of 4,298,905 structure pairs, yielding an area of .96 under the receiver operating characteristic (ROC curve. In addition, weak sequence homologies between similar domains are revealed that could not be detected by BLAST sequence alignment. Also, a subset of domain pairs is identified that exhibit high similarity, even though their CATH and SCOP classification differs. Finally, we show that the ranking of alignment programs based solely on geometric measures depends on the choice of the quality measure. Conclusion ASH shows high selectivity and sensitivity with regard to domain classification, an important step in defining distantly related protein sequence families. Moreover, the CPU cost per alignment is competitive with the fastest programs, making ASH a practical option for large-scale structure classification studies.

  16. Voluntary exercise improves insulin sensitivity and adipose tissue inflammation in diet-induced obese mice

    OpenAIRE

    Bradley, Richard L.; Jeon, Justin Y.; Liu, Fen-Fen; Maratos-Flier, Eleftheria

    2008-01-01

    Exercise promotes weight loss and improves insulin sensitivity. However, the molecular mechanisms mediating its beneficial effects are not fully understood. Obesity correlates with increased production of inflammatory cytokines, which in turn, contributes to systemic insulin resistance. To test the hypothesis that exercise mitigates this inflammatory response, thereby improving insulin sensitivity, we developed a model of voluntary exercise in mice made obese by feeding of a high fat/high suc...

  17. Improved sensitivity, safety and laboratory turnaround time in the diagnosis of pulmonary tuberculosis by use of bleach sedimentation

    Directory of Open Access Journals (Sweden)

    Ameh James

    2015-11-01

    Full Text Available Background: Inadequate diagnostic processes and human resources in laboratories contribute to a high burden of tuberculosis (TB in low- and middle-income countries. Direct smear microscopy is relied on for TB diagnosis; however, sensitivity rates vary. To improve sensitivity of direct microscopy, the researchers employed several approaches, including sputum digestion and concentration of acid-fast bacilli (AFB, a technique which uses commercial bleach. Objectives: This study compared methods used to diagnose active Mycobacterium tuberculosis infections. Methods: Three sputum specimens were collected from each of 340 participants in Abuja, Nigeria, over two consecutive days. Direct microscopy was performed on all specimens; following microscopy, one specimen from each patient was selected randomly for bleach sedimentation and one for Lowenstein-Jensen culture. Results: Direct microscopy produced 28.8% AFB-positive results, whilst bleach sedimentation resulted in 30.3%. When compared with the cultures, 26.5% were AFB true positive using direct microscopy and 27.1% using bleach sedimentation. Whilst the specificity rate between these two methods was not statistically significant (P = 0.548, the sensitivity rate was significant (P = 0.004. Conclusion: Based on these results, bleach increases the sensitivity of microscopy compared with direct smear and has similar specificity. When diagnosing new cases of pulmonary TB, one bleach-digested smear is as sensitive as three direct smears, reducing waiting times for patients and ensuring the safety of laboratory technicians.

  18. Highly improved sensibility and selectivity ethanol sensor of mesoporous Fe-doped NiO nanowires

    Science.gov (United States)

    Li, X. Q.; Wei, J. Q.; Xu, J. C.; Jin, H. X.; Jin, D. F.; Peng, X. L.; Hong, B.; Li, J.; Yang, Y. T.; Ge, H. L.; Wang, Xinqing

    2017-12-01

    In this paper, nickel oxides (NiO) and iron (Fe)-doped NiO nanowires (NWs) with the various doping content (from 1 to 9 at%) were synthesized by using SBA-15 templates with the nanocasting method. All samples were synthesized in the same conditions and exhibited the same mesoporous-structures, uniform diameter, and defects. Mesoporous-structures with high surface area created more active sites for the adsorption of oxygen on the surface of all samples, resulting in the smaller surface resistance in air. The impurity energy levels from the donor Fe-doping provided electrons to neutralize the holes of p-type Fe-doped NiO NWs, which greatly enhanced the total resistance. The comparative gas-sensing study between NiO NWs and Fe-doped NiO NWs indicated that the high-valence donor Fe-doping obviously improved the ethanol sensitivity and selectivity for Fe-doped NiO NWs. And Ni0.94Fe0.06O1.03 NWs sensor presented the highest sensitivity of 14.30 toward ethanol gas at 320 °C for the high-valence metal-doping.

  19. An enhanced electronic topology aimed at improving the phase sensitivity of GMI sensors

    International Nuclear Information System (INIS)

    Costa Silva, E; Gusmão, L A P; Hall Barbosa, C R; Costa Monteiro, E

    2014-01-01

    The giant magnetoimpedance effect (GMI) is used in the most recent technologies developed for the detection of magnetic fields, showing potential to be applied in the measurement of ultra-weak fields. GMI samples exhibit a huge dependency of their electrical impedance on the magnetic field, which makes them excellent magnetic sensors. In spite of GMI magnetometers being mostly based on magnitude impedance characteristics, it was previously verified that sensitivity could be significantly increased by reading the impedance phase. Pursuing this idea, a phase-based GMI magnetometer has been already developed as well as an electronic configuration capable of improving the phase sensitivity of GMI samples. However, when using this topology, it was noted that the sensitivity improvement comes at the cost of reduced voltage levels in the reading terminal, degrading the signal-to-noise ratio. Another drawback of the electronic configuration was that it was not capable of enforcing a linear behavior of the impedance phase in the function of the magnetic field in a given operation region. Aiming at overcoming those issues and then optimizing the behavior of the circuit developed to improve the phase sensitivity, this paper mathematically describes a completely new methodology, presents an enhanced newly developed electronic topology and exemplifies its application. (paper)

  20. Perceptual learning improves contrast sensitivity, visual acuity, and foveal crowding in amblyopia.

    Science.gov (United States)

    Barollo, Michele; Contemori, Giulio; Battaglini, Luca; Pavan, Andrea; Casco, Clara

    2017-01-01

    Amblyopic observers present abnormal spatial interactions between a low-contrast sinusoidal target and high-contrast collinear flankers. It has been demonstrated that perceptual learning (PL) can modulate these low-level lateral interactions, resulting in improved visual acuity and contrast sensitivity. We measured the extent and duration of generalization effects to various spatial tasks (i.e., visual acuity, Vernier acuity, and foveal crowding) through PL on the target's contrast detection. Amblyopic observers were trained on a contrast-detection task for a central target (i.e., a Gabor patch) flanked above and below by two high-contrast Gabor patches. The pre- and post-learning tasks included lateral interactions at different target-to-flankers separations (i.e., 2, 3, 4, 8λ) and included a range of spatial frequencies and stimulus durations as well as visual acuity, Vernier acuity, contrast-sensitivity function, and foveal crowding. The results showed that perceptual training reduced the target's contrast-detection thresholds more for the longest target-to-flanker separation (i.e., 8λ). We also found generalization of PL to different stimuli and tasks: contrast sensitivity for both trained and untrained spatial frequencies, visual acuity for Sloan letters, and foveal crowding, and partially for Vernier acuity. Follow-ups after 5-7 months showed not only complete maintenance of PL effects on visual acuity and contrast sensitivity function but also further improvement in these tasks. These results suggest that PL improves facilitatory lateral interactions in amblyopic observers, which usually extend over larger separations than in typical foveal vision. The improvement in these basic visual spatial operations leads to a more efficient capability of performing spatial tasks involving high levels of visual processing, possibly due to the refinement of bottom-up and top-down networks of visual areas.

  1. Improving ecological risk assessment by including bioavailability into species sensitivity distributions: An example for plants exposed to nickel in soil

    International Nuclear Information System (INIS)

    Semenzin, Elena; Temminghoff, Erwin J.M.; Marcomini, Antonio

    2007-01-01

    The variability of species sensitivity distribution (SSD) due to contaminant bioavailability in soil was explored by using nickel as metal of concern. SSDs of toxicity test results of Avena sativa L. originating from different soils and expressed as total content and available (0.01 M CaCl 2 ) extractable concentration were compared to SSDs for terrestrial plants derived from literature toxicity data. Also the 'free' nickel (Ni 2+ ) concentration was calculated and compared. The results demonstrated that SSDs based on total nickel content highly depend on the experimental conditions set up for toxicity testing (i.e. selected soil and pH value) and thus on metal bioavailability in soil, resulting in an unacceptable uncertainty for ecological risk estimation. The use in SSDs of plant toxicity data expressed as 0.01 M CaCl 2 extractable metal strongly reduced the uncertainty in the SSD curve and thus can improve the ERA procedure remarkably by taking bioavailability into account. - The use of bioavailability toxicity data can improve species sensitivity distribution (SSD) curves and thus ecological risk assessment (ERA)

  2. O2 Plasma Etching and Antistatic Gun Surface Modifications for CNT Yarn Microelectrode Improve Sensitivity and Antifouling Properties.

    Science.gov (United States)

    Yang, Cheng; Wang, Ying; Jacobs, Christopher B; Ivanov, Ilia N; Venton, B Jill

    2017-05-16

    Carbon nanotube (CNT) based microelectrodes exhibit rapid and selective detection of neurotransmitters. While different fabrication strategies and geometries of CNT microelectrodes have been characterized, relatively little research has investigated ways to selectively enhance their electrochemical properties. In this work, we introduce two simple, reproducible, low-cost, and efficient surface modification methods for carbon nanotube yarn microelectrodes (CNTYMEs): O 2 plasma etching and antistatic gun treatment. O 2 plasma etching was performed by a microwave plasma system with oxygen gas flow and the optimized time for treatment was 1 min. The antistatic gun treatment flows ions by the electrode surface; two triggers of the antistatic gun was the optimized number on the CNTYME surface. Current for dopamine at CNTYMEs increased 3-fold after O 2 plasma etching and 4-fold after antistatic gun treatment. When the two treatments were combined, the current increased 12-fold, showing the two effects are due to independent mechanisms that tune the surface properties. O 2 plasma etching increased the sensitivity due to increased surface oxygen content but did not affect surface roughness while the antistatic gun treatment increased surface roughness but not oxygen content. The effect of tissue fouling on CNT yarns was studied for the first time, and the relatively hydrophilic surface after O 2 plasma etching provided better resistance to fouling than unmodified or antistatic gun treated CNTYMEs. Overall, O 2 plasma etching and antistatic gun treatment improve the sensitivity of CNTYMEs by different mechanisms, providing the possibility to tune the CNTYME surface and enhance sensitivity.

  3. Does attentional selectivity in the flanker task improve discretely or gradually?

    Directory of Open Access Journals (Sweden)

    Ronald eHübner

    2012-10-01

    Full Text Available An important question is whether attentional selectivity improves discretely or continuously during stimulus processing. In a recent study, Hübner, et al. (2010 found that the discrete DSTP model accounted better for flanker-task data than various continuous improvement models. However, in a subsequent study, White, et al. (2011 introduced the continuous SSP model and showed that it was superior to the DSTP model. From this result they concluded that attentional selectivity improves continuously rather than discretely. Because different stimuli and procedures were used in these two studies, though, we questioned that the superiority of the SSP model holds generally. Therefore, we fit the SSP model to Hübner et al.’s data and found that the DSTP model was again superior. A series of four experiments revealed that model superiority depends on the response-stimulus interval (RSI. Together, our results demonstrate that methodological details can be crucial for model selection, and that further comparisons between the models are needed before it can be decided whether attentional selectivity improves continuously or discretely.

  4. A highly sensitive and selective dimethyl ether sensor based on cataluminescence.

    Science.gov (United States)

    Zhang, Runkun; Cao, Xiaoan; Liu, Yonghui; Peng, Yan

    2010-07-15

    A sensor for detecting dimethyl ether was designed based on the cataluminescence phenomenon when dimethyl ether vapors were passing through the surface of the ceramic heater. The proposed sensor showed high sensitivity and selectivity to dimethyl ether at an optimal temperature of 279 degrees C. Quantitative analysis were performed at a wavelength of 425 nm, the flow rate of carrier air is around 300 mL/min. The linear range of the cataluminescence intensity versus concentration of dimethyl ether is 100-6.0x10(3) ppm with a detection limit of 80 ppm. The sensor response time is 2.5 s. Under the optimized conditions, none or only very low levels of interference were observed while the foreign substances such as benzene, formaldehyde, ammonia, methanol, ethanol, acetaldehyde, acetic acid, acrolein, isopropyl ether, ethyl acetate, glycol ether and 2-methoxyethanol were passing through the sensor. Since the sensor does not need to prepare and fix up the granular catalyst, the simple technology reduces cost, improves stability and extends life span. The method can be applied to facilitate detection of dimethyl ether in the air. The possible mechanism of cataluminescence from the oxidation of dimethyl ether on the surface of ceramic heater was discussed based on the reaction products. Copyright 2010 Elsevier B.V. All rights reserved.

  5. Sensitivity improvement of a fibre Bragg grating pH sensor with elastomeric coating

    Science.gov (United States)

    Yulianti, Ian; Supa'at, A. S. M.; Idrus, Sevia M.; Kurdi, Ojo; Anwar, M. R. S.

    2012-01-01

    A new optical pH sensor based on fibre Bragg grating (FBG) is demonstrated. The sensor consists of a FBG coated with pH sensitive hydrogel. The sensing was performed through the detection of wavelength shifts resulting from the induced strain on the FBG due to mechanical expansion of the hydrogel. An elastomeric coating was applied before the hydrogel coating to improve the sensitivity. The sensor performance was investigated by simulating the hydrogel swelling and the strain induced on the FBG. The swelling of hydrogel due to pH change was modelled using a free-energy function and was solved using the finite element method. With silicone rubber as the elastomer material, the results show that the sensitivity was improved by up to 66% compared to that of the FBG pH sensor without elastomeric coating.

  6. Sensitivity improvement of a fibre Bragg grating pH sensor with elastomeric coating

    International Nuclear Information System (INIS)

    Yulianti, Ian; Supa'at, A S M; Idrus, Sevia M; Anwar, M R S; Kurdi, Ojo

    2012-01-01

    A new optical pH sensor based on fibre Bragg grating (FBG) is demonstrated. The sensor consists of a FBG coated with pH sensitive hydrogel. The sensing was performed through the detection of wavelength shifts resulting from the induced strain on the FBG due to mechanical expansion of the hydrogel. An elastomeric coating was applied before the hydrogel coating to improve the sensitivity. The sensor performance was investigated by simulating the hydrogel swelling and the strain induced on the FBG. The swelling of hydrogel due to pH change was modelled using a free-energy function and was solved using the finite element method. With silicone rubber as the elastomer material, the results show that the sensitivity was improved by up to 66% compared to that of the FBG pH sensor without elastomeric coating

  7. Highly selective and sensitive sensor based on an organic electrochemical transistor for the detection of ascorbic acid.

    Science.gov (United States)

    Zhang, Lijun; Wang, Guiheng; Wu, Di; Xiong, Can; Zheng, Lei; Ding, Yunsheng; Lu, Hongbo; Zhang, Guobing; Qiu, Longzhen

    2018-02-15

    In this study, an organic electrochemical transistor sensor (OECT) with a molecularly imprinted polymer (MIP)-modified gate electrode was prepared for the detection of ascorbic acid (AA). The combination of the amplification function of an OECT and the selective specificity of MIPs afforded a highly sensitive, selective OECT sensor. Cyclic voltammetry and electrochemical impedance spectroscopy measurements were carried out to monitor the stepwise fabrication of the modified electrodes and the adsorption capacity of the MIP/Au electrodes. Atomic force microscopy was employed for examining the surface morphology of the electrodes. Important detection parameters, pH and detection temperature were optimized. With the change in the relative concentration of AA from 1μM to 100μM, the MIP-OECT sensor exhibited a low detection limit of 10nM (S/N > 3) and a sensitivity of 75.3μA channel current change per decade under optimal conditions. In addition, the MIP-OECT sensor exhibited excellent specific recognition ability to AA, which prevented the interference from other structurally similar compounds (e.g., aspartic acid, glucose, uric acid, glycine, glutathione, H 2 O 2 ), and common metal ions (K + , Na + , Ca 2+ , Mg 2+ , and Fe 2+ ). In addition, a series of vitamin C beverages were analyzed to demonstrate the feasibility of the MIP-OECT sensor. Using the proposed principle, several other sensors with improved performance can be constructed via the modification of organic electrochemical transistors with appropriate MIP films. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Histidine–dialkoxyanthracene dyad for selective and sensitive detection of mercury ions

    KAUST Repository

    Patil, Sachin

    2017-12-18

    Histidine-dialkoxyanthracene (HDA) was synthesised as a turn off type fluorescent sensor for fast and sensitive detection of mercury ions (Hg2+) in aqueous media. The two histidine moieties act as ‘claws’ to selectively complex Hg2+. The binding ratio of HDA to Hg2+ was 1:1 (metal-to-ligand ratio). The association constant for Hg2+ towards the receptor HDA obtained from Benesi–Hildebrand plot was found to be 3.22 × 104 M−1 with detection limit as low as 4.7 nM (0.94 μg/L).

  9. Factor analysis improves the selection of prescribing indicators

    DEFF Research Database (Denmark)

    Rasmussen, Hanne Marie Skyggedal; Søndergaard, Jens; Sokolowski, Ineta

    2006-01-01

    OBJECTIVE: To test a method for improving the selection of indicators of general practitioners' prescribing. METHODS: We conducted a prescription database study including all 180 general practices in the County of Funen, Denmark, approximately 472,000 inhabitants. Principal factor analysis was us...... appropriate and inappropriate prescribing, as revealed by the correlation of the indicators in the first factor. CONCLUSION: Correlation and factor analysis is a feasible method that assists the selection of indicators and gives better insight into prescribing patterns....

  10. Improved Diffuse Fluorescence Flow Cytometer Prototype for High Sensitivity Detection of Rare Circulating Cells In Vivo

    Science.gov (United States)

    Pestana, Noah Benjamin

    Accurate quantification of circulating cell populations is important in many areas of pre-clinical and clinical biomedical research, for example, in the study of cancer metastasis or the immune response following tissue and organ transplants. Normally this is done "ex-vivo" by drawing and purifying a small volume of blood and then analyzing it with flow cytometry, hemocytometry or microfludic devices, but the sensitivity of these techniques are poor and the process of handling samples has been shown to affect cell viability and behavior. More recently "in vivo flow cytometry" (IVFC) techniques have been developed where fluorescently-labeled cells flowing in a small blood vessel in the ear or retina are analyzed, but the sensitivity is generally poor due to the small sampling volume. To address this, our group recently developed a method known as "Diffuse Fluorescence Flow Cytometry" (DFFC) that allows detection and counting of rare circulating cells with diffuse photons, offering extremely high single cell counting sensitivity. In this thesis, an improved DFFC prototype was designed and validated. The chief improvements were three-fold, i) improved optical collection efficiency, ii) improved detection electronics, and iii) development of a method to mitigate motion artifacts during in vivo measurements. In combination, these improvements yielded an overall instrument detection sensitivity better than 1 cell/mL in vivo, which is the most sensitive IVFC system reported to date. Second, development and validation of a low-cost microfluidic device reader for analysis of ocular fluids is described. We demonstrate that this device has equivalent or better sensitivity and accuracy compared a fluorescence microscope, but at an order-of-magnitude reduced cost with simplified operation. Future improvements to both instruments are also discussed.

  11. An improvement of LLNA:DA to assess the skin sensitization potential of chemicals.

    Science.gov (United States)

    Zhang, Hongwei; Shi, Ying; Wang, Chao; Zhao, Kangfeng; Zhang, Shaoping; Wei, Lan; Dong, Li; Gu, Wen; Xu, Yongjun; Ruan, Hongjie; Zhi, Hong; Yang, Xiaoyan

    2017-01-01

    We developed a modified local lymph node assay based on ATP (LLNA:DA), termed the Two-Stage LLNA:DA, to further reduce the animal numbers in the identification of sensitizers. In the Two-Stage LLNA:DA procedure, 13 chemicals ranging from non-sensitizers to extreme sensitizers were selected. The first stage used reduced LLNA:DA (rLLNA:DA) to screen out sensitive chemicals. The second stage used LLNA:DA based on OECD 442 (A) to classify those potential sensitizers screened out in the first stage. In the first stage, the SIs of the methyl methacrylate, salicylic acid, methyl salicylate, ethyl salicylate, isopropanol and propanediol were below 1.8 and need not to be tested in the second step. Others continued to be tested by LLNA:DA. In the second stage, sodium lauryl sulphate and xylene were classified as weak sensitizers. a-hexyl cinnamic aldehyde and eugenol were moderate sensitizers. Benzalkonium chloride and glyoxal were strong sensitizers, and phthalic anhydride was an extreme sensitizer. The 9/9, 11/12, 10/11, and 8/13 (positive or negative only) categories of the Two-Stage LLNA:DA were consistent with those from the other methods (LLNA, LLNA:DA, GPMT/BT and HMT/HPTA), suggesting that Two-Stage LLNA:DA have a high coincidence rate with reported data. In conclusion, The Two-Stage LLNA:DA is in line with the "3R" rules, and can be a modification of LLNA:DA but needs more study.

  12. Phosphinic acid functionalized carbon nanotubes for sensitive and selective sensing of chromium(VI)

    Energy Technology Data Exchange (ETDEWEB)

    Deep, Akash, E-mail: dr.akashdeep@csio.res.in; Sharma, Amit L.; Tuteja, Satish K.; Paul, A.K.

    2014-08-15

    Highlights: • SWCNTs have been conjugated with bis(2,4,4-trimethylpentyl) phosphinic acid (PA/d). • SWCNT-PA/d adduct is demonstrated for electrochemical sensing of Cr(VI). • Linear response is obtained for 0.01–10 ppb Cr(VI). • Sensitivity and the limit of detection are 35 ± 4 nA/ppb and 0.01 ppb, respectively. • Proposed sensing of Cr(VI) is selective with respect to many other metals. - Abstract: Single-walled carbon nanotubes (SWCNTs) have been functionalized with a phosphinic acid derivative ‘bis(2,4,4-trimethylpentyl) phosphinic acid’ (PA/d). It has been achieved by treating the chlorinated SWCNTs with PA/d at 80 °C. Successful functionalization and different nanomaterial properties have been investigated by UV–vis–NIR, FTIR, Raman spectroscopy, AFM and FE-SEM. PA/d conjugated SWCNTs (CNT–PA) are dispersible in some common organic solvents, e.g. CH{sub 2}Cl{sub 2}, DMF, CHCl{sub 3}, and THF. The ‘CNT–PA’ complex was spin-casted on boron doped silicon wafer. Thus fabricated sensing electrode is demonstrated for sensitive and selective electrochemical sensing of chromium(VI) ions. A linear response is obtained over a wide range of Cr(VI) concentration (0.01–10 ppb). The sensor's sensitivity and the limit of detection are observed to be 35 ± 4 nA/ppb and 0.01 ppb, respectively. The practical utility of the proposed sensor is demonstrated by determining the Cr(VI) concentration in an industrial effluent sample and an underground water sample.

  13. A colorimetric nitrite detection system with excellent selectivity and high sensitivity based on Ag@Au nanoparticles.

    Science.gov (United States)

    Li, Tianhua; Li, Yonglong; Zhang, Yujie; Dong, Chen; Shen, Zheyu; Wu, Aiguo

    2015-02-21

    Excessive uptake of NO2(-) is detrimental to human health, but the currently available methods used to sensitively detect this ion in the environment are cumbersome and expensive. In this study, we developed an improved NO2(-) detection system based on a redox etching strategy of CTAB-stabilized Ag-Au core-shell nanoparticles (Ag@AuNPs). The detection mechanism was verified by UV-Vis spectroscopy, TEM and XPS. The detection system produces a color change from purple to colorless in response to an increase of NO2(-) concentration. The selectivity of detection of NO2(-), both with the unaided eye and by measurement of UV-Vis spectra, is excellent in relation to other ions, including Cu(2+), Co(2+), Ni(2+), Cr(3+), Al(3+), Pb(2+), Cd(2+), Ca(2+), Ba(2+), Zn(2+), Mn(2+), Mg(2+), Fe(3+), Hg(2+), Ag(+), K(+), F(-), PO4(3-), C2O4(2-), SO3(2-), CO3(2-), SO4(2-), NO3(-) and CH3-COO(-) (Ac(-)). The limit of detection (LOD) for NO2(-) is 1.0 μM by eye and 0.1 μM by UV-Vis spectroscopy. The LOD by eye is lower than the lowest previously reported value (4.0 μM). There is a good linear relationship between A/A0 and the concentration of NO2(-) from 1.0 to 20.0 μM NO2(-), which permits a quantitative assay. The applicability of our detection system was also verified by analysis of NO2(-) in tap water and lake water. The results demonstrate that our Ag@AuNP-based detection system can be used for the rapid colorimetric detection of NO2(-) in complex environmental samples, with excellent selectivity and high sensitivity.

  14. Cheat sensitive quantum bit commitment via pre- and post-selected quantum states

    Science.gov (United States)

    Li, Yan-Bing; Wen, Qiao-Yan; Li, Zi-Chen; Qin, Su-Juan; Yang, Ya-Tao

    2014-01-01

    Cheat sensitive quantum bit commitment is a most important and realizable quantum bit commitment (QBC) protocol. By taking advantage of quantum mechanism, it can achieve higher security than classical bit commitment. In this paper, we propose a QBC schemes based on pre- and post-selected quantum states. The analysis indicates that both of the two participants' cheat strategies will be detected with non-zero probability. And the protocol can be implemented with today's technology as a long-term quantum memory is not needed.

  15. On selecting a sensitive region thickness of a silicon semiconductor detector for operation under counting conditions

    International Nuclear Information System (INIS)

    Pronkin, N.S.; Khakhalin, V.V.

    1972-01-01

    The paper discusses the selection of a thickness of a sensitive area of a silicon semiconductor detector, used in the count regime based on the signal to noise ratio and β-radiation registration efficiency. (author)

  16. Fault diagnosis of rotating machinery using an improved HHT based on EEMD and sensitive IMFs

    International Nuclear Information System (INIS)

    Lei, Yaguo; Zuo, Ming J

    2009-01-01

    A Hilbert–Huang transform (HHT) is a time–frequency technique and has been widely applied to analyzing vibration signals in the field of fault diagnosis of rotating machinery. It analyzes the vibration signals using intrinsic mode functions (IMFs) extracted using empirical mode decomposition (EMD). However, EMD sometimes cannot reveal the signal characteristics accurately because of the problem of mode mixing. Ensemble empirical mode decomposition (EEMD) was developed recently to alleviate this problem. The IMFs generated by EEMD have different sensitivity to faults. Some IMFs are sensitive and closely related to the faults but others are irrelevant. To enhance the accuracy of the HHT in fault diagnosis of rotating machinery, an improved HHT based on EEMD and sensitive IMFs is proposed in this paper. Simulated signals demonstrate the effectiveness of the improved HHT in diagnosing the faults of rotating machinery. Finally, the improved HHT is applied to diagnosing an early rub-impact fault of a heavy oil catalytic cracking machine set, and the application results prove that the improved HHT is superior to the HHT based on all IMFs of EMD

  17. A simple highly sensitive and selective aptamer-based colorimetric sensor for environmental toxins microcystin-LR in water samples.

    Science.gov (United States)

    Li, Xiuyan; Cheng, Ruojie; Shi, Huijie; Tang, Bo; Xiao, Hanshuang; Zhao, Guohua

    2016-03-05

    A simple and highly sensitive aptamer-based colorimetric sensor was developed for selective detection of Microcystin-LR (MC-LR). The aptamer (ABA) was employed as recognition element which could bind MC-LR with high-affinity, while gold nanoparticles (AuNPs) worked as sensing materials whose plasma resonance absorption peaks red shifted upon binding of the targets at a high concentration of sodium chloride. With the addition of MC-LR, the random coil aptamer adsorbed on Au NPs altered into regulated structure to form MC-LR-aptamer complexes and broke away from the surface of Au NPs, leading to the aggregation of AuNPs, and the color converted from red to blue due to the interparticle plasmon coupling. Results showed that our aptamer-based colorimetric sensor exhibited rapid and sensitive detection performance for MC-LR with linear range from 0.5 nM to 7.5 μM and the detection limit reached 0.37 nM. Meanwhile, the pollutants usually coexisting with MC-LR in pollutant water samples had not demonstrated disturbance for detecting of MC-LR. The mechanism was also proposed suggesting that high affinity interaction between aptamer and MC-LR significantly enhanced the sensitivity and selectivity for MC-LR detection. Besides, the established method was utilized in analyzing real water samples and splendid sensitivity and selectivity were obtained as well. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Solid-State NMR on bacterial cells: selective cell wall signal enhancement and resolution improvement using dynamic nuclear polarization

    International Nuclear Information System (INIS)

    Takahashi, Hiroki; Bardet, Michel; De Paepe, Gael; Hediger, Sabine; Ayala, Isabel; Simorre, Jean-Pierre

    2013-01-01

    Dynamic nuclear polarization (DNP) enhanced solid-state nuclear magnetic resonance (NMR) has recently emerged as a powerful technique for the study of material surfaces. In this study, we demonstrate its potential to investigate cell surface in intact cells. Using Bacillus subtilis bacterial cells as an example, it is shown that the polarizing agent 1-(TEMPO-4-oxy)-3-(TEMPO-4-amino)propan-2-ol (TOTAPOL) has a strong binding affinity to cell wall polymers (peptidoglycan). This particular interaction is thoroughly investigated with a systematic study on extracted cell wall materials, disrupted cells, and entire cells, which proved that TOTAPOL is mainly accumulating in the cell wall. This property is used on one hand to selectively enhance or suppress cell wall signals by controlling radical concentrations and on the other hand to improve spectral resolution by means of a difference spectrum. Comparing DNP-enhanced and conventional solid-state NMR, an absolute sensitivity ratio of 24 was obtained on the entire cell sample. This important increase in sensitivity together with the possibility of enhancing specifically cell wall signals and improving resolution really opens new avenues for the use of DNP-enhanced solid-state NMR as an on-cell investigation tool. (authors)

  19. Solid-state NMR on bacterial cells: selective cell wall signal enhancement and resolution improvement using dynamic nuclear polarization.

    Science.gov (United States)

    Takahashi, Hiroki; Ayala, Isabel; Bardet, Michel; De Paëpe, Gaël; Simorre, Jean-Pierre; Hediger, Sabine

    2013-04-03

    Dynamic nuclear polarization (DNP) enhanced solid-state nuclear magnetic resonance (NMR) has recently emerged as a powerful technique for the study of material surfaces. In this study, we demonstrate its potential to investigate cell surface in intact cells. Using Bacillus subtilis bacterial cells as an example, it is shown that the polarizing agent 1-(TEMPO-4-oxy)-3-(TEMPO-4-amino)propan-2-ol (TOTAPOL) has a strong binding affinity to cell wall polymers (peptidoglycan). This particular interaction is thoroughly investigated with a systematic study on extracted cell wall materials, disrupted cells, and entire cells, which proved that TOTAPOL is mainly accumulating in the cell wall. This property is used on one hand to selectively enhance or suppress cell wall signals by controlling radical concentrations and on the other hand to improve spectral resolution by means of a difference spectrum. Comparing DNP-enhanced and conventional solid-state NMR, an absolute sensitivity ratio of 24 was obtained on the entire cell sample. This important increase in sensitivity together with the possibility of enhancing specifically cell wall signals and improving resolution really opens new avenues for the use of DNP-enhanced solid-state NMR as an on-cell investigation tool.

  20. Hall effect biosensors with ultraclean graphene film for improved sensitivity of label-free DNA detection

    KAUST Repository

    Loan, Phan Thi Kim

    2017-07-19

    The quality of graphene strongly affects the performance of graphene-based biosensors which are highly demanded for the sensitive and selective detection of biomolecules, such as DNA. This work reported a novel transfer process for preparing a residue-free graphene film using a thin gold supporting layer. A Hall effect device made of this gold-transferred graphene was demonstrated to significantly enhance the sensitivity (≈ 5 times) for hybridization detection, with a linear detection range of 1 pM – 100nM for DNA target. Our findings provide an efficient method to boost the sensitivity of graphene-based biosensors for DNA recognition.

  1. Object learning improves feature extraction but does not improve feature selection.

    Directory of Open Access Journals (Sweden)

    Linus Holm

    Full Text Available A single glance at your crowded desk is enough to locate your favorite cup. But finding an unfamiliar object requires more effort. This superiority in recognition performance for learned objects has at least two possible sources. For familiar objects observers might: 1 select more informative image locations upon which to fixate their eyes, or 2 extract more information from a given eye fixation. To test these possibilities, we had observers localize fragmented objects embedded in dense displays of random contour fragments. Eight participants searched for objects in 600 images while their eye movements were recorded in three daily sessions. Performance improved as subjects trained with the objects: The number of fixations required to find an object decreased by 64% across the 3 sessions. An ideal observer model that included measures of fragment confusability was used to calculate the information available from a single fixation. Comparing human performance to the model suggested that across sessions information extraction at each eye fixation increased markedly, by an amount roughly equal to the extra information that would be extracted following a 100% increase in functional field of view. Selection of fixation locations, on the other hand, did not improve with practice.

  2. Superior selectivity and sensitivity of blue phosphorus nanotubes in gas sensing applications

    KAUST Repository

    Montes Muñoz, Enrique

    2017-05-23

    On the basis of first principles calculations, we study the adsorption of CO, CO2, NH3, NO, and NO2 molecules on armchair and zigzag blue phosphorus nanotubes. The nanotubes are found to surpass the gas sensing performance of other one-dimensional materials, in particular Si nanowires and carbon nanotubes, and two-dimensional materials, in particular graphene, phosphorene, and MoS2. Investigation of the energetics of the gas adsorption and induced charge transfers indicates that blue phosphorus nanotubes are highly sensitive to N-based molecules, in particular NO2, due to covalent bonding. The current–voltage characteristics of nanotubes connected to Au electrodes are derived by the non-equilibrium Green\\'s function formalism and used to quantitatively evaluate the change in resistivity upon gas adsorption. The observed selectivity and sensitivity properties make blue phosphorus nanotubes superior gas sensors for a wide range of applications.

  3. Island-Model Genomic Selection for Long-Term Genetic Improvement of Autogamous Crops.

    Science.gov (United States)

    Yabe, Shiori; Yamasaki, Masanori; Ebana, Kaworu; Hayashi, Takeshi; Iwata, Hiroyoshi

    2016-01-01

    Acceleration of genetic improvement of autogamous crops such as wheat and rice is necessary to increase cereal production in response to the global food crisis. Population and pedigree methods of breeding, which are based on inbred line selection, are used commonly in the genetic improvement of autogamous crops. These methods, however, produce a few novel combinations of genes in a breeding population. Recurrent selection promotes recombination among genes and produces novel combinations of genes in a breeding population, but it requires inaccurate single-plant evaluation for selection. Genomic selection (GS), which can predict genetic potential of individuals based on their marker genotype, might have high reliability of single-plant evaluation and might be effective in recurrent selection. To evaluate the efficiency of recurrent selection with GS, we conducted simulations using real marker genotype data of rice cultivars. Additionally, we introduced the concept of an "island model" inspired by evolutionary algorithms that might be useful to maintain genetic variation through the breeding process. We conducted GS simulations using real marker genotype data of rice cultivars to evaluate the efficiency of recurrent selection and the island model in an autogamous species. Results demonstrated the importance of producing novel combinations of genes through recurrent selection. An initial population derived from admixture of multiple bi-parental crosses showed larger genetic gains than a population derived from a single bi-parental cross in whole cycles, suggesting the importance of genetic variation in an initial population. The island-model GS better maintained genetic improvement in later generations than the other GS methods, suggesting that the island-model GS can utilize genetic variation in breeding and can retain alleles with small effects in the breeding population. The island-model GS will become a new breeding method that enhances the potential of genomic

  4. Island-Model Genomic Selection for Long-Term Genetic Improvement of Autogamous Crops.

    Directory of Open Access Journals (Sweden)

    Shiori Yabe

    Full Text Available Acceleration of genetic improvement of autogamous crops such as wheat and rice is necessary to increase cereal production in response to the global food crisis. Population and pedigree methods of breeding, which are based on inbred line selection, are used commonly in the genetic improvement of autogamous crops. These methods, however, produce a few novel combinations of genes in a breeding population. Recurrent selection promotes recombination among genes and produces novel combinations of genes in a breeding population, but it requires inaccurate single-plant evaluation for selection. Genomic selection (GS, which can predict genetic potential of individuals based on their marker genotype, might have high reliability of single-plant evaluation and might be effective in recurrent selection. To evaluate the efficiency of recurrent selection with GS, we conducted simulations using real marker genotype data of rice cultivars. Additionally, we introduced the concept of an "island model" inspired by evolutionary algorithms that might be useful to maintain genetic variation through the breeding process. We conducted GS simulations using real marker genotype data of rice cultivars to evaluate the efficiency of recurrent selection and the island model in an autogamous species. Results demonstrated the importance of producing novel combinations of genes through recurrent selection. An initial population derived from admixture of multiple bi-parental crosses showed larger genetic gains than a population derived from a single bi-parental cross in whole cycles, suggesting the importance of genetic variation in an initial population. The island-model GS better maintained genetic improvement in later generations than the other GS methods, suggesting that the island-model GS can utilize genetic variation in breeding and can retain alleles with small effects in the breeding population. The island-model GS will become a new breeding method that enhances the

  5. Nitrogen-Doped Carbon Quantum Dots as Fluorescent Probes for Sensitive and Selective Detection of Nitrite

    Directory of Open Access Journals (Sweden)

    Zhibiao Feng

    2017-11-01

    Full Text Available Nitrites are the upstream precursors of the carcinogenic nitrosamines, which are widely found in the natural environment and many food products. It is important to develop a simple and sensitive sensor for detecting nitrites. In this work, a fluorescence probe based on nitrogen-doped carbon quantum dots (N-CQDs was developed for the sensitive and selective determination of nitrites. At pH 2, the fluorescence of N-CQDs can be selectively quenched by nitrite due to the fact N-nitroso compounds can be formed in the reaction of amide groups with nitrous acid, which results in fluorescence static quenching. Under optimal conditions, fluorescence intensity quenching upon addition of nitrite gives a satisfactory linear relationship covering the linear range of 0.2–20 μM, and the limit of detection (LOD is 40 nM. Moreover, this method has been successfully applied to the determination of nitrites in tap water, which indicates its great potential for monitoring of nitrites in environmental samples.

  6. Sensitivity improvement of a laser interferometer limited by inelastic back-scattering, employing dual readout

    International Nuclear Information System (INIS)

    Meinders, Melanie; Schnabel, Roman

    2015-01-01

    Inelastic back-scattering of stray light is a long-standing and fundamental problem in high-sensitivity interferometric measurements and a potential limitation for advanced gravitational-wave (GW) detectors. The emerging parasitic interferences cannot be distinguished from a scientific signal via conventional single readout. In this work, we propose the subtraction of inelastic back-scatter signals by employing dual homodyne detection on the output light, and demonstrate it for a table-top Michelson interferometer. The additional readout contains solely parasitic signals and is used to model the scatter source. Subtraction of the scatter signal reduces the noise spectral density and thus improves the measurement sensitivity. Our scheme is qualitatively different from the previously demonstrated vetoing of scatter signals and opens a new path for improving the sensitivity of future GW detectors and other back-scatter limited devices. (paper)

  7. Capped Mesoporous Silica Nanoparticles for the Selective and Sensitive Detection of Cyanide.

    Science.gov (United States)

    Sayed, Sameh El; Licchelli, Maurizio; Martínez-Máñez, Ramón; Sancenón, Félix

    2017-10-18

    The development of easy and affordable methods for the detection of cyanide is of great significance due to the high toxicity of this anion and the potential risks associated with its pollution. Herein, optical detection of cyanide in water has been achieved by using a hybrid organic-inorganic nanomaterial. Mesoporous silica nanoparticles were loaded with [Ru(bipy) 3 ] 2+ , functionalized with macrocyclic nickel(II) complex subunits, and capped with a sterically hindering anion (hexametaphosphate). Cyanide selectively induces demetallation of nickel(II) complexes and the removal of capping anions from the silica surface, allowing the release of the dye and the consequent increase in fluorescence intensity. The response of the capped nanoparticles in aqueous solution is highly selective and sensitive towards cyanide with a limit of detection of 2 μm. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Carbon nanotubes-functionalized urchin-like In2S3 nanostructure for sensitive and selective electrochemical sensing of dopamine

    International Nuclear Information System (INIS)

    Yang, Z.; Huang, X.; Li, J.; Zhang, Y.; Yu, S.; Xu, Q.; Hu, X.

    2012-01-01

    Urchin-like In 2 S 3 nanostructures were functionalized with multi-walled carbon nanotubes (MWCNTs) and deposited on a glassy carbon electrode (GCE) to obtain a new kind of sensor for dopamine (DA). The new electrode was characterized using scanning electron microscopy, energy dispersive X-ray spectroscopy, cyclic voltammetry and differential pulse voltammetry. It is found that the current response toward DA is significantly enhanced compared to that of a bare GCE or a GCE modified with MWCNTs. The peak separation between DA and ascorbic acid (AA) is up to 225 mV. The new electrode also has improved selectivity for DA over AA compared to the bare electrode. The new DA sensor has a wide linear range (0.5-300 μM), high sensitivity (594.9 μA mM -1 cm -2 ) and low detection limit (0.1 μM). CNTs wrapped on urchin-like nanostructures remarkable improve its electrocatalytic activity and thus provide a promising strategy to develop excellent composite materials for electrochemical sensing. (author)

  9. Ultra-sensitive and selective Hg{sup 2+} detection based on fluorescent carbon dots

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ruihua; Li, Haitao; Kong, Weiqian; Liu, Juan [Institute of Functional Nano and Soft Materials (FUNSOM) and Jiangsu Key Laboratory for Carbon-Based Functional Materials and Devices, Soochow University, Suzhou 215123 (China); Liu, Yang, E-mail: yangl@suda.edu.cn [Institute of Functional Nano and Soft Materials (FUNSOM) and Jiangsu Key Laboratory for Carbon-Based Functional Materials and Devices, Soochow University, Suzhou 215123 (China); Tong, Cuiyan, E-mail: tongcy959@nenu.edu.cn [Chemisty Department, Northeast Normal University, Changchun 130024 (China); Zhang, Xing [Institute of Functional Nano and Soft Materials (FUNSOM) and Jiangsu Key Laboratory for Carbon-Based Functional Materials and Devices, Soochow University, Suzhou 215123 (China); Kang, Zhenhui, E-mail: zhkang@suda.edu.cn [Institute of Functional Nano and Soft Materials (FUNSOM) and Jiangsu Key Laboratory for Carbon-Based Functional Materials and Devices, Soochow University, Suzhou 215123 (China)

    2013-07-15

    Graphical abstract: Fluorescent carbon dots were efficiently synthesized by one-step sodium hydroxide-assisted reflux method from PEG and demonstrated to show high selectivity toward Hg2+ ions detection. - Highlights: • FCDs were synthesized by one-step sodium hydroxide-assisted reflux method from PEG. • The FCDs emit blue photoluminescence and have upconversion fluorescent property. • The FCDs show ultra-sensitive detective ability for Hg{sup 2+} ions. - Abstract: Fluorescent carbon dots (FCDs) were efficiently synthesized by one-step sodium hydroxide-assisted reflux method from poly(ethylene glycol) (PEG). The obtained FCDs exhibit excellent water-solubility and high stability. Under the UV irradiation, the FCDs could emit bright blue photoluminescence, and also they were found to show excellent up-conversion fluorescence. It was further demonstrated that such FCDs can serve as effective fluorescent sensing platform for Hg{sup 2+} ions detection with ultra-sensitivity and selectivity. The sensing system achieved a limit of detection as low as 1 fM, which is much lower than all the previous reported sensing systems for Hg{sup 2+} ions detection. This FCDs sensing system has been successfully applied for the analysis of Hg{sup 2+} ions in water samples from river, lake, and tap water, showing good practical feasibility.

  10. Detection of CO{sub 2} using CNT-based sensors: Role of Fe catalyst on sensitivity and selectivity

    Energy Technology Data Exchange (ETDEWEB)

    Tit, Nacir, E-mail: ntit@uaeu.ac.ae [Physics Department, UAE University, P.O. Box 15551, Al-Ain (United Arab Emirates); Ezzi, Mohammed M. Al; Abdullah, Hasan M. [Physics Department, King Fahd University of Petroleum and Minerals, P.O. Box 1690, Dhahran, 31261 (Saudi Arabia); Yusupov, Maksudbek [Research Group PLASMANT, Department of Chemistry, University of Antwerp, Universiteitsplein 1, BE-2610, Wilrijk-Antwerp (Belgium); Kouser, Summayya [Theoretical Sciences Unit, Jawaharlal Nehru Center for Advanced Scientific Research, Jakkur, Bangalore (India); Bahlouli, Hocine [Physics Department, King Fahd University of Petroleum and Minerals, P.O. Box 1690, Dhahran, 31261 (Saudi Arabia); Yamani, Zain H. [Physics Department, King Fahd University of Petroleum and Minerals, P.O. Box 1690, Dhahran, 31261 (Saudi Arabia); Center for Research Excellence in Nanotechnology, KFUPM, P.O. Box 5040, Dhahran 31261 (Saudi Arabia)

    2017-01-15

    The adsorption of CO{sub 2} on surfaces of graphene and carbon nanotubes (CNTs), decorated with Fe atoms, are investigated using the self-consistent-charge density-functional tight-binding (SCC-DFTB) method, neglecting the heat effects. Fe ad-atoms are more stable when they are dispersed on hollow sites. They introduce a large density of states at the Fermi level (N{sub F}); where keeping such density low would help in gas sensing. Furthermore, the Fe ad-atom can weaken the C=O double bonds of the chemisorbed CO{sub 2} molecule, paving the way for oxygen atoms to drain more charges from Fe. Consequently, chemisorption of CO{sub 2} molecules reduces both N{sub F} and the conductance while it enhances the sensitivity with the increasing gas dose. Conducting armchair CNTs (ac-CNTs) have higher sensitivity than graphene and semiconducting zigzag CNTs (zz-CNTs). Comparative study of sensitivity of ac-CNT-Fe composite towards various gases (e.g., O{sub 2}, N{sub 2}, H{sub 2}, H{sub 2}O, CO and CO{sub 2}) has shown high sensitivity and selectivity towards CO, CO{sub 2} and H{sub 2}O gases. - Highlights: • DFTB is used to study Adsorptions of CO{sub 2} molecule on pG and CNT, with Fe catalyst. • Armchair CNT-Fe has higher sensitivity to detect CO{sub 2} than zigzag CNT-Fe and pG-Fe. • Ac-CNT-Fe is highly sensitive and selective towards CO, CO{sub 2} and H{sub 2}O gases. • Keeping Fe ad-atoms dispersed and with low density enhances sensitivity. • Our theoretical results corroborate the experimental findings of Ref. .

  11. Probe Sensor Using Nanostructured Multi-Walled Carbon Nanotube Yarn for Selective and Sensitive Detection of Dopamine

    Directory of Open Access Journals (Sweden)

    Wed Al-Graiti

    2017-04-01

    Full Text Available The demands for electrochemical sensor materials with high strength and durability in physiological conditions continue to grow and novel approaches are being enabled by the advent of new electromaterials and novel fabrication technologies. Herein, we demonstrate a probe-style electrochemical sensor using highly flexible and conductive multi-walled carbon nanotubes (MWNT yarns. The MWNT yarn-based sensors can be fabricated onto micro Pt-wire with a controlled diameter varying from 100 to 300 µm, and then further modified with Nafion via a dip-coating approach. The fabricated micro-sized sensors were characterized by electron microscopy, Raman, FTIR, electrical, and electrochemical measurements. For the first time, the MWNT/Nafion yarn-based probe sensors have been assembled and assessed for high-performance dopamine sensing, showing a significant improvement in both sensitivity and selectivity in dopamine detection in presence of ascorbic acid and uric acid. It offers the potential to be further developed as implantable probe sensors.

  12. Stress improves selective attention towards emotionally neutral left ear stimuli.

    Science.gov (United States)

    Hoskin, Robert; Hunter, M D; Woodruff, P W R

    2014-09-01

    Research concerning the impact of psychological stress on visual selective attention has produced mixed results. The current paper describes two experiments which utilise a novel auditory oddball paradigm to test the impact of psychological stress on auditory selective attention. Participants had to report the location of emotionally-neutral auditory stimuli, while ignoring task-irrelevant changes in their content. The results of the first experiment, in which speech stimuli were presented, suggested that stress improves the ability to selectively attend to left, but not right ear stimuli. When this experiment was repeated using tonal stimuli the same result was evident, but only for female participants. Females were also found to experience greater levels of distraction in general across the two experiments. These findings support the goal-shielding theory which suggests that stress improves selective attention by reducing the attentional resources available to process task-irrelevant information. The study also demonstrates, for the first time, that this goal-shielding effect extends to auditory perception. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Selection of productivity improvement techniques via mathematical modeling

    Directory of Open Access Journals (Sweden)

    Mahassan M. Khater

    2011-07-01

    Full Text Available This paper presents a new mathematical model to select an optimal combination of productivity improvement techniques. The proposed model of this paper considers four-stage cycle productivity and the productivity is assumed to be a linear function of fifty four improvement techniques. The proposed model of this paper is implemented for a real-world case study of manufacturing plant. The resulted problem is formulated as a mixed integer programming which can be solved for optimality using traditional methods. The preliminary results of the implementation of the proposed model of this paper indicate that the productivity can be improved through a change on equipments and it can be easily applied for both manufacturing and service industries.

  14. Channel selection for automatic seizure detection

    DEFF Research Database (Denmark)

    Duun-Henriksen, Jonas; Kjaer, Troels Wesenberg; Madsen, Rasmus Elsborg

    2012-01-01

    Objective: To investigate the performance of epileptic seizure detection using only a few of the recorded EEG channels and the ability of software to select these channels compared with a neurophysiologist. Methods: Fifty-nine seizures and 1419 h of interictal EEG are used for training and testing...... of an automatic channel selection method. The characteristics of the seizures are extracted by the use of a wavelet analysis and classified by a support vector machine. The best channel selection method is based upon maximum variance during the seizure. Results: Using only three channels, a seizure detection...... sensitivity of 96% and a false detection rate of 0.14/h were obtained. This corresponds to the performance obtained when channels are selected through visual inspection by a clinical neurophysiologist, and constitutes a 4% improvement in sensitivity compared to seizure detection using channels recorded...

  15. Improved negative selection protocol for Plasmodium berghei in the rodent malarial model

    Directory of Open Access Journals (Sweden)

    Orr Rachael Y

    2012-03-01

    Full Text Available Abstract An improved methodology is presented here for transgenic Plasmodium berghei lines that express the negative selectable marker yFCU (a bifunctional protein that combines yeast cytosine deaminase and uridyl phosphoribosyl transferase (UPRT and substitutes delivery of selection drug 5-fluorocytosine (5FC by intraperitoneal injection for administration via the drinking water of the mice. The improved methodology is shown to be as effective, less labour-intensive, reduces animal handling and animal numbers required for successful selection thereby contributing to two of the "three Rs" of animal experimentation, namely refinement and reduction.

  16. Sensitive, selective nanoantenna-based biosensor platform for compact, in-situ exo-life detection and astronaut life support

    Data.gov (United States)

    National Aeronautics and Space Administration — We aim to develop a new nanotechnology-enabled sensing platform exceeding the sensitivity and selectivity of the current state-of-art (SOA) in portable, low-mass,...

  17. Bi-harmonic cantilever design for improved measurement sensitivity in tapping-mode atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Loganathan, Muthukumaran; Bristow, Douglas A., E-mail: dbristow@mst.edu [Department of Mechanical and Aerospace Engineering, Missouri University of Science and Technology, Rolla, Missouri 65401 (United States)

    2014-04-15

    This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.

  18. Bi-harmonic cantilever design for improved measurement sensitivity in tapping-mode atomic force microscopy.

    Science.gov (United States)

    Loganathan, Muthukumaran; Bristow, Douglas A

    2014-04-01

    This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.

  19. Hall effect biosensors with ultraclean graphene film for improved sensitivity of label-free DNA detection

    KAUST Repository

    Loan, Phan Thi Kim; Wu, Dongqin; Ye, Chen; Li, Xiaoqing; Tra, Vu Thanh; Wei, Qiuping; Fu, Li; Yu, Aimin; Li, Lain-Jong; Lin, Cheng-Te

    2017-01-01

    The quality of graphene strongly affects the performance of graphene-based biosensors which are highly demanded for the sensitive and selective detection of biomolecules, such as DNA. This work reported a novel transfer process for preparing a

  20. Ultra-sensitive and selective detection of mercury ion (Hg2+) using free-standing silicon nanowire sensors

    Science.gov (United States)

    Jin, Yan; Gao, Anran; Jin, Qinghui; Li, Tie; Wang, Yuelin; Zhao, Jianlong

    2018-04-01

    In this paper, ultra-sensitive and highly selective Hg2+ detection in aqueous solutions was studied by free-standing silicon nanowire (SiNW) sensors. The all-around surface of SiNW arrays was functionalized with (3-Mercaptopropyl)trimethoxysilane serving as Hg2+ sensitive layer. Due to effective electrostatic control provided by the free-standing structure, a detection limit as low as 1 ppt was obtained. A linear relationship (R 2 = 0.9838) between log(CHg2+ ) and a device current change from 1 ppt to 5 ppm was observed. Furthermore, the developed SiNW sensor exhibited great selectivity for Hg2+ over other heavy metal ions, including Cd2+. Given the extraordinary ability for real-time Hg2+ detection, the small size and low cost of the SiNW device, it is expected to be a potential candidate in field detection of environmentally toxic mercury.

  1. Improving mass candidate detection in mammograms via feature maxima propagation and local feature selection.

    Science.gov (United States)

    Melendez, Jaime; Sánchez, Clara I; van Ginneken, Bram; Karssemeijer, Nico

    2014-08-01

    Mass candidate detection is a crucial component of multistep computer-aided detection (CAD) systems. It is usually performed by combining several local features by means of a classifier. When these features are processed on a per-image-location basis (e.g., for each pixel), mismatching problems may arise while constructing feature vectors for classification, which is especially true when the behavior expected from the evaluated features is a peaked response due to the presence of a mass. In this study, two of these problems, consisting of maxima misalignment and differences of maxima spread, are identified and two solutions are proposed. The first proposed method, feature maxima propagation, reproduces feature maxima through their neighboring locations. The second method, local feature selection, combines different subsets of features for different feature vectors associated with image locations. Both methods are applied independently and together. The proposed methods are included in a mammogram-based CAD system intended for mass detection in screening. Experiments are carried out with a database of 382 digital cases. Sensitivity is assessed at two sets of operating points. The first one is the interval of 3.5-15 false positives per image (FPs/image), which is typical for mass candidate detection. The second one is 1 FP/image, which allows to estimate the quality of the mass candidate detector's output for use in subsequent steps of the CAD system. The best results are obtained when the proposed methods are applied together. In that case, the mean sensitivity in the interval of 3.5-15 FPs/image significantly increases from 0.926 to 0.958 (p < 0.0002). At the lower rate of 1 FP/image, the mean sensitivity improves from 0.628 to 0.734 (p < 0.0002). Given the improved detection performance, the authors believe that the strategies proposed in this paper can render mass candidate detection approaches based on image location classification more robust to feature

  2. Systematic wavelength selection for improved multivariate spectral analysis

    Science.gov (United States)

    Thomas, Edward V.; Robinson, Mark R.; Haaland, David M.

    1995-01-01

    Methods and apparatus for determining in a biological material one or more unknown values of at least one known characteristic (e.g. the concentration of an analyte such as glucose in blood or the concentration of one or more blood gas parameters) with a model based on a set of samples with known values of the known characteristics and a multivariate algorithm using several wavelength subsets. The method includes selecting multiple wavelength subsets, from the electromagnetic spectral region appropriate for determining the known characteristic, for use by an algorithm wherein the selection of wavelength subsets improves the model's fitness of the determination for the unknown values of the known characteristic. The selection process utilizes multivariate search methods that select both predictive and synergistic wavelengths within the range of wavelengths utilized. The fitness of the wavelength subsets is determined by the fitness function F=.function.(cost, performance). The method includes the steps of: (1) using one or more applications of a genetic algorithm to produce one or more count spectra, with multiple count spectra then combined to produce a combined count spectrum; (2) smoothing the count spectrum; (3) selecting a threshold count from a count spectrum to select these wavelength subsets which optimize the fitness function; and (4) eliminating a portion of the selected wavelength subsets. The determination of the unknown values can be made: (1) noninvasively and in vivo; (2) invasively and in vivo; or (3) in vitro.

  3. Improving sensitivity in micro-free flow electrophoresis using signal averaging

    Science.gov (United States)

    Turgeon, Ryan T.; Bowser, Michael T.

    2009-01-01

    Microfluidic free-flow electrophoresis (μFFE) is a separation technique that separates continuous streams of analytes as they travel through an electric field in a planar flow channel. The continuous nature of the μFFE separation suggests that approaches more commonly applied in spectroscopy and imaging may be effective in improving sensitivity. The current paper describes the S/N improvements that can be achieved by simply averaging multiple images of a μFFE separation; 20–24-fold improvements in S/N were observed by averaging the signal from 500 images recorded for over 2 min. Up to an 80-fold improvement in S/N was observed by averaging 6500 images. Detection limits as low as 14 pM were achieved for fluorescein, which is impressive considering the non-ideal optical set-up used in these experiments. The limitation to this signal averaging approach was the stability of the μFFE separation. At separation times longer than 20 min bubbles began to form at the electrodes, which disrupted the flow profile through the device, giving rise to erratic peak positions. PMID:19319908

  4. Total sensitivity and uncertainty analysis for LWR pin-cells with improved UNICORN code

    International Nuclear Information System (INIS)

    Wan, Chenghui; Cao, Liangzhi; Wu, Hongchun; Shen, Wei

    2017-01-01

    Highlights: • A new model is established for the total sensitivity and uncertainty analysis. • The NR approximation applied in S&U analysis can be avoided by the new model. • Sensitivity and uncertainty analysis is performed to PWR pin-cells by the new model. • The effects of the NR approximation for the PWR pin-cells are quantified. - Abstract: In this paper, improvements to the multigroup cross-section perturbation model have been proposed and applied in the self-developed UNICORN code, which is capable of performing the total sensitivity and total uncertainty analysis for the neutron-physics calculations by applying the direct numerical perturbation method and the statistical sampling method respectively. The narrow resonance (NR) approximation was applied in the multigroup cross-section perturbation model, implemented in UNICORN. As improvements to the NR approximation to refine the multigroup cross-section perturbation model, an ultrafine-group cross-section perturbation model has been established, in which the actual perturbations are applied to the ultrafine-group cross-section library and the reconstructions of the resonance cross sections are performed by solving the neutron slowing-down equation. The total sensitivity and total uncertainty analysis were then applied to the LWR pin-cells, using both the multigroup and the ultrafine-group cross-section perturbation models. The numerical results show that the NR approximation overestimates the relative sensitivity coefficients and the corresponding uncertainty results for the LWR pin-cells, and the effects of the NR approximation are significant for σ_(_n_,_γ_) and σ_(_n_,_e_l_a_s_) of "2"3"8U. Therefore, the effects of the NR approximation applied in the total sensitivity and total uncertainty analysis for the neutron-physics calculations of LWR should be taken into account.

  5. Improving Otolaryngology Residency Selection Using Principles from Personnel Psychology.

    Science.gov (United States)

    Bowe, Sarah N; Laury, Adrienne M; Gray, Stacey T

    2017-06-01

    There has been a heightened focus on improving the resident selection process, particularly within highly competitive specialties. Previous research, however, has generally lacked a theoretical background, leading to inconsistent and biased results. Our recently published systematic review examining applicant characteristics and performance in residency can provide historical insight into the predictors (ie, constructs) and outcomes (ie, criteria) previously deemed pertinent by the otolaryngology community. Personnel psychology uses evidence-based practices to identify the most qualified candidates for employment using a variety of selection methods. Extensive research in this discipline has shown that integrity tests, structured interviews, work samples, and conscientiousness offer the greatest increase in validity when combined with general cognitive ability. Blending past research knowledge with the principles of personnel selection can provide the necessary foundation with which to engage in theory-driven, longitudinal studies on otolaryngology resident selection moving forward.

  6. Material Selection for Dye Sensitized Solar Cells Using Multiple Attribute Decision Making Approach

    Directory of Open Access Journals (Sweden)

    Sarita Baghel

    2014-01-01

    Full Text Available Dye sensitized solar cells (DSCs provide a potential alternative to conventional p-n junction photovoltaic devices. The semiconductor thin film plays a crucial role in the working of DSC. This paper aims at formulating a process for the selection of optimum semiconductor material for nanostructured thin film using multiple attribute decision making (MADM approach. Various possible available semiconducting materials and their properties like band gap, cost, mobility, rate of electron injection, and static dielectric constant are considered and MADM technique is applied to select the best suited material. It was found that, out of all possible candidates, titanium dioxide (TiO2 is the best semiconductor material for application in DSC. It was observed that the proposed results are in good agreement with the experimental findings.

  7. Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile likelihood approach

    Energy Technology Data Exchange (ETDEWEB)

    Hehn, L. [Karlsruher Institut fuer Technologie, Institut fuer Kernphysik, Karlsruhe (Germany); Armengaud, E.; Boissiere, T. de; Gros, M.; Navick, X.F.; Nones, C.; Paul, B. [CEA Saclay, DSM/IRFU, Gif-sur-Yvette Cedex (France); Arnaud, Q. [Univ Lyon, Universite Claude Bernard Lyon 1, CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, Lyon (France); Queen' s University, Kingston (Canada); Augier, C.; Billard, J.; Cazes, A.; Charlieux, F.; Jesus, M. de; Gascon, J.; Juillard, A.; Queguiner, E.; Sanglard, V.; Vagneron, L. [Univ Lyon, Universite Claude Bernard Lyon 1, CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, Lyon (France); Benoit, A.; Camus, P. [Institut Neel, CNRS/UJF, Grenoble (France); Berge, L.; Chapellier, M.; Dumoulin, L.; Giuliani, A.; Le-Sueur, H.; Marnieros, S.; Olivieri, E.; Poda, D. [CSNSM, Univ. Paris-Sud, CNRS/IN2P3, Universite Paris-Saclay, Orsay (France); Bluemer, J. [Karlsruher Institut fuer Technologie, Institut fuer Kernphysik, Karlsruhe (Germany); Karlsruher Institut fuer Technologie, Institut fuer Experimentelle Kernphysik, Karlsruhe (Germany); Broniatowski, A. [CSNSM, Univ. Paris-Sud, CNRS/IN2P3, Universite Paris-Saclay, Orsay (France); Karlsruher Institut fuer Technologie, Institut fuer Experimentelle Kernphysik, Karlsruhe (Germany); Eitel, K.; Kozlov, V.; Siebenborn, B. [Karlsruher Institut fuer Technologie, Institut fuer Kernphysik, Karlsruhe (Germany); Foerster, N.; Heuermann, G.; Scorza, S. [Karlsruher Institut fuer Technologie, Institut fuer Experimentelle Kernphysik, Karlsruhe (Germany); Jin, Y. [Laboratoire de Photonique et de Nanostructures, CNRS, Route de Nozay, Marcoussis (France); Kefelian, C. [Univ Lyon, Universite Claude Bernard Lyon 1, CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, Lyon (France); Karlsruher Institut fuer Technologie, Institut fuer Experimentelle Kernphysik, Karlsruhe (Germany); Kleifges, M.; Tcherniakhovski, D.; Weber, M. [Karlsruher Institut fuer Technologie, Institut fuer Prozessdatenverarbeitung und Elektronik, Karlsruhe (Germany); Kraus, H. [University of Oxford, Department of Physics, Oxford (United Kingdom); Kudryavtsev, V.A. [University of Sheffield, Department of Physics and Astronomy, Sheffield (United Kingdom); Pari, P. [CEA Saclay, DSM/IRAMIS, Gif-sur-Yvette (France); Piro, M.C. [CSNSM, Univ. Paris-Sud, CNRS/IN2P3, Universite Paris-Saclay, Orsay (France); Rensselaer Polytechnic Institute, Troy, NY (United States); Rozov, S.; Yakushev, E. [JINR, Laboratory of Nuclear Problems, Dubna, Moscow Region (Russian Federation); Schmidt, B. [Karlsruher Institut fuer Technologie, Institut fuer Kernphysik, Karlsruhe (Germany); Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2016-10-15

    We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range m{sub χ} element of [4, 30] GeV/c{sup 2} with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from γ- and β-radiation, recoils from {sup 206}Pb and neutrons as well as detector intrinsic backgrounds were modelled from data outside the region of interest and constrained in the analysis. The basic data selection and most of the background models are the same as those used in a previously published analysis based on boosted decision trees (BDT) [1]. For the likelihood approach applied in the analysis presented here, a larger signal efficiency and a subtraction of the expected background lead to a higher sensitivity, especially for the lowest WIMP masses probed. No statistically significant signal was found and upper limits on the spin-independent WIMP-nucleon scattering cross section can be set with a hypothesis test based on the profile likelihood test statistics. The 90 % C.L. exclusion limit set for WIMPs with m{sub χ} = 4 GeV/c{sup 2} is 1.6 x 10{sup -39} cm{sup 2}, which is an improvement of a factor of seven with respect to the BDT-based analysis. For WIMP masses above 15 GeV/c{sup 2} the exclusion limits found with both analyses are in good agreement. (orig.)

  8. Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin.

    Science.gov (United States)

    Zhao, Changzhi; Wan, Li; Jiang, Li; Wang, Qin; Jiao, Kui

    2008-12-01

    A cholesterol biosensor based on direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode has been developed for highly sensitive and selective analysis of serum samples. Modified by films containing hemoglobin and cholesterol oxidase, the electrode was prepared by encapsulation of enzyme in chitosan matrix. The hydrogen peroxide produced by the catalytic oxidation of cholesterol by cholesterol oxidase was reduced electrocatalytically by immobilized hemoglobin and used to obtain a sensitive amperometric response to cholesterol. The linear response of cholesterol concentrations ranged from 1.00 x 10(-5) to 6.00 x 10(-4) mol/L, with a correlation coefficient of 0.9969 and estimated detection limit of cholesterol of 9.5 micromol/L at a signal/noise ratio of 3. The cholesterol biosensor can efficiently exclude interference by the commonly coexisting ascorbic acid, uric acid, dopamine, and epinephrine. The sensitivity to the change in the concentration of cholesterol as the slope of the calibration curve was 0.596 A/M. The relative standard deviation was under 4.0% (n=5) for the determination of real samples. The biosensor is satisfactory in the determination of human serum samples.

  9. Hall effect biosensors with ultraclean graphene film for improved sensitivity of label-free DNA detection.

    Science.gov (United States)

    Loan, Phan Thi Kim; Wu, Dongqin; Ye, Chen; Li, Xiaoqing; Tra, Vu Thanh; Wei, Qiuping; Fu, Li; Yu, Aimin; Li, Lain-Jong; Lin, Cheng-Te

    2018-01-15

    The quality of graphene strongly affects the performance of graphene-based biosensors which are highly demanded for the sensitive and selective detection of biomolecules, such as DNA. This work reported a novel transfer process for preparing a residue-free graphene film using a thin gold supporting layer. A Hall effect device made of this gold-transferred graphene was demonstrated to significantly enhance the sensitivity (≈ 5 times) for hybridization detection, with a linear detection range of 1pM to 100nM for DNA target. Our findings provide an efficient method to boost the sensitivity of graphene-based biosensors for DNA recognition. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Sensitivity improvement of Cerenkov luminescence endoscope with terbium doped Gd{sub 2}O{sub 2}S nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Xin; Chen, Xueli, E-mail: xlchen@xidian.edu.cn, E-mail: jimleung@mail.xidian.edu.cn; Cao, Xu; Zhan, Yonghua; Liang, Jimin, E-mail: xlchen@xidian.edu.cn, E-mail: jimleung@mail.xidian.edu.cn [Engineering Research Center of Molecular and Neuro Imaging of the Ministry of Education and School of Life Science and Technology, Xidian University, Xi' an, Shaanxi 710071 (China); Kang, Fei; Wang, Jing [Department of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University, Xi' an, Shaanxi 710032 (China); Wu, Kaichun [Department of Digestive Diseases, Xijing Hospital, Fourth Military Medical University, Xi' an, Shaanxi 710032 (China)

    2015-05-25

    Our previous study showed a great attenuation for the Cerenkov luminescence endoscope (CLE), resulting in relatively low detection sensitivity of radiotracers. Here, a kind of radioluminescence nanoparticles (RLNPs), terbium doped Gd{sub 2}O{sub 2}S was mixed with the radionuclide {sup 68}Ga to enhance the intensity of emitted luminescence, which finally improved the detection sensitivity of the CLE by using the radioluminescence imaging technique. With the in vitro and in vivo pseudotumor experiments, we showed that the use of RLNPs mixed with the radionuclide {sup 68}Ga enabled superior sensitivity compared with the radionuclide {sup 68}Ga only, with 50-fold improvement on detection sensitivity, which guaranteed meeting the demands of the clinical diagnosis of gastrointestinal tract tumors.

  11. Gamete selection for forage quality improvement in tall fescue

    Science.gov (United States)

    Within the Festuca-Lolium genome complex there is a need for modern breeding approaches that facilitate the rapid development of improved germplasm or cultivars. Traditional recurrent or mass-selection methods for population or synthetic development are labor intensive and time consuming. The use ...

  12. Perception of basic tastes and threshold sensitivity during testing of selected judges

    Directory of Open Access Journals (Sweden)

    Peter Zajác

    Full Text Available Normal 0 false false false SK JA X-NONE The sense of taste is one of the most important human senses. Alteration in taste perception can greately interfere to our lives, because it influences our dietary habits and consequently general human health. Many physiological and external factors can cause the loss of taste perception. These factors include for example certain diseases, the side effect of the use of certain medicaments, head trauma, gender, dietary habbits, smoking, role of saliva, age, stress and many more. In this paper we are discussing perception of basic tastes and treshold sensitivity during testing of selected groupe of 500 sensory judges. A resolution taste test and sensitivity treshold test were performed using basic tastes (sour, bitter, salty, sweet, umami, astringent, metallic. We have found that the perception of basic tastes decreese with human age. Smoking leads to significant errors in the determination of basic tastes. Different mistakes occures in different age categories. This study suggests further researches, investigating various factors influencing taste perception.  doi:10.5219/259

  13. Improving the efficiency of manuscript selection

    Directory of Open Access Journals (Sweden)

    A. Martínez–Abrain

    2009-01-01

    Full Text Available Science relies strongly on the publication of articles in scientific journals and it is clear that decisions concer¬ning which papers merit publishing should be based on a process of manuscript selection that is as objective, repeatable, reliable and transparent as possible. Manuscript selection, however, has many practical downfalls. There is considerable controversy concerning issues such as whether or not the process should be blind both for authors and reviewers in order to prevent biased selection in relation to country of origin (Budden et al., 2008, sex (Young et al. 2008 or research topic (Michaels, 2008. Another critical point is the imbalance between supply and demand of manuscripts as this likely leads to biased selection (Young et al., 2008. Also important is the issue that following rejection, the editor and reviewers of the new journal selected for would-be publication by the authors start the process from scratch, as if the opus had not already passed through a thorough process of peer review. Such rules of play seem to promote the role of sheer luck in the process of manuscript selection. Authors of a rejected paper have the growing hope of "greater luck" the next time regarding reviewer assignment as they believe in the quality of their work. For the correct advancement of science I consider there should be a common global database available to editors, where each manuscript which has been subjected to an SCI journal is recorded. It should include a copy of the editor’s and reviewers’ comments, and also the authors’ replies. Hochberg et al. (2009 recently expressed their concern regarding the fact that authors usually think that manuscript submittal is a stochastic process, whereas in fact reviewers usually focus on the same set of criticisms. To solve this problem they suggest a having colleagues reviewing a manuscript before submission, and b requiring authors to state in a cover letter that reviewer comments from the

  14. Strength Exercise Improves Muscle Mass and Hepatic Insulin Sensitivity in Obese Youth

    NARCIS (Netherlands)

    Van Der Heijden, Gert-Jan; Wang, Zhiyue J.; Chu, Zili; Toffolo, Gianna; Manesso, Erica; Sauer, Pieter J. J.; Sunehag, Agneta L.

    VAN DER HEIJDEN, G.-J., Z. J. WANG, Z. CHU, G. TOFFOLO, E. MANESSO, P. J. J. SAUER, and A. L. SUNEHAG. Strength Exercise Improves Muscle Mass and Hepatic Insulin Sensitivity in Obese Youth. Med. Sci. Sports Exerc., Vol. 42, No. 11, pp. 1973-1980, 2010. Introduction: Data on the metabolic effects of

  15. Strength Exercise Improves Muscle Mass and Hepatic Insulin Sensitivity in Obese Youth

    NARCIS (Netherlands)

    Van Der Heijden, Gert-Jan; Wang, Zhiyue J.; Chu, Zili; Toffolo, Gianna; Manesso, Erica; Sauer, Pieter J. J.; Sunehag, Agneta L.

    2010-01-01

    VAN DER HEIJDEN, G.-J., Z. J. WANG, Z. CHU, G. TOFFOLO, E. MANESSO, P. J. J. SAUER, and A. L. SUNEHAG. Strength Exercise Improves Muscle Mass and Hepatic Insulin Sensitivity in Obese Youth. Med. Sci. Sports Exerc., Vol. 42, No. 11, pp. 1973-1980, 2010. Introduction: Data on the metabolic effects of

  16. Increasing the selectivity and sensitivity of gas sensors for the detection of explosives

    Science.gov (United States)

    Mallin, Daniel

    Over the past decade, the use of improvised explosive devices (IEDs) has increased, domestically and internationally, highlighting a growing need for a method to quickly and reliably detect explosive devices in both military and civilian environments before the explosive can cause damage. Conventional techniques have been successful in explosive detection, however they typically suffer from enormous costs in capital equipment and maintenance, costs in energy consumption, sampling, operational related expenses, and lack of continuous and real-time monitoring. The goal was thus to produce an inexpensive, portable sensor that continuously monitors the environment, quickly detects the presence of explosive compounds and alerts the user. In 2012, here at URI, a sensor design was proposed for the detection of triacetone triperoxide (TATP). The design entailed a thermodynamic gas sensor that measures the heat of decomposition between trace TATP vapor and a metal oxide catalyst film. The sensor was able to detect TATP vapor at the part per million level (ppm) and showed great promise for eventual commercial use, however, the sensor lacked selectivity. Thus, the specific objective of this work was to take the original sensor design proposed in 2012 and to make several key improvements to advance the sensor towards commercialization. It was demonstrated that a sensor can be engineered to detect TATP and ignore the effects of interferent H2O2 molecules by doping SnO2 films with varying amounts of Pd. Compared with a pure SnO2 catalyst, a SnO2, film doped with 8 wt. % Pd had the highest selectivity between TATP and H2O2. Also, at 12 wt. % Pd, the response to TATP and H2O2 was enhanced, indicating that sensitivity, not only selectivity, can be increased by modifying the composition of the catalyst. An orthogonal detection system was demonstrated. The platform consists of two independent sensing mechanisms, one thermodynamic and one conductometric, which take measurements from

  17. Angular selectivity asymmetry of holograms recorded in near infrared sensitive liquid crystal photopolymerizable materials

    Science.gov (United States)

    Harbour, Steven; Galstian, Tigran; Akopyan, Rafik; Galstyan, Artur

    2004-08-01

    We have experimentally observed and theoretically explained the angular selectivity asymmetry in polymer dispersed liquid crystal holograms. Experiments are conducted in compounds with near infrared sensitivity. The coupled-wave theory is used to describe the diffraction properties of obtained anisotropic holographic gratings. Furthermore, the comparison of theory and experiments provides information about the optical axis direction that is defined by the average molecular orientation of the liquid crystal in the polymer matrix.

  18. A framework for improving a seasonal hydrological forecasting system using sensitivity analysis

    Science.gov (United States)

    Arnal, Louise; Pappenberger, Florian; Smith, Paul; Cloke, Hannah

    2017-04-01

    Seasonal streamflow forecasts are of great value for the socio-economic sector, for applications such as navigation, flood and drought mitigation and reservoir management for hydropower generation and water allocation to agriculture and drinking water. However, as we speak, the performance of dynamical seasonal hydrological forecasting systems (systems based on running seasonal meteorological forecasts through a hydrological model to produce seasonal hydrological forecasts) is still limited in space and time. In this context, the ESP (Ensemble Streamflow Prediction) remains an attractive forecasting method for seasonal streamflow forecasting as it relies on forcing a hydrological model (starting from the latest observed or simulated initial hydrological conditions) with historical meteorological observations. This makes it cheaper to run than a standard dynamical seasonal hydrological forecasting system, for which the seasonal meteorological forecasts will first have to be produced, while still producing skilful forecasts. There is thus the need to focus resources and time towards improvements in dynamical seasonal hydrological forecasting systems which will eventually lead to significant improvements in the skill of the streamflow forecasts generated. Sensitivity analyses are a powerful tool that can be used to disentangle the relative contributions of the two main sources of errors in seasonal streamflow forecasts, namely the initial hydrological conditions (IHC; e.g., soil moisture, snow cover, initial streamflow, among others) and the meteorological forcing (MF; i.e., seasonal meteorological forecasts of precipitation and temperature, input to the hydrological model). Sensitivity analyses are however most useful if they inform and change current operational practices. To this end, we propose a method to improve the design of a seasonal hydrological forecasting system. This method is based on sensitivity analyses, informing the forecasters as to which element of

  19. New features and improved uncertainty analysis in the NEA nuclear data sensitivity tool (NDaST)

    Science.gov (United States)

    Dyrda, J.; Soppera, N.; Hill, I.; Bossant, M.; Gulliford, J.

    2017-09-01

    Following the release and initial testing period of the NEA's Nuclear Data Sensitivity Tool [1], new features have been designed and implemented in order to expand its uncertainty analysis capabilities. The aim is to provide a free online tool for integral benchmark testing, that is both efficient and comprehensive, meeting the needs of the nuclear data and benchmark testing communities. New features include access to P1 sensitivities for neutron scattering angular distribution [2] and constrained Chi sensitivities for the prompt fission neutron energy sampling. Both of these are compatible with covariance data accessed via the JANIS nuclear data software, enabling propagation of the resultant uncertainties in keff to a large series of integral experiment benchmarks. These capabilities are available using a number of different covariance libraries e.g., ENDF/B, JEFF, JENDL and TENDL, allowing comparison of the broad range of results it is possible to obtain. The IRPhE database of reactor physics measurements is now also accessible within the tool in addition to the criticality benchmarks from ICSBEP. Other improvements include the ability to determine and visualise the energy dependence of a given calculated result in order to better identify specific regions of importance or high uncertainty contribution. Sorting and statistical analysis of the selected benchmark suite is now also provided. Examples of the plots generated by the software are included to illustrate such capabilities. Finally, a number of analytical expressions, for example Maxwellian and Watt fission spectra will be included. This will allow the analyst to determine the impact of varying such distributions within the data evaluation, either through adjustment of parameters within the expressions, or by comparison to a more general probability distribution fitted to measured data. The impact of such changes is verified through calculations which are compared to a `direct' measurement found by

  20. Quaternary ammonium promoted ultra selective and sensitive fluorescence detection of fluoride ion in water and living cells.

    Science.gov (United States)

    Li, Long; Ji, Yuzhuo; Tang, Xinjing

    2014-10-21

    Highly selective and sensitive fluorescent probes with a quaternary ammonium moiety have been rationally designed and developed for fast and sensitive fluorescence detection of fluoride ion (F(-) from NaF, not TBAF) in aqueous solution and living cells. With the sequestration effect of quaternary ammonium, the detection time was less than 2 min and the detection limit of fluoride ion was as low as 0.57 ppm that is among the lowest detection limits in aqueous solutions of many fluoride fluorescence probes in the literature.

  1. An Improved User Selection Algorithm in Multiuser MIMO Broadcast with Channel Prediction

    Science.gov (United States)

    Min, Zhi; Ohtsuki, Tomoaki

    In multiuser MIMO-BC (Multiple-Input Multiple-Output Broadcasting) systems, user selection is important to achieve multiuser diversity. The optimal user selection algorithm is to try all the combinations of users to find the user group that can achieve the multiuser diversity. Unfortunately, the high calculation cost of the optimal algorithm prevents its implementation. Thus, instead of the optimal algorithm, some suboptimal user selection algorithms were proposed based on semiorthogonality of user channel vectors. The purpose of this paper is to achieve multiuser diversity with a small amount of calculation. For this purpose, we propose a user selection algorithm that can improve the orthogonality of a selected user group. We also apply a channel prediction technique to a MIMO-BC system to get more accurate channel information at the transmitter. Simulation results show that the channel prediction can improve the accuracy of channel information for user selections, and the proposed user selection algorithm achieves higher sum rate capacity than the SUS (Semiorthogonal User Selection) algorithm. Also we discuss the setting of the algorithm threshold. As the result of a discussion on the calculation complexity, which uses the number of complex multiplications as the parameter, the proposed algorithm is shown to have a calculation complexity almost equal to that of the SUS algorithm, and they are much lower than that of the optimal user selection algorithm.

  2. Sensitive and selective tumor imaging with novel and highly activatable fluorescence probes

    International Nuclear Information System (INIS)

    Urano, Yasuteru

    2008-01-01

    Selective and sensitive tumor imaging in vivo is one of the most requested methodologies in medical sciences. Although several imaging modalities have been developed including positron emission tomography (PET) and magnetic resonance (MR) imaging for the detection of tumors, none of these modalities can activate the signals upon being accumulated or uptaken to tumor sites. Among these modalities, only optical fluorescence imaging has a marked advantage, that is, their signals can be dramatically increased upon detecting some biological features. In this short review, I will introduce some recent strategies for activatable optical fluorescence imaging of tumors, and discuss their advantages over other modalities. (author)

  3. Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1

    International Nuclear Information System (INIS)

    Montiel, V. Ruiz-Valdepeñas; Campuzano, S.; Pellicanò, A.; Torrente-Rodríguez, R.M.; Reviejo, A.J.; Cosio, M.S.; Pingarrón, J.M.

    2015-01-01

    Highlights: • First amperometric magnetoimmunosensor for Ara h 1 determination. • Sensitive and selective detection of Ara h 1 in 2 h. • LOD of 6.3 ng mL −1 . • Determinations in food extracts and saliva. • Potential applicability in food safety and consumer protection. - Abstract: A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2 h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at −0.20 V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H 2 O 2 as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0 ng mL −1 Ara h 1, a detection limit of 6.3 ng mL −1 , a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1

  4. Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1

    Energy Technology Data Exchange (ETDEWEB)

    Montiel, V. Ruiz-Valdepeñas, E-mail: victor_lega90@hotmail.com [Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Campuzano, S., E-mail: susanacr@quim.ucm.es [Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Pellicanò, A., E-mail: alessandro.pellicano@unimi.it [Department of Food, Environmental and Nutritional Sciences (DEFENS), University of Milan, Via Celoria 2, 20133 Milan (Italy); Torrente-Rodríguez, R.M., E-mail: rebeca.magnolia@gmail.com [Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Reviejo, A.J., E-mail: reviejo@quim.ucm.es [Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Cosio, M.S., E-mail: stella.cosio@unimi.it [Department of Food, Environmental and Nutritional Sciences (DEFENS), University of Milan, Via Celoria 2, 20133 Milan (Italy); Pingarrón, J.M., E-mail: pingarro@quim.ucm.es [Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain)

    2015-06-23

    Highlights: • First amperometric magnetoimmunosensor for Ara h 1 determination. • Sensitive and selective detection of Ara h 1 in 2 h. • LOD of 6.3 ng mL{sup −1}. • Determinations in food extracts and saliva. • Potential applicability in food safety and consumer protection. - Abstract: A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2 h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at −0.20 V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H{sub 2}O{sub 2} as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0 ng mL{sup −1} Ara h 1, a detection limit of 6.3 ng mL{sup −1}, a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1.

  5. Phage display selects for amylases with improved low pH starch-binding

    NARCIS (Netherlands)

    Verhaert, RMD; Beekwilder, J; Olsthoorn, R; Quax, WJ; Duin, Jan van

    2002-01-01

    Directed evolution of secreted industrial enzymes is hampered by the lack of powerful selection techniques. We have explored surface display to select for enzyme variants with improved binding performance on complex polymeric substrates. By a combination of saturation mutagenesis and phage display

  6. Low Complexity Models to improve Incomplete Sensitivities for Shape Optimization

    Science.gov (United States)

    Stanciu, Mugurel; Mohammadi, Bijan; Moreau, Stéphane

    2003-01-01

    The present global platform for simulation and design of multi-model configurations treat shape optimization problems in aerodynamics. Flow solvers are coupled with optimization algorithms based on CAD-free and CAD-connected frameworks. Newton methods together with incomplete expressions of gradients are used. Such incomplete sensitivities are improved using reduced models based on physical assumptions. The validity and the application of this approach in real-life problems are presented. The numerical examples concern shape optimization for an airfoil, a business jet and a car engine cooling axial fan.

  7. Influence of selecting secondary settling tank sub-models on the calibration of WWTP models – A global sensitivity analysis using BSM2

    DEFF Research Database (Denmark)

    Ramin, Elham; Flores Alsina, Xavier; Sin, Gürkan

    2014-01-01

    This study investigates the sensitivity of wastewater treatment plant (WWTP) model performance to the selection of one-dimensional secondary settling tanks (1-D SST) models with first-order and second-order mathematical structures. We performed a global sensitivity analysis (GSA) on the benchmark...... simulation model No.2 with the input uncertainty associated to the biokinetic parameters in the activated sludge model No. 1 (ASM1), a fractionation parameter in the primary clarifier, and the settling parameters in the SST model. Based on the parameter sensitivity rankings obtained in this study......, the settling parameters were found to be as influential as the biokinetic parameters on the uncertainty of WWTP model predictions, particularly for biogas production and treated water quality. However, the sensitivity measures were found to be dependent on the 1-D SST models selected. Accordingly, we suggest...

  8. A nanoscale Zr-based fluorescent metal-organic framework for selective and sensitive detection of hydrogen sulfide

    Science.gov (United States)

    Li, Yanping; Zhang, Xin; Zhang, Ling; Jiang, Ke; Cui, Yuanjing; Yang, Yu; Qian, Guodong

    2017-11-01

    Hydrogen sulfide (H2S) has been commonly viewed as a gas signaling molecule in various physiological and pathological processes. However, the highly efficient H2S detection still remains challenging. Herein, we designed a new robust nano metal-organic framework (MOF) UiO-66-CH=CH2 as a fluorescent probe for rapid, sensitive and selective detection of biological H2S. UiO-66-CH=CH2 was prepared by heating ZrCl4 and 2-vinylterephthalic acid via a simple method. UiO-66-CH=CH2 displayed fluorescence quenching to H2S and kept excellent selectivity in the presence of biological relevant analytes especially the cysteine and glutathione. This MOF-based probe also exhibited fast response (10 s) and high sensitivity with a detection limit of 6.46 μM which was within the concentration range of biological H2S in living system. Moreover, this constructed MOF featured water-stability, nanoscale (20-30 nm) and low toxicity, which made it a promising candidate for biological H2S sensing.

  9. A highly sensitive and selective aptamer-based colorimetric sensor for the rapid detection of PCB 77.

    Science.gov (United States)

    Cheng, Ruojie; Liu, Siyao; Shi, Huijie; Zhao, Guohua

    2018-01-05

    A highly sensitive, specific and simple colorimetric sensor based on aptamer was established for the detection of polychlorinated biphenyls (PCB 77). The use of unmodified gold nanoparticles as a colorimetric probe for aptamer sensors enabled the highly sensitive and selective detection of polychlorinated biphenyls (PCB 77). A linear range of 0.5nM to 900nM was obtained for the colorimetric assay with a minimum detection limit of 0.05nM. In addition, by the methods of circular dichroism, UV and naked eyes, we found that the 35 base fragments retained after cutting 5 bases from the 5 'end of aptamer plays the most significant role in the PCB 77 specific recognition process. We found a novel way to truncated nucleotides to optimize the detection of PCB 77, and the selected nucleotides also could achieve high affinity with PCB 77. At the same time, the efficient detection of the PCB 77 by our colorimetric sensor in the complex environmental water samples was realized, which shows a good application prospect. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Synthesis and characterization of Ag nanowires: Improved performance in dye sensitized solar cells

    Directory of Open Access Journals (Sweden)

    Safia A. Kazmi

    2016-09-01

    Full Text Available Development of highly efficient dye-sensitized solar cells (DSSCs with good photovoltaic parameters is an active research area of current global interest. Recently, one dimensional nanomaterial, such as nanorods and nanotubes has replaced the nanoparticles used in DSSCs anode because of their ability to improve the electron transport leading to enhanced electron collection efficiency. In the present work, rapid synthesis of silver nanowires (AgNWs was done. The XRD characterization was performed to confirm the formation and size of synthesized AgNWs. It was observed that FWHM of the diffraction peaks was increased with AgNWs concentration in TiO2. The synthesized TiO2AgNWs nanocomposite was used as the photo anode of Dye sensitized solar cell. The I–V characteristics of the solar cell were drawn using standard conditions. It was observed that TiO2AgNWs based solar cells have significantly increased photocurrent density resulting in improved conversion efficiency as compared to pure TiO2 based DSSC.

  11. Two rhodamine lactam modulated lysosome-targetable fluorescence probes for sensitively and selectively monitoring subcellular organelle pH change

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hongmei [Ministry of Education Key Laboratory of Synthetic and Natural Functional Molecule Chemistry, College of Chemistry & Materials Science, Northwest University, Xi' an 710069 (China); Wang, Cuiling [Key Laboratory of Resource Biology and Biotechnology in Western China, Ministry of Education, College of Life Science, Northwest University, Xi' an 710069 (China); She, Mengyao; Zhu, Yuelu; Zhang, Jidong; Yang, Zheng [Ministry of Education Key Laboratory of Synthetic and Natural Functional Molecule Chemistry, College of Chemistry & Materials Science, Northwest University, Xi' an 710069 (China); Liu, Ping, E-mail: liuping@nwu.edu.cn [Ministry of Education Key Laboratory of Synthetic and Natural Functional Molecule Chemistry, College of Chemistry & Materials Science, Northwest University, Xi' an 710069 (China); Wang, Yaoyu [Ministry of Education Key Laboratory of Synthetic and Natural Functional Molecule Chemistry, College of Chemistry & Materials Science, Northwest University, Xi' an 710069 (China); Li, Jianli, E-mail: lijianli@nwu.edu.cn [Ministry of Education Key Laboratory of Synthetic and Natural Functional Molecule Chemistry, College of Chemistry & Materials Science, Northwest University, Xi' an 710069 (China)

    2015-11-05

    Be a powerful technique for convenient detection of pH change in living cells, especially at subcellular level, fluorescent probes has attracted more and more attention. In this work, we designed and synthesized three rhodamine lactam modulated fluorescent probes RS1, RS2 and RS3, which all respond sensitively toward weak acidity (pH range 4–6) via the photophysical property in buffer solution without interference from the other metal ions, and they also show ideal pKa values and excellent reversibility. Particularly, by changing the lone pair electrons distribution of lactam-N atom with different conjugations, RS2 and RS3 exhibit high quantum yield, negligible cytotoxicity and excellent permeability. They are suitable to stain selectively lysosomes of tumor cells and monitor its pH changes sensitively via optical molecular imaging. The above findings suggest that the probes we designed could act as ideal and easy method for investigating the pivotal role of H{sup +} in lysosomes and are potential pH detectors in disease diagnosis through direct intracellular imaging. - Highlights: • Two probes for sensitively and selectively monitoring weak acidic pH change. • The pKa of the probes was highly suitable for staining lysosomes in tumor cells. • The properties of those probes were changed by different conjugate system. • These probes have negligible cytotoxicity and good sensitivity in vivo.

  12. Two rhodamine lactam modulated lysosome-targetable fluorescence probes for sensitively and selectively monitoring subcellular organelle pH change

    International Nuclear Information System (INIS)

    Li, Hongmei; Wang, Cuiling; She, Mengyao; Zhu, Yuelu; Zhang, Jidong; Yang, Zheng; Liu, Ping; Wang, Yaoyu; Li, Jianli

    2015-01-01

    Be a powerful technique for convenient detection of pH change in living cells, especially at subcellular level, fluorescent probes has attracted more and more attention. In this work, we designed and synthesized three rhodamine lactam modulated fluorescent probes RS1, RS2 and RS3, which all respond sensitively toward weak acidity (pH range 4–6) via the photophysical property in buffer solution without interference from the other metal ions, and they also show ideal pKa values and excellent reversibility. Particularly, by changing the lone pair electrons distribution of lactam-N atom with different conjugations, RS2 and RS3 exhibit high quantum yield, negligible cytotoxicity and excellent permeability. They are suitable to stain selectively lysosomes of tumor cells and monitor its pH changes sensitively via optical molecular imaging. The above findings suggest that the probes we designed could act as ideal and easy method for investigating the pivotal role of H + in lysosomes and are potential pH detectors in disease diagnosis through direct intracellular imaging. - Highlights: • Two probes for sensitively and selectively monitoring weak acidic pH change. • The pKa of the probes was highly suitable for staining lysosomes in tumor cells. • The properties of those probes were changed by different conjugate system. • These probes have negligible cytotoxicity and good sensitivity in vivo.

  13. Omega-3 fatty acid therapy dose-dependently and significantly decreased triglycerides and improved flow-mediated dilation, however, did not significantly improve insulin sensitivity in patients with hypertriglyceridemia.

    Science.gov (United States)

    Oh, Pyung Chun; Koh, Kwang Kon; Sakuma, Ichiro; Lim, Soo; Lee, Yonghee; Lee, Seungik; Lee, Kyounghoon; Han, Seung Hwan; Shin, Eak Kyun

    2014-10-20

    Experimental studies demonstrate that higher intake of omega-3 fatty acids (n-3 FA) improves insulin sensitivity, however, we reported that n-3 FA 2g therapy, most commonly used dosage did not significantly improve insulin sensitivity despite reducing triglycerides by 21% in patients. Therefore, we investigated the effects of different dosages of n-3 FA in patients with hypertriglyceridemia. This was a randomized, single-blind, placebo-controlled, parallel study. Age, sex, and body mass index were matched among groups. All patients were recommended to maintain a low fat diet. Forty-four patients (about 18 had metabolic syndrome/type 2 diabetes mellitus) in each group were given placebo, n-3 FA 1 (O1), 2 (O2), or 4 g (O4), respectively daily for 2 months. n-3 FA therapy dose-dependently and significantly decreased triglycerides and triglycerides/HDL cholesterol and improved flow-mediated dilation, compared with placebo (by ANOVA). However, each n-3 FA therapy did not significantly decrease high-sensitivity C-reactive protein and fibrinogen, compared with placebo. O1 significantly increased insulin levels and decreased insulin sensitivity (determined by QUICKI) and O2 significantly decreased plasma adiponectin levels relative to baseline measurements. Of note, when compared with placebo, each n-3 FA therapy did not significantly change insulin, glucose, adiponectin, glycated hemoglobin levels and insulin sensitivity (by ANOVA). We observed similar results in a subgroup of patients with the metabolic syndrome. n-3 FA therapy dose-dependently and significantly decreased triglycerides and improved flow-mediated dilation. Nonetheless, n-3 FA therapy did not significantly improve acute-phase reactants and insulin sensitivity in patients with hypertriglyceridemia, regardless of dosages. Copyright © 2014. Published by Elsevier Ireland Ltd.

  14. Improvement of sensitivity in high-resolution Rutherford backscattering spectroscopy

    International Nuclear Information System (INIS)

    Hashimoto, H.; Nakajima, K.; Suzuki, M.; Kimura, K.; Sasakawa, K.

    2011-01-01

    The sensitivity (limit of detection) of high-resolution Rutherford backscattering spectroscopy (HRBS) is mainly determined by the background noise of the spectrometer. There are two major origins of the background noise in HRBS, one is the stray ions scattered from the inner wall of the vacuum chamber of the spectrometer and the other is the dark noise of the microchannel plate (MCP) detector which is commonly used as a focal plane detector of the spectrometer in HRBS. In order to reject the stray ions, several barriers are installed inside the spectrometer and a thin Mylar foil is mounted in front of the detector. The dark noise of the MCP detector is rejected by the coincidence measurement with the secondary electrons emitted from the Mylar foil upon the ion passage. After these improvements, the background noise is reduced by a factor of 200 at a maximum. The detection limit can be improved down to 10 ppm for As in Si at a measurement time of 1 h under ideal conditions.

  15. High intensity interval training improves liver and adipose tissue insulin sensitivity

    Science.gov (United States)

    Marcinko, Katarina; Sikkema, Sarah R.; Samaan, M. Constantine; Kemp, Bruce E.; Fullerton, Morgan D.; Steinberg, Gregory R.

    2015-01-01

    Objective Endurance exercise training reduces insulin resistance, adipose tissue inflammation and non-alcoholic fatty liver disease (NAFLD), an effect often associated with modest weight loss. Recent studies have indicated that high-intensity interval training (HIIT) lowers blood glucose in individuals with type 2 diabetes independently of weight loss; however, the organs affected and mechanisms mediating the glucose lowering effects are not known. Intense exercise increases phosphorylation and inhibition of acetyl-CoA carboxylase (ACC) by AMP-activated protein kinase (AMPK) in muscle, adipose tissue and liver. AMPK and ACC are key enzymes regulating fatty acid metabolism, liver fat content, adipose tissue inflammation and insulin sensitivity but the importance of this pathway in regulating insulin sensitivity with HIIT is unknown. Methods In the current study, the effects of 6 weeks of HIIT were examined using obese mice with serine–alanine knock-in mutations on the AMPK phosphorylation sites of ACC1 and ACC2 (AccDKI) or wild-type (WT) controls. Results HIIT lowered blood glucose and increased exercise capacity, food intake, basal activity levels, carbohydrate oxidation and liver and adipose tissue insulin sensitivity in HFD-fed WT and AccDKI mice. These changes occurred independently of weight loss or reductions in adiposity, inflammation and liver lipid content. Conclusions These data indicate that HIIT lowers blood glucose levels by improving adipose and liver insulin sensitivity independently of changes in adiposity, adipose tissue inflammation, liver lipid content or AMPK phosphorylation of ACC. PMID:26909307

  16. Improvement technique of sensitized HAZ by GTAW cladding applied to a BWR power plant

    International Nuclear Information System (INIS)

    Tujimura, Hiroshi; Tamai, Yasumasa; Furukawa, Hideyasu; Kurosawa, Kouichi; Chiba, Isao; Nomura, Keiichi.

    1995-01-01

    A SCC(Stress Corrosion Cracking)-resistant technique, in which the sleeve installed by expansion is melted by GTAW process without filler metal with outside water cooling, was developed. The technique was applied to ICM (In-Core Monitor) housings of a BWR power plant in 1993. The ICM housings of which materials are type 304 Stainless Steels are sensitized with high tensile residual stresses by welding to the RPV (Reactor Pressure Vessel). As the result, ICM housings have potential of SCC initiation. Therefore, the improvement technique resistant to SCC was needed. The technique can improve chemical composition of the housing inside and residual stresses of the housing outside at the same time. Sensitization of the housing inner surface area is eliminated by replacing low-carbon with proper-ferrite microstructure clad. High tensile residual stresses of housing outside surface area is improved into compressive side. Compressive stresses of outside surface are induced by thermal stresses which are caused by inside cladding with outside water cooling. The clad is required to be low-carbon metal with proper ferrite and not to have the new sensitized HAZ (Heat Affected Zone) on the surface by cladding. The effect of the technique was qualified by SCC test, chemical composition check, ferrite content measurement and residual stresses measurement etc. All equipment for remote application were developed and qualified, too. The technique was successfully applied to a BWR plant after sufficient training

  17. Dichoptic training improves contrast sensitivity in adults with amblyopia.

    Science.gov (United States)

    Li, Jinrong; Spiegel, Daniel P; Hess, Robert F; Chen, Zidong; Chan, Lily Y L; Deng, Daming; Yu, Minbin; Thompson, Benjamin

    2015-09-01

    Dichoptic training is designed to promote binocular vision in patients with amblyopia. Initial studies have found that the training effects transfer to both binocular (stereopsis) and monocular (recognition acuity) visual functions. The aim of this study was to assess whether dichoptic training effects also transfer to contrast sensitivity (CS) in adults with amblyopia. We analyzed CS data from 30 adults who had taken part in one of two previous dichoptic training studies and assessed whether the changes in CS exceeded the 95% confidence intervals for change based on test-retest data from a separate group of observers with amblyopia. CS was measured using Gabor patches (0.5, 3 and 10cpd) before and after 10days of dichoptic training. Training was delivered using a dichoptic video game viewed through video goggles (n=15) or on an iPod touch equipped with a lenticular overlay screen (n=15). In the iPod touch study, training was combined with anodal transcranial direct current stimulation of the visual cortex. We found that dichoptic training significantly improved CS across all spatial frequencies tested for both groups. These results suggest that dichoptic training modifies the sensitivity of the neural systems that underpin monocular CS. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Solid Catalyst with Ionic Liquid Layer (SCILL). A concept to improve the selectivity of selective hydrogenations

    Energy Technology Data Exchange (ETDEWEB)

    Jess, A.; Korth, W. [Bayreuth Univ. (Germany). Chair of Chemical Engineering

    2011-07-01

    Catalytic hydrogenations are important for refinery processes, petrochemical applications as well as for numerous processes of the fine chemicals industry. In some cases, hydrogenations consist of a sequence of consecutive reactions, and the desired product is the intermediate. An important goal is then a high yield and selectivity to the intermediate, if possible at a high conversion degree. The selectivity to an intermediate primarily depends on the chemical nature of the catalyst, but may also be influenced by diffusion processes. Ionic liquids (ILs) are low melting salts (< 100 C) and represent a promising solvent class. This paper focuses on the concept of a Solid Catalyst with Ionic Liquid Layer (SCILL), where the solid catalyst is coated with a thin IL layer to improve the selectivity. (orig.)

  19. Wind scatterometry with improved ambiguity selection and rain modeling

    Science.gov (United States)

    Draper, David Willis

    Although generally accurate, the quality of SeaWinds on QuikSCAT scatterometer ocean vector winds is compromised by certain natural phenomena and retrieval algorithm limitations. This dissertation addresses three main contributors to scatterometer estimate error: poor ambiguity selection, estimate uncertainty at low wind speeds, and rain corruption. A quality assurance (QA) analysis performed on SeaWinds data suggests that about 5% of SeaWinds data contain ambiguity selection errors and that scatterometer estimation error is correlated with low wind speeds and rain events. Ambiguity selection errors are partly due to the "nudging" step (initialization from outside data). A sophisticated new non-nudging ambiguity selection approach produces generally more consistent wind than the nudging method in moderate wind conditions. The non-nudging method selects 93% of the same ambiguities as the nudged data, validating both techniques, and indicating that ambiguity selection can be accomplished without nudging. Variability at low wind speeds is analyzed using tower-mounted scatterometer data. According to theory, below a threshold wind speed, the wind fails to generate the surface roughness necessary for wind measurement. A simple analysis suggests the existence of the threshold in much of the tower-mounted scatterometer data. However, the backscatter does not "go to zero" beneath the threshold in an uncontrolled environment as theory suggests, but rather has a mean drop and higher variability below the threshold. Rain is the largest weather-related contributor to scatterometer error, affecting approximately 4% to 10% of SeaWinds data. A simple model formed via comparison of co-located TRMM PR and SeaWinds measurements characterizes the average effect of rain on SeaWinds backscatter. The model is generally accurate to within 3 dB over the tropics. The rain/wind backscatter model is used to simultaneously retrieve wind and rain from SeaWinds measurements. The simultaneous

  20. Sensitivity functions for uncertainty analysis: Sensitivity and uncertainty analysis of reactor performance parameters

    International Nuclear Information System (INIS)

    Greenspan, E.

    1982-01-01

    This chapter presents the mathematical basis for sensitivity functions, discusses their physical meaning and information they contain, and clarifies a number of issues concerning their application, including the definition of group sensitivities, the selection of sensitivity functions to be included in the analysis, and limitations of sensitivity theory. Examines the theoretical foundation; criticality reset sensitivities; group sensitivities and uncertainties; selection of sensitivities included in the analysis; and other uses and limitations of sensitivity functions. Gives the theoretical formulation of sensitivity functions pertaining to ''as-built'' designs for performance parameters of the form of ratios of linear flux functionals (such as reaction-rate ratios), linear adjoint functionals, bilinear functions (such as reactivity worth ratios), and for reactor reactivity. Offers a consistent procedure for reducing energy-dependent or fine-group sensitivities and uncertainties to broad group sensitivities and uncertainties. Provides illustrations of sensitivity functions as well as references to available compilations of such functions and of total sensitivities. Indicates limitations of sensitivity theory originating from the fact that this theory is based on a first-order perturbation theory

  1. Selective sensitivity enhancement in FT-NMR

    International Nuclear Information System (INIS)

    Farrar, T.C.

    1987-01-01

    In this article the basic two-spin nuclear magnetic resonance (NMR) experiment and the new sensitivity enhancement experiments are reviewed. In part two of this two-part series an overview of two-dimensional NMR experiments will be presented. Part two will appear in the June 1 issue of Analytical Chemistry

  2. Optimized Policies for Improving Fairness of Location-based Relay Selection

    DEFF Research Database (Denmark)

    Nielsen, Jimmy Jessen; Olsen, Rasmus Løvenstein; Madsen, Tatiana Kozlova

    2013-01-01

    For WLAN systems in which relaying is used to improve throughput performance for nodes located at the cell edge, node mobility and information collection delays can have a significant impact on the performance of a relay selection scheme. In this paper we extend our existing Markov Chain modeling...... framework for relay selection to allow for efficient calculation of relay policies given either mean throughput or kth throughput percentile as optimization criterium. In a scenario with static access point, static relay, and a mobile destination node, the kth throughput percentile optimization...

  3. Yellow filters can improve magnocellular function: motion sensitivity, convergence, accommodation, and reading.

    Science.gov (United States)

    Ray, N J; Fowler, S; Stein, J F

    2005-04-01

    The magnocellular system plays an important role in visual motion processing, controlling vergence eye movements, and in reading. Yellow filters may boost magnocellular activity by eliminating inhibitory blue input to this pathway. It was found that wearing yellow filters increased motion sensitivity, convergence, and accommodation in many children with reading difficulties, both immediately and after three months using the filters. Motion sensitivity was not increased using control neutral density filters. Moreover, reading-impaired children showed significant gains in reading ability after three months wearing the filters compared with those who had used a placebo. It was concluded that yellow filters can improve magnocellular function permanently. Hence, they should be considered as an alternative to corrective lenses, prisms, or exercises for treating poor convergence and accommodation, and also as an aid for children with reading problems.

  4. On the possibility of improving the sensitivity of dark-matter detection

    Energy Technology Data Exchange (ETDEWEB)

    Paschos, E.A.; Pilaftsis, A. (Dortmund Univ. (Germany, F.R.). Inst. fuer Physik); Zioutas, K. (Thessaloniki Univ. (Greece). Nuclear and Elementary Particle Physics Section)

    1990-02-22

    First we investigate the detectability of nuclear magnetic transitions produced by dark-matter particles. The M1 transitions are mediated by spin-dependent interactions between dark matter and nuclei. We assume that the dark matter consists mainly of photinos, and show that the expected rate is of the order of 1 event/kg/d for the excitation of nuclear magnetic states accompanied also by a recoiling nucleus. The de-excitation decay that follows, {approx equal} (ms-{mu}s), might later be observed as electromagnetic radiation in the GHz region in future, more sensitive, microwave devices. Secondly, we propose to utilize liquid-xenon detectors for measuring the energy of the recoiling nucleus, either through the Xe odd-isotopes or through other mixed atoms, such as hydrogen, with lowest masses. Furthermore the mass scale of these calorimeters (1-100 t) gives a greatly improved sensitivity for darkmatter detection compared with other conventional systems. (orig.).

  5. Auditory-somatosensory temporal sensitivity improves when the somatosensory event is caused by voluntary body movement

    Directory of Open Access Journals (Sweden)

    Norimichi Kitagawa

    2016-12-01

    Full Text Available When we actively interact with the environment, it is crucial that we perceive a precise temporal relationship between our own actions and sensory effects to guide our body movements.Thus, we hypothesized that voluntary movements improve perceptual sensitivity to the temporal disparity between auditory and movement-related somatosensory events compared to when they are delivered passively to sensory receptors. In the voluntary condition, participants voluntarily tapped a button, and a noise burst was presented at various onset asynchronies relative to the button press. The participants made either 'sound-first' or 'touch-first' responses. We found that the performance of temporal order judgment (TOJ in the voluntary condition (as indexed by the just noticeable difference was significantly better (M=42.5 ms ±3.8 s.e.m than that when their finger was passively stimulated (passive condition: M=66.8 ms ±6.3 s.e.m. We further examined whether the performance improvement with voluntary action can be attributed to the prediction of the timing of the stimulation from sensory cues (sensory-based prediction, kinesthetic cues contained in voluntary action, and/or to the prediction of stimulation timing from the efference copy of the motor command (motor-based prediction. When the participant’s finger was moved passively to press the button (involuntary condition and when three noise bursts were presented before the target burst with regular intervals (predictable condition, the TOJ performance was not improved from that in the passive condition. These results suggest that the improvement in sensitivity to temporal disparity between somatosensory and auditory events caused by the voluntary action cannot be attributed to sensory-based prediction and kinesthetic cues. Rather, the prediction from the efference copy of the motor command would be crucial for improving the temporal sensitivity.

  6. Escape windows to improve the size selectivity in the Baltic cod trawl fishery

    DEFF Research Database (Denmark)

    Madsen, Niels; Holst, René; Foldager, L.

    2002-01-01

    A rapid decrease of the stock of Baltic cod (Gadus morhua) has provided the incentive to improve the size selectivity in the trawl fishery. Use of escape windows is permitted in the legislation to give means of improving the size selectivity of cod as an alternative to a traditional standard codend....... The history of the use of escape windows in the Baltic Sea cod fishery is reviewed. The present escape windows do not function optimally. The objective of this new experiment was to compare an improved design of escape window, which is placed in the upper panel, with that of standard codend. Three standard...... of the codend selectivity was formulated to analyse the results and determine the effects of codend type, mesh size and other recorded variables. L50 and SR increased significantly with the mesh size. L50 was significantly increased and SR significantly reduced for a window codend with the same window mesh size...

  7. Zeolite-like Metal–Organic Framework (MOF) Encaged Pt(II)-Porphyrin for Anion-Selective Sensing

    KAUST Repository

    Masih, Dilshad; Chernikova, Valeriya; Shekhah, Osama; Eddaoudi, Mohamed; Mohammed, Omar F.

    2018-01-01

    The selectivity and sensitivity of sensors are of great interest to the materials chemistry community, and a lot of effort is now devoted to improving these characteristics. More specifically, the selective sensing of anions is one of the largest

  8. Selective and sensitive determination of lactose in low-lactose dairy products with HPAEC-PAD.

    Science.gov (United States)

    van Scheppingen, Wibo B; van Hilten, Piet H; Vijverberg, Marieke P; Duchateau, Alexander L L

    2017-08-15

    The demand for low lactose dairy products is increasing and more different lactose free food is commercially available. The level of lactose in these products decreased during the last years and nowadays a concentration of lactose free". For the determination of the lactose concentrations in these dairy products a sensitive analysis method is needed. We developed a method for the determination of low concentrations of lactose in a wide range of dairy products. A simple sample preparation with dilution, centrifugation and ultrafiltration is efficient for the isolation of lactose from the sample matrix. In this paper, a new HPAEC-PAD analysis on a CarboPac PA100 column gives a good separation of lactose from the other saccharides. This separation in combination with the PAD detector yields a selective and sensitive method for the quantification at the desired concentrations of lactose in low lactose dairy products. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Calcineurin inhibitors acutely improve insulin sensitivity without affecting insulin secretion in healthy human volunteers

    DEFF Research Database (Denmark)

    Øzbay, Aygen; Møller, Niels; Juhl, Claus

    2012-01-01

    and tacrolimus has been attributed to both beta cell dysfunction and impaired insulin sensitivity. WHAT THIS STUDY ADDS: This is the first trial to investigate beta cell function and insulin sensitivity using gold standard methodology in healthy human volunteers treated with clinically relevant doses...... of ciclosporin and tacrolimus. We document that both drugs acutely increase insulin sensitivity, while first phase and pulsatile insulin secretion remain unaffected. This study demonstrates that ciclosporin and tacrolimus have similar acute effects on glucose metabolism in healthy humans. AIM The introduction...... of calcineurin inhibitors (CNIs) ciclosporin (CsA) and tacrolimus (Tac) has improved the outcome of organ transplants, but complications such as new onset diabetes mellitus after transplantation (NODAT) cause impairment of survival rates. The relative contribution of each CNI to the pathogenesis and development...

  10. Potentially three distinct roles for hypoxic cell sensitizers in the clinic

    International Nuclear Information System (INIS)

    Chapman, J.D.; Raleigh, J.A.; Pedersen, J.E.; Ngan, J.; Shum, F.Y.

    1979-01-01

    Nitroaromatic drugs have been applied to radiation therapy on the basis of their effectiveness to enhance radiation damages selectively in hypoxic mammalian cells at nontoxic concentration. Such sensitizers could improve the rate of local tumor control by conventional radiotherapy in such cases that the resistance due to hypoxia in a limiting factor. The selective cytotoxicity of the drug to hypoxic cells is the second distinct action. A third potential role for nitroaromatic drugs could involve their use for the diagnosis of the number and location of hypoxic cells within tumors. The gain in therapeutic ratio by a factor from 5 to 10 is necessary before the full clinical impact of hypoxic cell radiosensitizers can be evaluated. The drugs selected for the use as clinical radiosensitizers were originally developed as the antibacterial agents with selective activity against anaerobes. The hypoxic cells in tumors are usually resistant to chemotherapy as well as resistant to radiation, and this specific drug action of sensitizers combined with that of an agent effective against oxygenated and cycling cells could possibly produce improved tumor cures. Electron-affinitive chemicals become selectively bound to the macromolecules of hypoxic mammalian cells by radiation-induced chemical reaction. This technique was used to identify by autoradiographic procedures the location of the radioactive nitrofurazone bound to hypoxic cells within multicellular spheroids. (Yamashita, S.)

  11. Polypyrrole Composite Film for Highly Sensitive and Selective Electrochemical Determination Sensors

    International Nuclear Information System (INIS)

    Zheng, Xiangli; Tian, Dong; Duan, Shuo; Wei, Maochao; Liu, Shan; Zhou, Changli; Li, Qing; Wu, Gang

    2014-01-01

    In this paper, polypyrrole (PPy) and benz[a]anthracene-7,12-dione (BaD) were electro-polymerized onto a pyrolytic graphite electrode (PGE), constructing a novel BaD/PPy/PGE platform for electrochemical sensoring. The morphology and electrochemical properties of the fabricated BaD/PPy/PGE were characterized by scanning electron microscopy, cyclic voltammetry and electrochemical impedance spectroscopy. Furthermore, the electrochemical behavior of benzo[k]fluoranthene (BkF) at the BaD/PPy/PGE was investigated. Due to the specific interactions between BkF and BaD, a wide linear range of BkF detection from 1.0 × 10 −12 to 1.0 × 10 −9 M with good linearity (R 2 = 0.9962) and a low detection limit (1.0 × 10 −13 M, S/N = 3) were demonstrated. Importantly, other similar aromatics which had one ring or more than two rings, such as benzo[a]anthracene, benzo[a]pyrene, pyrene, benzo[ghi]peryle, anthracene, phenanthrene, naphthalene and parachlorophenol, showed insignificant interference on BkF detection. Consequently, this novel BaD/PPy/PGE with excellent stability and selectivity holds promise as an effective BkF electrochemical sensor in aqueous solution. As an example for its practical application, the newly developed sensor was applied to quantitative determination of BkF in waste water samples obtained from a coking plant with satisfactory sensitivity, selectivity, and reversibility

  12. A Novel Piezoresistive Accelerometer with SPBs to Improve the Tradeoff between the Sensitivity and the Resonant Frequency.

    Science.gov (United States)

    Xu, Yu; Zhao, Libo; Jiang, Zhuangde; Ding, Jianjun; Peng, Niancai; Zhao, Yulong

    2016-02-06

    For improving the tradeoff between the sensitivity and the resonant frequency of piezoresistive accelerometers, the dependency between the stress of the piezoresistor and the displacement of the structure is taken into consideration in this paper. In order to weaken the dependency, a novel structure with suspended piezoresistive beams (SPBs) is designed, and a theoretical model is established for calculating the location of SPBs, the stress of SPBs and the resonant frequency of the whole structure. Finite element method (FEM) simulations, comparative simulations and experiments are carried out to verify the good agreement with the theoretical model. It is demonstrated that increasing the sensitivity greatly without sacrificing the resonant frequency is possible in the piezoresistive accelerometer design. Therefore, the proposed structure with SPBs is potentially a novel option for improving the tradeoff between the sensitivity and the resonant frequency of piezoresistive accelerometers.

  13. Improved Titanium Billet Inspection Sensitivity through Optimized Phased Array Design, Part II: Experimental Validation and Comparative Study with Multizone

    International Nuclear Information System (INIS)

    Hassan, W.; Vensel, F.; Knowles, B.; Lupien, V.

    2006-01-01

    The inspection of critical rotating components of aircraft engines has made important advances over the last decade. The development of Phased Array (PA) inspection capability for billet and forging materials used in the manufacturing of critical engine rotating components has been a priority for Honeywell Aerospace. The demonstration of improved PA inspection system sensitivity over what is currently used at the inspection houses is a critical step in the development of this technology and its introduction to the supply base as a production inspection. As described in Part I (in these proceedings), a new phased array transducer was designed and manufactured for optimal inspection of eight inch diameter Ti-6Al-4V billets. After confirming that the transducer was manufactured in accordance with the design specifications a validation study was conducted to assess the sensitivity improvement of the PAI over the current capability of Multi-zone (MZ) inspection. The results of this study confirm the significant (≅ 6 dB in FBH number sign sensitivity) improvement of the PAI sensitivity over that of MZI

  14. Adaptation improves face trustworthiness discrimination

    Directory of Open Access Journals (Sweden)

    Bruce D Keefe

    2013-06-01

    Full Text Available Adaptation to facial characteristics, such as gender and viewpoint, has been shown to both bias our perception of faces and improve facial discrimination. In this study, we examined whether adapting to two levels of face trustworthiness improved sensitivity around the adapted level. Facial trustworthiness was manipulated by morphing between trustworthy and untrustworthy prototypes, each generated by morphing eight trustworthy and eight untrustworthy faces respectively. In the first experiment, just-noticeable differences (JNDs were calculated for an untrustworthy face after participants adapted to an untrustworthy face, a trustworthy face, or did not adapt. In the second experiment, the three conditions were identical, except that JNDs were calculated for a trustworthy face. In the third experiment we examined whether adapting to an untrustworthy male face improved discrimination to an untrustworthy female face. In all experiments, participants completed a two-interval forced-choice adaptive staircase procedure, in which they judged which face was more untrustworthy. JNDs were derived from a psychometric function fitted to the data. Adaptation improved sensitivity to faces conveying the same level of trustworthiness when compared to no adaptation. When adapting to and discriminating around a different level of face trustworthiness there was no improvement in sensitivity and JNDs were equivalent to those in the no adaptation condition. The improvement in sensitivity was found to occur even when adapting to a face with different gender and identity. These results suggest that adaptation to facial trustworthiness can selectively enhance mechanisms underlying the coding of facial trustworthiness to improve perceptual sensitivity. These findings have implications for the role of our visual experience in the decisions we make about the trustworthiness of other individuals.

  15. Fabrication of highly sensitive and selective H{sub 2} gas sensor based on SnO{sub 2} thin film sensitized with microsized Pd islands

    Energy Technology Data Exchange (ETDEWEB)

    Van Toan, Nguyen; Viet Chien, Nguyen; Van Duy, Nguyen [International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology (HUST), No. 1, Dai Co Viet Road, Hanoi (Viet Nam); Si Hong, Hoang [School of Electrical Engineering (SEE), Hanoi University of Science and Technology (HUST), Hanoi (Viet Nam); Nguyen, Hugo [Division of Microsystems Technology, Department of Engineering Sciences, Uppsala University, 75237 Uppsala (Sweden); Duc Hoa, Nguyen [International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology (HUST), No. 1, Dai Co Viet Road, Hanoi (Viet Nam); Van Hieu, Nguyen, E-mail: hieu@itims.edu.vn [International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology (HUST), No. 1, Dai Co Viet Road, Hanoi (Viet Nam)

    2016-01-15

    Highlights: • H{sub 2} gas sensors based on SnO{sub 2} thin film sensitized with Pd islands were fabricated. • The sensors could monitor hazardous H{sub 2}n gas at low concentrations of 25–250 ppm. • H{sub 2} response of Pd/SnO{sub 2} is higher than that of Pt/SnO{sub 2} and Au/SnO{sub 2} sensors. • Enhancement of sensor performance was discussed based on spillover and diffusion mechanisms. - Abstract: Ultrasensitive and selective hydrogen gas sensor is vital component in safe use of hydrogen that requires a detection and alarm of leakage. Herein, we fabricated a H{sub 2} sensing devices by adopting a simple design of planar-type structure sensor in which the heater, electrode, and sensing layer were patterned on the front side of a silicon wafer. The SnO{sub 2} thin film-based sensors that were sensitized with microsized Pd islands were fabricated at a wafer-scale by using a sputtering system combined with micro-electronic techniques. The thicknesses of SnO{sub 2} thin film and microsized Pd islands were optimized to maximize the sensing performance of the devices. The optimized sensor could be used for monitoring hydrogen gas at low concentrations of 25–250 ppm, with a linear dependence to H{sub 2} concentration and a fast response and recovery time. The sensor also showed excellent selectivity for monitoring H{sub 2} among other gases, such as CO, NH{sub 3}, and LPG, and satisfactory characteristics for ensuring safety in handling hydrogen. The hydrogen sensing characteristics of the sensors sensitized with Pt and Au islands were also studied to clarify the sensing mechanisms.

  16. Spectroelectrochemistry as a Strategy for Improving Selectivity of Sensors for Security and Defense Applications

    Energy Technology Data Exchange (ETDEWEB)

    Heineman, William R.; Seliskar, Carl J.; Morris, Laura K.; Bryan, Samuel A.

    2012-12-19

    Spectroelectrochemistry provides improved selectivity for sensors by electrochemically modulating the optical signal associated with the analyte. The sensor consists of an optically transparent electrode (OTE) coated with a film that preconcentrates the target analyte. The OTE functions as an optical waveguide for attenuated total reflectance (ATR) spectroscopy, which detects the analyte by absorption. Alternatively, the OTE can serve as the excitation light for fluorescence detection, which is generally more sensitive than absorption. The analyte partitions into the film, undergoes an electrochemical redox reaction at the OTE surface, and absorbs or emits light in its oxidized or reduced state. The change in the optical response associated with electrochemical oxidation or reduction at the OTE is used to quantify the analyte. Absorption sensors for metal ion complexes such as [Fe(CN)6]4- and [Ru(bpy)3]2+ and fluorescence sensors for [Ru(bpy)3]2+ and the polycyclic aromatic hydrocarbon 1-hydroxypyrene have been developed. The sensor concept has been extended to binding assays for a protein using avidin–biotin and 17β-estradiol–anti-estradiol antibodies. The sensor has been demonstrated to measure metal complexes in complex samples such as nuclear waste and natural water. This sensor has qualities needed for security and defense applications that require a high level of selectivity and good detection limits for target analytes in complex samples. Quickly monitoring and designating intent of a nuclear program by measuring the Ru/Tc fission product ratio is such an application.

  17. The use of vector bootstrapping to improve variable selection precision in Lasso models

    NARCIS (Netherlands)

    Laurin, C.; Boomsma, D.I.; Lubke, G.H.

    2016-01-01

    The Lasso is a shrinkage regression method that is widely used for variable selection in statistical genetics. Commonly, K-fold cross-validation is used to fit a Lasso model. This is sometimes followed by using bootstrap confidence intervals to improve precision in the resulting variable selections.

  18. A highly sensitive, selective and turn-off fluorescent sensor based on phenylamine-oligothiophene derivative for rapid detection of Hg{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Xingxing; Niu, Qingfen, E-mail: qf_niu1216@qlu.edu.cn; Li, Tianduo; Cui, Yuezhi; Zhang, Shanshan

    2016-07-15

    A fluorescent sensor based on phenylamine-oligothiophene derivative 3TEA was reported. This sensor showed highly selective and sensitive detection of Hg{sup 2+} ion in THF/H{sub 2}O (7/3, v/v) solution through fluorescence quenching. The detection was unaffected by other competitive metal ions. The detection limit was found to be as low as 3.952×10{sup −7} M estimated by the titration method. The recognition process is reversible and confirmed by EDTA experiment. The turn-off fluorescence behavior of mercury interaction with 3TEA has been found to be so fast that it can be used for its qualitative as well as quantitative estimation. - Highlights: • A highly sensitive and selective fluorescence chemosensor 3TEA was reported. • 3TEA features high sensitive with the detection limit for Hg{sup 2+} ions was as low as 3.952×10{sup −7} M. • 3TEA can detect Hg{sup 2+} ion on-line and in real time.

  19. Valley-selective optical Stark effect probed by Kerr rotation

    Science.gov (United States)

    LaMountain, Trevor; Bergeron, Hadallia; Balla, Itamar; Stanev, Teodor K.; Hersam, Mark C.; Stern, Nathaniel P.

    2018-01-01

    The ability to monitor and control distinct states is at the heart of emerging quantum technologies. The valley pseudospin in transition metal dichalcogenide (TMDC) monolayers is a promising degree of freedom for such control, with the optical Stark effect allowing for valley-selective manipulation of energy levels in WS2 and WSe2 using ultrafast optical pulses. Despite these advances, understanding of valley-sensitive optical Stark shifts in TMDCs has been limited by reflectance-based detection methods where the signal is small and prone to background effects. More sensitive polarization-based spectroscopy is required to better probe ultrafast Stark shifts for all-optical manipulation of valley energy levels. Here, we show time-resolved Kerr rotation to be a more sensitive probe of the valley-selective optical Stark effect in monolayer TMDCs. Compared to the established time-resolved reflectance methods, Kerr rotation is less sensitive to background effects. Kerr rotation provides a fivefold improvement in the signal-to-noise ratio of the Stark effect optical signal and a more precise estimate of the energy shift. This increased sensitivity allows for observation of an optical Stark shift in monolayer MoS2 that exhibits both valley and energy selectivity, demonstrating the promise of this method for investigating this effect in other layered materials and heterostructures.

  20. Some problems connected with boron determination by atomic absorption spectroscopy and the sensitivity improvement

    Directory of Open Access Journals (Sweden)

    JELENA J. SAVOVIC

    2001-08-01

    Full Text Available Two atomizers were compared: an N2O–C2H2 flame and a stabilized U-shaped DC arc with aerosol supply. Both the high plasma temperature and the reducing atmosphere obtained by acetylene addition to the argon stream substantially increase the sensitivity of boron determination by atomic absorption spectroscopy (AAS when the arc atomizer is used. The results were compared with those for silicon as a control element. The experimental characteristic concentrations for both elements were compared with the computed values. The experimentally obtained characteristic concentration for boron when using the arc atomizer was in better agreement with the calculated value. It was estimated that the influence of stable monoxide formation on the sensitivity for both elements was about the same, but reduction of analyte and formation of non-volatile carbide particles was more important for boron, which is the main reason for the low sensitivity of boron determination using a flame atomizer. The use of an arc atomizer suppresses this interference and significantly improves the sensitivity of the determination.

  1. Improvement of resistance to rust through recurrent selection in pearl millet

    Energy Technology Data Exchange (ETDEWEB)

    Tapsoba, H. [Univ. of Georgia, Athens, GA (United States); Wilson, J.P.; Hanna, W.W. [Univ. of Georgia Coastal Plain Experimental Station, Tifton, GA (United States)

    1997-04-01

    Two pearl millet [Pennisetum glaucum (L.) R.Br. = P. typhoides (Burm.) Staff & Hubb., P. americanum (L.) K. Schum.] bulk populations, Tift No. 2 and Tift No. 5, served as base populations for four cycles of recurrent selection against susceptibility to Puccinia substriata Ell. & Barth, var. indica Ramachar & Cumm. A bulk inoculum of the pathogen was used. The objectives were to evaluate the progress achieved regarding overall resistance to the pathogen in the field and resistance to different races of the pathogen, and also to evaluate changes in unselected traits. During selection, the frequency of rust resistant plants continuously increased from about 30% in each base population to more than 85% by the third cycle of selection in both populations. An average increase of about 21 and 18% per cycle was obtained in Tift No. 2 and Tift No. 5, respectively. A continuous increase of the frequency of plants resistant to some races of the pathogen was also obtained. In Tift No. 5, 80% of the plants were resistant to eight races by the third cycle of selection. The accumulation of resistance observed in the seedlings was manifested in the field, both in 1993 and 1994, by a reduction of the final rust severity from the base population to the fourth selection cycle of both populations. This improvement in resistance to the rust pathogen was accompanied by an increase in the frequency of plants resistant to Pyricularia grisea (Cooke) Sacc. only in Tift No. 2. Despite the improvement in the selected character, genetic variability for agronomic traits such as plant height, number of culms/plant, flowering date, and panicle length was successfully maintained within each population. 20 refs., 1 fig., 7 tabs.

  2. A fluorogenic molecular nanoprobe with an engineered internal environment for sensitive and selective detection of biological hydrogen sulfide.

    Science.gov (United States)

    Kim, Myung; Seo, Young Hun; Kim, Youngsun; Heo, Jeongyun; Jang, Woo-Dong; Sim, Sang Jun; Kim, Sehoon

    2017-02-14

    A nanoreactor approach based on the amphiphilic assembly of various molecules offers a chance to finely engineer the internal reaction medium to enable highly selective and sensitive detection of H 2 S in biological media, being useful for microscopic imaging of cellular processes and in vitro diagnostics with blood samples.

  3. Selection of Parasites with Diminished Drug Sensitivity by Amodiaquine-Containing Antimalarial Regimens in Uganda

    Science.gov (United States)

    Nawaz, Fatima; Nsobya, Samuel L.; Kiggundu, Moses; Joloba, Moses; Rosenthal, Philip J.

    2009-01-01

    Background Amodiaquine (AQ) is paired with artesunate (AS) or sulfadoxine-pyrimethamine (SP) in recommended antimalarial regimens. It is unclear how readily AQ resistance will be selected with combination chemotherapy. Methods We collected 61 Plasmodium falciparum samples from a cohort of Ugandan children randomized to treatment with AQ/SP, AS/AQ, or artemether-lumefantrine (AL) for uncomplicated malaria. In vitro sensitivity to monodesethylamodiaquine (MDAQ) was measured with a histidine rich protein-2-based ELISA, and potential resistance-mediating polymorphisms pfmdr-1were evaluated. Results Parasites from subjects previously treated with AQ/SP or AS/AQ within 12 weeks were less sensitive to MDAQ (n=18; mean IC50 62.9 nM; range 12.7–158.3 nM) than parasites from those not treated within 12 weeks (n=43; mean IC50 37.5 nM; range 6.3–184.7 nM; p=0.0085) or only those in the treatment arm that did not contain AQ (n=20; mean IC50 28.8 nM; range 6.3–121.8 nM; p=0.0042). The proportion of strains with polymorphisms expected to mediate diminished response to AQ (pfmdr-1 86Y and 1246Y) increased after prior AQ therapy, although differences were not significant. Conclusions Prior therapy selected for diminished response to MDAQ, suggesting that AQ-containing regimens may rapidly lose efficacy in Africa. The mechanism of diminished MDAQ response is not fully explained by known mutations in pfmdr-1. PMID:19905933

  4. A Novel Piezoresistive Accelerometer with SPBs to Improve the Tradeoff between the Sensitivity and the Resonant Frequency

    Directory of Open Access Journals (Sweden)

    Yu Xu

    2016-02-01

    Full Text Available For improving the tradeoff between the sensitivity and the resonant frequency of piezoresistive accelerometers, the dependency between the stress of the piezoresistor and the displacement of the structure is taken into consideration in this paper. In order to weaken the dependency, a novel structure with suspended piezoresistive beams (SPBs is designed, and a theoretical model is established for calculating the location of SPBs, the stress of SPBs and the resonant frequency of the whole structure. Finite element method (FEM simulations, comparative simulations and experiments are carried out to verify the good agreement with the theoretical model. It is demonstrated that increasing the sensitivity greatly without sacrificing the resonant frequency is possible in the piezoresistive accelerometer design. Therefore, the proposed structure with SPBs is potentially a novel option for improving the tradeoff between the sensitivity and the resonant frequency of piezoresistive accelerometers.

  5. Paclitaxel-loaded redox-sensitive nanoparticles based on hyaluronic acid-vitamin E succinate conjugates for improved lung cancer treatment.

    Science.gov (United States)

    Song, Yu; Cai, Han; Yin, Tingjie; Huo, Meirong; Ma, Ping; Zhou, Jianping; Lai, Wenfang

    2018-01-01

    Lung cancer is the primary cause of cancer-related death worldwide. A redox-sensitive nanocarrier system was developed for tumor-targeted drug delivery and sufficient drug release of the chemotherapeutic agent paclitaxel (PTX) for improved lung cancer treatment. The redox-sensitive nanocarrier system constructed from a hyaluronic acid-disulfide-vitamin E succinate (HA-SS-VES, HSV) conjugate was synthesized and PTX was loaded in the delivery system. The physicochemical properties of the HSV nanoparticles were characterized. The redox-sensitivity, tumor-targeting and intracellular drug release capability of the HSV nanoparticles were evaluated. Furthermore, in vitro and in vivo antitumor activity of the PTX-loaded HSV nanoparticles was investigated in a CD44 over-expressed A549 tumor model. This HSV conjugate was successfully synthesized and self-assembled to form nanoparticles in aqueous condition with a low critical micelle concentration of 36.3 μg mL -1 . Free PTX was successfully entrapped into the HSV nanoparticles with a high drug loading of 33.5% (w/w) and an entrapment efficiency of 90.6%. Moreover, the redox-sensitivity of the HSV nanoparticles was confirmed by particle size change of the nanoparticles along with in vitro release profiles in different reducing environment. In addition, the HA-receptor mediated endocytosis and the potency of redox-sensitivity for intracellular drug delivery were further verified by flow cytometry and confocal laser scanning microscopic analysis. The antitumor activity results showed that compared to redox-insensitive nanoparticles and Taxol ® , PTX-loaded redox-sensitive nanoparticles exhibited much greater in vitro cytotoxicity and apoptosis-inducing ability against CD44 over-expressed A549 tumor cells. In vivo, the PTX-loaded HSV nanoparticles possessed much higher antitumor efficacy in an A549 mouse xenograft model and demonstrated improved safety profile. In summary, our PTX-loaded redox-sensitive HSV nanoparticles

  6. Noise sensitivity of portfolio selection in constant conditional correlation GARCH models

    Science.gov (United States)

    Varga-Haszonits, I.; Kondor, I.

    2007-11-01

    This paper investigates the efficiency of minimum variance portfolio optimization for stock price movements following the Constant Conditional Correlation GARCH process proposed by Bollerslev. Simulations show that the quality of portfolio selection can be improved substantially by computing optimal portfolio weights from conditional covariances instead of unconditional ones. Measurement noise can be further reduced by applying some filtering method on the conditional correlation matrix (such as Random Matrix Theory based filtering). As an empirical support for the simulation results, the analysis is also carried out for a time series of S&P500 stock prices.

  7. Observations of Tunable Resistive Pulse Sensing for Exosome Analysis: Improving System Sensitivity and Stability.

    Science.gov (United States)

    Anderson, Will; Lane, Rebecca; Korbie, Darren; Trau, Matt

    2015-06-16

    Size distribution and concentration measurements of exosomes are essential when investigating their cellular function and uptake. Recently, a particle size distribution and concentration measurement platform known as tunable resistive pulse sensing (TRPS) has seen increased use for the characterization of exosome samples. TRPS measures the brief increase in electrical resistance (a resistive pulse) produced by individual submicrometer/nanoscale particles as they translocate through a size-tunable submicrometer/micrometer-sized pore, embedded in an elastic membrane. Unfortunately, TRPS measurements are susceptible to issues surrounding system stability, where the pore can become blocked by particles, and sensitivity issues, where particles are too small to be detected against the background noise of the system. Herein, we provide a comprehensive analysis of the parameters involved in TRPS exosome measurements and demonstrate the ability to improve system sensitivity and stability by the optimization of system parameters. We also provide the first analysis of system noise, sensitivity cutoff limits, and accuracy with respect to exosome measurements and offer an explicit definition of system sensitivity that indicates the smallest particle diameter that can be detected within the noise of the trans-membrane current. A comparison of exosome size measurements from both TRPS and cryo-electron microscopy is also provided, finding that a significant number of smaller exosomes fell below the detection limit of the TRPS platform and offering one potential insight as to why there is such large variability in the exosome size distribution reported in the literature. We believe the observations reported here may assist others in improving TRPS measurements for exosome samples and other submicrometer biological and nonbiological particles.

  8. Receiver sensitivity improvement in spectrally-efficient guard-band twin-SSB-OFDM using an optical IQ modulator

    Science.gov (United States)

    Chen, Ming; Peng, Miao; Zhou, Hui; Zheng, Zhiwei; Tang, Xionggui; Maivan, Lap

    2017-12-01

    To further improve receiver sensitivity of spectrally-efficient guard-band direct-detection optical orthogonal frequency-division multiplexing (OFDM) with twin single-side-band (SSB) modulation technique, an optical IQ modulator (IQM) is employed to optimize optical carrier-to-signal power ratio (CSPR). The CSPRs for the guard-band twin-SSB-OFDM signal generated by using dual-drive Mach-Zehnder modulator (DD-MZM) and optical IQM are theoretically analyzed and supported by simulations. The optimal CSPR for the two types of guard-band twin-SSB-OFDM are identified. The simulations exhibit that the error vector magnitude (EVM) performance of the IQM-enabled guard-band twin-SSB-OFDM is improved by more than 4-dB compared to that of the twin-SSB-OFDM enabled by DD-MZM after 80-km single-mode fiber (SMF) transmission. In addition, more than 3-dB and 10 dB receiver sensitivity improvements in terms of received optical power (ROP) and optical signal-to-noise ratio (OSNR) are also achieved, respectively.

  9. Monitoring and improving the sensitivity of dengue nested RT-PCR used in longitudinal surveillance in Thailand.

    Science.gov (United States)

    Klungthong, Chonticha; Manasatienkij, Wudtichai; Phonpakobsin, Thipwipha; Chinnawirotpisan, Piyawan; Rodpradit, Prinyada; Hussem, Kittinun; Thaisomboonsuk, Butsaya; Ong-ajchaowlerd, Prapapun; Nisalak, Ananda; Kalayanarooj, Siripen; Buddhari, Darunee; Gibbons, Robert V; Jarman, Richard G; Yoon, In-Kyu; Fernandez, Stefan

    2015-02-01

    AFRIMS longitudinal dengue surveillance in Thailand depends on the nested RT-PCR and the dengue IgM/IgG ELISA. To examine and improve the sensitivity of the nested RT-PCR using a panel of archived samples collected during dengue surveillance. A retrospective analysis of 16,454 dengue IgM/IgG ELISA positive cases collected between 2000 and 2013 was done to investigate the sensitivity of the nested RT-PCR. From these cases, 318 acute serum specimens or extracted RNA, previously found to be negative by the nested RT-PCR, were tested using TaqMan real-time RT-PCR (TaqMan rRT-PCR). To improve the sensitivity of nested RT-PCR, we designed a new primer based on nucleotide sequences from contemporary strains found to be positive by the TaqMan rRT-PCR. Sensitivity of the new nested PCR was calculated using a panel of 87 samples collected during 2011-2013. The percentage of dengue IgM/IgG ELISA positive cases that were negative by the nested RT-PCR varied from 17% to 42% for all serotypes depending on the year. Using TaqMan rRT-PCR, dengue RNA was detected in 194 (61%) of the 318 acute sera or extracted RNA previously found to be negative by the nested RT-PCR. The newly designed DENV-1 specific primer increased the sensitivity of DENV-1 detection by the nested RT-PCR from 48% to 88%, and of all 4 serotypes from 73% to 87%. These findings demonstrate the impact of genetic diversity and signal erosion on the sensitivity of PCR-based methods. Published by Elsevier B.V.

  10. Axial asymmetry for improved sensitivity in MEMS piezoresistors

    International Nuclear Information System (INIS)

    Shuvra, Pranoy Deb; McNamara, Shamus; Lin, Ji-Tzuoh; Alphenaar, Bruce; Walsh, Kevin; Davidson, Jim

    2016-01-01

    The strain induced resistance change is compared for asymmetric, symmetric and diffused piezoresistive elements. Finite element analysis is used to simulate the performance of a T-shaped piezoresistive MEMS cantilever, including a lumped parameter model to show the effect of geometric asymmetry on the piezoresistor sensitivity. Asymmetric piezoresistors are found to be much more sensitive to applied load than the typical symmetric design producing about two orders of magnitude higher resistance change. This is shown to be due to the difference in the stress distribution in the symmetric and asymmetric geometries resulting in less resistance change cancellation in the asymmetric design. Although still less sensitive than diffused piezoresistors, asymmetric piezoresistors are sensitive enough for many applications, and are much easier to fabricate and integrate into MEMS devices. (paper)

  11. Cell-specific and pH-sensitive nanostructure hydrogel based on chitosan as a photosensitizer carrier for selective photodynamic therapy.

    Science.gov (United States)

    Belali, Simin; Karimi, Ali Reza; Hadizadeh, Mahnaz

    2018-04-15

    The major problems of porphyrins as promising materials for photodynamic therapy (PDT) are their low solubility, subsequently aggregation in biological environments, and a lack of tumor selectivity. With this in mind, a chitosan-based hydrogel conjugated with tetrakis(4-aminophenyl)porphyrin (NH 2 -TPP) and 2,4,6-tris(p-formylphenoxy)-1,3,5-triazine (TRIPOD) via Schiff base linkage, functionalized with folate was designed and synthesized as a pH-sensitive, self-healable and injectable targeted PS delivery system. This new hydrogel was characterized by FT-IR, 1 H NMR, SEM, UV-vis, fluorescence spectroscopy and zeta potential. Formation of imine bonds with the aldehyde group of TRIPOD and amine group of NH 2 -TPP and chitosan, as a dynamic connection, was approved by rheological analysis. Spectroscopic characterizations revealed that aggregation of porphyrin in aqueous media was eliminated due to diminished π stacking interaction of porphyrin in 3D cross-linked hydrogel structure. Hydrogel 3D microporous structure efficiently transfers the excitation energy to the porphyrin unit, yielding improvement singlet oxygen releases. Cytotoxicity and phototoxicity analysis of the CS/NH 2 -TPP/FA hydrogels indicating an excellent capability to kill cancer cells selectively and prevent damage to normal cells. This work presents a new and efficient model for the preparation of highly efficient and targeting photosensitizer delivery system. Copyright © 2018. Published by Elsevier B.V.

  12. Supplier selection based on improved MOGA and its application in nuclear power equipment procurement

    International Nuclear Information System (INIS)

    Yan Zhaojun; Wang Dezhong; Zhou Lei

    2007-01-01

    Considering the fact that there are few objective and available methods supporting the supplier selection in nuclear power equipment purchasing process, a supplier selection method based on improved multi-objective genetic algorithm (MOGA) is proposed. The simulation results demonstrate the effectiveness and efficiency of this method for the supplier selection in nuclear power equipment procurement process. (authors)

  13. Electrostatic Dust Detector with Improved Sensitivity

    International Nuclear Information System (INIS)

    Boyle, D.P.; Skinner, C.H.; Roquemore, A.L.

    2008-01-01

    Methods to measure the inventory of dust particles and to remove dust if it approaches safety limits will be required in next-step tokamaks such as ITER. An electrostatic dust detector, based on a fine grid of interlocking circuit traces, biased to 30 or 50 V, has been developed for the detection of dust on remote surfaces in air and vacuum environments. Gaining operational experience of dust detection on surfaces in tokamaks is important, however the level of dust generated in contemporary short-pulse tokamaks is comparatively low and high sensitivity is necessary to measure dust on a shot-by-shot basis. We report on modifications in the detection electronics that have increased the sensitivity of the electrostatic dust detector by a factor of up to 120, - a level suitable for measurements on contemporary tokamaks.

  14. Could non-grade based selection improve medical student socio-demographic diversity?

    DEFF Research Database (Denmark)

    O'Neill, Lotte Dyhrberg

    2013-01-01

    selected with a non-grade-based or ’non-cognitive’ admission program. The two admission groups were compared on seven social indices (doctor parent, ethnic origin, father’s education, mother’s education, parenthood, parents live together, parent on benefit). Result: Selection strategy made no difference...... to the social diversity of admitted medical students. The non-cognitive admission program studied was not a useful initiative for improving medical student diversity nor did it further disadvantaged educationally vulnerable population groups in these cohorts. Discussion: The social heritage and general...

  15. Multiple model analysis with discriminatory data collection (MMA-DDC): A new method for improving measurement selection

    Science.gov (United States)

    Kikuchi, C.; Ferre, P. A.; Vrugt, J. A.

    2011-12-01

    Hydrologic models are developed, tested, and refined based on the ability of those models to explain available hydrologic data. The optimization of model performance based upon mismatch between model outputs and real world observations has been extensively studied. However, identification of plausible models is sensitive not only to the models themselves - including model structure and model parameters - but also to the location, timing, type, and number of observations used in model calibration. Therefore, careful selection of hydrologic observations has the potential to significantly improve the performance of hydrologic models. In this research, we seek to reduce prediction uncertainty through optimization of the data collection process. A new tool - multiple model analysis with discriminatory data collection (MMA-DDC) - was developed to address this challenge. In this approach, multiple hydrologic models are developed and treated as competing hypotheses. Potential new data are then evaluated on their ability to discriminate between competing hypotheses. MMA-DDC is well-suited for use in recursive mode, in which new observations are continuously used in the optimization of subsequent observations. This new approach was applied to a synthetic solute transport experiment, in which ranges of parameter values constitute the multiple hydrologic models, and model predictions are calculated using likelihood-weighted model averaging. MMA-DDC was used to determine the optimal location, timing, number, and type of new observations. From comparison with an exhaustive search of all possible observation sequences, we find that MMA-DDC consistently selects observations which lead to the highest reduction in model prediction uncertainty. We conclude that using MMA-DDC to evaluate potential observations may significantly improve the performance of hydrologic models while reducing the cost associated with collecting new data.

  16. Improved performance of silicon-nanoparticle film-coated dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Ravindra Kumar; Bedja, Idriss M. [CRC, Department of Optometry, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433 (Saudi Arabia); Aldwayyan, Abdullah Saleh [Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451 (Saudi Arabia)

    2012-11-15

    Silicon (Si) nanoparticles with average size of 13 nm and orange-red luminescence under UV absorption were synthesized using electrochemical etching of silicon wafers. A film of Si nanoparticles with thickness of 0.75 {mu}m to 2.6 {mu}m was coated on the glass (TiO{sub 2} side) of a dye-sensitized solar cell (DSSC). The cell exhibited nearly 9% enhancement in power conversion efficiency ({eta}) at film thickness of {proportional_to}2.4 {mu}m under solar irradiation of 100 mW/cm{sup 2} (AM 1.5) with improved fill factor and short-circuit current density. This study revealed for the first time that the Si-nanoparticle film converting UV into visible light and helping in homogeneous irradiation, can be utilized for improving the efficiency of the DSSCs. (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. Highly sensitive and selective determination of methylergometrine maleate using carbon nanofibers/silver nanoparticles composite modified carbon paste electrode.

    Science.gov (United States)

    Kalambate, Pramod K; Rawool, Chaitali R; Karna, Shashi P; Srivastava, Ashwini K

    2016-12-01

    A highly sensitive and selective voltammetric method for determination of Methylergometrine maleate (MM) in pharmaceutical formulations, urine and blood serum samples has been developed based on enhanced electrochemical response of MM at carbon nanofibers and silver nanoparticles modified carbon paste electrode (CNF-AgNP-CPE). The electrode material was characterized by various techniques viz., X-ray diffraction, scanning electron microscopy and energy dispersive X-ray spectroscopy. The electrocatalytic response of MM at CNF-AgNP-CPE was studied by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Under optimized conditions, the proposed sensor exhibits excellent electrochemical response towards MM. The DPV study shows greatly enhanced electrochemical signal for MM at CNF-AgNP-CPE lending high sensitivity to the proposed sensor for MM detection. The peak (Ip) current for MM is found to be rectilinear in the range 4.0×10(-8)-2.0×10(-5)M with a detection limit of 7.1×10(-9)M using DPV. The feasibility of the proposed sensor in analytical applications was investigated by conducting experiments on commercial pharmaceutical formulations, human urine and blood serum samples, which yielded satisfactory recoveries of MM. The proposed electrochemical sensor offers high sensitivity, selectivity, reproducibility and practical utility. We recommend it as an authentic and productive electrochemical sensor for successful determination of MM. Copyright © 2016. Published by Elsevier B.V.

  18. Improving detection sensitivity for partial discharge monitoring of high voltage equipment

    Science.gov (United States)

    Hao, L.; Lewin, P. L.; Swingler, S. G.

    2008-05-01

    Partial discharge (PD) measurements are an important technique for assessing the health of power apparatus. Previous published research by the authors has shown that an electro-optic system can be used for PD measurement of oil-filled power transformers. A PD signal generated within an oil-filled power transformer may reach a winding and then travel along the winding to the bushing core bar. The bushing, acting like a capacitor, can transfer the high frequency components of the partial discharge signal to its earthed tap point. Therefore, an effective PD current measurement can be implemented at the bushing tap by using a radio frequency current transducer around the bushing-tap earth connection. In addition, the use of an optical transmission technique not only improves the electrical noise immunity and provides the possibility of remote measurement but also realizes electrical isolation and enhances safety for operators. However, the bushing core bar can act as an aerial and in addition noise induced by the electro-optic modulation system may influence overall measurement sensitivity. This paper reports on a machine learning technique, namely the use of a support vector machine (SVM), to improve the detection sensitivity of the system. Comparison between the signal extraction performances of a passive hardware filter and the SVM technique has been assessed. The results obtained from the laboratory-based experiment have been analysed and indicate that the SVM approach provides better performance than the passive hardware filter and it can reliably detect discharge signals with apparent charge greater than 30 pC.

  19. Improving detection sensitivity for partial discharge monitoring of high voltage equipment

    International Nuclear Information System (INIS)

    Hao, L; Lewin, P L; Swingler, S G

    2008-01-01

    Partial discharge (PD) measurements are an important technique for assessing the health of power apparatus. Previous published research by the authors has shown that an electro-optic system can be used for PD measurement of oil-filled power transformers. A PD signal generated within an oil-filled power transformer may reach a winding and then travel along the winding to the bushing core bar. The bushing, acting like a capacitor, can transfer the high frequency components of the partial discharge signal to its earthed tap point. Therefore, an effective PD current measurement can be implemented at the bushing tap by using a radio frequency current transducer around the bushing-tap earth connection. In addition, the use of an optical transmission technique not only improves the electrical noise immunity and provides the possibility of remote measurement but also realizes electrical isolation and enhances safety for operators. However, the bushing core bar can act as an aerial and in addition noise induced by the electro-optic modulation system may influence overall measurement sensitivity. This paper reports on a machine learning technique, namely the use of a support vector machine (SVM), to improve the detection sensitivity of the system. Comparison between the signal extraction performances of a passive hardware filter and the SVM technique has been assessed. The results obtained from the laboratory-based experiment have been analysed and indicate that the SVM approach provides better performance than the passive hardware filter and it can reliably detect discharge signals with apparent charge greater than 30 pC

  20. Total adiponectin and adiponectin multimeric complexes in relation to weight loss-induced improvements in insulin sensitivity in obese women

    DEFF Research Database (Denmark)

    Polak, J.; Kovacova, Z.; Holst, C.

    2008-01-01

    , and LMW). The HMW form was suggested to be closely associated with insulin sensitivity. This study investigated whether diet-induced changes in insulin sensitivity were associated with changes in adiponectin multimeric complexes. SUBJECTS: Twenty obese women with highest and twenty obese women with lowest...... diet induced changes in insulin sensitivity (responders and non-responders respectively), matched for weight loss (body mass index (BMI)=34.5 (s.d. 2.9) resp. 36.5 kg/m(2) (s.d. 4.0) for responders and non-responders), were selected from 292 women who underwent a 10-week low-caloric diet (LCD; 600 kcal...

  1. An Improved Test Selection Optimization Model Based on Fault Ambiguity Group Isolation and Chaotic Discrete PSO

    Directory of Open Access Journals (Sweden)

    Xiaofeng Lv

    2018-01-01

    Full Text Available Sensor data-based test selection optimization is the basis for designing a test work, which ensures that the system is tested under the constraint of the conventional indexes such as fault detection rate (FDR and fault isolation rate (FIR. From the perspective of equipment maintenance support, the ambiguity isolation has a significant effect on the result of test selection. In this paper, an improved test selection optimization model is proposed by considering the ambiguity degree of fault isolation. In the new model, the fault test dependency matrix is adopted to model the correlation between the system fault and the test group. The objective function of the proposed model is minimizing the test cost with the constraint of FDR and FIR. The improved chaotic discrete particle swarm optimization (PSO algorithm is adopted to solve the improved test selection optimization model. The new test selection optimization model is more consistent with real complicated engineering systems. The experimental result verifies the effectiveness of the proposed method.

  2. Non-sensitized selective photochemical reduction of CO2 to CO under visible light with an iron molecular catalyst.

    Science.gov (United States)

    Rao, Heng; Bonin, Julien; Robert, Marc

    2017-03-02

    A substituted tetraphenyl iron porphyrin, bearing positively charged trimethylammonio groups at the para position of each phenyl ring, demonstrates its ability as a homogeneous molecular catalyst to selectively reduce CO 2 to CO under visible light irradiation in organic media without the assistance of a sensitizer and no competitive hydrogen evolution for several days.

  3. Endurance training improves insulin sensitivity and body composition in prostate cancer patients treated with androgen deprivation therapy.

    Science.gov (United States)

    Hvid, Thine; Winding, Kamilla; Rinnov, Anders; Dejgaard, Thomas; Thomsen, Carsten; Iversen, Peter; Brasso, Klaus; Mikines, Kari J; van Hall, Gerrit; Lindegaard, Birgitte; Solomon, Thomas P J; Pedersen, Bente K

    2013-10-01

    Insulin resistance and changes in body composition are side effects of androgen deprivation therapy (ADT) given to prostate cancer patients. The present study investigated whether endurance training improves insulin sensitivity and body composition in ADT-treated prostate cancer patients. Nine men undergoing ADT for prostate cancer and ten healthy men with normal testosterone levels underwent 12 weeks of endurance training. Primary endpoints were insulin sensitivity (euglycemic-hyperinsulinemic clamps with concomitant glucose-tracer infusion) and body composition (dual-energy X-ray absorptiometry and magnetic resonance imaging). The secondary endpoint was systemic inflammation. Statistical analysis was carried out using two-way ANOVA. Endurance training increased VO2max (ml(O2)/min per kg) by 11 and 13% in the patients and controls respectively (PBody weight (Pbody fat mass (FM) (Pbody mass (P=0.99) was unchanged. Additionally, reductions were observed in abdominal (Pcancer patients exhibited improved insulin sensitivity and body composition to a similar degree as eugonadal men.

  4. Origin and differential selection of allelic variation at TAS2R16 associated with salicin bitter taste sensitivity in Africa.

    Science.gov (United States)

    Campbell, Michael C; Ranciaro, Alessia; Zinshteyn, Daniel; Rawlings-Goss, Renata; Hirbo, Jibril; Thompson, Simon; Woldemeskel, Dawit; Froment, Alain; Rucker, Joseph B; Omar, Sabah A; Bodo, Jean-Marie; Nyambo, Thomas; Belay, Gurja; Drayna, Dennis; Breslin, Paul A S; Tishkoff, Sarah A

    2014-02-01

    Bitter taste perception influences human nutrition and health, and the genetic variation underlying this trait may play a role in disease susceptibility. To better understand the genetic architecture and patterns of phenotypic variability of bitter taste perception, we sequenced a 996 bp region, encompassing the coding exon of TAS2R16, a bitter taste receptor gene, in 595 individuals from 74 African populations and in 94 non-Africans from 11 populations. We also performed genotype-phenotype association analyses of threshold levels of sensitivity to salicin, a bitter anti-inflammatory compound, in 296 individuals from Central and East Africa. In addition, we characterized TAS2R16 mutants in vitro to investigate the effects of polymorphic loci identified at this locus on receptor function. Here, we report striking signatures of positive selection, including significant Fay and Wu's H statistics predominantly in East Africa, indicating strong local adaptation and greater genetic structure among African populations than expected under neutrality. Furthermore, we observed a "star-like" phylogeny for haplotypes with the derived allele at polymorphic site 516 associated with increased bitter taste perception that is consistent with a model of selection for "high-sensitivity" variation. In contrast, haplotypes carrying the "low-sensitivity" ancestral allele at site 516 showed evidence of strong purifying selection. We also demonstrated, for the first time, the functional effect of nonsynonymous variation at site 516 on salicin phenotypic variance in vivo in diverse Africans and showed that most other nonsynonymous substitutions have weak or no effect on cell surface expression in vitro, suggesting that one main polymorphism at TAS2R16 influences salicin recognition. Additionally, we detected geographic differences in levels of bitter taste perception in Africa not previously reported and infer an East African origin for high salicin sensitivity in human populations.

  5. The Improved Sensitivity to Crossmodal Asynchrony Caused by Voluntary Action: Comparing Combinations of Sensory Modalities

    Directory of Open Access Journals (Sweden)

    Norimichi Kitagawa

    2011-10-01

    Full Text Available The brain has to assess the fine temporal relationship between voluntary actions and their sensory effects to achieve precise spatiotemporal control of body movement. Recently we found that voluntary action improved the subsequent perceptual temporal discrimination between somatosensory and auditory events. In voluntary condition, participants actively pressed a button and a noise burst was presented at various onset asynchronies relative to the button press. The participants made either ‘sound-first’ or ‘touch-first’ responses. We found that the temporal order judgment performance in the voluntary condition (as indexed by just noticeable difference was significantly better than that when their finger was passively stimulated (passive condition. Temporal attention and comparable involuntary movement did not explain the improvement caused by the voluntary action. The results suggest that predicting sensory consequences via a ‘forward’ model enhances perceptual temporal resolution for precise control of the body. The present study examined whether this improved temporal sensitivity caused by the voluntary action is also observed for the other combinations of sensory modalities. We compared the effects of voluntary action on the temporal sensitivity between auditory-somatosensory, visual-somatosensory, and somatosensory-somatosensory stimulus pairs.

  6. Sensitivity Analysis of Centralized Dynamic Cell Selection

    DEFF Research Database (Denmark)

    Lopez, Victor Fernandez; Alvarez, Beatriz Soret; Pedersen, Klaus I.

    2016-01-01

    and a suboptimal optimization algorithm that nearly achieves the performance of the optimal Hungarian assignment. Moreover, an exhaustive sensitivity analysis with different network and traffic configurations is carried out in order to understand what conditions are more appropriate for the use of the proposed...

  7. Using Improved Entropy-Cloud Model to Select High-Speed Railway Express Freight Train Service Sites

    Directory of Open Access Journals (Sweden)

    Wencheng Huang

    2017-01-01

    Full Text Available High-speed railway (HSR express freight train service sites selection is critical to the development of China’s Third Party Logistics market. In this paper, we formulate an improved entropy-cloud model based approach to solve the HSR express sites selection problem for the first time. The basic data of the indicators, for example, existing railway network conditions, traffic environment, express freight market demand, and policy, will be used as the inputs. We apply improved entropy method to obtain each subindicator’s weight. The cloud model will be used to select and classify each station under evaluation.

  8. Projected large flood event sensitivity to projection selection and temporal downscaling methodology

    Energy Technology Data Exchange (ETDEWEB)

    Raff, D. [U.S. Dept. of the Interior, Bureau of Reclamation, Denver, Colorado (United States)

    2008-07-01

    Large flood events, that influence regulatory guidelines as well as safety of dams decisions, are likely to be affected by climate change. This talk will evaluate the use of climate projections downscaled and run through a rainfall - runoff model and its influence on large flood events. The climate spatial downscaling is performed statistically and a re-sampling and scaling methodology is used to temporally downscale from monthly to daily signals. The signals are run through a National Weather Service operational rainfall-runoff model to produce 6-hour flows. The flows will be evaluated for changes in large events at look-ahead horizons from 2011 - 2040, 2041 - 2070, and 2071 - 2099. The sensitivity of results will be evaluated with respect to projection selection criteria and re-sampling and scaling criteria for the Boise River in Idaho near Lucky Peak Dam. (author)

  9. Projected large flood event sensitivity to projection selection and temporal downscaling methodology

    International Nuclear Information System (INIS)

    Raff, D.

    2008-01-01

    Large flood events, that influence regulatory guidelines as well as safety of dams decisions, are likely to be affected by climate change. This talk will evaluate the use of climate projections downscaled and run through a rainfall - runoff model and its influence on large flood events. The climate spatial downscaling is performed statistically and a re-sampling and scaling methodology is used to temporally downscale from monthly to daily signals. The signals are run through a National Weather Service operational rainfall-runoff model to produce 6-hour flows. The flows will be evaluated for changes in large events at look-ahead horizons from 2011 - 2040, 2041 - 2070, and 2071 - 2099. The sensitivity of results will be evaluated with respect to projection selection criteria and re-sampling and scaling criteria for the Boise River in Idaho near Lucky Peak Dam. (author)

  10. Highly Sensitive Fluorescence Probe Based on Functional SBA-15 for Selective Detection of Hg2+

    Directory of Open Access Journals (Sweden)

    Wang Xiaoyu

    2010-01-01

    Full Text Available Abstract An inorganic–organic hybrid fluorescence chemosensor (DA/SBA-15 was prepared by covalent immobilization of a dansylamide derivative into the channels of mesoporous silica material SBA-15 via (3-aminopropyltriethoxysilane (APTES groups. The primary hexagonally ordered mesoporous structure of SBA-15 was preserved after the grafting procedure. Fluorescence characterization shows that the obtained inorganic–organic hybrid composite is highly selective and sensitive to Hg2+ detection, suggesting the possibility for real-time qualitative or quantitative detection of Hg2+ and the convenience for potential application in toxicology and environmental science.

  11. pH-sensitive polymeric nanoparticles to improve oral bioavailability of peptide/protein drugs and poorly water-soluble drugs.

    Science.gov (United States)

    Wang, Xue-Qing; Zhang, Qiang

    2012-10-01

    pH-sensitive polymeric nanoparticles are promising for oral drug delivery, especially for peptide/protein drugs and poorly water-soluble medicines. This review describes current status of pH-sensitive polymeric nanoparticles for oral drug delivery and introduces the mechanisms of drug release from them as well as possible reasons for absorption improvement, with emphasis on our contribution to this field. pH-sensitive polymeric nanoparticles are prepared mainly with polyanions, polycations, their mixtures or cross-linked polymers. The mechanisms of drug release are the result of carriers' dissolution, swelling or both of them at specific pH. The possible reasons for improvement of oral bioavailability include the following: improve drug stability, enhance mucoadhesion, prolong resident time in GI tract, ameliorate intestinal permeability and increase saturation solubility and dissolution rate for poorly water-soluble drugs. As for the advantages of pH-sensitive nanoparticles over conventional nanoparticles, we conclude that (1) most carriers used are enteric-coating materials and their safety has been approved. (2) The rapid dissolution or swelling of carriers at specific pH results in quick drug release and high drug concentration gradient, which is helpful for absorption. (3) At the specific pH carriers dissolve or swell, and the bioadhesion of carriers to mucosa becomes high because nanoparticles turn from solid to gel, which can facilitate drug absorption. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Efficient Generation and Selection of Combined Features for Improved Classification

    KAUST Repository

    Shono, Ahmad N.

    2014-05-01

    This study contributes a methodology and associated toolkit developed to allow users to experiment with the use of combined features in classification problems. Methods are provided for efficiently generating combined features from an original feature set, for efficiently selecting the most discriminating of these generated combined features, and for efficiently performing a preliminary comparison of the classification results when using the original features exclusively against the results when using the selected combined features. The potential benefit of considering combined features in classification problems is demonstrated by applying the developed methodology and toolkit to three sample data sets where the discovery of combined features containing new discriminating information led to improved classification results.

  13. Enhancing Breast Cancer Recurrence Algorithms Through Selective Use of Medical Record Data.

    Science.gov (United States)

    Kroenke, Candyce H; Chubak, Jessica; Johnson, Lisa; Castillo, Adrienne; Weltzien, Erin; Caan, Bette J

    2016-03-01

    The utility of data-based algorithms in research has been questioned because of errors in identification of cancer recurrences. We adapted previously published breast cancer recurrence algorithms, selectively using medical record (MR) data to improve classification. We evaluated second breast cancer event (SBCE) and recurrence-specific algorithms previously published by Chubak and colleagues in 1535 women from the Life After Cancer Epidemiology (LACE) and 225 women from the Women's Health Initiative cohorts and compared classification statistics to published values. We also sought to improve classification with minimal MR examination. We selected pairs of algorithms-one with high sensitivity/high positive predictive value (PPV) and another with high specificity/high PPV-using MR information to resolve discrepancies between algorithms, properly classifying events based on review; we called this "triangulation." Finally, in LACE, we compared associations between breast cancer survival risk factors and recurrence using MR data, single Chubak algorithms, and triangulation. The SBCE algorithms performed well in identifying SBCE and recurrences. Recurrence-specific algorithms performed more poorly than published except for the high-specificity/high-PPV algorithm, which performed well. The triangulation method (sensitivity = 81.3%, specificity = 99.7%, PPV = 98.1%, NPV = 96.5%) improved recurrence classification over two single algorithms (sensitivity = 57.1%, specificity = 95.5%, PPV = 71.3%, NPV = 91.9%; and sensitivity = 74.6%, specificity = 97.3%, PPV = 84.7%, NPV = 95.1%), with 10.6% MR review. Triangulation performed well in survival risk factor analyses vs analyses using MR-identified recurrences. Use of multiple recurrence algorithms in administrative data, in combination with selective examination of MR data, may improve recurrence data quality and reduce research costs. © The Author 2015. Published by Oxford University Press. All rights reserved. For

  14. Improvement of the sensitivity of CdTe detectors in the high energy regions

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Hiroshi; Ikegami, Kazunori; Takashima, Kazuo; Usami, Teruo [Mitsubishi Electric Corp., Tokyo (Japan); Yamamoto, Takayoshi

    1996-07-01

    In order to improve the efficiency of the full energy peak in the high energy regions, we had previously suggested a multi-layered structure of CdTe elements and have since confirmed the sensitivity improvement of the full energy peak. And furthermore, we have suggested a new type structure of multi-layered elements in this paper and we confirmed that the efficiency of the full energy peak became higher and that more proper energy spectra were obtained by our current experiment than by the detector with the conventional structure. This paper describes a simulation and experiment to improve the efficiency of the full energy peak and to obtain the more proper energy spectra of {sup 137}Cs (662keV) and {sup 60}Co (1.17 and 1.33MeV) using the new structure of CdTe detector. (J.P.N.)

  15. New C$_{6}$D$_{6}$ detectors: reduced neutron sensitivity and improved safety

    CERN Document Server

    Mastinu, Pierfrancesco; Berthoumieux, Eric; Cano-Ott, Daniel; Gramegna, F; Guerrero, Carlos; Massimi, Cristian; Milazzo, Paolo Maria; Mingrone, Federica; Praena, Javier; Prete, G; García, Aczel Regino

    2013-01-01

    During the 2011 data measurement campaign at n_TOF, the liquid scintillator detectors developed at FZK-Karlsruhe (hereafter named K6D6, [1]) and used with success along 10 years have shown ageing problems, mainly related to liquid leakage. The mould used to produce the carbon fiber structure, containing the liquid and the detection elements, was not available anymore and the technician involved in its construction was retired. Once decided to proceed to the production of new detectors (L6D6 in the following) two major items have been identified: - The detector setup must be able to work in the new class A experimental area (safety requirements advise to avoid the use of the old K6D6 in this area). - If possible, it is useful to reduce the neutron sensitivity, with the aim to have a liquid scintillator detector with very low neutron sensitivity (improving the already high performing K6D6). [1] R.Plag et al., NIM A496 (2003) 425

  16. Selection of antigenic markers on a GFP-Cκ fusion scaffold with high sensitivity by eukaryotic ribosome display

    International Nuclear Information System (INIS)

    Yang Yongmin; Barankiewicz, Teresa J.; He Mingyue; Taussig, Michael J.; Chen, Swey-Shen

    2007-01-01

    Ribosome display is a cell-free system permitting gene selection through the physical association of genetic material (mRNA) and its phenotypic (protein) product. While often used to select single-chain antibodies from large libraries by panning against immobilized antigens, we have adapted ribosome display for use in the 'reverse' format in order to select high affinity antigenic determinants against solid-phase antibody. To create an antigenic scaffold, DNA encoding green fluorescent protein (GFP) was fused to a light chain constant domain (Cκ) with stop codon deleted, and with 5' signals (T7 promoter, Kozak) enabling coupled transcription/translation in a eukaryotic cell-free system. Epitopes on either GFP (5') or Cκ (3') were selected by anti-GFP or anti-Cκ antibodies, respectively, coupled to magnetic beads. After selection, mRNA was amplified directly from protein-ribosome-mRNA (PRM) complexes by in situ PCR followed by internal amplification and reassembly PCR. As little as 10 fg of the 1 kb DNA construct, i.e. approximately 7500 molecules, could be recovered following a single round of interaction with solid-phase anti-GFP antibody. This platform is highly specific and sensitive for the antigen-antibody interaction and may permit selection and reshaping of high affinity antigenic variants of scaffold proteins

  17. The design and protocol of heat-sensitive moxibustion for knee osteoarthritis: a multicenter randomized controlled trial on the rules of selecting moxibustion location

    Directory of Open Access Journals (Sweden)

    Chi Zhenhai

    2010-06-01

    Full Text Available Abstract Background Knee osteoarthritis is a major cause of pain and functional limitation. Complementary and alternative medical approaches have been employed to relieve symptoms and to avoid the side effects of conventional medication. Moxibustion has been widely used to treat patients with knee osteoarthritis. Our past researches suggested heat-sensitive moxibustion might be superior to the conventional moxibustion. Our objective is to investigate the effectiveness of heat-sensitive moxibustion compared with conventional moxibustion or conventional drug treatment. Methods This study consists of a multi-centre (four centers in China, randomised, controlled trial with three parallel arms (A: heat-sensitive moxibustion; B: conventional moxibustion; C: conventional drug group. The moxibustion locations are different from A and B. Group A selects heat-sensitization acupoint from the region consisting of Yin Lingquan(SP9, Yang Lingquan(GB34, Liang Qiu(ST34, and Xue Hai (SP10. Meanwhile, fixed acupoints are used in group B, that is Xi Yan (EX-LE5 and He Ding (EX-LE2. The conventional drug group treats with intra-articular Sodium Hyaluronate injection. The outcome measures above will be assessed before the treatment, the 30 days of the last moxibustion session and 6 months after the last moxibustion session. Discussion This trial will utilize high quality trial methodologies in accordance with CONSORT guidelines. It will provide evidence for the effectiveness of moxibustion as a treatment for moderate and severe knee osteoarthritis. Moreover, the result will clarify the rules of heat-sensitive moxibustion location to improve the therapeutic effect with suspended moxibustion, and propose a new concept and a new theory of moxibustion to guide clinical practices. Trial Registration The trial is registered at Controlled Clinical Trials: ChiCTR-TRC-00000600.

  18. Fast, sensitive, and selective gas chromatography tandem mass spectrometry method for the target analysis of chemical secretions from femoral glands in lizards.

    Science.gov (United States)

    Sáiz, Jorge; García-Roa, Roberto; Martín, José; Gómara, Belén

    2017-09-08

    Chemical signaling is a widespread mode of communication among living organisms that is used to establish social organization, territoriality and/or for mate choice. In lizards, femoral and precloacal glands are important sources of chemical signals. These glands protrude chemical secretions used to mark territories and also, to provide valuable information from the bearer to other individuals. Ecologists have studied these chemical secretions for decades in order to increase the knowledge of chemical communication in lizards. Although several studies have focused on the chemical analysis of these secretions, there is a lack of faster, more sensitive and more selective analytical methodologies for their study. In this work a new GC coupled to tandem triple quadrupole MS (GC-QqQ (MS/MS)) methodology is developed and proposed for the target study of 12 relevant compounds often found in lizard secretions (i.e. 1-hexadecanol, palmitic acid, 1-octadecanol, oleic acid, stearic acid, 1-tetracosanol, squalene, cholesta-3,5-diene, α-tocopherol, cholesterol, ergosterol and campesterol). The method baseline-separated the analytes in less than 7min, with instrumental limits of detection ranging from 0.04 to 6.0ng/mL. It was possible to identify differences in the composition of the samples from the lizards analyzed, which depended on the species, the habitat occupied and the diet of the individuals. Moreover, α-tocopherol has been determined for the first time in a lizard species, which was thought to lack its expression in chemical secretions. Globally, the methodology has been proven to be a valuable alternative to other published methods with important improvements in terms of analysis time, sensitivity, and selectivity. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A hydrogel biosensor for high selective and sensitive detection of amyloid-beta oligomers.

    Science.gov (United States)

    Sun, Liping; Zhong, Yong; Gui, Jie; Wang, Xianwu; Zhuang, Xiaorong; Weng, Jian

    2018-01-01

    Alzheimer's disease (AD) is a neurodegenerative disorder characterized by progressive cognitive and memory impairment. It is the most common neurological disease that causes dementia. Soluble amyloid-beta oligomers (AβO) in blood or cerebrospinal fluid (CSF) are the pathogenic biomarker correlated with AD. A simple electrochemical biosensor using graphene oxide/gold nanoparticles (GNPs) hydrogel electrode was developed in this study. Thiolated cellular prion protein (PrP C ) peptide probe was immobilized on GNPs of the hydrogel electrode to construct an AβO biosensor. Electrochemical impedance spectroscopy was utilized for AβO analysis. The specific binding between AβO and PrP C probes on the hydrogel electrode resulted in an increase in the electron-transfer resistance. The biosensor showed high specificity and sensitivity for AβO detection. It could selectively differentiate AβO from amyloid-beta (Aβ) monomers or fibrils. Meanwhile, it was highly sensitive to detect as low as 0.1 pM AβO in artificial CSF or blood plasma. The linear range for AβO detection is from 0.1 pM to 10 nM. This biosensor could be used as a cost-effective tool for early diagnosis of AD due to its high electrochemical performance and bionic structure.

  20. Selecting Health Care Improvement Projects: A Methodology Integrating Cause-and-Effect Diagram and Analytical Hierarchy Process.

    Science.gov (United States)

    Testik, Özlem Müge; Shaygan, Amir; Dasdemir, Erdi; Soydan, Guray

    It is often vital to identify, prioritize, and select quality improvement projects in a hospital. Yet, a methodology, which utilizes experts' opinions with different points of view, is needed for better decision making. The proposed methodology utilizes the cause-and-effect diagram to identify improvement projects and construct a project hierarchy for a problem. The right improvement projects are then prioritized and selected using a weighting scheme of analytical hierarchy process by aggregating experts' opinions. An approach for collecting data from experts and a graphical display for summarizing the obtained information are also provided. The methodology is implemented for improving a hospital appointment system. The top-ranked 2 major project categories for improvements were identified to be system- and accessibility-related causes (45%) and capacity-related causes (28%), respectively. For each of the major project category, subprojects were then ranked for selecting the improvement needs. The methodology is useful in cases where an aggregate decision based on experts' opinions is expected. Some suggestions for practical implementations are provided.

  1. Detecting determinism with improved sensitivity in time series: rank-based nonlinear predictability score.

    Science.gov (United States)

    Naro, Daniel; Rummel, Christian; Schindler, Kaspar; Andrzejak, Ralph G

    2014-09-01

    The rank-based nonlinear predictability score was recently introduced as a test for determinism in point processes. We here adapt this measure to time series sampled from time-continuous flows. We use noisy Lorenz signals to compare this approach against a classical amplitude-based nonlinear prediction error. Both measures show an almost identical robustness against Gaussian white noise. In contrast, when the amplitude distribution of the noise has a narrower central peak and heavier tails than the normal distribution, the rank-based nonlinear predictability score outperforms the amplitude-based nonlinear prediction error. For this type of noise, the nonlinear predictability score has a higher sensitivity for deterministic structure in noisy signals. It also yields a higher statistical power in a surrogate test of the null hypothesis of linear stochastic correlated signals. We show the high relevance of this improved performance in an application to electroencephalographic (EEG) recordings from epilepsy patients. Here the nonlinear predictability score again appears of higher sensitivity to nonrandomness. Importantly, it yields an improved contrast between signals recorded from brain areas where the first ictal EEG signal changes were detected (focal EEG signals) versus signals recorded from brain areas that were not involved at seizure onset (nonfocal EEG signals).

  2. A highly selective biosensor with nanomolar sensitivity based on cytokinin dehydrogenase.

    Directory of Open Access Journals (Sweden)

    Faming Tian

    Full Text Available We have developed a N6-dimethylallyladenine (cytokinin dehydrogenase-based microbiosensor for real-time determination of the family of hormones known as cytokinins. Cytokinin dehydrogenase from Zea mays (ZmCKX1 was immobilised concurrently with electrodeposition of a silica gel film on the surface of a Pt microelectrode, which was further functionalized by free electron mediator 2,6-dichlorophenolindophenol (DCPIP in supporting electrolyte to give a bioactive film capable of selective oxidative cleavage of the N6- side chain of cytokinins. The rapid electron shuffling between freely diffusible DCPIP and the FAD redox group in ZmCKX1 endowed the microbiosensor with a fast response time of less than 10 s. The immobilised ZmCKX1 retained a high affinity for its preferred substrate N6-(Δ2-isopentenyl adenine (iP, and gave the miniaturized biosensor a large linear dynamic range from 10 nM to 10 µM, a detection limit of 3.9 nM and a high sensitivity to iP of 603.3 µAmM-1cm-2 (n = 4, R2 = 0.9999. Excellent selectivity was displayed for several other aliphatic cytokinins and their ribosides, including N6-(Δ2-isopentenyl adenine, N6-(Δ2-isopentenyl adenosine, cis-zeatin, trans-zeatin and trans-zeatin riboside. Aromatic cytokinins and metabolites such as cytokinin glucosides were generally poor substrates. The microbiosensors exhibited excellent stability in terms of pH and long-term storage and have been used successfully to determine low nanomolar cytokinin concentrations in tomato xylem sap exudates.

  3. An effective tumor-targeting strategy utilizing hypoxia-sensitive siRNA delivery system for improved anti-tumor outcome.

    Science.gov (United States)

    Kang, Lin; Fan, Bo; Sun, Ping; Huang, Wei; Jin, Mingji; Wang, Qiming; Gao, Zhonggao

    2016-10-15

    Hypoxia is a feature of most solid tumors, targeting hypoxia is considered as the best validated yet not extensively exploited strategy in cancer therapy. Here, we reported a novel tumor-targeting strategy using a hypoxia-sensitive siRNA delivery system. In the study, 2-nitroimidazole (NI), a hydrophobic component that can be converted to hydrophilic 2-aminoimidazole (AI) through bioreduction under hypoxic conditions, was conjugated to the alkylated polyethyleneimine (bPEI1.8k-C6) to form amphiphilic bPEI1.8k-C6-NI polycations. bPEI1.8k-C6-NI could self-assemble into micelle-like aggregations in aqueous, which contributed to the improved stability of the bPEI1.8k-C6-NI/siRNA polyplexes, resulted in increased cellular uptake. After being transported into the hypoxic tumor cells, the selective nitro-to-amino reduction would cause structural change and elicit a relatively loose structure to facilitate the siRNA dissociation in the cytoplasm, for enhanced gene silencing efficiency ultimately. Therefore, the conflict between the extracellular stability and the intracellular siRNA release ability of the polyplexes was solved by introducing the hypoxia-responsive unit. Consequently, the survivin-targeted siRNA loaded polyplexes shown remarkable anti-tumor effect not only in hypoxic cells, but also in tumor spheroids and tumor-bearing mice, indicating that the hypoxia-sensitive siRNA delivery system had great potential for tumor-targeted therapy. Hypoxia is one of the most remarkable features of most solid tumors, and targeting hypoxia is considered as the best validated strategy in cancer therapy. However, in the past decades, there were few reports about using this strategy in the drug delivery system, especially in siRNA delivery system. Therefore, we constructed a hypoxia-sensitive siRNA delivery system utilizing a hypoxia-responsive unit, 2-nitroimidazole, by which the unavoidable conflict between improved extracellular stability and promoted intracellular si

  4. Morning Versus Evening Bright Light Treatment at Home to Improve Function and Pain Sensitivity for Women with Fibromyalgia: A Pilot Study.

    Science.gov (United States)

    Burgess, Helen J; Park, Margaret; Ong, Jason C; Shakoor, Najia; Williams, David A; Burns, John

    2017-01-01

    To test the feasibility, acceptability, and effects of a home-based morning versus evening bright light treatment on function and pain sensitivity in women with fibromyalgia. A single blind randomized study with two treatment arms: 6 days of a 1 hour morning light treatment or 6 days of a 1 hour evening light treatment. Function, pain sensitivity, and circadian timing were assessed before and after treatment. Participants slept at home, except for two nights in Sleep Center. Ten women meeting the American College of Rheumatology's diagnostic criteria for fibromyalgia, including normal blood test results. Self-reported function was assessed with the Fibromyalgia Impact Questionnaire (FIQ). Pain sensitivity was assessed using a heat stimulus that gave measures of threshold and tolerance. Circadian timing was assessed with the dim light melatonin onset. Both morning and evening light treatments led to improvements in function and pain sensitivity. However, only the morning light treatment led to a clinically meaningful improvement in function (>14% reduction from baseline FIQ) and morning light significantly increased pain threshold more than evening light ( P  treatment appears to be a feasible and acceptable adjunctive treatment to women with fibromyalgia. Those who undergo morning light treatment may show improvements in function and pain sensitivity. Advances in circadian timing may be one mechanism by which morning light improves pain sensitivity. Findings can inform the design of a randomized controlled trial. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  5. Rac1 selective activation improves retina ganglion cell survival and regeneration.

    Directory of Open Access Journals (Sweden)

    Erika Lorenzetto

    Full Text Available In adult mammals, after optic nerve injury, retinal ganglion cells (RGCs do not regenerate their axons and most of them die by apoptosis within a few days. Recently, several strategies that activate neuronal intracellular pathways were proposed to prevent such degenerative processes. The rho-related small GTPase Rac1 is part of a complex, still not fully understood, intracellular signaling network, mediating in neurons many effects, including axon growth and cell survival. However, its role in neuronal survival and regeneration in vivo has not yet been properly investigated. To address this point we intravitreally injected selective cell-penetrating Rac1 mutants after optic nerve crush and studied the effect on RGC survival and axonal regeneration. We injected two well-characterized L61 constitutively active Tat-Rac1 fusion protein mutants, in which a second F37A or Y40C mutation confers selectivity in downstream signaling pathways. Results showed that, 15 days after crush, both mutants were able to improve survival and to prevent dendrite degeneration, while the one harboring the F37A mutation also improved axonal regeneration. The treatment with F37A mutant for one month did not improve the axonal elongation respect to 15 days. Furthermore, we found an increase of Pak1 T212 phosphorylation and ERK1/2 expression in RGCs after F37A treatment, whereas ERK1/2 was more activated in glial cells after Y40C administration. Our data suggest that the selective activation of distinct Rac1-dependent pathways could represent a therapeutic strategy to counteract neuronal degenerative processes in the retina.

  6. Improved targeted immunization strategies based on two rounds of selection

    Science.gov (United States)

    Xia, Ling-Ling; Song, Yu-Rong; Li, Chan-Chan; Jiang, Guo-Ping

    2018-04-01

    In the case of high degree targeted immunization where the number of vaccine is limited, when more than one node associated with the same degree meets the requirement of high degree centrality, how can we choose a certain number of nodes from those nodes, so that the number of immunized nodes will not exceed the limit? In this paper, we introduce a new idea derived from the selection process of second-round exam to solve this problem and then propose three improved targeted immunization strategies. In these proposed strategies, the immunized nodes are selected through two rounds of selection, where we increase the quotas of first-round selection according the evaluation criterion of degree centrality and then consider another characteristic parameter of node, such as node's clustering coefficient, betweenness and closeness, to help choose targeted nodes in the second-round selection. To validate the effectiveness of the proposed strategies, we compare them with the degree immunizations including the high degree targeted and the high degree adaptive immunizations using two metrics: the size of the largest connected component of immunized network and the number of infected nodes. Simulation results demonstrate that the proposed strategies based on two rounds of sorting are effective for heterogeneous networks and their immunization effects are better than that of the degree immunizations.

  7. Sensitive and selective culture medium for detection of environmental Clostridium difficile isolates without requirement for anaerobic culture conditions.

    Science.gov (United States)

    Cadnum, Jennifer L; Hurless, Kelly N; Deshpande, Abhishek; Nerandzic, Michelle M; Kundrapu, Sirisha; Donskey, Curtis J

    2014-09-01

    Effective and easy-to-use methods for detecting Clostridium difficile spore contamination would be useful for identifying environmental reservoirs and monitoring the effectiveness of room disinfection. Culture-based detection methods are sensitive for detecting C. difficile, but their utility is limited due to the requirement of anaerobic culture conditions and microbiological expertise. We developed a low-cost selective broth medium containing thioglycolic acid and l-cystine, termed C. difficile brucella broth with thioglycolic acid and l-cystine (CDBB-TC), for the detection of C. difficile from environmental specimens under aerobic culture conditions. The sensitivity and specificity of CDBB-TC (under aerobic culture conditions) were compared to those of CDBB (under anaerobic culture conditions) for the recovery of C. difficile from swabs collected from hospital room surfaces. CDBB-TC was significantly more sensitive than CDBB for recovering environmental C. difficile (36/41 [88%] versus 21/41 [51%], respectively; P = 0.006). C. difficile latex agglutination, an enzyme immunoassay for toxins A and B or glutamate dehydrogenase, and a PCR for toxin B genes were all effective as confirmatory tests. For 477 total environmental cultures, the specificity of CDBB-TC versus that of CDBB based upon false-positive yellow-color development of the medium without recovery of C. difficile was 100% (0 false-positive results) versus 96% (18 false-positive results), respectively. False-positive cultures for CDBB were attributable to the growth of anaerobic non-C. difficile organisms that did not grow in CDBB-TC. Our results suggest that CDBB-TC provides a sensitive and selective medium for the recovery of C. difficile organisms from environmental samples, without the need for anaerobic culture conditions. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  8. Double Solvent Sensing Method for Improving Sensitivity and Accuracy of Hg(II) Detection Based on Different Signal Transduction of a Tetrazine-Functionalized Pillared Metal-Organic Framework.

    Science.gov (United States)

    Razavi, Sayed Ali Akbar; Masoomi, Mohammad Yaser; Morsali, Ali

    2017-08-21

    To design a robust, π-conjugated, low-cost, and easy to synthesize metal-organic framework (MOF) for cation sensing by the photoluminescence (PL) method, 4,4'-oxybis(benzoic acid) (H 2 OBA) has been used in combination with 3,6-di(pyridin-4-yl)-1,2,4,5-tetrazine (DPT) as a tetrazine-functionalized spacer to construct [Zn(OBA)(DPT) 0.5 ]·DMF (TMU-34(-2H)). The tetrazine motif is a π-conjugated, water-soluble/stable fluorophore with relatively weak σ-donating Lewis basic sites. These characteristics of tetrazine make TMU-34(-2H) a good candidate for cation sensing. Because of hydrogen bonding between tetrazine moieties and water molecules, TMU-34(-2H) shows different PL emissions in water and acetonitrile. Cation sensing in these two solvents revealed that TMU-34(-2H) can selectively detect Hg 2+ in water (by 243% enhancement) and in acetonitrile (by 90% quenching). The contribution of electron-donating/accepting characteristics along with solvation effects on secondary interactions of the tetrazine motifs inside the TMU-34(-2H) framework results in different signal transductions. Improved sensitivity and accuracy of detection were obtained using the double solvent sensing method (DSSM), in which different signal transductions of TMU-34(-2H) in water and acetonitrile were combined simultaneously to construct a double solvent sensing curve and formulate a sensitivity factor. Calculation of sensitivity factors for all of the tested cations demonstrated that it is possible to detect Hg 2+ by DSSM with ultrahigh sensitivity. Such a tremendous distinction in the Hg 2+ sensitivity factor is visualizable in the double solvent sensing curve. Thus, by application of DSSM instead of one-dimensional sensing, the interfering effects of other cations are completely eliminated and the sensitivity toward Hg(II) is highly improved. Strong interactions between Hg 2+ and the nitrogen atoms of the tetrazine groups along with easy accessibility of Hg 2+ to the tetrazine groups lead

  9. Cinnamon extract improves insulin sensitivity in the brain and lowers liver fat in mouse models of obesity.

    Science.gov (United States)

    Sartorius, Tina; Peter, Andreas; Schulz, Nadja; Drescher, Andrea; Bergheim, Ina; Machann, Jürgen; Schick, Fritz; Siegel-Axel, Dorothea; Schürmann, Annette; Weigert, Cora; Häring, Hans-Ulrich; Hennige, Anita M

    2014-01-01

    Treatment of diabetic subjects with cinnamon demonstrated an improvement in blood glucose concentrations and insulin sensitivity but the underlying mechanisms remained unclear. This work intends to elucidate the impact of cinnamon effects on the brain by using isolated astrocytes, and an obese and diabetic mouse model. Cinnamon components (eugenol, cinnamaldehyde) were added to astrocytes and liver cells to measure insulin signaling and glycogen synthesis. Ob/ob mice were supplemented with extract from cinnamomum zeylanicum for 6 weeks and cortical brain activity, locomotion and energy expenditure were evaluated. Insulin action was determined in brain and liver tissues. Treatment of primary astrocytes with eugenol promoted glycogen synthesis, whereas the effect of cinnamaldehyde was attenuated. In terms of brain function in vivo, cinnamon extract improved insulin sensitivity and brain activity in ob/ob mice, and the insulin-stimulated locomotor activity was improved. In addition, fasting blood glucose levels and glucose tolerance were greatly improved in ob/ob mice due to cinnamon extracts, while insulin secretion was unaltered. This corresponded with lower triglyceride and increased liver glycogen content and improved insulin action in liver tissues. In vitro, Fao cells exposed to cinnamon exhibited no change in insulin action. Together, cinnamon extract improved insulin action in the brain as well as brain activity and locomotion. This specific effect may represent an important central feature of cinnamon in improving insulin action in the brain, and mediates metabolic alterations in the periphery to decrease liver fat and improve glucose homeostasis.

  10. Highly sensitive and selective SO2 MOF sensor: the integration of MFM-300 MOF as a sensitive layer on a capacitive interdigitated electrode

    KAUST Repository

    Chernikova, Valeriya; Yassine, Omar; Shekhah, Osama; Eddaoudi, Mohamed; Salama, Khaled N.

    2018-01-01

    We report on the fabrication of an advanced chemical capacitive sensor for the detection of sulfur dioxide (SO2) at room temperature. The sensing layer based on an indium metal–organic framework (MOF), namely MFM-300, is coated solvothermally on a functionalized capacitive interdigitated electrode. The fabricated sensor exhibits significant detection sensitivity to SO2 at concentrations down to 75 ppb, with the lower detection limit estimated to be around 5 ppb. The MFM-300 MOF sensor demonstrates highly desirable detection selectivity towards SO2 vs. CH4, CO2, NO2 and H2, as well as an outstanding SO2 sensing stability.

  11. Highly sensitive and selective SO2 MOF sensor: the integration of MFM-300 MOF as a sensitive layer on a capacitive interdigitated electrode

    KAUST Repository

    Chernikova, Valeriya

    2018-03-05

    We report on the fabrication of an advanced chemical capacitive sensor for the detection of sulfur dioxide (SO2) at room temperature. The sensing layer based on an indium metal–organic framework (MOF), namely MFM-300, is coated solvothermally on a functionalized capacitive interdigitated electrode. The fabricated sensor exhibits significant detection sensitivity to SO2 at concentrations down to 75 ppb, with the lower detection limit estimated to be around 5 ppb. The MFM-300 MOF sensor demonstrates highly desirable detection selectivity towards SO2 vs. CH4, CO2, NO2 and H2, as well as an outstanding SO2 sensing stability.

  12. An improved electrochemiluminescence polymerase chain reaction method for highly sensitive detection of plant viruses

    International Nuclear Information System (INIS)

    Tang Yabing; Xing Da; Zhu Debin; Liu Jinfeng

    2007-01-01

    Recently, we have reported an electrochemiluminescence polymerase chain reaction (ECL-PCR) method for detection of genetically modified organisms. The ECL-PCR method was further improved in the current study by introducing a multi-purpose nucleic acid sequence that was specific to the tris(bipyridine) ruthenium (TBR) labeled probe, into the 5' terminal of the primers. The method was applied to detect plant viruses. Conserved sequence of the plant viruses was amplified by PCR. The product was hybridized with a biotin labeled probe and a TBR labeled probe. The hybridization product was separated by streptavidin-coated magnetic beads, and detected by measuring the ECL signals of the TBR labeled. Under the optimized conditions, the experiment results show that the detection limit is 50 fmol of PCR products, and the signal-to-noise ratio is in excess of 14.6. The method was used to detect banana streak virus, banana bunchy top virus, and papaya leaf curl virus. The experiment results show that this method could reliably identity viruses infected plant samples. The improved ECL-PCR approach has higher sensitivity and lower cost than previous approach. It can effectively detect the plant viruses with simplicity, stability, and high sensitivity

  13. A highly sensitive, single selective, fluorescent sensor for Al3+ detection and its application in living cell imaging

    International Nuclear Information System (INIS)

    Ye, Xing-Pei; Sun, Shao-bo; Li, Ying-dong; Zhi, Li-hua; Wu, Wei-na; Wang, Yuan

    2014-01-01

    A new o-aminophenol-based fluorogenic chemosensor methyl 3,5-bis((E)-(2-hydroxyphenylimino)methyl)-4-hydroxybenzoate 1 have been synthesized by Schiff base condensation of methyl 3,5-diformyl-4-hydroxybenzoate with o-aminophenol, which exhibits high selectivity and sensitivity toward Al 3+ . Fluorescence titration studies of receptors 1 with different metal cations in CH 3 OH medium showed highly selective and sensitive towards Al 3+ ions even in the presence of other commonly coexisting metal ions. The detection limit of Al 3+ ions is at the parts per billion level. Interestingly, the Al(III) complex of 1 offered a large Stokes shift (>120 nm), which can miximize the selfquenching effect. In addition, possible utilization of this receptor as bio-imaging fluorescent probe to detect Al 3+ in human cervical HeLa cancer cell lines was also investigated by confocal fluorescence microscopy. - Highlights: • A new Schiff base chemosensor is reported. • The sensor for Al 3+ offers large Stokes shift. • The detection limit of Al 3+ in CH 3 OH solution is at the parts per billion level. • The utilization of sensor for the monitoring of Al 3+ levels in living cells was examined

  14. An improved strategy for skin lesion detection and classification using uniform segmentation and feature selection based approach.

    Science.gov (United States)

    Nasir, Muhammad; Attique Khan, Muhammad; Sharif, Muhammad; Lali, Ikram Ullah; Saba, Tanzila; Iqbal, Tassawar

    2018-02-21

    Melanoma is the deadliest type of skin cancer with highest mortality rate. However, the annihilation in early stage implies a high survival rate therefore, it demands early diagnosis. The accustomed diagnosis methods are costly and cumbersome due to the involvement of experienced experts as well as the requirements for highly equipped environment. The recent advancements in computerized solutions for these diagnoses are highly promising with improved accuracy and efficiency. In this article, we proposed a method for the classification of melanoma and benign skin lesions. Our approach integrates preprocessing, lesion segmentation, features extraction, features selection, and classification. Preprocessing is executed in the context of hair removal by DullRazor, whereas lesion texture and color information are utilized to enhance the lesion contrast. In lesion segmentation, a hybrid technique has been implemented and results are fused using additive law of probability. Serial based method is applied subsequently that extracts and fuses the traits such as color, texture, and HOG (shape). The fused features are selected afterwards by implementing a novel Boltzman Entropy method. Finally, the selected features are classified by Support Vector Machine. The proposed method is evaluated on publically available data set PH2. Our approach has provided promising results of sensitivity 97.7%, specificity 96.7%, accuracy 97.5%, and F-score 97.5%, which are significantly better than the results of existing methods available on the same data set. The proposed method detects and classifies melanoma significantly good as compared to existing methods. © 2018 Wiley Periodicals, Inc.

  15. Improving Medical Decision Making and Health Promotion through Culture-Sensitive Health Communication : an Agenda for Science and Practice

    OpenAIRE

    Betsch, Cornelia; Böhm, Robert; Airhihenbuwa, Collins O.; Butler, Robb; Chapman, Gretchen B.; Haase, Niels; Herrmann, Benedikt; Igarashi, Tasuku; Kitayama, Shinobu; Korn, Lars; Nurm, Ülla-Karin; Rohrmann, Bernd; Rothman, Alexander J.; Shavitt, Sharon; Updegraff, John A.

    2016-01-01

    This review introduces the concept of culture-sensitive health communication. The basic premise is that congruency between the recipient's cultural characteristics and the respective message will increase the communication's effectiveness. Culture-sensitive health communication is therefore defined as the deliberate and evidence-informed adaptation of health communication to the recipients' cultural background in order to increase knowledge and improve preparation for medical decision making ...

  16. First evidence that drugs of abuse produce behavioral sensitization and cross-sensitization in planarians

    Science.gov (United States)

    Rawls, Scott M.; Patil, Tavni; Yuvasheva, Ekaternia; Raffa, Robert B.

    2010-01-01

    Behavioral sensitization in mammals, including humans, is sensitive to factors such as administration route, testing environment, and pharmacokinetic confounds, unrelated to the drugs themselves, that are difficult to eliminate. Simpler animals less susceptible to these confounding influences may be advantageous substitutes for studying sensitization. We tested this hypothesis by determining if planarians display sensitization and cross-sensitization to cocaine and glutamate. Planarian hyperactivity was quantified as the number of C-like hyperkinesias during a 1-min drug exposure. Planarians exposed initially to cocaine (or glutamate) on day 1 were challenged with cocaine (or glutamate) after 2 or 6 days of abstinence. Acute cocaine or glutamate produced concentration-related hyperactivity. Cocaine or glutamate challenge after 2 and 6 days of abstinence enhanced the hyperactivity, indicating the substances produced planarian behavioral sensitization (pBS). Cross-sensitization experiments showed that cocaine produced greater hyperactivity in planarians previously exposed to glutamate than in glutamate-naïve planarians, and vice versa. Behavioral responses were pharmacologically selective because neither scopolamine nor caffeine produced pBS despite causing hyperactivity after initial administration, and acute GABA did not cause hyperactivity. Demonstration of pharmacologically-selective behavioral sensitization in planarians suggests these flatworms represent a sensitive in vivo model to study cocaine behavioral sensitization and to screen potential abuse-deterrent therapeutics. PMID:20512030

  17. Sensitive and selective electrochemical detection of chromium(VI) based on gold nanoparticle-decorated titania nanotube arrays.

    Science.gov (United States)

    Jin, Wei; Wu, Guosheng; Chen, Aicheng

    2014-01-07

    Owing to the severe toxicity and mobility of Cr(VI) in biological and environmental systems, it is of great importance to develop convenient and reliable methods for its detection. Here we report on a facile and effective electrochemical technique for monitoring Cr(VI) concentrations based on the utilization of Au nanoparticle-decorated titania nanotubes (TiO2NTs) grown on a titanium substrate. It was found that the electrochemical reduction of Cr(VI) at the Ti/TiO2NT/Au electrode exhibited an almost 23 fold improvement in activity as compared to a polycrystalline gold electrode, due to its nanoparticle/nanotubular heterojunction infrastructure. As a result, the Ti/TiO2NT/Au electrode demonstrated a wide linear concentration range from 0.10 μM to 105 μM, a low detection limit of 0.03 μM, and a high sensitivity of 6.91 μA μM(-1) Cr(VI) via amperometry, satisfying the detection requirements of the World Health Organization (WHO). Moreover, the Ti/TiO2NT/Au electrode exhibited good resistance against interference from coexisting Cr(III) and other metal ions, and excellent recovery for Cr(VI) detection in both tap and lake water samples. These attributes suggest that this hybrid sensor has strong potential in applications for the selective detection of Cr(VI).

  18. l-Tryptophan-capped carbon quantum dots for the sensitive and selective fluorescence detection of mercury ion in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Xuejuan; Li, Shifeng; Zhuang, Lulu; Tang, Jiaoning, E-mail: tjn@szu.edu.cn [Shenzhen University, Shenzhen Key Laboratory of Special Functional Materials, College of Materials Science and Engineering (China)

    2016-07-15

    l-Tryptophan-capped carbon quantum dots (l-CQDs) were facilely synthesized through “green” methodology, and the obtained material was utilized as a sensitive and selective fluorescence sensor for mercury ion (Hg{sup 2+}) in pure aqueous solutions. Carboxyl-functionalized CQDs were first green synthesized by a one-step hydrothermal route, and l-tryptophan was then attached to CQDs via direct surface condensation reaction in aqueous solution at room temperature. The as-synthesized l-CQDs had an average size of ca. 5 nm with a good dispersity in water, and exhibited a favorable selectivity for Hg{sup 2+} ions over a range of other common metal cations in aqueous solution (10 mM PBS buffer, pH 6.0). Upon the addition of Hg{sup 2+}, a complete fluorescence quenching (ON–OFF switching) of l-CQDs was evident from the fluorescence titration experiment, and the fluorescence detection limit of Hg{sup 2+} was calculated to be 11 nM, which indicated that the obtained environmentally friendly l-CQDs had sensitive detection capacity for Hg{sup 2+} in aqueous solution.

  19. New scoring methodology improves the sensitivity of the Alzheimer's Disease Assessment Scale-Cognitive subscale (ADAS-Cog) in clinical trials.

    Science.gov (United States)

    Verma, Nishant; Beretvas, S Natasha; Pascual, Belen; Masdeu, Joseph C; Markey, Mia K

    2015-11-12

    As currently used, the Alzheimer's Disease Assessment Scale-Cognitive subscale (ADAS-Cog) has low sensitivity for measuring Alzheimer's disease progression in clinical trials. A major reason behind the low sensitivity is its sub-optimal scoring methodology, which can be improved to obtain better sensitivity. Using item response theory, we developed a new scoring methodology (ADAS-CogIRT) for the ADAS-Cog, which addresses several major limitations of the current scoring methodology. The sensitivity of the ADAS-CogIRT methodology was evaluated using clinical trial simulations as well as a negative clinical trial, which had shown an evidence of a treatment effect. The ADAS-Cog was found to measure impairment in three cognitive domains of memory, language, and praxis. The ADAS-CogIRT methodology required significantly fewer patients and shorter trial durations as compared to the current scoring methodology when both were evaluated in simulated clinical trials. When validated on data from a real clinical trial, the ADAS-CogIRT methodology had higher sensitivity than the current scoring methodology in detecting the treatment effect. The proposed scoring methodology significantly improves the sensitivity of the ADAS-Cog in measuring progression of cognitive impairment in clinical trials focused in the mild-to-moderate Alzheimer's disease stage. This provides a boost to the efficiency of clinical trials requiring fewer patients and shorter durations for investigating disease-modifying treatments.

  20. A low-fat Diet improves insulin sensitivity in patients with type 1 diabetes

    DEFF Research Database (Denmark)

    Rosenfalck, AM; Almdal, Thomas Peter; Viggers, Lone

    2006-01-01

    diet (P = 0.039). The daily protein and carbohydrate intake increased (+4.4% of total energy intake, P = 0.0049 and +2.5%, P = 0.34, respectively), while alcohol intake decreased (-3.2% of total energy intake, P = 0.02). There was a significant improvement in insulin sensitivity on the isocaloric, low-fat......AIMS: To compare the effects on insulin sensitivity, body composition and glycaemic control of the recommended standard weight-maintaining diabetes diet and an isocaloric low-fat diabetes diet during two, 3-month periods in patients with Type 1 diabetes. METHODS: Thirteen Type 1 patients were...... by the insulin clamp technique at baseline and after each of the diet intervention periods. RESULTS: On an isocaloric low-fat diet, Type 1 diabetic patients significantly reduced the proportion of fat in the total daily energy intake by 12.1% (or -3.6% of total energy) as compared with a conventional diabetes...

  1. Reduce the Sensitivity of CL-20 by Improving Thermal Conductivity Through Carbon Nanomaterials.

    Science.gov (United States)

    Wang, Shuang; An, Chongwei; Wang, Jingyu; Ye, Baoyun

    2018-03-27

    The graphene (rGO) and carbon nanotube (CNT) were adopted to enhance the thermal conductivity of CL-20-based composites as conductive fillers. The microstructure features were characterized using scanning electron microscopy (SEM) and X-ray diffraction (XRD), and tested the properties by differential scanning calorimeter (DSC), static electricity accumulation, special height, thermal conductivity, and detonation velocity. The results showed that the mixture of rGO and CNT had better effect in thermal conductivity than rGO or CNT alone under the same loading (1 wt%) and it formed a three-dimensional heat-conducting network structure to improve the heat property of the system. Besides, the linear fit proved that the thermal conductivity of the CL-20-based composites were negatively correlated with the impact sensitivity, which also explained that the impact sensitivity was significantly reduced after the thermal conductivity increased and the explosive still maintained better energy.

  2. Reduce the Sensitivity of CL-20 by Improving Thermal Conductivity Through Carbon Nanomaterials

    Science.gov (United States)

    Wang, Shuang; An, Chongwei; Wang, Jingyu; Ye, Baoyun

    2018-03-01

    The graphene (rGO) and carbon nanotube (CNT) were adopted to enhance the thermal conductivity of CL-20-based composites as conductive fillers. The microstructure features were characterized using scanning electron microscopy (SEM) and X-ray diffraction (XRD), and tested the properties by differential scanning calorimeter (DSC), static electricity accumulation, special height, thermal conductivity, and detonation velocity. The results showed that the mixture of rGO and CNT had better effect in thermal conductivity than rGO or CNT alone under the same loading (1 wt%) and it formed a three-dimensional heat-conducting network structure to improve the heat property of the system. Besides, the linear fit proved that the thermal conductivity of the CL-20-based composites were negatively correlated with the impact sensitivity, which also explained that the impact sensitivity was significantly reduced after the thermal conductivity increased and the explosive still maintained better energy.

  3. Surface science study of selective ethylene epoxidation catalyzed by the Ag(110) surface: Structural sensitivity

    International Nuclear Information System (INIS)

    Campbell, C.T.

    1984-01-01

    The selective oxidation of ethylene to ethylene epoxide (C 2 H 4 +1/2O 2 →C 2 H 4 O) over Ag is the simplest example of kinetically controlled, selective heterogeneous catalysis. We have studied the steady-state kinetics and selectivity of this reaction for the first time on a clean, well-characterized Ag(110) surface by using a special apparatus which allows rapid (approx.20 s) transfer between a high-pressure catalytic microreactor and an ultrahigh vacuum surface analysis (AES, XPS, LEED, TDS) chamber. The effects of temperature and reactant pressures upon the rate and selectivity are virtually identical on Ag(110) and supported, high surface area Ag catalysts. The absolute specific rate (per Ag surface atom) is, however, some 100-fold higher for Ag(110) than for high surface area catalysts. This is related to the well-known structural sensitivity of this reaction. It is postulated that a small percentage of (110) planes (or [110]-like sites) are responsible for most of the catalytic activity of high surface area catalysts. The high activity of the (110) plane is attributed to its high sticking probability for dissociative oxygen adsorption, since the rate of ethylene epoxidation is shown in a related work [Ref. 1: C. T. Campbell and M. T. Paffett, Surf. Sci. (in press)] to be proportional to the coverage of atomically adsorbed oxygen at constant temperature and ethylene pressure

  4. Developing optical traps for ultra-sensitive analysis

    International Nuclear Information System (INIS)

    Zhao, X.; Vieira, D.J.; Guckert, R.; Crane, S.

    1998-01-01

    The authors describe the coupling of a magneto-optical trap to a mass separator for the ultra-sensitive detection of selected radioactive species. As a proof of principle test, they have demonstrated the trapping of ∼ 6 million 82 Rb (t 1/2 = 75 s) atoms using an ion implantation and heated foil release method for introducing the sample into a trapping cell with minimal gas loading. Gamma-ray counting techniques were used to determine the efficiencies of each step in the process. By far the weakest step in the process is the efficiency of the optical trap itself (0.3%). Further improvements in the quality of the nonstick dryfilm coating on the inside of the trapping cell and the possible use of larger diameter laser beams are indicated. In the presence of a large background of scattered light, this initial work achieved a detection sensitivity of ∼ 4,000 trapped atoms. Improved detection schemes using a pulsed trap and gated photon detection method are outlined. Application of this technology to the areas of environmental monitoring and nuclear proliferation are foreseen

  5. Microarray study of temperature-dependent sensitivity and selectivity of metal/oxide sensing interfaces

    Science.gov (United States)

    Tiffany, Jason; Cavicchi, Richard E.; Semancik, Stephen

    2001-02-01

    Conductometric gas microsensors offer the benefits of ppm-level sensitivity, real-time data, simple interfacing to electronics hardware, and low power consumption. The type of device we have been exploring consists of a sensor film deposited on a "microhotplate"- a 100 micron platform with built-in heating (to activate reactions on the sensing surface) and thermometry. We have been using combinatorial studies of 36-element arrays to characterize the relationship between sensor film composition, operating temperature, and response, as measured by the device's sensitivity and selectivity. Gases that have been tested on these arrays include methanol, ethanol, dichloromethane, propane, methane, acetone, benzene, hydrogen, and carbon monoxide, and are of interest in the management of environmental waste sites. These experiments compare tin oxide films modified by catalyst overlayers, and ultrathin metal seed layers. The seed layers are used as part of a chemical vapor deposition process that uses each array element's microheater to activate the deposition of SnO2, and control its microstructure. Low coverage (20 Ê) catalytic metals (Pd, Cu, Cr, In, Au) are deposited on the oxides by masked evaporation or sputtering. This presentation demonstrates the value of an array-based approach for developing film processing methods, measuring performance characteristics, and establishing reproducibility. It also illustrates how temperature-dependent response data for varied metal/oxide compositions can be used to tailor a microsensor array for a given application.

  6. Highly sensitive and selective detection of Bis-phenol A based on hydroxyapatite decorated reduced graphene oxide nanocomposites

    International Nuclear Information System (INIS)

    Alam, Mohammad K.; Rahman, Mohammed M.; Elzwawy, Amir; Torati, Sri Ramulu; Islam, Mohammad S.; Todo, Mitsugu; Asiri, Abdullah M.; Kim, Dojin; Kim, CheolGi

    2017-01-01

    Highlights: •Simple chemical reduction method was used for preparation of reduced graphene oxide/hydroxyapatite (rGO/HAp) nanocomposites. •The rGO/HAp nanocomposites exhibited good biocompatibility with hMSCs. •Selective chemical sensor based on rGO/HAp nanocomposites was developed for detection of Bis-phenol A. •The fabricated rGO/HAp/Nafion/GCE sensor exhibited good detection limit of 60 pmol L −1 . -- Abstract: A facile and cost effective chemical reduction method is employed for the preparation of reduced graphene oxide/hydroxyapatite (rGO/HAp) nanocomposites. The transmission electron microscopy images revealed that the HAp flakes are well decorated on the surface of rGO. The morphological structure of the as-synthesized rGO/HAp nanocomposites was confirmed through X-ray diffraction, Fourier transform infrared spectroscopy and Raman spectroscopy, while the composition and thermal stability were analyzed by energy dispersive spectra and thermogravimetric analysis, respectively. Furthermore, the effect of rGO/HAp nanocomposites for the proliferation of Human Mesenchymal Stem Cell (hMSC) was performed to confirm the biocompatibility. A selective chemical sensor based on rGO/HAp modified glassy carbon electrode (GCE) for sensitive detection of Bis-phenol A (BPA) has been developed. Several important parameters controlling the performance of the BPA chemi-sensor were investigated and optimized at room conditions. The rGO/HAp/Nafion/GCE sensor offers a fast response and highly sensitive BPA detection. Under the optimal conditions, a linear range from 0.2 nmol L −1 to 2.0 mmol L −1 for the detection of BPA was observed with the detection limit of 60.0 pmol L −1 (signal-to-noise ratio, at an SNR of 3) and sensitivity of 18.98 × 10 4 μA.L/μmol.m 2 . Meanwhile, the fabricated chemi-sensor showed an excellent, specific and selective recognition to target BPA molecules among coexistence of other analytes in the buffer system. This novel effort initiated

  7. Improved CT-detection of acute bowel ischemia using frequency selective non-linear image blending.

    Science.gov (United States)

    Schneeweiss, Sven; Esser, Michael; Thaiss, Wolfgang; Boesmueller, Hans; Ditt, Hendrik; Nikolau, Konstantin; Horger, Marius

    2017-07-01

    Computed tomography (CT) as a fast and reliable diagnostic technique is the imaging modality of choice for acute bowel ischemia. However, diagnostic is often difficult mainly due to low attenuation differences between ischemic and perfused segments. To compare the diagnostic efficacy of a new post-processing tool based on frequency selective non-linear blending with that of conventional linear contrast-enhanced CT (CECT) image blending for the detection of bowel ischemia. Twenty-seven consecutive patients (19 women; mean age = 73.7 years, age range = 50-94 years) with acute bowel ischemia were scanned using multidetector CT (120 kV; 100-200 mAs). Pre-contrast and portal venous scans (65-70 s delay) were acquired. All patients underwent surgery for acute bowel ischemia and intraoperative diagnosis as well as histologic evaluation of explanted bowel segments was considered "gold standard." First, two radiologists read the conventional CECT images in which linear blending was adapted for optimal contrast, and second (three weeks later) the frequency selective non-linear blending (F-NLB) image. Attenuation values were compared, both in the involved and non-involved bowel segments creating ratios between unenhanced and CECT. The mean attenuation difference between ischemic and non-ischemic wall in the portal venous scan was 69.54 HU (reader 2 = 69.01 HU) higher for F-NLB compared with conventional CECT. Also, the attenuation ratio between contrast-enhanced and pre-contrast CT data for the non-ischemic walls showed significantly higher values for the F-NLB image (CECT: reader 1 = 2.11 (reader 2 = 3.36), F-NLB: reader 1 = 4.46 (reader 2 = 4.98)]. Sensitivity in detecting ischemic areas increased significantly for both readers using F-NLB (CECT: reader 1/2 = 53%/65% versus F-NLB: reader 1/2 = 62%/75%). Frequency selective non-linear blending improves detection of bowel ischemia compared with conventional CECT by increasing

  8. Selection of antigenic markers on a GFP-C{kappa} fusion scaffold with high sensitivity by eukaryotic ribosome display

    Energy Technology Data Exchange (ETDEWEB)

    Yongmin, Yang [Institute of Genetics, San Diego, CA 92121-2233 (United States); IgE Therapeutics, Inc., San Diego, CA 92121-2233 (United States); Barankiewicz, Teresa J [Institute of Genetics, San Diego, CA 92121-2233 (United States); IgE Therapeutics, Inc., San Diego, CA 92121-2233 (United States); Mingyue, He [Babraham Institute, Cambridge CB2 4AT (United Kingdom); Taussig, Michael J [Babraham Institute, Cambridge CB2 4AT (United Kingdom); Chen, Swey-Shen [Institute of Genetics, San Diego, CA 92121-2233 (United States) and IgE Therapeutics, Inc., San Diego, CA 92121-2233 (United States)

    2007-07-27

    Ribosome display is a cell-free system permitting gene selection through the physical association of genetic material (mRNA) and its phenotypic (protein) product. While often used to select single-chain antibodies from large libraries by panning against immobilized antigens, we have adapted ribosome display for use in the 'reverse' format in order to select high affinity antigenic determinants against solid-phase antibody. To create an antigenic scaffold, DNA encoding green fluorescent protein (GFP) was fused to a light chain constant domain (C{kappa}) with stop codon deleted, and with 5' signals (T7 promoter, Kozak) enabling coupled transcription/translation in a eukaryotic cell-free system. Epitopes on either GFP (5') or C{kappa} (3') were selected by anti-GFP or anti-C{kappa} antibodies, respectively, coupled to magnetic beads. After selection, mRNA was amplified directly from protein-ribosome-mRNA (PRM) complexes by in situ PCR followed by internal amplification and reassembly PCR. As little as 10 fg of the 1 kb DNA construct, i.e. approximately 7500 molecules, could be recovered following a single round of interaction with solid-phase anti-GFP antibody. This platform is highly specific and sensitive for the antigen-antibody interaction and may permit selection and reshaping of high affinity antigenic variants of scaffold proteins.

  9. Influence of Feature Selection Methods on Classification Sensitivity Based on the Example of A Study of Polish Voivodship Tourist Attractiveness

    Directory of Open Access Journals (Sweden)

    Bąk Iwona

    2014-07-01

    Full Text Available The purpose of this article is to determine the influence of various methods of selection of diagnostic features on the sensitivity of classification. Three options of feature selection are presented: a parametric feature selection method with a sum (option I, a median of the correlation coefficients matrix column elements (option II and the method of a reversed matrix (option III. Efficiency of the groupings was verified by the indicators of homogeneity, heterogeneity and the correctness of grouping. In the assessment of group efficiency the approach with the Weber median was used. The undertaken problem was illustrated with a research into the tourist attractiveness of voivodships in Poland in 2011.

  10. Influence of plasticizer on the selectivity of nitrate-sensitive CHEMFETs

    NARCIS (Netherlands)

    Stauthamer, W.P.R.V.; Stauthamer, W.P.R.V.; Engbersen, Johannes F.J.; Verboom, Willem; Reinhoudt, David

    1994-01-01

    By chemical modification of an ion-sensitive field-effect transistor, a sensor (CHEMFET) has been developed whose sensitivity for nitrate has been tested. A plasticized poly(vinyl chloride) (PVC) membrane, which contains lipophilic tetra-n-octyl-ammonium ions, is responsible for the nitrate

  11. Sensitive and Selective Ratiometric Fluorescence Probes for Detection of Intracellular Endogenous Monoamine Oxidase A.

    Science.gov (United States)

    Wu, Xiaofeng; Li, Lihong; Shi, Wen; Gong, Qiuyu; Li, Xiaohua; Ma, Huimin

    2016-01-19

    Monoamine oxidase A (MAO-A) is known to widely exist in most cell lines in the body, and its dysfunction (unusually high or low levels of MAO-A) is thought to be responsible for several psychiatric and neurological disorders. Thus, a sensitive and selective method for evaluating the relative MAO-A levels in different live cells is urgently needed to better understand the function of MAO-A, but to our knowledge such a method is still lacking. Herein, we rationally design two new ratiometric fluorescence probes (1 and 2) that can sensitively and selectively detect MAO-A. The probes are constructed by incorporating a recognition group of propylamine into the fluorescent skeleton of 1,8-naphthalimide, and the detection mechanism is based on amine oxidation and β-elimination to release the fluorophore (4-hydroxy-N-butyl-1,8-naphthalimide), which is verified by HPLC analysis. Reaction of the probes with MAO-A produces a remarkable fluorescence change from blue to green, and the ratio of fluorescence intensity at 550 and 454 nm is directly proportional to the concentration of MAO-A in the ranges of 0.5-1.5 and 0.5-2.5 μg/mL with detection limits of 1.1 and 10 ng/mL (k = 3) for probes 1 and 2, respectively. Surprisingly, these probes show strong fluorescence responses to MAO-A but almost none to MAO-B (one of two isoforms of MAO), indicating superior ability to distinguish MAO-A from MAO-B. The high specificity of the probes for MAO-A over MAO-B is further supported by different inhibitor experiments. Moreover, probe 1 displays higher sensitivity than probe 2 and is thus investigated to image the relative MAO-A levels in different live cells, such as HeLa and NIH-3T3 cells. It is found that the concentration of endogenous MAO-A in HeLa cells is approximately 1.8 times higher than that in NIH-3T3 cells, which is validated by the result from an ELISA kit. Additionally, the proposed probes may find more uses in the specific detection of MAO-A between the two isoforms of MAO

  12. Radioimmunoassay of the myelin basic protein in biological fluids, conditions improving sensitivity and specificity

    International Nuclear Information System (INIS)

    Delassalle, A.; Jacque, C.; Raoul, M.; Legrand, J.C.; Cesselin, F.; Drouet, J.

    1980-01-01

    The radioimmunoassay (RIA) for myelin basic protein (MBP) in biological fluids was reassessed in order to improve its sensitivity and eliminate some interferences. By using the pre-incubation technique and the charcoal-dextram-horse serum mixture for the separation step, the detection limit could be lowered to 200 pg/ml for cerebrospinal fluids (CSF), amniotic fluids (AF) and nervous tissue extracts and 600 pg/ml for sera. The RIA could be used directly on CSF, AF and nervous tissue extracts. Sera, however, had to be heated in citrate buffer at 100 0 C in order to discard interfering material. The present method is 10 to 20 times more sensitive than others previously published. Moreover, it can be applied to amniotic fluid. The biological fluids had to be promptly frozen to avoid degradation of MBP

  13. Improving CT detection sensitivity for nodal metastases in oesophageal cancer with combination of smaller size and lymph node axial ratio

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jianfang [Chinese Academy of Medical Sciences and Peking Union Medical College, National Cancer Center/Cancer Hospital, Beijing (China); Capital Medical University Electric Power Teaching Hospital, Beijing (China); Wang, Zhu; Qu, Dong; Yao, Libo [Chinese Academy of Medical Sciences and Peking Union Medical College, National Cancer Center/Cancer Hospital, Beijing (China); Shao, Huafei [Affiliated Yantai Yuhuangding Hospital of Qingdao University Medical College, Yantai (China); Liu, Jian [Meitan General Hospital, Beijing (China)

    2018-01-15

    To investigate the value of CT with inclusion of smaller lymph node (LN) sizes and axial ratio to improve the sensitivity in diagnosis of regional lymph node metastases in oesophageal squamous cell carcinoma (OSCC). The contrast-enhanced multidetector row spiral CT (MDCT) multiplanar reconstruction images of 204 patients with OSCC were retrospectively analysed. The long-axis and short-axis diameters of the regional LNs were measured and axial ratios were calculated (short-axis/long-axis diameters). Nodes were considered round if the axial ratio exceeded the optimal LN axial ratio, which was determined by receiver operating characteristic analysis. A positive predictive value (PPV) exceeding 50% is needed. This was achieved only with LNs larger than 9 mm in short-axis diameter, but nodes of this size were rare (sensitivity 37.3%, specificity 96.4%, accuracy 85.8%). If those round nodes (axial ratio exceeding 0.66) between 7 mm and 9 mm in size were considered metastases as well, it might improve the sensitivity to 67.2% with a PPV of 63.9% (specificity 91.6%, accuracy 87.2%). Combination of a smaller size and axial ratio for LNs in MDCT as criteria improves the detection sensitivity for LN metastases in OSCC. (orig.)

  14. Action video games and improved attentional control: Disentangling selection- and response-based processes.

    Science.gov (United States)

    Chisholm, Joseph D; Kingstone, Alan

    2015-10-01

    Research has demonstrated that experience with action video games is associated with improvements in a host of cognitive tasks. Evidence from paradigms that assess aspects of attention has suggested that action video game players (AVGPs) possess greater control over the allocation of attentional resources than do non-video-game players (NVGPs). Using a compound search task that teased apart selection- and response-based processes (Duncan, 1985), we required participants to perform an oculomotor capture task in which they made saccades to a uniquely colored target (selection-based process) and then produced a manual directional response based on information within the target (response-based process). We replicated the finding that AVGPs are less susceptible to attentional distraction and, critically, revealed that AVGPs outperform NVGPs on both selection-based and response-based processes. These results not only are consistent with the improved-attentional-control account of AVGP benefits, but they suggest that the benefit of action video game playing extends across the full breadth of attention-mediated stimulus-response processes that impact human performance.

  15. A New Manufacturing Service Selection and Composition Method Using Improved Flower Pollination Algorithm

    Directory of Open Access Journals (Sweden)

    Wenyu Zhang

    2016-01-01

    Full Text Available With an increasing number of manufacturing services, the means by which to select and compose these manufacturing services have become a challenging problem. It can be regarded as a multiobjective optimization problem that involves a variety of conflicting quality of service (QoS attributes. In this study, a multiobjective optimization model of manufacturing service composition is presented that is based on QoS and an environmental index. Next, the skyline operator is applied to reduce the solution space. And then a new method called improved Flower Pollination Algorithm (FPA is proposed for solving the problem of manufacturing service selection and composition. The improved FPA enhances the performance of basic FPA by combining the latter with crossover and mutation operators of the Differential Evolution (DE algorithm. Finally, a case study is conducted to compare the proposed method with other evolutionary algorithms, including the Genetic Algorithm, DE, basic FPA, and extended FPA. The experimental results reveal that the proposed method performs best at solving the problem of manufacturing service selection and composition.

  16. Long-term treatment with losartan versus atenolol improves insulin sensitivity in hypertension: ICARUS, a LIFE substudy

    DEFF Research Database (Denmark)

    Olsen, Michael H; Fossum, Eigil; Høieggen, Aud

    2005-01-01

    Hypertension and insulin resistance might be associated through peripheral vascular hypertrophy/rarefaction which compromises skeletal muscle blood flow and decreases glucose uptake, inducing insulin resistance. We hypothesized that treatment with losartan as compared to atenolol would improve...... insulin sensitivity through regression of peripheral vascular hypertrophy/rarefaction....

  17. Chicken lines divergently selected for antibody responses to sheep red blood cells show line-specific differences in sensitivity to immunomodulation by diet. Part I: Humoral parameters

    NARCIS (Netherlands)

    Adriaansen-Tennekes, R.; Vries Reilingh, de G.; Nieuwland, M.G.B.; Parmentier, H.K.; Savelkoul, H.F.J.

    2009-01-01

    Individual differences in nutrient sensitivity have been suggested to be related with differences in stress sensitivity. Here we used layer hens divergently selected for high and low specific antibody responses to SRBC (i.e., low line hens and high line hens), reflecting a genetically based

  18. Global proteomics profiling improves drug sensitivity prediction: results from a multi-omics, pan-cancer modeling approach.

    Science.gov (United States)

    Ali, Mehreen; Khan, Suleiman A; Wennerberg, Krister; Aittokallio, Tero

    2018-04-15

    Proteomics profiling is increasingly being used for molecular stratification of cancer patients and cell-line panels. However, systematic assessment of the predictive power of large-scale proteomic technologies across various drug classes and cancer types is currently lacking. To that end, we carried out the first pan-cancer, multi-omics comparative analysis of the relative performance of two proteomic technologies, targeted reverse phase protein array (RPPA) and global mass spectrometry (MS), in terms of their accuracy for predicting the sensitivity of cancer cells to both cytotoxic chemotherapeutics and molecularly targeted anticancer compounds. Our results in two cell-line panels demonstrate how MS profiling improves drug response predictions beyond that of the RPPA or the other omics profiles when used alone. However, frequent missing MS data values complicate its use in predictive modeling and required additional filtering, such as focusing on completely measured or known oncoproteins, to obtain maximal predictive performance. Rather strikingly, the two proteomics profiles provided complementary predictive signal both for the cytotoxic and targeted compounds. Further, information about the cellular-abundance of primary target proteins was found critical for predicting the response of targeted compounds, although the non-target features also contributed significantly to the predictive power. The clinical relevance of the selected protein markers was confirmed in cancer patient data. These results provide novel insights into the relative performance and optimal use of the widely applied proteomic technologies, MS and RPPA, which should prove useful in translational applications, such as defining the best combination of omics technologies and marker panels for understanding and predicting drug sensitivities in cancer patients. Processed datasets, R as well as Matlab implementations of the methods are available at https://github.com/mehr-een/bemkl-rbps. mehreen

  19. Molecularly imprinted fluorescent probe based on FRET for selective and sensitive detection of doxorubicin

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhifeng, E-mail: 897061147@qq.com [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Deng, Peihong; Li, Junhua [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Xu, Li [Department of Applied Chemistry, College of Materials and Energy, South China Agricultural University, Guangzhou 510642 (China); Tang, Siping [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China)

    2017-04-15

    Highlights: • FRET-based molecularly imprinted probe for detection of doxorubicin was prepared. • The detection limit of the probe was 13.8 nM for doxorubicin. • The FRET-based probe had a higher selectivity for the template than ordinary MIMs. - Abstract: In this work, a new type of fluorescent probe for detection of doxorubicin has been constructed by the combined use of fluorescence resonance energy transfer (FRET) technology and molecular imprinting technique (MIT). Using doxorubicin as the template, the molecularly imprinted polymer thin layer was fabricated on the surfaces of carbon dot (CD) modified silica by sol-gel polymerization. The excitation energy of the fluorescent donor (CDs) could be transferred to the fluorescent acceptor (doxorubicin). The FRET based fluorescent probe demonstrated high sensitivity and selectivity for doxorubicin. The detection limit was 13.8 nM. The fluorescent probe was successfully applied for detecting doxorubicin in doxorubicin-spiked plasmas with a recovery of 96.8–103.8%, a relative standard deviation (RSD) of 1.3–2.8%. The strategy for construction of FRET-based molecularly imprinted materials developed in this work is very promising for analytical applications.

  20. Structural Investigations using a position sensitive Neutron Detector

    International Nuclear Information System (INIS)

    Fruchart, D.; Anne, M.; Wolfers, P.; Lartigue, C.; Roudaut, E.

    1986-01-01

    In the accurate determination of the location of lights atoms such as hydrogen in a metal matrix, several types of difficulty may be encountered. Experimentally, neutron diffraction is the most convenient method for such a structure determination. The use of Position Sensitive Detectors is discussed, and selected examples illustrate the advantages and drawbacks of this type of instrument. Judging from present results, significant improvements in recording technique, data collection and reduction, and structure refinement may be obtained in the near future

  1. Toward Improved Force-Field Accuracy through Sensitivity Analysis of Host-Guest Binding Thermodynamics

    Science.gov (United States)

    Yin, Jian; Fenley, Andrew T.; Henriksen, Niel M.; Gilson, Michael K.

    2015-01-01

    Improving the capability of atomistic computer models to predict the thermodynamics of noncovalent binding is critical for successful structure-based drug design, and the accuracy of such calculations remains limited by non-optimal force field parameters. Ideally, one would incorporate protein-ligand affinity data into force field parametrization, but this would be inefficient and costly. We now demonstrate that sensitivity analysis can be used to efficiently tune Lennard-Jones parameters of aqueous host-guest systems for increasingly accurate calculations of binding enthalpy. These results highlight the promise of a comprehensive use of calorimetric host-guest binding data, along with existing validation data sets, to improve force field parameters for the simulation of noncovalent binding, with the ultimate goal of making protein-ligand modeling more accurate and hence speeding drug discovery. PMID:26181208

  2. Parameter Optimization for Selected Correlation Analysis of Intracranial Pathophysiology

    Directory of Open Access Journals (Sweden)

    Rupert Faltermeier

    2015-01-01

    Full Text Available Recently we proposed a mathematical tool set, called selected correlation analysis, that reliably detects positive and negative correlations between arterial blood pressure (ABP and intracranial pressure (ICP. Such correlations are associated with severe impairment of the cerebral autoregulation and intracranial compliance, as predicted by a mathematical model. The time resolved selected correlation analysis is based on a windowing technique combined with Fourier-based coherence calculations and therefore depends on several parameters. For real time application of this method at an ICU it is inevitable to adjust this mathematical tool for high sensitivity and distinct reliability. In this study, we will introduce a method to optimize the parameters of the selected correlation analysis by correlating an index, called selected correlation positive (SCP, with the outcome of the patients represented by the Glasgow Outcome Scale (GOS. For that purpose, the data of twenty-five patients were used to calculate the SCP value for each patient and multitude of feasible parameter sets of the selected correlation analysis. It could be shown that an optimized set of parameters is able to improve the sensitivity of the method by a factor greater than four in comparison to our first analyses.

  3. Parameter Optimization for Selected Correlation Analysis of Intracranial Pathophysiology.

    Science.gov (United States)

    Faltermeier, Rupert; Proescholdt, Martin A; Bele, Sylvia; Brawanski, Alexander

    2015-01-01

    Recently we proposed a mathematical tool set, called selected correlation analysis, that reliably detects positive and negative correlations between arterial blood pressure (ABP) and intracranial pressure (ICP). Such correlations are associated with severe impairment of the cerebral autoregulation and intracranial compliance, as predicted by a mathematical model. The time resolved selected correlation analysis is based on a windowing technique combined with Fourier-based coherence calculations and therefore depends on several parameters. For real time application of this method at an ICU it is inevitable to adjust this mathematical tool for high sensitivity and distinct reliability. In this study, we will introduce a method to optimize the parameters of the selected correlation analysis by correlating an index, called selected correlation positive (SCP), with the outcome of the patients represented by the Glasgow Outcome Scale (GOS). For that purpose, the data of twenty-five patients were used to calculate the SCP value for each patient and multitude of feasible parameter sets of the selected correlation analysis. It could be shown that an optimized set of parameters is able to improve the sensitivity of the method by a factor greater than four in comparison to our first analyses.

  4. Selection for production-related traits in Pelargonium zonale: improved design and analysis make all the difference.

    Science.gov (United States)

    Molenaar, Heike; Glawe, Martin; Boehm, Robert; Piepho, Hans-Peter

    2017-01-01

    Ornamental plant variety improvement is limited by current phenotyping approaches and neglected use of experimental designs. The present study was conducted to show the benefits of using an experimental design and corresponding analysis in ornamental breeding regarding simulated response to selection in Pelargonium zonale for production-related traits. This required establishment of phenotyping protocols for root formation and stem cutting counts, with which 974 genotypes were assessed in a two-phase experimental design. The present paper evaluates this protocol. The possibility of varietal improvement through indirect selection on secondary traits such as branch count and flower count was assessed by genetic correlations. Simulated response to selection varied greatly, depending on the genotypic variances of the breeding population and traits. A varietal improvement of over 20% is possible for stem cutting count, root formation, branch count and flower count. In contrast, indirect selection of stem cutting count by branch count or flower count was found to be ineffective. The established phenotypic protocols and two-phase experimental designs are valuable tools for breeding of P. zonale .

  5. Selective and sensitive fluorescent sensor for Pd2+ using coumarin 460 for real-time and biological applications.

    Science.gov (United States)

    Ashwin, Bosco Christin Maria Arputham; Sivaraman, Gandhi; Stalin, Thambusamy; Yuvakkumar, Rathinam; Muthu Mareeswaran, Paulpandian

    2018-05-03

    The efficient fluorescent property of coumarin 460 (C460) is utilized to sense the Pd 2+ selectively and sensitively. Fabrication of a sensor strip using commercial adhesive tape is achieved and the detection of Pd 2+ is attempted using a handy UV torch. The naked eye detection in solution state using UV chamber is also attempted. The calculated high binding constant values support the strong stable complex formation of Pd 2+ with C460. The detection limit up to 2.5 × 10 -7  M is achieved using fluorescence spectrometer, which is considerably low from the WHO's recommendation. The response of coumarin 460 with various cations also studied. The quenching is further studied by the lifetime measurements. The binding mechanism is clearly explained by the 1 H NMR titration. The sensing mechanism is established as ICT. C460 strip's Pd 2+ quenching detection is further confirmed by solid-state PL study. The in-vitro response of Pd 2+ in a living cell is also studied using fluorescent imaging studies by means of HeLa cell lines and this probe is very compatible with biological environments. It could be applicable to sense trace amounts of a Pd 2+ ion from various industries. Compared with previous reports, this one is very cheap, sensitive, selective and suitable for biological systems. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Improved sensitivity and limit-of-detection of lateral flow devices using spatial constrictions of the flow-path.

    Science.gov (United States)

    Katis, Ioannis N; He, Peijun J W; Eason, Robert W; Sones, Collin L

    2018-05-03

    We report on the use of a laser-direct write (LDW) technique that allows the fabrication of lateral flow devices with enhanced sensitivity and limit of detection. This manufacturing technique comprises the dispensing of a liquid photopolymer at specific regions of a nitrocellulose membrane and its subsequent photopolymerisation to create impermeable walls inside the volume of the membrane. These polymerised structures are intentionally designed to create fluidic channels which are constricted over a specific length that spans the test zone within which the sample interacts with pre-deposited reagents. Experiments were conducted to show how these constrictions alter the fluid flow rate and the test zone area within the constricted channel geometries. The slower flow rate and smaller test zone area result in the increased sensitivity and lowered limit of detection for these devices. We have quantified these via the improved performance of a C-Reactive Protein (CRP) sandwich assay on our lateral flow devices with constricted flow paths which demonstrate an improvement in its sensitivity by 62x and in its limit of detection by 30x when compared to a standard lateral flow CRP device. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  7. Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response

    Energy Technology Data Exchange (ETDEWEB)

    Chain, J N M; McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, K7L 3N6 (Canada); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, V8W 3P6 (Canada); Schreiner, L J, E-mail: kim.mcauley@chee.queensu.ca [Cancer Centre of Southeastern Ontario, Kingston, K7L 5P9 (Canada)

    2011-04-07

    This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range ({approx}0.88 H Gy{sup -1}) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent ({approx}0.80 H Gy{sup -1}). This new gel formulation results in enhanced dose resolution ({approx}0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.

  8. Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response

    International Nuclear Information System (INIS)

    Chain, J N M; McAuley, K B; Jirasek, A; Schreiner, L J

    2011-01-01

    This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range (∼0.88 H Gy -1 ) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent (∼0.80 H Gy -1 ). This new gel formulation results in enhanced dose resolution (∼0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.

  9. The impact of the Brazilian family health strategy on selected primary care sensitive conditions: A systematic review.

    Directory of Open Access Journals (Sweden)

    Mayara Lisboa Bastos

    Full Text Available Brazil has the largest public health-system in the world, with 120 million people covered by its free primary care services. The Family Health Strategy (FHS is the main primary care model, but there is no consensus on its impact on health outcomes. We systematically reviewed published evidence regarding the impact of the Brazilian FHS on selective primary care sensitive conditions (PCSC.We searched Medline, Web of Science and Lilacs in May 2016 using key words in Portuguese and English, without language restriction. We included studies if intervention was the FHS; comparison was either different levels of FHS coverage or other primary health care service models; outcomes were the selected PCSC; and results were adjusted for relevant sanitary and socioeconomic variables, including the national conditional cash transfer program (Bolsa Familia. Due to differences in methods and outcomes reported, pooling of results was not possible.Of 1831 records found, 31 met our inclusion criteria. Of these, 25 were ecological studies. Twenty-one employed longitudinal quasi-experimental methods, 27 compared different levels the FHS coverage, whilst four compared the FHS versus other models of primary care. Fourteen studies found an association between higher FHS coverage and lower post-neonatal and child mortality. When the effect of Bolsa Familia was accounted for, the effect of the FHS on child mortality was greater. In 13 studies about hospitalizations due to PCSC, no clear pattern of association was found. In four studies, there was no effect on child and elderly vaccination or low-birth weight. No included studies addressed breast-feeding, dengue, HIV/AIDS and other neglected infectious diseases.Among these ecological studies with limited quality evidence, increasing coverage by the FHS was consistently associated with improvements in child mortality. Scarce evidence on other health outcomes, hospitalization and synergies with cash transfer was found.

  10. Selection of infectious medical waste disposal firms by using the analytic hierarchy process and sensitivity analysis

    International Nuclear Information System (INIS)

    Hsu, P.-F.; Wu, C.-R.; Li, Y.-T.

    2008-01-01

    While Taiwanese hospitals dispose of large amounts of medical waste to ensure sanitation and personal hygiene, doing so inefficiently creates potential environmental hazards and increases operational expenses. However, hospitals lack objective criteria to select the most appropriate waste disposal firm and evaluate its performance, instead relying on their own subjective judgment and previous experiences. Therefore, this work presents an analytic hierarchy process (AHP) method to objectively select medical waste disposal firms based on the results of interviews with experts in the field, thus reducing overhead costs and enhancing medical waste management. An appropriate weight criterion based on AHP is derived to assess the effectiveness of medical waste disposal firms. The proposed AHP-based method offers a more efficient and precise means of selecting medical waste firms than subjective assessment methods do, thus reducing the potential risks for hospitals. Analysis results indicate that the medical sector selects the most appropriate infectious medical waste disposal firm based on the following rank: matching degree, contractor's qualifications, contractor's service capability, contractor's equipment and economic factors. By providing hospitals with an effective means of evaluating medical waste disposal firms, the proposed AHP method can reduce overhead costs and enable medical waste management to understand the market demand in the health sector. Moreover, performed through use of Expert Choice software, sensitivity analysis can survey the criterion weight of the degree of influence with an alternative hierarchy

  11. Improved sensitivity high-definition interline CCD using the KODAK TRUESENSE color filter pattern

    Science.gov (United States)

    DiBella, James; Andreghetti, Marco; Enge, Amy; Chen, William; Stanka, Timothy; Kaser, Robert

    2010-01-01

    The KODAK TRUESENSE Color Filter Pattern has technology that for the first time is applied to a commercially available interline CCD. This 2/3" true-HD sensor will be described along with its performance attributes, including sensitivity improvement as compared to the Bayer CFA version of the same sensor. In addition, an overview of the system developed for demonstration and evaluation will be provided. Examples of the benefits of the new technology in specific applications including surveillance and intelligent traffic systems will be discussed.

  12. Genomic Selection Improves Heat Tolerance in Dairy Cattle

    Science.gov (United States)

    Garner, J. B.; Douglas, M. L.; Williams, S. R. O; Wales, W. J.; Marett, L. C.; Nguyen, T. T. T.; Reich, C. M.; Hayes, B. J.

    2016-01-01

    Dairy products are a key source of valuable proteins and fats for many millions of people worldwide. Dairy cattle are highly susceptible to heat-stress induced decline in milk production, and as the frequency and duration of heat-stress events increases, the long term security of nutrition from dairy products is threatened. Identification of dairy cattle more tolerant of heat stress conditions would be an important progression towards breeding better adapted dairy herds to future climates. Breeding for heat tolerance could be accelerated with genomic selection, using genome wide DNA markers that predict tolerance to heat stress. Here we demonstrate the value of genomic predictions for heat tolerance in cohorts of Holstein cows predicted to be heat tolerant and heat susceptible using controlled-climate chambers simulating a moderate heatwave event. Not only was the heat challenge stimulated decline in milk production less in cows genomically predicted to be heat-tolerant, physiological indicators such as rectal and intra-vaginal temperatures had reduced increases over the 4 day heat challenge. This demonstrates that genomic selection for heat tolerance in dairy cattle is a step towards securing a valuable source of nutrition and improving animal welfare facing a future with predicted increases in heat stress events. PMID:27682591

  13. Loss in MCL-1 function sensitizes non-Hodgkin's lymphoma cell lines to the BCL-2-selective inhibitor venetoclax (ABT-199)

    International Nuclear Information System (INIS)

    Phillips, D C; Xiao, Y; Lam, L T; Litvinovich, E; Roberts-Rapp, L; Souers, A J; Leverson, J D

    2015-01-01

    As a population, non-Hodgkin's lymphoma (NHL) cell lines positive for the t(14;18) translocation and/or possessing elevated BCL2 copy number (CN; BCL2 High ) are exquisitely sensitive to navitoclax or the B-cell lymphoma protein-2 (BCL-2)-selective inhibitor venetoclax. Despite this, some BCL2 High cell lines remain resistant to either agent. Here we show that the MCL-1-specific inhibitor A-1210477 sensitizes these cell lines to navitoclax. Chemical segregation of this synergy with the BCL-2-selective inhibitor venetoclax or BCL-X L -selective inhibitor A-1155463 indicated that MCL-1 and BCL-2 are the two key anti-apoptotic targets for sensitization. Similarly, the CDK inhibitor flavopiridol downregulated MCL-1 expression and synergized with venetoclax in BCL2 High NHL cell lines to a similar extent as A-1210477. A-1210477 also synergized with navitoclax in the majority of BCL2 Low NHL cell lines. However, chemical segregation with venetoclax or A-1155463 revealed that synergy was driven by BCL-X L inhibition in this population. Collectively these data emphasize that BCL2 status is predictive of venetoclax potency in NHL not only as a single agent, but also in the adjuvant setting with anti-tumorigenic agents that inhibit MCL-1 function. These studies also potentially identify a patient population (BCL2 Low ) that could benefit from BCL-X L (navitoclax)-driven combination therapy

  14. Improving the Selectivity of the ISOLDE Resonance Ionization Laser Ion Source and In-Source Laser Spectroscopy of Polonium

    CERN Document Server

    Fink, Daniel Andreas; Jochim, Selim

    Exotic atomic nuclei far away from stability are fascinating objects to be studied in many scientic elds such as atomic-, nuclear-, and astrophysics. Since these are often short-lived isotopes, it is necessary to couple their production with immediate extraction and delivery to an experiment. This is the purpose of the on-line isotope separator facility, ISOLDE, at CERN. An essential aspect of this laboratory is the Resonance Ionization Laser Ion Source (RILIS) because it provides a fast and highly selective means of ionizing the reaction products. This technique is also a sensitive laser-spectroscopy tool for the development and improvement of electron excitation schemes for the resonant laser photoionization and the study of the nuclear structure or fundamental atomic physics. Each of these aspects of the RILIS applications are subjects of this thesis work: a new device for the suppression of unwanted surface ionized contaminants in RILIS ion beams, known as the Laser Ion Source and Trap (LIST), was impleme...

  15. The admissible portfolio selection problem with transaction costs and an improved PSO algorithm

    Science.gov (United States)

    Chen, Wei; Zhang, Wei-Guo

    2010-05-01

    In this paper, we discuss the portfolio selection problem with transaction costs under the assumption that there exist admissible errors on expected returns and risks of assets. We propose a new admissible efficient portfolio selection model and design an improved particle swarm optimization (PSO) algorithm because traditional optimization algorithms fail to work efficiently for our proposed problem. Finally, we offer a numerical example to illustrate the proposed effective approaches and compare the admissible portfolio efficient frontiers under different constraints.

  16. Resistin, an adipokine, may affect the improvement of insulin sensitivity in the metabolic syndrome patient treated with metformin.

    Science.gov (United States)

    Yuan, Hong; Weng, Chunyan; Yang, Youbo; Huang, Lihua; Xing, Xiaowei

    2013-12-01

    The metabolic syndrome (MS) is a cluster of metabolic disorders arising from insulin resistance, characterized by the presence of central obesity, impaired fasting glucose level, dyslipidemia and hypertension. As the first-line medication, metformin is commonly used for MS to reduce insulin resistance. Comparing with rosiglitazone, metformin does not increase cardiovascular mortality risk in patients with MS. However, metformin is not good enough in improving insulin sensitivity. Its molecular mechanism is still not clear. Recent studies have demonstrated that resistin, an adipokine, could induce IR by both AMPK-dependent and AMPK-independent pathways. Though there were conflicting findings of resistin in metabolic syndrome or type 2 diabetes mellitus in different studies, resistin was significant decreased in the rosiglitazone treated patients than in the metformin-treated patients in most of studies. Here, we hypothesized that resistin, an adipokine, may affect the improvement of insulin sensitivity in the metabolic syndrome patient treated with metformin. This hypothesis could explain why rosiglitazone is superior to metformin in enhancement of insulin sensitivity. Copyright © 2013. Published by Elsevier Ltd.

  17. Improving inspection reliability through operator selection and training

    International Nuclear Information System (INIS)

    McGrath, Bernard; Carter, Luke

    2013-01-01

    A number of years ago the UK's Health and Safety Executive sponsored a series of three PANI projects investigating the application of manual ultrasonics, which endeavoured to establish the necessary steps that ensure a reliable inspection is performed. The results of the three projects were each reported separately on completion and also presented at number of international conferences. This paper summarises the results of these projects from the point of view of operator performance. The correlation of operator ultrasonic performance with results of aptitude tests is presented along with observations on the impact of training and qualifications of the operators. The results lead to conclusions on how the selection and training of operators could be modified to improve reliability of inspections.

  18. Co-sensitization of ZnO by CdS quantum dots in natural dye-sensitized solar cells with polymeric electrolytes to improve the cell stability

    Energy Technology Data Exchange (ETDEWEB)

    Junhom, W.; Magaraphan, R. [Polymer Processing and Polymer Nanomaterials Research Unit, Petroleum and Petrochemical College, Chulalongkorn University, Bangkok (Thailand)

    2015-05-22

    The CdS quantum dots (QDs) were deposited on ZnO layer by chemical bath deposition method to absorb light in the shorter wavelength region and used as photoanode in the dye sensitized solar cell (DSSCs) with natural dye extracted from Noni leaves. Microstructures of CdS-ZnO from various dipping time were characterized by XRD, FE-SEM and EDX. The results showed that the CdS is hexagonal structure and the amount of CdS increases when the dipping time increases. The maximal conversion efficiency of 0.292% was achieved by the DSSCs based on CdS QDs-sensitized ZnO film obtained from 9 min-dipping time. Furthermore, the stability of DSSCs was improved by using polymeric electrolyte. Poly (acrylic acid) (PAA) and Polyacrylamide (PAM) were introduced to CdS QDs-sensitized ZnO film from 9 min-dipping time. Each polymeric electrolyte was prepared by swelling from 0.1-2.0 %w in H2O. The maximal conversion efficiency of 0.207% was achieved for DSSCs based on CdS QDs-sensitized ZnO film with PAM 1.0% and the conversion efficiency was decreased 25% when it was left for1 hr.

  19. Improved performance of CdSe/CdS/PbS co-sensitized solar cell with double-layered TiO2 films as photoanode

    Science.gov (United States)

    Zhang, Xiaolong; Lin, Yu; Wu, Jihuai; Jing, Jing; Fang, Biaopeng

    2017-07-01

    Improving the photovoltaic performance of CdSe/CdS/PbS co-sensitized double-layered TiO2 solar cells is reported. Double-layered TiO2 films with TiO2 microspheres as the light blocking layers were prepared. PbS, CdS and CdSe quantum dots (QDs) were assembled onto TiO2 photoanodes by simple successive ionic layer absorption and reaction (SILAR) to fabricate CdSe/CdS/PbS co-sensitized solar cells. An improved power conversion efficiency (PCE) of 5.11% was achieved for CdSe/CdS/PbS co-sensitized solar cells at one sun illumination (AM 1.5 G, 100 mW cm-2), which had an improvement of 22.6% over that of the CdSe/CdS co-sensitized solar cells (4.17%). This enhancement is mainly attributed to their better ability of the absorption of solar light with the existence of PbS QDs, the reduction of charge recombination of the excited electron and longer lifetime of electrons, which have been proved with the photovoltaic studies and electrochemical impedance spectroscopy (EIS).

  20. Proof of Concept: Matrix metalloproteinase inhibitor decreases inflammation and improves muscle insulin sensitivity in people with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Frankwich Karen

    2012-10-01

    Full Text Available Abstract Background Obesity is a state of subclinical inflammation resulting in loss of function of insulin receptors and decreased insulin sensitivity. Inhibition of the inflammatory enzymes, matrix metalloproteinases (MMPs, for 6 months in rodent models restores insulin receptor function and insulin sensitivity. Methods This 12-week double-blind, randomized, placebo (PL-controlled proof-of-concept study was performed to determine if the MMP inhibitor (MMPI, doxycycline, decreased global markers of inflammation and enhanced muscle insulin sensitivity in obese people with type 2 diabetes (DM2. The study included non-DM2 controls (n = 15, and DM2 subjects randomized to PL (n = 13 or doxycycline 100 mg twice daily (MMPI; n = 11. All participants were evaluated on Day 1; MMPI and PL groups were also evaluated after 84 days of treatment. Results There was a significant decrease in inflammatory markers C-reactive protein (P  Conclusions This study demonstrated short term treatment of people with diabetes with an MMPI resulted in decreased inflammation and improved insulin sensitivity. Larger, longer studies are warranted to determine if doxycycline can improve glucose control in people with diabetes. Trial Registration Clinicaltrials.gov NCT01375491

  1. Trial application of PRATOOL: Performance of sensitivity studies on service water systems

    International Nuclear Information System (INIS)

    Gregg, R.E.; Wood, S.T.

    1991-03-01

    PRATOOL is a computer program developed to supplement the Integrated Reliability and Risk Analysis System (IRRAS) probabilistic risk assessment (PRA) computer program. It is intended to be a tool for performing PRA sensitivity analyses. This will allow a PRA's results to be easily reevaluated to show its sensitivity to changing parameter (system, component type, basic event, etc.) values (i.e., failure rates). This report documents a trial application of PRATOOL. It evaluates the sensitivity of core damage frequency to service water system availability at several nuclear power plants. For the purpose of this trail application of PRATOOL, service water system sensitivity studies were performed using the results of several NUREG- 1150 PRAs. These plants were chosen because their PRAs were already loaded into the IRRAS data base. Therefore, they are readily available for this type of study. PRATOOL contains a small subset of the functions provided by IRRAS. The user can select sets of parameters that will act as the bases for sensitivity analyses. Depending on the PRA used, the parameters selected can include: systems, component types, trains, locations, failure modes, and basic events. It will also perform and AND-ing operation on selected parameters. This allows the user define any number of possible combinations of parameters. The results of the four sensitivity studies would tend to indicate that the SWS availability is important for BWRs but unimportant for PWRs. Both BWRs showed significant increases in CDF if their SWS failure rates are allowed to increase. From the results of the four sensitivity studies, it is interesting to note that no improvements made to any of the SWSs' failure rates would result in a significant decrease on CDF. 10 figs

  2. New Variants of Tomato Thymidine Kinase 1 Selected for Increased Sensitivity of E. coli KY895 towards Azidothymidine

    International Nuclear Information System (INIS)

    Slot Christiansen, Louise; Egeblad, Louise; Munch-Petersen, Birgitte; Piškur, Jure; Knecht, Wolfgang

    2015-01-01

    Nucleoside analogues (NA) are prodrugs that are phosphorylated by deoxyribonucleoside kinases (dNKs) as the first step towards a compound toxic to the cell. During the last 20 years, research around dNKs has gone into new organisms other than mammals and viruses. Newly discovered dNKs have been tested as enzymes for suicide gene therapy. The tomato thymidine kinase 1 (ToTK1) is a dNK that has been selected for its in vitro kinetic properties and then successfully been tested in vivo for the treatment of malignant glioma. We present the selection of two improved variants of ToTK1 generated by random protein engineering for suicide gene therapy with the NA azidothymidine (AZT). We describe their selection, recombinant production and a subsequent kinetic and biochemical characterization. Their improved performance in killing of E. coli KY895 is accompanied by an increase in specificity for the NA AZT over the natural substrate thymidine as well as a decrease in inhibition by dTTP, the end product of the nucleoside salvage pathway for thymidine. The understanding of the enzymatic properties improving the variants efficacy is instrumental to further develop dNKs for use in suicide gene therapy

  3. New Variants of Tomato Thymidine Kinase 1 Selected for Increased Sensitivity of E. coli KY895 towards Azidothymidine

    Energy Technology Data Exchange (ETDEWEB)

    Slot Christiansen, Louise [Department of Biology, Lund University, Lund 22362 (Sweden); Lund Protein Production Platform, Lund University, Lund 22362 (Sweden); Egeblad, Louise [Lund Protein Production Platform, Lund University, Lund 22362 (Sweden); Munch-Petersen, Birgitte [Department of Science, Systems and Models, Roskilde University, Roskilde 4000 (Denmark); Piškur, Jure [Department of Biology, Lund University, Lund 22362 (Sweden); Knecht, Wolfgang, E-mail: Louise.Slot_Christiansen@biol.lu.se [Department of Biology, Lund University, Lund 22362 (Sweden); Lund Protein Production Platform, Lund University, Lund 22362 (Sweden)

    2015-06-08

    Nucleoside analogues (NA) are prodrugs that are phosphorylated by deoxyribonucleoside kinases (dNKs) as the first step towards a compound toxic to the cell. During the last 20 years, research around dNKs has gone into new organisms other than mammals and viruses. Newly discovered dNKs have been tested as enzymes for suicide gene therapy. The tomato thymidine kinase 1 (ToTK1) is a dNK that has been selected for its in vitro kinetic properties and then successfully been tested in vivo for the treatment of malignant glioma. We present the selection of two improved variants of ToTK1 generated by random protein engineering for suicide gene therapy with the NA azidothymidine (AZT). We describe their selection, recombinant production and a subsequent kinetic and biochemical characterization. Their improved performance in killing of E. coli KY895 is accompanied by an increase in specificity for the NA AZT over the natural substrate thymidine as well as a decrease in inhibition by dTTP, the end product of the nucleoside salvage pathway for thymidine. The understanding of the enzymatic properties improving the variants efficacy is instrumental to further develop dNKs for use in suicide gene therapy.

  4. Context Sensitive Modeling of Cancer Drug Sensitivity.

    Directory of Open Access Journals (Sweden)

    Bo-Juen Chen

    Full Text Available Recent screening of drug sensitivity in large panels of cancer cell lines provides a valuable resource towards developing algorithms that predict drug response. Since more samples provide increased statistical power, most approaches to prediction of drug sensitivity pool multiple cancer types together without distinction. However, pan-cancer results can be misleading due to the confounding effects of tissues or cancer subtypes. On the other hand, independent analysis for each cancer-type is hampered by small sample size. To balance this trade-off, we present CHER (Contextual Heterogeneity Enabled Regression, an algorithm that builds predictive models for drug sensitivity by selecting predictive genomic features and deciding which ones should-and should not-be shared across different cancers, tissues and drugs. CHER provides significantly more accurate models of drug sensitivity than comparable elastic-net-based models. Moreover, CHER provides better insight into the underlying biological processes by finding a sparse set of shared and type-specific genomic features.

  5. A Study of Nonlinear Elasticity Effects on Permeability of Stress Sensitive Shale Rocks Using an Improved Coupled Flow and Geomechanics Model: A Case Study of the Longmaxi Shale in China

    Directory of Open Access Journals (Sweden)

    Chenji Wei

    2018-02-01

    Full Text Available Gas transport in shale gas reservoirs is largely affected by rock properties such as permeability. These properties are often sensitive to the in-situ stress state changes. Accurate modeling of shale gas transport in shale reservoir rocks considering the stress sensitive effects on rock petrophysical properties is important for successful shale gas extraction. Nonlinear elasticity in stress sensitive reservoir rocks depicts the nonlinear stress-strain relationship, yet it is not thoroughly studied in previous reservoir modeling works. In this study, an improved coupled flow and geomechanics model that considers nonlinear elasticity is proposed. The model is based on finite element methods, and the nonlinear elasticity in the model is validated with experimental data on shale samples selected from the Longmaxi Formation in Sichuan Basin China. Numerical results indicate that, in stress sensitive shale rocks, nonlinear elasticity affects shale permeability, shale porosity, and distributions of effective stress and pore pressure. Elastic modulus change is dependent on not only in-situ stress state but also stress history path. Without considering nonlinear elasticity, the modeling of shale rock permeability in Longmaxi Formation can overestimate permeability values by 1.6 to 53 times.

  6. Sensitivity Analysis of FEAST-Metal Fuel Performance Code: Initial Results

    International Nuclear Information System (INIS)

    Edelmann, Paul Guy; Williams, Brian J.; Unal, Cetin; Yacout, Abdellatif

    2012-01-01

    This memo documents the completion of the LANL milestone, M3FT-12LA0202041, describing methodologies and initial results using FEAST-Metal. The FEAST-Metal code calculations for this work are being conducted at LANL in support of on-going activities related to sensitivity analysis of fuel performance codes. The objective is to identify important macroscopic parameters of interest to modeling and simulation of metallic fuel performance. This report summarizes our preliminary results for the sensitivity analysis using 6 calibration datasets for metallic fuel developed at ANL for EBR-II experiments. Sensitivity ranking methodology was deployed to narrow down the selected parameters for the current study. There are approximately 84 calibration parameters in the FEAST-Metal code, of which 32 were ultimately used in Phase II of this study. Preliminary results of this sensitivity analysis led to the following ranking of FEAST models for future calibration and improvements: fuel conductivity, fission gas transport/release, fuel creep, and precipitation kinetics. More validation data is needed to validate calibrated parameter distributions for future uncertainty quantification studies with FEAST-Metal. Results of this study also served to point out some code deficiencies and possible errors, and these are being investigated in order to determine root causes and to improve upon the existing code models.

  7. High-intensity interval training improves insulin sensitivity in older individuals.

    Science.gov (United States)

    Søgaard, D; Lund, M T; Scheuer, C M; Dehlbaek, M S; Dideriksen, S G; Abildskov, C V; Christensen, K K; Dohlmann, T L; Larsen, S; Vigelsø, A H; Dela, F; Helge, J W

    2018-04-01

    Metabolic health may deteriorate with age as a result of altered body composition and decreased physical activity. Endurance exercise is known to counter these changes delaying or even preventing onset of metabolic diseases. High-intensity interval training (HIIT) is a time efficient alternative to regular endurance exercise, and the aim of this study was to investigate the metabolic benefit of HIIT in older subjects. Twenty-two sedentary male (n = 11) and female (n = 11) subjects aged 63 ± 1 years performed HIIT training three times/week for 6 weeks on a bicycle ergometer. Each HIIT session consisted of five 1-minute intervals interspersed with 1½-minute rest. Prior to the first and after the last HIIT session whole-body insulin sensitivity, measured by a hyperinsulinaemic-euglycaemic clamp, plasma lipid levels, HbA1c, glycaemic parameters, body composition and maximal oxygen uptake were assessed. Muscle biopsies were obtained wherefrom content of glycogen and proteins involved in muscle glucose handling were determined. Insulin sensitivity (P = .011) and maximal oxygen uptake increased (P body fat (P < .05) decreased after 6 weeks of HIIT. HbA1c decreased only in males (P = .001). Muscle glycogen content increased in both genders (P = .001) and in line GLUT4 (P < .05), glycogen synthase (P = .001) and hexokinase II (P < .05) content all increased. Six weeks of HIIT significantly improves metabolic health in older males and females by reducing age-related risk factors for cardiometabolic disease. © 2017 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  8. Improved profiling of estrogen metabolites by orbitrap LC/MS

    Science.gov (United States)

    Li, Xingnan; Franke, Adrian A.

    2015-01-01

    Estrogen metabolites are important biomarkers to evaluate cancer risks and metabolic diseases. Due to their low physiological levels, a sensitive and accurate method is required, especially for the quantitation of unconjugated forms of endogenous steroids and their metabolites in humans. Here, we evaluated various derivatives of estrogens for improved analysis by orbitrap LC/MS in human serum samples. A new chemical derivatization reagent was applied modifying phenolic steroids to form 1-methylimidazole-2-sulfonyl adducts. The method significantly improves the sensitivity 2–100 fold by full scan MS and targeted selected ion monitoring MS over other derivatization methods including, dansyl, picolinoyl, and pyridine-3-sulfonyl products. PMID:25543003

  9. Improving sensitivity of residual current transformers to high frequency earth fault currents

    Directory of Open Access Journals (Sweden)

    Czapp Stanislaw

    2017-09-01

    Full Text Available For protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed the modification in the structure of residual current devices. This modification improves sensitivity of residual current devices when high frequency earth fault current occurs. The test of the modified residual current device proved that the authors’ proposition is appropriate.

  10. MOVES regional level sensitivity analysis

    Science.gov (United States)

    2012-01-01

    The MOVES Regional Level Sensitivity Analysis was conducted to increase understanding of the operations of the MOVES Model in regional emissions analysis and to highlight the following: : the relative sensitivity of selected MOVES Model input paramet...

  11. Hydrazinonicotinic acid derivatization for selective ionization and improved glycan structure characterization by MALDI-MS.

    Science.gov (United States)

    Jiao, Jing; Yang, Lijun; Zhang, Ying; Lu, Haojie

    2015-08-21

    The analysis of glycan is important for understanding cell biology and disease processes because the glycans play a key role in many important biological behaviors, such as cell division, cellular localization, tumor immunology and inflammation. Nevertheless, it is still hard work to analyze glycans by MALDI-MS, which generally stems from the inherent low abundance and the low ionization efficiency of glycans. Moreover, the difficulty in generating informative fragmentations further hinders glycans structure characterization. In this work, hydrazinonicotinic acid (HYNIC) was used as a novel derivatized reagent for improved and selective detection of glycans. Through tagging the reducing terminus of glycans with the diazanyl group of HYNIC, significant enhancement of the ionization efficiency of glycans was achieved. After derivatization, the signal to noise ratio (S/N) of the maltoheptaose was improved by more than one order of magnitude in positive mode. HYNIC derivatization also allowed the sensitive detection of sialylated glycan in negative mode, with a 15 fold enhancement of S/N. Interestingly, it is noteworthy that the HYNIC reagent not only effectively labeled the reducing end of glycans in the presence of tryptic peptides, but also suppressed the ionization of peptides, enabling the direct detection of glycans from glycoprotein without separation. Therefore, analysis of glycans became easier due to the omission of a pre-separation step. Importantly, by using different acid reagents as the catalyst, derivatized product signals corresponding to [M + Na](+) or [M + H](+) were obtained respectively, which yield complementary fragmentation patterns for the structure elucidation of glycans. Finally, more than 40 N-glycans were successfully detected in 10 μL human serum using this method.

  12. Artemisia Extract Improves Insulin Sensitivity in Women With Gestational Diabetes Mellitus by Up-Regulating Adiponectin.

    Science.gov (United States)

    Sun, Xia; Sun, Hong; Zhang, Jing; Ji, Xianghong

    2016-12-01

    Gestational diabetes mellitus (GDM) has affected a great number of pregnant women worldwide. Artemisia extracts have been found to exhibit a potent antidiabetic effect in the treatment of type 2 diabetes mellitus. We aimed to examine the effects of Artemisia extract on insulin resistance and lipid profiles in pregnant GDM patients. Patients in their second trimester were randomly assigned to the Artemisia extract group (AE) or to a placebo group (PO). They were instructed to consume either AE or PO daily for a period of 10 weeks. Glucose and insulin profiles and adiponectin level were assessed at baseline (week 0) and after the treatment (week 10). Compared to the PO group, fasting plasma glucose, serum insulin levels, homeostasis model of assessment of insulin resistance (HOMA-IR), and β-cell function (HOMA-B) were significantly reduced in the AE group participants. Moreover, levels of circulating adiponectin were also significantly up-regulated in the AE group, which also positively contributed to improved insulin sensitivity. Daily administration of Artemisia extract improves insulin sensitivity by up-regulating adiponectin in women with gestational diabetes mellitus. © 2016, The American College of Clinical Pharmacology.

  13. Surface-selective laser sintering of thermolabile polymer particles using water as heating sensitizer

    Energy Technology Data Exchange (ETDEWEB)

    Antonov, E N; Krotova, L I; Minaev, N V; Minaeva, S A; Mironov, A V; Popov, V K [Institute on Laser and Information Technologies of the Russian Academy of Sciencies, Troitsk, Moscow (Russian Federation); Bagratashvili, V N [Department of Chemistry, M.V. Lomonosov Moscow State University, Moscow (Russian Federation)

    2015-11-30

    We report the implementation of a novel scheme for surface-selective laser sintering (SSLS) of polymer particles, based on using water as a sensitizer of laser heating and sintering of particles as well as laser radiation at a wavelength of 1.94 μm, corresponding to the strong absorption band of water. A method of sintering powders of poly(lactide-co-glycolide), a hydrophobic bioresorbable polymer, after modifying its surface with an aqueous solution of hyaluronic acid is developed. The sintering thresholds for wetted polymer are by 3 – 4 times lower than those for sintering in air. The presence of water restricts the temperature of the heated polymer, preventing its thermal destruction. Polymer matrices with a developed porous structure are obtained. The proposed SSLS method can be applied to produce bioresorbable polymer matrices for tissue engineering. (interaction of laser radiation with matter. laser plasma)

  14. Fluorescent metal-organic framework MIL-53(Al) for highly selective and sensitive detection of Fe3+ in aqueous solution.

    Science.gov (United States)

    Yang, Cheng-Xiong; Ren, Hu-Bo; Yan, Xiu-Ping

    2013-08-06

    Fluorescent metal-organic frameworks (MOFs) have received great attention in sensing application. Here, we report the exploration of fluorescent MIL-53(Al) for highly selective and sensitive detection of Fe(3+) in aqueous solution. The cation exchange between Fe(3+) and the framework metal ion Al(3+) in MIL-53(Al) led to the quenching of the fluorescence of MIL-53(Al) due to the transformation of strong-fluorescent MIL-53(Al) to weak-fluorescent MIL-53(Fe), allowing highly selective and sensitive detection of Fe(3+) in aqueous solution with a linear range of 3-200 μM and a detection limit of 0.9 μM. No interferences from 0.8 M Na(+); 0.35 M K(+); 11 mM Cu(2+); 10 mM Ni(2+); 6 mM Ca(2+), Pb(2+), and Al(3+); 5.5 mM Mn(2+); 5 mM Co(2+) and Cr(3+); 4 mM Hg(2+), Cd(2+), Zn(2+), and Mg(2+); 3 mM Fe(2+); 0.8 M Cl(-); 60 mM NO2(-) and NO3(-); 10 mM HPO4(2-), H2PO4(-), SO3(2-), SO4(2-), and HCOO(-); 8 mM CO3(2-), HCO3(-), and C2O4(2-); and 5 mM CH3COO(-) were found for the detection of 150 μM Fe(3+). The possible mechanism for the quenching effect of Fe(3+) on the fluorescence of MIL-53(Al) was elucidated by inductively coupled plasma-mass spectrometry, X-ray diffraction spectrometry, and Fourier transform infrared spectrometry. The specific cation exchange behavior between Fe(3+) and the framework Al(3+) along with the excellent stability of MIL-53(Al) allows highly selective and sensitive detection of Fe(3+) in aqueous solution. The developed method was applied to the determination of Fe(3+) in human urine samples with the quantitative spike recoveries from 98.2% to 106.2%.

  15. Selection of remedial alternatives for mine sites: a multicriteria decision analysis approach.

    Science.gov (United States)

    Betrie, Getnet D; Sadiq, Rehan; Morin, Kevin A; Tesfamariam, Solomon

    2013-04-15

    The selection of remedial alternatives for mine sites is a complex task because it involves multiple criteria and often with conflicting objectives. However, an existing framework used to select remedial alternatives lacks multicriteria decision analysis (MCDA) aids and does not consider uncertainty in the selection of alternatives. The objective of this paper is to improve the existing framework by introducing deterministic and probabilistic MCDA methods. The Preference Ranking Organization Method for Enrichment Evaluation (PROMETHEE) methods have been implemented in this study. The MCDA analysis involves processing inputs to the PROMETHEE methods that are identifying the alternatives, defining the criteria, defining the criteria weights using analytical hierarchical process (AHP), defining the probability distribution of criteria weights, and conducting Monte Carlo Simulation (MCS); running the PROMETHEE methods using these inputs; and conducting a sensitivity analysis. A case study was presented to demonstrate the improved framework at a mine site. The results showed that the improved framework provides a reliable way of selecting remedial alternatives as well as quantifying the impact of different criteria on selecting alternatives. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Sensitivity Analysis of Uncertainty Parameter based on MARS-LMR Code on SHRT-45R of EBR II

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Seok-Ju; Kang, Doo-Hyuk; Seo, Jae-Seung [System Engineering and Technology Co., Daejeon (Korea, Republic of); Bae, Sung-Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Jeong, Hae-Yong [Sejong University, Seoul (Korea, Republic of)

    2016-10-15

    In order to assess the uncertainty quantification of the MARS-LMR code, the code has been improved by modifying the source code to accommodate calculation process required for uncertainty quantification. In the present study, a transient of Unprotected Loss of Flow(ULOF) is selected as typical cases of as Anticipated Transient without Scram(ATWS) which belongs to DEC category. The MARS-LMR input generation for EBR II SHRT-45R and execution works are performed by using the PAPIRUS program. The sensitivity analysis is carried out with Uncertainty Parameter of the MARS-LMR code for EBR-II SHRT-45R. Based on the results of sensitivity analysis, dominant parameters with large sensitivity to FoM are picked out. Dominant parameters selected are closely related to the development process of ULOF event.

  17. Improved sample preparation and counting techniques for enhanced tritium measurement sensitivity

    Science.gov (United States)

    Moran, J.; Aalseth, C.; Bailey, V. L.; Mace, E. K.; Overman, C.; Seifert, A.; Wilcox Freeburg, E. D.

    2015-12-01

    Tritium (T) measurements offer insight to a wealth of environmental applications including hydrologic tracking, discerning ocean circulation patterns, and aging ice formations. However, the relatively short half-life of T (12.3 years) limits its effective age dating range. Compounding this limitation is the decrease in atmospheric T content by over two orders of magnitude (from 1000-2000 TU in 1962 to testing in the 1960's. We are developing sample preparation methods coupled to direct counting of T via ultra-low background proportional counters which, when combined, offer improved T measurement sensitivity (~4.5 mmoles of H2 equivalent) and will help expand the application of T age dating to smaller sample sizes linked to persistent environmental questions despite the limitations above. For instance, this approach can be used to T date ~ 2.2 mmoles of CH4 collected from sample-limited systems including microbial communities, soils, or subsurface aquifers and can be combined with radiocarbon dating to distinguish the methane's formation age from C age in a system. This approach can also expand investigations into soil organic C where the improved sensitivity will permit resolution of soil C into more descriptive fractions and provide direct assessments of the stability of specific classes of organic matter in soils environments. We are employing a multiple step sample preparation system whereby organic samples are first combusted with resulting CO2 and H2O being used as a feedstock to synthesize CH4. This CH4 is mixed with Ar and loaded directly into an ultra-low background proportional counter for measurement of T β decay in a shallow underground laboratory. Analysis of water samples requires only the addition of geologic CO2 feedstock with the sample for methane synthesis. The chemical nature of the preparation techniques enable high sample throughput with only the final measurement requiring T decay with total sample analysis time ranging from 2 -5 weeks

  18. The Mediterranean diet improves hepatic steatosis and insulin sensitivity in individuals with non-alcoholic fatty liver disease.

    Science.gov (United States)

    Ryan, Marno C; Itsiopoulos, Catherine; Thodis, Tania; Ward, Glenn; Trost, Nicholas; Hofferberth, Sophie; O'Dea, Kerin; Desmond, Paul V; Johnson, Nathan A; Wilson, Andrew M

    2013-07-01

    Non-alcoholic fatty liver disease (NAFLD) affects up to 30% of the population and signifies increased risk of liver fibrosis and cirrhosis, type 2 diabetes, and cardiovascular disease. Therapies are limited. Weight loss is of benefit but is difficult to maintain. We aimed at examining the effect of the Mediterranean diet (MD), a diet high in monounsaturated fatty acids, on steatosis and insulin sensitivity, using gold standard techniques. Twelve non-diabetic subjects (6 Females/6 Males) with biopsy-proven NAFLD were recruited for a randomised, cross-over 6-week dietary intervention study. All subjects undertook both the MD and a control diet, a low fat-high carbohydrate diet (LF/HCD), in random order with a 6-week wash-out period in- between. Insulin sensitivity was determined with a 3-h hyperinsulinemic-euglycemic clamp study and hepatic steatosis was assessed with localized magnetic resonance (1)H spectroscopy ((1)H-MRS). At baseline, subjects were abdominally obese with elevated fasting concentrations of glucose, insulin, triglycerides, ALT, and GGT. Insulin sensitivity at baseline was low (M=2.7 ± 1.0 mg/kg/min(-1)). Mean weight loss was not different between the two diets (p=0.22). There was a significant relative reduction in hepatic steatosis after the MD compared with the LF/HCD: 39 ± 4% versus 7 ± 3%, as measured by (1)H-MRS (p=0.012). Insulin sensitivity improved with the MD, whereas after the LF/HCD there was no change (p=0.03 between diets). Even without weight loss, MD reduces liver steatosis and improves insulin sensitivity in an insulin-resistant population with NAFLD, compared to current dietary advice. This diet should be further investigated in subjects with NAFLD. Copyright © 2013 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  19. Improved social force model based on exit selection for microscopic pedestrian simulation in subway station

    Institute of Scientific and Technical Information of China (English)

    郑勋; 李海鹰; 孟令云; 许心越; 陈旭

    2015-01-01

    An improved social force model based on exit selection is proposed to simulate pedestrians’ microscopic behaviors in subway station. The modification lies in considering three factors of spatial distance, occupant density and exit width. In addition, the problem of pedestrians selecting exit frequently is solved as follows: not changing to other exits in the affected area of one exit, using the probability of remaining preceding exit and invoking function of exit selection after several simulation steps. Pedestrians in subway station have some special characteristics, such as explicit destinations, different familiarities with subway station. Finally, Beijing Zoo Subway Station is taken as an example and the feasibility of the model results is verified through the comparison of the actual data and simulation data. The simulation results show that the improved model can depict the microscopic behaviors of pedestrians in subway station.

  20. Comparison of climate envelope models developed using expert-selected variables versus statistical selection

    Science.gov (United States)

    Brandt, Laura A.; Benscoter, Allison; Harvey, Rebecca G.; Speroterra, Carolina; Bucklin, David N.; Romañach, Stephanie; Watling, James I.; Mazzotti, Frank J.

    2017-01-01

    selection is a useful first step, especially when there is a need to model a large number of species or expert knowledge of the species is limited. Expert input can then be used to refine models that seem unrealistic or for species that experts believe are particularly sensitive to change. It also emphasizes the importance of using multiple models to reduce uncertainty and improve map outputs for conservation planning. Where outputs overlap or show the same direction of change there is greater certainty in the predictions. Areas of disagreement can be used for learning by asking why the models do not agree, and may highlight areas where additional on-the-ground data collection could improve the models.

  1. Sensitivity and fidelity of DNA microarray improved with integration of Amplified Differential Gene Expression (ADGE

    Directory of Open Access Journals (Sweden)

    Ile Kristina E

    2003-07-01

    Full Text Available Abstract Background The ADGE technique is a method designed to magnify the ratios of gene expression before detection. It improves the detection sensitivity to small change of gene expression and requires small amount of starting material. However, the throughput of ADGE is low. We integrated ADGE with DNA microarray (ADGE microarray and compared it with regular microarray. Results When ADGE was integrated with DNA microarray, a quantitative relationship of a power function between detected and input ratios was found. Because of ratio magnification, ADGE microarray was better able to detect small changes in gene expression in a drug resistant model cell line system. The PCR amplification of templates and efficient labeling reduced the requirement of starting material to as little as 125 ng of total RNA for one slide hybridization and enhanced the signal intensity. Integration of ratio magnification, template amplification and efficient labeling in ADGE microarray reduced artifacts in microarray data and improved detection fidelity. The results of ADGE microarray were less variable and more reproducible than those of regular microarray. A gene expression profile generated with ADGE microarray characterized the drug resistant phenotype, particularly with reference to glutathione, proliferation and kinase pathways. Conclusion ADGE microarray magnified the ratios of differential gene expression in a power function, improved the detection sensitivity and fidelity and reduced the requirement for starting material while maintaining high throughput. ADGE microarray generated a more informative expression pattern than regular microarray.

  2. Pick-and-place process for sensitivity improvement of the capacitive type CMOS MEMS 2-axis tilt sensor

    Science.gov (United States)

    Chang, Chun-I.; Tsai, Ming-Han; Liu, Yu-Chia; Sun, Chih-Ming; Fang, Weileun

    2013-09-01

    This study exploits the foundry available complimentary metal-oxide-semiconductor (CMOS) process and the packaging house available pick-and-place technology to implement a capacitive type micromachined 2-axis tilt sensor. The suspended micro mechanical structures such as the spring, stage and sensing electrodes are fabricated using the CMOS microelectromechanical systems (MEMS) processes. A bulk block is assembled onto the suspended stage by pick-and-place technology to increase the proof-mass of the tilt sensor. The low temperature UV-glue dispensing and curing processes are employed to bond the block onto the stage. Thus, the sensitivity of the CMOS MEMS capacitive type 2-axis tilt sensor is significantly improved. In application, this study successfully demonstrates the bonding of a bulk solder ball of 100 µm in diameter with a 2-axis tilt sensor fabricated using the standard TSMC 0.35 µm 2P4M CMOS process. Measurements show the sensitivities of the 2-axis tilt sensor are increased for 2.06-fold (x-axis) and 1.78-fold (y-axis) after adding the solder ball. Note that the sensitivity can be further improved by reducing the parasitic capacitance and the mismatch of sensing electrodes caused by the solder ball.

  3. Highly Selective and Sensitized Spectrophotometric Determination of Iron (3) Following Potentiometric Study

    International Nuclear Information System (INIS)

    Shokrollahi, A.; Ghaedi, M.; Rajabi, H.R.

    2007-01-01

    A simple, selective and sensitized spectrophotometric method for determination of trace amounts of Fe 3+ ion in tap and waste water solutions has been described. The spectrophotometric determination of Fe 3+ ion using Ferron in the presence of N,N-Dodecy trimethylammonium bromide (DTAB) has been carried out. The Beer's law is obeyed over the concentration range of 0.05-2.6 μg mL -1 of Fe 3+ ion with the relative standard deviation (RSD %) 3 L mol -1 cm -1 . Potentiometric pH titration has been used for prediction of protonation constants of ferron, and evaluating its stoichiometry and respective stability constant with Fe 3+ ion. As it is obvious the most likely species of ferron alone and its complexes are LH (log=7.64), LH 2 (logK=10.52), LH 3 (logK=11.74) and ML 2 (logβ= 23.68), ML 3 (logβ23.68), ML 3 H (logβ= 23.68), ML 3 H 2 (logβ= 23.68) and ML(OH) 2 (logβ=23.68) respectively

  4. Highly selective and sensitive detection of Cu2+ with lysine enhancing bovine serum albumin modified-carbon dots fluorescent probe.

    Science.gov (United States)

    Liu, Jia-Ming; Lin, Li-ping; Wang, Xin-Xing; Lin, Shao-Qin; Cai, Wen-Lian; Zhang, Li-Hong; Zheng, Zhi-Yong

    2012-06-07

    Based on the ability of lysine (Lys) to enhance the fluorescence intensity of bovine serum albumin modified-carbon dots (CDs-BSA) to decrease surface defects and quench fluorescence of the CDs-BSA-Lys system in the presence of Cu(2+) under conditions of phosphate buffer (PBS, pH = 5.0) at 45 °C for 10 min, a sensitive Lys enhancing CDs-BSA fluorescent probe was designed. The environment-friendly, simple, rapid, selective and sensitive fluorescent probe has been utilized to detect Cu(2+) in hair and tap water samples and it achieved consistent results with those obtained by inductively coupled plasma mass spectroscopy (ICP-MS). The mechanism of the proposed assay for the detection of Cu(2+) is discussed.

  5. Computer-aided detection of colorectal polyps: can it improve sensitivity of less-experienced readers? Preliminary findings.

    Science.gov (United States)

    Baker, Mark E; Bogoni, Luca; Obuchowski, Nancy A; Dass, Chandra; Kendzierski, Renee M; Remer, Erick M; Einstein, David M; Cathier, Pascal; Jerebko, Anna; Lakare, Sarang; Blum, Andrew; Caroline, Dina F; Macari, Michael

    2007-10-01

    To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polyps. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to re-evaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P=.0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review of CAD findings, the mean time was 3 minutes 38 seconds. Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers. Copyright (c) RSNA, 2007.

  6. Highly sensitive high resolution Raman spectroscopy using resonant ionization methods

    International Nuclear Information System (INIS)

    Owyoung, A.; Esherick, P.

    1984-05-01

    In recent years, the introduction of stimulated Raman methods has offered orders of magnitude improvement in spectral resolving power for gas phase Raman studies. Nevertheless, the inherent weakness of the Raman process suggests the need for significantly more sensitive techniques in Raman spectroscopy. In this we describe a new approach to this problem. Our new technique, which we call ionization-detected stimulated Raman spectroscopy (IDSRS), combines high-resolution SRS with highly-sensitive resonant laser ionization to achieve an increase in sensitivity of over three orders of magnitude. The excitation/detection process involves three sequential steps: (1) population of a vibrationally excited state via stimulated Raman pumping; (2) selective ionization of the vibrationally excited molecule with a tunable uv source; and (3) collection of the ionized species at biased electrodes where they are detected as current in an external circuit

  7. Filter Selection for Optimizing the Spectral Sensitivity of Broadband Multispectral Cameras Based on Maximum Linear Independence.

    Science.gov (United States)

    Li, Sui-Xian

    2018-05-07

    Previous research has shown that the effectiveness of selecting filter sets from among a large set of commercial broadband filters by a vector analysis method based on maximum linear independence (MLI). However, the traditional MLI approach is suboptimal due to the need to predefine the first filter of the selected filter set to be the maximum ℓ₂ norm among all available filters. An exhaustive imaging simulation with every single filter serving as the first filter is conducted to investigate the features of the most competent filter set. From the simulation, the characteristics of the most competent filter set are discovered. Besides minimization of the condition number, the geometric features of the best-performed filter set comprise a distinct transmittance peak along the wavelength axis of the first filter, a generally uniform distribution for the peaks of the filters and substantial overlaps of the transmittance curves of the adjacent filters. Therefore, the best-performed filter sets can be recognized intuitively by simple vector analysis and just a few experimental verifications. A practical two-step framework for selecting optimal filter set is recommended, which guarantees a significant enhancement of the performance of the systems. This work should be useful for optimizing the spectral sensitivity of broadband multispectral imaging sensors.

  8. Filter Selection for Optimizing the Spectral Sensitivity of Broadband Multispectral Cameras Based on Maximum Linear Independence

    Directory of Open Access Journals (Sweden)

    Sui-Xian Li

    2018-05-01

    Full Text Available Previous research has shown that the effectiveness of selecting filter sets from among a large set of commercial broadband filters by a vector analysis method based on maximum linear independence (MLI. However, the traditional MLI approach is suboptimal due to the need to predefine the first filter of the selected filter set to be the maximum ℓ2 norm among all available filters. An exhaustive imaging simulation with every single filter serving as the first filter is conducted to investigate the features of the most competent filter set. From the simulation, the characteristics of the most competent filter set are discovered. Besides minimization of the condition number, the geometric features of the best-performed filter set comprise a distinct transmittance peak along the wavelength axis of the first filter, a generally uniform distribution for the peaks of the filters and substantial overlaps of the transmittance curves of the adjacent filters. Therefore, the best-performed filter sets can be recognized intuitively by simple vector analysis and just a few experimental verifications. A practical two-step framework for selecting optimal filter set is recommended, which guarantees a significant enhancement of the performance of the systems. This work should be useful for optimizing the spectral sensitivity of broadband multispectral imaging sensors.

  9. Improving the precision of genotype selection in wheat performance trials

    Directory of Open Access Journals (Sweden)

    Giovani Benin

    2013-12-01

    Full Text Available The aim of this study was to verify whether using the Papadakis method improves model assumptions and experimental accuracy in field trials used to determine grain yield for wheat lineages indifferent Value for Cultivation and Use (VCU regions. Grain yield data from 572 field trials at 31 locations in the VCU Regions 1, 2, 3 and 4 in 2007-2011 were used. Each trial was run with and without the use of the Papadakis method. The Papadakis method improved the indices of experimental precision measures and reduced the number of experimental repetitions required to predict grain yield performance among the wheat genotypes. There were differences among the wheat adaptation regions in terms of the efficiency of the Papadakis method, the adjustment coefficient of the genotype averages and the increases in the selective accuracy of grain yield.

  10. Pioglitazone improves insulin sensitivity, reduces visceral fat and stimulates lipolysis in non diabetic dialyzed patients

    Directory of Open Access Journals (Sweden)

    Anne Zanchi

    2012-06-01

    Full Text Available Insulin resistance is common in dialyzed patients and is associated with increased mortality and protein-energy wasting. The aim of this study was to investigate the effect of pioglitazone (PIO, a powerful insulin sensitizer, on insulin sensitivity, body composition and adipose tissue metabolism, in dialyzed patients. A double blind randomized cross-over study was performed in non diabetic dialysis patients. Each patient followed 2 treatment phases of 16 weeks, starting either with oral PIO 45 mg/d or placebo (PL, and then switched to the other phase. At the end of each phase, patients underwent hyperinsulinemic euglycemic clamps, dual energy X-ray absorptiometry, an abdominal CT, and extensive plasma biochemical analysis. Twelve patients including 8 HD (59.6±4.4 y and 4 PD patients (43.5±3.6 y were recruited. Nine patients completed both phases and 3 patients dropped out (renal transplantation/2 HD and peritonitis/1 PD. PIO was safe and well tolerated. Under PIO, insulin sensitivity improved, as assessed by increased total glucose disposal rate (1.98±0.24 for PIO versus 1.58±0.12 umol/kg/min for PL, p<0.05, and reduced glucose endogenous hepatic production. PIO did not affect post-dialysis body weight, total fat and lean body mass, but significantly reduced visceral adipose tissue (VAT area and the VAT/SAT (subcutaneous adipose tissue ratio. HDL-cholesterol significantly increased. PIO decreased CRP (3.96±1.44 mg/l vs 7.88±2.56, p<0.05, plasma leptin, and dramatically reduced leptin/adiponectin ratio. Glycerol turnover, circulating glycerol and non esterified fatty acids were paradoxically increased. In conclusion, the improvement in insulin sensitivity by PIO, in non diabetic dialyzed patients, was associated with favorable metabolic effects, reduction in inflammation and body fat redistribution. The stimulation of systemic lipolysis was a surprising finding which may reflect adipose tissue remodeling and/or a paradoxical lypolitic

  11. Highly sensitive and selective room-temperature NO_2 gas sensor based on bilayer transferred chemical vapor deposited graphene

    International Nuclear Information System (INIS)

    Seekaew, Yotsarayuth; Phokharatkul, Ditsayut; Wisitsoraat, Anurat; Wongchoosuk, Chatchawal

    2017-01-01

    Highlights: • Simple and low-cost fabrication of bilayer graphene gas sensor was presented. • Layer effects of graphene on NO_2 gas-sensing properties were investigated. • Bilayer graphene sensor exhibited a high linear NO_2 sensitivity of 1.409 ppm"−"1. • The NO_2-sensing mechanisms based on band diagram were highlighted. - Abstract: This work presents a highly sensitive room-temperature gas sensor based on bilayer graphene fabricated by an interfacial transfer of chemical vapor deposited graphene onto nickel interdigitated electrodes. Scanning electron microscopic and Raman spectroscopic characterizations confirm the presence of graphene on interdigitated nickel electrodes with varying numbers of graphene layers. The NO_2 detection performances of bilayer graphene gas sensor have been investigated in comparison with those of monolayer and multilayer graphene gas sensors at room temperature. From results, the bilayer graphene gas sensor exhibits higher response, sensitivity and selectivity to NO_2 than monolayer and multilayer graphene. The sensitivity of bilayer graphene gas sensor is 1.409 ppm"−"1 towards NO_2 over a concentration range of 1–25 ppm, which is more than twice higher than that of monolayer graphene. The NO_2-sensing mechanism of graphene sensing film has been explained based on the direct charge transfer process due to the adsorption of NO_2 molecules.

  12. Highly sensitive and selective determination of methylergometrine maleate using carbon nanofibers/silver nanoparticles composite modified carbon paste electrode

    International Nuclear Information System (INIS)

    Kalambate, Pramod K.; Rawool, Chaitali R.; Karna, Shashi P.; Srivastava, Ashwini K.

    2016-01-01

    A highly sensitive and selective voltammetric method for determination of Methylergometrine maleate (MM) in pharmaceutical formulations, urine and blood serum samples has been developed based on enhanced electrochemical response of MM at carbon nanofibers and silver nanoparticles modified carbon paste electrode (CNF-AgNP-CPE). The electrode material was characterized by various techniques viz., X-ray diffraction, scanning electron microscopy and energy dispersive X-ray spectroscopy. The electrocatalytic response of MM at CNF-AgNP-CPE was studied by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Under optimized conditions, the proposed sensor exhibits excellent electrochemical response towards MM. The DPV study shows greatly enhanced electrochemical signal for MM at CNF-AgNP-CPE lending high sensitivity to the proposed sensor for MM detection. The peak (I p ) current for MM is found to be rectilinear in the range 4.0 × 10 −8 –2.0 × 10 −5 M with a detection limit of 7.1 × 10 −9 M using DPV. The feasibility of the proposed sensor in analytical applications was investigated by conducting experiments on commercial pharmaceutical formulations, human urine and blood serum samples, which yielded satisfactory recoveries of MM. The proposed electrochemical sensor offers high sensitivity, selectivity, reproducibility and practical utility. We recommend it as an authentic and productive electrochemical sensor for successful determination of MM. - Highlights: • Voltammetric sensor for methylergometrine maleate using carbon nanofibers and silver nanoparticle - carbon paste electrode • Wide working range, good reproducibility, fast response and high stability were the main advantages of the proposed sensor • Analysis of methylergometrine maleate in pharmaceutical formulations, urine and blood serum samples • Lowest limit of detection obtained for methylergometrine maleate

  13. Improved Selectivity From a Wavelength Addressable Device for Wireless Stimulation of Neural Tissue

    Directory of Open Access Journals (Sweden)

    Elif Ç. Seymour

    2014-02-01

    Full Text Available Electrical neural stimulation with micro electrodes is a promising technique for restoring lost functions in the central nervous system as a result of injury or disease. One of the problems related to current neural stimulators is the tissue response due to the connecting wires and the presence of a rigid electrode inside soft neural tissue. We have developed a novel, optically activated, microscale photovoltaic neurostimulator based on a custom layered compound semiconductor heterostructure that is both wireless and has a comparatively small volume. Optical activation provides a wireless means of energy transfer to the neurostimulator, eliminating wires and the associated complications. This neurostimulator was shown to evoke action potentials and a functional motor response in the rat spinal cord. In this work, we extend our design to include wavelength selectivity and thus allowing independent activation of devices. As a proof of concept, we fabricated two different microscale devices with different spectral responsivities in the near-infrared region. We assessed the improved addressability of individual devices via wavelength selectivity as compared to spatial selectivity alone through on-bench optical measurements of the devices in combination with an in vivo light intensity profile in the rat cortex obtained in a previous study. We show that wavelength selectivity improves the individual addressability of the floating stimulators, thus increasing the number of devices that can be implanted in close proximity to each other.

  14. Over-expression of Follistatin-like 3 attenuates fat accumulation and improves insulin sensitivity in mice

    DEFF Research Database (Denmark)

    Brandt, Claus; Hansen, Rasmus Hvass; Hansen, Jakob Bondo

    2015-01-01

    -fat feeding. Body weight, food intake, fat accumulation by MR scanning, and glucose, insulin and glucagon tolerance were evaluated, as was the response in body weight and metabolic parameters to 24h fasting. Effects of fstl3 on pancreatic insulin and glucagon content, and pancreatic islet morphology were......OBJECTIVE: Follistatin-like 3 (fstl3), a natural inhibitor of members of the TGF-β family, increases during resistance training in human plasma. Fstl3 primarily binds myostatin and activin A, and thereby inhibits their functions. We hypothesize that blocking myostatin and activin A signalling....../glucagon ratio. Accordingly, fstl3 transfection improved counter-regulation to 24h fasting. CONCLUSION: Fstl3 over-expression regulates insulin and glucagon sensitivities through increased muscular insulin action, as well as increased hepatic glucagon sensitivity and pancreatic glucagon content....

  15. A panchromatic anthracene-fused porphyrin sensitizer for dye-sensitized solar cells

    KAUST Repository

    Ball, James M.; Davis, Nicola K. S.; Wilkinson, James D.; Kirkpatrick, James; Teuscher, Joë l; Gunning, Robert; Anderson, Harry L.; Snaith, Henry J.

    2012-01-01

    The development of ruthenium-free sensitizers which absorb light over a broad range of the solar spectrum is important for improving the power conversion efficiency of dye-sensitized solar cells. Here we study three chemically tailored porphyrin

  16. Sensitivity of CERES-Maize yield simulation to the selected weather data

    International Nuclear Information System (INIS)

    Zalud, Z.; Stastna, M.

    2000-01-01

    Sensitivity analysis of selected weather data runs after successful parametrization and validation of the CERES-Maize simulation model. Estimation of the potential yield has been carried out during the long term experiment (1980-1997) as well as the estimation of influence of meteorological parameters on the simulation results for the water-limited yield. 10 % under and over stimulation of global radiation and precipitation as well as increasing and decreasing temperature by 1 deg C on simulated potential and water-limited yield have been done. In most of the years, air temperature underestimation resulted in a higher simulated grain yield and overstimulation shown a lower yield for water limited level. Overestimation of precipitation during wet days in growing period of the maize leads to an increase of amount of water available for the plant and to increase the yield. Underestimation of global radiation by 10 % resulted in a decline in simulated grain yield from -8.8 to -9.9 %. The overestimation caused increase of the yield from 7.8 to 10 %. Overestimation by 10 % resulted in a slight underestimation of the yield in low yielding years and underestimation of global radiation by 10 % in overestimation of the yield. The effect was opposite in high yielding years

  17. Genetic tests in work place from the preventive selection to selective prevention

    International Nuclear Information System (INIS)

    Poissonnet, C.M.; Veron, M.

    2004-01-01

    The research in this area allows to better understand the mechanisms of illness trigger, to improve the knowledge in the relation exposure-illness, to detect the risk associated to low exposure among some particularly sensitive persons and to define the validity criteria. Inevitably these researches reach to define the most vulnerable persons. This designation could be a factor favorable to the prevention and to give a better sense of responsibility. The worker, well informed, can be particularly concerned by wearing the individual protections, and the person in charge of the installation by looking to reduce exposure. It can be also deviate and corresponds to a real discrimination with rejection of sensitive persons and selection of resistant individuals with which it could be possible to work in non optimal conditions. The problem is at this level the conflicts of interest exist between these ones that dream to use this possibility wisely and that ones for which the interests are elsewhere. (N.C.)

  18. Highly selective and sensitive coumarin-triazole-based fluorometric 'turn-off' sensor for detection of Pb2+ ions.

    Science.gov (United States)

    Shaily; Kumar, Ajay; Parveen, Iram; Ahmed, Naseem

    2018-06-01

    Exposure to even very low concentrations of Pb 2+ is known to cause cardiovascular, neurological, developmental, and reproductive disorders, and affects children in particular more severely. Consequently, much effort has been dedicated to the development of colorimetric and fluorescent sensors that can selectively detect Pb 2+ ions. Here, we describe the development of a triazole-based fluorescent sensor L5 for Pb 2+ ion detection. The fluorescence intensity of chemosensor L5 was selectively quenched by Pb 2+ ions and a clear color change from colorless to yellow could be observed by the naked eye. Chemosensor L5 exhibited high sensitivity and selectivity towards Pb 2+ ions in phosphate-buffered solution [20 mM, 1:9 DMSO/H 2 O (v/v), pH 8.0] with a 1:1 binding stoichiometry, a detection limit of 1.9 nM and a 6.76 × 10 6  M -1 binding constant. Additionally, low-cost and easy-to-prepare test strips impregnated with chemosensor L5 were also produced for efficient of Pb 2+ detection and proved the practical use of this test. Copyright © 2018 John Wiley & Sons, Ltd.

  19. A composite material based on nanoparticles of yttrium (III) oxide for the selective and sensitive electrochemical determination of acetaminophen

    International Nuclear Information System (INIS)

    Baytak, Aysegul Kutluay; Teker, Tugce; Duzmen, Sehriban; Aslanoglu, Mehmet

    2016-01-01

    An electrochemical sensor was prepared by modifying a glassy carbon electrode (GCE) with a composite of yttrium (III) oxide nanoparticles (Y_2O_3NPs) and carbon nanotubes (CNTs) for the determination of acetaminophen (ACT). Compared with a bare GCE and CNTs/GCE, the Y_2O_3NPs/CNTs/GCE exhibited a well-defined redox couple for ACT and highly enhanced the current response. The separations in the anodic and cathodic peak potentials (ΔE_p) for ACT were 552 mV, 24 mV and 10 mV at ba4re GCE, CNTs/GCE and Y_2O_3NPs/CNTs/GCE, respectively. The observation of only 10 mV of ΔE_p for ACT at Y_2O_3NPs/CNTs/GCE was a clear indication of a great acceleration of the electrode process compared to bare GCE and GCE modified with CNTs. Also, L-ascorbic acid (L-AA) and L-tyrosine (L-TRY) did not interfere with the selective determination of ACT. Square wave voltammetry (SWV) was performed for the quantification of ACT. A linear plot was obtained for current responses versus the concentrations of ACT over the range from 1.0 × 10"−"1"0 to 1.8 × 10"−"8 M with a detection limit of 3.0 × 10"−"1"1 M (based on 3S_b/m). The proposed composite material provided high electrocatalytic activity, improved voltammetric behavior, good selectivity and good reproducibility. The accurate quantification of ACT makes the proposed electrode of great interest for the public health. - Highlights: • A voltammetric sensor based on yttrium oxide was prepared for the detection of ACT. • The proposed electrode has greatly accelerated the voltammetric process of ACT. • A detection limit of 0.03 nM was obtained for ACT. • The proposed electrode exhibited great selectivity for ACT in the presence of L-AA and L-TRY. • The composite material exhibited high sensitivity, good stability and excellent reproducibility.

  20. A highly sensitive, single selective, fluorescent sensor for Al{sup 3+} detection and its application in living cell imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Xing-Pei [Department of Physics and Chemistry, Henan Polytechnic University, Jiaozuo 454000 (China); Sun, Shao-bo; Li, Ying-dong [Institute of Integrated Traditional and Western Medicine, Gansu University of Traditional Chinese Medicine, Lanzhou 730000 (China); Zhi, Li-hua [Department of Physics and Chemistry, Henan Polytechnic University, Jiaozuo 454000 (China); Wu, Wei-na, E-mail: wuwn08@hpu.edu.cn [Department of Physics and Chemistry, Henan Polytechnic University, Jiaozuo 454000 (China); Wang, Yuan, E-mail: wangyuan08@hpu.edu.cn [Department of Physics and Chemistry, Henan Polytechnic University, Jiaozuo 454000 (China)

    2014-11-15

    A new o-aminophenol-based fluorogenic chemosensor methyl 3,5-bis((E)-(2-hydroxyphenylimino)methyl)-4-hydroxybenzoate 1 have been synthesized by Schiff base condensation of methyl 3,5-diformyl-4-hydroxybenzoate with o-aminophenol, which exhibits high selectivity and sensitivity toward Al{sup 3+}. Fluorescence titration studies of receptors 1 with different metal cations in CH{sub 3}OH medium showed highly selective and sensitive towards Al{sup 3+} ions even in the presence of other commonly coexisting metal ions. The detection limit of Al{sup 3+} ions is at the parts per billion level. Interestingly, the Al(III) complex of 1 offered a large Stokes shift (>120 nm), which can miximize the selfquenching effect. In addition, possible utilization of this receptor as bio-imaging fluorescent probe to detect Al{sup 3+} in human cervical HeLa cancer cell lines was also investigated by confocal fluorescence microscopy. - Highlights: • A new Schiff base chemosensor is reported. • The sensor for Al{sup 3+} offers large Stokes shift. • The detection limit of Al{sup 3+} in CH{sub 3}OH solution is at the parts per billion level. • The utilization of sensor for the monitoring of Al{sup 3+} levels in living cells was examined.

  1. Selective and sensitive fluorescence-shift probes based on two dansyl groups for mercury(ii) ion detection.

    Science.gov (United States)

    Ma, Li-Jun; Liu, Jialun; Deng, Lefang; Zhao, Meili; Deng, Zhifu; Li, Xutian; Tang, Jian; Yang, Liting

    2014-11-01

    Two probes ( and ) bearing two dansyl fluorophores were synthesized and applied to the detection of mercury(ii) ions in aqueous solution. These probes exhibited a selective response to Hg(2+) in a buffered solution, with high sensitivity and a unique fluorescence response signal which displayed a blue-shift effect in the fluorescence emission peak. The Hg(2+) recognition mechanisms of the probes were determined by NMR spectroscopy, ESI-MS and UV-vis spectroscopy. The results showed that probe and mercury(ii) ions formed an unusual 2:2 stoichiometric ratio complex, while probe and Hg(2+) formed a multidentate complex with a stoichiometric ratio of 2:1.

  2. Cannabinoid 2 Receptor Agonist Improves Systemic Sensitivity to Insulin in High-Fat Diet/Streptozotocin-Induced Diabetic Mice

    Directory of Open Access Journals (Sweden)

    Xiuyuan Zhang

    2016-12-01

    Full Text Available Background/Aims: The endocannabinoid signalling (ECS system has been known to regulate glucose homeostasis. Previous studies have suggested that the cannabinoid 2 (CB2 receptor may play a regulatory role on insulin secretion, immune modulation and insulin resistance. Given that diabetes and insulin resistance are attributable to elevated inflammatory tone, we investigated the role of CB2 receptor on glucose tolerance and insulin sensitivity in high-fat diet (HFD/streptozotocin (STZ-induced mice. Methods: Diabetes was induced in male ICR mice by HFD/STZ and exposed to a CB2 receptor agonist, SER601, for 2- or 4-weeks via subcutaneous implantation of osmotic minipumps. Glucose and insulin tolerance tests were performed at the end of treatment. Islets were isolated for assessment of β-cell function. Pancreases and skeletal muscles were also obtained for histological analyses. Results: Despite a lack of impact on glucose tolerance, substantial improvement on insulin sensitivity was observed in SER601-treated mice, which could partly be attributed to improved islet β-cell function, shown as increased glucose-induced insulin secretion and insulin content. No changes on islet macrophage infiltration or skeletal muscle fat deposition were detectable from SER601-treated mice. However, a major decrease in body weight was recorded at the end of 4-week SER601 exposure, accompanied by a lack of epididymal adipose mass in SER601-treated mice. Conclusion: Our data suggest a lipolytic role of SER601 in HFD/STZ-induced diabetic mice, which results in significant improvement of systemic insulin sensitivity. Thus, the CB2 receptor may be considered a promising target for therapeutic development against insulin resistance and obesity-related diabetes.

  3. Improvement of Insulin Sensitivity after Lean Donor Feces in Metabolic Syndrome Is Driven by Baseline Intestinal Microbiota Composition

    DEFF Research Database (Denmark)

    Kootte, Ruud S.; Levin, Evgeni; Salojärvi, Jarkko

    2017-01-01

    be predicted based on baseline fecal microbiota composition. Kootte et al. show that fecal microbiota transplantation from lean donors to obese patients with metabolic syndrome improves insulin sensitivity, a transient effect associated with changes in microbiota composition and fasting plasma metabolites...

  4. Consequences of implementing a cardiac troponin assay with improved sensitivity at Swedish coronary care units: an analysis from the SWEDEHEART registry.

    Science.gov (United States)

    Eggers, Kai M; Lindahl, Bertil; Melki, Dina; Jernberg, Tomas

    2016-08-07

    Cardiac troponin (cTn) assays with improved sensitivity are increasingly utilized for the assessment of patients admitted because of suspected acute coronary syndrome (ACS). However, data on the clinical consequences of the implementation of such assays are limited. In a retrospective register-based study (37 710 coronary care unit admissions; SWEDEHEART registry), we compared the case mix, the use of diagnostic procedures, treatments, and 1-year all-cause mortality 1 year before the implementation of a cTn assay with improved sensitivity (study period 1) and 1 year thereafter (study period 2). During study period 2, more at-risk patients were admitted and more patients had cTn levels above the myocardial infarction cut-off (ACS patients +13.1%; non-ACS patients +160.1%). cTn levels above this cut-off exhibited stronger associations with mortality risk in study period 2 (adjusted HR 4.45 [95% confidence interval, CI, 3.36-5.89]) compared with period 1 (adjusted HR 2.43 [95% CI 2.11-2.80]), similar as for the cTn ratio relative to the respective 99th percentile. While there was no multivariable-adjusted increase in the use of diagnostic procedures, significant trends towards more differentiated treatment depending on the cause of cTn elevation, i.e. ACS or non-ACS, were noted. The implementation of a cTn assay with improved sensitivity was associated with an increase in the number of patients who due to their cTn-status were identified as suitable for beneficial therapies. There was no inappropriate increase in hospital resource utilization. As such, cTn assays with improved sensitivity provide an opportunity to improve the clinical management of patients with suspected ACS. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  5. Enhancement of NH3 gas sensitivity at room temperature by carbon nanotube-based sensor coated with Co nanoparticles.

    Science.gov (United States)

    Nguyen, Lich Quang; Phan, Pho Quoc; Duong, Huyen Ngoc; Nguyen, Chien Duc; Nguyen, Lam Huu

    2013-01-30

    Multi-walled carbon nanotube (MWCNT) film has been fabricated onto Pt-patterned alumina substrates using the chemical vapor deposition method for NH(3) gas sensing applications. The MWCNT-based sensor is sensitive to NH(3) gas at room temperature. Nanoclusters of Co catalysts have been sputtered on the surface of the MWCNT film to enhance gas sensitivity with respect to unfunctionalized CNT films. The gas sensitivity of Co-functionalized MWCNT-based gas sensors is thus significantly improved. The sensor exhibits good repeatability and high selectivity towards NH(3), compared with alcohol and LPG.

  6. Action video game playing is associated with improved visual sensitivity, but not alterations in visual sensory memory.

    Science.gov (United States)

    Appelbaum, L Gregory; Cain, Matthew S; Darling, Elise F; Mitroff, Stephen R

    2013-08-01

    Action video game playing has been experimentally linked to a number of perceptual and cognitive improvements. These benefits are captured through a wide range of psychometric tasks and have led to the proposition that action video game experience may promote the ability to extract statistical evidence from sensory stimuli. Such an advantage could arise from a number of possible mechanisms: improvements in visual sensitivity, enhancements in the capacity or duration for which information is retained in visual memory, or higher-level strategic use of information for decision making. The present study measured the capacity and time course of visual sensory memory using a partial report performance task as a means to distinguish between these three possible mechanisms. Sensitivity measures and parameter estimates that describe sensory memory capacity and the rate of memory decay were compared between individuals who reported high evels and low levels of action video game experience. Our results revealed a uniform increase in partial report accuracy at all stimulus-to-cue delays for action video game players but no difference in the rate or time course of the memory decay. The present findings suggest that action video game playing may be related to enhancements in the initial sensitivity to visual stimuli, but not to a greater retention of information in iconic memory buffers.

  7. Simultaneous improvement of grain yield and protein content in durum wheat by different phenotypic indices and genomic selection.

    Science.gov (United States)

    Rapp, M; Lein, V; Lacoudre, F; Lafferty, J; Müller, E; Vida, G; Bozhanova, V; Ibraliu, A; Thorwarth, P; Piepho, H P; Leiser, W L; Würschum, T; Longin, C F H

    2018-06-01

    Simultaneous improvement of protein content and grain yield by index selection is possible but its efficiency largely depends on the weighting of the single traits. The genetic architecture of these indices is similar to that of the primary traits. Grain yield and protein content are of major importance in durum wheat breeding, but their negative correlation has hampered their simultaneous improvement. To account for this in wheat breeding, the grain protein deviation (GPD) and the protein yield were proposed as targets for selection. The aim of this work was to investigate the potential of different indices to simultaneously improve grain yield and protein content in durum wheat and to evaluate their genetic architecture towards genomics-assisted breeding. To this end, we investigated two different durum wheat panels comprising 159 and 189 genotypes, which were tested in multiple field locations across Europe and genotyped by a genotyping-by-sequencing approach. The phenotypic analyses revealed significant genetic variances for all traits and heritabilities of the phenotypic indices that were in a similar range as those of grain yield and protein content. The GPD showed a high and positive correlation with protein content, whereas protein yield was highly and positively correlated with grain yield. Thus, selecting for a high GPD would mainly increase the protein content whereas a selection based on protein yield would mainly improve grain yield, but a combination of both indices allows to balance this selection. The genome-wide association mapping revealed a complex genetic architecture for all traits with most QTL having small effects and being detected only in one germplasm set, thus limiting the potential of marker-assisted selection for trait improvement. By contrast, genome-wide prediction appeared promising but its performance strongly depends on the relatedness between training and prediction sets.

  8. Improvements to the hierarchically structured ZnO nanosphere based dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yongzhe; Wu Lihui; Liu Yanping; Xie Erqing, E-mail: zhangyzh04@126.co, E-mail: xieeq@lzu.edu.c [School of Physical Science and Technology, Lanzhou University, Lanzhou 730000 (China)

    2009-04-21

    Hierarchically structured ZnO nanospheres are synthesized by a wet-chemical method and ZnO sphere-consisting films are applied to dye-sensitized solar cells (DSSCs). It is found that the overall light-to-electricity conversion efficiency ({eta}) is significantly enhanced from 0.474% to 1.03% due to light scattering compared with the ZnO nanoparticle-based DSSC. However, the fill factor (FF) and open-circuit voltage (V{sub oc}) decrease obviously. After annealing the films in an oxygen environment and placing a ZnO blocking layer on the fluorine-doped SnO{sub 2} (FTO) conducting substrate, the FF and V{sub oc} are greatly improved and {eta} increases from 1.03% to 1.59% and 2.25%, respectively. According to the results of x-ray diffraction and photoluminescence, the significant improvements in the cell performances might be due to the suppression of the recombination and the decrease in the resistances existing in the cell.

  9. Clustering and training set selection methods for improving the accuracy of quantitative laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Anderson, Ryan B.; Bell, James F.; Wiens, Roger C.; Morris, Richard V.; Clegg, Samuel M.

    2012-01-01

    We investigated five clustering and training set selection methods to improve the accuracy of quantitative chemical analysis of geologic samples by laser induced breakdown spectroscopy (LIBS) using partial least squares (PLS) regression. The LIBS spectra were previously acquired for 195 rock slabs and 31 pressed powder geostandards under 7 Torr CO 2 at a stand-off distance of 7 m at 17 mJ per pulse to simulate the operational conditions of the ChemCam LIBS instrument on the Mars Science Laboratory Curiosity rover. The clustering and training set selection methods, which do not require prior knowledge of the chemical composition of the test-set samples, are based on grouping similar spectra and selecting appropriate training spectra for the partial least squares (PLS2) model. These methods were: (1) hierarchical clustering of the full set of training spectra and selection of a subset for use in training; (2) k-means clustering of all spectra and generation of PLS2 models based on the training samples within each cluster; (3) iterative use of PLS2 to predict sample composition and k-means clustering of the predicted compositions to subdivide the groups of spectra; (4) soft independent modeling of class analogy (SIMCA) classification of spectra, and generation of PLS2 models based on the training samples within each class; (5) use of Bayesian information criteria (BIC) to determine an optimal number of clusters and generation of PLS2 models based on the training samples within each cluster. The iterative method and the k-means method using 5 clusters showed the best performance, improving the absolute quadrature root mean squared error (RMSE) by ∼ 3 wt.%. The statistical significance of these improvements was ∼ 85%. Our results show that although clustering methods can modestly improve results, a large and diverse training set is the most reliable way to improve the accuracy of quantitative LIBS. In particular, additional sulfate standards and specifically

  10. Polymeric optical sensors for selective and sensitive nitrite detection using cobalt(III) corrole and rhodium(III) porphyrin as ionophores

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Si; Wo, Yaqi; Meyerhoff, Mark E., E-mail: mmeyerho@umich.edu

    2014-09-16

    Highlights: • We examine cobalt(III) corroles and rhodium(III) porphyrins as ionophores in polymeric films for optical sensors to detect nitrite. • Different types of proton chromoionophores are evaluated to optimize nitrite response. • Selectivity over lipophilic anions such as perchlorate and thiocyanate is observed. • Both ionophores yield optical sensors that are fully reversible. • The cobalt(III) corrole based sensor is employed to determine nitric oxide emission rates from NO donor doped polymers with good accuracy. - Abstract: Cobalt(III) 5,10,15-tris(4-tert-butylphenyl) corrole with a triphenylphosphine axial ligand and rhodium(III) 5,10,15,20-tetra(p-tert-butylphenyl) porphyrin are incorporated into plasticized poly(vinyl chloride) films to fabricate nitrite-selective bulk optodes via absorbance measurements. The resulting films yield sensitive, fast and fully reversible response toward nitrite with significantly enhanced nitrite selectivity over other anions including lipophilic anions such as thiocyanate and perchlorate. The selectivity patterns differ greatly from the Hofmeister series based on anion lipophilicity and are consistent with selectivity obtained with potentiometric sensors based on the same ionophores. The optical nitrite sensors are shown to be useful for detecting rates of emission of nitric oxide (NO) from NO releasing polymers containing S-nitroso-N-acetyl-DL-penicillamine.

  11. Training directionally selective motion pathways can significantly improve reading efficiency

    Science.gov (United States)

    Lawton, Teri

    2004-06-01

    This study examined whether perceptual learning at early levels of visual processing would facilitate learning at higher levels of processing. This was examined by determining whether training the motion pathways by practicing leftright movement discrimination, as found previously, would improve the reading skills of inefficient readers significantly more than another computer game, a word discrimination game, or the reading program offered by the school. This controlled validation study found that practicing left-right movement discrimination 5-10 minutes twice a week (rapidly) for 15 weeks doubled reading fluency, and significantly improved all reading skills by more than one grade level, whereas inefficient readers in the control groups barely improved on these reading skills. In contrast to previous studies of perceptual learning, these experiments show that perceptual learning of direction discrimination significantly improved reading skills determined at higher levels of cognitive processing, thereby being generalized to a new task. The deficits in reading performance and attentional focus experienced by the person who struggles when reading are suggested to result from an information overload, resulting from timing deficits in the direction-selectivity network proposed by Russell De Valois et al. (2000), that following practice on direction discrimination goes away. This study found that practicing direction discrimination rapidly transitions the inefficient 7-year-old reader to an efficient reader.

  12. Improving the baking quality of bread wheat by genomic selection in early generations.

    Science.gov (United States)

    Michel, Sebastian; Kummer, Christian; Gallee, Martin; Hellinger, Jakob; Ametz, Christian; Akgöl, Batuhan; Epure, Doru; Löschenberger, Franziska; Buerstmayr, Hermann

    2018-02-01

    Genomic selection shows great promise for pre-selecting lines with superior bread baking quality in early generations, 3 years ahead of labour-intensive, time-consuming, and costly quality analysis. The genetic improvement of baking quality is one of the grand challenges in wheat breeding as the assessment of the associated traits often involves time-consuming, labour-intensive, and costly testing forcing breeders to postpone sophisticated quality tests to the very last phases of variety development. The prospect of genomic selection for complex traits like grain yield has been shown in numerous studies, and might thus be also an interesting method to select for baking quality traits. Hence, we focused in this study on the accuracy of genomic selection for laborious and expensive to phenotype quality traits as well as its selection response in comparison with phenotypic selection. More than 400 genotyped wheat lines were, therefore, phenotyped for protein content, dough viscoelastic and mixing properties related to baking quality in multi-environment trials 2009-2016. The average prediction accuracy across three independent validation populations was r = 0.39 and could be increased to r = 0.47 by modelling major QTL as fixed effects as well as employing multi-trait prediction models, which resulted in an acceptable prediction accuracy for all dough rheological traits (r = 0.38-0.63). Genomic selection can furthermore be applied 2-3 years earlier than direct phenotypic selection, and the estimated selection response was nearly twice as high in comparison with indirect selection by protein content for baking quality related traits. This considerable advantage of genomic selection could accordingly support breeders in their selection decisions and aid in efficiently combining superior baking quality with grain yield in newly developed wheat varieties.

  13. A sensitive molecularly imprinted polymer based quartz crystal microbalance nanosensor for selective determination of lovastatin in red yeast rice.

    Science.gov (United States)

    Eren, Tanju; Atar, Necip; Yola, Mehmet Lütfi; Karimi-Maleh, Hassan

    2015-10-15

    Lovastatin (LOV) is a statin, used to lower cholesterol which has been found as a hypolipidemic agent in commercial red yeast rice. In present study, a sensitive molecular imprinted quartz crystal microbalance (QCM) sensor was prepared by fabricating a self-assembling monolayer formation of allylmercaptane on QCM chip surface for selective determination of lovastatin (LOV) in red yeast rice. To prepare molecular imprinted quartz crystal microbalance (QCM) nanosensor, LOV imprinted poly(2-hydroxyethyl methacrylate-methacryloylamidoaspartic acid) [p(HEMA-MAAsp)] nanofilm was attached on the modified gold surface of QCM chip. The non-modified and improved surfaces were characterized by using contact angle, atomic force microscopy (AFM) and Fourier transform infrared (FTIR) spectroscopy. The imprinted QCM sensor was validated according to the ICH guideline (International Conference on Harmonisation). The linearity range was obtained as 0.10-1.25 nM. The detection limit of the prepared material was calculated as 0.030 nM. The developed QCM nanosensor was successfully used to examine red yeast rice. Furthermore, the stability and repeatability of the prepared QCM nanosensor were studied. The spectacular long-term stability and repeatability of the prepared LOV-imprinted QCM nanosensor make them intriguing for use in QCM sensors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Generalized structural equations improve sexual-selection analyses.

    Directory of Open Access Journals (Sweden)

    Sonia Lombardi

    Full Text Available Sexual selection is an intense evolutionary force, which operates through competition for the access to breeding resources. There are many cases where male copulatory success is highly asymmetric, and few males are able to sire most females. Two main hypotheses were proposed to explain this asymmetry: "female choice" and "male dominance". The literature reports contrasting results. This variability may reflect actual differences among studied populations, but it may also be generated by methodological differences and statistical shortcomings in data analysis. A review of the statistical methods used so far in lek studies, shows a prevalence of Linear Models (LM and Generalized Linear Models (GLM which may be affected by problems in inferring cause-effect relationships; multi-collinearity among explanatory variables and erroneous handling of non-normal and non-continuous distributions of the response variable. In lek breeding, selective pressure is maximal, because large numbers of males and females congregate in small arenas. We used a dataset on lekking fallow deer (Dama dama, to contrast the methods and procedures employed so far, and we propose a novel approach based on Generalized Structural Equations Models (GSEMs. GSEMs combine the power and flexibility of both SEM and GLM in a unified modeling framework. We showed that LMs fail to identify several important predictors of male copulatory success and yields very imprecise parameter estimates. Minor variations in data transformation yield wide changes in results and the method appears unreliable. GLMs improved the analysis, but GSEMs provided better results, because the use of latent variables decreases the impact of measurement errors. Using GSEMs, we were able to test contrasting hypotheses and calculate both direct and indirect effects, and we reached a high precision of the estimates, which implies a high predictive ability. In synthesis, we recommend the use of GSEMs in studies on

  15. Improving Breeding Selection of Seed Quality Traits for Food-Grade Soybeans

    OpenAIRE

    Escamilla Sanchez, Diana Marcela

    2018-01-01

    Natto and sprout soybeans are produced using small-seeded soybeans and their production is a high value alternative to grow grain soybeans for food in U.S. The development of soybean cultivars with improved natto and sprout quality is crucial for maintaining and increasing the soyfood market. However, there is insufficient information on sprout soybean characteristics. Therefore, the first objective of this study was to evaluate seed and sprout traits as potential selection criteria and study...

  16. Improving permafrost distribution modelling using feature selection algorithms

    Science.gov (United States)

    Deluigi, Nicola; Lambiel, Christophe; Kanevski, Mikhail

    2016-04-01

    The availability of an increasing number of spatial data on the occurrence of mountain permafrost allows the employment of machine learning (ML) classification algorithms for modelling the distribution of the phenomenon. One of the major problems when dealing with high-dimensional dataset is the number of input features (variables) involved. Application of ML classification algorithms to this large number of variables leads to the risk of overfitting, with the consequence of a poor generalization/prediction. For this reason, applying feature selection (FS) techniques helps simplifying the amount of factors required and improves the knowledge on adopted features and their relation with the studied phenomenon. Moreover, taking away irrelevant or redundant variables from the dataset effectively improves the quality of the ML prediction. This research deals with a comparative analysis of permafrost distribution models supported by FS variable importance assessment. The input dataset (dimension = 20-25, 10 m spatial resolution) was constructed using landcover maps, climate data and DEM derived variables (altitude, aspect, slope, terrain curvature, solar radiation, etc.). It was completed with permafrost evidences (geophysical and thermal data and rock glacier inventories) that serve as training permafrost data. Used FS algorithms informed about variables that appeared less statistically important for permafrost presence/absence. Three different algorithms were compared: Information Gain (IG), Correlation-based Feature Selection (CFS) and Random Forest (RF). IG is a filter technique that evaluates the worth of a predictor by measuring the information gain with respect to the permafrost presence/absence. Conversely, CFS is a wrapper technique that evaluates the worth of a subset of predictors by considering the individual predictive ability of each variable along with the degree of redundancy between them. Finally, RF is a ML algorithm that performs FS as part of its

  17. Short-Term Exercise Training Improves Insulin Sensitivity but Does Not Inhibit Inflammatory Pathways in Immune Cells from Insulin-Resistant Subjects

    Directory of Open Access Journals (Sweden)

    Sara M. Reyna

    2013-01-01

    Full Text Available Background. Exercise has an anti-inflammatory effect against, and immune cells play critical roles in the development, of insulin resistance and atherosclerotic vascular disease (AVD. Thus, the goal of this study was to determine whether exercise improves insulin sensitivity in insulin-resistant subjects by downregulating proinflammatory signaling in immune cells. Methods. Seventeen lean, 8 obese nondiabetic, and 11 obese type 2 diabetic individuals underwent an aerobic exercise program for 15 days and an insulin clamp before and after exercise. Peripheral mononuclear cells (PMNC were obtained for determination of Toll-like receptor (TLR 2 and 4 protein content and mitogen-activated protein kinase phosphorylation. Results. Compared with that in lean individuals, TLR4 protein content was increased by 4.2-fold in diabetic subjects. This increase in TLR4 content was accompanied by a 3.0-fold increase in extracellular signal-regulated kinase (ERK phosphorylation. Exercise improved insulin sensitivity in the lean, obese, and type 2 diabetes groups. However, exercise did not affect TLR content or ERK phosphorylation. Conclusions. TLR4 content and ERK phosphorylation are increased in PMNC of type 2 diabetic individuals. While exercise improves insulin sensitivity, this effect is not related to changes in TLR2/TLR4 content or ERK phosphorylation in PMNC of type 2 diabetic individuals.

  18. Short-term exercise training improves insulin sensitivity but does not inhibit inflammatory pathways in immune cells from insulin-resistant subjects.

    Science.gov (United States)

    Reyna, Sara M; Tantiwong, Puntip; Cersosimo, Eugenio; Defronzo, Ralph A; Sriwijitkamol, Apiradee; Musi, Nicolas

    2013-01-01

    Background. Exercise has an anti-inflammatory effect against, and immune cells play critical roles in the development, of insulin resistance and atherosclerotic vascular disease (AVD). Thus, the goal of this study was to determine whether exercise improves insulin sensitivity in insulin-resistant subjects by downregulating proinflammatory signaling in immune cells. Methods. Seventeen lean, 8 obese nondiabetic, and 11 obese type 2 diabetic individuals underwent an aerobic exercise program for 15 days and an insulin clamp before and after exercise. Peripheral mononuclear cells (PMNC) were obtained for determination of Toll-like receptor (TLR) 2 and 4 protein content and mitogen-activated protein kinase phosphorylation. Results. Compared with that in lean individuals, TLR4 protein content was increased by 4.2-fold in diabetic subjects. This increase in TLR4 content was accompanied by a 3.0-fold increase in extracellular signal-regulated kinase (ERK) phosphorylation. Exercise improved insulin sensitivity in the lean, obese, and type 2 diabetes groups. However, exercise did not affect TLR content or ERK phosphorylation. Conclusions. TLR4 content and ERK phosphorylation are increased in PMNC of type 2 diabetic individuals. While exercise improves insulin sensitivity, this effect is not related to changes in TLR2/TLR4 content or ERK phosphorylation in PMNC of type 2 diabetic individuals.

  19. Use of sensitivity, uncertainty and data adjustment analysis to improve nuclear data

    Energy Technology Data Exchange (ETDEWEB)

    Kodeli, I [CEA-Centre d' Etudes de Saclay, SERMA/LEPP, Gif sur Yvette (France); Sartori, E [OECD/ NEA Data Bank, Issy-les-Moulineaux (France); Remec, I [Inst. Jozef Stefan, Ljubljana (Slovenia)

    1992-07-01

    Sensitivity and adjustment analysis provide some valuable information about the radiation transport calculations. Together they give us a clear insight into the importance of different calculational parameters and tell us how much we can trust our result. Without this information the calculation cannot be considered as comprehensive. On the other hand the adjustment permits the improvement of our data base and thus reduces the uncertainty of our target quantities for a range of specific applications. With the objective to validate the methodology used in the reactor shielding analysis, these techniques were applied to PWR power plants, manufactured by EDF (52 capsules analysed in France) and Westinghouse (capsule and cavity dosimetry for the Krsko NPP in Slovenia), as well as to the ASPIS benchmark experiment. (author)

  20. Formation of double-layered TiO2 structures with selectively-positioned molecular dyes for efficient flexible dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Kim, Eun Yi; Yu, Sora; Moon, Jeong Hoon; Yoo, Seon Mi; Kim, Chulhee; Kim, Hwan Kyu; Lee, Wan In

    2013-01-01

    Graphical abstract: A novel flexible tandem dye-sensitized solar cell, selectively loading different dyes in discrete layers, was successfully formed on a plastic substrate by transferring the high-temperature-processed N719/TiO 2 over an organic dye-adsorbed TiO 2 film by a typical compression process at room temperature. -- Highlights: • A novel flexible dye-sensitized solar cell, selectively loading two different dyes in discrete layers, was successfully formed on a plastic substrate. • η of the flexible tandem cell obtained by transferring the high-temperature-processed TiO 2 layer was enhanced from 2.91% to 6.86%. • Interface control between two TiO 2 layers is crucial for the efficient transport of photo-injected electrons from the top to bottom TiO 2 layer. -- Abstract: To fabricate flexible dye-sensitized solar cells (DSCs) utilizing full solar spectrum, the double-layered TiO 2 films, selectively loading two different dyes in discrete layers, were formed on a plastic substrate by transferring the high-temperature-processed N719/TiO 2 over an organic dye (TA-St-CA)-sensitized TiO 2 film by a typical compression process at room temperature. It was found that interface control between two TiO 2 layers is crucial for the efficient transport of photo-injected electrons from the N719/TiO 2 to the TA-St-CA/TiO 2 layer. Electron impedance spectra (EIS) and transient photoelectron spectroscopic analyses exhibited that introduction of a thin interfacial TiO 2 layer between the two TiO 2 layers remarkably decreased the resistance at the interface, while increasing the electron diffusion constant (D e ) by ∼10 times. As a result, the photovoltaic conversion efficiency (η) of the flexible tandem DSC was 6.64%, whereas that of the flexible cell derived from the single TA-St-CA/TiO 2 layer was only 2.98%. Another organic dye (HC-acid), absorbing a short wavelength region of solar spectrum, was also applied to fabricate flexible tandem DSC. The η of the cell

  1. Mercaptosuccinic acid-coated NIR-emitting gold nanoparticles for the sensitive and selective detection of Hg2.

    Science.gov (United States)

    Xiong, Xiaodong; Lai, Xiaoqi; Liu, Jinbin

    2018-01-05

    A sensitive fluorescent detection platform for Hg 2+ was constructed based on mercaptosuccinic acid (MSA) coated near-infrared (NIR)-emitting gold nanoparticles (AuNPs). The thiolated mercaptosuccinic acid was employed as both reducing agent and surface coating ligand in a one-step synthesis of NIR-emitting AuNPs (MSA-AuNPs), which exhibited stable fluorescence with the maximum wavelength at 800nm and a wide range of excitation (220-650nm) with the maxima at 413nm. The MSA coated NIR-emitting AuNPs showed a rapid fluorescence quenching toward Hg 2+ over other metal ions with a limit of detection (LOD, 3δ) as low as 4.8nM. The sensing mechanism investigation revealed that the AuNPs formed aggregation due to the "recognition" of Hg 2+ from the MSA, and the resultant strong coupling interaction between Hg 2+ and Au (I) to further quench the fluorescence of the AuNPs, which synergistically resulted in a highly sensitive and selective fluorescence response toward Hg 2+ . This proposed strategy was also demonstrated the possibility to be used for Hg 2+ detection in water samples. Copyright © 2017. Published by Elsevier B.V.

  2. Mercaptosuccinic acid-coated NIR-emitting gold nanoparticles for the sensitive and selective detection of Hg2 +

    Science.gov (United States)

    Xiong, Xiaodong; Lai, Xiaoqi; Liu, Jinbin

    2018-01-01

    A sensitive fluorescent detection platform for Hg2 + was constructed based on mercaptosuccinic acid (MSA) coated near-infrared (NIR)-emitting gold nanoparticles (AuNPs). The thiolated mercaptosuccinic acid was employed as both reducing agent and surface coating ligand in a one-step synthesis of NIR-emitting AuNPs (MSA-AuNPs), which exhibited stable fluorescence with the maximum wavelength at 800 nm and a wide range of excitation (220-650 nm) with the maxima at 413 nm. The MSA coated NIR-emitting AuNPs showed a rapid fluorescence quenching toward Hg2 + over other metal ions with a limit of detection (LOD, 3δ) as low as 4.8 nM. The sensing mechanism investigation revealed that the AuNPs formed aggregation due to the "recognition" of Hg2 + from the MSA, and the resultant strong coupling interaction between Hg2 + and Au (I) to further quench the fluorescence of the AuNPs, which synergistically resulted in a highly sensitive and selective fluorescence response toward Hg2 +. This proposed strategy was also demonstrated the possibility to be used for Hg2 + detection in water samples.

  3. Laser correlation velocimetry performance in diesel applications: spatial selectivity and velocity sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Hespel, Camille [Universite d' Orleans, Laboratoire PRISME, Orleans (France); Blaisot, Jean-Bernard; Gazon, Matthieu; Godard, Gilles [CORIA, UMR 6614, CNRS, Universite et INSA de Rouen, Saint Etienne du Rouvray (France)

    2012-07-15

    The characterization of diesel jets in the near field of the nozzle exit still presents challenges for experimenters. Detailed velocity measurements are needed to characterize diesel injector performance and also to establish boundary conditions for CFD codes. The present article examines the efficiency of laser correlation velocimetry (LCV) applied to diesel spray characterization. A new optical configuration based on a long-distance microscope was tested, and special care was taken to examine the spatial selectivity of the technique. Results show that the depth of the measurement volume (along the laser beam) of LCV extends beyond the depth of field of the imaging setup. The LCV results were also found to be particularly sensitive to high-speed elements of a spray. Results from high-pressure diesel jets in a back-pressure environment indicate that this technique is particularly suited to the very near field of the nozzle exit, where the flow is the narrowest and where the velocity distribution is not too large. It is also shown that the performance of the LCV technique is controlled by the filtering and windowing parameters used in the processing of the raw signals. (orig.)

  4. Laser correlation velocimetry performance in diesel applications: spatial selectivity and velocity sensitivity

    Science.gov (United States)

    Hespel, Camille; Blaisot, Jean-Bernard; Gazon, Matthieu; Godard, Gilles

    2012-07-01

    The characterization of diesel jets in the near field of the nozzle exit still presents challenges for experimenters. Detailed velocity measurements are needed to characterize diesel injector performance and also to establish boundary conditions for CFD codes. The present article examines the efficiency of laser correlation velocimetry (LCV) applied to diesel spray characterization. A new optical configuration based on a long-distance microscope was tested, and special care was taken to examine the spatial selectivity of the technique. Results show that the depth of the measurement volume (along the laser beam) of LCV extends beyond the depth of field of the imaging setup. The LCV results were also found to be particularly sensitive to high-speed elements of a spray. Results from high-pressure diesel jets in a back-pressure environment indicate that this technique is particularly suited to the very near field of the nozzle exit, where the flow is the narrowest and where the velocity distribution is not too large. It is also shown that the performance of the LCV technique is controlled by the filtering and windowing parameters used in the processing of the raw signals.

  5. Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope

    International Nuclear Information System (INIS)

    Pandya, Shwetang N.; Sano, Ryuichi; Peterson, Byron J.; Mukai, Kiyofumi; Enokuchi, Akito; Takeyama, Norihide

    2014-01-01

    An Infrared imaging Video Bolometer (IRVB) diagnostic is currently being used in the Large Helical Device (LHD) for studying the localization of radiation structures near the magnetic island and helical divertor X-points during plasma detachment and for 3D tomography. This research demands high signal to noise ratio (SNR) and sensitivity to improve the temporal resolution for studying the evolution of radiation structures during plasma detachment and a wide IRVB field of view (FoV) for tomography. Introduction of an infrared periscope allows achievement of a higher SNR and higher sensitivity, which in turn, permits a twofold improvement in the temporal resolution of the diagnostic. Higher SNR along with wide FoV is achieved simultaneously by reducing the separation of the IRVB detector (metal foil) from the bolometer's aperture and the LHD plasma. Altering the distances to meet the aforesaid requirements results in an increased separation between the foil and the IR camera. This leads to a degradation of the diagnostic performance in terms of its sensitivity by 1.5-fold. Using an infrared periscope to image the IRVB foil results in a 7.5-fold increase in the number of IR camera pixels imaging the foil. This improves the IRVB sensitivity which depends on the square root of the number of IR camera pixels being averaged per bolometer channel. Despite the slower f-number (f/# = 1.35) and reduced transmission (τ 0 = 89%, due to an increased number of lens elements) for the periscope, the diagnostic with an infrared periscope operational on LHD has improved in terms of sensitivity and SNR by a factor of 1.4 and 4.5, respectively, as compared to the original diagnostic without a periscope (i.e., IRVB foil being directly imaged by the IR camera through conventional optics). The bolometer's field of view has also increased by two times. The paper discusses these improvements in apt details

  6. Improving the Quality of Basic Education through the Use of Gender-Sensitive Student Councils: Experience of Six Selected Districts in Tanzania

    Science.gov (United States)

    Mnubi, Godfrey Magoti

    2017-01-01

    This paper analyses whether the gender-sensitive and democratically elected student councils helped in strengthening school leadership and providing a platform for increased awareness and advocacy for male and female students to address their needs and rights in primary and secondary schools in Tanzania. The data were collected through qualitative…

  7. Valsartan Improves β-Cell Function and Insulin Sensitivity in Subjects With Impaired Glucose Metabolism

    Science.gov (United States)

    van der Zijl, Nynke J.; Moors, Chantalle C.M.; Goossens, Gijs H.; Hermans, Marc M.H.; Blaak, Ellen E.; Diamant, Michaela

    2011-01-01

    OBJECTIVE Recently, the Nateglinide and Valsartan in Impaired Glucose Tolerance Outcomes Research Trial demonstrated that treatment with the angiotensin receptor blocker (ARB) valsartan for 5 years resulted in a relative reduction of 14% in the incidence of type 2 diabetes in subjects with impaired glucose metabolism (IGM). We investigated whether improvements in β-cell function and/or insulin sensitivity underlie these preventive effects of the ARB valsartan in the onset of type 2 diabetes. RESEARCH DESIGN AND METHODS In this randomized controlled, double-blind, two-center study, the effects of 26 weeks of valsartan (320 mg daily; n = 40) or placebo (n = 39) on β-cell function and insulin sensitivity were assessed in subjects with impaired fasting glucose and/or impaired glucose tolerance, using a combined hyperinsulinemic-euglycemic and hyperglycemic clamp with subsequent arginine stimulation and a 2-h 75-g oral glucose tolerance test (OGTT). Treatment effects were analyzed using ANCOVA, adjusting for center, glucometabolic status, and sex. RESULTS Valsartan increased first-phase (P = 0.028) and second-phase (P = 0.002) glucose-stimulated insulin secretion compared with placebo, whereas the enhanced arginine-stimulated insulin secretion was comparable between groups (P = 0.25). In addition, valsartan increased the OGTT-derived insulinogenic index (representing first-phase insulin secretion after an oral glucose load; P = 0.027). Clamp-derived insulin sensitivity was significantly increased with valsartan compared with placebo (P = 0.049). Valsartan treatment significantly decreased systolic and diastolic blood pressure compared with placebo (P valsartan treatment increased glucose-stimulated insulin release and insulin sensitivity in normotensive subjects with IGM. These findings may partly explain the beneficial effects of valsartan in the reduced incidence of type 2 diabetes. PMID:21330640

  8. Improved sensitivity to venom specific-immunoglobulin E by spiking with the allergen component in Japanese patients suspected of Hymenoptera venom allergy.

    Science.gov (United States)

    Yoshida, Naruo; Hirata, Hirokuni; Watanabe, Mineaki; Sugiyama, Kumiya; Arima, Masafumi; Fukushima, Yasutsugu; Ishii, Yoshiki

    2015-07-01

    Ves v 5 and Pol d 5, which constitute antigen 5, are recognized as the major, most potent allergens of family Vespidae. Several studies have reported the diagnostic sensitivity of the novel recombinant (r)Ves v 5 and rPol d 5 allergens in routine clinical laboratory settings by analyzing a group of Vespula and Polistes venom-allergic patients. In this study, we analyzed the sensitivity to venom specific (s)IgE by spiking with rVes v 5 and rPol d 5 in Japanese patients suspected of Hymenoptera venom allergy. Subjects were 41 patients who had experienced systemic reactions to hornet and/or paper wasp stings. Levels of serum sIgE against hornet and paper wasp venom by spiking with rVes v 5 and rPold d 5, respectively, as improvement testing, compared with hornet and paper wasp venom, as conventional testing, were measured by ImmunoCAP. Of the 41 patients, 33 (80.5%) were positive (≥0.35 UA/ml) for hornet and/or paper wasp venom in conventional sIgE testing. sIgE levels correlated significantly (P venom (R = 0.78) in improvement testing and conventional testing. To determine specificity, 20 volunteers who had never experienced a Hymenoptera sting were all negative for sIgE against these venoms in both improvement and conventional testing. Improved sensitivity was seen in 8 patients negative for sIgE against both venoms in conventional testing, while improvement testing revealed sIgE against hornet or paper wasp venom in 5 (total 38 (92.7%)) patients. The measurement of sIgE following spiking of rVes v 5 and rPol d 5 by conventional testing in Japanese subjects with sIgE against hornet and paper wasp venom, respectively, improved the sensitivity for detecting Hymenoptera venom allergy. Improvement testing for measuring sIgE levels against hornet and paper wasp venom has potential for serologically elucidating Hymenoptera allergy in Japan. Copyright © 2015 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.

  9. Improvement of Toluene Selectivity via the Application of an Ethanol Oxidizing Catalytic Cell Upstream of a YSZ-Based Sensor for Air Monitoring Applications

    Science.gov (United States)

    Sato, Tomoaki; Breedon, Michael; Miura, Norio

    2012-01-01

    The sensing characteristics of a yttria-stabilized zirconia (YSZ)-based sensor utilizing a NiO sensing-electrode (SE) towards toluene (C7H8) and interfering gases (C3H6, H2, CO, NO2 and C2H5OH) were evaluated with a view to selective C7H8 monitoring in indoor atmospheres. The fabricated YSZ-based sensor showed preferential responses toward 480 ppb C2H5OH, rather than the target 50 ppb C7H8 at an operational temperature of 450 °C under humid conditions (RH ≃ 32%). To overcome this limitation, the catalytic activity of Cr2O3, SnO2, Fe2O3 and NiO powders were evaluated for their selective ethanol oxidation ability. Among these oxides, SnO2 was found to selectively oxidize C2H5OH, thus improving C7H8 selectivity. An inline pre-catalytic cell loaded with SnO2 powder was installed upstream of the YSZ-based sensor utilizing NiO-SE, which enabled the following excellent abilities by selectively catalyzing common interfering gases; sensitive ppb level detection of C7H8 lower than the established Japanese Guideline value; low interferences from 50 ppb C3H6, 500 ppb H2, 100 ppb CO, 40 ppb NO2, as well as 480 ppb C2H5OH. These operational characteristics are all indicative that the developed sensor may be suitable for real-time C7H8 concentration monitoring in indoor environments. PMID:22666053

  10. Fabrication of ultra-high sensitive and selective CH4 room temperature gas sensing of TiO2nanorods: Detailed study on the annealing temperature

    CSIR Research Space (South Africa)

    Tshabalala, Zamaswazi P

    2016-07-01

    Full Text Available Applications of ultra-highly sensitive and selective methane (CH(sub4)) room temperature gas sensors are important for various operations especially in underground mining environment. Therefore, this study is set out to investigate the effect...

  11. Bezafibrate ameliorates diabetes via reduced steatosis and improved hepatic insulin sensitivity in diabetic TallyHo mice

    Directory of Open Access Journals (Sweden)

    Andras Franko

    2017-03-01

    Full Text Available Objective: Recently, we have shown that Bezafibrate (BEZ, the pan-PPAR (peroxisome proliferator-activated receptor activator, ameliorated diabetes in insulin deficient streptozotocin treated diabetic mice. In order to study whether BEZ can also improve glucose metabolism in a mouse model for fatty liver and type 2 diabetes, the drug was applied to TallyHo mice. Methods: TallyHo mice were divided into an early (ED and late (LD diabetes progression group and both groups were treated with 0.5% BEZ (BEZ group or standard diet (SD group for 8 weeks. We analyzed plasma parameters, pancreatic beta-cell morphology, and mass as well as glucose metabolism of the BEZ-treated and control mice. Furthermore, liver fat content and composition as well as hepatic gluconeogenesis and mitochondrial mass were determined. Results: Plasma lipid and glucose levels were markedly reduced upon BEZ treatment, which was accompanied by elevated insulin sensitivity index as well as glucose tolerance, respectively. BEZ increased islet area in the pancreas. Furthermore, BEZ treatment improved energy expenditure and metabolic flexibility. In the liver, BEZ ameliorated steatosis, modified lipid composition and increased mitochondrial mass, which was accompanied by reduced hepatic gluconeogenesis. Conclusions: Our data showed that BEZ ameliorates diabetes probably via reduced steatosis, enhanced hepatic mitochondrial mass, improved metabolic flexibility and elevated hepatic insulin sensitivity in TallyHo mice, suggesting that BEZ treatment could be beneficial for patients with NAFLD and impaired glucose metabolism. Keywords: Bezafibrate, Glucose metabolism, Insulin resistance, Lipid metabolism, NAFLD

  12. Selective REM Sleep Deprivation Improves Expectation-Related Placebo Analgesia.

    Science.gov (United States)

    Chouchou, Florian; Chauny, Jean-Marc; Rainville, Pierre; Lavigne, Gilles J

    2015-01-01

    The placebo effect is a neurobiological and psychophysiological process known to influence perceived pain relief. Optimization of placebo analgesia may contribute to the clinical efficacy and effectiveness of medication for acute and chronic pain management. We know that the placebo effect operates through two main mechanisms, expectations and learning, which is also influenced by sleep. Moreover, a recent study suggested that rapid eye movement (REM) sleep is associated with modulation of expectation-mediated placebo analgesia. We examined placebo analgesia following pharmacological REM sleep deprivation and we tested the hypothesis that relief expectations and placebo analgesia would be improved by experimental REM sleep deprivation in healthy volunteers. Following an adaptive night in a sleep laboratory, 26 healthy volunteers underwent classical experimental placebo analgesic conditioning in the evening combined with pharmacological REM sleep deprivation (clonidine: 13 volunteers or inert control pill: 13 volunteers). Medication was administered in a double-blind manner at bedtime, and placebo analgesia was tested in the morning. Results revealed that 1) placebo analgesia improved with REM sleep deprivation; 2) pain relief expectations did not differ between REM sleep deprivation and control groups; and 3) REM sleep moderated the relationship between pain relief expectations and placebo analgesia. These results support the putative role of REM sleep in modulating placebo analgesia. The mechanisms involved in these improvements in placebo analgesia and pain relief following selective REM sleep deprivation should be further investigated.

  13. Synthesis of molecularly imprinted dye-silica nanocomposites with high selectivity and sensitivity: Fluorescent imprinted sensor for rapid and efficient detection of τ-fluvalinate in vodka.

    Science.gov (United States)

    Wang, Yunyun; Wang, Jixiang; Cheng, Rujia; Sun, Lin; Dai, Xiaohui; Yan, Yongsheng

    2018-04-01

    An imprinted fluorescent sensor was fabricated based on SiO 2 nanoparticles encapsulated with a molecularly imprinted polymer containing allyl fluorescein. High fluorine cypermethirin as template molecules, methyl methacrylate as functional monomer, and allyl fluorescein as optical materials synthesized a core-shell fluorescent molecular imprinted sensor, which showed a high and rapid sensitivity and selectivity for the detection of τ-fluvalinate. The sensor presented appreciable sensitivity with a limit of 13.251 nM, rapid detection that reached to equilibrium within 3 min, great linear relationship in the relevant concentration range from 0 to 150 nM, and excellent selectivity over structural analogues. In addition, the fluorescent sensor demonstrated desirable regeneration ability (eight cycling operations). The molecularly imprinted polymers ensured specificity, while the fluorescent dyes provided the stabile sensitivity. Finally, an effective application of the sensor was implemented by the detection of τ-fluvalinate in real samples from vodka. The molecularly imprinted fluorescent sensor showed a promising potential in environmental monitoring and food safety. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. rApi m 3 and rApi m 10 improve detection of honey bee sensitization in Hymenoptera venom-allergic patients with double sensitization to honey bee and yellow jacket venom.

    Science.gov (United States)

    Frick, M; Müller, S; Bantleon, F; Huss-Marp, J; Lidholm, J; Spillner, E; Jakob, T

    2015-12-01

    Recombinant allergens improve the diagnostic precision in Hymenoptera venom allergy (HVA), in particular in patients with double sensitization to both honey bee (HBV) and yellow jacket venom (YJV). While currently available vespid allergens allow the detection of >95% of YJV-allergic patients, the sensitization frequency to the only available HBV marker allergen rApi m 1 in HBV-allergic patients is lower. Here, we demonstrate that sIgE to additional HBV marker allergens rApi m 3 and rApi m 10 allows the detection of genuine HBV sensitization in 46-65% of Api m 1 negative sera. This is of particular relevance in patients with double sensitization to HBV and YJV that did not identify the culprit insect. Addition of sIgE to rApi m 3 and rApi m 10 provides evidence of HBV sensitization in a large proportion of rApi m 1-negative patients and thus provides a diagnostic marker and rationale for VIT treatment with HBV, which otherwise would have been missing. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Highly sensitive and selective room-temperature NO{sub 2} gas sensor based on bilayer transferred chemical vapor deposited graphene

    Energy Technology Data Exchange (ETDEWEB)

    Seekaew, Yotsarayuth [Department of Physics, Faculty of Science, Kasetsart University, Chatuchak, Bangkok 10900 (Thailand); Phokharatkul, Ditsayut; Wisitsoraat, Anurat [Nanoelectronics and MEMS Laboratory, National Electronics and Computer Technology Center, Klong Luang, Pathumthani 12120 (Thailand); Wongchoosuk, Chatchawal, E-mail: chatchawal.w@ku.ac.th [Department of Physics, Faculty of Science, Kasetsart University, Chatuchak, Bangkok 10900 (Thailand)

    2017-05-15

    Highlights: • Simple and low-cost fabrication of bilayer graphene gas sensor was presented. • Layer effects of graphene on NO{sub 2} gas-sensing properties were investigated. • Bilayer graphene sensor exhibited a high linear NO{sub 2} sensitivity of 1.409 ppm{sup −1}. • The NO{sub 2}-sensing mechanisms based on band diagram were highlighted. - Abstract: This work presents a highly sensitive room-temperature gas sensor based on bilayer graphene fabricated by an interfacial transfer of chemical vapor deposited graphene onto nickel interdigitated electrodes. Scanning electron microscopic and Raman spectroscopic characterizations confirm the presence of graphene on interdigitated nickel electrodes with varying numbers of graphene layers. The NO{sub 2} detection performances of bilayer graphene gas sensor have been investigated in comparison with those of monolayer and multilayer graphene gas sensors at room temperature. From results, the bilayer graphene gas sensor exhibits higher response, sensitivity and selectivity to NO{sub 2} than monolayer and multilayer graphene. The sensitivity of bilayer graphene gas sensor is 1.409 ppm{sup −1} towards NO{sub 2} over a concentration range of 1–25 ppm, which is more than twice higher than that of monolayer graphene. The NO{sub 2}-sensing mechanism of graphene sensing film has been explained based on the direct charge transfer process due to the adsorption of NO{sub 2} molecules.

  16. Aspartic acid-promoted highly selective and sensitive colorimetric sensing of cysteine in rat brain.

    Science.gov (United States)

    Qian, Qin; Deng, Jingjing; Wang, Dalei; Yang, Lifen; Yu, Ping; Mao, Lanqun

    2012-11-06

    Direct selective determination of cysteine in the cerebral system is of great importance because of the crucial roles of cysteine in physiological and pathological processes. In this study, we report a sensitive and selective colorimetric assay for cysteine in the rat brain with gold nanoparticles (Au-NPs) as the signal readout. Initially, Au-NPs synthesized with citrate as the stabilizer are red in color and exhibit absorption at 520 nm. The addition of an aqueous solution (20 μL) of cysteine or aspartic acid alone to a 200 μL Au-NP dispersion causes no aggregation, while the addition of an aqueous solution of cysteine into a Au-NP dispersion containing aspartic acid (1.8 mM) causes the aggregation of Au-NPs and thus results in the color change of the colloid from wine red to blue. These changes are ascribed to the ion pair interaction between aspartic acid and cysteine on the interface between Au-NPs and solution. The concentration of cysteine can be visualized with the naked eye and determined by UV-vis spectroscopy. The signal output shows a linear relationship for cysteine within the concentration range from 0.166 to 1.67 μM with a detection limit of 100 nM. The assay demonstrated here is highly selective and is free from the interference of other natural amino acids and other thiol-containing species as well as the species commonly existing in the brain such as lactate, ascorbic acid, and glucose. The basal dialysate level of cysteine in the microdialysate from the striatum of adult male Sprague-Dawley rats is determined to be around 9.6 ± 2.1 μM. The method demonstrated here is facile but reliable and durable and is envisaged to be applicable to understanding the chemical essence involved in physiological and pathological events associated with cysteine.

  17. Selective oxidation with nanoporous silica supported sensitizers: An environment friendly process using air and visible light

    Energy Technology Data Exchange (ETDEWEB)

    Saint-Cricq, Philippe; Pigot, Thierry; Blanc, Sylvie [Institut des Sciences Analytiques et de Physicochimie pour l' Environnement et les Materiaux, Universite de Pau et des Pays de l' Adour, Helioparc-2 Av. du President Angot, F-64053 Pau Cedex 09 (France); Lacombe, Sylvie, E-mail: sylvie.lacombe@univ-pau.fr [Institut des Sciences Analytiques et de Physicochimie pour l' Environnement et les Materiaux, Universite de Pau et des Pays de l' Adour, Helioparc-2 Av. du President Angot, F-64053 Pau Cedex 09 (France)

    2012-04-15

    Highlights: Black-Right-Pointing-Pointer Photo-sensitizers were covalently grafted on silica matrices. Black-Right-Pointing-Pointer Grafted powdered silica was characterized by diffuse reflectance and emission spectroscopy. Black-Right-Pointing-Pointer Selective solvent-free photo-oxygenation was carried out with air under visible light. Black-Right-Pointing-Pointer Singlet generation and reactivity at the gas-solid interface was demonstrated. - Abstract: Transparent and porous silica xerogels containing various grafted photosensitizers (PSs) such as anthraquinone derivatives, Neutral Red, Acridine Yellow and a laboratory-made dicyano aromatics (DBTP) were prepared. In most cases, the xerogels were shown to be mainly microporous by porosimetry. The PSs were characterized in the powdered monoliths (form, aggregation, concentration) by electronic spectroscopy which also proved to be a useful tool for monitoring the material evolution after irradiation. These nanoporous xerogels were used as microreactors for gas/solid solvent-free photo-oxygenation of dimethylsulfide (DMS) using visible light and air as the sole reactant. All these PSs containing monoliths were efficient for gas-solid DMS oxidation, leading to sulfoxide and sulfone in varying ratios. As these polar oxidation products remained strongly adsorbed on the silica matrix, the gaseous flow at the outlet of the reactor was totally free of sulfide and odorless. The best results in term of yield and initial rate of degradation of DMS were obtained with DBTP containing xerogels. Moreover, as these materials were reusable without loss of efficiency and sensitizer photobleaching after a washing regeneration step, the concept of recyclable sensitizing materials was approved, opening the way to green process.

  18. Improving radiochromic film's sensitivity by wrapping it with UV phosphor

    International Nuclear Information System (INIS)

    Geso, Moshi; Ackerly, Trevor; Patterson, William

    2004-01-01

    The main advantage of radiochromic-film dosimeters is the coupling of rapid full planar-acquisition, high-spatial resolution and dose linearity. Their main limitation, however, is their low radiation sensitivity. This precludes their application to measuring doses below a few Gy. Radiochromic films are sensitive to ultraviolet radiation. In this note the results of exposing radiochromic films to x rays through an UV imaging cassette, which converts and amplifies x rays to UV radiation, are presented. These results indicate a clear increase (around 50%) in radiochromic film's sensitivity to MV x rays (6, 10, and 18 MV) when exposed through the UV phosphor

  19. Mass hierarchy sensitivity of medium baseline reactor neutrino experiments with multiple detectors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong-Xin, E-mail: hxwang@iphy.me [Department of Physics, Nanjing University, Nanjing 210093 (China); Zhan, Liang; Li, Yu-Feng; Cao, Guo-Fu [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, Shen-Jian [Department of Physics, Nanjing University, Nanjing 210093 (China)

    2017-05-15

    We report the neutrino mass hierarchy (MH) determination of medium baseline reactor neutrino experiments with multiple detectors, where the sensitivity of measuring the MH can be significantly improved by adding a near detector. Then the impact of the baseline and target mass of the near detector on the combined MH sensitivity has been studied thoroughly. The optimal selections of the baseline and target mass of the near detector are ∼12.5 km and ∼4 kton respectively for a far detector with the target mass of 20 kton and the baseline of 52.5 km. As typical examples of future medium baseline reactor neutrino experiments, the optimal location and target mass of the near detector are selected for the specific configurations of JUNO and RENO-50. Finally, we discuss distinct effects of the reactor antineutrino energy spectrum uncertainty for setups of a single detector and double detectors, which indicate that the spectrum uncertainty can be well constrained in the presence of the near detector.

  20. High Sensitivity, Low Power Nano Sensors and Devices for Chemical Sensing

    Science.gov (United States)

    Li, Jing; Powell, Dan; Getty, Stephanie; Lu, Yi-Jiang

    2004-01-01

    The chemical sensor market has been projected to grow to better than $40 billion dollars worldwide within the next 10 years. Some of the primary motivations to develop nanostructured chemical sensors are monitoring and control of environmental pollution; improved diagnostics for consumption; improvement in measurement precision and accuracy; and improved detection limits for Homeland security, battlefield environments, and process and quality control of industrial applications. In each of these applications, there is demand for sensitivity, selectivity and stability of environmental and biohazard detection and capture beyond what is currently commercially available. Nanotechnology offers the ability to work at the molecular level, atom by atom, to create large structures with fundamentally new molecular organization. It is essentially concerned with materials, devices, and systems whose structures and components exhibit novel and significantly improved physical, chemical and biological properties, phenomena, and process control due to their nanoscale size. One such nanotechnology-enabled chemical sensor has been developed at NASA Ames leveraging nanostructures, such as single walled carbon nanotubes (SWNTs) and metal oxide nanobelts or nanowires, as a sensing medium bridging a pair of interdigitated electrodes (IDE) realized through a silicon-based microfabrication and micromachining technique. The DE fingers are fabricated on a silicon substrate using standard photolithography and thin film metallization techniques. It is noteworthy that the fabrication techniques employed are not confined to the silicon substrate. Through spin casting and careful substrate selection (i.e. clothing, glass, polymer, etc.), additional degrees of freedom can be exploited to enhance sensitivity or to conform to unique applications. Both in-situ growth of nanostructured materials and casting of nanostructured dispersions were used to produce analogous chemical sensing devices.

  1. Microcirculatory Improvement Induced by Laparoscopic Sleeve Gastrectomy Is Related to Insulin Sensitivity Retrieval.

    Science.gov (United States)

    Ministrini, Stefano; Fattori, Chiara; Ricci, Maria Anastasia; Bianconi, Vanessa; Paltriccia, Rita; Boni, Marcello; Paganelli, Maria Teresa; Vaudo, Gaetano; Lupattelli, Graziana; Pasqualini, Leonella

    2018-05-12

    Microvascular dysfunction is a potential factor explaining the association of obesity, insulin resistance, and vascular damage in morbidly obese subjects. The purpose of the study was to evaluate possible determinants of microcirculatory improvement 1 year after laparoscopic sleeve gastrectomy (LSG) intervention. Thirty-seven morbidly obese subjects eligible for bariatric surgery were included in the study. Post-occlusive reactive hyperemia (PORH) of the forearm skin was measured as area of hyperemia (AH) by laser-Doppler flowmetry before LSG and after a 1-year follow-up. After intervention, we observed a significant reduction in BMI, HOMA index, HbA1c, and a significant increase of AH in all patients after surgery; this variation was significant only in those patients having insulin resistance or prediabetes/diabetes. Although significant correlation between the increase of AH and the reduction of both BMI, HOMA index, and HbA1c was observed, BMI was the only independent predictor of AH variation after LSG at the linear regression analysis. Our study shows that LSG intervention is correlated with a significant improvement in the microvascular function of morbidly obese subjects; this improvement seems to be related to the baseline degree of insulin-resistance and to the retrieval of insulin-sensitivity post-intervention.

  2. An improved culture method for selective isolation of Campylobacter jejuni from wastewater

    Directory of Open Access Journals (Sweden)

    Jinyong Kim

    2016-08-01

    Full Text Available Campylobacter jejuni is one of the leading foodborne pathogens worldwide. C. jejuni is isolated from a wide range of foods, domestic animals, wildlife, and environmental sources. The currently-available culture-based isolation methods are not highly effective for wastewater samples due to the low number of C. jejuni in the midst of competing bacteria. To detect and isolate C. jejuni from wastewater samples, in this study, we evaluated a few different enrichment conditions using five different antibiotics (i.e., cefoperazone, vancomycin, trimethoprim, polymyxin B, and rifampicin, to which C. jejuni is intrinsically resistant. The selectivity of each enrichment condition was measured with Ct value using quantitative real-time PCR (qRT-PCR, and multiplex PCR to determine Campylobacter species. In addition, the efficacy of Campylobacter isolation on different culture media after selective enrichment was examined by growing on Bolton and Preston agar plates. The addition of polymyxin B, rifampicin, or both to the Bolton selective supplements enhanced the selective isolation of C. jejuni. In particular, rifampicin supplementation and an increased culture temperature (i.e., 42°C had a decisive effect on the selective enrichment of C. jejuni from wastewater. The results of 16S rDNA sequencing also revealed that Enterococcus spp. and Pseudomonas aeruginosa are major competing bacteria in the enrichment conditions. Although it is known to be difficult to isolate Campylobacter from samples with heavy contamination, this study well exhibited that the manipulation of antibiotic selective pressure improves the isolation efficiency of fastidious Campylobacter from wastewater.

  3. Max-AUC feature selection in computer-aided detection of polyps in CT colonography.

    Science.gov (United States)

    Xu, Jian-Wu; Suzuki, Kenji

    2014-03-01

    We propose a feature selection method based on a sequential forward floating selection (SFFS) procedure to improve the performance of a classifier in computerized detection of polyps in CT colonography (CTC). The feature selection method is coupled with a nonlinear support vector machine (SVM) classifier. Unlike the conventional linear method based on Wilks' lambda, the proposed method selected the most relevant features that would maximize the area under the receiver operating characteristic curve (AUC), which directly maximizes classification performance, evaluated based on AUC value, in the computer-aided detection (CADe) scheme. We presented two variants of the proposed method with different stopping criteria used in the SFFS procedure. The first variant searched all feature combinations allowed in the SFFS procedure and selected the subsets that maximize the AUC values. The second variant performed a statistical test at each step during the SFFS procedure, and it was terminated if the increase in the AUC value was not statistically significant. The advantage of the second variant is its lower computational cost. To test the performance of the proposed method, we compared it against the popular stepwise feature selection method based on Wilks' lambda for a colonic-polyp database (25 polyps and 2624 nonpolyps). We extracted 75 morphologic, gray-level-based, and texture features from the segmented lesion candidate regions. The two variants of the proposed feature selection method chose 29 and 7 features, respectively. Two SVM classifiers trained with these selected features yielded a 96% by-polyp sensitivity at false-positive (FP) rates of 4.1 and 6.5 per patient, respectively. Experiments showed a significant improvement in the performance of the classifier with the proposed feature selection method over that with the popular stepwise feature selection based on Wilks' lambda that yielded 18.0 FPs per patient at the same sensitivity level.

  4. Highly Selective and Sensitive Detection of Acetylcholine Using Receptor-Modified Single-Walled Carbon Nanotube Sensors

    Science.gov (United States)

    Xu, Shihong; Kim, Byeongju; Song, Hyun Seok; Jin, Hye Jun; Park, Eun Jin; Lee, Sang Hun; Lee, Byung Yang; Park, Tai Hyun; Hong, Seunghun

    2015-03-01

    Acetylcholine (ACh) is a neurotransmitter in a human central nervous system and is related to various neural functions such as memory, learning and muscle contractions. Dysfunctional ACh regulations in a brain can induce several neuropsychiatric diseases such as Alzheimer's disease, Parkinson's disease and myasthenia gravis. In researching such diseases, it is important to measure the concentration of ACh in the extracellular fluid of the brain. Herein, we developed a highly sensitive and selective ACh sensor based on single-walled carbon nanotube-field effect transistors (swCNT-FETs). In our work, M1 mAChR protein, an ACh receptor, was expressed in E.coli and coated on swCNT-FETs with lipid membranes. Here, the binding of ACh onto the receptors could be detected by monitoring the change of electrical currents in the underlying swCNT-FETs, allowing the real-time detection of ACh at a 100 pM concentration. Furthermore, our sensor could selectively detect ACh from other neurotransmitters. This is the first report of the real-time sensing of ACh utilizing specific binding between the ACh and M1 mAChR, and it may lead to breakthroughs in various biomedical applications such as drug screening and disease diagnosis.

  5. Clustering and training set selection methods for improving the accuracy of quantitative laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Ryan B., E-mail: randerson@astro.cornell.edu [Cornell University Department of Astronomy, 406 Space Sciences Building, Ithaca, NY 14853 (United States); Bell, James F., E-mail: Jim.Bell@asu.edu [Arizona State University School of Earth and Space Exploration, Bldg.: INTDS-A, Room: 115B, Box 871404, Tempe, AZ 85287 (United States); Wiens, Roger C., E-mail: rwiens@lanl.gov [Los Alamos National Laboratory, P.O. Box 1663 MS J565, Los Alamos, NM 87545 (United States); Morris, Richard V., E-mail: richard.v.morris@nasa.gov [NASA Johnson Space Center, 2101 NASA Parkway, Houston, TX 77058 (United States); Clegg, Samuel M., E-mail: sclegg@lanl.gov [Los Alamos National Laboratory, P.O. Box 1663 MS J565, Los Alamos, NM 87545 (United States)

    2012-04-15

    We investigated five clustering and training set selection methods to improve the accuracy of quantitative chemical analysis of geologic samples by laser induced breakdown spectroscopy (LIBS) using partial least squares (PLS) regression. The LIBS spectra were previously acquired for 195 rock slabs and 31 pressed powder geostandards under 7 Torr CO{sub 2} at a stand-off distance of 7 m at 17 mJ per pulse to simulate the operational conditions of the ChemCam LIBS instrument on the Mars Science Laboratory Curiosity rover. The clustering and training set selection methods, which do not require prior knowledge of the chemical composition of the test-set samples, are based on grouping similar spectra and selecting appropriate training spectra for the partial least squares (PLS2) model. These methods were: (1) hierarchical clustering of the full set of training spectra and selection of a subset for use in training; (2) k-means clustering of all spectra and generation of PLS2 models based on the training samples within each cluster; (3) iterative use of PLS2 to predict sample composition and k-means clustering of the predicted compositions to subdivide the groups of spectra; (4) soft independent modeling of class analogy (SIMCA) classification of spectra, and generation of PLS2 models based on the training samples within each class; (5) use of Bayesian information criteria (BIC) to determine an optimal number of clusters and generation of PLS2 models based on the training samples within each cluster. The iterative method and the k-means method using 5 clusters showed the best performance, improving the absolute quadrature root mean squared error (RMSE) by {approx} 3 wt.%. The statistical significance of these improvements was {approx} 85%. Our results show that although clustering methods can modestly improve results, a large and diverse training set is the most reliable way to improve the accuracy of quantitative LIBS. In particular, additional sulfate standards and

  6. Improved selectivity towards NO₂ of phthalocyanine-based chemosensors by means of original indigo/nanocarbons hybrid material.

    Science.gov (United States)

    Brunet, J; Pauly, A; Dubois, M; Rodriguez-Mendez, M L; Ndiaye, A L; Varenne, C; Guérin, K

    2014-09-01

    A new and original gas sensor-system dedicated to the selective monitoring of nitrogen dioxide in air and in the presence of ozone, has been successfully achieved. Because of its high sensitivity and its partial selectivity towards oxidizing pollutants (nitrogen dioxide and ozone), copper phthalocyanine-based chemoresistors are relevant. The selectivity towards nitrogen dioxide results from the implementation of a high efficient and selective ozone filter upstream the sensing device. Thus, a powdered indigo/nanocarbons hybrid material has been developed and investigated for such an application. If nanocarbonaceous material acts as a highly permeable matrix with a high specific surface area, immobilized indigo nanoparticles are involved into an ozonolysis reaction with ozone leading to the selective removal of this analytes from air sample. The filtering yields towards each gas have been experimentally quantified and establish the complete removal of ozone while having the concentration of nitrogen dioxide unchanged. Long-term gas exposures reveal the higher durability of hybrid material as compared to nanocarbons and indigo separately. Synthesis, characterizations by many complementary techniques and tests of hybrid filters are detailed. Results on sensor-system including CuPc-based chemoresistors and indigo/carbon nanotubes hybrid material as in-line filter are illustrated. Sensing performances will be especially discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Improved Composite Gel Electrolyte by Layered Vermiculite for Quasi-Solid-State Dye-Sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    Hongcai He

    2014-01-01

    Full Text Available A composite quasisolid electrolyte is prepared by adding a layered vermiculite (VMT into the iodide/triiodide electrolyte including 4-tert-butylpyridine, which obviously improves the photovoltaic properties of quasisolid dye-sensitized solar cells (DSSCs. When adding 6 wt% VMT, the maximum photovoltaic conversion efficiency of 3.89% is obtained, which reaches more than two times greater than that without VMT. This enhancement effect is primarily explained by studying the Nyquist spectra, dark currents, and photovoltaic conversion efficiency.

  8. Improving the Design of Capacitive Micromachined Ultrasonic Transducers Aided with Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    A Martowicz

    2016-09-01

    Full Text Available The paper presents the results of analysis performed to search for feasible design improvements for capacitive micromachined ultrasonic transducer. Carried out search has been aided with the sensitivity analysis and the application of Response Surface Method. The multiphysics approach has been taken into account in elaborated finite element model of one cell of described transducer in order to include significant physical phenomena present in modelled microdevice. The set of twelve input uncertain and design parameters consists of geometric, material and control properties. The amplitude of dynamic membrane deformation of the transducer has been chosen as studied parameter. The objective of performed study has been defined as the task of finding robust design configurations of the transducer, i.e. characterizing maximal value of deformation amplitude with its minimal variation.

  9. Sensitivity improvement of an electrical sensor achieved by control of biomolecules based on the negative dielectrophoretic force.

    Science.gov (United States)

    Kim, Hye Jin; Kim, Jinsik; Yoo, Yong Kyoung; Lee, Jeong Hoon; Park, Jung Ho; Hwang, Kyo Seon

    2016-11-15

    Effective control of nano-scale biomolecules can enhance the sensitivity and limit of detection of an interdigitated microelectrode (IME) sensor. Manipulation of the biomolecules by dielectrophoresis (DEP), especially the negative DEP (nDEP) force, so that they are trapped between electrodes (sensing regions) was predicted to increase the binding efficiency of the antibody and target molecules, leading to a more effective reaction. To prove this concept, amyloid beta 42 (Aβ42) and prostate specific antigen (PSA) protein were respectively trapped between the sensing region owing to the nDEP force under 5V and 0.05V, which was verified with COMSOL simulation. Using the simulation value, the resistance change (ΔR/Rb) of the IME sensor from the specific antibody-antigen reaction of the two biomolecules and the change in fluorescence intensity were compared in the reference (pDEP) and nDEP conditions. The ΔR/Rb value improved by about 2-fold and 1.66-fold with nDEP compared to the reference condition with various protein concentrations, and these increases were confirmed with fluorescence imaging. Overall, nDEP enhanced the detection sensitivity for Aβ42 and PSA by 128% and 258%, respectively, and the limit of detection improved by up to 2-orders of magnitude. These results prove that DEP can improve the biosensor's performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Enhancement of NH3 Gas Sensitivity at Room Temperature by Carbon Nanotube-Based Sensor Coated with Co Nanoparticles

    Directory of Open Access Journals (Sweden)

    Lich Quang Nguyen

    2013-01-01

    Full Text Available Multi-walled carbon nanotube (MWCNT film has been fabricated onto Pt-patterned alumina substrates using the chemical vapor deposition method for NH3 gas sensing applications. The MWCNT-based sensor is sensitive to NH3 gas at room temperature. Nanoclusters of Co catalysts have been sputtered on the surface of the MWCNT film to enhance gas sensitivity with respect to unfunctionalized CNT films. The gas sensitivity of Co-functionalized MWCNT-based gas sensors is thus significantly improved. The sensor exhibits good repeatability and high selectivity towards NH3, compared with alcohol and LPG.

  11. Engineering Sensitivity Improvement of Helium Mass Spectrometer Leak Detection System by Means Global Hard Vacuum Test

    International Nuclear Information System (INIS)

    Sigit Asmara Santa

    2006-01-01

    The engineering sensitivity improvement of Helium mass spectrometer leak detection using global hard vacuum test configuration has been done. The purpose of this work is to enhance the sensitivity of the current leak detection of pressurized method (sniffer method) with the sensitivity of 10 -3 ∼ 10 -5 std cm 3 /s, to the global hard vacuum test configuration method which can be achieved of up to 10 -8 std cm 3 /s. The goal of this research and development is to obtain a Helium leak test configuration which is suitable and can be used as routine bases in the quality control tests of FPM capsule and AgInCd safety control rod products. The result is an additional instrumented vacuum tube connected with conventional Helium mass spectrometer. The pressure and temperature of the test object during the leak measurement are simulated by means of a 4.1 kW capacity heater and Helium injection to test object, respectively. The addition of auxiliary mechanical vacuum pump of 2.4 l/s pumping speed which is directly connected to the vacuum tube, will reduce 86 % of evacuation time. The reduction of the measured sensitivity due to the auxiliary mechanical vacuum pump can be overcome by shutting off the pump soon after Helium mass spectrometer reaches its operating pressure condition. (author)

  12. Label-free electrochemical aptasensor constructed by layer-by-layer technology for sensitive and selective detection of cancer cells.

    Science.gov (United States)

    Wang, Tianshu; Liu, Jiyang; Gu, Xiaoxiao; Li, Dan; Wang, Jin; Wang, Erkang

    2015-07-02

    Here, a cytosensor was constructed with ferrocene-appended poly(allylamine hydrochloride) (Fc-PAH) functionalized graphene (Fc-PAH-G), poly(sodium-p-styrenesulfonate) (PSS) and aptamer (AS1411) by layer-by-layer assembly technology. The hybrid nanocomposite Fc-PAH-G not only brings probes on the electrode and also promotes electron transfer between the probes and the substrate electrode. Meanwhile, LBL technology provides more effective probes to enhance amplified signal for improving the sensitivity of the detection. While AS1411 forming G-quardruplex structure and binding cancer cells, the current response of the sensing electrode decreased due to the insulating properties of cellular membrane. Differential pulse voltammetry (DPV) was performed to investigate the electrochemical detection of HeLa cells attributing to its sensitivity of the current signal change. The as-prepared aptasensor showed a high sensitivity and good stability, a widely detection range from 10 to 10(6) cells/mL with a detection limit as low as 10 cells/mL for the detection of cancer cells. Copyright © 2015. Published by Elsevier B.V.

  13. A Copula Based Approach for Design of Multivariate Random Forests for Drug Sensitivity Prediction.

    Science.gov (United States)

    Haider, Saad; Rahman, Raziur; Ghosh, Souparno; Pal, Ranadip

    2015-01-01

    Modeling sensitivity to drugs based on genetic characterizations is a significant challenge in the area of systems medicine. Ensemble based approaches such as Random Forests have been shown to perform well in both individual sensitivity prediction studies and team science based prediction challenges. However, Random Forests generate a deterministic predictive model for each drug based on the genetic characterization of the cell lines and ignores the relationship between different drug sensitivities during model generation. This application motivates the need for generation of multivariate ensemble learning techniques that can increase prediction accuracy and improve variable importance ranking by incorporating the relationships between different output responses. In this article, we propose a novel cost criterion that captures the dissimilarity in the output response structure between the training data and node samples as the difference in the two empirical copulas. We illustrate that copulas are suitable for capturing the multivariate structure of output responses independent of the marginal distributions and the copula based multivariate random forest framework can provide higher accuracy prediction and improved variable selection. The proposed framework has been validated on genomics of drug sensitivity for cancer and cancer cell line encyclopedia database.

  14. Purifying Selection Maintains Dosage-Sensitive Genes during Degeneration of the Threespine Stickleback Y Chromosome

    Science.gov (United States)

    White, Michael A.; Kitano, Jun; Peichel, Catherine L.

    2015-01-01

    Sex chromosomes are subject to unique evolutionary forces that cause suppression of recombination, leading to sequence degeneration and the formation of heteromorphic chromosome pairs (i.e., XY or ZW). Although progress has been made in characterizing the outcomes of these evolutionary processes on vertebrate sex chromosomes, it is still unclear how recombination suppression and sequence divergence typically occur and how gene dosage imbalances are resolved in the heterogametic sex. The threespine stickleback fish (Gasterosteus aculeatus) is a powerful model system to explore vertebrate sex chromosome evolution, as it possesses an XY sex chromosome pair at relatively early stages of differentiation. Using a combination of whole-genome and transcriptome sequencing, we characterized sequence evolution and gene expression across the sex chromosomes. We uncovered two distinct evolutionary strata that correspond with known structural rearrangements on the Y chromosome. In the oldest stratum, only a handful of genes remain, and these genes are under strong purifying selection. By comparing sex-linked gene expression with expression of autosomal orthologs in an outgroup, we show that dosage compensation has not evolved in threespine sticklebacks through upregulation of the X chromosome in males. Instead, in the oldest stratum, the genes that still possess a Y chromosome allele are enriched for genes predicted to be dosage sensitive in mammals and yeast. Our results suggest that dosage imbalances may have been avoided at haploinsufficient genes by retaining function of the Y chromosome allele through strong purifying selection. PMID:25818858

  15. Developed beverage from roselle calyx and selected fruits modulates β-cell function, improves insulin sensitivity, and attenuates hyperlipidaemia in diabetic rats

    Directory of Open Access Journals (Sweden)

    Ochuko L. Erukainure

    2015-12-01

    Full Text Available The aim of this study is to report the antidiabetic properties of a beverage developed from roselle calyx and selected fruits in male albino rats. The beverage was designed to contain 30% pawpaw (Carica papaya L., 10% grapefruit (Citrus paradisi, 20% guava leaves (Psidium guajava L. and 40% roselle calyx aqueous extracts. Four groups of five rats each were acclimatized on pelletized mouse chow for seven days, after which diabetes was induced by a single ip injection of alloxan in all groups except group 1, which served as control. Group 2 served as negative control while groups 3 and 4 were treated with the beverage at 2.5 and 5 ml/kg bw respectively. Food intake, body weight, and blood glucose levels were monitored. They were sacrificed by cervical dislocation after a 2 week treatment. Blood serum was analysed to evaluate insulin levels, β cell function, insulin resistance and lipid profile. Histological studies were carried out on pancreatic tissues. Treatment with both doses of the beverage led to a significant reduction (p < 0.05 in blood glucose, total cholesterol triglyceride, LDL and increased HDL levels. It also improved serum insulin levels, β cell function, reduced insulin resistance and restored pancreatic beta cells compared to the diabetic group. These antidiabetic properties may be as a consequence of modulation of the β-cell function, reduction of insulin resistance and preservation/restoration of β-cell integrity. However, treatment with the single dose showed signs of hyperinsulinaemia.

  16. A hydrogel biosensor for high selective and sensitive detection of amyloid-beta oligomers

    Directory of Open Access Journals (Sweden)

    Sun LP

    2018-02-01

    Full Text Available Liping Sun,1 Yong Zhong,1 Jie Gui,1 Xianwu Wang,1 Xiaorong Zhuang,2 Jian Weng1 1Key Laboratory of Biomedical Engineering of Fujian Province, Research Center of Biomedical Engineering of Xiamen, Department of Biomaterials, College of Materials, Xiamen University, 2Department of Neurology, The Affiliated Zhongshan Hospital of Xiamen University, Xiamen, People’s Republic of China Background: Alzheimer’s disease (AD is a neurodegenerative disorder characterized by progressive cognitive and memory impairment. It is the most common neurological disease that causes dementia. Soluble amyloid-beta oligomers (AβO in blood or cerebrospinal fluid (CSF are the pathogenic biomarker correlated with AD. Methods: A simple electrochemical biosensor using graphene oxide/gold nanoparticles (GNPs hydrogel electrode was developed in this study. Thiolated cellular prion protein (PrPC peptide probe was immobilized on GNPs of the hydrogel electrode to construct an AβO biosensor. Electrochemical impedance spectroscopy was utilized for AβO analysis. Results: The specific binding between AβO and PrPC probes on the hydrogel electrode resulted in an increase in the electron-transfer resistance. The biosensor showed high specificity and sensitivity for AβO detection. It could selectively differentiate AβO from amyloid-beta (Aβ monomers or fibrils. Meanwhile, it was highly sensitive to detect as low as 0.1 pM AβO in artificial CSF or blood plasma. The linear range for AβO detection is from 0.1 pM to 10 nM. Conclusion: This biosensor could be used as a cost-effective tool for early diagnosis of AD due to its high electrochemical performance and bionic structure. Keywords: Alzheimer’s disease, amyloid-beta oligomer, graphene, gold nanoparticles, biosensor

  17. Genetic characterization of Russian honey bee stock selected for improved resistance to Varroa destructor.

    Science.gov (United States)

    Bourgeois, A Lelania; Rinderer, Thomas E

    2009-06-01

    Maintenance of genetic diversity among breeding lines is important in selective breeding and stock management. The Russian Honey Bee Breeding Program has strived to maintain high levels of heterozygosity among its breeding lines since its inception in 1997. After numerous rounds of selection for resistance to tracheal and varroa mites and improved honey production, 18 lines were selected as the core of the program. These lines were grouped into three breeding blocks that were crossbred to improve overall heterozygosity levels of the population. Microsatellite DNA data demonstrated that the program has been successful. Heterozygosity and allelic richness values are high and there are no indications of inbreeding among the three blocks. There were significant levels of genetic structure measured among the three blocks. Block C was genetically distinct from both blocks A and B (F(ST) = 0.0238), whereas blocks A and B did not differ from each other (F(ST) = 0.0074). The same pattern was seen for genic (based on numbers of alleles) differentiation. Genetic distance, as measured by chord distance, indicates that all of the 18 lines are equally distant, with minimal clustering. The data indicate that the overall design of the breeding program has been successful in maintaining high levels of diversity and avoiding problems associated with inbreeding.

  18. Features of conflict sensitivity implementation mechanisms’ in the public sector projects

    Directory of Open Access Journals (Sweden)

    T. V. Маматоvа

    2017-08-01

    Full Text Available It has been found in the study that potential conflicts are natural for public sector projects. Among the factors, that predetermine it, one can distinguish the following: the opposite to the processes of making changes; competition of participants during the allocation of project resources; different opportunities to access the project product; insufficient consideration of interested parties’ interests; context conflicts; directing the project to resolve the conflict in the territory; unsuccessful selection of the project team. Consequently, the article deals with the issues related to the definition of the peculiarities of the «conflict sensitivity» implementation mechanisms in the public sector projects. This topic has not been studied thoroughly in the specialized publications on public administration in Ukraine. Definitions of main related categories of the «conflict sensitivity» domain based on Conflict Sensitivity Consortium guidelines have been described in the study: «conflict sensitivity», «conflict», «conflict analysis», «conflict sensitivity analysis». The main ideas on the peculiarities of conflict-sensitive project / program management implementation mechanisms in the context of ensuring the success of local development projects by the integration of «conflict sensitivity» into all three phases of the project cycle, under which the intervention is implemented, are as follows: conflict-sensitive planning; conflict-sensitive implementation; conflict-sensitive monitoring and evaluation. The example of the conflict-sensitive project management use is: EUNPACK international project «Good intentions, mixed results – A conflict sensitive understanding of the EU comprehensive approach to conflict and crisis mechanisms», which aims to develop recommendations on the improvement of the EU crises response mechanisms by the increase of their sensitivity to conflict and context. As a result, prospects for further research

  19. Emotion improves and impairs early vision.

    Science.gov (United States)

    Bocanegra, Bruno R; Zeelenberg, René

    2009-06-01

    Recent studies indicate that emotion enhances early vision, but the generality of this finding remains unknown. Do the benefits of emotion extend to all basic aspects of vision, or are they limited in scope? Our results show that the brief presentation of a fearful face, compared with a neutral face, enhances sensitivity for the orientation of subsequently presented low-spatial-frequency stimuli, but diminishes orientation sensitivity for high-spatial-frequency stimuli. This is the first demonstration that emotion not only improves but also impairs low-level vision. The selective low-spatial-frequency benefits are consistent with the idea that emotion enhances magnocellular processing. Additionally, we suggest that the high-spatial-frequency deficits are due to inhibitory interactions between magnocellular and parvocellular pathways. Our results suggest an emotion-induced trade-off in visual processing, rather than a general improvement. This trade-off may benefit perceptual dimensions that are relevant for survival at the expense of those that are less relevant.

  20. Sensitivity Analysis of Fire Dynamics Simulation

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter V.; Petersen, Arnkell J.

    2007-01-01

    (Morris method). The parameters considered are selected among physical parameters and program specific parameters. The influence on the calculation result as well as the CPU time is considered. It is found that the result is highly sensitive to many parameters even though the sensitivity varies...

  1. Radiation vulcanization of natural rubber latex sensitized with commercial gases

    International Nuclear Information System (INIS)

    Chirinos, H.; Lugao, A.

    2002-01-01

    The industrial activities using natural rubber latex are fully compatible with rural areas in Amazon and other places in Brazil, as well as in other tropical countries. However the classical sulfur vulcanization presents many occupational problems for the workers in rural areas. Radiation vulcanization of natural rubber latex is a much more friendly process as sulfur compounds are not needed for crosslinking, although chemicals as acrylate monomers, particularly multifunctional acrylates are still used as sensitizers for radiation processes. Two commercial gases, acetylene and butadiene, were selected as sensitizers for the radiation vulcanization of natural rubber latex instead of acrylates. These gases accelerate the crosslinking rates of the cure process and lower the radiation dose required to achieve vulcanization of natural rubber latex and improve the mechanical properties to reduce the tackiness of rubber goods. (author)

  2. Radiation vulcanization of natural rubber latex sensitized with commercial gases

    Energy Technology Data Exchange (ETDEWEB)

    Chirinos, H.; Lugao, A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2002-07-01

    The industrial activities using natural rubber latex are fully compatible with rural areas in Amazon and other places in Brazil, as well as in other tropical countries. However the classical sulfur vulcanization presents many occupational problems for the workers in rural areas. Radiation vulcanization of natural rubber latex is a much more friendly process as sulfur compounds are not needed for crosslinking, although chemicals as acrylate monomers, particularly multifunctional acrylates are still used as sensitizers for radiation processes. Two commercial gases, acetylene and butadiene, were selected as sensitizers for the radiation vulcanization of natural rubber latex instead of acrylates. These gases accelerate the crosslinking rates of the cure process and lower the radiation dose required to achieve vulcanization of natural rubber latex and improve the mechanical properties to reduce the tackiness of rubber goods. (author)

  3. Selection and application of microorganisms to improve oil recovery

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, P.F.; Moreira, R.S.; Almeida, R.C.C.; Guimaraes, A.K.; Carvalho, A.S. [Laboratorio de Biotecnologia e Ecologia de Microrganismos da Universidade Federal da Bahia, Avenida Reitor Miguel Calmon, s/n, Vale do Canela, CEP 41.160-100 Salvador BA (Brazil); Quintella, C.; Esperidia, M.C.A. [Instituto de Quimica da Universidade Federal da Bahia, Rua Barao de Geremoabo, s/n, Campus Universitario de Ondina, CEP 40.170-290, Salvador BA (Brazil); Taft, C.A. [Centro Brasileiro de Pesquisas Fisicas, Rua Xavier Sigaud, 150, Urca, 22290-180, Rio de Janeiro (Brazil)

    2004-08-01

    Microbial enhanced oil recovery (Meor) is an incontestably efficient alternative to improve oil recovery, especially in mature fields and in oil reservoirs with high paraffinic content. This is the case for most oil fields in the Reconcavo basin of Bahia, Brazil. Given the diverse conditions of most oil fields, an approach to apply Meor technology should consider primarily: (i) microbiological studies to select the appropriate microorganisms and (ii) mobilization of oil in laboratory experiments before oil field application. A total of 163 bacterial strains, selectively isolated from various sources, were studied to determine their potential to be used in Meor. A laboratory microbial screening based on physiological and metabolic profiles and growth rates under conditions representative for oil fields and reservoirs revealed that 10 bacterial strains identified as Pseudomonas aeruginosa (2), Bacillus licheniformis (2), Bacillus brevis (1), Bacillus polymyxa (1), Micrococcus varians (1), Micrococcus sp. (1), and two Vibrio species demonstrated potential to be used in oil recovery. Strains of B. licheniformis and B. polymyxa produced the most active surfactants and proved to be the most anaerobic and thermotolerant among the selected bacteria. Micrococcus and B. brevis were the most salt-tolerant and polymer producing bacteria, respectively, whereas Vibrio sp. and B. polymyxa strains were the most gas-producing bacteria. Three bacterial consortia were prepared with a mixture of bacteria that showed metabolic and technological complementarity and the ability to grow at a wide range of temperatures and salinity characteristics for the oil fields in Bahia, Brazil. Oil mobilization rates in laboratory column experiments using the three consortia of bacteria varied from 11.2 to 18.3 % [v/v] of the total oil under static conditions. Consortia of B. brevis, B. icheniformis and B. polymyxa exhibited the best oil mobilization rates. Using these consortia under anaerobic

  4. Targeted drug delivery using temperature-sensitive liposomes

    International Nuclear Information System (INIS)

    Magin, R.L.; Niesman, M.R.

    1984-01-01

    Liposomes are receiving considerable attention as vehicles for selective drug delivery. One method of targeting liposomal contents involves the combination of local hyperthermia with temperature-sensitive liposomes. Such liposomes have been used to increase the uptake of methotrexate and cis-platinum into locally heated mouse tumors. However, additional information is needed on the mechanism of liposome drug release and the physiologic deposition of liposomes in vivo before clinical trails are begun. Current research is directed at studying the encapsulation and release of water soluble drugs from temperature-sensitive liposomes. The influence of liposome size, structure, and composition on the rapid release in plasma of cytosine arabinoside, cis-platinum, and the radiation sensitizer SR-2508 are described. These results demonstrate potential applications for temperature-sensitive liposomes in selective drug delivery

  5. Sensitive and selective determination of Cu2+ at D-penicillamine functionalized nano-cellulose modified pencil graphite electrode

    Science.gov (United States)

    Taheri, M.; Ahour, F.; Keshipour, S.

    2018-06-01

    A novel electrochemical sensor based on D-penicillamine anchored nano-cellulose (DPA-NC) modified pencil graphite electrode was fabricated and used for highly selective and sensitive determination of copper (II) ions in the picomolar concentration by square wave adsorptive stripping voltammetric (SWV) method. The modified electrode showed better and increased SWV response compared to the bare and NC modified electrodes which may be related to the porous structure of modifier along with formation of complex between Cu2+ ions and nitrogen or oxygen containing groups in DPA-NC. Optimization of various experimental parameters influence the performance of the sensor, were investigated. Under optimized condition, DPA-NC modified electrode was used for the analysis of Cu2+ in the concentration range from 0.2 to 50 pM, and a lower detection limit of 0.048 pM with good stability, repeatability, and selectivity. Finally, the practical applicability of DPA-NC-PGE was confirmed via measuring trace amount of Cu (II) in tap and river water samples.

  6. Sound improves diminished visual temporal sensitivity in schizophrenia

    NARCIS (Netherlands)

    de Boer-Schellekens, L.; Stekelenburg, J.J.; Maes, J.P.; van Gool, A.R.; Vroomen, J.

    2014-01-01

    Visual temporal processing and multisensory integration (MSI) of sound and vision were examined in individuals with schizophrenia using a visual temporal order judgment (TOJ) task. Compared to a non-psychiatric control group, persons with schizophrenia were less sensitive judging the temporal order

  7. Sensors based on mesoporous SnO{sub 2}-CuWO{sub 4} with high selective sensitivity to H{sub 2}S at low operating temperature

    Energy Technology Data Exchange (ETDEWEB)

    Stanoiu, Adelina; Simion, Cristian E. [National Institute of Materials Physics, Atomistilor 405A, P.O. Box MG-7, 077125 Bucharest, Măgurele (Romania); Calderon-Moreno, Jose Maria; Osiceanu, Petre [“Ilie Murgulescu” Institute of Physical Chemistry, Romanian Academy, Surface Chemistry and Catalysis Laboratory, Spl. Independentei 202, 060021, Bucharest (Romania); Florea, Mihaela [University of Bucharest, Faculty of Chemistry, Department of Organic Chemistry, Biochemistry and Catalysis, B-dul Regina Elisabeta 4-12, Bucharest (Romania); National Institute of Materials Physics, Atomistilor 405A, P.O. Box MG-7, 077125 Bucharest, Măgurele (Romania); Teodorescu, Valentin S. [National Institute of Materials Physics, Atomistilor 405A, P.O. Box MG-7, 077125 Bucharest, Măgurele (Romania); Somacescu, Simona, E-mail: somacescu.simona@gmail.com [“Ilie Murgulescu” Institute of Physical Chemistry, Romanian Academy, Surface Chemistry and Catalysis Laboratory, Spl. Independentei 202, 060021, Bucharest (Romania)

    2017-06-05

    Highlights: • Mesoporous SnO{sub 2}-CuWO{sub 4} obtained by an inexpensive synthesis route. • Powders characterization performed by a variety of complementary techniques. • SnO{sub 2}-CuWO{sub 4} layers with high selective sensitivity to H{sub 2}S. • Low operating temperature and relative humidity influences. - Abstract: Development of new sensitive materials by different synthesis routes in order to emphasize the sensing properties for hazardous H{sub 2}S detection is one of a nowadays challenge in the field of gas sensors. In this study we obtained mesoporous SnO{sub 2}-CuWO{sub 4} with selective sensitivity to H{sub 2}S by an inexpensive synthesis route with low environmental pollution level, using tripropylamine (TPA) as template and polyvinylpyrrolidone (PVP) as dispersant/stabilizer. In order to bring insights about the intrinsic properties, the powders were characterized by means of a variety of complementary techniques such as: X-Ray Diffraction, XRD; Transmission Electron Microscopy, TEM; High Resolution TEM, HRTEM; Raman Spectroscopy, RS; Porosity Analysis by N{sub 2} adsorption/desorption, BET; Scanning Electron Microscopy, SEM and X-ray Photoelectron Spectroscopy, XPS. The sensors were fabricated by powders deposition via screen-printing technique onto planar commercial Al{sub 2}O{sub 3} substrates. The sensor signals towards H{sub 2}S exposure at low operating temperature (100 °C) reaches values from 10{sup 5} (for SnWCu600) to 10{sup 6} (for SnWCu800) over the full range of concentrations (5–30 ppm). The recovery processes were induced by a short temperature trigger of 500 °C. The selective sensitivity was underlined with respect to the H{sub 2}S, relative to other potential pollutants and relative humidity (10–70% RH).

  8. Sensitivity to selected contaminants in a biological early warning ...

    African Journals Online (AJOL)

    Several early warning systems for the monitoring of water quality are based on the assessment of valve opening/closing in bivalves. Tests were conducted to assess the sensitivity of the mussel Anodonta woodiana, installed on the Mosselmonitor, to seven contaminants and evaluate the usefulness of these sensors for ...

  9. Development of the method of sensitivity improvement of photographic film applicable in high-energy physics experiments

    International Nuclear Information System (INIS)

    Gokieli, V.D.

    1986-01-01

    Sensitivity improvement of photographic films applicable in high-energy physics experiments is discussed. To get optimal operating conditions for photographic film PT-6 to check its physical properties on electron beam and in cosmic rays a set for film samples exposure in visible spectrum and in X-rays is constructed. The set includes a start up device, high-voltage pulse oscillator, shapers, a chamber for the sample exposure, voltage divider and electron oscillograph

  10. Road network selection for small-scale maps using an improved centrality-based algorithm

    Directory of Open Access Journals (Sweden)

    Roy Weiss

    2014-12-01

    Full Text Available The road network is one of the key feature classes in topographic maps and databases. In the task of deriving road networks for products at smaller scales, road network selection forms a prerequisite for all other generalization operators, and is thus a fundamental operation in the overall process of topographic map and database production. The objective of this work was to develop an algorithm for automated road network selection from a large-scale (1:10,000 to a small-scale database (1:200,000. The project was pursued in collaboration with swisstopo, the national mapping agency of Switzerland, with generic mapping requirements in mind. Preliminary experiments suggested that a selection algorithm based on betweenness centrality performed best for this purpose, yet also exposed problems. The main contribution of this paper thus consists of four extensions that address deficiencies of the basic centrality-based algorithm and lead to a significant improvement of the results. The first two extensions improve the formation of strokes concatenating the road segments, which is crucial since strokes provide the foundation upon which the network centrality measure is computed. Thus, the first extension ensures that roundabouts are detected and collapsed, thus avoiding interruptions of strokes by roundabouts, while the second introduces additional semantics in the process of stroke formation, allowing longer and more plausible strokes to built. The third extension detects areas of high road density (i.e., urban areas using density-based clustering and then locally increases the threshold of the centrality measure used to select road segments, such that more thinning takes place in those areas. Finally, since the basic algorithm tends to create dead-ends—which however are not tolerated in small-scale maps—the fourth extension reconnects these dead-ends to the main network, searching for the best path in the main heading of the dead-end.

  11. EDITORIAL: Nanotechnological selection Nanotechnological selection

    Science.gov (United States)

    Demming, Anna

    2013-01-01

    across the channel. The aim of achieving selectivity encompasses a huge range of fields in nanotechnology research, from sensing and medicine to nanoelectronics and self-assembly. As our understanding of how nanosystems behave deepens, so too does the hunger to improve our capabilities, allowing greater precision and control in manipulating these systems. Selectivity is far from trivial when shrinking to systems of nanoscale dimensions, but the range of opportunities it brings just keeps on growing. References [1] Gong X, Li J, Guo C, Xu K and Hui Y 2012 Molecular switch for tuning ions across nanopores by an external electric field Nanotechnology 24 025502 [2] Brannon-Peppas L and Blanchette J O 2004 Nanoparticle and targeted systems for cancer therapy Adv. Drug Deliv. Rev 56 1649-59 [3] Lukianova-Hleb E Y, Hanna E Y, Hafner J H and Lapotko D O 2010 Tunable plasmonic nanobubbles for cell theranostics Nanotechnology 21 085102 [4] Zhang T, Mubeen S, Myung N V and Deshusses M A 2008 Recent progress in carbon nanotube-based gas sensors Nanotechnology 19 332001 [5] Mangu R, Rajaputra S and Singh V P 2011 MWCNT-polymer composites as highly sensitive and selective room temperature gas sensors Nanotechnology 22 215502 [6]Meller A, Nivon L, Brandin E, Golovchenko J and Branton D 2000 Rapid nanopore discrimination between single polynucleotide molecules Proc. Natl Acad. Sci. 97 1079-84 [7] Asghar W, Ilyas A, Deshmukh R R, Sumitsawan S, Timmons R B and Iqbal S M 2011 Pulsed plasma polymerization for controlling shrinkage and surface composition of nanopores Nanotechnology 22 285304

  12. A highly selective and sensitive fluorescent chemosensor and its application for rapid on-site detection of Al3 +

    Science.gov (United States)

    Yue, Xiao-li; Wang, Zhao-qing; Li, Chao-rui; Yang, Zheng-yin

    2018-03-01

    In this paper, a simple naphthalene-based derivative (HL) has been designed and synthesized as a Al3 +-selective fluorescent chemosensor based on the PET mechanism. HL exhibited high selectivity and sensitivity towards Al3 + over other commonly coexisting metal ions in ethanol with a detection limit of 2.72 nM. The 1:1 binding stoichiometry of the complex (HL-Al3 +) was determined from the Job's plot based on fluorescence titrations and the ESI-MS spectrum data. Moreover, the binding site of HL with Al3 + was assured by the 1H NMR titration experiment. The binding constant (Ka) of the complex (HL-Al3 +) was calculated to be 5.06 × 104 M- 1 according to the Benesi-Hildebrand equation. In addition, the recognizing process of HL towards Al3 + was chemically reversible by adding Na2EDTA. Importantly, HL could directly and rapidly detect aluminum ion through the filter paper without resorting to additional instrumental analysis.

  13. Self-Assembly Carbon Nanotubes on Cantilever Biosensor for Sensitivity Enhancement

    Energy Technology Data Exchange (ETDEWEB)

    He, Johnny H [Institute of Microelectronics, 11 Science Park Road, Science Park II, Singapore 117685 (Singapore); Sun Shaoqing [Institute of Microelectronics, 11 Science Park Road, Science Park II, Singapore 117685 (Singapore); Ye Jianshan [Department of Biological Science, National University of Singapore, 14 Science Drive 4, Singapore 117543 (Singapore); Lim, T M [Department of Biological Science, National University of Singapore, 14 Science Drive 4, Singapore 117543 (Singapore)

    2006-04-01

    In recent years, highly sensitive and selective as well as cost-effective sensing and detection of biomolecules (e.g. virus, bacterial, DNA and protein) by MEMS/NEMS (Micro- /Nano Electro- Mechanical-System) structures have attracted extensive attention for its importance in clinical diagnostics, treatment, and various genome projects. Meanwhile, Substantial research efforts have been spent on the improvement of sensitivity of bioMEMS structures. Among a variety of methods that have been investigated, surface modification by nanoparticles (NPs) turns out to be an attractive way, which provides a platform for the enhancement of the sensitivity for biosensor devices. However, conventional applications for surface modification were mostly implemented on microelectrodes. Thus, in this paper, we demonstrate a new approach for surface enhancement on Au-coated silicon microcantilevers in micro-/nano-system. By self-assembly surface binding of multi-walled carbon nanotubes (MWCNTs) on the Au monolayer on top of the Si microcantilever surfaces, much larger surface area could be created for bio-molecular binding (such as antibodies or single DNA strands, which act as probes to capture target molecules). Therefore, this could enable specific interactions and selective binding to target biomolecules with a very low sample size, which greatly increases the sensitivity of detection. It should be noted that functionalization of MWCNTs with terminal carboxylic functionalities (in DCC solution) onto the Au surfaces of Si microchips have been introduced in our study. Further applications of MWCNTs functionalization are worth exploring in biomolecular detection for their exceptional mechanical and unique electronic properties. The successful binding of MWCNTs was testified as shown obviously on AFM image.

  14. A composite material based on nanoparticles of yttrium (III) oxide for the selective and sensitive electrochemical determination of acetaminophen

    Energy Technology Data Exchange (ETDEWEB)

    Baytak, Aysegul Kutluay [Department of Medical Laboratory, Vocational School of Health Services, Harran University, Şanlıurfa 63510 (Turkey); Teker, Tugce; Duzmen, Sehriban [Department of Chemistry, Harran University, Şanlıurfa 63510 (Turkey); Aslanoglu, Mehmet, E-mail: maslanoglu@harran.edu.tr [Department of Chemistry, Harran University, Şanlıurfa 63510 (Turkey)

    2016-09-01

    An electrochemical sensor was prepared by modifying a glassy carbon electrode (GCE) with a composite of yttrium (III) oxide nanoparticles (Y{sub 2}O{sub 3}NPs) and carbon nanotubes (CNTs) for the determination of acetaminophen (ACT). Compared with a bare GCE and CNTs/GCE, the Y{sub 2}O{sub 3}NPs/CNTs/GCE exhibited a well-defined redox couple for ACT and highly enhanced the current response. The separations in the anodic and cathodic peak potentials (ΔE{sub p}) for ACT were 552 mV, 24 mV and 10 mV at ba4re GCE, CNTs/GCE and Y{sub 2}O{sub 3}NPs/CNTs/GCE, respectively. The observation of only 10 mV of ΔE{sub p} for ACT at Y{sub 2}O{sub 3}NPs/CNTs/GCE was a clear indication of a great acceleration of the electrode process compared to bare GCE and GCE modified with CNTs. Also, L-ascorbic acid (L-AA) and L-tyrosine (L-TRY) did not interfere with the selective determination of ACT. Square wave voltammetry (SWV) was performed for the quantification of ACT. A linear plot was obtained for current responses versus the concentrations of ACT over the range from 1.0 × 10{sup −10} to 1.8 × 10{sup −8} M with a detection limit of 3.0 × 10{sup −11} M (based on 3S{sub b}/m). The proposed composite material provided high electrocatalytic activity, improved voltammetric behavior, good selectivity and good reproducibility. The accurate quantification of ACT makes the proposed electrode of great interest for the public health. - Highlights: • A voltammetric sensor based on yttrium oxide was prepared for the detection of ACT. • The proposed electrode has greatly accelerated the voltammetric process of ACT. • A detection limit of 0.03 nM was obtained for ACT. • The proposed electrode exhibited great selectivity for ACT in the presence of L-AA and L-TRY. • The composite material exhibited high sensitivity, good stability and excellent reproducibility.

  15. Improving sensitivity to magnetic fields and electric dipole moments by using measurements of individual magnetic sublevels

    Science.gov (United States)

    Tang, Cheng; Zhang, Teng; Weiss, David S.

    2018-03-01

    We explore ways to use the ability to measure the populations of individual magnetic sublevels to improve the sensitivity of magnetic field measurements and measurements of atomic electric dipole moments (EDMs). When atoms are initialized in the m =0 magnetic sublevel, the shot-noise-limited uncertainty of these measurements is 1 /√{2 F (F +1 ) } smaller than that of a Larmor precession measurement. When the populations in the even (or odd) magnetic sublevels are combined, we show that these measurements are independent of the tensor Stark shift and the second order Zeeman shift. We discuss the complicating effect of a transverse magnetic field and show that when the ratio of the tensor Stark shift to the transverse magnetic field is sufficiently large, an EDM measurement with atoms initialized in the superposition of the stretched states can reach the optimal sensitivity.

  16. Use of immunoblotting assay improves the sensitivity of paracoccidioidomycosis diagnosis

    Directory of Open Access Journals (Sweden)

    D. F. Silva

    2008-01-01

    Full Text Available The purpose of this work was to evaluate two serological assays: double immunodiffusion (DI and immunoblotting (IB in immunodiagnosis of paracoccidioidomycosis (PCM. We evaluated by IB assay 23 sera samples from patients with clinical confirmation of PCM, all of them with negative DI results against culture filtrate from Paracoccidioides brasiliensis isolate 113. For IB, as well as for comparative DI assay, we employed soluble components of the cell wall outer surface (SCCWOS from P. brasiliensis isolate 113 cultivated at 36°C in Fava-Neto's agar medium for 5 and 10 days. Among the 20 sera samples analyzed by DI, 13 (65% were negative and 7 (35% were positive against SCCWOS obtained on the 5th and 10th days. By IB assay, 95.4% and 100% of sera reacted against gp43 and gp70 present in SCCWOS from the 5th day and 95.6% recognized these fractions when evaluated against SCCWOS from the 10th day. Our results demonstrated that the use of an immunoenzymatic assay significantly improves the sensitivity of PCM immunodiagnosis and also suggests that at least two serological tests for antibody detection should be adopted in cases of questionable diagnosis.

  17. Dosage sensitivity shapes the evolution of copy-number varied regions.

    Directory of Open Access Journals (Sweden)

    Benjamin Schuster-Böckler

    2010-03-01

    Full Text Available Dosage sensitivity is an important evolutionary force which impacts on gene dispensability and duplicability. The newly available data on human copy-number variation (CNV allow an analysis of the most recent and ongoing evolution. Provided that heterozygous gene deletions and duplications actually change gene dosage, we expect to observe negative selection against CNVs encompassing dosage sensitive genes. In this study, we make use of several sources of population genetic data to identify selection on structural variations of dosage sensitive genes. We show that CNVs can directly affect expression levels of contained genes. We find that genes encoding members of protein complexes exhibit limited expression variation and overlap significantly with a manually derived set of dosage sensitive genes. We show that complexes and other dosage sensitive genes are underrepresented in CNV regions, with a particular bias against frequent variations and duplications. These results suggest that dosage sensitivity is a significant force of negative selection on regions of copy-number variation.

  18. High-sensitivity high-selectivity detection of CWAs and TICs using tunable laser photoacoustic spectroscopy

    Science.gov (United States)

    Pushkarsky, Michael; Webber, Michael; Patel, C. Kumar N.

    2005-03-01

    We provide a general technique for evaluating the performance of an optical sensor for the detection of chemical warfare agents (CWAs) in realistic environments and present data from a simulation model based on a field deployed discretely tunable 13CO2 laser photoacoustic spectrometer (L-PAS). Results of our calculations show the sensor performance in terms of usable sensor sensitivity as a function of probability of false positives (PFP). The false positives arise from the presence of many other gases in the ambient air that could be interferents. Using the L-PAS as it exists today, we can achieve a detection threshold of about 4 ppb for the CWAs while maintaining a PFP of less than 1:106. Our simulation permits us to vary a number of parameters in the model to provide guidance for performance improvement. We find that by using a larger density of laser lines (such as those obtained through the use of tunable semiconductor lasers), improving the detector noise and maintaining the accuracy of laser frequency determination, optical detection schemes can make possible CWA sensors having sub-ppb detection capability with TIC detection.

  19. Improving the performance of electrochemical microsensors based on enzymes entrapped in a redox hydrogel

    International Nuclear Information System (INIS)

    Mitala, J.J.; Michael, A.C.

    2006-01-01

    Microsensors based on carbon fiber microelectrodes coated with enzyme-entrapping redox hydrogels facilitate the in vivo detection of substances of interest within the central nervous system, including hydrogen peroxide, glucose, choline and glutamate. The hydrogel, formed by cross-linking a redox polymer, entraps the enzymes and mediates electron transfer between the enzymes and the electrode. It is important that the enzymes are entrapped in their enzymatically active state. Should entrapment cause enzyme denaturation, the sensitivity and the selectivity of the sensor may be compromised. Synthesis of the redox polymer according to published procedures may yield a product that precipitates when added to aqueous enzyme solutions. Casting hydrogels from solutions that contain the precipitate produces microsensors with low sensitivity and selectivity, suggesting that the precipitation disrupts the structure of the enzymes. Herein, we show that a surfactant, sodium dodecyl sulfate (SDS), can prevent the precipitation and improve the sensitivity and selectivity of the sensors

  20. In vitro sensitivity of Hungarian Actinobaculum suis strains to selected antimicrobials.

    Science.gov (United States)

    Biksi, I; Major, Andrea; Fodor, L; Szenci, O; Vetési, F

    2003-01-01

    In vitro antimicrobial sensitivity of 12 Hungarian isolates and the type strain ATCC 33144 of Actinobaculum suis to different antimicrobial compounds was determined both by the agar dilution and by the disc diffusion method. By agar dilution, MIC50 values in the range of 0.05-3.125 micrograms/ml were determined for penicillin, ampicillin, ceftiofur, doxycycline, tylosin, pleuromutilins, chloramphenicol, florfenicol, enrofloxacin and lincomycin. The MIC50 value of oxytetracycline and spectinomycin was 6.25 and 12.5 micrograms/ml, respectively. For ofloxacin, flumequine, neomycin, streptomycin, gentamicin, nalidixic acid, nitrofurantoin and sulphamethoxazole + trimethoprim MIC50 values were in the range of 25-100 micrograms/ml. With the disc diffusion method, all strains were sensitive to penicillin, cephalosporins examined, chloramphenicol and florfenicol, tetracyclines examined, pleuromutilins, lincomycin and tylosin. Variable sensitivity was observed for fluoroquinolones (flumequine, enrofloxacin, ofloxacin), most of the strains were susceptible to marbofloxacin. Almost all strains were resistant to aminoglycosides but most of them were sensitive to spectinomycin. A strong correlation was determined for disc diffusion and MIC results (Spearman's rho 0.789, p < 0001). MIC values of the type strain and MIC50 values of other tested strains did not differ significantly. Few strains showed a partially distinct resistance pattern for erythromycin, lincomycin and ampicillin in both methods.

  1. Analysis of Power Network for Line Reactance Variation to Improve Total Transmission Capacity

    Directory of Open Access Journals (Sweden)

    Ikram Ullah

    2016-11-01

    Full Text Available The increasing growth in power demand and the penetration of renewable distributed generations in competitive electricity market demands large and flexible capacity from the transmission grid to reduce transmission bottlenecks. The bottlenecks cause transmission congestion, reliability problems, restrict competition, and limit the maximum dispatch of low cost generations in the network. The electricity system requires efficient utilization of the current transmission capability to improve the Available Transfer Capability (ATC. To improve the ATC, power flow among the lines can be managed by using Flexible AC Transmission System (FACTS devices as power flow controllers, which alter the parameters of power lines. It is important to place FACTS devices on suitable lines to vary the reactance for improving Total Transmission Capacity (TTC of the network and provide flexibility in the power flow. In this paper a transmission network is analyzed based on line parameters variation to improve TTC of the interconnected system. Lines are selected for placing FACTS devices based on real power flow Performance Index (PI sensitivity factors. TTC is computed using the Repeated Power Flow (RPF method using the constraints of lines thermal limits, bus voltage limits and generator limits. The reactance of suitable lines, selected on the basis of PI sensitivity factors are changed to divert the power flow to other lines with enough transfer capacity available. The improvement of TTC using line reactance variation is demonstrated with three IEEE test systems with multi-area networks. The results show the variation of the selected lines’ reactance in improving TTC for all the test networks with defined contingency cases.

  2. Improved time series prediction with a new method for selection of model parameters

    International Nuclear Information System (INIS)

    Jade, A M; Jayaraman, V K; Kulkarni, B D

    2006-01-01

    A new method for model selection in prediction of time series is proposed. Apart from the conventional criterion of minimizing RMS error, the method also minimizes the error on the distribution of singularities, evaluated through the local Hoelder estimates and its probability density spectrum. Predictions of two simulated and one real time series have been done using kernel principal component regression (KPCR) and model parameters of KPCR have been selected employing the proposed as well as the conventional method. Results obtained demonstrate that the proposed method takes into account the sharp changes in a time series and improves the generalization capability of the KPCR model for better prediction of the unseen test data. (letter to the editor)

  3. Gentle cleansing and moisturizing for patients with atopic dermatitis and sensitive skin.

    Science.gov (United States)

    Cheong, Wai Kwong

    2009-01-01

    Atopic dermatitis is a common condition characterized by pruritus, inflammation, and dryness of the skin. Inflammation disrupts the barrier function of the stratum corneum, predisposing the skin to be dry, and increases susceptibility to irritants and secondary bacterial infection. Sensitive skin is common, reported by 40-50% of women and 30% of men in the US, Europe, and Japan. Basic requirements in managing eczema and sensitive skin include effective cleansers that do not compromise skin barrier integrity, alleviation of skin dryness, and restoration of skin barrier function through the use of therapeutic moisturizers. The selection of a skin cleanser is therefore an important part of managing these conditions. Studies have reported clinical improvement with the use of soap-free cleansers in combination with topical treatments. While topical corticosteroids and immunosuppressive agents are mainstays of treatment for atopic dermatitis, therapeutic moisturizers are important adjuncts. Moisturizers improve skin hydration, reduce susceptibility to irritation, restore the integrity of the stratum corneum, and enhance the efficacy of topical corticosteroids.

  4. In Vitro Selection of Single-Stranded DNA Molecular Recognition Elements against S. aureus Alpha Toxin and Sensitive Detection in Human Serum

    Directory of Open Access Journals (Sweden)

    Ka L. Hong

    2015-01-01

    Full Text Available Alpha toxin is one of the major virulence factors secreted by Staphylococcus aureus, a bacterium that is responsible for a wide variety of infections in both community and hospital settings. Due to the prevalence of S. aureus related infections and the emergence of methicillin-resistant S. aureus, rapid and accurate diagnosis of S. aureus infections is crucial in benefiting patient health outcomes. In this study, a rigorous Systematic Evolution of Ligands by Exponential Enrichment (SELEX variant previously developed by our laboratory was utilized to select a single-stranded DNA molecular recognition element (MRE targeting alpha toxin with high affinity and specificity. At the end of the 12-round selection, the selected MRE had an equilibrium dissociation constant (Kd of 93.7 ± 7.0 nM. Additionally, a modified sandwich enzyme-linked immunosorbent assay (ELISA was developed by using the selected ssDNA MRE as the toxin-capturing element and a sensitive detection of 200 nM alpha toxin in undiluted human serum samples was achieved.

  5. Training self-assessment and task-selection skills: A cognitive approach to improving self-regulated learning

    NARCIS (Netherlands)

    Kostons, Danny; Van Gog, Tamara; Paas, Fred

    2012-01-01

    Kostons, D., Van Gog, T., & Paas, F. (2012). Training self-assessment and task-selection skills: A cognitive approach to improving self-regulated learning. Learning and Instruction, 22(2), 121-132. doi:10.1016/j.learninstruc.2011.08.004

  6. Highly selective and sensitive phosphate anion sensors based on AlGaN/GaN high electron mobility transistors functionalized by ion imprinted polymer.

    Science.gov (United States)

    Jia, Xiuling; Chen, Dunjun; Bin, Liu; Lu, Hai; Zhang, Rong; Zheng, Youdou

    2016-06-09

    A novel ion-imprinted electrochemical sensor based on AlGaN/GaN high electron mobility transistors (HEMTs) was developed to detect trace amounts of phosphate anion. This sensor combined the advantages of the ion sensitivity of AlGaN/GaN HEMTs and specific recognition of ion imprinted polymers. The current response showed that the fabricated sensor is highly sensitive and selective to phosphate anions. The current change exhibited approximate linear dependence for phosphate concentration from 0.02 mg L(-1) to 2 mg L(-1), the sensitivity and detection limit of the sensor is 3.191 μA/mg L(-1) and 1.97 μg L(-1), respectively. The results indicated that this AlGaN/GaN HEMT-based electrochemical sensor has the potential applications on phosphate anion detection.

  7. Improvement of ionic conductivity and performance of quasi-solid-state dye sensitized solar cell using PEO/PMMA gel electrolyte

    International Nuclear Information System (INIS)

    Aram, E.; Ehsani, M.; Khonakdar, H.A.

    2015-01-01

    Graphical abstract: Reduced interfacial resistance of a quasi-solid-state dye sensitized solar cell with PEO/PMMA blend gel electrolytes. - Highlights: • A new polymer gel electrolyte containing PEO/PMMA was developed for DSSCs. • Optimization of polymer gel electrolyte was done for dye sensitized solar cell. • The best ionic conductivity was found in PEO/PMMA blend with 10/90 w/w composition. • The DSSC with the PEO/PMMA based electrolyte showed good photovoltaic performance. • Significant stability improvement for quasi-solid state DSSC was obtained. - Abstract: Polymer blend gel electrolytes based on polyethylene oxide (PEO) and poly(methyl methacrylate) (PMMA) as host polymers with various weight ratios, LiI/I 2 as redox couple in electrolyte and 4-tert-butyl pyridine as additive were prepared by solution method. The introduction of PMMA in the PEO gel electrolyte reduced the degree of crystallinity of PEO, which was confirmed by differential scanning calorimetry (DSC). Complexation and ionic conductivity as a function of temperature were investigated with Fourier transform infrared and ionic conductometry, respectively. A good correlation was found between the degree of crystallinity and ionic conductivity. The reduction in crystallinity, governed by blending ratio, led to improvement of ionic conductivity. The best ionic conductivity was attained in PEO/PMMA blend with 10/90 w/w composition. The performance of a quasi-solid-state dye sensitized solar cell using the optimized polymer gel electrolyte was investigated. The optimized system of high ionic conductivity of 7 mS cm −1 , with fill factor of 0.59, short-circuit density of 11.11 mA cm −2 , open-circuit voltage of 0.75 V and the conversion efficiency of 4.9% under air mass 1.5 irradiation (100 mW cm −2 ) was obtained. The long-term stability of the dye-sensitized solar cell (DSSC) during 600 h was improved by using PEO/PMMA gel electrolyte relative to a liquid type electrolyte

  8. Improvement of ionic conductivity and performance of quasi-solid-state dye sensitized solar cell using PEO/PMMA gel electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Aram, E. [Iran Polymer and Petrochemical Institute, 14965/115 Tehran (Iran, Islamic Republic of); Ehsani, M., E-mail: m.ehsani@ippi.ac.ir [Iran Polymer and Petrochemical Institute, 14965/115 Tehran (Iran, Islamic Republic of); Khonakdar, H.A. [Iran Polymer and Petrochemical Institute, 14965/115 Tehran (Iran, Islamic Republic of); Leibniz Institute of Polymer Research, D-01067 Dresden (Germany)

    2015-09-10

    Graphical abstract: Reduced interfacial resistance of a quasi-solid-state dye sensitized solar cell with PEO/PMMA blend gel electrolytes. - Highlights: • A new polymer gel electrolyte containing PEO/PMMA was developed for DSSCs. • Optimization of polymer gel electrolyte was done for dye sensitized solar cell. • The best ionic conductivity was found in PEO/PMMA blend with 10/90 w/w composition. • The DSSC with the PEO/PMMA based electrolyte showed good photovoltaic performance. • Significant stability improvement for quasi-solid state DSSC was obtained. - Abstract: Polymer blend gel electrolytes based on polyethylene oxide (PEO) and poly(methyl methacrylate) (PMMA) as host polymers with various weight ratios, LiI/I{sub 2} as redox couple in electrolyte and 4-tert-butyl pyridine as additive were prepared by solution method. The introduction of PMMA in the PEO gel electrolyte reduced the degree of crystallinity of PEO, which was confirmed by differential scanning calorimetry (DSC). Complexation and ionic conductivity as a function of temperature were investigated with Fourier transform infrared and ionic conductometry, respectively. A good correlation was found between the degree of crystallinity and ionic conductivity. The reduction in crystallinity, governed by blending ratio, led to improvement of ionic conductivity. The best ionic conductivity was attained in PEO/PMMA blend with 10/90 w/w composition. The performance of a quasi-solid-state dye sensitized solar cell using the optimized polymer gel electrolyte was investigated. The optimized system of high ionic conductivity of 7 mS cm{sup −1}, with fill factor of 0.59, short-circuit density of 11.11 mA cm{sup −2}, open-circuit voltage of 0.75 V and the conversion efficiency of 4.9% under air mass 1.5 irradiation (100 mW cm{sup −2}) was obtained. The long-term stability of the dye-sensitized solar cell (DSSC) during 600 h was improved by using PEO/PMMA gel electrolyte relative to a liquid type

  9. A novel immunochromatographic electrochemical biosensor for highly sensitive and selective detection of trichloropyridinol, a biomarker of exposure to chlorpyrifos.

    Science.gov (United States)

    Wang, Limin; Lu, Donglai; Wang, Jun; Du, Dan; Zou, Zhexiang; Wang, Hua; Smith, Jordan N; Timchalk, Charles; Liu, Fengquan; Lin, Yuehe

    2011-02-15

    We present a novel portable immunochromatographic electrochemical biosensor (IEB) for simple, rapid, and sensitive biomonitoring of trichloropyridinol (TCP), a metabolite biomarker of exposure to organophosphorus insecticides. Our new approach takes the advantage of immunochromatographic test strip for a rapid competitive immunoreaction and a disposable screen-printed carbon electrode for a rapid and sensitive electrochemical analysis of captured HRP labeling. Several key experimental parameters (e.g. immunoreaction time, the amount of HRP labeled TCP, concentration of the substrate for electrochemical measurements, and the blocking agents for the nitrocellulose membrane) were optimized to achieve a high sensitivity, selectivity and stability. Under optimal conditions, the IEB has demonstrated a wide linear range (0.1-100 ng/ml) with a detection limit as low as 0.1 ng/ml TCP. Furthermore, the IEB has been successfully applied for biomonitoring of TCP in the rat plasma samples with in vivo exposure to organophosphorus insecticides like Chlorpyrifos-oxon (CPF-oxon). The IEB thus opens up new pathways for designing a simple, rapid, clinically accurate, and quantitative tool for TCP detection, as well as holds a great promise for in-field screening of metabolite biomarkers, e.g., TCP, for humans exposed to organophosphorus insecticides. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. Sensitivity analysis of infectious disease models: methods, advances and their application

    Science.gov (United States)

    Wu, Jianyong; Dhingra, Radhika; Gambhir, Manoj; Remais, Justin V.

    2013-01-01

    Sensitivity analysis (SA) can aid in identifying influential model parameters and optimizing model structure, yet infectious disease modelling has yet to adopt advanced SA techniques that are capable of providing considerable insights over traditional methods. We investigate five global SA methods—scatter plots, the Morris and Sobol’ methods, Latin hypercube sampling-partial rank correlation coefficient and the sensitivity heat map method—and detail their relative merits and pitfalls when applied to a microparasite (cholera) and macroparasite (schistosomaisis) transmission model. The methods investigated yielded similar results with respect to identifying influential parameters, but offered specific insights that vary by method. The classical methods differed in their ability to provide information on the quantitative relationship between parameters and model output, particularly over time. The heat map approach provides information about the group sensitivity of all model state variables, and the parameter sensitivity spectrum obtained using this method reveals the sensitivity of all state variables to each parameter over the course of the simulation period, especially valuable for expressing the dynamic sensitivity of a microparasite epidemic model to its parameters. A summary comparison is presented to aid infectious disease modellers in selecting appropriate methods, with the goal of improving model performance and design. PMID:23864497

  11. Selection of body sway parameters according to their sensitivity and repeatability

    Directory of Open Access Journals (Sweden)

    Nejc Sarabon

    2010-03-01

    Full Text Available For the precise evaluation of body balance, static type of tests performed on a force plate are the most commonly used ones. In these tests, body sway characteristics are analyzed based on the model of inverted pendulum and looking at the center of pressure (COP movement in time. Human body engages different strategies to compensate for balance perturbations. For this reason, there is a need to identify parameters which are sensitive to specific balance changes and which enable us to identify balance sub-components. The aim of our study was to investigate intra-visit repeatability and sensibility of the 40 different body sway parameters. Twenty-nine subjects participated in the study. They performed three different balancing tasks of different levels of difficulty, three repetitions each. The hip-width parallel stance and the single leg stance, both with open eyes, were used as ways to compare different balance intensities due to biomechanical changes. Additionally, deprivation of vision was used in the third balance task to study sensitivity to sensory system changes. As shown by intraclass correlation coefficient (ICC, repeatability of cumulative parameters such as COP, maximal amplitude and frequency showed excellent repeatability (ICC>0,85. Other parameters describing sub-dynamics through single repetition proved to have unsatisfying repeatability. Parameters most sensitive to increased intensity of balancing tasks were common COP, COP in medio-lateral and in antero-posterior direction, and maximal amplitues in the same directions. Frequency of oscilations has proved to be sensitive only to deprivation of vision. As shown in our study, cumulative parameters describing the path which the center of pressure makes proved to be the most repeatable and sensitive to detect different increases of balancing tasks enabling future use in balance studies and in clinical practice.

  12. Improved sensitivity and specificity for resting state and task fMRI with multiband multi-echo EPI compared to multi-echo EPI at 7T.

    NARCIS (Netherlands)

    Boyacioglu, R.; Schulz, J.; Koopmans, P.J.; Barth, M.; Norris, David Gordon

    2015-01-01

    A multiband multi-echo (MBME) sequence is implemented and compared to a matched standard multi-echo (ME) protocol to investigate the potential improvement in sensitivity and spatial specificity at 7 T for resting state and task fMRI. ME acquisition is attractive because BOLD sensitivity is less

  13. High blood pressure and visual sensitivity

    Science.gov (United States)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  14. Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

    Science.gov (United States)

    Sato, K.; Kobayashi, Y.

    2015-05-01

    Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed.

  15. Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

    International Nuclear Information System (INIS)

    Sato, K.; Kobayashi, Y.

    2015-01-01

    Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed

  16. [Application of a continual improvement approach to selecting diagnostic markers for acute pancreatitis in an emergency department].

    Science.gov (United States)

    Salinas, María; Flores, Emilio; López-Garrigós, Maite; Díaz, Elena; Esteban, Patricia; Leiva-Salinas, Carlos

    2017-01-01

    To apply a continual improvement model to develop an algorithm for ordering laboratory tests to diagnose acute pancreatitis in a hospital emergency department. Quasi-experimental study using the continual improvement model (plan, do, check, adjust cycles) in 2 consecutive phases in emergency patients: amylase and lipase results were used to diagnose acute pancreatitis in the first phase; in the second, only lipase level was first determined; amylase testing was then ordered only if the lipase level fell within a certain range. We collected demographic data, number amylase and lipase tests ordered and the findings, final diagnosis, and the results of a questionnaire to evaluate satisfaction with emergency care. The first phase included 517 patients, of whom 20 had acute pancreatitis. For amylase testing sensitivity was 0.70; specificity, 0.85; positive predictive value (PPV), 17; and negative predictive value (NPV), 0.31. For lipase testing these values were sensitivity, 0.85; specificity, 0.96; PPV, 21, and NPV, 0.16. When both tests were done, sensitivity was 0.85; specificity 0.99; PPV, 85; and NPV, 0.15. The second phase included data for 4815 patients, 118 of whom had acute pancreatitis. The measures of diagnostic yield for the new algorithm were sensitivity, 0.92; specificity, 0.98; PPV, 46; and NPV, 0.08]. This study demonstrates a process for developing a protocol to guide laboratory testing in acute pancreatitis in the hospital emergency department. The proposed sequence of testing for pancreatic enzyme levels can be effective for diagnosing acute pancreatitis in patients with abdominal pain.

  17. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  18. Enhancement of dye-sensitized solar cells performances by improving electron density in conduction band of nanostructure TiO2 electrode with using a metalloporphyrin as additional dye

    International Nuclear Information System (INIS)

    Mojiri-Foroushani, M.; Dehghani, H.; Salehi-Vanani, N.

    2013-01-01

    Highlights: ► N719 and ZnTCPP dyes were used in a sequential adsorption process. ► By using two dyes, improved the performance of the cell. ► Density of electrons in the conduction band of TiO 2 electrodes improved. -- Abstract: A zinc(II)-porphyrin dye with four carboxyphenyl moiety of ancillary (ZnTCPP) was studied as a sensitizer in combination with a ruthenium complex (N719) in co-sensitized solar cells. The high molar extinction coefficient (ε) of porphyrin dyes leads to high light absorption in the dye-sensitized TiO 2 electrode. In spite of the high ε of porphyrin dyes, they usually have a narrow absorption band and also to suffer from dye aggregation due to their planar structural nature. This causes lower efficiencies of the DSSCs for the porphyrins than the ruthenium complexes. Co-sensitization of two or more dyes with complementary absorption spectra on TiO 2 film is an important method to further enhance the IPCE response and energy conversion efficiency of dye-sensitized solar cells. Interestingly, when the ZnTCPP electrode was used to assemble a co-sensitized solar cell by additional adsorption of N719 dye, the efficiency improved to 6.35% (in comparison to N719 that the efficiency was 4.74%). The results indicated that the co-sensitized device shows enhancements of photovoltaic performance not only in short-circuit current density (J SC ) but also in open-circuit voltage (V OC ). In the present study we have been shown that co-sensitization of a zinc(II)-porphyrin with N719 dye changes the energy levels of the TiO 2 electrode and in result produces further improvement for its device performance

  19. Improving the Bandwidth Selection in Kernel Equating

    Science.gov (United States)

    Andersson, Björn; von Davier, Alina A.

    2014-01-01

    We investigate the current bandwidth selection methods in kernel equating and propose a method based on Silverman's rule of thumb for selecting the bandwidth parameters. In kernel equating, the bandwidth parameters have previously been obtained by minimizing a penalty function. This minimization process has been criticized by practitioners…

  20. Sensitivity-Uncertainty Techniques for Nuclear Criticality Safety

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Forrest B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rising, Michael Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Alwin, Jennifer Louise [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-07

    The sensitivity and uncertainty analysis course will introduce students to keff sensitivity data, cross-section uncertainty data, how keff sensitivity data and keff uncertainty data are generated and how they can be used. Discussion will include how sensitivity/uncertainty data can be used to select applicable critical experiments, to quantify a defensible margin to cover validation gaps and weaknesses, and in development of upper subcritical limits.

  1. Highly Sensitive and Selective In-Situ SERS Detection of Pb(2+), Hg(2+), and Cd(2+) Using Nanoporous Membrane Functionalized with CNTs.

    Science.gov (United States)

    Shaban, Mohamed; Galaly, A R

    2016-05-04

    Porous Anodic Alumina (PAA) membrane was functionalized with CoFe2O4 nanoparticles and used as a substrate for the growing of very long helical-structured Carbon Nanotubes (CNTs) with a diameter less than 20 nm. The structures and morphologies of the fabricated nanostructures were characterized by field emission- scanning electron microscopy (FE-SEM), energy dispersive X-ray (EDX), and Raman spectroscopy. By uploading the CNTs on PAA, the characteristic Raman peaks of CNTs and PAA showed 4 and 3 times enhancement, respectively, which leads to more sensitive Surface-Enhanced Raman Spectroscopy (SERS) substrates. For comparison, PAA and CNTs/PAA arrays were used as SERS substrates for the detection of Hg(2+), Cd(2+), and Pb(2+). The proposed sensor demonstrated high sensitivity and selectivity between these heavy metal ions. CNTs/PAA sensor showed excellent selectivity toward Pb(2+) over other metal ions, where the enhancement factor is decreased from ~17 for Pb(2+) to ~12 for Hg(2+) and to ~4 for Cd(2+). Therefore, the proposed CNTs/PAA sensor can be used as a powerful tool for the determination of heavy metal ions in aqueous solutions.

  2. Highly Sensitive and Selective In-Situ SERS Detection of Pb2+, Hg2+, and Cd2+ Using Nanoporous Membrane Functionalized with CNTs

    Science.gov (United States)

    Shaban, Mohamed; Galaly, A. R.

    2016-01-01

    Porous Anodic Alumina (PAA) membrane was functionalized with CoFe2O4 nanoparticles and used as a substrate for the growing of very long helical-structured Carbon Nanotubes (CNTs) with a diameter less than 20 nm. The structures and morphologies of the fabricated nanostructures were characterized by field emission- scanning electron microscopy (FE-SEM), energy dispersive X-ray (EDX), and Raman spectroscopy. By uploading the CNTs on PAA, the characteristic Raman peaks of CNTs and PAA showed 4 and 3 times enhancement, respectively, which leads to more sensitive Surface-Enhanced Raman Spectroscopy (SERS) substrates. For comparison, PAA and CNTs/PAA arrays were used as SERS substrates for the detection of Hg2+, Cd2+, and Pb2+. The proposed sensor demonstrated high sensitivity and selectivity between these heavy metal ions. CNTs/PAA sensor showed excellent selectivity toward Pb2+ over other metal ions, where the enhancement factor is decreased from ~17 for Pb2+ to ~12 for Hg2+ and to ~4 for Cd2+. Therefore, the proposed CNTs/PAA sensor can be used as a powerful tool for the determination of heavy metal ions in aqueous solutions. PMID:27143512

  3. Metformin improves glucose effectiveness, not insulin sensitivity: predicting treatment response in women with polycystic ovary syndrome in an open-label, interventional study.

    Science.gov (United States)

    Pau, Cindy T; Keefe, Candace; Duran, Jessica; Welt, Corrine K

    2014-05-01

    Although metformin is widely used to improve insulin resistance in women with polycystic ovary syndrome (PCOS), its mechanism of action is complex, with inconsistent effects on insulin sensitivity and variability in treatment response. The aim of the study was to delineate the effect of metformin on glucose and insulin parameters, determine additional treatment outcomes, and predict patients with PCOS who will respond to treatment. We conducted an open-label, interventional study at an academic medical center. Women with PCOS (n = 36) diagnosed by the National Institutes of Health criteria participated in the study. Subjects underwent fasting blood sampling, an IV glucose tolerance test, dual-energy x-ray absorptiometry scan, transvaginal ultrasound, and measurement of human chorionic gonadotropin-stimulated androgen levels before and after 12 weeks of treatment with metformin extended release 1500 mg/d. Interval visits were performed to monitor anthropometric measurements and menstrual cycle parameters. Changes in glucose and insulin parameters, androgen levels, anthropometric measurements, and ovulatory menstrual cycles were evaluated. Insulin sensitivity did not change despite weight loss. Glucose effectiveness (P = .002) and the acute insulin response to glucose (P = .002) increased, and basal glucose levels (P = .001) decreased after metformin treatment. T levels also decreased. Women with improved ovulatory function (61%) had lower baseline T levels and lower baseline and stimulated T and androstenedione levels after metformin treatment (all P effectiveness and insulin sensitivity, metformin does not improve insulin sensitivity in women with PCOS but does improve glucose effectiveness. The improvement in glucose effectiveness may be partially mediated by decreased glucose levels. T levels also decreased with metformin treatment. Ovulation during metformin treatment was associated with lower baseline T levels and greater T and androstenedione decreases during

  4. A hybrid molecularly imprinted polymer coated quantum dot nanocomposite optosensor for highly sensitive and selective determination of salbutamol in animal feeds and meat samples.

    Science.gov (United States)

    Raksawong, Phannika; Chullasat, Kochaporn; Nurerk, Piyaluk; Kanatharana, Proespichaya; Davis, Frank; Bunkoed, Opas

    2017-08-01

    A hybrid molecularly imprinted polymer (MIP)-coated quantum dot (QD) nanocomposite was synthesized and applied as a fluorescence probe for the highly sensitive and selective determination of salbutamol. The hybrid MIP-coated QD nanocomposite was synthesized via a copolymerization process in the presence of thioglycolic acid capped CdTe QDs with salbutamol as a template, 3-aminopropyltriethoxysilane as the functional monomer, and tetraethyl orthosilicate as a cross-linker. The optimum molar ratio of template, monomer, and cross-linker was 1:6:20. The fluorescence intensity of the hybrid MIP-coated QDs was efficiently quenched after salbutamol rebound to the recognition sites, as a result of charge transfer from QDs to salbutamol. The synthesized hybrid MIP-coated QD nanocomposite showed high sensitivity and good selectivity toward salbutamol. Under the optimal recognition conditions, the fluorescence intensity was quenched linearly with increasing concentration of salbutamol in the range from 0.10 to 25.0 μg L -1 , with a detection limit of 0.034 μg L -1 . The hybrid optosensor developed was successfully applied in the determination of salbutamol in animal feeds and meat samples. Satisfactory recoveries were obtained in the range from 85% to 98%, with a standard deviation of less than 8%. Furthermore, the accuracy of the hybrid MIP-coated QD nanocomposite was investigated by comparison with a conventional high-performance liquid chromatography method, with the results obtained with two methods agreeing well with each other. The advantages of this sensing method are simplicity, rapidity, cost-effectiveness, high sensitivity, and good selectivity. Graphical Abstract The synthesis of hybrid MIP-coated QDs nanocomposite.

  5. Highly sensitive piezo-resistive graphite nanoplatelet-carbon nanotube hybrids/polydimethylsilicone composites with improved conductive network construction.

    Science.gov (United States)

    Zhao, Hang; Bai, Jinbo

    2015-05-13

    The constructions of internal conductive network are dependent on microstructures of conductive fillers, determining various electrical performances of composites. Here, we present the advanced graphite nanoplatelet-carbon nanotube hybrids/polydimethylsilicone (GCHs/PDMS) composites with high piezo-resistive performance. GCH particles were synthesized by the catalyst chemical vapor deposition approach. The synthesized GCHs can be well dispersed in the matrix through the mechanical blending process. Due to the exfoliated GNP and aligned CNTs coupling structure, the flexible composite shows an ultralow percolation threshold (0.64 vol %) and high piezo-resistive sensitivity (gauge factor ∼ 10(3) and pressure sensitivity ∼ 0.6 kPa(-1)). Slight motions of finger can be detected and distinguished accurately using the composite film as a typical wearable sensor. These results indicate that designing the internal conductive network could be a reasonable strategy to improve the piezo-resistive performance of composites.

  6. Improved sensitivity testing of explosives using transformed Up-Down methods

    International Nuclear Information System (INIS)

    Brown, Geoffrey W

    2014-01-01

    Sensitivity tests provide data that help establish guidelines for the safe handling of explosives. Any sensitivity test is based on assumptions to simplify the method or reduce the number of individual sample evaluations. Two common assumptions that are not typically checked after testing are 1) explosive response follows a normal distribution as a function of the applied stimulus levels and 2) the chosen test level spacing is close to the standard deviation of the explosive response function (for Bruceton Up-Down testing for example). These assumptions and other limitations of traditional explosive sensitivity testing can be addressed using Transformed Up-Down (TUD) test methods. TUD methods have been developed extensively for psychometric testing over the past 50 years and generally use multiple tests at a given level to determine how to adjust the applied stimulus. In the context of explosive sensitivity we can use TUD methods that concentrate testing around useful probability levels. Here, these methods are explained and compared to Bruceton Up-Down testing using computer simulation. The results show that the TUD methods are more useful for many cases but that they do require more tests as a consequence. For non-normal distributions, however, the TUD methods may be the only accurate assessment method.

  7. Ionizing radiation method for forming acrylic pressure sensitive adhesives and coated substrates

    International Nuclear Information System (INIS)

    Dowbenko, R.; Christenson, R.M.

    1975-01-01

    Pressure-sensitive adhesive having improved adhesive properties are formed by subjecting a mixture comprising a monomer selected from the group consisting of alkyl acrylates, hydroxyalkyl acrylates, alkoxyalkyl acrylates, cyanoalkyl acrylates, alkyl methacrylates, hydroxyalkyl methacrylates, alkoxyalkyl methacrylates, cyanoalkyl methacrylates, N-alkoxymethylacrylamides, and N-alkoxymethylmethacrylamides, and a homopolymer or copolymer selected from the group consisting of polymers of alkyl acrylates, hydroxyalkyl acrylates, alkoxyalkyl acrylates, cyanoalkyl acrylates, alkyl methacrylates, hydroxyalkyl methacrylates, alkoxyalkyl methacrylates, cyanoalkyl methacrylates, acrylamide, methacrylamide, N-(substituted alkyl) acrylamides, N-(substituted alkyl) methacrylamides, alkyl acrylamides, alkyl methacrylamides, and N-alkoxymethylacrylamides and N-alkoxymethylmethacrylamides to ionizing irradiation. The adhesive material finds utility as binding resins in laminates, coatings on substrates, and as film adhesives. (U.S.)

  8. Characteristics of the telescope for high energy gamma-ray astronomy selected for definition studies on the Gamma Ray Observatory

    Science.gov (United States)

    Hughes, E. B.; Hofstadter, R.; Rolfe, J.; Johansson, A.; Bertsch, D. L.; Cruickshank, W. J.; Ehrmann, C. H.; Fichtel, C. E.; Hartman, R. C.; Kniffen, D. A.

    1980-01-01

    The high energy gamma-ray telescope selected for definition studies on the Gamma Ray Observatory provides a substantial improvement in observational capability over earlier instruments. It will have about 20 times more sensitivity, cover a much broader energy range, have considerably better energy resolution and provide a significantly improved angular resolution. The design and performance are described.

  9. Integrated ion imprinted polymers-paper composites for selective and sensitive detection of Cd(II) ions

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Kai [State Key Laboratory of Environment Health - Incubation, Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health Wuhan, Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Hubei, 430030, Wuhan (China); Chen, Ying [Hubei Center for Disease Control and Prevention, No. 6 ZhuoDao Quan North Road, 430079, Wuhan (China); Zhou, Feng [State Key Laboratory of Environment Health - Incubation, Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health Wuhan, Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Hubei, 430030, Wuhan (China); Zhao, Xiaoya [Hubei Entry-Exit Inspection and Quarantine Bureau of PRC, No.588 Qingtaidadao Road, Hubei, 430022, Wuhan (China); Liu, Jiafa [Hubei Center for Disease Control and Prevention, No. 6 ZhuoDao Quan North Road, 430079, Wuhan (China); Mei, Surong; Zhou, Yikai [State Key Laboratory of Environment Health - Incubation, Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health Wuhan, Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Hubei, 430030, Wuhan (China); Jing, Tao, E-mail: jingtao@hust.edu.cn [State Key Laboratory of Environment Health - Incubation, Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health Wuhan, Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, #13 Hangkong Road, Hubei, 430030, Wuhan (China)

    2017-07-05

    Highlights: • IIPs are first grafted on the low-cost A4 print paper to develop an integrated paper-based device. • As an imprinted composite, the adsorption capacity is 155.2 mg g{sup –1} and the imprinted factor is more than 3.0. • As an analytical method, the limit of detection is 0.4 ng mL{sup –1}. • Based on the water quality standards, it could be used to determine Cd(II) ions in drinking water. - Abstract: Paper-based sensor is a new alternative technology to develop a portable, low-cost, and rapid analysis system in environmental chemistry. In this study, ion imprinted polymers (IIPs) using cadmium ions as the template were directly grafted on the surface of low-cost print paper based on the reversible addition-fragmentation chain transfer polymerization. It can be applied as a recognition element to selectively capture the target ions in the complex samples. The maximum adsorption capacity of IIPs composites was 155.2 mg g{sup –1} and the imprinted factor was more than 3.0. Then, IIPs-paper platform could be also applied as a detection element for highly selective and sensitive detection of Cd(II) ions without complex sample pretreatment and expensive instrument, due to the selective recognition, formation of dithizone-cadmium complexes and light transmission ability. Under the optimized condition, the linear range was changed from 1 to 100 ng mL{sup –1} and the limit of detection was 0.4 ng mL{sup –1}. The results were in good agreement with the classic ICP-MS method. Furthermore, the proposed method can also be developed for detection of other heavy metals by designing of new IIPs.

  10. Proof of cannabis administration by sensitive detection of 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid in hair using selective methylation and application of liquid chromatography- tandem and multistage mass spectrometry.

    Science.gov (United States)

    Thieme, Detlef; Sachs, Hans; Uhl, Michael

    2014-01-01

    The identification of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH) in hair represents an exceptional forensic analytical challenge due to low target concentrations in a complex matrix. Several dedicated techniques [gas chromatography-negative chemical ionization-tandem mass spectrometry (GC-NCI-MS/MS) or GC-GC-MS couplings] were specifically introduced into forensic toxicology aiming to a selective and sensitive identification of THCCOOH in hair. The combination of liquid-chromatography (LC) and MS/MS gained an outstanding relevance in forensic toxicology (including the detection of cannabinoids). However, its application to hair matrix is characterized by a lack of specificity which is due to the unspecific decarboxylation as most abundant fragmentation reaction. Therefore, various chemical modifications of the carboxyl and/or phenolic hydroxyl groups were examined to improve the selectivity. The selective methylation of the 9-carboxyl-group proved to be the most efficient derivatization procedure. Hair extracts were redissolved in acetonitrile and after addition of few milligrams of solid sodium carbonate derivatized with 25 μL methyl iodide. The resulting THC-9-carboxymethylester was separated by conventional reverse phase LC and selectively detected using negative electrospray ionization by recording the fragmentation reactions 357➔325 and 357➔297. Resulting limits of quantification were below 100 fg/mg. A further significant improvement was achieved by application of the multistage MS3 fragmentation 357➔325➔297. To verify the validity of this procedure, a systematic quantitative comparison of THCCOOH concentrations in hair with data from a well established GC-NCI-MS/MS technique was performed. Both techniques proved to be in good accordance (R(2)=0.647, p = <0.001) and equally suitable for hair testing of THCCOOH. Copyright © 2013 John Wiley & Sons, Ltd.

  11. Sensitivity improvement techniques for micromechanical vibrating accelerometers

    Directory of Open Access Journals (Sweden)

    Vtorushin Sergey

    2016-01-01

    Full Text Available The paper presents the problems of detecting a desired signal generated by micromechanical vibrating accelerometer. Three detection methods, namely frequency, amplitude and phase are considered in this paper. These methods are used in micromechanical vibrating accelerometers that incorporate a force sensitive element which transforms measured acceleration into the output signal. Investigations are carried out using the ANSYS finite element program and MATLAB/Simulink support package. Investigation results include the comparative analysis of the output signal characteristics obtained by the different detection methods.

  12. A highly sensitive hydrogen sensor with gas selectivity using a PMMA membrane-coated Pd nanoparticle/single-layer graphene hybrid.

    Science.gov (United States)

    Hong, Juree; Lee, Sanggeun; Seo, Jungmok; Pyo, Soonjae; Kim, Jongbaeg; Lee, Taeyoon

    2015-02-18

    A polymer membrane-coated palladium (Pd) nanoparticle (NP)/single-layer graphene (SLG) hybrid sensor was fabricated for highly sensitive hydrogen gas (H2) sensing with gas selectivity. Pd NPs were deposited on SLG via the galvanic displacement reaction between graphene-buffered copper (Cu) and Pd ion. During the galvanic displacement reaction, graphene was used as a buffer layer, which transports electrons from Cu for Pd to nucleate on the SLG surface. The deposited Pd NPs on the SLG surface were well-distributed with high uniformity and low defects. The Pd NP/SLG hybrid was then coated with polymer membrane layer for the selective filtration of H2. Because of the selective H2 filtration effect of the polymer membrane layer, the sensor had no responses to methane, carbon monoxide, or nitrogen dioxide gas. On the contrary, the PMMA/Pd NP/SLG hybrid sensor exhibited a good response to exposure to 2% H2: on average, 66.37% response within 1.81 min and recovery within 5.52 min. In addition, reliable and repeatable sensing behaviors were obtained when the sensor was exposed to different H2 concentrations ranging from 0.025 to 2%.

  13. Study of cavity effect in micro-Pirani gauge chamber with improved sensitivity for high vacuum regime

    Directory of Open Access Journals (Sweden)

    Guohe Zhang

    2018-05-01

    Full Text Available Ultra-low pressure application of Pirani gauge needs significant improvement of sensitivity and expansion of measureable low pressure limit. However, the performance of Pirani gauge in high vacuum regime remains critical concerns since gaseous thermal conduction with high percentage is essential requirement. In this work, the heat transfer mechanism of micro-Pirani gauge packaged in a non-hermetic chamber was investigated and analyzed compared with the one before wafer-level packaging. The cavity effect, extremely important for the efficient detection of low pressure, was numerically and experimentally analyzed considering the influence of the pressure, the temperature and the effective heat transfer area in micro-Pirani gauge chamber. The thermal conduction model is validated by experiment data of MEMS Pirani gauges with and without capping. It is found that nature gaseous convection in chamber, determined by the Rayleigh number, should be taken into consideration. The experiment and model calculated results show that thermal resistance increases in the molecule regime, and further increases after capping due to the suppression of gaseous convection. The gaseous thermal conduction accounts for an increasing percentage of thermal conduction at low pressure while little changes at high pressure after capping because of the existence of cavity effect improving the sensitivity of cavity-effect-influenced Pirani gauge for high vacuum regime.

  14. Genomic selection: genome-wide prediction in plant improvement.

    Science.gov (United States)

    Desta, Zeratsion Abera; Ortiz, Rodomiro

    2014-09-01

    Association analysis is used to measure relations between markers and quantitative trait loci (QTL). Their estimation ignores genes with small effects that trigger underpinning quantitative traits. By contrast, genome-wide selection estimates marker effects across the whole genome on the target population based on a prediction model developed in the training population (TP). Whole-genome prediction models estimate all marker effects in all loci and capture small QTL effects. Here, we review several genomic selection (GS) models with respect to both the prediction accuracy and genetic gain from selection. Phenotypic selection or marker-assisted breeding protocols can be replaced by selection, based on whole-genome predictions in which phenotyping updates the model to build up the prediction accuracy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Vantage sensitivity: a framework for individual differences in response to psychological intervention.

    Science.gov (United States)

    de Villiers, Bernadette; Lionetti, Francesca; Pluess, Michael

    2018-06-01

    People differ significantly in their response to psychological intervention, with some benefitting more from treatment than others. According to the recently proposed theoretical framework of vantage sensitivity, some of this variability may be due to individual differences in environmental sensitivity, the inherent ability to register, and process external stimuli. In this paper, we apply the vantage sensitivity framework to the field of psychiatry and clinical psychology, proposing that some people are more responsive to the positive effects of psychological intervention due to heightened sensitivity. After presenting theoretical frameworks related to environmental sensitivity, we review a selection of recent studies reporting individual differences in the positive response to psychological intervention. A growing number of studies report that some people benefit more from psychological intervention than others as a function of genetic, physiological, and psychological characteristics. These studies support the vantage sensitivity proposition that treatment response is influenced by factors associated with heightened sensitivity to environmental influences. More recently, studies have also shown that sensitivity can be measured with a short questionnaire which appears to predict the response to psychological intervention. Vantage sensitivity is a framework with significant relevance for our understanding of widely observed heterogeneity in treatment response. It suggests that variability in response to treatment is partly influenced by people's differing capacity for environmental sensitivity, which can be measured with a short questionnaire. Application of the vantage sensitivity framework to psychiatry and clinical psychology may improve our knowledge regarding when, how, and for whom interventions work.

  16. Pyridoxylamine reactivity kinetics as an amine based nucleophile for screening electrophilic dermal sensitizers

    Science.gov (United States)

    Chipinda, Itai; Mbiya, Wilbes; Adigun, Risikat Ajibola; Morakinyo, Moshood K.; Law, Brandon F.; Simoyi, Reuben H.; Siegel, Paul D.

    2015-01-01

    Chemical allergens bind directly, or after metabolic or abiotic activation, to endogenous proteins to become allergenic. Assessment of this initial binding has been suggested as a target for development of assays to screen chemicals for their allergenic potential. Recently we reported a nitrobenzenethiol (NBT) based method for screening thiol reactive skin sensitizers, however, amine selective sensitizers are not detected by this assay. In the present study we describe an amine (pyridoxylamine (PDA)) based kinetic assay to complement the NBT assay for identification of amine-selective and non-selective skin sensitizers. UV-Vis spectrophotometry and fluorescence were used to measure PDA reactivity for 57 chemicals including anhydrides, aldehydes, and quinones where reaction rates ranged from 116 to 6.2 × 10−6 M−1 s−1 for extreme to weak sensitizers, respectively. No reactivity towards PDA was observed with the thiol-selective sensitizers, non-sensitizers and prohaptens. The PDA rate constants correlated significantly with their respective murine local lymph node assay (LLNA) threshold EC3 values (R2 = 0.76). The use of PDA serves as a simple, inexpensive amine based method that shows promise as a preliminary screening tool for electrophilic, amine-selective skin sensitizers. PMID:24333919

  17. Sensitivity of Glacier Mass Balance Estimates to the Selection of WRF Cloud Microphysics Parameterization in the Indus River Watershed

    Science.gov (United States)

    Johnson, E. S.; Rupper, S.; Steenburgh, W. J.; Strong, C.; Kochanski, A.

    2017-12-01

    Climate model outputs are often used as inputs to glacier energy and mass balance models, which are essential glaciological tools for testing glacier sensitivity, providing mass balance estimates in regions with little glaciological data, and providing a means to model future changes. Climate model outputs, however, are sensitive to the choice of physical parameterizations, such as those for cloud microphysics, land-surface schemes, surface layer options, etc. Furthermore, glacier mass balance (MB) estimates that use these climate model outputs as inputs are likely sensitive to the specific parameterization schemes, but this sensitivity has not been carefully assessed. Here we evaluate the sensitivity of glacier MB estimates across the Indus Basin to the selection of cloud microphysics parameterizations in the Weather Research and Forecasting Model (WRF). Cloud microphysics parameterizations differ in how they specify the size distributions of hydrometeors, the rate of graupel and snow production, their fall speed assumptions, the rates at which they convert from one hydrometeor type to the other, etc. While glacier MB estimates are likely sensitive to other parameterizations in WRF, our preliminary results suggest that glacier MB is highly sensitive to the timing, frequency, and amount of snowfall, which is influenced by the cloud microphysics parameterization. To this end, the Indus Basin is an ideal study site, as it has both westerly (winter) and monsoonal (summer) precipitation influences, is a data-sparse region (so models are critical), and still has lingering questions as to glacier importance for local and regional resources. WRF is run at a 4 km grid scale using two commonly used parameterizations: the Thompson scheme and the Goddard scheme. On average, these parameterizations result in minimal differences in annual precipitation. However, localized regions exhibit differences in precipitation of up to 3 m w.e. a-1. The different schemes also impact the

  18. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.

    2016-03-30

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid-phase extraction (MISPE) polymer. The polymers were functionalized on an interdigital capacitive sensor for selective binding of phthalate molecules from a complex mixture of chemicals. Both polymers owned predetermined selectivity by formation of valuable molecular recognition sites for Bis (2-ethylhexyl) phthalate (DEHP). Polymers were immobilized on planar electrochemical sensor fabricated on a single crystal silicon substrate with 500 nm sputtered gold electrodes fabricated using MEMS fabrication techniques. Impedance spectra were obtained using electrochemical impedance spectroscopy (EIS) to determine sample conductance for evaluation of phthalate concentration in the spiked sample solutions with various phthalate concentrations. Experimental results revealed that the ability of SPME polymer to adsorb target molecules on the sensing surface is better than that of MISPE polymer for phthalates in the sensing system. Testing the extracted samples using high performance liquid chromatography with photodiode array detectors validated the results.

  19. Improving axion detection sensitivity in high purity germanium detector based experiments

    Science.gov (United States)

    Xu, Wenqin; Elliott, Steven

    2015-04-01

    Thanks to their excellent energy resolution and low energy threshold, high purity germanium (HPGe) crystals are widely used in low background experiments searching for neutrinoless double beta decay, e.g. the MAJORANA DEMONSTRATOR and the GERDA experiments, and low mass dark matter, e.g. the CDMS and the EDELWEISS experiments. A particularly interesting candidate for low mass dark matter is the axion, which arises from the Peccei-Quinn solution to the strong CP problem and has been searched for in many experiments. Due to axion-photon coupling, the postulated solar axions could coherently convert to photons via the Primakeoff effect in periodic crystal lattices, such as those found in HPGe crystals. The conversion rate depends on the angle between axions and crystal lattices, so the knowledge of HPGe crystal axis is important. In this talk, we will present our efforts to improve the HPGe experimental sensitivity to axions by considering the axis orientations in multiple HPGe crystals simultaneously. We acknowledge the support of the U.S. Department of Energy through the LANL/LDRD Program.

  20. Detection of Independent Associations of Plasma Lipidomic Parameters with Insulin Sensitivity Indices Using Data Mining Methodology.

    Directory of Open Access Journals (Sweden)

    Steffi Kopprasch

    Full Text Available Glucolipotoxicity is a major pathophysiological mechanism in the development of insulin resistance and type 2 diabetes mellitus (T2D. We aimed to detect subtle changes in the circulating lipid profile by shotgun lipidomics analyses and to associate them with four different insulin sensitivity indices.The cross-sectional study comprised 90 men with a broad range of insulin sensitivity including normal glucose tolerance (NGT, n = 33, impaired glucose tolerance (IGT, n = 32 and newly detected T2D (n = 25. Prior to oral glucose challenge plasma was obtained and quantitatively analyzed for 198 lipid molecular species from 13 different lipid classes including triacylglycerls (TAGs, phosphatidylcholine plasmalogen/ether (PC O-s, sphingomyelins (SMs, and lysophosphatidylcholines (LPCs. To identify a lipidomic signature of individual insulin sensitivity we applied three data mining approaches, namely least absolute shrinkage and selection operator (LASSO, Support Vector Regression (SVR and Random Forests (RF for the following insulin sensitivity indices: homeostasis model of insulin resistance (HOMA-IR, glucose insulin sensitivity index (GSI, insulin sensitivity index (ISI, and disposition index (DI. The LASSO procedure offers a high prediction accuracy and and an easier interpretability than SVR and RF.After LASSO selection, the plasma lipidome explained 3% (DI to maximal 53% (HOMA-IR variability of the sensitivity indexes. Among the lipid species with the highest positive LASSO regression coefficient were TAG 54:2 (HOMA-IR, PC O- 32:0 (GSI, and SM 40:3:1 (ISI. The highest negative regression coefficient was obtained for LPC 22:5 (HOMA-IR, TAG 51:1 (GSI, and TAG 58:6 (ISI.Although a substantial part of lipid molecular species showed a significant correlation with insulin sensitivity indices we were able to identify a limited number of lipid metabolites of particular importance based on the LASSO approach. These few selected lipids with the closest

  1. Aegeline inspired synthesis of novel β3-AR agonist improves insulin sensitivity in vitro and in vivo models of insulin resistance.

    Science.gov (United States)

    Rajan, Sujith; Satish, Sabbu; Shankar, Kripa; Pandeti, Sukanya; Varshney, Salil; Srivastava, Ankita; Kumar, Durgesh; Gupta, Abhishek; Gupta, Sanchita; Choudhary, Rakhi; Balaramnavar, Vishal M; Narender, Tadigoppula; Gaikwad, Anil N

    2018-03-07

    In our drug discovery program of natural product, earlier we have reported Aegeline that is N-acylated-1-amino-2- alcohol, which was isolated from the leaves of Aeglemarmelos showed anti-hyperlipidemic activity for which the QSAR studies predicted the compound to be the β3-AR agonist, but the mechanism of its action was not elucidated. In our present study, we have evaluated the β3-AR activity of novel N-acyl-1-amino-3-arylopropanol synthetic mimics of aegeline and its beneficial effect in insulin resistance. In this study, we have proposed the novel pharmacophore model using reported molecules for antihyperlipidemic activity. The reported pharmacophore features were also compared with the newly developed pharmacophore model for the observed biological activity. Based on 3D pharmacophore modeling of known β3AR agonist, we screened 20 synthetic derivatives of Aegeline from the literature. From these, the top scoring compound 10C was used for further studies. The in-slico result was further validated in HEK293T cells co-trransfected with human β3-AR and CRE-Luciferase reporter plasmid for β3-AR activity.The most active compound was selected and β3-AR activity was further validated in white and brown adipocytes differentiated from human mesenchymal stem cells (hMSCs). Insulin resistance model developed in hMSC derived adipocytes was used to study the insulin sensitizing property. 8 week HFD fed C57BL6 mice was given 50 mg/Kg of the selected compound and metabolic phenotyping was done to evaluate its anti-diabetic effect. As predicted by in-silico 3D pharmacophore modeling, the compound 10C was found to be the most active and specific β3-AR agonist with EC 50 value of 447 nM. The compound 10C activated β3AR pathway, induced lipolysis, fatty acid oxidation and increased oxygen consumption rate (OCR) in human adipocytes. Compound 10C induced expression of brown adipocytes specific markers and reverted chronic insulin induced insulin resistance in white

  2. Mass hierarchy sensitivity of medium baseline reactor neutrino experiments with multiple detectors

    Directory of Open Access Journals (Sweden)

    Hong-Xin Wang

    2017-05-01

    Full Text Available We report the neutrino mass hierarchy (MH determination of medium baseline reactor neutrino experiments with multiple detectors, where the sensitivity of measuring the MH can be significantly improved by adding a near detector. Then the impact of the baseline and target mass of the near detector on the combined MH sensitivity has been studied thoroughly. The optimal selections of the baseline and target mass of the near detector are ∼12.5 km and ∼4 kton respectively for a far detector with the target mass of 20 kton and the baseline of 52.5 km. As typical examples of future medium baseline reactor neutrino experiments, the optimal location and target mass of the near detector are selected for the specific configurations of JUNO and RENO-50. Finally, we discuss distinct effects of the reactor antineutrino energy spectrum uncertainty for setups of a single detector and double detectors, which indicate that the spectrum uncertainty can be well constrained in the presence of the near detector.

  3. Two Dimensional Array of Piezoresistive Nanomechanical Membrane-Type Surface Stress Sensor (MSS with Improved Sensitivity

    Directory of Open Access Journals (Sweden)

    Nico F. de Rooij

    2012-11-01

    Full Text Available We present a new generation of piezoresistive nanomechanical Membrane-type Surface stress Sensor (MSS chips, which consist of a two dimensional array of MSS on a single chip. The implementation of several optimization techniques in the design and microfabrication improved the piezoresistive sensitivity by 3~4 times compared to the first generation MSS chip, resulting in a sensitivity about ~100 times better than a standard cantilever-type sensor and a few times better than optical read-out methods in terms of experimental signal-to-noise ratio. Since the integrated piezoresistive read-out of the MSS can meet practical requirements, such as compactness and not requiring bulky and expensive peripheral devices, the MSS is a promising transducer for nanomechanical sensing in the rapidly growing application fields in medicine, biology, security, and the environment. Specifically, its system compactness due to the integrated piezoresistive sensing makes the MSS concept attractive for the instruments used in mobile applications. In addition, the MSS can operate in opaque liquids, such as blood, where optical read-out techniques cannot be applied.

  4. Cermet based solar selective absorbers : further selectivity improvement and developing new fabrication technique

    OpenAIRE

    Nejati, Mohammadreza

    2008-01-01

    Spectral selectivity of cermet based selective absorbers were increased by inducing surface roughness on the surface of the cermet layer using a roughening technique (deposition on hot substrates) or by micro-structuring the metallic substrates before deposition of the absorber coating using laser and imprint structuring techniques. Cu-Al2O3 cermet absorbers with very rough surfaces and excellent selectivity were obtained by employing a roughness template layer under the infrared reflective l...

  5. The robust corrective action priority-an improved approach for selecting competing corrective actions in FMEA based on principle of robust design

    Science.gov (United States)

    Sutrisno, Agung; Gunawan, Indra; Vanany, Iwan

    2017-11-01

    In spite of being integral part in risk - based quality improvement effort, studies improving quality of selection of corrective action priority using FMEA technique are still limited in literature. If any, none is considering robustness and risk in selecting competing improvement initiatives. This study proposed a theoretical model to select risk - based competing corrective action by considering robustness and risk of competing corrective actions. We incorporated the principle of robust design in counting the preference score among corrective action candidates. Along with considering cost and benefit of competing corrective actions, we also incorporate the risk and robustness of corrective actions. An example is provided to represent the applicability of the proposed model.

  6. Synapsin Is Selectively Required for Anesthesia-Sensitive Memory

    Science.gov (United States)

    Knapek, Stephan; Gerber, Bertram; Tanimoto, Hiromu

    2010-01-01

    Odor-shock memory in "Drosophila melanogaster" consists of heterogeneous components each with different dynamics. We report that a null mutant for the evolutionarily conserved synaptic protein Synapsin entails a memory deficit selectively in early memory, leaving later memory as well as sensory motor function unaffected. Notably, a consolidated…

  7. Selected Problems of Sensitivity and Reliability of a Jack-Up Platform

    Directory of Open Access Journals (Sweden)

    Rozmarynowski Bogdan

    2018-03-01

    Full Text Available The paper deals with sensitivity and reliability applications to numerical studies of an off-shore platform model. Structural parameters and sea conditions are referred to the Baltic jack-up drilling platform. The sudy aims at the influence of particular basic variables on static and dynamic response as well as the probability of failure due to water waves and wind loads. The paper presents the sensitivity approach to a generalized eigenvalue problem and evaluation of the performace functions. The first order time-invariant problems of structural reliability analysis are under concern.

  8. Intensive insulin therapy improves insulin sensitivity and mitochondrial function in severely burned children.

    Science.gov (United States)

    Fram, Ricki Y; Cree, Melanie G; Wolfe, Robert R; Mlcak, Ronald P; Qian, Ting; Chinkes, David L; Herndon, David N

    2010-06-01

    To institute intensive insulin therapy protocol in an acute pediatric burn unit and study the mechanisms underlying its benefits. Prospective, randomized study. An acute pediatric burn unit in a tertiary teaching hospital. Children, 4-18 yrs old, with total body surface area burned > or =40% and who arrived within 1 wk after injury were enrolled in the study. Patients were randomized to one of two groups. Intensive insulin therapy maintained blood glucose levels between 80 and 110 mg/dL. Conventional insulin therapy maintained blood glucose patients were included in the data analysis consisting of resting energy expenditure, whole body and liver insulin sensitivity, and skeletal muscle mitochondrial function. Studies were performed at 7 days postburn (pretreatment) and at 21 days postburn (posttreatment). Resting energy expenditure significantly increased posttreatment (1476 +/- 124 to 1925 +/- 291 kcal/m(2) x day; p = .02) in conventional insulin therapy as compared with a decline in intensive insulin therapy. Glucose infusion rate was identical between groups before treatment (6.0 +/- 0.8 conventional insulin therapy vs. 6.8 +/- 0.9 mg/kg x min intensive insulin therapy; p = .5). Intensive insulin therapy displayed a significantly higher glucose clamp infusion rate posttreatment (9.1 +/- 1.3 intensive insulin therapy versus 4.8 +/- 0.6 mg/kg x min conventional insulin therapy, p = .005). Suppression of hepatic glucose release was significantly greater in the intensive insulin therapy after treatment compared with conventional insulin therapy (5.0 +/- 0.9 vs. 2.5 +/- 0.6 mg/kg x min; intensive insulin therapy vs. conventional insulin therapy; p = .03). States 3 and 4 mitochondrial oxidation of palmitate significantly improved in intensive insulin therapy (0.9 +/- 0.1 to 1.7 +/- 0.1 microm O(2)/CS/mg protein/min for state 3, p = .004; and 0.7 +/- 0.1 to 1.3 +/- 0.1 microm O(2)/CS/mg protein/min for state 4, p protocol improves insulin sensitivity and mitochondrial

  9. Improving the Sensitivity and Functionality of Mobile Webcam-Based Fluorescence Detectors for Point-of-Care Diagnostics in Global Health

    Science.gov (United States)

    Rasooly, Reuven; Bruck, Hugh Alan; Balsam, Joshua; Prickril, Ben; Ossandon, Miguel; Rasooly, Avraham

    2016-01-01

    Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be sufficiently affordable and portable for use in global health settings. Most current clinical optical imaging technologies are accurate and sensitive, but also expensive and difficult to adapt for use in these settings. These challenges can be mitigated by taking advantage of affordable consumer electronics mobile devices such as webcams, mobile phones, charge-coupled device (CCD) cameras, lasers, and LEDs. Low-cost, portable multi-wavelength fluorescence plate readers have been developed for many applications including detection of microbial toxins such as C. Botulinum A neurotoxin, Shiga toxin, and S. aureus enterotoxin B (SEB), and flow cytometry has been used to detect very low cell concentrations. However, the relatively low sensitivities of these devices limit their clinical utility. We have developed several approaches to improve their sensitivity presented here for webcam based fluorescence detectors, including (1) image stacking to improve signal-to-noise ratios; (2) lasers to enable fluorescence excitation for flow cytometry; and (3) streak imaging to capture the trajectory of a single cell, enabling imaging sensors with high noise levels to detect rare cell events. These approaches can also help to overcome some of the limitations of other low-cost optical detection technologies such as CCD or phone-based detectors (like high noise levels or low sensitivities), and provide for their use in low-cost medical diagnostics in resource-poor settings. PMID:27196933

  10. Improving the Sensitivity and Functionality of Mobile Webcam-Based Fluorescence Detectors for Point-of-Care Diagnostics in Global Health

    Directory of Open Access Journals (Sweden)

    Reuven Rasooly

    2016-05-01

    Full Text Available Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be sufficiently affordable and portable for use in global health settings. Most current clinical optical imaging technologies are accurate and sensitive, but also expensive and difficult to adapt for use in these settings. These challenges can be mitigated by taking advantage of affordable consumer electronics mobile devices such as webcams, mobile phones, charge-coupled device (CCD cameras, lasers, and LEDs. Low-cost, portable multi-wavelength fluorescence plate readers have been developed for many applications including detection of microbial toxins such as C. Botulinum A neurotoxin, Shiga toxin, and S. aureus enterotoxin B (SEB, and flow cytometry has been used to detect very low cell concentrations. However, the relatively low sensitivities of these devices limit their clinical utility. We have developed several approaches to improve their sensitivity presented here for webcam based fluorescence detectors, including (1 image stacking to improve signal-to-noise ratios; (2 lasers to enable fluorescence excitation for flow cytometry; and (3 streak imaging to capture the trajectory of a single cell, enabling imaging sensors with high noise levels to detect rare cell events. These approaches can also help to overcome some of the limitations of other low-cost optical detection technologies such as CCD or phone-based detectors (like high noise levels or low sensitivities, and provide for their use in low-cost medical diagnostics in resource-poor settings.

  11. Gut microbiota metabolites, amino acid metabolites and improvements in insulin sensitivity and glucose metabolism: the POUNDS Lost trial.

    Science.gov (United States)

    Heianza, Yoriko; Sun, Dianjianyi; Li, Xiang; DiDonato, Joseph A; Bray, George A; Sacks, Frank M; Qi, Lu

    2018-06-02

    Alterations in gut microbiota have been linked to host insulin resistance, diabetes and impaired amino acid metabolism. We investigated whether changes in gut microbiota-dependent metabolite of trimethylamine N-oxide (TMAO) and its nutrient precursors (choline and L-carnitine) were associated with improvements in glucose metabolism and diabetes-related amino acids in a weight-loss diet intervention. We included 504 overweight and obese adults who were randomly assigned to one of four energy-reduced diets varying in macronutrient intake. The 6-month changes (Δ) in TMAO, choline and L-carnitine levels after the intervention were calculated. Greater decreases in choline and L-carnitine were significantly (p<0.05) associated with greater improvements in fasting insulin concentrations and homeostasis model assessment of insulin resistance (HOMA-IR) at 6 months. The reduction of choline was significantly related to 2-year improvements in glucose and insulin resistance. We found significant linkages between dietary fat intake and ΔTMAO for changes in fasting glucose, insulin and HOMA-IR (p interaction <0.05); a greater increase in TMAO was related to lesser improvements in the outcomes among participants who consumed a high-fat diet. In addition, ΔL-carnitine and Δcholine were significantly related to changes in amino acids (including branched-chain and aromatic amino acids). Interestingly, the associations of ΔTMAO, Δcholine and ΔL-carnitine with diabetes-related traits were independent of the changes in amino acids. Our findings underscore the importance of changes in TMAO, choline and L-carnitine in improving insulin sensitivity during a weight-loss intervention for obese patients. Dietary fat intake may modify the associations of TMAO with insulin sensitivity and glucose metabolism. NCT00072995. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless

  12. Improved sensitivity to venom specific-immunoglobulin E by spiking with the allergen component in Japanese patients suspected of Hymenoptera venom allergy

    Directory of Open Access Journals (Sweden)

    Naruo Yoshida

    2015-07-01

    Conclusions: The measurement of sIgE following spiking of rVes v 5 and rPol d 5 by conventional testing in Japanese subjects with sIgE against hornet and paper wasp venom, respectively, improved the sensitivity for detecting Hymenoptera venom allergy. Improvement testing for measuring sIgE levels against hornet and paper wasp venom has potential for serologically elucidating Hymenoptera allergy in Japan.

  13. Inhibitory Control of Feature Selectivity in an Object Motion Sensitive Circuit of the Retina

    Directory of Open Access Journals (Sweden)

    Tahnbee Kim

    2017-05-01

    Full Text Available Object motion sensitive (OMS W3-retinal ganglion cells (W3-RGCs in mice respond to local movements in a visual scene but remain silent during self-generated global image motion. The excitatory inputs that drive responses of W3-RGCs to local motion were recently characterized, but which inhibitory neurons suppress W3-RGCs’ responses to global motion, how these neurons encode motion information, and how their connections are organized along the excitatory circuit axis remains unknown. Here, we find that a genetically identified amacrine cell (AC type, TH2-AC, exhibits fast responses to global motion and slow responses to local motion. Optogenetic stimulation shows that TH2-ACs provide strong GABAA receptor-mediated input to W3-RGCs but only weak input to upstream excitatory neurons. Cell-type-specific silencing reveals that temporally coded inhibition from TH2-ACs cancels W3-RGC spike responses to global but not local motion stimuli and, thus, controls the feature selectivity of OMS signals sent to the brain.

  14. Positive selection of a duplicated UV-sensitive visual pigment coincides with wing pigment evolution in Heliconius butterflies

    Science.gov (United States)

    Briscoe, Adriana D.; Bybee, Seth M.; Bernard, Gary D.; Yuan, Furong; Sison-Mangus, Marilou P.; Reed, Robert D.; Warren, Andrew D.; Llorente-Bousquets, Jorge; Chiao, Chuan-Chin

    2010-01-01

    The butterfly Heliconius erato can see from the UV to the red part of the light spectrum with color vision proven from 440 to 640 nm. Its eye is known to contain three visual pigments, rhodopsins, produced by an 11-cis-3-hydroxyretinal chromophore together with long wavelength (LWRh), blue (BRh) and UV (UVRh1) opsins. We now find that H. erato has a second UV opsin mRNA (UVRh2)—a previously undescribed duplication of this gene among Lepidoptera. To investigate its evolutionary origin, we screened eye cDNAs from 14 butterfly species in the subfamily Heliconiinae and found both copies only among Heliconius. Phylogeny-based tests of selection indicate positive selection of UVRh2 following duplication, and some of the positively selected sites correspond to vertebrate visual pigment spectral tuning residues. Epi-microspectrophotometry reveals two UV-absorbing rhodopsins in the H. erato eye with λmax = 355 nm and 398 nm. Along with the additional UV opsin, Heliconius have also evolved 3-hydroxy-DL-kynurenine (3-OHK)-based yellow wing pigments not found in close relatives. Visual models of how butterflies perceive wing color variation indicate this has resulted in an expansion of the number of distinguishable yellow colors on Heliconius wings. Functional diversification of the UV-sensitive visual pigments may help explain why the yellow wing pigments of Heliconius are so colorful in the UV range compared to the yellow pigments of close relatives lacking the UV opsin duplicate. PMID:20133601

  15. Medium chain fatty acids are selective peroxisome proliferator activated receptor (PPAR) γ activators and pan-PPAR partial agonists

    NARCIS (Netherlands)

    Liberato, Marcelo Vizoná; Nascimento, Alessandro S; Ayers, Steven D; Lin, Jean Z; Cvoro, Aleksandra; Silveira, Rodrigo L; Martínez, Leandro; Souza, Paulo C T; Saidemberg, Daniel; Deng, Tuo; Amato, Angela Angelica; Togashi, Marie; Hsueh, Willa A; Phillips, Kevin; Palma, Mário Sérgio; Neves, Francisco A R; Skaf, Munir S; Webb, Paul; Polikarpov, Igor

    2012-01-01

    Thiazolidinediones (TZDs) act through peroxisome proliferator activated receptor (PPAR) γ to increase insulin sensitivity in type 2 diabetes (T2DM), but deleterious effects of these ligands mean that selective modulators with improved clinical profiles are needed. We obtained a crystal structure of

  16. Entangled-Pair Transmission Improvement Using Distributed Phase-Sensitive Amplification

    Directory of Open Access Journals (Sweden)

    Anjali Agarwal

    2014-12-01

    Full Text Available We demonstrate the transmission of time-bin entangled photon pairs through a distributed optical phase-sensitive amplifier (OPSA. We utilize four-wave mixing at telecom wavelengths in a 5-km dispersion-shifted fiber OPSA operating in the low-gain limit. Measurements of two-photon interference curves show no statistically significant degradation in the fringe visibility at the output of the OPSA. In addition, coincidence counting rates are higher than direct passive transmission because of constructive interference between amplitudes of input photon pairs and those generated in the OPSA. Our results suggest that application of distributed phase-sensitive amplification to transmission of entangled photon pairs could be highly beneficial towards advancing the rate and scalability of future quantum communications systems.

  17. A Novel Experimental Set-Up for Improving the Sensitivity of SV Waves to Shallow Surface-Breaking Cracks

    Energy Technology Data Exchange (ETDEWEB)

    Pecorari, Claudio [Royal Inst. of Technology, Stockholm (Sweden). Dept. of Aeronautical and Vehicle Engineering

    2006-03-15

    Conventional inspection procedures to detect surface-breaking defects in train axels and thick pipes often employ 45-degree incidence shear vertical (SV) waves as probing tool. Recently obtained theoretical and experimental results indicate that this method is considerably less sensitivity to shallow surface-breaking defects, than the one in which the angle of incidence is selected to be close to the critical angle of the longitudinal wave. This project has confirmed this thesis by experimentally investigating the backscattering of SV waves by surface-breaking cracks as a function o t the angle of incidence. To this end, three cracks of depth approximately equal to 0.3 mm, 0.5 mm and 0.7 were introduced on the surface of steel samples with a thickness of 47 mm. These cracks were insonified with transducers operating at 2.25 MHz, 3.5 MHz, and 5 MHz, which correspond to wavelengths in steel of 1.38 mm, 0.88 mm, and 0.62 mm, respectively. The increase in sensitivity has been assessed in the order of 15 dB.

  18. Mannitol enhances antibiotic sensitivity of persister bacteria in Pseudomonas aeruginosa biofilms.

    Directory of Open Access Journals (Sweden)

    Nicolas Barraud

    Full Text Available The failure of antibiotic therapies to clear Pseudomonas aeruginosa lung infection, the key mortality factor for cystic fibrosis (CF patients, is partly attributed to the high tolerance of P. aeruginosa biofilms. Mannitol has previously been found to restore aminoglycoside sensitivity in Escherichia coli by generating a proton-motive force (PMF, suggesting a potential new strategy to improve antibiotic therapy and reduce disease progression in CF. Here, we used the commonly prescribed aminoglycoside tobramycin to select for P. aeruginosa persister cells during biofilm growth. Incubation with mannitol (10-40 mM increased tobramycin sensitivity of persister cells up to 1,000-fold. Addition of mannitol to pre-grown biofilms was able to revert the persister phenotype and improve the efficacy of tobramycin. This effect was blocked by the addition of a PMF inhibitor or in a P. aeruginosa mutant strain unable to metabolise mannitol. Addition of glucose and NaCl at high osmolarity also improved the efficacy of tobramycin although to a lesser extent compared to mannitol. Therefore, the primary effect of mannitol in reverting biofilm associated persister cells appears to be an active, physiological response, associated with a minor contribution of osmotic stress. Mannitol was tested against clinically relevant strains, showing that biofilms containing a subpopulation of persister cells are better killed in the presence of mannitol, but a clinical strain with a high resistance to tobramycin was not affected by mannitol. Overall, these results suggest that in addition to improvements in lung function by facilitating mucus clearance in CF, mannitol also affects antibiotic sensitivity in biofilms and does so through an active, physiological response.

  19. Possibilities to improve sensitivity and rendering of detail of streamer chamber track photographs

    Energy Technology Data Exchange (ETDEWEB)

    Baehr, J

    1975-01-01

    Streamer chambers are increasingly used as effective particle detectors in the field of experimental elementary particle physics. The photographic recording of high energy events in streamer chambers is limited by performance of current photographic silver-halide layers. Similar limiting problems occur in other fields as well, e.g., in astronomy, x-ray medicine and photogrammetry; therefore methods have been developed to increase sensitivity and improve the information transfer of the emulsion. In this paper these methods have been classified and summarized under the aspect of their application to streamer image recording. Proposals for further investigations are given. Especially the applicability of these methods, their possibility of combination to large film lengths should be investigated The detective quantum efficiency (DQE) is proposed as criterion to estimate and compare the different methods.

  20. A modified Janus cassette (Sweet Janus to improve allelic replacement efficiency by high-stringency negative selection in Streptococcus pneumoniae.

    Directory of Open Access Journals (Sweden)

    Yuan Li

    Full Text Available The Janus cassette permits marker-free allelic replacement or knockout in streptomycin-resistant Streptococcus pneumoniae (pneumococcus through sequential positive and negative selection. Spontaneous revertants of Janus can lead to high level of false-positives during negative selection, which necessitate a time-consuming post-selection screening process. We hypothesized that an additional counter-selectable marker in Janus would decrease the revertant frequency and reduce false-positives, since simultaneous reversion of both counter-selectable makers is much less likely. Here we report a modified cassette, Sweet Janus (SJ, in which the sacB gene from Bacillus subtilis conferring sucrose sensitivity is added to Janus. By using streptomycin and sucrose simultaneously as selective agents, the frequency of SJ double revertants was about 105-fold lower than the frequency of Janus revertants. Accordingly, the frequency of false-positives in the SJ-mediated negative selection was about 100-fold lower than what was seen for Janus. Thus, SJ enhances negative selection stringency and can accelerate allelic replacement in pneumococcus, especially when transformation frequency is low due to strain background or suboptimal transformation conditions. Results also suggested the sacB gene alone can function as a counter-selectable marker in the Gram-positive pneumococcus, which will have the advantage of not requiring a streptomycin-resistant strain for allelic replacement.

  1. Capillary Isotachophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring MS via a Novel Sheathless Interface for High Sensitivity Sample Quantification

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chenchen (Chloe); Lee, Cheng S.; Smith, Richard D.; Tang, Keqi

    2013-06-21

    A novel sheathless CITP/CZE-MS interface featuring a large i.d. separation capillary and a detachable small i.d. ESI emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantitation (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with excellent measurement reproducibility were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.

  2. Mono(pyridine-N-oxide) analog of DOTA as a suitable organic reagent for a sensitive and selective fluorimetric determination of Ln(III) ions

    Energy Technology Data Exchange (ETDEWEB)

    Vanek, Jakub [Department of Chemistry, Faculty of Science, Masaryk University, Kotlarska 2, 611 37 Brno (Czech Republic); Central European Institute of Technology (CEITEC), Masaryk University, Kamenice 5, 625 00 Brno (Czech Republic); Lubal, Premysl, E-mail: lubal@chemi.muni.cz [Department of Chemistry, Faculty of Science, Masaryk University, Kotlarska 2, 611 37 Brno (Czech Republic); Central European Institute of Technology (CEITEC), Masaryk University, Kamenice 5, 625 00 Brno (Czech Republic); Sevcikova, Romana [Department of Chemistry, Faculty of Science, Masaryk University, Kotlarska 2, 611 37 Brno (Czech Republic); Polasek, Miloslav; Hermann, Petr [Department of Inorganic Chemistry, Faculty of Science, Charles University, Hlavova 2030, 128 40, Prague (Czech Republic)

    2012-08-15

    The mono(pyridine-N-oxide) analog of the H{sub 4}dota macrocylic ligand, H{sub 3}do3a-py{sup NO}, is capable of forming thermodynamically stable and kinetically inert Ln(III) complexes. Its Eu(III) and Tb(III) complexes display a strong long-lived fluorescence as a result of the antenna effect of the pyridine-N-oxide fluorophore in the reagent. It is shown that H{sub 3}do3a-py{sup NO} can be used as a fluorogenic reagent for the determination of Eu(III) and Tb(III) at pH 6.5 and c{sub L}=1 mM. At an excitation wavelength of 286 nm, the emission maxima are 615 nm (Eu(III)-complex), and 547 nm (Tb(III)complex). Detection limits are at concentrations around 1.0 {mu}M and linearity of the method spans over 2 orders of magnitude. The method was applied to artificial and real samples (spiked mineral waters, extracts from cathode ray tube luminophore dust) and gave satisfactory results. The method is simple, rapid, and hardly interfered by other metal ions. - Graphical Abstract: A DOTA-like ligand with pyridine-N-oxide pendant arm is used for a quick, selective and sensitive determination of Eu{sup 3+} and Tb{sup 3+} ions through sensitized emission with excitation at 286 nm. The presented fluorimetric method is not interfered by transition metal or other lanthanide(III) ions and has a high dynamic range. Highlights: Black-Right-Pointing-Pointer Quick, selective and sensitive determination of Eu{sup 3+}/Tb{sup 3+} ions was developed. Black-Right-Pointing-Pointer Sensitized emission with excitation at 286 nm through pyridine-N-oxide pendant arm. Black-Right-Pointing-Pointer No interference of transition metal or other Ln(III) ions within high dynamic range.

  3. Specificity and sensitivity assessment of selected nasal provocation testing techniques

    Directory of Open Access Journals (Sweden)

    Edyta Krzych-Fałta

    2016-12-01

    Full Text Available Introduction: Nasal provocation testing involves an allergen-specific local reaction of the nasal mucosa to the administered allergen. Aim: To determine the most objective nasal occlusion assessment technique that could be used in nasal provocation testing. Material and methods : A total of 60 subjects, including 30 patients diagnosed with allergy to common environmental allergens and 30 healthy subjects were enrolled into the study. The method used in the study was a nasal provocation test with an allergen, with a standard dose of a control solution and an allergen (5,000 SBU/ml administered using a calibrated atomizer into both nostrils at room temperature. Early-phase nasal mucosa response in the early phase of the allergic reaction was assessed via acoustic rhinometry, optical rhinometry, nitric oxide in nasal air, and tryptase levels in the nasal lavage fluid. Results : In estimating the homogeneity of the average values, the Levene’s test was used and receiver operating characteristic curves were plotted for all the methods used for assessing the nasal provocation test with an allergen. Statistically significant results were defined for p < 0.05. Of all the objective assessment techniques, the most sensitive and characteristic ones were the optical rhinometry techniques (specificity = 1, sensitivity = 1, AUC = 1, PPV = 1, NPV = 1. Conclusions : The techniques used showed significant differences between the group of patients with allergic rhinitis and the control group. Of all the objective assessment techniques, those most sensitive and characteristic were the optical rhinometry.

  4. Highly sensitive and selective detection of dopamine using one-pot synthesized highly photoluminescent silicon nanoparticles.

    Science.gov (United States)

    Zhang, Xiaodong; Chen, Xiaokai; Kai, Siqi; Wang, Hong-Yin; Yang, Jingjing; Wu, Fu-Gen; Chen, Zhan

    2015-03-17

    A simple and highly efficient method for dopamine (DA) detection using water-soluble silicon nanoparticles (SiNPs) was reported. The SiNPs with a high quantum yield of 23.6% were synthesized by using a one-pot microwave-assisted method. The fluorescence quenching capability of a variety of molecules on the synthesized SiNPs has been tested; only DA molecules were found to be able to quench the fluorescence of these SiNPs effectively. Therefore, such a quenching effect can be used to selectively detect DA. All other molecules tested have little interference with the dopamine detection, including ascorbic acid, which commonly exists in cells and can possibly affect the dopamine detection. The ratio of the fluorescence intensity difference between the quenched and unquenched cases versus the fluorescence intensity without quenching (ΔI/I) was observed to be linearly proportional to the DA analyte concentration in the range from 0.005 to 10.0 μM, with a detection limit of 0.3 nM (S/N = 3). To the best of our knowledge, this is the lowest limit for DA detection reported so far. The mechanism of fluorescence quenching is attributed to the energy transfer from the SiNPs to the oxidized dopamine molecules through Förster resonance energy transfer. The reported method of SiNP synthesis is very simple and cheap, making the above sensitive and selective DA detection approach using SiNPs practical for many applications.

  5. A TOTAL MANUFACTURING SOLUTIONS TECHNIQUE TO SELECT APPROPRIATE IMPROVEMENT STRATEGY: CASE STUDY OF A FOOTWEAR FACTORY

    Directory of Open Access Journals (Sweden)

    Gezahegn Tesfaye

    2014-09-01

    Full Text Available The Government of Ethiopia is promoting the manufacturing sector to join the global market in a large scale. Due to its comparative advantages, the Ethiopian leather and leather products industry have been given due attention. To fully utilize such advantages, the country shifted its export items from hides/skins to footwear products. Nevertheless, the performance of the leather sector in general and footwear sub-sector in particular is far below the desired standards. The improvement strategies applied hitherto were mainly to tackle a small portion of their total problems. If the Ethiopian footwear companies have to become globally competitive, their entire business spectrum has to be assessed and appropriate improvement strategies must be selected. In this research, we used a Total manufacturing solutions (TMS technique to identify areas of improvement and improvement strategy of one of Ethiopian footwear companies. For this purpose, we conducted two surveys using structured questionnaire. The first survey was to test the TMS technique against the context of footwear industry. The result proved that the original TMS model can be used to measure the performance of footwear companies. The second survey was done to identify company's total problems, map its current position and select appropriate improvement strategy. The result revealed that the company has company-wide problems and its current position is a plodder. For plodders which have company-wide problems, the improvement strategy must include aggressive application of BPR; and the implementation of best practices to develop workers skills that encourages networking and promotion, a market-led manufacturing strategy, employee involvement and team work cultures. According to the findings of this research, we suggested that a BPR technique followed by a continuous improvement programme could be an appropriate improvement strategy for this company. The company requires long-term improvement

  6. Graphene–platinum nanocomposite as a sensitive and selective voltammetric sensor for trace level arsenic quantification

    Directory of Open Access Journals (Sweden)

    R. Kempegowda

    2014-01-01

    Full Text Available A simple protocol for the chemical modification of graphene with platinum nanoparticles and its subsequent electroanalytical application toward sensitive and selective determination of arsenic has been described. Chemical modification was carried out by the simultaneous and sequential chemical reduction of graphene oxide and hexachloroplatinic acid in the presence of ethylene glycol as a mild reducing agent. The synthesized graphene–platinum nanocomposite (Gr–nPt has been characterized through infrared spectroscopy, x-ray diffraction study, field emission scanning electron microscopy and cyclic voltammetry (CV techniques. CV and square-wave anodic stripping voltammetry have been used to quantify arsenic. The proposed nanostructure showed linearity in the concentration range 10–100 nM with a detection limit of 1.1 nM. The proposed sensor has been successfully applied to measure trace levels of arsenic present in natural sample matrices like borewell water, polluted lake water, agricultural soil, tomato and spinach leaves.

  7. Wind power forecast using wavelet neural network trained by improved Clonal selection algorithm

    International Nuclear Information System (INIS)

    Chitsaz, Hamed; Amjady, Nima; Zareipour, Hamidreza

    2015-01-01

    Highlights: • Presenting a Morlet wavelet neural network for wind power forecasting. • Proposing improved Clonal selection algorithm for training the model. • Applying Maximum Correntropy Criterion to evaluate the training performance. • Extensive testing of the proposed wind power forecast method on real-world data. - Abstract: With the integration of wind farms into electric power grids, an accurate wind power prediction is becoming increasingly important for the operation of these power plants. In this paper, a new forecasting engine for wind power prediction is proposed. The proposed engine has the structure of Wavelet Neural Network (WNN) with the activation functions of the hidden neurons constructed based on multi-dimensional Morlet wavelets. This forecast engine is trained by a new improved Clonal selection algorithm, which optimizes the free parameters of the WNN for wind power prediction. Furthermore, Maximum Correntropy Criterion (MCC) has been utilized instead of Mean Squared Error as the error measure in training phase of the forecasting model. The proposed wind power forecaster is tested with real-world hourly data of system level wind power generation in Alberta, Canada. In order to demonstrate the efficiency of the proposed method, it is compared with several other wind power forecast techniques. The obtained results confirm the validity of the developed approach

  8. Prediction of Skin Sensitization with a Particle Swarm Optimized Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Chenzhong Cao

    2009-07-01

    Full Text Available Skin sensitization is the most commonly reported occupational illness, causing much suffering to a wide range of people. Identification and labeling of environmental allergens is urgently required to protect people from skin sensitization. The guinea pig maximization test (GPMT and murine local lymph node assay (LLNA are the two most important in vivo models for identification of skin sensitizers. In order to reduce the number of animal tests, quantitative structure-activity relationships (QSARs are strongly encouraged in the assessment of skin sensitization of chemicals. This paper has investigated the skin sensitization potential of 162 compounds with LLNA results and 92 compounds with GPMT results using a support vector machine. A particle swarm optimization algorithm was implemented for feature selection from a large number of molecular descriptors calculated by Dragon. For the LLNA data set, the classification accuracies are 95.37% and 88.89% for the training and the test sets, respectively. For the GPMT data set, the classification accuracies are 91.80% and 90.32% for the training and the test sets, respectively. The classification performances were greatly improved compared to those reported in the literature, indicating that the support vector machine optimized by particle swarm in this paper is competent for the identification of skin sensitizers.

  9. Prediction of Skin Sensitization with a Particle Swarm Optimized Support Vector Machine

    Science.gov (United States)

    Yuan, Hua; Huang, Jianping; Cao, Chenzhong

    2009-01-01

    Skin sensitization is the most commonly reported occupational illness, causing much suffering to a wide range of people. Identification and labeling of environmental allergens is urgently required to protect people from skin sensitization. The guinea pig maximization test (GPMT) and murine local lymph node assay (LLNA) are the two most important in vivo models for identification of skin sensitizers. In order to reduce the number of animal tests, quantitative structure-activity relationships (QSARs) are strongly encouraged in the assessment of skin sensitization of chemicals. This paper has investigated the skin sensitization potential of 162 compounds with LLNA results and 92 compounds with GPMT results using a support vector machine. A particle swarm optimization algorithm was implemented for feature selection from a large number of molecular descriptors calculated by Dragon. For the LLNA data set, the classification accuracies are 95.37% and 88.89% for the training and the test sets, respectively. For the GPMT data set, the classification accuracies are 91.80% and 90.32% for the training and the test sets, respectively. The classification performances were greatly improved compared to those reported in the literature, indicating that the support vector machine optimized by particle swarm in this paper is competent for the identification of skin sensitizers. PMID:19742136

  10. FDG-PET improves the staging and selection of patients with recurrent colorectal cancer

    International Nuclear Information System (INIS)

    Lonneux, Max; Reffad, Abdel-Malek; Pauwels, Stanislas; Detry, Roger; Kartheuser, Alex; Gigot, Jean-Francois

    2002-01-01

    Whole-body fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) has proved effective in the diagnosis and staging of recurrent colorectal cancer. In this study, we analysed how PET affects the management of patients with recurrent colorectal cancer by permitting more accurate selection of candidates for curative resection. The data of 79 patients with known or suspected recurrent colorectal cancer were analysed. Conventional imaging modalities (CIM) and PET results were compared with regard to their accuracy in determining the extent and the resectability of tumour recurrence. Recurrence was demonstrated in 68 of the 79 patients. The data indicate that PET was superior to CIM for detection of recurrence at all sites except the liver. Based on the CIM+PET staging, surgery with curative intent was proposed in 39 patients and was indeed achieved in 31 of them (80%). PET was more accurate than CIM alone in predicting the resectability or non-resectability of the recurrence (82% vs 68%, P=0.02). It is concluded that whole-body FDG-PET is highly sensitive for both the diagnosis and the staging of patients with recurrent colorectal cancer. Its use in conjunction with conventional imaging procedures results in a more accurate selection of patients for surgical treatment with curative intent. (orig.)

  11. Working memory load can both improve and impair selective attention: evidence from the Navon paradigm.

    Science.gov (United States)

    Ahmed, Lubna; de Fockert, Jan W

    2012-10-01

    Selective attention to relevant targets has been shown to depend on the availability of working memory (WM). Under conditions of high WM load, processing of irrelevant distractors is enhanced. Here we showed that this detrimental effect of WM load on selective attention efficiency is reversed when the task requires global- rather than local-level processing. Participants were asked to attend to either the local or the global level of a hierarchical Navon stimulus while keeping either a low or a high load in WM. In line with previous findings, during attention to the local level, distractors at the global level produced more interference under high than under low WM load. By contrast, loading WM had the opposite effect of improving selective attention during attention to the global level. The findings demonstrate that the impact of WM load on selective attention is not invariant, but rather is dependent on the level of the to-be-attended information.

  12. Sensitivity and response time improvements in millimeter-wave spectrometers

    International Nuclear Information System (INIS)

    Kolbe, W.F.; Leskovar, B.

    1980-09-01

    A new version of a microwave spectrometer for the detection of gaseous pollutants and other atmospheric constituents is described. The spectrometer, which operates in the vicinity of 70 GHz, employs a Fabry-Perot resonator as a sample cell and uses superhetrodyne detection for high sensitivity. The spectrometer has been modified to incorporate a frequency doubler modulated at 30 MHz to permit operation with a single Gunn oscillator source. As a result, faster response time and somewhat greater sensitivity are obtained. The spectrometer is capable of detecting a minimum concentration of 1 ppM of SO 2 diluted in air with a 1 second time constant. For OCS diluted in air, the minimum detectable concentration is 800 ppB and with a 10 second time constant 300 ppB

  13. Unique proteomic signature for radiation sensitive patients; a comparative study between normo-sensitive and radiation sensitive breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Skiöld, Sara [Center for Radiation Protection Research, Department of Molecular Biosciences, The Wernner-Gren Institute, Stockholm University, Stockholm (Sweden); Azimzadeh, Omid [Institute of Radiation Biology, German Research Center for Environmental Health, Helmholtz Zentrum München (Germany); Merl-Pham, Juliane [Research Unit Protein Science, German Research Center for Environmental Health, Helmholtz Zentrum München, Neuherberg (Germany); Naslund, Ingemar; Wersall, Peter; Lidbrink, Elisabet [Division of Radiotherapy, Radiumhemmet, Karolinska University Hospital, Stockholm (Sweden); Tapio, Soile [Institute of Radiation Biology, German Research Center for Environmental Health, Helmholtz Zentrum München (Germany); Harms-Ringdahl, Mats [Center for Radiation Protection Research, Department of Molecular Biosciences, The Wernner-Gren Institute, Stockholm University, Stockholm (Sweden); Haghdoost, Siamak, E-mail: Siamak.Haghdoost@su.se [Center for Radiation Protection Research, Department of Molecular Biosciences, The Wernner-Gren Institute, Stockholm University, Stockholm (Sweden)

    2015-06-15

    Highlights: • The unique protein expression profiles were found that separate radiosensitive from normal sensitive breast cancer patients. • The oxidative stress response, coagulation properties and acute phase response suggested to be the hallmarks of radiation sensitivity. - Abstract: Radiation therapy is a cornerstone of modern cancer treatment. Understanding the mechanisms behind normal tissue sensitivity is essential in order to minimize adverse side effects and yet to prevent local cancer reoccurrence. The aim of this study was to identify biomarkers of radiation sensitivity to enable personalized cancer treatment. To investigate the mechanisms behind radiation sensitivity a pilot study was made where eight radiation-sensitive and nine normo-sensitive patients were selected from a cohort of 2914 breast cancer patients, based on acute tissue reactions after radiation therapy. Whole blood was sampled and irradiated in vitro with 0, 1, or 150 mGy followed by 3 h incubation at 37 °C. The leukocytes of the two groups were isolated, pooled and protein expression profiles were investigated using isotope-coded protein labeling method (ICPL). First, leukocytes from the in vitro irradiated whole blood from normo-sensitive and extremely sensitive patients were compared to the non-irradiated controls. To validate this first study a second ICPL analysis comparing only the non-irradiated samples was conducted. Both approaches showed unique proteomic signatures separating the two groups at the basal level and after doses of 1 and 150 mGy. Pathway analyses of both proteomic approaches suggest that oxidative stress response, coagulation properties and acute phase response are hallmarks of radiation sensitivity supporting our previous study on oxidative stress response. This investigation provides unique characteristics of radiation sensitivity essential for individualized radiation therapy.

  14. Unique proteomic signature for radiation sensitive patients; a comparative study between normo-sensitive and radiation sensitive breast cancer patients

    International Nuclear Information System (INIS)

    Skiöld, Sara; Azimzadeh, Omid; Merl-Pham, Juliane; Naslund, Ingemar; Wersall, Peter; Lidbrink, Elisabet; Tapio, Soile; Harms-Ringdahl, Mats; Haghdoost, Siamak

    2015-01-01

    Highlights: • The unique protein expression profiles were found that separate radiosensitive from normal sensitive breast cancer patients. • The oxidative stress response, coagulation properties and acute phase response suggested to be the hallmarks of radiation sensitivity. - Abstract: Radiation therapy is a cornerstone of modern cancer treatment. Understanding the mechanisms behind normal tissue sensitivity is essential in order to minimize adverse side effects and yet to prevent local cancer reoccurrence. The aim of this study was to identify biomarkers of radiation sensitivity to enable personalized cancer treatment. To investigate the mechanisms behind radiation sensitivity a pilot study was made where eight radiation-sensitive and nine normo-sensitive patients were selected from a cohort of 2914 breast cancer patients, based on acute tissue reactions after radiation therapy. Whole blood was sampled and irradiated in vitro with 0, 1, or 150 mGy followed by 3 h incubation at 37 °C. The leukocytes of the two groups were isolated, pooled and protein expression profiles were investigated using isotope-coded protein labeling method (ICPL). First, leukocytes from the in vitro irradiated whole blood from normo-sensitive and extremely sensitive patients were compared to the non-irradiated controls. To validate this first study a second ICPL analysis comparing only the non-irradiated samples was conducted. Both approaches showed unique proteomic signatures separating the two groups at the basal level and after doses of 1 and 150 mGy. Pathway analyses of both proteomic approaches suggest that oxidative stress response, coagulation properties and acute phase response are hallmarks of radiation sensitivity supporting our previous study on oxidative stress response. This investigation provides unique characteristics of radiation sensitivity essential for individualized radiation therapy

  15. Improvements in absolute seismometer sensitivity calibration using local earth gravity measurements

    Science.gov (United States)

    Anthony, Robert E.; Ringler, Adam; Wilson, David

    2018-01-01

    The ability to determine both absolute and relative seismic amplitudes is fundamentally limited by the accuracy and precision with which scientists are able to calibrate seismometer sensitivities and characterize their response. Currently, across the Global Seismic Network (GSN), errors in midband sensitivity exceed 3% at the 95% confidence interval and are the least‐constrained response parameter in seismic recording systems. We explore a new methodology utilizing precise absolute Earth gravity measurements to determine the midband sensitivity of seismic instruments. We first determine the absolute sensitivity of Kinemetrics EpiSensor accelerometers to 0.06% at the 99% confidence interval by inverting them in a known gravity field at the Albuquerque Seismological Laboratory (ASL). After the accelerometer is calibrated, we install it in its normal configuration next to broadband seismometers and subject the sensors to identical ground motions to perform relative calibrations of the broadband sensors. Using this technique, we are able to determine the absolute midband sensitivity of the vertical components of Nanometrics Trillium Compact seismometers to within 0.11% and Streckeisen STS‐2 seismometers to within 0.14% at the 99% confidence interval. The technique enables absolute calibrations from first principles that are traceable to National Institute of Standards and Technology (NIST) measurements while providing nearly an order of magnitude more precision than step‐table calibrations.

  16. Improving the Quality of Recycled Fine Aggregate by Selective Removal of Brittle Defects

    OpenAIRE

    Ogawa, Hideo; Nawa, Toyoharu

    2012-01-01

    Crushed recycled aggregate contains particles with brittle defects such as cracks, pores, and voids. This study presents a method for improving the quality of recycled fine aggregate by selectively removing these defects. Fourteen recycled fine aggregates were manufactured by three types of processors including a jaw crusher, ball mill, and granulator. The influence of the recycled fine aggregate on the flowability and strength of the mortar was evaluated by multivariate analysis. The results...

  17. Toward selective, sensitive, and discriminative detection of Hg(2+) and Cd(2+)via pH-modulated surface chemistry of glutathione-capped gold nanoclusters.

    Science.gov (United States)

    Huang, Pengcheng; Li, Sha; Gao, Nan; Wu, Fangying

    2015-11-07

    Heavy metal pollution can exert severe effects on the environment and human health. Simple, selective, and sensitive detection of heavy metal ions, especially two or more, using a single probe, is thereby of great importance. In this study, we report a new and facile strategy for discriminative detection of Hg(2+) and Cd(2+) with high selectivity and sensitivity via pH-modulated surface chemistry of the glutathione-capped gold NCs (GSH-Au NCs). By simply adjusting pH values of the colloidal solution of the NCs, Hg(2+) could specifically turn off the fluorescence under acidic pH, however, Cd(2+) could exclusively turn on the fluorescence under alkaline pH. This enables the NCs to serve as a dual fluorescent sensor for Hg(2+) and Cd(2+). We demonstrate that these two opposing sensing modes are presumably due to different interaction mechanisms: Hg(2+) induces aggregation by dissociating GSH from the Au surface via robust coordination and, Cd(2+) could passivate the Au surface by forming a Cd-GSH complex with a compact structure. Finally, the present strategy is successfully exploited to separately determine Hg(2+) and Cd(2+) in environmental water samples.

  18. Anodal transcranial direct current stimulation transiently improves contrast sensitivity and normalizes visual cortex activation in individuals with amblyopia.

    Science.gov (United States)

    Spiegel, Daniel P; Byblow, Winston D; Hess, Robert F; Thompson, Benjamin

    2013-10-01

    Amblyopia is a neurodevelopmental disorder of vision that is associated with abnormal patterns of neural inhibition within the visual cortex. This disorder is often considered to be untreatable in adulthood because of insufficient visual cortex plasticity. There is increasing evidence that interventions that target inhibitory interactions within the visual cortex, including certain types of noninvasive brain stimulation, can improve visual function in adults with amblyopia. We tested the hypothesis that anodal transcranial direct current stimulation (a-tDCS) would improve visual function in adults with amblyopia by enhancing the neural response to inputs from the amblyopic eye. Thirteen adults with amblyopia participated and contrast sensitivity in the amblyopic and fellow fixing eye was assessed before, during and after a-tDCS or cathodal tDCS (c-tDCS). Five participants also completed a functional magnetic resonance imaging (fMRI) study designed to investigate the effect of a-tDCS on the blood oxygen level-dependent response within the visual cortex to inputs from the amblyopic versus the fellow fixing eye. A subgroup of 8/13 participants showed a transient improvement in amblyopic eye contrast sensitivity for at least 30 minutes after a-tDCS. fMRI measurements indicated that the characteristic cortical response asymmetry in amblyopes, which favors the fellow eye, was reduced by a-tDCS. These preliminary results suggest that a-tDCS deserves further investigation as a potential tool to enhance amblyopia treatment outcomes in adults.

  19. Prediction of clamp-derived insulin sensitivity from the oral glucose insulin sensitivity index

    DEFF Research Database (Denmark)

    Tura, Andrea; Chemello, Gaetano; Szendroedi, Julia

    2018-01-01

    that underwent both a clamp and an OGTT or meal test, thereby allowing calculation of both the M value and OGIS. The population was divided into a training and a validation cohort (n = 359 and n = 154, respectively). After a stepwise selection approach, the best model for M value prediction was applied......AIMS/HYPOTHESIS: The euglycaemic-hyperinsulinaemic clamp is the gold-standard method for measuring insulin sensitivity, but is less suitable for large clinical trials. Thus, several indices have been developed for evaluating insulin sensitivity from the oral glucose tolerance test (OGTT). However......, most of them yield values different from those obtained by the clamp method. The aim of this study was to develop a new index to predict clamp-derived insulin sensitivity (M value) from the OGTT-derived oral glucose insulin sensitivity index (OGIS). METHODS: We analysed datasets of people...

  20. Spatial attention enhances the selective integration of activity from area MT.

    Science.gov (United States)

    Masse, Nicolas Y; Herrington, Todd M; Cook, Erik P

    2012-09-01

    Distinguishing which of the many proposed neural mechanisms of spatial attention actually underlies behavioral improvements in visually guided tasks has been difficult. One attractive hypothesis is that attention allows downstream neural circuits to selectively integrate responses from the most informative sensory neurons. This would allow behavioral performance to be based on the highest-quality signals available in visual cortex. We examined this hypothesis by asking how spatial attention affects both the stimulus sensitivity of middle temporal (MT) neurons and their corresponding correlation with behavior. Analyzing a data set pooled from two experiments involving four monkeys, we found that spatial attention did not appreciably affect either the stimulus sensitivity of the neurons or the correlation between their activity and behavior. However, for those sessions in which there was a robust behavioral effect of attention, focusing attention inside the neuron's receptive field significantly increased the correlation between these two metrics, an indication of selective integration. These results suggest that, similar to mechanisms proposed for the neural basis of perceptual learning, the behavioral benefits of focusing spatial attention are attributable to selective integration of neural activity from visual cortical areas by their downstream targets.